Sample records for measurements study protocol

  1. Measurement properties of maximal cardiopulmonary exercise tests protocols in persons after stroke: A systematic review.

    PubMed

    Wittink, Harriet; Verschuren, Olaf; Terwee, Caroline; de Groot, Janke; Kwakkel, Gert; van de Port, Ingrid

    2017-11-21

    To systematically review and critically appraise the literature on measurement properties of cardiopulmonary exercise test protocols for measuring aerobic capacity, VO2max, in persons after stroke. PubMed, Embase and Cinahl were searched from inception up to 15 June 2016. A total of 9 studies were identified reporting on 9 different cardiopulmonary exercise test protocols. VO2max measured with cardiopulmonary exercise test and open spirometry was the construct of interest. The target population was adult persons after stroke. We included all studies that evaluated reliability, measurement error, criterion validity, content validity, hypothesis testing and/or responsiveness of cardiopulmonary exercise test protocols. Two researchers independently screened the literature, assessed methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments checklist and extracted data on measurement properties of cardiopulmonary exercise test protocols. Most studies reported on only one measurement property. Best-evidence synthesis was derived taking into account the methodological quality of the studies, the results and the consistency of the results. No judgement could be made on which protocol is "best" for measuring VO2max in persons after stroke due to lack of high-quality studies on the measurement properties of the cardiopulmonary exercise test.

  2. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 4; Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, J. L. (Editor); Fargion, Giuletta S. (Editor); McClain, Charles R. (Editor); Pegau, Scott; Zaneveld, J. Ronald V.; Mitchell, B. Gregg; Kahru, Mati; Wieland, John; Stramska, Malgorzat

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

  3. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4, Volume IV: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols

    NASA Technical Reports Server (NTRS)

    Mueller, J. L.; Fargion, G. S.; McClain, C. R. (Editor); Pegau, S.; Zanefeld, J. R. V.; Mitchell, B. G.; Kahru, M.; Wieland, J.; Stramska, M.

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.

  4. Fixation and Commitment while Designing and Its Measurement

    ERIC Educational Resources Information Center

    Gero, John S.

    2011-01-01

    This paper introduces the notion that fixation and commitment while designing can be measured by studying the protocol of the design session. It is hypothesized that the dynamic entropy of the linkograph of the protocol provides the basis for such a measurement. The hypothesis is empirically tested using a design protocol and the results…

  5. Comparison of protocols measuring diffusion and partition coefficients in the stratum corneum

    PubMed Central

    Rothe, H.; Obringer, C.; Manwaring, J.; Avci, C.; Wargniez, W.; Eilstein, J.; Hewitt, N.; Cubberley, R.; Duplan, H.; Lange, D.; Jacques‐Jamin, C.; Klaric, M.; Schepky, A.

    2017-01-01

    Abstract Partition (K) and diffusion (D) coefficients are important to measure for the modelling of skin penetration of chemicals through the stratum corneum (SC). We compared the feasibility of three protocols for the testing of 50 chemicals in our main studies, using three cosmetics‐relevant model chemicals with a wide range of logP values. Protocol 1: SC concentration‐depth profile using tape‐stripping (measures KSC/v and DSC/HSC 2, where HSC is the SC thickness); Protocol 2A: incubation of isolated SC with chemical (direct measurement of KSC/v only) and Protocol 2B: diffusion through isolated SC mounted on a Franz cell (measures KSC/v and DSC/HSC 2, and is based on Fick's laws). KSC/v values for caffeine and resorcinol using Protocol 1 and 2B were within 30% of each other, values using Protocol 2A were ~two‐fold higher, and all values were within 10‐fold of each other. Only indirect determination of KSC/v by Protocol 2B was different from the direct measurement of KSC/v by Protocol 2A and Protocol 1 for 7‐EC. The variability of KSC/v for all three chemicals using Protocol 2B was higher compared to Protocol 1 and 2A. DSC/HSC 2 values for the three chemicals were of the same order of magnitude using all three protocols. Additionally, using Protocol 1, there was very little difference between parameters measured in pig and human SC. In conclusion, KSC/v, and DSC values were comparable using different methods. Pig skin might be a good surrogate for human skin for the three chemicals tested. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd. PMID:28139006

  6. Differences in handgrip strength protocols to identify sarcopenia and frailty - a systematic review.

    PubMed

    Sousa-Santos, A R; Amaral, T F

    2017-10-16

    Hand grip strength (HGS) is used for the diagnosis of sarcopenia and frailty. Several factors have been shown to influence HGS values during measurement. Therefore, variations in the protocols used to assess HGS, as part of the diagnosis of sarcopenia and frailty, may lead to the identification of different individuals with low HGS, introducing bias. The aim of this systematic review is to gather all the relevant studies that measured HGS to diagnose sarcopenia and frailty and to identify the differences between the protocols used. A systematic review was carried out following the recommendations of The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Statement. PubMed and Web of Science were systematically searched, until August 16, 2016. The evidence regarding HGS measurement protocols used to diagnose sarcopenia and frailty was summarised and the most recent protocols regarding the procedure were compared. From the described search 4393 articles were identified. Seventy-two studies were included in this systematic review, in which 37 referred to sarcopenia articles, 33 to frailty and two evaluated both conditions. Most studies presented limited information regarding the protocols used. The majority of the studies included did not describe a complete procedure of HGS measurement. The high heterogeneity between the protocols used, in sarcopenia and frailty studies, create an enormous difficulty in drawing comparative conclusions among them.

  7. Treatment influencing down-staging in EORTC Melanoma Group sentinel node histological protocol compared with complete step-sectioning: a national multicentre study.

    PubMed

    Riber-Hansen, Rikke; Hastrup, Nina; Clemmensen, Ole; Behrendt, Nille; Klausen, Siri; Ramsing, Mette; Spaun, Eva; Hamilton-Dutoit, Stephen Jacques; Steiniche, Torben

    2012-02-01

    Metastasis size in melanoma sentinel lymph nodes (SLNs) is an emerging prognostic factor. Two European melanoma treatment trials include SLN metastasis diameters as inclusion criteria. Whilst diameter estimates are sensitive to the number of sections examined, the level of this bias is largely unknown. We performed a prospective multicentre study to compare the European Organisation for Research and Treatment of Cancer (EORTC) recommended protocol with a protocol of complete step-sectioning. One hundred and thirty-three consecutive SLNs from seven SLN centres were analysed by five central sections 50μm apart (EORTC Protocol) followed by complete 250μm step-sectioning. Overall, 29 patients (21.8%) were SLN-positive. The EORTC Protocol missed eight of these metastases (28%), one metastasis measuring less than 0.1mm in diameter, seven measuring between 0.1 and 1mm. Complete step-sectioning at 250μm intervals (Extensive Protocol) missed one metastasis (3%) that measured less than 0.1mm. Thirteen treatment courses (34%) performed if inclusion was based on the Combined Protocol would not be performed if assessed by the EORTC Protocol. Thus, 10 patients would be without completion lymph node dissection (EORTC MINITUB study), whilst three patients would not be eligible for anti-CTLA4 trial (EORTC protocol 18071). The corresponding number with the Extensive Protocol would be three; one patient for the MINITUB registration study and two patients for the anti-CTLA4 study. Examining SLNs by close central sectioning alone (EORTC Protocol) misses a substantial number of metastases and underestimates the maximum metastasis diameter, leading to important changes in patient eligibility for various treatment protocols. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 6; Special Topics in Ocean Optics Protocols and Appendices; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, J. L. (Editor); Fargion, Giulietta S. (Editor); McClain, Charles R. (Editor)

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

  9. Intra-protocol repeatability and inter-protocol agreement for the analysis of scapulo-humeral coordination.

    PubMed

    Parel, I; Cutti, A G; Kraszewski, A; Verni, G; Hillstrom, H; Kontaxis, A

    2014-03-01

    Multi-center clinical trials incorporating shoulder kinematics are currently uncommon. The absence of repeatability and limits of agreement (LoA) studies between different centers employing different motion analysis protocols has led to a lack dataset compatibility. Therefore, the aim of this work was to determine the repeatability and LoA between two shoulder kinematic protocols. The first one uses a scapula tracker (ST), the International Society of Biomechanics anatomical frames and an optoelectronic measurement system, and the second uses a spine tracker, the INAIL Shoulder and Elbow Outpatient protocol (ISEO) and an inertial and magnetic measurement system. First within-protocol repeatability for each approach was assessed on a group of 23 healthy subjects and compared with the literature. Then, the between-protocol agreement was evaluated. The within-protocol repeatability was similar for the ST ([Formula: see text] = 2.35°, [Formula: see text] = 0.97°, SEM = 2.5°) and ISEO ([Formula: see text] = 2.24°, [Formula: see text] = 0.97°, SEM = 2.3°) protocols and comparable with data from published literature. The between-protocol agreement analysis showed comparable scapula medio-lateral rotation measurements for up to 120° of flexion-extension and up to 100° of scapula plane ab-adduction. Scapula protraction-retraction measurements were in agreement for a smaller range of humeral elevation. The results of this study suggest comparable repeatability for the ST and ISEO protocols and between-protocol agreement for two scapula rotations. Different thresholds for repeatability and LoA may be adapted to suit different clinical hypotheses.

  10. Sequence optimization to reduce velocity offsets in cardiovascular magnetic resonance volume flow quantification - A multi-vendor study

    PubMed Central

    2011-01-01

    Purpose Eddy current induced velocity offsets are of concern for accuracy in cardiovascular magnetic resonance (CMR) volume flow quantification. However, currently known theoretical aspects of eddy current behavior have not led to effective guidelines for the optimization of flow quantification sequences. This study is aimed at identifying correlations between protocol parameters and the resulting velocity error in clinical CMR flow measurements in a multi-vendor study. Methods Nine 1.5T scanners of three different types/vendors were studied. Measurements were performed on a large stationary phantom. Starting from a clinical breath-hold flow protocol, several protocol parameters were varied. Acquisitions were made in three clinically relevant orientations. Additionally, a time delay between the bipolar gradient and read-out, asymmetric versus symmetric velocity encoding, and gradient amplitude and slew rate were studied in adapted sequences as exploratory measurements beyond the protocol. Image analysis determined the worst-case offset for a typical great-vessel flow measurement. Results The results showed a great variation in offset behavior among scanners (standard deviation among samples of 0.3, 0.4, and 0.9 cm/s for the three different scanner types), even for small changes in the protocol. Considering the absolute values, none of the tested protocol settings consistently reduced the velocity offsets below the critical level of 0.6 cm/s neither for all three orientations nor for all three scanner types. Using multilevel linear model analysis, oblique aortic and pulmonary slices showed systematic higher offsets than the transverse aortic slices (oblique aortic 0.6 cm/s, and pulmonary 1.8 cm/s higher than transverse aortic). The exploratory measurements beyond the protocol yielded some new leads for further sequence development towards reduction of velocity offsets; however those protocols were not always compatible with the time-constraints of breath-hold imaging and flow-related artefacts. Conclusions This study showed that with current systems there was no generic protocol which resulted into acceptable flow offset values. Protocol optimization would have to be performed on a per scanner and per protocol basis. Proper optimization might make accurate (transverse) aortic flow quantification possible for most scanners. Pulmonary flow quantification would still need further (offline) correction. PMID:21388521

  11. Comparison of protocols measuring diffusion and partition coefficients in the stratum corneum.

    PubMed

    Rothe, H; Obringer, C; Manwaring, J; Avci, C; Wargniez, W; Eilstein, J; Hewitt, N; Cubberley, R; Duplan, H; Lange, D; Jacques-Jamin, C; Klaric, M; Schepky, A; Grégoire, S

    2017-07-01

    Partition (K) and diffusion (D) coefficients are important to measure for the modelling of skin penetration of chemicals through the stratum corneum (SC). We compared the feasibility of three protocols for the testing of 50 chemicals in our main studies, using three cosmetics-relevant model chemicals with a wide range of logP values. Protocol 1: SC concentration-depth profile using tape-stripping (measures K SC/v and D SC /H SC 2 , where H SC is the SC thickness); Protocol 2A: incubation of isolated SC with chemical (direct measurement of K SC/v only) and Protocol 2B: diffusion through isolated SC mounted on a Franz cell (measures K SC/v and D SC /H SC 2 , and is based on Fick's laws). K SC/v values for caffeine and resorcinol using Protocol 1 and 2B were within 30% of each other, values using Protocol 2A were ~two-fold higher, and all values were within 10-fold of each other. Only indirect determination of K SC/v by Protocol 2B was different from the direct measurement of K SC/v by Protocol 2A and Protocol 1 for 7-EC. The variability of K SC/v for all three chemicals using Protocol 2B was higher compared to Protocol 1 and 2A. D SC /H SC 2 values for the three chemicals were of the same order of magnitude using all three protocols. Additionally, using Protocol 1, there was very little difference between parameters measured in pig and human SC. In conclusion, K SC/v, and D SC values were comparable using different methods. Pig skin might be a good surrogate for human skin for the three chemicals tested. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd.

  12. A comparison of protocols and observer precision for measuring physical stream attributes

    USGS Publications Warehouse

    Whitacre, H.W.; Roper, B.B.; Kershner, J.L.

    2007-01-01

    Stream monitoring programs commonly measure physical attributes to assess the effect of land management on stream habitat. Variability associated with the measurement of these attributes has been linked to a number of factors, but few studies have evaluated variability due to differences in protocols. We compared six protocols, five used by the U.S. Department of Agriculture Forest Service and one by the U.S. Environmental Protection Agency, on six streams in Oregon and Idaho to determine whether differences in protocol affect values for 10 physical stream attributes. Results from Oregon and Idaho were combined for groups participating in both states, with significant differences in attribute means for 9 out of the 10 stream attributes. Significant differences occurred in 5 of 10 in Idaho, and 10 of 10 in Oregon. Coefficients of variation, signal-to-noise ratio, and root mean square error were used to evaluate measurement precision. There were differences among protocols for all attributes when states were analyzed separately and as a combined dataset. Measurement differences were influenced by choice of instruments, measurement method, measurement location, attribute definitions, and training approach. Comparison of data gathered by observers using different protocols will be difficult unless a core set of protocols for commonly measured stream attributes can be standardized among monitoring programs.

  13. Deterministic generation of remote entanglement with active quantum feedback

    DOE PAGES

    Martin, Leigh; Motzoi, Felix; Li, Hanhan; ...

    2015-12-10

    We develop and study protocols for deterministic remote entanglement generation using quantum feedback, without relying on an entangling Hamiltonian. In order to formulate the most effective experimentally feasible protocol, we introduce the notion of average-sense locally optimal feedback protocols, which do not require real-time quantum state estimation, a difficult component of real-time quantum feedback control. We use this notion of optimality to construct two protocols that can deterministically create maximal entanglement: a semiclassical feedback protocol for low-efficiency measurements and a quantum feedback protocol for high-efficiency measurements. The latter reduces to direct feedback in the continuous-time limit, whose dynamics can bemore » modeled by a Wiseman-Milburn feedback master equation, which yields an analytic solution in the limit of unit measurement efficiency. Our formalism can smoothly interpolate between continuous-time and discrete-time descriptions of feedback dynamics and we exploit this feature to derive a superior hybrid protocol for arbitrary nonunit measurement efficiency that switches between quantum and semiclassical protocols. Lastly, we show using simulations incorporating experimental imperfections that deterministic entanglement of remote superconducting qubits may be achieved with current technology using the continuous-time feedback protocol alone.« less

  14. The impact of the Family Communication Coordinator (FCC) Protocol on the role stress of hospital chaplains.

    PubMed

    Dodd-McCue, Diane; Tartaglia, Alexander

    2005-01-01

    The Family Communication Coordinator (FCC) Protocol was implemented to provide early family intervention and to facilitate effective communications during potential organ donation cases. Previous studies found the Protocol associated with improved donor outcome measures and with reduced role stress for ICU nurses caring for potential donors. The present study examines the impact of the Protocol on the perceived role stress of hospital chaplains serving as FCCs. All hospital chaplains serving as FCCs at an academic teaching hospital were surveyed. Their perceptions of job dimensions, role stress, job satisfaction, and commitment were measured; interviews and secondary data supplemented the surveys. The findings demonstrate that the FCC Protocol is associated with improved role stress, specifically role ambiguity and role conflict, among hospital chaplains serving as FCCs. Additionally, the findings suggest that satisfaction with the Protocol may be associated with experience with the Protocol.

  15. Normalization of cortical thickness measurements across different T1 magnetic resonance imaging protocols by novel W-Score standardization.

    PubMed

    Chung, Jinyong; Yoo, Kwangsun; Lee, Peter; Kim, Chan Mi; Roh, Jee Hoon; Park, Ji Eun; Kim, Sang Joon; Seo, Sang Won; Shin, Jeong-Hyeon; Seong, Joon-Kyung; Jeong, Yong

    2017-10-01

    The use of different 3D T1-weighted magnetic resonance (T1 MR) imaging protocols induces image incompatibility across multicenter studies, negating the many advantages of multicenter studies. A few methods have been developed to address this problem, but significant image incompatibility still remains. Thus, we developed a novel and convenient method to improve image compatibility. W-score standardization creates quality reference values by using a healthy group to obtain normalized disease values. We developed a protocol-specific w-score standardization to control the protocol effect, which is applied to each protocol separately. We used three data sets. In dataset 1, brain T1 MR images of normal controls (NC) and patients with Alzheimer's disease (AD) from two centers, acquired with different T1 MR protocols, were used (Protocol 1 and 2, n = 45/group). In dataset 2, data from six subjects, who underwent MRI with two different protocols (Protocol 1 and 2), were used with different repetition times, echo times, and slice thicknesses. In dataset 3, T1 MR images from a large number of healthy normal controls (Protocol 1: n = 148, Protocol 2: n = 343) were collected for w-score standardization. The protocol effect and disease effect on subjects' cortical thickness were analyzed before and after the application of protocol-specific w-score standardization. As expected, different protocols resulted in differing cortical thickness measurements in both NC and AD subjects. Different measurements were obtained for the same subject when imaged with different protocols. Multivariate pattern difference between measurements was observed between the protocols. Classification accuracy between two protocols was nearly 90%. After applying protocol-specific w-score standardization, the differences between the protocols substantially decreased. Most importantly, protocol-specific w-score standardization reduced both univariate and multivariate differences in the images while maintaining the AD disease effect. Compared to conventional regression methods, our method showed the best performance for in terms of controlling the protocol effect while preserving disease information. Protocol-specific w-score standardization effectively resolved the concerns of conventional regression methods. It showed the best performance for improving the compatibility of a T1 MR post-processed feature, cortical thickness. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. On entropy change measurements around first order phase transitions in caloric materials.

    PubMed

    Caron, Luana; Ba Doan, Nguyen; Ranno, Laurent

    2017-02-22

    In this work we discuss the measurement protocols for indirect determination of the isothermal entropy change associated with first order phase transitions in caloric materials. The magneto-structural phase transitions giving rise to giant magnetocaloric effects in Cu-doped MnAs and FeRh are used as case studies to exemplify how badly designed protocols may affect isothermal measurements and lead to incorrect entropy change estimations. Isothermal measurement protocols which allow correct assessment of the entropy change around first order phase transitions in both direct and inverse cases are presented.

  17. Using generalizability theory to develop clinical assessment protocols.

    PubMed

    Preuss, Richard A

    2013-04-01

    Clinical assessment protocols must produce data that are reliable, with a clinically attainable minimal detectable change (MDC). In a reliability study, generalizability theory has 2 advantages over classical test theory. These advantages provide information that allows assessment protocols to be adjusted to match individual patient profiles. First, generalizability theory allows the user to simultaneously consider multiple sources of measurement error variance (facets). Second, it allows the user to generalize the findings of the main study across the different study facets and to recalculate the reliability and MDC based on different combinations of facet conditions. In doing so, clinical assessment protocols can be chosen based on minimizing the number of measures that must be taken to achieve a realistic MDC, using repeated measures to minimize the MDC, or simply based on the combination that best allows the clinician to monitor an individual patient's progress over a specified period of time.

  18. In-shoe plantar pressure measurements for the evaluation and adaptation of foot orthoses in patients with rheumatoid arthritis: A proof of concept study.

    PubMed

    Tenten-Diepenmaat, Marloes; Dekker, Joost; Steenbergen, Menno; Huybrechts, Elleke; Roorda, Leo D; van Schaardenburg, Dirkjan; Bus, Sicco A; van der Leeden, Marike

    2016-03-01

    Improving foot orthoses (FOs) in patients with rheumatoid arthritis (RA) by using in-shoe plantar pressure measurements seems promising. The objectives of this study were to evaluate (1) the outcome on plantar pressure distribution of FOs that were adapted using in-shoe plantar pressure measurements according to a protocol and (2) the protocol feasibility. Forty-five RA patients with foot problems were included in this observational proof-of concept study. FOs were custom-made by a podiatrist according to usual care. Regions of Interest (ROIs) for plantar pressure reduction were selected. According to a protocol, usual care FOs were evaluated using in-shoe plantar pressure measurements and, if necessary, adapted. Plantar pressure-time integrals at the ROIs were compared between the following conditions: (1) no-FO versus usual care FO and (2) usual care FO versus adapted FO. Semi-structured interviews were held with patients and podiatrists to evaluate the feasibility of the protocol. Adapted FOs were developed in 70% of the patients. In these patients, usual care FOs showed a mean 9% reduction in pressure-time integral at forefoot ROIs compared to no-FOs (p=0.01). FO adaptation led to an additional mean 3% reduction in pressure-time integral (p=0.05). The protocol was considered feasible by patients. Podiatrists considered the protocol more useful to achieve individual rather than general treatment goals. A final protocol was proposed. Using in-shoe plantar pressure measurements for adapting foot orthoses for patients with RA leads to a small additional plantar pressure reduction in the forefoot. Further research on the clinical relevance of this outcome is required. Copyright © 2016. Published by Elsevier B.V.

  19. Quantum fluctuation theorems and generalized measurements during the force protocol.

    PubMed

    Watanabe, Gentaro; Venkatesh, B Prasanna; Talkner, Peter; Campisi, Michele; Hänggi, Peter

    2014-03-01

    Generalized measurements of an observable performed on a quantum system during a force protocol are investigated and conditions that guarantee the validity of the Jarzynski equality and the Crooks relation are formulated. In agreement with previous studies by M. Campisi, P. Talkner, and P. Hänggi [Phys. Rev. Lett. 105, 140601 (2010); Phys. Rev. E 83, 041114 (2011)], we find that these fluctuation relations are satisfied for projective measurements; however, for generalized measurements special conditions on the operators determining the measurements need to be met. For the Jarzynski equality to hold, the measurement operators of the forward protocol must be normalized in a particular way. The Crooks relation additionally entails that the backward and forward measurement operators depend on each other. Yet, quite some freedom is left as to how the two sets of operators are interrelated. This ambiguity is removed if one considers selective measurements, which are specified by a joint probability density function of work and measurement results of the considered observable. We find that the respective forward and backward joint probabilities satisfy the Crooks relation only if the measurement operators of the forward and backward protocols are the time-reversed adjoints of each other. In this case, the work probability density function conditioned on the measurement result satisfies a modified Crooks relation. The modification appears as a protocol-dependent factor that can be expressed by the information gained by the measurements during the forward and backward protocols. Finally, detailed fluctuation theorems with an arbitrary number of intervening measurements are obtained.

  20. Quantification of the overall measurement uncertainty associated with the passive moss biomonitoring technique: Sample collection and processing.

    PubMed

    Aboal, J R; Boquete, M T; Carballeira, A; Casanova, A; Debén, S; Fernández, J A

    2017-05-01

    In this study we examined 6080 data gathered by our research group during more than 20 years of research on the moss biomonitoring technique, in order to quantify the variability generated by different aspects of the protocol and to calculate the overall measurement uncertainty associated with the technique. The median variance of the concentrations of different pollutants measured in moss tissues attributed to the different methodological aspects was high, reaching values of 2851 (ng·g -1 ) 2 for Cd (sample treatment), 35.1 (μg·g -1 ) 2 for Cu (sample treatment), 861.7 (ng·g -1 ) 2 and for Hg (material selection). These variances correspond to standard deviations that constitute 67, 126 and 59% the regional background levels of these elements in the study region. The overall measurement uncertainty associated with the worst experimental protocol (5 subsamples, refrigerated, washed, 5 × 5 m size of the sampling area and once a year sampling) was between 2 and 6 times higher than that associated with the optimal protocol (30 subsamples, dried, unwashed, 20 × 20 m size of the sampling area and once a week sampling), and between 1.5 and 7 times higher than that associated with the standardized protocol (30 subsamples and once a year sampling). The overall measurement uncertainty associated with the standardized protocol could generate variations of between 14 and 47% in the regional background levels of Cd, Cu, Hg, Pb and Zn in the study area and much higher levels of variation in polluted sampling sites. We demonstrated that although the overall measurement uncertainty of the technique is still high, it can be reduced by using already well defined aspects of the protocol. Further standardization of the protocol together with application of the information on the overall measurement uncertainty would improve the reliability and comparability of the results of different biomonitoring studies, thus extending use of the technique beyond the context of scientific research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques

    PubMed Central

    Deshpande, Sudesh; Dhote, Deepak; Thakur, Kalpna; Pawar, Amol; Kumar, Rajesh; Kumar, Munish; Kulkarni, M. S.; Sharma, S. D.; Kannan, V.

    2016-01-01

    The objective of this work was to measure patient eye lens dose for different cone-beam computed tomography (CBCT) acquisition protocols of Varian's On-Board Imaging (OBI) system using optically stimulated luminescence dosimeter (OSLD) and to study the variation in eye lens dose with patient geometry and distance of isocenter to the eye lens. During the experimental measurements, OSLD was placed on the patient between the eyebrows of both eyes in line of nose during CBCT image acquisition to measure eye lens doses. The eye lens dose measurements were carried out for three different cone-beam acquisition protocols (standard dose head, low-dose head [LDH], and high-quality head [HQH]) of Varian OBI. Measured doses were correlated with patient geometry and distance between isocenter and eye lens. Measured eye lens doses for standard head and HQH protocols were in the range of 1.8–3.2 mGy and 4.5–9.9 mGy, respectively. However, the measured eye lens dose for the LDH protocol was in the range of 0.3–0.7 mGy. The measured data indicate that eye lens dose to patient depends on the selected imaging protocol. It was also observed that eye lens dose does not depend on patient geometry but strongly depends on distance between eye lens and treatment field isocenter. However, undoubted advantages of imaging system should not be counterbalanced by inappropriate selection of imaging protocol, especially for very intense imaging protocol. PMID:27651564

  2. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Revised

    NASA Technical Reports Server (NTRS)

    Fargion, Giulietta S.; Mueller, James L.

    2000-01-01

    The document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. This document supersedes the earlier version (Mueller and Austin 1995) published as Volume 25 in the SeaWiFS Technical Report Series. This document marks a significant departure from, and improvement on, theformat and content of Mueller and Austin (1995). The authorship of the protocols has been greatly broadened to include experts specializing in some key areas. New chapters have been added to provide detailed and comprehensive protocols for stability monitoring of radiometers using portable sources, abovewater measurements of remote-sensing reflectance, spectral absorption measurements for discrete water samples, HPLC pigment analysis and fluorometric pigment analysis. Protocols were included in Mueller and Austin (1995) for each of these areas, but the new treatment makes significant advances in each topic area. There are also new chapters prescribing protocols for calibration of sun photometers and sky radiance sensors, sun photometer and sky radiance measurements and analysis, and data archival. These topic areas were barely mentioned in Mueller and Austin (1995).

  3. Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT?

    PubMed

    Ho, Lisa M; Nelson, Rendon C; Delong, David M

    2007-05-01

    To prospectively evaluate the use of lean body weight (LBW) as the main determinant of the volume and rate of contrast material administration during multi-detector row computed tomography of the liver. This HIPAA-compliant study had institutional review board approval. All patients gave written informed consent. Four protocols were compared. Standard protocol involved 125 mL of iopamidol injected at 4 mL/sec. Total body weight (TBW) protocol involved 0.7 g iodine per kilogram of TBW. Calculated LBW and measured LBW protocols involved 0.86 g of iodine per kilogram and 0.92 g of iodine per kilogram calculated or measured LBW for men and women, respectively. Injection rate used for the three experimental protocols was determined proportionally on the basis of the calculated volume of contrast material. Postcontrast attenuation measurements during portal venous phase were obtained in liver, portal vein, and aorta for each group and were summed for each patient. Patient-to-patient enhancement variability in same group was measured with Levene test. Two-tailed t test was used to compare the three experimental protocols with the standard protocol. Data analysis was performed in 101 patients (25 or 26 patients per group), including 56 men and 45 women (mean age, 53 years). Average summed attenuation values for standard, TBW, calculated LBW, and measured LBW protocols were 419 HU +/- 50 (standard deviation), 443 HU +/- 51, 433 HU +/- 50, and 426 HU +/- 33, respectively (P = not significant for all). Levene test results for summed attenuation data for standard, TBW, calculated LBW, and measured LBW protocols were 40 +/- 29, 38 +/- 33 (P = .83), 35 +/- 35 (P = .56), and 26 +/- 19 (P = .05), respectively. By excluding highly variable but poorly perfused adipose tissue from calculation of contrast medium dose, the measured LBW protocol may lessen patient-to-patient enhancement variability while maintaining satisfactory hepatic and vascular enhancement.

  4. Quantum fluctuation theorems and generalized measurements during the force protocol

    NASA Astrophysics Data System (ADS)

    Watanabe, Gentaro; Venkatesh, B. Prasanna; Talkner, Peter; Campisi, Michele; Hänggi, Peter

    2014-03-01

    Generalized measurements of an observable performed on a quantum system during a force protocol are investigated and conditions that guarantee the validity of the Jarzynski equality and the Crooks relation are formulated. In agreement with previous studies by M. Campisi, P. Talkner, and P. Hänggi [Phys. Rev. Lett. 105, 140601 (2010), 10.1103/PhysRevLett.105.140601; Phys. Rev. E 83, 041114 (2011), 10.1103/PhysRevE.83.041114], we find that these fluctuation relations are satisfied for projective measurements; however, for generalized measurements special conditions on the operators determining the measurements need to be met. For the Jarzynski equality to hold, the measurement operators of the forward protocol must be normalized in a particular way. The Crooks relation additionally entails that the backward and forward measurement operators depend on each other. Yet, quite some freedom is left as to how the two sets of operators are interrelated. This ambiguity is removed if one considers selective measurements, which are specified by a joint probability density function of work and measurement results of the considered observable. We find that the respective forward and backward joint probabilities satisfy the Crooks relation only if the measurement operators of the forward and backward protocols are the time-reversed adjoints of each other. In this case, the work probability density function conditioned on the measurement result satisfies a modified Crooks relation. The modification appears as a protocol-dependent factor that can be expressed by the information gained by the measurements during the forward and backward protocols. Finally, detailed fluctuation theorems with an arbitrary number of intervening measurements are obtained.

  5. Validity of linear measurements of the jaws using ultralow-dose MDCT and the iterative techniques of ASIR and MBIR.

    PubMed

    Al-Ekrish, Asma'a A; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Widmann, Gerlig

    2016-10-01

    To assess the comparability of linear measurements of dental implant sites recorded from multidetector computed tomography (MDCT) images obtained using standard-dose filtered backprojection (FBP) technique with those from various ultralow doses combined with FBP, adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR) techniques. The results of the study may contribute to MDCT dose optimization for dental implant site imaging. MDCT scans of two cadavers were acquired using a standard reference protocol and four ultralow-dose test protocols (TP). The volume CT dose index of the different dose protocols ranged from a maximum of 30.48-36.71 mGy to a minimum of 0.44-0.53 mGy. All scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Linear measurements were recorded from standardized images of the jaws by two examiners. Intra- and inter-examiner reliability of the measurements were analyzed using Cronbach's alpha and inter-item correlation. Agreement between the measurements obtained with the reference-dose/FBP protocol and each of the test protocols was determined with Bland-Altman plots and linear regression. Statistical significance was set at a P-value of 0.05. No systematic variation was found between the linear measurements obtained with the reference protocol and the other imaging protocols. The only exceptions were TP3/ASIR-50 (bone kernel) and TP4/ASIR-100 (bone and standard kernels). The mean measurement differences between these three protocols and the reference protocol were within ±0.1 mm, with the 95 % confidence interval limits being within the range of ±1.15 mm. A nearly 97.5 % reduction in dose did not significantly affect the height and width measurements of edentulous jaws regardless of the reconstruction algorithm used.

  6. Comparison of seven protocols to identify fecal contamination sources using Escherichia coli

    USGS Publications Warehouse

    Stoeckel, D.M.; Mathes, M.V.; Hyer, K.E.; Hagedorn, C.; Kator, H.; Lukasik, J.; O'Brien, T. L.; Fenger, T.W.; Samadpour, M.; Strickler, K.M.; Wiggins, B.A.

    2004-01-01

    Microbial source tracking (MST) uses various approaches to classify fecal-indicator microorganisms to source hosts. Reproducibility, accuracy, and robustness of seven phenotypic and genotypic MST protocols were evaluated by use of Escherichia coli from an eight-host library of known-source isolates and a separate, blinded challenge library. In reproducibility tests, measuring each protocol's ability to reclassify blinded replicates, only one (pulsed-field gel electrophoresis; PFGE) correctly classified all test replicates to host species; three protocols classified 48-62% correctly, and the remaining three classified fewer than 25% correctly. In accuracy tests, measuring each protocol's ability to correctly classify new isolates, ribotyping with EcoRI and PvuII approached 100% correct classification but only 6% of isolates were classified; four of the other six protocols (antibiotic resistance analysis, PFGE, and two repetitive-element PCR protocols) achieved better than random accuracy rates when 30-100% of challenge isolates were classified. In robustness tests, measuring each protocol's ability to recognize isolates from nonlibrary hosts, three protocols correctly classified 33-100% of isolates as "unknown origin," whereas four protocols classified all isolates to a source category. A relevance test, summarizing interpretations for a hypothetical water sample containing 30 challenge isolates, indicated that false-positive classifications would hinder interpretations for most protocols. Study results indicate that more representation in known-source libraries and better classification accuracy would be needed before field application. Thorough reliability assessment of classification results is crucial before and during application of MST protocols.

  7. Bioindicators in the MIDUS National Study: Protocol, Measures, Sample, and Comparative Context

    PubMed Central

    Love, Gayle Dienberg; Seeman, Teresa E.; Weinstein, Maxine; Ryff, Carol D.

    2010-01-01

    Objectives MIDUS is a national study of health and aging among individuals aged 25 to 74 at baseline(1995/96). Longitudinal survey assessments (2004/05), were followed by biological assessments on a subsample aged 35–85. To facilitate public use, we describe the protocol, measures, and sample. Methods Respondents traveled to clinics for a two-day data collection protocol that included fasting blood specimens, 12-hour urine specimen, medical history, physical exam, bone densitometry, a laboratory challenge (heart rate variability, blood pressure, respiration, salivary cortisol). Results Response rates for the biological protocol (N = 1,255) were 39.3%, or 43.1% (adjusting for those who could not be located or contacted). Reasons for non-participation were travel, family obligations, and being too busy. Respondents were comparable to the recruitment pool on most demographic characteristics and health assessments. Discussion Strengths of the protocol vis-à-vis other similar studies include opportunities to link biological factors with diverse content from other MIDUS projects. PMID:20876364

  8. Development of an HPV Educational Protocol for Adolescents

    PubMed Central

    Wetzel, Caitlin; Tissot, Abbigail; Kollar, Linda M.; Hillard, Paula A.; Stone, Rachel; Kahn, Jessica A.

    2007-01-01

    Study Objectives To develop an educational protocol about HPV and Pap tests for adolescents, to evaluate the protocol for understandability and clarity, and to evaluate the protocol for its effectiveness in increasing knowledge about HPV. Design In phase 1, investigators and adolescents developed the protocol. In phase 2, adolescents evaluated the protocol qualitatively, investigators evaluated its effectiveness in increasing HPV knowledge in a sample of adolescents, and the protocol was revised. In phase 3, investigators evaluated the effectiveness of the revised protocol in an additional adolescent sample. Setting Urban, hospital-based teen health center. Participants A total of 252 adolescent girls and boys in the three study phases. Main Outcome Measures Pre- and post-protocol knowledge about HPV, measured using a 10- or 11-item scale. Results Scores on the HPV knowledge scale increased significantly (p<.0001) among adolescents who participated in phases 2 and 3 after they received the protocol. Initial differences in scores based on race, insurance type and condom use were not noted post-protocol. Conclusion The protocol significantly increased knowledge scores about HPV in this population, regardless of sociodemographic characteristics and risk behaviors. Effective, developmentally appropriate educational protocols about HPV and Pap tests are particularly important in clinical settings as cervical cancer screening guidelines evolve, HPV DNA testing is integrated into screening protocols, and HPV vaccines become available. In-depth, one-on-one education about HPV may also prevent adverse psychosocial responses and promote healthy sexual and Pap screening behaviors in adolescents with abnormal HPV or Pap test results. Synopsis The investigators developed an educational protocol about HPV and Pap tests and evaluated its effectiveness in increasing knowledge about HPV among adolescents. PMID:17868894

  9. Comparison of human septal nuclei MRI measurements using automated segmentation and a new manual protocol based on histology

    PubMed Central

    Butler, Tracy; Zaborszky, Laszlo; Pirraglia, Elizabeth; Li, Jinyu; Wang, Xiuyuan Hugh; Li, Yi; Tsui, Wai; Talos, Delia; Devinsky, Orrin; Kuchna, Izabela; Nowicki, Krzysztof; French, Jacqueline; Kuzniecky, Rubin; Wegiel, Jerzy; Glodzik, Lidia; Rusinek, Henry; DeLeon, Mony J.; Thesen, Thomas

    2014-01-01

    Septal nuclei, located in basal forebrain, are strongly connected with hippocampi and important in learning and memory, but have received limited research attention in human MRI studies. While probabilistic maps for estimating septal volume on MRI are now available, they have not been independently validated against manual tracing of MRI, typically considered the gold standard for delineating brain structures. We developed a protocol for manual tracing of the human septal region on MRI based on examination of neuroanatomical specimens. We applied this tracing protocol to T1 MRI scans (n=86) from subjects with temporal epilepsy and healthy controls to measure septal volume. To assess the inter-rater reliability of the protocol, a second tracer used the same protocol on 20 scans that were randomly selected from the 72 healthy controls. In addition to measuring septal volume, maximum septal thickness between the ventricles was measured and recorded. The same scans (n=86) were also analysed using septal probabilistic maps and Dartel toolbox in SPM. Results show that our manual tracing algorithm is reliable, and that septal volume measurements obtained via manual and automated methods correlate significantly with each other (p<001). Both manual and automated methods detected significantly enlarged septal nuclei in patients with temporal lobe epilepsy in accord with a proposed compensatory neuroplastic process related to the strong connections between septal nuclei and hippocampi. Septal thickness, which was simple to measure with excellent inter-rater reliability, correlated well with both manual and automated septal volume, suggesting it could serve as an easy-to-measure surrogate for septal volume in future studies. Our results call attention to the important though understudied human septal region, confirm its enlargement in temporal lobe epilepsy, and provide a reliable new manual delineation protocol that will facilitate continued study of this critical region. PMID:24736183

  10. Comparison of human septal nuclei MRI measurements using automated segmentation and a new manual protocol based on histology.

    PubMed

    Butler, Tracy; Zaborszky, Laszlo; Pirraglia, Elizabeth; Li, Jinyu; Wang, Xiuyuan Hugh; Li, Yi; Tsui, Wai; Talos, Delia; Devinsky, Orrin; Kuchna, Izabela; Nowicki, Krzysztof; French, Jacqueline; Kuzniecky, Rubin; Wegiel, Jerzy; Glodzik, Lidia; Rusinek, Henry; deLeon, Mony J; Thesen, Thomas

    2014-08-15

    Septal nuclei, located in basal forebrain, are strongly connected with hippocampi and important in learning and memory, but have received limited research attention in human MRI studies. While probabilistic maps for estimating septal volume on MRI are now available, they have not been independently validated against manual tracing of MRI, typically considered the gold standard for delineating brain structures. We developed a protocol for manual tracing of the human septal region on MRI based on examination of neuroanatomical specimens. We applied this tracing protocol to T1 MRI scans (n=86) from subjects with temporal epilepsy and healthy controls to measure septal volume. To assess the inter-rater reliability of the protocol, a second tracer used the same protocol on 20 scans that were randomly selected from the 72 healthy controls. In addition to measuring septal volume, maximum septal thickness between the ventricles was measured and recorded. The same scans (n=86) were also analyzed using septal probabilistic maps and DARTEL toolbox in SPM. Results show that our manual tracing algorithm is reliable, and that septal volume measurements obtained via manual and automated methods correlate significantly with each other (p<.001). Both manual and automated methods detected significantly enlarged septal nuclei in patients with temporal lobe epilepsy in accord with a proposed compensatory neuroplastic process related to the strong connections between septal nuclei and hippocampi. Septal thickness, which was simple to measure with excellent inter-rater reliability, correlated well with both manual and automated septal volume, suggesting it could serve as an easy-to-measure surrogate for septal volume in future studies. Our results call attention to the important though understudied human septal region, confirm its enlargement in temporal lobe epilepsy, and provide a reliable new manual delineation protocol that will facilitate continued study of this critical region. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Anthropometric protocols for the construction of new international fetal and newborn growth standards: the INTERGROWTH-21st Project.

    PubMed

    Cheikh Ismail, L; Knight, H E; Bhutta, Z; Chumlea, W C

    2013-09-01

    The primary aim of the INTERGROWTH-21(st) Project is to construct new, prescriptive standards describing optimal fetal and preterm postnatal growth. The anthropometric measurements include the head circumference, recumbent length and weight of the infants, and the stature and weight of the parents. In such a large, international, multicentre project, it is critical that all study sites follow standardised protocols to ensure maximal validity of the growth and nutrition indicators used. This paper describes, in detail, the selection of anthropometric personnel, equipment, and measurement and calibration protocols used to construct the new standards. Implementing these protocols at each study site ensures that the anthropometric data are of the highest quality to construct the international standards. © 2013 Royal College of Obstetricians and Gynaecologists.

  12. Challenges in standardization of blood pressure measurement at the population level.

    PubMed

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  13. Advanced Global Atmospheric Gases Experiment (AGAGE)

    NASA Technical Reports Server (NTRS)

    Prinn, Ronald G.; Kurylo, Michael (Technical Monitor)

    2004-01-01

    We seek funding from NASA for the third year (2005) of the four-year period January 1, 2003 - December 31, 2006 for continued support of the MIT contributions to the multi-national global atmospheric trace species measurement program entitled Advanced Global Atmospheric Gases Experiment (AGAGE). The case for real-time high-frequency measurement networks like AGAGE is very strong and the observations and their interpretation are widely recognized for their importance to ozone depletion and climate change studies and to verification issues arising from the Montreal Protocol (ozone) and Kyoto Protocol (climate). The proposed AGAGE program is distinguished by its capability to measure over the globe at high frequency almost all of the important species in the Montreal Protocol and almost all of the significant non-CO2 gases in the Kyoto Protocol.

  14. Measurement-device-independent quantum key distribution for Scarani-Acin-Ribordy-Gisin 04 protocol

    PubMed Central

    Mizutani, Akihiro; Tamaki, Kiyoshi; Ikuta, Rikizo; Yamamoto, Takashi; Imoto, Nobuyuki

    2014-01-01

    The measurement-device-independent quantum key distribution (MDI QKD) was proposed to make BB84 completely free from any side-channel in detectors. Like in prepare & measure QKD, the use of other protocols in MDI setting would be advantageous in some practical situations. In this paper, we consider SARG04 protocol in MDI setting. The prepare & measure SARG04 is proven to be able to generate a key up to two-photon emission events. In MDI setting we show that the key generation is possible from the event with single or two-photon emission by a party and single-photon emission by the other party, but the two-photon emission event by both parties cannot contribute to the key generation. On the contrary to prepare & measure SARG04 protocol where the experimental setup is exactly the same as BB84, the measurement setup for SARG04 in MDI setting cannot be the same as that for BB84 since the measurement setup for BB84 in MDI setting induces too many bit errors. To overcome this problem, we propose two alternative experimental setups, and we simulate the resulting key rate. Our study highlights the requirements that MDI QKD poses on us regarding with the implementation of a variety of QKD protocols. PMID:24913431

  15. Level of adherence to an extravasation protocol over 10 years in a tertiary care hospital.

    PubMed

    Molas-Ferrer, Gloria; Farré-Ayuso, Elisabet; doPazo-Oubiña, Fernando; deAndrés-Lázaro, Ana; Guell-Picazo, Jaume; Borrás-Maixenchs, Núria; Corominas-Bosch, Lourdes; Valverde-Bosch, Montserrat; Creus-Baró, Natalia

    2015-04-01

    Extravasation of chemotherapy is an undesirable complication related to the administration of antineoplastic therapy. Establishing the real incidence is difficult. Because of the importance of a quick intervention after an extravasation, every hospital should have an extravasation protocol. The purpose of this study was to determine the degree of observance of an extravasation protocol by nursing staff and to determine extravasation incidence. This descriptive, longitudinal, retrospective study was set in a tertiary-level hospital. The researchers reviewed 117 extravasation notification forms received by the pharmacy department during a 10-year period. Nursing actuation, particularly observance of the extravasation protocol, was analyzed. Protocol adherence was 89%. Twelve deviations from the protocol in the application of recommended measures were detected. An antidote was used in 41 patients, and temperature measures were applied in 14 cases. Ninety-nine patients had at least one episode of reported follow-up. No cases of necrosis or skin ulcers were described, except by one patient, who developed a delayed skin ulcer to vinorelbine. Drugs most frequently reported were etoposide, carboplatin, and paclitaxel. Nursing staff should be continuously trained in extravasation protocol because a rapid actuation can prevent skin lesions.

  16. Comparison of low- and ultralow-dose computed tomography protocols for quantitative lung and airway assessment.

    PubMed

    Hammond, Emily; Sloan, Chelsea; Newell, John D; Sieren, Jered P; Saylor, Melissa; Vidal, Craig; Hogue, Shayna; De Stefano, Frank; Sieren, Alexa; Hoffman, Eric A; Sieren, Jessica C

    2017-09-01

    Quantitative computed tomography (CT) measures are increasingly being developed and used to characterize lung disease. With recent advances in CT technologies, we sought to evaluate the quantitative accuracy of lung imaging at low- and ultralow-radiation doses with the use of iterative reconstruction (IR), tube current modulation (TCM), and spectral shaping. We investigated the effect of five independent CT protocols reconstructed with IR on quantitative airway measures and global lung measures using an in vivo large animal model as a human subject surrogate. A control protocol was chosen (NIH-SPIROMICS + TCM) and five independent protocols investigating TCM, low- and ultralow-radiation dose, and spectral shaping. For all scans, quantitative global parenchymal measurements (mean, median and standard deviation of the parenchymal HU, along with measures of emphysema) and global airway measurements (number of segmented airways and pi10) were generated. In addition, selected individual airway measurements (minor and major inner diameter, wall thickness, inner and outer area, inner and outer perimeter, wall area fraction, and inner equivalent circle diameter) were evaluated. Comparisons were made between control and target protocols using difference and repeatability measures. Estimated CT volume dose index (CTDIvol) across all protocols ranged from 7.32 mGy to 0.32 mGy. Low- and ultralow-dose protocols required more manual editing and resolved fewer airway branches; yet, comparable pi10 whole lung measures were observed across all protocols. Similar trends in acquired parenchymal and airway measurements were observed across all protocols, with increased measurement differences using the ultralow-dose protocols. However, for small airways (1.9 ± 0.2 mm) and medium airways (5.7 ± 0.4 mm), the measurement differences across all protocols were comparable to the control protocol repeatability across breath holds. Diameters, wall thickness, wall area fraction, and equivalent diameter had smaller measurement differences than area and perimeter measurements. In conclusion, the use of IR with low- and ultralow-dose CT protocols with CT volume dose indices down to 0.32 mGy maintains selected quantitative parenchymal and airway measurements relevant to pulmonary disease characterization. © 2017 American Association of Physicists in Medicine.

  17. Validation of Transtek blood pressure monitor TMB-1491 for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Tian, Huiyong; Zeng, Sijian; Zhong, Xiaoyan; Gong, Wei; Liu, Wenjun

    2015-10-01

    Transtek blood pressure monitor TMB-1491 is an automatic upper arm device designed for self/home measurement in adult populations. This study aimed to evaluate its accuracy according to the European Society of Hypertension International Protocol revision 2010. The protocol requirements were followed precisely with the recruitment of 33 adult individuals on whom same-left-arm sequential systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements were obtained in this study (three pairs for each of the 33 participants). The device produced 74, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 85, 97, and 99 for DBP, respectively. The mean±SD device-observer difference was -0.6±4.4 mmHg for SBP and -0.6±3.4 mmHg for DBP. The number of participants with two or three device-observer difference within 5 mmHg was 24 for SBP and 29 for DBP. In addition, none of the participants had a device-observer difference within 5 mmHg for SBP, and three of the participants had the same for DBP. Transtek TMB-1491 has passed all phases of European Society of Hypertension International Protocol revision 2010 and can be recommended for self/home measurement in adult populations.

  18. Enhancing robustness of multiparty quantum correlations using weak measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Uttam, E-mail: uttamsingh@hri.res.in; Mishra, Utkarsh, E-mail: utkarsh@hri.res.in; Dhar, Himadri Shekhar, E-mail: dhar.himadri@gmail.com

    Multipartite quantum correlations are important resources for the development of quantum information and computation protocols. However, the resourcefulness of multipartite quantum correlations in practical settings is limited by its fragility under decoherence due to environmental interactions. Though there exist protocols to protect bipartite entanglement under decoherence, the implementation of such protocols for multipartite quantum correlations has not been sufficiently explored. Here, we study the effect of local amplitude damping channel on the generalized Greenberger–Horne–Zeilinger state, and use a protocol of optimal reversal quantum weak measurement to protect the multipartite quantum correlations. We observe that the weak measurement reversal protocol enhancesmore » the robustness of multipartite quantum correlations. Further it increases the critical damping value that corresponds to entanglement sudden death. To emphasize the efficacy of the technique in protection of multipartite quantum correlation, we investigate two proximately related quantum communication tasks, namely, quantum teleportation in a one sender, many receivers setting and multiparty quantum information splitting, through a local amplitude damping channel. We observe an increase in the average fidelity of both the quantum communication tasks under the weak measurement reversal protocol. The method may prove beneficial, for combating external interactions, in other quantum information tasks using multipartite resources. - Highlights: • Extension of weak measurement reversal scheme to protect multiparty quantum correlations. • Protection of multiparty quantum correlation under local amplitude damping noise. • Enhanced fidelity of quantum teleportation in one sender and many receivers setting. • Enhanced fidelity of quantum information splitting protocol.« less

  19. Evaluation of a single-scan protocol for radiochromic film dosimetry.

    PubMed

    Shimohigashi, Yoshinobu; Araki, Fujio; Maruyama, Masato; Nakaguchi, Yuji; Kuwahara, Satoshi; Nagasue, Nozomu; Kai, Yudai

    2015-03-08

    The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calibration film, and unirradiated film. The single-scan protocol was scanned 30 min after film irradiation. The EBT3 calibration curves were obtained with the multichannel film dosimetry method. The dose verifications for each protocol were performed with the step pattern, pyramid pattern, and clinical treatment plans for intensity-modulated radiation therapy (IMRT). The absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (TPS) using gamma evaluation at 3% and 3 mm. The dose distribution for the single-scan protocol was within 2% of the 24-hr protocol dose distribution. For the step pattern, the absolute dose discrepancies between the TPS for the single-scan and 24-hr protocols were 2.0 ± 1.8 cGy and 1.4 ± 1.2 cGy at the dose plateau, respectively. The pass rates were 96.0% for the single-scan protocol and 95.9% for the 24-hr protocol. Similarly, the dose discrepancies for the pyramid pattern were 3.6 ± 3.5cGy and 2.9 ± 3.3 cGy, respectively, while the pass rates for the pyramid pattern were 95.3% and 96.4%, respectively. The average pass rates for the four IMRT plans were 96.7% ± 1.8% for the single-scan protocol and 97.3% ± 1.4% for the 24-hr protocol. Thus, the single-scan protocol measurement is useful for dose verification of IMRT, based on its accuracy and efficiency.

  20. Evaluation of a single‐scan protocol for radiochromic film dosimetry

    PubMed Central

    Araki, Fujio; Maruyama, Masato; Nakaguchi, Yuji; Kuwahara, Satoshi; Nagasue, Nozomu; Kai, Yudai

    2015-01-01

    The purpose of this study was to evaluate a single‐scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24‐hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24‐hr protocol). The single‐scan protocol enables measurement results within a short time using only the verification film, one calibration film, and unirradiated film. The single‐scan protocol was scanned 30 min after film irradiation. The EBT3 calibration curves were obtained with the multichannel film dosimetry method. The dose verifications for each protocol were performed with the step pattern, pyramid pattern, and clinical treatment plans for intensity‐modulated radiation therapy (IMRT). The absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (TPS) using gamma evaluation at 3% and 3 mm. The dose distribution for the single‐scan protocol was within 2% of the 24‐hr protocol dose distribution. For the step pattern, the absolute dose discrepancies between the TPS for the single‐scan and 24‐hr protocols were 2.0±1.8 cGy and 1.4±1.2 cGy at the dose plateau, respectively. The pass rates were 96.0% for the single‐scan protocol and 95.9% for the 24‐hr protocol. Similarly, the dose discrepancies for the pyramid pattern were 3.6±3.5 cGy and 2.9±3.3 cGy, respectively, while the pass rates for the pyramid pattern were 95.3% and 96.4%, respectively. The average pass rates for the four IMRT plans were 96.7%±1.8% for the single‐scan protocol and 97.3%±1.4% for the 24‐hr protocol. Thus, the single‐scan protocol measurement is useful for dose verification of IMRT, based on its accuracy and efficiency. PACS number: 87.55.Qr PMID:26103194

  1. Collective attacks and unconditional security in continuous variable quantum key distribution.

    PubMed

    Grosshans, Frédéric

    2005-01-21

    We present here an information theoretic study of Gaussian collective attacks on the continuous variable key distribution protocols based on Gaussian modulation of coherent states. These attacks, overlooked in previous security studies, give a finite advantage to the eavesdropper in the experimentally relevant lossy channel, but are not powerful enough to reduce the range of the reverse reconciliation protocols. Secret key rates are given for the ideal case where Bob performs optimal collective measurements, as well as for the realistic cases where he performs homodyne or heterodyne measurements. We also apply the generic security proof of Christiandl et al. to obtain unconditionally secure rates for these protocols.

  2. Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

    NASA Astrophysics Data System (ADS)

    Farfurnik, D.; Jarmola, A.; Budker, D.; Bar-Gill, N.

    2018-01-01

    Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12C sample, we find that the Carr-Purcell-Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many (> 500) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (˜10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.

  3. Musculoskeletal MRI at 3.0 T and 7.0 T: a comparison of relaxation times and image contrast.

    PubMed

    Jordan, Caroline D; Saranathan, Manojkumar; Bangerter, Neal K; Hargreaves, Brian A; Gold, Garry E

    2013-05-01

    The purpose of this study was to measure and compare the relaxation times of musculoskeletal tissues at 3.0 T and 7.0 T, and to use these measurements to select appropriate parameters for musculoskeletal protocols at 7.0 T. We measured the T₁ and T₂ relaxation times of cartilage, muscle, synovial fluid, bone marrow and subcutaneous fat at both 3.0 T and 7.0 T in the knees of five healthy volunteers. The T₁ relaxation times were measured using a spin-echo inversion recovery sequence with six inversion times. The T₂ relaxation times were measured using a spin-echo sequence with seven echo times. The accuracy of both the T₁ and T₂ measurement techniques was verified in phantoms at both magnetic field strengths. We used the measured relaxation times to help design 7.0 T musculoskeletal protocols that preserve the favorable contrast characteristics of our 3.0 T protocols, while achieving significantly higher resolution at higher SNR efficiency. The T₁ relaxation times in all tissues at 7.0 T were consistently higher than those measured at 3.0 T, while the T₂ relaxation times at 7.0 T were consistently lower than those measured at 3.0 T. The measured relaxation times were used to help develop high resolution 7.0 T protocols that had similar fluid-to-cartilage contrast to that of the standard clinical 3.0 T protocols for the following sequences: proton-density-weighted fast spin-echo (FSE), T₂-weighted FSE, and 3D-FSE-Cube. The T₁ and T₂ changes were within the expected ranges. Parameters for musculoskeletal protocols at 7.0 T can be optimized based on these values, yielding improved resolution in musculoskeletal imaging with similar contrast to that of standard 3.0 T clinical protocols. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. Components That Affect the Personal Motivation to Implement Campus Safety Protocols

    ERIC Educational Resources Information Center

    Burt, Ernest, III

    2013-01-01

    This study examined components that have an effect on crisis response team members' personal motivation to perform campus safety protocols. The research method for this study was a quantitative design. The variables measured were compensation, experience, training, and communication. The motivation sources for this study included instrumental…

  5. Validity of Assessments of Youth Access to Tobacco: The Familiarity Effect

    PubMed Central

    Landrine, Hope; Klonoff, Elizabeth A.

    2003-01-01

    Objectives. We examined the standard compliance protocol and its validity as a measure of youth access to tobacco. Methods. In Study 1, youth smokers reported buying cigarettes in stores where they are regular customers. In Study 2, youths attempted to purchase cigarettes by using the Standard Protocol, in which they appeared at stores once for cigarettes, and by using the Familiarity Protocol, in which they were rendered regular customers by purchasing nontobacco items 4 times and then requested cigarettes during their fifth visit. Results. Sales to youths aged 17 years in the Familiarity Protocol were significantly higher than sales to the same age group in the Standard Protocols (62.5% vs. 6%, respectively). Conclusions. The Standard Protocol does not match how youths obtain cigarettes. Access is low for stranger youths within compliance studies, but access is high for familiar youths outside of compliance studies. PMID:14600057

  6. Towards an improved LAI collection protocol via simulated field-based PAR sensing

    DOE PAGES

    Yao, Wei; Van Leeuwen, Martin; Romanczyk, Paul; ...

    2016-07-14

    In support of NASA’s next-generation spectrometer—the Hyperspectral Infrared Imager (HyspIRI)—we are working towards assessing sub-pixel vegetation structure from imaging spectroscopy data. Of particular interest is Leaf Area Index (LAI), which is an informative, yet notoriously challenging parameter to efficiently measure in situ. While photosynthetically-active radiation (PAR) sensors have been validated for measuring crop LAI, there is limited literature on the efficacy of PAR-based LAI measurement in the forest environment. This study (i) validates PAR-based LAI measurement in forest environments, and (ii) proposes a suitable collection protocol, which balances efficiency with measurement variation, e.g., due to sun flecks and various-sized canopymore » gaps. A synthetic PAR sensor model was developed in the Digital Imaging and Remote Sensing Image Generation (DIRSIG) model and used to validate LAI measurement based on first-principles and explicitly-known leaf geometry. Simulated collection parameters were adjusted to empirically identify optimal collection protocols. Furthermore, these collection protocols were then validated in the field by correlating PAR-based LAI measurement to the normalized difference vegetation index (NDVI) extracted from the “classic” Airborne Visible Infrared Imaging Spectrometer (AVIRIS-C) data (R 2 was 0.61). The results indicate that our proposed collecting protocol is suitable for measuring the LAI of sparse forest (LAI < 3–5 ( m 2/m 2)).« less

  7. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT).

    PubMed

    Topouchian, Jirar A; El Assaad, Mohamed A; Orobinskaia, Ludmila V; El Feghali, Ramzi N; Asmar, Roland G

    2006-06-01

    Two electronic devices for self-measurement of blood pressure - a brachial monitor, the Omron M6, and a wrist monitor, the Omron R7 - were evaluated in two separate studies according to the International Protocol of the European Society of Hypertension. The International Validation Protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood pressure measurements) making a total number of 33 participants (99 pairs of blood pressure measurements) on whom the final validation is performed. The same methodology recommended by the European Society of Hypertension protocol was applied for both studies. In each study and for each participant, four blood pressure measurements were taken simultaneously by two trained observers using mercury sphygmomanometers alternately with three measurements taken by the tested device. The difference between the blood pressure value given by the device and that obtained by the two observers (mean of the two observers) was calculated for each measure. The 99 pairs of blood pressure differences were classified into three categories (

  8. Analyzing the effect of routing protocols on media access control protocols in radio networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, C. L.; Drozda, M.; Marathe, A.

    2002-01-01

    We study the effect of routing protocols on the performance of media access control (MAC) protocols in wireless radio networks. Three well known MAC protocols: 802.11, CSMA, and MACA are considered. Similarly three recently proposed routing protocols: AODV, DSR and LAR scheme 1 are considered. The experimental analysis was carried out using GloMoSim: a tool for simulating wireless networks. The main focus of our experiments was to study how the routing protocols affect the performance of the MAC protocols when the underlying network and traffic parameters are varied. The performance of the protocols was measured w.r.t. five important parameters: (i)more » number of received packets, (ii) average latency of each packet, (iii) throughput (iv) long term fairness and (v) number of control packets at the MAC layer level. Our results show that combinations of routing and MAC protocols yield varying performance under varying network topology and traffic situations. The result has an important implication; no combination of routing protocol and MAC protocol is the best over all situations. Also, the performance analysis of protocols at a given level in the protocol stack needs to be studied not locally in isolation but as a part of the complete protocol stack. A novel aspect of our work is the use of statistical technique, ANOVA (Analysis of Variance) to characterize the effect of routing protocols on MAC protocols. This technique is of independent interest and can be utilized in several other simulation and empirical studies.« less

  9. A Linguistic Feature Comparison of the Verbal Protocols of Good and Poor Readers on Standardized Measures of Reading Comprehension.

    ERIC Educational Resources Information Center

    Kavale, Kenneth A.

    Sixteen sixth-grade students participated in a study of the reasoning strategies employed by good and poor readers. Students, trained in applying introspective procedures, completed instruments that measured verbal reasoning, determining cause and effect, reading for inference, and determining main idea. Protocols obtained during five consecutive…

  10. Conduct of a personal radiofrequency electromagnetic field measurement study: proposed study protocol.

    PubMed

    Röösli, Martin; Frei, Patrizia; Bolte, John; Neubauer, Georg; Cardis, Elisabeth; Feychting, Maria; Gajsek, Peter; Heinrich, Sabine; Joseph, Wout; Mann, Simon; Martens, Luc; Mohler, Evelyn; Parslow, Roger C; Poulsen, Aslak Harbo; Radon, Katja; Schüz, Joachim; Thuroczy, György; Viel, Jean-François; Vrijheid, Martine

    2010-05-20

    The development of new wireless communication technologies that emit radio frequency electromagnetic fields (RF-EMF) is ongoing, but little is known about the RF-EMF exposure distribution in the general population. Previous attempts to measure personal exposure to RF-EMF have used different measurement protocols and analysis methods making comparisons between exposure situations across different study populations very difficult. As a result, observed differences in exposure levels between study populations may not reflect real exposure differences but may be in part, or wholly due to methodological differences. The aim of this paper is to develop a study protocol for future personal RF-EMF exposure studies based on experience drawn from previous research. Using the current knowledge base, we propose procedures for the measurement of personal exposure to RF-EMF, data collection, data management and analysis, and methods for the selection and instruction of study participants. We have identified two basic types of personal RF-EMF measurement studies: population surveys and microenvironmental measurements. In the case of a population survey, the unit of observation is the individual and a randomly selected representative sample of the population is needed to obtain reliable results. For microenvironmental measurements, study participants are selected in order to represent typical behaviours in different microenvironments. These two study types require different methods and procedures. Applying our proposed common core procedures in future personal measurement studies will allow direct comparisons of personal RF-EMF exposures in different populations and study areas.

  11. Conduct of a personal radiofrequency electromagnetic field measurement study: proposed study protocol

    PubMed Central

    2010-01-01

    Background The development of new wireless communication technologies that emit radio frequency electromagnetic fields (RF-EMF) is ongoing, but little is known about the RF-EMF exposure distribution in the general population. Previous attempts to measure personal exposure to RF-EMF have used different measurement protocols and analysis methods making comparisons between exposure situations across different study populations very difficult. As a result, observed differences in exposure levels between study populations may not reflect real exposure differences but may be in part, or wholly due to methodological differences. Methods The aim of this paper is to develop a study protocol for future personal RF-EMF exposure studies based on experience drawn from previous research. Using the current knowledge base, we propose procedures for the measurement of personal exposure to RF-EMF, data collection, data management and analysis, and methods for the selection and instruction of study participants. Results We have identified two basic types of personal RF-EMF measurement studies: population surveys and microenvironmental measurements. In the case of a population survey, the unit of observation is the individual and a randomly selected representative sample of the population is needed to obtain reliable results. For microenvironmental measurements, study participants are selected in order to represent typical behaviours in different microenvironments. These two study types require different methods and procedures. Conclusion Applying our proposed common core procedures in future personal measurement studies will allow direct comparisons of personal RF-EMF exposures in different populations and study areas. PMID:20487532

  12. Rehabilitation protocol for patellar tendinopathy applied among 16- to 19-year old volleyball players.

    PubMed

    Biernat, Ryszard; Trzaskoma, Zbigniew; Trzaskoma, Lukasz; Czaprowski, Dariusz

    2014-01-01

    The aim of the study was to investigate the efficacy of rehabilitation protocol applied during competitive period for the treatment of patellar tendinopathy. A total of 28 male volleyball players were divided into two groups. Fifteen from experimental group (E) and 13 from control group (C) fulfilled the same tests 3 times: before the training program started (first measurement), after 12 weeks (second measurement) and after 24 weeks (third measurement). The above-mentioned protocol included the following: USG imagining with color Doppler function, clinical testing, pain intensity evaluation with VISA-P questionnaire, leg muscle strength and power and jumping ability measurements. The key element of the rehabilitation program was eccentric squat on decline board with additional unstable surface. The essential factor of the protocol was a set of preventive functional exercises, with focus on eccentric exercises of hamstrings. Patellar tendinopathy was observed in 18% of the tested young volleyball players. Implementation of the presented rehabilitation protocol with eccentric squat on decline board applied during sports season lowered the pain level of the young volleyball players. Presented rehabilitation protocol applied without interrupting the competitive period among young volleyball players together with functional exercises could be an effective method for the treatment of patellar tendinopathy.

  13. NASA'S Standard Measures During Bed Rest: Adaptations in the Cardiovascular System

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M. C.; Feiveson, Alan H.; Martin, David S.; Cromwell, Roni L.; Platts, Steven H.; Stenger, Michael B.

    2016-01-01

    Bed rest is a well-accepted analog of space flight that has been used extensively to investigate physiological adaptations in a larger number of subjects in a shorter amount of time than can be studied with space flight and without the confounding effects associated with normal mission operations. However, comparison across studies of different bed rest durations, between sexes, and between various countermeasure protocols have been hampered by dissimilarities in bed rest conditions, measurement protocols, and testing schedules. To address these concerns, NASA instituted standard bed rest conditions and standard measures for all physiological disciplines participating in studies conducted at the Flight Analogs Research Unit (FARU) at the University of Texas-Medical Branch. Investigators for individual studies employed their own targeted study protocols to address specific hypothesis-driven questions, but standard measures tests were conducted within these studies on a non-interference basis to maximize data availability while reducing the need to implement multiple bed rest studies to understand the effects of a specific countermeasure. When possible, bed rest standard measures protocols were similar to tests nominally used for medically-required measures or research protocols conducted before and after Space Shuttle and International Space Station missions. Specifically, bed rest standard measures for the cardiovascular system implemented before, during, and after bed rest at the FARU included plasma volume (carbon monoxide rebreathing), cardiac mass and function (2D, 3D and Doppler echocardiography), and orthostatic tolerance testing (15- or 30-minutes of 80 degree head-up tilt). Results to-date indicate that when countermeasures are not employed, plasma volume decreases and the incidence of presyncope during head-up tilt is more frequent even after short-duration bed rest while reductions in cardiac function and mass are progressive as bed rest duration increases. Additionally, while plasma volume loss can be corrected and cardiac mass can be prevented with properly applied countermeasures, orthostatic tolerance is more difficult to protect when supine exercise is the only countermeasure. Similar results have been observed after space flight. Plasma volume, cardiac chamber volume, and orthostatic tolerance recover relatively quickly with resumption of ambulation and normal activity levels after bed rest but restoration of cardiac mass is prolonged.

  14. Calibration and data collection protocols for reliable lattice parameter values in electron pair distribution function studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abeykoon, A. M. Milinda; Hu, Hefei; Wu, Lijun

    2015-01-30

    Different protocols for calibrating electron pair distribution function (ePDF) measurements are explored and described for quantitative studies on nanomaterials. It is found that the most accurate approach to determine the camera length is to use a standard calibration sample of Au nanoparticles from the National Institute of Standards and Technology. Different protocols for data collection are also explored, as are possible operational errors, to find the best approaches for accurate data collection for quantitative ePDF studies.

  15. Calibration and data collection protocols for reliable lattice parameter values in electron pair distribution function (ePDF) studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abeykoon, A. M. Milinda; Hu, Hefei; Wu, Lijun

    2015-02-01

    We explore and describe different protocols for calibrating electron pair distribution function (ePDF) measurements for quantitative studies on nano-materials. We find the most accurate approach to determine the camera-length is to use a standard calibration sample of Au nanoparticles from National Institute of Standards and Technology. Different protocols for data collection are also explored, as are possible operational errors, to find the best approaches for accurate data collection for quantitative ePDF studies.

  16. Development of pig welfare assessment protocol integrating animal-, environment-, and management-based measures.

    PubMed

    Renggaman, Anriansyah; Choi, Hong L; Sudiarto, Sartika Ia; Alasaarela, Laura; Nam, Ok S

    2015-01-01

    Due to increased interest in animal welfare, there is now a need for a comprehensive assessment protocol to be used in intensive pig farming systems. There are two current welfare assessment protocols for pigs: Welfare Quality® Assessment Protocols (applicable in the Europe Union), that mostly focuses on animal-based measures, and the Swine Welfare Assurance Program (applicable in the United States), that mostly focuses on management- and environment-based measures. In certain cases, however, animal-based measures might not be adequate for properly assessing pig welfare status. Similarly, welfare assessment that relies only on environment- and management-based measures might not represent the actual welfare status of pigs. Therefore, the objective of this paper was to develop a new welfare protocol by integrating animal-, environment-, and management-based measures. The background for selection of certain welfare criteria and modification of the scoring systems from existing welfare assessment protocols are described. The developed pig welfare assessment protocol consists of 17 criteria that are related to four main principles of welfare (good feeding, good housing, good health, and appropriate behavior). Good feeding, good housing, and good health were assessed using a 3-point scale: 0 (good welfare), 1 (moderate welfare), and 2 (poor welfare). In certain cases, only a 2-point scale was used: 0 (certain condition is present) or 2 (certain condition is absent). Appropriate behavior was assessed by scan sampling of positive and negative social behaviors based on qualitative behavior assessment and human-animal relationship tests. Modification of the body condition score into a 3-point scale revealed pigs with a moderate body condition (score 1). Moreover, additional criteria such as feed quality confirmed that farms had moderate (score 1) or poor feed quality (score 2), especially those farms located in a high relative humidity region. The developed protocol can be utilized to assess welfare status in an intensive pig farming system. Although further improvements are still needed, this study is a first step in developing a pig welfare assessment protocol that combines animal-, environment-, and management-based measures.

  17. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.

    PubMed

    Pini, Claudio; Pastori, Marco; Baccheschi, Jordan; Omboni, Stefano; Parati, Gianfranco

    2007-06-01

    There is evidence that blood pressure measurement outside the doctor's office can provide valuable information for the diagnostic evaluation of hypertensive patients and for monitoring their response to treatment. Home blood pressure monitoring devices have a major role in this setting, provided that their accuracy in measuring blood pressure is demonstrated by validation studies. This study aimed at verifying whether the automatic electronic oscillometric blood pressure measuring device Artsana CSI 610 complied with the standard of accuracy indicated by the ESH International Protocol. Sequential measurements of systolic and diastolic blood pressure were obtained in 33 participants using the mercury sphygmomanometer (two observers) and the test device (one supervisor). A standard adult cuff was always employed during the study. According to the ESH validation protocol, 99 couples of test device and reference blood pressure measurements were obtained during the two phases of the study (three pairs for each of the 33 participants). The Artsana CSI 610 device successfully passed phase 1 of study validation with the number of absolute differences between test and reference device never <35 within 5 mmHg and never <40 within 10 and 15 mmHg. The test device also passed phase 2 of the validation study with a mean (+/-SD) device-observer difference of -1.4+/-4.8 mmHg for systolic and -0.9+/-3.5 mmHg for diastolic blood pressure. According to the results of the validation study on the basis of the ESH International Protocol, the Artsana CSI 610 can be recommended for clinical use in adults.

  18. Regulation of human retinal blood flow by endothelin-1.

    PubMed

    Polak, Kaija; Luksch, Alexandra; Frank, Barbara; Jandrasits, Kerstin; Polska, Elzbieta; Schmetterer, Leopold

    2003-05-01

    There is evidence from in vitro and animal studies that endothelin is a major regulator of retinal blood flow. We set out to characterize the role of the endothelin-system in the blood flow control of the human retina. Two studies in healthy subjects were performed. The study design was randomized, placebo-controlled, double-masked, balanced, two-way crossover in protocol A and three way-way crossover in protocol B. In protocol A 18 healthy male subjects received intravenous endothelin-1 (ET-1) in a dose of 2.5 ng kg (-1)min(-1) for 30 min or placebo on two different study days and retinal vessel diameters were measured. In protocol B 12 healthy male subjects received ET-1 in stepwise increasing doses of 0, 1.25, 2.5 and 5 ng kg (-1)min(-1) (each infusion step over 20 min) in co-infusion with the specific ET(A)-receptor antagonist BQ123 (60 microg min (-1)) or placebo or BQ123 alone investigating retinal vessel diameters, retinal blood velocity and retinal blood flow. Measurements of retinal vessel size were done with the Zeiss retinal vessel analyzer. Measurements of blood velocities were done with bi-directional laser Doppler velocimetry. From these measurements retinal blood flow was calculated. In protocol A exogenous ET-1 tended to decrease retinal arterial diameter, but this effect was not significant versus placebo. No effect on retinal venous diameter was seen. In protocol B retinal venous blood velocity and retinal blood flow was significantly reduced after administration of exogenous ET-1. These effects were significantly blunted when BQ-123 was co-administered. By contrast, BQ-123 alone had no effect on retinal hemodynamic parameters. Concluding, BQ123 antagonizes the effects of exogenously administered ET-1 on retinal blood flow in healthy subjects. In addition, the results of the present study are compatible with the hypothesis that ET-1 exerts its vasoconstrictor effects in the retina mainly on the microvessels.

  19. Feasibility and limitations of the round robin test for assessment of in vitro chondrogenesis evaluation protocol in a tissue-engineered medical product.

    PubMed

    Yokoi, Masako; Hattori, Koji; Narikawa, Koichi; Ohgushi, Hajime; Tadokoro, Mika; Hoshi, Kazuto; Takato, Tsuyoshi; Myoui, Akira; Nanno, Katsuhiko; Kato, Yukio; Kanawa, Masami; Sugawara, Katsura; Kobo, Tomoko; Ushida, Takashi

    2012-07-01

    Tissue-engineered medical products (TEMPs) should be evaluated before implantation. Therefore, it is indispensable to establish evaluation protocols in regenerative medicine. Whether or not such evaluation protocols are reasonable is generally verified through a 'round robin' test. However, the round robin test for TEMPs intrinsically includes a deficiency, because 'identical' specimens can not be prepared for TEMPs. The aim of the study was to assess the feasibility and limitations of the round robin test for TEMPs by using a prepared evaluation protocol. We adopted tissue-engineered cartilage constructs as delivered specimens and a protocol of measuring sGAG content as an evaluation protocol proposed to ISO TC150/SC7, which is an invasive, but usually applied, method, although non-invasive methods are keenly required in evaluating TEMPs. The results showed that: (a) the coefficient of variation (CV) of the measured sGAG contents in intralaboratory tests was ~5% at most; (b) the CV of sGAG content in the scheme where each participating laboratory measured different constructs was comparable with that in the scheme where each participating laboratory measured one half of a construct along with the organizing laboratory; (c) the CV caused by factors other than the specimen was ~15%, comparable to that in reproducible experiments in biomedical fields. Based on these results, the study concludes that a round robin test for a TEMP could be valuable, under the condition that the delivered TEMPs are sufficiently reproducible so that the CV of the measured values is < 5% in the organizing laboratory. Copyright © 2011 John Wiley & Sons, Ltd.

  20. Ventricular fractional shortening in 108 dogs with malignant lymphoma undergoing chemotherapy with a cyclic combination protocol including doxorubicin.

    PubMed

    Tater, G; Eberle, N; Hungerbuehler, S; Joetzke, A; Nolte, I; Wess, G; Betz, D

    2012-01-01

    The aim of this study was to evaluate whether changes in the left ventricular fractional shortening (LVFS) can be detected in dogs with malignant lymphoma undergoing a cyclic combination chemotherapy protocol including doxorubicin. Left ventricular fractional shortening as a stand-alone measurement will not show a significant change during the cyclic combination protocol. In this retrospective study, the records of dogs with malignant lymphoma treated between April 2001 and October 2010 were reviewed. Inclusion criteria comprised: a diagnosis of malignant lymphoma, a cyclic combination chemotherapy (including L-asparaginase, vincristine, cyclophosphamide, doxorubicin and prednisolone), and an echocardiographic examination by an experienced examiner before treatment and after each doxorubicin administration. One hundred and eight dogs were included and a total of 446 LVFS measurements had been performed. Patients were divided into four groups according to the number of doxorubicin administrations. Median LVFS did not change significantly during the cyclic combination protocol in all groups. All median LVFS values remained above the lower reference value of 25%. The measurement of LVFS did not show a significant change during the cyclic combination protocol treatment including doxorubicin in this population of dogs. Therefore either this cyclic combination protocol does not cause a systolic dysfunction or LVFS is not sensitive enough to detect early changes. Newer methods that are more sensitive then LVFS might be necessary to detect such changes.

  1. Objective measurements of excess skin in post bariatric patients--inter-rater reliability.

    PubMed

    Biörserud, Christina; Fagevik Olsén, Monika; Elander, Anna; Wiklund, Malin

    2016-01-01

    An ability to reliably assess excess skin after massive weight loss using well-described and transferrable methods is important. The aim of this trial was to evaluate inter-rater reliability of ptosis and circumference measurements in patients with excess skin after bariatric surgery. Twenty-five postbariatric patients were included in the study, and their excess skin was measured 18 months after surgery. A protocol was designed to measure excess skin in a standardised way. To evaluate the inter-rater reliability in the measuring protocol, all patients were measured twice, by a specialist nurse and a specialist physiotherapist. All circumference measurements on different body parts had an ICC > 0.9, indicating high reliability. Furthermore, all breast and abdominal ptosis measurements had high reliability. In contrast, visual evaluation of abdominal ptosis had poor reliability. Measurements of ptoses on different body parts had an ICC > 0.6. There were no systematic differences between the results of the two testers, except for measurements of the buttocks and maximal knee circumference. The measuring protocol presented in this study has high reliability and, therefore, represents a useful instrument to provide a consistent and objective assessment of excess skin in the postbariatric patient.

  2. Use of the HR index to predict maximal oxygen uptake during different exercise protocols.

    PubMed

    Haller, Jeannie M; Fehling, Patricia C; Barr, David A; Storer, Thomas W; Cooper, Christopher B; Smith, Denise L

    2013-10-01

    This study examined the ability of the HRindex model to accurately predict maximal oxygen uptake ([Formula: see text]O2max) across a variety of incremental exercise protocols. Ten men completed five incremental protocols to volitional exhaustion. Protocols included three treadmill (Bruce, UCLA running, Wellness Fitness Initiative [WFI]), one cycle, and one field (shuttle) test. The HRindex prediction equation (METs = 6 × HRindex - 5, where HRindex = HRmax/HRrest) was used to generate estimates of energy expenditure, which were converted to body mass-specific estimates of [Formula: see text]O2max. Estimated [Formula: see text]O2max was compared with measured [Formula: see text]O2max. Across all protocols, the HRindex model significantly underestimated [Formula: see text]O2max by 5.1 mL·kg(-1)·min(-1) (95% CI: -7.4, -2.7) and the standard error of the estimate (SEE) was 6.7 mL·kg(-1)·min(-1). Accuracy of the model was protocol-dependent, with [Formula: see text]O2max significantly underestimated for the Bruce and WFI protocols but not the UCLA, Cycle, or Shuttle protocols. Although no significant differences in [Formula: see text]O2max estimates were identified for these three protocols, predictive accuracy among them was not high, with root mean squared errors and SEEs ranging from 7.6 to 10.3 mL·kg(-1)·min(-1) and from 4.5 to 8.0 mL·kg(-1)·min(-1), respectively. Correlations between measured and predicted [Formula: see text]O2max were between 0.27 and 0.53. Individual prediction errors indicated that prediction accuracy varied considerably within protocols and among participants. In conclusion, across various protocols the HRindex model significantly underestimated [Formula: see text]O2max in a group of aerobically fit young men. Estimates generated using the model did not differ from measured [Formula: see text]O2max for three of the five protocols studied; nevertheless, some individual prediction errors were large. The lack of precision among estimates may limit the utility of the HRindex model; however, further investigation to establish the model's predictive accuracy is warranted.

  3. Evaluating anesthetic protocols for functional blood flow imaging in the rat eye

    NASA Astrophysics Data System (ADS)

    Moult, Eric M.; Choi, WooJhon; Boas, David A.; Baumann, Bernhard; Clermont, Allen C.; Feener, Edward P.; Fujimoto, James G.

    2017-01-01

    The purpose of this study is to evaluate the suitability of five different anesthetic protocols (isoflurane, isoflurane-xylazine, pentobarbital, ketamine-xylazine, and ketamine-xylazine-vecuronium) for functional blood flow imaging in the rat eye. Total retinal blood flow was measured at a series of time points using an ultrahigh-speed Doppler OCT system. Additionally, each anesthetic protocol was qualitatively evaluated according to the following criteria: (1) time-stability of blood flow, (2) overall rate of blood flow, (3) ocular immobilization, and (4) simplicity. We observed that different anesthetic protocols produced markedly different blood flows. Different anesthetic protocols also varied with respect to the four evaluated criteria. These findings suggest that the choice of anesthetic protocol should be carefully considered when designing and interpreting functional blood flow studies in the rat eye.

  4. A harmonized segmentation protocol for hippocampal and parahippocampal subregions: why do we need one and what are the key goals?

    PubMed Central

    Olsen, Rosanna K.; Berron, David; Carr, Valerie A.; Stark, Craig E.L.; Amaral, Robert S.C.; Amunts, Katrin; Augustinack, Jean C.; Bender, Andrew R.; Bernstein, Jeffrey D.; Boccardi, Marina; Bocchetta, Martina; Burggren, Alison; Chakravarty, M. Mallar; Chupin, Marie; Ekstrom, Arne; de Flores, Robin; Insausti, Ricardo; Kanel, Prabesh; Kedo, Olga; Kennedy, Kristen M.; Kerchner, Geoffrey A.; LaRocque, Karen F.; Liu, Xiuwen; Maass, Anne; Malykhin, Nicolai; Mueller, Susanne G.; Ofen, Noa; Palombo, Daniela J.; Parekh, Mansi B.; Pluta, John B.; Pruessner, Jens C.; Raz, Naftali; Rodrigue, Karen M.; Schoemaker, Dorothee; Shafer, Andrea T.; Steve, Trevor A.; Suthana, Nanthia; Wang, Lei; Winterburn, Julie L.; Yassa, Michael A.; Yushkevich, Paul A.; la Joie, Renaud

    2016-01-01

    The advent of high-resolution magnetic resonance imaging (MRI) has enabled in vivo research in a variety of populations and diseases on the structure and function of hippocampal subfields and subdivisions of the parahippocampal gyrus. Due to the many extant and highly discrepant segmentation protocols, comparing results across studies is difficult. To overcome this barrier, the Hippocampal Subfields Group was formed as an international collaboration with the aim of developing a harmonized protocol for manual segmentation of hippocampal and parahippocampal subregions on high-resolution MRI. In this commentary we discuss the goals for this protocol and the associated key challenges involved in its development. These include differences among existing anatomical reference materials, striking the right balance between reliability of measurements and anatomical validity, and the development of a versatile protocol that can be adopted for the study of populations varying in age and health. The commentary outlines these key challenges, as well as the proposed solution of each, with concrete examples from our working plan. Finally, with two examples, we illustrate how the harmonized protocol, once completed, is expected to impact the field by producing measurements that are quantitatively comparable across labs and by facilitating the synthesis of findings across different studies. PMID:27862600

  5. Permissive weight bearing in trauma patients with fracture of the lower extremities: prospective multicenter comparative cohort study.

    PubMed

    Kalmet, Pishtiwan H S; Meys, Guido; V Horn, Yvette Y; Evers, Silvia M A A; Seelen, Henk A M; Hustinx, Paul; Janzing, Heinrich; Vd Veen, Alexander; Jaspars, Coen; Sintenie, Jan Bernard; Blokhuis, Taco J; Poeze, Martijn; Brink, Peter R G

    2018-02-02

    The standard aftercare treatment in surgically treated trauma patients with fractures around or in a joint, known as (peri)- or intra-articular fractures of the lower extremities, is either non-weight bearing or partial weight bearing. We have developed an early permissive weight bearing post-surgery rehabilitation protocol in surgically treated patients with fractures of the lower extremities. In this proposal we want to compare our early permissive weight bearing protocol to the existing current non-weight bearing guidelines in a prospective comparative cohort study. The study is a prospective multicenter comparative cohort study in which two rehabilitation aftercare treatments will be contrasted, i.e. permissive weight bearing and non-weight bearing according to the AO-guideline. The study population consists of patients with a surgically treated fracture of the pelvis/acetabulum or a surgically treated (peri)- or intra-articular fracture of the lower extremities. The inclusion period is 12 months. The duration of follow up is 6 months, with measurements taken at baseline, 2,6,12 and 26 weeks post-surgery. ADL with Lower Extremity Functional Scale. Outcome variables for compliance, as measured with an insole pressure measurement system, encompass peak load and step duration. This study will investigate the (cost-) effectiveness of a permissive weight bearing aftercare protocol. The results will provide evidence whether a permissive weight bearing protocol is more effective than the current non-weight bearing protocol. The study is registered in the Dutch Trial Register ( NTR6077 ). Date of registration: 01-09-2016.

  6. Quantum-key-distribution protocol with pseudorandom bases

    NASA Astrophysics Data System (ADS)

    Trushechkin, A. S.; Tregubov, P. A.; Kiktenko, E. O.; Kurochkin, Y. V.; Fedorov, A. K.

    2018-01-01

    Quantum key distribution (QKD) offers a way for establishing information-theoretical secure communications. An important part of QKD technology is a high-quality random number generator for the quantum-state preparation and for post-processing procedures. In this work, we consider a class of prepare-and-measure QKD protocols, utilizing additional pseudorandomness in the preparation of quantum states. We study one of such protocols and analyze its security against the intercept-resend attack. We demonstrate that, for single-photon sources, the considered protocol gives better secret key rates than the BB84 and the asymmetric BB84 protocols. However, the protocol strongly requires single-photon sources.

  7. Very Low Intravenous Contrast Volume Protocol for Computed Tomography Angiography Providing Comprehensive Cardiac and Vascular Assessment Prior to Transcatheter Aortic Valve Replacement in Patients with Chronic Kidney Disease

    PubMed Central

    Pulerwitz, Todd C.; Khalique, Omar K.; Nazif, Tamim N.; Rozenshtein, Anna; Pearson, Gregory D.N.; Hahn, Rebecca T.; Vahl, Torsten P.; Kodali, Susheel K.; George, Isaac; Leon, Martin B.; D'Souza, Belinda; Po, Ming Jack; Einstein, Andrew J.

    2016-01-01

    Background Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable. Methods 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30mL/min) who underwent a novel VLCV protocol (20mL of iohexol at 2.5mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale. Results VLCV patients had mean(±SD) age 86±6.5, BMI 23.9±3.4 kg/m2 with 54% men; SCV patients age 83±8.8, BMI 28.7±5.3 kg/m2, 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement. Conclusions This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment. PMID:27061253

  8. The Test Matters: The Relationship between Classroom Observation Scores and Teacher Value Added on Multiple Types of Assessment

    ERIC Educational Resources Information Center

    Grossman, Pam; Cohen, Julie; Ronfeldt, Matthew; Brown, Lindsay

    2014-01-01

    In this study, we examined how the relationships between one observation protocol, the Protocol for Language Arts Teaching Observation (PLATO), and value-added measures shift when different tests are used to assess student achievement. Using data from the Measures of Effective Teaching Project, we found that PLATO was more strongly related to the…

  9. An in silico method to identify computer-based protocols worthy of clinical study: An insulin infusion protocol use case

    PubMed Central

    Wong, Anthony F; Pielmeier, Ulrike; Haug, Peter J; Andreassen, Steen

    2016-01-01

    Objective Develop an efficient non-clinical method for identifying promising computer-based protocols for clinical study. An in silico comparison can provide information that informs the decision to proceed to a clinical trial. The authors compared two existing computer-based insulin infusion protocols: eProtocol-insulin from Utah, USA, and Glucosafe from Denmark. Materials and Methods The authors used eProtocol-insulin to manage intensive care unit (ICU) hyperglycemia with intravenous (IV) insulin from 2004 to 2010. Recommendations accepted by the bedside clinicians directly link the subsequent blood glucose values to eProtocol-insulin recommendations and provide a unique clinical database. The authors retrospectively compared in silico 18 984 eProtocol-insulin continuous IV insulin infusion rate recommendations from 408 ICU patients with those of Glucosafe, the candidate computer-based protocol. The subsequent blood glucose measurement value (low, on target, high) was used to identify if the insulin recommendation was too high, on target, or too low. Results Glucosafe consistently provided more favorable continuous IV insulin infusion rate recommendations than eProtocol-insulin for on target (64% of comparisons), low (80% of comparisons), or high (70% of comparisons) blood glucose. Aggregated eProtocol-insulin and Glucosafe continuous IV insulin infusion rates were clinically similar though statistically significantly different (Wilcoxon signed rank test P = .01). In contrast, when stratified by low, on target, or high subsequent blood glucose measurement, insulin infusion rates from eProtocol-insulin and Glucosafe were statistically significantly different (Wilcoxon signed rank test, P < .001), and clinically different. Discussion This in silico comparison appears to be an efficient nonclinical method for identifying promising computer-based protocols. Conclusion Preclinical in silico comparison analytical framework allows rapid and inexpensive identification of computer-based protocol care strategies that justify expensive and burdensome clinical trials. PMID:26228765

  10. A tonic heat test stimulus yields a larger and more reliable conditioned pain modulation effect compared to a phasic heat test stimulus

    PubMed Central

    Lie, Marie Udnesseter; Matre, Dagfinn; Hansson, Per; Stubhaug, Audun; Zwart, John-Anker; Nilsen, Kristian Bernhard

    2017-01-01

    Abstract Introduction: The interest in conditioned pain modulation (CPM) as a clinical tool for measuring endogenously induced analgesia is increasing. There is, however, large variation in the CPM methodology, hindering comparison of results across studies. Research comparing different CPM protocols is needed in order to obtain a standardized test paradigm. Objectives: The aim of the study was to assess whether a protocol with phasic heat stimuli as test-stimulus is preferable to a protocol with tonic heat stimulus as test-stimulus. Methods: In this experimental crossover study, we compared 2 CPM protocols with different test-stimulus; one with tonic test-stimulus (constant heat stimulus of 120-second duration) and one with phasic test-stimuli (3 heat stimulations of 5 seconds duration separated by 10 seconds). Conditioning stimulus was a 7°C water bath in parallel with the test-stimulus. Twenty-four healthy volunteers were assessed on 2 occasions with minimum 1 week apart. Differences in the magnitude and test–retest reliability of the CPM effect in the 2 protocols were investigated with repeated-measures analysis of variance and by relative and absolute reliability indices. Results: The protocol with tonic test-stimulus induced a significantly larger CPM effect compared to the protocol with phasic test-stimuli (P < 0.001). Fair and good relative reliability was found with the phasic and tonic test-stimuli, respectively. Absolute reliability indices showed large intraindividual variability from session to session in both protocols. Conclusion: The present study shows that a CPM protocol with a tonic test-stimulus is preferable to a protocol with phasic test-stimuli. However, we emphasize that one should be cautious to use the CPM effect as biomarker or in clinical decision making on an individual level due to large intraindividual variability. PMID:29392240

  11. On entropy determination from magnetic and calorimetric experiments in conventional giant magnetocaloric materials

    NASA Astrophysics Data System (ADS)

    Chen, Jing-Han; Us Saleheen, Ahmad; Adams, Philip W.; Young, David P.; Ali, Naushad; Stadler, Shane

    2018-04-01

    In this work, we discuss measurement protocols for the determination of the magnetic entropy change associated with first-order magneto-structural transitions from both magnetization and calorimetric experiments. The Cu-doped Ni2MnGa Heusler alloy with a first-order magneto-structural phase transition is used as a case study to illustrate how commonly-used magnetization measurement protocols result in spurious entropy evaluations. Two magnetization measurement protocols which allow for the accurate assessment of the magnetic entropy change across first-order magneto-structural transitions are presented. In addition, calorimetric measurements were performed to validate the results from the magnetization measurements. Self-consistent results between the magnetization and calorimetric measurements were obtained when the non-equilibrium thermodynamic state was carefully handled. Such methods could be applicable to other systems displaying giant magnetocaloric effects caused by first-order phase transitions with magnetic and thermal hysteresis.

  12. The cumulative effect of multiple critical care protocols on length of stay in a geriatric trauma population.

    PubMed

    Frederickson, Tiffany A; Renner, Catherine Hackett; Swegle, James R; Sahr, Sheryl M

    2013-01-01

    The elderly individuals are the most rapidly growing cohort within the US population, and a corresponding increase is being seen in elderly trauma patients. Elderly patients are more likely to have a hospital length of stay (LOS) in excess of 10 days. They account for 60% of total ICU days. Length of stay is frequently used as a proxy measure for improvement in injury outcomes, changes in quality of care, and hospital outcomes. Patient care protocols are typically created from evidence-based guidelines that serve to reduce variation in care from patient to patient. Patient care protocols have been found to positively impact patient care with reduced duration of mechanical ventilation, shorter LOS in the ICU and shorter overall hospitalization time, reduced mortality, and reduced health care costs. The following study was designed to assess the impact of the implementation of 4 patient care protocols within an elderly trauma population. We hypothesized that the implementation of these protocols would have a beneficial impact on patient care that could be measured by a decrease in hospital LOS. An archival, retrospective pretest/posttest study was performed on elderly trauma patients. The new protocols helped guide practical changes in care that resulted in a 32% decrease in LOS for our elderly trauma patients which exceeds the 25% decrease found in other studies. Additionally, the "Other" category for each variable was less frequently used in the post-protocol phase than in the pre-protocol phase, suggesting a spillover effect on the level of detail recorded in the patient chart. With less variation in practices in the post-protocol phase, Injury Severity score, and admission systolic blood pressure emerged as significant predictors of LOS.

  13. Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement.

    PubMed

    Liu, Jun; Wilson, John; Davis, Claire; Peyton, Anthony

    2017-11-07

    This paper elaborates the sample preparation protocols required to obtain optimal domain patterns using the Bitter method, focusing on the extra steps compared to standard metallographic sample preparation procedures. The paper proposes a novel bespoke rig for dynamic domain imaging with in situ BH (magnetic hysteresis) measurements and elaborates the protocols for the sensor preparation and the use of the rig to ensure accurate BH measurement. The protocols for static and ordinary dynamic domain imaging (without in situ BH measurements) are also presented. The reported method takes advantage of the convenience and high sensitivity of the traditional Bitter method and enables in situ BH measurement without interrupting or interfering with the domain wall movement processes. This facilitates establishing a direct and quantitative link between the domain wall movement processes-microstructural feature interactions in ferritic steels with their BH loops. This method is anticipated to become a useful tool for the fundamental study of microstructure-magnetic property relationships in steels and to help interpret the electromagnetic sensor signals for non-destructive evaluation of steel microstructures.

  14. Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement

    PubMed Central

    Liu, Jun; Wilson, John; Davis, Claire; Peyton, Anthony

    2017-01-01

    This paper elaborates the sample preparation protocols required to obtain optimal domain patterns using the Bitter method, focusing on the extra steps compared to standard metallographic sample preparation procedures. The paper proposes a novel bespoke rig for dynamic domain imaging with in situ BH (magnetic hysteresis) measurements and elaborates the protocols for the sensor preparation and the use of the rig to ensure accurate BH measurement. The protocols for static and ordinary dynamic domain imaging (without in situ BH measurements) are also presented. The reported method takes advantage of the convenience and high sensitivity of the traditional Bitter method and enables in situ BH measurement without interrupting or interfering with the domain wall movement processes. This facilitates establishing a direct and quantitative link between the domain wall movement processes–microstructural feature interactions in ferritic steels with their BH loops. This method is anticipated to become a useful tool for the fundamental study of microstructure–magnetic property relationships in steels and to help interpret the electromagnetic sensor signals for non-destructive evaluation of steel microstructures. PMID:29155796

  15. Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Crawford, Aladsair J.; Viswanathan, Vilayanur V.

    2014-06-01

    The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Its subsequent use in the field and review by the protocol working group and most importantly the users’ subgroup and the thermal subgroup has led to the fundamental modifications reflected in this update of the 2012 Protocol. As an update of the 2012 Protocol, this document (the June 2014 Protocol) is intended to supersedemore » its predecessor and be used as the basis for measuring and expressing ESS performance. The foreword provides general and specific details about what additions, revisions, and enhancements have been made to the 2012 Protocol and the rationale for them in arriving at the June 2014 Protocol.« less

  16. Optimal and secure measurement protocols for quantum sensor networks

    NASA Astrophysics Data System (ADS)

    Eldredge, Zachary; Foss-Feig, Michael; Gross, Jonathan A.; Rolston, S. L.; Gorshkov, Alexey V.

    2018-04-01

    Studies of quantum metrology have shown that the use of many-body entangled states can lead to an enhancement in sensitivity when compared with unentangled states. In this paper, we quantify the metrological advantage of entanglement in a setting where the measured quantity is a linear function of parameters individually coupled to each qubit. We first generalize the Heisenberg limit to the measurement of nonlocal observables in a quantum network, deriving a bound based on the multiparameter quantum Fisher information. We then propose measurement protocols that can make use of Greenberger-Horne-Zeilinger (GHZ) states or spin-squeezed states and show that in the case of GHZ states the protocol is optimal, i.e., it saturates our bound. We also identify nanoscale magnetic resonance imaging as a promising setting for this technology.

  17. Fall risk screening protocol for older hearing clinic patients.

    PubMed

    Criter, Robin E; Honaker, Julie A

    2017-10-01

    The primary purposes of this study were (1) to describe measures that may contrast audiology patients who fall from those who do not fall and (2) to evaluate the clinical performance of measures that could be easily used for fall risk screening in a mainstream audiology hearing clinic. Cross-sectional study Study sample: Thirty-six community-dwelling audiology patient participants and 27 community-dwelling non-audiology patients over 60 years of age. The Hearing Handicap Inventory for the Elderly (HHIE) most accurately identified patients with a recent fall (sensitivity: 76.0%), while the Dizziness Handicap Inventory (DHI) most accurately identified patients without a recent fall (specificity: 90.9%). A combination of measures used in a protocol-including HHIE, DHI, number of medications, and the Timed Up and Go test-resulted in good, accurate identification of patients with or without a recent history of falls (92.0% sensitivity, 100% specificity). This study reports good sensitivity and excellent specificity for identifying patients with and without a recent history of falls when measures were combined into a screening protocol. Despite previously reported barriers, effective fall risk screenings may be performed in hearing clinic settings with measures often readily accessible to audiologists.

  18. Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.

    PubMed

    Stergiou, George S; Asmar, Roland; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Shennan, Andrew; Wang, Jiguang; O'Brien, Eoin

    2018-03-01

    The European Society of Hypertension (ESH) International Protocol (ESH-IP) for the validation of blood pressure (BP) measuring devices was published in 2002, with the main objective of simplifying the validation procedures, so that more BP monitors would be subjected to independent validation. This article provides an overview of the international impact of the ESH-IP and of the lessons learned from its use, to be able to justify further developments in validation protocols. A review of published (PubMed) validation studies from 2002 to 2017 was performed. One hundred and seventy-seven validation studies using the ESH-IP, 59 using the British Hypertension Society protocol, 46 using the Association for the Advancement of Medical Instrumentation (AAMI) standard and 23 using the International Organization for Standardization (ISO) standard were identified. Lists of validated office-clinic, home and ambulatory BP monitors are provided. Of the ESH-IP studies, 93% tested oscillometric devices, 80% upper arm, 71% home, 25% office and 7% ambulatory monitors (some had more than one function). The original goal of the ESH-IP has been fulfilled in that in the last decade the number of published validation studies has more than doubled. It is now recognized that the provision of accurate devices would be best served by having a universal protocol. An international initiative has been put in place by AAMI, ESH and ISO experts aiming to reach consensus for a universal validation protocol to be accepted worldwide, which will allow a more thorough evaluation of the accuracy and performance of future BP monitors.

  19. Finite-size analysis of continuous-variable measurement-device-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Zhang, Xueying; Zhang, Yichen; Zhao, Yijia; Wang, Xiangyu; Yu, Song; Guo, Hong

    2017-10-01

    We study the impact of the finite-size effect on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, mainly considering the finite-size effect on the parameter estimation procedure. The central-limit theorem and maximum likelihood estimation theorem are used to estimate the parameters. We also analyze the relationship between the number of exchanged signals and the optimal modulation variance in the protocol. It is proved that when Charlie's position is close to Bob, the CV-MDI QKD protocol has the farthest transmission distance in the finite-size scenario. Finally, we discuss the impact of finite-size effects related to the practical detection in the CV-MDI QKD protocol. The overall results indicate that the finite-size effect has a great influence on the secret-key rate of the CV-MDI QKD protocol and should not be ignored.

  20. Bidirectional Teleportation Protocol in Quantum Wireless Multi-hop Network

    NASA Astrophysics Data System (ADS)

    Cai, Rui; Yu, Xu-Tao; Zhang, Zai-Chen

    2018-06-01

    We propose a bidirectional quantum teleportation protocol based on a composite GHZ-Bell state. In this protocol, the composite GHZ-Bell state channel is transformed into two-Bell state channel through gate operations and single qubit measurements. The channel transformation will lead to different kinds of quantum channel states, so a method is proposed to help determine the unitary matrices effectively under different quantum channels. Furthermore, we discuss the bidirectional teleportation protocol in the quantum wireless multi-hop network. This paper is aimed to provide a bidirectional teleportation protocol and study the bidirectional multi-hop teleportation in the quantum wireless communication network.

  1. Bidirectional Teleportation Protocol in Quantum Wireless Multi-hop Network

    NASA Astrophysics Data System (ADS)

    Cai, Rui; Yu, Xu-Tao; Zhang, Zai-Chen

    2018-02-01

    We propose a bidirectional quantum teleportation protocol based on a composite GHZ-Bell state. In this protocol, the composite GHZ-Bell state channel is transformed into two-Bell state channel through gate operations and single qubit measurements. The channel transformation will lead to different kinds of quantum channel states, so a method is proposed to help determine the unitary matrices effectively under different quantum channels. Furthermore, we discuss the bidirectional teleportation protocol in the quantum wireless multi-hop network. This paper is aimed to provide a bidirectional teleportation protocol and study the bidirectional multi-hop teleportation in the quantum wireless communication network.

  2. The Acute Effects of Static Stretching Compared to Dynamic Stretching with and without an Active Warm up on Anaerobic Performance

    PubMed Central

    KENDALL, BRADLEY J.

    2017-01-01

    The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F(4,36) = 3.90, p = .01, partial η2 = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies. PMID:28479947

  3. The Acute Effects of Static Stretching Compared to Dynamic Stretching with and without an Active Warm up on Anaerobic Performance.

    PubMed

    Kendall, Bradley J

    2017-01-01

    The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F (4,36) = 3.90, p = .01, partial η 2 = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies.

  4. Security of two-state and four-state practical quantum bit-commitment protocols

    NASA Astrophysics Data System (ADS)

    Loura, Ricardo; Arsenović, Dušan; Paunković, Nikola; Popović, Duška B.; Prvanović, Slobodan

    2016-12-01

    We study cheating strategies against a practical four-state quantum bit-commitment protocol [A. Danan and L. Vaidman, Quant. Info. Proc. 11, 769 (2012)], 10.1007/s11128-011-0284-4 and its two-state variant [R. Loura et al., Phys. Rev. A 89, 052336 (2014)], 10.1103/PhysRevA.89.052336 when the underlying quantum channels are noisy and the cheating party is constrained to using single-qubit measurements only. We show that simply inferring the transmitted photons' states by using the Breidbart basis, optimal for ambiguous (minimum-error) state discrimination, does not directly produce an optimal cheating strategy for this bit-commitment protocol. We introduce a strategy, based on certain postmeasurement processes and show it to have better chances at cheating than the direct approach. We also study to what extent sending forged geographical coordinates helps a dishonest party in breaking the binding security requirement. Finally, we investigate the impact of imperfect single-photon sources in the protocols. Our study shows that, in terms of the resources used, the four-state protocol is advantageous over the two-state version. The analysis performed can be straightforwardly generalized to any finite-qubit measurement, with the same qualitative results.

  5. SU-E-J-19: An Intra-Institutional Study of Cone-Beam CT Dose for Image-Guided Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knutson, N; Present Address: Mount Sinai Roosevelt Hospital, New York, NY; Rankine, L

    2015-06-15

    Purpose: To determine the variability of Cone-Beam CT Dose Index (CB-CTDI) across multiple on-board imaging (OBI) systems within a single institution, and compare this to manufacturer provided data. Methods: The CB-CTDI was measured on three Trilogy and three TrueBeam Varian OBI systems, for six different clinically used scan protocols. Measurements were taken using a 10 cm long CT ionization chamber in either a 16 cm (head-simulating) or 32 cm (body-simulating) diameter, acrylic, cylindrical, 15 cm long CTDI phantom. We assessed the variation in CB-CTDI between the OBI systems and compared our measured values to the data provided by the manufacturer.more » Results: The standard error in the CB-CTDI measured for all protocols was found to be within ±2% and ±5% of the mean for TrueBeam and Trilogy, respectively. For all head scan protocols, the measured TrueBeam values were lower than the manufacturer’s reported values, with a maximum difference of 13.9% and an average difference of 11%. For the body scan protocols, the TrueBeam measured values were 3% and 13% greater than the manufacturer’s reported values for two out of three protocols, and 38% lower than reported for the third protocol. In total, 7/18 CB-CTDI measurements fell within the manufacturers specified range (±10%). Across all scans the Truebeam machines were found to have a lower CB-CTDI than Trilogy, particularly the head scan protocols, which show decreases of up to 30% . Conclusion: The intra-institutional variation of CB-CTDI was found to be clinically acceptable at less than 5%. For the TrueBeam OBI system, over half of the measured scans failed to fall with in the manufactured quoted range of 10%, however, all measured values were within 15% of the manufacturer’s reported values. For accurate assessment and reporting of imaging dose to radiotherapy patients, our results indicate a need for standardization in CB-CTDI measurement technique.« less

  6. A kind of universal quantum secret sharing protocol

    NASA Astrophysics Data System (ADS)

    Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian

    2017-01-01

    Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix.

  7. A kind of universal quantum secret sharing protocol.

    PubMed

    Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian

    2017-01-12

    Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix.

  8. A kind of universal quantum secret sharing protocol

    PubMed Central

    Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian

    2017-01-01

    Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix. PMID:28079109

  9. A framework for the definition of standardized protocols for measuring upper-extremity kinematics.

    PubMed

    Kontaxis, A; Cutti, A G; Johnson, G R; Veeger, H E J

    2009-03-01

    Increasing interest in upper extremity biomechanics has led to closer investigations of both segment movements and detailed joint motion. Unfortunately, conceptual and practical differences in the motion analysis protocols used up to date reduce compatibility for post data and cross validation analysis and so weaken the body of knowledge. This difficulty highlights a need for standardised protocols, each addressing a set of questions of comparable content. The aim of this work is therefore to open a discussion and propose a flexible framework to support: (1) the definition of standardised protocols, (2) a standardised description of these protocols, and (3) the formulation of general recommendations. Proposal of a framework for the definition of standardized protocols. The framework is composed by two nested flowcharts. The first defines what a motion analysis protocol is by pointing out its role in a motion analysis study. The second flowchart describes the steps to build a protocol, which requires decisions on the joints or segments to be investigated and the description of their mechanical equivalent model, the definition of the anatomical or functional coordinate frames, the choice of marker or sensor configuration and the validity of their use, the definition of the activities to be measured and the refinements that can be applied to the final measurements. Finally, general recommendations are proposed for each of the steps based on the current literature, and open issues are highlighted for future investigation and standardisation. Standardisation of motion analysis protocols is urgent. The proposed framework can guide this process through the rationalisation of the approach.

  10. Development of a method for the characterization and operation of UV-LED for water treatment.

    PubMed

    Kheyrandish, Ataollah; Mohseni, Madjid; Taghipour, Fariborz

    2017-10-01

    Tremendous improvements in semiconductor technology have made ultraviolet light-emitting diodes (UV-LEDs) a viable alternative to conventional UV sources for water treatment. A robust and validated experimental protocol for studying the kinetics of microorganism inactivation is key to the further development of UV-LEDs for water treatment. This study proposes a protocol to operate UV-LEDs and control their output as a polychromatic radiation source. In order to systematically develop this protocol, the results of spectral power distribution, radiation profile, and radiant power measurements of a variety of UV-LEDs are presented. A wide range of UV-LEDs was selected for this study, covering various UVA, UVB, and UVC wavelengths, viewing angles from 3.5° to 135°, and a variety of output powers. The effects of operational conditions and measurement techniques were investigated on these UV-LEDs using a specially designed and fabricated setup. Operating conditions, such as the UV-LED electrical current and solder temperature, were found to significantly affect the power and peak wavelength output. The measurement techniques and equipment, including the detector size, detector distance from the UV-LED, and potential reflection from the environment, were shown to influence the results for many of the UV-LEDs. The results obtained from these studies were analyzed and applied to the development of a protocol for UV-LED characterization. This protocol is presented as a guideline that allows the operation and control of UV-LEDs in any structure, as well as accurately measuring the UV-LED output. Such information is essential for performing a reliable UV-LED assessment for the inactivation of microorganisms and for obtaining precise kinetic data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. The usefulness and reliability of fitness testing protocols for ice hockey players: a literature review.

    PubMed

    Nightingale, Steven C; Miller, Stuart; Turner, Anthony

    2013-06-01

    Ice hockey, like most sports, uses fitness testing to assess athletes. This study reviews the current commonly used fitness testing protocols for ice hockey players, discussing their predictive values and reliability. It also discusses a range of less commonly used measures and limitations in current testing protocols. The article concludes with a proposed testing program suitable for ice hockey players.

  12. Coping with Pain in the Motivational Context of Values: Comparison between an Acceptance-Based and a Cognitive Control-Based Protocol

    ERIC Educational Resources Information Center

    Paez-Blarrina, Marisa; Luciano, Carmen; Gutierrez-Martinez, Olga; Valdivia, Sonsoles; Rodriguez-Valverde, Miguel; Ortega, Jose

    2008-01-01

    This study compares the effect of an acceptance-based protocol (ACT) and a cognitive control-based (CONT) protocol on three measures of pain coping: tolerance, self-report, and believability. Specific methodological controls were employed to further isolate the role of the value of participating in a pain task, compared to previous investigations…

  13. Study of accent-based music speech protocol development for improving voice problems in stroke patients with mixed dysarthria.

    PubMed

    Kim, Soo Ji; Jo, Uiri

    2013-01-01

    Based on the anatomical and functional commonality between singing and speech, various types of musical elements have been employed in music therapy research for speech rehabilitation. This study was to develop an accent-based music speech protocol to address voice problems of stroke patients with mixed dysarthria. Subjects were 6 stroke patients with mixed dysarthria and they received individual music therapy sessions. Each session was conducted for 30 minutes and 12 sessions including pre- and post-test were administered for each patient. For examining the protocol efficacy, the measures of maximum phonation time (MPT), fundamental frequency (F0), average intensity (dB), jitter, shimmer, noise to harmonics ratio (NHR), and diadochokinesis (DDK) were compared between pre and post-test and analyzed with a paired sample t-test. The results showed that the measures of MPT, F0, dB, and sequential motion rates (SMR) were significantly increased after administering the protocol. Also, there were statistically significant differences in the measures of shimmer, and alternating motion rates (AMR) of the syllable /K$\\inve$/ between pre- and post-test. The results indicated that the accent-based music speech protocol may improve speech motor coordination including respiration, phonation, articulation, resonance, and prosody of patients with dysarthria. This suggests the possibility of utilizing the music speech protocol to maximize immediate treatment effects in the course of a long-term treatment for patients with dysarthria.

  14. GUIDANCE FOR RESEARCH HOUSE STUDIES OF THE FLORIDA RADON RESEARCH PROGRAM, VOLUME 2: MODEL-BACKED EXPERIMENTAL PROTOCOL FOR DETERMINING RADON

    EPA Science Inventory

    The report provides guidance and a readily available reference to groups involved with the Florida Radon Research Program's (FRRP's) research house studies. It includes: 1): Lists of Parameters for continuous and periodic high and low resolution measurements; (2) Protocols for c...

  15. A retrospective review of safety using a nursing driven protocol for autonomic dysreflexia in patients with spinal cord injuries.

    PubMed

    Solinsky, Ryan; Svircev, Jelena N; James, Jennifer J; Burns, Stephen P; Bunnell, Aaron E

    2016-11-01

    Autonomic dysreflexia is a potentially life-threatening condition which afflicts a significant proportion of individuals with spinal cord injuries (SCI). To date, the safety and efficacy of several commonly used interventions for this condition have not been studied. A retrospective chart review of the safety of a previously implemented nursing driven inpatient autonomic dysreflexia protocol. Seventy-eight male patients with SCI who experienced autonomic dysreflexia while inpatient at our Veterans Affairs SCI unit over a 3-1/2-year period were included. The safety of a nursing driven protocol utilizing conservative measures, nitroglycerin paste, and oral hydralazine was evaluated. Occurrence of adverse events and relative hypotensive events during all episodes treated with the protocol, and efficacy of attaining target blood pressure for all episodes with protocol adherence and for initial episode experienced by each patient. Four hundred forty-five episodes of autonomic dysreflexia were recorded in the study period, with 92% adherence to the protocol. When the protocol was followed, target blood pressure was achieved for 97.6% of all episodes. Twenty-three total adverse events occurred (5.2% of all episodes). All adverse events were due to hypotension and only 0.9% required interventions beyond clinical monitoring. Of each patient's initial autonomic dysreflexia episode, 97.3% resolved using the protocol without need for further escalation of care. This inpatient nursing driven-protocol for treating autonomic dysreflexia utilizing conservative measures, nitroglycerin paste and oral hydralazine achieved target blood pressure with a high success rate and a low incidence of adverse events.

  16. Risk of bias and confounding of observational studies of Zika virus infection: A scoping review of research protocols.

    PubMed

    Reveiz, Ludovic; Haby, Michelle M; Martínez-Vega, Ruth; Pinzón-Flores, Carlos E; Elias, Vanessa; Smith, Emma; Pinart, Mariona; Broutet, Nathalie; Becerra-Posada, Francisco; Aldighieri, Sylvain; Van Kerkhove, Maria D

    2017-01-01

    Given the severity and impact of the current Zika virus (ZIKV) outbreak in the Americas, numerous countries have rushed to develop research studies to assess ZIKV and its potential health consequences. In an effort to ensure that studies are comprehensive, both internally and externally valid, and with reliable results, the World Health Organization, the Pan American Health Organization, Institut Pasteur, the networks of Fiocruz, the Consortia for the Standardization of Influenza Seroepidemiology (CONSISE) and the International Severe Acute Respiratory and Emerging Infection Consortium (ISARIC) have generated six standardized clinical and epidemiological research protocols and questionnaires to address key public health questions on ZIKV. We conducted a systematic search of ongoing study protocols related to ZIKV research. We analyzed the content of protocols of 32 cohort studies and 13 case control studies for systematic bias that could produce erroneous results. Additionally we aimed to characterize the risks of bias and confounding in observational studies related to ZIKV and to propose ways to minimize them, including the use of six newly standardized research protocols. Observational studies of ZIKV face an array of challenges, including measurement of exposure and outcomes (microcephaly and Guillain-Barré Syndrome). Potential confounders need to be measured where known and controlled for in the analysis. Selection bias due to non-random selection is a significant issue, particularly in the case-control design, and losses to follow-up is equally important for the cohort design. Observational research seeking to answer key questions on the ZIKV should consider these restrictions and take precautions to minimize bias in an effort to provide reliable and valid results. Utilization of the standardized research protocols developed by the WHO, PAHO, Institut Pasteur, and CONSISE will harmonize the key methodological aspects of each study design to minimize bias at different stages of the study. Biases need to be considered by researchers implementing the standardized protocols as well as by users of observational epidemiological studies of ZIKV.

  17. Effects of a Straw Phonation Protocol on Acoustic and Perceptual Measures of an SATB Chorus.

    PubMed

    Manternach, Jeremy N; Daugherty, James F

    2017-12-29

    Recent scholarship has suggested that semi-occluded vocal tract (SOVT) exercises may increase vocal economy of individuals by reducing vocal effort while maintaining or increasing acoustic output. Choral singers, however, may use different resonance techniques or change voicing behaviors in an effort to hear their own sound in relation to others. One investigation revealed significant increases in a choir's mean spectral energy after participating in a straw phonation protocol. However, that study reported only acoustic measures and did not include choristers' perceptions of the choral sound and their own voicing efficiency. The purpose of this study was to measure the effect of a straw phonation protocol on acoustic (long-term average spectrum) and perceptual (self-report) measures of the choral sound of an intact soprano, alto, tenor, and bass (SATB) choir. This is a quasi-experimental, one-group, pretest-posttest design. An SATB choir (N = 48 singers) performed a Renaissance motet, participated in a 4-minute voicing protocol with a small straw, and then sang the motet a second time. They completed the same procedure later in the rehearsal. Long-term average spectrum results indicated no statistically significant mean changes in spectral energy after the SOVT protocols. Most participants, however, perceived that the choir sounded better (78.26%) and that their own vocal production was more efficient or comfortable (73.91%) following the protocol. Choristers perceived less vocal effort while maintaining vocal output after straw phonation, which may feasibly align with extant solo research. More research may determine whether this result is due specifically to SOVTs. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  18. Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol

    PubMed Central

    Hohenauer, Erich; Clarys, Peter; Baeyens, Jean-Pierre; Clijsen, Ron

    2017-01-01

    Fast recovery after strenuous exercise is important in sports and is often studied via cryotherapy applications. Cryotherapy has a significant vasoconstrictive effect, which seems to be the leading factor in its effectiveness. The resulting enhanced recovery can be measured by using both objective and subjective parameters. Two commonly measured subjective characteristics of recovery are delayed-onset muscle soreness (DOMS) and ratings of perceived exertion (RPE). Two important objective recovery characteristics are countermovement jump (CMJ) performance and peak power output (PPO). Here, we provide a detailed protocol to induce muscular exhaustion of the frontal thighs with a self-paced, 3 x 30 countermovement jump protocol (30-s rest between each set). This randomized controlled trial protocol explains how to perform local cryotherapy cuff application (+ 8 °C for 20 min) and thermoneutral cuff application (+ 32 °C for 20 min) on both thighs as two possible post-exercise recovery modalities. Finally, we provide a non-invasive protocol to measure the effects of these two recovery modalities on subjective (i.e., DOMS of both frontal thighs and RPE) and objective recovery (i.e., CMJ and PPO) characteristics 24, 48, and 72 h post-application. The advantage of this method is that it provides a tool for researchers or coaches to induce muscular exhaustion, without using any expensive devices; to implement local cooling strategies; and to measure both subjective and objective recovery, without using invasive methods. Limitations of this protocol are that the 30 s rest period between sets is very short, and the cardiovascular demand is very high. Future studies may find the assessment of maximum voluntary contractions to be a more sensitive assessment of muscular exhaustion compared to CMJs. PMID:28654037

  19. A harmonized segmentation protocol for hippocampal and parahippocampal subregions: Why do we need one and what are the key goals?

    PubMed

    Wisse, Laura E M; Daugherty, Ana M; Olsen, Rosanna K; Berron, David; Carr, Valerie A; Stark, Craig E L; Amaral, Robert S C; Amunts, Katrin; Augustinack, Jean C; Bender, Andrew R; Bernstein, Jeffrey D; Boccardi, Marina; Bocchetta, Martina; Burggren, Alison; Chakravarty, M Mallar; Chupin, Marie; Ekstrom, Arne; de Flores, Robin; Insausti, Ricardo; Kanel, Prabesh; Kedo, Olga; Kennedy, Kristen M; Kerchner, Geoffrey A; LaRocque, Karen F; Liu, Xiuwen; Maass, Anne; Malykhin, Nicolai; Mueller, Susanne G; Ofen, Noa; Palombo, Daniela J; Parekh, Mansi B; Pluta, John B; Pruessner, Jens C; Raz, Naftali; Rodrigue, Karen M; Schoemaker, Dorothee; Shafer, Andrea T; Steve, Trevor A; Suthana, Nanthia; Wang, Lei; Winterburn, Julie L; Yassa, Michael A; Yushkevich, Paul A; la Joie, Renaud

    2017-01-01

    The advent of high-resolution magnetic resonance imaging (MRI) has enabled in vivo research in a variety of populations and diseases on the structure and function of hippocampal subfields and subdivisions of the parahippocampal gyrus. Because of the many extant and highly discrepant segmentation protocols, comparing results across studies is difficult. To overcome this barrier, the Hippocampal Subfields Group was formed as an international collaboration with the aim of developing a harmonized protocol for manual segmentation of hippocampal and parahippocampal subregions on high-resolution MRI. In this commentary we discuss the goals for this protocol and the associated key challenges involved in its development. These include differences among existing anatomical reference materials, striking the right balance between reliability of measurements and anatomical validity, and the development of a versatile protocol that can be adopted for the study of populations varying in age and health. The commentary outlines these key challenges, as well as the proposed solution of each, with concrete examples from our working plan. Finally, with two examples, we illustrate how the harmonized protocol, once completed, is expected to impact the field by producing measurements that are quantitatively comparable across labs and by facilitating the synthesis of findings across different studies. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Chapter 15: Commercial New Construction Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Keates, Steven

    This protocol is intended to describe the recommended method when evaluating the whole-building performance of new construction projects in the commercial sector. The protocol focuses on energy conservation measures (ECMs) or packages of measures where evaluators can analyze impacts using building simulation. These ECMs typically require the use of calibrated building simulations under Option D of the International Performance Measurement and Verification Protocol (IPMVP).

  1. STANDARD MEASUREMENT PROTOCOLS - FLORIDA RADON RESEARCH PROGRAM

    EPA Science Inventory

    The manual, in support of the Florida Radon Research Program, contains standard protocols for key measurements where data quality is vital to the program. t contains two sections. he first section, soil measurements, contains field sampling protocols for soil gas permeability and...

  2. Clinical outcomes and mortality before and after implementation of a pediatric sepsis protocol in a limited resource setting: A retrospective cohort study in Bangladesh.

    PubMed

    Kortz, Teresa Bleakly; Axelrod, David M; Chisti, Mohammod J; Kache, Saraswati

    2017-01-01

    Pediatric sepsis has a high mortality rate in limited resource settings. Sepsis protocols have been shown to be a cost-effective strategy to improve morbidity and mortality in a variety of populations and settings. At Dhaka Hospital in Bangladesh, mortality from pediatric sepsis in high-risk children previously approached 60%, which prompted the implementation of an evidenced-based protocol in 2010. The clinical effectiveness of this protocol had not been measured. We hypothesized that implementation of a pediatric sepsis protocol improved clinical outcomes, including reducing mortality and length of hospital stay. This was a retrospective cohort study of children 1-59 months old with a diagnosis of sepsis, severe sepsis or septic shock admitted to Dhaka Hospital from 10/25/2009-10/25/2011. The primary outcome was inpatient mortality pre- and post-protocol implementation. Secondary outcomes included fluid overload, heart failure, respiratory insufficiency, length of hospital stay, and protocol compliance, as measured by antibiotic and fluid bolus administration within 60 minutes of hospital presentation. 404 patients were identified by a key-word search of the electronic medical record; 328 patients with a primary diagnosis of sepsis, severe sepsis, or septic shock were included (143 pre- and185 post-protocol) in the analysis. Pre- and post-protocol mortality were similar and not statistically significant (32.17% vs. 34.59%, p = 0.72). The adjusted odds ratio (AOR) for post-protocol mortality was 1.55 (95% CI, 0.88-2.71). The odds for developing fluid overload were significantly higher post-protocol (AOR 3.45, 95% CI, 2.04-5.85), as were the odds of developing heart failure (AOR 4.52, 95% CI, 1.43-14.29) and having a longer median length of stay (AOR 1.81, 95% CI 1.10-2.96). There was no statistically significant difference in respiratory insufficiency (pre- 65.7% vs. post- 70.3%, p = 0.4) or antibiotic administration between the cohorts (pre- 16.08% vs. post- 12.43%, p = 0.42). Implementation of a pediatric sepsis protocol did not improve all-cause mortality or length of stay and may have been associated with increased fluid overload and heart failure during the study period in a large, non-governmental hospital in Bangladesh. Similar rates of early antibiotic administration may indicate poor protocol compliance. Though evidenced-based protocols are a potential cost-effective strategy to improve outcomes, future studies should focus on optimal implementation of context-relevant sepsis protocols in limited resource settings.

  3. A comparative study of two protocols for treadmill walking exercise testing in ambulating subjects with incomplete spinal cord injury.

    PubMed

    Lundgaard, E; Wouda, M F; Strøm, V

    2017-10-01

    This is a comparative study of two exercise testing protocols. The objective of this study was to compare maximal oxygen uptake (VO 2 max) and achieved criteria for maximal exercise testing between the Sunnaas Protocol-a newly designed treadmill exercise test protocol-and the Modified Bruce Protocol in persons with incomplete spinal cord injury (SCI). This study was conducted in Sunnaas Rehabilitation Hospital, Norway. Twenty persons (19 men) with incomplete SCI (AIS D) capable of ambulating without assistive devices performed two treadmill walking exercise tests (Sunnaas Protocol and Modified Bruce Protocol) until exhaustion 1-3 days apart. The key differences between the protocols are the smaller increments in speed and shorter duration on each workload in the Sunnaas Protocol. Cardiovascular responses were measured continuously throughout both tests. The subjects exhibited statistically significantly higher VO 2 max when using the Sunnaas Protocol (37.1±9.9 vs 35.4±9.8 ml kg -1  min -1 , P=0.01), with a mean between-test difference of 1.8 ml kg -1  min -1 (95% confidence interval: 0.49-3.16). There was no significant difference in mean maximal heart rate (HR max). Nineteen (95%) subjects achieved at least three of the four criteria for maximal oxygen uptake using the Sunnaas Protocol. Thirteen (65%) subjects achieved at least three of the criteria using a Modified Bruce protocol. The small differences in both VO 2 max and achieved criteria in favor of the Sunnaas Protocol suggest that it could be a useful alternative treadmill exercise test protocol for ambulating persons with incomplete SCI.

  4. SU-F-J-48: Effect of Scan Length On Magnitude of Imaging Dose in KV CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deshpande, S; Naidu, S; Sutar, A

    Purpose: To study effect of scan length on magnitude of imaging dose deposition in Varian kV CBCT for head & neck and pelvis CBCT. Methods: To study effect of scan length we measured imaging dose at depth of 8 cm for head and neck Cone Beam Computed Tomography (CBCT) acquisition ( X ray beam energy is used 100kV and 200 degree of gantry rotation) and at 16 cm depth for pelvis CBCT acquisition ( X ray beam energy used is 125 kV and 360 degree of gantry rotation) in specially designed phantom. We used farmer chamber which was calibrated inmore » kV X ray range for measurements .Dose was measured with default field size, and reducing field size along y direction to 10 cm and 5 cm. Results: As the energy of the beam decreases the scattered radiation increases and this contributes significantly to the dose deposited in the patient. By reducing the scan length to 10 Cm from default 20.6 cm we found a dose reduction of 14% for head and neck CBCT protocol and a reduction of 26% for pelvis CBCT protocol. Similarly for a scan length of 5cm compared to default the dose reduction in head and neck CBCT protocol is 36% while in the pelvis CBCT protocol the dose reduction is 50%. Conclusion: By limiting the scan length we can control the scatter radiation generated and hence the dose to the patient. However the variation in dose reduction for same length used in two protocols is because of the scan geometry. The pelvis CBCT protocol uses a full rotation and head and neck CBCT protocol uses partial rotation.« less

  5. Validity of Partial Protocols to Assess the Prevalence of Periodontal Outcomes and Associated Sociodemographic and Behavior Factors in Adolescents and Young Adults

    PubMed Central

    Peres, Marco A.; Peres, Karen G.; Cascaes, Andreia M.; Correa, Marcos B.; Demarco, Flávio F.; Hallal, Pedro C.; Horta, Bernardo L.; Gigante, Denise P.; Menezes, Ana B.

    2012-01-01

    Background Most studies comparing prevalence of periodontal disease and risk factors by using partial protocols were performed in adult populations, with several studies being conducted in clinical settings. The aim of this study is to assess the accuracy of partial protocols in estimating the prevalence of periodontal outcomes in adolescents and young adults from two population-based birth cohorts from Pelotas, Brazil, and to assess differences in the estimation and strength of the effect measures when partial protocols are adopted compared to full-mouth examination. Methods Gingival bleeding at probing among adolescents (n = 339) and young adults (n = 720) and dental calculus and periodontal probing depth among young adults were assessed using full-mouth examinations and four partial protocols: Ramfjord teeth (RT), community periodontal index (CPI), and two random diagonal quadrants (1 and 3, 2 and 4). Socioeconomic, demographic, and periodontal health-related variables were also collected. Sensitivity, absolute and relative bias, and inflation factors were calculated. Prevalence ratio for each periodontal outcome for the risk factors was estimated. Results Two diagonal quadrants showed better accuracy; RT had the worst, whereas CPI presented an intermediate pattern when compared to full-mouth examination. For bleeding assessment in adolescence, RT and CPI underestimated by 18.4% and 16.2%, respectively, the true outcome prevalence, whereas among young adults, all partial protocols underestimated the prevalence. All partial protocols presented similar magnitude of association measures for all investigated periodontal potential risk factors. Conclusion Two diagonal quadrants protocol may be effective in identifying the risk factors for the most relevant periodontal outcomes in adolescence and in young adulthood. PMID:21859320

  6. Validity of partial protocols to assess the prevalence of periodontal outcomes and associated sociodemographic and behavior factors in adolescents and young adults.

    PubMed

    Peres, Marco A; Peres, Karen G; Cascaes, Andreia M; Correa, Marcos B; Demarco, Flávio F; Hallal, Pedro C; Horta, Bernardo L; Gigante, Denise P; Menezes, Ana B

    2012-03-01

    Most studies comparing prevalence of periodontal disease and risk factors by using partial protocols were performed in adult populations, with several studies being conducted in clinical settings. The aim of this study is to assess the accuracy of partial protocols in estimating the prevalence of periodontal outcomes in adolescents and young adults from two population-based birth cohorts from Pelotas, Brazil, and to assess differences in the estimation and strength of the effect measures when partial protocols are adopted compared to full-mouth examination. Gingival bleeding at probing among adolescents (n = 339) and young adults (n = 720) and dental calculus and periodontal probing depth among young adults were assessed using full-mouth examinations and four partial protocols: Ramfjord teeth (RT), community periodontal index (CPI), and two random diagonal quadrants (1 and 3, 2 and 4). Socioeconomic, demographic, and periodontal health-related variables were also collected. Sensitivity, absolute and relative bias, and inflation factors were calculated. Prevalence ratio for each periodontal outcome for the risk factors was estimated. Two diagonal quadrants showed better accuracy; RT had the worst, whereas CPI presented an intermediate pattern when compared to full-mouth examination. For bleeding assessment in adolescence, RT and CPI underestimated by 18.4% and 16.2%, respectively, the true outcome prevalence, whereas among young adults, all partial protocols underestimated the prevalence. All partial protocols presented similar magnitude of association measures for all investigated periodontal potential risk factors. Two diagonal quadrants protocol may be effective in identifying the risk factors for the most relevant periodontal outcomes in adolescence and in young adulthood.

  7. Multitask protocols to evaluate activities of daily living performance in people with COPD: a systematic review.

    PubMed

    Paes, Thaís; Machado, Felipe Vilaça Cavallari; Cavalheri, Vinícius; Pitta, Fabio; Hernandes, Nidia Aparecida

    2017-07-01

    People with chronic obstructive pulmonary disease (COPD) present symptoms such as dyspnea and fatigue, which hinder their performance in activities of daily living (ADL). A few multitask protocols have been developed to assess ADL performance in this population, although measurement properties of such protocols were not yet systematically reviewed. Areas covered: Studies were included if an assessment of the ability to perform ADL was conducted in people with COPD using a (objective) performance-based protocol. The search was conducted in the following databases: Pubmed, EMBASE, Cochrane Library, PEDro, CINAHL and LILACS. Furthermore, hand searches were conducted. Expert commentary: Up to this moment, only three protocols had measurement properties described: the Glittre ADL Test, the Monitored Functional Task Evaluation and the Londrina ADL Protocol were shown to be valid and reliable whereas only the Glittre ADL Test was shown to be responsive to change after pulmonary rehabilitation. These protocols can be used in laboratory settings and clinical practice to evaluate ADL performance in people with COPD, although there is need for more in-depth information on their validity, reliability and especially responsiveness due to the growing interest in the accurate assessment of ADL performance in this population.

  8. Standards for Environmental Measurement Using GIS: Toward a Protocol for Protocols.

    PubMed

    Forsyth, Ann; Schmitz, Kathryn H; Oakes, Michael; Zimmerman, Jason; Koepp, Joel

    2006-02-01

    Interdisciplinary research regarding how the built environment influences physical activity has recently increased. Many research projects conducted jointly by public health and environmental design professionals are using geographic information systems (GIS) to objectively measure the built environment. Numerous methodological issues remain, however, and environmental measurements have not been well documented with accepted, common definitions of valid, reliable variables. This paper proposes how to create and document standardized definitions for measures of environmental variables using GIS with the ultimate goal of developing reliable, valid measures. Inherent problems with software and data that hamper environmental measurement can be offset by protocols combining clear conceptual bases with detailed measurement instructions. Examples demonstrate how protocols can more clearly translate concepts into specific measurement. This paper provides a model for developing protocols to allow high quality comparative research on relationships between the environment and physical activity and other outcomes of public health interest.

  9. Return of Postural Control to Baseline After Anaerobic and Aerobic Exercise Protocols

    PubMed Central

    Fox, Zachary G; Mihalik, Jason P; Blackburn, J Troy; Battaglini, Claudio L; Guskiewicz, Kevin M

    2008-01-01

    Context: With regard to sideline concussion testing, the effect of fatigue associated with different types of exercise on postural control is unknown. Objective: To evaluate the effects of fatigue on postural control in healthy college-aged athletes performing anaerobic and aerobic exercise protocols and to establish an immediate recovery time course from each exercise protocol for postural control measures to return to baseline status. Design: Counterbalanced, repeated measures. Setting: Research laboratory. Patients Or Other Participants: Thirty-six collegiate athletes (18 males, 18 females; age  =  19.00 ± 1.01 years, height  =  172.44 ± 10.47 cm, mass  =  69.72 ± 12.84 kg). Intervention(s): Participants completed 2 counterbalanced sessions within 7 days. Each session consisted of 1 exercise protocol followed by postexercise measures of postural control taken at 3-, 8-, 13-, and 18-minute time intervals. Baseline measures were established during the first session, before the specified exertion protocol was performed. Main Outcome Measure(s): Balance Error Scoring System (BESS) results, sway velocity, and elliptical sway area. Results: We found a decrease in postural control after each exercise protocol for all dependent measures. An interaction was noted between exercise protocol and time for total BESS score (P  =  .002). For both exercise protocols, all measures of postural control returned to baseline within 13 minutes. Conclusions: Postural control was negatively affected after anaerobic and aerobic exercise protocols as measured by total BESS score, elliptical sway area, and sway velocity. The effect of exertion lasted up to 13 minutes after each exercise was completed. Certified athletic trainers and clinicians should be aware of these effects and their recovery time course when determining an appropriate time to administer sideline assessments of postural control after a suspected mild traumatic brain injury. PMID:18833307

  10. Validation of the OMRON M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension.

    PubMed

    El Feghali, Ramzi N; Topouchian, Jirar A; Pannier, Bruno M; El Assaad, Hiba A; Asmar, Roland G

    2007-06-01

    A high percentage of hypertensive patients present an arm circumference of over 32 cm; the use of a large cuff is therefore recommended. Validation studies are usually performed in the general population using a standard-size cuff. The aim of this study was to assess the accuracy of the Omron M7 device in a population with an arm circumference ranging from 32 to 42 cm. A validation study was performed according to the International Protocol of the European Society of Hypertension. This protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood-pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood-pressure measurements), making a total number of 33 participants (99 pairs of blood-pressure measurements), on whom the analysis is performed. For each participant, four blood-pressure measurements were performed simultaneously by two trained observers, using mercury sphygmomanometers fitted with a Y tube; the measurements alternated with three by the test device. The difference between the blood-pressure value given by the device and that obtained by the two observers (mean of the two observations) was calculated for each measure. The 99 pairs of blood-pressure differences were classified into three categories (

  11. “Counterfactual” quantum protocols

    NASA Astrophysics Data System (ADS)

    Vaidman, L.

    2016-05-01

    The counterfactuality of recently proposed protocols is analyzed. A definition of “counterfactuality” is offered and it is argued that an interaction-free measurement (IFM) of the presence of an opaque object can be named “counterfactual”, while proposed “counterfactual” measurements of the absence of such objects are not counterfactual. The quantum key distribution protocols which rely only on measurements of the presence of the object are counterfactual, but quantum direct communication protocols are not. Therefore, the name “counterfactual” is not appropriate for recent “counterfactual” protocols which transfer quantum states by quantum direct communication.

  12. Sampling and measurement protocols for long-term silvicultural studies on the Penobscot Experimental Forest

    Treesearch

    Justin D. Waskiewicz; Laura S. Kenefic; Nicole S. Rogers; Joshua J. Puhlick; John C. Brissette; Richard J. Dionne

    2015-01-01

    The U.S. Forest Service, Northern Research Station has been conducting research on the silviculture of northern conifers on the Penobscot Experimental Forest (PEF) in Maine since 1950. Formal study plans provide guidance and specifications for the experimental treatments, but documentation is also needed to ensure consistency in data collection and sampling protocols....

  13. Comparison of the ultrashort gonadotropin-releasing hormone agonist-antagonist protocol with microdose flare -up protocol in poor responders: a preliminary study.

    PubMed

    Berker, Bülent; Duvan, Candan İltemir; Kaya, Cemil; Aytaç, Ruşen; Satıroğlu, Hakan

    2010-01-01

    To determine the potential effect of the ultrashort gonadotropin-releasing hormone (GnRH) agonist/GnRH antagonist protocol versus the microdose GnRH agonist protocol in poor responders undergoing intracytoplasmic sperm injection (ICSI). The patients in the Agonist-Antagonist Group (n=41) were administered the ultrashort GnRH-agonist/ antagonist protocol, while the patients in the Microdose Group (n=41) were stimulated according to the microdose flare-up protocol. The mean number of mature oocytes retrieved was the primary outcome measure. Fertilization rate, implantation rate per embryo and clinical pregnancy rates were secondary outcome measures. There was no differenc between the mean number of mature oocytes retrieved in the two groups. There were also no statistical differences between the two groups in terms of peak serum E2 level, canceled cycles, endometrial thickness on hCG day, number of 2 pronucleus and number of embryos transferred. However, the total gonadotropin consumption and duration of stimulation were significantly higher with the Agonist-Antagonist Group compared with the Microdose Group. The implantation and clinical pregnancy rates were similar between the two groups. Despite the high dose of gonadotropin consumption and longer duration of stimulation with the ultrashort GnRH agonist/ antagonist protocol, it seems that the Agonist-Antagonist Protocol is not inferior to the microdose protocol in poor responders undergoing ICSI.

  14. Dose uniformity analysis among ten 16-slice same-model CT scanners.

    PubMed

    Erdi, Yusuf Emre

    2012-01-01

    With the introduction of multislice scanners, computed tomographic (CT) dose optimization has become important. The patient-absorbed dose may differ among the scanners although they are the same type and model. To investigate the dose output variation of the CT scanners, we designed the study to analyze dose outputs of 10 same-model CT scanners using 3 clinical protocols. Ten GE Lightspeed (GE Healthcare, Waukesha, Wis) 16-slice scanners located at main campus and various satellite locations of our institution have been included in this study. All dose measurements were performed using poly (methyl methacrylate) (PMMA) head (diameter, 16 cm) and body (diameter, 32 cm) phantoms manufactured by Radcal (RadCal Corp, Monrovia, Calif) using a 9095 multipurpose analyzer with 10 × 9-3CT ion chamber both from the same manufacturer. Ion chamber is inserted into the peripheral and central axis locations and volume CT dose index (CTDIvol) is calculated as weighted average of doses at those locations. Three clinical protocol settings for adult head, high-resolution chest, and adult abdomen are used for dose measurements. We have observed up to 9.4% CTDIvol variation for the adult head protocol in which the largest variation occurred among the protocols. However, head protocol uses higher milliampere second values than the other 2 protocols. Most of the measured values were less than the system-stored CTDIvol values. It is important to note that reduction in dose output from tubes as they age is expected in addition to the intrinsic radiation output fluctuations of the same scanner. Although the same model CT scanners were used in this study, it is possible to see CTDIvol variation in standard patient scanning protocols of head, chest, and abdomen. The compound effect of the dose variation may be larger with higher milliampere and multiphase and multilocation CT scans.

  15. New approach to enhance and evaluate the performance of vehicle-infrastructure integration and its communication systems, final report.

    DOT National Transportation Integrated Search

    2010-09-01

    Initial research studied the use of wireless local area networks (WLAN) protocols in Inter-Vehicle Communications : (IVC) environments. The protocols performance was evaluated in terms of measuring throughput, jitter time and : delay time. This re...

  16. Comparison of protocols for measuring and calculating postmortem submersion intervals for human analogs in fresh water.

    PubMed

    Humphreys, Michael K; Panacek, Edward; Green, William; Albers, Elizabeth

    2013-03-01

    Protocols for determining postmortem submersion interval (PMSI) have long been problematic for forensic investigators due to the wide variety of factors affecting the rate of decomposition of submerged carrion. Likewise, it has been equally problematic for researchers to develop standardized experimental protocols to monitor underwater decomposition without artificially affecting the decomposition rate. This study compares two experimental protocols: (i) underwater in situ evaluation with photographic documentation utilizing the Heaton et al. total aquatic decomposition (TAD) score and (ii) weighing the carrion before and after submersion. Complete forensic necropsies were performed as a control. Perinatal piglets were used as human analogs. The results of this study indicate that in order to objectively measure decomposition over time, the human analog should be examined at depth using the TAD scoring system rather than utilizing a carrion weight evaluation. The acquired TAD score can be used to calculate an approximate PMSI. © 2012 American Academy of Forensic Sciences.

  17. Evaluation of Vitamin D Standardization Program protocols for standardizing serum 25-hydroxyvitamin D data: a case study of the program's potential for national nutrition and health surveys12345

    PubMed Central

    Cashman, Kevin D; Kiely, Mairead; Kinsella, Michael; Durazo-Arvizu, Ramón A; Tian, Lu; Zhang, Yue; Lucey, Alice; Flynn, Albert; Gibney, Michael J; Vesper, Hubert W; Phinney, Karen W; Coates, Paul M; Picciano, Mary F; Sempos, Christopher T

    2013-01-01

    Background: The Vitamin D Standardization Program (VDSP) has developed protocols for standardizing procedures of 25-hydroxyvitamin D [25(OH)D] measurement in National Health/Nutrition Surveys to promote 25(OH)D measurements that are accurate and comparable over time, location, and laboratory procedure to improve public health practice. Objective: We applied VDSP protocols to existing ELISA-derived serum 25(OH)D data from the Irish National Adult Nutrition Survey (NANS) as a case-study survey and evaluated their effectiveness by comparison of the protocol-projected estimates with those from a reanalysis of survey serums by using liquid chromatography–tandem mass spectrometry (LC–tandem MS). Design: The VDSP reference system and protocols were applied to ELISA-based serum 25(OH)D data from the representative NANS sample (n = 1118). A reanalysis of 99 stored serums by using standardized LC–tandem MS and resulting regression equations yielded predicted standardized serum 25(OH)D values, which were then compared with LC–tandem MS reanalyzed values for all serums. Results: Year-round prevalence rates for serum 25(OH)D concentrations <30, <40, and <50 nmol/L were 6.5%, 21.9%, and 40.0%, respectively, via original ELISA measurements and 11.4%, 25.3%, and 43.7%, respectively, when VDSP protocols were applied. Differences in estimates at <30- and <40-nmol/L thresholds, but not at the <50-nmol/L threshold, were significant (P < 0.05). A reanalysis of all serums by using LC–tandem MS confirmed prevalence estimates as 11.2%, 27.2%, and 45.0%, respectively. Prevalences of serum 25(OH)D concentrations >125 nmol/L were 1.2%, 0.3%, and 0.6% by means of ELISA, VDSP protocols, and LC–tandem MS, respectively. Conclusion: VDSP protocols hold a major potential for national nutrition and health surveys in terms of the standardization of serum 25(OH)D data. PMID:23615829

  18. Guidelines for experimental design protocol and validation procedure for the measurement of heat resistance of microorganisms in milk.

    PubMed

    Condron, Robin; Farrokh, Choreh; Jordan, Kieran; McClure, Peter; Ross, Tom; Cerf, Olivier

    2015-01-02

    Studies on the heat resistance of dairy pathogens are a vital part of assessing the safety of dairy products. However, harmonized methodology for the study of heat resistance of food pathogens is lacking, even though there is a need for such harmonized experimental design protocols and for harmonized validation procedures for heat treatment studies. Such an approach is of particular importance to allow international agreement on appropriate risk management of emerging potential hazards for human and animal health. This paper is working toward establishment of a harmonized protocol for the study of the heat resistance of pathogens, identifying critical issues for establishment of internationally agreed protocols, including a harmonized framework for reporting and interpretation of heat inactivation studies of potentially pathogenic microorganisms. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Regional citrate anticoagulation in hemodialysis: an observational study of safety, efficacy, and effect on calcium balance during routine care.

    PubMed

    Singer, Richard F; Williams, Oliver; Mercado, Chari; Chen, Bonny; Talaulikar, Girish; Walters, Giles; Roberts, Darren M

    2016-01-01

    Regional citrate hemodialysis anticoagulation is used when heparin is contraindicated, but most protocols require large infusions of calcium and frequent intradialytic plasma ionized calcium measurements. The objective of this study was to determine the safety, efficacy, and effect on calcium balance of regional citrate anticoagulation using sparse plasma ionized calcium sampling. The design of this study was observational. The setting of this study was the hospital hemodialysis center. The subjects of this study were the hospital hemodialysis patients. Dialysate calcium concentration by atomic absorption spectroscopy and total dialysate weight were used as measurements. Regional citrate anticoagulation was introduced using zero calcium dialysate, pre-dialyzer citrate infusion, and post-dialyzer calcium infusion. Infusions were adjusted based on pre- and post-dialyzer calcium measurements obtained at least twice during a 4-h dialysis. The protocol was simplified after the first 357 sessions to dispense with post-dialyzer calcium measurements. Heparin-anticoagulated sessions were performed using acetate-acidified 1.25 mmol/L calcium or citrate-acidified 1.5 mmol/L calcium dialysate. Calcium balance assessment was by complete dialysate recovery. Safety and efficacy were assessed prospectively using a point-of-care database to record ionized calcium and clinical events. Groups were compared using t test, ANOVA, Wilcoxon rank sum, or Kruskal-Wallis as appropriate. Seventy-five patients received regional citrate-anticoagulated dialysis over 1051 dialysis sessions. Of these, 357 dialysis sessions were performed using the original citrate anticoagulation protocol and 694 using the simplified protocol. Dialysis was effective and safe. Only 3 dialyzers clotted; 1 patient suffered symptomatic hypercalcemia and none suffered symptomatic hypocalcemia. Calcium balance was assessed in 15 regional citrate-anticoagulated dialysis sessions and 30 heparin-anticoagulated sessions. The median calcium loss was 0.8 mmol/h dialyzed in both groups (p = 0.43), and end of treatment ionized calcium was the same in both groups (1.07 ± 0.04 mmol/L). Our findings for calcium balance, efficacy, and safety are valid only for the protocol studied, which excluded patient with severe liver dysfunction. Regional citrate dialysis can be performed safely and effectively using a sparse plasma calcium sampling protocol. The calcium balance induced by this protocol is not different to that seen in standard heparin-anticoagulated dialysis, but in the absence of prospective studies, it is unknown whether this is optimal for patient care.

  20. Very low intravenous contrast volume protocol for computed tomography angiography providing comprehensive cardiac and vascular assessment prior to transcatheter aortic valve replacement in patients with chronic kidney disease.

    PubMed

    Pulerwitz, Todd C; Khalique, Omar K; Nazif, Tamim N; Rozenshtein, Anna; Pearson, Gregory D N; Hahn, Rebecca T; Vahl, Torsten P; Kodali, Susheel K; George, Isaac; Leon, Martin B; D'Souza, Belinda; Po, Ming Jack; Einstein, Andrew J

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable. 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30 mL/min) who underwent a novel VLCV protocol (20 mL of iohexol at 2.5 mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale. VLCV patients had mean (±SD) age 86 ± 6.5, BMI 23.9 ± 3.4 kg/m(2) with 54% men; SCV patients age 83 ± 8.8, BMI 28.7 ± 5.3 kg/m(2), 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement. This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  1. Effects of the Voice over Internet Protocol on Perturbation Analysis of Normal and Pathological Phonation

    PubMed Central

    Zhu, Yanmei; Witt, Rachel E.; MacCallum, Julia K.; Jiang, Jack J.

    2010-01-01

    Objective In this study, a Voice over Internet Protocol (VoIP) communication based on G.729 protocol was simulated to determine the effects of this system on acoustic perturbation parameters of normal and pathological voice signals. Patients and Methods: Fifty recordings of normal voice and 48 recordings of pathological voice affected by laryngeal paralysis were transmitted through a VoIP communication system. The acoustic analysis programs of CSpeech and MDVP were used to determine the percent jitter and percent shimmer from the voice samples before and after VoIP transmission. The effects of three frequently used audio compression protocols (MP3, WMA, and FLAC) on the perturbation measures were also studied. Results It was found that VoIP transmission disrupts the waveform and increases the percent jitter and percent shimmer of voice samples. However, after VoIP transmission, significant discrimination between normal and pathological voices affected by laryngeal paralysis was still possible. It was found that the lossless compression method FLAC does not exert any influence on the perturbation measures. The lossy compression methods MP3 and WMA increase percent jitter and percent shimmer values. Conclusion This study validates the feasibility of these transmission and compression protocols in developing remote voice signal data collection and assessment systems. PMID:20588051

  2. Reliability of a Novel High Intensity One Leg Dynamic Exercise Protocol to Measure Muscle Endurance

    PubMed Central

    Lepers, Romuald; Marcora, Samuele M.

    2016-01-01

    We recently developed a high intensity one leg dynamic exercise (OLDE) protocol to measure muscle endurance and investigate the central and peripheral mechanisms of muscle fatigue. The aims of the present study were to establish the reliability of this novel protocol and describe the isokinetic muscle fatigue induced by high intensity OLDE and its recovery. Eight subjects performed the OLDE protocol (time to exhaustion test of the right leg at 85% of peak power output) three times over a week period. Isokinetic maximal voluntary contraction torque at 60 (MVC60), 100 (MVC100) and 140 (MVC140) deg/s was measured pre-exercise, shortly after exhaustion (13 ± 4 s), 20 s (P20) and 40 s (P40) post-exercise. Electromyographic (EMG) signal was analyzed via the root mean square (RMS) for all three superficial knee extensors. Mean time to exhaustion was 5.96 ± 1.40 min, coefficient of variation was 8.42 ± 6.24%, typical error of measurement was 0.30 min and intraclass correlation was 0.795. MVC torque decreased shortly after exhaustion for all angular velocities (all P < 0.001). MVC60 and MVC100 recovered between P20 (P < 0.05) and exhaustion and then plateaued. MVC140 recovered only at P40 (P < 0.05). High intensity OLDE did not alter maximal EMG RMS of the three superficial knee extensors during MVC. The results of this study demonstrate that this novel high intensity OLDE protocol could be reliably used to measure muscle endurance, and that muscle fatigue induced by high intensity OLDE should be examined within ~ 30 s following exhaustion. PMID:27706196

  3. Validation of the Omron M3 Intellisense (HEM-7051-E) upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010 in a stage 3-5 chronic kidney disease population.

    PubMed

    Akpolat, Tekin; Erdem, Emre; Aydogdu, Türkan

    2012-01-01

    Encouragement of home blood pressure (BP) monitoring has a great potential to improve hypertension control rates. The purpose of this study was to test validation of the Omron M3 Intellisense (HEM-7051-E) upper arm BP measuring monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP2) in stage 3-5 chronic kidney disease (CKD) patients. 66 patients having CKD stage 3-5 were included in the study. Nine consecutive measurements were made according to the ESH-IP2 protocol. The Omron M3 Intellisense device fulfills the validation criteria of the ESH-IP2 for stage 3-5 CKD patients. Although arterial stiffness can affect accurate BP measurement, there are limited data regarding the use of automated oscillometric devices in CKD. To our knowledge, this is the first study investigating validation of an oscillometric device in stage 3-5 predialysis CKD patients. This study validates the Omron M3 Intellisense upper arm device for stage 3-5 CKD patients. New validation studies investigating other oscillometric sphygmomanometers for CKD patients and involvement of nephrologists in these studies have great potential to increase patient care in CKD. Copyright © 2011 S. Karger AG, Basel.

  4. OVERALL PROCEDURES PROTOCOL AND PATIENT ENROLLMENT PROTOCOL: TESTING FEASIBILITY OF 3D ULTRASOUND DATA ACQUISITION AND RELIABILITY OF DATA RETRIEVAL FROM STORED 3D IMAGES

    EPA Science Inventory

    The purpose of this study is to examine the feasibility of collecting, transmitting,

    and analyzing 3-D ultrasound data in the context of a multi-center study of pregnant

    women. The study will also examine the reliability of measurements obtained from 3-D

    imag...

  5. Dynamic Postural Control in Female Athletes and Nonathletes After a Whole-Body Fatigue Protocol.

    PubMed

    Baghbani, Fatemeh; Woodhouse, Linda J; Gaeini, Abbas A

    2016-07-01

    Baghbani, F, Woodhouse, LJ, and Gaeini, AA. Dynamic postural control in female athletes and nonathletes after a whole-body fatigue protocol. J Strength Cond Res 30(7): 1942-1947, 2016-Postural control is a crucial element in regular training of athletes, development of complex technical movement, and injury prevention; however, distributing factor of the postural control such as fatigue has been neglected by athletic trainers in novice and inexperienced athletes. The objective of this study was to compare changes in dynamic postural control of young female athletes and nonathletes after a fatigue protocol. Thirty females (15 athletes and 15 nonathletes) with no orthopedic problems were recruited to participate in this study. All participants completed the pre-SEBT (star excursion balance test) in 8 directions at baseline; then, they performed a 20-minute fatigue protocol after which post-SEBT was measured. Rating of perceived exertion was measured using the Borg scale immediately before, mid-way through (i.e., after the third station), and after performing the fatigue protocol (i.e., immediately before the post-SEBT). Female nonathlete groups had significant differences in dynamic balance performance after fatigue in the medial, posteromedial, and posterior directions (p < 0.01) measured by SEBT. Athletes, however, showed no significant changes after the fatigue protocol. Our results indicates the importance of evaluation and monitoring of dynamic postural control of the novice with progressing the exercise time. Our findings could also help coaches to develop trainings focused on the 3 directions of medial, posteromedial, and posterior directions and aimed at exercises increasing fatigue resistance.

  6. Performance assessment of a glucose control protocol in septic patients with an automated intermittent plasma glucose monitoring device.

    PubMed

    Umbrello, M; Salice, V; Spanu, P; Formenti, P; Barassi, A; Melzi d'Eril, G V; Iapichino, G

    2014-10-01

    The optimal level and modality of glucose control in critically ill patients is still debated. A protocolized approach and the use of nearly-continuous technologies are recommended to manage hyperglycemia, hypoglycemia and glycemic variability. We recently proposed a pato-physiology-based glucose control protocol which takes into account patient glucose/carbohydrate intake and insulin resistance. Aim of the present investigation was to assess the performance of our protocol with an automated intermittent plasma glucose monitoring device (OptiScanner™ 5000). OptiScanner™ was used in 6 septic patients, providing glucose measurement every 15' from a side-port of an indwelling central venous catheter. Target level of glucose was 80-150 mg/dL. Insulin infusion and kcal with nutritional support were also recorded. 6 septic patients were studied for 319 h (1277 measurements); 58 [45-65] hours for each patient (measurements/patient: 231 [172-265]). Blood glucose was at target for 93 [90-98]% of study time. Mean plasma glucose was 126 ± 11 mg/dL. Only 3 hypoglycemic episodes (78, 78, 69 mg/dL) were recorded. Glucose variability was limited: plasma glucose coefficient of variation was 11.7 ± 4.0% and plasma glucose standard deviation was 14.3 ± 5.5 mg/dL. The local glucose control protocol achieved satisfactory glucose control in septic patients along with a high degree of safeness. Automated intermittent plasma glucose monitoring seemed useful to assess the performance of the protocol. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  7. What is the optimal way to prepare a Bell state using measurement and feedback?

    NASA Astrophysics Data System (ADS)

    Martin, Leigh; Sayrafi, Mahrud; Whaley, K. Birgitta

    2017-12-01

    Recent work has shown that the use of quantum feedback can significantly enhance both the speed and success rate of measurement-based remote entanglement generation, but it is generally unknown what feedback protocols are optimal for these tasks. Here we consider two common measurements that are capable of projecting into pairwise entangled states, namely half- and full-parity measurements of two qubits, and determine in each case a globally optimal protocol for generation of entanglement. For the half-parity measurement, we rederive a previously described protocol using more general methods and prove that it is globally optimal for several figures of merit, including maximal concurrence or fidelity and minimal time to reach a specified concurrence or fidelity. For the full-parity measurement, we derive a protocol for rapid entanglement generation related to that of (Hill, Ralph, Phys. Rev. A 77, 014305), and then map the dynamics of the concurrence of the state to the Bloch vector length of an effective qubit. This mapping allows us to prove several optimality results for feedback protocols with full-parity measurements. We further show that our full-parity protocol transfers entanglement optimally from one qubit to the other amongst all measurement-based schemes. The methods developed here will be useful for deriving feedback protocols and determining their optimality properties in many other quantum systems subject to measurement and unitary operations.

  8. CINRG: Infrastructure for Clinical Trials in Duchenne Dystrophy

    DTIC Science & Technology

    2012-09-01

    Cardiac Outcome Measures in Children with Muscular Dystrophy o Cardiac MRI Protocol: PITT0110 - Cardiac Magnetic Resonance: A Parallel Protocol...permitted during the study. Study drug. The study drug was PTX (Trental; Sanofi- Aventis U.S. LLC, Bridgewater, NJ) tablets , an FDA-approved pharmaceutical...that is available for oral administration as 400-mg oblong tablets . Both the study drug PTX and placebo were overencapsulated by Capsugel (Pfizer Inc

  9. An Efficient and Secure Arbitrary N-Party Quantum Key Agreement Protocol Using Bell States

    NASA Astrophysics Data System (ADS)

    Liu, Wen-Jie; Xu, Yong; Yang, Ching-Nung; Gao, Pei-Pei; Yu, Wen-Bin

    2018-01-01

    Two quantum key agreement protocols using Bell states and Bell measurement were recently proposed by Shukla et al. (Quantum Inf. Process. 13(11), 2391-2405, 2014). However, Zhu et al. pointed out that there are some security flaws and proposed an improved version (Quantum Inf. Process. 14(11), 4245-4254, 2015). In this study, we will show Zhu et al.'s improvement still exists some security problems, and its efficiency is not high enough. For solving these problems, we utilize four Pauli operations { I, Z, X, Y} to encode two bits instead of the original two operations { I, X} to encode one bit, and then propose an efficient and secure arbitrary N-party quantum key agreement protocol. In the protocol, the channel checking with decoy single photons is introduced to avoid the eavesdropper's flip attack, and a post-measurement mechanism is used to prevent against the collusion attack. The security analysis shows the present protocol can guarantee the correctness, security, privacy and fairness of quantum key agreement.

  10. Validation protocols for blood pressure-measuring devices: status quo and development needs.

    PubMed

    Beime, Beate; Deutsch, Cornelia; Gomez, Timothy; Zwingers, Thomas; Mengden, Thomas; Bramlage, Peter

    2016-02-01

    Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy of blood pressure monitoring devices have been developed, including protocols by the Association for the Advancement of Medical Instrumentation, the British Hypertension Society, the German Hypertension League (Prüfsiegelprotokoll), and the International Protocol of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. In the past, most of the protocols have been reviewed and modified because of experiences gained during the validation studies carried out. However, each shows distinct differences, that is number and characteristics of patients required, blood pressure ranges, and the length of the validation procedure, which may result in unique advantages and/or limitations associated with their use. The continued standardization and evolution of these guidelines is essential to ensure the efficacy of blood pressure-measuring devices marketed for clinical and home use. Here, we aimed to compare four currently used validation protocols and to initiate a discussion on potential future improvements.

  11. First in vivo assessment of "Outwalk": a novel protocol for clinical gait analysis based on inertial and magnetic sensors.

    PubMed

    Ferrari, Alberto; Cutti, Andrea Giovanni; Garofalo, Pietro; Raggi, Michele; Heijboer, Monique; Cappello, Angelo; Davalli, Angelo

    2010-01-01

    A protocol named "Outwalk" was recently proposed to measure the thorax-pelvis and lower-limb kinematics during gait in free-living conditions, by means of an inertial and magnetic measurement system (IMMS). The aim of this study was to validate Outwalk on four healthy subjects when it is used in combination with a specific IMMS (Xsens Technologies, NL), against a reference protocol (CAST) and measurement system (optoelectronic system; Vicon, Oxford Metrics Group, UK). For this purpose, we developed an original approach based on three tests, which allowed to separately investigate: (1) the consequences on joint kinematics of the differences between protocols (Outwalk vs. CAST), (2) the accuracy of the hardware (Xsens vs. Vicon), and (3) the summation of protocols' differences and hardware accuracy (Outwalk + Xsens vs. CAST + Vicon). In order to assess joint-angles similarity, the coefficient of multiple correlation (CMC) was used. For test 3, the CMC showed that Outwalk + Xsens and CAST + Vicon kinematics can be interchanged, offset included, for hip, knee and ankle flexion-extension, and hip ab-adduction (CMC > 0.88). The other joint-angles can be interchanged offset excluded (CMC > 0.85). Tests 1 and 2 also showed that differences in offset between joint-angles were predominantly induced by differences in the protocols; differences in correlation by both hardware and protocols; differences in range of motion by the Xsens accuracy. Results thus support the commencement of a clinical trial of Outwalk on transtibial amputees.

  12. Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension.

    PubMed

    Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Ibanez, Isabel; Khabouth, Jose; Khawaja, Salwa; Beaino, Layale; Asmar, Roland

    2011-01-01

    Four oscillometric devices for self-measurement of blood pressure (SBPM) were evaluated according to the European Society of Hypertension (ESH) international protocol and its 2010 revision in four separate studies. The Omron® M2, Omron M3, and Omron M6 measure blood pressure (BP) at the brachial level, while the Omron R2 measures BP at the wrist level. The international protocol requires a total number of 33 subjects in which the validation is performed. The Omron M2 and Omron R2 were validated in 2009 according to the ESH international protocol, while the Omron M3 and Omron M6 were validated in 2010-2011 according to the 2010 ESH international protocol revision. The protocol procedures were followed precisely. All four tested devices passed the validation process. The mean differences between the device and mercury readings were 2.7 ± 5.0 and -1.4 ± 3.2 mmHg for systolic and diastolic BP, respectively, using the Omron M2 device, and 1.7 ± 3.2 and -0.9 ± 2.6 mmHg using the Omron M3, 1.6 ± 2.9 and -0.9 ± 2.5 mmHg using the Omron M6, and -1.1 ± 4.8 and -0.9 ± 4.3 mmHg using the Omron R2. Readings from the Omron M2, Omron M3, Omron M6, and Omron R2, differing by less than 5, 10, and 15 mmHg, fulfill the ESH international protocol and its 2010 revision requirements. Therefore, each of these four devices can be used by patients for SBPM.

  13. Development of a systematic observation protocol of physical exposure of the back: a preliminary study.

    PubMed

    Tousignant, M; Tougas, G; Rossignol, M; Goulet, L

    2002-04-01

    At present there is no systematic observation protocol for the assessment of the multi-factorial aspects of physical exposure related to the back used within the constraints of occupational epidemiological research. In this context, a new preliminary systematic observation protocol is proposed to assess exposure to physical loading of the back using nine categories of physical risk factors: the SOPE back protocol. The objective of this study was to investigate whether the new protocol can correctly identify the level of exposure related to measured physical loading of the back. The subjects of this closed cohort study were 451 manual workers at a natural gas distribution company. The assessment of exposure was made with the protocol using groups with different job titles. The workers were followed for a 2 yr period to establish the risk of a new occurrence of complete disability related to the back (NOCD back injury) in each job grouping. Based on the median of the total scores derived from the protocol, two levels of exposure were identified (high and low). Taking into account the limitations of this study, the protocol in development may be a good tool to establish two levels of exposure to physical loading of the back in large epidemiological studies of occupational low back pain. Further research is needed to replicate these results with larger samples and to test the reliability and predictive validity of the protocol.

  14. Assessment tools for the measurement of the self-efficacy of drug users: protocol for a systematic review

    PubMed Central

    Vasconcelos, Selene Cordeiro; Frazão, Iracema da Silva; Sougey, Everton Botelho; de Souza, Sandra Lopes; da Silva, Tatiana de Paula Santana; Lima, Murilo Duarte da Costa

    2018-01-01

    Introduction The abuse of alcohol and other drugs is a worldwide problem, the treatment of which poses a challenge to healthcare workers. Objective This study presents a proposal for a systematic review to analyse the psychometric properties of assessment tools developed to measure the self-efficacy of drug users with regard to resisting the urge to take drugs in high-risk situations. Methods and Analysis The guiding question was based on PICOS (Population Intervention Comparator Outcome Setting), and the report of the methods of review protocol was written in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols (PRISMA-P). Searches will be performed in the PsycINFO, Cochrane, Pubmed, Web of Science, SCOPUS and CINAHL databases, followed by the use of the ‘snowball’ strategy. The inclusion criteria for the articles will be (1) assessment tool validation studies; (2) assessment tools developed to measure self-efficacy; (3) quantitative measures; (4) measures designed for use on adults; (5) data from self-reports of the participants; (6) studies involving a description of psychometric properties of the measures; and (7) studies that explain how the level of self-efficacy is scored. The search, selection and analysis will be performed by two independent reviewers. In cases of a divergence of opinion, a third reviewer will be consulted. The COSMIN checklist will be used for the appraisal of the methodological quality of the assessment tools and the certainty of the evidence in the articles (risk of bias) will be analysed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. Ethics and dissemination This protocol does not require ethical approval. However, this protocol is part of the thesis entitled Drug-Taking Confidence Questionnaire for use in Brazil, presented for obtaining a doctorate in neuropsychiatry and behavioural sciences from the Federal University of Pernambuco, and has received approval from the human research ethics committee of the Federal University of Pernambuco (reference number: 1.179.162). The results will be disseminated to clinicians and researchers through peer-reviewed publications and conferences. PROSPERO registration number CRD42017068555. PMID:29540409

  15. Verification of a Proposed Clinical Electroacoustic Test Protocol for Personal Digital Modulation Receivers Coupled to Cochlear Implant Sound Processors.

    PubMed

    Nair, Erika L; Sousa, Rhonda; Wannagot, Shannon

    Guidelines established by the AAA currently recommend behavioral testing when fitting frequency modulated (FM) systems to individuals with cochlear implants (CIs). A protocol for completing electroacoustic measures has not yet been validated for personal FM systems or digital modulation (DM) systems coupled to CI sound processors. In response, some professionals have used or altered the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting FM systems to CI sound processors. More recently steps were outlined in a proposed protocol. The purpose of this research is to review and compare the electroacoustic test measures outlined in a 2013 article by Schafer and colleagues in the Journal of the American Academy of Audiology titled "A Proposed Electroacoustic Test Protocol for Personal FM Receivers Coupled to Cochlear Implant Sound Processors" to the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting DM systems to CI users. Electroacoustic measures were conducted on 71 CI sound processors and Phonak Roger DM systems using a proposed protocol and an adapted AAA protocol. Phonak's recommended default receiver gain setting was used for each CI sound processor manufacturer and adjusted if necessary to achieve transparency. Electroacoustic measures were conducted on Cochlear and Advanced Bionics (AB) sound processors. In this study, 28 Cochlear Nucleus 5/CP810 sound processors, 26 Cochlear Nucleus 6/CP910 sound processors, and 17 AB Naida CI Q70 sound processors were coupled in various combinations to Phonak Roger DM dedicated receivers (25 Phonak Roger 14 receivers-Cochlear dedicated receiver-and 9 Phonak Roger 17 receivers-AB dedicated receiver) and 20 Phonak Roger Inspiro transmitters. Employing both the AAA and the Schafer et al protocols, electroacoustic measurements were conducted with the Audioscan Verifit in a clinical setting on 71 CI sound processors and Phonak Roger DM systems to determine transparency and verify FM advantage, comparing speech inputs (65 dB SPL) in an effort to achieve equal outputs. If transparency was not achieved at Phonak's recommended default receiver gain, adjustments were made to the receiver gain. The integrity of the signal was monitored with the appropriate manufacturer's monitor earphones. Using the AAA hearing aid protocol, 50 of the 71 CI sound processors achieved transparency, and 59 of the 71 CI sound processors achieved transparency when using the proposed protocol at Phonak's recommended default receiver gain. After the receiver gain was adjusted, 3 of 21 CI sound processors still did not meet transparency using the AAA protocol, and 2 of 12 CI sound processors still did not meet transparency using the Schafer et al proposed protocol. Both protocols were shown to be effective in taking reliable electroacoustic measurements and demonstrate transparency. Both protocols are felt to be clinically feasible and to address the needs of populations that are unable to reliably report regarding the integrity of their personal DM systems. American Academy of Audiology

  16. Measurement of Lipid Accumulation in Chlorella vulgaris via Flow Cytometry and Liquid-State ¹H NMR Spectroscopy for Development of an NMR-Traceable Flow Cytometry Protocol

    PubMed Central

    Bono Jr., Michael S.; Garcia, Ravi D.; Sri-Jayantha, Dylan V.; Ahner, Beth A.; Kirby, Brian J.

    2015-01-01

    In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r 2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols. PMID:26267664

  17. SU-E-J-11: Measurement of Eye Lens Dose for Varian On-Board Imaging with Different CBCT Acquisition Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deshpande, S; Dhote, D; Kumar, R

    Purpose: To measure actual patient eye lens dose for different cone beam computed tomography (CBCT) acquisition protocol of Varian’s On Board Imagining (OBI) system using Optically Stimulated Luminescence (OSL) dosimeter and study the eye lens dose with patient geometry and distance of isocenter to the eye lens Methods: OSL dosimeter was used to measure eye lens dose of patient. OSL dosimeter was placed on patient forehead center during CBCT image acquisition to measure eye lens dose. For three different cone beam acquisition protocol (standard dose head, low dose head and high quality head) of Varian On-Board Imaging, eye lens dosesmore » were measured. Measured doses were correlated with patient geometry and distance between isocenter to eye lens. Results: Measured eye lens dose for standard dose head was in the range of 1.8 mGy to 3.2 mGy, for high quality head protocol dose was in range of 4.5mGy to 9.9 mGy whereas for low dose head was in the range of 0.3mGy to 0.7mGy. Dose to eye lens is depends upon position of isocenter. For posterioraly located tumor eye lens dose is less. Conclusion: From measured doses it can be concluded that by proper selection of imagining protocol and frequency of imaging, it is possible to restrict the eye lens dose below the new limit set by ICRP. However, undoubted advantages of imaging system should be counter balanced by careful consideration of imaging protocol especially for very intense imaging sequences for Adoptive Radiotherapy or IMRT.« less

  18. Measurement of lipid accumulation in Chlorella vulgaris via flow cytometry and liquid-state ¹H NMR spectroscopy for development of an NMR-traceable flow cytometry protocol.

    PubMed

    Bono, Michael S; Garcia, Ravi D; Sri-Jayantha, Dylan V; Ahner, Beth A; Kirby, Brian J

    2015-01-01

    In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols.

  19. The Cost-Effectiveness of an Intensive Treatment Protocol for Severe Dyslexia in Children

    ERIC Educational Resources Information Center

    Hakkaart-van Roijen, Leona; Goettsch, Wim G.; Ekkebus, Michel; Gerretsen, Patty; Stolk, Elly A.

    2011-01-01

    Studies of interventions for dyslexia have focused entirely on outcomes related to literacy. In this study, we considered a broader picture assessing improved quality of life compared with costs. A model served as a tool to compare costs and effects of treatment according to a new protocol and care as usual. Quality of life was measured and valued…

  20. Validation of the Omron M6 (HEM-7001-E) upper arm blood pressure measuring device according to the International Protocol in elderly patients.

    PubMed

    Altunkan, Sekip; Iliman, Nevzat; Altunkan, Erkan

    2008-04-01

    Despite the widespread use of automated self-measurement monitors, there is limited published evidence on their accuracy and reliability on different patient groups. The objective of this study was to evaluate the accuracy and reliability of the Omron M6 (HEM-7001-E) upper-arm blood pressure (BP) device against mercury sphygmomanometer on elderly patients according to the criteria of the International Protocol. Thirty-three patients above 65 years of age, who were classified based on the BP categories of the International Protocol, were recruited for the study. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. During the validation study, 99 measurements were obtained from 33 patients for comparison. The first phase was carried out on 15 patients and if the device passed this phase, 18 more patients were selected. Mean discrepancies and standard deviations of the device sphygmomanometer were 1.4+/-5.3 mmHg for systolic BP (SBP) and -1.4+/-4.5 mmHg for diastolic BP (DBP) in the study group. The device passed phase 1 in 15 patients. In phase 2.1, from the total 99 comparisons, 76, 92, and 97 for SBP and 77, 94, and 99 for DBP were less than 5, 10, and 15 mmHg, respectively. The Omron M6 passed phases 2.1 and 2.2 in the elderly group of patients. The Omron M6 (HEM-7001-E) upper-arm BP monitor passed according to the International Protocol criteria and can be recommended for use in elderly patients.

  1. Indirect calorimetry protocol development for measuring resting metabolic rate as a component of total energy expenditure in free-living postmenopausal women.

    PubMed

    Horner, N K; Lampe, J W; Patterson, R E; Neuhouser, M L; Beresford, S A; Prentice, R L

    2001-08-01

    An objective measure of energy intake is needed in epidemiologic studies to evaluate random and systematic error associated with dietary self-report tools. Total energy expenditure in weight-stable humans is accepted as a measure of energy intake, but doubly labeled water remains cost prohibitive for large studies. Our purpose was to develop a practical indirect calorimetry (IC) protocol for estimating resting metabolic rate (RMR) in free-living, postmenopausal women. We conducted duplicate IC measures 1 wk apart using a canopy system on 102 women ages 50-79 y from the Seattle area. We compared RMR for 0-5, 5-10, 5-15, 5-20, 5-25, 5-30, and 0- to 30-min IC segments and segments meeting stability criteria. The mean RMR for the first 5 min was significantly higher than other time segments (P = 0.001). Correlation coefficients between duplicate measures were high (r = 0.90). Use of defined stability criteria produced RMR measures that were 10-30 kcal (42-126 kJ) higher than the 5- to 10-min RMR measures and 40-60% of subjects did not achieve these stability criteria. For protocols including IC to assess RMR as a component of total energy expenditure in free-living, postmenopausal women, a single 10-min canopy study, excluding the first 5 min of data, produces reliable results with minimal subject burden.

  2. Effectiveness of a transdiagnostic internet-based protocol for the treatment of emotional disorders versus treatment as usual in specialized care: study protocol for a randomized controlled trial.

    PubMed

    González-Robles, Alberto; García-Palacios, Azucena; Baños, Rosa; Riera, Antonio; Llorca, Ginés; Traver, Francisco; Haro, Gonzalo; Palop, Vicente; Lera, Guillem; Romeu, José Enrique; Botella, Cristina

    2015-10-31

    Emotional disorders (depression and anxiety disorders) are highly prevalent mental health problems. Although evidence showing the effectiveness of disorder-specific treatments exists, high comorbidity rates among emotional disorders limit the utility of these protocols. This has led some researchers to focus their interest on transdiagnostic interventions, a treatment perspective that might be more widely effective across these disorders. Also, the current way of delivering treatments makes it difficult provide assistance to all of the population in need. The use of the Internet in the delivery of evidence-based treatments may help to disseminate treatments among the population. In this study, we aim to test the effectiveness of EmotionRegulation, a new transdiagnostic Internet-based protocol for unipolar mood disorders, five anxiety disorders (panic disorder, agoraphobia, social anxiety disorder, generalized anxiety disorder and anxiety disorder not otherwise specified), and obsessive-compulsive disorder in comparison to treatment as usual as provided in Spanish public specialized mental health care. We will also study its potential impact on basic temperament dimensions (neuroticism/behavioral inhibition and extraversion/behavioral activation). Expectations and opinions of patients about this protocol will also be studied. The study is a randomized controlled trial. 200 participants recruited in specialized care will be allocated to one of two treatment conditions: a) EmotionRegulation or b) treatment as usual. Primary outcome measures will be the BAI and the BDI-II. Secondary outcomes will include a specific measure of the principal disorder, and measures of neuroticism/behavioral inhibition and extraversion/behavioral activation. Patients will be assessed at baseline, post-treatment, and 3- and 12-month follow-ups. Intention to treat and per protocol analyses will be performed. Although the effectiveness of face-to-face transdiagnostic protocols has been investigated in previous studies, the number of published transdiagnostic Internet-based programs is still quite low. To our knowledge, this is the first randomized controlled trial studying the effectiveness of a transdiagnostic Internet-based treatment for several emotional disorders in public specialized care. Combining both a transdiagnostic approach with an Internet-based therapy format may help to decrease the burden of mental disorders, reducing the difficulties associated with disorder-specific treatments and facilitating access to people in need of treatment. Strengths and limitations are discussed. ClinicalTrials.gov NCT02345668 . Registered 27 July 2015.

  3. Analysis of the contribution of experimental bias, experimental noise, and inter-subject biological variability on the assessment of developmental trajectories in diffusion MRI studies of the brain.

    PubMed

    Sadeghi, Neda; Nayak, Amritha; Walker, Lindsay; Okan Irfanoglu, M; Albert, Paul S; Pierpaoli, Carlo

    2015-04-01

    Metrics derived from the diffusion tensor, such as fractional anisotropy (FA) and mean diffusivity (MD) have been used in many studies of postnatal brain development. A common finding of previous studies is that these tensor-derived measures vary widely even in healthy populations. This variability can be due to inherent inter-individual biological differences as well as experimental noise. Moreover, when comparing different studies, additional variability can be introduced by different acquisition protocols. In this study we examined scans of 61 individuals (aged 4-22 years) from the NIH MRI study of normal brain development. Two scans were collected with different protocols (low and high resolution). Our goal was to separate the contributions of biological variability and experimental noise to the overall measured variance, as well as to assess potential systematic effects related to the use of different protocols. We analyzed FA and MD in seventeen regions of interest. We found that biological variability for both FA and MD varies widely across brain regions; biological variability is highest for FA in the lateral part of the splenium and body of the corpus callosum along with the cingulum and the superior longitudinal fasciculus, and for MD in the optic radiations and the lateral part of the splenium. These regions with high inter-individual biological variability are the most likely candidates for assessing genetic and environmental effects in the developing brain. With respect to protocol-related effects, the lower resolution acquisition resulted in higher MD and lower FA values for the majority of regions compared with the higher resolution protocol. However, the majority of the regions did not show any age-protocol interaction, indicating similar trajectories were obtained irrespective of the protocol used. Published by Elsevier Inc.

  4. A Field Comparison of Sampling Protocols for Measuring Lead in Drinking Water

    EPA Science Inventory

    US EPA Region 5 conducted a sampling study that demonstrates existing sampling protocols used for the Lead and Copper Rule (LCR) underestimate peak and probable mass of lead released in a system with lead service lines (LSLs). This comparative stagnation sampling was conducted i...

  5. Measuring prefrontal cortical activity during dual task walking in patients with Parkinson's disease: feasibility of using a new portable fNIRS device.

    PubMed

    Nieuwhof, Freek; Reelick, Miriam F; Maidan, Inbal; Mirelman, Anat; Hausdorff, Jeffrey M; Olde Rikkert, Marcel G M; Bloem, Bastiaan R; Muthalib, Makii; Claassen, Jurgen A H R

    2016-01-01

    Many patients with Parkinson's disease (PD) have difficulties in performing a second task during walking (i.e., dual task walking). Functional near-infrared spectroscopy (fNIRS) is a promising approach to study the presumed contribution of dysfunction within the prefrontal cortex (PFC) to such difficulties. In this pilot study, we examined the feasibility of using a new portable and wireless fNIRS device to measure PFC activity during different dual task walking protocols in PD. Specifically, we tested whether PD patients were able to perform the protocol and whether we were able to measure the typical fNIRS signal of neuronal activity. We included 14 PD patients (age 71.2 ± 5.4 years, Hoehn and Yahr stage II/III). The protocol consisted of five repetitions of three conditions: walking while (i) counting forwards, (ii) serially subtracting, and (iii) reciting digit spans. Ability to complete this protocol, perceived exertion, burden of the fNIRS devices, and concentrations of oxygenated (O 2 Hb) and deoxygenated (HHb) hemoglobin from the left and right PFC were measured. Two participants were unable to complete the protocol due to fatigue and mobility safety concerns. The remaining 12 participants experienced no burden from the two fNIRS devices and completed the protocol with ease. Bilateral PFC O 2 Hb concentrations increased during walking while serially subtracting (left PFC 0.46 μmol/L, 95 % confidence interval (CI) 0.12-0.81, right PFC 0.49 μmol/L, 95 % CI 0.14-0.84) and reciting digit spans (left PFC 0.36 μmol/L, 95 % CI 0.03-0.70, right PFC 0.44 μmol/L, 95 % CI 0.09-0.78) when compared to rest. HHb concentrations did not differ between the walking tasks and rest. These findings suggest that a new wireless fNIRS device is a feasible measure of PFC activity in PD during dual task walking. Future studies should reduce the level of noise and inter-individual variability to enable measuring differences in PFC activity between different dual walking conditions and across health states.

  6. Clinical outcomes and mortality before and after implementation of a pediatric sepsis protocol in a limited resource setting: A retrospective cohort study in Bangladesh

    PubMed Central

    Axelrod, David M.; Chisti, Mohammod J.; Kache, Saraswati

    2017-01-01

    Background Pediatric sepsis has a high mortality rate in limited resource settings. Sepsis protocols have been shown to be a cost-effective strategy to improve morbidity and mortality in a variety of populations and settings. At Dhaka Hospital in Bangladesh, mortality from pediatric sepsis in high-risk children previously approached 60%, which prompted the implementation of an evidenced-based protocol in 2010. The clinical effectiveness of this protocol had not been measured. We hypothesized that implementation of a pediatric sepsis protocol improved clinical outcomes, including reducing mortality and length of hospital stay. Materials and methods This was a retrospective cohort study of children 1–59 months old with a diagnosis of sepsis, severe sepsis or septic shock admitted to Dhaka Hospital from 10/25/2009-10/25/2011. The primary outcome was inpatient mortality pre- and post-protocol implementation. Secondary outcomes included fluid overload, heart failure, respiratory insufficiency, length of hospital stay, and protocol compliance, as measured by antibiotic and fluid bolus administration within 60 minutes of hospital presentation. Results 404 patients were identified by a key-word search of the electronic medical record; 328 patients with a primary diagnosis of sepsis, severe sepsis, or septic shock were included (143 pre- and185 post-protocol) in the analysis. Pre- and post-protocol mortality were similar and not statistically significant (32.17% vs. 34.59%, p = 0.72). The adjusted odds ratio (AOR) for post-protocol mortality was 1.55 (95% CI, 0.88–2.71). The odds for developing fluid overload were significantly higher post-protocol (AOR 3.45, 95% CI, 2.04–5.85), as were the odds of developing heart failure (AOR 4.52, 95% CI, 1.43–14.29) and having a longer median length of stay (AOR 1.81, 95% CI 1.10–2.96). There was no statistically significant difference in respiratory insufficiency (pre- 65.7% vs. post- 70.3%, p = 0.4) or antibiotic administration between the cohorts (pre- 16.08% vs. post- 12.43%, p = 0.42). Conclusions Implementation of a pediatric sepsis protocol did not improve all-cause mortality or length of stay and may have been associated with increased fluid overload and heart failure during the study period in a large, non-governmental hospital in Bangladesh. Similar rates of early antibiotic administration may indicate poor protocol compliance. Though evidenced-based protocols are a potential cost-effective strategy to improve outcomes, future studies should focus on optimal implementation of context-relevant sepsis protocols in limited resource settings. PMID:28753618

  7. SeaWiFS technical report series. Volume 25: Ocean optics protocols for SeaWiFS validation, revision 1

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Acker, James G. (Editor); Mueller, James L.; Austin, Roswell W.

    1995-01-01

    This report presents protocols for measuring optical properties, and other environmental variables, to validate the radiometric performance of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), and to develop and validate bio-optical algorithms for use with SeaWiFS data. The protocols are intended to establish foundations for a measurement strategy to verify the challenging SeaWiFS uncertainty goals of 5 percent in water-leaving radiances and 35 percent in chlorophyll alpha concentration. The protocols first specify the variables which must be measured, and briefly review the rationale for measuring each variable. Subsequent chapters cover detailed protocols for instrument performance specifications, characterizing and calibrating instruments, methods of making measurements in the field, and methods of data analysis. These protocols were developed at a workshop sponsored by the SeaWiFS Project Office (SPO) and held at the Naval Postgraduate School in Monterey, California (9-12 April 1991). This report began as the proceedings of the workshop, as interpreted and expanded by the authors and reviewed by workshop participants and other members of the bio-optical research community. The protocols are an evolving prescription to allow the research community to approach the unprecedented measurement uncertainties implied by the SeaWiFS goals; research and development are needed to improve the state-of-the-art in specific areas. These protocols should be periodically revised to reflect technical advances during the SeaWiFS Project cycle. The present edition (Revision 1) incorporates new protocols in several areas, including expanded protocol descriptions for Case-2 waters and other improvements, as contributed by several members of the SeaWiFS Science Team.

  8. Variation of quantitative emphysema measurements from CT scans

    NASA Astrophysics Data System (ADS)

    Keller, Brad M.; Reeves, Anthony P.; Henschke, Claudia I.; Barr, R. Graham; Yankelevitz, David F.

    2008-03-01

    Emphysema is a lung disease characterized by destruction of the alveolar air sacs and is associated with long-term respiratory dysfunction. CT scans allow for imaging of the anatomical basis of emphysema, and several measures have been introduced for the quantification of the extent of disease. In this paper we compare these measures for repeatability over time. The measures of interest in this study are emphysema index, mean lung density, histogram percentile, and the fractal dimension. To allow for direct comparisons, the measures were normalized to a 0-100 scale. These measures have been computed for a set of 2,027 scan pairs in which the mean interval between scans was 1.15 years (σ: 93 days). These independent pairs were considered with respect to three different scanning conditions (a) 223 pairs where both were scanned with a 5 mm slice thickness protocol, (b) 695 with the first scanned with the 5 mm protocol and the second with a 1.25 mm protocol, and (c) 1109 pairs scanned both times using a 1.25 mm protocol. We found that average normalized emphysema index and histogram percentiles scores increased by 5.9 and 11 points respectively, while the fractal dimension showed stability with a mean difference of 1.2. We also found, a 7 point bias introduced for emphysema index under condition (b), and that the fractal dimension measure is least affected by scanner parameter changes.

  9. Who's really hypertensive?--Quality control issues in the assessment of blood pressure for randomized trials.

    PubMed

    Reid, Christopher M; Ryan, Philip; Miles, Helen; Willson, Kristyn; Beilin, Laurence J; Brown, Mark A; Jennings, Garry L; Johnston, Colin I; Macdonald, Graham J; Marley, John E; McNeil, John J; Morgan, Trefor O; West, Malcolm J; Wing, Lindon M H

    2005-01-01

    The characterization of blood pressure in treatment trials assessing the benefits of blood pressure lowering regimens is a critical factor for the appropriate interpretation of study results. With numerous operators involved in the measurement of blood pressure in many thousands of patients being screened for entry into clinical trials, it is essential that operators follow pre-defined measurement protocols involving multiple measurements and standardized techniques. Blood pressure measurement protocols have been developed by international societies and emphasize the importance of appropriate choice of cuff size, identification of Korotkoff sounds, and digit preference. Training of operators and auditing of blood pressure measurement may assist in reducing the operator-related errors in measurement. This paper describes the quality control activities adopted for the screening stage of the 2nd Australian National Blood Pressure Study (ANBP2). ANBP2 is cardiovascular outcome trial of the treatment of hypertension in the elderly that was conducted entirely in general practices in Australia. A total of 54 288 subjects were screened; 3688 previously untreated subjects were identified as having blood pressure >140/90 mmHg at the initial screening visit, 898 (24%) were not eligible for study entry after two further visits due to the elevated reading not being sustained. For both systolic and diastolic blood pressure recording, observed digit preference fell within 7 percentage points of the expected frequency. Protocol adherence, in terms of the required minimum blood pressure difference between the last two successive recordings, was 99.8%. These data suggest that adherence to blood pressure recording protocols and elimination of digit preferences can be achieved through appropriate training programs and quality control activities in large multi-centre community-based trials in general practice. Repeated blood pressure measurement prior to initial diagnosis and study entry is essential to appropriately characterize hypertension in these elderly patients.

  10. The Effect of the Dynamic Skills Protocol RTI Model on Reading Achievement in an Elementary School and the Predictive Validity of Phonics Screening Measures Implemented in the Model

    ERIC Educational Resources Information Center

    Laben, Joyce

    2012-01-01

    With the implementation of RTI, educators are attempting to find models that are the best fit for their schools. The problem solving and standard protocol models are the two most common. This study of 65 students examines a new model, the dynamic skills protocol implemented in an elementary school starting in their fourth quarter of kindergarten…

  11. Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Crawford, Aladsair J.; Fuller, Jason C.

    The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL 22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol,more » this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance.« less

  12. An extended protocol for usability validation of medical devices: Research design and reference model.

    PubMed

    Schmettow, Martin; Schnittker, Raphaela; Schraagen, Jan Maarten

    2017-05-01

    This paper proposes and demonstrates an extended protocol for usability validation testing of medical devices. A review of currently used methods for the usability evaluation of medical devices revealed two main shortcomings. Firstly, the lack of methods to closely trace the interaction sequences and derive performance measures. Secondly, a prevailing focus on cross-sectional validation studies, ignoring the issues of learnability and training. The U.S. Federal Drug and Food Administration's recent proposal for a validation testing protocol for medical devices is then extended to address these shortcomings: (1) a novel process measure 'normative path deviations' is introduced that is useful for both quantitative and qualitative usability studies and (2) a longitudinal, completely within-subject study design is presented that assesses learnability, training effects and allows analysis of diversity of users. A reference regression model is introduced to analyze data from this and similar studies, drawing upon generalized linear mixed-effects models and a Bayesian estimation approach. The extended protocol is implemented and demonstrated in a study comparing a novel syringe infusion pump prototype to an existing design with a sample of 25 healthcare professionals. Strong performance differences between designs were observed with a variety of usability measures, as well as varying training-on-the-job effects. We discuss our findings with regard to validation testing guidelines, reflect on the extensions and discuss the perspectives they add to the validation process. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols.

    PubMed

    Forst, Darren; Nijjar, Simrit; Flores-Mir, Carlos; Carey, Jason; Secanell, Marc; Lagravere, Manuel

    2014-12-23

    The objective of this study is to analyze a set of previously developed and proposed image segmentation protocols for precision in both intra- and inter-rater reliability for in vivo tooth volume measurements using cone-beam computed tomography (CBCT) images. Six 3D volume segmentation procedures were proposed and tested for intra- and inter-rater reliability to quantify maxillary first molar volumes. Ten randomly selected maxillary first molars were measured in vivo in random order three times with 10 days separation between measurements. Intra- and inter-rater agreement for all segmentation procedures was attained using intra-class correlation coefficient (ICC). The highest precision was for automated thresholding with manual refinements. A tooth volume measurement protocol for CBCT images employing automated segmentation with manual human refinement on a 2D slice-by-slice basis in all three planes of space possessed excellent intra- and inter-rater reliability. Three-dimensional volume measurements of the entire tooth structure are more precise than 3D volume measurements of only the dental roots apical to the cemento-enamel junction (CEJ).

  14. Comparison of the ultrashort gonadotropin-releasing hormone agonist-antagonist protocol with microdose flare -up protocol in poor responders: a preliminary study

    PubMed Central

    Berker, Bülent; Duvan, Candan İltemir; Kaya, Cemil; Aytaç, Ruşen; Şatıroğlu, Hakan

    2010-01-01

    Objective To determine the potential effect of the ultrashort gonadotropin-releasing hormone (GnRH) agonist/GnRH antagonist protocol versus the microdose GnRH agonist protocol in poor responders undergoing intracytoplasmic sperm injection (ICSI). Material and Methods The patients in the Agonist-Antagonist Group (n=41) were administered the ultrashort GnRH-agonist/ antagonist protocol, while the patients in the Microdose Group (n=41) were stimulated according to the microdose flare-up protocol. The mean number of mature oocytes retrieved was the primary outcome measure. Fertilization rate, implantation rate per embryo and clinical pregnancy rates were secondary outcome measures. Results There was no differenc between the mean number of mature oocytes retrieved in the two groups. There were also no statistical differences between the two groups in terms of peak serum E2 level, canceled cycles, endometrial thickness on hCG day, number of 2 pronucleus and number of embryos transferred. However, the total gonadotropin consumption and duration of stimulation were significantly higher with the Agonist-Antagonist Group compared with the Microdose Group. The implantation and clinical pregnancy rates were similar between the two groups. Conclusion Despite the high dose of gonadotropin consumption and longer duration of stimulation with the ultrashort GnRH agonist/ antagonist protocol, it seems that the Agonist-Antagonist Protocol is not inferior to the microdose protocol in poor responders undergoing ICSI. PMID:24591934

  15. Cost savings using a protocol approach to manage anemia in a hemodialysis unit.

    PubMed

    Charlesworth, Emily C; Richardson, Robert M; Battistella, Marisa

    2014-01-01

    National guidelines recommend using anemia management protocols to guide treatment. The objective of this study was to determine if an anemia management protocol would improve hemoglobin (Hgb) indices in hemodialysis patients and to measure whether the protocol would reduce the use and cost of darbepoetin alfa (DBO) and intravenous (IV) iron in hemodialysis patients. An anemia management protocol was created and implemented for hemodialysis patients at our institution. A retrospective observational review of the use of DBO and IV iron as well as changes in Hgb, transferrin saturation and ferritin in 174 patients was conducted 6 months before and after implementation of the anemia protocol. The number of Hgb measurements in the target range increased from 44.3 to 46.0% (p = 0.48) after protocol implementation. The mean weekly dose of DBO was reduced from 34.56 ± 31.12 to 31.11 ± 28.64 μg post-protocol implementation (p = 0.011), which translated to a cost savings of USD 41,649 over 6 months. The mean monthly IV iron dose also decreased from 139.56 ± 98.83 to 97.65 ± 79.05 mg (p < 0.005), a cost savings of USD 18,594 over the same time period. The use of an anemia management protocol resulted in the deprescribing of DBO and iron agents while increasing the number of patients in the target Hgb range, which led to significant cost savings in the treatment of anemia.

  16. Monitoring changes in membrane polarity, membrane integrity, and intracellular ion concentrations in Streptococcus pneumoniae using fluorescent dyes.

    PubMed

    Clementi, Emily A; Marks, Laura R; Roche-Håkansson, Hazeline; Håkansson, Anders P

    2014-02-17

    Membrane depolarization and ion fluxes are events that have been studied extensively in biological systems due to their ability to profoundly impact cellular functions, including energetics and signal transductions. While both fluorescent and electrophysiological methods, including electrode usage and patch-clamping, have been well developed for measuring these events in eukaryotic cells, methodology for measuring similar events in microorganisms have proven more challenging to develop given their small size in combination with the more complex outer surface of bacteria shielding the membrane. During our studies of death-initiation in Streptococcus pneumoniae (pneumococcus), we wanted to elucidate the role of membrane events, including changes in polarity, integrity, and intracellular ion concentrations. Searching the literature, we found that very few studies exist. Other investigators had monitored radioisotope uptake or equilibrium to measure ion fluxes and membrane potential and a limited number of studies, mostly in Gram-negative organisms, had seen some success using carbocyanine or oxonol fluorescent dyes to measure membrane potential, or loading bacteria with cell-permeant acetoxymethyl (AM) ester versions of ion-sensitive fluorescent indicator dyes. We therefore established and optimized protocols for measuring membrane potential, rupture, and ion-transport in the Gram-positive organism S. pneumoniae. We developed protocols using the bis-oxonol dye DiBAC4(3) and the cell-impermeant dye propidium iodide to measure membrane depolarization and rupture, respectively, as well as methods to optimally load the pneumococci with the AM esters of the ratiometric dyes Fura-2, PBFI, and BCECF to detect changes in intracellular concentrations of Ca(2+), K(+), and H(+), respectively, using a fluorescence-detection plate reader. These protocols are the first of their kind for the pneumococcus and the majority of these dyes have not been used in any other bacterial species. Though our protocols have been optimized for S. pneumoniae, we believe these approaches should form an excellent starting-point for similar studies in other bacterial species.

  17. Return of postural control to baseline after anaerobic and aerobic exercise protocols.

    PubMed

    Fox, Zachary G; Mihalik, Jason P; Blackburn, J Troy; Battaglini, Claudio L; Guskiewicz, Kevin M

    2008-01-01

    With regard to sideline concussion testing, the effect of fatigue associated with different types of exercise on postural control is unknown. To evaluate the effects of fatigue on postural control in healthy college-aged athletes performing anaerobic and aerobic exercise protocols and to establish an immediate recovery time course from each exercise protocol for postural control measures to return to baseline status. Counterbalanced, repeated measures. Research laboratory. Thirty-six collegiate athletes (18 males, 18 females; age = 19.00 +/- 1.01 years, height = 172.44 +/- 10.47 cm, mass = 69.72 +/- 12.84 kg). Participants completed 2 counterbalanced sessions within 7 days. Each session consisted of 1 exercise protocol followed by postexercise measures of postural control taken at 3-, 8-, 13-, and 18-minute time intervals. Baseline measures were established during the first session, before the specified exertion protocol was performed. Balance Error Scoring System (BESS) results, sway velocity, and elliptical sway area. We found a decrease in postural control after each exercise protocol for all dependent measures. An interaction was noted between exercise protocol and time for total BESS score (P = .002). For both exercise protocols, all measures of postural control returned to baseline within 13 minutes. Postural control was negatively affected after anaerobic and aerobic exercise protocols as measured by total BESS score, elliptical sway area, and sway velocity. The effect of exertion lasted up to 13 minutes after each exercise was completed. Certified athletic trainers and clinicians should be aware of these effects and their recovery time course when determining an appropriate time to administer sideline assessments of postural control after a suspected mild traumatic brain injury.

  18. Risk of bias and confounding of observational studies of Zika virus infection: A scoping review of research protocols

    PubMed Central

    Haby, Michelle M.; Martínez-Vega, Ruth; Pinzón-Flores, Carlos E.; Smith, Emma; Pinart, Mariona; Broutet, Nathalie; Becerra-Posada, Francisco; Aldighieri, Sylvain; Van Kerkhove, Maria D.

    2017-01-01

    Introduction Given the severity and impact of the current Zika virus (ZIKV) outbreak in the Americas, numerous countries have rushed to develop research studies to assess ZIKV and its potential health consequences. In an effort to ensure that studies are comprehensive, both internally and externally valid, and with reliable results, the World Health Organization, the Pan American Health Organization, Institut Pasteur, the networks of Fiocruz, the Consortia for the Standardization of Influenza Seroepidemiology (CONSISE) and the International Severe Acute Respiratory and Emerging Infection Consortium (ISARIC) have generated six standardized clinical and epidemiological research protocols and questionnaires to address key public health questions on ZIKV. Methods We conducted a systematic search of ongoing study protocols related to ZIKV research. We analyzed the content of protocols of 32 cohort studies and 13 case control studies for systematic bias that could produce erroneous results. Additionally we aimed to characterize the risks of bias and confounding in observational studies related to ZIKV and to propose ways to minimize them, including the use of six newly standardized research protocols. Results Observational studies of ZIKV face an array of challenges, including measurement of exposure and outcomes (microcephaly and Guillain-Barré Syndrome). Potential confounders need to be measured where known and controlled for in the analysis. Selection bias due to non-random selection is a significant issue, particularly in the case-control design, and losses to follow-up is equally important for the cohort design. Conclusion Observational research seeking to answer key questions on the ZIKV should consider these restrictions and take precautions to minimize bias in an effort to provide reliable and valid results. Utilization of the standardized research protocols developed by the WHO, PAHO, Institut Pasteur, and CONSISE will harmonize the key methodological aspects of each study design to minimize bias at different stages of the study. Biases need to be considered by researchers implementing the standardized protocols as well as by users of observational epidemiological studies of ZIKV. PMID:28686621

  19. Tiered protocol implementation improves treatment of hypoglycaemia in a neurosciences critical care and surgical intensive care unit.

    PubMed

    Van Berkel, Megan A; MacDermott, Jennifer; Dungan, Kathleen M; Cook, Charles H; Murphy, Claire V

    2017-12-01

    Although studies demonstrate techniques to limit hypoglycaemia in critically ill patients, there are limited data supporting methods to improve management of existing hypoglycaemia. Assess the impact and sustainability of a computerised, three tiered, nurse driven protocol for hypoglycaemia treatment. Retrospective pre and post protocol study. Neurosciences and surgical intensive care units at a tertiary academic medical centre. Patients with a hypoglycaemic episode were included during a pre-protocol or post-protocol implementation period. An additional six-month cohort was evaluated to assess sustainability. Fifty-four patients were included for evaluation (35 pre- and 19 post-protocol); 122 patients were included in the sustainability cohort. Hypoglycaemia treatment significantly improved in the post-protocol cohort (20% vs. 52.6%, p=0.014); with additional improvement to 79.5% in the sustainability cohort. Time to follow-up blood glucose was decreased after treatment from 122 [Q1-Q3: 46-242] minutes pre-protocol to 25 [Q1-Q3: 9-48] minutes post protocol (p<0.0001). This reduction was maintained in the sustainability cohort [median of 29min (Q1-Q3: 20-51)]. Implementation of a nurse-driven, three-tiered protocol for treatment of hypoglyacemia significantly improved treatment rates, as well as reduced time to recheck blood glucose measurement. These benefits were sustained during a six-month period after protocol implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Who needs inpatient detox? Development and implementation of a hospitalist protocol for the evaluation of patients for alcohol detoxification.

    PubMed

    Stephens, John R; Liles, E Allen; Dancel, Ria; Gilchrist, Michael; Kirsch, Jonathan; DeWalt, Darren A

    2014-04-01

    Clinicians caring for patients seeking alcohol detoxification face many challenges, including lack of evidence-based guidelines for treatment and high recidivism rates. To develop a standardized protocol for determining which alcohol dependent patients seeking detoxification need inpatient versus outpatient treatment, and to study the protocol's implementation. Review of best evidence by ad hoc task force and subsequent creation of standardized protocol. Prospective observational evaluation of initial protocol implementation. Patients presenting for alcohol detoxification. Development and implementation of a protocol for evaluation and treatment of patients requesting alcohol detoxification. Number of admissions per month with primary alcohol related diagnosis (DRG), 30-day readmission rate, and length of stay, all measured before and after protocol implementation. We identified one randomized clinical trial and three cohort studies to inform the choice of inpatient versus outpatient detoxification, along with one prior protocol in this population, and combined that data with clinical experience to create an institutional protocol. After implementation, the average number of alcohol related admissions was 15.9 per month, compared with 18.9 per month before implementation (p = 0.037). There was no difference in readmission rate or length of stay. Creation and utilization of a protocol led to standardization of care for patients requesting detoxification from alcohol. Initial evaluation of protocol implementation showed a decrease in number of admissions.

  1. Protocols and Hospital Mortality in Critically ill Patients: The United States Critical Illness and Injury Trials Group Critical Illness Outcomes Study

    PubMed Central

    Sevransky, Jonathan E.; Checkley, William; Herrera, Phabiola; Pickering, Brian W.; Barr, Juliana; Brown, Samuel M; Chang, Steven Y; Chong, David; Kaufman, David; Fremont, Richard D; Girard, Timothy D; Hoag, Jeffrey; Johnson, Steven B; Kerlin, Mehta P; Liebler, Janice; O'Brien, James; O'Keefe, Terence; Park, Pauline K; Pastores, Stephen M; Patil, Namrata; Pietropaoli, Anthony P; Putman, Maryann; Rice, Todd W.; Rotello, Leo; Siner, Jonathan; Sajid, Sahul; Murphy, David J; Martin, Greg S

    2015-01-01

    Objective Clinical protocols may decrease unnecessary variation in care and improve compliance with desirable therapies. We evaluated whether highly protocolized intensive care units have superior patient outcomes compared with less highly protocolized intensive care units. Design Observational study in which participating intensive care units completed a general assessment and enrolled new patients one day each week. Setting and Patients 6179 critically ill patients across 59 intensive care units in the United States Critical Illness and Injury Trials Group Critical Illness Outcomes Study Interventions: None Measurements and Main Results The primary exposure was the number of intensive care unit protocols; the primary outcome was hospital mortality. 5809 participants were followed prospectively and 5454 patients in 57 intensive care units had complete outcome data. The median number of protocols per intensive care unit was 19 (IQR 15 to 21.5). In single variable analyses, there were no differences in intensive care unit and hospital mortality, length of stay, use of mechanical ventilation, vasopressors, or continuous sedation among individuals in intensive care units with a high vs. low number of protocols. The lack of association was confirmed in adjusted multivariable analysis (p=0.70). Protocol compliance with two ventilator management protocols was moderate and did not differ between intensive care units with high vs. low numbers of protocols for lung protective ventilation in ARDS (47% vs. 52%; p=0.28) and for spontaneous breathing trials (55% vs. 51%; p=0.27). Conclusions Clinical protocols are highly prevalent in United States intensive care units. The presence of a greater number of protocols was not associated with protocol compliance or patient mortality. PMID:26110488

  2. Estimation of non-solid lung nodule volume with low-dose CT protocols: effect of reconstruction algorithm and measurement method

    NASA Astrophysics Data System (ADS)

    Gavrielides, Marios A.; DeFilippo, Gino; Berman, Benjamin P.; Li, Qin; Petrick, Nicholas; Schultz, Kurt; Siegelman, Jenifer

    2017-03-01

    Computed tomography is primarily the modality of choice to assess stability of nonsolid pulmonary nodules (sometimes referred to as ground-glass opacity) for three or more years, with change in size being the primary factor to monitor. Since volume extracted from CT is being examined as a quantitative biomarker of lung nodule size, it is important to examine factors affecting the performance of volumetric CT for this task. More specifically, the effect of reconstruction algorithms and measurement method in the context of low-dose CT protocols has been an under-examined area of research. In this phantom study we assessed volumetric CT with two different measurement methods (model-based and segmentation-based) for nodules with radiodensities of both nonsolid (-800HU and -630HU) and solid (-10HU) nodules, sizes of 5mm and 10mm, and two different shapes (spherical and spiculated). Imaging protocols included CTDIvol typical of screening (1.7mGy) and sub-screening (0.6mGy) scans and different types of reconstruction algorithms across three scanners. Results showed that radio-density was the factor contributing most to overall error based on ANOVA. The choice of reconstruction algorithm or measurement method did not affect substantially the accuracy of measurements; however, measurement method affected repeatability with repeatability coefficients ranging from around 3-5% for the model-based estimator to around 20-30% across reconstruction algorithms for the segmentation-based method. The findings of the study can be valuable toward developing standardized protocols and performance claims for nonsolid nodules.

  3. Validation of the BPLab(®) 24-hour blood pressure monitoring system according to the European standard BS EN 1060-4:2004 and British Hypertension Society protocol.

    PubMed

    Koudryavtcev, Sergey A; Lazarev, Vyacheslav M

    2011-01-01

    Automatic blood pressure (BP) measuring devices are more and more often used in BP self-checks and in 24-hour BP monitoring. Nowadays, 24-hour BP monitoring is a necessary procedure in arterial hypertension treatment. The aim of this study was to validate the BPLab(®) ambulatory blood pressure monitor according to the European standard BS EN 1060-4:2004 and the British Hypertension Society (BHS) protocol, as well as to work out solutions regarding the suitability of using this device in clinical practice. A group of 85 patients of both sexes and different ages, who voluntarily agreed to take part in the tests and were given detailed instructions on the measurement technique were recruited for this study. The results of the BP measurement obtained by a qualified operator using the BPLab(®) device were compared with the BP values measured using the Korotkov auscultatory method. Data were obtained simultaneously by two experts with experience of over 10 years and had completed a noninvasive BP measurement standardization training course. Discrepancies in the systolic and diastolic BP measurements (N = 510; 255 for each expert) were analyzed according to the criteria specified in the BHS-93 protocol. The device passed the requirements of the European Standard BS EN 1060-4:2004 and was graded 'A' according to the criteria of the BHS protocol for both systolic BP and diastolic BP. The BPLab(®) 24-hour ambulatory blood pressure monitoring device may be recommended for extensive clinical use.

  4. Adaptive tracking of a time-varying field with a quantum sensor

    NASA Astrophysics Data System (ADS)

    Bonato, Cristian; Berry, Dominic W.

    2017-05-01

    Sensors based on single spins can enable magnetic-field detection with very high sensitivity and spatial resolution. Previous work has concentrated on sensing of a constant magnetic field or a periodic signal. Here, we instead investigate the problem of estimating a field with nonperiodic variation described by a Wiener process. We propose and study, by numerical simulations, an adaptive tracking protocol based on Bayesian estimation. The tracking protocol updates the probability distribution for the magnetic field based on measurement outcomes and adapts the choice of sensing time and phase in real time. By taking the statistical properties of the signal into account, our protocol strongly reduces the required measurement time. This leads to a reduction of the error in the estimation of a time-varying signal by up to a factor of four compare with protocols that do not take this information into account.

  5. Intensive Sensorimotor Arm Training Mediated by Therapist or Robot Improves Hemiparesis in Patients With Chronic Stroke

    PubMed Central

    Volpe, Bruce T.; Lynch, Daniel; Rykman-Berland, Avrielle; Ferraro, Mark; Galgano, Michael; Hogan, Neville; Krebs, Hermano I.

    2016-01-01

    Investigators have demonstrated that a variety of intensive movement training protocols for persistent upper limb paralysis in patients with chronic stroke (6 months or more after stroke) improve motor outcome. This randomized controlled study determined in patients with upper limb motor impairment after chronic stroke whether movement therapy delivered by a robot or by a therapist using an intensive training protocol was superior. Robotic training (n = 11) and an intensive movement protocol (n = 10) improved the impairment measures of motor outcome significantly and comparably; there were no significant changes in disability measures. Motor gains were maintained at the 3-month evaluation after training. These data contribute to the growing awareness that persistent impairments in those with chronic stroke may not reflect exhausted capacity for improvement. These new protocols, rendered by either therapist or robot, can be standardized, tested, and replicated, and potentially will contribute to rational activity-based programs. PMID:18184932

  6. Submaximal delayed-onset muscle soreness: correlations between MR imaging findings and clinical measures

    NASA Technical Reports Server (NTRS)

    Evans, G. F.; Haller, R. G.; Wyrick, P. S.; Parkey, R. W.; Fleckenstein, J. L.; Blomqvist, C. G. (Principal Investigator)

    1998-01-01

    PURPOSE: To assess correlations between muscle edema on magnetic resonance (MR) images and clinical indexes of muscle injury in delayed-onset muscle soreness (DOMS) produced by submaximal exercise protocols. MATERIALS AND METHODS: Sixteen subjects performed 36 elbow flexions ("biceps curls") at one of two submaximal workloads that emphasized eccentric contractions. Changes in MR imaging findings, plasma levels of creatine kinase, and pain scores were correlated. RESULTS: Both exercise protocols produced DOMS in all subjects. The best correlation was between change in creatine kinase level and volume of muscle edema on MR images, regardless of the workload. Correlations tended to be better with the easier exercise protocol. CONCLUSION: Whereas many previous studies of DOMS focused on intense exercise protocols to ensure positive results, the present investigation showed that submaximal workloads are adequate to produce DOMS and that correlations between conventionally measured indexes of injury may be enhanced at lighter exercise intensities.

  7. Comparison of the efficiency of rat papillary muscles during afterloaded isotonic contractions and contractions with sinusoidal length changes.

    PubMed

    Mellors, L J; Gibbs, C L; Barclay, C J

    2001-05-01

    The results of previous studies suggest that the maximum mechanical efficiency of rat papillary muscles is lower during a contraction protocol involving sinusoidal length changes than during one involving afterloaded isotonic contractions. The aim of this study was to compare directly the efficiency of isolated rat papillary muscle preparations in isotonic and sinusoidal contraction protocols. Experiments were performed in vitro (27 degrees C) using left ventricular papillary muscles from adult rats. Each preparation performed three contraction protocols: (i) low-frequency afterloaded isotonic contractions (10 twitches at 0.2 Hz), (ii) sinusoidal length change contractions with phasic stimulation (40 twitches at 2 Hz) and (iii) high-frequency afterloaded isotonic contractions (40 twitches at 2 Hz). The first two protocols resembled those used in previous studies and the third combined the characteristics of the first two. The parameters for each protocol were adjusted to those that gave maximum efficiency. For the afterloaded isotonic protocols, the afterload was set to 0.3 of the maximum developed force. The sinusoidal length change protocol incorporated a cycle amplitude of +/-5% resting length and a stimulus phase of -10 degrees. Measurements of force output, muscle length change and muscle temperature change were used to calculate the work and heat produced during and after each protocol. Net mechanical efficiency was defined as the proportion of the energy (enthalpy) liberated by the muscle that appeared as work. The efficiency in the low-frequency, isotonic contraction protocol was 21.1+/-1.4% (mean +/- s.e.m., N=6) and that in the sinusoidal protocol was 13.2+/-0.7%, consistent with previous results. This difference was not due to the higher frequency or greater number of twitches because efficiency in the high-frequency, isotonic protocol was 21.5+/-1.0%. Although these results apparently confirm that efficiency is protocol-dependent, additional experiments designed to measure work output unambiguously indicated that the method used to calculate work output in isotonic contractions overestimated actual work output. When net work output, which excludes work done by parallel elastic elements, rather than total work output was used to determine efficiency in afterloaded isotonic contractions, efficiency was similar to that for sinusoidal contractions. The maximum net mechanical efficiency of rat papillary muscles performing afterloaded isotonic or sinusoidal length change contractions was between 10 and 15%.

  8. Evaluation of Patient Handoff Methods on an Inpatient Teaching Service

    PubMed Central

    Craig, Steven R.; Smith, Hayden L.; Downen, A. Matthew; Yost, W. John

    2012-01-01

    Background The patient handoff process can be a highly variable and unstructured period at risk for communication errors. The morning sign-in process used by resident physicians at teaching hospitals typically involves less rigorous handoff protocols than the resident evening sign-out process. Little research has been conducted on best practices for handoffs during morning sign-in exchanges between resident physicians. Research must evaluate optimal protocols for the resident morning sign-in process. Methods Three morning handoff protocols consisting of written, electronic, and face-to-face methods were implemented over 3 study phases during an academic year. Study participants included all interns covering the internal medicine inpatient teaching service at a tertiary hospital. Study measures entailed intern survey-based interviews analyzed for failures in handoff protocols with or without missed pertinent information. Descriptive and comparative analyses examined study phase differences. Results A scheduled face-to-face handoff process had the fewest protocol deviations and demonstrated best communication of essential patient care information between cross-covering teams compared to written and electronic sign-in protocols. Conclusion Intern patient handoffs were more reliable when the sign-in protocol included scheduled face-to-face meetings. This method provided the best communication of patient care information and allowed for open exchanges of information. PMID:23267259

  9. The acute effects of manipulating volume and load of back squats on countermovement vertical jump performance.

    PubMed

    Moir, Gavin L; Mergy, David; Witmer, Ca; Davis, Shala E

    2011-06-01

    The acute effects of manipulating the volume and load of back squats on subsequent countermovement vertical jump performance were investigated in the present study. Eleven National Collegiate Athletic Association division II female volleyball players performed 10 countermovement vertical jumps (CMJs) on a force platform 2 minutes after the last squat repetition of a high-load (HL) or high-volume (HV) squat protocol. Two minutes of rest was provided between each CMJ. The HL protocol culminated in the subjects having to perform 3 repetitions with a load equivalent to 90% 1 repetition maximum (1RM) back squat, whereas 12 repetitions with a load equivalent to 37% 1RM were performed in the HV protocol. During an initial familiarization session, knee angles were recorded during a series of CMJs, and these angles were used to control the depth of descent during all subsequent back squats. Jump height (JH) and vertical stiffness (VStiff) were calculated during each of the 10 CMJ, and the change in these variables after the 2 squat protocols was assessed using an analysis of variance model with repeated measures on 2 factors (Protocol [2-levels]; Time [2-levels]). There was no significant difference in JH after the HL and HV protocols (p > 0.05). A significant Protocol × Time interaction for VStiff resulted from the increase after the HL protocol being greater than that after the HV protocol (p = 0.03). The knee angles before the HL and HV protocols were significantly greater than those measured during the initial familiarization session (p = 0.001). Although neither squat protocol provided any benefit in improving JH, the heavy squat protocol produced greater increases in VStiff during the CMJ. Because of the increased VStiff caused by the HL protocol, volleyball coaches may consider using such protocols with their players to improve performance in jumps performed from a run such as the spike and on-court agility.

  10. Effect of cold air inhalation and isometric exercise on coronary blood flow and myocardial function in humans

    PubMed Central

    Muller, Matthew D.; Gao, Zhaohui; Drew, Rachel C.; Herr, Michael D.; Leuenberger, Urs A.

    2011-01-01

    The effects of cold air inhalation and isometric exercise on coronary blood flow are currently unknown, despite the fact that both cold air and acute exertion trigger angina in clinical populations. In this study, we used transthoracic Doppler echocardiography to measure coronary blood flow velocity (CBV; left anterior descending coronary artery) and myocardial function during cold air inhalation and handgrip exercise. Ten young healthy subjects underwent the following protocols: 5 min of inhaling cold air (cold air protocol), 5 min of inhaling thermoneutral air (sham protocol), 2 min of isometric handgrip at 30% of maximal voluntary contraction (grip protocol), and 5 min of isometric handgrip at 30% maximal voluntary contraction while breathing cold air (cold + grip protocol). Heart rate, blood pressure, inspired air temperature, CBV, myocardial function (tissue Doppler imaging), O2 saturation, and pulmonary function were measured. The rate-pressure product (RPP) was used as an index of myocardial O2 demand, whereas CBV was used as an index of myocardial O2 supply. Compared with the sham protocol, the cold air protocol caused a significantly higher RPP, but there was a significant reduction in CBV. The cold + grip protocol caused a significantly greater increase in RPP compared with the grip protocol (P = 0.045), but the increase in CBV was significantly less (P = 0.039). However, myocardial function was not impaired during the cold + grip protocol relative to the grip protocol alone. Collectively, these data indicate that there is a supply-demand mismatch in the coronary vascular bed when cold ambient air is breathed during acute exertion but myocardial function is preserved, suggesting an adequate redistribution of blood flow. PMID:21940852

  11. Assessment of neuromuscular function after different strength training protocols using tensiomyography.

    PubMed

    de Paula Simola, Rauno Á; Harms, Nico; Raeder, Christian; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander

    2015-05-01

    The purpose of the study was to analyze tensiomyography (TMG) sensitivity to changes in muscle force and neuromuscular function of the muscle rectus femoris (RF) using TMG muscle properties after 5 different lower-limb strength training protocols (multiple sets; DS = drop sets; eccentric overload; FW = flywheel; PL = plyometrics). After baseline measurements, 14 male strength trained athletes completed 1 squat training protocol per week over a 5-week period in a randomized controlled order. Maximal voluntary isometric contraction (MVIC), TMG measurements of maximal radial displacement of the muscle belly (Dm), contraction time between 10 and 90% of Dm (Tc), and mean muscle contraction velocities from the beginning until 10% (V10) and 90% of Dm (V90) were analyzed up to 0.5 (post-train), 24 (post-24), and 48 hours (post-48) after the training interventions. Significant analysis of variance main effects for measurement points were found for all TMG contractile properties and MVIC (p < 0.01). Dm and V10 post-train values were significantly lower after protocols DS and FW compared with protocol PL (p = 0.032 and 0.012, respectively). Dm, V10, and V90 decrements correlated significantly to the decreases in MVIC (r = 0.64-0.67, p ≤ 0.05). Some TMG muscle properties are sensitive to changes in muscle force, and different lower-limb strength training protocols lead to changes in neuromuscular function of RF. In addition, those protocols involving high and eccentric load and a high total time under tension may induce higher changes in TMG muscle properties.

  12. Regional gastrointestinal transit and pH studied in 215 healthy volunteers using the wireless motility capsule: influence of age, gender, study country and testing protocol.

    PubMed

    Wang, Y T; Mohammed, S D; Farmer, A D; Wang, D; Zarate, N; Hobson, A R; Hellström, P M; Semler, J R; Kuo, B; Rao, S S; Hasler, W L; Camilleri, M; Scott, S M

    2015-09-01

    The wireless motility capsule (WMC) offers the ability to investigate luminal gastrointestinal (GI) physiology in a minimally invasive manner. To investigate the effect of testing protocol, gender, age and study country on regional GI transit times and associated pH values using the WMC. Regional GI transit times and pH values were determined in 215 healthy volunteers from USA and Sweden studied using the WMC over a 6.5-year period. The effects of test protocol, gender, age and study country were examined. For GI transit times, testing protocol was associated with differences in gastric emptying time (GET; shorter with protocol 2 (motility capsule ingested immediately after meal) vs. protocol 1 (motility capsule immediately before): median difference: 52 min, P = 0.0063) and colonic transit time (CTT; longer with protocol 2: median 140 min, P = 0.0189), but had no overall effect on whole gut transit time. Females had longer GET (by median 17 min, P = 0.0307), and also longer CTT by (104 min, P = 0.0285) and whole gut transit time by (263 min, P = 0.0077). Increasing age was associated with shorter small bowel transit time (P = 0.002), and study country also influenced small bowel and CTTs. Whole gut and CTTs showed clustering of data at values separated by 24 h, suggesting that describing these measures as continuous variables is invalid. Testing protocol, gender and study country also significantly influenced pH values. Regional GI transit times and pH values, delineated using the wireless motility capsule (WMC), vary based on testing protocol, gender, age and country. Standardisation of testing is crucial for cross-referencing in clinical practice and future research. © 2015 John Wiley & Sons Ltd.

  13. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    PubMed

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  14. [Determination of absorbed dose to water for high energy photon and electron beams--comparison of different dosimetry protocols].

    PubMed

    Zakaria, Golam Abu; Schütte, Wilhelm

    2003-01-01

    The determination of absorbed dose to water for high-energy photon and electron beams is performed in Germany according to the dosimetry protocol DIN 6800-2 (1997). At an international level, the main protocols used are the AAPM dosimetry protocol TG-51 (1999) and the IAEA Code of Practice TRS-398 (2000). The present paper systematically compares these three dosimetry protocols, and identifies similarities and differences. The investigations were performed using 4 and 10 MV photon beams, as well as 6, 8, 9, 10, 12 and 14 MeV electron beams. Two cylindrical and two plane-parallel type chambers were used for measurements. In general, the discrepancies among the three protocols were 1.0% for photon beams and 1.6% for electron beams. Comparative measurements in the context of measurement technical control (MTK) with TLD showed a deviation of less than 1.3% between the measurements obtained according to protocols DIN 6800-2 and MTK (exceptions: 4 MV photons with 2.9% and 6 MeV electrons with 2.4%). While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using both cylindrical and plane-parallel chambers (the latter used after a cross-calibration to a cylindrical chamber, as required by the respective dosimetry protocols). Notably, unlike recommended in the corresponding protocols, we found out that cylindrical chambers can be used also for energies from 6 to 10 MeV.

  15. The reliability of knee joint position testing using electrogoniometry

    PubMed Central

    Piriyaprasarth, Pagamas; Morris, Meg E; Winter, Adele; Bialocerkowski, Andrea E

    2008-01-01

    Background The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric® electrogoniometer. The clinical utility of electrogoniometry was also addressed. Methods The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. Results In the first study, inter-tester reliability (ICC[2,10]) ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC[3,10]) ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. Conclusion Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer. PMID:18211714

  16. [Patients' perspective and economic variables as objectives in clinical trials: added value to clinical parameters].

    PubMed

    Bovaira-García, M J; Soler-Company, E

    2012-01-01

    Patient-reported outcome (PRO) measures complement traditional biomedical outcome measures. The purpose of this study was to evaluate the use of PRO measures including health-related quality of life (HRQoL) questionnaires as a measurement of efficacy and the frequency of inclusion of economic variables related to direct and indirect costs in the design of clinical trials and phase IV observational studies. Moreover, for the trials quality score were measured, and if there were any relationship between the quality study design score and the PRO inclusion. Retrospective observational study of the clinical trials and phase IV observational studies approved by a Clinical Research Ethics Committee (2008-2010). We gathered data concerning general aspects including medical specialty, pathology, methodological quality based on Jadad scale (0-5), inclusion of PRO and economic variables. For clinical trials including HRQoL measurements, we analysed the type of questionnaire in use. Where there were no HRQoL measurements, we analysed if their inclusion would have been proper or not. A total of 70 protocols (59 CTs and 11 phase IV observational studies) were analysed; 37 (52.8%) included PRO measures, and 3 protocols (4.3%) used them as a primary endpoint. Data analysis by therapeutic area showed that PRO measures were most commonly studied in the fields of endocrinology, neurology, digestive diseases, and cardiology. The average quality score for the trials was 2.8. The trials with more PRO inclusion in their end points had a significantly higher quality score. Only 13 (22%) clinical trials and 2 (18.2%) phase IV observational studies included economic variables. The emergence of economic variables in clinical trials and phase IV observational studies evaluated was low, however, more than half of the revised protocols have included PRO measures, reflecting the importance of these parameters in the assessment of the effectiveness of drug treatments, although its use is still not systematic. Copyright © 2011 SECA. Published by Elsevier Espana. All rights reserved.

  17. Noninvasive measurement of dynamic correlation functions

    NASA Astrophysics Data System (ADS)

    Uhrich, Philipp; Castrignano, Salvatore; Uys, Hermann; Kastner, Michael

    2017-08-01

    The measurement of dynamic correlation functions of quantum systems is complicated by measurement backaction. To facilitate such measurements we introduce a protocol, based on weak ancilla-system couplings, that is applicable to arbitrary (pseudo)spin systems and arbitrary equilibrium or nonequilibrium initial states. Different choices of the coupling operator give access to the real and imaginary parts of the dynamic correlation function. This protocol reduces disturbances due to the early-time measurements to a minimum, and we quantify the deviation of the measured correlation functions from the theoretical, unitarily evolved ones. Implementations of the protocol in trapped ions and other experimental platforms are discussed. For spin-1 /2 models and single-site observables we prove that measurement backaction can be avoided altogether, allowing for the use of ancilla-free protocols.

  18. A practical guideline for intracranial volume estimation in patients with Alzheimer's disease

    PubMed Central

    2015-01-01

    Background Intracranial volume (ICV) is an important normalization measure used in morphometric analyses to correct for head size in studies of Alzheimer Disease (AD). Inaccurate ICV estimation could introduce bias in the outcome. The current study provides a decision aid in defining protocols for ICV estimation in patients with Alzheimer disease in terms of sampling frequencies that can be optimally used on the volumetric MRI data, and the type of software most suitable for use in estimating the ICV measure. Methods Two groups of 22 subjects are considered, including adult controls (AC) and patients with Alzheimer Disease (AD). Reference measurements were calculated for each subject by manually tracing intracranial cavity by the means of visual inspection. The reliability of reference measurements were assured through intra- and inter- variation analyses. Three publicly well-known software packages (Freesurfer, FSL, and SPM) were examined in their ability to automatically estimate ICV across the groups. Results Analysis of the results supported the significant effect of estimation method, gender, cognitive condition of the subject and the interaction among method and cognitive condition factors in the measured ICV. Results on sub-sampling studies with a 95% confidence showed that in order to keep the accuracy of the interleaved slice sampling protocol above 99%, the sampling period cannot exceed 20 millimeters for AC and 15 millimeters for AD. Freesurfer showed promising estimates for both adult groups. However SPM showed more consistency in its ICV estimation over the different phases of the study. Conclusions This study emphasized the importance in selecting the appropriate protocol, the choice of the sampling period in the manual estimation of ICV and selection of suitable software for the automated estimation of ICV. The current study serves as an initial framework for establishing an appropriate protocol in both manual and automatic ICV estimations with different subject populations. PMID:25953026

  19. Breast dosimetry in clinical mammography

    NASA Astrophysics Data System (ADS)

    Benevides, Luis Alberto Do Rego

    The objective of this study was show that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. In the study, AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The protocol proposes the use of a fiber-optic coupled (FOCD) or Metal Oxide Semiconductor Field Effect Transistor (MOSFET) dosimeter to measure the entrance skin exposure at the time of the mammogram without interfering with diagnostic information of the mammogram. The study showed that FOCD had sensitivity with less than 7% energy dependence, linear in all tube current-time product stations, and was reproducible within 2%. FOCD was superior to MOSFET dosimeter in sensitivity, reusability, and reproducibility. The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. In addition, the study population anthropometric measurements enabled the development of analytical equations to calculate the whole breast area, estimate for the skin layer thickness and optimal location for automatic exposure control ionization chamber. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.

  20. Methodological development for 87Sr/86Sr measurement in olive oil and preliminary discussion of its use for geographical traceability of PDO Nîmes (France).

    PubMed

    Medini, Salim; Janin, Myriam; Verdoux, Patrick; Techer, Isabelle

    2015-03-15

    The lack of a geographical identification protocol for olive oils can lead to fraud and health risks. As some works call for Sr isotopes for the geographical identification of agri-food products, this study focus on the feasibility of extracting Sr from olive oils for isotopic measurements by TIMS. In fact, existing protocols for purification of Sr are unsuitable for lipid matrix. The defined protocol is applied to samples of PDO Nîmes olive oil. The accuracy of the extraction procedure is tested against isotopic standards. The values obtained are in conformity with NIST certified values. This consistency demonstrates that no modification of (87)Sr/(86)Sr ratio is brought about by this protocol. Consequently, the method is preliminary used on PDO Nîmes and Moroccan oils to evaluate the feasibility of a discriminant Sr signature on the two geographical products. This study provides promising results for the geographical discrimination and identification of PDO olive oils. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Effects of slow and accelerated rehabilitation protocols on range of motion after arthroscopic rotator cuff repair.

    PubMed

    Düzgün, İrem; Baltacı, Gül; Turgut, Elif; Atay, O Ahmet

    2014-01-01

    The aim of the study was to investigate the effects of the early initiation of passive and active range of motion exercises following arthroscopic rotator cuff repair. The study included 40 patients who underwent arthroscopic rotator cuff repair. Patients were quasi-randomly assigned into accelerated (ACCEL) protocol (n=19) and slow (SLOW) protocol (n=21) groups. Patients in both groups were treated with the same protocol. Active range of motion was begun at the 3rd week in the ACCEL group and the 6th week in the SLOW group. Range of motion was recorded at postoperative weeks 3, 5, 8, 12, and 24. While active range of motion for all measurements improved across weeks, there were no differences between groups, with the exception of active total elevation which was greater at all time point measurements in the ACCEL group (p<0.05). The early initiation of passive and gentle controlled active motion exercise following rotator cuff repairs does not appear to affect range of motion in the first 6 postoperative months.

  2. Miniaturization of the Clonogenic Assay Using Confluence Measurement

    PubMed Central

    Mayr, Christian; Beyreis, Marlena; Dobias, Heidemarie; Gaisberger, Martin; Pichler, Martin; Ritter, Markus; Jakab, Martin; Neureiter, Daniel; Kiesslich, Tobias

    2018-01-01

    The clonogenic assay is a widely used method to study the ability of cells to ‘infinitely’ produce progeny and is, therefore, used as a tool in tumor biology to measure tumor-initiating capacity and stem cell status. However, the standard protocol of using 6-well plates has several disadvantages. By miniaturizing the assay to a 96-well microplate format, as well as by utilizing the confluence detection function of a multimode reader, we here describe a new and modified protocol that allows comprehensive experimental setups and a non-endpoint, label-free semi-automatic analysis. Comparison of bright field images with confluence images demonstrated robust and reproducible detection of clones by the confluence detection function. Moreover, time-resolved non-endpoint confluence measurement of the same well showed that semi-automatic analysis was suitable for determining the mean size and colony number. By treating cells with an inhibitor of clonogenic growth (PTC-209), we show that our modified protocol is suitable for comprehensive (broad concentration range, addition of technical replicates) concentration- and time-resolved analysis of the effect of substances or treatments on clonogenic growth. In summary, this protocol represents a time- and cost-effective alternative to the commonly used 6-well protocol (with endpoint staining) and also provides additional information about the kinetics of clonogenic growth. PMID:29510509

  3. Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography.

    PubMed

    Olszewski, R; Frison, L; Wisniewski, M; Denis, J M; Vynckier, S; Cosnard, G; Zech, F; Reychler, H

    2013-01-01

    The purpose of this study is to compare the reproducibility of three-dimensional cephalometric landmarks on three-dimensional computed tomography (3D-CT) surface rendering using clinical protocols based on low-dose (35-mAs) spiral CT and cone-beam CT (I-CAT). The absorbed dose levels for radiosensitive organs in the maxillofacial region during exposure in both 3D-CT protocols were also assessed. The study population consisted of ten human dry skulls examined with low-dose CT and cone-beam CT. Two independent observers identified 24 cephalometric anatomic landmarks at 13 sites on the 3D-CT surface renderings using both protocols, with each observer repeating the identification 1 month later. A total of 1,920 imaging measurements were performed. Thermoluminescent dosimeters were placed at six sites around the thyroid gland, the submandibular glands, and the eyes in an Alderson phantom to measure the absorbed dose levels. When comparing low-dose CT and cone-beam CT protocols, the cone-beam CT protocol proved to be significantly more reproducible for four of the 13 anatomical sites. There was no significant difference between the protocols for the other nine anatomical sites. Both low-dose and cone-beam CT protocols were equivalent in dose absorption to the eyes and submandibular glands. However, thyroid glands were more irradiated with low-dose CT. Cone-beam CT was more reproducible and procured less irradiation to the thyroid gland than low-dose CT. Cone-beam CT should be preferred over low-dose CT for developing three-dimensional bony cephalometric analyses.

  4. The impact of protocol on nurses' role stress: a longitudinal perspective.

    PubMed

    Dodd-McCue, Diane; Tartaglia, Alexander; Veazey, Kenneth W; Streetman, Pamela S

    2005-04-01

    The study examined the impact of a protocol directed at increasing organ donation on the role stress and work attitudes of critical care nurses involved in potential organ donation cases. The research examined whether the protocol could positively affect nurses' perceptions of role stress, and if so, could the work environment improvements be sustained over time. The Family Communication Coordinator (FCC) protocol promotes effective communication during potential organ donation cases using a multidisciplinary team approach. Previous research found it associated with improved donation outcomes and with improved perceptions of role stress by critical care nurses. However, the previous study lacked methodological rigor necessary to determine causality and sustainability over time. The study used a quasi-experimental prospective longitudinal design. The sample included critical care nurses who had experience with potential organ donation cases with the protocol. Survey data were collected at 4 points over 2 years. Surveys used previously validated and reliable measures of role stress (role ambiguity, role conflict, role overload) and work attitudes (commitment, satisfaction). Interviews supplemented these data. The nurses' perceptions of role stress associated with potential organ donation cases dramatically dropped after the protocol was implemented. All measures of role stress, particularly role ambiguity and role conflict, showed statistically significant and sustained improvement. Nurses' professional, unit, and hospital commitment and satisfaction reflect an increasingly positive workplace. The results demonstrate that the FCC protocol positively influenced the workplace through its impact on role stress over the first 2 years following its implementation. The findings suggest that similar protocols may be appropriate in improving the critical care environment by reducing the stress and uncertainty of professionals involved in other end-of-life situations. However, the most striking implication relates to the reality of the workplace: meeting the goals of improved patient care outcomes and those of improving the healthcare work environment are not mutually exclusive and may be mutually essential.

  5. SeaWiFS technical report series. Volume 5: Ocean optics protocols for SeaWiFS validation

    NASA Technical Reports Server (NTRS)

    Mueller, James L.; Austin, Roswell W.; Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor)

    1992-01-01

    Protocols are presented for measuring optical properties, and other environmental variables, to validate the radiometric performance of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), and to develop and validate bio-optical algorithms for use with SeaWiFS data. The protocols are intended to establish foundations for a measurement strategy to verify the challenging SeaWiFS accuracy goals of 5 percent in water-leaving radiances and 35 percent in chlorophyll alpha concentration. The protocols first specify the variables which must be measured, and briefly review rationale. Subsequent chapters cover detailed protocols for instrument performance specifications, characterizing and calibration instruments, methods of making measurements in the field, and methods of data analysis. These protocols were developed at a workshop sponsored by the SeaWiFS Project Office (SPO) and held at the Naval Postgraduate School in Monterey, California (9-12 April, 1991). This report is the proceedings of that workshop, as interpreted and expanded by the authors and reviewed by workshop participants and other members of the bio-optical research community. The protocols are a first prescription to approach unprecedented measurement accuracies implied by the SeaWiFS goals, and research and development are needed to improve the state-of-the-art in specific areas. The protocols should be periodically revised to reflect technical advances during the SeaWiFS Project cycle.

  6. Management of persistent postconcussion symptoms in youth: a randomised control trial protocol

    PubMed Central

    Reed, Nick; Greenspoon, Dayna; Iverson, Grant L; DeMatteo, Carol; Fait, Philippe; Gauvin-Lepage, Jérôme; Hunt, Anne; Gagnon, Isabelle J

    2015-01-01

    Introduction Current management of concussion consists of early education, rest until symptom free, with gradual return to school and physical activity protocols. Although this management strategy is effective for most youth who sustain a concussion, it is not an appropriate strategy for youth with persistent postconcussion symptoms. Prolonged rest and periods of restricted activity may place youth at risk for secondary issues and contribute to the chronicity of postconcussion symptoms. The purpose of this study is to evaluate the efficacy of an active rehabilitation protocol for youth who are slow to recover from concussion. It is hypothesised that an active rehabilitation intervention can reduce persistent postconcussion symptoms, improve function and facilitate return to activity. This article describes the research protocol. Methods and analysis This is a randomised clinical trial with blinded outcome measurement. Participants will be recruited and randomly assigned to 1 of 2 treatment groups, an active rehabilitation intervention or a standard care education group. Both groups will receive standard care education. However, the active rehabilitation group will participate in an additional low-intensity exercise programme consisting of aerobic, coordination and visualisation exercises. Both the active rehabilitation and the standard care education interventions will be 6 weeks in duration. The primary outcome measure is postconcussion symptoms. Secondary outcome measures include functional recovery (cognitive, motor, psychosocial and emotional functioning) and return to activity. Outcome measures will be administered preintervention and postintervention. The primary outcome measure will also be repeated 2 weeks into the intervention period. Ethics and dissemination This study has been approved by the Holland Bloorview Kids Rehabilitation Hospital research ethics board (REB # 13-459). The findings from this study will be shared with the general public, sport associations, relevant brain injury organisations and healthcare professionals. Trial registration number NCT02257749. PMID:26231756

  7. Intensive group training protocol versus guideline physiotherapy for patients with chronic low back pain: a randomised controlled trial.

    PubMed

    van der Roer, Nicole; van Tulder, Maurits; Barendse, Johanna; Knol, Dirk; van Mechelen, Willem; de Vet, Henrica

    2008-09-01

    Intensive group training using principles of graded activity has been proven to be effective in occupational care for workers with chronic low back pain. Objective of the study was to compare the effects of an intensive group training protocol aimed at returning to normal daily activities and guideline physiotherapy for primary care patients with non-specific chronic low back pain. The study was designed as pragmatic randomised controlled trial with a setup of 105 primary care physiotherapists in 49 practices and 114 patients with non-specific low back pain of more than 12 weeks duration participated in the study. In the intensive group training protocol exercise therapy, back school and operant-conditioning behavioural principles are combined. Patients were treated during 10 individual sessions along 20 group sessions. Usual care consisted of physiotherapy according to the Dutch guidelines for Low Back Pain. Main outcome measures were functional disability (Roland Morris disability questionnaire), pain intensity, perceived recovery and sick leave because of low back pain assessed at baseline and after 6, 13, 26 and 52 weeks. Both an intention-to-treat analysis and a per-protocol analysis were performed. Multilevel analysis did not show significant differences between both treatment groups on any outcome measures during the complete follow-up period, with one exception. After 26 weeks the protocol group showed more reduction in pain intensity than the guideline group, but this difference was absent after 52 weeks. We finally conclude that an intensive group training protocol was not more effective than usual physiotherapy for chronic low back pain.

  8. Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study.

    PubMed

    Schindera, Sebastian T; Nelson, Rendon C; Toth, Thomas L; Nguyen, Giao T; Toncheva, Greta I; DeLong, David M; Yoshizumi, Terry T

    2008-02-01

    The purpose of this study was to evaluate in a phantom study the effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation. One or two 4-cm-thick circumferential layers of fat-equivalent material were added to the abdomen of an anthropomorphic phantom to simulate patients of three sizes: small (cross-sectional dimensions, 18 x 22 cm), average size (26 x 30 cm), and oversize (34 x 38 cm). Imaging was performed with a 64-MDCT scanner with combined z-axis and xy-axis tube current modulation according to two protocols: protocol A had a noise index of 12.5 H, and protocol B, 15.0 H. Radiation doses to three abdominal organs and the skin were assessed. Image noise also was measured. Despite increasing patient size, the image noise measured was similar for protocol A (range, 11.7-12.2 H) and protocol B (range, 13.9-14.8 H) (p > 0.05). With the two protocols, in comparison with the dose of the small patient, the abdominal organ doses of the average-sized patient and the oversized patient increased 161.5-190.6%and 426.9-528.1%, respectively (p < 0.001). The skin dose increased as much as 268.6% for the average-sized patient and 816.3% for the oversized patient compared with the small patient (p < 0.001). Oversized patients undergoing abdominal MDCT with tube current modulation receive significantly higher doses than do small patients. The noise index needs to be adjusted to the body habitus to ensure dose efficiency.

  9. Comparison between TG-51 and TG-21: Calibration of photon and electron beams in water using cylindrical chambers.

    PubMed

    Cho, S H; Lowenstein, J R; Balter, P A; Wells, N H; Hanson, W F

    2000-01-01

    A new calibration protocol, developed by the AAPM Task Group 51 (TG-51) to replace the TG-21 protocol, is based on an absorbed-dose to water standard and calibration factor (N(D,w)), while the TG-21 protocol is based on an exposure (or air-kerma) standard and calibration factor (N(x)). Because of differences between these standards and the two protocols, the results of clinical reference dosimetry based on TG-51 may be somewhat different from those based on TG-21. The Radiological Physics Center has conducted a systematic comparison between the two protocols, in which photon and electron beam outputs following both protocols were compared under identical conditions. Cylindrical chambers used in this study were selected from the list given in the TG-51 report, covering the majority of current manufacturers. Measured ratios between absorbed-dose and air-kerma calibration factors, derived from the standards traceable to the NIST, were compared with calculated values using the TG-21 protocol. The comparison suggests that there is roughly a 1% discrepancy between measured and calculated ratios. This discrepancy may provide a reasonable measure of possible changes between the absorbed-dose to water determined by TG-51 and that determined by TG-21 for photon beam calibrations. The typical change in a 6 MV photon beam calibration following the implementation of the TG-51 protocol was about 1%, regardless of the chamber used, and the change was somewhat smaller for an 18 MV photon beam. On the other hand, the results for 9 and 16 MeV electron beams show larger changes up to 2%, perhaps because of the updated electron stopping power data used for the TG-51 protocol, in addition to the inherent 1% discrepancy presented in the calibration factors. The results also indicate that the changes may be dependent on the electron energy.

  10. Different horse's paces during hippotherapy on spatio-temporal parameters of gait in children with bilateral spastic cerebral palsy: A feasibility study.

    PubMed

    Antunes, Fabiane Nunes; Pinho, Alexandre Severo do; Kleiner, Ana Francisca Rozin; Salazar, Ana Paula; Eltz, Giovana Duarte; de Oliveira Junior, Alcyr Alves; Cechetti, Fernanda; Galli, Manuela; Pagnussat, Aline Souza

    2016-12-01

    Hippotherapy is often carried out for the rehabilitation of children with Cerebral Palsy (CP), with the horse riding at a walking pace. This study aimed to explore the immediate effects of a hippotherapy protocol using a walk-trot pace on spatio-temporal gait parameters and muscle tone in children with Bilateral Spastic CP (BS-CP). Ten children diagnosed with BS-CP and 10 healthy aged-matched children (reference group) took part in this study. The children with BS-CP underwent two sessions of hippotherapy for one week of washout between them. Two protocols (lasting 30min) were applied on separate days: Protocol 1: the horse's pace was a walking pace; and Protocol 2: the horse's pace was a walk-trot pace. Children from the reference group were not subjected to treatment. A wireless inertial measurement unit measured gait spatio-temporal parameters before and after each session. The Modified Ashworth Scale was applied for muscle tone measurement of hip adductors. The participants underwent the gait assessment on a path with surface irregularities (ecological context). The comparisons between BS-CP and the reference group found differences in all spatio-temporal parameters, except for gait velocity. Within-group analysis of children with BS-CP showed that the swing phase did not change after the walk pace and after the walk-trot pace. The percentage of rolling phase and double support improved after the walk-trot. The spasticity of the hip adductors was significantly reduced as an immediate result of both protocols, but this decrease was more evident after the walk-trot. The walk-trot protocol is feasible and is able to induce an immediate effect that improves the gait spatio-temporal parameters and the hip adductors spasticity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Development of a Protocol for Automated Glucose Measurement Transmission Used in Clinical Decision Support Systems Based on the Continua Design Guidelines.

    PubMed

    Meyer, Markus; Donsa, Klaus; Truskaller, Thomas; Frohner, Matthias; Pohn, Birgit; Felfernig, Alexander; Sinner, Frank; Pieber, Thomas

    2018-01-01

    A fast and accurate data transmission from glucose meter to clinical decision support systems (CDSSs) is crucial for the management of type 2 diabetes mellitus since almost all therapeutic interventions are derived from glucose measurements. Aim was to develop a prototype of an automated glucose measurement transmission protocol based on the Continua Design Guidelines and to embed the protocol into a CDSS used by healthcare professionals. A literature and market research was performed to analyze the state-of-the-art and thereupon develop, integrate and validate an automated glucose measurement transmission protocol in an iterative process. Findings from literature and market research guided towards the development of a standardized glucose measurement transmission protocol using a middleware. The interface description to communicate with the glucose meter was illustrated and embedded into a CDSS. A prototype of an interoperable transmission of glucose measurements was developed and implemented in a CDSS presenting a promising way to reduce medication errors and improve user satisfaction.

  12. Chapter 23: Combined Heat and Power Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Simons, George; Barsun, Stephan

    The main focus of most evaluations is to determine the energy-savings impacts of the installed measure. This protocol defines a combined heat and power (CHP) measure as a system that sequentially generates both electrical energy and useful thermal energy from one fuel source at a host customer's facility or residence. This protocol is aimed primarily at regulators and administrators of ratepayer-funded CHP programs; however, project developers may find the protocol useful to understand how CHP projects are evaluated.

  13. Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu Jian; Kim, Minho; Peters, Jorg

    2009-12-15

    Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, themore » similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.« less

  14. Physician communication in the operating room.

    PubMed

    Kirschbaum, Kristin A; Rask, John P; Fortner, Sally A; Kulesher, Robert; Nelson, Michael T; Yen, Tony; Brennan, Matthew

    2015-01-01

    In this study, communication research was conducted with multidisciplinary groups of operating-room physicians. Theoretical frameworks from intercultural communication and rhetoric were used to (a) measure latent cultural communication variables and (b) conduct communication training with the physicians. A six-step protocol guided the research with teams of physicians from different surgical specialties: anesthesiologists, general surgeons, and obstetrician-gynecologists (n = 85). Latent cultural communication variables were measured by surveys administered to physicians before and after completion of the protocol. The centerpiece of the 2-hour research protocol was an instructional session that informed the surgical physicians about rhetorical choices that support participatory communication. Post-training results demonstrated scores increased on communication variables that contribute to collaborative communication and teamwork among the physicians. This study expands health communication research through application of combined intercultural and rhetorical frameworks, and establishes new ways communication theory can contribute to medical education.

  15. Effect of test exercises and mask donning on measured respirator fit.

    PubMed

    Crutchfield, C D; Fairbank, E O; Greenstein, S L

    1999-12-01

    Quantitative respirator fit test protocols are typically defined by a series of fit test exercises. A rationale for the protocols that have been developed is generally not available. There also is little information available that describes the effect or effectiveness of the fit test exercises currently specified in respiratory protection standards. This study was designed to assess the relative impact of fit test exercises and mask donning on respirator fit as measured by a controlled negative pressure and an ambient aerosol fit test system. Multiple donnings of two different sizes of identical respirator models by each of 14 test subjects showed that donning affects respirator fit to a greater degree than fit test exercises. Currently specified fit test protocols emphasize test exercises, and the determination of fit is based on a single mask donning. A rationale for a modified fit test protocol based on fewer, more targeted test exercises and multiple mask donnings is presented. The modified protocol identified inadequately fitting respirators as effectively as the currently specified Occupational Safety and Health Administration (OSHA) quantitative fit test protocol. The controlled negative pressure system measured significantly (p < 0.0001) more respirator leakage than the ambient aerosol fit test system. The bend over fit test exercise was found to be predictive of poor respirator fit by both fit test systems. For the better fitting respirators, only the talking exercise generated aerosol fit factors that were significantly lower (p < 0.0001) than corresponding donning fit factors.

  16. SITE-SPECIFIC PROTOCOL FOR MEASURING SOIL RADON POTENTIALS FOR FLORIDA HOUSES

    EPA Science Inventory

    The report describes a protocol for site-specific measurement of radon potentials for Florida houses that is consistent with existing residential radon protection maps. The protocol gives further guidance on the possible need for radon-protective house construction features. In a...

  17. 'Be active, eat right', evaluation of an overweight prevention protocol among 5-year-old children: design of a cluster randomised controlled trial.

    PubMed

    Veldhuis, Lydian; Struijk, Mirjam K; Kroeze, Willemieke; Oenema, Anke; Renders, Carry M; Bulk-Bunschoten, Anneke Mw; Hirasing, Remy A; Raat, Hein

    2009-06-08

    The prevalence of overweight and obesity in children has at least doubled in the past 25 years with a major impact on health. In 2005 a prevention protocol was developed applicable within Youth Health Care. This study aims to assess the effects of this protocol on prevalence of overweight and health behaviour among children. A cluster randomised controlled trial is conducted among 5-year-old children included by 44 Youth Health Care teams randomised within 9 Municipal Health Services. The teams are randomly allocated to the intervention or control group. The teams measure the weight and height of all children. When a child in the intervention group is detected with overweight according to the international age and gender specific cut-off points of BMI, the prevention protocol is applied. According to this protocol parents of overweight children are invited for up to three counselling sessions during which they receive personal advice about a healthy lifestyle, and are motivated for and assisted in behavioural change.The primary outcome measures are Body Mass Index and waist circumference of the children. Parents will complete questionnaires to assess secondary outcome measures: levels of overweight inducing/reducing behaviours (i.e. being physically active, having breakfast, drinking sweet beverages and watching television/playing computer games), parenting styles, parenting practices, and attitudes of parents regarding these behaviours, health-related quality of life of the children, and possible negative side effects of the prevention protocol. Data will be collected at baseline (when the children are aged 5 years), and after 12 and 24 months of follow-up. Additionally, a process and a cost-effectiveness evaluation will be conducted. In this study called 'Be active, eat right' we evaluate an overweight prevention protocol for use in the setting of Youth Health Care. It is hypothesized that the use of this protocol will result in a healthier lifestyle of the children and an improved BMI and waist circumference. Current Controlled Trials ISRCTN04965410.

  18. FISH-Flow, a protocol for the concurrent detection of mRNA and protein in single cells using fluorescence in situ hybridization and flow cytometry

    PubMed Central

    Arrigucci, Riccardo; Bushkin, Yuri; Radford, Felix; Lakehal, Karim; Vir, Pooja; Pine, Richard; Martin, December; Sugarman, Jeffrey; Zhao, Yanlin; Yap, George S; Lardizabal, Alfred A; Tyagi, Sanjay; Gennaro, Maria Laura

    2017-01-01

    We describe a flow-cytometry-based protocol for intracellular mRNA measurements in nonadherent mammalian cells using fluorescence in situ hybridization (FISH) probes. The method, which we call FISH-Flow, allows for high-throughput multiparametric measurements of gene expression, a task that was not feasible with earlier, microscopy-based approaches. The FISH-Flow protocol involves cell fixation, permeabilization and hybridization with a set of fluorescently labeled oligonucleotide probes. In this protocol, surface and intracellular protein markers can also be stained with fluorescently labeled antibodies for simultaneous protein and mRNA measurement. Moreover, a semiautomated, single-tube version of the protocol can be performed with a commercially available cell-wash device that reduces cell loss, operator time and interoperator variability. It takes ~30 h to perform this protocol. An example of FISH-Flow measurements of cytokine mRNA induction by ex vivo stimulation of primed T cells with specific antigens is described. PMID:28518171

  19. The measure of treatment agreement between portable and laboratory blood gas measurements in guiding protocol-driven ventilator management.

    PubMed

    Thomas, Frank O; Hoffman, Terri L; Handrahan, Diana L; Crapo, Robert O; Snow, Greg

    2009-08-01

    Portable blood gas analyzer and monitor devices are increasingly being used to direct ventilator therapy. The purpose of this study was to evaluate the "measure of treatment agreement" between portable and laboratory blood gas measurements used in guiding protocol-driven ventilator management. Using National Institutes of Health Acute Respiratory Distress Syndrome network ventilator management guidelines to manage patient care, measurements taken from the Nonin 8500 M pulse oximeter (SpO2), the Novametrix-610 end-tidal CO2 (ETCO2) detector, and the i-STAT 1 (SaO2, PO2, pH, PCO2) were compared with the recommended treatment from paired laboratory ABL-725 (SaCO2, PO2, pH, PCO2) measurements. Four hundred forty-six intubated adult intensive care unit patients were studied prospectively. Except for the ETCO2 (R2 = 0.460), correlation coefficients between portable and laboratory measurements were high (R2 > or = 0.755). Testing for equivalence, the Nonin-SpO2, iSTAT-PO2, iSTAT-pH, and iSTAT-PCO2 were deemed "equivalent" surrogates to paired ABL measurements. Testing for the limits of agreement found only the iSTAT-PCO2 to be an acceptable surrogate measurement. The measure of treatment agreement between the portable and paired laboratory blood gas measurements were Nonin-SpO2 (68%), iSTAT-SaO2 (73%), iSTAT-PO2 (97%), iSTAT-pH (88%), iSTAT-PCO2 (95%), and Novametrix-ETCO2 (60%). Only the iSTAT-PO2 and the iSTAT-PCO2 achieved the > or =95% treatment agreement threshold to be considered as acceptable surrogates to laboratory measurements. : The iSTAT-PO2 and -PCO2 were portable device measurements acceptable as surrogates to standard clinical laboratory blood gas measurements in guiding protocol-directed ventilator management. The "measure of treatment agreement," based on standardized decisions and measurement thresholds of a protocol, provides a simple method for assessing clinical validity of surrogate measurements.

  20. Presentation of Aural Stimuli to Newborns and Premature Infants: An Audiological Perspective.

    PubMed

    Cassidy

    1999-01-01

    The purpose of this study was twofold: (a) to examine extant research in the field of music with premature and full term infants in order to identify protocols being used in the presentation of musical stimuli to neonates and (b) to use knowledge gleaned from audiology as a basis for suggesting a standardized protocol for use of musical stimuli with infants. Articles considered appropriate for inclusion in the analysis met the following criteria: (a) presented data for the effects of music on a dependent measure, (b) had subjects who were identified as either premature or term newborns receiving treatment after birth and prior to discharge from the hospital, and (c) used music for some or all of the aural stimuli. Articles (N = 20) were categorized by demographic information, types of aural stimuli, independent variables, dependent measures, and protocol used to present the musical stimuli. Of primary importance to this study was the protocol used in each study to present musical stimuli. Data regarding total duration of stimuli per day, longest duration of stimuli per day, method of stimuli presentation, placement of speakers, decibel level of stimuli, and where;he decibel level was measured reveal that there is no standard protocol being followed with regard to the presentation of aural stimuli. Recommendations include future research on (a) determining a minimum gestational age where music therapy may be appropriate, (b) determining the frequency spectrum perceived by a premature infant, (c) determining the decibel levels reaching the ear drum and assessing appropriate levels for minimum stimulation with maximum results, and (d) carefully considering the method of stimulus presentation as it will have an impact on the decibel level reaching the ear drum of these infants.

  1. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drzymala, R. E., E-mail: drzymala@wustl.edu; Alvarez, P. E.; Bednarz, G.

    2015-11-15

    Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods:more » Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG-21 + ABS dose-rate were 0.999 ± 0.009 (TG-21), 0.991 ± 0.013 (TG-51), 1.000 ± 0.009 (IAEA), and 1.009 ± 0.012 (in-air). There were no statistically significant differences (i.e., p > 0.05) between the two ionization chambers for the TG-21 protocol applied to all dosimetry phantoms. The mean results using the TG-51 protocol were notably lower than those for the other dosimetry protocols, with a standard deviation 2–3 times larger. The in-air protocol was not statistically different from TG-21 for the A16 chamber in the liquid water or ABS phantoms (p = 0.300 and p = 0.135) but was statistically different from TG-21 for the PTW chamber in all phantoms (p = 0.006 for Solid Water, 0.014 for liquid water, and 0.020 for ABS). Results of IAEA formalism were statistically different from TG-21 results only for the combination of the A16 chamber with the liquid water phantom (p = 0.017). In the latter case, dose-rates measured with the two protocols differed by only 0.4%. For other phantom-ionization-chamber combinations, the new IAEA formalism was not statistically different from TG-21. Conclusions: Although further investigation is needed to validate the new protocols for other ionization chambers, these results can serve as a reference to quantitatively compare different calibration protocols and ionization chambers if a particular method is chosen by a professional society to serve as a standardized calibration protocol.« less

  2. Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Gowans, Dakers; Telarico, Chad

    The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

  3. Quantum private comparison protocol based on the entanglement swapping between χ ^+ state and W-Class state

    NASA Astrophysics Data System (ADS)

    Xu, Ling; Zhao, Zhiwen

    2017-12-01

    Quantum private comparison (QPC) protocol, including Alice, Bob and the third party Charlie, aims at comparing Alice and Bob's secret inputs correctly without leaking them. Firstly, χ ^+ state and W-Class state are used to conduct the entanglement swapping in this protocol. Either the basis {|φ ^± > ,|ψ ^± >} or the basis {|χ ^± > ,|ω ^± > } is chosen by Alice and Bob based on the predetermined value to measure the particle pairs. And three bits of secret inputs can be compared in this protocol in every comparison time, while most of previous QPC protocols can only compare one or two bits. The qubit efficiency of this protocol is 60% more than others, which are 50% at most. Secondly, if the eavesdropper intends to obtain the secret inputs, it is important and primary to get the measurement results of particle pairs. In this protocol, even if the eavesdropper gets the accurate particle pairs, he cannot get the right measurement results without the right basis. Finally, this protocol is analyzed to be able to defend the secret inputs against various kinds of attack.

  4. TEST CELL STUDIES OF RADON ENTRY

    EPA Science Inventory

    The report gives results of a study to contrast the effectiveness of slab-in-stem wall (SSW) with floating slab (FS) construction practices, to measure radon transport and entry for model testing, to develop protocols relevant to depressurized radon measurements, and to determine...

  5. Assessment tools for the measurement of the self-efficacy of drug users: protocol for a systematic review.

    PubMed

    Vasconcelos, Selene Cordeiro; Frazão, Iracema da Silva; Sougey, Everton Botelho; Souza, Sandra Lopes de; Silva, Tatiana de Paula Santana da; Lima, Murilo Duarte da Costa

    2018-03-14

    The abuse of alcohol and other drugs is a worldwide problem, the treatment of which poses a challenge to healthcare workers. This study presents a proposal for a systematic review to analyse the psychometric properties of assessment tools developed to measure the self-efficacy of drug users with regard to resisting the urge to take drugs in high-risk situations. The guiding question was based on PICOS (Population Intervention Comparator Outcome Setting), and the report of the methods of review protocol was written in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols (PRISMA-P). Searches will be performed in the PsycINFO, Cochrane, Pubmed, Web of Science, SCOPUS and CINAHL databases, followed by the use of the 'snowball' strategy. The inclusion criteria for the articles will be (1) assessment tool validation studies; (2) assessment tools developed to measure self-efficacy; (3) quantitative measures; (4) measures designed for use on adults; (5) data from self-reports of the participants; (6) studies involving a description of psychometric properties of the measures; and (7) studies that explain how the level of self-efficacy is scored. The search, selection and analysis will be performed by two independent reviewers. In cases of a divergence of opinion, a third reviewer will be consulted. The COSMIN checklist will be used for the appraisal of the methodological quality of the assessment tools and the certainty of the evidence in the articles (risk of bias) will be analysed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. This protocol does not require ethical approval. However, this protocol is part of the thesis entitled Drug-Taking Confidence Questionnaire for use in Brazil, presented for obtaining a doctorate in neuropsychiatry and behavioural sciences from the Federal University of Pernambuco, and has received approval from the human research ethics committee of the Federal University of Pernambuco (reference number: 1.179.162).The results will be disseminated to clinicians and researchers through peer-reviewed publications and conferences. CRD42017068555. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Differences in Writers' Initial Task Representations. Technical Report No. 35.

    ERIC Educational Resources Information Center

    Carey, Linda; And Others

    An exploratory study investigated how writers represent their task to themselves before beginning to write. Using data from verbal protocols, the initial plans of 12 writers (5 experts and 7 student writers) who were working on an expository writing task were examined. The protocols were coded for types of planning. Independent measures of the…

  7. Effect of an Incontinence Training Program on Nursing Home Staff's Knowledge, Attitudes, and Behavior.

    ERIC Educational Resources Information Center

    Campbell, Emily B; And Others

    1991-01-01

    Nursing staff (n=166) in four nursing homes participated in quasi-experimental study to measure knowledge and attitudes about urinary incontinence and compliance with toileting protocols. Intervention group (n=96) showed slight increase in knowledge; their attitudes remained positive over four testing times. Compliance with protocol was only 72…

  8. Enhancing QKD security with weak measurements

    NASA Astrophysics Data System (ADS)

    Farinholt, Jacob M.; Troupe, James E.

    2016-10-01

    Publisher's Note: This paper, originally published on 10/24/2016, was replaced with a corrected/revised version on 11/8/2016. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance. In the late 1980s, Aharonov and colleagues developed the notion of a weak measurement of a quantum observable that does not appreciably disturb the system.1, 2 The measurement results are conditioned on both the pre-selected and post-selected state of the quantum system. While any one measurement reveals very little information, by making the same measurement on a large ensemble of identically prepared pre- and post-selected (PPS) states and averaging the results, one may obtain what is known as the weak value of the observable with respect to that PPS ensemble. Recently, weak measurements have been proposed as a method of assessing the security of QKD in the well-known BB84 protocol.3 This weak value augmented QKD protocol (WV-QKD) works by additionally requiring the receiver, Bob, to make a weak measurement of a particular observable prior to his strong measurement. For the subset of measurement results in which Alice and Bob's measurement bases do not agree, the weak measurement results can be used to detect any attempt by an eavesdropper, Eve, to correlate her measurement results with Bob's. Furthermore, the well-known detector blinding attacks, which are known to perfectly correlate Eve's results with Bob's without being caught by conventional BB84 implementations, actually make the eavesdropper more visible in the new WV-QKD protocol. In this paper, we will introduce the WV-QKD protocol and discuss its generalization to the 6-state single qubit protocol. We will discuss the types of weak measurements that are optimal for this protocol, and compare the predicted performance of the 6- and 4-state WV-QKD protocols.

  9. Effect of two complex training protocols of back squats in blood indicators of muscular damage in military athletes

    PubMed Central

    Ojeda, Álvaro Huerta; Ríos, Luis Chirosa; Barrilao, Rafael Guisado; Ríos, Ignacio Chirosa; Serrano, Pablo Cáceres

    2016-01-01

    [Purpose] The aim of this study was to determine the variations in the blood muscular damage indicators post application of two complex training programs for back squats. [Subjects and Methods] Seven military athletes were the subjects of this study. The study had a quasi-experimental cross-over intra-subject design. Two complex training protocols were applied, and the variables to be measured were cortisol, metabolic creatine kinase, and total creatine kinase. For the statistical analysis, Student’s t-test was used. [Results] Twenty-four hours post effort, a significant decrease in cortisol level was shown for both protocols; however, the metabolic creatine kinase and total creatine kinase levels showed a significant increase. [Conclusion] Both protocols lowered the indicator of main muscular damage in the blood supply (cortisol). This proved that the work weight did not generate significant muscular damage in the 24-hour post-exercise period. PMID:27313356

  10. Effect of two complex training protocols of back squats in blood indicators of muscular damage in military athletes.

    PubMed

    Ojeda, Álvaro Huerta; Ríos, Luis Chirosa; Barrilao, Rafael Guisado; Ríos, Ignacio Chirosa; Serrano, Pablo Cáceres

    2016-05-01

    [Purpose] The aim of this study was to determine the variations in the blood muscular damage indicators post application of two complex training programs for back squats. [Subjects and Methods] Seven military athletes were the subjects of this study. The study had a quasi-experimental cross-over intra-subject design. Two complex training protocols were applied, and the variables to be measured were cortisol, metabolic creatine kinase, and total creatine kinase. For the statistical analysis, Student's t-test was used. [Results] Twenty-four hours post effort, a significant decrease in cortisol level was shown for both protocols; however, the metabolic creatine kinase and total creatine kinase levels showed a significant increase. [Conclusion] Both protocols lowered the indicator of main muscular damage in the blood supply (cortisol). This proved that the work weight did not generate significant muscular damage in the 24-hour post-exercise period.

  11. Development of a method for measuring femoral torsion using real-time ultrasound.

    PubMed

    Hafiz, Eliza; Hiller, Claire E; Nicholson, Leslie L; Nightingale, E Jean; Clarke, Jillian L; Grimaldi, Alison; Eisenhuth, John P; Refshauge, Kathryn M

    2014-07-01

    Excessive femoral torsion has been associated with various musculoskeletal and neurological problems. To explore this relationship, it is essential to be able to measure femoral torsion in the clinic accurately. Computerized tomography (CT) and magnetic resonance imaging (MRI) are thought to provide the most accurate measurements but CT involves significant radiation exposure and MRI is expensive. The aim of this study was to design a method for measuring femoral torsion in the clinic, and to determine the reliability of this method. Details of design process, including construction of a jig, the protocol developed and the reliability of the method are presented. The protocol developed used ultrasound to image a ridge on the greater trochanter, and a customized jig placed on the femoral condyles as reference points. An inclinometer attached to the customized jig allowed quantification of the degree of femoral torsion. Measurements taken with this protocol had excellent intra- and inter-rater reliability (ICC2,1 = 0.98 and 0.97, respectively). This method of measuring femoral torsion also permitted measurement of femoral torsion with a high degree of accuracy. This method is applicable to the research setting and, with minor adjustments, will be applicable to the clinical setting.

  12. Comparison of Bruce treadmill exercise test protocols: is ramped Bruce equal or superior to standard bruce in producing clinically valid studies for patients presenting for evaluation of cardiac ischemia or arrhythmia with body mass index equal to or greater than 30?

    PubMed

    Bires, Angela Macci; Lawson, Dori; Wasser, Thomas E; Raber-Baer, Donna

    2013-12-01

    Clinically valid cardiac evaluation via treadmill stress testing requires patients to achieve specific target heart rates and to successfully complete the cardiac examination. A comparison of the standard Bruce protocol and the ramped Bruce protocol was performed using data collected over a 1-y period from a targeted patient population with a body mass index (BMI) equal to or greater than 30 to determine which treadmill protocol provided more successful examination results. The functional capacity, metabolic equivalent units achieved, pressure rate product, and total time on the treadmill as measured for the obese patients were clinically valid and comparable to normal-weight and overweight patients (P < 0.001). Data gathered from each protocol demonstrated that the usage of the ramped Bruce protocol achieved more consistent results in comparison across all BMI groups in achieving 80%-85% of their age-predicted maximum heart rate. This study did not adequately establish that the ramped Bruce protocol was superior to the standard Bruce protocol for the examination of patients with a BMI equal to or greater than 30.

  13. Comparison of jump-landing protocols with Biodex Balance System as measures of dynamic postural stability in athletes.

    PubMed

    Krkeljas, Zarko

    2017-07-21

    The objective of the study was to determine whether a relationship exists between the two common methods for assessing postural stability in athletes: the time-to-stabilisation (TTS) via force-plate and the Biodex Balance System (BBS). The conditions under which these measurements assess dynamic postural control may not provide sufficient feedback to practitioners. Fourty-four amateur soccer players with no history of musculoskeletal disorders volunteered for the study. Pearson correlation was used to compare the anterior-posterior (AP), medio-lateral (ML), and the overall stability indexes measured by BBS, with the corresponding parameters of TTS assessed via force plate. There was no significant correlation between any parameters of dynamic stability measured by force-plate and the stability indexes. However, there was a significant correlation between the resulting vectors and the AP component of TTS for each jump protocol. Furthermore, forward drop landing exhibited shortest TTS in AP direction, while lateral drop landing resulted in longer ML TTS relative to both forward jumps (p < 0.001). These results demonstrate that the TTS and BBS stability indexes should be used as distinct measures of dynamic postural stability. TTS protocols may be modified to target a specific training conditions or athletic population.

  14. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  15. Effects of the TCARE® intervention on caregiver burden and depressive symptoms: preliminary findings from a randomized controlled study.

    PubMed

    Montgomery, Rhonda J V; Kwak, Jung; Kosloski, Karl; O'Connell Valuch, Katharine

    2011-09-01

    We examined the effects of a manualized care management protocol specifically designed for care managers working with caregivers, the Tailored Caregiver Assessment and Referral® (TCARE®) protocol, on caregiver identity discrepancy, burden, and depressive symptoms. Preliminary data from a longitudinal, randomized, controlled intervention study with 266 family caregivers served by 52 care managers in 4 states were analyzed using repeated measures random effects regression procedures. Caregivers in the intervention and control groups were repeatedly assessed for up to 9 months on caregiver identity discrepancy, 3 areas of caregiving burden-objective, relationship, and stress burdens; depression; and intention for nursing home placement. We found significant group by time interaction effects for caregiver identity discrepancy, relationship burden, stress burden, depression, and intention for nursing home placement. Caregivers in the intervention group experienced significant improvement on these measures, whereas caregivers in the control group worsened on these measures over time. The preliminary findings provide strong support for effectiveness of the TCARE® protocol on improving caregiver well-being and mental health outcomes.

  16. Effects of the TCARE® Intervention on Caregiver Burden and Depressive Symptoms: Preliminary Findings From a Randomized Controlled Study

    PubMed Central

    Kwak, Jung; Kosloski, Karl; O’Connell Valuch, Katharine

    2011-01-01

    Objectives. We examined the effects of a manualized care management protocol specifically designed for care managers working with caregivers, the Tailored Caregiver Assessment and Referral® (TCARE®) protocol, on caregiver identity discrepancy, burden, and depressive symptoms. Methods. Preliminary data from a longitudinal, randomized, controlled intervention study with 266 family caregivers served by 52 care managers in 4 states were analyzed using repeated measures random effects regression procedures. Caregivers in the intervention and control groups were repeatedly assessed for up to 9 months on caregiver identity discrepancy, 3 areas of caregiving burden—objective, relationship, and stress burdens; depression; and intention for nursing home placement. Results. We found significant group by time interaction effects for caregiver identity discrepancy, relationship burden, stress burden, depression, and intention for nursing home placement. Caregivers in the intervention group experienced significant improvement on these measures, whereas caregivers in the control group worsened on these measures over time. Discussion. The preliminary findings provide strong support for effectiveness of the TCARE® protocol on improving caregiver well-being and mental health outcomes. PMID:21840840

  17. Evaluation of a continuous-rotation, high-speed scanning protocol for micro-computed tomography.

    PubMed

    Kerl, Hans Ulrich; Isaza, Cristina T; Boll, Hanne; Schambach, Sebastian J; Nolte, Ingo S; Groden, Christoph; Brockmann, Marc A

    2011-01-01

    Micro-computed tomography is used frequently in preclinical in vivo research. Limiting factors are radiation dose and long scan times. The purpose of the study was to compare a standard step-and-shoot to a continuous-rotation, high-speed scanning protocol. Micro-computed tomography of a lead grid phantom and a rat femur was performed using a step-and-shoot and a continuous-rotation protocol. Detail discriminability and image quality were assessed by 3 radiologists. The signal-to-noise ratio and the modulation transfer function were calculated, and volumetric analyses of the femur were performed. The radiation dose of the scan protocols was measured using thermoluminescence dosimeters. The 40-second continuous-rotation protocol allowed a detail discriminability comparable to the step-and-shoot protocol at significantly lower radiation doses. No marked differences in volumetric or qualitative analyses were observed. Continuous-rotation micro-computed tomography significantly reduces scanning time and radiation dose without relevantly reducing image quality compared with a normal step-and-shoot protocol.

  18. How to Study Biofilms after Microbial Colonization of Materials Used in Orthopaedic Implants.

    PubMed

    Drago, Lorenzo; Agrappi, Serse; Bortolin, Monica; Toscano, Marco; Romanò, Carlo Luca; De Vecchi, Elena

    2016-02-26

    Over the years, various techniques have been proposed for the quantitative evaluation of microbial biofilms. Spectrophotometry after crystal violet staining is a widespread method for biofilm evaluation, but several data indicate that it does not guarantee a good specificity, although it is rather easy to use and cost saving. Confocal laser microscopy is one of the most sensitive and specific tools to study biofilms, and it is largely used for research. However, in some cases, no quantitative measurement of the matrix thickness or of the amount of embedded microorganisms has been performed, due to limitation in availability of dedicated software. For this reason, we have developed a protocol to evaluate the microbial biofilm formed on sandblasted titanium used for orthopaedic implants, that allows measurement of biomass volume and the amount of included cells. Results indicate good reproducibility in terms of measurement of biomass and microbial cells. Moreover, this protocol has proved to be applicable for evaluation of the efficacy of different anti-biofilm treatments used in the orthopaedic setting. Summing up, the protocol here described is a valid and inexpensive method for the study of microbial biofilm on prosthetic implant materials.

  19. [Air pollutant exposure during pregnancy and fetal and early childhood development. Research protocol of the INMA (Childhood and Environment Project)].

    PubMed

    Esplugues, Ana; Fernández-Patier, Rosalía; Aguilera, Inma; Iñíguez, Carmen; García Dos Santos, Saúl; Aguirre Alfaro, Amelia; Lacasaña, Marina; Estarlich, Marisa; Grimalt, Joan O; Fernández, Marieta; Rebagliato, Marisa; Sala, María; Tardón, Adonina; Torrent, Maties; Martínez, María Dolores; Ribas-Fitó, Núria; Sunyer, Jordi; Ballester, Ferran

    2007-01-01

    The INMA (INfancia y Medio Ambiente [Spanish for Environment and Childhood]) project is a cooperative research network. This project aims to study the effects of environment and diet on fetal and early childhood development. This article aims to present the air pollutant exposure protocol during pregnancy and fetal and early childhood development of the INMA project. The information to assess air pollutant exposure during pregnancy is based on outdoor measurement of air pollutants (nitrogen dioxide [NO2], volatile organic compounds [VOC], ozone, particulate matter [PM10, PM2,5 ] and of their composition [polycyclic aromatic hydrocarbons]); measurement of indoor and personal exposure (VOC and NO2); urinary measurement of a biological marker of hydrocarbon exposure (1-hydroxypyrene); and data gathered by questionnaires and geographic information systems. These data allow individual air pollutant exposure indexes to be developed, which can then be used to analyze the possible effects of exposure on fetal development and child health. This protocol and the type of study allow an approximation to individual air pollutant exposure to be obtained. Finally, the large number of participants (N = 4,000), as well as their geographic and social diversity, increases the study's potential.

  20. The Benefit of Remote Microphones Using Four Wireless Protocols.

    PubMed

    Rodemerk, Krishna S; Galster, Jason A

    2015-09-01

    Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearing aids. As a result, commercial remote microphone systems use a variety of different protocols for wireless audio transmission. It is not known how these systems compare, with regard to adult speech recognition in noise. The primary goal of this investigation was to determine the speech recognition benefits of four different commercially available remote microphone systems, each with a different wireless audio transmission protocol. A repeated-measures design was used in this study. Sixteen adults, ages 52 to 81 yr, with mild to severe sensorineural hearing loss participated in this study. Participants were fit with three different sets of bilateral hearing aids and four commercially available remote microphone systems (FM, 900 MHz, 2.4 GHz, and Bluetooth(®) paired with near-field magnetic induction). Speech recognition scores were measured by an adaptive version of the Hearing in Noise Test (HINT). The participants were seated both 6 and 12' away from the talker loudspeaker. Participants repeated HINT sentences with and without hearing aids and with four commercially available remote microphone systems in both seated positions with and without contributions from the hearing aid or environmental microphone (24 total conditions). The HINT SNR-50, or the signal-to-noise ratio required for correct repetition of 50% of the sentences, was recorded for all conditions. A one-way repeated measures analysis of variance was used to determine statistical significance of microphone condition. The results of this study revealed that use of the remote microphone systems statistically improved speech recognition in noise relative to unaided and hearing aid-only conditions across all four wireless transmission protocols at 6 and 12' away from the talker. Participants showed a significant improvement in speech recognition in noise when comparing four remote microphone systems with different wireless transmission methods to hearing aids alone. American Academy of Audiology.

  1. Air pollution effects on food quality. 2nd annual progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pell, E.J.

    1979-02-01

    Progress is reported in studies to determine the effect of acute, toxic exposures of ozone to alfalfa, potato, and soybean plants. The objective has been to correlate the foliar response with alterations in quality of the edible portion of the plant viz. the leaf, tuber and seed of alfalfa, potato and soybean, respectively. In 1977 we (1) modified our fumigation facilities, (2) developed protocol for studies with alfalfa and potato, and (3) conducted studies on flavonoid status of alfalfa and a series of parameters of potato tubers. In 1978 we (1) conducted more indepth studies with alfalfa, (2) repeated themore » potato study, (3) began to develop protocol for measuring additional parameters of alfalfa and potato quality, and (4) developed protocol for cultivating and exposing soybean plants.« less

  2. Protocol and standard operating procedures for common use in a worldwide multicenter study on reference values.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George

    2013-05-01

    The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.

  3. Robust QKD-based private database queries based on alternative sequences of single-qubit measurements

    NASA Astrophysics Data System (ADS)

    Yang, YuGuang; Liu, ZhiChao; Chen, XiuBo; Zhou, YiHua; Shi, WeiMin

    2017-12-01

    Quantum channel noise may cause the user to obtain a wrong answer and thus misunderstand the database holder for existing QKD-based quantum private query (QPQ) protocols. In addition, an outside attacker may conceal his attack by exploiting the channel noise. We propose a new, robust QPQ protocol based on four-qubit decoherence-free (DF) states. In contrast to existing QPQ protocols against channel noise, only an alternative fixed sequence of single-qubit measurements is needed by the user (Alice) to measure the received DF states. This property makes it easy to implement the proposed protocol by exploiting current technologies. Moreover, to retain the advantage of flexible database queries, we reconstruct Alice's measurement operators so that Alice needs only conditioned sequences of single-qubit measurements.

  4. High throughput exploration of process-property linkages in Al-6061 using instrumented spherical microindentation and microstructurally graded samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, Jordan S.; Khosravani, Ali; Castillo, Andrew

    Recent spherical nanoindentation protocols have proven robust at capturing the local elastic-plastic response of polycrystalline metal samples at length scales much smaller than the grain size. In this work, we extend these protocols to length scales that include multiple grains to recover microindentation stress-strain curves. These new protocols are first established in this paper and then demonstrated for Al-6061 by comparing the measured indentation stress-strain curves with the corresponding measurements from uniaxial tension tests. More specifically, the scaling factors between the uniaxial yield strength and the indentation yield strength was determined to be about 1.9, which is significantly lower thanmore » the value of 2.8 used commonly in literature. Furthermore, the reasons for this difference are discussed. Second, the benefits of these new protocols in facilitating high throughput exploration of process-property relationships are demonstrated through a simple case study.« less

  5. High throughput exploration of process-property linkages in Al-6061 using instrumented spherical microindentation and microstructurally graded samples

    DOE PAGES

    Weaver, Jordan S.; Khosravani, Ali; Castillo, Andrew; ...

    2016-06-14

    Recent spherical nanoindentation protocols have proven robust at capturing the local elastic-plastic response of polycrystalline metal samples at length scales much smaller than the grain size. In this work, we extend these protocols to length scales that include multiple grains to recover microindentation stress-strain curves. These new protocols are first established in this paper and then demonstrated for Al-6061 by comparing the measured indentation stress-strain curves with the corresponding measurements from uniaxial tension tests. More specifically, the scaling factors between the uniaxial yield strength and the indentation yield strength was determined to be about 1.9, which is significantly lower thanmore » the value of 2.8 used commonly in literature. Furthermore, the reasons for this difference are discussed. Second, the benefits of these new protocols in facilitating high throughput exploration of process-property relationships are demonstrated through a simple case study.« less

  6. Differential Sarcomere and Electrophysiological Maturation of Human iPSC-Derived Cardiac Myocytes in Monolayer vs. Aggregation-Based Differentiation Protocols

    PubMed Central

    Jeziorowska, Dorota; Fontaine, Vincent; Jouve, Charlène; Villard, Eric; Dussaud, Sébastien; Akbar, David; Letang, Valérie; Cervello, Pauline; Itier, Jean-Michiel; Pruniaux, Marie-Pierre; Hulot, Jean-Sébastien

    2017-01-01

    Human induced pluripotent stem cells (iPSCs) represent a powerful human model to study cardiac disease in vitro, notably channelopathies and sarcomeric cardiomyopathies. Different protocols for cardiac differentiation of iPSCs have been proposed either based on embroid body formation (3D) or, more recently, on monolayer culture (2D). We performed a direct comparison of the characteristics of the derived cardiomyocytes (iPSC-CMs) on day 27 ± 2 of differentiation between 3D and 2D differentiation protocols with two different Wnt-inhibitors were compared: IWR1 (inhibitor of Wnt response) or IWP2 (inhibitor of Wnt production). We firstly found that the level of Troponin T (TNNT2) expression measured by FACS was significantly higher for both 2D protocols as compared to the 3D protocol. In the three methods, iPSC-CM show sarcomeric structures. However, iPSC-CM generated in 2D protocols constantly displayed larger sarcomere lengths as compared to the 3D protocol. In addition, mRNA and protein analyses reveal higher cTNi to ssTNi ratios in the 2D protocol using IWP2 as compared to both other protocols, indicating a higher sarcomeric maturation. Differentiation of cardiac myocytes with 2D monolayer-based protocols and the use of IWP2 allows the production of higher yield of cardiac myocytes that have more suitable characteristics to study sarcomeric cardiomyopathies. PMID:28587156

  7. Data aggregation in wireless sensor networks using the SOAP protocol

    NASA Astrophysics Data System (ADS)

    Al-Yasiri, A.; Sunley, A.

    2007-07-01

    Wireless sensor networks (WSN) offer an increasingly attractive method of data gathering in distributed system architectures and dynamic access via wireless connectivity. Wireless sensor networks have physical and resource limitations, this leads to increased complexity for application developers and often results in applications that are closely coupled with network protocols. In this paper, a data aggregation framework using SOAP (Simple Object Access Protocol) on wireless sensor networks is presented. The framework works as a middleware for aggregating data measured by a number of nodes within a network. The aim of the study is to assess the suitability of the protocol in such environments where resources are limited compared to traditional networks.

  8. Computer simulation of fibrillation threshold measurements and electrophysiologic testing procedures

    NASA Technical Reports Server (NTRS)

    Grumbach, M. P.; Saxberg, B. E.; Cohen, R. J.

    1987-01-01

    A finite element model of cardiac conduction was used to simulate two experimental protocols: 1) fibrillation threshold measurements and 2) clinical electrophysiologic (EP) testing procedures. The model consisted of a cylindrical lattice whose properties were determined by four parameters: element length, conduction velocity, mean refractory period, and standard deviation of refractory periods. Different stimulation patterns were applied to the lattice under a given set of lattice parameter values and the response of the model was observed through a simulated electrocardiogram. The studies confirm that the model can account for observations made in experimental fibrillation threshold measurements and in clinical EP testing protocols.

  9. High SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging

    PubMed Central

    Motosugi, Utaroh; Hernando, Diego; Wiens, Curtis; Bannas, Peter; Reeder, Scott. B

    2017-01-01

    Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments. Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P < 0.001; and 0.94 for magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols. Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI. PMID:28190853

  10. Measuring the Effect of Soil-Transmitted Helminth Infections on Cognitive Function in Children: Systematic Review and Critical Appraisal of Evidence.

    PubMed

    Owada, Kei; Nielsen, Mark; Lau, Colleen L; Clements, Archie C A; Yakob, Laith; Soares Magalhães, Ricardo J

    2017-01-01

    Recently the role of soil-transmitted helminth (STH) infections in children's cognitive developmental impairment has been under scrutiny. We conducted a systematic review of the evidence for associations between STH infections and cognitive function of children using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses protocol. We aimed to identify the domains of cognitive function in three age strata (<24months, 24-59months and ≥60months) and critically appraise the general design protocol of the studies, with a focus on the cognitive function measurement tools used. A total of 42 papers fulfilled the inclusion criteria, including 10 studies from a recent Cochrane review. Our findings demonstrate variation in tested domains, lack of consistency in the use of measurement tools and analysis of results. Cognitive function measures in children aged under 59months have been mainly limited to domains of gross motor, fine motor and language skills, whereas in children aged 60months and above most studies tested domains such as memory and processing speed. Even within the same age group the results on the association between STH infections and measures of cognitive development were often conflicting. The current study highlights the need for methodological consensus in the use of measurement tools and data analysis protocols if the effect of STH infections on cognitive function domains in children is to be correctly established. This will be an imperative next step to generate conclusive evidence of the role of STH infections in cognitive development in children. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Physician Nonadherence With a Hepatitis C Screening Program

    PubMed Central

    Southern, William N.; Drainoni, Mari-Lynn; Smith, Bryce D.; Koppelman, Elisa; McKee, M. Diane; Christiansen, Cindy L.; Gifford, Allen L.; Weinbaum, Cindy M.; Litwin, Alain H.

    2017-01-01

    Background Testing for patients at risk for hepatitis C virus (HCV) infection is recommended, but it is unclear whether providers adhere to testing guidelines. We aimed to measure adherence to an HCV screening protocol during a multifaceted continuous intervention. Subjects and Methods Prospective cohort design to examine the associations between patient-level, physician-level, and visit-level characteristics and adherence to an HCV screening protocol. Study participants included all patients with a visit to 1 of the 3 study clinics and the physicians who cared for them. Adherence to the HCV screening protocol and patient-level, physician-level, and visit-level predictors of adherence were measured. Results A total of 8981 patients and 154 physicians were examined. Overall protocol adherence rate was 36.1%. In multivariate analysis, patient male sex (odds ratio [OR] = 1.18), new patient (OR = 1.23), morning visit (OR = 1.32), and patients’ preferred language being non-English (OR = 0.87) were significantly associated with screening adherence. There was a wide variation in overall adherence among physicians (range, 0%–92.4%). Screening adherence continuously declined from 59.1% in week 1 of the study to 13.7% in week 15 (final week). When implementing complex clinical practice guidelines, planners should address physician attitudinal barriers as well as gaps in knowledge to maximize adherence. PMID:24368717

  12. A neurocognitive approach for recovering upper extremity movement following subacute stroke: a randomized controlled pilot study.

    PubMed

    Sallés, Laia; Martín-Casas, Patricia; Gironès, Xavier; Durà, María José; Lafuente, José Vicente; Perfetti, Carlo

    2017-04-01

    [Purpose] This study aims to describe a protocol based on neurocognitive therapeutic exercises and determine its feasibility and usefulness for upper extremity functionality when compared with a conventional protocol. [Subjects and Methods] Eight subacute stroke patients were randomly assigned to a conventional (control group) or neurocognitive (experimental group) treatment protocol. Both lasted 30 minutes, 3 times a week for 10 weeks and assessments were blinded. Outcome measures included: Motor Evaluation Scale for Upper Extremity in Stroke Patients, Motricity Index, Revised Nottingham Sensory Assessment and Kinesthetic and Visual Imagery Questionnaire. Descriptive measures and nonparametric statistical tests were used for analysis. [Results] The results indicate a more favorable clinical progression in the neurocognitive group regarding upper extremity functional capacity with achievement of the minimal detectable change. The functionality results are related with improvements on muscle strength and sensory discrimination (tactile and kinesthetic). [Conclusion] Despite not showing significant group differences between pre and post-treatment, the neurocognitive approach could be a safe and useful strategy for recovering upper extremity movement following stroke, especially regarding affected hands, with better and longer lasting results. Although this work shows this protocol's feasibility with the panel of scales proposed, larger studies are required to demonstrate its effectiveness.

  13. Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population.

    PubMed

    Grover-Páez, Fernando; Cardona-Muñoz, Ernesto G; Cardona-Müller, David; Guzmán-Saldívar, Víctor H; Rodríguez-De la Cerda, Mariana; Jiménez-Cázarez, Mayra B; Totsuka-Sutto, Sylvia E; Alanis-Sánchez, Guillermo A; Ramos-Becerra, Carlos G

    2017-12-01

    The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97-190), diastolic BP was 90.9±12.9 mmHg (range: 68-120), and arm circumference was 30.8±4 cm (range: 25-38.5). The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.

  14. Wound-healing outcomes using standardized assessment and care in clinical practice.

    PubMed

    Bolton, Laura; McNees, Patrick; van Rijswijk, Lia; de Leon, Jean; Lyder, Courtney; Kobza, Laura; Edman, Kelly; Scheurich, Anne; Shannon, Ron; Toth, Michelle

    2004-01-01

    Wound-healing outcomes applying standardized protocols have typically been measured within controlled clinical trials, not natural settings. Standardized protocols of wound care have been validated for clinical use, creating an opportunity to measure the resulting outcomes. Wound-healing outcomes were explored during clinical use of standardized validated protocols of care based on patient and wound assessments. This was a prospective multicenter study of wound-healing outcomes management in real-world clinical practice. Healing outcomes from March 26 to October 31, 2001, were recorded on patients in 3 long-term care facilities, 1 long-term acute care hospital, and 12 home care agencies for wounds selected by staff to receive care based on computer-generated validated wound care algorithms. After diagnosis, wound dimensions and status were assessed using a tool adapted from the Pressure Sore Status Toolfor use on all wounds. Wound, ostomy, and continence nursing professionals accessed consistent protocols of care, via telemedicine in home care or paper forms in long-term care. A physician entered assessments into a desktop computer in the wound clinic. Based on evidence that healing proceeds faster with fewer infections in environments without gauze, the protocols generally avoided gauze dressings. Most of the 767 wounds selected to receive the standardized-protocols of care were stage III-IV pressure ulcers (n = 373; mean healing time 62 days) or full-thickness venous ulcers (n = 124; mean healing time 57 days). Partial-thickness wounds healed faster than same-etiology full-thickness wounds. These results provide benchmarks for natural-setting healing outcomes and help to define and address wound care challenges. Outcomes primarily using nongauze protocols of care matched or surpassed best previously published results on similar wounds using gauze-based protocols of care, including protocols applying gauze impregnated with growth factors or other agents.

  15. The Best of Both Worlds: Building on the COPUS and RTOP Observation Protocols to Easily and Reliably Measure Various Levels of Reformed Instructional Practice

    PubMed Central

    Lund, Travis J.; Pilarz, Matthew; Velasco, Jonathan B.; Chakraverty, Devasmita; Rosploch, Kaitlyn; Undersander, Molly; Stains, Marilyne

    2015-01-01

    Researchers, university administrators, and faculty members are increasingly interested in measuring and describing instructional practices provided in science, technology, engineering, and mathematics (STEM) courses at the college level. Specifically, there is keen interest in comparing instructional practices between courses, monitoring changes over time, and mapping observed practices to research-based teaching. While increasingly common observation protocols (Reformed Teaching Observation Protocol [RTOP] and Classroom Observation Protocol in Undergraduate STEM [COPUS]) at the postsecondary level help achieve some of these goals, they also suffer from weaknesses that limit their applicability. In this study, we leverage the strengths of these protocols to provide an easy method that enables the reliable and valid characterization of instructional practices. This method was developed empirically via a cluster analysis using observations of 269 individual class periods, corresponding to 73 different faculty members, 28 different research-intensive institutions, and various STEM disciplines. Ten clusters, called COPUS profiles, emerged from this analysis; they represent the most common types of instructional practices enacted in the classrooms observed for this study. RTOP scores were used to validate the alignment of the 10 COPUS profiles with reformed teaching. Herein, we present a detailed description of the cluster analysis method, the COPUS profiles, and the distribution of the COPUS profiles across various STEM courses at research-intensive universities. PMID:25976654

  16. Two Measurement Methods of Leaf Dry Matter Content Produce Similar Results in a Broad Range of Species

    PubMed Central

    Vaieretti, María Victoria; Díaz, Sandra; Vile, Denis; Garnier, Eric

    2007-01-01

    Background and Aims Leaf dry matter content (LDMC) is widely used as an indicator of plant resource use in plant functional trait databases. Two main methods have been proposed to measure LDMC, which basically differ in the rehydration procedure to which leaves are subjected after harvesting. These are the ‘complete rehydration’ protocol of Garnier et al. (2001, Functional Ecology 15: 688–695) and the ‘partial rehydration’ protocol of Vendramini et al. (2002, New Phytologist 154: 147–157). Methods To test differences in LDMC due to the use of different methods, LDMC was measured on 51 native and cultivated species representing a wide range of plant families and growth forms from central-western Argentina, following the complete rehydration and partial rehydration protocols. Key Results and Conclusions The LDMC values obtained by both methods were strongly and positively correlated, clearly showing that LDMC is highly conserved between the two procedures. These trends were not altered by the exclusion of plants with non-laminar leaves. Although the complete rehydration method is the safest to measure LDMC, the partial rehydration procedure produces similar results and is faster. It therefore appears as an acceptable option for those situations in which the complete rehydration method cannot be applied. Two notes of caution are given for cases in which different datasets are compared or combined: (1) the discrepancy between the two rehydration protocols is greatest in the case of high-LDMC (succulent or tender) leaves; (2) the results suggest that, when comparing many studies across unrelated datasets, differences in the measurement protocol may be less important than differences among seasons, years and the quality of local habitats. PMID:17353207

  17. Validation of the Medisana MTP Plus upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Erdem, Emre; Aydogdu, Türkan; Akpolat, Tekin

    2011-02-01

    Standard validation protocols are objective guides for healthcare providers, physicians, and patients. The purpose of this study was to test validation of the Medisana MTP Plus upper arm blood pressure (BP) measuring monitor for self-measurement according to the European Society of Hypertension International Protocol (ESH-IP2) in adults. The Medisana MTP Plus monitor is an automated and oscillometric upper arm device for home BP monitoring. Nine consecutive measurements were made according to the ESH-IP2. Overseen by an independent supervisor, measurements were recorded by two observers blinded from both each other's readings and from the device readings. The Medisana MTP Plus device fulfills the validation criteria of the ESH-IP2 for the general population. The mean (standard deviation) of the difference between the observers and the device measurements was 0.6 mmHg (5.1 mmHg) for systolic and 2.7 mmHg (3.4 mmHg) for diastolic pressures, respectively. As the Medisana MTP Plus device has achieved the required standards, it is recommended for home BP monitoring in an adult population.

  18. SU-F-J-16: Planar KV Imaging Dose Reduction Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gershkevitsh, E; Zolotuhhin, D

    Purpose: IGRT has become an indispensable tool in modern radiotherapy with kV imaging used in many departments due to superior image quality and lower dose when compared to MV imaging. Many departments use manufacturer supplied protocols for imaging which are not always optimised between image quality and radiation dose (ALARA). Methods: Whole body phantom PBU-50 (Kyoto Kagaku ltd., Japan) for imaging in radiology has been imaged on Varian iX accelerator (Varian Medical Systems, USA) with OBI 1.5 system. Manufacturer’s default protocols were adapted by modifying kV and mAs values when imaging different anatomical regions of the phantom (head, thorax, abdomen,more » pelvis, extremities). Images with different settings were independently reviewed by two persons and their suitability for IGRT set-up correction protocols were evaluated. The suitable images with the lowest mAs were then selected. The entrance surface dose (ESD) for manufacturer’s default protocols and modified protocols were measured with RTI Black Piranha (RTI Group, Sweden) and compared. Image quality was also measured with kVQC phantom (Standard Imaging, USA) for different protocols. The modified protocols have been applied for clinical work. Results: For most cases optimized protocols reduced the ESD on average by a factor of 3(range 0.9–8.5). Further reduction in ESD has been observed by applying bow-tie filter designed for CBCT. The largest reduction in dose (12.2 times) was observed for Thorax lateral protocol. The dose was slightly increased (by 10%) for large pelvis AP protocol. Conclusion: Manufacturer’s default IGRT protocols could be optimised to reduce the ESD to the patient without losing the necessary image quality for patient set-up correction. For patient set-up with planar kV imaging the bony anatomy is mostly used and optimization should focus on this aspect. Therefore, the current approach with anthropomorphic phantom is more advantageous in optimization over standard kV quality control phantoms and SNR metrics.« less

  19. Increased cardiac output elicits higher V̇O2max in response to self-paced exercise.

    PubMed

    Astorino, Todd Anthony; McMillan, David William; Edmunds, Ross Montgomery; Sanchez, Eduardo

    2015-03-01

    Recently, a self-paced protocol demonstrated higher maximal oxygen uptake versus the traditional ramp protocol. The primary aim of the current study was to further explore potential differences in maximal oxygen uptake between the ramp and self-paced protocols using simultaneous measurement of cardiac output. Active men and women of various fitness levels (N = 30, mean age = 26.0 ± 5.0 years) completed 3 graded exercise tests separated by a minimum of 48 h. Participants initially completed progressive ramp exercise to exhaustion to determine maximal oxygen uptake followed by a verification test to confirm maximal oxygen uptake attainment. Over the next 2 sessions, they performed a self-paced and an additional ramp protocol. During exercise, gas exchange data were obtained using indirect calorimetry, and thoracic impedance was utilized to estimate hemodynamic function (stroke volume and cardiac output). One-way ANOVA with repeated measures was used to determine differences in maximal oxygen uptake and cardiac output between ramp and self-paced testing. Results demonstrated lower (p < 0.001) maximal oxygen uptake via the ramp (47.2 ± 10.2 mL·kg(-1)·min(-1)) versus the self-paced (50.2 ± 9.6 mL·kg(-1)·min(-1)) protocol, with no interaction (p = 0.06) seen for fitness level. Maximal heart rate and cardiac output (p = 0.02) were higher in the self-paced protocol versus ramp exercise. In conclusion, data show that the traditional ramp protocol may underestimate maximal oxygen uptake compared with a newly developed self-paced protocol, with a greater cardiac output potentially responsible for this outcome.

  20. (LMRG): Microscope Resolution, Objective Quality, Spectral Accuracy and Spectral Un-mixing

    PubMed Central

    Bayles, Carol J.; Cole, Richard W.; Eason, Brady; Girard, Anne-Marie; Jinadasa, Tushare; Martin, Karen; McNamara, George; Opansky, Cynthia; Schulz, Katherine; Thibault, Marc; Brown, Claire M.

    2012-01-01

    The second study by the LMRG focuses on measuring confocal laser scanning microscope (CLSM) resolution, objective lens quality, spectral imaging accuracy and spectral un-mixing. Affordable test samples for each aspect of the study were designed, prepared and sent to 116 labs from 23 countries across the globe. Detailed protocols were designed for the three tests and customized for most of the major confocal instruments being used by the study participants. One protocol developed for measuring resolution and objective quality was recently published in Nature Protocols (Cole, R. W., T. Jinadasa, et al. (2011). Nature Protocols 6(12): 1929–1941). The first study involved 3D imaging of sub-resolution fluorescent microspheres to determine the microscope point spread function. Results of the resolution studies as well as point spread function quality (i.e. objective lens quality) from 140 different objective lenses will be presented. The second study of spectral accuracy looked at the reflection of the laser excitation lines into the spectral detection in order to determine the accuracy of these systems to report back the accurate laser emission wavelengths. Results will be presented from 42 different spectral confocal systems. Finally, samples with double orange beads (orange core and orange coating) were imaged spectrally and the imaging software was used to un-mix fluorescence signals from the two orange dyes. Results from 26 different confocal systems will be summarized. Time will be left to discuss possibilities for the next LMRG study.

  1. SU-E-I-57: Evaluation and Optimization of Effective-Dose Using Different Beam-Hardening Filters in Clinical Pediatric Shunt CT Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gill, K; Aldoohan, S; Collier, J

    Purpose: Study image optimization and radiation dose reduction in pediatric shunt CT scanning protocol through the use of different beam-hardening filters Methods: A 64-slice CT scanner at OU Childrens Hospital has been used to evaluate CT image contrast-to-noise ratio (CNR) and measure effective-doses based on the concept of CT dose index (CTDIvol) using the pediatric head shunt scanning protocol. The routine axial pediatric head shunt scanning protocol that has been optimized for the intrinsic x-ray tube filter has been used to evaluate CNR by acquiring images using the ACR approved CT-phantom and radiation dose CTphantom, which was used to measuremore » CTDIvol. These results were set as reference points to study and evaluate the effects of adding different filtering materials (i.e. Tungsten, Tantalum, Titanium, Nickel and Copper filters) to the existing filter on image quality and radiation dose. To ensure optimal image quality, the scanner routine air calibration was run for each added filter. The image CNR was evaluated for different kVps and wide range of mAs values using above mentioned beam-hardening filters. These scanning protocols were run under axial as well as under helical techniques. The CTDIvol and the effective-dose were measured and calculated for all scanning protocols and added filtration, including the intrinsic x-ray tube filter. Results: Beam-hardening filter shapes energy spectrum, which reduces the dose by 27%. No noticeable changes in image low contrast detectability Conclusion: Effective-dose is very much dependent on the CTDIVol, which is further very much dependent on beam-hardening filters. Substantial reduction in effective-dose is realized using beam-hardening filters as compare to the intrinsic filter. This phantom study showed that significant radiation dose reduction could be achieved in CT pediatric shunt scanning protocols without compromising in diagnostic value of image quality.« less

  2. Tongue pressure profile training for dysphagia post stroke (TPPT): study protocol for an exploratory randomized controlled trial.

    PubMed

    Steele, Catriona M; Bayley, Mark A; Péladeau-Pigeon, Melanie; Stokely, Shauna L

    2013-05-07

    It is estimated that approximately 50% of stroke survivors will experience swallowing difficulty, or dysphagia. The associated sequelae of dysphagia include dehydration, malnutrition, and aspiration pneumonia, all of which have can have serious medical consequences. To improve swallowing safety and efficiency, alternative nutritional intake methods (for example, a feeding tube) or a modified diet texture (such as pureed foods or thickened liquids) may be recommended but these modifications may negatively affect quality of life. An alternative approach to treating dysphagia has emerged over the past few years, targeting stronger lingual muscles through maximal isometric pressure tasks. Although these studies have shown promising results, thin-liquid bolus control continues to be challenging for patients with dysphagia. Previous work investigating lingual pressures when healthy participants swallow has suggested that greater task specificity in lingual exercises may yield improved results with thin liquids. This is a small, exploratory randomized clinical trial being conducted with post-stroke patients 4 to 20 weeks after onset of dysphagia secondary to impaired lingual control. At enrollment, participants are randomly assigned to one of two treatment protocols, either tongue pressure profile training (TPPT) or the control treatment, tongue pressure strength-and-accuracy training (TPSAT). Each treatment protocol consists of 24 sessions of treatment over 8 to 12 weeks with monitoring of tongue pressure as well as a baseline and outcome videofluoroscopic swallowing study. Tongue pressure measures, videofluoroscopic measures, and functional outcome measures will be obtained following training of 60 participants (30 in each condition), to determine whether TPPT yields better outcomes. This study will continue to explore options beyond tube feeding and modified diets for people with neurogenic dysphagia following stroke. Should the novel protocol, TPPT, prove to be more effective than the TPSAT protocol, this may influence standards of care and best practices for patients with dysphagia involving impaired thin-liquid control as a result of stroke. Clinicaltrials.gov http://NCT01370083.

  3. Objective and automated protocols for the evaluation of biomedical search engines using No Title Evaluation protocols.

    PubMed

    Campagne, Fabien

    2008-02-29

    The evaluation of information retrieval techniques has traditionally relied on human judges to determine which documents are relevant to a query and which are not. This protocol is used in the Text Retrieval Evaluation Conference (TREC), organized annually for the past 15 years, to support the unbiased evaluation of novel information retrieval approaches. The TREC Genomics Track has recently been introduced to measure the performance of information retrieval for biomedical applications. We describe two protocols for evaluating biomedical information retrieval techniques without human relevance judgments. We call these protocols No Title Evaluation (NT Evaluation). The first protocol measures performance for focused searches, where only one relevant document exists for each query. The second protocol measures performance for queries expected to have potentially many relevant documents per query (high-recall searches). Both protocols take advantage of the clear separation of titles and abstracts found in Medline. We compare the performance obtained with these evaluation protocols to results obtained by reusing the relevance judgments produced in the 2004 and 2005 TREC Genomics Track and observe significant correlations between performance rankings generated by our approach and TREC. Spearman's correlation coefficients in the range of 0.79-0.92 are observed comparing bpref measured with NT Evaluation or with TREC evaluations. For comparison, coefficients in the range 0.86-0.94 can be observed when evaluating the same set of methods with data from two independent TREC Genomics Track evaluations. We discuss the advantages of NT Evaluation over the TRels and the data fusion evaluation protocols introduced recently. Our results suggest that the NT Evaluation protocols described here could be used to optimize some search engine parameters before human evaluation. Further research is needed to determine if NT Evaluation or variants of these protocols can fully substitute for human evaluations.

  4. Redactions in protocols for drug trials: what industry sponsors concealed.

    PubMed

    Marquardsen, Mikkel; Ogden, Michelle; Gøtzsche, Peter C

    2018-04-01

    Objective To describe the redactions in contemporary protocols for industry-sponsored randomised drug trials with patient relevant outcomes and to evaluate whether there was a legitimate rationale for the redactions. Design Cohort study. Under the Freedom of Information Act, we requested access to trial protocols approved by a research ethics committee in Denmark from October 2012 to March 2013. We received 17 consecutive protocols, which had been redacted before we got them, and nine protocols without redactions. In five additional cases, the companies refused to let the committees give us access, and in three other cases, documents were missing. Participants Not applicable. Setting Not applicable. Main outcome measure Amount and nature of redactions in 22 predefined key protocol variables. Results The redactions were most widespread in those sections of the protocol where there is empirical evidence of substantial problems with the trustworthiness of published drug trials: data analysis, handling of missing data, detection and analysis of adverse events, definition of the outcomes, interim analyses and premature termination of the study, sponsor's access to incoming data while the study is running, ownership to the data and investigators' publication rights. The parts of the text that were redacted differed widely, both between companies and within the same company. Conclusions We could not identify any legitimate rationale for the redactions. The current mistrust in industry-sponsored drug trials can only change if the industry offers unconditional access to its trial protocols and other relevant documents and data.

  5. Improving the quality of child anthropometry: Manual anthropometry in the Body Imaging for Nutritional Assessment Study (BINA).

    PubMed

    Conkle, Joel; Ramakrishnan, Usha; Flores-Ayala, Rafael; Suchdev, Parminder S; Martorell, Reynaldo

    2017-01-01

    Anthropometric data collected in clinics and surveys are often inaccurate and unreliable due to measurement error. The Body Imaging for Nutritional Assessment Study (BINA) evaluated the ability of 3D imaging to correctly measure stature, head circumference (HC) and arm circumference (MUAC) for children under five years of age. This paper describes the protocol for and the quality of manual anthropometric measurements in BINA, a study conducted in 2016-17 in Atlanta, USA. Quality was evaluated by examining digit preference, biological plausibility of z-scores, z-score standard deviations, and reliability. We calculated z-scores and analyzed plausibility based on the 2006 WHO Child Growth Standards (CGS). For reliability, we calculated intra- and inter-observer Technical Error of Measurement (TEM) and Intraclass Correlation Coefficient (ICC). We found low digit preference; 99.6% of z-scores were biologically plausible, with z-score standard deviations ranging from 0.92 to 1.07. Total TEM was 0.40 for stature, 0.28 for HC, and 0.25 for MUAC in centimeters. ICC ranged from 0.99 to 1.00. The quality of manual measurements in BINA was high and similar to that of the anthropometric data used to develop the WHO CGS. We attributed high quality to vigorous training, motivated and competent field staff, reduction of non-measurement error through the use of technology, and reduction of measurement error through adequate monitoring and supervision. Our anthropometry measurement protocol, which builds on and improves upon the protocol used for the WHO CGS, can be used to improve anthropometric data quality. The discussion illustrates the need to standardize anthropometric data quality assessment, and we conclude that BINA can provide a valuable evaluation of 3D imaging for child anthropometry because there is comparison to gold-standard, manual measurements.

  6. Semi-quantum Dialogue Based on Single Photons

    NASA Astrophysics Data System (ADS)

    Ye, Tian-Yu; Ye, Chong-Qiang

    2018-02-01

    In this paper, we propose two semi-quantum dialogue (SQD) protocols by using single photons as the quantum carriers, where one requires the classical party to possess the measurement capability and the other does not have this requirement. The security toward active attacks from an outside Eve in the first SQD protocol is guaranteed by the complete robustness of present semi-quantum key distribution (SQKD) protocols, the classical one-time pad encryption, the classical party's randomization operation and the decoy photon technology. The information leakage problem of the first SQD protocol is overcome by the classical party' classical basis measurements on the single photons carrying messages which makes him share their initial states with the quantum party. The security toward active attacks from Eve in the second SQD protocol is guaranteed by the classical party's randomization operation, the complete robustness of present SQKD protocol and the classical one-time pad encryption. The information leakage problem of the second SQD protocol is overcome by the quantum party' classical basis measurements on each two adjacent single photons carrying messages which makes her share their initial states with the classical party. Compared with the traditional information leakage resistant QD protocols, the advantage of the proposed SQD protocols lies in that they only require one party to have quantum capabilities. Compared with the existing SQD protocol, the advantage of the proposed SQD protocols lies in that they only employ single photons rather than two-photon entangled states as the quantum carriers. The proposed SQD protocols can be implemented with present quantum technologies.

  7. Effects of a Short Drilling Implant Protocol on Osteotomy Site Temperature and Drill Torque.

    PubMed

    Mihali, Sorin G; Canjau, Silvana; Cernescu, Anghel; Bortun, Cristina M; Wang, Hom-Lay; Bratu, Emanuel

    2018-02-01

    To establish a protocol for reducing the drilling sequence during implant site preparation based on temperature and insertion torque. The traditional conventional drilling sequence (used several drills with 0.6-mm increment each time) was compared with the proposed short drilling protocol (only used 2 drills: initial and final drill). One hundred drilling osteotomies were performed in bovine and porcine bones. Sets of 2 osteotomy sites were created in 5 bone densities using 2 types of drilling protocols. Thermographic pictures were captured throughout all drilling procedures and analyzed using ThermaCAM Researcher Professional 2.10. Torque values were determined during drilling by measuring electrical input and drill speed. There were statistically significant differences in bone temperature between the conventional and short drilling protocols during implant site preparation (analysis of variance P = 0.0008). However, there were no significant differences between the 2 types of drilling protocols for both implant diameters. Implant site preparation time was significantly reduced when using the short drilling protocol compared with the conventional drilling protocol (P < 0.001). Within the limitations of the study, the short drilling protocol proposed herein may represent a safe approach for implant site preparation.

  8. Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Beime, Beate; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Hammel, Gertrud; Bramlage, Peter

    2017-05-01

    The purpose of the study was to validate the ambulatory blood pressure monitoring (ABPM) device custo screen pediatric in children aged 3 to 12 years according to the International Protocol of the European Society of Hypertension (ESH-IP revision 2010). Thirty-three children were included and systolic and diastolic blood pressure measurements were performed according to the ESH-IP. The protocol was modified for children considering data from the German Health Interview and Examination Survey for Children and Adolescents (KIGGS). The custo screen pediatric met all the requirements of the ESH-IP. The mean difference between the test device and the reference was -1.4 ± 3.0 mmHg for systolic blood pressure (SBP) and -0.7 ± 3.2 mmHg for diastolic blood pressure (DBP). For SBP and DBP, all 99 measurements were within the absolute difference of 10 mmHg between the test device and the reference. As to part 2 of the protocol, for DBP in all subjects, two out of three measurements were within 5 mmHg between the device and the standard, whereas for SBP in 32 of 33 subjects, two out of three measurements were within this range. The custo screen pediatric met all criteria of the ESH-IP review 2010, modified for children from 3 to about 12 years, and can be recommended for ABPM in children. What is Known: • Validation of blood pressure measuring devices is essential to provide patients with an accurate blood pressure measuring device. • The majority of devices has not been validated in children. What is New: • Prior to the present validation, study protocol adjustments of ESH-IP review 2010 for children were defined according to German Health Interview and Examination Survey for Children and Adolescents 2013 (KIGGS). • The custo screen pediatric test device met all criteria of ESH-IP revision 2010, modified for children, and can be recommended for ABPM in children aged 3 to about 12 years.

  9. Validation of the fully automated A&D TM-2656 blood pressure monitor according to the British Hypertension Society Protocol.

    PubMed

    Zeng, Wei-Fang; Liu, Ming; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2013-08-01

    The present study aimed to evaluate the accuracy of the fully automated oscillometric upper-arm blood pressure monitor TM-2656 according to the British Hypertension Society (BHS) Protocol 1993. We recruited individuals until there were 85 eligible participants and their blood pressure could meet the blood pressure distribution requirements specified by the BHS Protocol. For each individual, we sequentially measured the systolic and diastolic blood pressures using a mercury sphygmomanometer (two observers) and the TM-2656 device (one supervisor). Data analysis was carried out according to the BHS Protocol. The device achieved grade A. The percentage of blood pressure differences within 5, 10, and 15 mmHg was 62, 85, and 96%, respectively, for systolic blood pressure, and 71, 93, and 99%, respectively, for diastolic blood pressure. The average (±SD) of the device-observer differences was -2.1±7.8 mmHg (P<0.0001) and -1.1±5.8 mmHg (P<0.0001) for systolic and diastolic blood pressures, respectively. The A&D upper-arm blood pressure monitor TM-2656 has passed the requirements of the BHS Protocol, and can thus be recommended for blood pressure measurement.

  10. Validation of the A&D BP UA-651 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Benetti, Elisabetta; Fania, Claudio; Palatini, Paolo

    2014-02-01

    The objective of this study was to determine the accuracy of the A&D BP UA-651 device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Device evaluation was carried out in 33 patients. The mean age of the patients was 48.3±15.5 years, the mean systolic BP was 138.3±24.9 mmHg (range 90-180), the mean diastolic BP was 88.3±13.8 mmHg (range 60-108), and the mean arm circumference was 28.6±3.4 cm (range 23-36). The protocol requirements were followed precisely. The device passed all requirements, fulfilling the standards of the protocol. On average, the device underestimated the systolic BP by 0.4±4.4 mmHg and diastolic BP by 1.3±3.5 mmHg. The device-observer discrepancies were unrelated to patients' clinical characteristics. These data show that the A&D BP UA-651 device fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  11. Acupuncture to Reduce HIV-Associated Inflammation

    PubMed Central

    Swanson, Barbara; Keithley, Joyce K.; Johnson, Angela; Fogg, Louis; Adeyemi, Oluwatoyin; Sha, Beverly E.; Snell, Kimberly A.

    2015-01-01

    Background. HIV infection is associated with systemic inflammation that can increase risk for cardiovascular events. Acupuncture has been shown to have immunomodulatory effects and to improve symptoms in persons with inflammatory conditions. Objective. To test the anti-inflammatory effects of an acupuncture protocol that targets the cholinergic anti-inflammatory pathway (CAIP), a neural mechanism whose activation has been shown to reduce the release of proinflammatory cytokines, in persons with HIV-associated inflammation. Design, Setting, Participants, and Interventions. Double-blind, placebo-controlled clinical trial conducted in an outpatient clinic located in a medically underserved urban neighborhood. Twenty-five clinically-stable HIV-infected persons on antiretroviral therapy were randomized to receive once weekly CAIP-based acupuncture or sham acupuncture. Main Outcome Measures. Outcomes included plasma concentrations of high sensitivity C-reactive protein and D-dimer and fasting lipids. Results. Twenty-five participants completed the protocol (treatment group n = 12, control group n = 13). No adverse events related to the acupuncture protocol were observed. Compared to baseline values, the two groups did not significantly differ in any outcome measures at the end of the acupuncture protocol. Conclusions. CAIP-based acupuncture did not favorably modulate inflammatory or lipid parameters. Additional studies are warranted of CAIP-based protocols of different frequencies/durations. PMID:25922615

  12. SUPPLEMENT TO: STANDARD MEASUREMENT PROTOCOLS - FLORIDA RADON RESEARCH PROGRAM

    EPA Science Inventory

    The report supplements earlier published standard protocols for key measurements where data quality is vital to the Florida Radon Research Program. The report adds measurements of small canister radon flux and soil water potential to the section on soil measurements. It adds indo...

  13. Body surface posture evaluation: construction, validation and protocol of the SPGAP system (Posture evaluation rotating platform system).

    PubMed

    Schwertner, Debora Soccal; Oliveira, Raul; Mazo, Giovana Zarpellon; Gioda, Fabiane Rosa; Kelber, Christian Roberto; Swarowsky, Alessandra

    2016-05-04

    Several posture evaluation devices have been used to detect deviations of the vertebral column. However it has been observed that the instruments present measurement errors related to the equipment, environment or measurement protocol. This study aimed to build, validate, analyze the reliability and describe a measurement protocol for the use of the Posture Evaluation Rotating Platform System (SPGAP, Brazilian abbreviation). The posture evaluation system comprises a Posture Evaluation Rotating Platform, video camera, calibration support and measurement software. Two pilot studies were carried out with 102 elderly individuals (average age 69 years old, SD = ±7.3) to establish a protocol for SPGAP, controlling the measurement errors related to the environment, equipment and the person under evaluation. Content validation was completed with input from judges with expertise in posture measurement. The variation coefficient method was used to validate the measurement by the instrument of an object with known dimensions. Finally, reliability was established using repeated measurements of the known object. Expert content judges gave the system excellent ratings for content validity (mean 9.4 out of 10; SD 1.13). The measurement of an object with known dimensions indicated excellent validity (all measurement errors <1 %) and test-retest reliability. A total of 26 images were needed to stabilize the system. Participants in the pilot studies indicated that they felt comfortable throughout the assessment. The use of only one image can offer measurements that underestimate or overestimate the reality. To verify the images of objects with known dimensions the values for the width and height were, respectively, CV 0.88 (width) and 2.33 (height), SD 0.22 (width) and 0.35 (height), minimum and maximum values 24.83-25.2 (width) and 14.56 - 15.75 (height). In the analysis of different images (similar) of an individual, greater discrepancies were observed in the values found. The cervical index, for example, presented minimum and maximum values of 15.38 and 37.5, a coefficient of variation of 0.29 and a standard deviation of 6.78. The SPGAP was shown to be a valid and reliable instrument for the quantitative analysis of body posture with applicability and clinical use, since it managed to reduce several measurement errors, amongst which parallax distortion.

  14. MPLEx: a Robust and Universal Protocol for Single-Sample Integrative Proteomic, Metabolomic, and Lipidomic Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakayasu, Ernesto S.; Nicora, Carrie D.; Sims, Amy C.

    2016-05-03

    ABSTRACT Integrative multi-omics analyses can empower more effective investigation and complete understanding of complex biological systems. Despite recent advances in a range of omics analyses, multi-omic measurements of the same sample are still challenging and current methods have not been well evaluated in terms of reproducibility and broad applicability. Here we adapted a solvent-based method, widely applied for extracting lipids and metabolites, to add proteomics to mass spectrometry-based multi-omics measurements. Themetabolite,protein, andlipidextraction (MPLEx) protocol proved to be robust and applicable to a diverse set of sample types, including cell cultures, microbial communities, and tissues. To illustrate the utility of thismore » protocol, an integrative multi-omics analysis was performed using a lung epithelial cell line infected with Middle East respiratory syndrome coronavirus, which showed the impact of this virus on the host glycolytic pathway and also suggested a role for lipids during infection. The MPLEx method is a simple, fast, and robust protocol that can be applied for integrative multi-omic measurements from diverse sample types (e.g., environmental,in vitro, and clinical). IMPORTANCEIn systems biology studies, the integration of multiple omics measurements (i.e., genomics, transcriptomics, proteomics, metabolomics, and lipidomics) has been shown to provide a more complete and informative view of biological pathways. Thus, the prospect of extracting different types of molecules (e.g., DNAs, RNAs, proteins, and metabolites) and performing multiple omics measurements on single samples is very attractive, but such studies are challenging due to the fact that the extraction conditions differ according to the molecule type. Here, we adapted an organic solvent-based extraction method that demonstrated broad applicability and robustness, which enabled comprehensive proteomics, metabolomics, and lipidomics analyses from the same sample.« less

  15. Potentially inappropriate medicines in elderly hospitalised patients according to the EU(7)-PIM list, STOPP version 2 criteria and comprehensive protocol.

    PubMed

    Mucalo, Iva; Hadžiabdić, Maja Ortner; Brajković, Andrea; Lukić, Sonja; Marić, Patricia; Marinović, Ivana; Bačić-Vrca, Vesna

    2017-08-01

    The aim of this study was to measure the prevalence of potentially inappropriate medications (PIMs) by using the EU(7)-PIM list, STOPP (Screening Tool of Older Persons' potentially inappropriate Prescriptions) version 2 criteria and the new comprehensive protocol. This prospective study involved a sample of 276 consecutive elderly patients discharged from the university teaching hospital. Age, gender, diagnoses, medication history and medicines at discharge were recorded. The main outcome measure was the prevalence of PIMs according to each set of criteria: EU(7)-PIM list, STOPP version 2 criteria and comprehensive protocol. The median patient age (range) was 74 (65-92) years. The median number of prescribed medications was 7 (1-17). STOPP identified 393 PIMs affecting 190 patients (69%), EU(7)-PIM list identified 330 PIMs in 184 patients (66.7%) whilst the comprehensive protocol identified 134 PIMs in 102 patients (37%). STOPP version 2 criteria identified significantly more PIMs per patient than the other two protocols (p < 0.001). Gender (p = 0.002), glomerular filtration rate (p = 0.039) and number of comorbidities (p = 0.001) were associated with the proportion of PIMs for the STOPP version 2 criteria only. A very high PIM prevalence at discharge was reported suggesting the urgent need for actions to reduce them. STOPP version 2 criteria identified significantly more PIMs than the EU(7)-PIM list and the comprehensive protocol and was found as a more sensitive tool for PIM detection.

  16. Exercise with vibration dumb-bell enhances neuromuscular excitability measured using TMS.

    PubMed

    Fowler, D E; Tok, M I; Colakoğlu, M; Bademkiran, F; Colakoğlu, Z

    2010-09-01

    The purpose of the study was to examine the effects of exercise without vibration and exercise with vibration (27 Hz) on the cortical silent period (CSP) and cortical motor threshold (CMT) measured using transcranial magnetic stimulation (TMS). In 22 university athletes, a circular coil attached to a TMS stimulator was applied over the contralateral motor cortex of the target forearm. Resting cortical motor thresholds for dominant and non-dominant extremities were measured for each participant. Then, 15 biceps curls (15 flexion and 15 extension movements) were performed with the dominant arm using a single vibration dumbbell with the vibration turned off. On a different day, the same biceps curl protocol was performed with the dumbbell vibrating at 27 Hz (2 mm amplitude). A supra-threshold TMS stimulus (1.5x CMT) was delivered while participants were voluntarily contracting the flexor digitorum sublimus muscle (30% MVC grip strength) to determine cortical silent periods before and after each upper extremity exercise protocol. Cortical motor thresholds were measured at rest and after the vibration exercise protocol. All subjects completed the study protocol as designed. After TMS, the CSP in the dominant (exercised) extremities increased after exercise without vibration from a resting (pre-exercise) mean of 57.3 ms to 70.4 ms (P<0.05) and after exercise with vibration, the CSP decreased to a mean of 49.4 ms (P<0.02). The CSP in the non-dominant (unexercised) extremities decreased from resting values of 75.6 ms to 69.3 ms (P=0.935) after the exercise-only protocol and decreased to 49.4 ms (P<0.01) after the vibration exercise protocol. The cortical motor threshold in exercised extremities decreased from a resting mean of 41.4 μV to a postvibration exercise mean of 38.6 μV (P<0.01). In non-exercised extremities, the CMT also decreased, from mean of 43.5 μV to 39.9 μV after the vibration-exercise (P<0.01). Vibration exercise enhances bilateral corticospinal excitability, as demonstrated by a shortened cortical silent period and lower cortical motor threshold in both exercised and non-exercised extremities.

  17. Validation of the Microlife BP A3 PC upper arm blood pressure monitor in patients with diabetes mellitus according to the ANSI/AAMI/ISO 81060-2: 2013 protocol.

    PubMed

    Beime, Beate; Krüger, Ralf; Hammel, Gertrud; Bramlage, Peter; Deutsch, Cornelia

    2018-02-01

    The aim of the present study was to validate the blood pressure (BP) measurement device, Microlife BP A3 PC, in patients with diabetes mellitus, according to the ANSI/AAMI/ISO 81060-2:2013 protocol. In 85 individuals aged 56-88 years, with predefined criteria for diabetes mellitus, BP measurements on the upper arm were performed alternately using the Microlife BP A3 PC and a standard mercury reference sphygmomanometer. A total of 333 comparisons were included for analysis. The mean difference between the Microlife BP A3 PC and the reference was -1.5±6.3 mmHg for systolic BP (SBP) and -1.3±5.2 mmHg for diastolic BP (DBP) according to criterion 1 of the protocol. For SBP, a total of 209 of the 333 measurements were within the range of 5 mmHg (62.8%), whereas the corresponding numbers for DBP were 232 of 333 (69.7%). For criterion 2, the intraindividual differences for the test device and the reference were -1.50±4.73 mmHg for SBP and -1.30±4.55 mmHg for DBP, thus being within the defined ranges provided by the protocol. The Microlife BP A3 PC fulfilled the requirements of criteria 1 and 2 of the ANSI/AAMI/ISO 81060-2:2013 protocol and can also be recommended for BP measurement in diabetic patients.

  18. Validation of the Pangao PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Zhao, Hairong; Qiao, Weichang; Zhang, Rui; Cui, Peng; Hou, Fanglin; Zhang, Wenli

    2018-02-01

    The aim of this study was to validate the PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. A total of 33 participants were initially included on the basis of the ESH-IP, followed by examination of 85 participants according to the BHS protocol. The procedures and analysis methods of the protocols were followed precisely with left arm/wrist sequential measurements by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The device passed the ESH-IP with an average difference of 1.45±6.46 mmHg for systolic blood pressure and 1.25±5.10 mmHg for diastolic blood pressure. Furthermore, the A/A grade of the BHS protocol was achieved with an average difference of 1.84±6.94 mmHg for systolic blood pressure and 1.15±6.49 mmHg for diastolic blood pressure, and thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800A36 passed the requirements of the ESH-IP revision 2010 and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  19. Constitutive properties of adult mammalian cardiac muscle cells

    NASA Technical Reports Server (NTRS)

    Zile, M. R.; Richardson, K.; Cowles, M. K.; Buckley, J. M.; Koide, M.; Cowles, B. A.; Gharpuray, V.; Cooper, G. 4th

    1998-01-01

    BACKGROUND: The purpose of this study was to determine whether changes in the constitutive properties of the cardiac muscle cell play a causative role in the development of diastolic dysfunction. METHODS AND RESULTS: Cardiocytes from normal and pressure-hypertrophied cats were embedded in an agarose gel, placed on a stretching device, and subjected to a change in stress (sigma), and resultant changes in cell strain (epsilon) were measured. These measurements were used to examine the passive elastic spring, viscous damping, and myofilament activation. The passive elastic spring was assessed in protocol A by increasing the sigma on the agarose gel at a constant rate to define the cardiocyte sigma-versus-epsilon relationship. Viscous damping was assessed in protocol B from the loop area between the cardiocyte sigma-versus-epsilon relationship during an increase and then a decrease in sigma. In both protocols, myofilament activation was minimized by a reduction in [Ca2+]i. Myofilament activation effects were assessed in protocol C by defining cardiocyte sigma versus epsilon during an increase in sigma with physiological [Ca2+]i. In protocol A, the cardiocyte sigma-versus-epsilon relationship was similar in normal and hypertrophied cells. In protocol B, the loop area was greater in hypertrophied than normal cardiocytes. In protocol C, the sigma-versus-epsilon relation in hypertrophied cardiocytes was shifted to the left compared with normal cells. CONCLUSIONS: Changes in viscous damping and myofilament activation in combination may cause pressure-hypertrophied cardiocytes to resist changes in shape during diastole and contribute to diastolic dysfunction.

  20. Secure quantum communication using classical correlated channel

    NASA Astrophysics Data System (ADS)

    Costa, D.; de Almeida, N. G.; Villas-Boas, C. J.

    2016-10-01

    We propose a secure protocol to send quantum information from one part to another without a quantum channel. In our protocol, which resembles quantum teleportation, a sender (Alice) and a receiver (Bob) share classical correlated states instead of EPR ones, with Alice performing measurements in two different bases and then communicating her results to Bob through a classical channel. Our secure quantum communication protocol requires the same amount of classical bits as the standard quantum teleportation protocol. In our scheme, as in the usual quantum teleportation protocol, once the classical channel is established in a secure way, a spy (Eve) will never be able to recover the information of the unknown quantum state, even if she is aware of Alice's measurement results. Security, advantages, and limitations of our protocol are discussed and compared with the standard quantum teleportation protocol.

  1. Measurement of Salivary Cortisone to Assess the Adequacy of Hydrocortisone Replacement.

    PubMed

    Raff, Hershel

    2016-04-01

    This Commentary discusses the study of Debono et al (19) and focuses on the potential use of multiple salivary cortisone measurements to evaluate the adequacy of hydrocortisone replacement therapy. Salivary cortisone, typically measured using liquid chromatography-tandem mass spectrometry, accurately reflects plasma free cortisol because of the expression of 11-β -hydroxysteroid dehydrogenase in the salivary gland. Debono et al showed that multiple, sequential salivary cortisone measurements obtained over a 12-hour period correlated with plasma free cortisol in subjects receiving intravenous or oral hydrocortisone (authentic cortisol). Hopefully, these studies will lead to a simplified protocol with fewer samples for the measurement of salivary cortisone that can reliably assess the adequacy of hydrocortisone replacement in patients with adrenal insufficiency. This protocol has to be cost-effective and be feasible to obtain timed salivary samples accurately at home. It would be a significant advance to be able to monitor hydrocortisone replacement therapy with as few as one or two salivary cortisone measurements.

  2. Software-defined Radio Based Measurement Platform for Wireless Networks

    PubMed Central

    Chao, I-Chun; Lee, Kang B.; Candell, Richard; Proctor, Frederick; Shen, Chien-Chung; Lin, Shinn-Yan

    2015-01-01

    End-to-end latency is critical to many distributed applications and services that are based on computer networks. There has been a dramatic push to adopt wireless networking technologies and protocols (such as WiFi, ZigBee, WirelessHART, Bluetooth, ISA100.11a, etc.) into time-critical applications. Examples of such applications include industrial automation, telecommunications, power utility, and financial services. While performance measurement of wired networks has been extensively studied, measuring and quantifying the performance of wireless networks face new challenges and demand different approaches and techniques. In this paper, we describe the design of a measurement platform based on the technologies of software-defined radio (SDR) and IEEE 1588 Precision Time Protocol (PTP) for evaluating the performance of wireless networks. PMID:27891210

  3. Software-defined Radio Based Measurement Platform for Wireless Networks.

    PubMed

    Chao, I-Chun; Lee, Kang B; Candell, Richard; Proctor, Frederick; Shen, Chien-Chung; Lin, Shinn-Yan

    2015-10-01

    End-to-end latency is critical to many distributed applications and services that are based on computer networks. There has been a dramatic push to adopt wireless networking technologies and protocols (such as WiFi, ZigBee, WirelessHART, Bluetooth, ISA100.11a, etc. ) into time-critical applications. Examples of such applications include industrial automation, telecommunications, power utility, and financial services. While performance measurement of wired networks has been extensively studied, measuring and quantifying the performance of wireless networks face new challenges and demand different approaches and techniques. In this paper, we describe the design of a measurement platform based on the technologies of software-defined radio (SDR) and IEEE 1588 Precision Time Protocol (PTP) for evaluating the performance of wireless networks.

  4. Comment on 'Quantum direct communication with authentication'

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Zhan-jun; Key Laboratory of Optoelectronic Information Acquisition and Manipulation of Ministry of Education of China, School of Physics and Material Science, Anhui University, Hefei 230039; Liu, Jun

    2007-02-15

    Two protocols of quantum direct communication with authentication [Phys. Rev. A 73, 042305 (2006)] were recently proposed by Lee, Lim, and Yang. In this paper we will show that in the two protocols the authenticator Trent should be prevented from knowing the secret message. The first protocol can be eavesdropped on by Trent using the intercept-measure-resend attack, while the second protocol can be eavesdropped on by Trent using a simple single-qubit measurement. To fix these leaks, we revise the original versions of the protocols by using the Pauli Z operation {sigma}{sub z} instead of the original bit-flip operation X. Asmore » a consequence, the attacks we present can be prevented and accordingly the protocol securities are improved.« less

  5. Quantum cryptography without switching.

    PubMed

    Weedbrook, Christian; Lance, Andrew M; Bowen, Warwick P; Symul, Thomas; Ralph, Timothy C; Lam, Ping Koy

    2004-10-22

    We propose a new coherent state quantum key distribution protocol that eliminates the need to randomly switch between measurement bases. This protocol provides significantly higher secret key rates with increased bandwidths than previous schemes that only make single quadrature measurements. It also offers the further advantage of simplicity compared to all previous protocols which, to date, have relied on switching.

  6. USDA-ARS GRACEnet Project Protocols, Chapter 3. Chamber-based trace gas flux measurements4

    USDA-ARS?s Scientific Manuscript database

    This protocol addresses N2O, CO2 and CH4 flux measurement by soil chamber methodology. The reactivities of other gasses of interest such as NOx O3, CO, and NH3 will require different chambers and associated instrumentation. Carbon dioxide is included as an analyte with this protocol; however, when p...

  7. Use of cardiocerebral resuscitation or AHA/ERC 2005 Guidelines is associated with improved survival from out-of-hospital cardiac arrest: a systematic review and meta-analysis.

    PubMed

    Salmen, Marcus; Ewy, Gordon A; Sasson, Comilla

    2012-01-01

    To determine whether the use of cardiocerebral resuscitation (CCR) or AHA/ERC 2005 Resuscitation Guidelines improved patient outcomes from out-of-hospital cardiac arrest (OHCA) compared to older guidelines. Systematic review and meta-analysis. MEDLINE, EMBASE, Web of Science and the Cochrane Library databases. We also hand-searched study references and consulted experts. Design: randomised controlled trials and observational studies. OHCA patients, age >17 years. 'Control' protocol versus 'Study' protocol. 'Control' protocol defined as AHA/ERC 2000 Guidelines for cardiopulmonary resuscitation (CPR). 'Study' protocol defined as AHA/ERC 2005 Guidelines for CPR, or a CCR protocol. Survival to hospital discharge. High-quality or medium-quality studies, as measured by the Newcastle Ottawa Scale using predefined categories. Twelve observational studies met inclusion criteria. All the three studies using CCR demonstrated significantly improved survival compared to use of AHA 2000 Guidelines, as did five of the nine studies using AHA/ERC 2005 Guidelines. Pooled data demonstrate that use of a CCR protocol has an unadjusted OR of 2.26 (95% CI 1.64 to 3.12) for survival to hospital discharge among all cardiac arrest patients. Among witnessed ventricular fibrillation/ventricular tachycardia (VF/VT) patients, CCR increased survival by an OR of 2.98 (95% CI 1.92 to 4.62). Studies using AHA/ERC 2005 Guidelines showed an overall trend towards increased survival, but significant heterogeneity existed among these studies. We demonstrate an association with improved survival from OHCA when CCR protocols or AHA/ERC 2005 Guidelines are compared to use of older guidelines. In the subgroup of patients with witnessed VF/VT, there was a threefold increase in OHCA survival when CCR was used. CCR appears to be a promising resuscitation protocol for Emergency Medical Services providers in increasing survival from OHCA. Future research will need to be conducted to directly compare AHA/ERC 2010 Guidelines with the CCR approach.

  8. Validation of the Omron HEM-7201 upper arm blood pressure monitor, for self-measurement in a high-altitude environment, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Cho, K; Tian, M; Lan, Y; Zhao, X; Yan, L L

    2013-08-01

    Few studies have been conducted on blood pressure monitors and their use at high altitude. This study is the first to evaluate the accuracy of an automatic blood pressure monitor in a high-altitude environment following a standard validation protocol. The Omron HEM-7201 upper arm blood pressure monitor was tested for accuracy in Lhasa, Tibet, China (3650 m above sea level) according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP2). Thirty-three participants received 9-10 sequential blood pressure measurements alternating between a mercury sphygmomanometer and the device. The mean device-observer measurement difference was 1.0±5.9 mm Hg for systolic blood pressure (SBP) and -3.1±4.6 mm Hg for diastolic blood pressure (DBP). Of the 99 measurement pairs analyzed, 72, 90 and 97 device readings were within 5, 10 and 15 mm Hg, respectively, of the observer measurements for SBP, and 68, 92 and 99 readings for DBP. The number of participants with at least two out of three measurements within 5 mm Hg was 27 for SBP and 25 for DBP. Three participants had no measurements within 5 mm Hg for either SBP or DBP. As a result, the Omron HEM-7201 passes the ESH-IP2 validation criteria and can therefore be recommended for use in adults in this setting.

  9. Obtaining continuous BrAC/BAC estimates in the field: A hybrid system integrating transdermal alcohol biosensor, Intellidrink smartphone app, and BrAC Estimator software tools.

    PubMed

    Luczak, Susan E; Hawkins, Ashley L; Dai, Zheng; Wichmann, Raphael; Wang, Chunming; Rosen, I Gary

    2018-08-01

    Biosensors have been developed to measure transdermal alcohol concentration (TAC), but converting TAC into interpretable indices of blood/breath alcohol concentration (BAC/BrAC) is difficult because of variations that occur in TAC across individuals, drinking episodes, and devices. We have developed mathematical models and the BrAC Estimator software for calibrating and inverting TAC into quantifiable BrAC estimates (eBrAC). The calibration protocol to determine the individualized parameters for a specific individual wearing a specific device requires a drinking session in which BrAC and TAC measurements are obtained simultaneously. This calibration protocol was originally conducted in the laboratory with breath analyzers used to produce the BrAC data. Here we develop and test an alternative calibration protocol using drinking diary data collected in the field with the smartphone app Intellidrink to produce the BrAC calibration data. We compared BrAC Estimator software results for 11 drinking episodes collected by an expert user when using Intellidrink versus breath analyzer measurements as BrAC calibration data. Inversion phase results indicated the Intellidrink calibration protocol produced similar eBrAC curves and captured peak eBrAC to within 0.0003%, time of peak eBrAC to within 18min, and area under the eBrAC curve to within 0.025% alcohol-hours as the breath analyzer calibration protocol. This study provides evidence that drinking diary data can be used in place of breath analyzer data in the BrAC Estimator software calibration procedure, which can reduce participant and researcher burden and expand the potential software user pool beyond researchers studying participants who can drink in the laboratory. Copyright © 2017. Published by Elsevier Ltd.

  10. Comparison of calculation and experiment implicates significant electrostatic contributions to the binding stability of barnase and barstar.

    PubMed

    Dong, Feng; Vijayakumar, M; Zhou, Huan-Xiang

    2003-07-01

    The contributions of electrostatic interactions to the binding stability of barnase and barstar were studied by the Poisson-Boltzmann model with three different protocols: a), the dielectric boundary specified as the van der Waals (vdW) surface of the protein along with a protein dielectric constant (epsilon (p)) of 4; b), the dielectric boundary specified as the molecular (i.e., solvent-exclusion (SE)) surface along with epsilon (p) = 4; and c), "SE + epsilon (p) = 20." The "vdW + epsilon (p) = 4" and "SE + epsilon (p) = 20" protocols predicted an overall electrostatic stabilization whereas the "SE + epsilon (p) = 4" protocol predicted an overall electrostatic destabilization. The "vdW + epsilon (p) = 4" protocol was most consistent with experiment. It quantitatively reproduced the observed effects of 17 mutations neutralizing charged residues lining the binding interface and the measured coupling energies of six charge pairs across the interface and reasonably rationalized the experimental ionic strength and pH dependences of the binding constant. In contrast, the "SE + epsilon (p) = 4" protocol predicted significantly larger coupling energies of charge pairs whereas the "SE + epsilon (p) = 20" protocol did not predict any pH dependence. This study calls for further scrutiny of the different Poisson-Boltzmann protocols and demonstrates potential danger in drawing conclusions on electrostatic contributions based on a particular calculation protocol.

  11. Reliable protocol for shear wave elastography of lower limb muscles at rest and during passive stretching.

    PubMed

    Dubois, Guillaume; Kheireddine, Walid; Vergari, Claudio; Bonneau, Dominique; Thoreux, Patricia; Rouch, Philippe; Tanter, Mickael; Gennisson, Jean-Luc; Skalli, Wafa

    2015-09-01

    Development of shear wave elastography gave access to non-invasive muscle stiffness assessment in vivo. The aim of the present study was to define a measurement protocol to be used in clinical routine for quantifying the shear modulus of lower limb muscles. Four positions were defined to evaluate shear modulus in 10 healthy subjects: parallel to the fibers, in the anterior and posterior aspects of the lower limb, at rest and during passive stretching. Reliability was first evaluated on two muscles by three operators; these measurements were repeated six times. Then, measurement reliability was compared in 11 muscles by two operators; these measurements were repeated three times. Reproducibility of shear modulus was 0.48 kPa and repeatability was 0.41 kPa, with all muscles pooled. Position did not significantly influence reliability. Shear wave elastography appeared to be an appropriate and reliable tool to evaluate the shear modulus of lower limb muscles with the proposed protocol. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Validation of the iHealth BP3 upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Chen, Can; Shang, Fujun; Wang, Jiepin; Chen, Jianghong; Ji, Na; Wan, Yi

    2012-12-01

    This study aimed to evaluate the performance of the iHealth BP3 upper-arm blood pressure monitor, which is designed for clinic use and self-measurement of blood pressure using Apple touch devices as an interface. The European Society of Hypertension International Protocol (ESH-IP) revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. Ninty-nine couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The 33 participants, age 47.1±12.3 years (age range 27-69 years) and arm circumference 30.0±4.4 cm, had a mean systolic blood pressure (SBP) of 143.9±27.4 mmHg and a mean diastolic blood pressure (DBP) of 90.1±18.3 mmHg. The device passed all of the requirements fulfilling the standards of the protocol, and the mean±SD device-observer difference was 2.8±4.2 mmHg for SBP and -0.4±3.5 mmHg for DBP. According to the results of the validation study on the basis of the ESH-IP revision 2010, the iHealth BP3 can be recommended for clinic use and self-measurement in an adult population. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  13. Critical examination of evidence for the nutritional status of children in Papua New Guinea - a systematic review.

    PubMed

    McGlynn, Peter J; Renzaho, Andre μΝ; Pham, Minh D; Toole, Mike; Fisher, Jane; Luchters, Stanley

    2018-01-01

    Undernutrition remains a significant cause of childhood illness, poor growth, development, and death in Papua New Guinea (PNG). Studies on child nutritional outcomes in PNG vary by design, measurement protocols and quality. We conducted a systematic review to assess the evidence for the prevalence of child undernutrition across different study populations, geographical locations and time periods. Six electronic databases and additional grey literature were searched for articles describing the nutritional status by wasting, stunting and underweight, of PNG children under five years of age, published between 1990 and April 2015. Prevalence data using different scales of measurement and reference populations were standardized according to WHO protocols. The search yielded 566 articles, of which, 31 studies met the inclusion criteria. The prevalence of child undernutrition varied from 1% to 76% for wasting (median 11%), 5% to 92% for stunting (median 51%), and 14% to 59% for underweight (median 32%). Wide variations exist according to the index used for measurement, the population characteristics and the geographical region in which they live. Prevalence estimates increase significantly when data using different scales of measurement and population references are standardized to the WHO protocols. Child undernutrition in PNG is regionally variable due to a complex interplay of poverty, disease, food-security, cultural, environmental and sociopolitical issues requiring a complex mix of solutions by governments, health systems and local communities. Area- specific surveys using multiple measures are necessary to inform local solutions for this important problem.

  14. A comparison of maximal bioenergetic enzyme activities obtained with commonly used homogenization techniques.

    PubMed

    Grace, M; Fletcher, L; Powers, S K; Hughes, M; Coombes, J

    1996-12-01

    Homogenization of tissue for analysis of bioenergetic enzyme activities is a common practice in studies examining metabolic properties of skeletal muscle adaptation to disease, aging, inactivity or exercise. While numerous homogenization techniques are in use today, limited information exists concerning the efficacy of specific homogenization protocols. Therefore, the purpose of this study was to compare the efficacy of four commonly used approaches to homogenizing skeletal muscle for analysis of bioenergetic enzyme activity. The maximal enzyme activity (Vmax) of citrate synthase (CS) and lactate dehydrogenase (LDH) were measured from homogenous muscle samples (N = 48 per homogenization technique) and used as indicators to determine which protocol had the highest efficacy. The homogenization techniques were: (1) glass-on-glass pestle; (2) a combination of a mechanical blender and a teflon pestle (Potter-Elvehjem); (3) a combination of the mechanical blender and a biological detergent; and (4) the combined use of a mechanical blender and a sonicator. The glass-on-glass pestle homogenization protocol produced significantly higher (P < 0.05) enzyme activities compared to all other protocols for both enzymes. Of the four protocols examined, the data demonstrate that the glass-on-glass pestle homogenization protocol is the technique of choice for studying bioenergetic enzyme activity in skeletal muscle.

  15. Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol.

    PubMed

    Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Chahine, Mirna N; Ibanez, Isabel; Assemani, Nathalie; Asmar, Roland

    2014-01-01

    Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. The four devices measure brachial blood pressure (BP) using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg). The protocol procedures were followed precisely in each of the four studies. All four tested devices passed the validation process. The mean differences between the device and mercury readings were: -1.8±5.1 mmHg and -0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and -1.2±4.3 mmHg for the Omron HEM-7420 device; -0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device. Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly.

  16. Two Different Fatigue Protocols and Lower Extremity Motion Patterns During a Stop-Jump Task

    PubMed Central

    Quammen, David; Cortes, Nelson; Van Lunen, Bonnie L.; Lucci, Shawn; Ringleb, Stacie I.; Onate, James

    2012-01-01

    Context: Altered neuromuscular control strategies during fatigue probably contribute to the increased incidence of non-contact anterior cruciate ligament injuries in female athletes. Objective: To determine biomechanical differences between 2 fatigue protocols (slow linear oxidative fatigue protocol [SLO-FP] and functional agility short-term fatigue protocol [FAST-FP]) when performing a running-stop-jump task. Design: Controlled laboratory study. Setting: Laboratory. Patients or Other Participants: A convenience sample of 15 female soccer players (age = 19.2 ±0.8 years, height = 1.67±0.05m, mass = 61.7 + 8.1 kg) without injury participated. Intervention(s): Five successful trials of a running–stop-jump task were obtained prefatigue and postfatigue during the 2 protocols. For the SLO-FP, a peak oxygen consumption (V˙o2peak) test was conducted before the fatigue protocol. Five minutes after the conclusion of the V˙o2peak test, participants started the fatigue protocol by performing a 30-minute interval run. The FAST-FP consisted of 4 sets of a functional circuit. Repeated 2 (fatigue protocol) × 2 (time) analyses of variance were conducted to assess differences between the 2 protocols and time (prefatigue, postfatigue). Main Outcome Measure(s): Kinematic and kinetic measures of the hip and knee were obtained at different times while participants performed both protocols during prefatigue and postfatigue. Results: Internal adduction moment at initial contact (IC) was greater during FAST-FP (0.064 ±0.09 Nm/kgm) than SLO-FP (0.024±0.06 Nm/kgm) (F1,14 = 5.610, P=.03). At IC, participants had less hip flexion postfatigue (44.7°±8.1°) than prefatigue (50.1°±9.5°) (F1,14 = 16.229, P=.001). At peak vertical ground reaction force, participants had less hip flexion postfatigue (44.7°±8.4°) than prefatigue (50.4°±10.3°) (F1,14 = 17.026, P=.001). At peak vertical ground reaction force, participants had less knee flexion postfatigue (−35.9°±6.5°) than prefatigue (−38.8°±5.03°) (F1,14 = 11.537, P=.001). Conclusions: Our results demonstrated a more erect landing posture due to a decrease in hip and knee flexion angles in the postfatigue condition. The changes were similar between protocols; however, the FAST-FP was a clinically applicable 5-minute protocol, whereas the SLO-FP lasted approximately 45 minutes. PMID:22488228

  17. Three-dimensional black-blood multi-contrast carotid imaging using compressed sensing: a repeatability study.

    PubMed

    Yuan, Jianmin; Usman, Ammara; Reid, Scott A; King, Kevin F; Patterson, Andrew J; Gillard, Jonathan H; Graves, Martin J

    2018-02-01

    The purpose of this work is to evaluate the repeatability of a compressed sensing (CS) accelerated multi-contrast carotid protocol at 3 T. Twelve volunteers and eight patients with carotid disease were scanned on a 3 T MRI scanner using a CS accelerated 3-D black-blood multi-contrast protocol which comprises T 1 w, T 2 w and PDw without CS, and with a CS factor of 1.5 and 2.0. The volunteers were scanned twice, the lumen/wall area and wall thickness were measured for each scan. Eight patients were scanned once, the inter/intra-observer reproducibility of the measurements was calculated. In the repeated volunteer scans, the interclass correlation coefficient (ICC) for the wall area measurement using a CS factor of 1.5 in PDw, T 1 w and T 2 w were 0.95, 0.81, and 0.97, respectively. The ICC for lumen area measurement using a CS factor of 1.5 in PDw, T 1 w and T 2 w were 0.96, 0.92, and 0.96, respectively. In patients, the ICC for inter/intra-observer measurements of lumen/wall area, and wall thickness were all above 0.81 in all sequences. The results show a CS accelerated 3-D black-blood multi-contrast protocol is a robust and reproducible method for carotid imaging. Future protocol design could use CS to reduce the scanning time.

  18. Comparison of Head Elevation Protocols Following Femoral Artery Sheath Removal After Coronary Angiography.

    PubMed

    Olson, Nancy C

    2016-06-01

    To compare 2 standard protocols for head elevation following removal of a femoral artery sheath after coronary angiography and their effects on bleeding complications and reported levels of back pain. One protocol involved flat supine bed rest; the other allowed progressive head elevation. A prospective comparative study of 80 adult patients undergoing coronary angiography via the femoral approach. The Numeric Rating Scale was used as the measure of reported pain. No bleeding complications occurred in either group. Both groups had very low mean pain scores. Repeated-measures analysis demonstrated that the experience of pain differed significantly over time by location (F5,70 = 3.864, P = .004), with a notable decrease in pain scores more than 1 hour after sheath removal at the location that used the progressive head elevation protocol. Patients' satisfaction scores after discharge did not differ significantly between the 2 groups. Patients with a history of chronic back pain had consistently higher pain scores, but those pain scores did not differ significantly by location (or protocol). It appears that using a progressive head-elevation protocol within the first 3 hours after diagnostic angiography is not associated with an increased risk of bleeding complications at the access site and warrants further exploration in the mitigation of back pain associated with prolonged supine bed rest. ©2016 American Association of Critical-Care Nurses.

  19. Two-qubit correlations revisited: average mutual information, relevant (and useful) observables and an application to remote state preparation

    NASA Astrophysics Data System (ADS)

    Giorda, Paolo; Allegra, Michele

    2017-07-01

    Understanding how correlations can be used for quantum communication protocols is a central goal of quantum information science. While many authors have linked the global measures of correlations such as entanglement or discord to the performance of specific protocols, in general the latter may require only correlations between specific observables. In this work, we first introduce a general measure of correlations for two-qubit states, based on the classical mutual information between local observables. Our measure depends on the state’s purity and the symmetry in the correlation distribution, according to which we provide a classification of maximally mixed marginal states (MMMS). We discuss the complementarity relation between correlations and coherence. By focusing on a simple yet paradigmatic example, i.e. the remote state preparation protocol, we introduce a method to systematically define the proper protocol-tailored measures of the correlations. The method is based on the identification of those correlations that are relevant (useful) for the protocol. On the one hand, the approach allows the role of the symmetry of the correlation distribution to be discussed in determining the efficiency of the protocol, both for MMMS and general two-qubit quantum states, and on the other hand, it allows an optimized protocol for non-MMMS to be devised, which is more efficient with respect to the standard one. Overall, our findings clarify how the key resources in simple communication protocols are the purity of the state used and the symmetry of the correlation distribution.

  20. Elementary teachers' ideas about, planning for and implementation of learner-directed and teacher-directed inquiry: A mixed methods study

    NASA Astrophysics Data System (ADS)

    Biggers, Mandy Sue

    Using a framework for variations of classroom inquiry (National Research Council [NRC], 2000, p. 29), this study explored 40 inservice elementary teachers' planning, modification, and enactment of kit-based science curriculum materials. As part of the study, a new observation protocol was modified from an existing protocol (Practices of Science Observation Protocol [P-SOP]) to measure the amount of teacher direction in science inquiry lessons (Practices of Science Observation Protocol + Directedness [P-SOPd]). An embedded mixed methods design was employed to investigate four questions: 1. How valid and reliable is the P-SOPd? 2. In what ways do inservice elementary teachers adapt existing elementary science curriculum materials across the inquiry continuum? 3. What is the relationship between the overall quality of inquiry and variations of inquiry in elementary teachers' enacted science instruction? 4. How do inservice elementary teachers' ideas about the inquiry continuum influence their adaptation of elementary science curriculum materials? Each teacher chose three lessons from a science unit for video-recorded observation, and submitted lesson plans for the three lessons. Lesson plans and videos were scored using the P-SOPd. The scores were also compared between the two protocols to determine if a correlation existed between the level of inquiry (measured on the P-SOP) and the amount of teacher direction (measured on the P-SOPd). Findings indicated no significant differences between planned and enacted lessons for the amount of teacher direction, but a correlation existed between the level of inquiry and the amount of teacher direction. In effect, the elementary teachers taught their science curriculum materials with a high level of fidelity for both the features of inquiry and the amount of teacher direction. A smaller group of three case study teachers were followed for the school year to give a more in-depth explanation of the quantitative findings. Case study findings revealed that the teachers' science instruction was teacher-directed while their conceptions of inquiry were student-directed. This study contributes to existing research on preservice teachers' learning about the continuum (Biggers & Forbes, 2012) and inservice teachers' ideas about the five features of inquiry (Biggers & Forbes, in press).

  1. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candela-Juan, C., E-mail: ccanjuan@gmail.com; Vijande, J.; García-Martínez, T.

    2015-08-15

    Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate ofmore » the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW chambers, differ by less than 1.1% for any applicator size when compared to the output factors that were measured with the A20 chamber. Conclusions: Measurements using both dosimetric protocols are consistent, once the overall uncertainties are considered. There is also consistency between measurements performed with both chambers calibrated in air. Both the T34013 and A20 chambers have negligible stem effect. Any x-ray surface brachytherapy system, including Esteya, can be characterized using either one of these calibration protocols and ionization chambers. Having less correction factors, lower uncertainty, and based on measurements, performed in closer to clinical conditions, the TRS-398 protocol seems to be the preferred option.« less

  2. Measuring the Difficult to Measure: Teaching and Learning with an iPad

    ERIC Educational Resources Information Center

    Hargis, Jace; Cavanaugh, Cathy; Kamali, Tayeb; Soto, Melissa

    2013-01-01

    This study applies a comprehensive set of measures to document teaching practice and instructor responses when integrating new mobile technology devices in the classroom. The triangulated measures include a rubric for observing teaching with mobile learning devices in higher education, an interview protocol for capturing faculty levels of mobile…

  3. [Analysis of palliative sedation in hospitalised elderly patients: Effectiveness of a protocol].

    PubMed

    Mateos-Nozal, Jesús; García-Cabrera, Lorena; Montero Errasquín, Beatriz; Cruz-Jentoft, Alfonso José; Rexach Cano, Lourdes

    2016-01-01

    To measure changes in the practice of palliative sedation during agony in hospitalised elderly patients before and after the implementation of a palliative sedation protocol. A retrospective before-after study was performed in hospitalised patients over 65 years old who received midazolam during hospital admission and died in the hospital in two 3-month periods, before and after the implementation of the protocol. Non-sedative uses of midazolam and patients in intensive care were excluded. Patient and admission characteristics, the consent process, withdrawal of life-sustaining treatments, and the sedation process (refractory symptom treated, drug doses, assessment and use of other drugs) were recorded. Association was analysed using the Chi(2) and Student t tests. A total of 143 patients were included, with no significant differences between groups in demographic characteristics or symptoms. Do not resuscitate (DNR) orders were recorded in approximately 70% of the subjects of each group, and informed consent for sedation was recorded in 91% before vs. 84% after the protocol. Induction and maintenance doses of midazolam followed protocol recommendations in 1.3% before vs 10.4% after the protocol was implemented (P=.02) and adequate rescue doses were used in 1.3% vs 11.9% respectively (P=.01). Midazolam doses were significantly lower (9.86mg vs 18.67mg, P<.001) when the protocol was used than when it was not used. Ramsay sedation score was used in 8% vs. 12% and the Palliative Care Team was involved in 35.5% and 16.4% of the cases (P=.008) before and after the protocol, respectively. Use of midazolam slightly improved after the implementation of a hospital protocol on palliative sedation. The percentage of adequate sedations and the general process of sedation were mostly unchanged by the protocol. More education and further assessment is needed to gauge the effect of these measures in the future. Copyright © 2015 SEGG. Published by Elsevier Espana. All rights reserved.

  4. Continuous-variable measurement-device-independent quantum key distribution with virtual photon subtraction

    NASA Astrophysics Data System (ADS)

    Zhao, Yijia; Zhang, Yichen; Xu, Bingjie; Yu, Song; Guo, Hong

    2018-04-01

    The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.

  5. An intelligent case-adjustment algorithm for the automated design of population-based quality auditing protocols.

    PubMed

    Advani, Aneel; Jones, Neil; Shahar, Yuval; Goldstein, Mary K; Musen, Mark A

    2004-01-01

    We develop a method and algorithm for deciding the optimal approach to creating quality-auditing protocols for guideline-based clinical performance measures. An important element of the audit protocol design problem is deciding which guide-line elements to audit. Specifically, the problem is how and when to aggregate individual patient case-specific guideline elements into population-based quality measures. The key statistical issue involved is the trade-off between increased reliability with more general population-based quality measures versus increased validity from individually case-adjusted but more restricted measures done at a greater audit cost. Our intelligent algorithm for auditing protocol design is based on hierarchically modeling incrementally case-adjusted quality constraints. We select quality constraints to measure using an optimization criterion based on statistical generalizability coefficients. We present results of the approach from a deployed decision support system for a hypertension guideline.

  6. Music therapy protocol development to enhance swallowing training for stroke patients with dysphagia.

    PubMed

    Kim, Soo Ji

    2010-01-01

    Considering the devastating condition of dysphagia, it is necessary to provide intensive therapeutic regimen based on interdisciplinary approach. In this aspect, music-enhanced swallowing protocol was developed through a pilot study. Then, the modified protocol from a pilot study was examined with 8 stroke patients in a local hospital. The protocol was designed to improve oral motor control, laryngeal elevation, breathing, and swallowing functions. The dependent variables measured included reflex, respiration, and laryngeal functions using the Frenchay Dysarthria assessment. Results from the initial to the midevaluation showed that pitch in the laryngeal category were statistically significant after 6th sessions. After the 12th session, when the final evaluation was compared with the initial assessment, additional categories revealed statistically significant changes. It is recommended that this study should be replicated with a control group and a larger sample using either FEES or video fluoroscopy for scientific data to further substantiate music therapy outcomes in stroke rehabilitation.

  7. Flow-mediated Dilation: Can New Approaches Provide Greater Mechanistic Insight into Vascular Dysfunction in Preeclampsia and Other Diseases?

    PubMed Central

    Weissgerber, Tracey L.

    2015-01-01

    Endothelial dysfunction is a key feature of preeclampsia, and may contribute to increased cardiovascular disease risk years after pregnancy. Flow-mediated dilation (FMD) is a non-invasive endothelial function test that predicts cardiovascular event risk. New protocols allow researchers to measure three components of the FMD response: FMD, low flow-mediated constriction and the shear stimulus. This review encourages researchers to think beyond “low FMD” by examining how these three components may provide additional insights into the mechanisms and location of vascular dysfunction. The review then examines what FMD studies reveal about vascular dysfunction in preeclampsia, while highlighting opportunities to gain greater mechanistic insight from new protocols. Studies using traditional protocols show that FMD is low in mid-pregnancy prior to preeclampsia, at diagnosis, and for three years post-partum. However, FMD returns to normal by ten years post-partum. Studies using new protocols are needed to gain more mechanistic insight. PMID:25182159

  8. Flow-mediated dilation: can new approaches provide greater mechanistic insight into vascular dysfunction in preeclampsia and other diseases?

    PubMed

    Weissgerber, Tracey L

    2014-11-01

    Endothelial dysfunction is a key feature of preeclampsia and may contribute to increased cardiovascular disease risk years after pregnancy. Flow-mediated dilation (FMD) is a non-invasive endothelial function test that predicts cardiovascular event risk. New protocols allow researchers to measure three components of the FMD response: FMD, low flow-mediated constriction, and shear stimulus. This review encourages researchers to think beyond "low FMD" by examining how these three components may provide additional insights into the mechanisms and location of vascular dysfunction. The review then examines what FMD studies reveal about vascular dysfunction in preeclampsia while highlighting opportunities to gain greater mechanistic insight from new protocols. Studies using traditional protocols show that FMD is low in mid-pregnancy prior to preeclampsia, at diagnosis, and for 3 years post-partum. However, FMD returns to normal by 10 years post-partum. Studies using new protocols are needed to gain more mechanistic insight.

  9. X-ray microtomography-based measurements of meniscal allografts.

    PubMed

    Mickiewicz, P; Binkowski, M; Bursig, H; Wróbel, Z

    2015-05-01

    X-ray microcomputed tomography (XMT) is a technique widely used to image hard and soft tissues. Meniscal allografts as collagen structures can be imaged and analyzed using XMT. The aim of this study was to present an XMT scanning protocol that can be used to obtain the 3D geometry of menisci. It was further applied to compare two methods of meniscal allograft measurement: traditional (based on manual measurement) and novel (based on digital measurement of 3D models of menisci obtained with use of XMT scanner). The XMT-based menisci measurement is a reliable method for assessing the geometry of a meniscal allograft by measuring the basic meniscal dimensions known from traditional protocol. Thirteen dissected menisci were measured according the same principles traditionally applied in a tissue bank. Next, the same specimens were scanned by a laboratory scanner in the XMT Lab. The images were processed to obtain a 3D mesh. 3D models of allograft geometry were then measured using a novel protocol enhanced by computer software. Then, both measurements were compared using statistical tests. The results showed significant differences (P<0.05) between the lengths of the medial and lateral menisci measured in the tissue bank and the XMT Lab. Also, medial meniscal widths were significantly different (P<0.05). Differences in meniscal lengths may result from difficulties in dissected meniscus measurements in tissue banks, and may be related to the elastic structure of the dissected meniscus. Errors may also be caused by the lack of highlighted landmarks on the meniscal surface in this study. The XMT may be a good technique for assessing meniscal dimensions without actually touching the specimen. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  10. Cooling Tower (Evaporative Cooling System) Measurement and Verification Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Boyd, Brian; Stoughton, Kate M.

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with cooling tower efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  11. Outdoor Irrigation Measurement and Verification Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Stoughton, Kate M.; Figueroa, Jorge

    This measurement and verification (M&V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with outdoor irrigation efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M&V plan, and details the procedures to use to determine water savings.

  12. The objective measurement of physical activity and sedentary behaviour in 2-3 year olds and their parents: a cross-sectional feasibility study in the bi-ethnic Born in Bradford cohort.

    PubMed

    Costa, Silvia; Barber, Sally E; Cameron, Noël; Clemes, Stacy A

    2015-11-11

    The reported lower physical activity (PA) levels of British South Asians (SA) are suggested as a key influence in their increased risk of non-communicable diseases compared to their White British peers. Differences in objectively measured PA and sedentary behaviour (SB) between these ethnic groups have been observed during childhood (ages: 8-10 years). However, no information exists on objectively measured PA/SB in younger children, or how early in life differences in these behaviours emerge. Assessing PA/SB in the Born in Bradford (BIB) cohort study provides an opportunity to address such gaps in the literature, but previous studies have found recruiting and retaining SA participants challenging, and the feasibility of using accelerometers with SA children and parents is unknown. This study investigated the feasibility of recruiting and objectively measuring the habitual PA/SB of 2-3 year old SA and White British children and parents from the BIB study. Families were informed about the study during routine BIB assessments. Consenting families were visited at home for anthropometry measurements, interviews, material delivery and collection. Participants (child and parents) were instructed to wear the ActiGraph GT3X+ for 8 days. Descriptive statistics were computed, and ethnic differences tested (Chi-square) for recruitment uptake and compliance. 160 families (30 % SA) provided contact details, and 97 (22 % SA) agreed to enter the study. White British families showed lower refusal and higher intake into the study than SA (p = 0.006). Of 89 children issued with an accelerometer, 34 % complied with the 8-day protocol (significantly less SA; p = 0.015) and 75 % provided enough days (≥ 3) to assess habitual PA/SB (no ethnic differences). Parental rates of compliance with the protocol did not differ between ethnicities. Issues experienced with the protocol and accelerometer use, and successful implementation strategies/procedures are presented. Although greater efforts may be required to recruit SA, those consenting to participate were as likely as White British to provide enough data to assess habitual PA/SB. The issues and successful strategies reported in this feasibility study represent valuable information for planning future studies, and enhance recruitment and compliance with accelerometer protocols in SA and White British toddlers and parents.

  13. A systematic review of risk factors associated with accidental falls, outcome measures and interventions to manage fall risk in non-ambulatory adults.

    PubMed

    Rice, Laura A; Ousley, Cherita; Sosnoff, Jacob J

    2015-01-01

    To systematically review peer-reviewed literature pertaining to risk factors, outcome measures and interventions managing fall risk in non-ambulatory adults. Twenty-one papers were selected for inclusion from databases including PubMed/Medline, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Cochrane Library, Scopus, Consumer Health Complete and Web of Science. Selected studies involved a description of fall related risk factors, outcomes to assess fall risk and intervention studies describing protocols to manage fall risk in non-ambulatory adults. Studies were selected by two reviewers and consultation provided by a third reviewer. The most frequently cited risk factors/characteristics associated with falls included: wheelchair related characteristics, transfer activities, impaired seated balance and environmental factors. The majority of the outcomes were found to evaluate seated postural control. One intervention study was identified describing a protocol targeting specific problems of individual participants. A global fall prevention program was not identified. Several risk factors associated with falls were identified and must be understood by clinicians to better serve their clients. To improve objective assessment, a comprehensive outcome assessment specific to non-ambulatory adults is needed. Finally, additional research is needed to examine the impact of structured protocols to manage fall risk in non-ambulatory adults. Falls are a common health concern for non-ambulatory adults. Risk factors commonly associated with falls include wheelchair related characteristics, transfer activities, impaired seated balance and environmental factors. Limited outcome measures are available to assess fall risk in non-ambulatory adults. Clinicians must be aware of the known risk factors and provide comprehensive education to their clients on the potential for falls. Additional research is needed to develop and evaluate protocols to clinically manage fall risk.

  14. Prospective Evaluation of a Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System in a Hospital Clinical Microbiology Laboratory for Identification of Bacteria and Yeasts: a Bench-by-Bench Study for Assessing the Impact on Time to Identification and Cost-Effectiveness

    PubMed Central

    Tan, K. E.; Ellis, B. C.; Lee, R.; Stamper, P. D.; Zhang, S. X.

    2012-01-01

    Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories. PMID:22855510

  15. Prospective evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry system in a hospital clinical microbiology laboratory for identification of bacteria and yeasts: a bench-by-bench study for assessing the impact on time to identification and cost-effectiveness.

    PubMed

    Tan, K E; Ellis, B C; Lee, R; Stamper, P D; Zhang, S X; Carroll, K C

    2012-10-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories.

  16. Implementation of a protocol proposed by the Brazilian National Health Surveillance Agency for antibiotic use in very low birth weight infants.

    PubMed

    Pinto, Maria Cristina F Guedes; Bueno, Arnaldo C; Vieira, Alan A

    2013-01-01

    To analyze the implementation of a protocol proposed by the Brazilian National Health Surveillance Agency (Agência Nacional de Vigilância Sanitária - ANVISA) to improve sepsis diagnosis in very low birth weight newborns. This was a prospective study that evaluated the implementation of a protocol involving clinical and laboratory criteria (hematologic scoring system of Rodwell and C-reactive protein serial measurements), recommended by ANVISA, to improve the diagnosis of neonatal sepsis in very low birth weight newborns. The study included all patients who were born and remained in the neonatal intensive care unit until discharge or death, and excluded those with congenital diseases. The main outcomes measured in newborns before (2006-2007) and after implementation of the protocol (2008) were the rates of early and late-onset sepsis, use of antibiotics, and mortality. Means were compared by Student's t-test and categorical variables were compared by the chi-squared test; the significance level for all tests was set at 95%. The study included 136 newborns with very low birth weight. There was no difference between groups regarding general clinical characteristics in the studied periods. There was, however, a decrease in the number of diagnoses of probable early-onset sepsis (p<0.001), use of antimicrobial regimens (p<0.001), and overall mortality and infection-related mortality (p=0.009 and p=0.049, respectively). The implementation of the protocol allowed improvement of sepsis diagnosis by reducing the diagnosis of probable early-onset sepsis, thus promoting efficient antimicrobial use in this population. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, Charles Ci Wen; Xu, Feihu; Siopsis, George

    Quantum position verification (QPV) is the art of verifying the geographical location of an untrusted party. It has recently been shown that the widely studied Bennett & Brassard 1984 (BB84) QPV protocol is insecure after the 3 dB loss point assuming local operations and classical communication (LOCC) adversaries. Here in this paper, we propose a time-reversed entanglement swapping QPV protocol (based on measurement-device-independent quantum cryptography) that is highly robust against quantum channel loss. First, assuming ideal qubit sources, we show that the protocol is secure against LOCC adversaries for any quantum channel loss, thereby overcoming the 3 dB loss limit.more » Then, we analyze the security of the protocol in a more practical setting involving weak laser sources and linear optics. Lastly, in this setting, we find that the security only degrades by an additive constant and the protocol is able to verify positions up to 47 dB channel loss.« less

  18. Loss-tolerant quantum secure positioning with weak laser sources

    NASA Astrophysics Data System (ADS)

    Lim, Charles Ci Wen; Xu, Feihu; Siopsis, George; Chitambar, Eric; Evans, Philip G.; Qi, Bing

    2016-09-01

    Quantum position verification (QPV) is the art of verifying the geographical location of an untrusted party. Recently, it has been shown that the widely studied Bennett & Brassard 1984 (BB84) QPV protocol is insecure after the 3 dB loss point assuming local operations and classical communication (LOCC) adversaries. Here, we propose a time-reversed entanglement swapping QPV protocol (based on measurement-device-independent quantum cryptography) that is highly robust against quantum channel loss. First, assuming ideal qubit sources, we show that the protocol is secure against LOCC adversaries for any quantum channel loss, thereby overcoming the 3 dB loss limit. Then, we analyze the security of the protocol in a more practical setting involving weak laser sources and linear optics. In this setting, we find that the security only degrades by an additive constant and the protocol is able to verify positions up to 47 dB channel loss.

  19. Could the Use of Acoustic Reflexes Prior to Administering Distortion Product Otoacoustic Emissions (DPOAEs) Affect the Results of DPOAEs?

    PubMed

    Garrette, Rachel; Jones, Alisha L; Wilson, Martha W

    2018-05-15

    The purpose of this study is to investigate whether acoustic reflex threshold testing before administration of distortion product otoacoustic emissions can affect the results of the distortion product otoacoustic emissions testing using an automated protocol. Fifteen young adults with normal hearing ranging in age from 19 to 25 years participated in the study. All participants had clear external ear canals and normal Jerger Type A tympanograms and had passed a hearing screening. Testing was performed using the Interacoustics Titan acoustic reflex threshold and distortion product otoacoustic emissions protocol. Participants underwent baseline distortion product otoacoustic emissions. A paired-samples t test was conducted for both the right and left ears to assess within-group differences between baseline distortion product otoacoustic emissions and repeated distortion product otoacoustic emissions measures. No significant differences were found in distortion product otoacoustic emission measures following administration of acoustic reflexes. The use of a protocol when using an automated system that includes both acoustic reflexes and distortion product otoacoustic emissions is important. Overall, presentation of acoustic reflexes prior to measuring distortion product otoacoustic emission did not affect distortion product otoacoustic emission results; therefore, test sequence can be modified as needed.

  20. Effects of dynamic head tilts on sensory organization test performance: a comparison between college-age athletes and nonathletes.

    PubMed

    Clark, Sean; Iltis, Peter W

    2008-05-01

    Controlled laboratory study. To compare postural performance measures of athletes with those of nonathletes when completing the standard Sensory Organization Test (SOT) and a modified SOT that included dynamic head tilts (DHT-SOT). Authors of recently published research have suggested that modifications to the SOT protocol (eg, introduction of pitch and roll head tilts) may enhance the test's sensitivity when assessing postural stability in individuals with higher balance capabilities or with well-compensated sensory deficits. Nineteen athletes and 19 nonathletes (group) completed both the SOT and DHT-SOT (protocol). During the SOT, participants stood upright as steadily as possible for 20 seconds during each of 6 different sensory conditions. As a variation of the SOT, the DHT-SOT incorporated active pitch and roll head tilts into the SOT protocol. Four 2-way mixed-model analyses of variance (with protocol as the repeated factor) were performed to determine if the composite equilibrium score or the visual, vestibular, or somatosensory ratio scores differed between the 2 groups across the 2 testing protocols. Significant group-by-protocol interaction effects were present for both the composite equilibrium score and visual ratio. Follow-up simple main-effects analyses indicated that these measures did not differ between groups for the SOT protocol but were significantly different on the DHT-SOT. The addition of dynamic head tilts to the SOT protocol resulted in subtle differences in balance function between athletes and nonathletes. Athletes demonstrated an increased ability to adapt to sensory disruptions during the DHT-SOT. Therapists should consider including active pitch and roll head tilts to the SOT when evaluating individuals with higher balance function or to detect subtle deficits in balance function. Diagnosis, level 3b.

  1. Association between post-game recovery protocols, physical and perceived recovery, and performance in elite Australian Football League players.

    PubMed

    Bahnert, Andrew; Norton, Kevin; Lock, Phillip

    2013-03-01

    To determine the associations between post-game recovery protocols and physical and perceptual recovery, and game performance in Australian Football League players. A longitudinal quasi-experimental study design was used across a season. A full squad of 44 footballers was monitored weekly across a 23-game season. Players were required to choose from a number of recovery modalities available immediately post-game. These included floor stretching, pool stretching, bike active recovery, pool active recovery, cold-water immersion, contrast therapy and use of a compression garment. Perceptual measures of recovery were recorded throughout the week and a test of physical performance was conducted two days post-game. Game performance ratings were also recorded. The associations between the post-game recovery protocols chosen and players' perceived recovery, and physical and game performances were determined by the association rule data-mining strategy. Statistically significant associations were found between a number of post-game recovery protocols and perceptual recovery. In general, players who chose cold-water immersion, floor stretching, no active recovery (neither bike or pool) and the use of a compression garment post-game, had an increased probability of reporting greater perceptual recovery across the following week, relative to all other permutations of recovery protocols chosen. There were no associations found between post-game recovery protocol combinations and physical recovery. No associations were found between the post-game recovery methods and the next game performance. Perceptual recovery among players was enhanced through the selection of specific combinations of recovery protocols post game. However, no links were found between recovery protocols and physical or game performance measures. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Health Worker Compliance with a 'Test And Treat' Malaria Case Management Protocol in Papua New Guinea.

    PubMed

    Pulford, Justin; Smith, Iso; Mueller, Ivo; Siba, Peter M; Hetzel, Manuel W

    2016-01-01

    The Papua New Guinea (PNG) Department of Health introduced a 'test and treat' malaria case management protocol in 2011. This study assesses health worker compliance with the test and treat protocol on a wide range of measures, examines self-reported barriers to health worker compliance as well as health worker attitudes towards the test and treat protocol. Data were collected by cross-sectional survey conducted in randomly selected primary health care facilities in 2012 and repeated in 2014. The combined survey data included passive observation of current or recently febrile patients (N = 771) and interviewer administered questionnaires completed with health workers (N = 265). Across the two surveys, 77.6% of patients were tested for malaria infection by rapid diagnostic test (RDT) or microscopy, 65.6% of confirmed malaria cases were prescribed the correct antimalarials and 15.3% of febrile patients who tested negative for malaria infection were incorrectly prescribed an antimalarial. Overall compliance with a strictly defined test and treat protocol was 62.8%. A reluctance to test current/recently febrile patients for malaria infection by RDT or microscopy in the absence of acute malaria symptoms, reserving recommended antimalarials for confirmed malaria cases only and choosing to clinically diagnose a malaria infection, despite a negative RDT result were the most frequently reported barriers to protocol compliance. Attitudinal support for the test and treat protocol, as assessed by a nine-item measure, improved across time. In conclusion, health worker compliance with the full test and treat malaria protocol requires improvement in PNG and additional health worker support will likely be required to achieve this. The broader evidence base would suggest any such support should be delivered over a longer period of time, be multi-dimensional and multi-modal.

  3. Health Worker Compliance with a ‘Test And Treat’ Malaria Case Management Protocol in Papua New Guinea

    PubMed Central

    Pulford, Justin; Smith, Iso; Mueller, Ivo; Siba, Peter M.; Hetzel, Manuel W.

    2016-01-01

    The Papua New Guinea (PNG) Department of Health introduced a ‘test and treat’ malaria case management protocol in 2011. This study assesses health worker compliance with the test and treat protocol on a wide range of measures, examines self-reported barriers to health worker compliance as well as health worker attitudes towards the test and treat protocol. Data were collected by cross-sectional survey conducted in randomly selected primary health care facilities in 2012 and repeated in 2014. The combined survey data included passive observation of current or recently febrile patients (N = 771) and interviewer administered questionnaires completed with health workers (N = 265). Across the two surveys, 77.6% of patients were tested for malaria infection by rapid diagnostic test (RDT) or microscopy, 65.6% of confirmed malaria cases were prescribed the correct antimalarials and 15.3% of febrile patients who tested negative for malaria infection were incorrectly prescribed an antimalarial. Overall compliance with a strictly defined test and treat protocol was 62.8%. A reluctance to test current/recently febrile patients for malaria infection by RDT or microscopy in the absence of acute malaria symptoms, reserving recommended antimalarials for confirmed malaria cases only and choosing to clinically diagnose a malaria infection, despite a negative RDT result were the most frequently reported barriers to protocol compliance. Attitudinal support for the test and treat protocol, as assessed by a nine-item measure, improved across time. In conclusion, health worker compliance with the full test and treat malaria protocol requires improvement in PNG and additional health worker support will likely be required to achieve this. The broader evidence base would suggest any such support should be delivered over a longer period of time, be multi-dimensional and multi-modal. PMID:27391594

  4. Effects of Adding an Internet-Based Pain Coping Skills Training Protocol to a Standardized Education and Exercise Program for People With Persistent Hip Pain (HOPE Trial): Randomized Controlled Trial Protocol

    PubMed Central

    Rini, Christine; Keefe, Francis; French, Simon; Nelligan, Rachel; Kasza, Jessica; Forbes, Andrew; Dobson, Fiona; Haxby Abbott, J.; Dalwood, Andrew; Vicenzino, Bill; Harris, Anthony; Hinman, Rana S.

    2015-01-01

    Background Persistent hip pain in older people is usually due to hip osteoarthritis (OA), a major cause of pain, disability, and psychological dysfunction. Objective The purpose of this study is to evaluate whether adding an Internet-based pain coping skills training (PCST) protocol to a standardized intervention of education followed by physical therapist–instructed home exercise leads to greater reductions in pain and improvements in function. Design An assessor-, therapist-, and participant-blinded randomized controlled trial will be conducted. Setting The study will be conducted in a community setting. Participants The participants will be 142 people over 50 years of age with self-reported hip pain consistent with hip OA. Intervention Participants will be randomly allocated to: (1) a control group receiving a 24-week standardized intervention comprising an 8-week Internet-based education package followed by 5 individual physical therapy exercise sessions plus home exercises (3 times weekly) or (2) a PCST group receiving an 8-week Internet-based PCST protocol in addition to the control intervention. Measurements Outcomes will be measured at baseline and 8, 24, and 52 weeks, with the primary time point at 24 weeks. Primary outcomes are hip pain on walking and self-reported physical function. Secondary outcomes include health-related quality-of-life, participant-perceived treatment response, self-efficacy for pain management and function, pain coping attempts, pain catastrophizing, and physical activity. Measurements of adherence, adverse events, use of health services, and process measures will be collected at 24 and 52 weeks. Cost-effectiveness will be assessed at 52 weeks. Limitations A self-reported diagnosis of persistent hip pain will be used. Conclusions The findings will help determine whether adding an Internet-based PCST protocol to standardized education and physical therapist–instructed home exercise is more effective than education and exercise alone for persistent hip pain. This study has the potential to guide clinical practice toward innovative modes of psychosocial health care provision. PMID:26023213

  5. Validation of the FAST skating protocol to predict aerobic power in ice hockey players.

    PubMed

    Petrella, Nicholas J; Montelpare, William J; Nystrom, Murray; Plyley, Michael; Faught, Brent E

    2007-08-01

    Few studies have reported a sport-specific protocol to measure the aerobic power of ice hockey players using a predictive process. The purpose of our study was to validate an ice hockey aerobic field test on players of varying ages, abilities, and levels. The Faught Aerobic Skating Test (FAST) uses an on-ice continuous skating protocol on a course measuring 160 feet (48.8 m) using a CD to pace the skater with a beep signal to cross the starting line at each end of the course. The FAST incorporates the principle of increasing workload at measured time intervals during a continuous skating exercise. Step-wise multiple regression modelling was used to determine the estimate of aerobic power. Participants completed a maximal aerobic power test using a modified Bruce incremental treadmill protocol, as well as the on-ice FAST. Normative data were collected on 406 ice hockey players (291 males, 115 females) ranging in age from 9 to 25 y. A regression to predict maximum aerobic power was developed using body mass (kg), height (m), age (y), and maximum completed lengths of the FAST as the significant predictors of skating aerobic power (adjusted R2 = 0.387, SEE = 7.25 mL.kg-1.min-1, p < 0.0001). These results support the application of the FAST in estimating aerobic power among male and female competitive ice hockey players between the ages of 9 and 25 years.

  6. The Decremental Protocol as an Alternative Protocol to Measure Maximal Oxygen Consumption in Athletes.

    PubMed

    Taylor, Katrina; Seegmiller, Jeffrey; Vella, Chantal A

    2016-11-01

    To determine whether a decremental protocol could elicit a higher maximal oxygen consumption (VO 2 max) than an incremental protocol in trained participants. A secondary aim was to examine whether cardiac-output (Q) and stroke-volume (SV) responses differed between decremental and incremental protocols in this sample. Nineteen runners/triathletes were randomized to either the decremental or incremental group. All participants completed an initial incremental VO 2 max test on a treadmill, followed by a verification phase. The incremental group completed 2 further incremental tests. The decremental group completed a second VO 2 max test using the decremental protocol, based on their verification phase. The decremental group then completed a final incremental test. During each test, VO 2 , ventilation, and heart rate were measured, and cardiac variables were estimated with thoracic bioimpedance. Repeated-measures analysis of variance was conducted with an alpha level set at .05. There were no significant main effects for group (P = .37) or interaction (P = .10) over time (P = .45). VO 2 max was similar between the incremental (57.29 ± 8.94 mL · kg -1 · min -1 ) and decremental (60.82 ± 8.49 mL · kg -1 · min -1 ) groups over time. Furthermore, Q and SV were similar between the incremental (Q 22.72 ± 5.85 L/min, SV 119.64 ± 33.02 mL/beat) and decremental groups (Q 20.36 ± 4.59 L/min, SV 109.03 ± 24.27 mL/beat) across all 3 trials. The findings suggest that the decremental protocol does not elicit higher VO 2 max than an incremental protocol but may be used as an alternative protocol to measure VO 2 max in runners and triathletes.

  7. An Accurate Link Correlation Estimator for Improving Wireless Protocol Performance

    PubMed Central

    Zhao, Zhiwei; Xu, Xianghua; Dong, Wei; Bu, Jiajun

    2015-01-01

    Wireless link correlation has shown significant impact on the performance of various sensor network protocols. Many works have been devoted to exploiting link correlation for protocol improvements. However, the effectiveness of these designs heavily relies on the accuracy of link correlation measurement. In this paper, we investigate state-of-the-art link correlation measurement and analyze the limitations of existing works. We then propose a novel lightweight and accurate link correlation estimation (LACE) approach based on the reasoning of link correlation formation. LACE combines both long-term and short-term link behaviors for link correlation estimation. We implement LACE as a stand-alone interface in TinyOS and incorporate it into both routing and flooding protocols. Simulation and testbed results show that LACE: (1) achieves more accurate and lightweight link correlation measurements than the state-of-the-art work; and (2) greatly improves the performance of protocols exploiting link correlation. PMID:25686314

  8. Examination of an interventionist-led HIV intervention among criminal justice-involved female prisoners

    PubMed Central

    Havens, Jennifer R.; Leukefeld, Carl G.; Oser, Carrie B.; Staton-Tindall, Michele; Knudsen, Hannah K.; Mooney, Jennifer; Duvall, Jamieson L.; Clarke, Jennifer G.; Frisman, Linda; Surratt, Hilary L.; Inciardi, James A.

    2009-01-01

    The purpose of this study was to examine the implementation, adherence and protocol fidelity for the Reducing Risky Relationships for HIV (RRR-HIV) study. The RRR-HIV study is a phase III trial of a randomized intervention to reduce human immunodeficiency virus (HIV) risk behaviors among incarcerated women in four US states: Connecticut, Delaware, Kentucky and Rhode Island. The intervention consists of five interventionist-led prison-based group sessions and a sixth individual community-based session. Data on adherence, implementation, acceptability and fidelity of the intervention were obtained from forms completed after the five prison-based sessions by both the interventionist and participant. Data from the sixth session were collected by the interventionist. Of the 363 women recruited to date, 173 (47.6%) have been randomly allocated to the experimental RRR intervention, of which implementation measures were available for 162 (93.6%). Almost three-quarters of women attended all five sessions, each of which lasted a median of 90 minutes, indicating successful implementation of the protocol across multiple study sites. Interventionists and participants alike reported that all of the topics for each session were discussed, suggesting adherence to the protocol. In addition, protocol interventionists indicated that more than 95% of the women were engaged/involved, interested, and understood the materials presented, indicating high levels of acceptability among the participants and fidelity to the intervention protocols. The majority of participants also answered all of the post-test questions correctly, which is another strong indicator of the fidelity to the intervention. Results suggest that the RRR-HIV study has been successfully implemented across multiple study sites. Adherence to the protocol, as well as protocol fidelity and acceptability, were also strong, which is essential to establish prior to examining outcome data. PMID:20090928

  9. Qualification of a precise and easy-to-handle sweat casting imprint method for the prediction and quantification of anti-perspirant efficacy.

    PubMed

    Keyhani, R; Scheede, S; Thielecke, I; Wenck, H; Schmucker, R; Schreiner, V; Ennen, J; Herpens, A

    2009-06-01

    A time- and cost-effective sweat casting method using the forearm as test site to assess the efficacy of several anti-perspirant formulations with a low number of test subjects has been evaluated and qualified. The imprint sweat casting method is based on a 2-component silcone-imprint technique to measure the efficacy of more than eight products in parallel with the same test subject. In studies using aluminum chlorohydrate (ACH) formulations as test anti-perspirants, a clear-cut correlation could be demonstrated between sweat gland activities measured by the imprint method and gravimetric measurement of sweat gland activities. Concentration-dependent inhibition of sweat gland activity could be observed with the imprint technique up to an ACH concentration of 15%, and all formulations containing 2% ACH or above resulted in statistically significant reduction of sweat gland activity (P < 0.001) when compared with untreated control areas. Furthermore, the SDs of individual studies using the imprint technique were in a range of +/-20% of sweat gland activity, which can be regarded rather low for in vivo measurements of a complex process like sweat secretion. A group-wise comparison between the measurements of anti-perspirant activity as determined by the imprint protocol and the Food and Drug Administration (FDA) Guideline compliant gravimetric hot-room protocol revealed that the test results for anti-perspirant activity obtained with the imprint protocol are similar to those obtained with the hot-room protocol. Moreover, the data generated with the imprint protocol have a high predictive value for the outcome of a later guideline-compliant hot-room test. As the imprint casting method tends to be a little more sensitive for formulations with low anti-perspirant activity, and seems to be associated with less interassay variability than the standard gravimetric hot-room test, the imprint casting method may select products which later fail to pass the standard gravimetric hot-room test. Meanwhile the imprint sweat casting has proven to be a robust method useful to support efficacy-oriented product development. Therefore, in later stages of utilization it might even evolve into an efficient claim substantiation tool.

  10. Comparison of microdose flare-up and antagonist multiple-dose protocols for poor-responder patients: a randomized study.

    PubMed

    Demirol, Aygul; Gurgan, Timur

    2009-08-01

    To compare the efficacy of the microdose flare-up and multiple-dose antagonist protocols for poor-responder patients in intracytoplasmic sperm injection-ET cycles. A randomized, prospective study. Center for assisted reproductive technology in Turkey. Ninety patients with poor ovarian response in a minimum of two previous IVF cycles. All women were prospectively randomized into two groups by computer-assisted randomization. The patients in group 1 were stimulated according to the microdose flare-up protocol (n = 45), while the patients in group 2 were stimulated according to antagonist multiple-dose protocol (n = 45). The mean number of mature oocytes retrieved was the primary outcome measure, and fertilization rate, implantation rate per embryo, and clinical pregnancy rates were secondary outcome measures. The mean age of the women, the mean duration of infertility, basal FSH level, and the number of previous IVF cycles were similar in both groups. The total gonadotropin dose used was significantly higher in group 2, while the number of oocytes retrieved was significantly greater in group 1. Although the fertilization and clinical pregnancy rates were nonsignificantly higher in group 1 compared with group 2, the implantation rate was significantly higher in the microdose flare-up group than in the multiple-dose antagonist group (22% vs. 11%). The microdose flare-up protocol seems to have a better outcome in poor-responder patients, with a significantly higher mean number of mature oocytes retrieved and higher implantation rate.

  11. Exertional Tolerance Assessments After Mild Traumatic Brain Injury: A Systematic Review.

    PubMed

    Quatman-Yates, Catherine; Bailes, Anna; Constand, Sara; Sroka, Mary Claire; Nissen, Katharine; Kurowski, Brad; Hugentobler, Jason

    2018-05-01

    To review the literature to identify and summarize strategies for evaluating responses to physical exertion after mild traumatic brain injury (mTBI) for clinical and research purposes. PubMed and EBSCOhost through December 31, 2016. Two independent reviewers selected studies based on the following criteria: (1) inclusion of participants with mTBI/concussion, (2) use of a measurement of physiological or psychosomatic response to exertion, (3) a repeatable description of the exertion protocol was provided, (4) a sample of at least 10 participants with a mean age between 8 and 65 years, and (5) the article was in English. The search process yielded 2685 articles, of which 14 studies met the eligibility requirements. A quality assessment using a checklist was conducted for each study by 2 independent study team members and verified by a third team member. Data were extracted by one team member and verified by a second team member. A qualitative synthesis of the studies revealed that most protocols used a treadmill or cycle ergometer as the exercise modality. Protocol methods varied across studies including differences in initial intensity determination, progression parameters, and exertion duration. Common outcome measures were self-reported symptoms, heart rate, and blood pressure. The strongest evidence indicates that exertional assessments can provide important insight about mTBI recovery and should be administered using symptoms as a guide. Additional studies are needed to verify optimal modes and protocols for post-mTBI exertional assessments. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. Step-up training for colorectal and gastric ESD and the challenge of ESD training in the proximal colon: results from a German Center.

    PubMed

    Ebigbo, Alanna; Probst, Andreas; Römmele, Christoph; Messmann, Helmut

    2018-05-01

    The endoscopic submucosal dissection (ESD) of cancerous and precancerous lesions in the gastrointestinal (GI) tract is an effective but difficult-to-learn procedure, especially for Western endoscopists. We developed a step-up training protocol and evaluated its outcome on a single endoscopist using specific performance measures. The training protocol included a 12-month period of 50 observational and supervised ESD cases as well as 24 animal procedures. After completion of the protocol, ESD competency was evaluated in the first 30 independent ESD cases. Majority of lesions were located in the stomach and rectum. Performance measures included R0-resection rate, complication rate and resection speed. R0 resection rate was 93 %, complication rate was 7 % and median resection speed was 6,77 cm 2 /h. 1 case of delayed perforation with subsequent hemicolectomy occurred in the descending colon. The ESD step-up training protocol used in this study on a single endoscopist showed excellent outcomes for lesions in the rectum and stomach. However, ESD training in the upper colon remains a challenge.

  13. Dose, image quality and spine modeling assessment of biplanar EOS micro-dose radiographs for the follow-up of in-brace adolescent idiopathic scoliosis patients.

    PubMed

    Morel, Baptiste; Moueddeb, Sonia; Blondiaux, Eleonore; Richard, Stephen; Bachy, Manon; Vialle, Raphael; Ducou Le Pointe, Hubert

    2018-05-01

    The aim of this study was to compare the radiation dose, image quality and 3D spine parameter measurements of EOS low-dose and micro-dose protocols for in-brace adolescent idiopathic scoliosis (AIS) patients. We prospectively included 25 consecutive patients (20 females, 5 males) followed for AIS and undergoing brace treatment. The mean age was 12 years (SD 2 years, range 8-15 years). For each patient, in-brace biplanar EOS radiographs were acquired in a standing position using both the conventional low-dose and micro-dose protocols. Dose area product (DAP) was systematically recorded. Diagnostic image quality was qualitatively assessed by two radiologists for visibility of anatomical structures. The reliability of 3D spine modeling between two operators was quantitatively evaluated for the most clinically relevant 3D radiological parameters using intraclass correlation coefficient (ICC). The mean DAP for the posteroanterior and lateral acquisitions was 300 ± 134 and 433 ± 181 mGy cm 2 for the low-dose radiographs, and 41 ± 19 and 81 ± 39 mGy cm 2 for micro-dose radiographs. Image quality was lower with the micro-dose protocol. The agreement was "good" to "very good" for all measured clinical parameters when comparing the low-dose and micro-dose protocols (ICC > 0.73). The micro-dose protocol substantially reduced the delivered dose (by a factor of 5-7 compared to the low-dose protocol) in braced children with AIS. Although image quality was reduced, the micro-dose protocol proved to be adapted to radiological follow-up, with adequate image quality and reliable clinical measurements. These slides can be retrieved under Electronic Supplementary Material.

  14. Application of two segmentation protocols during the processing of virtual images in rapid prototyping: ex vivo study with human dry mandibles.

    PubMed

    Ferraz, Eduardo Gomes; Andrade, Lucio Costa Safira; dos Santos, Aline Rode; Torregrossa, Vinicius Rabelo; Rubira-Bullen, Izabel Regina Fischer; Sarmento, Viviane Almeida

    2013-12-01

    The aim of this study was to evaluate the accuracy of virtual three-dimensional (3D) reconstructions of human dry mandibles, produced from two segmentation protocols ("outline only" and "all-boundary lines"). Twenty virtual three-dimensional (3D) images were built from computed tomography exam (CT) of 10 dry mandibles, in which linear measurements between anatomical landmarks were obtained and compared to an error probability of 5 %. The results showed no statistically significant difference among the dry mandibles and the virtual 3D reconstructions produced from segmentation protocols tested (p = 0,24). During the designing of a virtual 3D reconstruction, both "outline only" and "all-boundary lines" segmentation protocols can be used. Virtual processing of CT images is the most complex stage during the manufacture of the biomodel. Establishing a better protocol during this phase allows the construction of a biomodel with characteristics that are closer to the original anatomical structures. This is essential to ensure a correct preoperative planning and a suitable treatment.

  15. Retinal nerve fiber layer measurements by scanning laser polarimetry with enhanced corneal compensation in healthy subjects.

    PubMed

    Rao, Harsha L; Venkatesh, Chirravuri R; Vidyasagar, Kelli; Yadav, Ravi K; Addepalli, Uday K; Jude, Aarthi; Senthil, Sirisha; Garudadri, Chandra S

    2014-12-01

    To evaluate the (i) effects of biological (age and axial length) and instrument-related [typical scan score (TSS) and corneal birefringence] parameters on the retinal nerve fiber layer (RNFL) measurements and (ii) repeatability of RNFL measurements with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in healthy subjects. In a cross-sectional study, 140 eyes of 73 healthy subjects underwent RNFL imaging with the ECC protocol of SLP. Linear mixed modeling methods were used to evaluate the effects of age, axial length, TSS, and corneal birefringence on RNFL measurements. One randomly selected eye of 48 subjects from the cohort underwent 3 serial scans during the same session to determine the repeatability. Age significantly influenced all RNFL measurements. RNFL measurements decreased by 1 µm for every decade increase in age. TSS affected the overall average RNFL measurement (β=-0.62, P=0.003), whereas residual anterior segment retardance affected the superior quadrant measurement (β=1.14, P=0.01). Axial length and corneal birefringence measurements did not influence RNFL measurements. Repeatability, as assessed by the coefficient of variation, ranged between 1.7% for the overall average RNFL measurement and 11.4% for th nerve fiber indicator. Age significantly affected all RNFL measurements with the ECC protocol of SLP, whereas TSS and residual anterior segment retardance affected the overall average and the superior average RNFL measurements, respectively. Axial length and corneal birefringence measurements did not influence any RNFL measurements. RNFL measurements had good intrasession repeatability. These results are important while evaluating the change in structural measurements over time in glaucoma patients.

  16. Thermal/optical methods for elemental carbon quantification in soils and urban dusts: equivalence of different analysis protocols.

    PubMed

    Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng

    2013-01-01

    Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method.

  17. Color alteration, hydrogen peroxide diffusion, and cytotoxicity caused by in-office bleaching protocols.

    PubMed

    de Almeida, Letícia Cunha Amaral Gonzaga; Soares, Diana Gabriela; Gallinari, Marjorie Oliveira; de Souza Costa, Carlos Alberto; Dos Santos, Paulo Henrique; Briso, André Luiz Fraga

    2015-04-01

    This study evaluated the color alteration, cytotoxicity, and hydrogen peroxide (HP) diffusion associated with different in-office bleaching protocols. Bovine enamel/dentin disks were subjected to three bleaching sessions with 35 % HP (three 15-min applications), 35 % HP (one 45-min application), or 20 % HP (one 45-min application). The control group was not bleached. Before bleaching, the disks were adapted to artificial pulp chambers positioned in compartments containing 1 ml of acetate buffer or medium, so that the dentin remained in contact with these substances. Immediately after bleaching, the HP that diffused through the disks was stabilized by acetate buffer and was quantified (two-way repeated measures ANOVA/Fisher's protected least significant difference (PLSD) test; α = 5 %). Cells of mouse dental papilla cell-23 (MDPC-23) were incubated in this culture media for 1 h, followed by analysis of cellular metabolism (methyl tetrazolium assay) (one-way ANOVA/Tukey test; α = 5 %) and morphology (scanning electron microscopy). The specimen color alteration (ΔE) was analyzed by reflection spectrophotometry (two-way repeated measures ANOVA/Fisher's PLSD test; α = 5 %). All protocols showed equal effectiveness at the end of the treatment. HP diffusion was significantly higher in the groups bleached with 35 % HP. Reapplication of 35 % HP resulted in increased diffusion only in the first session; however, the decrease in cell metabolism was similar for all studied protocols. Despite greater peroxide diffusion in the groups treated with 35 % HP, all protocols showed the same effectiveness and were cytotoxic to MDPC-23 cells. Bleaching protocols using high HP concentrations should be avoided because they exert aggressive actions on odontoblast-like cells.

  18. Optimal single-shot strategies for discrimination of quantum measurements

    NASA Astrophysics Data System (ADS)

    Sedlák, Michal; Ziman, Mário

    2014-11-01

    We study discrimination of m quantum measurements in the scenario when the unknown measurement with n outcomes can be used only once. We show that ancilla-assisted discrimination procedures provide a nontrivial advantage over simple (ancilla-free) schemes for perfect distinguishability and we prove that inevitably m ≤n . We derive necessary and sufficient conditions of perfect distinguishability of general binary measurements. We show that the optimization of the discrimination of projective qubit measurements and their mixtures with white noise is equivalent to the discrimination of specific quantum states. In particular, the optimal protocol for discrimination of projective qubit measurements with fixed failure rate (exploiting maximally entangled test state) is described. While minimum-error discrimination of two projective qubit measurements can be realized without any need of entanglement, we show that discrimination of three projective qubit measurements requires a bipartite probe state. Moreover, when the measurements are not projective, the non-maximally entangled test states can outperform the maximally entangled ones. Finally, we rephrase the unambiguous discrimination of measurements as quantum key distribution protocol.

  19. A slotted access control protocol for metropolitan WDM ring networks

    NASA Astrophysics Data System (ADS)

    Baziana, P. A.; Pountourakis, I. E.

    2009-03-01

    In this study we focus on the serious scalability problems that many access protocols for WDM ring networks introduce due to the use of a dedicated wavelength per access node for either transmission or reception. We propose an efficient slotted MAC protocol suitable for WDM ring metropolitan area networks. The proposed network architecture employs a separate wavelength for control information exchange prior to the data packet transmission. Each access node is equipped with a pair of tunable transceivers for data communication and a pair of fixed tuned transceivers for control information exchange. Also, each access node includes a set of fixed delay lines for synchronization reasons; to keep the data packets, while the control information is processed. An efficient access algorithm is applied to avoid both the data wavelengths and the receiver collisions. In our protocol, each access node is capable of transmitting and receiving over any of the data wavelengths, facing the scalability issues. Two different slot reuse schemes are assumed: the source and the destination stripping schemes. For both schemes, performance measures evaluation is provided via an analytic model. The analytical results are validated by a discrete event simulation model that uses Poisson traffic sources. Simulation results show that the proposed protocol manages efficient bandwidth utilization, especially under high load. Also, comparative simulation results prove that our protocol achieves significant performance improvement as compared with other WDMA protocols which restrict transmission over a dedicated data wavelength. Finally, performance measures evaluation is explored for diverse numbers of buffer size, access nodes and data wavelengths.

  20. Validation of the A&D UM-201 device for office blood pressure measurement according to the European Society of Hypertension International Protocol Revision 2010.

    PubMed

    Fania, Claudio; Albertini, Federica; Palatini, Paolo

    2017-08-01

    The aim of this study was to determine the accuracy of the A&D UM-201 device coupled to several cuffs for different arm sizes for office blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Evaluation was carried out in 33 individuals. The mean age of the individuals was 59.3±13.2 years, systolic BP was 145.4±20.6 mmHg (range: 109-186 mmHg), diastolic BP was 87.3±18.0 mmHg (range: 50-124 mmHg), and arm circumference was 30.4±4.2 cm (range: 23-39 cm). The protocol requirements were followed precisely. The UM-201 monitor passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated systolic BP by 3.0±2.1 mmHg and diastolic BP by 2.6±2.0 mmHg. These data show that the A&D UM-201 device coupled to several cuffs for different ranges of arm circumference fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  1. Validation of the A&D BP UB-542 wrist device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Saladini, Francesca; Benetti, Elisabetta; Fania, Claudio; Palatini, Paolo

    2013-08-01

    The objective of this study was to determine the accuracy of the A&D BP UB-542 wrist device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension (ESH). Device evaluation was carried out in 33 patients. The mean age was 50.9±10.1 years, the mean systolic BP was 141.6±22.8 mmHg (range 92 : 189), the mean diastolic BP was 89.2±11.4 mmHg (range 62 : 120), the mean arm circumference was 28.8±3.2 cm (range 23-35), and the mean wrist circumference was 17.1±1.4 cm (range 14-19.5). The protocol requirements were followed precisely. The device passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated the systolic BP by 1.8±7.2 mmHg and diastolic BP by 1.6±5.7 mmHg. These data show that the A&D BP UB-542 wrist device met the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  2. Organ dose measurements from multiple-detector computed tomography using a commercial dosimetry system and tomographic, physical phantoms

    NASA Astrophysics Data System (ADS)

    Lavoie, Lindsey K.

    The technology of computed tomography (CT) imaging has soared over the last decade with the use of multi-detector CT (MDCT) scanners that are capable of performing studies in a matter of seconds. While the diagnostic information obtained from MDCT imaging is extremely valuable, it is important to ensure that the radiation doses resulting from these studies are at acceptably safe levels. This research project focused on the measurement of organ doses resulting from modern MDCT scanners. A commercially-available dosimetry system was used to measure organ doses. Small dosimeters made of optically-stimulated luminescent (OSL) material were analyzed with a portable OSL reader. Detailed verification of this system was performed. Characteristics studied include energy, scatter, and angular responses; dose linearity, ability to erase the exposed dose and ability to reuse dosimeters multiple times. The results of this verification process were positive. While small correction factors needed to be applied to the dose reported by the OSL reader, these factors were small and expected. Physical, tomographic pediatric and adult phantoms were used to measure organ doses. These phantoms were developed from CT images and are composed of tissue-equivalent materials. Because the adult phantom is comprised of numerous segments, dosimeters were placed in the phantom at several organ locations, and doses to select organs were measured using three clinical protocols: pediatric craniosynostosis, adult brain perfusion and adult cardiac CT angiography (CTA). A wide-beam, 320-slice, volumetric CT scanner and a 64-slice, MDCT scanner were used for organ dose measurements. Doses ranged from 1 to 26 mGy for the pediatric protocol, 1 to 1241 mGy for the brain perfusion protocol, and 2-100 mGy for the cardiac protocol. In most cases, the doses measured on the 64-slice scanner were higher than those on the 320-slice scanner. A methodology to measure organ doses with OSL dosimeters received from CT imaging has been presented. These measurements are especially important in keeping with the ALARA (as low as reasonably achievable) principle. While diagnostic information from CT imaging is valuable and necessary, the dose to patients is always a consideration. This methodology aids in this important task. (Full text of this dissertation may be available via the University of Florida Libraries web site. Please check http://www.uflib.ufl.edu/etd.html)

  3. Combining Quality and Curriculum-Based Measurement: A Suggested Assessment Protocol in Writing

    ERIC Educational Resources Information Center

    Ganzeveld, Paula

    2015-01-01

    Curriculum-Based Measures in writing (CBM-W) assesses a variety of fluency-based components of writing. While support exists for the use of CBM measures in the area of writing, there is a need to conduct further validation studies to investigate the utility of these measures within elementary and secondary classrooms. Since only countable indices…

  4. Chronic idiopathic anal pain. Results of a diagnostic-therapeutic protocol in a colorectal referral unit.

    PubMed

    Armañanzas, Laura; Arroyo, Antonio; Ruiz-Tovar, Jaime; López, Alberto; Santos, Jair; Moya, Pedro; Gómez, María Amparo; Candela, Fernando; Calpena, Rafael

    2015-01-01

    Chronic idiopathic anal pain (CIAP) remains a diagnosis of exclusion. Its study and management still lack a standardized protocol. The aim of this study is to evaluate the results obtained with the diagnostic-therapeutic protocol established in our service. We performed a retrospective study of patients diagnosed with CIAP at the Colorectal Unit of the General University Hospital of Elche, between 2005 and 2011. We evaluated 57 patients with a diagnosis of chronic anal pain for functional anorectal disease (FAD). After the application of our diagnostic protocol, final diagnosis of chronic anal pain (CAP) was achieved in 43 cases (75%), including 22 cases of descending perineum syndrome, 12 of proctalgia fugax, 2 of pudendal neuritis and 7 of coccydynia. In 14 patients exclusion diagnosis of CIAP was established. Among the therapies used on patients with CIAP, biofeedback combined with conservative measures improved symptoms in 43% of the cases. Sacral nerve stimulation was assessed in patients who did not respond to other treatments. Through proper anamnesis, physical examination and complementary tests, a specific diagnosis of the cause of CAP by FAD can be achieved, reducing exclusion diagnosis of CIAP to 25% of cases. Conservative measures combined with biofeedback achieved an improvement in pain in more than 40% of the cases of CIAP in our study. Sacral nerve stimulation can be considered as a treatment option in refractory cases. Copyright © 2013 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Protocolized treatment is associated with decreased organ dysfunction in pediatric severe sepsis

    PubMed Central

    Balamuth, Fran; Weiss, Scott L.; Fitzgerald, Julie C.; Hayes, Katie; Centkowski, Sierra; Chilutti, Marianne; Grundmeier, Robert W.; Lavelle, Jane; Alpern, Elizabeth R.

    2016-01-01

    Objective To determine whether treatment with a protocolized sepsis guideline in the emergency department (ED) was associated with a lower burden of organ dysfunction (OD) by hospital day 2 compared to non-protocolized usual care in pediatric patients with severe sepsis. Design Retrospective cohort study Setting Tertiary care children’s hospital from January 1, 2012–March 31, 2014. Measurements and Main Results Subjects with international consensus defined severe sepsis and pediatric intensive care unit (PICU) admission within 24 hours of ED arrival were included. The exposure was the use of a protocolized ED sepsis guideline. The primary outcome was complete resolution of OD by hospital day 2. One hundred eighty nine subjects were identified during the study period. Of these, 121 (64%) were treated with the protocolized ED guideline and 68 were not. There were no significant differences between the groups in age, sex, race, number of comorbid conditions, ED triage level, or OD on arrival to the ED. Patients treated with protocolized ED care were more likely to be free of OD on hospital day 2 after controlling for sex, comorbid condition, indwelling central venous catheter, PIM-2 score, and timing of antibiotics and intravenous fluids (adjusted OR 4.2, 95% CI 1.7, 10.4). Conclusions Use of a protocolized ED sepsis guideline was independently associated with resolution of OD by hospital day 2 compared to non-protocolized usual care. These data indicate that morbidity outcomes in children can be improved with the use of protocolized care. PMID:27455114

  6. In Vivo MRI Quantification of Individual Muscle and Organ Volumes for Assessment of Anabolic Steroid Growth Effects

    PubMed Central

    Wu, Ed X.; Tang, Haiying; Tong, Christopher; Heymsfield, Steve B.; Vasselli, Joseph R.

    2015-01-01

    This study aimed to develop a quantitative and in vivo magnetic resonance imaging (MRI) approach to investigate the muscle growth effects of anabolic steroids. A protocol of MRI acquisition on a standard clinical 1.5 Tesla scanner and quantitative image analysis was established and employed to measure the individual muscle and organ volumes in the intact and castrated guinea pigs undergoing a 16-week treatment protocol by two well-documented anabolic steroids, testosterone and nandrolone, via implanted silastic capsules. High correlations between the in vivo MRI and postmortem dissection measurements were observed for shoulder muscle complex (R = 0.86), masseter (R=0.79), temporalis (R=0.95), neck muscle complex (R=0.58), prostate gland and seminal vesicles (R=0.98), and testis (R=0.96). Furthermore, the longitudinal MRI measurements yielded adequate sensitivity to detect the restoration of growth to or towards normal in castrated guinea pigs by replacing circulating steroid levels to physiological or slightly higher levels, as expected. These results demonstrated that quantitative MRI using a standard clinical scanner provides accurate and sensitive measurement of individual muscles and organs, and this in vivo MRI protocol in conjunction with the castrated guinea pig model constitutes an effective platform to investigate the longitudinal and cross-sectional growth effects of other potential anabolic steroids. The quantitative MRI protocol developed can also be readily adapted for human studies on most clinical MRI scanner to investigate the anabolic steroid growth effects, or monitor the changes in individual muscle and organ volume and geometry following injury, strength training, neuromuscular disorders, and pharmacological or surgical interventions. PMID:18241900

  7. Natural Language Processing-Enabled and Conventional Data Capture Methods for Input to Electronic Health Records: A Comparative Usability Study.

    PubMed

    Kaufman, David R; Sheehan, Barbara; Stetson, Peter; Bhatt, Ashish R; Field, Adele I; Patel, Chirag; Maisel, James Mark

    2016-10-28

    The process of documentation in electronic health records (EHRs) is known to be time consuming, inefficient, and cumbersome. The use of dictation coupled with manual transcription has become an increasingly common practice. In recent years, natural language processing (NLP)-enabled data capture has become a viable alternative for data entry. It enables the clinician to maintain control of the process and potentially reduce the documentation burden. The question remains how this NLP-enabled workflow will impact EHR usability and whether it can meet the structured data and other EHR requirements while enhancing the user's experience. The objective of this study is evaluate the comparative effectiveness of an NLP-enabled data capture method using dictation and data extraction from transcribed documents (NLP Entry) in terms of documentation time, documentation quality, and usability versus standard EHR keyboard-and-mouse data entry. This formative study investigated the results of using 4 combinations of NLP Entry and Standard Entry methods ("protocols") of EHR data capture. We compared a novel dictation-based protocol using MediSapien NLP (NLP-NLP) for structured data capture against a standard structured data capture protocol (Standard-Standard) as well as 2 novel hybrid protocols (NLP-Standard and Standard-NLP). The 31 participants included neurologists, cardiologists, and nephrologists. Participants generated 4 consultation or admission notes using 4 documentation protocols. We recorded the time on task, documentation quality (using the Physician Documentation Quality Instrument, PDQI-9), and usability of the documentation processes. A total of 118 notes were documented across the 3 subject areas. The NLP-NLP protocol required a median of 5.2 minutes per cardiology note, 7.3 minutes per nephrology note, and 8.5 minutes per neurology note compared with 16.9, 20.7, and 21.2 minutes, respectively, using the Standard-Standard protocol and 13.8, 21.3, and 18.7 minutes using the Standard-NLP protocol (1 of 2 hybrid methods). Using 8 out of 9 characteristics measured by the PDQI-9 instrument, the NLP-NLP protocol received a median quality score sum of 24.5; the Standard-Standard protocol received a median sum of 29; and the Standard-NLP protocol received a median sum of 29.5. The mean total score of the usability measure was 36.7 when the participants used the NLP-NLP protocol compared with 30.3 when they used the Standard-Standard protocol. In this study, the feasibility of an approach to EHR data capture involving the application of NLP to transcribed dictation was demonstrated. This novel dictation-based approach has the potential to reduce the time required for documentation and improve usability while maintaining documentation quality. Future research will evaluate the NLP-based EHR data capture approach in a clinical setting. It is reasonable to assert that EHRs will increasingly use NLP-enabled data entry tools such as MediSapien NLP because they hold promise for enhancing the documentation process and end-user experience. ©David R. Kaufman, Barbara Sheehan, Peter Stetson, Ashish R. Bhatt, Adele I. Field, Chirag Patel, James Mark Maisel. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 28.10.2016.

  8. Bidirectional and Asymmetric Controlled Quantum Information Transmission via Five-qubit Brown State

    NASA Astrophysics Data System (ADS)

    Fang, Sheng-hui; Jiang, Min

    2017-05-01

    We put forward a new protocol of deterministic controlled bidirectional quantum information transmission, using a five-qubit Brown state. That is to say Alice wants to teleport an arbitrary single-qubit state to Bob and Bob wants to remotely prepare a known state for Alice via the control of the supervisor Charlie. In terms of physical implementations, only a CNOT gate, one Bell-state measurement and one qubit measurement are used in our protocol. Compared with previous study for solely bidirectional quantum teleportation and solely bidirectional remote state preparation schemes, our protocol is a kind of hybrid approach of information communication which makes the quantum channel multipurpose, i.e., no matter whether the transmitted state is known or unknown, the state information can be transmitted with each other via a five-qubit Brown state under the control of the third party as a supervisor.

  9. Addressing the potential adverse effects of school-based BMI assessments on children's wellbeing.

    PubMed

    Gibbs, Lisa; O'Connor, Thea; Waters, Elizabeth; Booth, Michael; Walsh, Orla; Green, Julie; Bartlett, Jenny; Swinburn, Boyd

    2008-01-01

    INTRODUCTION. Do child obesity prevention research and intervention measures have the potential to generate adverse concerns about body image by focussing on food, physical activity and body weight? Research findings now demonstrate the emergence of body image concerns in children as young as 5 years. In the context of a large school-community-based child health promotion and obesity prevention study, we aimed to address the potential negative effects of height and weight measures on child wellbeing by developing and implementing an evidence-informed protocol to protect and prevent body image concerns. fun 'n healthy in Moreland! is a cluster randomised controlled trial of a child health promotion and obesity prevention intervention in 23 primary schools in an inner urban area of Melbourne, Australia. Body image considerations were incorporated into the study philosophies, aims, methods, staff training, language, data collection and reporting procedures of this study. This was informed by the published literature, professional body image expertise, pilot testing and implementation in the conduct of baseline data collection and the intervention. This study is the first record of a body image protection protocol being an integral part of the research processes of a child obesity prevention study. Whilst we are yet to measure its impact and outcome, we have developed and tested a protocol based on the evidence and with support from stakeholders in order to minimise the adverse impact of study processes on child body image concerns.

  10. Comparison of Calculation and Experiment Implicates Significant Electrostatic Contributions to the Binding Stability of Barnase and Barstar

    PubMed Central

    Dong, Feng; Vijayakumar, M.; Zhou, Huan-Xiang

    2003-01-01

    The contributions of electrostatic interactions to the binding stability of barnase and barstar were studied by the Poisson-Boltzmann model with three different protocols: a), the dielectric boundary specified as the van der Waals (vdW) surface of the protein along with a protein dielectric constant (ɛp) of 4; b), the dielectric boundary specified as the molecular (i.e., solvent-exclusion (SE)) surface along with ɛp = 4; and c), “SE + ɛp = 20.” The “vdW + ɛp = 4” and “SE + ɛp = 20” protocols predicted an overall electrostatic stabilization whereas the “SE + ɛp = 4” protocol predicted an overall electrostatic destabilization. The “vdW + ɛp = 4” protocol was most consistent with experiment. It quantitatively reproduced the observed effects of 17 mutations neutralizing charged residues lining the binding interface and the measured coupling energies of six charge pairs across the interface and reasonably rationalized the experimental ionic strength and pH dependences of the binding constant. In contrast, the “SE + ɛp = 4” protocol predicted significantly larger coupling energies of charge pairs whereas the “SE + ɛp = 20” protocol did not predict any pH dependence. This study calls for further scrutiny of the different Poisson-Boltzmann protocols and demonstrates potential danger in drawing conclusions on electrostatic contributions based on a particular calculation protocol. PMID:12829463

  11. Neuroimaging paradigms for tonotopic mapping (II): the influence of acquisition protocol.

    PubMed

    Langers, Dave R M; Sanchez-Panchuelo, Rosa M; Francis, Susan T; Krumbholz, Katrin; Hall, Deborah A

    2014-10-15

    Numerous studies on the tonotopic organisation of auditory cortex in humans have employed a wide range of neuroimaging protocols to assess cortical frequency tuning. In the present functional magnetic resonance imaging (fMRI) study, we made a systematic comparison between acquisition protocols with variable levels of interference from acoustic scanner noise. Using sweep stimuli to evoke travelling waves of activation, we measured sound-evoked response signals using sparse, clustered, and continuous imaging protocols that were characterised by inter-scan intervals of 8.8, 2.2, or 0.0 s, respectively. With regard to sensitivity to sound-evoked activation, the sparse and clustered protocols performed similarly, and both detected more activation than the continuous method. Qualitatively, tonotopic maps in activated areas proved highly similar, in the sense that the overall pattern of tonotopic gradients was reproducible across all three protocols. However, quantitatively, we observed substantial reductions in response amplitudes to moderately low stimulus frequencies that coincided with regions of strong energy in the scanner noise spectrum for the clustered and continuous protocols compared to the sparse protocol. At the same time, extreme frequencies became over-represented for these two protocols, and high best frequencies became relatively more abundant. Our results indicate that although all three scanning protocols are suitable to determine the layout of tonotopic fields, an exact quantitative assessment of the representation of various sound frequencies is substantially confounded by the presence of scanner noise. In addition, we noticed anomalous signal dynamics in response to our travelling wave paradigm that suggest that the assessment of frequency-dependent tuning is non-trivially influenced by time-dependent (hemo)dynamics when using sweep stimuli. Copyright © 2014. Published by Elsevier Inc.

  12. Sources of Variation in a Two-Step Monitoring Protocol for Species Clustered in Conspicuous Points: Dolichotis patagonum as a Case Study.

    PubMed

    Alonso Roldán, Virginia; Bossio, Luisina; Galván, David E

    2015-01-01

    In species showing distributions attached to particular features of the landscape or conspicuous signs, counts are commonly made by making focal observations where animals concentrate. However, to obtain density estimates for a given area, independent searching for signs and occupancy rates of suitable sites is needed. In both cases, it is important to estimate detection probability and other possible sources of variation to avoid confounding effects on measurements of abundance variation. Our objective was to assess possible bias and sources of variation in a two-step protocol in which random designs were applied to search for signs while continuously recording video cameras were used to perform abundance counts where animals are concentrated, using mara (Dolichotis patagonum) as a case study. The protocol was successfully applied to maras within the Península Valdés protected area, given that the protocol was logistically suitable, allowed warrens to be found, the associated adults to be counted, and the detection probability to be estimated. Variability was documented in both components of the two-step protocol. These sources of variation should be taken into account when applying this protocol. Warren detectability was approximately 80% with little variation. Factors related to false positive detection were more important than imperfect detection. The detectability for individuals was approximately 90% using the entire day of observations. The shortest sampling period with a similar detection capacity than a day was approximately 10 hours, and during this period, the visiting dynamic did not show trends. For individual mara, the detection capacity of the camera was not significantly different from the observer during fieldwork. The presence of the camera did not affect the visiting behavior of adults to the warren. Application of this protocol will allow monitoring of the near-threatened mara providing a minimum local population size and a baseline for measuring long-term trends.

  13. Quantum Private Comparison Protocol with Linear Optics

    NASA Astrophysics Data System (ADS)

    Luo, Qing-bin; Yang, Guo-wu; She, Kun; Li, Xiaoyu

    2016-12-01

    In this paper, we propose an innovative quantum private comparison(QPC) protocol based on partial Bell-state measurement from the view of linear optics, which enabling two parties to compare the equality of their private information with the help of a semi-honest third party. Partial Bell-state measurement has been realized by using only linear optical elements in experimental measurement-device-independent quantum key distribution(MDI-QKD) schemes, which makes us believe that our protocol can be realized in the near future. The security analysis shows that the participants will not leak their private information.

  14. Turf Conversion Measurement and Verification Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Stoughton, Kate M.; Figueroa, Jorge

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings as a result of water conservation measures (WCMs) in energy performance contracts associated with converting turfgrass or other water-intensive plantings to water-wise and sustainable landscapes. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  15. Field validation of protocols developed to evaluate in-line mastitis detection systems.

    PubMed

    Kamphuis, C; Dela Rue, B T; Eastwood, C R

    2016-02-01

    This paper reports on a field validation of previously developed protocols for evaluating the performance of in-line mastitis-detection systems. The protocols outlined 2 requirements of these systems: (1) to detect cows with clinical mastitis (CM) promptly and accurately to enable timely and appropriate treatment and (2) to identify cows with high somatic cell count (SCC) to manage bulk milk SCC levels. Gold standard measures, evaluation tests, performance measures, and performance targets were proposed. The current study validated the protocols on commercial dairy farms with automated in-line mastitis-detection systems using both electrical conductivity (EC) and SCC sensor systems that both monitor at whole-udder level. The protocol for requirement 1 was applied on 3 commercial farms. For requirement 2, the protocol was applied on 6 farms; 3 of them had low bulk milk SCC (128×10(3) cells/mL) and were the same farms as used for field evaluation of requirement 1. Three farms with high bulk milk SCC (270×10(3) cells/mL) were additionally enrolled. The field evaluation methodology and results were presented at a workshop including representation from 7 international suppliers of in-line mastitis-detection systems. Feedback was sought on the acceptance of standardized performance evaluation protocols and recommended refinements to the protocols. Although the methodology for requirement 1 was relatively labor intensive and required organizational skills over an extended period, no major issues were encountered during the field validation of both protocols. The validation, thus, proved the protocols to be practical. Also, no changes to the data collection process were recommended by the technology supplier representatives. However, 4 recommendations were made to refine the protocols: inclusion of an additional analysis that ignores small (low-density) clot observations in the definition of CM, extension of the time window from 4 to 5 milkings for timely alerts for CM, setting a maximum number of 10 milkings for the time window to detect a CM episode, and presentation of sensitivity for a larger range of false alerts per 1,000 milkings replacing minimum performance targets. The recommended refinements are discussed with suggested changes to the original protocols. The information presented is intended to inform further debate toward achieving international agreement on standard protocols to evaluate performance of in-line mastitis-detection systems. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Heart rate variability indexes as a marker of chronic adaptation in athletes: a systematic review.

    PubMed

    da Silva, Vanessa Pereira; de Oliveira, Natacha Alves; Silveira, Heitor; Mello, Roger Gomes Tavares; Deslandes, Andrea Camaz

    2015-03-01

    Regular exercise promotes functional and structural changes in the central and peripheral mechanisms of the cardiovascular system. Heart rate variability (HRV) measurement provides a sensitive indicator of the autonomic balance. However, because of the diversity of methods and variables used, the results are difficult to compare in the sports sciences. Since the protocol (supine, sitting, or standing position) and measure (time or frequency domain) are not well defined, the aim of this study is to investigate the HRV measures that better indicates the chronic adaptations of physical exercise in athletes. PubMed (MEDLINE), Web of Science, SciELO (Scientific Electronic Library), and Scopus databases were consulted. Original complete articles in English with short-term signals evaluating young and adult athletes, between 17 and 40 years old, with a control group, published up to 2013 were included. Selected 19 of 1369 studies, for a total sample pool of 333 male and female athletes who practice different sports. The main protocols observed were the supine or standing positions in free or controlled breathing conditions. The main statistical results found in this study were the higher mean RR, standard deviation of RR intervals, and high frequency in athletes group. In addition, the analyses of Cohen's effect size showed that factors as modality of sport, protocol used and unit of measure selected could influence this expected results. Our findings indicate that time domain measures are more consistent than frequency domain to describe the chronic cardiovascular autonomic adaptations in athletes. © 2014 Wiley Periodicals, Inc.

  17. Evaluation of counterfactuality in counterfactual communication protocols

    NASA Astrophysics Data System (ADS)

    Arvidsson-Shukur, D. R. M.; Barnes, C. H. W.; Gottfries, A. N. O.

    2017-12-01

    We provide an in-depth investigation of parameter estimation in nested Mach-Zehnder interferometers (NMZIs) using two information measures: the Fisher information and the Shannon mutual information. Protocols for counterfactual communication have, so far, been based on two different definitions of counterfactuality. In particular, some schemes have been based on NMZI devices, and have recently been subject to criticism. We provide a methodology for evaluating the counterfactuality of these protocols, based on an information-theoretical framework. More specifically, we make the assumption that any realistic quantum channel in MZI structures will have some weak uncontrolled interaction. We then use the Fisher information of this interaction to measure counterfactual violations. The measure is used to evaluate the suggested counterfactual communication protocol of H. Salih et al. [Phys. Rev. Lett. 110, 170502 (2013), 10.1103/PhysRevLett.110.170502]. The protocol of D. R. M. Arvidsson-Shukur and C. H. W. Barnes [Phys. Rev. A 94, 062303 (2016), 10.1103/PhysRevA.94.062303], based on a different definition, is evaluated with a probability measure. Our results show that the definition of Arvidsson-Shukur and Barnes is satisfied by their scheme, while that of Salih et al. is only satisfied by perfect quantum channels. For realistic devices the latter protocol does not achieve its objective.

  18. Measurement of fecal elastase improves performance of newborn screening for cystic fibrosis.

    PubMed

    Barben, Juerg; Rueegg, Corina S; Jurca, Maja; Spalinger, Johannes; Kuehni, Claudia E

    2016-05-01

    The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  19. Research standardization tools: pregnancy measures in the PhenX Toolkit.

    PubMed

    Malinowski, Ann Kinga; Ananth, Cande V; Catalano, Patrick; Hines, Erin P; Kirby, Russell S; Klebanoff, Mark A; Mulvihill, John J; Simhan, Hyagriv; Hamilton, Carol M; Hendershot, Tabitha P; Phillips, Michael J; Kilpatrick, Lisa A; Maiese, Deborah R; Ramos, Erin M; Wright, Rosalind J; Dolan, Siobhan M

    2017-09-01

    Only through concerted and well-executed research endeavors can we gain the requisite knowledge to advance pregnancy care and have a positive impact on maternal and newborn health. Yet the heterogeneity inherent in individual studies limits our ability to compare and synthesize study results, thus impeding the capacity to draw meaningful conclusions that can be trusted to inform clinical care. The PhenX Toolkit (http://www.phenxtoolkit.org), supported since 2007 by the National Institutes of Health, is a web-based catalog of standardized protocols for measuring phenotypes and exposures relevant for clinical research. In 2016, a working group of pregnancy experts recommended 15 measures for the PhenX Toolkit that are highly relevant to pregnancy research. The working group followed the established PhenX consensus process to recommend protocols that are broadly validated, well established, nonproprietary, and have a relatively low burden for investigators and participants. The working group considered input from the pregnancy experts and the broader research community and included measures addressing the mode of conception, gestational age, fetal growth assessment, prenatal care, the mode of delivery, gestational diabetes, behavioral and mental health, and environmental exposure biomarkers. These pregnancy measures complement the existing measures for other established domains in the PhenX Toolkit, including reproductive health, anthropometrics, demographic characteristics, and alcohol, tobacco, and other substances. The preceding domains influence a woman's health during pregnancy. For each measure, the PhenX Toolkit includes data dictionaries and data collection worksheets that facilitate incorporation of the protocol into new or existing studies. The measures within the pregnancy domain offer a valuable resource to investigators and clinicians and are well poised to facilitate collaborative pregnancy research with the goal to improve patient care. To achieve this aim, investigators whose work includes the perinatal population are encouraged to utilize the PhenX Toolkit in the design and implementation of their studies, thus potentially reducing heterogeneity in data measures across studies. Such an effort will enhance the overall impact of individual studies, increasing the ability to draw more meaningful conclusions that can then be translated into clinical practice. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. The use of pedometers for monitoring physical activity in children and adolescents: measurement considerations.

    PubMed

    Clemes, Stacy A; Biddle, Stuart J H

    2013-02-01

    Pedometers are increasingly being used to measure physical activity in children and adolescents. This review provides an overview of common measurement issues relating to their use. Studies addressing the following measurement issues in children/adolescents (aged 3-18 years) were included: pedometer validity and reliability, monitoring period, wear time, reactivity, and data treatment and reporting. Pedometer surveillance studies in children/adolescents (aged: 4-18 years) were also included to enable common measurement protocols to be highlighted. In children > 5 years, pedometers provide a valid and reliable, objective measure of ambulatory activity. Further evidence is required on pedometer validity in preschool children. Across all ages, optimal monitoring frames to detect habitual activity have yet to be determined; most surveillance studies use 7 days. It is recommended that standardized wear time criteria are established for different age groups, and that wear times are reported. As activity varies between weekdays and weekend days, researchers interested in habitual activity should include both types of day in surveillance studies. There is conflicting evidence on the presence of reactivity to pedometers. Pedometers are a suitable tool to objectively assess ambulatory activity in children (> 5 years) and adolescents. This review provides recommendations to enhance the standardization of measurement protocols.

  1. Validation of the Beurer BM 44 upper arm blood pressure monitor for home measurement, according to the European Society of Hypertension International Protocol 2002.

    PubMed

    Lüders, Stephan; Krüger, Ralf; Zemmrich, Claudia; Forstner, Klaus; Sturm, Claus-Dieter; Bramlage, Peter

    2012-12-01

    The present study aimed to validate the automated upper arm blood pressure (BP) measuring device BM 44 for home BP monitoring according to the 2002 Protocol of the European Society of Hypertension. The most important new feature of the new device was an integrated 'WHO indicator', which categorizes the patient's individual result within the WHO recommendations for target BP by a coloured scale. Systolic and diastolic BPs were measured sequentially in 35 adult participants (16 men, 19 women) using a standard mercury y-tubed reference sphygmomanometer (two observers) and the BM 44 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. The BM 44 device passed phase 1 of the validation study successfully with a number of absolute differences between device and observers of 5, 10 and 15 mmHg for at least 28 out of 25, 35 out of 35 and 40 out of 40 measurements, respectively. The device also achieved the targets for phases 2.1 and 2.2, with 23 and 26 participants having had at least two of three device-observers differences within 5 mmHg for systolic and diastolic BP, respectively. The Beurer BM 44 upper arm BP monitor has passed the International Protocol requirements, and hence can be recommended for home use in adults. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  2. Preventing falls in older multifocal glasses wearers by providing single-lens distance glasses: the protocol for the VISIBLE randomised controlled trial

    PubMed Central

    Haran, Mark J; Lord, Stephen R; Cameron, Ian D; Ivers, Rebecca Q; Simpson, Judy M; Lee, Bonsan B; Porwal, Mamta; Kwan, Marcella MS; Severino, Connie

    2009-01-01

    Background Recent research has shown that wearing multifocal glasses increases the risk of trips and falls in older people. The aim of this study is to determine whether the provision of single-lens distance glasses to older multifocal glasses wearers, with recommendations for wearing them for walking and outdoor activities, can prevent falls. We will also measure the effect of the intervention on health status, lifestyle activities and fear of falling, as well as the extent of adherence to the program. Methods/Design Approximately 580 older people who are regular wearers of multifocal glasses people will be recruited. Participants will be randomly allocated to either an intervention group (provision of single lens glasses, with counselling and advice about appropriate use) or a control group (usual care). The primary outcome measure will be falls (measured with 13 monthly calendars). Secondary measures will be quality of life, falls efficacy, physical activity levels and adverse events. Discussions The study will determine the impact of providing single-lens glasses, with advice about appropriate use, on preventing falls in older regular wearers of multifocal glasses. This pragmatic intervention, if found to be effective, will guide practitioners with regard to recommending appropriate glasses for minimising the risk of falls in older people. Trial Registration The protocol for this study was registered with the Clinical Trials.gov Protocol Registration System on June 7th 2006 (#350855). PMID:19321012

  3. Discriminatory validity of the Aspects of Wheelchair Mobility Test as demonstrated by a comparison of four wheelchair types designed for use in low-resource areas

    PubMed Central

    Hamm, Elisa; Wee, Joy

    2017-01-01

    Background Comparative effectiveness research on wheelchairs available in low-resource areas is needed to enable effective use of limited funds. Mobility on commonly encountered rolling environments is a key aspect of function. High variation in capacity among wheelchair users can mask changes in mobility because of wheelchair design. A repeated measures protocol in which the participants use one type of wheelchair and then another minimises the impact of individual variation. Objectives The Aspects of Wheelchair Mobility Test (AWMT) was designed to be used in repeated measures studies in low-resource areas. It measures the impact of different wheelchair types on physical performance in commonly encountered rolling environments and provides an opportunity for qualitative and quantitative participant response. This study sought to confirm the ability of the AWMT to discern differences in mobility because of wheelchair design. Method Participants were wheelchair users at a boarding school for students with disabilities in a low-resource area. Each participant completed timed tests on measured tracks on rough and smooth surfaces, in tight spaces and over curbs. Four types of wheelchairs designed for use in low-resource areas were included. Results The protocol demonstrated the ability to discriminate changes in mobility of individuals because of wheelchair type. Conclusion Comparative effectiveness studies with this protocol can enable beneficial change. This is illustrated by design alterations by wheelchair manufacturers in response to results. PMID:28936413

  4. Cynodon dactylon extract as a preventive and curative agent in experimentally induced nephrolithiasis.

    PubMed

    Atmani, F; Sadki, C; Aziz, M; Mimouni, M; Hacht, B

    2009-04-01

    Cynodon dactylon (Poaceae family) decoction was used in the treatment of kidney stones. However, no scientific study was undertaken so far to demonstrate the beneficial effect of the plant. Thus, the aim of the current study is to evaluate the effect of Cynodon aqueous extract as a preventive and curative agent in experimentally induced nephrolithiasis in a rat model. Ethylene glycol (EG) was used in the experiment to induce calcium oxalate (CaOx) deposition into kidneys. In preventive protocol, Cynodon decoction was administered in the same day with EG to evaluate the ability of the extract to prevent crystal deposition. However, in curative protocol, rats were first rendered nephrolithiasic and then the extract was administered to assess the ability of the plant to eliminate the pre-existing crystal deposition. In both protocols, urinary biochemical and other variables were measured during the course of the study. Crystalluria and renal histology were examined as well. The results showed that, in both protocols, all measured variables were similar for both the rat groups. Nevertheless, urinary biochemical analysis was apparently unaffected by the extract except oxalate in preventive protocol, and calcium, sodium, and potassium in curative protocol which were significantly highly excreted in treated rats compared to untreated animals. Crystalluria was characterized mostly by the presence of large quantities of CaOx monohydrate and CaOx dihydrate particles in untreated rats. However, crystalluria was mainly dominated by the presence of CaOx dihydrate particles with reduced size. The most apparent beneficial effect of Cynodon extract was seen in kidney tissues where reduced levels of CaOx deposition have been noticed especially in medullary and papillary sections from treated rats. We concluded that C. dactylon extract has beneficial effect in preventing and eliminating CaOx deposition into kidneys. Such findings provide a scientific explanation for its use in the treatment of kidneys stones.

  5. Determination of mandibular border and functional movement protocols using an electromagnetic articulograph (EMA).

    PubMed

    Fuentes, Ramon; Navarro, Pablo; Curiqueo, Aldo; Ottone, Nicolas E

    2015-01-01

    The electromagnetic articulograph (EMA) is a device that can collect movement data by positioning sensors at multiple points, measuring displacements of the structure in real time, as well as the acoustics and mechanics of speech using a microphone connected to the measurement system. The aim of this study is to describe protocols for the generation, measurement and visualization of mandibular border and functional movements in the three spatial planes (frontal, sagittal and horizontal) using the EMA. The EMA has transmitter coils that determine magnetic fields to collect information about movements from sensors located on different structures (tongue, palate, mouth, incisors, skin, etc.) and in every direction in an area of 300 mm. After measurement with the EMA, the information is transferred to a computer and read with the Visartico software to visualize the recording of the mandibular movements registered by the EMA. The sensors placed in the space between the three axes XYZ are observed, and then the plots created from the mandibular movements included in the corresponding protocol can be visualized, enabling interpretation of these data. Four protocols for the obtaining of images of the opening and closing mandibular movements were defined and developed, as well as border movements in the frontal, sagittal and horizontal planes, managing to accurately reproduce Posselt's diagram and Gothic arch on the latter two axes. Measurements with the EMA will allow more exact data to be collected in relation to the mandibular clinical physiology and morphology, which will permit more accurate diagnoses and application of more precise and adjusted treatments in the future.

  6. Controlled breathing protocols probe human autonomic cardiovascular rhythms

    NASA Technical Reports Server (NTRS)

    Cooke, W. H.; Cox, J. F.; Diedrich, A. M.; Taylor, J. A.; Beightol, L. A.; Ames, J. E. 4th; Hoag, J. B.; Seidel, H.; Eckberg, D. L.

    1998-01-01

    The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.

  7. Recovery of gait after quadriceps muscle fatigue.

    PubMed

    Barbieri, Fabio Augusto; Beretta, Stephannie Spiandor; Pereira, Vinicius A I; Simieli, Lucas; Orcioli-Silva, Diego; dos Santos, Paulo Cezar Rocha; van Dieën, Jaap H; Gobbi, Lilian Teresa Bucken

    2016-01-01

    The aim of this study was to investigate the effect of recovery time after quadriceps muscle fatigue on gait in young adults. Forty young adults (20-40 years old) performed three 8-m gait trials at preferred velocity before and after muscle fatigue, and after 5, 10 and 20min of passive rest. In addition, at each time point, two maximal isometric voluntary contractions were preformed. Muscle fatigue was induced by repeated sit-to-stand transfers until task failure. Spatio-temporal, kinetic and muscle activity parameters, measured in the central stride of each trial, were analyzed. Data were compared between before and after the muscle fatigue protocol and after the recovery periods by one-way repeated measures ANOVA. The voluntary force was decreased after the fatigue protocol (p<0.001) and after 5, 10 and 20min of recovery compared to before the fatigue protocol. Step width (p<0.001) and RMS of biceps femoris (p<0.05) were increased immediately after the fatigue protocol and remained increased after the recovery periods. In addition, stride duration was decreased immediately after the fatigue protocol compared to before and to after 10 and 20min of rest (p<0.001). The anterior-posterior propulsive impulse was also decreased after the fatigue protocol (p<0.001) and remained low after 5, 10 and 20min of rest. We conclude that 20min is not enough to see full recovery of gait after exhaustive quadriceps muscle fatigue. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. NASA Exercise Physiology and Countermeasures Project Overview

    NASA Technical Reports Server (NTRS)

    Loerch, Linda; Ploutz-Snyder, Lori

    2009-01-01

    Efficient exercise countermeasures are necessary to offset or minimize spaceflight-induced deconditioning and to maximize crew performance of mission tasks. These countermeasure protocols should use the fewest crew and vehicle resources. NASA s Exercise Physiology and Countermeasures (ExPC) Project works to identify, collect, interpret, and summarize evidence that results in effective exercise countermeasure protocols which protect crew health and performance during International Space Station (ISS) and future exploration-class missions. The ExPC and NASA s Human Research Program are sponsoring multiple studies to evaluate and improve the efficacy of spaceflight exercise countermeasures. First, the Project will measure maximal aerobic capacity (VO2max) during cycle ergometry before, during, and after ISS missions. Second, the Project is sponsoring an evaluation of a new prototype harness that offers improved comfort and increased loading during treadmill operations. Third, the Functional Tasks Test protocol will map performance of anticipated lunar mission tasks with physiologic systems before and after short and long-duration spaceflight, to target system contributions and the tailoring of exercise protocols to maximize performance. In addition to these studies that are actively enrolling crewmember participants, the ExPC is planning new studies that include an evaluation of a higher-intensity/lower-volume exercise countermeasure protocol aboard the ISS using the Advanced Resistive Exercise Device and second-generation treadmill, studies that evaluate bone loading during spaceflight exercise, and ground-based studies that focus on fitness for duty standards required to complete lunar mission tasks and for which exercise protocols need to protect. Summaries of these current and future studies and strategies will be provided to international colleagues for knowledge sharing and possible collaboration.

  9. Continuous-variable measurement-device-independent quantum key distribution with photon subtraction

    NASA Astrophysics Data System (ADS)

    Ma, Hong-Xin; Huang, Peng; Bai, Dong-Yun; Wang, Shi-Yu; Bao, Wan-Su; Zeng, Gui-Hua

    2018-04-01

    It has been found that non-Gaussian operations can be applied to increase and distill entanglement between Gaussian entangled states. We show the successful use of the non-Gaussian operation, in particular, photon subtraction operation, on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) protocol. The proposed method can be implemented based on existing technologies. Security analysis shows that the photon subtraction operation can remarkably increase the maximal transmission distance of the CV-MDI-QKD protocol, which precisely make up for the shortcoming of the original CV-MDI-QKD protocol, and one-photon subtraction operation has the best performance. Moreover, the proposed protocol provides a feasible method for the experimental implementation of the CV-MDI-QKD protocol.

  10. Efficient multiparty quantum key agreement with collective detection.

    PubMed

    Huang, Wei; Su, Qi; Liu, Bin; He, Yuan-Hang; Fan, Fan; Xu, Bing-Jie

    2017-11-10

    As a burgeoning branch of quantum cryptography, quantum key agreement is a kind of key establishing processes where the security and fairness of the established common key should be guaranteed simultaneously. However, the difficulty on designing a qualified quantum key agreement protocol increases significantly with the increase of the number of the involved participants. Thus far, only few of the existing multiparty quantum key agreement (MQKA) protocols can really achieve security and fairness. Nevertheless, these qualified MQKA protocols are either too inefficient or too impractical. In this paper, an MQKA protocol is proposed with single photons in travelling mode. Since only one eavesdropping detection is needed in the proposed protocol, the qubit efficiency and measurement efficiency of it are higher than those of the existing ones in theory. Compared with the protocols which make use of the entangled states or multi-particle measurements, the proposed protocol is more feasible with the current technologies. Security and fairness analysis shows that the proposed protocol is not only immune to the attacks from external eavesdroppers, but also free from the attacks from internal betrayers.

  11. Fault-tolerant quantum blind signature protocols against collective noise

    NASA Astrophysics Data System (ADS)

    Zhang, Ming-Hui; Li, Hui-Fang

    2016-10-01

    This work proposes two fault-tolerant quantum blind signature protocols based on the entanglement swapping of logical Bell states, which are robust against two kinds of collective noises: the collective-dephasing noise and the collective-rotation noise, respectively. Both of the quantum blind signature protocols are constructed from four-qubit decoherence-free (DF) states, i.e., logical Bell qubits. The initial message is encoded on the logical Bell qubits with logical unitary operations, which will not destroy the anti-noise trait of the logical Bell qubits. Based on the fundamental property of quantum entanglement swapping, the receiver simply performs two Bell-state measurements (rather than four-qubit joint measurements) on the logical Bell qubits to verify the signature, which makes the protocols more convenient in a practical application. Different from the existing quantum signature protocols, our protocols can offer the high fidelity of quantum communication with the employment of logical qubits. Moreover, we hereinafter prove the security of the protocols against some individual eavesdropping attacks, and we show that our protocols have the characteristics of unforgeability, undeniability and blindness.

  12. Measuring Cardiac Autonomic Nervous System (ANS) Activity in Toddlers - Resting and Developmental Challenges.

    PubMed

    Bush, Nicole R; Caron, Zoe K; Blackburn, Katherine S; Alkon, Abbey

    2016-02-25

    The autonomic nervous system (ANS) consists of two branches, the parasympathetic and sympathetic nervous systems, and controls the function of internal organs (e.g., heart rate, respiration, digestion) and responds to everyday and adverse experiences (1). ANS measures in children have been found to be related to behavior problems, emotion regulation, and health (2-7). Therefore, understanding the factors that affect ANS development during early childhood is important. Both branches of the ANS affect young children's cardiovascular responses to stimuli and have been measured noninvasively, via external monitoring equipment, using valid and reliable measures of physiological change (8-11). However, there are few studies of very young children with simultaneous measures of the parasympathetic and sympathetic nervous systems, which limits understanding of the integrated functioning of the two systems. In addition, the majority of existing studies of young children report on infants' resting ANS measures or their reactivity to commonly used mother-child interaction paradigms, and less is known about ANS reactivity to other challenging conditions. We present a study design and standardized protocol for a non-invasive and rapid assessment of cardiac autonomic control in 18 month old children. We describe methods for continuous monitoring of the parasympathetic and sympathetic branches of the ANS under resting and challenge conditions during a home or laboratory visit and provide descriptive findings from our sample of 140 ethnically diverse toddlers using validated equipment and scoring software. Results revealed that this protocol can produce a range of physiological responses to both resting and developmentally challenging conditions, as indicated by changes in heart rate and indices of parasympathetic and sympathetic activity. Individuals demonstrated variability in resting levels, responses to challenges, and challenge reactivity, which provides additional evidence that this protocol is useful for the examination of ANS individual differences for toddlers.

  13. A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation.

    PubMed

    Boubouchairopoulou, N; Kollias, A; Chiu, B; Chen, B; Lagou, S; Anestis, P; Stergiou, G S

    2017-07-01

    A pocket-size cuffless electronic device for self-measurement of blood pressure (BP) has been developed (Freescan, Maisense Inc., Zhubei, Taiwan). The device estimates BP within 10 s using three embedded electrodes and one force sensor that is applied over the radial pulse to evaluate the pulse wave. Before use, basic anthropometric characteristics are recorded on the device, and individualized initial calibration is required based on a standard BP measurement performed using an upper-arm BP monitor. The device performance in providing valid BP readings was evaluated in 313 normotensive and hypertensive adults in three study phases during which the device sensor was upgraded. A formal validation study of a prototype device against mercury sphygmomanometer was performed according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 2013 protocol. The test device succeeded in obtaining a valid BP measurement (three successful readings within up to five attempts) in 55-72% of the participants, which reached 87% with device sensor upgrade. For the validation study, 125 adults were recruited and 85 met the protocol requirements for inclusion. The mean device-observers BP difference was 3.2±6.7 (s.d.) mm Hg for systolic and 2.6±4.6 mm Hg for diastolic BP (criterion 1). The estimated s.d. (inter-subject variability) were 5.83 and 4.17 mm Hg respectively (criterion 2). These data suggest that this prototype cuffless BP monitor provides valid self-measurements in the vast majority of adults, and satisfies the BP measurement accuracy criteria of the ANSI/AAMI/ISO 2013 validation protocol.

  14. Measuring Tissue Perfusion During Pressure Relief Maneuvers: Insights Into Preventing Pressure Ulcers

    PubMed Central

    Makhsous, Mohsen; Priebe, Michael; Bankard, James; Rowles, Diana; Zeigler, Mary; Chen, David; Lin, Fang

    2007-01-01

    Background/Objective: To study the effect on tissue perfusion of relieving interface pressure using standard wheelchair pushups compared with a mechanical automated dynamic pressure relief system. Design: Repeated measures in 2 protocols on 3 groups of subjects. Participants: Twenty individuals with motor-complete paraplegia below T4, 20 with motor-complete tetraplegia, and 20 able-bodied subjects. Methods: Two 1-hour sitting protocols: dynamic protocol, sitting configuration alternated every 10 minutes between a normal sitting configuration and an off-loading configuration; wheelchair pushup protocol, normal sitting configuration with standard wheelchair pushup once every 20 minutes. Main Outcome Measures: Transcutaneous partial pressures of oxygen and carbon dioxide measured from buttock overlying the ischial tuberosity and interface pressure measured at the seat back and buttocks. Perfusion deterioration and recovery times were calculated during changes in interface pressures. Results: In the off-loading configuration, concentrated interface pressure during the normal sitting configuration was significantly diminished, and tissue perfusion was significantly improved. Wheelchair pushups showed complete relief of interface pressure but incomplete recovery of tissue perfusion. Conclusions: Interface pressure analysis does not provide complete information about the effectiveness of pressure relief maneuvers. Measures of tissue perfusion may help establish more effective strategies. Relief achieved by standard wheelchair pushups may not be sufficient to recover tissue perfusion compromised during sitting; alternate maneuvers may be necessary. The dynamic seating system provided effective pressure relief with sustained reduction in interface pressure adequate for complete recovery of tissue perfusion. Differences in perfusion recovery times between subjects with spinal cord injury (SCI) and controls raise questions about the importance of changes in vascular responses to pressure after SCI. PMID:18092567

  15. Poster — Thur Eve — 20: CTDI Measurements using a Radiochromic Film-based clinical protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quintero, C.; Bekerat, H.; DeBlois, F.

    2014-08-15

    The purpose of the study was evaluating accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV-CBCT systems attached to linear accelerators. Energy dependence of Gafchromic XR-QA2 ® film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air-kerma (up to 10 cGy). Calibration curves for each beam quality were created (Film reflectance change Vs. Air-kerma in air). Film responses for same air-kerma values were compared. Film strips were placed into holesmore » of a CTDI phantom and irradiated for several clinical scanning protocols. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured and tabulated CTDIvol values were compared. Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. Measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Results presented a mean variation for the same machine and protocol of 2.6%. Variation of film response is within ±5% resulting in ±15% systematic error in dose estimation if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom, as suggested by TG- 111.« less

  16. Measurement-only verifiable blind quantum computing with quantum input verification

    NASA Astrophysics Data System (ADS)

    Morimae, Tomoyuki

    2016-10-01

    Verifiable blind quantum computing is a secure delegated quantum computing where a client with a limited quantum technology delegates her quantum computing to a server who has a universal quantum computer. The client's privacy is protected (blindness), and the correctness of the computation is verifiable by the client despite her limited quantum technology (verifiability). There are mainly two types of protocols for verifiable blind quantum computing: the protocol where the client has only to generate single-qubit states and the protocol where the client needs only the ability of single-qubit measurements. The latter is called the measurement-only verifiable blind quantum computing. If the input of the client's quantum computing is a quantum state, whose classical efficient description is not known to the client, there was no way for the measurement-only client to verify the correctness of the input. Here we introduce a protocol of measurement-only verifiable blind quantum computing where the correctness of the quantum input is also verifiable.

  17. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol.

    PubMed

    Altunkan, Sekip; Ilman, Nevzat; Altunkan, Erkan

    2007-04-01

    A variety of automatic blood measurement devices with diverse features have been introduced to the medical markets recently. Among these devices, models that measure at the wrist have become increasingly popular in self measurements. The objective of this study was to evaluate the accuracy of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure devices against the mercury sphygmomanometer in adults according to the International Protocol criteria. Fifty-four patients over 30 years of age were studied and classified based on the International Protocol range. Blood pressure measurements at the wrist with the Samsung SBM-100A and Microlife BP 3BU1-5 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential blood pressure measurements were taken. A total of 33 participants with randomly distributed arm circumferences were selected for both of the validation studies. During each validation study, 99 measurements were obtained for comparison from 33 participants. The first phase was performed on 15 participants and if the device passed this phase, 18 more participants were selected. Mean discrepancies and standard deviations of the device-sphygmomanometer were 0.9+/-9.2 and -2.7+/-9.3 mmHg for systolic blood pressure and -1.4+/-8.0 mmHg and 1.4+/-5.7 for diastolic blood pressure in the Samsung and Microlife study groups, respectively. The Samsung SBM-100A passed Phase 1 in 15 participants. Despite the fact that Microlife BP 3BU1-5 passed Phase 1 for diastolic pressure, it failed according to the systolic pressure criteria. Eighteen patients were added and Phase 2 was continued, in which Samsung SBM-100A failed to meet the criteria of Phases 2.1 and 2.2 for adults in systolic and diastolic blood pressure. It was found that the Microlife BP 3BU1-5 does not meet the criteria of either of Phases 2.1 and 2.2 for systolic blood pressure and Phase 2.2 for diastolic blood pressure. In this study, Samsung SBM-100A and Microlife blood pressure 3BU1-5 wrist blood pressure monitoring devices were found to be incompetent to meet the criteria of the International Protocol and it has not been possible to suggest any one of them for clinical use in adults.

  18. The reliability and validity of fatigue measures during short-duration maximal-intensity intermittent cycling.

    PubMed

    Glaister, Mark; Stone, Michael H; Stewart, Andrew M; Hughes, Michael; Moir, Gavin L

    2004-08-01

    The purpose of the present study was to assess the reliability and validity of fatigue measures, as derived from 4 separate formulae, during tests of repeat sprint ability. On separate days over a 3-week period, 2 groups of 7 recreationally active men completed 6 trials of 1 of 2 maximal (20 x 5 seconds) intermittent cycling tests with contrasting recovery periods (10 or 30 seconds). All trials were conducted on a friction-braked cycle ergometer, and fatigue scores were derived from measures of mean power output for each sprint. Apart from formula 1, which calculated fatigue from the percentage difference in mean power output between the first and last sprint, all remaining formulae produced fatigue scores that showed a reasonably good level of test-retest reliability in both intermittent test protocols (intraclass correlation range: 0.78-0.86; 95% likely range of true values: 0.54-0.97). Although between-protocol differences in the magnitude of the fatigue scores suggested good construct validity, within-protocol differences highlighted limitations with each formula. Overall, the results support the use of the percentage decrement score as the most valid and reliable measure of fatigue during brief maximal intermittent work.

  19. Criteria for the Collection of Useful Respirator Performance Data in the Workplace

    PubMed Central

    Janssen, Larry; Zhuang, Ziqing; Shaffer, Ronald

    2016-01-01

    Workplace protection factors (WPFs) are intended to measure the ability of a respiratory protective device (RPD) to reduce contaminant exposure when used in the context of an effective respiratory protection program. In 1992, members of the American Industrial Hygiene Association Respiratory Protection Committee (RPC) published a review of important issues and considerations for measuring respirator performance in the workplace. The RPC recognized that respirator testing in workplaces can have a variety of objectives and endpoints, and that not all workplace measurements are WPFs. That paper addressed concerns in the general categories of 1) study objectives; 2) site selection; 3) subject selection and preparation; 4) sampling and analytical methods; and 5) data analysis. No specific protocol for measuring WPFs was recommended by the RPC, and attempts to reach a U.S. consensus on a WPF protocol since 1992 have not succeeded. Numerous studies have implemented the principles for WPF measurement described in the RPC paper. Modifications to the original recommendations have been made to reflect the current state of the art. This article describes what has been learned in recent years in each of the five categories identified in the 1992 discussion. Because of the wide variety of workplaces and work activities, contaminants and respiratory protective devices, a strict protocol is not appropriate for collecting WPF data. Rather, the minimum requirements for the collection and presentation of meaningful respirator performance data in the workplace are described. Understanding of these principles will permit useful RPD performance data to be generated. PMID:24579751

  20. Assessment of an improved bone washing protocol for deceased donor human bone.

    PubMed

    Eagle, M J; Man, J; Rooney, P; Hogg, P; Kearney, J N

    2015-03-01

    NHSBT Tissue Services issues bone to surgeons in the UK in two formats, fresh-frozen unprocessed bone from living donors and processed bone from deceased donors. Processed bone may be frozen or freeze dried and all processed bone is currently subjected to a washing protocol to remove blood and bone marrow. In this study we have improved the current bone washing protocol for cancellous bone and assessed the success of the protocol by measuring the removal of the bone marrow components: soluble protein, DNA and haemoglobin at each step in the process, and residual components in the bone at the end of the process. The bone washing protocol is a combination of sonication, warm water washes, centrifugation and chemical (ethanol and hydrogen peroxide) treatments. We report that the bone washing protocol is capable of removing up to 99.85 % soluble protein, 99.95 % DNA and 100 % of haemoglobin from bone. The new bone washing protocol does not render any bone cytotoxic as shown by contact cytotoxicity assays. No microbiological cell growth was detected in any of the wash steps. This process is now in use for processed cancellous bone issued by NHSBT.

  1. Cislan-2 extension final document by University of Twente (Netherlands)

    NASA Astrophysics Data System (ADS)

    Niemegeers, Ignas; Baumann, Frank; Beuwer, Wim; Jordense, Marcel; Pras, Aiko; Schutte, Leon; Tracey, Ian

    1992-01-01

    Results of worked performed under the so called Cislan extension contract are presented. The adaptation of the Cislan 2 prototype design to an environment of interconnected Local Area Networks (LAN's) instead of a single 802.5 token ring LAN is considered. In order to extend the network architecture, the Interconnection Function (IF) protocol layer was subdivided into two protocol layers: a new IF layer, and below the Medium Enhancement (ME) protocol layer. Some small enhancements to the distributed bandwidth allocation protocol were developed, which in fact are also applicable to the 'normal' Cislan 2 system. The new services and protocols are described together with some scenarios and requirements for the new internetting Cislan 2 system. How to overcome the degradation of the quality of speech due to packet loss on the LAN subsystem was studied. Experiments were planned in order to measure this speech quality degradation. Simulations were performed of two Cislan subsystems, the bandwidth allocation protocol and the clock synchronization mechanism. Results on both simulations, performed on SUN workstations using QNAP as a simulation tool, are given. Results of the simulations of the clock synchronization mechanism, and results of the simulation of the distributed bandwidth allocation protocol are given.

  2. Development of Uniform Protocol for Alopecia Areata Clinical Trials.

    PubMed

    Solomon, James A

    2015-11-01

    Developing a successful treatment for alopecia areata (AA), clearly has not been at the forefront of the agenda for new drug/device development among the pharmaceutical and medical device industry. The National Alopecia Areata Foundation (NAAF), a patient advocacy group, initiated a plan to facilitate and drive clinical research toward finding safe and efficacious treatments for AA. As such, Alopecia Areata Uniform Protocols for clinical trials to test new treatments for AA were developed. The design of the uniform protocol is to accomplish the development of a plug-and-play template as well as to provide a framework wherein data from studies utilizing the uniform protocol can be compared through consistency of inclusions/exclusions, safety, and outcome assessment measures. A core uniform protocol for use by pharmaceutical companies in testing proof of concept for investigational products to treat AA. The core protocol includes standardized title, informed consent, inclusion/exclusion criteria, disease outcome assessments, and safety assessments. The statistical methodology to assess successful outcomes will also be standardized. The protocol as well as the informed consent form has been approved in concept by Liberty IRB and is ready to present to pharmaceutical companies.

  3. The NAIMS cooperative pilot project: Design, implementation and future directions.

    PubMed

    Oh, Jiwon; Bakshi, Rohit; Calabresi, Peter A; Crainiceanu, Ciprian; Henry, Roland G; Nair, Govind; Papinutto, Nico; Constable, R Todd; Reich, Daniel S; Pelletier, Daniel; Rooney, William; Schwartz, Daniel; Tagge, Ian; Shinohara, Russell T; Simon, Jack H; Sicotte, Nancy L

    2017-10-01

    The North American Imaging in Multiple Sclerosis (NAIMS) Cooperative represents a network of 27 academic centers focused on accelerating the pace of magnetic resonance imaging (MRI) research in multiple sclerosis (MS) through idea exchange and collaboration. Recently, NAIMS completed its first project evaluating the feasibility of implementation and reproducibility of quantitative MRI measures derived from scanning a single MS patient using a high-resolution 3T protocol at seven sites. The results showed the feasibility of utilizing advanced quantitative MRI measures in multicenter studies and demonstrated the importance of careful standardization of scanning protocols, central image processing, and strategies to account for inter-site variability.

  4. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites.

    PubMed

    Widmann, Gerlig; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Al-Ekrish, Asma'a A

    2017-05-01

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. • Ultra-low-dose MDCT protocols allowed more than 90 % reductions in dose. • Decreasing the dose generally increased density and noise. • Effect of IRT on density and noise varies with reconstruction kernel. • Accuracy of low-dose protocols for interpretation of bony anatomy not known. • Effect of low doses on accuracy of computer-aided design models unknown.

  5. Classification of pregnancies of unknown location according to four different hCG-based protocols.

    PubMed

    Fistouris, J; Bergh, C; Strandell, A

    2016-10-01

    How do four protocols based on serial human chorionic gonadotropin (hCG) measurements perform when classifying pregnancies of unknown location (PULs) as low or high risk of being an ectopic pregnancy (EP)? The use of cut-offs in hCG level changes published by NICE, and a logistic regression model, M4, correctly classify more PULs as high risk, compared with two other protocols. A logistic regression model, M4, based on the mean of two consecutive hCG values and the hCG ratio (hCG 48 h/hCG 0 h) that classify PULs into low- and high-risk groups for triage purposes, identifies more EPs than a protocol using the cut-offs between a 13% decline and a 66% rise in hCG levels over 48 h. A retrospective comparative study of four different hCG-based protocols classifying PULs as low or high risk of being an EP was performed at a gynaecological emergency unit over 3 years. We identified 915 women with a PUL. Initial transvaginal ultrasonography (TVS) findings categorised 187 of the PULs as probable intrauterine pregnancies (IUPs) and 16 as probable EPs. The rate of change in hCG levels over 48 h was calculated for each patient and subjected to three different hCG threshold intervals and a logistic regression model for outcome prediction. Each PUL was subsequently dichotomised to either low-risk (i.e. failed PUL/IUP) or high-risk (i.e. EP) classification, which allowed us to compare the diagnostic performance. In 'Protocol A', a PUL was classified as low risk if >13% hCG level decline or >66% hCG level rise was achieved; otherwise, the PUL was classified as high risk of being an EP. 'Protocol B' classified a PUL as low or high risk using cut-offs of 35-50% declining hCG levels and of 53% rising hCG levels. Similarly, 'Protocol C' used hCG level cut-offs published by NICE, 50% for declining hCG levels and 63% for rising hCG levels. Finally, if a logistic regression model 'Protocol M4' calculated a ≥5% risk of the PUL being an EP, it was classified as high risk, and otherwise the PUL was classified as low risk. When the time interval between two hCG measurements failed to meet an exact 48 h, extrapolation and interpolation of hCG values was made, using log linear transformation. Protocols A, B, C and M4 classified 73, 66, 55 and 56% of PULs as low risk. The sensitivity for protocols A, B, C and M4 was 68% (95% confidence interval (CI) 61-75%), 81% (74-86%), 87% (82-92%) and 88% (83-93%), respectively. The specificity was 82% (80-85%), 77% (74-80%), 66% (62-69%) and 67% (63-70%) for protocols A, B, C and M4, respectively. All comparisons of sensitivity and specificity between the protocols were statistically significant except for protocol C versus protocol M4. In protocol C, 87% (66-97%) of misclassified EPs had rising hCG levels, compared with 19% (6-41%) for protocol M4 (P < 0.01). In a secondary analysis excluding probable IUPs and probable EPs, the results for 712 PULs were analysed. The sensitivity subsequently remained stable for all protocols. Protocol M4 reached a 78% (74-81%) specificity, which was significantly higher than 70% (66-74%) for protocol C (P = 0.01) and protocol M4 classified 63% of PULs as low risk compared with 58% for protocol C. The retrospective design of the study is a limitation. The results are derived from a population where laparoscopy played an important role in PUL management and diagnosis of EPs, although it did reflect real clinical practice. Although we tried to adhere to definitions of PUL and final outcomes as in previous studies and a recent consensus statement, potential differences in this regard must be acknowledged. Where the time interval between two serial hCG measurements deviated from 48 h we estimated 48 h hCG values. A logistic regression model, M4, classifies more PULs correctly as low risk in a selected PUL population without probable IUPs and EPs and identifies as many EPs, in comparison with the cut-offs available in the NICE guideline. This advantage for model M4 may result in a reduction of unnecessary follow-up visits, when fewer low-risk PULs are misclassified as high risk. These findings, however, ought to be clarified in a randomised controlled trial. The study was supported by LUA/ALF grant No. 70940. There are no competing interests. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. SU-F-207-16: CT Protocols Optimization Using Model Observer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tseng, H; Fan, J; Kupinski, M

    2015-06-15

    Purpose: To quantitatively evaluate the performance of different CT protocols using task-based measures of image quality. This work studies the task of size and the contrast estimation of different iodine concentration rods inserted in head- and body-sized phantoms using different imaging protocols. These protocols are designed to have the same dose level (CTDIvol) but using different X-ray tube voltage settings (kVp). Methods: Different concentrations of iodine objects inserted in a head size phantom and a body size phantom are imaged on a 64-slice commercial CT scanner. Scanning protocols with various tube voltages (80, 100, and 120 kVp) and current settingsmore » are selected, which output the same absorbed dose level (CTDIvol). Because the phantom design (size of the iodine objects, the air gap between the inserted objects and the phantom) is not ideal for a model observer study, the acquired CT images are used to generate simulation images with four different sizes and five different contracts iodine objects. For each type of the objects, 500 images (100 x 100 pixels) are generated for the observer study. The observer selected in this study is the channelized scanning linear observer which could be applied to estimate the size and the contrast. The figure of merit used is the correct estimation ratio. The mean and the variance are estimated by the shuffle method. Results: The results indicate that the protocols with 100 kVp tube voltage setting provides the best performance for iodine insert size and contrast estimation for both head and body phantom cases. Conclusion: This work presents a practical and robust quantitative approach using channelized scanning linear observer to study contrast and size estimation performance from different CT protocols. Different protocols at same CTDIvol setting could Result in different image quality performance. The relationship between the absorbed dose and the diagnostic image quality is not linear.« less

  7. Improving the quality of child anthropometry: Manual anthropometry in the Body Imaging for Nutritional Assessment Study (BINA)

    PubMed Central

    2017-01-01

    Anthropometric data collected in clinics and surveys are often inaccurate and unreliable due to measurement error. The Body Imaging for Nutritional Assessment Study (BINA) evaluated the ability of 3D imaging to correctly measure stature, head circumference (HC) and arm circumference (MUAC) for children under five years of age. This paper describes the protocol for and the quality of manual anthropometric measurements in BINA, a study conducted in 2016–17 in Atlanta, USA. Quality was evaluated by examining digit preference, biological plausibility of z-scores, z-score standard deviations, and reliability. We calculated z-scores and analyzed plausibility based on the 2006 WHO Child Growth Standards (CGS). For reliability, we calculated intra- and inter-observer Technical Error of Measurement (TEM) and Intraclass Correlation Coefficient (ICC). We found low digit preference; 99.6% of z-scores were biologically plausible, with z-score standard deviations ranging from 0.92 to 1.07. Total TEM was 0.40 for stature, 0.28 for HC, and 0.25 for MUAC in centimeters. ICC ranged from 0.99 to 1.00. The quality of manual measurements in BINA was high and similar to that of the anthropometric data used to develop the WHO CGS. We attributed high quality to vigorous training, motivated and competent field staff, reduction of non-measurement error through the use of technology, and reduction of measurement error through adequate monitoring and supervision. Our anthropometry measurement protocol, which builds on and improves upon the protocol used for the WHO CGS, can be used to improve anthropometric data quality. The discussion illustrates the need to standardize anthropometric data quality assessment, and we conclude that BINA can provide a valuable evaluation of 3D imaging for child anthropometry because there is comparison to gold-standard, manual measurements. PMID:29240796

  8. SU-E-T-67: A Quality Assurance Procedure for VMAT Delivery Technique with Multiple Verification Metric Using TG-119 Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsuta, Y; Kadoya, N; Shimizu, E

    2015-06-15

    Purpose: A successful VMAT plan delivery includes precise modulations of dose rate, gantry rotational and multi-leaf collimator shapes. The purpose of this research is to construct routine QA protocol which focuses on VMAT delivery technique and to obtain a baseline including dose error, fluence distribution and mechanical accuracy during VMAT. Methods: The mock prostate, head and neck (HN) cases supplied from AAPM were used in this study. A VMAT plans were generated in Monaco TPS according to TG-119 protocol. Plans were created using 6 MV and 10 MV photon beams for each case. The phantom based measurement, fluence measurement andmore » log files analysis were performed. The dose measurement was performed using 0.6 cc ion chamber, which located at isocenter. The fluence distribution were acquired using the MapCHECK2 mounted in the MapPHAN. The trajectory log files recorded inner 20 leaf pairs and gantry angle positions at every 0.25 sec interval were exported to in-house software developed by MATLAB and determined those RMS values. Results: The dose difference is expressed as a ratio of the difference between measured and planned doses. The dose difference for 6 MV was 0.91%, for 10 MV was 0.67%. In turn, the fluence distribution using gamma criteria of 2%/2 mm with a 50% minimum dose threshold for 6 MV was 98.8%, for 10 MV was 97.5%, respectively. The RMS values of MLC for 6 MV and 10 MV were 0.32 mm and 0.37 mm, of gantry were 0.33 degree and 0.31 degree. Conclusion: In this study, QA protocol to assess VMAT delivery accuracy is constructed and results acquired in this study are used as a baseline of VMAT delivery performance verification.« less

  9. Use of the 9-item Shared Decision Making Questionnaire (SDM-Q-9 and SDM-Q-Doc) in intervention studies-A systematic review.

    PubMed

    Doherr, Hanna; Christalle, Eva; Kriston, Levente; Härter, Martin; Scholl, Isabelle

    2017-01-01

    The Shared Decision Making Questionnaire (SDM-Q-9 and SDM-Q-Doc) is a 9-item measure of the decisional process in medical encounters from both patients' and physicians' perspectives. It has good acceptance, feasibility, and reliability. This systematic review aimed to 1) evaluate the use of the SDM-Q-9 and SDM-Q-Doc in intervention studies on shared decision making (SDM) in clinical settings, 2) describe how the SDM-Q-9 and SDM-Q-Doc performed regarding sensitivity to change, and 3) assess the methodological quality of studies and study protocols that use the measure. We conducted a systematic review of studies published between 2010 and October 2015 that evaluated interventions to facilitate SDM. The search strategy comprised three databases (EMBASE, PsycINFO, and Medline), reference tracking, citation tracking, and personal knowledge. Two independent reviewers screened titles and abstracts as well as full texts of potentially relevant records. We extracted the data using a pilot tested sheet, and we assessed the methodological quality of included studies using the Quality Assessment Tools from the U.S. National Institute of Health (NIH). Five completed studies and six study protocols fulfilled the inclusion criteria. The measure was used in a variety of health care settings, mainly in Europe, to evaluate several types of interventions. The reported mean sum scores ranged from 42 to 75 on a scale from 0 to 100. In four studies no significant change was detected in the mean-differences between main groups. In the fifth study the difference was small. Quality assessment revealed a high risk of bias in four of the five completed studies, while the study protocols received moderate quality ratings. We found a wide range of areas in which the SDM-Q-9 and SDM-Q-Doc were applied. In the future this review may help researchers decide whether the measure fits their purposes. Furthermore, the review revealed risk of bias in previous trials that used the measure, and may help future trials decrease this risk. More research on the measure's sensitivity to change is strongly suggested.

  10. Examining a New Method to Studying Velopharyngeal Structures in a Child With 22q11.2 Deletion Syndrome.

    PubMed

    Kollara, Lakshmi; Schenck, Graham; Jaskolka, Michael; Perry, Jamie L

    2017-04-14

    To date, no studies have imaged the velopharynx in children with 22q11.2 deletion syndrome (22q11.2 DS) without the use of sedation. Dysmorphology in velopharyngeal structures has been shown to have significant negative implications on speech among these individuals. This single case study was designed to assess the feasibility of a child-friendly magnetic resonance imaging (MRI) scanning protocol in this clinically challenging population and to determine the utility of this MRI protocol for future work in this area. One 6-year-old White girl diagnosed with 22q11.2 DS was imaged using a child-friendly, nonsedated MRI protocol. Quantitative and qualitative measures of the velopharyngeal area and associated structures were evaluated, and comparisons were made to age-matched control subjects with normal velopharyngeal anatomy. MRI data were successfully obtained using the child-friendly scanning protocol in the subject in the present study. Quantitative and qualitative differences of the levator muscle and associated velopharyngeal structures were noted. Using these MRI and structural analyses methods, insights related to muscle morphology can be obtained and considered as part of the research and clinical examination of children with 22q11.2 DS. The imaging protocol described in this study presents an effective means to counteract difficulties in imaging young children.

  11. Use of cardiocerebral resuscitation or AHA/ERC 2005 Guidelines is associated with improved survival from out-of-hospital cardiac arrest: a systematic review and meta-analysis

    PubMed Central

    Salmen, Marcus; Ewy, Gordon A; Sasson, Comilla

    2012-01-01

    Objective To determine whether the use of cardiocerebral resuscitation (CCR) or AHA/ERC 2005 Resuscitation Guidelines improved patient outcomes from out-of-hospital cardiac arrest (OHCA) compared to older guidelines. Design Systematic review and meta-analysis. Data sources MEDLINE, EMBASE, Web of Science and the Cochrane Library databases. We also hand-searched study references and consulted experts. Study selection Design: randomised controlled trials and observational studies. Population OHCA patients, age >17 years. Comparators ‘Control’ protocol versus ‘Study’ protocol. ‘Control’ protocol defined as AHA/ERC 2000 Guidelines for cardiopulmonary resuscitation (CPR). ‘Study’ protocol defined as AHA/ERC 2005 Guidelines for CPR, or a CCR protocol. Outcome Survival to hospital discharge. Quality High-quality or medium-quality studies, as measured by the Newcastle Ottawa Scale using predefined categories. Results Twelve observational studies met inclusion criteria. All the three studies using CCR demonstrated significantly improved survival compared to use of AHA 2000 Guidelines, as did five of the nine studies using AHA/ERC 2005 Guidelines. Pooled data demonstrate that use of a CCR protocol has an unadjusted OR of 2.26 (95% CI 1.64 to 3.12) for survival to hospital discharge among all cardiac arrest patients. Among witnessed ventricular fibrillation/ventricular tachycardia (VF/VT) patients, CCR increased survival by an OR of 2.98 (95% CI 1.92 to 4.62). Studies using AHA/ERC 2005 Guidelines showed an overall trend towards increased survival, but significant heterogeneity existed among these studies. Conclusions We demonstrate an association with improved survival from OHCA when CCR protocols or AHA/ERC 2005 Guidelines are compared to use of older guidelines. In the subgroup of patients with witnessed VF/VT, there was a threefold increase in OHCA survival when CCR was used. CCR appears to be a promising resuscitation protocol for Emergency Medical Services providers in increasing survival from OHCA. Future research will need to be conducted to directly compare AHA/ERC 2010 Guidelines with the CCR approach. PMID:23036985

  12. Towards a new protocol of scoliosis assessments and monitoring in clinical practice: A pilot study.

    PubMed

    Lukovic, Tanja; Cukovic, Sasa; Lukovic, Vanja; Devedzic, Goran; Djordjevic, Dusica

    2015-01-01

    Although intensively investigated, the procedures for assessment and monitoring of scoliosis are still a subject of controversies. The aim of this study was to assess validity and reliability of a number of physiotherapeutic measurements that could be used for clinical monitoring of scoliosis. Fifteen healthy (symmetric) subjects were subjected to a set of measurements two times, by two experienced and two inexperienced physiotherapists. Intra-observer and inter-observer reliability of measurements were determined. Following measurements were performed: body height and weight, chest girth in inspirium and expirium, the length of legs, the spine translation, the lateral pelvic tilt, the equality of the shoulders, position of scapulas, the equality of stature triangles, the rib hump, the existence of m. iliopsoas contracture, Fröhner index, the size of lumbar lordosis and the angle of trunk rotation. Intraclass correlation coefficient was high (> 0.8) for majority of measurements when experienced physiotherapists performed them, while inexperienced physiotherapists performed precisely only basic, easy measurements. We showed in this pilot study on healthy subjects, that majority of basic physiotherapeutic measurements are valid and reliable when performed by specialized physiotherapist, and it can be expected that this protocol will gain high value when measurements on subjects with scoliosis are performed.

  13. Measuring out-of-time-order correlations and multiple quantum spectra in a trapped-ion quantum magnet

    NASA Astrophysics Data System (ADS)

    Gärttner, Martin; Bohnet, Justin G.; Safavi-Naini, Arghavan; Wall, Michael L.; Bollinger, John J.; Rey, Ana Maria

    2017-08-01

    Controllable arrays of ions and ultracold atoms can simulate complex many-body phenomena and may provide insights into unsolved problems in modern science. To this end, experimentally feasible protocols for quantifying the buildup of quantum correlations and coherence are needed, as performing full state tomography does not scale favourably with the number of particles. Here we develop and experimentally demonstrate such a protocol, which uses time reversal of the many-body dynamics to measure out-of-time-order correlation functions (OTOCs) in a long-range Ising spin quantum simulator with more than 100 ions in a Penning trap. By measuring a family of OTOCs as a function of a tunable parameter we obtain fine-grained information about the state of the system encoded in the multiple quantum coherence spectrum, extract the quantum state purity, and demonstrate the buildup of up to 8-body correlations. Future applications of this protocol could enable studies of many-body localization, quantum phase transitions, and tests of the holographic duality between quantum and gravitational systems.

  14. Description and Evaluation of the Research Ethics Review Process in Japan: Proposed Measures for Improvement.

    PubMed

    Suzuki, Mika; Sato, Keiko

    2016-07-01

    Research Ethics Committees (RECs) are designed to protect human subjects in research. It is essential to recognize whether the RECs are achieving this goal. Several studies have reported on RECs; however, detailed data regarding the quality of research protocols and the review process of RECs have not been reported in Japan. We examine research protocols reviewed by RECs and the review processes at three institutions using a novel checklist we developed. The data show that approximately half of all examined protocols lacked a clearly written "Background" section that defines the study rationale and design. These results reiterate suggestions made in previous research regarding educational programs and support departments that could enhance responsible conduct in clinical research to protect human subjects in Japan. © The Author(s) 2016.

  15. Enhancing reproducibility of ultrasonic measurements by new users

    NASA Astrophysics Data System (ADS)

    Pramanik, Manojit; Gupta, Madhumita; Krishnan, Kajoli Banerjee

    2013-03-01

    Perception of operator influences ultrasound image acquisition and processing. Lower costs are attracting new users to medical ultrasound. Anticipating an increase in this trend, we conducted a study to quantify the variability in ultrasonic measurements made by novice users and identify methods to reduce it. We designed a protocol with four presets and trained four new users to scan and manually measure the head circumference of a fetal phantom with an ultrasound scanner. In the first phase, the users followed this protocol in seven distinct sessions. They then received feedback on the quality of the scans from an expert. In the second phase, two of the users repeated the entire protocol aided by visual cues provided to them during scanning. We performed off-line measurements on all the images using a fully automated algorithm capable of measuring the head circumference from fetal phantom images. The ground truth (198.1±1.6 mm) was based on sixteen scans and measurements made by an expert. Our analysis shows that: (1) the inter-observer variability of manual measurements was 5.5 mm, whereas the inter-observer variability of automated measurements was only 0.6 mm in the first phase (2) consistency of image appearance improved and mean manual measurements was 4-5 mm closer to the ground truth in the second phase (3) automated measurements were more precise, accurate and less sensitive to different presets compared to manual measurements in both phases. Our results show that visual aids and automation can bring more reproducibility to ultrasonic measurements made by new users.

  16. Investigation of the Study Characteristics Affecting Clinical Trial Quality Using the Protocol Deviations Leading to Exclusion of Subjects From the Per Protocol Set Data in Studies for New Drug Application: A Retrospective Analysis.

    PubMed

    Kohara, Norihito; Kaneko, Masayuki; Narukawa, Mamoru

    2018-01-01

    The concept of the risk-based approach has been introduced as an effort to secure the quality of clinical trials. In the risk-based approach, identification and evaluation of risk in advance are considered important. For recently completed clinical trials, we investigated the relationship between study characteristics and protocol deviations leading to the exclusion of subjects from Per Protocol Set (PPS) efficacy analysis. New drugs approved in Japan in the fiscal year 2014-2015 were targeted in the research. The reasons for excluding subjects from the PPS efficacy analysis were described in 102 trials out of 492 in the summary of new drug application documents, which was publicly disclosed after the drug's regulatory approval. The author extracted these reasons along with the numbers of the cases and the study characteristics of each clinical trial. Then, the direct comparison, univariate regression analysis, and multivariate regression analysis was carried out based on the exclusion rate. The study characteristics for which exclusion of subjects from the PPS efficacy analysis were frequently observed was multiregional clinical trials in study region; inhalant and external use in administration route; Anti-infective for systemic use; Respiratory system, Dermatologicals, and Nervous system in therapeutic drug under the Anatomical Therapeutic Chemical Classification. In the multivariate regression analysis, the clinical trial variables of inhalant, Respiratory system, or Dermatologicals were selected as study characteristics leading to a higher exclusion rate. The characteristics of the clinical trial that is likely to cause protocol deviations that will affect efficacy analysis were suggested. These studies should be considered for specific attention and priority observation in the trial protocol or its monitoring plan and execution, such as a clear description of inclusion/exclusion criteria in the protocol, development of training materials to site staff, and/or trial subjects as specific risk-alleviating measures.

  17. High-throughput microfluidics to control and measure signaling dynamics in single yeast cells

    PubMed Central

    Hansen, Anders S.; Hao, Nan; O'Shea, Erin K.

    2015-01-01

    Microfluidics coupled to quantitative time-lapse fluorescence microscopy is transforming our ability to control, measure, and understand signaling dynamics in single living cells. Here we describe a pipeline that incorporates multiplexed microfluidic cell culture, automated programmable fluid handling for cell perturbation, quantitative time-lapse microscopy, and computational analysis of time-lapse movies. We illustrate how this setup can be used to control the nuclear localization of the budding yeast transcription factor Msn2. Using this protocol, we generate oscillations of Msn2 localization and measure the dynamic gene expression response of individual genes in single cells. The protocol allows a single researcher to perform up to 20 different experiments in a single day, whilst collecting data for thousands of single cells. Compared to other protocols, the present protocol is relatively easy to adopt and higher-throughput. The protocol can be widely used to control and monitor single-cell signaling dynamics in other signal transduction systems in microorganisms. PMID:26158443

  18. Measurement of DNA damage in rat urinary bladder transitional cells: improved selective harvest of transitional cells and detailed Comet assay protocols.

    PubMed

    Wang, Amy; Robertson, John L; Holladay, Steven D; Tennant, Alan H; Lengi, Andrea J; Ahmed, S Ansar; Huckle, William R; Kligerman, Andrew D

    2007-12-01

    Urinary bladder transitional epithelium is the main site of bladder cancer, and the use of transitional cells to study carcinogenesis/genotoxicity is recommended over the use of whole bladders. Because the transitional epithelium is only a small fraction of the whole bladder, the alkaline single cell gel electrophoresis assay (Comet assay), which requires only a small number of cells per sample, is especially suitable for measuring DNA damage in transitional cells. However, existed procedures of cell collection did not yield transitional cells with a high purity, and pooling of samples was needed for Comet assay. The goal of this study was to develop an optimized protocol to evaluate DNA damage in the urinary bladder transitional epithelium. This was achieved by an enzymatic stripping method (trypsin-EDTA incubation plus gentle scraping) to selectively harvest transitional cells from rat bladders, and the use of the alkaline Comet assay to detect DNA strand breaks, alkaline labile sites, and DNA-protein crosslinks. Step by step procedures are reported here. Cells collected from a single rat bladder were sufficient for multiple Comet assays. With this new protocol, increases in DNA damage were detected in transitional cells after in vitro exposure to the positive control agents, hydrogen peroxide or formaldehyde. Repair of the induced DNA damage occurred within 4h. This indicated the capacity for DNA repair was maintained in the harvested cells. The new protocol provides a simple and inexpensive method to detect various types of DNA damage and to measure DNA damage repair in urinary bladder transitional cells.

  19. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter

    NASA Astrophysics Data System (ADS)

    Salehhon, N.; Hashim, S.; Karim, M. K. A.; Ang, W. C.; Musa, Y.; Bahruddin, N. A.

    2017-05-01

    The increasing use of computed tomography (CT) in clinical practice marks the needs to understand the dose descriptor and dose profile. The purposes of the current study were to determine the CT dose index free-in-air (CTDIair) in 128 slice CT scanner and to evaluate the single scan dose profile (SSDP). Thermoluminescent dosimeters (TLD-100) were used to measure the dose profile of the scanner. There were three sets of CT protocols where the tube potential (kV) setting was manipulated for each protocol while the rest of parameters were kept constant. These protocols were based from routine CT abdominal examinations for male adult abdomen. It was found that the increase of kV settings made the values of CTDIair increased as well. When the kV setting was changed from 80 kV to 120 kV and from 120 kV to 140 kV, the CTDIair values were increased as much as 147.9% and 53.9% respectively. The highest kV setting (140 kV) led to the highest CTDIair value (13.585 mGy). The p-value of less than 0.05 indicated that the results were statistically different. The SSDP showed that when the kV settings were varied, the peak sharpness and height of Gaussian function profiles were affected. The full width at half maximum (FWHM) of dose profiles for all protocols were coincided with the nominal beam width set for the measurements. The findings of the study revealed much information on the characterization and performance of 128 slice CT scanner.

  20. Quantum dialogue by nonselective measurements

    NASA Astrophysics Data System (ADS)

    Nguyen, Ba An

    2018-06-01

    Unlike classical measurements, quantum measurements may be useful even without reading the outcome. Such so called nonselective measurements are exploited in this paper to design a quantum dialogue protocol that allows exchanging secret data without prior key distributions. The relevant data to be exchanged are in terms of the high-dimensional mutually unbiased bases of quantum measurements. Appropriate modes of bidirectional controlling are devised to ensure the protocol security which is asymptotic.

  1. High throughput film dosimetry in homogeneous and heterogeneous media for a small animal irradiator

    PubMed Central

    Wack, L.; Ngwa, W.; Tryggestad, E.; Tsiamas, P.; Berbeco, R.; Ng, S.K.; Hesser, J.

    2013-01-01

    Purpose We have established a high-throughput Gafchromic film dosimetry protocol for narrow kilo-voltage beams in homogeneous and heterogeneous media for small-animal radiotherapy applications. The kV beam characterization is based on extensive Gafchromic film dosimetry data acquired in homogeneous and heterogeneous media. An empirical model is used for parameterization of depth and off-axis dependence of measured data. Methods We have modified previously published methods of film dosimetry to suit the specific tasks of the study. Unlike film protocols used in previous studies, our protocol employs simultaneous multichannel scanning and analysis of up to nine Gafchromic films per scan. A scanner and background correction were implemented to improve accuracy of the measurements. Measurements were taken in homogeneous and inhomogeneous phantoms at 220 kVp and a field size of 5 × 5 mm2. The results were compared against Monte Carlo simulations. Results Dose differences caused by variations in background signal were effectively removed by the corrections applied. Measurements in homogeneous phantoms were used to empirically characterize beam data in homogeneous and heterogeneous media. Film measurements in inhomogeneous phantoms and their empirical parameterization differed by about 2%–3%. The model differed from MC by about 1% (water, lung) to 7% (bone). Good agreement was found for measured and modelled off-axis ratios. Conclusions EBT2 films are a valuable tool for characterization of narrow kV beams, though care must be taken to eliminate disturbances caused by varying background signals. The usefulness of the empirical beam model in interpretation and parameterization of film data was demonstrated. PMID:23510532

  2. MPLEx: a Robust and Universal Protocol for Single-Sample Integrative Proteomic, Metabolomic, and Lipidomic Analyses

    PubMed Central

    Nakayasu, Ernesto S.; Nicora, Carrie D.; Sims, Amy C.; Burnum-Johnson, Kristin E.; Kim, Young-Mo; Kyle, Jennifer E.; Matzke, Melissa M.; Shukla, Anil K.; Chu, Rosalie K.; Schepmoes, Athena A.; Jacobs, Jon M.; Baric, Ralph S.; Webb-Robertson, Bobbie-Jo; Smith, Richard D.

    2016-01-01

    ABSTRACT Integrative multi-omics analyses can empower more effective investigation and complete understanding of complex biological systems. Despite recent advances in a range of omics analyses, multi-omic measurements of the same sample are still challenging and current methods have not been well evaluated in terms of reproducibility and broad applicability. Here we adapted a solvent-based method, widely applied for extracting lipids and metabolites, to add proteomics to mass spectrometry-based multi-omics measurements. The metabolite, protein, and lipid extraction (MPLEx) protocol proved to be robust and applicable to a diverse set of sample types, including cell cultures, microbial communities, and tissues. To illustrate the utility of this protocol, an integrative multi-omics analysis was performed using a lung epithelial cell line infected with Middle East respiratory syndrome coronavirus, which showed the impact of this virus on the host glycolytic pathway and also suggested a role for lipids during infection. The MPLEx method is a simple, fast, and robust protocol that can be applied for integrative multi-omic measurements from diverse sample types (e.g., environmental, in vitro, and clinical). IMPORTANCE In systems biology studies, the integration of multiple omics measurements (i.e., genomics, transcriptomics, proteomics, metabolomics, and lipidomics) has been shown to provide a more complete and informative view of biological pathways. Thus, the prospect of extracting different types of molecules (e.g., DNAs, RNAs, proteins, and metabolites) and performing multiple omics measurements on single samples is very attractive, but such studies are challenging due to the fact that the extraction conditions differ according to the molecule type. Here, we adapted an organic solvent-based extraction method that demonstrated broad applicability and robustness, which enabled comprehensive proteomics, metabolomics, and lipidomics analyses from the same sample. Author Video: An author video summary of this article is available. PMID:27822525

  3. Exploring the effects of galantamine paired with meditation and dream reliving on recalled dreams: Toward an integrated protocol for lucid dream induction and nightmare resolution.

    PubMed

    Sparrow, Gregory; Hurd, Ryan; Carlson, Ralph; Molina, Ana

    2018-06-27

    An experimental home study examined the impact of a pre-sleep protocol for enhancing self-awareness, lucidity, and responsiveness in dreams. It included ingesting the cholinesterase inhibitor galantamine--which is widely reported to increase the frequency of lucid dreaming--prior to engaging in middle-of-the-night meditation and the imaginary reliving of a distressing dream while exercising new responses. Thirty-five participants completed an eight-night study, which included pre- and post-baseline nights and six conditions: waking for 40 min before returning to bed, called Wake-Back-to-Bed (WBTB); Wake-Back-to-Bed plus placebo (WBTB + P); Wake-Back-to-Bed plus galantamine (WBTB + G); meditation and dream reliving (MDR); meditation and dream reliving plus placebo (MDR + P); and meditation and dream reliving plus galantamine (MDR + G). The outcome measures included lucidity, reflectiveness, interactive behavior, role change, constructive action, and fear and threat, as measured by the participants' self-ratings. The results support the use of this protocol in further studies of lucid dream induction and nightmare/trauma resolution. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Anthropometric standardisation and quality control protocols for the construction of new, international, fetal and newborn growth standards: the INTERGROWTH-21st Project.

    PubMed

    Cheikh Ismail, L; Knight, H E; Ohuma, E O; Hoch, L; Chumlea, W C

    2013-09-01

    The primary aim of the INTERGROWTH-21(st) Project is to construct new, prescriptive standards describing optimal fetal and preterm postnatal growth. The anthropometric measurements include the head circumference, recumbent length and weight of the infants, and the stature and weight of the parents. In such a large, international, multicentre project, it is critical that all study sites follow standardised protocols to ensure maximal validity of the growth and nutrition indicators used. This paper describes in detail the anthropometric training, standardisation and quality control procedures used to collect data for these new standards. The initial standardisation session was in Nairobi, Kenya, using newborns, which was followed by similar sessions in the eight participating study sites in Brazil, China, India, Italy, Kenya, Oman, UK and USA. The intraobserver and inter-observer technical error of measurement values for head circumference range from 0.3 to 0.4 cm, and for recumbent length from 0.3 to 0.5 cm. These standardisation protocols implemented at each study site worldwide ensure that the anthropometric data collected are of the highest quality to construct international growth standards. © 2013 Royal College of Obstetricians and Gynaecologists.

  5. Validation of the Andon KD5031 for clinical use and self-measurement according to the European Society of Hypertension International Protocol.

    PubMed

    Wu, Ning; Zhang, Xuezhong; Wang, Wen; Zhang, Hongye

    2016-10-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor Andon KD5031 for home BP monitoring according to the European Society of Hypertension International Protocol revision 2010. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were sequentially measured in 33 participants using the standard mercury sphygmomanometer and the Andon KD5031 device. Ninety-nine pairs of comparisons were obtained from 33 participants for analysis. The KD5031 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and the observers within a range of 5, 10, and 15 mmHg was 66/99, 93/99, and 98/99, respectively, for SBP and 72/99, 94/99, and 99/99, respectively, for DBP. The device also achieved the targets in part 2 of the validation study. Twenty-six participants for both SBP and DBP had at least two of the three device-observer differences within 5 mmHg (required ≥24). The number of participants without a device-observer difference within 5 mmHg was one for SBP and three for DBP (required ≤3). The Andon upper arm BP monitor KD5031 has passed the International Protocol requirements, and it can be recommended for clinical use and self-measurement in adults.

  6. Validation of the Andon KD595 for clinical use and self-measurement according to the European Society of Hypertension International Protocol.

    PubMed

    Wu, Ning; Zhang, Xuezhong; Wang, Wen; Zhang, Hongye

    2016-04-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor Andon KD595 for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were sequentially measured in 33 participants using the standard mercury sphygmomanometer and the Andon KD595 device. Ninety-nine pairs of comparisons were obtained from 33 participants for analysis. The KD595 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and the observers within a range of 5, 10, and 15 mmHg was 72/99, 93/99, and 96/99, respectively, for SBP and 72/99, 96/99, and 99/99, respectively, for DBP. The device also achieved the targets in part 2 of the validation study. A total of 28 and 25 participants had at least two of the three device-observer differences within 5 mmHg (required≥24) for SBP and DBP, respectively. The number of participants without device-observer difference within 5 mmHg was two for SBP and two for DBP (required≤3). The Andon upper arm blood pressure monitor KD595 has passed the International Protocol requirements and it can be recommended for clinical use and self-measurement in adults.

  7. Economic evaluation of an intensive group training protocol compared with usual care physiotherapy in patients with chronic low back pain.

    PubMed

    van der Roer, Nicole; van Tulder, Maurits; van Mechelen, Willem; de Vet, Henrica

    2008-02-15

    Economic evaluation from a societal perspective conducted alongside a randomized controlled trial with a follow-up of 52 weeks. To evaluate the cost effectiveness and cost utility of an intensive group training protocol compared with usual care physiotherapy in patients with nonspecific chronic low back pain. The intensive group training protocol combines exercise therapy, back school, and behavioral principles. Two studies found a significant reduction in absenteeism for a graded activity program in occupational health care. This program has not yet been evaluated in a primary care physiotherapy setting. Participating physical therapists in primary care recruited 114 patients with chronic nonspecific low back pain. Eligible patients were randomized to either the protocol group or the guideline group. Outcome measures included functional status (Roland Morris Disability Questionnaire), pain intensity (11-point numerical rating scale), general perceived effect and quality of life (EuroQol-5D). Cost data were measured with cost diaries and included direct and indirect costs related to low back pain. After 52 weeks, the direct health care costs were significantly higher for patients in the protocol group, largely due to the costs of the intervention. The mean difference in total costs amounted to [Euro sign] 233 (95% confidence interval: [Euro sign] -2.185; [Euro sign] 2.764). The cost-effectiveness planes indicated no significant differences in cost effectiveness between the 2 groups. The results of this economic evaluation showed no difference in total costs between the protocol group and the guideline group. The differences in effects were small and not statistically significant. At present, national implementation of the protocol is not recommended.

  8. Crowdsourcing Science to Promote Human Health: New Tools to Promote Sampling of Mosquito Populations by Citizen Scientists

    NASA Astrophysics Data System (ADS)

    Boger, R. A.; Low, R.; Jaroensutasinee, M.; Jaroensutasinee, K.; Sparrow, E. B.; Costosa, J. I.; Medina, J.; Randolph, G.

    2015-12-01

    GLOBE in Thailand and GLOBE in Africa independently developed citizen science protocols for collecting and analyzing mosquito larvae. These protocols have been piloted in several workshops and implemented in schools. Data collected have been used for several secondary, undergraduate and graduate student research studies. Over this past year, 2015, these protocols have been synthesized into one protocol that will be made available to the world-wide community through the GLOBE website (www.globe.gov). This new protocol is designed to be flexible in the mosquito species that can be collected and the types of environments sampled (e.g., containers in and around the house, ponds, irrigation ditches in a rice paddy field). Plans are underway to enable web-based data entry and mobile apps for data collection and submission. Once everything is finalized, a GLOBE field campaign will be initiated for citizen scientists to collect meaningful data on where different types of mosquito larvae are found and how the abundance and distribution is changing seasonally. To assist in the standardization of data collection and quality control, training slides are being developed and will be made available in early 2016. This will enable a wider participation of citizen scientists to participate in this effort to collect mosquito data by making it easier to become part of the GLOBE community. As with mosquito larvae, training slides are being created for hydrosphere, biosphere, atmosphere, and pedosphere GLOBE measurement protocols. The development of the mosquito protocol and the training slides are in direct response to the GLOBE community's desire to increase citizen science participation beyond primary and secondary schools, in observing and measuring environmental change.

  9. Natural Language Processing–Enabled and Conventional Data Capture Methods for Input to Electronic Health Records: A Comparative Usability Study

    PubMed Central

    Sheehan, Barbara; Stetson, Peter; Bhatt, Ashish R; Field, Adele I; Patel, Chirag; Maisel, James Mark

    2016-01-01

    Background The process of documentation in electronic health records (EHRs) is known to be time consuming, inefficient, and cumbersome. The use of dictation coupled with manual transcription has become an increasingly common practice. In recent years, natural language processing (NLP)–enabled data capture has become a viable alternative for data entry. It enables the clinician to maintain control of the process and potentially reduce the documentation burden. The question remains how this NLP-enabled workflow will impact EHR usability and whether it can meet the structured data and other EHR requirements while enhancing the user’s experience. Objective The objective of this study is evaluate the comparative effectiveness of an NLP-enabled data capture method using dictation and data extraction from transcribed documents (NLP Entry) in terms of documentation time, documentation quality, and usability versus standard EHR keyboard-and-mouse data entry. Methods This formative study investigated the results of using 4 combinations of NLP Entry and Standard Entry methods (“protocols”) of EHR data capture. We compared a novel dictation-based protocol using MediSapien NLP (NLP-NLP) for structured data capture against a standard structured data capture protocol (Standard-Standard) as well as 2 novel hybrid protocols (NLP-Standard and Standard-NLP). The 31 participants included neurologists, cardiologists, and nephrologists. Participants generated 4 consultation or admission notes using 4 documentation protocols. We recorded the time on task, documentation quality (using the Physician Documentation Quality Instrument, PDQI-9), and usability of the documentation processes. Results A total of 118 notes were documented across the 3 subject areas. The NLP-NLP protocol required a median of 5.2 minutes per cardiology note, 7.3 minutes per nephrology note, and 8.5 minutes per neurology note compared with 16.9, 20.7, and 21.2 minutes, respectively, using the Standard-Standard protocol and 13.8, 21.3, and 18.7 minutes using the Standard-NLP protocol (1 of 2 hybrid methods). Using 8 out of 9 characteristics measured by the PDQI-9 instrument, the NLP-NLP protocol received a median quality score sum of 24.5; the Standard-Standard protocol received a median sum of 29; and the Standard-NLP protocol received a median sum of 29.5. The mean total score of the usability measure was 36.7 when the participants used the NLP-NLP protocol compared with 30.3 when they used the Standard-Standard protocol. Conclusions In this study, the feasibility of an approach to EHR data capture involving the application of NLP to transcribed dictation was demonstrated. This novel dictation-based approach has the potential to reduce the time required for documentation and improve usability while maintaining documentation quality. Future research will evaluate the NLP-based EHR data capture approach in a clinical setting. It is reasonable to assert that EHRs will increasingly use NLP-enabled data entry tools such as MediSapien NLP because they hold promise for enhancing the documentation process and end-user experience. PMID:27793791

  10. The Effects of Alternative Resuscitation Strategies on Acute Kidney Injury in Patients with Septic Shock.

    PubMed

    Kellum, John A; Chawla, Lakhmir S; Keener, Christopher; Singbartl, Kai; Palevsky, Paul M; Pike, Francis L; Yealy, Donald M; Huang, David T; Angus, Derek C

    2016-02-01

    Septic shock is a common cause of acute kidney injury (AKI), and fluid resuscitation is a major part of therapy. To determine if structured resuscitation designed to alter fluid, blood, and vasopressor use affects the development or severity of AKI or outcomes. Ancillary study to the ProCESS (Protocolized Care for Early Septic Shock) trial of alternative resuscitation strategies (two protocols vs. usual care) for septic shock. We studied 1,243 patients and classified AKI using serum creatinine and urine output. We determined recovery status at hospital discharge, examined rates of renal replacement therapy and fluid overload, and measured biomarkers of kidney damage. Among patients without evidence of AKI at enrollment, 37.6% of protocolized care and 38.1% of usual care patients developed kidney injury (P = 0.90). AKI duration (P = 0.59) and rates of renal replacement therapy did not differ between study arms (6.9% for protocolized care and 4.3% for usual care; P = 0.08). Fluid overload occurred in 8.3% of protocolized care and 6.3% of usual care patients (P = 0.26). Among patients with severe AKI, complete and partial recovery was 50.7 and 13.2% for protocolized patients and 49.1 and 13.4% for usual care patients (P = 0.93). Sixty-day hospital mortality was 6.2% for patients without AKI, 16.8% for those with stage 1, and 27.7% for stages 2 to 3. In patients with septic shock, AKI is common and associated with adverse outcomes, but it is not influenced by protocolized resuscitation compared with usual care.

  11. Feasibility of dietary assessment methods, other tools and procedures for a pan-European food consumption survey among infants, toddlers and children.

    PubMed

    Ocké, Marga; Brants, Henny; Dofkova, Marcela; Freisling, Heinz; van Rossum, Caroline; Ruprich, Jiri; Slimani, Nadia; Temme, Elisabeth; Trolle, Ellen; Vandevijvere, Stefanie; Huybrechts, Inge; de Boer, Evelien

    2015-08-01

    To test the feasibility of tools and procedures for a pan-European food consumption survey among children 0-10 years and to recommend one of two tested dietary assessment methods. Two pilot studies including 378 children were conducted in Belgium and the Czech Republic in the Pilot studies for Assessment of Nutrient intake and food Consumption among Kids in Europe. One protocol included a 3-day food diary which was checked with a parent, and data were entered afterwards using EPIC-Soft. The alternative protocol consisted of two non-consecutive 1-day food diaries followed by EPIC-Soft completion interviews. Both protocols included general and food propensity questionnaires and anthropometric measurements. The protocols were compared using evaluation questionnaires among the participating parents and study personnel. The parents found the questionnaires and instructions for filling in the food diaries understandable. Food description and food quantification was evaluated as problematic by 29 and 15% of the participants for the 3-day diaries versus 15 and 12% for the 1-day diaries. The protocol with 1-day food diaries was evaluated as less burdensome by the parents and logistically more challenging by the interviewers. Both dietary assessment methods with related tools and administration protocols were evaluated as feasible. The administration protocol with two 1-day food diaries with completion interviews offers more advantages for the future pan-European survey in children 0-10 years. The positive evaluation of feasibility of tools and materials is an important step towards harmonised food consumption data at European level among the younger age groups.

  12. A Deconstructive Pedagogy

    ERIC Educational Resources Information Center

    Uba, Laura

    2008-01-01

    This article describes a four-pronged pedagogical protocol for teaching undergraduates how to deconstruct statements, including a list of deconstructive considerations students learn to apply. The protocol also encourages oral participation in class discussions. Three assessment measures demonstrate the protocol's effectiveness: (1) a qualitative…

  13. Boldness, Aggression, and Shoaling Assays for Zebrafish Behavioral Syndromes.

    PubMed

    Way, Gregory P; Southwell, Maura; McRobert, Scott P

    2016-08-29

    A behavioral syndrome exists when specific behaviors interact under different contexts. Zebrafish have been test subjects in recent studies and it is important to standardize protocols to ensure proper analyses and interpretations. In our previous studies, we have measured boldness by monitoring a series of behaviors (time near surface, latency in transitions, number of transitions, and darts) in a 1.5 L trapezoidal tank. Likewise, we quantified aggression by observing bites, lateral displays, darts, and time near an inclined mirror in a rectangular 19 L tank. By dividing a 76 L tank into thirds, we also examined shoaling preferences. The shoaling assay is a highly customizable assay and can be tailored for specific hypotheses. However, protocols for this assay also must be standardized, yet flexible enough for customization. In previous studies, end chambers were either empty, contained 5 or 10 zebrafish, or 5 pearl danios (D. albolineatus). In the following manuscript, we present a detailed protocol and representative data that accompany successful applications of the protocol, which will allow for replication of behavioral syndrome experiments.

  14. Treating Trauma in Addiction with EMDR: A Pilot Study.

    PubMed

    Perez-Dandieu, Béatrice; Tapia, Géraldine

    2014-01-01

    Abstract Objective: This study investigated the effects of standard eye movement desensitization and reprocessing (EMDR) protocol in chronically dependent patients. We propose that reprocessing traumatic memories with EMDR would lead to measurable changes of addiction symptoms. Twelve patients with alcohol and/or drug dependency were randomly assigned to one of two treatment conditions: treatment as usual (TAU) or TAU plus eight sessions of EMDR (TAU+EMDR). Measures of PTSD symptoms, addiction symptoms, depression, anxiety, self-esteem, and alexithymia were included in this study. The TAU+EMDR group showed a significant reduction in PTSD symptoms but not in addiction symptoms. EMDR treatment was also associated with a significant decrease in depressive symptoms, while patients receiving TAU showed no improvement in this area. The TAU+EMDR group also showed significant changes in self-esteem and alexithymia post-treatment. This study suggests that PTSD symptoms can be successfully treated with standard EMDR protocol in substance abuse patients.

  15. Loss-tolerant quantum secure positioning with weak laser sources

    DOE PAGES

    Lim, Charles Ci Wen; Xu, Feihu; Siopsis, George; ...

    2016-09-14

    Quantum position verification (QPV) is the art of verifying the geographical location of an untrusted party. It has recently been shown that the widely studied Bennett & Brassard 1984 (BB84) QPV protocol is insecure after the 3 dB loss point assuming local operations and classical communication (LOCC) adversaries. Here in this paper, we propose a time-reversed entanglement swapping QPV protocol (based on measurement-device-independent quantum cryptography) that is highly robust against quantum channel loss. First, assuming ideal qubit sources, we show that the protocol is secure against LOCC adversaries for any quantum channel loss, thereby overcoming the 3 dB loss limit.more » Then, we analyze the security of the protocol in a more practical setting involving weak laser sources and linear optics. Lastly, in this setting, we find that the security only degrades by an additive constant and the protocol is able to verify positions up to 47 dB channel loss.« less

  16. Quantum private query with perfect user privacy against a joint-measurement attack

    NASA Astrophysics Data System (ADS)

    Yang, Yu-Guang; Liu, Zhi-Chao; Li, Jian; Chen, Xiu-Bo; Zuo, Hui-Juan; Zhou, Yi-Hua; Shi, Wei-Min

    2016-12-01

    The joint-measurement (JM) attack is the most powerful threat to the database security for existing quantum-key-distribution (QKD)-based quantum private query (QPQ) protocols. Wei et al. (2016) [28] proposed a novel QPQ protocol against the JM attack. However, their protocol relies on two-way quantum communication thereby affecting its real implementation and communication efficiency. Moreover, it cannot ensure perfect user privacy. In this paper, we present a new one-way QPQ protocol in which the special way of classical post-processing of oblivious key ensures the security against the JM attack. Furthermore, it realizes perfect user privacy and lower complexity of communication.

  17. Investigation of differences between field and laboratory pH measurements of national atmospheric deposition program/national trends network precipitation samples

    USGS Publications Warehouse

    Latysh, N.; Gordon, J.

    2004-01-01

    A study was undertaken to investigate differences between laboratory and field pH measurements for precipitation samples collected from 135 weekly precipitation-monitoring sites in the National Trends Network from 12/30/1986 to 12/28/1999. Differences in pH between field and laboratory measurements occurred for 96% of samples collected during this time period. Differences between the two measurements were evaluated for precipitation samples collected before and after January 1994, when modifications to sample-handling protocol and elimination of the contaminating bucket o-ring used in sample shipment occurred. Median hydrogen-ion and pH differences between field and laboratory measurements declined from 3.9 ??eq L-1 or 0.10 pH units before the 1994 protocol change to 1.4 ??eq L-1 or 0.04 pH units after the 1994 protocol change. Hydrogen-ion differences between field and laboratory measurements had a high correlation with the sample pH determined in the field. The largest pH differences between the two measurements occurred for high-pH samples (>5.6), typical of precipitation collected in Western United States; however low- pH samples (<5.0) displayed the highest variability in hydrogen-ion differences between field and laboratory analyses. Properly screened field pH measurements are a useful alternative to laboratory pH values for trend analysis, particularly before 1994 when laboratory pH values were influenced by sample-collection equipment.

  18. Trustworthiness of detectors in quantum key distribution with untrusted detectors

    DOE PAGES

    Qi, Bing

    2015-02-25

    Measurement-device-independent quantum key distribution (MDI-QKD) protocol has been demonstrated as a viable solution to detector side-channel attacks. One of the main advantages of MDI-QKD is that the security can be proved without making any assumptions about how the measurement device works. The price to pay is the relatively low secure key rate comparing with conventional quantum key distribution (QKD), such as the decoy-state BB84 protocol. Recently a new QKD protocol, aiming at bridging the strong security of MDI-QKD with the high e ciency of conventional QKD, has been proposed. In this protocol, the legitimate receiver employs a trusted linear opticsmore » network to encode information on photons received from an insecure quantum channel, and then performs a Bell state measurement (BSM) using untrusted detectors. One crucial assumption made in most of these studies is that the untrusted BSM located inside the receiver's laboratory cannot send any unwanted information to the outside. Here in this paper, we show that if the BSM is completely untrusted, a simple scheme would allow the BSM to send information to the outside. Combined with Trojan horse attacks, this scheme could allow Eve to gain information of the quantum key without being detected. Ultimately, to prevent the above attack, either countermeasures to Trojan horse attacks or some trustworthiness to the "untrusted" BSM device is required.« less

  19. Using broadband spatially resolved NIRS to assess muscle oxygenation during altered running protocols

    NASA Astrophysics Data System (ADS)

    Koukourakis, Georg; Vafiadou, Maria; Steimers, André; Geraskin, Dmitri; Neary, Patrick; Kohl-Bareis, Matthias

    2009-07-01

    We used spatially resolved near-infrared spectroscopy (SRS-NIRS) to assess calf and thigh muscle oxygenation during running on a motor-driven treadmill. Two protocols were used: An incremental speed protocol (velocity = 6 - 12 km/h, ▵v = 2 km/h) was performed in 3 minute stages, while a pacing paradigm modulated step frequency alternatively (2.3 Hz [SLow]; 3.3 Hz [SHigh]) during a constant velocity for 2 minutes each. A SRS-NIRS broadband system (600 - 1000 nm) was used to measure total haemoglobin concentration and oxygen saturation (SO2). An accelerometer was placed on the hip joints to measure limb acceleration through the experiment. The data showed that the calf (SO2 58 to 42%) desaturated to a significantly lower level than the thigh (61 to 54%). During the pacing protocol, SO2 was significantly different between the SLow vs. SHigh trials. Additionally, physiological data as measured by spirometry were different between the SLow vs. SHigh pacing trials (VO2 (2563+/- 586 vs. 2503 +/- 605 mL/min). Significant differences in VO2 at the same workload (speed) indicate alterations in mechanical efficiency. These data suggest that SRS broadband NIRS can be used to discern small changes in muscle oxygenation, making this device useful for metabolic exercise studies in addition to spirometry and movement monitoring by accelerometers.

  20. Proof-of-principle experimental realization of a qubit-like qudit-based quantum key distribution scheme

    NASA Astrophysics Data System (ADS)

    Wang, Shuang; Yin, Zhen-Qiang; Chau, H. F.; Chen, Wei; Wang, Chao; Guo, Guang-Can; Han, Zheng-Fu

    2018-04-01

    In comparison to qubit-based protocols, qudit-based quantum key distribution ones generally allow two cooperative parties to share unconditionally secure keys under a higher channel noise. However, it is very hard to prepare and measure the required quantum states in qudit-based protocols in general. One exception is the recently proposed highly error tolerant qudit-based protocol known as the Chau15 (Chau 2015 Phys. Rev. A 92 062324). Remarkably, the state preparation and measurement in this protocol can be done relatively easily since the required states are phase encoded almost like the diagonal basis states of a qubit. Here we report the first proof-of-principle demonstration of the Chau15 protocol. One highlight of our experiment is that its post-processing is based on practical one-way manner, while the original proposal in Chau (2015 Phys. Rev. A 92 062324) relies on complicated two-way post-processing, which is a great challenge in experiment. In addition, by manipulating time-bin qudit and measurement with a variable delay interferometer, our realization is extensible to qudit with high-dimensionality and confirms the experimental feasibility of the Chau15 protocol.

  1. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults.

    PubMed

    Altunkan, Sekip; Ilman, Nevzat; Kayatürk, Nur; Altunkan, Erkan

    2007-08-01

    Electronic blood pressure (BP) measurement devices are the preferred choice of patients owing to their user-friendly nature; however, there is a requirement to investigate the accuracy and reliability of these devices. The objective of this study is to evaluate the accuracy of the Omron M6 upper-arm BP device against the mercury sphygmomanometer in adults and obese adults according to the International Protocol criteria. One hundred and twenty-one patients, older than 30 years of age, were studied and classified on the basis of the range of the International Protocol. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. A total of 33 participants were selected for each validation study. During the validation study, 99 measurements were performed on 33 participants for comparison. The first phase was performed on 15 participants, and if the device passed this phase, 18 more participants were selected. Having a two-fold purpose, this study was conducted on both adult and obese adult patients. Mean discrepancies and standard deviations of the monitor-mercury sphygmomanometer were 1.1+/-4.0 mmHg for systolic BP (SBP) and -0.5+/-3.5 mmHg for diastolic BP (DBP) in the adult group. The device passed phase 1 in 15 participants. In phase 2.1, out of a total of 99 comparisons, 88, 96, and 97 for SBP, and 88, 98, and 99 for DBP were <5, <10, and <15 mmHg, respectively. Mean discrepancies and standard deviations of the monitor-mercury sphygmomanometer were 1.7+/-4.8 mmHg for SBP and -0.8+/-4.3 mmHg for DBP in the obese adult group. The device passed phase 1 in 15 participants. In phase 2.1, out of a total of 99 comparisons, 82, 90, and 97 for SBP, and 80, 97, and 99 for DBP were <5, <10, and <15 mmHg, respectively. It was found that the Omron M6 automatic monitor, which measures BP at the upper arm, produced results in accordance with the criteria of phases 2.1 and 2.2 in both SBP and DBP, when applied to adults and to obese adults. It was concluded that the Omron M6 device, which measures BP at the upper arm, was deemed to be in accordance with the International Protocol criteria and can be recommended for use by adults and obese adults.

  2. Comparison of eye lens dose on neuroimaging protocols between 16- and 64-section multidetector CT: achieving the lowest possible dose.

    PubMed

    Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L

    2009-02-01

    To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.

  3. Development of an ATP measurement method suitable for xenobiotic treatment activated sludge biomass.

    PubMed

    Nguyen, Lan Huong; Chong, Nyuk-Min

    2015-09-01

    Activated sludge consumes a large amount of energy to degrade a xenobiotic organic compound. By tracking the energy inventory of activated sludge biomass during the sludge's degradation of a xenobiotic, any disadvantageous effect on the sludge's performance caused by energy deficiency can be observed. The purpose of this study was to develop a reliable and accurate method for measuring the ATP contents of activated sludge cells that were to degrade a xenobiotic organic. Cell disruption and cellular ATP extraction were performed by a protocol with which xenobiotic degrading activated sludge biomass was washed with SDS, treated by Tris and TCA, and followed by bead blasting. The suspension of disrupted cells was filtered before the filtrate was injected into HPLC that was set at optimal conditions to measure the ATP concentration therein. This extraction protocol and HPLC measurement of ATP was evaluated for its linearity, limits of detection, and reproducibility. Evaluation test results reported a R(2) of 0.999 of linear fit of ATP concentration versus activated sludge concentration, a LOD=0.00045mg/L, a LOQ=0.0015mg/L for HPLC measurement of ATP, a MDL=0.46mg/g SS for ATP extraction protocol, and a recovery efficiency of 96.4±2%. This method of ATP measurement was simple, rapid, reliable, and was unburdened of some limitations other methods may have. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. SIGNIFICANCE OF INCORPORATING MEASURES OF SPERM PRODUCTION AND FUNCTION INTO RAT TOXICOLOGY STUDIES

    EPA Science Inventory

    The rat is the preferred species for reproductive toxicity testing. The inclusion of measures of rat sperm quality, such as motility and morphology, into reproductive test protocols often increases the sensitivity of the test to detect effects, and provides the toxicologist and ...

  5. Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol

    PubMed Central

    Topouchian, Jirar; Agnoletti, Davide; Blacher¹, Jacques; Youssef, Ahmed; Chahine, Mirna N; Ibanez, Isabel; Assemani, Nathalie; Asmar, Roland

    2014-01-01

    Background Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. Methods The four devices measure brachial blood pressure (BP) using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg). The protocol procedures were followed precisely in each of the four studies. Results All four tested devices passed the validation process. The mean differences between the device and mercury readings were: −1.8±5.1 mmHg and −0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and −1.2±4.3 mmHg for the Omron HEM-7420 device; −0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device. Conclusion Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly. PMID:24476688

  6. Respiratory Therapist Job Perceptions: The Impact of Protocol Use.

    PubMed

    Metcalf, Ashley Y; Stoller, James K; Habermann, Marco; Fry, Timothy D

    2015-11-01

    Demand for respiratory care services and staffing levels of respiratory therapists (RTs) is expected to increase over the next several years. Hence, RT job satisfaction will be a critical factor in determining recruitment and retention of RTs. Determinants of RT job satisfaction measures have received little attention in the literature. This study examines the use of respiratory care protocols and associated levels of RT job satisfaction, turnover intentions, and job stress. Four-hundred eighty-one RTs at 44 hospitals responded to an online survey regarding job satisfaction, turnover intentions, and job stress. Random coefficient modeling was used for analysis and to account for the nested structure of the data. Higher levels of RT protocol use were associated with higher levels of job satisfaction, lower rates of turnover intentions, and lower levels of job stress. In addition, RTs with greater experience had higher levels of job satisfaction, and RTs working at teaching hospitals had lower rates of turnover intentions. The study extends prior research by examining how the use of respiratory care protocols favorably affects RTs' perceptions of job satisfaction, turnover intention, and job stress. In a time of increasing demand for respiratory care services, protocols may enhance retention of RTs. Copyright © 2015 by Daedalus Enterprises.

  7. The promise of wearable sensors and ecological momentary assessment measures for dynamical systems modeling in adolescents: a feasibility and acceptability study.

    PubMed

    Brannon, Erin E; Cushing, Christopher C; Crick, Christopher J; Mitchell, Tarrah B

    2016-12-01

    Intervention development can be accelerated by using wearable sensors and ecological momentary assessment (EMA) to study how behaviors change within a person. The purpose of this study was to determine the feasibility and acceptability of a novel, intensive EMA method for assessing physiology, behavior, and psychosocial variables utilizing two objective sensors and a mobile application (app). Adolescents (n = 20) enrolled in a 20-day EMA protocol. Participants wore a physiological monitor and an accelerometer that measured sleep and physical activity and completed four surveys per day on an app. Participants provided approximately 81 % of the expected survey data. Participants were compliant to the wrist-worn accelerometer (75.3 %), which is a feasible measurement of physical activity/sleep (74.1 % complete data). The data capture (47.8 %) and compliance (70.28 %) with the physiological monitor were lower than other study variables. The findings support the use of an intensive assessment protocol to study real-time relationships between biopsychosocial variables and health behaviors.

  8. Measurement of thrombus resolution using three-dimensional ultrasound assessment of deep vein thrombosis volume.

    PubMed

    Zhao, Limin; Prior, Steven J; Kampmann, Meghan; Sorkin, John D; Caldwell, Kevin; Braganza, Melita; McEvoy, Sue; Lal, Brajesh K

    2014-04-01

    Current imaging techniques are limited in their ability to quantify thrombus burden, progression, resolution, and organization over time in patients with acute deep vein thrombosis (DVT). These assessments are critical measures of therapeutic success when thrombolytic or thrombectomy treatment protocols are utilized for DVT. We evaluated the reliability of a new, commercially available method of acquiring and analyzing three-dimensional (3D) ultrasound images of DVTs that measures thrombus volume and echogenicity. We studied 25 consecutive hospital in-patients (18 male, seven female; age range, 37-87 years) with a first episode of acute DVT. Treatment decisions were not influenced by the study protocol. Scanning was performed independently by two sonographers, then the first sonographer repeated the scan. A combination of routine imaging in grayscale, color-flow, and power-Doppler modes (2D transducer) along with volumetric imaging (3D transducer) was performed. Patients underwent imaging at baseline and on one or more follow-up days 7, 14, 21 and 30. Image-processing software loaded on the ultrasound machine was used to obtain thrombus volume and echogenicity measurements. Thrombus volume was reliably determined by our protocol. The median volume of thrombus at baseline was 0.4 cm(3). Mean inter- and intraobserver differences in volume measurements were 0.006 ± 0.26 cm(3) and -0.12 ± 0.29 cm(3) (mean ± standard deviation). Thrombus resolved over time at a rate of -0.042 ± 0.01 cm(3)/day (P < .003). The median echogenicity of thrombus at baseline expressed as the grayscale median value was 59. There was a trend for thrombus organization (measured as echogenicity) to increase with time, +0.36 ± 0.23 grayscale median units/day (P < .13). Adjustment for the use of anticoagulation, gender of subject, or location of DVT in the upper vs lower extremity did not alter the relationship between time and volume or time and echogenicity. We describe a 3D imaging protocol that reliably measures thrombus volume and echogenicity over time. The method is convenient and can be utilized in routine clinical practice. Acute DVT was associated with a reduction in thrombus size and trend for increased echogenicity over 1 month. This protocol will be of increasing value as our appreciation for the deleterious effects of residual thrombus after DVT increases and our utilization of aggressive thrombus removal treatments for acute DVT increases. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. A Novel Quantum Solution to Privacy-Preserving Nearest Neighbor Query in Location-Based Services

    NASA Astrophysics Data System (ADS)

    Luo, Zhen-yu; Shi, Run-hua; Xu, Min; Zhang, Shun

    2018-04-01

    We present a cheating-sensitive quantum protocol for Privacy-Preserving Nearest Neighbor Query based on Oblivious Quantum Key Distribution and Quantum Encryption. Compared with the classical related protocols, our proposed protocol has higher security, because the security of our protocol is based on basic physical principles of quantum mechanics, instead of difficulty assumptions. Especially, our protocol takes single photons as quantum resources and only needs to perform single-photon projective measurement. Therefore, it is feasible to implement this protocol with the present technologies.

  10. Protocol for Short- and Longer-term Spatial Learning and Memory in Mice

    PubMed Central

    Willis, Emily F.; Bartlett, Perry F.; Vukovic, Jana

    2017-01-01

    Studies on the role of the hippocampus in higher cognitive functions such as spatial learning and memory in rodents are reliant upon robust and objective behavioral tests. This protocol describes one such test—the active place avoidance (APA) task. This behavioral task involves the mouse continuously integrating visual cues to orientate itself within a rotating arena in order to actively avoid a shock zone, the location of which remains constant relative to the room. This protocol details the step-by-step procedures for a novel paradigm of the hippocampal-dependent APA task, measuring acquisition of spatial learning during a single 20-min trial (i.e., short-term memory), with spatial memory encoding and retrieval (i.e., long-term memory) assessed by trials conducted over consecutive days. Using the APA task, cognitive flexibility can be assessed using the reversal learning paradigm, as this increases the cognitive load required for efficient performance in the task. In addition to a detailed experimental protocol, this paper also describes the range of its possible applications, the expected key results, as well as the analytical methods to assess the data, and the pitfalls/troubleshooting measures. The protocol described herein is highly robust and produces replicable results, thus presenting an important paradigm that enables the assessment of subtle short-term changes in spatial learning and memory, such as those observed for many experimental interventions. PMID:29089878

  11. Prevention of Tinea Corporis in Collegiate Wrestlers

    PubMed Central

    Hand, James W.; Wroble, Randall R.

    1999-01-01

    Objective: To examine the role of a comprehensive skin disease prevention protocol in conjunction with the use of a barrier cream to prevent tinea corporis (ringworm) in collegiate wrestlers. Design and Setting: We studied a college wrestling team for 16 weeks during 1 season. During the first 8 weeks, no preventive measures were taken. For the remaining 8 weeks, wrestlers were randomized into 2 groups and used either a barrier or a placebo. Subjects: Twenty-two male college wrestlers with a mean age of 20.4 years (range, 18.1 to 23.2), a mean weight of 68.4 kg (range, 55.8 to 130.2), and a mean height of 177.8 cm (range, 168.7 to 186.9). Measurements: We performed skin checks daily. All new or exacerbated lesions were clinically diagnosed by the same team physician and recorded. Results: Cases of tinea corporis declined from 10 diagnosed before initiation of the protocol to 1 after the protocol was initiated. One athlete in the placebo group was found to have tinea corporis versus none in the barrier cream group. Conclusions: Strict adherence to the prevention protocol for skin infections significantly decreased the number of cases of tinea corporis. The use of the barrier cream in conjunction with the prevention protocol did not result in any further statistical reduction in the number of wrestlers who contracted tinea corporis. PMID:16558587

  12. Acute effects of various weighted bat warm-up protocols on bat velocity.

    PubMed

    Reyes, G Francis; Dolny, Dennis

    2009-10-01

    Although research has provided evidence of increased muscular performance following a facilitation set of resistance exercise, this has not been established for use prior to measuring baseball bat velocity. The purpose of this study was to determine the effectiveness of selected weighted bat warm-up protocols to enhance bat velocity in collegiate baseball players. Nineteen collegiate baseball players (age = 20.15 +/- 1.46 years) were tested for upper-body strength by a 3-repetition maximum (RM) bench press (mean = 97.98 +/- 14.54 kg) and mean bat velocity. Nine weighted bat warm-up protocols, utilizing 3 weighted bats (light = 794 g; standard = 850 g; heavy = 1,531 g) were swung in 3 sets of 6 repetitions in different orders. A control trial involved the warm-up protocol utilizing only the standard bat. Pearson product correlation revealed a significant relationship between 3RM strength and pretest bat velocity (r = 0.51, p = 0.01). Repeated measures analysis of variance (ANOVA) revealed no significant treatment effects of warm-up protocol on bat velocity. However, the order of standard, light, heavy bat sequence resulted in the greatest increase in bat velocity (+6.03%). These results suggest that upper-body muscle strength influences bat velocity. It appears that the standard, light, heavy warm-up order may provide the greatest benefit to increase subsequent bat velocity and may warrant use in game situations.

  13. Comparison of IPSM 1990 photon dosimetry code of practice with IAEA TRS‐398 and AAPM TG‐51.

    PubMed Central

    Henríquez, Francisco Cutanda

    2009-01-01

    Several codes of practice for photon dosimetry are currently used around the world, supported by different organizations. A comparison of IPSM 1990 with both IAEA TRS‐398 and AAPM TG‐51 has been performed. All three protocols are based on the calibration of ionization chambers in terms of standards of absorbed dose to water, as it is the case with other modern codes of practice. This comparison has been carried out for photon beams of nominal energies: 4 MV, 6 MV, 8 MV, 10 MV and 18 MV. An NE 2571 graphite ionization chamber was used in this study, cross‐calibrated against an NE 2611A Secondary Standard, calibrated in the National Physical Laboratory (NPL). Absolute dose in reference conditions was obtained using each of these three protocols including: beam quality indices, beam quality conversion factors both theoretical and NPL experimental ones, correction factors for influence quantities and absolute dose measurements. Each protocol recommendations have been strictly followed. Uncertainties have been obtained according to the ISO Guide to the Expression of Uncertainty in Measurement. Absorbed dose obtained according to all three protocols agree within experimental uncertainty. The largest difference between absolute dose results for two protocols is obtained for the highest energy: 0.7% between IPSM 1990 and IAEA TRS‐398 using theoretical beam quality conversion factors. PACS number: 87.55.tm

  14. Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction.

    PubMed

    Kaasalainen, Touko; Palmu, Kirsi; Lampinen, Anniina; Reijonen, Vappu; Leikola, Junnu; Kivisaari, Riku; Kortesniemi, Mika

    2015-09-01

    Medical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis. To evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging. We scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues. Mean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level. Craniosynostosis CT with model-based iterative reconstruction could be performed with a 20-μSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality.

  15. Short-term supervised inpatient physiotherapy exercise protocol improves cardiac autonomic function after coronary artery bypass graft surgery--a randomised controlled trial.

    PubMed

    Mendes, Renata Gonçalves; Simões, Rodrigo Polaquini; De Souza Melo Costa, Fernando; Pantoni, Camila Bianca Falasco; Di Thommazo, Luciana; Luzzi, Sérgio; Catai, Aparecida Maria; Arena, Ross; Borghi-Silva, Audrey

    2010-01-01

    Coronary artery bypass grafting (CABG) is accompanied by severe impairment of cardiac autonomous regulation (CAR). This study aimed to determine whether a short-term physiotherapy exercise protocol post-CABG, during inpatient cardiac rehabilitation (CR), might improve CAR. Seventy-four patients eligible for CABG were recruited and randomised into physiotherapy exercise group (EG) or physiotherapy usual care group (UCG). EG patients underwent a short-term supervised inpatient physiotherapy exercise protocol consisting of an early mobilisation with progressive exercises plus usual care (respiratory exercises). UCG only received respiratory exercises. Forty-seven patients (24 EG and 23 UGC) completed the study. Outcome measures of CAR included linear and non-linear measures of heart rate variability (HRV) assessed before discharge. By hospital discharge, EG presented significantly higher parasympathetic HRV values [rMSSD, high frequency (HF), SD1)], global power (STD RR, SD2), non-linear HRV indexes [detrended fluctuation analysis (DFA)alpha1, DFAalpha2, approximate entropy (ApEn)] and mean RR compared to UCG (p<0.05). Conversely, higher values of mean HR, low frequency (LF) (sympathetic activity) and the LF/HF (global sympatho-vagal balance) were found in the UCG. A short-term supervised physiotherapy exercise protocol during inpatient CR improves CAR at the time of discharge. Thus, exercise-based inpatient CR might be an effective non-pharmacological tool to improve autonomic cardiac tone in patient's post-CABG.

  16. Basal measures of insulin sensitivity and insulin secretion and simplified glucose tolerance tests in dogs.

    PubMed

    Verkest, K R; Fleeman, L M; Rand, J S; Morton, J M

    2010-10-01

    There is need for simple, inexpensive measures of glucose tolerance, insulin sensitivity, and insulin secretion in dogs. The aim of this study was to estimate the closeness of correlation between fasting and dynamic measures of insulin sensitivity and insulin secretion, the precision of fasting measures, and the agreement between results of standard and simplified glucose tolerance tests in dogs. A retrospective descriptive study using 6 naturally occurring obese and 6 lean dogs was conducted. Data from frequently sampled intravenous glucose tolerance tests (FSIGTTs) in 6 obese and 6 lean client-owned dogs were used to calculate HOMA, QUICKI, fasting glucose and insulin concentrations. Fasting measures of insulin sensitivity and secretion were compared with MINMOD analysis of FSIGTTs using Pearson correlation coefficients, and they were evaluated for precision by the discriminant ratio. Simplified sampling protocols were compared with standard FSIGTTs using Lin's concordance correlation coefficients, limits of agreement, and Pearson correlation coefficients. All fasting measures except fasting plasma glucose concentration were moderately correlated with MINMOD-estimated insulin sensitivity (|r| = 0.62-0.80; P < 0.03), and those that combined fasting insulin and glucose were moderately closely correlated with MINMOD-estimated insulin secretion (r = 0.60-0.79; P < 0.04). HOMA calculated using the nonlinear formulae had the closest estimated correlation (r = 0.77 and 0.74) and the best discrimination for insulin sensitivity and insulin secretion (discriminant ratio 4.4 and 3.4, respectively). Simplified sampling protocols with half as many samples collected over 3 h had close agreement with the full sampling protocol. Fasting measures and simplified intravenous glucose tolerance tests reflect insulin sensitivity and insulin secretion derived from frequently sampled glucose tolerance tests with MINMOD analysis in dogs. Copyright 2010 Elsevier Inc. All rights reserved.

  17. [Development of external quality control protocol for CyberKnife beams dosimetry: preliminary tests multicentre].

    PubMed

    Guinement, L; Marchesi, V; Veres, A; Lacornerie, T; Buchheit, I; Peiffert, D

    2013-01-01

    To develop an external quality control procedure for CyberKnife(®) beams. This work conducted in Nancy, has included a test protocol initially drawn by the medical physicist of Nancy and Lille in collaboration with Equal-Estro Laboratory. A head and neck anthropomorphic phantom and a water-equivalent homogeneous cubic plastic test-object, so-called "MiniCube", have been used. Powder and solid thermoluminescent dosimeters as well as radiochromic films have been used to perform absolute and relative dose studies, respectively. The comparison between doses calculated by Multiplan treatment planning system and measured doses have been studied in absolute dose. The dose distributions measured with films and treatment planning system calculations have been compared via the gamma function, configured with different tolerance criteria. This work allowed, via solid thermoluminescent dosimeter measurements, verifying the beam reliability with a reproducibility of 1.7 %. The absolute dose measured in the phantom irradiated by the seven participating centres has shown an error inferior to the standard tolerance limits (± 5 %), for most of participating centres. The relative dose measurements performed at Nancy and by the Equal-Estro laboratory allowed defining the most adequate parameters for gamma index (5 %/2mm--with at least 95 % of pixels satisfying acceptability criteria: γ<1). These parameters should be independent of the film analysis software. This work allowed defining a dosimetric external quality control for CyberKnife(®) systems, based on a reproducible irradiation plan through measurements performed with thermoluminescent dosimeters and radiochromic films. This protocol should be validated by a new series of measurement and taking into account the lessons of this work. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  18. Development of Next Generation Energy Audit Protocols for the Rapid and Advanced Analysis of Building Energy Use

    NASA Astrophysics Data System (ADS)

    Hartley, Christopher Ahlvin

    Current building energy auditing techniques are outdated and lack targeted, actionable information. These analyses only use one year's worth of monthly electricity and gas bills to define energy conservation and efficiency measures. These limited data sets cannot provide robust, directed energy reduction recommendations. The need is apparent for an overhaul of existing energy audit protocols to utilize all data that is available from the building's utility provider, installed energy management system (EMS), and sub-metering devices. This thesis analyzed the current state-of-the-art in energy audits, generated a next generation energy audit protocol, and conducted both audits types on four case study buildings to find out what additional information can be obtained from additional data sources and increased data gathering resolutions. Energy data from each case study building were collected using a variety of means including utility meters, whole building energy meters, EMS systems, and sub-metering devices. In addition to conducting an energy analysis for each case study building using the current and next generation energy audit protocols, two building energy models were created using the programs eQuest and EnergyPlus. The current and next generation energy audit protocol results were compared to one another upon completion. The results show that using the current audit protocols, only variations in season are apparent. Results from the developed next generation energy audit protocols show that in addition to seasonal variations, building heating, ventilation and air conditioning (HVAC) schedules, occupancy schedules, baseline and peak energy demand levels, and malfunctioning equipment can be found. This new protocol may also be used to quickly generate accurate building models because of the increased resolution that yields scheduling information. The developed next generation energy auditing protocol is scalable and can work for many building types across the United States, and perhaps the world.

  19. Exponentially Decelerated Contrast Media Injection Rate Combined With a Novel Patient-Specific Contrast Formula Reduces Contrast Volume Administration and Radiation Dose During Computed Tomography Pulmonary Angiography.

    PubMed

    Saade, Charbel; Mayat, Ahmad; El-Merhi, Fadi

    2016-01-01

    Matching contrast injection timing with vessel dynamics significantly improves vessel opacification and reduces contrast dose in the assessment of pulmonary embolism during computed tomography (CT) pulmonary angiography. The aim of this study was to investigate opacification of the pulmonary vasculature (PV) during CT pulmonary angiography using a patient-specific contrast formula (PSCF) and exponentially decelerated contrast media (EDCM) injection rate. Institutional review board approved this retrospective study. Computed tomography pulmonary angiography was performed on 200 patients with suspected pulmonary embolism using a 64-channel CT scanner. Patient demographics were equally distributed. Patients were randomly assigned to 2 equal protocol groups: protocol A used a PSCF, and protocol B involved the use of a PSCF combined with EDCM. The mean cross-sectional opacification profile of 8 central and 11 peripheral PVs were measured for each patient, and arteriovenous contrast ratio was calculated. Protocols were compared using Mann-Whitney U nonparametric statistics. Jackknife alternative free-response receiver operating characteristic analyses were used to assess diagnostic efficacy. Interobserver variations were investigated using kappa methods. A number of pulmonary arteries demonstrated increases in opacification (P < 0.02) for protocol B compared with A, whereas opacification in all veins was reduced in protocol B (P < 0.03). Subsequently, increased arteriovenous contrast ratio in protocol B compared with A was observed at all anatomic locations (P < 0.0002). An increase in jackknife alternative free-response receiver operating characteristic figure of merit (P < 0.0002) and interobserver variation was observed with protocol B compared with protocol A (κ = 0.3-0.73). Mean contrast volume was reduced in protocol B (29 [4] mL) compared with protocol A (33 [9] mL). Mean effective radiation dose in protocol B (1.2 [0.4] mSv) was reduced by 14% compared with protocol A (1.4 [0.6] mSv). Significant improvements in visualization of the PV can be achieved with a low contrast volume using an EDCM and PSCF. The reduced risk of cancer induction is highlighted.

  20. Periodically Relieving Ischial Sitting Load to Decrease the Risk of Pressure Ulcers

    PubMed Central

    Makhsous, Mohsen; Rowles, Diane M.; Rymer, William Z.; Bankard, James; Nam, Ellis K.; Chen, David; Lin, Fang

    2010-01-01

    Objective To investigate the relieving effect on interface pressure of an alternate sitting protocol involving a sitting posture that reduces ischial support. Design Repeated measures in 2 protocols on 3 groups of subjects. Setting Laboratory. Participants Twenty able-bodied persons, 20 persons with paraplegia, and 20 persons with tetraplegia. Interventions Two 1-hour protocols were used: alternate and normal plus pushup. In the alternate protocol, sitting posture was alternated every 10 minutes between normal (sitting upright with ischial support) and with partially removed ischial support (WO-BPS) postures; in the normal plus pushup protocol, sitting was in normal posture with pushups (lifting the subject off the seat) performed every 20 minutes. Main Outcome Measure Interface pressure on seat and backrest. Results In WO-BPS posture, the concentrated interface pressure observed around the ischia in normal posture was significantly repositioned to the thighs. By cyclically repositioning the interface pressure, the alternate protocol was superior to the normal plus pushup protocol in terms of a significantly lower average interface pressure over the buttocks. Conclusions A sitting protocol periodically reducing the ischial support helps lower the sitting load on the buttocks, especially the area close to ischial tuberosities. PMID:17601466

  1. Improving post-stroke dysphagia outcomes through a standardized and multidisciplinary protocol: an exploratory cohort study.

    PubMed

    Gandolfi, Marialuisa; Smania, Nicola; Bisoffi, Giulia; Squaquara, Teresa; Zuccher, Paola; Mazzucco, Sara

    2014-12-01

    Stroke is a major cause of dysphagia. Few studies to date have reported on standardized multidisciplinary protocolized approaches to the management of post-stroke dysphagia. The aim of this retrospective cohort study was to evaluate the impact of a standardized multidisciplinary protocol on clinical outcomes in patients with post-stroke dysphagia. We performed retrospective chart reviews of patients with post-stroke dysphagia admitted to the neurological ward of Verona University Hospital from 2004 to 2008. Outcomes after usual treatment for dysphagia (T- group) were compared versus outcomes after treatment under a standardized diagnostic and rehabilitative multidisciplinary protocol (T+ group). Outcome measures were death, pneumonia on X-ray, need for respiratory support, and proportion of patients on tube feeding at discharge. Of the 378 patients admitted with stroke, 84 had dysphagia and were enrolled in the study. A significantly lower risk of in-hospital death (odds ratio [OR] 0.20 [0.53-0.78]), pneumonia (OR 0.33 [0.10-1.03]), need for respiratory support (OR 0.48 [0.14-1.66]), and tube feeding at discharge (OR 0.30 [0.09-0.91]) was recorded for the T+ group (N = 39) as compared to the T- group (N = 45). The adjusted OR showed no difference between the two groups for in-hospital death and tube feeding at discharge. Use of a standardized multidisciplinary protocolized approach to the management of post-stroke dysphagia may significantly reduce rates of aspiration pneumonia, in-hospital mortality, and tube feeding in dysphagic stroke survivors. Consistent with the study's exploratory purposes, our findings suggest that the multidisciplinary protocol applied in this study offers an effective model of management of post-stroke dysphagia.

  2. Health information technology adoption: Understanding research protocols and outcome measurements for IT interventions in health care.

    PubMed

    Colicchio, Tiago K; Facelli, Julio C; Del Fiol, Guilherme; Scammon, Debra L; Bowes, Watson A; Narus, Scott P

    2016-10-01

    To classify and characterize the variables commonly used to measure the impact of Information Technology (IT) adoption in health care, as well as settings and IT interventions tested, and to guide future research. We conducted a descriptive study screening a sample of 236 studies from a previous systematic review to identify outcome measures used and the availability of data to calculate these measures. We also developed a taxonomy of commonly used measures and explored setting characteristics and IT interventions. Clinical decision support is the most common intervention tested, primarily in non-hospital-based clinics and large academic hospitals. We identified 15 taxa representing the 79 most commonly used measures. Quality of care was the most common category of these measurements with 62 instances, followed by productivity (11 instances) and patient safety (6 instances). Measures used varied according to type of setting, IT intervention and targeted population. This study provides an inventory and a taxonomy of commonly used measures that will help researchers select measures in future studies as well as identify gaps in their measurement approaches. The classification of the other protocol components such as settings and interventions will also help researchers identify underexplored areas of research on the impact of IT interventions in health care. A more robust and standardized measurement system and more detailed descriptions of interventions and settings are necessary to enable comparison between studies and a better understanding of the impact of IT adoption in health care settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Lung donor treatment protocol in brain dead-donors: A multicenter study.

    PubMed

    Miñambres, Eduardo; Pérez-Villares, Jose Miguel; Chico-Fernández, Mario; Zabalegui, Arturo; Dueñas-Jurado, Jose María; Misis, Maite; Mosteiro, Fernando; Rodriguez-Caravaca, Gil; Coll, Elisabeth

    2015-06-01

    The shortage of lung donors for transplantation is the main limitation among patients awaiting this type of surgery. We previously demonstrated that an intensive lung donor-treatment protocol succeeded in increasing the lung procurement rate. We aimed to validate our protocol for centers with or without lung transplant programs. A quasi-experimental study was performed to compare lung donor rate before (historical group, 2010 to 2012) and after (prospective group, 2013) the application of a lung management protocol for donors after brain death (DBDs) in six Spanish hospitals. Lung donor selection criteria remained unchanged in both periods. Outcome measures for lung recipients were early survival and primary graft dysfunction (PGD) rates. A total of 618 DBDs were included: 453 in the control period and 165 in the protocol period. Donor baseline characteristics were similar in both periods. Lung donation rate in the prospective group was 27.3%, more than twice that of the historical group (13%; p < 0.001). The number of lungs retrieved, grafts transplanted, and transplants performed more than doubled over the study period. No differences in early recipients' survival between groups were observed (87.6% vs. 84.5%; p = 0.733) nor in the rate of PGD. Implementing our intensive lung donor-treatment protocol increases lung procurement rates. This allows more lung transplants to be performed without detriment to either early survival or PGD rate. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  4. Communication and protocol compliance and their relation to the quality of cardiopulmonary resuscitation (CPR): A mixed-methods study of simulated telephone-assisted CPR.

    PubMed

    Nord-Ljungquist, Helena; Brännström, Margareta; Bohm, Katarina

    2015-07-01

    In the event of a cardiac arrest, emergency medical dispatchers (EMDs) play a critical role by providing telephone-assisted cardiopulmonary resuscitation (T-CPR) to laypersons. The aim of our investigation was to describe compliance with the T-CPR protocol, the performance of the laypersons in a simulated T-CPR situation, and the communication between laypersons and EMDs during these actions. We conducted a retrospective observational study by analysing 20 recorded video and audio files. In a simulation, EMDs provided laypersons with instructions following T-CPR protocols. These were then analysed using a mixed method with convergent parallel design. If the EMDs complied with the T-CPR protocol, the laypersons performed the correct procedures in 71% of the actions. The single most challenging instruction of the T-CPR protocol, for both EMDs and laypersons, was airway control. Mean values for compression depth and frequency did not reach established guideline goals for CPR. Proper application of T-CPR protocols by EMDs resulted in better performance by laypersons in CPR. The most problematic task for EMDs as well for laypersons was airway management. The study results did not establish that the quality of communication between EMDs and laypersons performing CPR in a cardiac arrest situation led to statistically different outcomes, as measured by the quality and effectiveness of the CPR delivered. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Early prediction of post-thyroidectomy hypocalcemia by early parathyroid hormone measurement.

    PubMed

    Yetkin, Gurkan; Citgez, Bulent; Yazici, Pinar; Mihmanli, Mehmet; Sit, Erhan; Uludag, Mehmet

    2016-01-01

    Hypoparathyroidism is the most common complication of total thyroidectomy (TT). Postthyroidectomy hypocalcemia occurs 24 to 48 hours after the operation. It prolongs the length of hospital stay, even though transient in most cases. The aim of this study was to predetermine the patients who may develop postthyroidectomy hypocalcemia by using early postoperative serum intact parathormone (iPTH) and calcium (Ca2+) measurements, and to investigate the effects of early initiated oral calcium and vitamin D treatments on the development of transient hypocalcemia. Patients who underwent TT after initiation of the early iPTH measurement protocol in January 2013 were included into the study group (Group 1, n=202). The control group (Group 2) was composed of 72 patients who underwent TT before the protocol. Prior to the initiation of the protocol, Ca2+ was measured instead of iPTH. In the study group, the serum Ca2+ and iPTH levels were measured before surgery, and 1 and 24-hours after. A calcium level below 8 mg/dL was accepted as biochemical hypocalcaemia, and a iPTH level under 15pg/mL was accepted as hypoparathyroidism. In the study group, patients with below normal iPTH levels were treated with prophylactic oral calcium and vitamin D. In Group 1, 15.8% (n=32) of the patients had hypoparathyroidism on the 1h and 24 h iPTH measurements. There was no statistically difference with regard to PTH levels measured in the postoperative 1st hour and at the 24th hour (p= 0.078). Biochemical hypocalcaemia developed in 16 (7.9%) and 13 (18%) patients in Groups 1 and 2, respectively, 24 hours after thyroidectomy (p<0.05). Mean length of hospital stay was 2.17 and 3.26 days in the study and control groups (p<0.001). We believe that the measurement of iPTH levels one hour after thyroidectomy, when compared to levels at 24 hours after procedure, is a safe, reliable, and adequate method for the effective management of plausible postthyroidectomic hypocalcemia. It yields significantly shorter hospital stay periods. Calcium, Hypoparathyroidism, Postoperative complication, Total thyroidectomy.

  6. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    PubMed

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  7. Wear measurement of dental tissues and materials in clinical studies: A systematic review.

    PubMed

    Wulfman, C; Koenig, V; Mainjot, A K

    2018-06-01

    This study aims to systematically review the different methods used for wear measurement of dental tissues and materials in clinical studies, their relevance and reliability in terms of accuracy and precision, and the performance of the different steps of the workflow taken independently. An exhaustive search of clinical studies related to wear of dental tissues and materials reporting a quantitative measurement method was conducted. MedLine, Embase, Scopus, Cochrane Library and Web of Science databases were used. Prospective studies, pilot studies and case series (>10 patients), as long as they contained a description of wear measurement methodology. Only studies published after 1995 were considered. After duplicates' removal, 495 studies were identified, and 41 remained for quantitative analysis. Thirty-four described wear-measurement protocols, using digital profilometry and superimposition, whereas 7 used alternative protocols. A specific form was designed to analyze the risk of bias. The methods were described in terms of material analyzed; study design; device used for surface acquisition; matching software details and settings; type of analysis (vertical height-loss measurement vs volume loss measurement); type of area investigated (entire occlusal area or selective areas); and results. There is a need of standardization of clinical wear measurement. Current methods exhibit accuracy, which is not sufficient to monitor wear of restorative materials and tooth tissues. Their performance could be improved, notably limiting the use of replicas, using standardized calibration procedures and positive controls, optimizing the settings of scanners and matching softwares, and taking into account unusable data. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  8. How to implement a clinical pathway for intensive glucose regulation in acute coronary syndromes.

    PubMed

    de Mulder, Maarten; Zwaan, Esther; Wielinga, Yvonne; Stam, Frank; Umans, Victor A W M

    2009-06-01

    Hyperglycemia upon admission of myocardial infarction patients predicts inferior clinical outcomes. Current strategies investigating hyperglycemia correction mostly use glucose-driven protocols. Implementation of these often labor-intensive protocols might be facilitated with the approach of a clinical pathway. Therefore, we evaluated the implementation of our glucose-driven protocol.We adapted a protocol for use in our coronary care unit (CCU), which was implemented according to the steps of a clinical pathway. To compensate for carbohydrates in meals we additionally developed a regimen of subcutaneous insulin.Protocol adherence was facilitated with a Web-based insulin calculator. All hyperglycemic patients admitted to the CCU were eligible for treatment according to this protocol.In a 4-month period, 643 glucose measurements were obtained in hyperglycemic patients admitted to our CCU. Patients were treated intensively with IV insulin for 35 hours and had 23 glucose measurements in this time span on average. This regimen achieved a median glucose of 6.2 mmol/L. Severe hypoglycemia occurred in only 1.1% of measurements and was without severe clinical side effects.Introduction of new intensive insulin protocol according to the steps of a clinical pathway is safe and feasible. The presence of a clinical pathway coordinator and sound communication are important conditions for successful introduction, which can be further aided with a computerized calculator.

  9. Evaluation of a new chest tube removal protocol using digital air leak monitoring after lobectomy: a prospective randomised trial.

    PubMed

    Brunelli, Alessandro; Salati, Michele; Refai, Majed; Di Nunzio, Luca; Xiumé, Francesco; Sabbatini, Armando

    2010-01-01

    The objective of this randomised trial was to assess the effectiveness of a new fast-track chest tube removal protocol taking advantage of digital monitoring of air leak compared to a traditional protocol using visual and subjective assessment of air leak (bubbles). One hundred and sixty-six patients submitted to pulmonary lobectomy for lung cancer were randomised in two groups with different chest tube removal protocols: (1) in the new protocol, chest tube was removed based on digitally recorded measurements of air leak flow; (2) in the traditional protocol, the chest tube removal was based on an instantaneous assessment of air leak during daily rounds. The two groups were compared in terms of chest tube duration, hospital stay and costs. The two groups were well matched for several preoperative and operative variables. Compared to the traditional protocol, the new digital recording protocol showed mean reductions in chest tube duration (p=0.0007), hospital stay (p=0.007) of 0.9 day, and a mean cost saving of euro 476 per patient (p=0.008). In the new chest tube removal protocol, 51% of patients had their chest tube removed by the second postoperative day versus only 12% of those in the traditional protocol. The application of a chest tube removal protocol using a digital drainage unit featuring a continuous recording of air leak was safe and cost effective. Although future studies are warranted to confirm these results in other settings, the use of this new protocol is now routinely applied in our practice. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  10. PACIFIC NORTHWEST SIDE-BY-SIDE PROTOCOL COMPARISON TEST

    EPA Science Inventory

    Eleven state, tribal, and federal agencies participated during summer 2005 in a side-by-side comparison of protocols used to measure common in-stream physical attributes to help determine which protocols are best for determining status and trend of stream/watershed condition. Th...

  11. National Sample Assessment Protocols

    ERIC Educational Resources Information Center

    Ministerial Council on Education, Employment, Training and Youth Affairs (NJ1), 2012

    2012-01-01

    These protocols represent a working guide for planning and implementing national sample assessments in connection with the national Key Performance Measures (KPMs). The protocols are intended for agencies involved in planning or conducting national sample assessments and personnel responsible for administering associated tenders or contracts,…

  12. Assisted closed-loop optimization of SSVEP-BCI efficiency

    PubMed Central

    Fernandez-Vargas, Jacobo; Pfaff, Hanns U.; Rodríguez, Francisco B.; Varona, Pablo

    2012-01-01

    We designed a novel assisted closed-loop optimization protocol to improve the efficiency of brain-computer interfaces (BCI) based on steady state visually evoked potentials (SSVEP). In traditional paradigms, the control over the BCI-performance completely depends on the subjects' ability to learn from the given feedback cues. By contrast, in the proposed protocol both the subject and the machine share information and control over the BCI goal. Generally, the innovative assistance consists in the delivery of online information together with the online adaptation of BCI stimuli properties. In our case, this adaptive optimization process is realized by (1) a closed-loop search for the best set of SSVEP flicker frequencies and (2) feedback of actual SSVEP magnitudes to both the subject and the machine. These closed-loop interactions between subject and machine are evaluated in real-time by continuous measurement of their efficiencies, which are used as online criteria to adapt the BCI control parameters. The proposed protocol aims to compensate for variability in possibly unknown subjects' state and trait dimensions. In a study with N = 18 subjects, we found significant evidence that our protocol outperformed classic SSVEP-BCI control paradigms. Evidence is presented that it takes indeed into account interindividual variabilities: e.g., under the new protocol, baseline resting state EEG measures predict subjects' BCI performances. This paper illustrates the promising potential of assisted closed-loop protocols in BCI systems. Probably their applicability might be expanded to innovative uses, e.g., as possible new diagnostic/therapeutic tools for clinical contexts and as new paradigms for basic research. PMID:23443214

  13. Assisted closed-loop optimization of SSVEP-BCI efficiency.

    PubMed

    Fernandez-Vargas, Jacobo; Pfaff, Hanns U; Rodríguez, Francisco B; Varona, Pablo

    2013-01-01

    We designed a novel assisted closed-loop optimization protocol to improve the efficiency of brain-computer interfaces (BCI) based on steady state visually evoked potentials (SSVEP). In traditional paradigms, the control over the BCI-performance completely depends on the subjects' ability to learn from the given feedback cues. By contrast, in the proposed protocol both the subject and the machine share information and control over the BCI goal. Generally, the innovative assistance consists in the delivery of online information together with the online adaptation of BCI stimuli properties. In our case, this adaptive optimization process is realized by (1) a closed-loop search for the best set of SSVEP flicker frequencies and (2) feedback of actual SSVEP magnitudes to both the subject and the machine. These closed-loop interactions between subject and machine are evaluated in real-time by continuous measurement of their efficiencies, which are used as online criteria to adapt the BCI control parameters. The proposed protocol aims to compensate for variability in possibly unknown subjects' state and trait dimensions. In a study with N = 18 subjects, we found significant evidence that our protocol outperformed classic SSVEP-BCI control paradigms. Evidence is presented that it takes indeed into account interindividual variabilities: e.g., under the new protocol, baseline resting state EEG measures predict subjects' BCI performances. This paper illustrates the promising potential of assisted closed-loop protocols in BCI systems. Probably their applicability might be expanded to innovative uses, e.g., as possible new diagnostic/therapeutic tools for clinical contexts and as new paradigms for basic research.

  14. Using salivary cortisol to measure the effects of a Wilbarger protocol-based procedure on sympathetic arousal: a pilot study.

    PubMed

    Kimball, Judith G; Lynch, Keara M; Stewart, Kelli C; Williams, Nicole E; Thomas, Meghan A; Atwood, Kam D

    2007-01-01

    This study investigated changes in salivary cortisol, the stress hormone, after administration of a procedure based on the Wilbarger protocol to children diagnosed with sensory defensiveness (SD), a type of sensory modulation dysfunction. Using a single-subject design across participants, we studied 4 boys with SD ages 3 to 5 years. Each participant completed four sessions consisting of the collection of a saliva sample, administration of a procedure based on the Wilbarger protocol, 15 min of quiet neutral activities to allow time for any changes in cortisol level to manifest in the saliva, and the second collection of saliva. Saliva samples were analyzed using enzyme-linked immunosorbent assay (ELISA). Salivary cortisol levels in all participants changed after each of four applications of a procedure based on the Wilbarger protocol. The cortisol levels of 2 children whose levels were relatively higher on pretest decreased at each posttest. The levels of 1 child whose cortisol was higher on pretest three times decreased those three times and increased the one time the pretest cortisol was lower. The levels of 1 child who had the lowest cortisol levels of any of the children increased each time. Therefore, in all participants, cortisol moved in the direction of modulation. In these 4 boys, a procedure based on the Wilbarger protocol modulated cortisol levels toward a middle range. This pilot study indicates that there is an association between sympathetic nervous system response and the Wilbarger protocol-based procedure, as indicated by salivary cortisol levels.

  15. Validating an Observation Protocol to Measure Special Education Teacher Effectiveness

    ERIC Educational Resources Information Center

    Johnson, Evelyn S.; Semmelroth, Carrie L.

    2015-01-01

    This study used Kane's (2013) Interpretation/Use Argument (IUA) to measure validity on the Recognizing Effective Special Education Teachers (RESET) observation tool. The RESET observation tool is designed to evaluate special education teacher effectiveness using evidence-based instructional practices as the basis for evaluation. In alignment with…

  16. Real-time spectral characterization of a photon pair source using a chirped supercontinuum seed.

    PubMed

    Erskine, Jennifer; England, Duncan; Kupchak, Connor; Sussman, Benjamin

    2018-02-15

    Photon pair sources have wide ranging applications in a variety of quantum photonic experiments and protocols. Many of these protocols require well controlled spectral correlations between the two output photons. However, due to low cross-sections, measuring the joint spectral properties of photon pair sources has historically been a challenging and time-consuming task. Here, we present an approach for the real-time measurement of the joint spectral properties of a fiber-based four wave mixing source. We seed the four wave mixing process using a broadband chirped pulse, studying the stimulated process to extract information regarding the spontaneous process. In addition, we compare stimulated emission measurements with the spontaneous process to confirm the technique's validity. Joint spectral measurements have taken many hours historically and several minutes with recent techniques. Here, measurements have been demonstrated in 5-30 s depending on resolution, offering substantial improvement. Additional benefits of this approach include flexible resolution, large measurement bandwidth, and reduced experimental overhead.

  17. Impact of a lung transplantation donor-management protocol on lung donation and recipient outcomes.

    PubMed

    Angel, Luis F; Levine, Deborah J; Restrepo, Marcos I; Johnson, Scott; Sako, Edward; Carpenter, Andrea; Calhoon, John; Cornell, John E; Adams, Sandra G; Chisholm, Gary B; Nespral, Joe; Roberson, Ann; Levine, Stephanie M

    2006-09-15

    One of the limitations associated with lung transplantation is the lack of available organs. To determine whether a lung donor-management protocol could increase the number of lungs for transplantation without affecting the survival rates of the recipients. We implemented the San Antonio Lung Transplant protocol for managing potential lung donors according to modifications of standard criteria for donor selection and strategies for donor management. We then compared information gathered during a 4-yr period, during which the protocol was used with information gathered during a 4-yr period before protocol implementation. Primary outcome measures were the procurement rate of lungs and the 30-d and 1-yr survival rates of recipients. We reviewed data from 711 potential lung donors. The mean rate of lung procurement was significantly higher (p < 0.0001) during the protocol period (25.5%) than during the pre-protocol period (11.5%), with an estimated risk ratio of 2.2 in favor of the protocol period. More patients received transplants during the protocol period (n = 121) than during the pre-protocol period (n = 53; p < 0.0001). Of 98 actual lung donors during the protocol period, 53 (54%) had initially been considered poor donors; these donors provided 64 (53%) of the 121 lung transplants. The type of donor was not associated with significant differences in recipients' 30-d and 1-yr survival rates or any clinical measures of adequate graft function. The protocol was associated with a significant increase in the number of lung donors and transplant procedures without compromising pulmonary function, length of stay, or survival of the recipients.

  18. The NINDS-Canadian stroke network vascular cognitive impairment neuropsychology protocols in Chinese.

    PubMed

    Wong, Adrian; Xiong, Yun-yun; Wang, Defeng; Lin, Shi; Chu, Winnie W C; Kwan, Pauline W K; Nyenhuis, David; Black, Sandra E; Wong, Ka Sing Lawrence; Mok, Vincent

    2013-05-01

    Vascular cognitive impairment (VCI) affects up to half of stroke survivors and predicts poor outcomes. Valid and reliable assessement for VCI is lacking, especially for the Chinese population. In 2005, the National Institute of Neurological Disorders and Stroke and Canadian Stroke Network (NINDS-CSN) Harmonisation workshop proposed a set of three neuropsychology protocols for VCI evaluation. This paper is to introduce the protocol design and to report the psychometric properties of the Chinese NINDS-CSN VCI protocols. Fifty patients with mild stroke (mean National Institute of Health Stroke Scale 2.2 (SD=3.2)) and 50 controls were recruited. The NINDS-CSN VCI protocols were adapted into Chinese. We assessed protocols' (1) external validity, defined by how well the protocol summary scores differentiated patients from controls using receiver operating characteristics (ROC) curve analysis; (2) concurrent validity, by correlations with functional measures including Stroke Impact Scale memory score and Chinese Disability Assessment for Dementia; (3) internal consistency; and (4) ease of administration. All three protocols differentiated patients from controls (area under ROC for the three protocols between 0.77 to 0.79, p<0.001), and significantly correlated with the functional measures (Pearson r ranged from 0.37 to 0.51). A cut-off of 19/20 on MMSE identified only one-tenth of patients classified as impaired on the 5-min protocol. Cronbach's α across the four cognitive domains of the 60-min protocol was 0.78 for all subjects and 0.76 for stroke patients. The Chinese NINDS-CSN VCI protocols are valid and reliable for cognitive assessment in Chinese patients with mild stroke.

  19. Transient quantum fluctuation theorems and generalized measurements

    NASA Astrophysics Data System (ADS)

    Prasanna Venkatesh, B.; Watanabe, Gentaro; Talkner, Peter

    2014-01-01

    The transient quantum fluctuation theorems of Crooks and Jarzynski restrict and relate the statistics of work performed in forward and backward forcing protocols. So far, these theorems have been obtained under the assumption that the work is determined by two projective energy measurements, one at the end, and the other one at the beginning of each run of the protocol. We found that one can replace these two projective measurements only by special error-free generalized energy measurements with pairs of tailored, protocol-dependent post-measurement states that satisfy detailed balance-like relations. For other generalized measurements, the Crooks relation is typically not satisfied. For the validity of the Jarzynski equality, it is sufficient that the first energy measurements are error-free and the post-measurement states form a complete orthonormal set of elements in the Hilbert space of the considered system. Additionally, the effects of the second energy measurements must have unit trace. We illustrate our results by an example of a two-level system for different generalized measurements.

  20. Transient quantum fluctuation theorems and generalized measurements

    NASA Astrophysics Data System (ADS)

    Prasanna Venkatesh, B.; Watanabe, Gentaro; Talkner, Peter

    2014-05-01

    The transient quantum fluctuation theorems of Crooks and Jarzynski restrict and relate the statistics of work performed in forward and backward forcing protocols. So far, these theorems have been obtained under the assumption that the work is determined by two projective energy measurements, one at the end, and the other one at the beginning of each run of the protocol.We found that one can replace these two projective measurements only by special error-free generalized energy measurements with pairs of tailored, protocol-dependent post-measurement states that satisfy detailed balance-like relations. For other generalized measurements, the Crooks relation is typically not satisfied. For the validity of the Jarzynski equality, it is sufficient that the first energy measurements are error-free and the post-measurement states form a complete orthonormal set of elements in the Hilbert space of the considered system. Additionally, the effects of the second energy measurements must have unit trace. We illustrate our results by an example of a two-level system for different generalized measurements.

  1. Effects of Adding an Internet-Based Pain Coping Skills Training Protocol to a Standardized Education and Exercise Program for People With Persistent Hip Pain (HOPE Trial): Randomized Controlled Trial Protocol.

    PubMed

    Bennell, Kim L; Rini, Christine; Keefe, Francis; French, Simon; Nelligan, Rachel; Kasza, Jessica; Forbes, Andrew; Dobson, Fiona; Abbott, J Haxby; Dalwood, Andrew; Vicenzino, Bill; Harris, Anthony; Hinman, Rana S

    2015-10-01

    Persistent hip pain in older people is usually due to hip osteoarthritis (OA), a major cause of pain, disability, and psychological dysfunction. The purpose of this study is to evaluate whether adding an Internet-based pain coping skills training (PCST) protocol to a standardized intervention of education followed by physical therapist-instructed home exercise leads to greater reductions in pain and improvements in function. An assessor-, therapist-, and participant-blinded randomized controlled trial will be conducted. The study will be conducted in a community setting. The participants will be 142 people over 50 years of age with self-reported hip pain consistent with hip OA. Participants will be randomly allocated to: (1) a control group receiving a 24-week standardized intervention comprising an 8-week Internet-based education package followed by 5 individual physical therapy exercise sessions plus home exercises (3 times weekly) or (2) a PCST group receiving an 8-week Internet-based PCST protocol in addition to the control intervention. Outcomes will be measured at baseline and 8, 24, and 52 weeks, with the primary time point at 24 weeks. Primary outcomes are hip pain on walking and self-reported physical function. Secondary outcomes include health-related quality-of-life, participant-perceived treatment response, self-efficacy for pain management and function, pain coping attempts, pain catastrophizing, and physical activity. Measurements of adherence, adverse events, use of health services, and process measures will be collected at 24 and 52 weeks. Cost-effectiveness will be assessed at 52 weeks. A self-reported diagnosis of persistent hip pain will be used. The findings will help determine whether adding an Internet-based PCST protocol to standardized education and physical therapist-instructed home exercise is more effective than education and exercise alone for persistent hip pain. This study has the potential to guide clinical practice toward innovative modes of psychosocial health care provision. © 2015 American Physical Therapy Association.

  2. High-Dimensional Multi-particle Cat-Like State Teleportation

    NASA Astrophysics Data System (ADS)

    Zeng, Bei; Liu, Xiao-Shu; Li, Yan-Song; Long, Gui-Lu

    2002-11-01

    Two kinds of M-particle d-dimensional Schmidt-form entangled state teleportation protocols are presented. In the first protocol, the teleportation is achieved by d-dimensional Bell-basis measurements, while in the second protocol it is realized by d-dimensional GHZ-basis measurement. The project supported by the Major State Basic Research Development Program under Grant No. G200077400, National Natural Science Foundation of China under Grant No. 60073009, the Fok Ying Tung Education Foundation, and the Excellent Young University Teachers' Fund of Education Ministry of China

  3. Chapter 14: Chiller Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Tiessen, Alex

    This protocol defines a chiller measure as a project that directly impacts equipment within the boundary of a chiller plant. A chiller plant encompasses a chiller - or multiple chillers - and associated auxiliary equipment. This protocol primarily covers electric-driven chillers and chiller plants. It does not include thermal energy storage and absorption chillers fired by natural gas or steam, although a similar methodology may be applicable to these chilled water system components.

  4. A Novel Combination Therapy for Patients With Dry Eye Disease: A Pilot Study.

    PubMed

    Smith, Will; McMahon, David; Nymark, Maria

    2018-05-01

    Context • Approximately 25% of the US population suffers from dry eyes or some abnormality of the exposed ocular surface. Investigation of effective modalities for their management is needed. Objective • The study intended to examine the efficacy of a proprietary, daily, Dry Eye Protocol consisting of daily use of a moist, heated, ocular compress and intake of an omega-3 dietary supplement in treatment of ocular surface disease. Design • The research team designed a 4-wk, clinically based, open-label, multicenter cohort study. Setting • The study took place at 6 private eye care practices throughout the United States: Beverly Hills, CA, USA; San Diego, CA, USA; Sunnyvale, CA, USA; Park City, UT, USA; Tarpon Spring, FL, USA; and Kennewick, WA, USA. Participants • Participants were adults between 18 and 75 y of age who had established ocular surface disease based on clinical findings and the results of testing using the ocular surface disease index (OSDI). Intervention • For period of 30 d, participants used a combined daily protocol that included (1) application of a moist, heated, eye compress and (2) a nutritional therapy via an omega-3 supplement in an oral triglyceride form. Outcome Measures • Measures included the OSDI and a test of tear break-up time (TBUT). Results • Of the original 35 participants, 33 completed the 4-wk protocol. The participants using the proprietary Dry Eye Protocol showed significant improvements from baseline, demonstrated by a 49% decrease in OSDI scores (P = .0015); and 46% of participants reported becoming asymptomatic of dry eye symptoms. A significant improvement was also observed in TBUT, increasing from 3.0 to 5.4 s. Conclusions • Daily use of the proprietary Dry Eye Protocol that included a high dosage of triglyceride omega-3 and use of a moist, heated, compress daily showed significant improvement for participants in OSDI and TBUT and should be considered to be a first-line therapy for patients with dry eye disease.

  5. Efficacy of the unified protocol for the treatment of emotional disorders in the Spanish public mental health system using a group format: study protocol for a multicenter, randomized, non-inferiority controlled trial.

    PubMed

    Osma, Jorge; Suso-Ribera, Carlos; García-Palacios, Azucena; Crespo-Delgado, Elena; Robert-Flor, Cristina; Sánchez-Guerrero, Ana; Ferreres-Galan, Vanesa; Pérez-Ayerra, Luisa; Malea-Fernández, Amparo; Torres-Alfosea, Mª Ángeles

    2018-03-12

    Emotional disorders, which include both anxiety and depressive disorders, are the most prevalent psychological disorders according to recent epidemiological studies. Consequently, public costs associated with their treatment have become a matter of concern for public health systems, which face long waiting lists. Because of their high prevalence in the population, finding an effective treatment for emotional disorders has become a key goal of today's clinical psychology. The Unified Protocol for the Transdiagnostic Treatment of Emotional Disorders might serve the aforementioned purpose, as it can be applied to a variety of disorders simultaneously and it can be easily performed in a group format. The study is a multicenter, randomized, non-inferiority controlled clinical trial. Participants will be 220 individuals with emotional disorders, who are randomized to either a treatment as usual (individual cognitive behavioral therapy) or to a Unified Protocol condition in group format. Depression, anxiety, and diagnostic criteria are the primary outcome measures. Secondary measures include the assessment of positive and negative affect, anxiety control, personality traits, overall adjustment, and quality of life. An analysis of treatment satisfaction is also conducted. Assessment points include baseline, post-treatment, and three follow-ups at 3, 6, and 12 months. To control for missing data and possible biases, intention-to-treat and per-protocol analyses will be performed. This is the first randomized, controlled clinical trial to test the effectiveness of a transdiagnostic intervention in a group format for the treatment of emotional disorders in public settings in Spain. Results obtained from this study may have important clinical, social, and economic implications for public mental health settings in Spain. Retrospectively registered at https://clinicaltrials.gov/ . Trial NCT03064477 (March 10, 2017). The trial is active and recruitment is ongoing. Recruitment is expected to finish by January 2020.

  6. Accuracy of a dose-area product compared to an absorbed dose to water at a point in a 2 cm diameter field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dufreneix, S.; Ostrowsky, A.; Rapp, B.

    Purpose: Graphite calorimeters with a core diameter larger than the beam can be used to establish dosimetric references in small fields. The dose-area product (DAP) measured can theoretically be linked to an absorbed dose at a point by the determination of a profile correction. This study aims at comparing the DAP-based protocol to the usual absorbed dose at a point protocol in a 2 cm diameter field for which both references exist. Methods: Two calorimeters were used, respectively, with a sensitive volume of 0.6 cm (for the absorbed dose at a point measurement) and 3 cm diameter (for the DAPmore » measurement). Profile correction was calculated from a 2D dose mapping using three detectors: a PinPoint chamber, a synthetic diamond, and EBT3 films. A specific protocol to read EBT3 films was implemented and the dose-rate and energy dependences were studied to assure a precise measurement, especially in the penumbra and out-of-field regions. Results: EBT3 films were found independent on dose rates over the range studied but showed a strong under-response (18%) at low energies. Depending on the dosimeter used for calculating the profile correction, a deviation of 0.8% (PinPoint chamber), 0.9% (diamond), or 1.9% (EBT3 films) was observed between the calibration coefficient derived from DAP measurements and the one directly established in terms of absorbed dose to water at a point. Conclusions: The DAP method can currently be linked to the classical dosimetric reference system based in an absorbed dose at a point only with a confidence interval of 95% (k = 2). None of the detectors studied can be used to determine an absorbed dose to water at a point from a DAP measurement with an uncertainty smaller than 1.2%.« less

  7. Toward Reliable Lipoprotein Particle Predictions from NMR Spectra of Human Blood: An Interlaboratory Ring Test.

    PubMed

    Monsonis Centelles, Sandra; Hoefsloot, Huub C J; Khakimov, Bekzod; Ebrahimi, Parvaneh; Lind, Mads V; Kristensen, Mette; de Roo, Niels; Jacobs, Doris M; van Duynhoven, John; Cannet, Claire; Fang, Fang; Humpfer, Eberhard; Schäfer, Hartmut; Spraul, Manfred; Engelsen, Søren B; Smilde, Age K

    2017-08-01

    Lipoprotein profiling of human blood by 1 H nuclear magnetic resonance (NMR) spectroscopy is a rapid and promising approach to monitor health and disease states in medicine and nutrition. However, lack of standardization of measurement protocols has prevented the use of NMR-based lipoprotein profiling in metastudies. In this study, a standardized NMR measurement protocol was applied in a ring test performed across three different laboratories in Europe on plasma and serum samples from 28 individuals. Data was evaluated in terms of (i) spectral differences, (ii) differences in LPD predictions obtained using an existing prediction model, and (iii) agreement of predictions with cholesterol concentrations in high- and low-density lipoproteins (HDL and LDL) particles measured by standardized clinical assays. ANOVA-simultaneous component analysis (ASCA) of the ring test spectral ensemble that contains methylene and methyl peaks (1.4-0.6 ppm) showed that 97.99% of the variance in the data is related to subject, 1.62% to sample type (serum or plasma), and 0.39% to laboratory. This interlaboratory variation is in fact smaller than the maximum acceptable intralaboratory variation on quality control samples. It is also shown that the reproducibility between laboratories is good enough for the LPD predictions to be exchangeable when the standardized NMR measurement protocol is followed. With the successful implementation of this protocol, which results in reproducible prediction of lipoprotein distributions across laboratories, a step is taken toward bringing NMR more into scope of prognostic and diagnostic biomarkers, reducing the need for less efficient methods such as ultracentrifugation or high-performance liquid chromatography (HPLC).

  8. Changes in Knee Biomechanics After a Hip-Abductor Strengthening Protocol for Runners With Patellofemoral Pain Syndrome

    PubMed Central

    Ferber, Reed; Kendall, Karen D.; Farr, Lindsay

    2011-01-01

    Abstract Context: Very few authors have investigated the relationship between hip-abductor muscle strength and frontal-plane knee mechanics during running. Objective: To investigate this relationship using a 3-week hip-abductor muscle-strengthening program to identify changes in strength, pain, and biomechanics in runners with patellofemoral pain syndrome (PFPS). Design: Cohort study. Setting: University-based clinical research laboratory. Patients or Other Participants: Fifteen individuals (5 men, 10 women) with PFPS and 10 individuals without PFPS (4 men, 6 women) participated. Intervention(s): The patients with PFPS completed a 3-week hip-abductor strengthening protocol; control participants did not. Main Outcome Measure(s): The dependent variables of interest were maximal isometric hip-abductor muscle strength, 2-dimensional peak knee genu valgum angle, and stride-to-stride knee-joint variability. All measures were recorded at baseline and 3 weeks later. Between-groups differences were compared using repeated-measures analyses of variance. Results: At baseline, the PFPS group exhibited reduced strength, no difference in peak genu valgum angle, and increased stride-to-stride knee-joint variability compared with the control group. After the 3-week protocol, the PFPS group demonstrated increased strength, less pain, no change in peak genu valgum angle, and reduced stride-to-stride knee-joint variability compared with baseline. Conclusions: A 3-week hip-abductor muscle-strengthening protocol was effective in increasing muscle strength and decreasing pain and stride-to-stride knee-joint variability in individuals with PFPS. However, concomitant changes in peak knee genu valgum angle were not observed. PMID:21391799

  9. PROTOCOL FOR EXAMINATION OF THE INNER CAN CLOSURE WELD REGION FOR 3013 DE CONTAINERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mickalonis, J.

    2014-09-16

    The protocol for the examination of the inner can closure weld region (ICCWR) for 3013 DE containers is presented within this report. The protocol includes sectioning of the inner can lid section, documenting the surface condition, measuring corrosion parameters, and storing of samples. This protocol may change as the investigation develops since findings may necessitate additional steps be taken. Details of the previous analyses, which formed the basis for this protocol, are also presented.

  10. High dose microCT does not contribute towards improved microPET/CT image quantitative accuracy and can limit longitudinal scanning of small animals

    NASA Astrophysics Data System (ADS)

    McDougald, Wendy A.; Collins, Richard; Green, Mark; Tavares, Adriana A. S.

    2017-10-01

    Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT) imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1) to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2) to evaluate the absorbed dose associated with varying CT parameters. Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA) software implemented by Mediso. Measured Hounsfield Unit (HU) in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC), uniformity and quantitative bias were also measured. Results: Only less than 2% and 1% of CT acquisition protocols yielded water HU values < -80 and air HU values < -840, respectively. Four out of eleven CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration. Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed towards improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.

  11. Association between organisational and workplace cultures, and patient outcomes: systematic review protocol.

    PubMed

    Braithwaite, J; Herkes, J; Ludlow, K; Lamprell, G; Testa, L

    2016-12-01

    Despite widespread interest in the topic, no current synthesis of research is available analysing the linkages between organisational or workplace cultures on the one hand, and patient outcomes on the other. This protocol proposes a systematic review to analyse and synthesise the literature to date on this topic. The resulting review will discuss characteristics of included studies in terms of the type of healthcare settings researched, the measurements of organisational and workplace culture, patient outcomes measured and the influence of these cultures on patient outcomes. A systematic review will be conducted aiming to examine the associations between organisational and workplace cultures, and patient outcomes, guided by the Preferred Reporting Items for Systematic review and Meta-Analysis Protocols (PRISMA-P) statement. An English language search of abstracts will be executed using the following academic databases: CINAHL, EMBASE, Ovid MEDLINE, Web of Science and PsycINFO. The review will include relevant peer-reviewed articles from randomised controlled trials (RCTs), non-RCTs, controlled before and after studies, interrupted time series studies, cross-sectional analyses, qualitative studies and mixed-method studies. Multiple researchers will be involved in assessing the quality of articles for inclusion in the review. This protocol documents a detailed search strategy, including terms and inclusion criteria, which will form the basis of the subsequent systematic review. Ethics approval is not required as no primary data will be collected. Results will be disseminated through a peer-reviewed publication and conference presentations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Verification for measurement-only blind quantum computing

    NASA Astrophysics Data System (ADS)

    Morimae, Tomoyuki

    2014-06-01

    Blind quantum computing is a new secure quantum computing protocol where a client who does not have any sophisticated quantum technology can delegate her quantum computing to a server without leaking any privacy. It is known that a client who has only a measurement device can perform blind quantum computing [T. Morimae and K. Fujii, Phys. Rev. A 87, 050301(R) (2013), 10.1103/PhysRevA.87.050301]. It has been an open problem whether the protocol can enjoy the verification, i.e., the ability of the client to check the correctness of the computing. In this paper, we propose a protocol of verification for the measurement-only blind quantum computing.

  13. Kinematic changes during running-induced fatigue and relations with core endurance in novice runners.

    PubMed

    Koblbauer, Ian F; van Schooten, Kimberley S; Verhagen, Evert A; van Dieën, Jaap H

    2014-07-01

    This study aimed to investigate kinematic changes experienced during running-induced fatigue. Further, the study examined relations between kinematic changes and core endurance. Repeated measures and correlation. Seventeen novice runners participated in a running-induced fatigue protocol and underwent core endurance assessment. Participants ran at a steady state corresponding to an intensity of 13 on the Borg scale and continued until 2min after a Borg score of 17 or 90% of maximum heart rate was reached. Kinematic data were analyzed for the lower extremities and trunk throughout a running protocol and, on separate days, core endurance measures were recorded. Changes in pre- and post-fatigue running kinematics and their relations with core endurance measures were analyzed. Analysis of peak joint angles revealed significant increases in trunk flexion (4°), decreases in trunk extension (3°), and increases in non-dominant ankle eversion (1.6°) as a result of running-induced fatigue. Post-fatigue increased trunk flexion changes displayed a strong to moderate positive relation with trunk extensor core endurance measures, in contrast to expected negative relations. Novice runners displayed an overall increase in trunk inclination and increased ankle eversion peak angles when fatigued utilizing a running-induced fatigue protocol. As most pronounced changes were found for the trunk, trunk kinematics appear to be significantly affected during fatigued running and should not be overlooked. Core endurance measures displayed unexpected relations with running kinematics and require further investigation to determine the significance of these relations. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. Design, rationale and feasibility of a multidimensional experimental protocol to study early life stress.

    PubMed

    Bartholomeusz, M Dillwyn; Bolton, Philip S; Callister, Robin; Skinner, Virginia; Hodgson, Deborah

    2017-09-01

    There is a rapidly accumulating body of evidence regarding the influential role of early life stress (ELS) upon medical and psychiatric conditions. While self-report instruments, with their intrinsic limitations of recall, remain the primary means of detecting ELS in humans, biological measures are generally limited to a single biological system. This paper describes the design, rationale and feasibility of a study to simultaneously measure neuroendocrine, immune and autonomic nervous system (ANS) responses to psychological and physiological stressors in relation to ELS. Five healthy university students were recruited by advertisement. Exclusion criteria included chronic medical conditions, psychotic disorders, needle phobia, inability to tolerate pain, and those using anti-inflammatory medications. They were clinically interviewed and physiological recordings made over a two-hour period pre, during and post two acute stressors: the cold pressor test and recalling a distressing memory. The Childhood Trauma Questionnaire and the Parental Bonding Index were utilised to measure ELS. Other psychological measures of mood and personality were also administered. Measurements of heart rate, blood pressure, respiratory rate, skin conductance, skin blood flow and temporal plasma samples were successfully obtained before, during and after acute stress. Participants reported the extensive psychological and multisystem physiological data collection and stress provocations were tolerable. Most (4/5) participants indicated a willingness to return to repeat the protocol, indicating acceptability. Our protocol is viable and safe in young physically healthy adults and allows us to assess simultaneously neuroendocrine, immune and autonomic nervous system responses to stressors in persons assessed for ELS.

  15. Dynamic microbubble contrast-enhanced US to measure tumor response to targeted therapy: a proposed clinical protocol with results from renal cell carcinoma patients receiving antiangiogenic therapy.

    PubMed

    Williams, Ross; Hudson, John M; Lloyd, Brendan A; Sureshkumar, Ahthavan R; Lueck, Gordon; Milot, Laurent; Atri, Mostafa; Bjarnason, Georg A; Burns, Peter N

    2011-08-01

    To develop and implement an evidence-based protocol for characterizing vascular response of renal cell carcinoma (RCC) to targeted therapy by using dynamic contrast material-enhanced (DCE) ultrasonography (US). The study was approved by the institutional research ethics board; written informed consent was obtained from all patients. Seventeen patients (four women; median age, 58 years; range, 42-72 years; 13 men, median age, 62 years; range, 45-81 years) with metastatic RCC were examined by using DCE US before and after 2 weeks of treatment with sunitinib (May 2007 to October 2009). Two contrast agent techniques--bolus injection and disruption-replenishment infusion of microbubbles--were compared. Changes in tumor blood velocity and fractional blood volume were measured with both methods, together with reproducibility and effect of compensation for respiratory motion. Tumor changes were assessed with computed tomography, by using the best response with the Response Evaluation Criteria in Solid Tumors (RECIST) and progression-free survival (PFS). Follow-up RECIST measurements were performed at 6-week intervals until progressive disease was detected. In response to treatment, median tumor fractional blood volume measured with the disruption-replenishment infusion method decreased by 73.2% (interquartile range, 46%-87%) (P < .002), with repeated-measure reproducibility of 9%-15%. Significant decreases were also seen with the bolus method, but with poor correlation of changes in bolus peak (r = 0.46, P = .066) and area under the curve (r = 0.47, P = .058), compared with infusion measurements. Changes in DCE US parameters over 2 weeks did not correlate with PFS and could not be used to predict long-term assessment of best response by using RECIST. Follow-up times ranged 28-501 days; the median was 164 days. DCE US provides reproducible and sensitive assessment of vascular changes in response to antiangiogenic therapy. The disruption-replenishment infusion protocol is a flexible method suitable for many tumor types, but further studies are needed to assess whether this protocol may be predictive of patient outcome. © RSNA, 2011.

  16. 3D Computer graphical anatomy study of the femur: a basis for a new nail design.

    PubMed

    Schmutz, Beat; Kmiec, Stanley; Wullschleger, Martin E; Altmann, Martin; Schuetz, Michael

    2017-03-01

    Current intramedullary nails with a radius of curvature (ROC) of 1500-2000 mm sometimes cause distal anterior cortical encroachment. Furthermore, clinical data indicate that the proximal nail end is too long for some Asian patients. The objective of our study was to develop a comprehensive 3D measurement protocol that measures both the anatomy of the canal and the proximal region. The protocol was used to obtain measurements from Caucasian and Asian (Japanese and Thai) specimens. A total of 90 3D bone models representative of hip fracture patients were reconstructed from CT data. RapidForm 2006 was used to generate the reference geometries required for determining radius and angulation of shaft antecurvature as well as measurements of the proximal anatomy. Multiple linear regression analyses were used to determine the relative contribution of height, age, ethnicity, gender, and body side on the total variance. The mean ROC in the natural 3D antecurvature plane was 885 mm overall, 974 mm in Caucasians and 787 mm in Asians. Height, age, ethnicity, gender, and body side significantly predicted ROC (R = 0.53, p = 0.000). The mean values of anteversion measurements for Asians (Japanese: 22.1°; Thai: 22.7°) were significantly larger than those of the Caucasians (14.5°; p = 0.001). There was virtually no difference (p = 0.186) between the measurements pertaining to the length of the proximal nail end between Caucasian and Asian samples. There was no significant difference between the mean neck-to-shaft angles (Caucasian: 126°; Japanese: 128.2°; Thai: 125.7°; p = 0.198 for Asians vs Caucasians). The developed comprehensive anatomical 3D measurement protocol could serve as standardised approach for anthropometric studies in the future. Our data suggest that the ROC of current nail designs should be reduced from between 1500 and 2000 to 1000 mm to achieve an improved fit for the investigated population.

  17. Thermal/Optical Methods for Elemental Carbon Quantification in Soils and Urban Dusts: Equivalence of Different Analysis Protocols

    PubMed Central

    Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng

    2013-01-01

    Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method. PMID:24358286

  18. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 1; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, James L. (Editor); Fargion, Giulietta (Editor); Mueller, J. L.; Trees, C.; Austin, R. W.; Pietras, C.; Hooker, S.; Holben, B.; McClain, Charles R.; Clark, D. K.; hide

    2002-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the SIMBIOS Project. It supersedes the earlier version, and is organized into four parts: Introductory Background, Instrument Characteristics, Field Measurements and Data Analysis, Data Reporting and Archival. Changes in this revision include the addition of three new chapters: (1) Fundamental Definitions, Relationships and Conventions; (2) MOBY, A Radiometric Buoy for Performance Monitoring and Vicarious Calibration of Satellite Ocean Color Sensors: Measurement and Data Analysis Protocols; and (3) Normalized Water-Leaving Radiance and Remote Sensing Reflectance: Bidirectional Reflectance and Other Factors. Although the present document represents another significant, incremental improvement in the ocean optics protocols, there are several protocols that have either been overtaken by recent technological progress, or have been otherwise identified as inadequate. Revision 4 is scheduled for completion sometime in 2003. This technical report is not meant as a substitute for scientific literature. Instead, it will provide a ready and responsive vehicle for the multitude of technical reports issued by an operational Project. The contributions are published as submitted, after only minor editing to correct obvious grammatical or clerical errors.

  19. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 2; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, James L. (Editor); Fargion, Giulietta S. (Editor); Trees, C.; Austin, R. W.; Pietras, C. (Editor); Hooker, S.; Holben, B.; McClain, Charles R.; Clark, D. K.; Yuen, M.

    2002-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the SIMBIOS Project. It supersedes the earlier version, and is organized into four parts: Introductory Background, Instrument Characteristics, Field Measurements and Data Analysis, Data Reporting and Archival. Changes in this revision include the addition of three new chapters: (1) Fundamental Definitions, Relationships and Conventions; (2) MOBY, A Radiometric Buoy for Performance Monitoring and Vicarious Calibration of Satellite Ocean Color Sensors: Measurement and Data Analysis Protocols; and (3) Normalized Water-Leaving Radiance and Remote Sensing Reflectance: Bidirectional Reflectance and Other Factors. Although the present document represents another significant, incremental improvement in the ocean optics protocols, there are several protocols that have either been overtaken by recent technological progress, or have been otherwise identified as inadequate. Revision 4 is scheduled for completion sometime in 2003. This technical report is not meant as a substitute for scientific literature. Instead, it will provide a ready and responsive vehicle for the multitude of technical reports issued by an operational Project. The contributions are published as submitted, after only minor editing to correct obvious grammatical or clerical errors.

  20. Soil sampling and analytical strategies for mapping fallout in nuclear emergencies based on the Fukushima Dai-ichi Nuclear Power Plant accident.

    PubMed

    Onda, Yuichi; Kato, Hiroaki; Hoshi, Masaharu; Takahashi, Yoshio; Nguyen, Minh-Long

    2015-01-01

    The Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident resulted in extensive radioactive contamination of the environment via deposited radionuclides such as radiocesium and (131)I. Evaluating the extent and level of environmental contamination is critical to protecting citizens in affected areas and to planning decontamination efforts. However, a standardized soil sampling protocol is needed in such emergencies to facilitate the collection of large, tractable samples for measuring gamma-emitting radionuclides. In this study, we developed an emergency soil sampling protocol based on preliminary sampling from the FDNPP accident-affected area. We also present the results of a preliminary experiment aimed to evaluate the influence of various procedures (e.g., mixing, number of samples) on measured radioactivity. Results show that sample mixing strongly affects measured radioactivity in soil samples. Furthermore, for homogenization, shaking the plastic sample container at least 150 times or disaggregating soil by hand-rolling in a disposable plastic bag is required. Finally, we determined that five soil samples within a 3 m × 3-m area are the minimum number required for reducing measurement uncertainty in the emergency soil sampling protocol proposed here. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Oxygen Reduction Reaction Measurements on Platinum Electrocatalysts Utilizing Rotating Disk Electrode Technique: I. Impact of Impurities, Measurement Protocols and Applied Corrections

    DOE PAGES

    Shinozaki, Kazuma; Zack, Jason W.; Richards, Ryan M.; ...

    2015-07-22

    The rotating disk electrode (RDE) technique is being extensively used as a screening tool to estimate the activity of novel PEMFC electrocatalysts synthesized in lab-scale (mg) quantities. Discrepancies in measured activity attributable to glassware and electrolyte impurity levels, as well as conditioning, protocols and corrections are prevalent in the literature. Moreover, the electrochemical response to a broad spectrum of commercially sourced perchloric acid and the effect of acid molarity on impurity levels and solution resistance were also assessed. Our findings reveal that an area specific activity (SA) exceeding 2.0 mA/cm 2 (20 mV/s, 25°C, 100 kPa, 0.1 M HClO 4)more » for polished poly-Pt is an indicator of impurity levels that do not impede the accurate measurement of the ORR activity of Pt based catalysts. After exploring various conditioning protocols to approach maximum utilization of the electrochemical area (ECA) and peak ORR activity without introducing catalyst degradation, an investigation of measurement protocols for ECA and ORR activity was conducted. Down-selected protocols were based on the criteria of reproducibility, duration of experiments, impurity effects and magnitude of pseudo-capacitive background correction. In sum, statistical reproducibility of ORR activity for poly-Pt and Pt supported on high surface area carbon was demonstrated.« less

  2. Radiation safety protocol using real-time dose reporting reduces patient exposure in pediatric electrophysiology procedures.

    PubMed

    Patel, Akash R; Ganley, Jamie; Zhu, Xiaowei; Rome, Jonathan J; Shah, Maully; Glatz, Andrew C

    2014-10-01

    Radiation exposure during pediatric catheterization is significant. We sought to describe radiation exposure and the effectiveness of radiation safety protocols in reducing exposure during catheter ablations with electrophysiology studies in children and patients with congenital heart disease. We additionally sought to identify at-risk patients. We retrospectively reviewed all interventional electrophysiology procedures performed from April 2009 to September 2011 (6 months preceding intervention, 12 months following implementation of initial radiation safety protocol, and 8 months following implementation of modified protocol). The protocols consisted of low pulse rate fluoroscopy settings, operator notification of skin entrance dose every 1,000 mGy, adjusting cameras by >5 at every 1,000 mGy, and appropriate collimation. The cohort consisted of 291 patients (70 pre-intervention, 137 after initial protocol implementation, 84 after modified protocol implementation) at a median age of 14.9 years with congenital heart disease present in 11 %. Diagnoses included atrioventricular nodal reentrant tachycardia (25 %), atrioventricular reentrant tachycardia (61 %), atrial tachycardias (12 %), and ventricular tachycardia (2 %). There were no differences between groups based on patient, arrhythmia, and procedural characteristics. Following implementation of the protocols, there were significant reductions in all measures of radiation exposure: fluoroscopy time (17.8 %), dose area product (80.2 %), skin entry dose (81.0 %), and effective dose (76.9 %), p = 0.0001. Independent predictors of increased radiation exposure included larger patient weight, longer fluoroscopy time, and lack of radiation safety protocol. Implementation of a radiation safety protocol for pediatric and congenital catheter ablations can drastically reduce radiation exposure to patients without affecting procedural success.

  3. Chapter 22: Compressed Air Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Benton, Nathanael; Burns, Patrick

    Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: High-efficiency/variable speed drive (VSD) compressormore » replacing modulating, load/unload, or constant-speed compressor; and Compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.« less

  4. A Fatigue Measuring Protocol for Wireless Body Area Sensor Networks.

    PubMed

    Akram, Sana; Javaid, Nadeem; Ahmad, Ashfaq; Khan, Zahoor Ali; Imran, Muhammad; Guizani, Mohsen; Hayat, Amir; Ilahi, Manzoor

    2015-12-01

    As players and soldiers preform strenuous exercises and do difficult and tiring duties, they are usually the common victims of muscular fatigue. Keeping this in mind, we propose FAtigue MEasurement (FAME) protocol for soccer players and soldiers using in-vivo sensors for Wireless Body Area Sensor Networks (WBASNs). In FAME, we introduce a composite parameter for fatigue measurement by setting a threshold level for each sensor. Whenever, any sensed data exceeds its threshold level, the players or soldiers are declared to be in a state of fatigue. Moreover, we use a vibration pad for the relaxation of fatigued muscles, and then utilize the vibrational energy by means of vibration detection circuit to recharge the in-vivo sensors. The induction circuit achieves about 68 % link efficiency. Simulation results show better performance of the proposed FAME protocol, in the chosen scenarios, as compared to an existing Wireless Soccer Team Monitoring (WSTM) protocol in terms of the selected metrics.

  5. Robowell: An automated process for monitoring ground water quality using established sampling protocols

    USGS Publications Warehouse

    Granato, G.E.; Smith, K.P.

    1999-01-01

    Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

  6. Intercomparison of thermal-optical method with different temperature protocols: Implications from source samples and solvent extraction

    NASA Astrophysics Data System (ADS)

    Cheng, Yuan; Duan, Feng-kui; He, Ke-bin; Du, Zhen-yu; Zheng, Mei; Ma, Yong-liang

    2012-12-01

    Three temperature protocols with different peak inert mode temperature (Tpeak-inert) were compared based on source and ambient samples (both untreated and extracted using a mixture of hexane, methylene chloride, and acetone) collected in Beijing, China. The ratio of EC580 (elemental carbon measured by the protocol with a Tpeak-inert of 580 °C; similar hereinafter) to EC850 could be as high as 4.8 for biomass smoke samples whereas the ratio was about 1.0 for diesel and gasoline exhaust samples. The EC580 to EC850 ratio averaged 1.95 ± 0.89 and 1.13 ± 0.20 for the untreated and extracted ambient samples, whereas the EC580 to EC650 ratio of ambient samples was 1.22 ± 0.10 and 1.20 ± 0.12 before and after extraction. It was suggested that there are two competing mechanisms for the effects of Tpeak-inert on the EC results such that when Tpeak-inert is increased, one mechanism tends to decrease EC by increasing the amount of charring whereas the other tends to increase EC through promoting more charring to evolve before native EC. Results from this study showed that EC does not always decrease when increasing the peak inert mode temperature. Moreover, reducing the charring amount could improve the protocols agreement on EC measurements, whereas temperature protocol would not influence the EC results if no charring is formed. This study also demonstrated the benefits of allowing for the OC and EC split occurring in the inert mode when a high Tpeak-inert is used (e.g., 850 °C).

  7. The best of both worlds: Building on the COPUS and RTOP observation protocols to easily and reliably measure various levels of reformed instructional practice.

    PubMed

    Lund, Travis J; Pilarz, Matthew; Velasco, Jonathan B; Chakraverty, Devasmita; Rosploch, Kaitlyn; Undersander, Molly; Stains, Marilyne

    2015-01-01

    Researchers, university administrators, and faculty members are increasingly interested in measuring and describing instructional practices provided in science, technology, engineering, and mathematics (STEM) courses at the college level. Specifically, there is keen interest in comparing instructional practices between courses, monitoring changes over time, and mapping observed practices to research-based teaching. While increasingly common observation protocols (Reformed Teaching Observation Protocol [RTOP] and Classroom Observation Protocol in Undergraduate STEM [COPUS]) at the postsecondary level help achieve some of these goals, they also suffer from weaknesses that limit their applicability. In this study, we leverage the strengths of these protocols to provide an easy method that enables the reliable and valid characterization of instructional practices. This method was developed empirically via a cluster analysis using observations of 269 individual class periods, corresponding to 73 different faculty members, 28 different research-intensive institutions, and various STEM disciplines. Ten clusters, called COPUS profiles, emerged from this analysis; they represent the most common types of instructional practices enacted in the classrooms observed for this study. RTOP scores were used to validate the alignment of the 10 COPUS profiles with reformed teaching. Herein, we present a detailed description of the cluster analysis method, the COPUS profiles, and the distribution of the COPUS profiles across various STEM courses at research-intensive universities. © 2015 T. J. Lund et al. CBE—Life Sciences Education © 2015 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  8. A Pediatric Intensive Care Unit Bedside Computer Clinical Decision Support Protocol for Hyperglycemia Is Feasible, Safe and Offers Advantages

    PubMed Central

    Lanspa, Michael J.; Wilson, Emily L.; Sward, Katherine A.; Jephson, Al; Larsen, Gitte Y.; Morris, Alan H.

    2017-01-01

    Abstract Background: Computer clinical decision support (CDS) systems are uncommon in the pediatric intensive care unit (PICU), despite evidence suggesting they improve outcomes in adult ICUs. We reasoned that a bedside CDS protocol for intravenous insulin titration, eProtocol-insulin, would be feasible and safe in critically ill children. Methods: We retrospectively reviewed data from non-diabetic children admitted to the PICU with blood glucose (BG) ≥140 mg/dL who were managed with intravenous insulin by either unaided clinician titration or eProtocol-insulin. Primary outcomes were BG measurements in target range (80–110 mg/dL) and severe hypoglycemia (BG ≤40 mg/dL); secondary outcomes were 60-day mortality and PICU length of stay. We assessed bedside nurse satisfaction with the eProtocol-insulin protocol by using a 5-point Likert scale and measured clinician compliance with eProtocol-insulin recommendations. Results: Over 5 years, 69 children were titrated with eProtocol-insulin versus 104 by unaided clinicians. eProtocol-insulin achieved target range more frequently than clinician titration (41% vs. 32%, P < 0.001). Severe hypoglycemia was uncommon in both groups (4.3% of patients in eProtocol-insulin, 8.7% in clinician titration, P = 0.37). There were no differences in mean time to BG target or median BG between the groups. Mortality was 23% in both groups. Clinician compliance with eProtocol-insulin recommendations was 89%. Nurses believed that eProtocol-insulin was easy to understand and safer than clinician titration. Conclusions: eProtocol-insulin is safe for titration of intravenous insulin in critically ill children. Clinical research protocols and quality improvement initiatives aimed at optimizing BG control should utilize detailed computer protocols that enable replicable clinician decisions. PMID:28248127

  9. Measurement device-independent quantum dialogue

    NASA Astrophysics Data System (ADS)

    Maitra, Arpita

    2017-12-01

    Very recently, the experimental demonstration of quantum secure direct communication (QSDC) with state-of-the-art atomic quantum memory has been reported (Zhang et al. in Phys Rev Lett 118:220501, 2017). Quantum dialogue (QD) falls under QSDC where the secrete messages are communicated simultaneously between two legitimate parties. The successful experimental demonstration of QSDC opens up the possibilities for practical implementation of QD protocols. Thus, it is necessary to analyze the practical security issues of QD protocols for future implementation. Since the very first proposal for QD by Nguyen (Phys Lett A 328:6-10, 2004), a large number of variants and extensions have been presented till date. However, all of those leak half of the secret bits to the adversary through classical communications of the measurement results. In this direction, motivated by the idea of Lo et al. (Phys Rev Lett 108:130503, 2012), we propose a measurement device-independent quantum dialogue scheme which is resistant to such information leakage as well as side-channel attacks. In the proposed protocol, Alice and Bob, two legitimate parties, are allowed to prepare the states only. The states are measured by an untrusted third party who may himself behave as an adversary. We show that our protocol is secure under this adversarial model. The current protocol does not require any quantum memory, and thus, it is inherently robust against memory attacks. Such robustness might not be guaranteed in the QSDC protocol with quantum memory (Zhang et al. 2017).

  10. Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Crawford, Alasdair J.; Fuller, Jason

    This Protocol provides a set of “best practices” for characterizing energy storage systems (ESSs) and measuring and reporting their performance. It serves as a basis for assessing how an ESS will perform with respect to key performance attributes relevant to different applications. It is intended to provide a valid and accurate basis for the comparison of different ESSs. By achieving the stated purpose, the Protocol will enable more informed decision-making in the selection of ESSs for various stationary applications. The Protocol identifies general information and technical specifications relevant in describing an ESS and also defines a set of test, measurement,more » and evaluation criteria with which to express the performance of ESSs that are intended for energy-intensive and/or power-intensive stationary applications. An ESS includes a storage device, battery management system, and any power conversion systems installed with the storage device. The Protocol is agnostic with respect to the storage technology and the size and rating of the ESS. The Protocol does not apply to single-use storage devices and storage devices that are not coupled with power conversion systems, nor does it address safety, security, or operations and maintenance of ESSs, or provide any pass/fail criteria.« less

  11. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    NASA Technical Reports Server (NTRS)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  12. A randomized controlled pilot study feasibility of a tablet-based guided audio-visual relaxation intervention for reducing stress and pain in adults with sickle cell disease.

    PubMed

    Ezenwa, Miriam O; Yao, Yingwei; Engeland, Christopher G; Molokie, Robert E; Wang, Zaijie Jim; Suarez, Marie L; Wilkie, Diana J

    2016-06-01

    To test feasibility of a guided audio-visual relaxation intervention protocol for reducing stress and pain in adults with sickle cell disease. Sickle cell pain is inadequately controlled using opioids, necessitating further intervention such as guided relaxation to reduce stress and pain. Attention-control, randomized clinical feasibility pilot study with repeated measures. Randomized to guided relaxation or control groups, all patients recruited between 2013-2014 during clinical visits, completed stress and pain measures via a Galaxy Internet-enabled Android tablet at the Baseline visit (pre/post intervention), 2-week posttest visit and also daily at home between the two visits. Experimental group patients were asked to use a guided relaxation intervention at the Baseline visit and at least once daily for 2 weeks. Control group patients engaged in a recorded sickle cell discussion at the Baseline visit. Data were analysed using linear regression with bootstrapping. At baseline, 27/28 of consented patients completed the study protocol. Group comparison showed that guided relaxation significantly reduced current stress and pain. At the 2-week posttest, 24/27 of patients completed the study, all of whom reported liking the study. Patients completed tablet-based measures on 71% of study days (69% in control group, 72% in experiment group). At the 2-week posttest, the experimental group had significantly lower composite pain index scores, but the two groups did not differ significantly on stress intensity. This study protocol appears feasible. The tablet-based guided relaxation intervention shows promise for reducing sickle cell pain and warrants a larger efficacy trial. The ClinicalTrials.gov Identifier is: NCT02501447. © 2016 John Wiley & Sons Ltd.

  13. Assessment protocols of maximum oxygen consumption in young people with Down syndrome--a review.

    PubMed

    Seron, Bruna Barboza; Greguol, Márcia

    2014-03-01

    Maximum oxygen consumption is considered the gold standard measure of cardiorespiratory fitness. Young people with Down syndrome (DS) present low values of this indicator compared to their peers without disabilities and to young people with an intellectual disability but without DS. The use of reliable and valid assessment methods provides more reliable results for the diagnosis of cardiorespiratory fitness and the response of this variable to exercise. The aim of the present study was to review the literature on the assessment protocols used to measure maximum oxygen consumption in children and adolescents with Down syndrome giving emphasis to the protocols used, the validation process and their feasibility. The search was carried out in eight electronic databases--Scopus, Medline-Pubmed, Web of science, SportDiscus, Cinhal, Academic Search Premier, Scielo, and Lilacs. The inclusion criteria were: (a) articles which assessed VO2peak and/or VO2max (independent of the validation method), (b) samples composed of children and/or adolescents with Down syndrome, (c) participants of up to 20 years old, and (d) studies performed after 1990. Fifteen studies were selected and, of these, 11 measured the VO2peak using tests performed in a laboratory, 2 used field tests and the remaining 2 used both laboratory and field tests. The majority of the selected studies used maximal tests and conducted familiarization sessions. All the studies took into account the clinical conditions that could hamper testing or endanger the individuals. However, a large number of studies used tests which had not been specifically validated for the evaluated population. Finally, the search emphasized the small number of studies which use field tests to evaluate oxygen consumption. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Research and Teaching: A New Tool for Measuring Student Behavioral Engagement in Large University Classes

    ERIC Educational Resources Information Center

    Lane, Erin S.; Harris, Sara E.

    2015-01-01

    The authors developed a classroom observation protocol for quantitatively measuring student engagement in large university classes. The Behavioral Engagement Related to instruction (BERI) protocol can be used to provide timely feedback to instructors as to how they can improve student engagement in their classrooms.

  15. Effect of prophylactic polishing protocols on the surface roughness of esthetic restorative materials.

    PubMed

    Neme, A L; Frazier, K B; Roeder, L B; Debner, T L

    2002-01-01

    Many polishing protocols have been evaluated in vitro for their effect on the surface roughness of restorative materials. These results have been useful in establishing protocols for in vivo application. However, limited research has focused on the subsequent care and maintenance of esthetic restorations following their placement. This investigation evaluated the effect of five polishing protocols that could be implemented at recall on the surface roughness of five direct esthetic restorative materials. Specimens (n=25) measuring 8 mm diameter x 3 mm thick were fabricated in an acrylic mold using five light-cured resin-based materials (hybrid composite, microfilled composite, packable composite, compomer and resin-modified glass ionomer). After photopolymerization, all specimens were polished with Sof-Lex Disks to produce an initial (baseline) surface finish. All specimens were then polished with one of five prophylactic protocols (Butler medium paste, Butler coarse paste, OneGloss, SuperBuff or OneGloss & SuperBuff). The average surface roughness of each treated specimen was determined from three measurements with a profilometer (Surface 1). Next, all specimens were brushed 60,000 times at 1.5 Hz using a brush-head force of 2 N on a Manly V-8 cross-brushing machine in a 50:50 (w/w) slurry of toothpaste and water. The surface roughness of each specimen was measured after brushing (Surface 2) followed by re-polishing with one of five protocols, then final surface roughness values were determined (Surface 3). The data were analyzed using repeated measures ANOVA. Significant differences (p=0.05) in surface roughness were observed among restorative materials and polishing protocols. The microfilled and hybrid resin composite yielded significantly rougher surfaces than the other three materials following tooth brushing. Prophylactic polishing protocols can be used to restore a smooth surface on resin-based esthetic restorative materials following simulated tooth brushing.

  16. Chapter 1: Introduction. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Michael; Haeri, Hossein; Reynolds, Arlis

    This chapter provides a set of model protocols for determining energy and demand savings that result from specific energy efficiency measures implemented through state and utility efficiency programs. The methods described here are approaches that are or are among the most commonly used and accepted in the energy efficiency industry for certain measures or programs. As such, they draw from the existing body of research and best practices for energy efficiency program evaluation, measurement, and verification (EM&V). These protocols were developed as part of the Uniform Methods Project (UMP), funded by the U.S. Department of Energy (DOE). The principal objectivemore » for the project was to establish easy-to-follow protocols based on commonly accepted methods for a core set of widely deployed energy efficiency measures.« less

  17. Quantum key distribution with prepare-and-measure Bell test

    PubMed Central

    Tan, Yong-gang

    2016-01-01

    The prepare-and-measure quantum key distribution (QKD) has the merits of fast speed, high key generation rate, and easy implementation. However, the detector side channel attacks greatly undermine the security of the key bits. The eavesdropper, Eve, exploits the flaws of the detectors to obtain illegal information without violating quantum principles. It means that she can intervene in the communication without being detected. A prepare-and-measure Bell test protocol will be proposed. By randomly carrying out Bell test at the side of the information receiver, Bob, Eve’s illegal information gain within the detector side channel attack can be well bounded. This protocol does not require any improvement on the detectors used in available prepare-and-measure QKD. Though we only illustrate its application in the BB84 protocol, it is applicable for any prepare-and-measure QKD. PMID:27733771

  18. Impact of body size, nutrition and socioeconomic position in early life on the epigenome: a systematic review protocol.

    PubMed

    Maddock, Jane; Wulaningsih, Wahyu; Hardy, Rebecca

    2017-07-05

    Body size, nutrition and socioeconomic position (SEP) in early life have been associated with a range of later life health outcomes. Epigenetic regulation is one mechanism through which these early life factors may impact later life health. The aim of this review protocol is to outline procedures to document the influence of body size, nutrition and SEP in early life on the epigenome. MEDLINE, Embase and BIOSIS will be systematically searched using pre-defined keywords. Additional studies will be identified through manual searching of reference lists. Two independent researchers will assess the eligibility and quality of each study, with disagreements being resolved through discussion or a third reviewer. Studies will be included if they have epigenetic markers measured either at the same time as, or after, the early life exposure and, have a measure of body size, nutrition or SEP in early life (up to 12 years), are in the English language and are from a sample of community-dwelling participants. This protocol will be used to collate the evidence for the effect of early life factors on the epigenome. Findings will form a component of a wider research study examining epigenetic responses to exposures in early life and over the life course and its impact on healthy ageing using data from population-based cohort studies. PROSPERO CRD42016050193.

  19. Cognitive-behavioral group treatment for social phobia in adolescents. A preliminary study.

    PubMed

    Albano, A M; Marten, P A; Holt, C S; Heimberg, R G; Barlow, D H

    1995-10-01

    The present study is a preliminary evaluation of the effectiveness of a new cognitive-behavioral group treatment protocol for social phobia in adolescents. Five adolescents with social phobia were treated in a 16-session group treatment program, with parental involvement in selected sessions. Treatment involved skills training (social skills, problem solving, assertiveness), cognitive restructuring, behavioral exposure, and homework. Self-report measures of anxiety and depression, taken throughout treatment, indicated significant improvements over a 1-year follow-up period. Behavior test measures also indicated a decrease in subjective anxiety ratings after treatment which was maintained at follow-up. Structured diagnostic interviews 1 year after treatment confirmed full remission of social phobia for four subjects, with one subject's phobia in partial remission. Overall, the present findings support the continued evaluation of this protocol for social phobic adolescents.

  20. Telehealth: voice therapy using telecommunications technology.

    PubMed

    Mashima, Pauline A; Birkmire-Peters, Deborah P; Syms, Mark J; Holtel, Michael R; Burgess, Lawrence P A; Peters, Leslie J

    2003-11-01

    Telehealth offers the potential to meet the needs of underserved populations in remote regions. The purpose of this study was a proof-of-concept to determine whether voice therapy can be delivered effectively remotely. Treatment outcomes were evaluated for a vocal rehabilitation protocol delivered under 2 conditions: with the patient and clinician interacting within the same room (conventional group) and with the patient and clinician in separate rooms, interacting in real time via a hard-wired video camera and monitor (video teleconference group). Seventy-two patients with voice disorders served as participants. Based on evaluation by otolaryngologists, 31 participants were diagnosed with vocal nodules, 29 were diagnosed with edema, 9 were diagnosed with unilateral vocal fold paralysis, and 3 presented with vocal hyperfunction with no laryngeal pathology. Fifty-one participants (71%) completed the vocal rehabilitation protocol. Outcome measures included perceptual judgments of voice quality, acoustic analyses of voice, patient satisfaction ratings, and fiber-optic laryngoscopy. There were no differences in outcome measures between the conventional group and the remote video teleconference group. Participants in both groups showed positive changes on all outcome measures after completing the vocal rehabilitation protocol. Reasons for participants discontinuing therapy prematurely provided support for the telehealth model of service delivery.

  1. Quantum Tomography Protocols with Positivity are Compressed Sensing Protocols (Open Access)

    DTIC Science & Technology

    2015-12-08

    ARTICLE OPEN Quantum tomography protocols with positivity are compressed sensing protocols Amir Kalev1, Robert L Kosut2 and Ivan H Deutsch1...Characterising complex quantum systems is a vital task in quantum information science. Quantum tomography, the standard tool used for this purpose, uses a well...designed measurement record to reconstruct quantum states and processes. It is, however, notoriously inefficient. Recently, the classical signal

  2. Ramped-rate vs continuous-rate infusions: An in vitro comparison of convection enhanced delivery protocols.

    PubMed

    Schomberg, Dominic; Wang, Anyi; Marshall, Hope; Miranpuri, Gurwattan; Sillay, Karl

    2013-04-01

    Convection enhanced delivery (CED) is a technique using infusion convection currents to deliver therapeutic agents into targeted regions of the brain. Recently, CED is gaining significant acceptance for use in gene therapy of Parkinson's disease (PD) employing direct infusion into the brain. CED offers advantages in that it targets local areas of the brain, bypasses the blood-brain barrier (BBB), minimizes systemic toxicity of the therapeutics, and allows for delivery of larger molecules that diffusion driven methods cannot achieve. Investigating infusion characteristics such as backflow and morphology is important in developing standard and effective protocols in order to successfully deliver treatments into the brain. Optimizing clinical infusion protocols may reduce backflow, improve final infusion cloud morphology, and maximize infusate penetrance into targeted tissue. The purpose of the current study was to compare metrics during ramped-rate and continuous-rate infusions using two different catheters in order to optimize current infusion protocols. Occasionally, the infusate refluxes proximally up the catheter tip, known as backflow, and minimizing this can potentially reduce undesirable effects in the clinical setting. Traditionally, infusions are performed at a constant rate throughout the entire duration, and backflow is minimized only by slow infusion rates, which increases the time required to deliver the desired amount of infusate. In this study, we investigate the effects of ramping and various infusion rates on backflow and infusion cloud morphology. The independent parameters in the study are: ramping, maximum infusion rate, time between rate changes, and increments of rate changes. Backflow was measured using two methods: i) at the point of pressure stabilization within the catheter, and ii) maximum backflow as shown by video data. Infusion cloud morphology was evaluated based on the height-to-width ratio of each infusion cloud at the end of each experiment. Results were tabulated and statistically analyzed to identify any significant differences between protocols. The experimental results show that CED rampedrate infusion protocols result in smaller backflow distances and more spherical cloud morphologies compared to continuous-rate infusion protocols ending at the same maximum infusion rate. Our results also suggest internal-line pressure measurements can approximate the time-point at which backflow ceases. Our findings indicate that ramping CED infusion protocols can potentially minimize backflow and produce more spherical infusion clouds. However, further research is required to determine the strength of this correlation, especially in relation to maximum infusion rates.

  3. Effects of exercise continued until anaerobic threshold on balance performance in male basketball players.

    PubMed

    Erkmen, Nurtekin; Suveren, Sibel; Göktepe, Ahmet Salim

    2012-06-01

    The objective of the present study was to determine the effects of exercise continued until the anaerobic threshold on balance performance in basketball players. Twelve male basketball players (age = 20.92 ± 2.81 years, body height = 192.72 ± 7.61 cm, body mass = 88.09 ± 8.41 kg, training experience = 7.17 ± 3.10 years) volunteered to participate in this study. A Kinesthetic Ability Trainer (KAT 2000 stabilometer) was used to measure the balance performance. Balance tests consisted of static tests on dominant, nondominant and double leg stance. The Bruce Protocol was performed by means of a treadmill. The exercise protocol was terminated when the subject passed the anaerobic threshold. After the exercise protocol, balance measurements were immediately repeated. Statistical differences between pre and post-exercise for dominant, nondominant and double leg stance were determined by the paired samples t-test according to the results of the test of normality. The post-exercise balance score on the dominant leg was significantly higher than pre-exercise (t = -2.758, p < 0.05). No differences existed between pre- and post-exercise in the balance scores of the nondominant leg after the exercise protocol (t = 0.428, p > 0.05). A significant difference was found between pre and post-exercise balance scores in the double leg stance (t = -2.354, p < 0.05). The main finding of this study was that an incremental exercise continued until the anaerobic threshold decreased balance performance on the dominant leg in basketball players, but did not alter it in the nondominant leg.

  4. Quantum secret information equal exchange protocol based on dense coding

    NASA Astrophysics Data System (ADS)

    Jiang, Ying-Hua; Zhang, Shi-Bin; Dai, Jin-Qiao; Shi, Zhi-Ping

    2018-04-01

    In this paper, we design a novel quantum secret information equal exchange protocol, which implements the equal exchange of secret information between the two parties with the help of semi-trusted third party (TP). In the protocol, EPR pairs prepared by the TP are, respectively, distributed to both the communication parties. Then, the two parties perform Pauli operation on each particle and return the new particles to TP, respectively. TP measures each new pair with Bell basis and announces the measurement results. Both parties deduce the secret information of each other according to the result of announcement by TP. Finally, the security analysis shows that this protocol solves the problem about equal exchange of secret information between two parties and verifies the security of semi-trusted TPs. It proves that the protocol can effectively resist glitch attacks, intercept retransmission attacks and entanglement attack.

  5. A protocol for evaluating video trackers under real-world conditions.

    PubMed

    Nawaz, Tahir; Cavallaro, Andrea

    2013-04-01

    The absence of a commonly adopted performance evaluation framework is hampering advances in the design of effective video trackers. In this paper, we present a single-score evaluation measure and a protocol to objectively compare trackers. The proposed measure evaluates tracking accuracy and failure, and combines them for both summative and formative performance assessment. The proposed protocol is composed of a set of trials that evaluate the robustness of trackers on a range of test scenarios representing several real-world conditions. The protocol is validated on a set of sequences with a diversity of targets (head, vehicle and person) and challenges (occlusions, background clutter, pose changes and scale changes) using six state-of-the-art trackers, highlighting their strengths and weaknesses on more than 187000 frames. The software implementing the protocol and the evaluation results are made available online and new results can be included, thus facilitating the comparison of trackers.

  6. Extraction Protocols for Individual Zebrafish's Ventricle Myosin and Skeletal Muscle Actin for In vitro Motility Assays

    PubMed Central

    Scheid, Lisa-Mareike; Weber, Cornelia; Bopp, Nasrin; Mosqueira, Matias; Fink, Rainer H. A.

    2017-01-01

    The in vitro motility assay (IVMA) is a technique that enables the measurement of the interaction between actin and myosin providing a relatively simple model to understand the mechanical muscle function. For actin-myosin IVMA, myosin is immobilized in a measurement chamber, where it converts chemical energy provided by ATP hydrolysis into mechanical energy. The result is the movement of fluorescently labeled actin filaments that can be recorded microscopically and analyzed quantitatively. Resulting sliding speeds and patterns help to characterize the underlying actin-myosin interaction that can be affected by different factors such as mutations or active compounds. Additionally, modulatory actions of the regulatory proteins tropomyosin and troponin in the presence of calcium on actin-myosin interaction can be studied with the IVMA. Zebrafish is considered a suitable model organism for cardiovascular and skeletal muscle research. In this context, straightforward protocols for the isolation and use of zebrafish muscle proteins in the IVMA would provide a useful tool in molecular studies. Currently, there are no protocols available for the mentioned purpose. Therefore, we developed fast and easy protocols for characterization of zebrafish proteins in the IVMA. Our protocols enable the interested researcher to (i) isolate actin from zebrafish skeletal muscle and (ii) extract functionally intact myosin from cardiac and skeletal muscle of individual adult zebrafish. Zebrafish tail muscle actin is isolated after acetone powder preparation, polymerized, and labeled with Rhodamine-Phalloidin. Myosin from ventricles of adult zebrafish is extracted directly into IVMA flow-cells. The same extraction protocol is applicable for comparably small tissue pieces as from zebrafish tail, mouse and frog muscle. After addition of the fluorescently labeled F-actin from zebrafish—or other origin—and ATP, sliding movement can be visualized using a fluorescence microscope and an intensified CCD camera. Taken together, we introduce a method for functional analysis in zebrafish cardiac and skeletal muscle research to study mutations at the molecular level of thick or thin filament proteins. Additionally, preliminary data indicate the usefulness of the presented method to perform the IVMA with myosin extracted from muscles of other animal models. PMID:28620318

  7. Cheating and Anti-Cheating in Gossip-Based Protocol: An Experimental Investigation

    NASA Astrophysics Data System (ADS)

    Xiao, Xin; Shi, Yuanchun; Tang, Yun; Zhang, Nan

    During recent years, there has been a rapid growth in deployment of gossip-based protocol in many multicast applications. In a typical gossip-based protocol, each node acts as dual roles of receiver and sender, independently exchanging data with its neighbors to facilitate scalability and resilience. However, most of previous work in this literature seldom considered cheating issue of end users, which is also very important in face of the fact that the mutual cooperation inherently determines overall system performance. In this paper, we investigate the dishonest behaviors in decentralized gossip-based protocol through extensive experimental study. Our original contributions come in two-fold: In the first part of cheating study, we analytically discuss two typical cheating strategies, that is, intentionally increasing subscription requests and untruthfully calculating forwarding probability, and further evaluate their negative impacts. The results indicate that more attention should be paid to defending cheating behaviors in gossip-based protocol. In the second part of anti-cheating study, we propose a receiver-driven measurement mechanism, which evaluates individual forwarding traffic from the perspective of receivers and thus identifies cheating nodes with high incoming/outgoing ratio. Furthermore, we extend our mechanism by introducing reliable factor to further improve its accuracy. The experiments under various conditions show that it performs quite well in case of serious cheating and achieves considerable performance in other cases.

  8. Supervised versus unsupervised technology-based levodopa monitoring in Parkinson's disease: an intrasubject comparison.

    PubMed

    Lopane, Giovanna; Mellone, Sabato; Corzani, Mattia; Chiari, Lorenzo; Cortelli, Pietro; Calandra-Buonaura, Giovanna; Contin, Manuela

    2018-06-01

    We aimed to assess the intrasubject reproducibility of a technology-based levodopa (LD) therapeutic monitoring protocol administered in supervised versus unsupervised conditions in patients with Parkinson's disease (PD). The study design was pilot, intrasubject, single center, open and prospective. Twenty patients were recruited. Patients performed a standardized monitoring protocol instrumented by an ad hoc embedded platform after their usual first morning LD dose in two different randomized ambulatory sessions: one under a physician's supervision, the other self-administered. The protocol is made up of serial motor and non-motor tests, including alternate finger tapping, Timed Up and Go test, and measurement of blood pressure. Primary motor outcomes included comparisons of intrasubject LD subacute motor response patterns over the 3-h test in the two experimental conditions. Secondary outcomes were the number of intrasession serial test repetitions due to technical or handling errors and patients' satisfaction with the unsupervised LD monitoring protocol. Intrasubject LD motor response patterns were concordant between the two study sessions in all patients but one. Platform handling problems averaged 4% of total planned serial tests for both sessions. Ninety-five percent of patients were satisfied with the self-administered LD monitoring protocol. To our knowledge, this study is the first to explore the potential of unsupervised technology-based objective motor and non-motor tasks to monitor subacute LD dosing effects in PD patients. The results are promising for future telemedicine applications.

  9. 256 Slice Multi-detector Computed Tomography Thoracic Aorta Computed Tomography Angiography: Improved Luminal Opacification Using a Patient-Specific Contrast Protocol and Caudocranial Scan Acquisition.

    PubMed

    Saade, Charbel; El-Merhi, Fadi; El-Achkar, Bassam; Kerek, Racha; Vogl, Thomas J; Maroun, Gilbert Georges; Jamjoom, Lamia; Al-Mohiy, Hussain; Naffaa, Lena

    Caudocranial scan direction and contrast injection timing based on measured patient vessel dynamics can significantly improve arterial and aneurysmal opacification and reduce both contrast and radiation dose in the assessment of thoracic aortic aneurysms (TAA) using helical thoracic computed tomography angiography (CTA). To investigate opacification of the thoracic aorta and TAA using a caudocranial scan direction and a patient-specific contrast protocol. Thoracic aortic CTA was performed in 160 consecutive patients with suspected TAA using a 256-slice computed tomography scanner and a dual barrel contrast injector. Patients were subjected in equal numbers to one of two contrast protocols. Patient age and sex were equally distributed across both groups. Protocol A, the department's standard protocol, consisted of a craniocaudal scan direction with 100 mL of contrast, intravenously injected at a flow rate of 4.5 mL/s. Protocol B involved a caudocranial scan direction and a novel contrast formula based on patient cardiovascular dynamics, followed by 100 mL of saline at 4.5 mL/s. Each scan acquisition comprised of 120 kVp, 200 mA with modulation, temporal resolution 0.27 seconds, and pitch 0.889:1. The dose length product was measured between each protocol and data generated were compared using Mann-Whitney U nonparametric statistics. Receiver operating characteristic analysis, visual grading characteristic (VGC), and κ analyses were performed. Mean opacification in the thoracic aorta and aneurysm measured was 24 % and 55%, respectively. The mean contrast volume was significantly lower in protocol B (73 ± 10 mL) compared with A (100 ± 1 mL) (P<0.001). The contrast-to-noise ratio demonstrated significant differences between the protocols (protocol A, 18.2 ± 12.9; protocol B, 29.7 ± 0.61; P < 0.003). Mean effective dose in protocol B (2.6 ± 0.4 mSv) was reduced by 19% compared with A (3.2 ± 0.8 mSv) (P < 0.004). Aneurysmal detectability demonstrated significant increases by receiver operating characteristic and visual grading characteristic analysis for protocol B compared with A (P < 0.02), and reader agreement increased from poor to excellent. Significant increase in the visualization of TAAs following a caudocranial scan direction during helical thoracic CTA can be achieved using low-contrast volume based on patient-specific contrast formula.

  10. Absolute counting of neutrophils in whole blood using flow cytometry.

    PubMed

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens. © 2014 International Society for Advancement of Cytometry.

  11. Methods of analysis speech rate: a pilot study.

    PubMed

    Costa, Luanna Maria Oliveira; Martins-Reis, Vanessa de Oliveira; Celeste, Letícia Côrrea

    2016-01-01

    To describe the performance of fluent adults in different measures of speech rate. The study included 24 fluent adults, of both genders, speakers of Brazilian Portuguese, who were born and still living in the metropolitan region of Belo Horizonte, state of Minas Gerais, aged between 18 and 59 years. Participants were grouped by age: G1 (18-29 years), G2 (30-39 years), G3 (40-49 years), and G4 (50-59 years). The speech samples were obtained following the methodology of the Speech Fluency Assessment Protocol. In addition to the measures of speech rate proposed by the protocol (speech rate in words and syllables per minute), the rate of speech into phonemes per second and the articulation rate with and without the disfluencies were calculated. We used the nonparametric Friedman test and the Wilcoxon test for multiple comparisons. Groups were compared using the nonparametric Kruskal Wallis. The significance level was of 5%. There were significant differences between measures of speech rate involving syllables. The multiple comparisons showed that all the three measures were different. There was no effect of age for the studied measures. These findings corroborate previous studies. The inclusion of temporal acoustic measures such as speech rate in phonemes per second and articulation rates with and without disfluencies can be a complementary approach in the evaluation of speech rate.

  12. Oocyte-triggering day progesterone levels and endometrial appearance in normoresponders undergoing IVF/ICSI cycles: a hypothesis and a study protocol.

    PubMed

    Siristatidis, Charalampos; Drakopoulos, Panagiotis; Vogiatzi, Paraskevi; Karageorgiou, Vasilios; Daskalakis, George

    2018-05-16

    In this report, we propose a study protocol capable of improving IVF outcomes in subfertile women with expected normal ovarian response. This proposal derives from conflicting published data and observations in our daily practice, concerning the negative impact of progesterone (P4) elevation at the day of oocyte triggering on pregnancy outcomes. Our hypothesis points to the combination of two previous "suspects" of reduced success after assisted reproduction techniques (ART) - the endometrium ultrasonographic parameters and P4 elevation at the day of oocyte triggering on their impact on pregnancy outcomes. Up-to-the minute data show that, there is a different impact of elevated P4 in fresh, frozen and donor cycles, whereas there are plenty of reports pointing to a different endometrial gene expression on different P4 measurements. Gaps in the literature are linked with a variation of the measurements of P4, its cycle-to-cycle reproducibility, the different cut-off levels used, the impact of various protocols of ovarian stimulation and the limitations of systematic reviews originating from the initial studies. Our hypothesis states that the combination of P4 values and endometrial ultrasound parameters at the day of oocyte triggering can affect clinical pregnancy rates in normal responders undergoing ART.

  13. A neurocognitive approach for recovering upper extremity movement following subacute stroke: a randomized controlled pilot study

    PubMed Central

    Sallés, Laia; Martín-Casas, Patricia; Gironès, Xavier; Durà, María José; Lafuente, José Vicente; Perfetti, Carlo

    2017-01-01

    [Purpose] This study aims to describe a protocol based on neurocognitive therapeutic exercises and determine its feasibility and usefulness for upper extremity functionality when compared with a conventional protocol. [Subjects and Methods] Eight subacute stroke patients were randomly assigned to a conventional (control group) or neurocognitive (experimental group) treatment protocol. Both lasted 30 minutes, 3 times a week for 10 weeks and assessments were blinded. Outcome measures included: Motor Evaluation Scale for Upper Extremity in Stroke Patients, Motricity Index, Revised Nottingham Sensory Assessment and Kinesthetic and Visual Imagery Questionnaire. Descriptive measures and nonparametric statistical tests were used for analysis. [Results] The results indicate a more favorable clinical progression in the neurocognitive group regarding upper extremity functional capacity with achievement of the minimal detectable change. The functionality results are related with improvements on muscle strength and sensory discrimination (tactile and kinesthetic). [Conclusion] Despite not showing significant group differences between pre and post-treatment, the neurocognitive approach could be a safe and useful strategy for recovering upper extremity movement following stroke, especially regarding affected hands, with better and longer lasting results. Although this work shows this protocol’s feasibility with the panel of scales proposed, larger studies are required to demonstrate its effectiveness. PMID:28533607

  14. Assessment of the radioanatomic positioning of the osteoarthritic knee in serial radiographs: comparison of three acquisition techniques.

    PubMed

    Le Graverand, M-P H; Mazzuca, S; Lassere, M; Guermazi, A; Pickering, E; Brandt, K; Peterfy, C; Cline, G; Nevitt, M; Woodworth, T; Conaghan, P; Vignon, E

    2006-01-01

    Recent studies using various standardized radiographic acquisition techniques have demonstrated the necessity of reproducible radioanatomic alignment of the knee to assure precise measurements of medial tibiofemoral joint space width (JSW). The objective of the present study was to characterize the longitudinal performance of several acquisition techniques with respect to long-term reproducibility of positioning of the knee, and the impact of changes in positioning on the rate and variability of joint space narrowing (JSN). Eighty subjects were randomly selected from each of three cohorts followed in recent studies of the radiographic progression of knee osteoarthritis (OA): the Health ABC study (paired fixed-flexion [FF] radiographs taken at a 36-month interval); the Glucosamine Arthritis Intervention Trial (GAIT) (paired metatarsophalangeal [MTP] radiographs obtained at a 12-month interval), and a randomized clinical trial of doxycycline (fluoroscopically assisted semiflexed anteroposterior (AP) radiographs taken at a 16-month interval). Manual measurements were obtained from each radiograph to represent markers of radioanatomic positioning of the knee (alignment of the medial tibial plateau and X-ray beam, knee rotation, femorotibial angle) and to evaluate minimum JSW (mJSW) in the medial tibiofemoral compartment. The effects on the mean annualized rate of JSN and on the variability of that rate of highly reproduced vs variable positioning of the knee in serial radiographs were evaluated. Parallel or near-parallel alignment was achieved significantly more frequently with the fluoroscopically guided positioning used in the semiflexed AP protocol than with either the non-fluoroscopic FF or MTP protocol (68% vs 14% for both FF and MTP protocols when measured at the midpoint of the medial compartment; 75% vs 26% and 34% for the FF and MTP protocols, respectively, when measured at the site of mJSW; P<0.001 for each). Knee rotation was reproduced more frequently in semiflexed AP radiographs than in FF radiographs (66% vs 45%, P<0.01). In contrast, the FF technique yielded a greater proportion of paired radiographs in which the femorotibial angle was accurately reproduced than the semiflexed AP or MTP protocol (78% vs 59% and 56%, respectively, P<0.01 for each). Notably, only paired radiographs with parallel or near-parallel alignment exhibited a mean rate of JSN (+/-SD) in the OA knee that was more rapid and less variable than that measured in all knees (0.186+/-0.274 mm/year, standardized response to mean [SRM]=0.68 vs 0.128+/-0.291 mm/year, SRM=0.44). This study confirms the importance of parallel radioanatomic alignment of the anterior and posterior margins of the medial tibial plateau in detecting JSN in subjects with knee OA. The use of radiographic methods that assure parallel alignment during serial X-ray examinations will permit the design of more efficient studies of biomarkers of OA progression and of structure modification in knee OA.

  15. Measurement of Survival Time in Brachionus Rotifers: Synchronization of Maternal Conditions.

    PubMed

    Kaneko, Gen; Yoshinaga, Tatsuki; Gribble, Kristin E; Welch, David M; Ushio, Hideki

    2016-07-22

    Rotifers are microscopic cosmopolitan zooplankton used as models in ecotoxicological and aging studies due to their several advantages such as short lifespan, ease of culture, and parthenogenesis that enables clonal culture. However, caution is required when measuring their survival time as it is affected by maternal age and maternal feeding conditions. Here we provide a protocol for powerful and reproducible measurement of the survival time in Brachionus rotifers following a careful synchronization of culture conditions over several generations. Empirically, poor synchronization results in early mortality and a gradual decrease in survival rate, thus resulting in weak statistical power. Indeed, under such conditions, calorie restriction (CR) failed to significantly extend the lifespan of B. plicatilis although CR-induced longevity has been demonstrated with well-synchronized rotifer samples in past and present studies. This protocol is probably useful for other invertebrate models, including the fruitfly Drosophila melanogaster and the nematode Caenorhabditis elegans, because maternal age effects have also been reported in these species.

  16. Measurement of Survival Time in Brachionus Rotifers: Synchronization of Maternal Conditions

    PubMed Central

    Kaneko, Gen; Yoshinaga, Tatsuki; Gribble, Kristin E.; Welch, David M.; Ushio, Hideki

    2016-01-01

    Rotifers are microscopic cosmopolitan zooplankton used as models in ecotoxicological and aging studies due to their several advantages such as short lifespan, ease of culture, and parthenogenesis that enables clonal culture. However, caution is required when measuring their survival time as it is affected by maternal age and maternal feeding conditions. Here we provide a protocol for powerful and reproducible measurement of the survival time in Brachionus rotifers following a careful synchronization of culture conditions over several generations. Empirically, poor synchronization results in early mortality and a gradual decrease in survival rate, thus resulting in weak statistical power. Indeed, under such conditions, calorie restriction (CR) failed to significantly extend the lifespan of B. plicatilis although CR-induced longevity has been demonstrated with well-synchronized rotifer samples in past and present studies. This protocol is probably useful for other invertebrate models, including the fruitfly Drosophila melanogaster and the nematode Caenorhabditis elegans, because maternal age effects have also been reported in these species. PMID:27500471

  17. Multibreath alveolar oxygen tension imaging.

    PubMed

    Clapp, Justin; Hamedani, Hooman; Kadlecek, Stephen; Xin, Yi; Shaghaghi, Hoora; Siddiqui, Sarmad; Rossman, Milton D; Rizi, Rahim R

    2016-10-01

    This study tested the ability of a multibreath hyperpolarized HP (3) He MRI protocol to increase the accuracy of regional alveolar oxygen tension (PA O2 ) measurements by lessening the influence of gas-flow artifacts. Conventional single-breath PA O2 measurement has been susceptible to error induced by intervoxel gas flow, particularly when used to study subjects with moderate-to-severe chronic obstructive pulmonary disease (COPD). Both single-breath and multibreath PA O2 imaging schemes were implemented in seven human subjects (one healthy, three asymptomatic smokers, and three COPD). The number and location of voxels with nonphysiologic PA O2 values generated by intervoxel gas flow were compared between the two protocols. The multibreath scheme resulted in a significantly lower total percentage of nonphysiologic PA O2 values (6.0%) than the single-breath scheme (13.7%) (P = 0.006). PA O2 maps showed several patterns of gas-flow artifacts that were present in the single-breath protocol but mitigated by the multibreath approach. Multibreath imaging also allowed for the analysis of slow-filling areas that presented no signal after a single breath. A multibreath approach enhances the accuracy and completeness of noninvasive PA O2 measurement by significantly lessening the proportion of nonphysiologic values generated by intervoxel gas flow. Magn Reson Med 76:1092-1101, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  18. The response of salmon populations to geomorphic measurements at three scales

    Treesearch

    M.D. Bryant; R.D. Woodsmith

    2009-01-01

    Protocols to assess stream channel response to disturbances often focus on physical aspects ofthe stream at the reach scale without measurements of fish populations. In this study, estimates of juvenile salmon abundance in 511 habitat units within 25 reaches of 12 streams were made over 4 years and juxtaposed with...

  19. Blood Flow After Exercise-Induced Muscle Damage

    PubMed Central

    Selkow, Noelle M.; Herman, Daniel C.; Liu, Zhenqi; Hertel, Jay; Hart, Joseph M.; Saliba, Susan A.

    2015-01-01

    Context: The most common modality used to address acute inflammation is cryotherapy. Whereas pain decreases with cryotherapy, evidence that changes occur in perfusion of skeletal muscle is limited. We do not know whether ice attenuates the increases in perfusion associated with acute inflammation. Objective: To examine the effects of repeated applications of ice bags on perfusion of the gastrocnemius muscle after an eccentric exercise protocol. Design: Controlled laboratory study. Setting: Laboratory. Patients or Other Participants: Eighteen healthy participants (3 men, 15 women; age = 22.2 ± 2.2 years, height = 166.0 ± 11.9 cm, mass = 69.4 ± 25.0 kg). Intervention(s): To induce eccentric muscle damage, participants performed 100 unilateral heel-lowering exercises off a step to the beat of a metronome. A randomized intervention (cryotherapy, sham, control) was applied to the exercised lower extremity immediately after the protocol and again at 10, 24, and 34 hours after the protocol. Main Outcome Measure(s): Baseline perfusion measurements (blood volume, blood flow, and blood flow velocity) were taken using contrast-enhanced ultrasound of the exercised leg. Perfusion was reassessed after the first intervention and 48 hours after the protocol as percentage change scores. Pain was measured with a visual analog scale at baseline and at 10, 24, 34, and 48 hours after the protocol. Separate repeated-measures analyses of variance were used to assess each dependent variable. Results: We found no interactions among interventions for microvascular perfusion. Blood volume and blood flow, however, increased in all conditions at 48 hours after exercise (P < .001), and blood flow velocity decreased postintervention from baseline (P = .041). We found a time-by-intervention interaction for pain (P = .009). Visual analog scale scores were lower for the cryotherapy group than for the control group at 34 and 48 hours after exercise. Conclusions: Whereas eccentric muscle damage resulted in increased blood flow, ice did not decrease muscle perfusion 48 hours after exercise. Therefore, ice does not seem to decrease muscle perfusion when blood flow is elevated, as it would be during inflammation. PMID:25658816

  20. Use and efficacy of a nutrition protocol for patients with burns in intensive care.

    PubMed

    Lown, D

    1991-01-01

    The University of Michigan Burn Center uses a protocol to standardize the assessment, initiation, and monitoring of nutritional support for patients with burns of greater than 30% total body surface area (TBSA). Six patients with 20% to 80% TBSA burns were followed for 3 weeks to determine the effect of the protocol on the assessment, initiation, monitoring, and adequacy of nutritional support. The protocol calls for resting energy expenditure (REE) measurement within 24 hours of injury, to be repeated 3 times per week, for assessment of caloric requirements. Patients experienced an average delay before first REE measurement of 3 days after burn injury because measurements were unavailable on weekends and surgical days. REE measurements were used to determine caloric requirements and to tailor nutritional support to fluctuating metabolic needs. In four of the six patients a Dobhoff feeding tube (Biosearch Medical Products, Inc., Somerville, N.J.) was placed in the small bowel and enteral nutrition was initiated within 24 hours of admission, as outlined in the protocol. Two patients received concurrent parenteral nutrition because of difficulty in placing the Dobhoff feeding tube when fluoroscopy was not available. The three patients receiving nutrition solely through enteral feeding had achieved 100% of their caloric requirements by day 2, 4, and greater than 7 days after injury, respectively. Overall, the six patients received enterally an average of 75% of their caloric requirements. The major reason for inadequate enteral support was interruption of tube feedings because of tube dislodgment or multiple surgical procedures. The protocol used weekly measurements of total iron-binding capacity and prealbumin level s parameters of nutritional support.(ABSTRACT TRUNCATED AT 250 WORDS)

Top