Sample records for measures sensitivity specificity

  1. Methods for assessing patient-clinician communication about depression in primary care: what you see depends on how you look.

    PubMed

    Henry, Stephen G; Feng, Bo; Franks, Peter; Bell, Robert A; Tancredi, Daniel J; Gottfeld, Dustin; Kravitz, Richard L

    2014-10-01

    To advance research on depression communication and treatment by comparing assessments of communication about depression from patient report, clinician report, and chart review to assessments from transcripts. One hundred sixty-four primary care visits from seven health care systems (2010-2011). Presence or absence of discussion about depressive symptoms, treatment recommendations, and follow-up was measured using patient and clinician postvisit questionnaires, chart review, and coding of audio transcripts. Sensitivity and specificity of indirect measures compared to transcripts were calculated. Patient report was sensitive for mood (83 percent) and sleep (83 percent) but not suicide (55 percent). Patient report was specific for suicide (86 percent) but not for other symptoms (44-75 percent). Clinician report was sensitive for all symptoms (83-98 percent) and specific for sleep, memory, and suicide (80-87 percent), but not for other symptoms (45-48 percent). Chart review was not sensitive for symptoms (50-73 percent), but it was specific for sleep, memory, and suicide (88-96 percent). All indirect measures had low sensitivity for treatment recommendations (patient report: 24-42 percent, clinician report 38-50 percent, chart review 49-67 percent) but high specificity (89-96 percent). For definite follow-up plans, all three indirect measures were sensitive (82-96 percent) but not specific (40-57 percent). Clinician report and chart review generally had the most favorable sensitivity and specificity for measuring discussion of depressive symptoms and treatment recommendations, respectively. © Health Research and Educational Trust.

  2. Diagnostic Accuracy of Memory Measures in Alzheimer’s Dementia and Mild Cognitive Impairment: a Systematic Review and Meta-Analysis

    PubMed Central

    Weissberger, Gali H.; Strong, Jessica V.; Stefanidis, Kayla B.; Summers, Mathew J.; Bondi, Mark W.; Stricker, Nikki H.

    2018-01-01

    With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer’s dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer’s disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers. PMID:28940127

  3. Diagnostic Accuracy of Memory Measures in Alzheimer's Dementia and Mild Cognitive Impairment: a Systematic Review and Meta-Analysis.

    PubMed

    Weissberger, Gali H; Strong, Jessica V; Stefanidis, Kayla B; Summers, Mathew J; Bondi, Mark W; Stricker, Nikki H

    2017-12-01

    With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer's dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer's disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers.

  4. The psychometric properties, sensitivity and specificity of the geriatric anxiety inventory, hospital anxiety and depression scale, and rating anxiety in dementia scale in aged care residents.

    PubMed

    Creighton, Alexandra S; Davison, Tanya E; Kissane, David W

    2018-02-22

    Limited research has been conducted into the identification of a valid and reliable screening measure for anxiety in aged care settings, despite it being one of the most common psychological conditions. This study aimed to determine an appropriate anxiety screening tool for aged care by comparing the reliability and validity of three commonly used measures and identifying specific cut-offs for the identification of generalized anxiety disorder (GAD). One-hundred and eighty nursing home residents (M age = 85.39 years) completed the GAI, HADS-A, and RAID, along with a structured diagnostic interview. Twenty participants (11.1%) met DSM-5 criteria for GAD. All measures had good psychometric properties , although reliability estimates for the HADS-A were sub-optimal. Privileging sensitivity , the GAI cut-off score of 9 gave sensitivity of 90.0% and specificity of 86.3%; HADS-A cut-off of 6 gave sensitivity of 90.0% and specificity of 80.6%; and RAID cut-off of 11 gave sensitivity of 85.0% and specificity of 72.5%. While all three measures had adequate reliability, validity, and cut-scores with high levels of sensitivity and specificity to detect anxiety within aged care, the GAI was the most consistently reliable and valid measure for screening for GAD.

  5. Power Calculations to Select Instruments for Clinical Trial Secondary Endpoints. A Case Study of Instrument Selection for Post-Traumatic Stress Symptoms in Subjects with Acute Respiratory Distress Syndrome

    PubMed Central

    Schoenfeld, David A.; Brown, Samuel M.; Hough, Catherine L.; Yealy, Donald M.; Moss, Marc; Angus, Derek C.; Iwashyna, Theodore J.

    2017-01-01

    Rationale: After the sample size of a randomized clinical trial (RCT) is set by the power requirement of its primary endpoint, investigators select secondary endpoints while unable to further adjust sample size. How the sensitivity and specificity of an instrument used to measure these outcomes, together with their expected underlying event rates, affect an RCT’s power to measure significant differences in these outcomes is poorly understood. Objectives: Motivated by the design of an RCT of neuromuscular blockade in acute respiratory distress syndrome, we examined how power to detect a difference in secondary endpoints varies with the sensitivity and specificity of the instrument used to measure such outcomes. Methods: We derived a general formula and Stata code for calculating an RCT’s power to detect differences in binary outcomes when such outcomes are measured with imperfect sensitivity and specificity. The formula informed the choice of instrument for measuring post-traumatic stress–like symptoms in the Reevaluation of Systemic Early Neuromuscular Blockade RCT (www.clinicaltrials.gov identifier NCT02509078). Measurements and Main Results: On the basis of published sensitivities and specificities, the Impact of Events Scale-Revised was predicted to measure a 36% symptom rate, whereas the Post-Traumatic Stress Symptoms instrument was predicted to measure a 23% rate, if the true underlying rate of post-traumatic stress symptoms were 25%. Despite its lower sensitivity, the briefer Post-Traumatic Stress Symptoms instrument provided superior power to detect a difference in rates between trial arms, owing to its higher specificity. Conclusions: Examining instruments’ power to detect differences in outcomes may guide their selection when multiple instruments exist, each with different sensitivities and specificities. PMID:27788018

  6. Power Calculations to Select Instruments for Clinical Trial Secondary Endpoints. A Case Study of Instrument Selection for Post-Traumatic Stress Symptoms in Subjects with Acute Respiratory Distress Syndrome.

    PubMed

    Sjoding, Michael W; Schoenfeld, David A; Brown, Samuel M; Hough, Catherine L; Yealy, Donald M; Moss, Marc; Angus, Derek C; Iwashyna, Theodore J

    2017-01-01

    After the sample size of a randomized clinical trial (RCT) is set by the power requirement of its primary endpoint, investigators select secondary endpoints while unable to further adjust sample size. How the sensitivity and specificity of an instrument used to measure these outcomes, together with their expected underlying event rates, affect an RCT's power to measure significant differences in these outcomes is poorly understood. Motivated by the design of an RCT of neuromuscular blockade in acute respiratory distress syndrome, we examined how power to detect a difference in secondary endpoints varies with the sensitivity and specificity of the instrument used to measure such outcomes. We derived a general formula and Stata code for calculating an RCT's power to detect differences in binary outcomes when such outcomes are measured with imperfect sensitivity and specificity. The formula informed the choice of instrument for measuring post-traumatic stress-like symptoms in the Reevaluation of Systemic Early Neuromuscular Blockade RCT ( www.clinicaltrials.gov identifier NCT02509078). On the basis of published sensitivities and specificities, the Impact of Events Scale-Revised was predicted to measure a 36% symptom rate, whereas the Post-Traumatic Stress Symptoms instrument was predicted to measure a 23% rate, if the true underlying rate of post-traumatic stress symptoms were 25%. Despite its lower sensitivity, the briefer Post-Traumatic Stress Symptoms instrument provided superior power to detect a difference in rates between trial arms, owing to its higher specificity. Examining instruments' power to detect differences in outcomes may guide their selection when multiple instruments exist, each with different sensitivities and specificities.

  7. Diagnostic accuracy of fundal height and handheld ultrasound-measured abdominal circumference to screen for fetal growth abnormalities

    PubMed Central

    Haragan, Adriane F.; Hulsey, Thomas C.; Hawk, Angela F.; Newman, Roger B.; Chang, Eugene Y.

    2015-01-01

    OBJECTIVE We sought to compare fundal height and handheld ultrasound–measured fetal abdominal circumference (HHAC) for the prediction of fetal growth restriction (FGR) or large for gestational age. STUDY DESIGN This was a diagnostic accuracy study in nonanomalous singleton pregnancies between 24 and 40 weeks’ gestation. Patients underwent HHAC and fundal height measurement prior to formal growth ultrasound. FGR was defined as estimated fetal weight less than 10%, whereas large for gestational age was defined as estimated fetal weight greater than 90%. Sensitivity and specificity were calculated and compared using methods described elsewhere. RESULTS There were 251 patients included in this study. HHAC had superior sensitivity and specificity for the detection of FGR (sensitivity, 100% vs 42.86%) and (specificity, 92.62% vs 85.24%). HHAC had higher specificity but lower sensitivity when screening for LGA (specificity, 85.66% vs 66.39%) and (sensitivity, 57.14% vs 71.43%). CONCLUSION HHAC could prove to be a valuable screening tool in the detection of FGR. Further studies are needed in a larger population. PMID:25818672

  8. Impact of test sensitivity and specificity on pig producer incentives to control Mycobacterium avium infections in finishing pigs.

    PubMed

    van Wagenberg, Coen P A; Backus, Gé B C; Wisselink, Henk J; van der Vorst, Jack G A J; Urlings, Bert A P

    2013-09-01

    In this paper we analyze the impact of the sensitivity and specificity of a Mycobacterium avium (Ma) test on pig producer incentives to control Ma in finishing pigs. A possible Ma control system which includes a serodiagnostic test and a penalty on finishing pigs in herds detected with Ma infection was modelled. Using a dynamic optimization model and a grid search of deliveries of herds from pig producers to slaughterhouse, optimal control measures for pig producers and optimal penalty values for deliveries with increased Ma risk were identified for different sensitivity and specificity values. Results showed that higher sensitivity and lower specificity induced use of more intense control measures and resulted in higher pig producer costs and lower Ma seroprevalence. The minimal penalty value needed to comply with a threshold for Ma seroprevalence in finishing pigs at slaughter was lower at higher sensitivity and lower specificity. With imperfect specificity a larger sample size decreased pig producer incentives to control Ma seroprevalence, because the higher number of false positives resulted in an increased probability of rejecting a batch of finishing pigs irrespective of whether the pig producer applied control measures. We conclude that test sensitivity and specificity must be considered in incentive system design to induce pig producers to control Ma in finishing pigs with minimum negative effects. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Sensitivity and Specificity of French Language and Processing Measures for the Identification of Primary Language Impairment at Age 5

    ERIC Educational Resources Information Center

    Thordardottir, Elin; Kehayia, Eva; Mazer, Barbara; Lessard, Nicole; Majnemer, Annette; Sutton, Ann; Trudeau, Natacha; Chilingaryan, Gevorg

    2011-01-01

    Purpose: Research on the diagnostic accuracy of different language measures has focused primarily on English. This study examined the sensitivity and specificity of a range of measures of language knowledge and language processing for the identification of primary language impairment (PLI) in French-speaking children. Because of the lack of…

  10. Validation of time to task performance assessment method in simulation: A comparative design study.

    PubMed

    Shinnick, Mary Ann; Woo, Mary A

    2018-05-01

    There is a lack of objective and valid measures for assessing nursing clinical competence which could adversely impact patient safety. Therefore, we evaluated an objective assessment of clinical competence, Time to Task (ability to perform specific, critical nursing care activities within 5 min), and compared it to two subjective measures, (Lasater Clinical Judgement Rubric [LCJR] and common "pass/fail" assessment). Using a prospective, "Known Groups" (Expert vs. Novice nurses) comparative design, Expert nurses (ICU nurses with >5 years of ICU experience) and Novice nurses (senior prelicensure nursing students) participated individually in a simulation of a patient in decompensated heart failure. Fourteen nursing instructors or preceptors, blinded to group assignment, reviewed 28 simulation videos (15 Expert and 13 Novice) and scored them using the LCJR and pass/fail assessments. Time to Task assessment was scored based on time thresholds for specific nursing actions prospectively set by an expert clinical panel. Statistical analysis consisted of Medians Test and sensitivity and specificity analyses. The LCJR total score was significantly different between Experts and Novices (p < 0.01) and revealed adequate sensitivity (ability to correctly identify "Expert" nurses; 0.72) but had a low specificity (ability to correctly identify "Novice" nurses; 0.40). For the subjective measure 'pass/fail', sensitivity was high (0.90) but specificity was low (0.47). The Time to Task measure had statistical significance between Expert and Novice groups (p < 0.01) and sensitivity (0.80) and specificity (0.85) were good. Commonly used subjective measures of clinical nursing competence have difficulties with achieving acceptable specificity. However, an objective measure, Time to Task, had good sensitivity and specificity in differentiating between groups. While more than one assessment instrument should be used to determine nurse competency, an objective measure, such as Time to Task, warrants further study. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. The sensitivity and specificity of clinical measures of sport concussion: three tests are better than one

    PubMed Central

    Resch, Jacob E; Brown, Cathleen N; Schmidt, Julianne; Macciocchi, Stephen N; Blueitt, Damond; Cullum, C Munro; Ferrara, Michael S

    2016-01-01

    Context A battery of clinical measures of neurocognition, balance and symptoms has been recommended for the management of sport concussion (SC) but is based on variable evidence. Objective To examine the sensitivity and specificity of a battery of tests to assess SC in college athletes. Design Cross-sectional. Setting Research laboratory. Patients or other participants Division 1 athletes diagnosed with a SC (n=40) who were 20.2±1.60 years of age and 180.5±11.12 cm tall and healthy athletes (n=40) who were 19.0±0.93 years of age and 179.1±11.39 cm tall were enrolled. Intervention(s) Participants were administered Immediate Postconcussion Assessment and Cognitive Test (ImPACT), the Sensory Organization Test (SOT) and the Revised Head Injury Scale (HIS-r) prior to and up to 24 h following injury between the 2004 and 2014 sport seasons. Sensitivity and specificity were calculated using predictive discriminant analyses (PDA) and clinical interpretation guidelines. Main outcome measures Outcome measures included baseline and postinjury ImPACT, SOT and HIS-r composite scores. Results Using PDA, each clinical measure's sensitivity ranged from 55.0% to 77.5% and specificity ranged from 52.5% to 100%. The test battery possessed a sensitivity and specificity of 80.0% and 100%, respectively. Using clinical interpretation guidelines, sensitivity ranged from 55% to 97.5% individually, and 100% when combined. Conclusions Our results support a multidimensional approach to assess SC in college athletes which correctly identified 80–100% of concussed participants as injured. When each test was evaluated separately, up to 47.5% of our sample was misclassified. Caution is warranted when using singular measures to manage SC. PMID:27900145

  12. Application of Normative Occipital Condyle-C1 Interval Measurements to Detect Atlanto-Occipital Injury in Children.

    PubMed

    Corcoran, B; Linscott, L L; Leach, J L; Vadivelu, S

    2016-05-01

    Prior studies have found that widening or asymmetry of the occipital condyle-C1 interval on CT is a sensitive and specific marker for atlanto-occipital dislocation. Previously reported abnormal occipital condyle-C1 interval values are not age-specific, possibly leading to false-positive findings in younger children, in whom this joint space is normally larger than that in adults. This study assesses the utility of applying age-specific normative occipital condyle-C1 interval ranges to documented cases of atlanto-occipital injury compared with previously reported abnormal cutoff values. Retrospective review of CT and MR imaging of 14 subjects with atlanto-occipital injury was performed, and occipital condyle-C1 interval measurements were made for each subject. Sensitivities and specificities of proposed occipital condyle-C1 interval cutoffs of 2 and 3 SDs above the mean and previously published occipital condyle-C1 interval cutoffs for atlanto-occipital injury were then calculated on the basis of occipital condyle-C1 interval measurements for each subject. An occipital condyle-C1 interval 2 SDs above the age-specific mean has a sensitivity of 50% and specificity of 89%-100%, depending on the age group. An occipital condyle-C1 interval 3 SDs above the age-specific mean has a sensitivity of 50% and a specificity of 95%-100%. A 4.0-mm occipital condyle-C1 interval has a sensitivity of 36% and a specificity of 100% in all age groups. A 2.5-mm occipital condyle-C1 interval has a sensitivity of 93% and a specificity of 18%-100%. Occipital condyle-C1 interval widening cutoffs used to establish atlanto-occipital injury lack both sensitivity and specificity in children and young teenagers. MR imaging is necessary to establish a diagnosis of atlanto-occipital injury in children and young teenagers when the appropriate mechanism of injury is present. © 2016 by American Journal of Neuroradiology.

  13. Estimating sensitivity and specificity for technology assessment based on observer studies.

    PubMed

    Nishikawa, Robert M; Pesce, Lorenzo L

    2013-07-01

    The goal of this study was to determine the accuracy and precision of using scores from a receiver operating characteristic rating scale to estimate sensitivity and specificity. We used data collected in a previous study that measured the improvements in radiologists' ability to classify mammographic microcalcification clusters as benign or malignant with and without the use of a computer-aided diagnosis scheme. Sensitivity and specificity were estimated from the rating data from a question that directly asked the radiologists their biopsy recommendations, which was used as the "truth," because it is the actual recall decision, thus it is their subjective truth. By thresholding the rating data, sensitivity and specificity were estimated for different threshold values. Because of interreader and intrareader variability, estimated sensitivity and specificity values for individual readers could be as much as 100% in error when using rating data compared to using the biopsy recommendation data. When pooled together, the estimates using thresholding the rating data were in good agreement with sensitivity and specificity estimated from the recommendation data. However, the statistical power of the rating data estimates was lower. By simply asking the observer his or her explicit recommendation (eg, biopsy or no biopsy), sensitivity and specificity can be measured directly, giving a more accurate description of empirical variability and the power of the study can be maximized. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  14. Intolerance for discomfort among smokers: comparison of smoking-specific and non-specific measures to smoking history and patterns.

    PubMed

    Sirota, Alan D; Rohsenow, Damaris J; Dolan, Sara L; Martin, Rosemarie A; Kahler, Christopher W

    2013-03-01

    Intolerance of discomfort associated with recent smoking cessation has been studied with only one smoking-specific questionnaire. The present study investigates the extent to which the previously validated Intolerance for Smoking Abstinence Discomfort Questionnaire (IDQ-S) scales share variance with (a) laboratory measures of distress tolerance (Paced Serial Addition Task and a breath-holding task) that have themselves been validated against smoking history, (b) the cold pressor task (not previously validated for smoking), and (c) an anxiety sensitivity questionnaire previously used for a similar purpose. The study then tests the hypothesis that the IDQ-S scales will have a higher correlation with smoking rate and dependence and with number and length of past smoking cessation attempts than with anxiety sensitivity or behavioral distress tolerance tasks do, since those measures are not smoking-specific. Sixty daily smokers recruited from the community completed the measures. The behavioral tasks and anxiety sensitivity shared little common variance. Anxiety sensitivity correlated more highly with IDQ-S than did the behavioral tasks but only 27% of variance was shared with the IDQ-S Withdrawal Intolerance; no distress tolerance measure correlated significantly with the IDQ-S Lack of Cognitive Coping scale. Only the IDQ-S scales correlated significantly with nicotine dependence, rate and past cessation: Withdrawal Intolerance with nicotine dependence and rate, and Lack of Cognitive Coping with fewer quit attempts. The smoking-specific measure of intolerance for discomfort may be more useful in smoking research than the less specific measures of distress tolerance. Published by Elsevier Ltd.

  15. The sensitivity and specificity of clinical measures of sport concussion: three tests are better than one.

    PubMed

    Resch, Jacob E; Brown, Cathleen N; Schmidt, Julianne; Macciocchi, Stephen N; Blueitt, Damond; Cullum, C Munro; Ferrara, Michael S

    2016-01-01

    A battery of clinical measures of neurocognition, balance and symptoms has been recommended for the management of sport concussion (SC) but is based on variable evidence. To examine the sensitivity and specificity of a battery of tests to assess SC in college athletes. Cross-sectional. Research laboratory. Division 1 athletes diagnosed with a SC (n=40) who were 20.2±1.60 years of age and 180.5±11.12 cm tall and healthy athletes (n=40) who were 19.0±0.93 years of age and 179.1±11.39 cm tall were enrolled. Participants were administered Immediate Postconcussion Assessment and Cognitive Test (ImPACT), the Sensory Organization Test (SOT) and the Revised Head Injury Scale (HIS-r) prior to and up to 24 h following injury between the 2004 and 2014 sport seasons. Sensitivity and specificity were calculated using predictive discriminant analyses (PDA) and clinical interpretation guidelines. Outcome measures included baseline and postinjury ImPACT, SOT and HIS-r composite scores. Using PDA, each clinical measure's sensitivity ranged from 55.0% to 77.5% and specificity ranged from 52.5% to 100%. The test battery possessed a sensitivity and specificity of 80.0% and 100%, respectively. Using clinical interpretation guidelines, sensitivity ranged from 55% to 97.5% individually, and 100% when combined. Our results support a multidimensional approach to assess SC in college athletes which correctly identified 80-100% of concussed participants as injured. When each test was evaluated separately, up to 47.5% of our sample was misclassified. Caution is warranted when using singular measures to manage SC.

  16. Effect of Sport Related Concussion on Clinically Measured Simple Reaction Time

    PubMed Central

    Eckner, James T.; Kutcher, Jeffrey S.; Broglio, Steven P.; Richardson, James K.

    2013-01-01

    Background Reaction time (RT) is a valuable component of the sport concussion assessment battery. RT is typically measured using computers running specialized software, which limits its applicability in some athletic settings and populations. To address this, we developed a simple clinical test of RT (RTclin) that involves grasping a falling measuring stick. Purpose To determine the effect of concussion on RTclin and its sensitivity and specificity for concussion. Materials and methods Concussed athletes (n=28) and non-concussed control teammates (n=28) completed RTclin assessments at baseline and within 48 hours of injury. Repeated measures ANOVA compared mean baseline and follow-up RTclin values between groups. Sensitivity and specificity were calculated over a range of reliable change confidence levels. Results RTclin differed significantly between groups (p < .001): there was significant prolongation from baseline to post-injury in the concussed group (p= .003), with a trend toward improvement in the control group (p = .058). Sensitivity and specificity were maximized when a critical change value of 0 ms was applied (i.e., any increase in RTclin from baseline was interpreted as abnormal), which corresponded to a sensitivity of 75%, specificity of 68%, and a 65% reliable change confidence level. Conclusions RTclin appears sensitive to the effects of concussion and distinguished concussed and non-concussed athletes with similar sensitivity and specificity to other commonly used concussion assessment tools. Given its simplicity, low cost, and minimal time requirement, RTclin should be considered a viable component of the sports medicine provider’s multifaceted concussion assessment battery. PMID:23314889

  17. Relationship between the surrogate anthropometric measures, foot length and chest circumference and birth weight among newborns of Sarlahi, Nepal.

    PubMed

    Mullany, L C; Darmstadt, G L; Khatry, S K; Leclerq, S C; Tielsch, J M

    2007-01-01

    Classification of infants into low birth weight (LBW, <2500 g) or very low birth weight (VLBW, <2000 g) categories is a crucial step in targeting interventions to high-risk infants. To compare the validity of chest circumference and foot length as surrogate anthropometric measures for the identification of LBW and VLBW infants. Newborn infants (n=1640) born between March and June 2004 in 30 Village Development Committees of Sarlahi district, Nepal. Chest circumference, foot length and weight (SECA 727, precise to 2 g) of newborns were measured within 72 h after birth. The sensitivity, specificity and predictive values for a range of cutoff points of the anthropometric measures were estimated using the digital scale measurements as the gold standard. Among LBW infants (469/1640, 28.6%), chest circumference measures <30.3 cm were 91% sensitive and 83% specific. Similar levels of sensitivity for foot length were achieved only with considerable loss of specificity (<45%). Foot length measurements <6.9 cm were 88% sensitive and 86% specific for the identification of VLBW infants. Chest circumference was superior to foot length in classification of infants into birth weight categories. For the identification of VLBW infants, foot length performed well, and may be preferable to chest circumference, as the former measure does not require removal of infant swaddling clothes. In the absence of more precise direct measures of birth weight, chest circumference is recommended over foot length for the identification of LBW infants.

  18. Measurement of blood pressure for the diagnosis and management of hypertension in different ethnic groups: one size fits all.

    PubMed

    Gill, Paramjit; Haque, M Sayeed; Martin, Una; Mant, Jonathan; Mohammed, Mohammed A; Heer, Gurdip; Johal, Amanpreet; Kaur, Ramandeep; Schwartz, Claire; Wood, Sally; Greenfield, Sheila M; McManus, Richard J

    2017-02-08

    Hypertension is a major risk factor for cardiovascular disease and prevalence varies by ethnic group. The diagnosis and management of blood pressure are informed by guidelines largely based on data from white populations. This study addressed whether accuracy of blood pressure measurement in terms of diagnosis of hypertension varies by ethnicity by comparing two measurement modalities (clinic blood pressure and home monitoring) with a reference standard of ambulatory BP monitoring in three ethnic groups. Cross-sectional population study (June 2010 - December 2012) with patients (40-75 years) of white British, South Asian and African Caribbean background with and without a previous diagnosis of hypertension recruited from 28 primary care practices. The study compared the test performance of clinic BP (using various protocols) and home-monitoring (1 week) with a reference standard of mean daytime ambulatory measurements using a threshold of 140/90 mmHg for clinic and 135/85 mmHg for out of office measurement. A total of 551 participants had complete data of whom 246 were white British, 147 South Asian and 158 African Caribbean. No consistent difference in accuracy of methods of blood pressure measurement was observed between ethnic groups with or without a prior diagnosis of hypertension: for people without hypertension, clinic measurement using three different methodologies had high specificity (75-97%) but variable sensitivity (33-65%) whereas home monitoring had sensitivity of 68-88% and specificity of 64-80%. For people with hypertension, detection of a raised blood pressure using clinic measurements had sensitivities of 34-69% with specificity of 73-92% and home monitoring had sensitivity (81-88%) and specificity (55-65%). For people without hypertension, ABPM remains the choice for diagnosing hypertension compared to the other modes of BP measurement regardless of ethnicity. Differences in accuracy of home monitoring and clinic monitoring (higher sensitivity of the former; higher specificity of the latter) were also not affected by ethnicity.

  19. The exit interview as a proxy measure of malaria case management practice: sensitivity and specificity relative to direct observation.

    PubMed

    Pulford, Justin; Siba, Peter M; Mueller, Ivo; Hetzel, Manuel W

    2014-12-03

    This paper aims to assess the sensitivity and specificity of exit interviews as a measure of malaria case management practice as compared to direct observation. The malaria case management of 1654 febrile patients attending 110 health facilities from across Papua New Guinea was directly observed by a trained research officer as part of a repeat cross sectional survey. Patient recall of 5 forms of clinical advice and 5 forms of clinical action were then assessed at service exit and statistical analyses on matched observation/exit interview data conducted. The sensitivity of exit interviews with respect to clinical advice ranged from 36.2% to 96.4% and specificity from 53.5% to 98.6%. With respect to clinical actions, sensitivity of the exit interviews ranged from 83.9% to 98.3% and specificity from 70.6% to 98.1%. The exit interview appears to be a valid measure of objective malaria case management practices such as the completion of a diagnostic test or the provision of antimalarial medication, but may be a less valid measure of low frequency, subjective practices such as the provision of malaria prevention advice.

  20. Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV) processing speed scores as measures of noncredible responding: The third generation of embedded performance validity indicators.

    PubMed

    Erdodi, Laszlo A; Abeare, Christopher A; Lichtenstein, Jonathan D; Tyson, Bradley T; Kucharski, Brittany; Zuccato, Brandon G; Roth, Robert M

    2017-02-01

    Research suggests that select processing speed measures can also serve as embedded validity indicators (EVIs). The present study examined the diagnostic utility of Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV) subtests as EVIs in a mixed clinical sample of 205 patients medically referred for neuropsychological assessment (53.3% female, mean age = 45.1). Classification accuracy was calculated against 3 composite measures of performance validity as criterion variables. A PSI ≤79 produced a good combination of sensitivity (.23-.56) and specificity (.92-.98). A Coding scaled score ≤5 resulted in good specificity (.94-1.00), but low and variable sensitivity (.04-.28). A Symbol Search scaled score ≤6 achieved a good balance between sensitivity (.38-.64) and specificity (.88-.93). A Coding-Symbol Search scaled score difference ≥5 produced adequate specificity (.89-.91) but consistently low sensitivity (.08-.12). A 2-tailed cutoff on the Coding/Symbol Search raw score ratio (≤1.41 or ≥3.57) produced acceptable specificity (.87-.93), but low sensitivity (.15-.24). Failing ≥2 of these EVIs produced variable specificity (.81-.93) and sensitivity (.31-.59). Failing ≥3 of these EVIs stabilized specificity (.89-.94) at a small cost to sensitivity (.23-.53). Results suggest that processing speed based EVIs have the potential to provide a cost-effective and expedient method for evaluating the validity of cognitive data. Given their generally low and variable sensitivity, however, they should not be used in isolation to determine the credibility of a given response set. They also produced unacceptably high rates of false positive errors in patients with moderate-to-severe head injury. Combining evidence from multiple EVIs has the potential to improve overall classification accuracy. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  1. Administrative database code accuracy did not vary notably with changes in disease prevalence.

    PubMed

    van Walraven, Carl; English, Shane; Austin, Peter C

    2016-11-01

    Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Structural and functional assessment of macula to diagnose glaucoma.

    PubMed

    Rao, H L; Hussain, R S M; Januwada, M; Pillutla, L N; Begum, V U; Chaitanya, A; Senthil, S; Garudadri, C S

    2017-04-01

    PurposeTo compare the diagnostic abilities of structural (ganglion cell-inner plexiform layer (GCIPL) thickness measured using spectral domain optical coherence tomography (SDOCT)) and functional (visual sensitivities measured using standard automated perimetry (SAP) and microperimetry (MP)) assessments of macula in glaucoma.MethodsIn a prospective study, 46 control eyes (28 subjects) and 61 glaucoma eyes (46 patients) underwent visual sensitivity estimation at macula (central 10°) by SAP and MP, and GCIPL thickness measurement at macula by SDOCT. Glaucoma was diagnosed by experts based on the optic disc and retinal nerve fiber layer changes. Area under the receiver-operating characteristic (AUC) curves and sensitivities at 95% specificity were used to assess the diagnostic ability of visual sensitivity and GCIPL measurements at various macular sectors.ResultsAUCs of GCIPL parameters ranged between 0.58 and 0.79. AUCs of SAP and MP sensitivities ranged between 0.59 and 0.71, and 0.59 and 0.72, respectively. There were no statistically significant differences between the AUCs of corresponding sector measurements (P>0.10 for all comparisons). Sensitivities at 95% specificities ranged from 31-59% for GCIPL parameters, 16-34% for SAP, and 8-38% for MP parameters. Sensitivities were significantly better with GCIPL compared with SAP and MP parameters in diagnosing glaucoma. Inferotemporal, inferior, and superotemporal sector measurements of GCIPL and visual sensitivity showed the best abilities to diagnose glaucoma.ConclusionsComparing the diagnostic abilities of structural and functional tests at macula in glaucoma, GCIPL thickness measurements with SDOCT performed better than the visual sensitivity measurements by SAP and MP.

  3. Measurement of neutralizing serum antibodies of patients vaccinated with human papillomavirus L1 or L2-based immunogens using furin-cleaved HPV Pseudovirions.

    PubMed

    Wang, Joshua W; Jagu, Subhashini; Wang, Chenguang; Kitchener, Henry C; Daayana, Sai; Stern, Peter L; Pang, Susana; Day, Patricia M; Huh, Warner K; Roden, Richard B S

    2014-01-01

    Antibodies specific for neutralizing epitopes in either Human papillomavirus (HPV) capsid protein L1 or L2 can mediate protection from viral challenge and thus their accurate and sensitive measurement at high throughput is likely informative for monitoring response to prophylactic vaccination. Here we compare measurement of L1 and L2-specific neutralizing antibodies in human sera using the standard Pseudovirion-Based Neutralization Assay (L1-PBNA) with the newer Furin-Cleaved Pseudovirion-Based Neutralization Assay (FC-PBNA), a modification of the L1-PBNA intended to improve sensitivity towards L2-specific neutralizing antibodies without compromising assay of L1-specific responses. For detection of L1-specific neutralizing antibodies in human sera, the FC- PBNA and L1-PBNA assays showed similar sensitivity and a high level of correlation using WHO standard sera (n = 2), and sera from patients vaccinated with Gardasil (n = 30) or an experimental human papillomavirus type 16 (HPV16) L1 VLP vaccine (n = 70). The detection of L1-specific cross-neutralizing antibodies in these sera using pseudovirions of types phylogenetically-related to those targeted by the L1 virus-like particle (VLP) vaccines was also consistent between the two assays. However, for sera from patients (n = 17) vaccinated with an L2-based immunogen (TA-CIN), the FC-PBNA was more sensitive than the L1-PBNA in detecting L2-specific neutralizing antibodies. Further, the neutralizing antibody titers measured with the FC-PBNA correlated with those determined with the L2-PBNA, another modification of the L1-PBNA that spacio-temporally separates primary and secondary receptor engagement, as well as the protective titers measured using passive transfer studies in the murine genital-challenge model. In sum, the FC-PBNA provided sensitive measurement for both L1 VLP and L2-specific neutralizing antibody in human sera. Vaccination with TA-CIN elicits weak cross-protective antibody in a subset of patients, suggesting the need for an adjuvant.

  4. Specificity and sensitivity of noninvasive measurement of pulmonary vascular protein leak.

    PubMed

    Dauber, I M; Pluss, W T; VanGrondelle, A; Trow, R S; Weil, J V

    1985-08-01

    Noninvasive techniques employing external counting of radiolabeled protein have the potential for measuring pulmonary vascular protein permeability, but their specificity and sensitivity remain unclear. We tested the specificity and sensitivity of a double-radioisotope method by injecting radiolabeled albumin (131I) and erythrocytes (99mTc) into anesthetized dogs and measuring the counts of each isotope for 150 min after injection with an external gamma probe fixed over the lung. We calculated the rate of increase of albumin counts measured by the probe (which reflects the rate at which protein leaks into the extravascular space). To assess permeability we normalized the rate of increase in albumin counts for changes in labeled erythrocyte signal to minimize influence of changes in vascular surface area and thus derived an albumin leak index. We measured the albumin leak index and gravimetric lung water during hydrostatic edema (acutely elevating left atrial pressure by left atrial balloon inflation: mean pulmonary arterial wedge pressure = 22.6 Torr) and in lung injury edema induced by high- (1.0 g/kg) and low-dose (0.25 g/kg) intravenous thiourea. To test specificity we compared hydrostatic and high-dose thiourea edema. The albumin leak index increased nearly fourfold from control after thiourea injury (27.2 +/- 2.3 X 10-4 vs. 7.6 +/- 0.9 X 10-4 min-1) but did not change from control levels after elevating left atrial pressure (8.9 +/- 1.2 X 10-4 min-1) despite comparable increases in gravimetric lung water. To test sensitivity we compared low-dose thiourea with controls. Following low-dose thiourea, the albumin leak index nearly doubled despite the absence of a measurable increase in lung water. We conclude that a noninvasive double radioisotope measurement of pulmonary vascular protein leak, employing external counting techniques and a simplified method of calculation, is specific for lung injury and is also sensitive enough to detect lung injury insufficient to produce detectable pulmonary edema.

  5. Sensitivity and Specificity of Polysomnographic Criteria for Defining Insomnia

    PubMed Central

    Edinger, Jack D.; Ulmer, Christi S.; Means, Melanie K.

    2013-01-01

    Study Objectives: In recent years, polysomnography-based eligibility criteria have been increasingly used to identify candidates for insomnia research, and this has been particularly true of studies evaluating pharmacologic therapy for primary insomnia. However, the sensitivity and specificity of PSG for identifying individuals with insomnia is unknown, and there is no consensus on the criteria sets which should be used for participant selection. In the current study, an archival data set was used to test the sensitivity and specificity of PSG measures for identifying individuals with primary insomnia in both home and lab settings. We then evaluated the sensitivity and specificity of the eligibility criteria employed in a number of recent insomnia trials for identifying primary insomnia sufferers in our sample. Design: Archival data analysis. Settings: Study participants' homes and a clinical sleep laboratory. Participants: Adults: 76 with primary insomnia and 78 non-complaining normal sleepers. Measurements and Results: ROC and cross-tabs analyses were used to evaluate the sensitivity and specificity of PSG-derived total sleep time, latency to persistent sleep, wake after sleep onset, and sleep efficiency for discriminating adults with primary insomnia from normal sleepers. None of the individual criteria accurately discriminated PI from normal sleepers, and none of the criteria sets used in recent trials demonstrated acceptable sensitivity and specificity for identifying primary insomnia. Conclusions: The use of quantitative PSG-based selection criteria in insomnia research may exclude many who meet current diagnostic criteria for an insomnia disorder. Citation: Edinger JD; Ulmer CS; Means MK. Sensitivity and specificity of polysomnographic criteria for defining insomnia. J Clin Sleep Med 2013;9(5):481-491. PMID:23674940

  6. The introduction of umbilical cord lactate measurement and associated neonatal outcomes in a South African tertiary hospital labor ward.

    PubMed

    Allanson, E R; Pattinson, R C; Nathan, E A; Dickinson, J E

    2018-05-01

    To investigate the utility of umbilical artery (UA) lactate measurements in a South African hospital for assessing intrapartum care and predicting neonatal outcomes. From 3 March-12 November 2014, we conducted a prospective cohort study of UA lactate levels at Kalafong Hospital, Pretoria, South Africa. Following birth, a UA blood sample (<0.5uL) was taken from a double-clamped segment of cord and the lactate measured. Maternal and neonatal characteristics and outcomes were recorded. During the study, there were 4668 deliveries; including 1091 emergency cesarean and 154 instrumental deliveries. A lactate was recorded for 946 deliveries (20.3%). 190 babies required neonatal resuscitation, with an optimal cutoff for lactate of 5.45 mmol/L (sensitivity 68%, specificity 72%). 124 babies required nursery admission with the optimal cutoff for lactate 4.95 mmol/L (sensitivity 61%, specificity 59%). 55 babies had an Apgar score <7 at 5 min and the optimal lactate for this outcome was 5.65 mmol/L (sensitivity 64%, specificity of 69%). Umbilical lactate can be used in a middle-low resource setting as a measurement of intrapartum hypoxia, with reasonable sensitivity and specificity for the prediction of, or need for, resuscitation, admission to the nursery, and low Apgar scores.

  7. Differentiation between diverticulitis and colorectal cancer: quantitative CT perfusion measurements versus morphologic criteria--initial experience.

    PubMed

    Goh, Vicky; Halligan, Steve; Taylor, Stuart A; Burling, David; Bassett, Paul; Bartram, Clive I

    2007-02-01

    To determine whether computed tomographic (CT) perfusion measurements in prospectively recruited patients can be used to differentiate between diverticulitis and colorectal cancer and to compare this discrimination with that of standard morphologic criteria. After institutional review board approval and written informed consent were obtained, 60 patients (24 men, 36 women; mean age, 69 years; range, 33.5-90.4 years; 20 patients with cancer, 20 with diverticulitis, and 20 with inactive diverticular disease) underwent CT perfusion imaging at the level of the colonic abnormality, and perfusion parameters were calculated. Analysis of variance was used to investigate any differences in perfusion between the patient groups. Two independent observers also analyzed an abdominopelvic CT study obtained immediately after the CT perfusion study and noted standard morphologic criteria for differential diagnosis. The sensitivity and specificity of CT perfusion measurements for determining the diagnostic category were compared with morphologic criteria by means of multivariate analysis to identify the most discriminatory criteria. Mean blood volume, blood flow, transit time, and permeability were significantly different between patients with cancer and those with diverticulitis (P < .0001); patients with cancer had the highest blood volume, blood flow, and permeability and the shortest transit time. The most discriminatory criteria for determining diagnostic category were blood volume, transit time, permeability, and presence of pericolonic nodes (P = .05, .02, .04, and .02, respectively). Blood volume and blood flow each had a sensitivity of 80% and had specificity of 70% and 75%, respectively, for cancer in comparison with standard morphologic criteria: less than 5 cm of bowel involvement (45% sensitivity, 95% specificity), presence of a mass (85% sensitivity, 90% specificity), pericolonic inflammation (75% sensitivity, 5% specificity), and pericolonic nodes (90% sensitivity, 45% specificity). CT perfusion measurements enable differentiation and better discrimination, in comparison with morphologic criteria, between cancer and diverticulitis. (c) RSNA, 2007.

  8. Theoretical Foundation for Electric-Dipole-Allowed Chiral-Specific Fluorescence Optical Rotary Dispersion (F-ORD) from Interfacial Assemblies.

    PubMed

    Deng, Fengyuan; Ulcickas, James R W; Simpson, Garth J

    2016-11-03

    Fluorescence optical rotary dispersion (F-ORD) is proposed as a novel chiral-specific and interface-specific spectroscopic method. F-ORD measurements of uniaxial assemblies are predicted to be fully electric-dipole-allowed, with corresponding increases in sensitivity to chirality relative to chiral-specific measurements in isotropic assemblies that are commonly interpreted through coupling between electric and magnetic dynamic dipoles. Observations of strong chiral sensitivity in prior single-molecule fluorescence measurements of chiral interfacial molecules are in excellent qualitative agreement with the predictions of the F-ORD mechanism and challenging to otherwise explain. F-ORD may provide methods to suppress background fluorescence in studies of biological interfaces, as the detected signal requires both polar local order and interfacial chirality. In addition, the molecular-level descriptions of the mechanisms underpinning F-ORD may also potentially apply to aid in interpreting chiral-specific Raman and surface-enhanced Raman spectroscopy measurements of uniaxially oriented assemblies, opening up opportunities for chiral-specific and interface-specific vibrational spectroscopy.

  9. An experimental analysis of disgust sensitivity and fear of contagion in Spider and Blood Injection Injury Phobia.

    PubMed

    Bianchi, Kristin N; Carter, Michele M

    2012-10-01

    Disgust sensitivity and concern with contamination have been frequently associated with Spider and Blood-Injection-Injury (BII) Phobias. This study assessed the domain specificity of disgust sensitivity and concern with contamination in 29 Non-Phobic Controls, 25 clinical Spider Phobics, 26 clinical BII Phobics, and 27 persons who met clinical criteria for Spider Phobia and BII Phobia. On self-report measures we found evidence of domain specificity of disgust sensitivity for the Spider and BII Phobia groups. Furthermore, we found that persons with both phobias may be more disgust sensitive than persons with a single phobia. Interestingly, the animal reminder disgust stimulus used in this research was more sensitive to detecting domain specific differences in disgust sensitivity between Phobic groups than was the core disgust stimulus, emphasizing the importance of developing standardized behavioral measures of disgust sensitivity in future research. Lastly, findings from this research suggest that concern with contamination may be more influential in phobic avoidance for persons with Spider Phobia than for persons with BII Phobia. Treatment implications for these findings are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Mobility assessment: Sensitivity and specificity of measurement sets in older adults

    PubMed Central

    Panzer, Victoria P.; Wakefield, Dorothy B.; Hall, Charles B.; Wolfson, Leslie I.

    2011-01-01

    Objective To identify quantitative measurement variables that characterize mobility in older adults, meet reliability and validity criteria, distinguish fall-risk and predict future falls. Design Observational study with 1-year weekly falls follow-up Setting Mobility laboratory Participants Community-dwelling volunteers (n=74; 65–94 years old) categorized at entry as 27 ‘Non-fallers’ or 47 ‘Fallers’ by Medicare criteria (1 injury fall or >1 non-injury falls in the previous year). Interventions None Outcome Measures Test-retest and within-subject reliability, criterion and concurrent validity; predictive ability indicated by observed sensitivity and specificity to entry fall-risk group (Falls-status), Tinetti Performance Oriented Mobility Assessment (POMA), Computerized Dynamic Posturography Sensory Organization Test (SOT) and subsequent falls reported weekly. Results Measurement variables were selected that met reliability (ICC > 0.6) and/or discrimination (p<.01) criteria (Clinical variables- Turn- steps, time, Gait- velocity, Step-in-tub-time, and Downstairs- time; Force plate variables- Quiet standing Romberg ratio sway-area, Maximal lean- anterior-posterior excursion, Sit-to-stand medial-lateral excursion and sway-area). Sets were created (3 clinical, 2 force plate) utilizing combinations of variables appropriate for older adults with different functional activity levels and composite scores were calculated. Scores identified entry Falls-status and concurred with POMA and SOT. The Full clinical set (5 measurement variables) produced sensitivity/specificity (.80/.74) to Falls-status. Composite scores were sensitive and specific in predicting subsequent injury falls and multiple falls compared to Falls-status, POMA or SOT. Conclusions Sets of quantitative measurement variables obtained with this mobility battery provided sensitive prediction of future injury falls and screening for multiple subsequent falls using tasks that should be appropriate to diverse participants. PMID:21621667

  11. Comparison of conventional versus three-dimensional ultrasound in fetal renal pelvis measurement and their potential prediction of neonatal uropathies.

    PubMed

    Duin, L K; Nijhuis, J G; Scherjon, S A; Vossen, M; Willekes, C

    2016-01-01

    To establish a threshold value for fetal renal pelvis dilatation measured by automatic volume calculation (SonoAVC) in the third trimester of pregnancy to predict neonatal uropathies, and to compare these results with conventional antero-posterior (AP) measurement, fetal kidney 3D volume and renal parenchymal thickness. In a prospective cohort study, 125 fetuses with renal pelvis AP diameter of ≥5 mm both at 20 weeks of gestation and in the third trimester, underwent an additional 3D volume measurement of the fetal kidney in the third trimester. Receiver operating characteristic (ROC) curves for establishing threshold values for fetal renal pelvis volume, AP measurement, fetal kidney volume and renal parenchymal thickness to predict neonatal uropathies were analyzed. Also, sensitivity, specificity, area under the curve (AUC) and likelihood ratios were calculated. A cut-off point of 1.58 cm³ was identified in the third trimester of pregnancy (AUC 0.865 (95% CI 0.789-0.940), sensitivity 76.3%, specificity 87.4%, LR+ 6.06, LR- 0.27) for measurements with SonoAVC. A cut-off value of 11.5 mm was established in the third trimester of pregnancy (AUC 0.828 (95% CI 0.737-0.918), sensitivity 71.1%, specificity 85.1%, LR+ 4.77, LR- 0.34) for the conventional AP measurement. A cut-off point for fetal kidney volume was calculated at 13.29 cm³ (AUC 0.769 (95% CI 0.657-0.881), sensitivity 71%, specificity 66%, LR+ 2.09, LR- 0.44). For renal parenchymal thickness, a cut-off point of 8.4 mm was established (AUC 0.216 (95% CI 0.117-0.315), sensitivity 31.6%, specificity 32.6%, LR+ 0.47, LR- 2.10). This study demonstrates that 3D fetal renal pelvis volume measurements and AP measurements both have a good and comparable diagnostic performance, fetal renal volume a fair accuracy and renal parenchymal thickness a poor accuracy in predicting postnatal renal outcome.

  12. The sensitivity and specificity of subjective memory complaints and the subjective memory rating scale, deterioration cognitive observee, mini-mental state examination, six-item screener and clock drawing test in dementia screening.

    PubMed

    Ramlall, S; Chipps, J; Bhigjee, A I; Pillay, B J

    2013-01-01

    The effectiveness of dementia screening depends on the availability of suitable screening tools with good sensitivity and specificity to confidently distinguish normal age-related cognitive decline from dementia. The aim of this study was to evaluate the discriminant validity of 7 screening measures for dementia. A sample of 140 participants aged ≥60 years living in a residential facility for the aged were assessed clinically and assigned caseness for dementia using the Diagnostic and Statistical Manual of Mental Disorders, 4th edition, text revised diagnostic criteria. Sensitivity and specificity of a selection of the following screening measures were tested using receiver operating characteristic (ROC) analysis for individual and combined tests: the Mini-Mental State Examination (MMSE), Six-Item Screener (SIS), Subjective Memory Complaint, Subjective Memory Complaint Clinical (SMCC), Subjective Memory Rating Scale (SMRS), Deterioration Cognitive Observee (DECO) and the Clock Drawing Test (CDT). Using ROC analyses, the SMCC, MMSE and CDT were found to be 'moderately accurate' in screening for dementia with an area under the curve (AUC) >0.70. The AUCs for the SIS (0.526), SMRS (0.661) and DECO (0.687) classified these measures as being 'less accurate'. At recommended cutoff scores, the SMCC had a sensitivity of 90.9% and specificity of 45.7%; the MMSE had a sensitivity of 63.6% and a specificity of 76.0%, and the CDT had a sensitivity of 44.4% and a specificity of 88.9%. Combining the SMCC and MMSE did not improve their predictive power except for a modest increase when using the sequential rule. The SMCC is composed of valid screening questions that have high sensitivity, are simple to administer and ideal for administration at the community or primary health care level as a first level of 'rule-out' screening. The MMSE can be included at a second stage of screening at the general hospital level and the CDT in specialist clinical settings. Sequential use of the SMCC and MMSE will improve the specificity of the former and the sensitivity of the latter. Copyright © 2013 S. Karger AG, Basel.

  13. The predictive value of magnetic resonance imaging of retinoblastoma for the likelihood of high-risk pathologic features.

    PubMed

    Hiasat, Jamila G; Saleh, Alaa; Al-Hussaini, Maysa; Al Nawaiseh, Ibrahim; Mehyar, Mustafa; Qandeel, Monther; Mohammad, Mona; Deebajah, Rasha; Sultan, Iyad; Jaradat, Imad; Mansour, Asem; Yousef, Yacoub A

    2018-06-01

    To evaluate the predictive value of magnetic resonance imaging in retinoblastoma for the likelihood of high-risk pathologic features. A retrospective study of 64 eyes enucleated from 60 retinoblastoma patients. Contrast-enhanced magnetic resonance imaging was performed before enucleation. Main outcome measures included demographics, laterality, accuracy, sensitivity, and specificity of magnetic resonance imaging in detecting high-risk pathologic features. Optic nerve invasion and choroidal invasion were seen microscopically in 34 (53%) and 28 (44%) eyes, respectively, while they were detected in magnetic resonance imaging in 22 (34%) and 15 (23%) eyes, respectively. The accuracy of magnetic resonance imaging in detecting prelaminar invasion was 77% (sensitivity 89%, specificity 98%), 56% for laminar invasion (sensitivity 27%, specificity 94%), 84% for postlaminar invasion (sensitivity 42%, specificity 98%), and 100% for optic cut edge invasion (sensitivity100%, specificity 100%). The accuracy of magnetic resonance imaging in detecting focal choroidal invasion was 48% (sensitivity 33%, specificity 97%), and 84% for massive choroidal invasion (sensitivity 53%, specificity 98%), and the accuracy in detecting extrascleral extension was 96% (sensitivity 67%, specificity 98%). Magnetic resonance imaging should not be the only method to stratify patients at high risk from those who are not, eventhough it can predict with high accuracy extensive postlaminar optic nerve invasion, massive choroidal invasion, and extrascleral tumor extension.

  14. Validation and Comparison of Accelerometers Worn on the Hip, Thigh, and Wrists for Measuring Physical Activity and Sedentary Behavior.

    PubMed

    Montoye, Alexander H K; Pivarnik, James M; Mudd, Lanay M; Biswas, Subir; Pfeiffer, Karin A

    2016-01-01

    Recent evidence suggests that physical activity (PA) and sedentary behavior (SB) exert independent effects on health. Therefore, measurement methods that can accurately assess both constructs are needed. To compare the accuracy of accelerometers placed on the hip, thigh, and wrists, coupled with machine learning models, for measurement of PA intensity category (SB, light-intensity PA [LPA], and moderate- to vigorous-intensity PA [MVPA]) and breaks in SB. Forty young adults (21 female; age 22.0 ± 4.2 years) participated in a 90-minute semi-structured protocol, performing 13 activities (three sedentary, 10 non-sedentary) for 3-10 minutes each. Participants chose activity order, duration, and intensity. Direct observation (DO) was used as a criterion measure of PA intensity category, and transitions from SB to a non-sedentary activity were breaks in SB. Participants wore four accelerometers (right hip, right thigh, and both wrists), and a machine learning model was created for each accelerometer to predict PA intensity category. Sensitivity and specificity for PA intensity category classification were calculated and compared across accelerometers using repeated measures analysis of variance, and the number of breaks in SB was compared using repeated measures analysis of variance. Sensitivity and specificity values for the thigh-worn accelerometer were higher than for wrist- or hip-worn accelerometers, > 99% for all PA intensity categories. Sensitivity and specificity for the hip-worn accelerometer were 87-95% and 93-97%. The left wrist-worn accelerometer had sensitivities and specificities of > 97% for SB and LPA and 91-95% for MVPA, whereas the right wrist-worn accelerometer had sensitivities and specificities of 93-99% for SB and LPA but 67-84% for MVPA. The thigh-worn accelerometer had high accuracy for breaks in SB; all other accelerometers overestimated breaks in SB. Coupled with machine learning modeling, the thigh-worn accelerometer should be considered when objectively assessing PA and SB.

  15. Relationship between the surrogate anthropometric measures, foot length and chest circumference and birth weight among newborns of Sarlahi, Nepal

    PubMed Central

    Mullany, LC; Darmstadt, GL; Khatry, SK; LeClerq, SC; Tielsch, JM

    2008-01-01

    Background Classification of infants into low birth weight (LBW, <2500 g) or very low birth weight (VLBW, <2000 g) categories is a crucial step in targeting interventions to high-risk infants. Objective To compare the validity of chest circumference and foot length as surrogate anthropometric measures for the identification of LBW and VLBW infants. Subjects and setting Newborn infants (n = 1640) born between March and June 2004 in 30 Village Development Committees of Sarlahi district, Nepal. Design Chest circumference, foot length and weight (SECA 727, precise to 2 g) of newborns were measured within 72 h after birth. The sensitivity, specificity and predictive values for a range of cutoff points of the anthropometric measures were estimated using the digital scale measurements as the gold standard. Results Among LBW infants (469/1640, 28.6%), chest circumference measures <30.3 cm were 91% sensitive and 83% specific. Similar levels of sensitivity for foot length were achieved only with considerable loss of specificity (<45%). Foot length measurements <6.9 cm were 88% sensitive and 86% specific for the identification of VLBW infants. Conclusion Chest circumference was superior to foot length in classification of infants into birth weight categories. For the identification of VLBW infants, foot length performed well, and may be preferable to chest circumference, as the former measure does not require removal of infant swaddling clothes. In the absence of more precise direct measures of birth weight, chest circumference is recommended over foot length for the identification of LBW infants. Sponsorship The National Institute of Child Health and Human Development; the Saving Newborn Lives Initiative, Save the Children – US and the Office of Heath and Nutrition, United States Agency for International Development (see Acknowledgements). PMID:16885929

  16. Sensitivity and specificity of a brief personality screening instrument in predicting future substance use, emotional, and behavioral problems: 18-month predictive validity of the Substance Use Risk Profile Scale.

    PubMed

    Castellanos-Ryan, Natalie; O'Leary-Barrett, Maeve; Sully, Laura; Conrod, Patricia

    2013-01-01

    This study assessed the validity, sensitivity, and specificity of the Substance Use Risk Profile Scale (SURPS), a measure of personality risk factors for substance use and other behavioral problems in adolescence. The concurrent and predictive validity of the SURPS was tested in a sample of 1,162 adolescents (mean age: 13.7 years) using linear and logistic regressions, while its sensitivity and specificity were examined using the receiver operating characteristics curve analyses. Concurrent and predictive validity tests showed that all 4 brief scales-hopelessness (H), anxiety sensitivity (AS), impulsivity (IMP), and sensation seeking (SS)-were related, in theoretically expected ways, to measures of substance use and other behavioral and emotional problems. Results also showed that when using the 4 SURPS subscales to identify adolescents "at risk," one can identify a high number of those who developed problems (high sensitivity scores ranging from 72 to 91%). And, as predicted, because each scale is related to specific substance and mental health problems, good specificity was obtained when using the individual personality subscales (e.g., most adolescents identified at high risk by the IMP scale developed conduct or drug use problems within the next 18 months [a high specificity score of 70 to 80%]). The SURPS is a valuable tool for identifying adolescents at high risk for substance misuse and other emotional and behavioral problems. Implications of findings for the use of this measure in future research and prevention interventions are discussed. Copyright © 2012 by the Research Society on Alcoholism.

  17. The Detection of Protein via ZnO Resonant Raman Scattering Signal

    NASA Astrophysics Data System (ADS)

    Shan, Guiye; Yang, Guoliang; Wang, Shuang; Liu, Yichun

    2008-03-01

    Detecting protein with high sensitivity and specificity is essential for disease diagnostics, drug screening and other application. Semiconductor nanoparticles show better properties than organic dye molecules when used as markers for optical measurements. We used ZnO nanoparticles as markers for detecting protein in resonant Raman scattering measurements. The highly sensitive detection of proteins was achieved by an antibody-based sandwich assay. A probe for the target protein was constructed by binding the ZnO/Au nanoparticles to a primary antibody by eletrostatic interaction between Au and the antibody. A secondary antibody, which could be specifically recognized by target protein, was attached to a solid surface. The ZnO/Au-antibody probe could specifically recognize and bind to the complex of the target protein and secondary antibody. Our measurements using the resonant Raman scattering signal of ZnO nanoparticles showed good selectivity and sensitivity for the target protein.

  18. Sensitivity and Specificity in Three Measures of Depression Among Mexican American Women.

    PubMed

    Valencia-Garcia, Dellanira; Bi, Xiaoyu; Ayón, Cecilia

    2017-06-01

    This paper examined the prevalence of depressive symptomotology among women of Mexican ancestry (N = 205), over the age of 18, of diverse incomes and nativity. We examined differences in rates of diagnosis by Spanish/English preference and the sensitivity and specificity of three common measures: the Patient Health Questionnaire (PHQ9), the Kessler Psychological Distress Scale (K-10), and depression questions from the Composite International Diagnostic Interview, Short Form (MDD CIDI-SF); PHQ9 was used as the "gold standard" measure. Results indicated 18-32 % of participants met criteria for depression with higher rates found among Spanish preference participants. The K-10 had significantly higher sensitivity (0.81) but lower specificity (0.79) than the MDD CIDI-SF items (0.57 and 0.89, respectively). This study suggests that the K-10 and MDD CIDI-SF measures are complementary to each other for screening of depressive symptomatology. Implications for cultural and linguistic assessment of depression are further discussed.

  19. Sensitivity of some tests for alcohol abuse : findings in nonalcoholics recovering from intoxication.

    DOT National Transportation Integrated Search

    1983-01-01

    A variety of measurements are sensitive to alcoholism; some may be applicable to screening programs, but more precise knowledge of sensitivity and specificity would help to select a minimal test battery. This study assessed the sensitivity of some te...

  20. Critical comparison of diffuse reflectance spectroscopy and colorimetry as dermatological diagnostic tools for acanthosis nigricans: a chemometric approach.

    PubMed

    Devpura, Suneetha; Pattamadilok, Bensachee; Syed, Zain U; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J; Hamzavi, Iltefat; Lim, Henry W; Naik, Ratna

    2011-06-01

    Quantification of skin changes due to acanthosis nigricans (AN), a disorder common among insulin-resistant diabetic and obese individuals, was investigated using two optical techniques: diffuse reflectance spectroscopy (DRS) and colorimetry. Measurements were obtained from AN lesions on the neck and two control sites of eight AN patients. A principal component/discriminant function analysis successfully differentiated between AN lesion and normal skin with 87.7% sensitivity and 94.8% specificity in DRS measurements and 97.2% sensitivity and 96.4% specificity in colorimetry measurements.

  1. Sensitivity of Hyperdense Basilar Artery Sign on Non-Enhanced Computed Tomography.

    PubMed

    Ernst, Marielle; Romero, Javier M; Buhk, Jan-Hendrik; Cheng, Bastian; Herrmann, Jochen; Fiehler, Jens; Groth, Michael

    2015-01-01

    The hyperdense basilar artery sign (HBAS) is an indicator of vessel occlusion on non contrast-enhanced computer tomography (NECT) in acute stroke patients. Since basilar artery occlusion (BAO) is associated with a high mortality and morbidity, its early detection is of great clinical value. We sought to analyze the influence of density measurement as well as a normalized ratio of Hounsfield unit/hematocrit (HU/Hct) ratio on the detection of BAO on NECT in patients with suspected BAO. 102 patients with clinically suspected BAO were examined with NECT followed immediately by Multidetector computed tomography Angiography. Two observers independently analyzed the images regarding the presence or absence of HBAS on NECT and performed HU measurements in the basilar artery. Receiver operating characteristic curve analysis was performed to determine the optimal density threshold for BAO using attenuation measurements or HU/Hct ratio. Sensitivity of visual detection of the HBAS on NECT was relatively low 81% (95%-CI, 54-95%) while specificity was high 91% (95%-CI, 82-96%). The highest sensitivity was achieved by the combination of visual assessment and additional quantitative attenuation measurements applying a cut-off value of 46.5 HU with 94% sensitivity and 81% specificity for BAO. A HU/Hct ratio >1.32 revealed sensitivity of 88% (95%-CI, 60-98%) and specificity of 84% (95%-CI, 74-90%). In patients with clinically suspected acute BAO the combination of visual assessment and additional attenuation measurement with a cut-off value of 46.5 HU is a reliable approach with high sensitivity in the detection of BAO on NECT.

  2. Transcranial magnetic stimulation distinguishes Alzheimer disease from frontotemporal dementia.

    PubMed

    Benussi, Alberto; Di Lorenzo, Francesco; Dell'Era, Valentina; Cosseddu, Maura; Alberici, Antonella; Caratozzolo, Salvatore; Cotelli, Maria Sofia; Micheli, Anna; Rozzini, Luca; Depari, Alessandro; Flammini, Alessandra; Ponzo, Viviana; Martorana, Alessandro; Caltagirone, Carlo; Padovani, Alessandro; Koch, Giacomo; Borroni, Barbara

    2017-08-15

    To determine whether a transcranial magnetic stimulation (TMS) multiparadigm approach can be used to distinguish Alzheimer disease (AD) from frontotemporal dementia (FTD). Paired-pulse TMS was used to investigate short-interval intracortical inhibition (SICI) and facilitation (ICF), long-interval intracortical inhibition, and short-latency afferent inhibition (SAI) to measure the activity of different intracortical circuits in patients with AD, patients with FTD, and healthy controls (HC). The primary outcome measures were sensitivity and specificity of TMS measures, derived from receiver operating curve analysis. A total of 175 participants met the inclusion criteria. We diagnosed 79 patients with AD, 64 patients with FTD, and 32 HC. We found that while patients with AD are characterized by a specific impairment of SAI, FTD shows a remarkable dysfunction of SICI-ICF intracortical circuits. With the use of the best indexes, TMS differentiated FTD from AD with a sensitivity of 91.8% and specificity of 88.6%, AD from HC with a sensitivity of 84.8% and specificity of 90.6%, and FTD from HC with a sensitivity of 90.2% and specificity of 78.1%. These results were confirmed in patients with mild disease. TMS is a noninvasive procedure that reliably distinguishes AD from FTD and HC and, if these findings are replicated in larger studies, could represent a useful additional diagnostic tool for clinical practice. This study provides Class III evidence that TMS measures can distinguish patients with AD from those with FTD. © 2017 American Academy of Neurology.

  3. Is there a place for extended assessments in addressing child sexual abuse allegations? How sensitivity and specificity impact professional perspectives.

    PubMed

    Williams, Javonda; Nelson-Gardell, Debra; Coulborn Faller, Kathleen; Tishelman, Amy; Cordisco-Steele, Linda

    2014-01-01

    Using data from a survey of perceptions of 932 child welfare professionals about the utility of extended assessments, the researchers constructed a scale to measure respondents' views about sensitivity (ensuring sexually abused children are correctly identified) and specificity (ensuring nonabused children are correctly identified) in child sexual abuse evaluations. On average, respondents scored high (valuing sensitivity) on the sensitivity versus specificity scale. Next, the researchers undertook bivariate analyses to identify independent variables significantly associated with the sensitivity versus specificity scale. Then those variables were entered into a multiple regression. Four independent variables were significantly related to higher sensitivity scores: encountering cases requiring extended assessments, valuing extended assessments among scarce resources, less concern about proving cases in court, and viewing the goal of extended assessments as understanding needs of child and family (adjusted R2 = .34).

  4. Microarray-based IgE detection in tears of patients with vernal keratoconjunctivitis.

    PubMed

    Leonardi, Andrea; Borghesan, Franco; Faggian, Diego; Plebani, Mario

    2015-11-01

    A specific allergen sensitization can be demonstrated in approximately half of the vernal keratoconjunctivitis (VKC) patients by conventional allergic tests. The measurement of specific IgE in tears using a multiplex allergen microarray may offer advantages to identify local sensitization to a specific allergen. In spring-summer 2011, serum and tears samples were collected from 10 active VKC patients (three females, seven males) and 10 age-matched normal subjects. Skin prick test, symptoms score and full ophthalmological examination were performed. Specific serum and tear IgE were assayed using ImmunoCAP ISAC, a microarray containing 103 components derived from 47 allergens. Normal subjects resulted negative for the presence of specific IgE both in serum and in tears. Of the 10 VKC patients, six resulted positive to specific IgE in serum and/or tears. In three of these six patients, specific IgE was found positive only in tears. Cross-reactivity between specific markers was found in three patients. Grass, tree, mites, animal but also food allergen-specific IgE were found in tears. Conjunctival provocation test performed out of season confirmed the specific local conjunctival reactivity. Multiple specific IgE measurements with single protein allergens using a microarray technique in tear samples are a useful, simple and non-invasive diagnostic tool. ImmunoCAP ISAC detects allergen sensitization at component level and adds important information by defining both cross- and co-sensitization to a large variety of allergen molecules. The presence of specific IgE only in tears of VKC patients reinforces the concept of possible local sensitization. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Predictive models of lameness in dairy cows achieve high sensitivity and specificity with force measurements in three dimensions.

    PubMed

    Dunthorn, Jason; Dyer, Robert M; Neerchal, Nagaraj K; McHenry, Jonathan S; Rajkondawar, Parimal G; Steingraber, Gary; Tasch, Uri

    2015-11-01

    Lameness remains a significant cause of production losses, a growing welfare concern and may be a greater economic burden than clinical mastitis . A growing need for accurate, continuous automated detection systems continues because US prevalence of lameness is 12.5% while individual herds may experience prevalence's of 27.8-50.8%. To that end the first force-plate system restricted to the vertical dimension identified lame cows with 85% specificity and 52% sensitivity. These results lead to the hypothesis that addition of transverse and longitudinal dimensions could improve sensitivity of lameness detection. To address the hypothesis we upgraded the original force plate system to measure ground reaction forces (GRFs) across three directions. GRFs and locomotion scores were generated from randomly selected cows and logistic regression was used to develop a model that characterised relationships of locomotion scores to the GRFs. This preliminary study showed 76 variables across 3 dimensions produced a model with greater than 90% sensitivity, specificity, and area under the receiver operating curve (AUC). The result was a marked improvement on the 52% sensitivity, and 85% specificity previously observed with the 1 dimensional model or the 45% sensitivities reported with visual observations. Validation of model accuracy continues with the goal to finalise accurate automated methods of lameness detection.

  6. The role of disgust in patients with hypochondriasis.

    PubMed

    Weck, Florian; Esch, Sebastian; Rohrmann, Sonja

    2014-01-01

    Theoretically, disgust sensitivity and disgust proneness could play an important role in hypochondriasis, since disgust is a defensive emotion widely believed to protect the organism from illness. However, empirical evidence to support this hypothesis has so far been based only on nonclinical samples, so that the importance and specificity of disgust for hypochondriasis remains unclear. In the current study, 36 patients with hypochondriasis, 27 with an anxiety disorder, and 29 healthy controls completed several measures which included the assessment of disgust sensitivity (Scale for the Assessment of Disgust Sensitivity) and disgust proneness (Questionnaire for the Assessment of Disgust Proneness). We found that patients with hypochondriasis and those with an anxiety disorder had higher scores than those of the healthy controls for several measures of disgust proneness. Moreover, measures of hypochondriacal characteristics were associated with those of disgust proneness and disgust sensitivity. However, no differences were found between patients with hypochondriasis and those with anxiety disorders, with respect to disgust proneness and disgust sensitivity. Therefore, it can be assumed that disgust proneness and disgust sensitivity seem to be less specific than previously suggested for the development and maintenance of hypochondriasis.

  7. Non-invasive assessment of peripheral arterial disease: Automated ankle brachial index measurement and pulse volume analysis compared to duplex scan.

    PubMed

    Lewis, Jane Ea; Williams, Paul; Davies, Jane H

    2016-01-01

    This cross-sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (1) ankle brachial index and (2) pulse volume waveform analysis recorded by the same automated device, with the presence or absence of peripheral arterial disease being verified by ultrasound duplex scan. Patients (n=205) referred for lower limb arterial assessment underwent ankle brachial index measurement and pulse volume waveform recording using volume plethysmography, followed by ultrasound duplex scan. The presence of peripheral arterial disease was recorded if ankle brachial index <0.9; pulse volume waveform was graded as 2, 3 or 4; or if haemodynamically significant stenosis >50% was evident with ultrasound duplex scan. Outcome measure was agreement between the measured ankle brachial index and interpretation of pulse volume waveform for peripheral arterial disease diagnosis, using ultrasound duplex scan as the reference standard. Sensitivity of ankle brachial index was 79%, specificity 91% and overall accuracy 88%. Pulse volume waveform sensitivity was 97%, specificity 81% and overall accuracy 85%. The combined sensitivity of ankle brachial index and pulse volume waveform was 100%, specificity 76% and overall accuracy 85%. Combining these two diagnostic modalities within one device provided a highly accurate method of ruling out peripheral arterial disease, which could be utilised in primary care to safely reduce unnecessary secondary care referrals.

  8. [Sensitivity and specificity of flicker perimetry with Pulsar. Comparison with achromatic (white-on-white) perimetry in glaucoma patients].

    PubMed

    Göbel, K; Erb, C

    2013-02-01

    The early detection of functional glaucoma damage plays an increasingly more central role in the diagnosis and treatment of glaucoma disease. Using selective perimetry detection of early glaucomatous defects is more likely and one of these methods is flicker perimetry with Pulsar. Flicker perimetry is used to analyze the temporal visual function in combination with spatial resolution and contrast sensitivity as opposed to standard automated perimetry which measures the differential light sensitivity with a non-specific stimulus. This study showed a higher sensitivity and specificity of Pulsar perimetry in comparison to achromatic perimetry in glaucoma patients.

  9. Macular Diagnostic Ability in OCT for Assessing Glaucoma in High Myopia.

    PubMed

    Hung, Kuo-Chi; Wu, Pei-Chang; Poon, Yi-Chieh; Chang, Hsueh-Wen; Lai, Ing-Chou; Tsai, Jen-Chia; Lin, Pei-Wen; Teng, Mei-Ching

    2016-02-01

    To compare the diagnostic abilities of spectral-domain optical coherence tomography (SD-OCT; Spectralis OCT) and time-domain OCT (TD-OCT; Stratus OCT). Changes in macular parameters in highly myopic eyes of glaucoma patients and highly myopic eyes of glaucoma suspects were evaluated and compared. We collected data from 72 highly myopic eyes (spherical equivalent, ≤-6.0D). Forty-one eyes had perimetric glaucoma and 31 eyes were suspected to have glaucoma (control group). All eyes underwent SD-OCT and TD-OCT imaging. Area under the receiver operating characteristic (AUROC) curve and sensitivity were examined on macular volume and thickness parameters at a fixed specificity and compared between groups. The highest TD-OCT AUROC curves were found using outer inferior sector macular thickness (AUROC curve, 0.911) and volume (AUROC curve, 0.909). The highest SD-OCT AUROC curves were found using outer inferior region thickness (AUROC curve, 0.836) and volume (AUROC curve, 0.834). The difference between the two imaging modalities was not statistically significant (thickness, p = 0.141; volume, p = 0.138). The sensitivity of TD-OCT macular outer inferior average thickness was highest and was 88.2%, with a specificity of 80.4%. The sensitivity of TD-OCT average volume measurements in this same region was 76.5%, with a specificity of 91.3%. The SD-OCT average thickness measurements also had the highest sensitivity in this region, which was 78.6%, with a specificity of 82.1%. The SD-OCT volume measurements had a sensitivity of 67.9%, with a specificity of 92.3%. Both SD-OCT and TD-OCT measurements of outer inferior macular thickness and volume can differentiate between eyes of glaucoma patients and glaucoma suspects with high myopia. These independent predictors all had good sensitivity. Based on our results, SD-OCT and TD-OCT have similar diagnostic abilities. These parameters may provide useful additional data in highly myopic eyes to complement standard glaucoma diagnosis tools.

  10. Assessment of nasalance and nasality in patients with a repaired cleft palate.

    PubMed

    Sinko, Klaus; Gruber, Maike; Jagsch, Reinhold; Roesner, Imme; Baumann, Arnulf; Wutzl, Arno; Denk-Linnert, Doris-Maria

    2017-07-01

    In patients with a repaired cleft palate, nasality is typically diagnosed by speech language pathologists. In addition, there are various instruments to objectively diagnose nasalance. To explore the potential of nasalance measurements after cleft palate repair by NasalView ® , we correlated perceptual nasality and instrumentally measured nasalance of eight speech items and determined the relationship between sensitivity and specificity of the nasalance measures by receiver-operating characteristics (ROC) analyses and AUC (area under the curve) computation for each single test item and specific item groups. We recruited patients with a primarily repaired cleft palate receiving speech therapy during follow-up. During a single day visit, perceptive and instrumental assessments were obtained in 36 patients and analyzed. The individual perceptual nasality was assigned to one of four categories; the corresponding instrumental nasalance measures for the eight specific speech items were expressed on a metric scale (1-100). With reference to the perceptual diagnoses, we observed 3 nasal and one oral test item with high sensitivity. However, the specificity of the nasality indicating measures was rather low. The four best speech items with the highest sensitivity provided scores ranging from 96.43 to 100%, while the averaged sensitivity of all eight items was below 90%. We conclude that perceptive evaluation of nasality remains state of the art. For clinical follow-up, instrumental nasalance assessment can objectively document subtle changes by analysis of four speech items only. Further studies are warranted to determine the applicability of instrumental nasalance measures in the clinical routine, using discriminative items only.

  11. Temperature measurement in the adult emergency department: oral, tympanic membrane and temporal artery temperatures versus rectal temperature.

    PubMed

    Bijur, Polly E; Shah, Purvi D; Esses, David

    2016-12-01

    The objective was to compare agreement between three non-invasive measures of temperature and rectal temperatures and to estimate the sensitivity and specificity of these measures to detect a rectal temperature of 38°C or higher. We conducted a study of the diagnostic accuracy of oral, tympanic membrane (TM) and temporal artery (TA) thermometry to measure fever in an urban emergency department (ED). Data were collected from adult patients who received rectal temperature measurement. Bland-Altman analysis was performed; sensitivity, specificity and 95% CIs were calculated. 987 patients were enrolled. 36% of the TM and TA readings differed by 0.5°C or more from rectal temperatures, 50% of oral temperatures. TM measures were most precise-the SD of the difference from rectal was 0.4°C TM, and 0.6°C for oral and TA (p<0.001). The sensitivities of a 38°C cutpoint on oral, TM and TA measures to detect a rectal temperature of 38°C or higher were: 37.0%, 68.3% and 71.1%, respectively (oral vs TM and TA p<0.001). The corresponding specificities were 99.4%, 98.2% and 92.3% (oral, TM and TA) with oral specificity significantly higher than the other two methods (p<0.01). TM and TA cutpoints of 37.5°C provided greater than 90% sensitivity to detect fever with specificity of 90% and 72%, respectively. None of the non-invasive methods met benchmarks for diagnostic accuracy using the criterion of 38°C to detect rectal temperature of 38°C. A TM cutpoint of 37.5°C provides maximum diagnostic accuracy of the three non-invasive measures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Magnetic relaxometry as applied to sensitive cancer detection and localization

    DOE PAGES

    De Haro, Leyma P.; Karaulanov, Todor; Vreeland, Erika C.; ...

    2015-06-02

    Abstract Here we describe superparamagnetic relaxometry (SPMR), a technology that utilizes highly sensitive magnetic sensors and superparamagnetic nanoparticles for cancer detection. Using SPMR, we sensitively and specifically detect nanoparticles conjugated to biomarkers for various types of cancer. SPMR offers high contrast In SPMR measurements, a brief magnetizing pulse is used to align superparamagnetic nanoparticles of a discrete size. Following the pulse, an array of superconducting quantum interference detectors (SQUID) sensors detect the decaying magnetization field. NP size is chosen so that, when bound, the induced field decays in seconds. They are functionalized with specific biomarkers and incubated with cancer cellsmore » As a result, superparamagnetic NPs developed here have small size dispersion. Cell incubation studies measure specificity for different cell lines and antibodies with very high contrast.« less

  13. The sensitivity and specificity of thermometry and plethysmography in the assessment of hand-arm vibration syndrome.

    PubMed

    Thompson, Aaron; House, Ron; Manno, Michael

    2008-05-01

    Finger plethysmography and thermometry are objective measures used to assess the vascular aspect of hand-arm vibration syndrome (HAVS). Research to date shows poor correlation between these tests and Stockholm Workshop Scale (SWS) vascular stage. Clinicians, researchers and compensation boards require objective means to diagnose and quantify HAVS. To define the specificity and sensitivity of thermometry and plethysmography using the SWS as the reference criterion. A secondary goal was to consider cut points for the tests optimizing sensitivity and specificity. A cross-sectional analysis was conducted on HAVS patients seen at an occupational medicine specialty clinic. Plethysmography and thermometry were analyzed using SWS vascular stage as the outcome variable. Logistic regression controlled for age, smoking and time since last vibration exposure and use of vasoactive medications. The sensitivity and specificity of the combined tests were calculated using varying cut points. A total of 139 patients consented to participate in the study. Plethysmography stage 1 or greater showed the highest sensitivity (sensitivity 94% and specificity 15%). Specificity was optimized combining plethysmography stage 3 and thermometry stage 3 (specificity 98% and sensitivity 23%). Maximal diagnostic accuracy was achieved by plethysmography alone setting the criteria for a positive test as being stage 1 or greater (70%). Neither plethysmography nor thermometry either alone or in combination demonstrated sufficient sensitivity and specificity to serve as an objective correlate for SWS vascular stage. All combinations of plethysmography and thermometry showed a lower specificity than sensitivity indicating that the SWS may be less sensitive in detecting vascular pathology than the objective tests.

  14. Single measure and gated screening approaches for identifying students at-risk for academic problems: Implications for sensitivity and specificity.

    PubMed

    Van Norman, Ethan R; Nelson, Peter M; Klingbeil, David A

    2017-09-01

    Educators need recommendations to improve screening practices without limiting students' instructional opportunities. Repurposing previous years' state test scores has shown promise in identifying at-risk students within multitiered systems of support. However, researchers have not directly compared the diagnostic accuracy of previous years' state test scores with data collected during fall screening periods to identify at-risk students. In addition, the benefit of using previous state test scores in conjunction with data from a separate measure to identify at-risk students has not been explored. The diagnostic accuracy of 3 types of screening approaches were tested to predict proficiency on end-of-year high-stakes assessments: state test data obtained during the previous year, data from a different measure administered in the fall, and both measures combined (i.e., a gated model). Extant reading and math data (N = 2,996) from 10 schools in the Midwest were analyzed. When used alone, both measures yielded similar sensitivity and specificity values. The gated model yielded superior specificity values compared with using either measure alone, at the expense of sensitivity. Implications, limitations, and ideas for future research are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Comparison of the Repeatable Battery for the Assessment of Neuropsychological Status Effort Scale and Effort Index in a Dementia Sample†

    PubMed Central

    Dunham, Kathryn J.; Shadi, Sarah; Sofko, Channing A.; Denney, Robert L.; Calloway, Jordan

    2014-01-01

    The aim of the current study was to compare two embedded measures of effort for the repeatable battery for the assessment of neuropsychological status (RBANS). Sensitivity and specificity of the Effort Index (EI) and Effort Scale (ES) were compared in a sample of individuals with genuine memory impairment (MI) and individuals coached to simulate MI. Overall, the EI yielded a sensitivity of 0.89 and specificity of 0.41, while the ES yielded a sensitivity of 0.88 and specificity of 0.81. When those in the MI group were separated by level of impairment, the EI was more specific when RBANS Total Scores were in the average or mildly impaired range, and the ES had greater specificity when RBANS Total Scores were in the severely impaired range. These results suggest that the embedded measure should be selected based on the level of impairment on the RBANS. PMID:25236719

  16. Sensitivity and Specificity of Self-Reported Olfactory Function in a Home-Based Study of Independent-Living, Healthy Older Women

    PubMed Central

    Rawal, Shristi; Hoffman, Howard J.; Chapo, Audrey K.

    2015-01-01

    Introduction The 2011–14 US National Health and Nutrition Examination Survey chemosensory protocol asks adults to self-rate their orthonasal (via nostrils) and retronasal (via mouth) smell abilities for subsequent odor identification testing. From data collected with a similar protocol, we aimed to identify a self-reported olfactory index that showed the best sensitivity (correctly identifying dysfunction) and specificity (correctly indentifying normosmia) with measured olfaction. Methods In home-based testing, 121 independent-living older women (age 73±7 years) reported their olfactory function by interviewer-administered survey. Olfactory function was measured orthonasally via composite (odor threshold, identification task) or identification task alone. Results Only 16 % of women self-rated “below average” smell function. More women perceived loss of smell (38 %) or flavor (30 %) with aging. The rate of measured dysfunction was 30 % by composite (threshold and identification) and 21.5 % by identification task, the latter misclassifying some mild dysfunction as normosmia. An index of self-rated smell function and perceived loss yielded the most favorable sensitivity (65 %) and specificity (77 %) to measured function. Self-rated olfaction showed better agreement with severe measured dysfunction; mild dysfunction was less noticed. Conclusions Self-reported indices that query about current and perceived changes in smell and flavor with aging showed better sensitivity estimates than those previously reported. Specificity was somewhat lower—some older adults may correctly perceive loss unidentified in a single assessment, or have a retronasal impairment that was undetected by an orthonasal measure. Implications Our findings should inform self-rated measures that screen for severe olfactory dysfunction in clinical/community settings where testing is not routine. PMID:25866597

  17. Assessment of Relationship-Specific Incentive and Threat Sensitivities: Predicting Satisfaction and Affect in Adult Intimate Relationships

    ERIC Educational Resources Information Center

    Laurenceau, Jean-Philippe; Kleinman, Brighid M.; Kaczynski, Karen J.; Carver, Charles S.

    2010-01-01

    Self-report scales assessing relationship-specific incentive and threat sensitivity were created. Initial tests of factor structure and associations with relationship quality were conducted in a sample of persons in intimate relationships (Study 1). Associations with conceptually related measures were examined to determine convergent and…

  18. Quantitative image cytometry measurements of lipids, DNA, CD45 and cytokeratin for circulating tumor cell identification in a model system

    NASA Astrophysics Data System (ADS)

    Futia, Gregory L.; Qamar, Lubna; Behbakht, Kian; Gibson, Emily A.

    2016-04-01

    Circulating tumor cell (CTC) identification has applications in both early detection and monitoring of solid cancers. The rarity of CTCs, expected at ~1-50 CTCs per million nucleated blood cells (WBCs), requires identifying methods based on biomarkers with high sensitivity and specificity for accurate identification. Discovery of biomarkers with ever higher sensitivity and specificity to CTCs is always desirable to potentially find more CTCs in cancer patients thus increasing their clinical utility. Here, we investigate quantitative image cytometry measurements of lipids with the biomarker panel of DNA, Cytokeratin (CK), and CD45 commonly used to identify CTCs. We engineered a device for labeling suspended cell samples with fluorescent antibodies and dyes. We used it to prepare samples for 4 channel confocal laser scanning microscopy. The total data acquired at high resolution from one sample is ~ 1.3 GB. We developed software to perform the automated segmentation of these images into regions of interest (ROIs) containing individual cells. We quantified image features of total signal, spatial second moment, spatial frequency second moment, and their product for each ROI. We performed measurements on pure WBCs, cancer cell line MCF7 and mixed samples. Multivariable regressions and feature selection were used to determine combination features that are more sensitive and specific than any individual feature separately. We also demonstrate that computation of spatial characteristics provides higher sensitivity and specificity than intensity alone. Statistical models allowed quantification of the required sensitivity and specificity for detecting small levels of CTCs in a human blood sample.

  19. Reliable change, sensitivity, and specificity of a multidimensional concussion assessment battery: implications for caution in clinical practice.

    PubMed

    Register-Mihalik, Johna K; Guskiewicz, Kevin M; Mihalik, Jason P; Schmidt, Julianne D; Kerr, Zachary Y; McCrea, Michael A

    2013-01-01

    To provide reliable change confidence intervals for common clinical concussion measures using a healthy sample of collegiate athletes and to apply these reliable change parameters to a sample of concussed collegiate athletes. Two independent samples were included in the study and evaluated on common clinical measures of concussion. The healthy sample included male, collegiate football student-athletes (n = 38) assessed at 2 time points. The concussed sample included college-aged student-athletes (n = 132) evaluated before and after a concussion. Outcome measures included symptom severity scores, Automated Neuropsychological Assessment Metrics throughput scores, and Sensory Organization Test composite scores. Application of the reliable change parameters suggests that a small percentage of concussed participants were impaired on each measure. We identified a low sensitivity of the entire battery (all measures combined) of 50% but high specificity of 96%. Clinicians should be trained in understanding clinical concussion measures and should be aware of evidence suggesting the multifaceted battery is more sensitive than any single measure. Clinicians should be cautioned that sensitivity to balance and neurocognitive impairments was low for each individual measure. Applying the confidence intervals to our injured sample suggests that these measures do not adequately identify postconcussion impairments when used in isolation.

  20. Critical comparison of diffuse reflectance spectroscopy and colorimetry as dermatological diagnostic tools for acanthosis nigricans: a chemometric approach

    PubMed Central

    Devpura, Suneetha; Pattamadilok, Bensachee; Syed, Zain U.; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J.; Hamzavi, Iltefat; Lim, Henry W.; Naik, Ratna

    2011-01-01

    Quantification of skin changes due to acanthosis nigricans (AN), a disorder common among insulin-resistant diabetic and obese individuals, was investigated using two optical techniques: diffuse reflectance spectroscopy (DRS) and colorimetry. Measurements were obtained from AN lesions on the neck and two control sites of eight AN patients. A principal component/discriminant function analysis successfully differentiated between AN lesion and normal skin with 87.7% sensitivity and 94.8% specificity in DRS measurements and 97.2% sensitivity and 96.4% specificity in colorimetry measurements. PMID:21698027

  1. Sensitivity of Hyperdense Basilar Artery Sign on Non-Enhanced Computed Tomography

    PubMed Central

    Ernst, Marielle; Romero, Javier M.; Buhk, Jan-Hendrik; Cheng, Bastian; Herrmann, Jochen; Fiehler, Jens; Groth, Michael

    2015-01-01

    Purpose The hyperdense basilar artery sign (HBAS) is an indicator of vessel occlusion on non contrast-enhanced computer tomography (NECT) in acute stroke patients. Since basilar artery occlusion (BAO) is associated with a high mortality and morbidity, its early detection is of great clinical value. We sought to analyze the influence of density measurement as well as a normalized ratio of Hounsfield unit/hematocrit (HU/Hct) ratio on the detection of BAO on NECT in patients with suspected BAO. Materials and Methods 102 patients with clinically suspected BAO were examined with NECT followed immediately by Multidetector computed tomography Angiography. Two observers independently analyzed the images regarding the presence or absence of HBAS on NECT and performed HU measurements in the basilar artery. Receiver operating characteristic curve analysis was performed to determine the optimal density threshold for BAO using attenuation measurements or HU/Hct ratio. Results Sensitivity of visual detection of the HBAS on NECT was relatively low 81% (95%-CI, 54–95%) while specificity was high 91% (95%-CI, 82–96%). The highest sensitivity was achieved by the combination of visual assessment and additional quantitative attenuation measurements applying a cut-off value of 46.5 HU with 94% sensitivity and 81% specificity for BAO. A HU/Hct ratio >1.32 revealed sensitivity of 88% (95%-CI, 60–98%) and specificity of 84% (95%-CI, 74–90%). Conclusion In patients with clinically suspected acute BAO the combination of visual assessment and additional attenuation measurement with a cut-off value of 46.5 HU is a reliable approach with high sensitivity in the detection of BAO on NECT. PMID:26479718

  2. Reflex Cough and Disease Duration as Predictors of Swallowing Dysfunction in Parkinson's Disease.

    PubMed

    Troche, Michelle S; Schumann, Beate; Brandimore, Alexandra E; Okun, Michael S; Hegland, Karen W

    2016-12-01

    Patients with Parkinson's disease (PD) have progressive and pervasive disorders of airway protection. Recent work has highlighted the relationship between reflex and voluntary cough and swallowing safety. The goal of this study was to test the sensitivity and specificity of several airway protective and disease-specific factors for predicting swallowing safety outcomes in PD. Sixty-four participants (44 males) completed measures of voluntary and reflex cough, and swallowing safety. Clinical predictors included disease severity and duration, and cough airflow and sensitivity measures. ROC and Chi-square analyses identified predictors of swallowing safety (penetration-aspiration score) in PD. Disease duration significantly discriminated between patients with normal and abnormal swallowing safety (p = 0.027, sensitivity: 71 %, specificity: 55.4 %). Cough reflex sensitivity significantly discriminated between patients who penetrated above the level of the vocal folds and those with more severe penetration/aspiration (p = 0.021, sensitivity: 71.0 %, specificity 57.6 %). Urge-to-cough sensitivity (log-log linear slope) was the only variable which significantly discriminated between patients with penetration versus aspiration (p = 0.017, sensitivity: 85.7 %, specificity 73.2 %). It is important to identify the factors which influence airway protective outcomes in PD especially given that aspiration pneumonia is a leading cause of death. Results from this study highlight the ecological validity of reflex cough in the study of airway protection and this study further identifies important factors to consider in the screening of airway protective deficits in PD.

  3. Reliability, validity, sensitivity and specificity of Guajarati version of the Roland-Morris Disability Questionnaire.

    PubMed

    Nambi, S Gopal

    2013-01-01

    The most common instruments developed to assess the functional status of patients with Non specific low back pain is the Roland-Morris Disability Questionnaire (RMDQ). Clinical and epidemiological research related to low back pain in the Gujarati population would be facilitated by the availability of well-established outcome measures. To find the reliability, validity, sensitivity and specificity of the Gujarati version of the RMDQ for use in Non Specific Chronic low back pain. A reliability, validity, sensitivity and specificity study of Gujarati version of the Roland-Morris Disability Questionnaire (RMDQ). Thirty out patients with Non Specific Chronic low back pain were assessed by the RMDQ. Reliability is assessed by using internal consistency and the intra-class correlation coefficient (ICC). Internal construct validity is assessed by RASCH Analysis and external construct validity is assessed by association with pain and spinal movement. Clinical calculator was used to determine the sensitivity and specificity. Internal consistency of the RMDQ is found to be adequate (> 0.65) at both times, with high ICC's also at both time points. Internal construct validity of the scale is good, indicating a single underlying construct. Expected associations with pain and spinal movement confirm external construct validity. The Sensitivity and Specificity at cut off point of 0.5 was 80% and 84% with respectively positive predictive value (PPV) of 83.33% and negative predictive value (NPV) of 80.76%. The Questionnaire is at the ordinal level. The RMDQ is a one-dimensional, ordinal measure, which works well in the Gujarati population.

  4. Sensitivity to scale of willingness-to-pay within the context of menorrhagia.

    PubMed

    Sanghera, Sabina; Frew, Emma; Gupta, Janesh Kumar; Kai, Joe; Roberts, Tracy Elizabeth

    2017-04-01

    Willingness-to-pay (WTP) provides a broad assessment of well-being, capturing benefits beyond health. However, the validity of the approach has been questioned and the evidence relating to the sensitivity of WTP to changes in health status is mixed. Using menorrhagia (heavy menstrual bleeding) as a case study, this exploratory study assesses the sensitivity to scale of WTP to change in health status as measured by a condition-specific measure, MMAS, which includes both health and non-health benefits. The relationship between EQ-5D and change in health status is also assessed. Baseline EQ-5D and MMAS values were collected from women taking part in a randomized controlled trial for pharmaceutical treatment of menorrhagia. Following treatment, these measures were administered along with a WTP exercise. The relationship between the measures was assessed using Spearman's correlation analysis, and the sensitivity to scale of WTP was measured by identifying differences in WTP alongside differences in MMAS and EQ5D values. Our exploratory findings indicated that WTP, and not EQ-5D, was significantly positively correlated with change in MMAS, providing some evidence for convergent validity. These findings suggest that WTP is capturing the non-health benefits within the MMAS measure. Mean WTP also increased with percentage improvements in MMAS, suggesting sensitivity to scale. When compared to quality of life measured using the condition-specific MMAS measure, the convergent validity and sensitivity to scale of WTP is indicated. The findings suggest that WTP is more sensitive to change in MMAS, than with EQ-5D. © 2016 The Authors Health Expectations Published by John Wiley & Sons Ltd.

  5. Screening for Wilson disease in acute liver failure: a comparison of currently available diagnostic tests.

    PubMed

    Korman, Jessica D; Volenberg, Irene; Balko, Jody; Webster, Joe; Schiodt, Frank V; Squires, Robert H; Fontana, Robert J; Lee, William M; Schilsky, Michael L

    2008-10-01

    Acute liver failure (ALF) due to Wilson disease (WD) is invariably fatal without emergency liver transplantation. Therefore, rapid diagnosis of WD should aid prompt transplant listing. To identify the best method for diagnosis of ALF due to WD (ALF-WD), data and serum were collected from 140 ALF patients (16 with WD), 29 with other chronic liver diseases and 17 with treated chronic WD. Ceruloplasmin (Cp) was measured by both oxidase activity and nephelometry and serum copper levels by atomic absorption spectroscopy. In patients with ALF, a serum Cp <20 mg/dL by the oxidase method provided a diagnostic sensitivity of 21% and specificity of 84% while, by nephelometry, a sensitivity of 56% and specificity of 63%. Serum copper levels exceeded 200 microg/dL in all ALF-WD patients measured (13/16), but were also elevated in non-WD ALF. An alkaline phosphatase (AP) to total bilirubin (TB) ratio <4 yielded a sensitivity of 94%, specificity of 96%, and a likelihood ratio of 23 for diagnosing fulminant WD. In addition, an AST:ALT ratio >2.2 yielded a sensitivity of 94%, a specificity of 86%, and a likelihood ratio of 7 for diagnosing fulminant WD. Combining the tests provided a diagnostic sensitivity and specificity of 100%. Conventional WD testing utilizing serum ceruloplasmin and/or serum copper levels are less sensitive and specific in identifying patients with ALF-WD than other available tests. More readily available laboratory tests including alkaline phosphatase, bilirubin and serum aminotransferases by contrast provides the most rapid and accurate method for diagnosis of ALF due to WD.

  6. Diagnostic performance of optical coherence tomography ganglion cell--inner plexiform layer thickness measurements in early glaucoma.

    PubMed

    Mwanza, Jean-Claude; Budenz, Donald L; Godfrey, David G; Neelakantan, Arvind; Sayyad, Fouad E; Chang, Robert T; Lee, Richard K

    2014-04-01

    To evaluate the glaucoma diagnostic performance of ganglion cell inner-plexiform layer (GCIPL) parameters used individually and in combination with retinal nerve fiber layer (RNFL) or optic nerve head (ONH) parameters measured with Cirrus HD-OCT (Carl Zeiss Meditec, Inc, Dublin, CA). Prospective cross-sectional study. Fifty patients with early perimetric glaucoma and 49 age-matched healthy subjects. Three peripapillary RNFL and 3 macular GCIPL scans were obtained in 1 eye of each participant. A patient was considered glaucomatous if at least 2 of the 3 RNFL or GCIPL scans had the average or at least 1 sector measurement flagged at 1% to 5% or less than 1%. The diagnostic performance was determined for each GCIPL, RNFL, and ONH parameter as well as for binary or-logic and and-logic combinations of GCIPL with RNFL or ONH parameters. Sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR). Among GCIPL parameters, the minimum had the best diagnostic performance (sensitivity, 82.0%; specificity, 87.8%; PLR, 6.69; and NLR, 0.21). Inferior quadrant was the best RNFL parameter (sensitivity, 74%; specificity, 95.9%; PLR, 18.13; and NLR, 0.27), as was rim area (sensitivity, 68%; specificity, 98%; PLR, 33.3; and NLR, 0.33) among ONH parameters. The or-logic combination of minimum GCIPL and average RNFL provided the overall best diagnostic performance (sensitivity, 94%; specificity, 85.7%; PRL, 6.58; and NLR, 0.07) as compared with the best RNFL, best ONH, and best and-logic combination (minimum GCIPL and inferior quadrant RNFL; sensitivity, 64%; specificity, 100%; PLR, infinity; and NPR, 0.36). The binary or-logic combination of minimum GCIPL and average RNFL or rim area provides better diagnostic performances than those of and-logic combinations or best single GCIPL, RNFL, or ONH parameters. This finding may be clinically valuable for the diagnosis of early glaucoma. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Allergen exposure modifies the relation of sensitization to FENO levels in children at risk for allergy and asthma

    PubMed Central

    Sordillo, Joanne E; Webb, Tara; Kwan, Doris; Kamel, Jimmy; Hoffman, Elaine; Milton, Donald K; Gold, Diane R

    2011-01-01

    Background Studies on airway inflammation, measured as fraction exhaled nitric oxide (FENO), have focused on its relation to control of asthma, but the contribution of allergen exposure to elevation of FENO is unknown. Objective We evaluated (1) whether FENO was elevated in children with allergic sensitization or asthma; (2) whether specific allergen exposure increased FENO levels in sensitized, but not in unsensitized children; and (3) whether sedentary behavior increased FENO, independent of allergen exposures. Methods At age 12, in a birth cohort of children with parental history of allergy or asthma, we measured bed dust allergen (dust mite, cat, cockroach) by ELISA; specific allergic sensitization primarily by specific IgE ; and respiratory disease (current asthma, rhinitis, and wheeze) and hours of TV viewing/video game playing by questionnaire. Children performed spirometry maneuvers before and after bronchodilator responses, and had FENO measured using electrochemical detection methods (NIOX MINO). Results FENO was elevated in children with current asthma (32.2 ppb), wheeze (27.0 ppb), or rhinitis (23.2ppb) as compared to individuals without these respective symptoms/diagnoses (16.4 ppb to 16.6 ppb, p< 0.005 for all comparisons). Allergic sensitization to indoor allergens (cat, dog, dust mite) predicted higher levels of FENO, and explained one third of the variability of FENO. FENO levels were highest in children both sensitized and exposed to dust mite. Greater than 10 hours of weekday TV viewing was associated with a 0.64 log increase in FENO, after controlling indoor allergen exposure, BMI and allergic sensitization. Conclusion Allergen exposures and sedentary behavior (TV viewing/ video game playing), may increase airway inflammation, measured as FENO. PMID:21463890

  8. Connectome sensitivity or specificity: which is more important?

    PubMed

    Zalesky, Andrew; Fornito, Alex; Cocchi, Luca; Gollo, Leonardo L; van den Heuvel, Martijn P; Breakspear, Michael

    2016-11-15

    Connectomes with high sensitivity and high specificity are unattainable with current axonal fiber reconstruction methods, particularly at the macro-scale afforded by magnetic resonance imaging. Tensor-guided deterministic tractography yields sparse connectomes that are incomplete and contain false negatives (FNs), whereas probabilistic methods steered by crossing-fiber models yield dense connectomes, often with low specificity due to false positives (FPs). Densely reconstructed probabilistic connectomes are typically thresholded to improve specificity at the cost of a reduction in sensitivity. What is the optimal tradeoff between connectome sensitivity and specificity? We show empirically and theoretically that specificity is paramount. Our evaluations of the impact of FPs and FNs on empirical connectomes indicate that specificity is at least twice as important as sensitivity when estimating key properties of brain networks, including topological measures of network clustering, network efficiency and network modularity. Our asymptotic analysis of small-world networks with idealized modular structure reveals that as the number of nodes grows, specificity becomes exactly twice as important as sensitivity to the estimation of the clustering coefficient. For the estimation of network efficiency, the relative importance of specificity grows linearly with the number of nodes. The greater importance of specificity is due to FPs occurring more prevalently between network modules rather than within them. These spurious inter-modular connections have a dramatic impact on network topology. We argue that efforts to maximize the sensitivity of connectome reconstruction should be realigned with the need to map brain networks with high specificity. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Embedded measures of performance validity using verbal fluency tests in a clinical sample.

    PubMed

    Sugarman, Michael A; Axelrod, Bradley N

    2015-01-01

    The objective of this study was to determine to what extent verbal fluency measures can be used as performance validity indicators during neuropsychological evaluation. Participants were clinically referred for neuropsychological evaluation in an urban-based Veteran's Affairs hospital. Participants were placed into 2 groups based on their objectively evaluated effort on performance validity tests (PVTs). Individuals who exhibited credible performance (n = 431) failed 0 PVTs, and those with poor effort (n = 192) failed 2 or more PVTs. All participants completed the Controlled Oral Word Association Test (COWAT) and Animals verbal fluency measures. We evaluated how well verbal fluency scores could discriminate between the 2 groups. Raw scores and T scores for Animals discriminated between the credible performance and poor-effort groups with 90% specificity and greater than 40% sensitivity. COWAT scores had lower sensitivity for detecting poor effort. A combination of FAS and Animals scores into logistic regression models yielded acceptable group classification, with 90% specificity and greater than 44% sensitivity. Verbal fluency measures can yield adequate detection of poor effort during neuropsychological evaluation. We provide suggested cut points and logistic regression models for predicting the probability of poor effort in our clinical setting and offer suggested cutoff scores to optimize sensitivity and specificity.

  10. A Performance Comparison of Color Vision Tests for Military Screening.

    PubMed

    Walsh, David V; Robinson, James; Jurek, Gina M; Capó-Aponte, José E; Riggs, Daniel W; Temme, Leonard A

    2016-04-01

    Current color vision (CV) tests used for aviation screening in the U.S. Army only provide pass-fail results, and previous studies have shown variable sensitivity and specificity. The purpose of this study was to evaluate seven CV tests to determine an optimal CV test screener that potentially could be implemented by the U.S. Army. There were 133 subjects [65 Color Vision Deficits (CVD), 68 Color Vision Normal (CVN)] who performed all of the tests in one setting. CVD and CVN determination was initially assessed with the Oculus anomaloscope. Each test was administered monocularly and according to the test protocol. The main outcome measures were test sensitivity, specificity, and administration time (automated tests). Three of the four Pseudoisochromatic Plate (PIP) tests had a sensitivity/specificity > 0.90 OD/OS, whereas the FALANT tests had a sensitivity/specificity > 0.80 OD/OS. The Cone Contrast Test (CCT) demonstrated sensitivity/specificity > 0.90 OD/OS, whereas the Color Assessment and Diagnosis (CAD) test demonstrated sensitivity/specificity > 0.85 OD/OS. Comparison with the anomaloscope ("gold standard") revealed no significant difference of sensitivity and specificity OD/OS with the CCT, Dvorine PIP, and PIPC tests. Finally, the CCT administration time was significantly faster than the CAD test. The current U.S. Army CV screening tests demonstrated good sensitivity and specificity, as did the automated tests. In addition, some current PIP tests (Dvorine, PIPC), and the CCT performed no worse statistically than the anomaloscope with regard to sensitivity/specificity. The CCT letter presentation is randomized and results would not be confounded by potential memorization, or fading, of book plates.

  11. The sensitivity of benzene cluster cation chemical ionization mass spectrometry to select biogenic terpenes

    NASA Astrophysics Data System (ADS)

    Lavi, Avi; Vermeuel, Michael P.; Novak, Gordon A.; Bertram, Timothy H.

    2018-06-01

    Benzene cluster cations are a sensitive and selective reagent ion for chemical ionization of select biogenic volatile organic compounds. We have previously reported the sensitivity of a field deployable chemical ionization time-of-flight mass spectrometer (CI-ToFMS), using benzene cluster cation ion chemistry, for detection of dimethyl sulfide, isoprene and α-pinene. Here, we present laboratory measurements of the sensitivity of the same instrument to a series of terpenes, including isoprene, α-pinene, β-pinene, D-limonene, ocimene, β-myrcene, farnesene, α-humulene, β-caryophyllene, and isolongifolene at atmospherically relevant mixing ratios (< 100 pptv). In addition, we determine the dependence of CI-ToFMS sensitivity on the reagent ion neutral delivery concentration and water vapor concentration. We show that isoprene is primarily detected as an adduct (C5H8 ṡ C6H6+) with a sensitivity ranging between 4 and 10 ncps ppt-1, which depends strongly on the reagent ion precursor concentration, de-clustering voltages, and specific humidity (SH). Monoterpenes are detected primarily as the molecular ion (C10H16+) with an average sensitivity, across the five measured compounds, of 14 ± 3 ncps ppt-1 for SH between 7 and 14 g kg-1, typical of the boreal forest during summer. Sesquiterpenes are detected primarily as the molecular ion (C15H24+) with an average sensitivity, across the four measured compounds, of 9.6 ± 2.3 ncps ppt-1, that is also independent of specific humidity. Comparable sensitivities across broad classes of terpenes (e.g., monoterpenes and sesquiterpenes), coupled to the limited dependence on specific humidity, suggest that benzene cluster cation CI-ToFMS is suitable for field studies of biosphere-atmosphere interactions.

  12. Cost effectiveness analysis of screening for sight threatening diabetic eye disease

    PubMed Central

    James, Marilyn; Turner, David A; Broadbent, Deborah M; Vora, Jiten; Harding, Simon P

    2000-01-01

    Objective To measure the cost effectiveness of systematic photographic screening for sight threatening diabetic eye disease compared with existing practice. Design Cost effectiveness analysis Setting Liverpool. Subjects A target population of 5000 diabetic patients invited for screening. Main outcome measures Cost effectiveness (cost per true positive) of systematic and opportunistic programmes; incremental cost effectiveness of replacing opportunistic with systematic screening. Results Baseline prevalence of sight threatening eye disease was 14.1%. The cost effectiveness of the systematic programme was £209 (sensitivity 89%, specificity 86%, compliance 80%, annual cost £104 996) and of the opportunistic programme was £289 (combined sensitivity 63%, specificity 92%, compliance 78%, annual cost £99 981). The incremental cost effectiveness of completely replacing the opportunistic programme was £32. Absolute values of cost effectiveness were highly sensitive to varying prevalence, sensitivity and specificity, compliance, and programme size. Conclusion Replacing existing programmes with systematic screening for diabetic eye disease is justified. PMID:10856062

  13. Reliability of meat, fish, dairy, and egg intake over a 33-year interval in Adventist Health Study 2.

    PubMed

    Singh, Pramil N; Batech, Michael; Faed, Pegah; Jaceldo-Siegl, Karen; Martins, Marcia; Fraser, Gary E

    2014-01-01

    We studied Adventist Health Study 2 (AHS-2) cohort members to determine the reliability of long-term recall of adult dietary intake that occurred 33 years ago. Establishing the reliability of these measures supports studies of how dietary exposure across the life course affects risk of cancer and other noncommunicable disease outcomes. Among 1816 AHS-2 cohort members, we conducted a statistical comparison of long-term recall of meat, fish, dairy, and eggs at AHS-2 baseline with their report of current diet 33 years before AHS-2 baseline at an age of 30-60 years. Major findings are as follows: 1) a high correlation for frequency of red meat (R = 0.71), poultry (R = 0.67), and fish (R = 0.60); lower correlations for dairy (R = 0.19) and eggs (R = 0.28); 2) good concordance for dichotomous measures of red meat [sensitivity: 0.70; specificity: 0.92; positive predictive value (PPV): 0.91], poultry (sensitivity: 0.76; specificity: 0.87; PPV: 0.83), fish (sensitivity: 0.61; specificity: 0.93; PPV: 0.89), dairy (sensitivity: 0.95; specificity: 0.57; PPV: 0.99), and eggs (sensitivity: 0.95; specificity: 0.41; PPV: 0.96); negative predictive value for dairy and eggs was poor. Among older AHS-2 cohort members, we found good reliability of recall of red meat, poultry, and fish intake that occurred 33 years earlier.

  14. Fall risk screening protocol for older hearing clinic patients.

    PubMed

    Criter, Robin E; Honaker, Julie A

    2017-10-01

    The primary purposes of this study were (1) to describe measures that may contrast audiology patients who fall from those who do not fall and (2) to evaluate the clinical performance of measures that could be easily used for fall risk screening in a mainstream audiology hearing clinic. Cross-sectional study Study sample: Thirty-six community-dwelling audiology patient participants and 27 community-dwelling non-audiology patients over 60 years of age. The Hearing Handicap Inventory for the Elderly (HHIE) most accurately identified patients with a recent fall (sensitivity: 76.0%), while the Dizziness Handicap Inventory (DHI) most accurately identified patients without a recent fall (specificity: 90.9%). A combination of measures used in a protocol-including HHIE, DHI, number of medications, and the Timed Up and Go test-resulted in good, accurate identification of patients with or without a recent history of falls (92.0% sensitivity, 100% specificity). This study reports good sensitivity and excellent specificity for identifying patients with and without a recent history of falls when measures were combined into a screening protocol. Despite previously reported barriers, effective fall risk screenings may be performed in hearing clinic settings with measures often readily accessible to audiologists.

  15. Assessing the Sensitivity and Specificity of the MAYSI-2 for Detecting Trauma among Youth in Juvenile Detention

    ERIC Educational Resources Information Center

    Kerig, Patricia K.; Moeddel, Melissa Arnzen; Becker, Stephen P.

    2011-01-01

    This study investigated the sensitivity and specificity of the most widely used mental health screening instrument in juvenile detention, the Massachusetts Youth Screening Instrument (MAYSI-2), for detecting trauma and symptoms of posttraumatic stress disorder (PTSD) among detained youth. The MAYSI-2 scales measuring Substance Use,…

  16. Salivary calculus diagnosis with 3-dimensional cone-beam computed tomography.

    PubMed

    Dreiseidler, Timo; Ritter, Lutz; Rothamel, Daniel; Neugebauer, Jörg; Scheer, Martin; Mischkowski, Robert A

    2010-07-01

    The objective of this study was to evaluate cone-beam CT (CBCT) diagnoses of sialoliths in the major salivary glands. Twenty-nine CBCT images containing salivary calculi were retrospectively evaluated for image quality and artifact influence. Additionally, the reproducibility of calculus measurement and the differences between CBCT measurements and ultrasonography (US) and histomorphometry (HM) measurements were determined. Diagnostic sensitivity and specificity calculations were based on the observations of 3 masked clinicians, who reviewed a total of 58 CBCT volumes. Salivary calculi were sufficiently visualized in all patients. Metal artifacts were detected in images of 7 patients, and movement artifacts in 2. CBCT calculi measurements were highly reproducible, with mean differences of less than 350 microm. Mean CBCT measurements of calculi diameters differed from mean US measurements by approximately 500 microm and differed from mean HM measurements by approximately 1 mm. For calculus diagnoses, the mean sensitivity and specificity were both 98.85%. Although poor image qualities and artifacts can reduce diagnostic information, salivary calculi can be evaluated adequately with CBCT. CBCT measurements of calculi are highly reproducible and differ little from measurements made with US and HM. Diagnostic sensitivity and specificity levels with CBCT are as high as or higher than those obtained with other diagnostic methods. Because of its high diagnostic-information-to-radiation-dose ratio, CBCT is the preferable imaging modality for salivary calculus diagnosis. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  17. Measuring the impact of cataract surgery on generic and vision-specific quality of life.

    PubMed

    Groessl, Erik J; Liu, Lin; Sklar, Marisa; Tally, Steven R; Kaplan, Robert M; Ganiats, Theodore G

    2013-08-01

    Cataracts are the leading cause of blindness worldwide and cause visual impairment for millions of adults in the United States. We compared the sensitivity of a vision-specific health-related quality of life (HRQOL) measure to that of multiple generic measures of HRQOL before and at 2 time points after cataract surgery. Participants completed 1 vision-specific and 5 generic quality of life measures before cataract surgery, and again 1 and 6 months after surgery. Random effects modeling was used to measure changes over the three assessment points. The NEI-VFQ25 total score and all 11 subscales showed significant improvements during the first interval (baseline and 1 month). During the second interval (1-6 months post-surgery), significant improvements were observed on the total score and 5 of 11 NEI-VFQ25 subscales. There were significant increases in HRQOL during the first interval on some preference-based generic HRQOL measures, though changes during the second interval were mostly non-significant. None of the SF-36v2™ or SF6D scales changed significantly between any of the assessment periods. The NEI-VFQ25 was sensitive to changes in vision-specific domains of QOL. Some preference-based generic HRQOL measures were also sensitive to change and showed convergence with the NEI-VFQ25, but the effects were small. The SF-36v2™ and SF-6D did not change in a similar manner, possibly reflecting a lack of vision-related content. Studies seeking to document both the vision-specific and generic HRQOL improvements of cataract surgery should consider these results when selecting measures.

  18. Biosensors based on Si3N4 asymmetric Mach-Zehnder interferometers

    NASA Astrophysics Data System (ADS)

    Chalyan, Tatevik; Pasquardini, Laura; Falke, Floris; Zanetti, Manuela; Guider, Romain; Gandolfi, Davide; Schreuder, Eric; Pederzolli, Cecilia; Heideman, René G.; Pavesi, Lorenzo

    2016-04-01

    In this work, we present a study on photonic biosensors based on Si3N4 asymmetric Mach-Zehnder Interferometers (aMZI) for Aflatoxin M1 (AFM1) detection. AFM1 is an hepatotoxic and a carcinogenic toxin present in milk. The biosensor is based on an array of four Si3N4 aMZI that are optimized for 850nm wavelength. We measure the bulk Sensitivity (S) and the Limit of Detection (LOD) of our devices. In the array, three devices are exposed and have very similar sensitivities. The fourth aMZI, which is covered by SiO2, is used as an internal reference for laser (a VCSEL) and temperature fluctuations. We measured a phase sensitivity of 14300+/-400 rad/RIU. To characterize the LOD of the sensors, we measure the uncertainty of the experimental readout system. From the measurements on three aMZI, we observe the same value of LOD, which is ≍ 4.5×10-7 RIU. After the sensor characterization on homogeneous sensing, we test the surface sensing performances by flowing specific Aflatoxin M1 and non-specific Ochratoxin in 50 mM MES pH 6.6 buffer on the top of the sensors functionalized with Antigen-Recognising Fragments (Fab'). The difference between specific and non-specific signals shows the specificity of our sensors. A moderate regeneration of the sensors is obtained by using glycine solution.

  19. A Two-Domain Self-Report Measure of Periodontal Disease Has Good Accuracy for Periodontitis Screening in Dental School Outpatients.

    PubMed

    Chatzopoulos, Georgios S; Tsalikis, Lazaros; Konstantinidis, Antonios; Kotsakis, Georgios A

    2016-10-01

    The assessment of periodontitis and treatment needs is primarily based on clinical and radiographic examinations. Albeit effective in predicting treatment needs, these examinations are costly, time-consuming, and impractical for assessing population-level needs. The purpose of the present study is to evaluate a two-domain self-report questionnaire for rapid periodontitis screening. Six hundred white adult individuals, dentate or partially dentate and seeking dental therapy at a university clinic, underwent oral examination utilizing the full-mouth Community Periodontal Index of Treatment Needs (CPITN). To assess predictive value of self-reported periodontal measures (SRPMs) for periodontitis screening, four questions were formulated. Two questions aimed to assess "dentist-diagnosed periodontal disease" and two inquired about "self-assessed periodontitis." Multiple logistic regression models were used to construct receiver-operating characteristic curves, and predictor selection was performed via a forward stepwise selection process. Five hundred thirty-five volunteers with a mean age of 50.1 years elected to respond to SRPMs via telephone interview. After oral examination, 17.8% of participants were assessed as having CPITN = 4, representing compromised periodontal status. Sensitivity and specificity for correctly classifying compromised periodontal status ranged from 5.3% to 72.6%, and 87.8% to 99.5% for individual SRPMs. Sensitivity and specificity were increased when combining a measure of self-assessed periodontal disease and a measure of dentist-diagnosed disease as predictors. Addition of age and sex maximized sensitivity/specificity at 82.1%/82.2%. Diabetic status, smoking, and body mass index did not enhance the prediction. A two-domain self-report measure combining two self-report items with age and sex has good sensitivity and specificity for periodontitis screening in a white, university-based population. The proposed self-report measure can be valuable for periodontitis screening in resource-limited settings where gold standard clinical examination may not be pragmatic. Further validation studies are required to assess whether findings from this study are context-specific.

  20. [The diagnostic value of ultrasonic elastography and ultrasonography comprehensive score in cervical lesions].

    PubMed

    Lu, R; Xiao, Y

    2017-07-18

    Objective: To evaluate the clinical value of ultrasonic elastography and ultrasonography comprehensive scoring method in the diagnosis of cervical lesions. Methods: A total of 116 patients were selected from the Department of Gynecology of the first hospital affiliated with Central South University from March 2014 to September 2015.All of the lesions were preoperatively examined by Doppler Ultrasound and elastography.The elasticity score was determined by a 5-point scoring method. Calculation of the strain ratio was based on a comparison of the average strain measured in the lesion with the adjacent tissue of the same depth, size, and shape.All these ultrasonic parameters were quantified, added, and arrived at ultrasonography comprehensive scores.To use surgical pathology as the gold standard, the sensitivity, specificity, accuracy of Doppler Ultrasound, elasticity score and strain ratio methods and ultrasonography comprehensive scoring method were comparatively analyzed. Results: (1) The sensitivity, specificity, and accuracy of Doppler Ultrasound in diagnosing cervical lesions were 82.89% (63/76), 85.0% (34/40), and 83.62% (97/116), respectively.(2) The sensitivity, specificity, and accuracy of the elasticity score method were 77.63% (59/76), 82.5% (33/40), and 79.31% (92/116), respectively; the sensitivity, specificity, and accuracy of the strain ratio measure method were 84.21% (64/76), 87.5% (35/40), and 85.34% (99/116), respectively.(3) The sensitivity, specificity, and accuracy of ultrasonography comprehensive scoring method were 90.79% (69/76), 92.5% (37/40), and 91.38% (106/116), respectively. Conclusion: (1) It was obvious that ultrasonic elastography had certain diagnostic value in cervical lesions. Strain ratio measurement can be more objective than elasticity score method.(2) The combined application of ultrasonography comprehensive scoring method, ultrasonic elastography and conventional sonography was more accurate than single parameter.

  1. The product of triglycerides and glucose, a simple measure of insulin sensitivity. Comparison with the euglycemic-hyperinsulinemic clamp.

    PubMed

    Guerrero-Romero, Fernando; Simental-Mendía, Luis E; González-Ortiz, Manuel; Martínez-Abundis, Esperanza; Ramos-Zavala, María G; Hernández-González, Sandra O; Jacques-Camarena, Omar; Rodríguez-Morán, Martha

    2010-07-01

    To meet the worldwide challenge of emerging diabetes, accessible and inexpensive tests to identify insulin resistance are needed. To evaluate the sensitivity and specificity of the product of fasting, we compared the triglycerides and glucose (TyG) index, a simple measure of insulin resistance, with the euglycemic-hyperinsulinemic clamp test. We conducted a cross-sectional study of the general population and outpatients of the Internal Medicine Department at the Medical Unit of High Specialty of the Specialty Hospital at the West National Medical Center in Guadalajara, Mexico. Eleven nonobese healthy subjects, 34 obese normal glucose tolerance individuals, 22 subjects with prediabetes, and 32 diabetic patients participated in the study. We performed a euglycemic-hyperinsulinemic clamp test. Sensitivity and specificity of the TyG index [Ln(fasting triglycerides) (mg/dl) x fasting glucose (mg/dl)/2] were measured, as well as the area under the curve of the receiver operating characteristic scatter plot and the correlation between the TyG index and the total glucose metabolism (M) rates. Pearson's correlation coefficient between the TyG index and M rates was -0.681 (P < 0.005). Correlation between the TyG index and M rates was similar between men (-0.740) and women (-0.730), nonobese (-0.705) and obese (-0.710), and nondiabetic (-0.670) and diabetic (-0.690) individuals. The best value of the TyG index for diagnosis of insulin resistance was 4.68, which showed the highest sensitivity (96.5%) and specificity (85.0%; area under the curve + 0.858). The TyG index has high sensitivity and specificity, suggesting that it could be useful for identification of subjects with decreased insulin sensitivity.

  2. Comparison of methods used to diagnose generalized inflammatory disease in manatees (Trichechus manatus latirostris)

    USGS Publications Warehouse

    Harr, K.E.; Harvey, J.W.; Bonde, R.K.; Murphy, D.; Lowe, Mark; Menchaca, M.; Haubold, E.M.; Francis-Floyd, R.

    2006-01-01

    Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as “cold stress syndrome” and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha1 acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10–50 μg/ml with an equivocal interval of 51–70 μg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7–1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4–2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100–400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.

  3. Comparison of methods used to diagnose generalized inflammatory disease in manatees (Trichechus manatus latirostris).

    PubMed

    Harr, Kendal; Harvey, John; Bonde, Robert; Murphy, David; Lowe, Mark; Menchaca, Maya; Haubold, Elsa; Francis-Floyd, Ruth

    2006-06-01

    Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as "cold stress syndrome" and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha, acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10-50 microg/ml with an equivocal interval of 51-70 microg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7-1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4-2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100-400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.

  4. Diagnosis of sleep apnea in patients with stable chronic heart failure using a portable sleep test diagnostic device.

    PubMed

    Araújo, Inês; Marques, Filipa; André, Sandra; Araújo, Manuel; Marques, Sara; Ferreira, Rita; Moniz, Patrícia; Proença, Margarida; Borrego, Pedro; Fonseca, Cândida

    2018-01-17

    ApneaLink is a portable device for the screening of sleep apnea, a prevalent and underdiagnosed comorbidity in heart failure patients. A prospective cross-sectional study in patients with chronic heart failure was carried out to assess the sensitivity and specificity of apnea-hypopnea index (AHI) measurements using ApneaLink against the standard polysomnography test. Adult patients with a prior hospitalization in an acute heart failure hospital unit were recruited for the study. All participants were tested for sleep apnea using ApneaLink and polysomnography simultaneously during an overnight stay at a sleep laboratory. Global sleep apnea was evaluated according to the AHI, which was analyzed and compared. Subpopulation comparison based on ejection fraction was not realized due to population size. Thirty-five patients with stable chronic heart failure completed the study (mean age 70.9 ± 10.5 years and body mass index 30.0 ± 4.7 kg/m 2 ). Two patients were excluded due to insufficient study duration. ApneaLink had a sensitivity greater than 80% for all AHI measurements, and a specificity greater than 80% for all AHI measurements, except for AHI ≥ 5 events/h (61.5%). The results showed higher sensitivities and specificities at AHI values of ≥ 10 events/h (sensitivity 81.3% and specificity 84.2%) and ≥ 15 events/h (sensitivity 83.3% and specificity 91.3%). Correlation analysis showed that AHI measurements using ApneaLink and polysomnography had a strong and significant correlation (r = 0.794; P < 0.001). Our results suggest that ApneaLink could be used in clinical practice to identify heart failure patients with high (AHI ≥ 15 events/h) and low (AHI < 5 events/h) probability of having sleep apnea, sparing the need for a diagnostic polysomnography and thus potentially impacting prognosis by providing a more cost-effective and timely diagnosis of this non-cardiac comorbidity.

  5. Social reward and social punishment sensitivity in relation to dietary restraint and binge/purge symptoms.

    PubMed

    Fussner, Lauren M; Luebbe, Aaron M; Smith, April R

    2018-08-01

    Disordered eating symptoms are associated with disrupted sensitivity to reward and punishment, broadly assessed. However, it is unknown how eating pathology is related to sensitivity to social reward and social punishment specifically. Drawing on Reinforcement Sensitivity Theory, the current study utilized a multi-method design to test whether disordered eating symptoms, specifically dietary restraint (DR) and binge/purge (BP), were similarly or uniquely related to sensitivity to social punishment and social reward. Female university students (N = 110, M = 18.66, SD = 0.89) completed self-report measures and a novel behavioral task measuring willingness to work for or to avoid social feedback. DR and BP symptoms were related to increased self-reported and behavioral sensitivity to social punishment, yet only when symptoms were tested in isolation. DR was associated with increased sensitivity to social reward across self-report and behavioral paradigms. BP symptoms were uniquely and positively related to self-reported sensitivity to social reward, but decreased behavioral sensitivity to social reward. Findings suggest that sensitivity to punishment may be a common factor related to DR and BP, whereas sensitivity to social reward may be a key factor differentiating disordered eating symptoms. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Subject-specific finite element modelling of the human foot complex during walking: sensitivity analysis of material properties, boundary and loading conditions.

    PubMed

    Akrami, Mohammad; Qian, Zhihui; Zou, Zhemin; Howard, David; Nester, Chris J; Ren, Lei

    2018-04-01

    The objective of this study was to develop and validate a subject-specific framework for modelling the human foot. This was achieved by integrating medical image-based finite element modelling, individualised multi-body musculoskeletal modelling and 3D gait measurements. A 3D ankle-foot finite element model comprising all major foot structures was constructed based on MRI of one individual. A multi-body musculoskeletal model and 3D gait measurements for the same subject were used to define loading and boundary conditions. Sensitivity analyses were used to investigate the effects of key modelling parameters on model predictions. Prediction errors of average and peak plantar pressures were below 10% in all ten plantar regions at five key gait events with only one exception (lateral heel, in early stance, error of 14.44%). The sensitivity analyses results suggest that predictions of peak plantar pressures are moderately sensitive to material properties, ground reaction forces and muscle forces, and significantly sensitive to foot orientation. The maximum region-specific percentage change ratios (peak stress percentage change over parameter percentage change) were 1.935-2.258 for ground reaction forces, 1.528-2.727 for plantar flexor muscles and 4.84-11.37 for foot orientations. This strongly suggests that loading and boundary conditions need to be very carefully defined based on personalised measurement data.

  7. Plasma glycosylphosphatidylinositol-specific phospholipase D predicts the change in insulin sensitivity in response to a low fat but not a low carbohydrate diet in obese women

    PubMed Central

    Gray, Dona L.; O’Brien, Kevin D.; D’Alessio, David A.; Brehm, Bonnie J.; Deeg, Mark A.

    2013-01-01

    Context Although circulating glycosylphosphatidylinositol-specific phospholipase D, a minor high density lipoprotein-associated protein, is elevated in patients with insulin resistance or high triglycerides, no information is available on the effect of weight loss or changes in insulin sensitivity on circulating glycosylphosphatidylinositol-specific phospholipase D levels. Objective Determine the effect of weight loss and changes in insulin sensitivity on plasma glycosylphosphatidylinositol-specific phospholipase D levels. Participants Forty two non-diabetic obese women. Intervention Three month dietary intervention randomizing patients to a low fat or a low carbohydrate diet. Main outcome measures Plasma glycosylphosphatidylinositol-specific phospholipase D levels and insulin sensitivity as estimated by the homeostasis model assessment. Results The very low carbohydrate diet group lost more weight after 3 months (−7.6 ± 3.2 vs. −4.2 ± 3.5 kg, P < 0.01) although the decrease in insulin resistance was similar between groups. Weight loss with either diet did not alter plasma glycosylphosphatidylinositol-specific phospholipase D levels. However, baseline glycosylphosphatidylinositol-specific phospholipase D levels correlated with the change in insulin sensitivity in response to the low fat diet while baseline insulin sensitivity correlated the change in insulin sensitivity in response to the low carbohydrate diet. Conclusions Plasma GPI-PLD may serve as a clinical tool to determine the effect of a low fat diet on insulin sensitivity. PMID:18328347

  8. Efficiency measures and output specification : the case of European railways

    DOT National Transportation Integrated Search

    2000-12-01

    This study analyzes the sensitivity of the efficiency indicators of a sample of European railway companies to different alternatives in output specification. The results vary according to the specification selected. Investigating the causes of these ...

  9. Some More Sensitive Measures of Sensitivity and Response Bias

    NASA Technical Reports Server (NTRS)

    Balakrishnan, J. D.

    1998-01-01

    In this article, the author proposes a new pair of sensitivity and response bias indices and compares them to other measures currently available, including d' and Beta of signal detection theory. Unlike d' and Beta, these new performance measures do not depend on specific distributional assumptions or assumptions about the transformation from stimulus information to a discrimination judgment with simulated and empirical data, the new sensitivity index is shown to be more accurate than d' and 16 other indices when these measures are used to compare the sensitivity levels of 2 experimental conditions. Results from a perceptual discrimination experiment demonstrate the feasibility of the new distribution-free bias index and suggest that biases of the type defined within the signal detection theory framework (i.e., the placement of a decision criterion) do not exist, even under an asymmetric payoff manipulation.

  10. Peripheral DXA measurement around ankle joint to diagnose osteoporosis as assessed by central DXA measurement.

    PubMed

    Sung, Ki Hyuk; Choi, Young; Cho, Gyeong Hee; Chung, Chin Youb; Park, Moon Seok; Lee, Kyoung Min

    2018-02-05

    This study evaluated the correlation between central and peripheral bone mineral density (BMD) of the ankle joint, using dual-energy X-ray absorptiometry (DXA). We also investigated whether peripheral ankle BMD could be used to identify individuals who were diagnosed with osteoporosis, using central DXA. We recruited 134 volunteers aged 20-90 years who agreed to participate in this study. Central BMD of the lumbar spine and left femur, and peripheral BMD of the medial malleolus, distal tibia, lateral malleolus, and talus were measured with DXA. Among the peripheral sites of the ankle, the highest and lowest BMD were observed in the talus and lateral malleolus, respectively. All peripheral DXA measurements of the ankle joint were significantly correlated with central DXA measurements. There was a good correlation (r: 0.656-0.725) between peripheral and central BMD for the older age group (> 50 years), but fair-to-good correlation (r: 0.263-0.654) for the younger age group (< 50 years). The cut-off values for peripheral BMD of the ankle joint between osteoporosis and non-osteoporosis were 0.548 g/cm 2 (sensitivity, 89.0%; specificity, 69.0%) for the medial malleolus, 0.626 g/cm 2 (sensitivity, 83.3%; specificity, 82.8%) for the distal tibia, 0.47 g/cm 2 (sensitivity, 100.0%; specificity, 65.5%) for the lateral malleolus, and 0.973 g/cm 2 (sensitivity, 72.2%; specificity, 83.6%) for the talus (p < 0.001). This study showed good correlation between peripheral BMD around ankle joint and central BMD for older age group. Further study is required to use the ankle DXA as a valid clinical tool for the diagnosis of osteoporosis and fracture risk assessment.

  11. Enhanced sensitivity in detection of antiviral antibody responses using biotinylation of foot-and-mouth disease virus (FMDV) capsids

    USDA-ARS?s Scientific Manuscript database

    Analysis of the immune response to infection of livestock by foot-and-mouth disease virus (FMDV) is most often reported as the serum antibody response to the virus. While measurement of neutralizing antibody has been sensitive and specific, measurements of the quality of the antibody response are le...

  12. Discrimination of skin sensitizers from non-sensitizers by interleukin-1α and interleukin-6 production on cultured human keratinocytes.

    PubMed

    Jung, Daun; Che, Jeong-Hwan; Lim, Kyung-Min; Chun, Young-Jin; Heo, Yong; Seok, Seung Hyeok

    2016-09-01

    In vitro testing methods for classifying sensitizers could be valuable alternatives to in vivo sensitization testing using animal models, such as the murine local lymph node assay (LLNA) and the guinea pig maximization test (GMT), but there remains a need for in vitro methods that are more accurate and simpler to distinguish skin sensitizers from non-sensitizers. Thus, the aim of our study was to establish an in vitro assay as a screening tool for detecting skin sensitizers using the human keratinocyte cell line, HaCaT. HaCaT cells were exposed to 16 relevant skin sensitizers and 6 skin non-sensitizers. The highest dose used was the dose causing 75% cell viability (CV75) that we determined by an MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay. The levels of extracellular production of interleukin-1α (IL-1α) and IL-6 were measured. The sensitivity of IL-1α was 63%, specificity was 83% and accuracy was 68%. In the case of IL-6, sensitivity: 69%, specificity: 83% and accuracy: 73%. Thus, this study suggests that measuring extracellular production of pro-inflammatory cytokines IL-1α and IL-6 by human HaCaT cells may potentially classify skin sensitizers from non-sensitizers. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Factors affecting the sensitivity and specificity of the Heidelberg Retina Tomograph parameters to glaucomatous progression in disc photographs.

    PubMed

    Saarela, Ville; Falck, Aura; Airaksinen, P Juhani; Tuulonen, Anja

    2012-03-01

    To evaluate the factors affecting the sensitivity and specificity of the stereometric optic nerve head (ONH) parameters of the Heidelberg Retina Tomograph (HRT) to glaucomatous progression in stereoscopic ONH photographs. The factors affecting the sensitivity and specificity of the vertical cup : disc ratio, the cup : disc area ratio, the cup volume, the rim area and a linear discriminant function to progression were analysed. These parameters were the best indicators of progression in a retrospective study of 476 eyes. The reference standard for progression was the masked evaluation of stereoscopic ONH photographs. The factors having the most significant effect on the sensitivity and specificity of the stereometric ONH parameters were the reference height difference and the mean topography standard deviation (TSD), indicating image quality. Also, the change in the TSD and age showed consistent, but variably significant, influence on all parameters tested. The sensitivity and specificity improved when there was little change in the reference height, the image quality was good and stable, and the patients were younger. The sensitivity and specificity of the vertical cup : disc ratio was improved by a large disc area and high baseline cup : disc area ratio. The rim area showed a better sensitivity and specificity for progression with a small disc area and low baseline cup : disc area ratio. The factors affecting the sensitivity and specificity of the stereometric ONH parameters to glaucomatous progression in disc photographs are essentially the same as those affecting the measurement variability of the HRT. © 2010 The Authors. Acta Ophthalmologica © 2010 Acta Ophthalmologica Scandinavica Foundation.

  14. Reliability of Meat, Fish, Dairy, and Egg Intake Over a 33-Year Interval in Adventist Health Study 2

    PubMed Central

    Singh, Pramil N.; Batech, Michael; Faed, Pegah; Jaceldo-Siegl, Karen; Martins, Marcia; Fraser, Gary E.

    2015-01-01

    We studied Adventist Health Study 2 (AHS-2) cohort members to determine the reliability of long-term recall of adult dietary intake that occurred 33 years ago. Establishing the reliability of these measures supports studies of how dietary exposure across the life course affects risk of cancer and other noncommunicable disease outcomes. Among 1816 AHS-2 cohort members, we conducted a statistical comparison of long-term recall of meat, fish, dairy, and eggs at AHS-2 baseline with their report of current diet 33 years before AHS-2 baseline at an age of 30–60 years. Major findings are as follows: 1) a high correlation for frequency of red meat (R = 0.71), poultry (R = 0.67), and fish (R = 0.60); lower correlations for dairy (R = 0.19) and eggs (R = 0.28); 2) good concordance for dichotomous measures of red meat [sensitivity: 0.70; specificity: 0.92; positive predictive value (PPV): 0.91], poultry (sensitivity: 0.76; specificity: 0.87; PPV: 0.83), fish (sensitivity: 0.61; specificity: 0.93; PPV: 0.89), dairy (sensitivity: 0.95; specificity: 0.57; PPV: 0.99), and eggs (sensitivity: 0.95; specificity: 0.41; PPV: 0.96); negative predictive value for dairy and eggs was poor. Among older AHS-2 cohort members, we found good reliability of recall of red meat, poultry, and fish intake that occurred 33 years earlier. PMID:25298211

  15. Diagnostic value of the basophil activation test in evaluating Hymenoptera venom sensitization.

    PubMed

    Peternelj, Andreja; Silar, Mira; Bajrovic, Nissera; Adamic, Katja; Music, Ema; Kosnik, Mitja; Korosec, Peter

    2009-01-01

    Diagnosis of allergy to Hymenoptera venom is usually confirmed with skin testing and measurement of specific serum IgE antibody, tests which are sometimes inconclusive. In these cases, additional in vitro tests are necessary. The aim of this study was to show the applicability of the basophil activation test in detecting sensitization to Hymenoptera venom and to compare the test sensitivity and clinical positive-predictive value with skin prick tests and measurement of allergen-specific serum IgE. This prospective study was conducted between June 2004 and December 2007 and included a large group of 204 patients. All patients had a history of at least one systemic allergic reaction of Müller grades II-IV after a Hymenoptera sting. We compared results of the basophil activation test, specific serum IgE and skin prick tests with patients' clinical history and data on culprit insects. The overall clinical sensitivities of the basophil activation test, specific serum IgE and skin prick tests were 90%, 76% and 64%, respectively; the clinical positive-predictive values of the three tests were 79%, 73% and 78% for bee venom, 86%, 59% and 43% for wasp venom; and 84%, 77% and 22% for both venoms. Our results revealed a higher clinical sensitivity and comparable or better clinical positive-predictive value of basophil activation tests than skin prick tests and allergen-specific serum IgE in the detection of allergy to Hymenoptera venom.

  16. Cognitive Screening in Brain Tumors: Short but Sensitive Enough?

    PubMed Central

    Robinson, Gail A.; Biggs, Vivien; Walker, David G.

    2015-01-01

    Cognitive deficits in brain tumors are generally thought to be relatively mild and non-specific, although recent evidence challenges this notion. One possibility is that cognitive screening tools are being used to assess cognitive functions but their sensitivity to detect cognitive impairment may be limited. For improved sensitivity to recognize mild and/or focal cognitive deficits in brain tumors, neuropsychological evaluation tailored to detect specific impairments has been thought crucial. This study investigates the sensitivity of a cognitive screening tool, the Montreal Cognitive Assessment (MoCA), compared to a brief but tailored cognitive assessment (CA) for identifying cognitive deficits in an unselected primary brain tumor sample (i.e., low/high-grade gliomas, meningiomas). Performance is compared on broad measures of impairment: (a) number of patients impaired on the global screening measure or in any cognitive domain; and (b) number of cognitive domains impaired and specific analyses of MoCA-Intact and MoCA-Impaired patients on specific cognitive tests. The MoCA-Impaired group obtained lower naming and word fluency scores than the MoCA-Intact group, but otherwise performed comparably on cognitive tests. Overall, based on our results from patients with brain tumor, the MoCA has extremely poor sensitivity for detecting cognitive impairments and a brief but tailored CA is necessary. These findings will be discussed in relation to broader issues for clinical management and planning, as well as specific considerations for neuropsychological assessment of brain tumor patients. PMID:25815273

  17. Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis.

    PubMed

    Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa

    2017-01-17

    Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.

  18. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review.

    PubMed

    Irving, Greg; Holden, John; Stevens, Richard; McManus, Richard J

    2016-11-03

    To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement. BP measurement with a correctly fitting upper arm cuff is sufficiently sensitive and specific to diagnose hypertension in patients with obesity with a large upper arm circumference. If a correctly fitting upper arm cuff cannot be applied, an incorrectly fitting standard size cuff should not be used and BP measurement at the wrist should be considered. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review

    PubMed Central

    Holden, John

    2016-01-01

    Objective To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. Design Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. Data sources MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. Eligibility criteria Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. Results 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement. Conclusions BP measurement with a correctly fitting upper arm cuff is sufficiently sensitive and specific to diagnose hypertension in patients with obesity with a large upper arm circumference. If a correctly fitting upper arm cuff cannot be applied, an incorrectly fitting standard size cuff should not be used and BP measurement at the wrist should be considered. PMID:27810973

  20. A method for identifying color vision deficiency malingering.

    PubMed

    Pouw, Andrew; Karanjia, Rustum; Sadun, Alfredo

    2017-03-01

    To propose a new test to identify color vision deficiency malingering. An online survey was distributed to 130 truly color vision deficient participants and 160 participants willing to simulate color vision deficiency. The survey contained three sets of six color-adjusted versions of the standard Ishihara color plates each, as well as one set of six control plates. The plates that best discriminated both participant groups were selected for a "balanced" test emphasizing both sensitivity and specificity. A "specific" test that prioritized high specificity was also created by selecting from these plates. Statistical measures of the test (sensitivity, specificity, and Youden index) were assessed at each possible cut-off threshold, and a receiver operating characteristic (ROC) function with its area under the curve (AUC) charted. The redshift plate set was identified as having the highest difference of means between groups (-58%, CI: -64 to -52%), as well as the widest gap between group modes. Statistical measures of the "balanced" test show an optimal cut-off of at least two incorrectly identified plates to suggest malingering (Youden index: 0.773, sensitivity: 83.3%, specificity: 94.0%, AUC of ROC 0.918). The "specific" test was able to identify color vision deficiency simulators with a specificity of 100% when using a cut-off of at least two incorrectly identified plates (Youden index 0.599, sensitivity 59.9%, specificity 100%, AUC of ROC 0.881). Our proposed test for identifying color vision deficiency malingering demonstrates a high degree of reliability with AUCs of 0.918 and 0.881 for the "balanced" and "specific" tests, respectively. A cut-off threshold of at least two missed plates on the "specific" test was able to identify color vision deficiency simulators with 100% specificity.

  1. Population-based assessment of sensitivity and specificity of a pinhole for detection of significant refractive errors in the community.

    PubMed

    Marmamula, Srinivas; Keeffe, Jill E; Narsaiah, Saggam; Khanna, Rohit C; Rao, Gullapalli N

    2014-11-01

    Measurements of refractive errors through subjective or automated refraction are not always possible in rapid assessment studies and community vision screening programs; however, measurements of vision with habitual correction and with a pinhole can easily be made. Although improvements in vision with a pinhole are assumed to mean that a refractive error is present, no studies have investigated the magnitude of improvement in vision with pinhole that is predictive of refractive error. The aim was to measure the sensitivity and specificity of 'vision improvement with pinhole' in predicting the presence of refractive error in a community setting. Vision and vision with pinhole were measured using a logMAR chart for 488 of 582 individuals aged 15 to 50 years. Refractive errors were measured using non-cycloplegic autorefraction and subjective refraction. The presence of refractive error was defined using spherical equivalent refraction (SER) at two levels: SER greater than ± 0.50 D sphere (DS) and SER greater than ±1.00 DS. Three definitions for significant improvement in vision with a pinhole were used: 1. Presenting vision less than 6/12 and improving to 6/12 or better, 2. Improvement in vision of more than one logMAR line and 3. Improvement in vision of more than two logMAR lines. For refractive error defined as spherical equivalent refraction greater than ± 0.50 DS, the sensitivities and specificities for the pinhole test predicting the presence of refractive error were 83.9 per cent (95% CI: 74.5 to 90.9) and 98.8 per cent (95% CI: 97.1 to 99.6), respectively for definition 1. Definition 2 had a sensitivity 89.7 per cent (95% CI: 81.3 to 95.2) and specificity 88.0 per cent (95% CI: 4.4 to 91.0). Definition 3 had a sensitivity of 75.9 per cent (95% CI: 65.5 to 84.4) and specificity of 97.8 per cent (95% CI: 95.8 to 99.0). Similar results were found with spherical equivalent refraction greater than ±1.00 DS, when tested against the three pinhole-based definitions. Refractive error definitions based on improvement in vision with the pinhole shows good sensitivity and specificity at predicting the presence of significant refractive errors. These definitions can be used in rapid assessment surveys and community-based vision screenings. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.

  2. Sensitivity and specificity of memory and naming tests for identifying left temporal-lobe epilepsy.

    PubMed

    Umfleet, Laura Glass; Janecek, Julie K; Quasney, Erin; Sabsevitz, David S; Ryan, Joseph J; Binder, Jeffrey R; Swanson, Sara J

    2015-01-01

    The sensitivity and specificity of the Selective Reminding Test (SRT) Delayed Recall, Wechsler Memory Scale (WMS) Logical Memory, the Boston Naming Test (BNT), and two nonverbal memory measures for detecting lateralized dysfunction in association with side of seizure focus was examined in a sample of 143 patients with left or right temporal-lobe epilepsy (TLE). Scores on the SRT and BNT were statistically significantly lower in the left TLE group compared with the right TLE group, whereas no group differences emerged on the Logical Memory subtest. No significant group differences were found with nonverbal memory measures. When the SRT and BNT were both entered as predictors in a logistic regression, the BNT, although significant, added minimal value to the model beyond the variance accounted for by the SRT Delayed Recall. Both variables emerged as significant predictors of side of seizure focus when entered into separate regressions. Sensitivity and specificity of the SRT and BNT ranged from 56% to 65%. The WMS Logical Memory and nonverbal memory measures were not significant predictors of the side of seizure focus.

  3. Sensitivity and specificity of criteria for classifying body mass index in adolescents.

    PubMed

    Farias Júnior, José Cazuza de; Konrad, Lisandra Maria; Rabacow, Fabiana Maluf; Grup, Susane; Araújo, Valbério Candido

    2009-02-01

    To estimate the prevalence of overweight among adolescents using different body mass index (BMI) classification criteria, and to determine sensitivity and specificity values for these criteria. Weight, height, and tricipital and subscapular skinfolds in 934 adolescents (462 males and 472 females) aged 14-18 years (mean age 16.2; SD=1.0) of the city of Florianópolis, Southern Brazil, in 2001. Percent fat estimated based on skinfold measurements (> or =25% in males and > or =30% in females) was used as a gold-standard for determining specificity and sensitivity of BMI classification criteria among adolescents. The different cutoff points used for classifying BMI in general resulted in similar prevalence of overweight (p>0.05). Sensitivity of the evaluated criteria was high for males (85.4% to 91.7%) and low for females (33.8 to 52.8%). Specificity of all criteria was high for both sexes (83.6% to 98.8%). Estimates of prevalence of obesity among adolescents using different BMI classification criteria were similar and highly specific for both sexes, but sensitivity for females was low.

  4. Catching a glimpse of working memory: top-down capture as a tool for measuring the content of the mind.

    PubMed

    Lange, Nicholas D; Thomas, Rick P; Buttaccio, Daniel R; Davelaar, Eddy J

    2012-11-01

    This article outlines a methodology for probing working memory (WM) content in high-level cognitive tasks (e.g., decision making, problem solving, and memory retrieval) by capitalizing on attentional and oculomotor biases evidenced in top-down capture paradigms. This method would be of great use, as it could measure the information resident in WM at any point in a task and, hence, track information use over time as tasks dynamically evolve. Above and beyond providing a measure of information occupancy in WM, such a method would benefit from sensitivity to the specific activation levels of individual items in WM. This article additionally forwards a novel fusion of standard free recall and visual search paradigms in an effort to assess the sensitivity of eye movements in top-down capture, on which this new measurement technique relies, to item-specific memory activation (ISMA). The results demonstrate eye movement sensitivity to ISMA in some, but not all, cases.

  5. High correlation of specific IgE sensitization between birch pollen, soy and apple allergens indicates pollen-food allergy syndrome among birch pollen allergic patients in northern China.

    PubMed

    Hao, Guo-Dong; Zheng, Yi-Wu; Wang, Zhi-Xiang; Kong, Xing-Ai; Song, Zhi-Jing; Lai, Xu-Xin; Spangfort, Michael D

    2016-05-01

    Birch pollen sensitization and associated pollen-food syndrome among Chinese allergic patients have not been investigated. Sera from 203 allergic patients from the northern part of China and collected during February to July 2014 were investigated. Specific immunoglobulin E (IgE) against birch pollen extract Bet v and major birch pollen allergen Bet v 1 were measured using the ADVIA Centaur. The presence of major apple allergen Mal d 1 and soy bean allergen Gly m 4 specific IgE was measured by ImmunoCAP 100. Among the 203 sera, 34 sera (16.7%) had specific IgE to Bet v and of these, 28 sera (82.4%) contained Bet v 1-specific IgE. Among the 28 sera with Bet v 1-specific IgE, 27 sera (96.4%) contained Mal d 1-specific IgE and 22 sera (78.6%) contained Gly m 4-specific IgE. Of the 34 Bet v-positive sera, 6 sera (17.6%) contained no specific IgE for Bet v 1, Mal d 1, or Gly m 4. Almost all Bet v-positive sera were donated during the birch pollen season. The prevalence of birch allergy among patients visiting health care during pollen season can be as high as 16.7% in Tangshan City. The majority of Chinese birch allergic patients are IgE-sensitized to the major birch pollen allergen Bet v 1 as well as to the major apple allergen Mal d 1 and soy bean allergen Gly m 4. A relatively high number of patients (17.6%) are IgE-sensitized to birch pollen allergen(s) other than Bet v 1. The high prevalence of specific IgE to Mal d 1 and Gly m 4 among Bet v 1-sensitized patients indicates that pollen-food allergy syndrome could be of clinical relevance in China.

  6. Development of sensitivity versus specificity for print in the visual word form area.

    PubMed

    Centanni, Tracy M; King, Livia W; Eddy, Marianna D; Whitfield-Gabrieli, Susan; Gabrieli, John D E

    2017-07-01

    An area near the left lateral occipito-temporal sulcus that responds preferentially to print has been designated as the visual word form area (VWFA). Research suggests that specialization in this brain region increases as reading expertise is achieved. Here we aimed to characterize that development in terms of sensitivity (response to printed words relative to non-linguistic faces) versus specificity (response to printed words versus line drawings of nameable objects) in typically reading children ages 7-14 versus young adults as measured by functional magnetic resonance imaging (fMRI). Relative to adults, children displayed equivalent sensitivity but reduced specificity. These findings suggest that sensitivity for print relative to non-linguistic stimuli develops relatively early in the VWFA in the course of reading development, but that specificity for printed words in VWFA is still developing through at least age 14. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Sensitivity to change of mobility measures in musculoskeletal conditions on lower extremities in outpatient rehabilitation settings.

    PubMed

    Navarro-Pujalte, Esther; Gacto-Sánchez, Mariano; Montilla-Herrador, Joaquina; Escolar-Reina, Pilar; Ángeles Franco-Sierra, María; Medina-Mirapeix, Francesc

    2018-01-12

    Prospective longitudinal study. To examine the sensitivity of the Mobility Activities Measure for lower extremities and to compare it to the sensitivity of the Physical Functioning Scale (PF-10) and the Patient-Specific Functional Scale (PSFS) at week 4 and week 8 post-hospitalization in outpatient rehabilitation settings. Mobility Activities Measure is a set of short mobility measures to track outpatient rehabilitation progress: its scales have shown good properties but its sensitivity to change has not been reported. Patients with musculoskeletal conditions were recruited at admission in three outpatient rehabilitation settings in Spain. Data were collected at admission, week 4 and week 8 from an initial sample of 236 patients (mean age ± SD = 36.7 ± 11.1). Mobility Activities Measure scales for lower extremity; PF-10; and PSFS. All the Mobility Activities Measure scales were sensitive to both positive and negative changes (the Standardized Response Means (SRMs) ranged between 1.05 and 1.53 at week 4, and between 0.63 and 1.47 at week 8). The summary measure encompassing the three Mobility Activities Measure scales detected a higher proportion of participants who had improved beyond the minimal detectable change (MDC) than detected by the PSFS and the PF-10 both at week 4 (86.64% vs. 69.81% and 42.23%, respectively) and week 8 (71.14% vs. 55.65% and 60.81%, respectively). The three Mobility Activities Measure scales assessing the lower extremity can be used across outpatient rehabilitation settings to provide consistent and sensitive measures of changes in patients' mobility. Implications for rehabilitation All the scales of the Mobility Activities Measure for the lower extremity were sensitive to both positive and negative change across the follow-up periods. Overall, the summary measure encompassing the three Mobility Activities Measure scales for the lower extremity appeared more sensitive to positive changes than the Physical Functioning Scale, especially during the first four weeks of treatment. The summary measure also detected a higher percentage of participants with positive change that exceeded the minimal detectable change than the Patient-Specific Functional Scale and the Physical Functioning Scale at the first follow-up period. By demonstrating their consistency and sensitivity to change, the three Mobility Activities Measures scales can now be considered in order to track patients' functional progress. Mobility Activities Measure can be therefore used in patients with musculoskeletal conditions across outpatient rehabilitation settings to provide estimates of change in mobility activities focusing on the lower extremity.

  8. Prediction of parturition in bitches utilizing continuous vaginal temperature measurement.

    PubMed

    Geiser, B; Burfeind, O; Heuwieser, W; Arlt, S

    2014-02-01

    The objective of this study was to determine sensitivity and specificity of a body temperature decline in bitches to predict parturition. Temperature loggers were placed into the vaginal cavity of 16 pregnant bitches on day 56-61 after estimated ovulation or first mating. This measurement technique has been validated previously and enabled continuous sampling of body temperature. The temperature loggers were expelled from the vagina before delivery of the first pup. The computed values for specificity (77-92%) were higher than sensitivity (53-69%), indicating a more precise prognosis of parturition not occurring. In conclusion, our findings may assist interpreting vaginal temperature measurements in order to predict parturition in bitches. © 2013 Blackwell Verlag GmbH.

  9. Blood glucose measurement by glucometer in comparison with standard method in diagnosis of neonatal hypoglycemia.

    PubMed

    Nayeri, Fatemeh; Shariat, Mamak; Mousavi Behbahani, Hamid Modarres; Dehghan, Padideh; Ebrahim, Bita

    2014-01-01

    Hypoglycemia is considered as a serious risk factor in neonates. In the majority of cases, it occurs with no clinical symptoms. Accordingly, early diagnosis is extremely imperative, which can also lead to less morbidity and mortality. The aim of this study was to assess the importance of screening blood glucose using glucometer (known as a quick and cost-effective diagnostic test) in comparison with laboratory method. A total of 219 neonates at risk of hypoglycemia were included in this study. Blood glucose was measured by glucometer and laboratory. In addition glucose level of capillary blood was measured by glucometer at the same time. Sensitivity and specificity of capillary blood glucose measurement by glucometer were 83.5%, 97.5% respectively (ppv=80%), (npv=98%). Capillary blood glucose measured by glucometer has an acceptable sensitivity and specificity in measurement of neonatal blood glucose. Therefore measurement by glucometer is recommended as a proper diagnostic test.

  10. Methods for Evaluating Mammography Imaging Techniques

    DTIC Science & Technology

    2000-06-01

    independent of disease prevalence . When test outcomes are dichotomous, sensitivity and specificity measure test accuracy. Sensitivity is the...phers were not provided with the disease prevalence in the The model we use accounts for within mammographer test set. Mammographers provided one

  11. Functional measures developed for clinical populations identified impairment among active workers with upper extremity disorders

    PubMed Central

    Gardner, Bethany T.; Dale, Ann Marie; Buckner-Petty, Skye; Rachford, Robert; Strickland, Jaime; Kaskutas, Vicki; Evanoff, Bradley

    2017-01-01

    Purpose Few studies have explored measures of function across a range of health outcomes in a general working population. Using four upper extremity (UE) case definitions from the scientific literature, we described the performance of functional measures of work, activities of daily living, and overall health. Methods A sample of 573 workers completed several functional measures: modified recall versions of the QuickDASH, Levine Functional Status Scale (FSS), DASH Work module (DASH-W), and standard SF-8 physical component score. We determined case status based on four UE case definitions: 1) UE symptoms, 2) UE musculoskeletal disorders (MSD), 3) carpal tunnel syndrome (CTS), and 4) work limitations due to UE symptoms. We calculated effect sizes for each case definition to show the magnitude of the differences that were detected between cases and non-cases for each case definition on each functional measure. Sensitivity and specificity analyses showed how well each measure identified functional impairments across the UE case definitions. Results All measures discriminated between cases and non-cases for each case definition with the largest effect sizes for CTS and work limitations, particularly for the modified FSS and DASH-W measures. Specificity was high and sensitivity was low for outcomes of UE symptoms and UE MSD in all measures. Sensitivity was high for CTS and work limitations. Conclusions Functional measures developed specifically for use in clinical, treatment-seeking populations may identify mild levels of impairment in relatively healthy, active working populations, but measures performed better among workers with CTS or those reporting limitations at work. PMID:26091980

  12. Diagnostic Cutoff Value for Ultrasonography of the Common Fibular Neuropathy at the Fibular Head

    PubMed Central

    2016-01-01

    Objective To establish the diagnostic cutoff value of ultrasonographic measurement for common fibular neuropathy (CFN) at the fibular head (FH). Methods Twenty patients with electrodiagnostically diagnosed CFN at the FH and 30 healthy controls were included in the study. The cross-sectional area (CSA) of sciatic nerve at mid-thigh level, common fibular nerve at popliteal fossa (PF), and common fibular (CF) nerve at FH were measured. Additionally, the difference of CF nerve CSA at the FH between symptomatic side and asymptomatic side (ΔSx–Asx), the ratio of CF nerve CSA at FH to at PF (FH/PF), and the ratio of CF nerve CSA at the FH symptomatic side to asymptomatic side (Ratio Sx–Asx) were calculated. Results CSA at the FH, FH/PF, ΔSx–Asx, and Ratio Sx–Asx showed significant differences between the patient and control groups. The cutoff value for diagnosing CFN at the FH was 11.7 mm2 for the CSA at the FH (sensitivity 85.0%, specificity 90.0%), 1.70 mm2 for the ΔSx–Asx (sensitivity 83.3%, specificity 97.0%), 1.11 for the FH/PF (sensitivity 47.1%, specificity 93.3%), and 1.24 for the Ratio Sx–Asx (sensitivity 72.2%, specificity 96.7%). Conclusion The ultrasonographic measurement and cutoff value could be a valuable reference in diagnosing CFN at the FH and improving diagnostic reliability and efficacy. PMID:28119836

  13. Enhanced sensitivity in detection of antiviral antibody responses using biotinylation of foot-and-mouth disease virus (FMDV) capsids.

    PubMed

    Kenney, Mary; Waters, Ryan A; Rieder, Elizabeth; Pega, Juan; Perez-Filguera, Mariano; Golde, William T

    2017-11-01

    Analysis of the immune response to infection of livestock by foot-and-mouth disease virus (FMDV) is most often reported as the serum antibody response to the virus. While measurement of neutralizing antibody has been sensitive and specific, measurements of the quality of the antibody response are less robust. Determining the immunoglobulin (Ig) isotype of the serum antibody response provides a deeper understanding of the biology of the response and more sensitive methods for these assays will facilitate analyses of B cell mediated immunity. We tested the hypothesis that using the virus as the molecular probe could be achieved by adding tags to the surface of the FMDV capsid, and that would enhance sensitivity in assays for anti-FMDV antibody responses. The use of a FLAG-tagged virus in these assays failed to yield improvement whereas chemically biotinylating the virus capsid resulted in significant enhancement of the signal. Here we describe methods using biotinylated virus for measuring anti-viral antibody in serum and antibody secreting cells (ASCs) in blood that are sensitive and specific. Finally, we describe using the biotinylated virus in flow cytometry where such assays should greatly enhance the analysis of anti-virus antibody producing B cells, allowing the investigator to focus on only the FMDV specific B cells when analyzing the development of the B cell response to either infection or vaccination. Published by Elsevier B.V.

  14. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    PubMed

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  15. Cut off values for abdominal obesity as a criterion of metabolic syndrome in an ethnic Kyrgyz population (Central Asian region).

    PubMed

    Mirrakhimov, Aibek E; Lunegova, Olga S; Kerimkulova, Alina S; Moldokeeva, Cholpon B; Nabiev, Malik P; Mirrakhimov, Erkin M

    2012-02-22

    People of different racial and ethnic backgrounds have a distinct pattern of central fat deposition, thus making it necessary to devise a race based approach for the diagnosis and evaluation of abdominal obesity (AO). This is the first study to determine the optimal waist circumference (WC) cutoff values for definition of AO in an ethnic Kyrgyz population. 323 persons of Kyrgyz ethnicity (183 women and 140 men), with a mean age of 51.8 ± 9.5 years old were included in the study. Measurement of blood pressure (BP), anthropometric data (including body mass index calculation and WC measurement), fasting blood sugar, serum lipid parameters and insulin were performed in all examined individuals. Insulin resistance (IR) was considered as HOMA index (insulin × fasting glucose/22.5) ≥ 2.77. Sensitivity and specificity for the presence of IR or two other criteria of MS (according to the international classification, 2009) were calculated by using receiver operating characteristic (ROC) curves for men and women separately. The optimal sensitivity and specificity obtained from the ROC curves for IR were 88 cm in women (sensitivity of 0.85, 95%CI (0.72-0.93), specificity of 0.58, 95%CI (0.49-0.66)) and 94 cm for men (sensitivity of 0.8, 95% CI (0.65-0.91), specificity of 0.61, 95% CI (0.51-0.71)). The data from the ROC curve for any two other MS criteria confirmed the results and the WC 88 cm in women (sensitivity of 0.82, 95% CI (0.72-0.9), specificity of 0.72, 95% CI (0.62-0.8)) and 94 cm in men (sensitivity of 0.74, 95% CI (0.62-0.84), specificity of 0.73, 95% CI (0.61-0.83)) were corresponded to the optimal sensitivity and specificity. WC ≥ 88 cm and ≥ 94 cm should be used as a criterion for the diagnosis of AO for Kyrgyz women and men respectively based on these results.

  16. Assessment of insulin sensitivity from measurements in fasting state and during an oral glucose tolerance test in obese children.

    PubMed

    Atabek, Mehmet Emre; Pirgon, Ozgur

    2007-02-01

    Few previous studies have examined the validity of the fasting glucose-to-insulin ratio (FGIR), homeostasis model assessment of insulin resistance (HOMA-IR) and quantitative insulin-sensitivity check index (QUICKI) in pediatric populations. To compare simple indices of insulin resistance calculated from fasting glucose and insulin levels with insulin sensitivity indices (area under the response curve [AUCinsulin], insulin sensitivity index [ISI-compositeL) determined by oral glucose tolerance testing (OGTT) in obese children. One hundred and forty-eight obese children and adolescents (86 girls and 62 boys, mean age: 10.86 +/- 3.08 years, mean body mass index (BMI): 27.7 +/- 4.2) participated in the study. OGTT was performed in all participants. After glucose and insulin measurements from OGTT, the children were divided into two groups according to the presence or absence of insulin resistance. Insulin sensitivity indices obtained from the OGTT were compared between the groups. The total plasma glucose response and insulin secretion were evaluated from the AUC estimated by the trapezoid rule. Cut-off points, and sensitivity and specificity calculations were based on insulin resistance with receiver operating characteristic curve (ROC) analysis. The prevalence of insulin resistance, glucose intolerance and dyslipidemia was 37.1%, 24.3% and 54% in obese children, respectively. The groups consisted of 93 children without insulin resistance (54 girls and 39 boys; mean age: 10.5 +/- 3.3 years; mean BMI: 27.0 +/- 4.2) and 55 children with insulin resistance (32 girls and 23 boys; mean age: 11.4 +/- 2.5 years; mean BMI: 27.9 +/- 3.9). There were significant differences in mean FGIR (10.0 +/- 7.2 vs 5.6 +/- 2.8, p < 0.001), HOMA-IR (3.2 +/- 2.3 vs 4.9 +/- 2.3, p < 0.001) and QUICKI (0.33 +/- 0.03 vs 0.30 +/- 0.02, p < 0.001) between the groups. The cut-off points for diagnosis of insulin resistance were < 5.6 for FGIR (sensitivity 61.8, specificity 76.3), > 2.7 for HOMA-IR (sensitivity 80, specificity 59.1), and < 0.328 for QUICKI (sensitivity 80, specificity 60.2). Indices derived from fasting samples for diagnosis of insulin sensitivity are reliable criteria in obese children and adolescents. HOMA-IR and QUICKI appeared to have similar sensitivity and specificity and to have higher sensitivity than FGIR.

  17. Assessing the validity and reliability of three indicators self-reported on the pregnancy risk assessment monitoring system survey.

    PubMed

    Ahluwalia, Indu B; Helms, Kristen; Morrow, Brian

    2013-01-01

    We investigated the reliability and validity of three self-reported indicators from the Pregnancy Risk Assessment Monitoring System (PRAMS) survey. We used 2008 PRAMS (n=15,646) data from 12 states that had implemented the 2003 revised U.S. Certificate of Live Birth. We estimated reliability by kappa coefficient and validity by sensitivity and specificity using the birth certificate data as the reference for the following: prenatal participation in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC); Medicaid payment for delivery; and breastfeeding initiation. These indicators were examined across several demographic subgroups. The reliability was high for all three measures: 0.81 for WIC participation, 0.67 for Medicaid payment of delivery, and 0.72 for breastfeeding initiation. The validity of PRAMS indicators was also high: WIC participation (sensitivity = 90.8%, specificity = 90.6%), Medicaid payment for delivery (sensitivity = 82.4%, specificity = 85.6%), and breastfeeding initiation (sensitivity = 94.3%, specificity = 76.0%). The prevalence estimates were higher on PRAMS than the birth certificate for each of the indicators except Medicaid-paid delivery among non-Hispanic black women. Kappa values within most subgroups remained in the moderate range (0.40-0.80). Sensitivity and specificity values were lower for Hispanic women who responded to the PRAMS survey in Spanish and for breastfeeding initiation among women who delivered very low birthweight and very preterm infants. The validity and reliability of the PRAMS data for measures assessed were high. Our findings support the use of PRAMS data for epidemiological surveillance, research, and planning.

  18. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  19. A Comparative Study of Skin Prick Test versus Serum-Specific IgE Measurement in Indian Patients with Bronchial Asthma and Allergic Rhinitis.

    PubMed

    Kumar, Raj; Gupta, Nitesh; Kanuga, Jayesh; Kanuga, Mansi

    2015-01-01

    Skin prick testing (SPT) is the 'gold standard' in the assessment of allergic sensitivity to inhalant allergens. Serum-specific immunoglobulin E (SSIgE) measurement is a complementary test. SPT is performed with antigen extracts from India while SSIgE utilises extracts derived from European antigens. To evaluate the performance of allergic assessment by SSIgE against cockroach, housefly and mosquito aeroallergens which are frequently implicated in driving respiratory allergies in India considering SPT as the 'gold standard'. Twenty patients (mean age 28.5 years; range 15-50 years) diagnosed to have bronchial asthma and/or rhinitis underwent SPT. The SSIgE levels were obtained at the same visit. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SSIgE testing were calculated using SPT as the 'gold standard'. The correlation between SPT grading and SSIgE levels was also evaluated. The sensitivity of SSIgE testing to each of the 3 aero-allergens was > 85%. The PPV of cockroach and mosquito SSIgE was > 85%; housefly SSIgE had PPV of 68.7%. The two tests were in agreement in 85% (cockroach), 90% (mosquito) and 55% (housefly). There was a significant correlation between the grades of SPT reactions and SSIgE levels. The SSIgE has higher sensitivity and PPV, but lacks specificity. Higher sensitivity with low specificity leads to increased false positive diagnosis of allergic disease. Unlike allergenic pollens, however, insect antigen extracts from different regions seem to give comparable results, and can thus, reliably be used in the evaluation of allergy.

  20. Paraneoplastic autoantibody panels: sensitivity and specificity, a retrospective cohort.

    PubMed

    Albadareen, Rawan; Gronseth, Gary; Goeden, Marcie; Sharrock, Matthew; Lechtenberg, Colleen; Wang, Yunxia

    2017-06-01

    Experts in the autoimmune paraneoplastic field recommend autoantibody testing as "panels" to improve the poor sensitivity of individual autoantibodies in detecting paraneoplastic neurological syndromes (PNS). The sensitivity of those panels was not reported to date in a fashion devoid of incorporation bias. We aimed to assess the collective sensitivity and specificity of one of the commonly used panels in detecting PNS. A single-centered retrospective cohort of all patients tested for paraneoplastic evaluation panel (PAVAL; test ID: 83380) over one year for the suspicion of PNS. Case adjudication was based on newly proposed diagnostic criteria in line with previously published literature, but modified to exclude serological status to avoid incorporation bias. Measures of diagnostic accuracy were subsequently calculated. Cases that failed to show association with malignancy within the follow-up time studied, reflecting a possibly pure autoimmune process was considered paraneoplastic-like syndromes. Out of 321 patients tested, 51 patients tested positive. Thirty-two patients met diagnostic criteria for paraneoplastic/paraneoplastic-like syndromes. The calculated collective sensitivity was 34% (95% CI: 17-53), specificity was 86% (95% CI: 81-90), Youden's index 0.2 and a positive clinical utility index 0.07 suggesting poor utility for case-detection. This is the first reported diagnostic accuracy measures of paraneoplastic panels without incorporation bias. Despite recommended panel testing to improve detection of PNS, sensitivity remains low with poor utility for case-detection. The high-calculated specificity suggests a possible role in confirming the condition in difficult cases suspicious for PNS, when enough supportive evidence is lacking on ancillary testing.

  1. Quantitative Shear Wave Velocity Measurement on Acoustic Radiation Force Impulse Elastography for Differential Diagnosis between Benign and Malignant Thyroid Nodules: A Meta-analysis.

    PubMed

    Liu, Bo-Ji; Li, Dan-Dan; Xu, Hui-Xiong; Guo, Le-Hang; Zhang, Yi-Feng; Xu, Jun-Mei; Liu, Chang; Liu, Lin-Na; Li, Xiao-Long; Xu, Xiao-Hong; Qu, Shen; Xing, Mingzhao

    2015-12-01

    The aim of this study was to evaluate the diagnostic performance of quantitative shear wave velocity (SWV) measurement on acoustic radiation force impulse (ARFI) elastography for differentiation between benign and malignant thyroid nodules using meta-analysis. The databases of PubMed and the Web of Science were searched. Studies published in English on assessment of the sensitivity and specificity of ARFI elastography for the differentiation of thyroid nodules were collected. The quantitative measurement of ARFI elastography was evaluated by SWV (m/s). Meta-Disc Version 1.4 software was used to describe and calculate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and summary receiver operating characteristic curves. We analyzed a total of 13 studies, which included 1,854 thyroid nodules (including 1,339 benign nodules and 515 malignant nodules) from 1,641 patients. The summary sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules by SWV were 0.81 (95% confidence interval [CI]: 0.77-0.84) and 0.84 (95% CI: 0.81-0.86), respectively. The pooled positive and negative likelihood ratios were 5.21 (95% CI: 3.56-7.62) and 0.23 (95% CI: 0.17-0.32), respectively. The pooled diagnostic odds ratio was 27.53 (95% CI: 14.58-52.01), and the area under the summary receiver operating characteristic curve was 0.91 (Q* = 0.84). In conclusion, SWV measurement on ARFI elastography has high sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules and can be used in combination with conventional ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. Sensitivity Analysis and Requirements for Temporally and Spatially Resolved Thermometry Using Neutron Resonance Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fernandez, Juan Carlos; Barnes, Cris William; Mocko, Michael Jeffrey

    This report is intended to examine the use of neutron resonance spectroscopy (NRS) to make time- dependent and spatially-resolved temperature measurements of materials in extreme conditions. Specifically, the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters is examined. Based on that examination, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful measurement.

  3. Accuracy of birth certificate head circumference measurements: Massachusetts, 2012-2013.

    PubMed

    Somerville, Nicholas J; Chen, Xiaoli; Heinke, Dominique; Stone, Sarah L; Higgins, Cathleen; Manning, Susan E; Pagnano, Sharon; Yazdy, Mahsa M; Anderka, Marlene

    2018-03-15

    Zika virus has recently emerged as a novel cause of microcephaly. CDC has asked states to rapidly ascertain and report cases of Zika-linked birth defects, including microcephaly. Massachusetts added head circumference to its birth certificate (BC) in 2011. The accuracy of head circumference measurements from state vital records data has not been reported. We sought to assess the accuracy of Massachusetts BC head circumference measurements by comparing them to measurements for 2,217 infants born during 2012-2013 captured in the Massachusetts Birth Defects Monitoring Program (BDMP) data system. BDMP contains information abstracted directly from infant medical records and served as the true head circumference value (i.e., gold standard) for analysis. We calculated the proportion of head circumference measurements in agreement between the BC and BDMP data. We assigned growth chart head circumference percentile categories to each BC and BDMP measurement, and calculated the sensitivity and specificity of BC-based categories to predict BDMP-based categories. No difference was found in head circumference measurements between the two sources in 77.9% (n = 1,727) of study infants. The sensitivity of BC-based head circumference percentile categories ranged from 85.6% (<3rd percentile) to 92.7% (≥90th percentile) and the specificity ranged from 97.6% (≥90th percentile) to 99.3% (<3rd percentile). BC head circumference measurements agreed with those abstracted from the medical chart the majority of the time. Head circumference measurements on the BC were more specific than sensitive across all standardized growth chart percentile categories. © 2017 Wiley Periodicals, Inc.

  4. Circulating Kidney Injury Molecule 1 Predicts Prognosis and Poor Outcome in Patients With Acetaminophen‐Induced Liver Injury

    PubMed Central

    Sabbisetti, Venkata S.; Francis, Ben; Jorgensen, Andrea L.; Craig, Darren G.N.; Simpson, Kenneth J.; Bonventre, Joseph V.; Park, B. Kevin; Dear, James W.

    2015-01-01

    Acute kidney injury in the context of acetaminophen (APAP; paracetamol)‐induced liver injury is an important predictor of the requirement for urgent liver transplantation (LT) to avoid death. However, the prognostic biomarker used to report kidney dysfunction (serum creatinine concentration) has suboptimal sensitivity and specificity. Kidney injury molecule 1 (KIM‐1) can be quantified in plasma as a sensitive and specific biomarker of kidney injury in both clinical and preclinical studies. Therefore, plasma KIM‐1 has potential as a sensitive prognostic biomarker of patient outcome post‐APAP overdose. In a cohort of APAP overdose patients (N = 74) with and without established liver injury, we quantified plasma KIM‐1 by immunoassay on the first day of admission to a LT unit and assessed its diagnostic performance to predict outcome compared with serum creatinine concentration. Day 1 plasma KIM‐1 was significantly elevated in patients that died or required LT, compared to spontaneous survivors (1,182 ± 251 vs. 214 ± 45 pg/mL; P < 0.005). Receiver operator characteristic analysis demonstrated the superiority of KIM‐1 (area under the curve [AUC]: 0.87; 95% confidence interval [CI]: 0.78‐0.95; 0.56 sensitivity at 0.95 specificity), compared with serum creatinine (AUC, 0.76; 95% CI: 0.64‐0.87; 0.08 sensitivity at 0.95 specificity) and other current prognostic indicators, when measured on the first day of enrollment into the study. Furthermore, KIM‐1 was found to be a statistically significant independent predictor of outcome at the 5% level (P < 0.0386) in a multivariable logistic regression model that considered all measured factors (pseudo‐R^2 = 0.895). Conclusion: Early measurement of plasma KIM‐1 represents a more sensitive predictor of patient outcome than serum creatinine concentration post‐APAP overdose. With further development, plasma KIM‐1 could significantly improve prognostic stratification. (Hepatology 2015;62:591–599 PMID:25891479

  5. Using ROC Curves to Choose Minimally Important Change Thresholds when Sensitivity and Specificity Are Valued Equally: The Forgotten Lesson of Pythagoras. Theoretical Considerations and an Example Application of Change in Health Status

    PubMed Central

    Froud, Robert; Abel, Gary

    2014-01-01

    Background Receiver Operator Characteristic (ROC) curves are being used to identify Minimally Important Change (MIC) thresholds on scales that measure a change in health status. In quasi-continuous patient reported outcome measures, such as those that measure changes in chronic diseases with variable clinical trajectories, sensitivity and specificity are often valued equally. Notwithstanding methodologists agreeing that these should be valued equally, different approaches have been taken to estimating MIC thresholds using ROC curves. Aims and objectives We aimed to compare the different approaches used with a new approach, exploring the extent to which the methods choose different thresholds, and considering the effect of differences on conclusions in responder analyses. Methods Using graphical methods, hypothetical data, and data from a large randomised controlled trial of manual therapy for low back pain, we compared two existing approaches with a new approach that is based on the addition of the sums of squares of 1-sensitivity and 1-specificity. Results There can be divergence in the thresholds chosen by different estimators. The cut-point selected by different estimators is dependent on the relationship between the cut-points in ROC space and the different contours described by the estimators. In particular, asymmetry and the number of possible cut-points affects threshold selection. Conclusion Choice of MIC estimator is important. Different methods for choosing cut-points can lead to materially different MIC thresholds and thus affect results of responder analyses and trial conclusions. An estimator based on the smallest sum of squares of 1-sensitivity and 1-specificity is preferable when sensitivity and specificity are valued equally. Unlike other methods currently in use, the cut-point chosen by the sum of squares method always and efficiently chooses the cut-point closest to the top-left corner of ROC space, regardless of the shape of the ROC curve. PMID:25474472

  6. Measuring Coverage in MNCH: Accuracy of Measuring Diagnosis and Treatment of Childhood Malaria from Household Surveys in Zambia

    PubMed Central

    Eisele, Thomas P.; Silumbe, Kafula; Yukich, Josh; Hamainza, Busiku; Keating, Joseph; Bennett, Adam; Miller, John M.

    2013-01-01

    Background To assess progress in the scale-up of rapid diagnostic tests and artemisinin-based combination therapies (ACTs) across Africa, malaria control programs have increasingly relied on standardized national household surveys to determine the proportion of children with a fever in the past 2 wk who received an effective antimalarial within 1–2 d of the onset of fever. Here, the validity of caregiver recall for measuring the primary coverage indicators for malaria diagnosis and treatment of children <5 y old is assessed. Methods and Findings A cross-sectional study was conducted in five public clinics in Kaoma District, Western Provence, Zambia, to estimate the sensitivity, specificity, and accuracy of caregivers' recall of malaria testing, diagnosis, and treatment, compared to a gold standard of direct observation at the health clinics. Compared to the gold standard of clinic observation, for recall for children with fever in the past 2 wk, the sensitivity for recalling that a finger/heel stick was done was 61.9%, with a specificity of 90.0%. The sensitivity and specificity of caregivers' recalling a positive malaria test result were 62.4% and 90.7%, respectively. The sensitivity and specificity of recalling that the child was given a malaria diagnosis, irrespective of whether a laboratory test was actually done, were 76.8% and 75.9%, respectively. The sensitivity and specificity for recalling that an ACT was given were 81.0% and 91.5%, respectively. Conclusions Based on these findings, results from household surveys should continue to be used for ascertaining the coverage of children with a fever in the past 2 wk that received an ACT. However, as recall of a malaria diagnosis remains suboptimal, its use in defining malaria treatment coverage is not recommended. Please see later in the article for the Editors' Summary PMID:23667337

  7. Measuring Sleep: Accuracy, Sensitivity, and Specificity of Wrist Actigraphy Compared to Polysomnography

    PubMed Central

    Marino, Miguel; Li, Yi; Rueschman, Michael N.; Winkelman, J. W.; Ellenbogen, J. M.; Solet, J. M.; Dulin, Hilary; Berkman, Lisa F.; Buxton, Orfeu M.

    2013-01-01

    Objectives: We validated actigraphy for detecting sleep and wakefulness versus polysomnography (PSG). Design: Actigraphy and polysomnography were simultaneously collected during sleep laboratory admissions. All studies involved 8.5 h time in bed, except for sleep restriction studies. Epochs (30-sec; n = 232,849) were characterized for sensitivity (actigraphy = sleep when PSG = sleep), specificity (actigraphy = wake when PSG = wake), and accuracy (total proportion correct); the amount of wakefulness after sleep onset (WASO) was also assessed. A generalized estimating equation (GEE) model included age, gender, insomnia diagnosis, and daytime/nighttime sleep timing factors. Setting: Controlled sleep laboratory conditions. Participants: Young and older adults, healthy or chronic primary insomniac (PI) patients, and daytime sleep of 23 night-workers (n = 77, age 35.0 ± 12.5, 30F, mean nights = 3.2). Interventions: N/A. Measurements and Results: Overall, sensitivity (0.965) and accuracy (0.863) were high, whereas specificity (0.329) was low; each was only slightly modified by gender, insomnia, day/night sleep timing (magnitude of change < 0.04). Increasing age slightly reduced specificity. Mean WASO/night was 49.1 min by PSG compared to 36.8 min/night by actigraphy (β = 0.81; CI = 0.42, 1.21), unbiased when WASO < 30 min/night, and overestimated when WASO > 30 min/night. Conclusions: This validation quantifies strengths and weaknesses of actigraphy as a tool measuring sleep in clinical and population studies. Overall, the participant-specific accuracy is relatively high, and for most participants, above 80%. We validate this finding across multiple nights and a variety of adults across much of the young to midlife years, in both men and women, in those with and without insomnia, and in 77 participants. We conclude that actigraphy is overall a useful and valid means for estimating total sleep time and wakefulness after sleep onset in field and workplace studies, with some limitations in specificity. Citation: Marino M; Li Y; Rueschman MN; Winkelman JW; Ellenbogen JM; Solet JM; Dulin H; Berkman LF; Buxton OM. Measuring sleep: accuracy, sensitivity, and specificity of wrist actigraphy compared to polysomnography. SLEEP 2013;36(11):1747-1755. PMID:24179309

  8. Differential sensitivity between a virtual reality (VR) balance module and clinically used concussion balance modalities

    PubMed Central

    Teel, Elizabeth F; Gay, Michael R; Arnett, Peter A; Slobounov, Semyon M

    2015-01-01

    Objective Balance assessments are part of the recommended clinical concussion evaluation, along with computerized neuropsychological testing and self-reported symptoms checklists. New technology has allowed for the creation of virtual reality (VR) balance assessments to be used in concussion care, but there is little information on the sensitivity and specificity of these evaluations. The purpose of this study is to establish the sensitivity and specificity of a VR balance module for detecting lingering balance deficits clinical concussion care. Design Retrospective, case-control study Setting Institutional research laboratory Participants Normal controls (n=94) and concussed participants (n=27) Interventions All participants completed a VR balance assessment paradigm. Concussed participants were diagnosed by a Certified Athletic Trainer or physician (with 48 hours post-injury) and tested in the lab between 7-10 days post-injury. ROC curves were performed in order to establish the VR module’s sensitivity and specificity for detecting lingering balance deficits. Main Outcome Measures Final balance score Results For the VR balance module, a cutoff score of 8.25 was established to maximize sensitivity at 85.7% and specificity at 87.8%. Conclusions The VR balance module has high sensitivity and specificity for detecting sub-acute balance deficits after concussive injury. PMID:26505696

  9. An in vitro human skin test for assessing sensitization potential.

    PubMed

    Ahmed, S S; Wang, X N; Fielding, M; Kerry, A; Dickinson, I; Munuswamy, R; Kimber, I; Dickinson, A M

    2016-05-01

    Sensitization to chemicals resulting in an allergy is an important health issue. The current gold-standard method for identification and characterization of skin-sensitizing chemicals was the mouse local lymph node assay (LLNA). However, for a number of reasons there has been an increasing imperative to develop alternative approaches to hazard identification that do not require the use of animals. Here we describe a human in-vitro skin explant test for identification of sensitization hazards and the assessment of relative skin sensitizing potency. This method measures histological damage in human skin as a readout of the immune response induced by the test material. Using this approach we have measured responses to 44 chemicals including skin sensitizers, pre/pro-haptens, respiratory sensitizers, non-sensitizing chemicals (including skin-irritants) and previously misclassified compounds. Based on comparisons with the LLNA, the skin explant test gave 95% specificity, 95% sensitivity, 95% concordance with a correlation coefficient of 0.9. The same specificity and sensitivity were achieved for comparison of results with published human sensitization data with a correlation coefficient of 0.91. The test also successfully identified nickel sulphate as a human skin sensitizer, which was misclassified as negative in the LLNA. In addition, sensitizers and non-sensitizers identified as positive or negative by the skin explant test have induced high/low T cell proliferation and IFNγ production, respectively. Collectively, the data suggests the human in-vitro skin explant test could provide the basis for a novel approach for characterization of the sensitizing activity as a first step in the risk assessment process. Copyright © 2015 John Wiley & Sons, Ltd.

  10. The efficacy, sensitivity, and specificity of strip meniscometry in conjunction with tear function tests in the assessment of tear meniscus.

    PubMed

    Ibrahim, Osama M A; Dogru, Murat; Ward, Samantha K; Matsumoto, Yukihiro; Wakamatsu, Tais Hitomi; Ishida, Katsushi; Tsuyama, Atsushi; Kojima, Takashi; Shimazaki, Jun; Tsubota, Kazuo

    2011-04-06

    To evaluate the specificity and sensitivity of strip meniscometry (SM) testing in conjunction with tear function tests in the diagnosis of dry eye (DE) disease and to investigate the effect of SM on reflex tearing. One hundred seven left eyes of 107 patients with definite DE disease according to the Japanese DE diagnostic criteria and 68 left eyes of 68 age- and sex-matched control subjects were studied. Tear meniscus height (TMH) measurements, fluorescein tear film break-up time (FTBUT), fluorescein (F) and rose bengal (RB) staining, and Schirmer's test-1 (ST) were also performed. The assessment of reflex tearing before and after SM application was assessed with a graticule scale at the slit lamp and by optical coherence tomography. The sensitivity and specificity of SM alone and in combination with tear function tests were also sought. The SM scores, TMH measurements, FTBUTs, and STs were significantly lower in dry eye patients than in the controls (P < 0.001). The RB and F staining scores were significantly higher in the dry eye group than in the control group (P < 0.001). The meniscometry strips did not induce significant changes in relation to reflex tearing. SM had an acceptable sensitivity and specificity. SM is a swift, noninvasive, promising method of assessing tear meniscus volume. The combined SM and FTBUT examination appears to be a sensitive approach to the assessment of dry eye disease.

  11. Comparison of the abbreviated minimal assessment of cognitive function in multiple sclerosis (aMACFIMS) and the brief international cognitive assessment for multiple sclerosis (BICAMS).

    PubMed

    Gromisch, Elizabeth S; Portnoy, Jeffrey G; Foley, Frederick W

    2018-05-15

    Cognitive impairment is a prevalent and often intrusive problem among persons with multiple sclerosis (PwMS). Valid and reliable assessments, including quick screening measures, are crucial. The Brief International Cognitive Assessment for MS (BICAMS) was developed for this reason. While it lends itself to use in locations where formal neuropsychological resources might be limited, it does not include measures of verbal fluency or executive functioning, domains assessed as part of the Minimal Assessment of Cognitive Function in MS (MACFIMS). Given previous evidence that shortened MACFIMS measures have strong criterion validity, this study aimed to determine which of these should be included in the abbreviated MACFIMS (aMACFIMS), and how the aMACFIMS compares to the BICAMS. One hundred forty-seven PwMS were included in the analyses. A stepwise logistic regression was used to determine the measures in the aMACFIMS. Receiver-operating-characteristic (ROC) curves assessed the classification accuracy, sensitivity, and specificity. The batteries' sensitivity, specificity, and predictive values were then compared. Compared to the BICAMS, the final aMACFIMS had higher specificity (87% versus 72%) and positive predictive value (86% versus 77%), but lower sensitivity (71% versus 81%). The aMACFIMS has several benefits, including reduced administration time and the addition of a verbal fluency/executive functioning measure. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Nuclear morphology for the detection of alterations in bronchial cells from lung cancer: an attempt to improve sensitivity and specificity.

    PubMed

    Fafin-Lefevre, Mélanie; Morlais, Fabrice; Guittet, Lydia; Clin, Bénédicte; Launoy, Guy; Galateau-Sallé, Françoise; Plancoulaine, Benoît; Herlin, Paulette; Letourneux, Marc

    2011-08-01

    To identify which morphologic or densitometric parameters are modified in cell nuclei from bronchopulmonary cancer based on 18 parameters involving shape, intensity, chromatin, texture, and DNA content and develop a bronchopulmonary cancer screening method relying on analysis of sputum sample cell nuclei. A total of 25 sputum samples from controls and 22 bronchial aspiration samples from patients presenting with bronchopulmonary cancer who were professionally exposed to cancer were used. After Feulgen staining, 18 morphologic and DNA content parameters were measured on cell nuclei, via image cytom- etry. A method was developed for analyzing distribution quantiles, compared with simply interpreting mean values, to characterize morphologic modifications in cell nuclei. Distribution analysis of parameters enabled us to distinguish 13 of 18 parameters that demonstrated significant differences between controls and cancer cases. These parameters, used alone, enabled us to distinguish two population types, with both sensitivity and specificity > 70%. Three parameters offered 100% sensitivity and specificity. When mean values offered high sensitivity and specificity, comparable or higher sensitivity and specificity values were observed for at least one of the corresponding quantiles. Analysis of modification in morphologic parameters via distribution analysis proved promising for screening bronchopulmonary cancer from sputum.

  13. Real-Time, Single-Step Bioassay Using Nanoplasmonic Resonator With Ultra-High Sensitivity

    NASA Technical Reports Server (NTRS)

    Zhang, Xiang (Inventor); Chen, Fanqing Frank (Inventor); Su, Kai-Hang (Inventor); Wei, Qi-Huo (Inventor); Ellman, Jonathan A. (Inventor); Sun, Cheng (Inventor)

    2014-01-01

    A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

  14. Real-time, single-step bioassay using nanoplasmonic resonator with ultra-high sensitivity

    DOEpatents

    Zhang, Xiang; Ellman, Jonathan A; Chen, Fanqing Frank; Su, Kai-Hang; Wei, Qi-Huo; Sun, Cheng

    2014-04-01

    A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

  15. New directions in diagnostic evaluation of insect allergy.

    PubMed

    Golden, David B K

    2014-08-01

    Diagnosis of insect sting allergy and prediction of risk of sting anaphylaxis are often difficult because tests for venom-specific IgE antibodies have a limited positive predictive value and do not reliably predict the severity of sting reactions. Component-resolved diagnosis using recombinant venom allergens has shown promise in improving the specificity of diagnostic testing for insect sting allergy. Basophil activation tests have been explored as more sensitive assays for identification of patients with insect allergy and for prediction of clinical outcomes. Measurement of mast cell mediators reflects the underlying risk for more severe reactions and limited clinical response to treatment. Measurement of IgE to recombinant venom allergens can distinguish cross-sensitization from dual sensitization to honeybee and vespid venoms, thus helping to limit venom immunotherapy to a single venom instead of multiple venoms in many patients. Basophil activation tests can detect venom allergy in patients who show no detectable venom-specific IgE in standard diagnostic tests and can predict increased risk of systemic reactions to venom immunotherapy, and to stings during and after stopping venom immunotherapy. The risk of severe or fatal anaphylaxis to stings can also be predicted by measurement of baseline serum tryptase or other mast cell mediators.

  16. Simultaneous ultramicroanalysis of both 17-keto-and 17beta-hydroxy androgens in biological fluids.

    PubMed

    Ganjam, V K

    1976-11-01

    Sensitive methods for quantifying androgens were lacking. Therefore, a relatively simple procedure for separating steroids was combined with highly specific assay methods so that eight androgens could be measured with high accuracy, precision and sensitivity. Semi-automated separations on Sephadex LH-20 columns used heptane:methylene chloride:ethanol:water (50:50:1:0.12) and a flow rate of 17.0 min/ml. The six peaks eluted contained androstenedine; androsterone, epiandrosterone and dihydrotestosterone; testosterone and dehydroepiandrosterone; 3alpha-androstanediol; 3beta-androstanediol; and androstenediol. Androstenedione, dehydroepiandrosterone and androstenediol were quantified using specific antisera (sensitivity less than or equal to 75 pg). Testosterone and dihydrotestosterone were measured by competitive protein-binding assays using rabbit TeBG (sensitivity less than or equal to 150 pg). 3alpha- and 3beta-androstanediol were similarly assayed using human TeBG (sensitivity approximately 150 pg). Androsterone was reduced with NaBH4 and the resulting 3alpha-androstanediol was assayed using human TeBG (sensitivity approximately 200 pg). Inter- and intra-assay variations were less than 10% for radioimmunoassays and less than 16% for competitive protein-binding assays over the entire dose response curve.

  17. Screening for cognitive dysfunction in ALS: validation of the Edinburgh Cognitive and Behavioural ALS Screen (ECAS) using age and education adjusted normative data.

    PubMed

    Pinto-Grau, Marta; Burke, Tom; Lonergan, Katie; McHugh, Caroline; Mays, Iain; Madden, Caoifa; Vajda, Alice; Heverin, Mark; Elamin, Marwa; Hardiman, Orla; Pender, Niall

    2017-02-01

    Cognitive and behavioural changes are an important aspect in Amyotrophic Lateral Sclerosis (ALS). The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) briefly assesses these changes in ALS. To validate the ECAS against a standardised neuropsychological battery and assess its sensitivity and specificity using age and education adjusted cut-off scores. 30 incident ALS cases were assessed on both, ECAS and neuropsychological battery. Age and education adjusted cut-off scores were created from a sample of 82 healthy controls. ECAS composite scores (Total, ALS Specific and Non-Specific) were highly correlated with battery composite scores. High correlations were also observed between ECAS and full battery cognitive domains and subtests. The ECAS Total, ALS Specific and Non-Specific scores were highly sensitive to cognitive impairment. ECAS ALS-Specific cognitive domains also evidenced high sensitivity. Individual subtest sensitivity was medium to low, suggesting that caution should be used when interpreting these scores. Low positive predictive values indicated the presence of false positives. Psychometric properties of the ECAS using age and education adjusted norms indicate that the ECAS, when used as an overall measure of cognitive decline, is highly sensitive. Further comprehensive assessment is required for patients that present as impaired on the ECAS.

  18. The measurement of boredom: differences between existing self-report scales.

    PubMed

    Mercer-Lynn, Kimberley B; Flora, David B; Fahlman, Shelley A; Eastwood, John D

    2013-10-01

    There are two commonly used measures of boredom: the Boredom Proneness Scale (BPS) and the Boredom Susceptibility Scale (ZBS). Although both were designed to measure the propensity to experience boredom (i.e., trait boredom), there are reasons to think they may not measure the same construct. The present research sought to evaluate this proposition in several stages. Specifically, relationships between the BPS, ZBS, and important causal (Study 1, N = 837), correlational (Study 2, N = 233), and outcome variables (Study 3, N = 137) were examined in university students. Taken together, results support the notion that the BPS and ZBS do not measure the same construct. Specifically, higher BPS scores were associated with higher levels of neuroticism, experiential avoidance, attentional and nonplanning impulsivity, anxiety, depression, dysphoria, and emotional eating. Conversely, higher ZBS scores were associated with higher levels of motor impulsivity, sensitivity to reward, gambling, and alcohol use and lower levels of neuroticism, experiential avoidance, and sensitivity to punishment.

  19. Measurement of wall thickness alone does not accurately assess the presence of left ventricular hypertrophy.

    PubMed

    Leibowitz, David; Planer, David; Ben-Ibgi, Fanny; Rott, David; Weiss, A Teddy; Bursztyn, Michael

    2007-02-01

    Clinical echocardiographic assessment of left ventricular hypertrophy (LVH) is generally performed by measuring wall thickness alone (WT). The objective of this study was to compare the assessment of LVH using the measurement of WT to that using indexed LV mass. Hypertensive patients underwent echocardiography with the measurement of LV WT and LV mass. For each patient, the presence of LVH was assessed by both methods with WT compared to the gold standard of LV mass index. In all, 92 patients (51M/41F) were entered, and in only 55 patients (60%) were the two methods concordant. There was a tendency for WT to underestimate LVH in females (sensitivity 37%, specificity 79%) and overestimate LVH in males (sensitivity 88%, specificity 56%). The measurement of WT alone overestimates LVH in males and underestimates LVH in females and should not be used as a surrogate marker for increased LV mass.

  20. Optimal search strategies for detecting health services research studies in MEDLINE

    PubMed Central

    Wilczynski, Nancy L.; Haynes, R. Brian; Lavis, John N.; Ramkissoonsingh, Ravi; Arnold-Oatley, Alexandra E.

    2004-01-01

    Background Evidence from health services research (HSR) is currently thinly spread through many journals, making it difficult for health services researchers, managers and policy-makers to find research on clinical practice guidelines and the appropriateness, process, outcomes, cost and economics of health care services. We undertook to develop and test search terms to retrieve from the MEDLINE database HSR articles meeting minimum quality standards. Methods The retrieval performance of 7445 methodologic search terms and phrases in MEDLINE (the test) were compared with a hand search of the literature (the gold standard) for each issue of 68 journal titles for the year 2000 (a total of 25 936 articles). We determined sensitivity, specificity and precision (the positive predictive value) of the MEDLINE search strategies. Results A majority of the articles that were classified as outcome assessment, but fewer than half of those in the other categories, were considered methodologically acceptable (no methodologic criteria were applied for cost studies). Combining individual search terms to maximize sensitivity, while keeping specificity at 50% or more, led to sensitivities in the range of 88.1% to 100% for several categories (specificities ranged from 52.9% to 97.4%). When terms were combined to maximize specificity while keeping sensitivity at 50% or more, specificities of 88.8% to 99.8% were achieved. When terms were combined to maximize sensitivity and specificity while minimizing the differences between the 2 measurements, most strategies for HSR categories achieved sensitivity and specificity of at least 80%. Interpretation Sensitive and specific search strategies were validated for retrieval of HSR literature from MEDLINE. These strategies have been made available for public use by the US National Library of Medicine at www.nlm.nih.gov/nichsr/hedges/search.html. PMID:15534310

  1. A machine learning framework involving EEG-based functional connectivity to diagnose major depressive disorder (MDD).

    PubMed

    Mumtaz, Wajid; Ali, Syed Saad Azhar; Yasin, Mohd Azhar Mohd; Malik, Aamir Saeed

    2018-02-01

    Major depressive disorder (MDD), a debilitating mental illness, could cause functional disabilities and could become a social problem. An accurate and early diagnosis for depression could become challenging. This paper proposed a machine learning framework involving EEG-derived synchronization likelihood (SL) features as input data for automatic diagnosis of MDD. It was hypothesized that EEG-based SL features could discriminate MDD patients and healthy controls with an acceptable accuracy better than measures such as interhemispheric coherence and mutual information. In this work, classification models such as support vector machine (SVM), logistic regression (LR) and Naïve Bayesian (NB) were employed to model relationship between the EEG features and the study groups (MDD patient and healthy controls) and ultimately achieved discrimination of study participants. The results indicated that the classification rates were better than chance. More specifically, the study resulted into SVM classification accuracy = 98%, sensitivity = 99.9%, specificity = 95% and f-measure = 0.97; LR classification accuracy = 91.7%, sensitivity = 86.66%, specificity = 96.6% and f-measure = 0.90; NB classification accuracy = 93.6%, sensitivity = 100%, specificity = 87.9% and f-measure = 0.95. In conclusion, SL could be a promising method for diagnosing depression. The findings could be generalized to develop a robust CAD-based tool that may help for clinical purposes.

  2. Performance of a time-resolved fluorescence immunoassay for measuring varicella-zoster virus immunoglobulin G levels in adults and comparison with commercial enzyme immunoassays and Merck glycoprotein enzyme immunoassay.

    PubMed

    Maple, P A C; Gray, J; Breuer, J; Kafatos, G; Parker, S; Brown, D

    2006-02-01

    Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.

  3. The Brief Early Childhood Screening Assessment: Preliminary Validity in Pediatric Primary Care.

    PubMed

    Fallucco, Elise M; Wysocki, Tim; James, Lauren; Kozikowski, Chelsea; Williams, Andre; Gleason, Mary M

    Brief, well-validated instruments are needed to facilitate screening for early childhood behavioral and emotional problems (BEPs). The objectives of this study were to empirically reduce the length of the Early Childhood Screening Assessment (ECSA) and to assess the validity and reliability of this shorter tool. Using caregiver ECSA responses for 2467 children aged 36 to 60 months seen in primary care, individual ECSA items were ranked on a scale ranging from "absolutely retain" to "absolutely delete." Items were deleted sequentially beginning with "absolutely delete" and going up the item prioritization list, resulting in 35 shorter versions of the ECSA. A separate primary care sample (n = 69) of mothers of children aged 18 to 60 months was used to determine the sensitivity and specificity of each shorter ECSA version using psychiatric diagnosis on the Diagnostic Infant and Preschool Assessment as the gold standard. The version with the optimal balance of sensitivity, specificity, and length was selected as the Brief ECSA. Associations between Brief ECSA scores and other pertinent measures were evaluated to estimate reliability and validity. A 22-item measure reflected the best combination of brevity, sensitivity and specificity. A cutoff score of 9 or higher on the 22-item Brief ECSA demonstrated acceptable sensitivity (89%) and specificity (85%) for predicting a psychiatric diagnosis. Brief ECSA scores correlated significantly and in expected directions with scores on pertinent measures and with demographic variables. The results indicate that the Brief ECSA has sound psychometric properties for identifying young children with BEPs in primary care.

  4. Use of the dye stain assay and ultraviolet light test for assessing vaginal insertion of placebo-filled applicators before and after sex.

    PubMed

    Keller, Marla J; Buckley, Niall; Katzen, Lauren L; Walsh, Jennifer; Friedland, Barbara; Littlefield, Sarah; Lin, Juan; Xue, Xiaonan; Cornelison, Terri; Herold, Betsy C; Einstein, Mark H

    2013-12-01

    Applicator dye staining and ultraviolet (UV) light have been used in trials to measure adherence, but not in the setting of before and after sex gel dosing (BAT-24). This study was designed to determine if semen or presex gel dosing impacts the sensitivity and specificity of a dye stain assay (DSA) for measuring vaginal insertion of placebo-filled applicators with BAT-24 dosing. Healthy monogamous couples received Microlax-type applicators (Tectubes, Åstorp, Sweden) filled with hydroxyethylcelluose placebo gel. Women were instructed to vaginally insert 1 dose of gel before and a second dose after sex and to return applicators within 48 hours after sex. Applicators were stained to detect semen, followed by UV then DSA, and scored by 2 readers. Positive and negative controls were randomly included in applicator batches. Fifteen couples completed the study. Each woman returned at least 6 applicators over a 30-day period. The sensitivity for insertion of postsex applicators was higher for UV (97%) compared with DSA (90%), and the specificity was similar (≥96%). For presex applicators, the sensitivity and specificity were higher for DSA (100%) compared with UV testing (87% sensitivity, 96% specificity). Among returned postsex applicators, 95% tested positive by UV compared with 87% by DSA. Agreement between readers was significantly better on the presex applicators for DSA than for UV, and for postsex readings, agreement was less than half that for UV, although the results were not statistically significant. Applicator tests are feasible for measuring adherence in trials with gel dosing before and after sex.

  5. The Use of Bacterial Repair Endonucleases in the Comet Assay.

    PubMed

    Collins, Andrew R

    2017-01-01

    The comet assay is a sensitive electrophoretic method for measuring DNA breaks at the level of single cells, used widely in genotoxicity experiments, in biomonitoring, and in fundamental research. Its sensitivity and range of application are increased by the incorporation of an extra step, after lysis of agarose-embedded cells, in which the DNA is digested with lesion-specific endonucleases (DNA repair enzymes of bacterial or phage origin). Enzymes with specificity for oxidized purines, oxidized pyrimidines, alkylated bases, UV-induced cyclobutane pyrimidine dimers, and misincorporated uracil have been employed. The additional enzyme-sensitive sites, over and above the strand breaks detected in the standard comet assay, give a quantitative estimate of the number of specific lesions present in the cells.

  6. An evaluation of purified Salmonella Typhi protein antigens for the serological diagnosis of acute typhoid fever.

    PubMed

    Tran Vu Thieu, Nga; Trinh Van, Tan; Tran Tuan, Anh; Klemm, Elizabeth J; Nguyen Ngoc Minh, Chau; Voong Vinh, Phat; Pham Thanh, Duy; Ho Ngoc Dan, Thanh; Pham Duc, Trung; Langat, Pinky; Martin, Laura B; Galan, Jorge; Liang, Li; Felgner, Philip L; Davies, D Huw; de Jong, Hanna K; Maude, Rapeephan R; Fukushima, Masako; Wijedoru, Lalith; Ghose, Aniruddha; Samad, Rasheda; Dondorp, Arjen M; Faiz, Abul; Darton, Thomas C; Pollard, Andrew J; Thwaites, Guy E; Dougan, Gordon; Parry, Christopher M; Baker, Stephen

    2017-08-01

    The diagnosis of typhoid fever is a challenge. Aiming to develop a typhoid diagnostic we measured antibody responses against Salmonella Typhi (S. Typhi) protein antigens and the Vi polysaccharide in a cohort of Bangladeshi febrile patients. IgM against 12 purified antigens and the Vi polysaccharide was measured by ELISA in plasma from patients with confirmed typhoid fever (n = 32), other confirmed infections (n = 17), and healthy controls (n = 40). ELISAs with the most specific antigens were performed on plasma from 243 patients with undiagnosed febrile disease. IgM against the S. Typhi protein antigens correlated with each other (rho > 0.8), but not against Vi (rho < 0.6). Typhoid patients exhibited higher IgM against 11/12 protein antigens and Vi than healthy controls and those with other infections. Vi, PilL, and CdtB exhibited the greatest sensitivity and specificity. Specificity and sensitivity was improved when Vi was combined with a protein antigen, generating sensitivities and specificities of 0.80 and >0.85, respectively. Applying a dynamic cut-off to patients with undiagnosed febrile disease suggested that 34-58% had an IgM response indicative of typhoid. We evaluated the diagnostic potential of several S. Typhi antigens; our assays give good sensitivity and specificity, but require further assessment in differing patient populations. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  7. Analysis of feline and canine allergen components in patients sensitized to pets.

    PubMed

    Ukleja-Sokołowska, Natalia; Gawrońska-Ukleja, Ewa; Żbikowska-Gotz, Magdalena; Socha, Ewa; Lis, Kinga; Sokołowski, Łukasz; Kuźmiński, Andrzej; Bartuzi, Zbigniew

    2016-01-01

    Component resolved allergen diagnosis allows for a precise evaluation of the sensitization profiles of patients sensitized to felines and canines. An accurate interpretation of these results allows better insight into the evolution of a given patients sensitizations, and allows for a more precise evaluation of their prognoses. 70 patients (42 women and 28 men, aged 18-65, with the average of 35.5) with a positive feline or canine allergy diagnosis were included in the research group. 30 patients with a negative allergy diagnosis were included in the control group. The total IgE levels of all patients with allergies as well as their allergen-specific IgE to feline and canine allergens were measured. Specific IgE levels to canine (Can f 1, Can f 2, Can f 3, Can f 5) and feline (Fel d 1, Fel d 2, Fel d 4) allergen components were also measured with the use of the ImmunoCap method. Monosensitization for only one canine or feline component was found in 30% of patients. As predicted, the main feline allergen was Fel d 1, which sensitized as many as 93.9% of patients sensitized to felines. Among 65 patients sensitized to at least one feline component, for 30 patients (46.2%) the only sensitizing feline component was Fel d 1. Only 19 patients in that group (63.3%) were not simultaneously sensitized to dogs and 11 (36.7%), the isolated sensitization to feline Fel d 1 notwithstanding, displayed concurrent sensitizations to one of the canine allergen components. Fel d 4 sensitized 49.2% of the research group.64.3% of patients sensitized to canine components had heightened levels of specific IgE to Can f 1. Monosensitization in that group occurred for 32.1% of the patients. Sensitization to Can f 5 was observed among 52.4% of the patients. Concurrent sensitizations to a few allergic components, not only cross-reactive but also originating in different protein families, are a significant problem for patients sensitized to animals.

  8. Use of the Dynamic Visual Acuity Test as a screener for community-dwelling older adults who fall.

    PubMed

    Honaker, Julie A; Shepard, Neil T

    2011-01-01

    Adequate function of the peripheral vestibular system, specifically the vestibulo-ocular reflex (VOR; a network of neural connections between the peripheral vestibular system and the extraocular muscles) is essential for maintaining stable vision during head movements. Decreased visual acuity resulting from an impaired peripheral vestibular system may impede balance and postural control and place an individual at risk of falling. Therefore, sensitive measures of the vestibular system are warranted to screen for the tendency to fall, alerting clinicians to recommend further risk of falling assessment and referral to a falling risk reduction program. Dynamic Visual Acuity (DVA) testing is a computerized VOR assessment method to evaluate the peripheral vestibular system during head movements; reduced visual acuity as documented with DVA testing may be sensitive to screen for falling risk. This study examined the sensitivity and specificity of the computerized DVA test with yaw plane head movements for identifying community-dwelling adults (58-78 years) who are prone to falling. A total of 16 older adults with a history of two or more unexplained falls in the previous twelve months and 16 age and gender matched controls without a history of falls in the previous twelve months participated. Computerized DVA with horizontal head movements at a fixed velocity of 120 deg/sec was measured and compared with the Dynamic Gait Index (DGI) a gold standard gait assessment measurement for identifying falling risk. Receiver operating characteristics (ROC) curve analysis and area under the ROC curve (AUC) were used to assess the sensitivity and specificity of the computerized DVA as a screening measure for falling risk as determined by the DGI. Results suggested a link between computerized DVA and the propensity to fall; DVA in the yaw plane was found to be a sensitive (92%) and accurate screening measure when using a cutoff logMAR value of >0.25.

  9. The use of hippocampal volumetric measurements to improve diagnostic accuracy in pediatric patients with mesial temporal sclerosis.

    PubMed

    Guzmán Pérez-Carrillo, Gloria J; Owen, Christopher; Schwetye, Katherine E; McFarlane, Spencer; Vellimana, Ananth K; Mar, Soe; Miller-Thomas, Michelle M; Shimony, Joshua S; Smyth, Matthew D; Benzinger, Tammie L S

    2017-06-01

    OBJECTIVE Many patients with medically intractable epilepsy have mesial temporal sclerosis (MTS), which significantly affects their quality of life. The surgical excision of MTS lesions can result in marked improvement or even complete resolution of the epileptic episodes. Reliable radiological diagnosis of MTS is a clinical challenge. The purpose of this study was to evaluate the utility of volumetric mapping of the hippocampi for the identification of MTS in a case-controlled series of pediatric patients who underwent resection for medically refractory epilepsy, using pathology as a gold standard. METHODS A cohort of 57 pediatric patients who underwent resection for medically intractable epilepsy between 2005 and 2015 was evaluated. On pathological investigation, this group included 24 patients with MTS and 33 patients with non-MTS findings. Retrospective quantitative volumetric measurements of the hippocampi were acquired for 37 of these 57 patients. Two neuroradiologists with more than 10 years of experience who were blinded to the patients' MTS status performed the retrospective review of MR images. To produce the volumetric data, MR scans were parcellated and segmented using the FreeSurfer software suite. Hippocampal regions of interest were compared against an age-weighted local regression curve generated with data from the pediatric normal cohort. Standard deviations and percentiles of specific subjects were calculated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined for the original clinical read and the expert readers. Receiver operating characteristic curves were generated for the methods of classification to compare results from the readers with the authors' results, and an optimal threshold was determined. From that threshold the sensitivity, specificity, PPV, and NPV were calculated for the volumetric analysis. RESULTS With the use of quantitative volumetry, a sensitivity of 72%, a specificity of 95%, a PPV of 93%, an NPV of 78%, and an area under the curve of 0.84 were obtained using a percentage difference of normalized hippocampal volume. The resulting specificity (95%) and PPV (93%) are superior to the original clinical read and to Reader A and Reader B's findings (range for specificity 74%-86% and for PPV 64%-71%). The sensitivity (72%) and NPV (78%) are comparable to Reader A's findings (73% and 81%, respectively) and are better than those of the original clinical read and of Reader B (sensitivity 45% and 63% and NPV 71% and 70%, respectively). CONCLUSIONS Volumetric measurement of the hippocampi outperforms expert readers in specificity and PPV, and it demonstrates comparable to superior sensitivity and NPV. Volumetric measurements can complement anatomical imaging for the identification of MTS, much like a computer-aided detection tool would. The implementation of this approach in the daily clinical workflow could significantly improve diagnostic accuracy.

  10. Improved Sensitivity of Spectroscopic Quantification of Stable Isotope Content Using Capillary Absorption Spectroscopy

    NASA Astrophysics Data System (ADS)

    Moran, J.; Wilcox Freeburg, E.; Kriesel, J.; Linley, T. J.; Kelly, J.; Coleman, M. L.; Christensen, L. E.; Vance, S.

    2016-12-01

    Spectroscopy-based platforms have recently risen to the forefront for making stable isotope measurements of methane, carbon dioxide, water, or other analytes. These spectroscopy systems can be relatively straightforward to operate (versus a mass spectrometry platform), largely relieve the analyst of mass interference artifacts, and many can be used in the field. Despite these significant advantages, however, existing spectroscopy techniques suffer from a lack of measurement sensitivity that can ultimately limit select applications including spatially resolved and compound-specific measurements. Here we present a capillary absorption spectroscopy (CAS) system that is designed to mitigate sensitivity issues in spectroscopy-based stable isotope evaluation. The system uses mid-wave infrared excitation generated from a continuous wave quantum cascade laser. Importantly, the sample `chamber' is a flexible capillary with a total volume of less than one cc. Proprietary coatings on the internal surface of the fiber improve optical performance, guiding the light to a detector and facilitating high levels of interaction between the laser beam and gaseous analytes. We present data demonstrating that a tapered hollow fiber cell, with an internal diameter that broadens toward the detector, reduces optical feedback to further improve measurement sensitivity. Sensitivity of current hollow fiber / CAS systems enable measurements of only 10's of picomoles CO2 while theoretical improvements should enable measurements of as little as 10's of femtomoles. Continued optimization of sample introduction and improvements to optical feedback are being explored. Software is being designed to provide rapid integration of data and generation of processed isotope measurements using a graphical user interface. Taken together, the sensitivity improvements of the CAS system under development could, when coupled to a laser ablation sampling device, enable up to 2 µm spatial resolution (roughly the size of a eukaryotic cell or multiple prokaryotic cells) or provide a basis for compounds specific stable isotope analysis of trace biomarkers. The small size and low weight of the system holds future potential for field and / or remote deployment.

  11. Accuracy of immunoassay and mass spectrometry urinary free cortisol in the diagnosis of Cushing's syndrome.

    PubMed

    Aranda, G; Careaga, M; Hanzu, F A; Patrascioiu, I; Ríos, P; Mora, M; Morales-Romero, B; Jiménez, W; Halperin, I; Casals, G

    2016-10-01

    Urinary free cortisol (UFC) determination by highly specific methods as mass spectrometry instead of commercially available antibody-based immunoassays is increasingly recommended. However, clinical comparisons of both analytical approaches in the screening of Cushing's syndrome (CS) are not available. The aim of this study was to evaluate the diagnostic value of mass spectrometry versus immunoassay measurements of 24 h-UFC in the screening of CS. Cross-sectional study of 33 histologically confirmed CS patients: 25 Cushing's disease, 5 adrenal CS and 3 ectopic CS; 92 non-CS patients; and 35 healthy controls. UFC by immunoassay (UFCxIA) and mass spectrometry (UFCxMS), urinary free cortisone (UFCo) and UFC:UFCo ratio were measured, together with creatinine-corrected values. Sensitivity, specificity, AUC and Landis and Koch concordance index were determined. AUC for UFCxIA and UFCxMS were 0.77 (CI 0.68-0.87) and 0.77 (CI 0.67-0.87) respectively, with a kappa coefficient 0.60 and strong Landis and Koch concordance index. The best calculated cutoff values were 359 nmol/24 h for UFCxIA (78 % sensitivity, 62 % specificity) and 258.1 nmol/24 h for UCFxMS (53 % sensitivity, 86 % specificity). The upper limit of UFCxIA and UCFxMS reference ranges were 344.7 and 169.5 nmol/24 h respectively. Sensitivity and specificity for CS diagnosis at these cutpoints were 84 and 56 % for UFCxIA and 81 and 54 % for UFCxMS. According to our data, both methods present a very similar diagnostic value. However, results suggest that lower cutoff points for mass spectrometry may be necessary in order to improve clinical sensitivity.

  12. Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Xuejiang; Tang, Keqi

    Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers wouldmore » ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode, also known as multiple reaction monitoring (MRM), is capable of quantitatively measuring hundreds of candidate protein biomarkers from a relevant clinical sample in a single analysis. The specificity, reproducibility and sensitivity could be as good as ELISA. Furthermore, SRM MS can also quantify protein isoforms and post-translational modifications, for which traditional antibody-based immunoassays often don’t exist.« less

  13. Combined use of fasting plasma glucose and glycated hemoglobin A1c in the screening of diabetes and impaired glucose tolerance.

    PubMed

    Hu, Yaomin; Liu, Wei; Chen, Yawen; Zhang, Ming; Wang, Lihua; Zhou, Huan; Wu, Peihong; Teng, Xiangyu; Dong, Ying; Zhou, Jia wen; Xu, Hua; Zheng, Jun; Li, Shengxian; Tao, Tao; Hu, Yumei; Jia, Yun

    2010-09-01

    The aim of this study is to assess the validity of combined use of fasting plasma glucose (FPG) and glycated hemoglobin A1c (HbA1c) as screening tests for diabetes and impaired glucose tolerance (IGT) in high-risk subjects. A total of 2,298 subjects were included. All subjects underwent a 75-g oral glucose tolerance test (OGTT) and HbA1c measurement. Receiver operating characteristic curve (ROC curve) analysis was used to examine the sensitivity and specificity of FPG and HbA1c for detecting diabetes and IGT, which was defined according to the 1999 World Health Organization (WHO) criteria. (1) Based on the ROC curve, the optimal cut point of FPG related to diabetes diagnosed by OGTT was 6.1 mmol/l that was associated with a sensitivity and specificity of 81.5 and 81.0%, respectively; The optimal cut point of HbA1c related to diabetes diagnosed by OGTT was 6.1%, which was associated with a sensitivity and specificity of 81.0 and 81.0%, respectively; The screening model using FPG > or = 6.1 mmol/l or HbA1c > or = 6.1% had sensitivity of 96.5% for detecting undiagnosed diabetes; the screening model using FPG > or = 6.1 mmol/l and HbA1c > or = 6.1% had specificity of 96.3% for detecting undiagnosed diabetes. (2) Based on the ROC curve, the optimal cut point of FPG related to IGT diagnosed by OGTT was 5.6 mmol/l that was associated with a sensitivity and specificity of 64.1 and 65.4%, respectively; The optimal cut point of HbA1c related to IGT diagnosed by OGTT was 5.6%, which was associated with a sensitivity and specificity of 66.2 and 51.0%, respectively; The screening model using FPG > or = 5.6 mmol/l or HbA1c > or = 5.6% had sensitivity of 87.9% for detecting undiagnosed IGT; The screening model using FPG > or = 5.6 mmol/l and HbA1c > or = 5.6% had specificity of 82.4% for detecting undiagnosed IGT. Compared with FPG or HbA1c alone, the simultaneous measurement of FPG and HbA1c (FPG and/or HbA1C) might be a more sensitive and specific screening tool for identifying high-risk individuals with diabetes and IGT at an early stage.

  14. Laser Doppler pulp vitality measurements: simulation and measurement

    NASA Astrophysics Data System (ADS)

    Ertl, T.

    2017-02-01

    Frequently pulp vitality measurement is done in a dental practice by pressing a frozen cotton pellet on the tooth. This method is subjective, as the patient's response is required, sometimes painful and has moderate sensitivity and specificity. Other methods, based on optical or electrical measurement have been published, but didńt find wide spread application in the dental offices. Laser Doppler measurement of the blood flow in the pulp could be an objective method to measure pulp vitality, but the influence of the gingival blood flow on the measurements is a concern. Therefore experiments and simulations were done to learn more about the gingival blood flow in relation to the pulpal blood flow and how to minimize the influence. First patient measurements were done to show the feasibility clinically. Results: Monte Carlo simulations and bench experiments simulating the blood flow in and around a tooth show that both basic configurations, transmission and reflection measurements are possible. Most favorable is a multi-point measurement with different distances from the gingiva. Preliminary sensitivity / specificity are promising and might allow an objective and painless measurement of tooth vitality.

  15. Electronic monitoring of treatment adherence and validation of alternative adherence measures in tuberculosis patients: a pilot study.

    PubMed

    van den Boogaard, Jossy; Lyimo, Ramsey A; Boeree, Martin J; Kibiki, Gibson S; Aarnoutse, Rob E

    2011-09-01

    To assess adherence to community-based directly observed treatment (DOT) among Tanzanian tuberculosis patients using the Medication Event Monitoring System (MEMS) and to validate alternative adherence measures for resource-limited settings using MEMS as a gold standard. This was a longitudinal pilot study of 50 patients recruited consecutively from one rural hospital, one urban hospital and two urban health centres. Treatment adherence was monitored with MEMS and the validity of the following adherence measures was assessed: isoniazid urine test, urine colour test, Morisky scale, Brief Medication Questionnaire, adapted AIDS Clinical Trials Group (ACTG) adherence questionnaire, pill counts and medication refill visits. The mean adherence rate in the study population was 96.3% (standard deviation, SD: 7.7). Adherence was less than 100% in 70% of the patients, less than 95% in 21% of them, and less than 80% in 2%. The ACTG adherence questionnaire and urine colour test had the highest sensitivities but lowest specificities. The Morisky scale and refill visits had the highest specificities but lowest sensitivities. Pill counts and refill visits combined, used in routine practice, yielded moderate sensitivity and specificity, but sensitivity improved when the ACTG adherence questionnaire was added. Patients on community-based DOT showed good adherence in this study. The combination of pill counts, refill visits and the ACTG adherence questionnaire could be used to monitor adherence in settings where MEMS is not affordable. The findings with regard to adherence and to the validity of simple adherence measures should be confirmed in larger populations with wider variability in adherence rates.

  16. Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.

    PubMed

    Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S

    2014-02-10

    Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.

  17. Combining measurements from three anatomical areas for glaucoma diagnosis using Fourier-domain optical coherence tomography.

    PubMed

    Loewen, Nils A; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Greenfield, David S; Schuman, Joel S; Varma, Rohit; Huang, David

    2015-09-01

    To improve the diagnostic power for glaucoma by combining measurements of peripapillary nerve fibre layer (NFL), macular ganglion cell complex (GCC) and disc variables obtained with Fourier-domain optical coherence tomography (FD-OCT) into the glaucoma structural diagnostic index (GSDI). In this observational, cross-sectional study of subjects from the Advanced Imaging of Glaucoma Study, GCC and NFL of healthy and perimetrical glaucoma subjects from four major academic referral centres of the Advanced Imaging of Glaucoma Study were mapped with the RTVue FD-OCT. Global loss volume and focal loss volume parameters were defined using NFL and GCC normative reference maps. Optimal weights for NFL, GCC and disc variables were combined using multivariate logistic regression to build the GSDI. Glaucoma severity was classified using the Enhanced Glaucoma Staging System (GSS2). Diagnostic accuracy was assessed by sensitivity, specificity and the area under the receiver operator characteristic curve (AUC). We analysed 118 normal eyes of 60 subjects, 236 matched eyes of 166 subjects with perimetrical glaucoma, and 105 eyes from a healthy reference group of 61 subjects. The GSDI included composite overall thickness and focal loss volume with weighted NFL and GCC components, as well as the vertical cup-to-disc ratio. The AUC of 0.922 from leave-one-out cross validation was better than the best component variable alone (p=0.047). The partial AUC in the high specificity region was also better (p=0.01), with a sensitivity of 69% at 99% specificity, and a sensitivity of 80.3% at 95% specificity. For GSS2 stages 3-5 the sensitivity was 98% at 99% specificity, and 100% at 95% specificity. Combining structural measurements of GCC, NFL and disc variables from FD-OCT created a GSDI that improved the accuracy for glaucoma diagnosis. NCT01314326. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Strategies to improve the accuracy of vision measurement by teachers in rural Chinese secondary schoolchildren: Xichang Pediatric Refractive Error Study (X-PRES) report no. 6.

    PubMed

    Sharma, Abhishek; Li, Liping; Song, Yue; Choi, Kai; Lam, Dennis S C; Zhang, Mingzhi; Zheng, Mingwei; Zhou, Zhongxia; Liu, Xiaojian; Wu, Bin; Congdon, Nathan

    2008-10-01

    To assess and improve the accuracy of lay screeners compared with vision professionals in detecting visual impairment in secondary schoolchildren in rural China. After brief training, 32 teachers and a team of vision professionals independently measured vision in 1892 children in Xichang. The children also underwent vision measurement by health technicians in a concurrent government screening program. Of 32 teachers, 28 (87.5%) believed that teacher screening was worthwhile. Sensitivity (93.5%) and specificity (91.2%) of teachers detecting uncorrected presenting visual acuity of 20/40 or less were better than for presenting visual acuity (sensitivity, 85.2%; specificity, 84.8%). Failure of teachers to identify children owning but not wearing glasses and teacher bias toward better vision in children wearing glasses explain the worse results for initial vision. Wearing glasses was the student factor most strongly predictive of inaccurate teacher screening (P < .001). The sensitivity and specificity of the government screening program detecting low presenting visual acuity were 86.7% and 28.7%, respectively. Teacher vision screening after brief training can achieve accurate results in this setting, and there is support among teachers for screening. Screening of uncorrected rather than presenting visual acuity is recommended in settings with a high prevalence of corrected and uncorrected refractive error. Low specificity in the government program renders it ineffective.

  19. Hapten-specific lymphocyte transformation in humans sensitized with NDMA or DNCB.

    PubMed Central

    SoebergB; Andersen, V

    1976-01-01

    The primary immune response to a contact sensitizing dose of para-N-dimethylnitrosaniline (NDMA) and dinitrochlorobenzene (DNCB) was obtained in humans and measured in vitro by increased thymidine incorporation into sensitized lymphocytes. No cross-reaction was found between these two haptens, and it is thus possible on two separate occasions to quantify and follow the primary cellular immune response in man. PMID:963911

  20. Measurement Invariance versus Selection Invariance: Is Fair Selection Possible?

    ERIC Educational Resources Information Center

    Borsman, Denny; Romeijn, Jan-Willem; Wicherts, Jelte M.

    2008-01-01

    This article shows that measurement invariance (defined in terms of an invariant measurement model in different groups) is generally inconsistent with selection invariance (defined in terms of equal sensitivity and specificity across groups). In particular, when a unidimensional measurement instrument is used and group differences are present in…

  1. Geriatric-specific triage criteria are more sensitive than standard adult criteria in identifying need for trauma center care in injured older adults.

    PubMed

    Ichwan, Brian; Darbha, Subrahmanyam; Shah, Manish N; Thompson, Laura; Evans, David C; Boulger, Creagh T; Caterino, Jeffrey M

    2015-01-01

    We evaluate the sensitivity of Ohio's 2009 emergency medical services (EMS) geriatric trauma triage criteria compared with the previous adult triage criteria in identifying need for trauma center care among older adults. We studied a retrospective cohort of injured patients aged 16 years or older in the 2006 to 2011 Ohio Trauma Registry. Patients aged 70 years or older were considered geriatric. We identified whether each patient met the geriatric and the adult triage criteria. The outcome measure was need for trauma center care, defined by surrogate markers: Injury Severity Score greater than 15, operating room in fewer than 48 hours, any ICU stay, and inhospital mortality. We calculated sensitivity and specificity of both triage criteria for both age groups. We included 101,577 patients; 33,379 (33%) were geriatric. Overall, 57% of patients met adult criteria and 68% met geriatric criteria. Using Injury Severity Score, for older adults geriatric criteria were more sensitive for need for trauma center care (93%; 95% confidence interval [CI] 92% to 93%) than adult criteria (61%; 95% CI 60% to 62%). Geriatric criteria decreased specificity in older adults from 61% (95% CI 61% to 62%) to 49% (95% CI 48% to 49%). Geriatric criteria in older adults (93% sensitivity, 49% specificity) performed similarly to the adult criteria in younger adults (sensitivity 87% and specificity 44%). Similar patterns were observed for other outcomes. Standard adult EMS triage guidelines provide poor sensitivity in older adults. Ohio's geriatric trauma triage guidelines significantly improve sensitivity in identifying Injury Severity Score and other surrogate markers of the need for trauma center care, with modest decreases in specificity for older adults. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  2. Population and High-Risk Group Screening for Glaucoma: The Los Angeles Latino Eye Study

    PubMed Central

    Francis, Brian A.; Vigen, Cheryl; Lai, Mei-Ying; Winarko, Jonathan; Nguyen, Betsy; Azen, Stanley

    2011-01-01

    Purpose. To evaluate the ability of various screening tests, both individually and in combination, to detect glaucoma in the general Latino population and high-risk subgroups. Methods. The Los Angeles Latino Eye Study is a population-based study of eye disease in Latinos 40 years of age and older. Participants (n = 6082) underwent Humphrey visual field testing (HVF), frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP) and central corneal thickness (CCT), and independent assessment of optic nerve vertical cup disc (C/D) ratio. Screening parameters were evaluated for three definitions of glaucoma based on optic disc, visual field, and a combination of both. Analyses were also conducted for high-risk subgroups (family history of glaucoma, diabetes mellitus, and age ≥65 years). Sensitivity, specificity, and receiver operating characteristic curves were calculated for those continuous parameters independently associated with glaucoma. Classification and regression tree (CART) analysis was used to develop a multivariate algorithm for glaucoma screening. Results. Preset cutoffs for screening parameters yielded a generally poor balance of sensitivity and specificity (sensitivity/specificity for IOP ≥21 mm Hg and C/D ≥0.8 was 0.24/0.97 and 0.60/0.98, respectively). Assessment of high-risk subgroups did not improve the sensitivity/specificity of individual screening parameters. A CART analysis using multiple screening parameters—C/D, HVF, and IOP—substantially improved the balance of sensitivity and specificity (sensitivity/specificity 0.92/0.92). Conclusions. No single screening parameter is useful for glaucoma screening. However, a combination of vertical C/D ratio, HVF, and IOP provides the best balance of sensitivity/specificity and is likely to provide the highest yield in glaucoma screening programs. PMID:21245400

  3. Multiple-foil microabrasion package (A0023)

    NASA Technical Reports Server (NTRS)

    Mcdonnell, J. A. M.; Ashworth, D. G.; Carey, W. C.; Flavill, R. P.; Jennison, R. C.

    1984-01-01

    The specific scientific objectives of this experiment are to measure the spatial distribution, size, velocity, radiance, and composition of microparticles in near-Earth space. The technological objectives are to measure erosion rates resulting from microparticle impacts and to evaluate thin-foil meteor 'bumpers'. The combinations of sensitivity and reliability in this experiment will provide up to 1000 impacts per month for laboratory analysis and will extend current sensitivity limits by 5 orders of magnitude in mass.

  4. Production of Furin-cleaved Papillomavirus Pseudovirions and their use for in vitro neutralization assays of L1 or L2-specific antibodies

    PubMed Central

    Wang, Joshua W; Matsui, Ken; Pan, Yuanji; Kwak, Kihyuck; Peng, Shiwen; Kemp, Troy; Pinto, Ligia; Roden, Richard B.S

    2015-01-01

    Immunization with Human Papillomavirus (HPV) L1 virus-like particles or L2 capsid protein elicits neutralizing antibodies that mediate protection. A high throughput and sensitive in vitro neutralization assay is therefore valuable for prophylactic HPV vaccine studies. Over several hours during infection of the genital tract, virions take on a distinct intermediate conformation, including a required furin cleavage of L2 at its N-terminus. This intermediate is an important target for neutralization by L2-specific antibody, but it is very transiently exposed during in vitro infection of most cell lines resulting in insensitive measurement for L2, but not L1-specific neutralizing antibodies. To model this intermediate, we describe a protocol to generate furin-cleaved HPV pseudovirions (fc-PsV) which deliver an encapsidated reporter plasmid to facilitate infectivity measurements. We also describe a protocol for use of fc-PsV in a high throughput in vitro neutralization assay for the sensitive measurement of both L1 and L2-specific neutralizing antibodies. PMID:26237105

  5. Using the brief observation of social communication change (BOSCC) to measure autism-specific development.

    PubMed

    Kitzerow, Janina; Teufel, Karoline; Wilker, Christian; Freitag, Christine M

    2016-09-01

    To date no reliable and objective, change sensitive instrument for autistic symptoms is available. The brief observation of social communication change (BOSCC) was specifically developed to measure change of core autistic symptoms, for example, for use as outcome measure in early intervention trials. This study investigated quality criteria of a preliminary research version of the BOSCC in N = 21 children with autism spectrum disorder (ASD) who had participated for 1 year in the Frankfurt early intervention program (FFIP). BOSCC rating was done on play based ADOS video scenes. Inter-rater agreement on the BOSCC average total was very high. The BOSCC showed a significant decrease of autistic symptoms after 1 year with a medium effect size. Symptom specific improvements were captured by the social communication subscale and most single items. The BOSCC showed comparable change sensitivity to other autism specific instruments. Future studies should focus on the finalized BOSCC version, and replicate findings in a larger sample. Autism Res 2016, 9: 940-950. © 2015 International Society for Autism Research, Wiley Periodicals, Inc. © 2015 International Society for Autism Research, Wiley Periodicals, Inc.

  6. Rapid quantification of color vision: the cone contrast test.

    PubMed

    Rabin, Jeff; Gooch, John; Ivan, Douglas

    2011-02-09

    To describe the design, specificity, and sensitivity of the cone contrast test (CCT), a computer-based, cone-specific (L, M, S) contrast sensitivity test for diagnosing type and severity of color vision deficiency (CVD). The CCT presents a randomized series of colored letters visible only to L, M or S cones in decreasing steps of cone contrast to determine L, M, and S letter-recognition thresholds. Sensitivity and specificity were determined by retrospective comparison of CCT scores to anomaloscope and pseudoisochromatic plate (PIP) results in 1446 applicants for pilot training. CVD was detected in 49 (3.4%) of 1446 applicants with hereditary red-green (protan or deutan) CVD detected in 47 (3.5%) of 1359 men and blue-yellow (tritan) in 2 of 1446. In agreement with the anomaloscope, the CCT showed 100% sensitivity for detection and categorization of CVD (40 deutan, 7 protan, 2 tritan). PIP testing showed lower sensitivity (80% detected; 20% missed) due in part to the applicant's prior experience and/or pretest preparation. CCT specificity for confirming normal color vision was 100% for L and M cone tests and 99.8% for S cones. The CCT has sensitivity and specificity comparable to anomaloscope testing and exceeds PIP sensitivity in practiced observers. The CCT provides a rapid (6 minutes), clinically expedient, measure of color vision for quantifying normal color performance, diagnosing type and severity of hereditary deficiency, and detection of acquired sensitivity loss due to ocular, neurologic, and/or systemic disease, as well as injury and physiological stressors, such as altitude and fatigue.

  7. Support Vector Machines to improve physiologic hot flash measures: application to the ambulatory setting.

    PubMed

    Thurston, Rebecca C; Hernandez, Javier; Del Rio, Jose M; De La Torre, Fernando

    2011-07-01

    Most midlife women have hot flashes. The conventional criterion (≥2 μmho rise/30 s) for classifying hot flashes physiologically has shown poor performance. We improved this performance in the laboratory with Support Vector Machines (SVMs), a pattern classification method. We aimed to compare conventional to SVM methods to classify hot flashes in the ambulatory setting. Thirty-one women with hot flashes underwent 24 h of ambulatory sternal skin conductance monitoring. Hot flashes were quantified with conventional (≥2 μmho/30 s) and SVM methods. Conventional methods had low sensitivity (sensitivity=.57, specificity=.98, positive predictive value (PPV)=.91, negative predictive value (NPV)=.90, F1=.60), with performance lower with higher body mass index (BMI). SVMs improved this performance (sensitivity=.87, specificity=.97, PPV=.90, NPV=.96, F1=.88) and reduced BMI variation. SVMs can improve ambulatory physiologic hot flash measures. Copyright © 2010 Society for Psychophysiological Research.

  8. The measurement of axillary moisture for the assessment of dehydration among older patients: a pilot study.

    PubMed

    Kinoshita, Kensuke; Hattori, Kazuya; Ota, Yoshio; Kanai, Takao; Shimizu, Miyuki; Kobayashi, Hiroyuki; Tokuda, Yasuharu

    2013-02-01

    Dry axilla can sometimes be found among dehydrated older patients. In this study, we measured the axillary moisture and assessed it as possible marker for dehydration. Twenty-nine older patients admitted with acute medical conditions participated in this study. Dehydration was diagnosed by the calculated serum osmolality of greater than 295 mOsm/L. The moisture of axilla was measured by a skin moisture impedance meter which was applied at the center of axilla of patients. 11 patients (7 males and 4 females) were diagnosed as dehydrated and 18 patients (10 males and 8 females) were diagnosed as non-dehydrated. The mean axillary moisture (33%) in the dehydrated group was significantly lower than that (42%) in the non-dehydrated group (p<0.05). The axillary moisture ≥50% showed the sensitivity of 88%. The axillary moisture <30% showed the specificity of 91%. Use of a single cutoff value of 40% moisture produced the sensitivity of 59% and the specificity of 9%. As for the physical signs, dry axilla had also moderate sensitivity and excellent specificity to detect dehydration. The measurement of the axillary moisture could help assess dehydration. Dehydration could be ruled out when the axillary moisture ≥50%, while it could be ruled-in when the axillary moisture is <30%. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Functional neuroimaging with default mode network regions distinguishes PTSD from TBI in a military veteran population.

    PubMed

    Raji, Cyrus A; Willeumier, Kristen; Taylor, Derek; Tarzwell, Robert; Newberg, Andrew; Henderson, Theodore A; Amen, Daniel G

    2015-09-01

    PTSD and TBI are two common conditions in veteran populations that can be difficult to distinguish clinically. The default mode network (DMN) is abnormal in a multitude of neurological and psychiatric disorders. We hypothesize that brain perfusion SPECT can be applied to diagnostically separate PTSD from TBI reliably in a veteran cohort using DMN regions. A group of 196 veterans (36 with PTSD, 115 with TBI, 45 with PTSD/TBI) were selected from a large multi-site population cohort of individuals with psychiatric disease. Inclusion criteria were peacetime or wartime veterans regardless of branch of service and included those for whom the traumatic brain injury was not service related. SPECT imaging was performed on this group both at rest and during a concentration task. These measures, as well as the baseline-concentration difference, were then inputted from DMN regions into separate binary logistic regression models controlling for age, gender, race, clinic site, co-morbid psychiatric diseases, TBI severity, whether or not the TBI was service related, and branch of armed service. Predicted probabilities were then inputted into a receiver operating characteristic analysis to compute sensitivity, specificity, and accuracy. Compared to PSTD, persons with TBI were older, male, and had higher rates of bipolar and major depressive disorder (p < 0.05). Baseline quantitative regions with SPECT separated PTSD from TBI in the veterans with 92 % sensitivity, 85 % specificity, and 94 % accuracy. With concentration scans, there was 85 % sensitivity, 83 % specificity and 89 % accuracy. Baseline-concentration (the difference metric between the two scans) scans were 85 % sensitivity, 80 % specificity, and 87 % accuracy. In separating TBI from PTSD/TBI visual readings of baseline scans had 85 % sensitivity, 81 % specificity, and 83 % accuracy. Concentration scans had 80 % sensitivity, 65 % specificity, and 79 % accuracy. Baseline-concentration scans had 82 % sensitivity, 69 % specificity, and 81 % accuracy. For separating PTSD from PTSD/TBI baseline scans had 87 % sensitivity, 83 % specificity, and 92 % accuracy. Concentration scans had 91 % sensitivity, 76 % specificity, and 88 % accuracy. Baseline-concentration scans had 84 % sensitivity, 64 % specificity, and 85 % accuracy. This study demonstrates the ability to separate PTSD and TBI from each other in a veteran population using functional neuroimaging.

  10. Imaging outcomes for trials of remyelination in multiple sclerosis

    PubMed Central

    Mallik, Shahrukh; Samson, Rebecca S; Wheeler-Kingshott, Claudia A M; Miller, David H

    2014-01-01

    Trials of potential neuroreparative agents are becoming more important in the spectrum of multiple sclerosis research. Appropriate imaging outcomes are required that are feasible from a time and practicality point of view, as well as being sensitive and specific to myelin, while also being reproducible and clinically meaningful. Conventional MRI sequences have limited specificity for myelination. We evaluate the imaging modalities which are potentially more specific to myelin content in vivo, such as magnetisation transfer ratio (MTR), restricted proton fraction f (from quantitative magnetisation transfer measurements), myelin water fraction and diffusion tensor imaging (DTI) metrics, in addition to positron emission tomography (PET) imaging. Although most imaging applications to date have focused on the brain, we also consider measures with the potential to detect remyelination in the spinal cord and in the optic nerve. At present, MTR and DTI measures probably offer the most realistic and feasible outcome measures for such trials, especially in the brain. However, no one measure currently demonstrates sufficiently high sensitivity or specificity to myelin, or correlation with clinical features, and it should be useful to employ more than one outcome to maximise understanding and interpretation of findings with these sequences. PET may be less feasible for current and near-future trials, but is a promising technique because of its specificity. In the optic nerve, visual evoked potentials can indicate demyelination and should be correlated with an imaging outcome (such as optic nerve MTR), as well as clinical measures. PMID:24769473

  11. Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.

    PubMed

    Smith, R F; Mather, H M; Ellard, G A

    1998-02-01

    The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.

  12. Comparison of performance of the test of memory malingering and word memory test in a criminal forensic sample.

    PubMed

    Fazio, Rachel L; Sanders, James Forrest; Denney, Robert L

    2015-06-01

    Compared with the amount of neuropsychological literature surrounding response bias in civil litigation, there is little regarding criminal cases. This study adds to the criminal forensic neuropsychological literature by comparing the Test of Memory Malingering (TOMM) and the Word Memory Test (WMT) in a criminal forensic setting utilizing a criterion-groups design. Subjects were classified into two groups based on their performance on at least two other freestanding performance validity tests. The WMT demonstrated good sensitivity (95.1%) but poor specificity (68.4%) when Genuine Memory Impaired Profiles (GMIPs) were not considered. Inclusion of GMIPs reduced the sensitivity to 56.1% but increased the specificity to 94.7%. The TOMM evidenced better sensitivity but poorer specificity than the WMT with GMIPs. Conjoint use of the tests was also considered. Receiver operating characteristics and other classification statistics for each measure are presented. Results support the use of these measures in a criminal forensic population. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Sensitivity, Specificity, PPV, and NPV for Predictive Biomarkers

    PubMed Central

    2015-01-01

    Molecularly targeted cancer drugs are often developed with companion diagnostics that attempt to identify which patients will have better outcome on the new drug than the control regimen. Such predictive biomarkers are playing an increasingly important role in precision oncology. For diagnostic tests, sensitivity, specificity, positive predictive value, and negative predictive are usually used as performance measures. This paper discusses these indices for predictive biomarkers, provides methods for their calculation with survival or response endpoints, and describes assumptions involved in their use. PMID:26109105

  14. A guide to unclassified sensitive information protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donahue, S.C.

    1996-11-14

    This document is a reference guide for CIC-Division employees who lead or participate in projects that use and/or produce unclassified sensitive information. It is intended for use on a case by case basis to develop project specific sensitive information handling procedures and standards. It contains criteria for identifying sensitive information and determining levels of sensitivity, and describes cost effective measures for protecting various levels of sensitive information. The goal of this document is to help establish good business practices that benefit both the Laboratory and its customers. Division personnel are encouraged to apply these guidelines.

  15. Non-invasive Glucose Measurements Using Wavelength Modulated Differential Photothermal Radiometry (WM-DPTR)

    NASA Astrophysics Data System (ADS)

    Guo, X.; Mandelis, A.; Zinman, B.

    2012-11-01

    Wavelength-modulated differential laser photothermal radiometry (WM-DPTR) is introduced for potential development of clinically viable non-invasive glucose biosensors. WM-DPTR features unprecedented glucose-specificity and sensitivity by combining laser excitation by two out-of-phase modulated beams at wavelengths near the peak and the baseline of a prominent and isolated mid-IR glucose absorption band. Measurements on water-glucose phantoms (0 to 300 mg/dl glucose concentration) demonstrate high sensitivity to meet wide clinical detection requirements ranging from hypoglycemia to hyperglycemia. The measurement results have been validated by simulations based on fully developed WM-DPTR theory. For sensitive and accurate glucose measurements, the key is the selection and tight control of the intensity ratio and the phase shift of the two laser beams.

  16. Improving the sensitivity and specificity of a bioanalytical assay for the measurement of certolizumab pegol.

    PubMed

    Smeraglia, John; Silva, John-Paul; Jones, Kieran

    2017-08-01

    In order to evaluate placental transfer of certolizumab pegol (CZP), a more sensitive and selective bioanalytical assay was required to accurately measure low CZP concentrations in infant and umbilical cord blood. Results & methodology: A new electrochemiluminescence immunoassay was developed to measure CZP levels in human plasma. Validation experiments demonstrated improved selectivity (no matrix interference observed) and a detection range of 0.032-5.0 μg/ml. Accuracy and precision met acceptance criteria (mean total error ≤20.8%). Dilution linearity and sample stability were acceptable and sufficient to support the method. The electrochemiluminescence immunoassay was validated for measuring low CZP concentrations in human plasma. The method demonstrated a more than tenfold increase in sensitivity compared with previous assays, and improved selectivity for intact CZP.

  17. Acute Sport-Related Concussion Screening for Collegiate Athletes Using an Instrumented Balance Assessment.

    PubMed

    Baracks, Joshua; Casa, Douglas J; Covassin, Tracey; Sacko, Ryan; Scarneo, Samantha E; Schnyer, David; Yeargin, Susan W; Neville, Christopher

    2018-06-13

      Without a true criterion standard assessment, the sport-related concussion (SRC) diagnosis remains subjective. Inertial balance sensors have been proposed to improve acute SRC assessment, but few researchers have studied their clinical utility.   To determine if group differences exist when using objective measures of balance in a sample of collegiate athletes with recent SRCs and participants serving as the control group and to calculate sensitivity and specificity to determine the diagnostic utility of the inertial balance sensor for acute SRC injuries.   Cohort study.   Multicenter clinical trial.   We enrolled 48 participants with SRC (age = 20.62 ± 1.52 years, height = 179.76 ± 10.00 cm, mass = 83.92 ± 23.22 kg) and 45 control participants (age = 20.85 ± 1.42 years, height = 177.02 ± 9.59 cm, mass = 74.61 ± 14.92 kg) at 7 clinical sites in the United States. All were varsity or club collegiate athletes, and all participants with SRC were tested within 72 hours of SRC.   Balance performance was assessed using an inertial balance sensor. Two measures (root mean square [RMS] sway and 95% ellipse sway area) were analyzed to represent a range of general balance measures. Balance assessments were conducted in double-legged, single-legged, and tandem stances.   A main effect for group was associated with the root mean square sway measure ( F 1,91 = 11.75, P = .001), with the SRC group demonstrating balance deficits compared with the control group. We observed group differences in the 95% ellipse sway area measure for the double-legged ( F 1,91 = 11.59, P = .001), single-legged ( F 1,91 = 6.91, P = .01), and tandem ( F 1,91 = 7.54, P = .007) stances. Sensitivity was greatest using a cutoff value of 0.5 standard deviations (54% [specificity = 71%]), whereas specificity was greatest using a cutoff value of 2 standard deviations (98% [sensitivity = 33%]).   Inertial balance sensors may be useful tools for objectively measuring balance during acute SRC evaluation. However, low sensitivity suggests that they may be best used in conjunction with other assessments to form a comprehensive screening that may improve sensitivity.

  18. Use of the Dye Stain Assay and Ultraviolet Light Test for Assessing Vaginal Insertion of Placebo-filled Applicators Before and After Sex

    PubMed Central

    Keller, Marla J.; Buckley, Niall; Katzen, Lauren L.; Walsh, Jennifer; Friedland, Barbara; Littlefield, Sarah; Lin, Juan; Xue, Xiaonan; Cornelison, Terri; Herold, Betsy C.; Einstein, Mark H.

    2014-01-01

    Background Applicator dye staining and ultraviolet (UV) light have been used in trials to measure adherence, but not in the setting of before and after sex gel dosing (BAT-24). This study was designed to determine if semen or pre-sex gel dosing impacts the sensitivity and specificity of a dye stain assay (DSA) for measuring vaginal insertion of placebo-filled applicators with BAT-24 dosing. Methods Healthy monogamous couples received Microlax®-type applicators filled with hydroxyethylcelluose placebo gel. Women were instructed to vaginally insert one dose of gel before and a second dose after sex and to return applicators within 48 hours after sex. Applicators were stained to detect semen followed by UV then DSA and scored by two readers. Positive and negative controls were randomly included in applicator batches. Results Fifteen couples completed the study. Each female returned at least six applicators over a 30-day period. The sensitivity for insertion of post-sex applicators was higher for UV (97%) compared to DSA (90%) and the specificity was similar (≥96%). For pre-sex applicators, the sensitivity and specificity were higher for DSA (100%) compared to UV testing (87% sensitivity, 96% specificity). Among returned post-sex applicators, 95% tested positive by UV compared to 87% by DSA. Agreement between readers was significantly better on the pre-sex applicators for DSA than for UV and for post-sex readings agreement was less than half that for UV, although the results were not statistically significant. Conclusions Applicator tests are feasible for measuring adherence in trials with gel dosing before and after sex. PMID:24220355

  19. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    PubMed

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  20. Evaluation of clinical measures and different criteria for diagnosis of adult-onset Still's disease in a Chinese population.

    PubMed

    Jiang, Lindi; Wang, Zhen; Dai, Xiaomin; Jin, Xuejuan

    2011-04-01

    To determine the value of clinical measures in diagnosis of adult-onset Still's disease (AOSD), and to identify the optimal set of proposed classification criteria, in a Chinese population. A total of 70 patients with AOSD and 140 non-AOSD inpatients with fever were retrospectively identified at Zhongshan Hospital, Shanghai, from January 2003 to December 2009. Clinical measures and 4 sets of diagnostic criteria (Yamaguchi, Calabro, Cush, and Reginato) were evaluated by sensitivity, specificity, positive/negative predictive value (PPV, NPV), and positive/negative likelihood ratio (PLR, NLR) for diagnosis of AOSD. In our series, higher sensitivity included hyperpyrexia (temperature ≥ 39°C, 94.29%), arthralgia (80.0%), polymorphonuclear neutrophils (PMN) ≥ 75% (84.29%), serum ferritin ≥ 2-fold the upper normal value (90.0%), negative antinuclear antibodies (85.29%), and rheumatoid factor (84.38%); while higher specificity included transient erythema (98.57%), sore throat (85.0%), leukocytes ≥ 15,000/mm(3) (87.86%), and PMN ≥ 85% (85.0%). Rash, arthralgia, and sore throat were found to have better sensitivity and specificity (PLR 3.29-4.86). Leukocytes ≥ 10,000/mm(3), PMN ≥ 80%, and serum ferritin ≥ 5-fold the upper normal limit were set as critical points. The Reginato criteria set had the highest specificity, 99.29%. The Yamaguchi set had the highest sensitivity, 78.57%, with a better accuracy of 87.14%. The Yamaguchi diagnostic criteria had better accuracy in Chinese patients. Indicators such as rash, arthralgia, sore throat, leukocytes ≥ 10,000/mm(3), PMN ≥ 80%, and serum ferritin ≥ 5-fold the upper normal limit were helpful for diagnosis of AOSD. We recommend using these indicators in combination instead of alone.

  1. Prediction of gestational diabetes mellitus in the first trimester: comparison of C-reactive protein, fasting plasma glucose, insulin and insulin sensitivity indices.

    PubMed

    Ozgu-Erdinc, A Seval; Yilmaz, Saynur; Yeral, M Ilkin; Seckin, K Doga; Erkaya, Salim; Danisman, A Nuri

    2015-11-01

    To develop a predictive index based on high sensitivity C-reactive protein (hs-CRP), fasting plasma glucose (FPG) and fasting plasma insulin (FPI) measurements for early diagnosis of gestational diabetes mellitus (GDM). Healthy pregnant women who were screened for GDM during their first antenatal visit were included in this retrospective cohort study. FPG, FPI and serum hs-CRP concentrations were measured between weeks 11 and 14. A two-step glucose challenge test was carried out between gestational weeks 24 and 28. Fasting glucose/insulin ratio (FIGR), Homeostatic Model Assessment Insulin Resistance (HOMA-IR), HOMA-β indices and Quantitative Insulin Sensitivity Check Index (QUICKI) were used to estimate insulin sensitivity and β-cell function. Of the 450 women who were eligible for the study, 49 (11.2%) were diagnosed with GDM at weeks 24-28. The median FPG and hs-CRP levels were higher in the GDM diagnosed women compared to the others. Comparison of accuracy measures resulted in the highest specificity (87.2%; 95% CI 83.5-90.1) and diagnostic odds ratio (3.9; 95% CI 2.1-7.6) for hs-CRP. FPG and hs-CRP in the first trimester are correlated with later development of GDM in the pregnancy. In our study, FPG provided a better sensitivity while hs-CRP exhibited a better specificity for prediction of GDM.

  2. Diagnosis of breast cancer using elastic-scattering spectroscopy: preliminary clinical results

    NASA Astrophysics Data System (ADS)

    Bigio, Irving J.; Brown, Stephen G.; Briggs, Gavin M.; Kelley, Christine; Lakhani, Sunil; Pickard, David; Ripley, Paul M.; Rose, Ian; Saunders, Christobel

    2000-04-01

    We report on the first stages of a clinical study designed to test elastic-scattering spectroscopy, medicated by fiberoptic probes, for three specific clinical applications in breast-tissue diagnosis: (1) a transdermal-needle (interstitial) measurement for instant diagnosis with minimal invasiveness similar to fine-needle aspiration but with sensitivity to a larger tissue volume, (2) a hand-held diagnostic probe for use in assessing tumor/resection margins during open surgery, and (3) use of the same probe for real-time assessment of the `sentinel' node during surgery to determine the presence or absence of tumor (metastatic). Preliminary results from in vivo measurements on 31 women are encouraging. Optical spectra were measured on 72 histology sites in breast tissue, and 54 histology sites in sentinel nodes. Two different artificial intelligence methods of spectral classification were studied. Artificial neural networks yielded sensitivities of 69% and 58%, and specificities of 85% and 93%, for breast tissue and sentinel nodes, respectively. Hierarchical cluster analysis yielded sensitivities of 67% and 91%, and specificities of 79% and 77%, for breast tissue and sentinel nodes, respectively. These values are expected to improve as the data sets continue to grow and more sophisticated data preprocessing is employed. The study will enroll up to 400 patients over the next two years.

  3. A Comparison between Decision Tree and Random Forest in Determining the Risk Factors Associated with Type 2 Diabetes.

    PubMed

    Esmaily, Habibollah; Tayefi, Maryam; Doosti, Hassan; Ghayour-Mobarhan, Majid; Nezami, Hossein; Amirabadizadeh, Alireza

    2018-04-24

    We aimed to identify the associated risk factors of type 2 diabetes mellitus (T2DM) using data mining approach, decision tree and random forest techniques using the Mashhad Stroke and Heart Atherosclerotic Disorders (MASHAD) Study program. A cross-sectional study. The MASHAD study started in 2010 and will continue until 2020. Two data mining tools, namely decision trees, and random forests, are used for predicting T2DM when some other characteristics are observed on 9528 subjects recruited from MASHAD database. This paper makes a comparison between these two models in terms of accuracy, sensitivity, specificity and the area under ROC curve. The prevalence rate of T2DM was 14% among these subjects. The decision tree model has 64.9% accuracy, 64.5% sensitivity, 66.8% specificity, and area under the ROC curve measuring 68.6%, while the random forest model has 71.1% accuracy, 71.3% sensitivity, 69.9% specificity, and area under the ROC curve measuring 77.3% respectively. The random forest model, when used with demographic, clinical, and anthropometric and biochemical measurements, can provide a simple tool to identify associated risk factors for type 2 diabetes. Such identification can substantially use for managing the health policy to reduce the number of subjects with T2DM .

  4. Evaluation and comparison of statistical methods for early temporal detection of outbreaks: A simulation-based study

    PubMed Central

    Le Strat, Yann

    2017-01-01

    The objective of this paper is to evaluate a panel of statistical algorithms for temporal outbreak detection. Based on a large dataset of simulated weekly surveillance time series, we performed a systematic assessment of 21 statistical algorithms, 19 implemented in the R package surveillance and two other methods. We estimated false positive rate (FPR), probability of detection (POD), probability of detection during the first week, sensitivity, specificity, negative and positive predictive values and F1-measure for each detection method. Then, to identify the factors associated with these performance measures, we ran multivariate Poisson regression models adjusted for the characteristics of the simulated time series (trend, seasonality, dispersion, outbreak sizes, etc.). The FPR ranged from 0.7% to 59.9% and the POD from 43.3% to 88.7%. Some methods had a very high specificity, up to 99.4%, but a low sensitivity. Methods with a high sensitivity (up to 79.5%) had a low specificity. All methods had a high negative predictive value, over 94%, while positive predictive values ranged from 6.5% to 68.4%. Multivariate Poisson regression models showed that performance measures were strongly influenced by the characteristics of time series. Past or current outbreak size and duration strongly influenced detection performances. PMID:28715489

  5. Value of high-sensitivity C-reactive protein assays in predicting atrial fibrillation recurrence: a systematic review and meta-analysis

    PubMed Central

    Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang

    2014-01-01

    Objectives We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Design Systematic review and meta-analysis. Data sources PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. Study eligibility criteria This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. Primary and secondary outcome measures We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. Results We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). Conclusions hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion. PMID:24556243

  6. Evaluation of Visual Field and Imaging Outcomes for Glaucoma Clinical Trials (An American Ophthalomological Society Thesis).

    PubMed

    Garway-Heath, David F; Quartilho, Ana; Prah, Philip; Crabb, David P; Cheng, Qian; Zhu, Haogang

    2017-08-01

    To evaluate the ability of various visual field (VF) analysis methods to discriminate treatment groups in glaucoma clinical trials and establish the value of time-domain optical coherence tomography (TD OCT) imaging as an additional outcome. VFs and retinal nerve fibre layer thickness (RNFLT) measurements (acquired by TD OCT) from 373 glaucoma patients in the UK Glaucoma Treatment Study (UKGTS) at up to 11 scheduled visits over a 2 year interval formed the cohort to assess the sensitivity of progression analysis methods. Specificity was assessed in 78 glaucoma patients with up to 11 repeated VF and OCT RNFLT measurements over a 3 month interval. Growth curve models assessed the difference in VF and RNFLT rate of change between treatment groups. Incident progression was identified by 3 VF-based methods: Guided Progression Analysis (GPA), 'ANSWERS' and 'PoPLR', and one based on VFs and RNFLT: 'sANSWERS'. Sensitivity, specificity and discrimination between treatment groups were evaluated. The rate of VF change was significantly faster in the placebo, compared to active treatment, group (-0.29 vs +0.03 dB/year, P <.001); the rate of RNFLT change was not different (-1.7 vs -1.1 dB/year, P =.14). After 18 months and at 95% specificity, the sensitivity of ANSWERS and PoPLR was similar (35%); sANSWERS achieved a sensitivity of 70%. GPA, ANSWERS and PoPLR discriminated treatment groups with similar statistical significance; sANSWERS did not discriminate treatment groups. Although the VF progression-detection method including VF and RNFLT measurements is more sensitive, it does not improve discrimination between treatment arms.

  7. [Validity of a standard questionnaire to assess physical activity for specific medical checkups and health guidance].

    PubMed

    Kawakami, Ryoko; Miyachi, Motohiko

    2010-10-01

    This study aimed to determine the validity of a standard questionnaire to assess amount of physical activity (PA) and cardiorespiratory fitness (VO2peak). A total of 483 men and women, aged 20 to 69 years, participated. The standard questionnaire included 3 items about exercise, PA, and walking speed. All questions were designed to require an answer of Yes or No. Subjects were classified into one of four groups regarding the number of Yes answers to the three questions, giving activity levels of 0 to 3. The amount of PA was measured objectively with a tn-axial accelerometer which could also calculate daily step counts, and the amounts of PA under 3 metabolic equivalents (METs) and at 3 METs or more. VO2peak. was measured by incremental cycle exercise tests with indirect calorimetry. The daily step counts, the amount of PA at 3 METs or more, and the VO2peak. were significantly higher in subjects who answered Yes to each question than in those who answered No. Sensitivity and specificity of each question were 62-73% and 45-71% for the amount of PA established with the "Exercise and Physical Activity Reference for Health Promotion 2006 (EPAR2006)". The sum of sensitivity and specificity was the highest when the cutoff value was activity level 2 (sensitivity 73%, specificity 68%). Sensitivity and specificity for VO2max established by EPAR2006 were lower than those for the amount of PA. These results suggest that only answering simple questions with a standard questionnaire is sufficient for estimation of PA levels for specific medical checkups and health guidance, even though the accuracy is somewhat limited.

  8. Sensitivity and responsiveness of the health-related quality of life in stroke patients-40 (HRQOLISP-40) scale.

    PubMed

    Vincent-Onabajo, Grace O; Owolabi, Mayowa O; Hamzat, Talhatu K

    2014-01-01

    To investigate the sensitivity and responsiveness of the Health-Related Quality of Life in Stroke Patients-40 (HRQOLISP-40) scale in evaluating stroke patients from onset to 12 months. Fifty-five patients with first-incidence stroke were followed-up for 12 months. The HRQOLISP-40 scale was used to assess health-related quality of life (HRQOL) while stroke severity was assessed with the Stroke Levity Scale. Sensitivity to change was assessed by analyzing changes in the HRQOLISP-40 scores between pairs of months with paired samples t-test. Standardized effect size (SES) and standardized response mean (SRM) were used to express responsiveness. Overall HRQOL and domains in the physical sphere of the HRQOLISP-40 were sensitive to change at different time intervals in the first 12 months post-stroke. Marked responsiveness (SES and SRM >0.7) was demonstrated by the overall scale, and the physical, psycho-emotional and cognitive domains at varying time intervals. For instance, SRM was greater than 0.7 between 1 and 6, 3 and 12, 1 and 9, and 1 and 12 months for both the physical and psycho-emotional domains. The HRQOLISP-40 is a sensitive and responsive stroke-specific quality of life measure that can be used to evaluate the outcome of stroke rehabilitation. Enhancing the health-related quality of life (HRQOL) of stroke survivors can be regarded as the ultimate goal of stroke rehabilitation. Sensitive and responsive stroke-specific HRQOL measures are required for use in evaluative studies, and clinical trials and practice. The Health-Related Quality of Life in Stroke Patients-40 (HRQOLISP-40) is a sensitive and responsive stroke-specific scale.

  9. Pressure and cold pain threshold reference values in a large, young adult, pain-free population.

    PubMed

    Waller, Robert; Smith, Anne Julia; O'Sullivan, Peter Bruce; Slater, Helen; Sterling, Michele; McVeigh, Joanne Alexandra; Straker, Leon Melville

    2016-10-01

    Currently there is a lack of large population studies that have investigated pain sensitivity distributions in healthy pain free people. The aims of this study were: (1) to provide sex-specific reference values of pressure and cold pain thresholds in young pain-free adults; (2) to examine the association of potential correlates of pain sensitivity with pain threshold values. This study investigated sex specific pressure and cold pain threshold estimates for young pain free adults aged 21-24 years. A cross-sectional design was utilised using participants (n=617) from the Western Australian Pregnancy Cohort (Raine) Study at the 22-year follow-up. The association of site, sex, height, weight, smoking, health related quality of life, psychological measures and activity with pain threshold values was examined. Pressure pain threshold (lumbar spine, tibialis anterior, neck and dorsal wrist) and cold pain threshold (dorsal wrist) were assessed using standardised quantitative sensory testing protocols. Reference values for pressure pain threshold (four body sites) stratified by sex and site, and cold pain threshold (dorsal wrist) stratified by sex are provided. Statistically significant, independent correlates of increased pressure pain sensitivity measures were site (neck, dorsal wrist), sex (female), higher waist-hip ratio and poorer mental health. Statistically significant, independent correlates of increased cold pain sensitivity measures were, sex (female), poorer mental health and smoking. These data provide the most comprehensive and robust sex specific reference values for pressure pain threshold specific to four body sites and cold pain threshold at the dorsal wrist for young adults aged 21-24 years. Establishing normative values in this young age group is important given that the transition from adolescence to adulthood is a critical temporal period during which trajectories for persistent pain can be established. These data will provide an important research resource to enable more accurate profiling and interpretation of pain sensitivity in clinical pain disorders in young adults. The robust and comprehensive data can assist interpretation of future clinical pain studies and provide further insight into the complex associations of pain sensitivity that can be used in future research. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  10. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.

    2012-08-03

    Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the developmentmore » of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.« less

  11. Assessing behavioural changes in ALS: cross-validation of ALS-specific measures.

    PubMed

    Pinto-Grau, Marta; Costello, Emmet; O'Connor, Sarah; Elamin, Marwa; Burke, Tom; Heverin, Mark; Pender, Niall; Hardiman, Orla

    2017-07-01

    The Beaumont Behavioural Inventory (BBI) is a behavioural proxy report for the assessment of behavioural changes in ALS. This tool has been validated against the FrSBe, a non-ALS-specific behavioural assessment, and further comparison of the BBI against a disease-specific tool was considered. This study cross-validates the BBI against the ALS-FTD-Q. Sixty ALS patients, 8% also meeting criteria for FTD, were recruited. All patients were evaluated using the BBI and the ALS-FTD-Q, completed by a carer. Correlational analysis was performed to assess construct validity. Precision, sensitivity, specificity, and overall accuracy of the BBI when compared to the ALS-FTD-Q, were obtained. The mean score of the whole sample on the BBI was 11.45 ± 13.06. ALS-FTD patients scored significantly higher than non-demented ALS patients (31.6 ± 14.64, 9.62 ± 11.38; p < 0.0001). A significant large positive correlation between the BBI and the ALS-FTD-Q was observed (r = 0.807, p < 0.0001), and no significant correlations between the BBI and other clinical/demographic characteristics indicate good convergent and discriminant validity, respectively. 72% of overall concordance was observed. Precision, sensitivity, and specificity for the classification of severely impaired patients were adequate. However, lower concordance in the classification of mild behavioural changes was observed, with higher sensitivity using the BBI, most likely secondary to BBI items which endorsed behavioural aspects not measured by the ALS-FTD-Q. Good construct validity has been further confirmed when the BBI is compared to an ALS-specific tool. Furthermore, the BBI is a more comprehensive behavioural assessment for ALS, as it measures the whole behavioural spectrum in this condition.

  12. Temporal resolution in individuals with neurological disorders

    PubMed Central

    Rabelo, Camila Maia; Weihing, Jeffrey A; Schochat, Eliane

    2015-01-01

    OBJECTIVE: Temporal processing refers to the ability of the central auditory nervous system to encode and detect subtle changes in acoustic signals. This study aims to investigate the temporal resolution ability of individuals with mesial temporal sclerosis and to determine the sensitivity and specificity of the gaps-in-noise test in identifying this type of lesion. METHOD: This prospective study investigated differences in temporal resolution between 30 individuals with normal hearing and without neurological lesions (G1) and 16 individuals with both normal hearing and mesial temporal sclerosis (G2). Test performances were compared, and the sensitivity and specificity were calculated. RESULTS: There was no difference in gap detection thresholds between the two groups, although G1 revealed better average thresholds than G2 did. The sensitivity and specificity of the gaps-in-noise test for neurological lesions were 68% and 98%, respectively. CONCLUSIONS: Temporal resolution ability is compromised in individuals with neurological lesions caused by mesial temporal sclerosis. The gaps-in-noise test was shown to be a sensitive and specific measure of central auditory dysfunction in these patients. PMID:26375561

  13. Role of androgen ratios in the prediction of the metabolic phenotype in polycystic ovary syndrome.

    PubMed

    Minooee, Sonia; Ramezani Tehrani, Fahimeh; Tohidi, Maryam; Azizi, Fereidoun

    2017-05-01

    To identify the androgen ratio that best predicts insulin resistance and metabolic syndrome among women with polycystic ovary syndrome (PCOS). Data for 180 women with PCOS and 180 healthy controls were extracted from two previous studies in Iran (conducted during 2008-2010 and 2011-2013). The diagnosis of PCOS was based on the Rotterdam criteria. The serum concentration of different androgens was measured. Receiver operating characteristic curve analysis was used to assess the ability of various androgen ratios to predict insulin resistance and metabolic syndrome. Among women with PCOS, the testosterone-to-androstenedione ratio was the best predictor of insulin resistance (sensitivity 0.83, specificity 0.42) and metabolic syndrome (sensitivity 0.85, specificity 0.70). Among healthy controls, the ratio of free androgen index to testosterone was the best predictor of insulin resistance (sensitivity 0.84, specificity 0.33) and metabolic syndrome (sensitivity 0.91, specificity 0.17). The prediction of insulin resistance and metabolic syndrome among women with PCOS was best accomplished with the testosterone-to-androstenedione ratio. © 2017 International Federation of Gynecology and Obstetrics.

  14. Challenges in Routine Implementation and Quality Control of Rapid Diagnostic Tests for Malaria–Rufiji District, Tanzania

    PubMed Central

    McMorrow, Meredith L.; Masanja, M. Irene; Abdulla, Salim M. K.; Kahigwa, Elizeus; Kachur, S. Patrick

    2018-01-01

    Rapid diagnostic tests (RDTs) represent an alternative to microscopy for malaria diagnosis and have shown high sensitivity and specificity in a variety of study settings. Current World Health Organization (WHO) guidelines for quality control of RDTs provide detailed instructions on pre-field testing, but offer little guidance for quality assurance once RDTs are deployed in health facilities. From September 2006 to April 2007, we introduced a histidine-rich protein II (HRP2)-based RDT (Paracheck) for suspected malaria cases five years of age and older in nine health facilities in Rufiji District, Tanzania, to assess sensitivity and specificity of RDTs in routine use at rural health facilities. Thick blood smears were collected for all patients tested with RDTs and stained and read by laboratory personnel in each facility. Thick smears were subsequently reviewed by a reference microscopist to determine RDT sensitivity and specificity. In all nine health facilities, there were significant problems with the quality of staining and microscopy. Sensitivity and specificity of RDTs were difficult to assess given the poor quality of routine blood smear staining. Mean operational sensitivity of RDTs based on reference microscopy was 64.8%, but varied greatly by health facility, range 18.8–85.9%. Sensitivity of RDTs increased with increasing parasite density. Specificity remained high at 87.8% despite relatively poor slide quality. Institution of quality control of RDTs based on poor quality blood smear staining may impede reliable measurement of sensitivity and specificity and undermine confidence in the new diagnostic. There is an urgent need for the development of alternative quality control procedures for rapid diagnostic tests that can be performed at the facility level. PMID:18784230

  15. Improving detection of HIV-associated cognitive impairment: Comparison of the International HIV Dementia Scale and a Brief Screening Battery

    PubMed Central

    de Almeida, Sergio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea Elisa; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K.; Ellis, Ronald J.

    2016-01-01

    Objectives The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia (HAD), but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. Methods 108 participants (including 60 HIV-infected persons), completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible three-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Results Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75% respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared to the gold standard NP battery, were Trail Making Test A, WAIS-III Digit Symbol (DS) and HVLT-R Total Recall (sensitivity 91%, specificity 96%), and DS, BVMT-R Total Recall and Grooved Pegboard Test-Dominant Hand (sensitivity 94%, specificity 91%). Conclusions Both test combinations can be administered in under 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination. PMID:27828876

  16. Improving Detection of HIV-Associated Cognitive Impairment: Comparison of the International HIV Dementia Scale and a Brief Screening Battery.

    PubMed

    de Almeida, Sérgio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea E; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K; Ellis, Ronald J

    2017-03-01

    The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia, but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. A total of 108 participants (including 60 HIV-infected persons) completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible 3-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75%, respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared with the gold standard NP battery, were Trail Making Test A, Wechsler Adult Intelligence Scale III Digit Symbol and Hopkins Verbal Learning Test-Revised Total Recall (sensitivity 91%, specificity 96%), and Digit Symbol, Brief Visuospatial Memory Test-Revised Total Recall and Grooved Pegboard Test-dominant hand (sensitivity 94%, specificity 91%). Both test combinations can be administered in less than 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination.

  17. Parent-child and triadic antecedents of children's social competence: cultural specificity, shared process.

    PubMed

    Feldman, Ruth; Masalha, Shafiq

    2010-03-01

    Guided by theories of cultural participation, the authors examined mother-child, father-child, and triadic interactive behaviors in 141 Israeli and Palestinian couples and their firstborn child at 5 and 33 months as antecedents of children's social competence. Four parent-child measures (parent sensitivity, child social engagement, parental control, dyadic reciprocity) and two family-level measures (cohesion and rigidity) were coded at each age. Children's social competence was observed at child-care locations. Cultural differences were observed for parent sensitivity and child social engagement, and the large cultural differences in sensitivity observed in infancy were attenuated by the toddler age. Interactive behaviors correlated with culture-specific parenting practices, child-rearing goals, and sex-role attitudes. Mother-child reciprocity in infancy and child engagement with father and family-level cohesion at both time points predicted social competence. Maternal sensitivity in infancy facilitated social competence only among Israeli children. Paternal control in toddlerhood interfered with Israeli children's social functioning but contributed to competence among Palestinians. Results underscore the links between early relational experiences and children's adaptation to the social milieu.

  18. Sensitivity and specificity of the empirical lymphocyte genome sensitivity (LGS) assay: implications for improving cancer diagnostics.

    PubMed

    Anderson, Diana; Najafzadeh, Mojgan; Gopalan, Rajendran; Ghaderi, Nader; Scally, Andrew J; Britland, Stephen T; Jacobs, Badie K; Reynolds, P Dominic; Davies, Justin; Wright, Andrew L; Al-Ghazal, Shariff; Sharpe, David; Denyer, Morgan C

    2014-10-01

    Lymphocyte responses from 208 individuals: 20 with melanoma, 34 with colon cancer, and 4 with lung cancer (58), 18 with suspected melanoma, 28 with polyposis, and 10 with COPD (56), and 94 healthy volunteers were examined. The natural logarithm of the Olive tail moment (OTM) was plotted for exposure to UVA through 5 different agar depths (100 cell measurements/depth) and analyzed using a repeated measures regression model. Responses of patients with cancer plateaued after treatment with different UVA intensities, but returned toward control values for healthy volunteers. For precancerous conditions and suspected cancers, intermediate responses occurred. ROC analysis of mean log OTMs, for cancers plus precancerous/suspect conditions vs. controls, cancer vs. precancerous/suspect conditions plus controls, and cancer vs. controls, gave areas under the curve of 0.87, 0.89, and 0.93, respectively (P<0.001). Optimization allowed test sensitivity or specificity to approach 100% with acceptable complementary measures. This modified comet assay could represent a stand-alone test or an adjunct to other investigative procedures for detecting cancer. © FASEB.

  19. Detection of Anatoxin-a(s) in Environmental Samples of Cyanobacteria by Using a Biosensor with Engineered Acetylcholinesterases

    PubMed Central

    Devic, Eric; Li, Dunhai; Dauta, Alain; Henriksen, Peter; Codd, Geoffrey A.; Marty, Jean-Louis; Fournier, Didier

    2002-01-01

    Bioassays are little used to detect individual toxins in the environment because, compared to analytical methods, these assays are still limited by several problems, such as the sensitivity and specificity of detection. We tentatively solved these two drawbacks for detection of anatoxin-a(s) by engineering an acetylcholinesterase to increase its sensitivity and by using a combination of mutants to obtain increased analyte specificity. Anatoxin-a(s), a neurotoxin produced by some freshwater cyanobacteria, was detected by measuring the inhibition of acetylcholinesterase activity. By using mutated enzyme, the sensitivity of detection was brought to below the nanomole-per-liter level. However, anatoxin-a(s) is an organophosphorous compound, as are several synthetic molecules which are widely used as insecticides. The mode of action of these compounds is via inhibition of acetylcholinesterase, which makes the biotest nonspecific. The use of a four-mutant set of acetylcholinesterase variants, two mutants that are sensitive to anatoxin-a(s) and two mutants that are sensitive to the insecticides, allows specific detection of the cyanobacterial neurotoxin. PMID:12147513

  20. Subchronic sleep restriction causes tissue-specific insulin resistance.

    PubMed

    Rao, Madhu N; Neylan, Thomas C; Grunfeld, Carl; Mulligan, Kathleen; Schambelan, Morris; Schwarz, Jean-Marc

    2015-04-01

    Short sleep duration is associated with an increased risk of type 2 diabetes. Subchronic sleep restriction (SR) causes insulin resistance, but the mechanisms and roles of specific tissues are unclear. The purpose of this article was to determine whether subchronic SR altered (1) hepatic insulin sensitivity, (2) peripheral insulin sensitivity, and (3) substrate utilization. This was a randomized crossover study in which 14 subjects underwent 2 admissions separated by a washout period. Each admission had 2 acclimatization nights followed by 5 nights of either SR (4 hours time in bed) or normal sleep (8 hours time in bed). MAIN OUTCOME MEASURE/METHODS: Insulin sensitivity (measured by hyperinsulinemic-euglycemic clamp) and hepatic insulin sensitivity (measured by stable isotope techniques) were measured. In addition, we assayed stress hormone (24-hour urine free cortisol, metanephrine, and normetanephrine), nonesterified fatty acid (NEFA), and β-hydroxybutyrate (β-OH butyrate) levels. Resting energy expenditure (REE) and respiratory quotient (RQ) were measured by indirect calorimetry. Compared to normal sleep, whole-body insulin sensitivity decreased by 25% (P = .008) with SR and peripheral insulin sensitivity decreased by 29% (P = .003). Whereas hepatic insulin sensitivity (endogenous glucose production) did not change significantly, percent gluconeogenesis increased (P = .03). Stress hormones increased modestly (cortisol by 21%, P = .04; metanephrine by 8%, P = .014; normetanephrine by 18%, P = .002). Fasting NEFA and β-OH butyrate levels increased substantially (62% and 55%, respectively). REE did not change (P = 0.98), but RQ decreased (0.81 ± .02 vs 0.75 ± 0.02, P = .045). Subchronic SR causes unique metabolic disturbances characterized by peripheral, but not hepatic, insulin resistance; this was associated with a robust increase in fasting NEFA levels (indicative of increased lipolysis), decreased RQ, and increased β-OH butyrate levels (indicative of whole-body and hepatic fat oxidation, respectively). We postulate that elevated NEFA levels are partially responsible for the decrease in peripheral sensitivity and modulation of hepatic metabolism (ie, increase in gluconeogenesis without increase in endogenous glucose production). Elevated cortisol and metanephrine levels may contribute to insulin resistance by increasing lipolysis and NEFA levels.

  1. Translation, adaptation, and validation of the Sunderland Scale and the Cubbin & Jackson Revised Scale in Portuguese

    PubMed Central

    Sousa, Bruno

    2013-01-01

    Objective To translate into Portuguese and evaluate the measuring properties of the Sunderland Scale and the Cubbin & Jackson Revised Scale, which are instruments for evaluating the risk of developing pressure ulcers during intensive care. Methods This study included the process of translation and adaptation of the scales to the Portuguese language, as well as the validation of these tools. To assess the reliability, Cronbach alpha values of 0.702 to 0.708 were identified for the Sunderland Scale and the Cubbin & Jackson Revised Scale, respectively. The validation criteria (predictive) were performed comparatively with the Braden Scale (gold standard), and the main measurements evaluated were sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve, which were calculated based on cutoff points. Results The Sunderland Scale exhibited 60% sensitivity, 86.7% specificity, 47.4% positive predictive value, 91.5% negative predictive value, and 0.86 for the area under the curve. The Cubbin & Jackson Revised Scale exhibited 73.3% sensitivity, 86.7% specificity, 52.4% positive predictive value, 94.2% negative predictive value, and 0.91 for the area under the curve. The Braden scale exhibited 100% sensitivity, 5.3% specificity, 17.4% positive predictive value, 100% negative predictive value, and 0.72 for the area under the curve. Conclusions Both tools demonstrated reliability and validity for this sample. The Cubbin & Jackson Revised Scale yielded better predictive values for the development of pressure ulcers during intensive care. PMID:23917975

  2. Necrotizing Soft Tissue Infection: Diagnostic Accuracy of Physical Examination, Imaging, and LRINEC Score: A Systematic Review and Meta-Analysis.

    PubMed

    Fernando, Shannon M; Tran, Alexandre; Cheng, Wei; Rochwerg, Bram; Kyeremanteng, Kwadwo; Seely, Andrew J E; Inaba, Kenji; Perry, Jeffrey J

    2018-04-18

    We sought to summarize accuracy of physical examination, imaging, and Laboratory Risk Indicator for Necrotizing Fasciitis (LRINEC) score in diagnosis of necrotizing soft tissue infection (NSTI) in adults with a soft tissue infection clinically concerning for NSTI. NSTI is a life-threatening diagnosis. Delay to diagnosis and surgical management is associated with increased mortality. We searched 6 databases from inception through November 2017. We included English-language studies reporting diagnostic accuracy of testing or LRINEC Score. Outcome was NSTI confirmed by surgery or histopathology. Two reviewers screened all citations and extracted data independently. Summary measures were obtained from the Hierarchical Summary Receiver Operating Characteristic model. From 2,290 citations, we included 23 studies (n = 5982). Of physical examination signs, pooled sensitivity and specificity for fever was 46.0% and 77.0% respectively, for hemorrhagic bullae 25.2% and 95.8%, and for hypotension 21.0% and 97.7%. Computed tomography (CT) had sensitivity of 88.5% and specificity of 93.3%, while plain radiography had sensitivity of 48.9% and specificity of 94.0%. Finally, LRINEC ≥ 6 had sensitivity of 68.2% and specificity of 84.8%, while LRINEC ≥ 8 had sensitivity of 40.8% and specificity of 94.9%. Absence of any 1 physical examination feature (eg, fever or hypotension) is not sufficient to rule-out NSTI. CT is superior to plain radiography. LRINEC had poor sensitivity, and should not be used to rule-out NSTI. Given the poor sensitivity of these tests, a high clinical suspicion warrants early surgical consultation for definitive diagnosis and management.

  3. A new portable sulfide monitor with a zinc-oxide semiconductor sensor for daily use and field study.

    PubMed

    Tanda, Naoko; Washio, Jumpei; Ikawa, Kyoko; Suzuki, Kengo; Koseki, Takeyoshi; Iwakura, Masaki

    2007-07-01

    For measuring oral malodor in daily clinical practice and in field study, we developed and evaluated a highly sensitive portable monitor system. We examined sensitivity and specificity of the sensor for volatile sulfur compounds (VSC) and obstructive gases, such as ethanol, acetone, and acetaldehyde. Each mouth air provided by 46 people was measured by this monitor, gas chromatography (GC), and olfactory panel and compared with each other. Based on the result, we used the monitor for mass health examination of a rural town with standardized measuring. The sensor detected hydrogen sulfide, methyl mercaptan, and dimethyl sulfide with 10-1000 times higher sensitivity than the other gases. The monitor's specificity was significantly improved by a VSC-selective filter. There were significant correlations between VSC concentration by the sulfide monitor and by GC, and by organoleptic score. Thirty-six percent of 969 examinees had oral malodor in a rural town. Seventy-eight percent of 969 examinees were motivated to take care of their oral condition by oral malodor measuring with the monitor. The portable sulfide monitor was useful to promote oral health care not only in clinics, but also in field study. The simple and quick operation system and the standardized measuring make it one of parameters of oral condition.

  4. Determining sensitivity/specificity of virtual reality-based neuropsychological tool for detecting residual abnormalities following sport-related concussion.

    PubMed

    Teel, Elizabeth; Gay, Michael; Johnson, Brian; Slobounov, Semyon

    2016-05-01

    Computer-based neuropsychological (NP) evaluation is an effective clinical tool used to assess cognitive function which complements the clinical diagnosis of a concussion. However, some researchers and clinicians argue its lack of ecological validity places limitations on externalizing results to a sensory rich athletic environment. Virtual reality-based NP assessment offers clinical advantages using an immersive environment and evaluating domains not typically assessed by traditional NP assessments. The sensitivity and specificity of detecting lingering cognitive abnormalities was examined on components of a virtual reality-based NP assessment battery to cohort affiliation (concussed vs. controls). Data were retrospectively gathered on 128 controls (no concussion) and 24 concussed college-age athletes on measures of spatial navigation, whole body reaction, attention, and balance in a virtual environment. Concussed athletes were tested within 10 days (M = 8.33, SD = 1.06) of concussion and were clinically asymptomatic at the time of testing. A priori alpha level was set at 0.05 for all tests. Spatial navigation (sensitivity 95.8%/specificity 91.4%, d = 1.89), whole body reaction time (sensitivity 95.2%/specificity 89.1%, d = 1.50) and combined virtual reality modules (sensitivity 95.8%,/specificity 96.1%, d = 3.59) produced high sensitivity/specificity values when determining performance-based variability between groups. Use of a virtual reality-based NP platform can detect lingering cognitive abnormalities resulting from concussion in clinically asymptomatic participants. Virtual reality NP platforms may compliment the traditional concussion assessment battery by providing novel information. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Evaluation of phenotypic detection methods for metallo-β-lactamases (MBLs) in clinical isolates of Pseudomonas aeruginosa.

    PubMed

    Peter, S; Lacher, A; Marschal, M; Hölzl, F; Buhl, M; Autenrieth, I; Kaase, M; Willmann, M

    2014-07-01

    Metallo-beta-lactamase (MBL) production in Pseudomonas aeruginosa is a growing issue across the globe. Fast and reliable diagnostic tools are needed for appropriate implementation of infection control measures. In this study we evaluated the performance of three commercial combined disk tests, two EDTA based in-house combined disk tests and the Carba NP test in comparison to molecular detection of MBL genes on 133 meropenem non-susceptible non-duplicate P. aeruginosa clinical isolates. The meropenem/DPA based commercial KPC + MBL-confirm ID kit (Rosco Diagnostica, Denmark) and the MASTDISCS™ ID carbapenemase (Enterobacteriaceae) detection disc set (MAST Diagnostics, UK) showed sensitivities of 31.1 % and 28.8 % and specificities of 69.3 % and 79.6 %, respectively. The total MBL confirm kit (Rosco Diagnostica, Denmark) contains imipenem/DPA and imipenem/EDTA combination disks. Evaluation of the single disk combinations revealed 84.4 % sensitivity and 81.8 % specificity for the imipenem/DPA assay and 86.7 % sensitivity and 51.1 % specificity for the imipenem/EDTA test. Applying both tests simultaneously resulted in a slightly higher sensitivity of 88.9 % but a lower specificity of 48.9 % when compared to the single tests alone. The Carba NP test showed 93.3 % sensitivity and 96.6 % specificity. All phenotypic combined disk tests lacked either sensitivity or specificity for the detection of MBL in P. aeruginosa. The Carba NP test showed excellent test properties, but suffers from drawbacks in handling and high costs. The optimal diagnostic approach needs to be chosen depending on the epidemiological situation, laboratory resources and availability of molecular confirmation tests.

  6. Comparison of Heidelberg Retina Tomograph-3 glaucoma probability score and Moorfields regression analysis of optic nerve head in glaucoma patients and healthy individuals.

    PubMed

    Caglar, Çagatay; Gul, Adem; Batur, Muhammed; Yasar, Tekin

    2017-01-01

    To compare the sensitivity and specificity of Moorfields regression analysis (MRA) and glaucoma probability score (GPS) between healthy and glaucomatous eyes with Heidelberg Retinal Tomograph 3 (HRT-3). The study included 120 eyes of 75 glaucoma patients and 138 eyes of 73 normal subjects, for a total of 258 eyes of 148 individuals. All measurements were performed with the HRT-3. Diagnostic test criteria (sensitivity, specificity, etc.) were used to evaluate how efficiently GPS and MRA algorithms in the HRT-3 discriminated between the glaucoma and control groups. The GPS showed 88 % sensitivity and 66 % specificity, whereas MRA had 71.5 % sensitivity and 82.5 % specificity. There was 71 % agreement between the final results of MRA and GPS in the glaucoma group. Excluding borderline patients from both analyses resulted in 91.6 % agreement. In the control group the level of agreement between MRA and GPS was 64 % including borderline patients and 84.1 % after excluding borderline patients. The accuracy rate is 92 % for MRA and 91 % for GPS in the glaucoma group excluding borderline patients. The difference was nor statistically different. In both cases, agreement was higher between MRA and GPS in the glaucoma group. We found that both sensitivity and specificity increased with disc size for MRA, while the sensitivity increased and specificity decreased with larger disc sizes for GPS. HRT is able to quantify and clearly reveal structural changes in the ONH and RNFL in glaucoma.

  7. 49 CFR 15.5 - Sensitive security information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... sources and methods used to gather or develop threat information, including threats against cyber infrastructure. (8) Security measures. Specific details of aviation or maritime transportation security measures... infrastructure asset information. Any list identifying systems or assets, whether physical or virtual, so vital...

  8. 49 CFR 15.5 - Sensitive security information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... sources and methods used to gather or develop threat information, including threats against cyber infrastructure. (8) Security measures. Specific details of aviation or maritime transportation security measures... infrastructure asset information. Any list identifying systems or assets, whether physical or virtual, so vital...

  9. 49 CFR 15.5 - Sensitive security information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... sources and methods used to gather or develop threat information, including threats against cyber infrastructure. (8) Security measures. Specific details of aviation or maritime transportation security measures... infrastructure asset information. Any list identifying systems or assets, whether physical or virtual, so vital...

  10. 49 CFR 15.5 - Sensitive security information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... sources and methods used to gather or develop threat information, including threats against cyber infrastructure. (8) Security measures. Specific details of aviation or maritime transportation security measures... infrastructure asset information. Any list identifying systems or assets, whether physical or virtual, so vital...

  11. A sensitive ELISA for measuring the adhesion of leukocytic cells to human endothelial cells.

    PubMed

    Krakauer, T

    1994-12-28

    A new, sensitive ELISA using monoclonal antibodies reactive with surface molecules specific for various leukocytes was devised to measure the attachment of these cells to cultured monolayers of human umbilical vein endothelial cells. Preparations of peripheral blood mononuclear cells, a human monocytic cell line (THP-1) and a human lymphoblastic T cell line (MOLT-4) were used to test the sensitivity of this method and compare it with the conventional 51Cr-radiolabeled cell assay. The extent of adhesion to endothelial cells was assayed by measuring the optical density produced by a complex of peroxidase-labeled streptavidin, biotin-conjugated F(ab')2 anti-mouse Ig and monoclonal antibody on fixed leukocytic cells that had adhered to endothelial cells. This method is fast and sensitive, eliminates the use of radioisotopes, and, because the detection uses a specific marker on the cell of interest, can be used in preparations of unseparated mixtures of cells. As this is a microassay, using relatively small number of cells and reagents, the methodology can be applied to screen a large number of therapeutic agents that may regulate adhesion. Using this method, the anti-inflammatory corticosteroid, dexamethasone, was found to inhibit the adhesion of THP-1 and MOLT-4 cells to cytokine-activated endothelial cells.

  12. Simultaneous velocity and pressure quantification using pressure-sensitive flow tracers in air

    NASA Astrophysics Data System (ADS)

    Zhang, Peng; Peterson, Sean; Porfiri, Maurizio

    2017-11-01

    Particle-based measurement techniques for assessing the velocity field of a fluid have advanced rapidly over the past two decades. Full-field pressure measurement techniques have remained elusive, however. In this work, we aim to demonstrate the possibility of direct simultaneous planar velocity and pressure measurement of a high speed aerodynamic flow by employing novel pressure-sensitive tracer particles for particle image velocimetry (PIV). Specifically, the velocity and pressure variations of an airflow through a converging-diverging channel are studied. Polystyrene microparticles embedded with a pressure-sensitive phosphorescent dye-platinum octaethylporphyrin (PtOEP)-are used as seeding particles. Due to the oxygen quenching effect, the emission lifetime of PtOEP is highly sensitive to the oxygen concentration, that is, the partial pressure of oxygen, in the air. Since the partial pressure of oxygen is linearly proportional to the air pressure, we can determine the air pressure through the phosphorescence emission lifetime of the dye. The velocity field is instead obtained using traditional PIV methods. The particles have a pressure resolution on the order of 1 kPa, which may be improved by optimizing the particle size and dye concentration to suit specific flow scenarios. This work was supported by the National Science Foundation under Grant Number CBET-1332204.

  13. Chemokines additional to IFN-γ can be used to differentiate among Mycobacterium tuberculosis infection possibilities and provide evidence of an early clearance phenotype.

    PubMed

    Nonghanphithak, Ditthawat; Reechaipichitkul, Wipa; Namwat, Wises; Naranbhai, Vivek; Faksri, Kiatichai

    2017-07-01

    Current diagnostic tests for tuberculosis (TB) remain limited in their ability to discriminate between active TB (ATB) and latent TB infection (LTBI). Early clearance (EC) of TB by individuals exposed to Mycobacterium tuberculosis is a debated phenomenon for which evidence is lacking. We measured and compared secreted chemokines in the plasma fraction from 48 ATB, 38 LTBI, 162 presumed EC and 39 healthy controls (HC) using the QuantiFERON ® -TB Gold In-Tube assay. Single chemokine markers were limited in their ability to discriminate between ATB and LTBI: IFN-γ showed 16.7% sensitivity; CCL2 showed moderate sensitivity (70.8%) and specificity (74.4%); CXCL10 showed high sensitivity (87.5%) and specificity (78.9%). Compared to IFN-γ alone, IFN-γ combined with CXCL10 significantly improved (p < 0.001) the sensitivity and specificity to discriminate between ATB and HC (97.9% sensitivity and 94.9% specificity) and between ATB and LTBI (89.6% sensitivity and 71.1% specificity). Levels of CCL2 were very significantly lower (p < 0.0001) in EC compared to HC groups and hence CCL2 is a useful marker for EC. This study demonstrated the potential application of profiling using multiple chemokines for differentiating among the various M. tuberculosis infection possibilities. We also present evidence to support the EC phenomenon based on the decrease of CCL2 levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Accidental falls in hospital inpatients: evaluation of sensitivity and specificity of two risk assessment tools.

    PubMed

    Lovallo, Carmela; Rolandi, Stefano; Rossetti, Anna Maria; Lusignani, Maura

    2010-03-01

    This paper is a report of a study comparing the effectiveness of two falls risk assessment tools (Conley Scale and Hendrich Risk Model) by using them simultaneously with the same sample of hospital inpatients. Different risk assessment tools are available in literature. However, neither recent critical reviews nor international guidelines on fall prevention have identified tools that can be generalized to all categories of hospitalized patients. A prospective observational study was carried out in acute medical, surgical wards and rehabilitation units. From October 2007 to January 2008, 1148 patients were assessed with both instruments, subsequently noting the occurrence of falls. The sensitivity, specificity, positive and negative predictive values, and Receiver Operating Characteristics curves were calculated. The number of patients correctly identified with the Conley Scale (n = 41) was higher than with the Hendrich Model (n = 27). The Conley Scale gave sensitivity and specificity values of 69.49% and 61% respectively. The Hendrich Model gave a sensitivity value of 45.76% and a specificity value of 71%. Positive and negative predictive values were comparable. The Conley Scale is indicated for use in the medical sector, on the strength of its high sensitivity. However, since its specificity is very low, it is deemed useful to submit individual patients giving positive results to more in-depth clinical evaluation in order to decide whether preventive measures need to be taken. In surgical sectors, the low sensitivity values given by both scales suggest that further studies are warranted.

  15. Sensitivity and Specificity of 2 Autism Screeners Among Referred Children Between 16 and 48 Months of Age.

    PubMed

    Salisbury, Louisa A; Nyce, Jonathan D; Hannum, Charles D; Sheldrick, R Christopher; Perrin, Ellen C

    2018-04-01

    Autism screening is recommended by the American Academy of Pediatrics and the Centers for Disease Control and Prevention at ages 18 and 24 months. Popular screening tests have been validated for the age range of 16 to 30 months. However, only a minority of children with autism spectrum disorder (ASD) are identified by age 3 years, and many are not identified until after they enter school. Thus, we aimed to measure the sensitivity and specificity of 2 available screening tests for ASDs in children older than 30 months. We assessed the sensitivity and specificity of 2 ASD screening tools administered to parents of children who were referred to a developmental clinic between the ages of 16 and 48 months: the Modified Checklist for Autism in Toddlers (M-CHAT) and the Parent's Observations of Social Interactions (POSI), which is a component of a comprehensive screening instrument called, the Survey of Well-being of Young Children. Both the M-CHAT and the POSI had acceptable sensitivity (≥75%) among children across the age range studied. Their specificity was limited by the fact that the study was conducted in a developmental referral clinic. Two readily available screening tools, the POSI and the M-CHAT, have acceptable sensitivity in evaluating risk for autism in children at least to age 48 months. Further research should investigate their sensitivity and specificity when used in primary care settings.

  16. Immune suppression with supraoptimal doses of antigen in contact sensitivity. I. Demonstration of suppressor cells and their sensitivity to cyclophosphamide.

    PubMed

    Sy, M S; Miller, S D; Claman, H N

    1977-07-01

    Immunologic suppression was induced in a mouse model of contact sensitization to DNFB by using supraoptimal doses of antigen. In these studies, in vivo measurement of ear swelling as an indication of immunologic responsiveness correlated well with measurement of in vitro antigen-induced cell proliferation. This unresponsiveness was specific, since supraoptimal doses of DNFB did not interfere with the development of contact sensitivity to another contactant, oxazolone. The decrease in responsiveness is a form of active suppression, as lymphoid cells from supraoptimally sensitized donors transferred suppression to normal recipients. Furthermore, pretreatment with cyclophosphamide (Cy) reversed the suppression seen in supraoptimally sensitized animals but had no effect on the optimal sensitization regimen. These results indicate that supraoptimal doses of contactants can activate suppressor cells and that precursors of these cells are sensitive to Cy. Such suppressors regenerate within 7 to 14 days after Cy treatment. The ability of Cy pretreatment to affect supraoptimal sensitization without affecting optimal sensitization confirms other reports indicating that the observed results of Cy treatment depend critically upon the dose of antigen used.

  17. Promoter methylation of MCAM, ERα and ERβ in serum of early stage prostate cancer patients.

    PubMed

    Brait, Mariana; Banerjee, Mithu; Maldonado, Leonel; Ooki, Akira; Loyo, Myriam; Guida, Elisa; Izumchenko, Evgeny; Mangold, Leslie; Humphreys, Elizabeth; Rosenbaum, Eli; Partin, Alan; Sidransky, David; Hoque, Mohammad Obaidul

    2017-02-28

    Prostate cancer (PC) is the second most common cancer among men worldwide. Currently, the most common non-invasive approach for screening and risk assessment of PC is measuring the level of serum prostate-specific antigen (PSA). However, the sensitivity of PSA is 42.8 % and specificity is 41.1%. As a result, the serum PSA test leads to numerous unneeded biopsies. Therefore, a rigorous search for biomarkers for early detection of PC is ongoing. In this study, we aim to assess a panel of epigenetic markers in an intend to develop an early detection test for PC. The sensitivity and specificity of hypermethylation of MCAM was 66% and 73% respectively which is an improvement from the sensitivity and specificity of PSA. Considering a combination marker panel of MCAM, ERα and ERβ increased the sensitivity to 75% and the specificity became 70% for the minimally invasive early detection test of PC. Sixteen primary matched tumor and serum were analyzed by quantitative methylation specific PCR (QMSP) to determine analytical and clinical sensitivity of the genes tested (SSBP2, MCAM, ERα, ERβ, APC, CCND2, MGMT, GSTP1, p16 and RARβ2). Additionally, serum samples from eighty four cases of PC, thirty controls and seven cases diagnosed as high grade Prostatic Intraepithelial Neoplasia (HGPIN) were analyzed. Promoter methylation of MCAM, ERα and ERβ have a potential to be utilized as biomarker for the early detection of prostate PC as their sensitivity and specificity seem to be better than serum PSA in our cohort of samples. After robust validation in a larger prospective cohort, our findings may reduce the numbers of unwarranted prostate biopsies.

  18. Asymmetric Mach-Zehnder Interferometer Based Biosensors for Aflatoxin M1 Detection.

    PubMed

    Chalyan, Tatevik; Guider, Romain; Pasquardini, Laura; Zanetti, Manuela; Falke, Floris; Schreuder, Erik; Heideman, Rene G; Pederzolli, Cecilia; Pavesi, Lorenzo

    2016-01-06

    In this work, we present a study of Aflatoxin M1 detection by photonic biosensors based on Si₃N₄ Asymmetric Mach-Zehnder Interferometer (aMZI) functionalized with antibodies fragments (Fab'). We measured a best volumetric sensitivity of 10⁴ rad/RIU, leading to a Limit of Detection below 5 × 10(-7) RIU. On sensors functionalized with Fab', we performed specific and non-specific sensing measurements at various toxin concentrations. Reproducibility of the measurements and re-usability of the sensor were also investigated.

  19. Perspective: Optical measurement of feature dimensions and shapes by scatterometry

    NASA Astrophysics Data System (ADS)

    Diebold, Alain C.; Antonelli, Andy; Keller, Nick

    2018-05-01

    The use of optical scattering to measure feature shape and dimensions, scatterometry, is now routine during semiconductor manufacturing. Scatterometry iteratively improves an optical model structure using simulations that are compared to experimental data from an ellipsometer. These simulations are done using the rigorous coupled wave analysis for solving Maxwell's equations. In this article, we describe the Mueller matrix spectroscopic ellipsometry based scatterometry. Next, the rigorous coupled wave analysis for Maxwell's equations is presented. Following this, several example measurements are described as they apply to specific process steps in the fabrication of gate-all-around (GAA) transistor structures. First, simulations of measurement sensitivity for the inner spacer etch back step of horizontal GAA transistor processing are described. Next, the simulated metrology sensitivity for sacrificial (dummy) amorphous silicon etch back step of vertical GAA transistor processing is discussed. Finally, we present the application of plasmonically active test structures for improving the sensitivity of the measurement of metal linewidths.

  20. Association of anti-cyclic citrullinated peptide antibodies, anti-citrullin antibodies, and IgM and IgA rheumatoid factors with serological parameters of disease activity in rheumatoid arthritis.

    PubMed

    Greiner, Alexander; Plischke, Herbert; Kellner, Herbert; Gruber, Rudolf

    2005-06-01

    We evaluated the association of anti-cyclic citrullinated peptide (CCP) antibody titers with serological markers of disease activity. We also compared three different anti-CCP antibody ELISAs with an anti-citrullin ELISA and the IgM and the IgA rheumatoid factor (RF) in their performance of discriminating between rheumatoid arthritis (RA) and other rheumatic diseases. Sera from 333 consecutive patients of the Rheumaeinheit der Medizinischen Poliklinik Munchen, an outpatient clinic for rheumatic diseases, were collected and tested. Anti-CCP antibodies were assayed with three different commercially available ELISAs. Antifilaggrin antibodies were tested with a commercially available ELISA using in vitro deiminated recombinant rat filaggrin. IgA-RF was analyzed with an ELISA, whereas IgM-RF was measured by latex-enhanced turbidimetry. Rheumatoid arthritis (RA) was diagnosed in 87 patients according to the revised classification criteria of the American College of Rheumatology (ACR), probable RA was diagnosed in 23 patients in an early phase not (yet) fulfilling the ACR criteria, and 223 patients had other rheumatic diseases. Differences in sensitivity and specificity were calculated using McNemar's test. A measure of agreement (kappa statistic) was used to examine whether the tests tended to identify the same patients as positive or negative. Correlations between CCP titers and other tests were analyzed by Spearman nonparametric rank correlation. No significant differences in sensitivity and specificity were found between the tested CCP assays (80.0-80.9% and 97.3-98.1%, respectively). All three CCP tests were slightly but not significantly more sensitive and specific than the anti-citrullin assay (77% and 92%, respectively), comparably sensitive but significantly more specific compared with the IgM-RF (86% and 82%, respectively), and significantly more sensitive but comparably specific compared with the IgA-RF (63% and 94.4%, respectively) in detecting the patients with RA. There was no significant correlation between anti-CCP, anti-citrullin, or IgM-RF or IgA-RF antibody titers and C-reactive protein, erythrocyte sedimentation rate, or white blood cell count. A weak but significant linear correlation was found between anti-CCP titers and IgM-RF titers (r = 0.2, P = 0.03). We could not find a significant difference between the three tested anti-CCP assays and the anti-citrullin test in terms of sensitivity and specificity. Compared with the IgM-RF, all the anti-CCP assays were superior in specificity and comparable in sensitivity. Compared with the IgA-RF, they were more sensitive and comparably specific in the discrimination of patients with RA from other rheumatic diseases. No correlation of any tested autoantibody titer with serological parameters of inflammation was found.

  1. Radiological Evaluation of Strategic Structures in Patients with Mild Cognitive Impairment and Early Alzheimer's Disease.

    PubMed

    Nesteruk, Tomasz; Nesteruk, Marta; Styczyńska, Maria; Barcikowska-Kotowicz, Maria; Walecki, Jerzy

    2016-01-01

    The aim of the study was to evaluate the diagnostic value of two measurement techniques in patients with cognitive impairment - automated volumetry of the hippocampus, entorhinal cortex, parahippocampal gyrus, posterior cingulate gyrus, cortex of the temporal lobes and corpus callosum, and fractional anisotropy (FA) index measurement of the corpus callosum using diffusion tensor imaging. A total number of 96 patients underwent magnetic resonance imaging study of the brain - 33 healthy controls (HC), 33 patients with diagnosed mild cognitive impairment (MCI) and 30 patients with Alzheimer's disease (AD) in early stage. The severity of the dementia was evaluated with neuropsychological test battery. The volumetric measurements were performed automatically using FreeSurfer imaging software. The measurements of FA index were performed manually using ROI (region of interest) tool. The volumetric measurement of the temporal lobe cortex had the highest correct classification rate (68.7%), whereas the lowest was achieved with FA index measurement of the corpus callosum (51%). The highest sensitivity and specificity in discriminating between the patients with MCI vs. early AD was achieved with the volumetric measurement of the corpus callosum - the values were 73% and 71%, respectively, and the correct classification rate was 72%. The highest sensitivity and specificity in discriminating between HC and the patients with early AD was achieved with the volumetric measurement of the entorhinal cortex - the values were 94% and 100%, respectively, and the correct classification rate was 97%. The highest sensitivity and specificity in discriminating between HC and the patients with MCI was achieved with the volumetric measurement of the temporal lobe cortex - the values were 90% and 93%, respectively, and the correct classification rate was 92%. The diagnostic value varied depending on the measurement technique. The volumetric measurement of the atrophy proved to be the best imaging biomarker, which allowed the distinction between the groups of patients. The volumetric assessment of the corpus callosum proved to be a useful tool in discriminating between the patients with MCI vs. early AD.

  2. The sensitivity, specificity and efficiency values of some serological tests used in the diagnosis of paracoccidioidomycosis.

    PubMed

    Del Negro, G M; Garcia, N M; Rodrigues, E G; Cano, M I; de Aguiar, M S; Lírio, V de S; Lacaz, C da S

    1991-01-01

    This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e., a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO. The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.

  3. Porous silicon ring resonator for compact, high sensitivity biosensing applications

    DOE PAGES

    Rodriguez, Gilberto A.; Hu, Shuren; Weiss, Sharon M.

    2015-01-01

    A ring resonator is patterned on a porous silicon slab waveguide to produce a compact, high quality factor biosensor with a large internal surface area available for enhanced recognition of biological and chemical molecules. The porous nature of the ring resonator allows molecules to directly interact with the guided mode. Quality factors near 10,000 were measured for porous silicon ring resonators with a radius of 25 μm. A bulk detection sensitivity of 380 nm/RIU was measured upon exposure to salt water solutions. Specific detection of nucleic acid molecules was demonstrated with a surface detection sensitivity of 4 pm/nM.

  4. 49 CFR 1520.5 - Sensitive security information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., including threats against cyber infrastructure. (8) Security measures. Specific details of aviation...) Critical aviation, maritime, or rail infrastructure asset information. Any list identifying systems or...

  5. 49 CFR 1520.5 - Sensitive security information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., including threats against cyber infrastructure. (8) Security measures. Specific details of aviation...) Critical aviation, maritime, or rail infrastructure asset information. Any list identifying systems or...

  6. 49 CFR 1520.5 - Sensitive security information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., including threats against cyber infrastructure. (8) Security measures. Specific details of aviation...) Critical aviation, maritime, or rail infrastructure asset information. Any list identifying systems or...

  7. 49 CFR 1520.5 - Sensitive security information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., including threats against cyber infrastructure. (8) Security measures. Specific details of aviation...) Critical aviation, maritime, or rail infrastructure asset information. Any list identifying systems or...

  8. Clinical utility of the mBIAS and NSI validity-10 to detect symptom over-reporting following mild TBI: A multicenter investigation with military service members.

    PubMed

    Armistead-Jehle, Patrick; Cooper, Douglas B; Grills, Chad E; Cole, Wesley R; Lippa, Sara M; Stegman, Robert L; Lange, Rael T

    2018-04-01

    Self-report measures are commonly relied upon in military healthcare environments to assess service members following a mild traumatic brain injury (mTBI). However, such instruments are susceptible to over-reporting and rarely include validity scales. This study evaluated the utility of the mild Brain Injury Atypical Symptoms scale (mBIAS) and the Neurobehavioral Symptom Inventory Validity-10 scale to detect symptom over-reporting. A total of 359 service members with a reported history of mTBI were separated into two symptom reporting groups based on MMPI-2-RF validity scales (i.e., non-over-reporting versus symptom over-reporting). The clinical utility of the mBIAS and Validity-10 as diagnostic indicators and screens of symptom over-reporting were evaluated by calculating sensitivity, specificity, positive test rate, positive predictive power (PPP), and negative predictive power (NPP) values. An mBIAS cut score of ≥10 was optimal as a diagnostic indicator, which resulted in high specificity and PPP; however, sensitivity was low. The utility of the mBIAS as a screening instrument was limited. A Validity-10 cut score of ≥33 was optimal as a diagnostic indicator. This resulted in very high specificity and PPP, but low sensitivity. A Validity-10 cut score of ≥7 was considered optimal as a screener, which resulted in moderate sensitivity, specificity, NPP, but relatively low PPP. Owing to low sensitivity, the current data suggests that both the mBIAS and Validity-10 are insufficient as stand-alone measures of symptom over-reporting. However, Validity-10 scores above the identified cut-off of ≥7should be taken as an indication that further evaluation to rule out symptom over-reporting is necessary.

  9. Adaptation and initial validation of the Patient Health Questionnaire - 9 (PHQ-9) and the Generalized Anxiety Disorder - 7 Questionnaire (GAD-7) in an Arabic speaking Lebanese psychiatric outpatient sample.

    PubMed

    Sawaya, Helen; Atoui, Mia; Hamadeh, Aya; Zeinoun, Pia; Nahas, Ziad

    2016-05-30

    The Patient Health Questionnaire - 9 (PHQ-9) and Generalized Anxiety Disorder - 7 (GAD-7) are short screening measures used in medical and community settings to assess depression and anxiety severity. The aim of this study is to translate the screening tools into Arabic and evaluate their psychometric properties in an Arabic-speaking Lebanese psychiatric outpatient sample. The patients completed the questionnaires, among others, prior to being evaluated by a clinical psychiatrist or psychologist. The scales' internal consistency and factor structure were measured and convergent and discriminant validity were established by comparing the scores with clinical diagnoses and the Psychiatric Diagnostic Screening Questionnaire - MDD subset (PDSQ - MDD). Results showed that the PHQ-9 and GAD-7 are reliable screening tools for depression and anxiety and their factor structures replicated those reported in the literature. Sensitivity and specificity analyses showed that the PHQ-9 is sensitive but not specific at capturing depressive symptoms when compared to clinician diagnoses whereas the GAD-7 was neither sensitive nor specific at capturing anxiety symptoms. The implications of these findings are discussed in reference to the scales themselves and the cultural specificity of the Lebanese population. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Psychometric Evaluation of the Substance Use Risk Profile Scale (SURPS) in an Inpatient Sample of Substance Users Using Cue-Reactivity Methodology

    PubMed Central

    Schlauch, Robert C.; Crane, Cory A.; Houston, Rebecca J.; Molnar, Danielle S.; Schlienz, Nicolas J.; Lang, Alan R.

    2015-01-01

    The current project sought to examine the psychometric properties of a personality based measure (Substance Use Risk Profile Scale; SURPS: introversion-hopelessness, anxiety sensitivity, impulsivity, and sensation seeking) designed to differentially predict substance use preferences and patterns by matching primary personality-based motives for use to the specific effects of various psychoactive substances. Specifically, we sought to validate the SURPS in a clinical sample of substance users using cue reactivity methodology to assess current inclinations to consume a wide range of psychoactive substances. Using confirmatory factor analysis and correlational analyses, the SURPS demonstrated good psychometric properties and construct validity. Further, impulsivity and sensation-seeking were associated with use of multiple substances but could be differentiated by motives for use and susceptibility to the reinforcing effects of stimulants (i.e., impulsivity) and alcohol (i.e. sensation-seeking). In contrast, introversion-hopelessness and anxiety sensitivity demonstrated a pattern of use more focused on reducing negative affect, but were not differentiated based on specific patterns of use. Taken together, results suggests that among those receiving inpatient treatment for substance use disorders, the SURPS is a valid instrument for measuring four distinct personality dimensions that may be sensitive to motivational susceptibilities to specific patterns of alcohol and drug use. PMID:26052180

  11. Musical ability and non-native speech-sound processing are linked through sensitivity to pitch and spectral information.

    PubMed

    Kempe, Vera; Bublitz, Dennis; Brooks, Patricia J

    2015-05-01

    Is the observed link between musical ability and non-native speech-sound processing due to enhanced sensitivity to acoustic features underlying both musical and linguistic processing? To address this question, native English speakers (N = 118) discriminated Norwegian tonal contrasts and Norwegian vowels. Short tones differing in temporal, pitch, and spectral characteristics were used to measure sensitivity to the various acoustic features implicated in musical and speech processing. Musical ability was measured using Gordon's Advanced Measures of Musical Audiation. Results showed that sensitivity to specific acoustic features played a role in non-native speech-sound processing: Controlling for non-verbal intelligence, prior foreign language-learning experience, and sex, sensitivity to pitch and spectral information partially mediated the link between musical ability and discrimination of non-native vowels and lexical tones. The findings suggest that while sensitivity to certain acoustic features partially mediates the relationship between musical ability and non-native speech-sound processing, complex tests of musical ability also tap into other shared mechanisms. © 2014 The British Psychological Society.

  12. Sensitivity to disgust, stigma, and adjustment to life with a colostomy

    PubMed Central

    Smith, Dylan M.; Loewenstein, George; Rozin, Paul; Sherriff, Ryan L.; Ubel, Peter A.

    2007-01-01

    We examined whether trait disgust sensitivity predicts well-being in colostomy patients, and whether disgust predicts stigmatizing attitudes about colostomy in non-patients. 195 patients with a colostomy returned a mailed survey including measures of disgust sensitivity, life satisfaction, mood, and feelings of being stigmatized. We also conducted an internet-survey of a non-patient sample (n = 523). In the patient sample, we observed negative correlations between a bowel-specific measure of disgust sensitivity and life satisfaction (r = −.34, p<.01), and colostomy adjustment ( r = −.42, p<.01), and a positive correlation with feeling stigmatized because of the colostomy (r = .54, p<.01). Correlations between a general trait disgust measure and these outcomes were more modest. A structural equation model indicated that colostomy patients who had high disgust sensitivity felt more stigmatized, and this was in turn strongly related to lower life satisfaction. Concordantly, in the non-patient sample we observed that disgust sensitivity was a significant, positive predictor of wanting less contact with colostomy patients (r = .22, p < .01). PMID:17940585

  13. Preschool Neuropsychological Measures as Predictors of Later Attention Deficit Hyperactivity Disorder

    PubMed Central

    Breaux, Rosanna P.; Griffith, Shayl F.; Harvey, Elizabeth A.

    2016-01-01

    The present study examined preschool neuropsychological measures as predictors of school-age attention deficit hyperactivity disorder (ADHD). Participants included 168 children (91 males) who completed neuropsychological measures at ages 3 and 4, and who were evaluated for ADHD and oppositional defiant disorder at age 6. The Conners’ Kiddie Continuous Performance Test (K-CPT), NEPSY Statue subtest, and a delay aversion task significantly distinguished at-risk children who later did and did not meet criteria for ADHD, with poor to fair overall predictive power, specificity, and sensitivity. However, only the K-CPT ADHD Confidence Index and battery added incremental predictive validity beyond early ADHD symptoms. This battery approach, which required impairment on at least 2 of the 3 significant measures, yielded fair overall predictive power, specificity, and sensitivity, and correctly classified 67% of children. In addition, there was some support for the specificity hypothesis, with evidence that cool executive function measures (K-CPT and Statue subtest) tended to predict inattentive symptoms. These findings suggest that neuropsychological deficits are evident by preschool-age in children with ADHD, but neuropsychological tests may still misclassify approximately one-third of children if used alone. Thus, neuropsychological measures may be a useful component of early ADHD assessments, but should be used with caution and in combination with other assessment methods. PMID:26936037

  14. Height velocity and IGF-I assessment in the diagnosis of childhood onset GH insufficiency: do we still need a second GH stimulation test?

    PubMed

    Cianfarani, Stefano; Tondinelli, Tiziana; Spadoni, Gian Luigi; Scirè, Giuseppe; Boemi, Sergio; Boscherini, Brunetto

    2002-08-01

    The diagnosis of GH insufficiency (GHI) in childhood is not straightforward. Our aim was to test the sensitivity and specificity of height velocity (HV), IGF-I, IGFBP-3 and GH stimulation tests alone or in combination in the diagnosis of GHI. A retrospective review of patients with GHI and idiopathic short stature (ISS) diagnosed in our centre and followed up to the completion of linear growth. Thirty-three GHI children and 56 children with ISS were evaluated. GHI diagnosis was based on fulfilment of anthropometric, endocrine and neuroradiological criteria: stature < or = -2 z-score, delayed bone age (at least 1 year), GH peak response to at least two different provocative tests < 10 micro g/l (20 mU/l), brain MRI positive for hypothalamus-pituitary abnormalities, catch-up growth during the first year of GH replacement therapy > or = 75th centile, peak GH response to a third provocative test after growth completion < 10 micro g/l (20 mU/l). Children with anthropometry resembling that of GHI but with peak GH responses > 10 micro g/l (20 mU/l) were diagnosed as ISS. All subjects underwent standard anthropometry. GH secretory status was assessed by clonidine, arginine and GHRH plus arginine stimulation tests. IGF-I and IGFBP-3 circulating levels were measured by immunoradiometric assay (IRMA). The following cut-off values were chosen to discriminate between GHI and nonGHI short children: HV < 25th centile over the 6-12 months prior to the initiation of GH therapy, peak GH responses < 10 or < 7 micro g/l (< 20 or < 14 mU/l) and IGF-I and IGFBP-3-values < -1.9 z-score. Sensitivity (true positive ratio) and specificity (true negative ratio) were evaluated. Taking 10 micro g/l (20 mU/l) as the cut-off value, sensitivity was 100% and specificity 57% for GH provocative tests, whereas taking 7 as the cut-off value, sensitivity was 66% and specificity rose to 78%. Sensitivity was 73% for IGF-I and 30% for IGFBP-3 measurement, whilst specificity was 95% for IGF-I and 98% for IGFBP-3 evaluation. HV assessment revealed a sensitivity of 82% and a specificity of 43%. When HV and IGF-I evaluations were used in combination, sensitivity reached 95% and specificity 96%. When both HV and IGF-I are normal (26% of our subjects) GHI may be ruled out, whereas when both the indices are subnormal (23%) GHI is so highly likely that the child may undergo only one GH provocative test and brain MRI and, thereafter, may begin GH therapy without any further test. In case of discrepancy, when IGF-I is normal and HV < 25th centile (44% of children), due to the relatively low sensitivity of IGF-I assessment and low specificity of HV, the patient should undergo GH tests and brain MRI. Finally, in the rare case of HV > 25th centile and subnormal IGF-I-values (7%), due to the high specificity of IGF-I measurement, the child should undergo one provocative test and brain MRI for the high suspicion of GHI. Our results suggest that a simple assessment of HV and basal IGF-I may exclude or, in association with only one stimulation test, confirm the diagnosis of GH insufficiency in more than half of patients with short stature.

  15. Investigation of the feasibility of non-invasive optical sensors for the quantitative assessment of dehydration.

    PubMed

    Visser, Cobus; Kieser, Eduard; Dellimore, Kiran; van den Heever, Dawie; Smith, Johan

    2017-10-01

    This study explores the feasibility of prospectively assessing infant dehydration using four non-invasive, optical sensors based on the quantitative and objective measurement of various clinical markers of dehydration. The sensors were investigated to objectively and unobtrusively assess the hydration state of an infant based on the quantification of capillary refill time (CRT), skin recoil time (SRT), skin temperature profile (STP) and skin tissue hydration by means of infrared spectrometry (ISP). To evaluate the performance of the sensors a clinical study was conducted on a cohort of 10 infants (aged 6-36 months) with acute gastroenteritis. High sensitivity and specificity were exhibited by the sensors, in particular the STP and SRT sensors, when combined into a fusion regression model (sensitivity: 0.90, specificity: 0.78). The SRT and STP sensors and the fusion model all outperformed the commonly used "gold standard" clinical dehydration scales including the Gorelick scale (sensitivity: 0.56, specificity: 0.56), CDS scale (sensitivity: 1.0, specificity: 0.2) and WHO scale (sensitivity: 0.13, specificity: 0.79). These results suggest that objective and quantitative assessment of infant dehydration may be possible using the sensors investigated. However, further evaluation of the sensors on a larger sample population is needed before deploying them in a clinical setting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Indication for Computed Tomography Scan in Shoulder Instability: Sensitivity and Specificity of Standard Radiographs to Predict Bone Defects After Traumatic Anterior Glenohumeral Instability.

    PubMed

    Delage Royle, Audrey; Balg, Frédéric; Bouliane, Martin J; Canet-Silvestri, Fanny; Garant-Saine, Laurianne; Sheps, David M; Lapner, Peter; Rouleau, Dominique M

    2017-10-01

    Quantifying glenohumeral bone loss is key in preoperative surgical planning for a successful Bankart repair. Simple radiographs can accurately measure bone defects in cases of recurrent shoulder instability. Cohort study (diagnosis); Level of evidence, 2. A true anteroposterior (AP) view, alone and in combination with an axillary view, was used to evaluate the diagnostic properties of radiographs compared with computed tomography (CT) scan, the current gold standard, to predict significant bone defects in 70 patients. Sensitivity, specificity, and positive and negative predictive values were evaluated and compared. Detection of glenoid bone loss on plain film radiographs, with and without axillary view, had a sensitivity of 86% for both views and a specificity of 73% and 64% with and without the axillary view, respectively. For detection of humeral bone loss, the sensitivity was 8% and 17% and the specificity was 98% and 91% with and without the axillary view, respectively. Regular radiographs would have missed 1 instance of significant bone loss on the glenoid side and 20 on the humeral side. Interobserver reliabilities were moderate for glenoid detection (κ = 0.473-0.503) and poor for the humeral side (κ = 0.278-0.336). Regular radiographs showed suboptimal sensitivity, specificity, and reliability. Therefore, CT scan should be considered in the treatment algorithm for accurate quantification of bone loss to prevent high rates of recurrent instability.

  17. Utility measures of health-related quality of life in patients treated for benign paroxysmal positional vertigo.

    PubMed

    Roberts, Richard A; Abrams, Harvey; Sembach, Melanie K; Lister, Jennifer J; Gans, Richard E; Chisolm, Theresa Hnath

    2009-06-01

    Comparing the effects of different disorders and interventions on health-related quality of life (HRQoL) is important for healthcare policy and accountability. There are two basic approaches to measure HRQoL: questionnaires derived from psychometrics and preference-based measures or utilities derived from econometrics. While disease-specific HRQoL questionnaires, such as the Dizziness Handicap Inventory (DHI), are important because they focus on the impact of a specific problem and its treatments (i.e., vestibular disorders), economic comparisons of the impacts of diseases/disorders and their treatments are typically based on utility assessment. The utility measures for audiology application (UMAA) were developed to measure utilities for various audiologic conditions using a standard computer. The purpose of this study was to determine if the UMAA provides stable, valid, and sensitive utility measures of the effects of benign paroxysmal positional vertigo (BPPV) and its treatment on HRQoL. It was hypothesized that utilities, as measured by the UMAA, would indicate improvement in HRQoL post-treatment for BPPV comparable to a disease-specific health status measure (DHI). The UMAA incorporates three techniques to measure utility: rating scale, standard gamble, and time tradeoff. A utility is a cardinal measure of strength of preference and is measured on a continuum basis from 0.0 (incapacitating dizziness) to 1.0 (no dizziness). Fifty-two adults with BPPV of the posterior semicircular canal completed the UMAA and DHI before treatment and again post-treatment. A subgroup of 15 participants completed the UMAA on two occasions before treatment to assess test-retest stability and to establish critical difference values. Results from this investigation demonstrate that utilities as measured through the UMAA are stable, valid, and comparable to the DHI. Post-treatment utilities were also significantly higher than pretreatment utilities, indicating that the utilities, as measured through the UMAA, are sensitive to improvement in HRQoL after BPPV treatment. Utilities as measured through the UMAA seem sensitive to changes in HRQoL after treatment of BPPV. Since the UMAA can be used to measure patient preference (i.e., utility), it may be useful for comparison of specific audiologic conditions, such as BPPV, to nonaudiologic conditions, such as cardiovascular disease and kidney disease.

  18. Towards Measuring Brain Function on Groups of People in the Real World

    PubMed Central

    Gevins, Alan; Chan, Cynthia S.; Sam-Vargas, Lita

    2012-01-01

    In three studies, EEGs from three groups of participants were recorded during progressively more real world situations after drinking alcoholic beverages that brought breath alcohol contents near the limit for driving in California 30 minutes after drinking. A simple equation that measured neurophysiological effects of alcohol in the first group of 15 participants performing repetitive cognitive tasks was applied to a second group of 15 operating an automobile driving simulator, and to a third group of 10 ambulatory people recorded simultaneously during a cocktail party. The equation derived from the first group quantified alcohol’s effect by combining measures of higher frequency (beta) and lower frequency (theta) power into a single score. It produced an Area Under the Receiver Operator Characteristic Curve of .73 (p<.05; 67% sensitivity in recognizing alcohol and 87% specificity in recognizing placebo). Applying the same equation to the second group operating the driving simulator, AUC was .95, (p<.0001; 93% sensitivity and 73% specificity), while for the cocktail party group AUC was .87 (p<.01; 80% sensitivity and 80% specificity). EEG scores were significantly related to breath alcohol content in all studies. Some individuals differed markedly from the overall response evident in their respective groups. The feasibility of measuring the neurophysiological effect of a psychoactive substance from an entire group of ambulatory people at a cocktail party suggests that future studies may be able to fruitfully apply brain function measures derived under rigorously controlled laboratory conditions to assess drug effects on groups of people interacting in real world situations. PMID:22957099

  19. Predicting HIV RNA virologic outcome at 52-weeks follow-up in antiretroviral clinical trials. The INCAS and AVANTI Study Groups.

    PubMed

    Raboud, J M; Rae, S; Montaner, J S

    2000-08-15

    To determine the ability of intermediate plasma viral load (pVL) measurements to predict virologic outcome at 52 weeks of follow-up in clinical trials of antiretroviral therapy. Individual patient data from three clinical trials (INCAS, AVANTI-2 and AVANTI-3) were combined into a single database. Virologic success was defined to be plasma viral load (pVL) <500 copies/ml at week 52. The sensitivity and specificity of intermediate pVL measurements below the limit of detection, 100, 500, 1000, and 5000 copies/ml to predict virologic success were calculated. The sensitivity, specificity, and positive and negative predictive values of a pVL measurement <1000 copies/ml at week 16 to predict virologic outcome at week 52 were 74%, 74%, 48%, and 90%, respectively, for patients on double therapy. For patients on triple therapy, the sensitivity, specificity, and positive and negative predictive values of a pVL measurement <50 copies/ml at week 16 to predict virologic outcome were 68%, 68%, 80%, and 47%, respectively. For patients receiving double therapy, a poor virologic result at an intermediate week of follow-up is a strong indicator of virologic failure at 52 weeks whereas intermediate virologic success is no guarantee of success at 1 year. For patients on triple therapy, disappointing intermediate results do not preclude virologic success at 1 year and intermediate successes are more likely to be sustained.

  20. Comparison of non-invasive methods for the assessment of haemodynamic drug effects in healthy male and female volunteers: sex differences in cardiovascular responsiveness.

    PubMed Central

    Wolzt, M; Schmetterer, L; Rheinberger, A; Salomon, A; Unfried, C; Breiteneder, H; Ehringer, H; Eichler, H G; Fercher, A F

    1995-01-01

    1. The study was performed to determine the sensitivity and short-term and day-to-day variability of a novel technique based on laser interferometry of ocular fundus pulsations and of non-invasive methods for the quantification of haemodynamic drug effects. An additional aim was to assess sex differences in haemodynamic responsiveness to cardiovascular drugs in male and female healthy volunteers. 2. Ten males and nine females (age range 20-33 years) were studied in a double-blind, randomized, cross-over trial. Simultaneous measurements from systemic haemodynamics, laser interferometry of ocular fundus pulsations, systolic time intervals from mechanocardiography, a/b ratio from oxymetric fingerplethysmography and Doppler sonography of the radial artery were used to describe the haemodynamic effects of cumulative, stepwise increasing intravenous doses of phenylephrine, isoprenaline, sodium nitroprusside and of placebo. 3. Laser interferometry detected the isoprenaline-effects at the lowest dose level of 0.1 micrograms min-1 with a high signal-to-noise ratio. The reproducibility of measurements under baseline was high, no changes were observed after systemically effective doses of phenylephrine or sodium nitroprusside. Systolic time intervals were sensitive and specific for isoprenaline-induced effects, PEP and QS2c-measurements had high reproducibility. Fingerplethysmography proved a sensitive measurement for the detection of the vasodilating effects of sodium nitroprusside, but was not specific, and showed low reproducibility. Measurements from Doppler sonography had lower reproducibility and sensitivity compared with the other applied methods. 4. There was a significant sex difference for several of the haemodynamic parameters under baseline conditions; however, the responsiveness to the drugs under study was not different, when drug effects were expressed as %-change from the baseline. 5. Laser interferometry is a valuable non-invasive, highly sensitive and specific approach for the detection of pulse pressure changes. A battery of non-invasive tests appears useful for the characterization of cardiovascular drugs. Gender differences may not pose a relevant problem for the study of acute haemodynamic effects of cardiovascular drugs. Images Figure 1 PMID:7640140

  1. Evaluation of NOx Emissions and Modeling

    NASA Astrophysics Data System (ADS)

    Henderson, B. H.; Simon, H. A.; Timin, B.; Dolwick, P. D.; Owen, R. C.; Eyth, A.; Foley, K.; Toro, C.; Baker, K. R.

    2017-12-01

    Studies focusing on ambient measurements of NOy have concluded that NOx emissions are overestimated and some have attributed the error to the onroad mobile sector. We investigate this conclusion to identify the cause of observed bias. First, we compare DISCOVER-AQ Baltimore ambient measurements to fine-scale modeling with NOy tagged by sector. Sector-based relationships with bias are present, but these are sensitive to simulated vertical mixing. This is evident both in sensitivity to mixing parameterization and the seasonal patterns of bias. We also evaluate observation-based indicators, like CO:NOy ratios, that are commonly used to diagnose emissions inventories. Second, we examine the sensitivity of predicted NOx and NOy to temporal allocation of emissions. We investigate alternative temporal allocations for EGUs without CEMS, on-road mobile, and several non-road categories. These results show some location-specific sensitivity and will lead to some improved temporal allocations. Third, near-road studies have inherently fewer confounding variables, and have been examined for more direct evaluation of emissions and dispersion models. From 2008-2011, the EPA and FHWA conducted near-road studies in Las Vegas and Detroit. These measurements are used to more directly evaluate the emissions and dispersion using site-specific traffic data. In addition, the site-specific emissions are being compared to the emissions used in larger-scale photochemical modeling to identify key discrepancies. These efforts are part of a larger coordinated effort by EPA scientist to ensure the highest quality in emissions and model processes. We look forward to sharing the state of these analyses and expected updates.

  2. Rejection sensitivity prospectively predicts increased rumination.

    PubMed

    Pearson, Katherine A; Watkins, Edward R; Mullan, Eugene G

    2011-10-01

    Converging research findings indicate that rumination is correlated with a specific maladaptive interpersonal style encapsulating submissive (overly-accommodating, non-assertive and self-sacrificing) behaviours, and an attachment orientation characterised by rejection sensitivity. This study examined the prospective longitudinal relationship between rumination, the submissive interpersonal style, and rejection sensitivity by comparing two alternative hypotheses: (a) the submissive interpersonal style and rejection sensitivity prospectively predict increased rumination; (b) rumination prospectively predicts the submissive interpersonal style and rejection sensitivity. Currently depressed (n = 22), previously depressed (n = 42) and never depressed (n = 28) individuals completed self-report measures assessing depressive rumination and key psychosocial measures of interpersonal style and behaviours, at baseline and again six months later. Baseline rejection sensitivity prospectively predicted increased rumination six months later, after statistically controlling for baseline rumination, gender and depression. Baseline rumination did not predict the submissive interpersonal style or rejection sensitivity. The results provide a first step towards delineating a potential casual relationship between rejection sensitivity and rumination, and suggest the potential value of clinical assessment and intervention for both rejection sensitivity and rumination in individuals who present with either difficulty. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Influence of personal characteristics of individual women on sensitivity and specificity of mammography in the Million Women Study: cohort study

    PubMed Central

    Banks, Emily; Reeves, Gillian; Beral, Valerie; Bull, Diana; Crossley, Barbara; Simmonds, Moya; Hilton, Elizabeth; Bailey, Stephen; Barrett, Nigel; Briers, Peter; English, Ruth; Jackson, Alan; Kutt, Elizabeth; Lavelle, Janet; Rockall, Linda; Wallis, Matthew G; Wilson, Mary; Patnick, Julietta

    2004-01-01

    Objectives To examine how lifestyle, hormonal, and other factors influence the sensitivity and specificity of mammography. Methods Women recruited into the Million Women Study completed a questionnaire about various personal factors before routine mammographic screening. A sample of 122 355 women aged 50-64 years were followed for outcome of screening and incident breast cancer in the next 12 months. Sensitivity and specificity were calculated by using standard definitions, with adjustment for potential confounding factors. Results Breast cancer was diagnosed in 726 (0.6%) women, 629 in screen positive and 97 in screen negative women; 3885 (3.2%) were screen positive but had no subsequent diagnosis of breast cancer. Overall sensitivity was 86.6% and specificity was 96.8%. Three factors had an adverse effect on both measures: use of hormone replacement therapy (sensitivity: 83.0% (95% confidence interval 77.4% to 87.6%), 84.7% (73.9% to 91.6%), and 92.1% (87.6% to 95.0%); specificity: 96.8% (96.6% to 97.0%), 97.8% (97.5% to 98.0%), and 98.1% (98.0% to 98.2%), respectively, for current, past, and never use); previous breast surgery v no previous breast surgery (sensitivity: 83.5% (75.7% to 89.1%) v 89.4% (86.5% to 91.8%); specificity: 96.2% (95.8% to 96.5%) v 97.4% (97.3% to 97.5%), respectively); and body mass index < 25 v ≥ 25 (sensitivity: 85.7% (81.2% to 89.3%) v 91.0% (87.5% to 93.6%); specificity: 97.2% (97.0% to 97.3%) v 97.4% (97.3% to 97.6%), respectively). Neither sensitivity nor specificity varied significantly according to age, family history of breast cancer, parity, past oral contraceptive use, tubal ligation, physical activity, smoking, or alcohol consumption. Conclusions The efficiency, and possibly the effectiveness, of mammographic screening is lower in users of hormone replacement therapy, in women with previous breast surgery, and in thin women compared with other women. PMID:15331472

  4. [Clinical auxiliary diagnosis value of high frequency ultrasonographic measurements of the thickness of transverse carpal ligaments in carpal tunnel syndrome patients].

    PubMed

    Xu, L; Chen, F M; Wang, L; Zhang, P X; Jiang, X R

    2016-04-18

    To evaluate the meaning and value of high-frequency ultrasound in the diagnosis of carpal tunnel syndrome (CTS). In this study, 48 patients (unilateral hand) with CTS were analyzed. The thickness of transverse carpal ligaments at the pisiform bone was measured using high-frequency ultrasound. Open carpal tunnel release procedure was performed in the 48 CTS patients, and the thickness of transverse carpal ligaments at the hamate hook bone measured using vernier caliper under direct vision. The accuracy of thickness of transverse carpal ligaments was evaluated using high-frequency ultrasound. high-frequency ultrasound measurement of thickness of transverse carpal ligaments at the hamate hook bone and pisiform bone, and determination of the diagnostic threshold measurement index using receiver operating characteristic (ROC) curve, sensitivity and specificity were performed and the correlation between the thickness of transverse carpal ligaments and nerve conduction study (NCS) analyzed. The thickness of transverse carpal ligaments in the CTS patients were (0.42±0.08) cm (high-frequency ultrasound) and (0.41±0.06) cm (operation) at hamate hook bone, and there was no significant difference between the two ways (t=0.672, P>0.05). The optimal cut-off value of the transverse carpal ligaments at hamate hook bone was 0.385 cm, the sensitivity 0.775, and the specificity 0.788. The optimal cut-off value of the transverse carpal ligaments at the pisiform bone was 0.315 cm, the sensitivity 0.950, and the specificity 1.000. The transverse carpal ligaments thickness and wrist-index finger sensory nerve conduction velocity (SCV), wrist-middle finger SCV showed a negative correlation. High frequency ultrasound measurements of thickness of transverse carpal ligaments is a valuable method for the diagnosis of CTS.

  5. Is Grey Level a Suitable Alternative to Low-Contrast Penetration as a Serial Measure of Sensitivity in Computerised Ultrasound Quality Assurance?

    PubMed

    Dudley, Nicholas J; Gibson, Nicholas M

    2017-02-01

    The aim of this study was to test the hypothesis that grey levels are a suitable alternative measure of sensitivity in ultrasound imaging quality assurance, as there are several caveats in the use of penetration depth. In a primary cohort of nine probes, where measurements had been made for 6 to 34 mo, both penetration depth and mean grey level fell below tolerance for six probes; both penetration depth and mean grey level remained within tolerance for three probes. In a secondary cohort where a measurement programme had been in place for a shorter period, grey level and/or penetration depth fell below tolerance in 15 of 66 probes; the sensitivity and specificity of at least 10% loss of grey level in predicting >5% loss in penetration depth were 91% and 93%, respectively. A loss of grey level accompanies a loss of penetration and provides a suitable alternative measure of sensitivity. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  6. Allergy and parasites reevaluated: wide-scale induction of chronic urticaria by the ubiquitous fish-nematode Anisakis simplex in an endemic region.

    PubMed

    Daschner, A; Vega de la Osada, F; Pascual, C Y

    2005-01-01

    The ubiquitous fish-nematode Anisakis simplex produces acute urticaria or angioedema in the course of gastro-allergic anisakiasis. We studied the relationship between this nematode and chronic urticaria (CU), as well as the clinical usefulness of measuring specific IgG4 in A. simplex-sensitized patients with CU. First, the prevalence of sensitization to A. simplex was estimated in 135 consecutive CU patients and the result was compared with known data about sensitization in a healthy population. Then, clinical response to a 2-month diet without fish was analyzed in 76 CU patients. The improvement rate in patients with and without sensitization to A. simplex was compared. Finally, the improvement rate, other clinical data and specific immunoglobulins in sensitized patients with and without detectable specific IgG4 were compared. a) The A. simplex sensitization rate in CU patients was 52.6 % compared with a known prevalence of between 16 and 20 % in our region. b) Of 65 sensitized patients, 52 experienced clinical improvement after the diet compared with only three of 11 patients without sensitization to A. simplex (p = 0.001). c) Of 43 patients with detectable specific IgG4, 38 showed clinical improvement compared with only 14 of 22 patients without detectable IgG4 (p = 0.02). Eight of nine patients with previous fish-associated cutaneous symptoms had detectable specific IgG4 compared with 15 of 32 patients who reported no previous fish-associated symptoms or acute urticaria (p = 0.03). Our results indicate that A. simplex is a possibly widespread etiologic agent able to induce CU. This parasite model constitutes the first report that associates an infectious agent with CU on a large scale. The detection of IgG4 antibodies reflects a previous acute parasitic infection and a temporary diet without fish improves symptoms in most patients with detectable specific IgG4.

  7. Validity and Reliability of Tympanometric Measures for Pediatric Patients.

    ERIC Educational Resources Information Center

    Karzon, Roanne G.

    1991-01-01

    Sensitivity and specificity of static acoustic admittance (SAA) and tympanometric width (TW) were assessed for 116 pediatric patients. A statistically significant change in SAA was observed in immediate repeat measures. No significant change across the two sequential measures was observed for TW, peak pressure, or the estimate of ear canal volume.…

  8. Targeted Quantitation of Proteins by Mass Spectrometry

    PubMed Central

    2013-01-01

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement. PMID:23517332

  9. Targeted quantitation of proteins by mass spectrometry.

    PubMed

    Liebler, Daniel C; Zimmerman, Lisa J

    2013-06-04

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement.

  10. Specificity of disgust sensitivity in the prediction of fear and disgust responding to a brief spider exposure.

    PubMed

    Olatunji, Bunmi O; Deacon, Brett

    2008-01-01

    This study examined the specificity of disgust sensitivity in predicting fear and disgust responses to exposure to a spider. Participants high (n=22) and low (n=28) in spider fear completed self-report measures of disgust sensitivity, contamination fear, anxiety, and negative affect. They then participated in a behavioral avoidance task (BAT) in which they were briefly exposed to a realistic-looking, but fake, tarantula. Results revealed that disgust sensitivity was associated with fear and disgust responding to the BAT. The association between disgust sensitivity and disgust responding to the BAT remained significant after controlling for gender, spider fear group membership, contamination fear, anxiety, and negative affect. However, the association between disgust sensitivity and fear responding to the BAT was only marginally significant after controlling for the same variables. Contamination fear was also strongly related to fear and disgust responding to the BAT. However, this relationship was fully mediated by disgust sensitivity. These findings indicate that disgust sensitivity has a unique association with aversive responding to spiders. The implications of these findings for better understanding the complex role of fear and disgust as they related to disgust sensitivity in spider phobia are discussed.

  11. Measuring New Born Foot Length to Identify Small Babies in Need of Extra Care: a Cross-Sectional Hospital Based Study

    PubMed Central

    Mukherjee, Satarupa; Roy, Prithwish; Mitra, Souvik; Samanta, Moumita; Chatterjee, Sukanta

    2013-01-01

    Objective The neonatal mortality rate (NMR) continues to remain quite high, one important cause being preterm deliveries. The main obstacle in the pathway towards decreasing NMR is identification of babies in need of extra care. To analyze the utility of newborn foot length as a proxy measure for birth weight and gestational age. Methods A cross-sectional study done in a hospital of eastern India with 351 babies during 4 months. Right foot length of each recorded using a plastic, stiff ruler. Findings 48.1% babies were preterm, 51.8% low birth weight (LBW) and 33.3% very low birth weight (VLBW). Foot length less than 7.75 cm has 92.3% sensitivity and 86.3% specificity for identification of preterm neonates. For identification of LBW babies (<2500 gm) a foot length less than 7.85cm has 100% sensitivity and 95.3% specificity. Foot length less than 6.85 cm has 100% sensitivity and 94.9% specifity for identification of VLBW babies (<1500 gm). Conclusion Foot length may be used in the identification of LBW and preterm babies who are in need of extra care. PMID:24800008

  12. EXHALED CARBON MONOXIDE LEVELS AMONG TOBACCO SMOKERS BY AGE.

    PubMed

    Chatrchaiwiwatana, Supaporn; Ratanasiri, Amornrat

    2017-03-01

    Measurement of exhaled carbon monoxide (ECO) has been used to confirm self-reported tobacco smoking. There is little data regarding ECO levels among Thai tobacco smokers by age. The objectives of this study were to determine ECO cutoff level to confirm tobacco smoking and to assess whether the cutoff level varies by age. During 2009 we evaluated 875 Thai volunteers aged 16-70 years, residing in Pathum Thani (central Thailand) and Khon Kaen (northeastern Thailand). Among the 875 volunteers, there were 584 non-smokers and 291 smokers. Each subject was interviewed and had their ECO level measured. The mean ECO level was 11.24 ppm among smokers and 2.25 ppm among non-smokers. The best ECO cutoff level to distinguish 291smokers from 584 non-smokers was 5 ppm (sensitivity 79.0%, specificity 89.9%).The optimal ECO cutoff level varied by age-group. For subjects aged 16-25 years, the best ECO cutoff level was 4 ppm (sensitivity 85.2%, specificity 77.5%) and for subject aged 26-70 years, the best ECO cutoff level was 5 ppm (sensitivity 79.4%, specificity 91.2%).These levels by age should be used among Thai subjects to determine smoking.

  13. Late-night salivary cortisol for diagnosis of Cushing's syndrome by liquid chromatography/tandem mass spectrometry assay.

    PubMed

    Erickson, Dana; Singh, Ravinder J; Sathananthan, Airani; Vella, Adrian; Bryant, Sandra C

    2012-04-01

    Late-night salivary cortisol (LNSC) measurements have been increasingly used by physicians as an initial diagnostic test for evaluation of patients with clinical suspicion of Cushing's syndrome (CS). Published studies include various numbers of cases, controls and importantly, various assay methods (vast majority various immunoassays), as well as various methods to generate cut-points. The retrospective study evaluated the diagnostic utility of LNSC measurements in 249 patients evaluated for possibility of CS because of various clinical conditions using liquid chromatography/tandem mass spectrometry method (LC-MS/MS). CS was confirmed in 47 patients (18·9%) and excluded in 202 (81·1%) patients at the time of analysis. Late-night salivary cortisol was abnormal or >2·8 nmol/l in 35 of 47 patients with CS; sensitivity of 74·5% and elevated in 20 of 202 patients who were found not to have CS; specificity 90·1%. Using receiver-operator characteristic statistics for calculation of the most optimal sensitivity and specificity, the cut-off based on this data was LNSC > 2·1 nmol/l with sensitivity of 83·0% and specificity of 84·2%. Analysis of data at one referral institution showed somewhat limited sensitivity of LNSC for diagnosis of CS using current reference ranges. © 2012 Blackwell Publishing Ltd.

  14. Vibration Sensitivity of a Wide-Temperature Electronically Scanned Pressure Measurement (ESP) Module

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J.; Garza, Frederico R.

    2001-01-01

    A vibration sensitivity test was conducted on a Wide-Temperature ESP module. The test object was Module "M4," a 16-channel, 4 psi unit scheduled for installation in the Arc Sector of NTF. The module was installed on a vibration exciter and loaded to positive then negative full-scale pressures (+/-2.5 psid). Test variables were the following: Vibration frequencies: 20, 55, 75 Hz. Vibration level: 1 g. Vibration axes: X, Y, Z. The pressure response was measured on each channel, first without and then with the vibration turned on, and the difference analyzed by means of the statistical t-test. The results show that the vibration sensitivity does not exceed 0.01% Full Scale Output per g (with the exception of one channel on one axis) to a 95 percent confidence level. This specification, limited by the resolution of the pressure source, lies well below the total uncertainty specification of 0.1 percent Full Scale Output.

  15. Photoacoustic and ultrasound characterization of bone composition

    NASA Astrophysics Data System (ADS)

    Lashkari, Bahman; Yang, Lifeng; Liu, Lixian; Tan, Joel W. Y.; Mandelis, Andreas

    2015-02-01

    This study examines the sensitivity and specificity of backscattered ultrasound (US) and backscattering photoacoustic (PA) signals for bone composition variation assessment. The conventional approach in the evaluation of bone health relies on measurement of bone mineral density (BMD). Although, a crucial and probably the most important parameter, BMD is not the only factor defining the bone health. New trends in osteoporosis research, also pursue the changes in collagen content and cross-links with bone diseases and aging. Therefore, any non-invasive method that can assess any of these parameters can improve the diagnostic tools and also can help with the biomedical studies on the diseases themselves. Our previous studies show that both US and PA are responsive to changes in the BMD, PA is, in addition, sensitive to changes in the collagen content of the bone. Measurements were performed on bone samples before and after mild demineralization and decollagenization at the exact same points. Results show that combining both modalities can enhance the sensitivity and specificity of diagnostic tool.

  16. Diagnosing synaesthesia with online colour pickers: maximising sensitivity and specificity.

    PubMed

    Rothen, Nicolas; Seth, Anil K; Witzel, Christoph; Ward, Jamie

    2013-04-30

    The most commonly used method for formally assessing grapheme-colour synaesthesia (i.e., experiencing colours in response to letter and/or number stimuli) involves selecting colours from a large colour palette on several occasions and measuring consistency of the colours selected. However, the ability to diagnose synaesthesia using this method depends on several factors that have not been directly contrasted. These include the type of colour space used (e.g., RGB, HSV, CIELUV, CIELAB) and different measures of consistency (e.g., city block and Euclidean distance in colour space). This study aims to find the most reliable way of diagnosing grapheme-colour synaesthesia based on maximising sensitivity (i.e., ability of a test to identify true synaesthetes) and specificity (i.e., ability of a test to identify true non-synaesthetes). We show, applying ROC (receiver operating characteristics) to binary classification of a large sample of self-declared synaesthetes and non-synaesthetes, that the consistency criterion (i.e., cut-off value) for diagnosing synaesthesia is considerably higher than the current standard in the field. We also show that methods based on perceptual CIELUV and CIELAB colour models (rather than RGB and HSV colour representations) and Euclidean distances offer an even greater sensitivity and specificity than most currently used measures. Together, these findings offer improved heuristics for the behavioural assessment of grapheme-colour synaesthesia. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Fixation Preference and Visual Acuity Testing in a Population-based Cohort of Preschool Children with Amblyopia Risk Factors

    PubMed Central

    Cotter, Susan A.; Tarczy-Hornoch, Kristina; Song, Erin; Lin, Jesse; Borchert, Mark; Azen, Stanley P.; Varma, Rohit

    2009-01-01

    Purpose To compare the clinical assessment of fixation preference (FP) to visual acuity (VA) in a population-based sample of preschool children with amblyopia risk factors. Design Evaluation of diagnostic test in a population-based study. Participants Two hundred forty-three children with amblyopia and/or strabismus, aged 30–72 months, living in Los Angeles County, California. Methods Before measuring VA, FP testing was performed at near and usually without correction, using the binocular fixation pattern in children with strabismus >10 diopters (D), or the induced tropia test for children with strabismus ≤10D, or without strabismus. We determined the sensitivity and specificity of FP testing for predicting unilateral amblyopia, defined by optotype VA, among children with amblyopia risk factors. Main Outcome Measure Grade of FP. Results Sensitivity of FP testing for amblyopia among children with anisometropia was 20% (9/44) and specificity was 94% (102/109). Among strabismic children, sensitivity was 69% (9/13; worse in children 30–47 than 48–72 months old) and specificity was 79% (70/89), with similar findings for esotropia and exotropia. Conclusion The ability of FP testing to correctly identify amblyopia in preschool children with amblyopia risk factors is poor. Clinicians should be wary of using FP as a surrogate measure of intraocular difference in VA in young children. PMID:18962921

  18. A receiver operated curve-based evaluation of change in sensitivity and specificity of cotinine urinalysis for detecting active tobacco use.

    PubMed

    Balhara, Yatan Pal Singh; Jain, Raka

    2013-01-01

    Tobacco use has been associated with various carcinomas including lung, esophagus, larynx, mouth, throat, kidney, bladder, pancreas, stomach, and cervix. Biomarkers such as concentration of cotinine in the blood, urine, or saliva have been used as objective measures to distinguish nonusers and users of tobacco products. A change in the cut-off value of urinary cotinine to detect active tobacco use is associated with a change in sensitivity and sensitivity of detection. The current study aimed at assessing the impact of using different cut-off thresholds of urinary cotinine on sensitivity and specificity of detection of smoking and smokeless tobacco product use among psychiatric patients. All the male subjects attending the psychiatry out-patient department of the tertiary care multispecialty teaching hospital constituted the sample frame for the current study in a cross-sectionally. Quantitative urinary cotinine assay was done by using ELISA kits of Calbiotech. Inc., USA. We used the receiver operating characteristic (ROC) curve to assess the sensitivity and specificity of various cut-off values of urinary cotinine to identify active smokers and users of smokeless tobacco products. ROC analysis of urinary cotinine levels in detection of self-reported smoking provided the area under curve (AUC) of 0.434. Similarly, the ROC analysis of urinary cotinine levels in detection of self-reported smoking revealed AUC of 0.44. The highest sensitivity and specificity of 100% for smoking were detected at the urinary cut-off value greater than or equal to 2.47 ng/ml. The choice of cut-off value of urinary cotinine used to distinguish nonusers form active users of tobacco products impacts the sensitivity as well as specificity of detection.

  19. Circulating immune complexes as markers of response to chemotherapy in malignant teratomas and gestational trophoblastic tumours.

    PubMed Central

    Begent, R. H.; Chester, K. A.; Walker, L. C.; Tucker, D. F.

    1982-01-01

    Concentrations of circulating immune complexes (CIC) were measured serially during chemotherapy of 22 patients with gestational trophoblastic tumours (GTT) and 11 patients with malignant teratoma (MT) by the polyethylene glycol precipitation and CIq solid-phase assays. Results were correlated with tumour response as measured by serum concentrations of human chorionic gonadotrophin (hCG) and alpha-foetoprotein (AFP). CIC concentrations correlated with disease status in the early stages of treatment in 4/22 patients with GTT and 5/11 with MT. CIC assays were less sensitive than hCG and AFP as a monitor of disease, and also less specific, in that 8 patients with GTT and 5 with MT developed raised CIC concentrations during chemotherapy in spite of sustained complete remission. Measurements of CIC concentrations by present methods are neither sufficiently sensitive nor specific to be of clinical value as a tumour marker in GTT and MT, and this casts doubt on their potential value in other malignancies. Attention should be directed to identification of the components of CIC, some of which may be more cancer-specific. PMID:6174138

  20. Accurate antemortem diagnosis of equine protozoal myeloencephalitis (EPM) based on detecting intrathecal antibodies against Sarcocystis neurona using the SnSAG2 and SnSAG4/3 ELISAs.

    PubMed

    Reed, S M; Howe, D K; Morrow, J K; Graves, A; Yeargan, M R; Johnson, A L; MacKay, R J; Furr, M; Saville, W J A; Williams, N M

    2013-01-01

    Recent work demonstrated the value of antigen-specific antibody indices (AI and C-value) to detect intrathecal antibody production against Sarcocystis neurona for antemortem diagnosis of equine protozoal myeloencephalitis (EPM). The study was conducted to assess whether the antigen-specific antibody indices can be reduced to a simple serum : cerebrospinal fluid (CSF) titer ratio to achieve accurate EPM diagnosis. Paired serum and CSF samples from 128 horses diagnosed by postmortem examination. The sample set included 44 EPM cases, 35 cervical-vertebral malformation (CVM) cases, 39 neurologic cases other than EPM or CVM, and 10 non-neurologic cases. Antibodies against S. neurona were measured in serum and CSF pairs using the SnSAG2 and SnSAG4/3 (SnSAG2, 4/3) ELISAs, and the ratio of each respective serum titer to CSF titer was determined. Likelihood ratios and diagnostic sensitivity and specificity were calculated based on serum titers, CSF titers, and serum : CSF titer ratios. Excellent diagnostic sensitivity and specificity was obtained from the SnSAG2, 4/3 serum : CSF titer ratio. Sensitivity and specificity of 93.2 and 81.1%, respectively, were achieved using a ratio cutoff of ≤100, whereas sensitivity and specificity were 86.4 and 95.9%, respectively, if a more rigorous cutoff of ≤50 was used. Antibody titers in CSF also provided good diagnostic accuracy. Serum antibody titers alone yielded much lower sensitivity and specificity. The study confirms the value of detecting intrathecal antibody production for antemortem diagnosis of EPM, and they further show that the antigen-specific antibody indices can be reduced in practice to a simple serum : CSF titer ratio. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  1. The cut-off values of anthropometric variables for predicting mild cognitive impairment in Malaysian older adults: a large population based cross-sectional study.

    PubMed

    Won, Huiloo; Abdul, Manaf Zahara; Mat Ludin, Arimi Fitri; Omar, Mohd Azahadi; Razali, Rosdinom; Shahar, Suzana

    2017-01-01

    Older adults are at risk of mild cognitive impairment (MCI), and simple anthropometric measurements can be used to screen for this condition. Thus, the aim of this study was to explore the cut-off values of body mass index (BMI) and waist circumference (WC) for predicting the risk of MCI in older Malaysian adults. A total of 2,240 Malaysian older adults aged ≥60 years were recruited using multistage random sampling in a population based cross-sectional study. Receiver operating characteristic (ROC) curve was used to determine the cut-off values of BMI and WC with optimum sensitivity and specificity for the detection of MCI. Age, gender, years of education, smoking habit, alcohol consumption, depression, and medical conditions were used as confounding factors in this analysis. A BMI cut-off value of 26 kg/m 2 (area under the receiver operating characteristic curve [AUC] 0.725; sensitivity 90.5%; specificity 38.8%) was appropriate in identifying the risk of getting MCI in both men and women. The optimum WC cut-offs for likelihood of MCI were 90 cm (AUC 0.745; sensitivity 78.0%; specificity 59.8%) for men and 82 cm (AUC 0.714; sensitivity 84.3%; specificity 49.7%) for women. The optimum calf circumference (CC) cut-off values for identifying MCI were 29 cm (AUC 0.731; sensitivity 72.6%; specificity 61.1%) for men and 26 cm (AUC 0.598; sensitivity 79.1%; specificity 45.3%) for women. The cut-off values could be advocated and used as part of the screening of MCI among older Malaysian adults. There is a need to further determine the predictive values of these cut-off points on outcomes through longitudinal study design.

  2. Acute Brain Imaging in Children: Can MRI Replace CT as a Screening Tool?

    PubMed

    Wagner, Matthias W; Kontzialis, Marinos; Seeburg, Daniel; Stern, Steven E; Oshmyansky, Alexander; Poretti, Andrea; Huisman, Thierry A G M

    2016-01-01

    To determine if axial T2-weighted imaging can serve as screening tool for pediatric brain imaging. We retrospectively evaluated consecutive brain magnetic resonance imaging (MRI) data of 161 children (74 girls) with a mean age of 7.44 ± 5.71 years. Standard of reference was the final report of neuroradiology attendings. Three readers with different levels of experience were blinded for clinical diagnoses and study indications. First, readers studied only the axial T2-weighted screening sequence. Second, they studied all available anatomical and functional MRI sequences as performed per standard protocol for each clinical indication. The readings were classified as normal or abnormal. Sensitivity and specificity were measured. Axial T2 screening yielded a sensitivity of 77-88% and a specificity of 92%. The full studies/data sets had a sensitivity of 89-95% and a specificity of 86-93%. Nineteen of 167 studies were acquired for acute and 148 of 167 studies for nonacute clinical indication. Twenty-five false-negative diagnoses paneled in three groups were made by all readers together. Readers misread four of 19 studies with acute and 21 of 148 studies with nonacute clinical indication. Four of 21 misread studies with nonacute indications harbored unexpected findings needing management. Axial T2 screening can detect pediatric brain abnormalities with high sensitivity and specificity and can possibly replace CT as screening tool if the reading physician is aware of possible limitations/pitfalls. The level of experience influences sensitivity and specificity. Adding diffusion-weighted imaging and susceptibility-weighted imaging to a 3-dimensional T2-weighted sequence would most likely further increase sensitivity and specificity. Copyright © 2015 by the American Society of Neuroimaging.

  3. Home oximetry to screen for obstructive sleep apnoea in Down syndrome.

    PubMed

    Hill, Catherine M; Elphick, Heather E; Farquhar, Michael; Gringras, Paul; Pickering, Ruth M; Kingshott, Ruth N; Martin, Jane; Reynolds, Janine; Joyce, Anna; Gavlak, Johanna C; Evans, Hazel J

    2018-05-14

    Children with Down syndrome are at high risk of obstructive sleep apnoea (OSA) and screening is recommended. Diagnosis of OSA should be confirmed with multichannel sleep studies. We aimed to determine whether home pulse oximetry (HPO) discriminates children at high risk of OSA, who need further diagnostic multichannel sleep studies. Cross-sectional prospective study in a training sample recruited through three UK centres. Validation sample used single-centre retrospective analysis of clinical data. Children with Down syndrome aged 0.5-6 years. Diagnostic multichannel sleep study and HPO. Sensitivity and specificity of HPO to predict moderate-to-severe OSA. 161/202 children with Down syndrome met quality criteria for inclusion and 25 had OSA. In this training sample, the best HPO parameter predictors of OSA were the delta 12 s index >0.555 (sensitivity 92%, specificity 65%) and 3% oxyhaemoglobin (SpO 2 ) desaturation index (3% ODI)>6.15 dips/hour (sensitivity 92%, specificity 63%). Combining variables (delta 12 s index, 3% ODI, mean and minimum SpO 2 ) achieved sensitivity of 96% but reduced specificity to 52%. All predictors retained or improved sensitivity in a clinical validation sample of 50 children with variable loss of specificity, best overall was the delta 12 s index, a measure of baseline SpO 2 variability (sensitivity 92%; specificity 63%). HPO screening could halve the number of children with Down syndrome needing multichannel sleep studies and reduce the burden on children, families and health services alike. This approach offers a practical universal screening approach for OSA in Down syndrome that is accessible to the non-specialist paediatrician. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Prediction of venous wound healing with laser speckle imaging.

    PubMed

    van Vuuren, Timme Maj; Van Zandvoort, Carina; Doganci, Suat; Zwiers, Ineke; tenCate-Hoek, Arina J; Kurstjens, Ralph Lm; Wittens, Cees Ha

    2017-12-01

    Introduction Laser speckle imaging is used for noninvasive assessment of blood flow of cutaneous wounds. The aim of this study was to assess if laser speckle imaging can be used as a predictor of venous ulcer healing. Methods After generating the flux speckle images, three regions of interest (ROI) were identified to measure the flow. Sensitivity, specificity, negative predictive value, and positive predictive value for ulcer healing were calculated. Results In total, 17 limbs were included. A sensitivity of 92.3%, specificity of 75.0%, PPV of 80.0%, and NPV 75.0% were found in predicting wound healing based on laser speckle images. Mean flux values were lowest in the center (ROI I) and showed an increase at the wound edge (ROI II, p = 0.03). Conclusion Laser speckle imaging shows acceptable sensitivity and specificity rates in predicting venous ulcer healing. The wound edge proved to be the best probability for the prediction of wound healing.

  5. Validity of Teacher-Based Vision Screening and Factors Associated with the Accuracy of Vision Screening in Vietnamese Children.

    PubMed

    Paudel, Prakash; Kovai, Vilas; Naduvilath, Thomas; Phuong, Ha Thanh; Ho, Suit May; Giap, Nguyen Viet

    2016-01-01

    To assess validity of teacher-based vision screening and elicit factors associated with accuracy of vision screening in Vietnam. After brief training, teachers independently measured visual acuity (VA) in 555 children aged 12-15 years in Ba Ria - Vung Tau Province. Teacher VA measurements were compared to those of refractionists. Sensitivity, specificity, positive predictive value and negative predictive value were calculated for uncorrected VA (UVA) and presenting VA (PVA) 20/40 or worse in either eye. Chi-square, Fisher's exact test and multivariate logistic regression were used to assess factors associated with accuracy of vision screening. Level of significance was set at 5%. Trained teachers in Vietnam demonstrated 86.7% sensitivity, 95.7% specificity, 86.7% positive predictive value and 95.7% negative predictive value in identifying children with visual impairment using the UVA measurement. PVA measurement revealed low accuracy for teachers, which was significantly associated with child's age, sex, spectacle wear and myopic status, but UVA measurement showed no such associations. Better accuracy was achieved in measurement of VA and identification of children with visual impairment using UVA measurement compared to PVA. UVA measurement is recommended for teacher-based vision screening programs.

  6. Head impact exposure sustained by football players on days of diagnosed concussion.

    PubMed

    Beckwith, Jonathan G; Greenwald, Richard M; Chu, Jeffrey J; Crisco, Joseph J; Rowson, Steven; Duma, Stefan M; Broglio, Steven P; McAllister, Thomas W; Guskiewicz, Kevin M; Mihalik, Jason P; Anderson, Scott; Schnebel, Brock; Brolinson, P Gunnar; Collins, Michael W

    2013-04-01

    This study compares the frequency and severity of head impacts sustained by football players on days with and without diagnosed concussion and to identify the sensitivity and specificity of single-impact severity measures to diagnosed injury. One thousand two hundred eight players from eight collegiate football teams and six high school football teams wore instrumented helmets to measure head impacts during all team sessions, of which 95 players were diagnosed with concussion. Eight players sustained two injuries and one sustained three, providing 105 injury cases. Measures of head kinematics (peak linear and rotational acceleration, Gadd severity index, head injury criteria (HIC15), and change in head velocity (Δv)) and the number of head impacts sustained by individual players were compared between days with and without diagnosed concussion. Receiver operating characteristic curves were generated to evaluate the sensitivity and specificity of each kinematic measure to diagnosed concussion using only those impacts that directly preceded diagnosis. Players sustained a higher frequency of impacts and impacts with more severe kinematic properties on days of diagnosed concussion than on days without diagnosed concussion. Forty-five injury cases were immediately diagnosed after head impact. For these cases, peak linear acceleration and HIC15 were most sensitive to immediately diagnosed concussion (area under the curve = 0.983). Peak rotational acceleration was less sensitive to diagnosed injury than all other kinematic measures (P = 0.01), which are derived from linear acceleration (peak linear, HIC15, Gadd severity index, and Δv). Players sustained more impacts and impacts of higher severity on days of diagnosed concussion than on days without diagnosed concussion. In addition, of historical measures of impact severity, those associated with peak linear acceleration are the best predictors of immediately diagnosed concussion.

  7. Head Impact Exposure Sustained by Football Players on Days of Diagnosed Concussion

    PubMed Central

    Beckwith, Jonathan G.; Greenwald, Richard M.; Chu, Jeffrey J.; Crisco, Joseph J.; Rowson, Steven; Duma, Stefan M.; Broglio, Steven P.; McAllister, Thomas W.; Guskiewicz, Kevin M.; Mihalik, Jason P.; Anderson, Scott; Schnebel, Brock; Brolinson, P. Gunnar; Collins, Michael W.

    2012-01-01

    Purpose This study compares the frequency and severity of head impacts sustained by football players on days with and without diagnosed concussion and to identify the sensitivity and specificity of single impact severity measures to diagnosed injury. Methods 1,208 players from eight collegiate and six high school football teams wore instrumented helmets to measure head impacts during all team sessions, of which 95 players were diagnosed with concussion. Eight players sustained two injuries and one three, providing 105 injury cases. Measures of head kinematics (peak linear and rotational acceleration, Gadd Severity Index (GSI), Head Injury Criteria (HIC15), change in head velocity (Δv)) and the number of head impacts sustained by individual players were compared between days with and without diagnosed concussion. Receiver operator characteristic curves were generated to evaluate the sensitivity and specificity of each kinematic measure to diagnosed concussion using only those impacts that directly preceded diagnosis. Results Players sustained a higher frequency of impacts and impacts with more severe kinematic properties on days of diagnosed concussion than on days without diagnosed concussion. Forty-five injury cases were immediately diagnosed following head impact. For these cases, peak linear acceleration and HIC15 were most sensitive to immediately diagnosed concussion (AUC = 0.983). Peak rotational acceleration was less sensitive to diagnosed injury than all other kinematic measures (p = 0.01) which are derived from linear acceleration (peak linear, HIC15, GSI, and Δv). Conclusions Players sustain more impacts and impacts of higher severity on days of diagnosed concussion than on days without diagnosed concussion. Additionally, of historical measures of impact severity, those associated with peak linear acceleration are the best predictors of immediately diagnosed concussion. PMID:23135363

  8. Quantification of rapid environmental redox processes with quick-scanning x-ray absorption spectroscopy (Q-XAS)

    PubMed Central

    Ginder-Vogel, Matthew; Landrot, Gautier; Fischel, Jason S.; Sparks, Donald L.

    2009-01-01

    Quantification of the initial rates of environmental reactions at the mineral/water interface is a fundamental prerequisite to determining reaction mechanisms and contaminant transport modeling and predicting environmental risk. Until recently, experimental techniques with adequate time resolution and elemental sensitivity to measure initial rates of the wide variety of environmental reactions were quite limited. Techniques such as electron paramagnetic resonance and Fourier transform infrared spectroscopies suffer from limited elemental specificity and poor sensitivity to inorganic elements, respectively. Ex situ analysis of batch and stirred-flow systems provides high elemental sensitivity; however, their time resolution is inadequate to characterize rapid environmental reactions. Here we apply quick-scanning x-ray absorption spectroscopy (Q-XAS), at sub-second time-scales, to measure the initial oxidation rate of As(III) to As(V) by hydrous manganese(IV) oxide. Using Q-XAS, As(III) and As(V) concentrations were determined every 0.98 s in batch reactions. The initial apparent As(III) depletion rate constants (t < 30 s) measured with Q-XAS are nearly twice as large as rate constants measured with traditional analytical techniques. Our results demonstrate the importance of developing analytical techniques capable of analyzing environmental reactions on the same time scale as they occur. Given the high sensitivity, elemental specificity, and time resolution of Q-XAS, it has many potential applications. They could include measuring not only redox reactions but also dissolution/precipitation reactions, such as the formation and/or reductive dissolution of Fe(III) (hydr)oxides, solid-phase transformations (i.e., formation of layered-double hydroxide minerals), or almost any other reaction occurring in aqueous media that can be measured using x-ray absorption spectroscopy. PMID:19805269

  9. Sensitivity Kernels for the Cross-Convolution Measure: Eliminate the Source in Waveform Tomography

    NASA Astrophysics Data System (ADS)

    Menke, W. H.

    2017-12-01

    We use the adjoint method to derive sensitivity kernels for the cross-convolution measure, a goodness-of-fit criterion that is applicable to seismic data containing closely-spaced multiple arrivals, such as reverberating compressional waves and split shear waves. In addition to a general formulation, specific expressions for sensitivity with respect to density, Lamé parameter and shear modulus are derived for a isotropic elastic solid. As is typical of adjoint methods, the kernels depend upon an adjoint field, the source of which, in this case, is the reference displacement field, pre-multiplied by a matrix of cross-correlations of components of the observed field. We use a numerical simulation to evaluate the resolving power of a topographic inversion that employs the cross-convolution measure. The estimated resolving kernel shows is point-like, indicating that the cross-convolution measure will perform well in waveform tomography settings.

  10. Can MR Measurement of Renal Artery Flow and Renal Volume Predict the Outcome of Percutaneous Transluminal Renal Angioplasty?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Binkert, Christoph A.; Debatin, Jorg F.; Schneider, Ernst

    2001-07-15

    Purpose: Predicting therapeutic benefit from percutaneous transluminal renal angioplasty (PTRA) in patients with renal artery stenosis (RAS) remains difficult. This study investigates whether magnetic resonance (MR)-based renal artery flow measurements relative to renal parenchymal volume can predict clinical outcome following PTRA.Methods: The data on 23 patients (13 men, 10 women; age range 47-82 years, mean age 64 years) were analyzed. The indication for treatment was hypertension (n = 18) or renal insufficiency (n = 5). Thirty-four cases of RAS were identified: bilateral disease was manifest in 11 and unilateral disease in 12 patients. The MR imaging protocol included a breath-hold,more » cardiac-gated cine phase-contrast sequence for renal flow measurement and a fast multiplanar spoiled gradient-echo sequence for renal volume measurement. MR measurements were performed on the day prior to and the day following PTRA. Clinical success was defined as (a) a reduction in diastolic blood pressure > 15% or (b) a reduction in serum creatinine > 20%. Kidneys were categorized as normal volume or low volume. A renal flow index (RFI) was calculated by dividing the renal flow (ml/min) by the renal volume (cm{sup 3}).Results: Clinical success was observed in 11 patients. Twelve patients did not benefit from angioplasty. Normal kidney volume was seen in 10 of 11 responders and in 8 of 12 nonresponders, resulting in a sensitivity of 91%, specificity of 33%, a positive predictive value (PPV) of 56% and a negative predictive value (NPV) of 80%. A RFI below a threshold of 1.5 ml/min/cm{sup 3} predicted successful outcome with 100% sensitivity, 33% specificity, 58% PPV, and 100% NPV. The combination of normal renal volume and a RFI below 1.5 ml/min/cm{sup 3} identified PTRA responders with a sensitivity of 91%, a specificity of 67%, a PPV of 71%, and a NPV of 89%. PTRA resulted in a greater increase in renal flow in responders compared with nonresponders (p < 0.001).Conclusion: A combination of cine phase-contrast MR renal flow and parenchymal volume measurements enables identification of patients benefiting from PTRA with a high sensitivity and NPV, but only moderate specificity and PPV.« less

  11. Individual differences in children's global motion sensitivity correlate with TBSS-based measures of the superior longitudinal fasciculus.

    PubMed

    Braddick, Oliver; Atkinson, Janette; Akshoomoff, Natacha; Newman, Erik; Curley, Lauren B; Gonzalez, Marybel Robledo; Brown, Timothy; Dale, Anders; Jernigan, Terry

    2017-12-01

    Reduced global motion sensitivity, relative to global static form sensitivity, has been found in children with many neurodevelopmental disorders, leading to the "dorsal stream vulnerability" hypothesis (Braddick et al., 2003). Individual differences in typically developing children's global motion thresholds have been shown to be associated with variations in specific parietal cortical areas (Braddick et al., 2016). Here, in 125 children aged 5-12years, we relate individual differences in global motion and form coherence thresholds to fractional anisotropy (FA) in the superior longitudinal fasciculus (SLF), a major fibre tract communicating between parietal lobe and anterior cortical areas. We find a positive correlation between FA of the right SLF and individual children's sensitivity to global motion coherence, while FA of the left SLF shows a negative correlation. Further analysis of parietal cortical area data shows that this is also asymmetrical, showing a stronger association with global motion sensitivity in the left hemisphere. None of these associations hold for an analogous measure of global form sensitivity. We conclude that a complex pattern of structural asymmetry, including the parietal lobe and the superior longitudinal fasciculus, is specifically linked to the development of sensitivity to global visual motion. This pattern suggests that individual differences in motion sensitivity are primarily linked to parietal brain areas interacting with frontal systems in making decisions on integrated motion signals, rather than in the extra-striate visual areas that perform the initial integration. The basis of motion processing deficits in neurodevelopmental disorders may depend on these same structures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Brief assessment of food insecurity accurately identifies high-risk US adults.

    PubMed

    Gundersen, Craig; Engelhard, Emily E; Crumbaugh, Amy S; Seligman, Hilary K

    2017-06-01

    To facilitate the introduction of food insecurity screening into clinical settings, we examined the test performance of two-item screening questions for food insecurity against the US Department of Agriculture's Core Food Security Module. We examined sensitivity, specificity and accuracy of various two-item combinations of questions assessing food insecurity in the general population and high-risk population subgroups. 2013 Current Population Survey December Supplement, a population-based US survey. All survey participants from the general population and high-risk subgroups. The test characteristics of multiple two-item combinations of questions assessing food insecurity had adequate sensitivity (>97 %) and specificity (>70 %) for widespread adoption as clinical screening measures. We recommend two specific items for clinical screening programmes based on their widespread current use and high sensitivity for detecting food insecurity. These items query how often the household 'worried whether food would run out before we got money to buy more' and how often 'the food that we bought just didn't last and we didn't have money to get more'. The recommended items have sensitivity across high-risk population subgroups of ≥97 % and a specificity of ≥74 % for food insecurity.

  13. Differences between the prevalence of obesity and weight exceded estimated according to reported or direct measurement in adult people of Valencian Region

    PubMed

    Jiménez-Talamantes, Raquel; Rizk Hernández, Jennifer; Quiles Izquierdo, Joan

    2017-02-01

    Introduction: The assessment of obesity in health surveys includes the study of the physical characteristics of human body. Anthropometrical dates can be obtained by measurement or by interview. According the method that we were used we can estimate different values for frequencies of this problem. Objectives: Measure the discrepancies of the frequency of obesity and overweight estimated with data of height and weight obtained by interview respect to those measured in a population survey. Methods: Cross-sectional survey of a sample of 1,153 adult subjects, where height and weight data reported and measured were compared by Pearson correlation. It was estimated the prevalence of obesity and overweight by two methods and we calculated the Kappa’s index, the sensitivity and specifi city for to define the predictive capacity of reported data. Results: The values of weight, height and BMI by declared and measured data presented a correlation of 0.96, 0.93 and 0.91, respectively. The prevalence of obesity was 16.4% with declared data and 23.3% for measured data (kappa = 0.68), sensitivity 63.2% and specifi city 97.9%. The prevalence of excess of weight was 51.4% with declared data and 61.1% for measured data (kappa = 0.73), sensitivity 81.3% and specificity 95.3%. These differences were statistically signifi cant. Conclusions: There is an underestimation of the prevalence of obesity and excess of weight in populations when anthropometric data were used but in good agreement and specificity was found when measured data are used.

  14. Questionnaire Predictors of Atopy in a US Population Sample: Findings From the National Health and Nutrition Examination Survey, 2005–2006

    PubMed Central

    Hoppin, Jane A.; Jaramillo, Renee; Salo, Paivi; Sandler, Dale P.; London, Stephanie J.; Zeldin, Darryl C.

    2011-01-01

    Allergic conditions and biochemical measures are both used to characterize atopy. To assess questionnaires’ ability to predict biochemical measures of atopy, the authors used data on 5 allergic conditions (allergy, hay fever, eczema, rhinitis, and itchy rash) and serum-specific immunoglobulin E (IgE) levels from the 2005–2006 National Health and Nutrition Examination Survey. Atopy was defined as 1 or more positive specific IgEs (≥0.35 kU/L). Questionnaire responses were assessed for sensitivity, specificity, and positive and negative predictive values for atopy. In this population-based US sample, 44% of participants were specific IgE-positive and 53% reported at least 1 allergic condition. Discordance between atopy and allergic conditions was considerable; 37% of persons with atopy reported no allergic condition, and 48% of persons who reported an allergic condition were not atopic. Thus, no combination of self-reported allergic conditions achieved both high sensitivity and high specificity for IgE. The positive predictive value of reported allergic conditions for atopy ranged from 50% for eczema to 72% for hay fever, while the negative predictive value ranged from 57% for eczema to 65% for any condition. Given the high proportion of asymptomatic participants who were specific IgE-positive and persons who reported allergic conditions but were specific IgE-negative, it is unlikely that questionnaires will ever capture the same participants as those found to be atopic by biochemical measures. PMID:21273397

  15. Accuracy of body mass index in volunteer firefighters.

    PubMed

    Ode, J; Knous, J; Schlaff, R; Hemenway, J; Peterson, J; Lowry, J

    2014-04-01

    Obesity is prevalent among career firefighters and may contribute to heart attacks, a leading cause of on-duty fatalities. The US National Fire Protection Association estimates that 800 000 of 1.1 million firefighters are volunteers. Body mass index (BMI) is commonly used to assess obesity, but little is known about its accuracy in volunteer firefighters, in whom muscle mass may be higher, given firefighting's physical demands, reducing its accuracy in identifying obesity. To evaluate the accuracy of BMI in identifying obese volunteer firefighters. Height, weight and body composition were measured in 73 male volunteer firefighters (mean age 40±12). The proportions with BMI ≥ 25kg/m(2), ≥30kg/ m(2) and percent fat ≤ 20th percentile were determined. Using the age-specific 20th percentile for percent fat (Cooper Clinic) as the criterion for being over-fat, the accuracy of BMI was assessed using sensitivity and specificity calculations. The means ± standard deviation of BMI and percent fat were 32±6 and 25±5, respectively. The proportions with a BMI ≥ 25 and ≥30 were 90% and 60%, respectively. Fifty-one percent had a percent fat ≤ 20th percentile. The measure BMI ≥ 25 had a perfect sensitivity (1.0) and low specificity (0.19) and BMI ≥ 30 had a high sensitivity (0.89) and moderate specificity (0.69). Although BMI ≥ 30 accurately predicted being over-fat, it misclassified large and lean firefighters. Although BMI should be used cautiously, it can identify over-fat firefighters at risk of cardiovascular disease, and its measurement is cost-effective and simple.

  16. Value of high-sensitivity C-reactive protein assays in predicting atrial fibrillation recurrence: a systematic review and meta-analysis.

    PubMed

    Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang

    2014-02-20

    We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Systematic review and meta-analysis. PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion.

  17. Addressing the Analytic Challenges of Cross-Sectional Pediatric Pneumonia Etiology Data.

    PubMed

    Hammitt, Laura L; Feikin, Daniel R; Scott, J Anthony G; Zeger, Scott L; Murdoch, David R; O'Brien, Katherine L; Deloria Knoll, Maria

    2017-06-15

    Despite tremendous advances in diagnostic laboratory technology, identifying the pathogen(s) causing pneumonia remains challenging because the infected lung tissue cannot usually be sampled for testing. Consequently, to obtain information about pneumonia etiology, clinicians and researchers test specimens distant to the site of infection. These tests may lack sensitivity (eg, blood culture, which is only positive in a small proportion of children with pneumonia) and/or specificity (eg, detection of pathogens in upper respiratory tract specimens, which may indicate asymptomatic carriage or a less severe syndrome, such as upper respiratory infection). While highly sensitive nucleic acid detection methods and testing of multiple specimens improve sensitivity, multiple pathogens are often detected and this adds complexity to the interpretation as the etiologic significance of results may be unclear (ie, the pneumonia may be caused by none, one, some, or all of the pathogens detected). Some of these challenges can be addressed by adjusting positivity rates to account for poor sensitivity or incorporating test results from controls without pneumonia to account for poor specificity. However, no classical analytic methods can account for measurement error (ie, sensitivity and specificity) for multiple specimen types and integrate the results of measurements for multiple pathogens to produce an accurate understanding of etiology. We describe the major analytic challenges in determining pneumonia etiology and review how the common analytical approaches (eg, descriptive, case-control, attributable fraction, latent class analysis) address some but not all challenges. We demonstrate how these limitations necessitate a new, integrated analytical approach to pneumonia etiology data. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  18. Cytokeratin-18 in Diagnosis of HCC in Patients with Liver Cirrhosis

    PubMed

    Ismail, Saber A; El Saadany, Sherif; Ziada, Dina H; Zakaria, Soha S; Mayah, Wael W; Elashry, Heba; Arafa, Mona; Elmashad, Nehal

    2017-04-01

    Background: Hepatocellular carcinoma (HCC) is a common malignancy that occurs secondary to viral hepatitis B and C cirrhosis under the influence of environmental factors. In early stages, clinical diagnosis is often difficult and distinguishing HCC from cirrhosis and other hepatic masses by conventional tests is frequently not feasible. Physicians usually depend on measuring serum alpha-fetoprotein (AFP), but this marker has low sensitivity and specificity. The aim of this research was to determine any role of serum cytokeratin-18(Ck-18) as a marker for diagnosis of HCC in patients with liver cirrhosis. Patients and methods: We used ELISA to measure the serum levels of AFP and CK 18 in 60 Egyptian patients (30 cirrhotic and 30 with HCC) and 30 controls. Results: The Ck-18 level was significantly elevated in the HCC group (1247.8± 105.3U/L) when compared to the liver cirrhosis (834.1± 38.8 U/L) and control groups (265.2±83.1U/L). Ck-18 as a marker showed 95.6% sensitivity, 93.3% specificity and 98.8% accuracy. The mean serum AFP was 4901.4±2185.8ng/ml in the HCC group, 100.7±71.7 ng/ml in the cirrhotic group, and 4.0±1.2ng/ ml in controls. AFP showed 55. 7% sensitivity, 97. 7% specificity and 84.4% accuracy. Combined use of both Ck-18 and AFP improved the sensitivity to 98%. Conclusion: Serum cytokeratin-18 level can be used as a diagnostic biomarker for HCC with a higher sensitivity than AFP. Creative Commons Attribution License

  19. Cytokeratin-18 in Diagnosis of HCC in Patients with Liver Cirrhosis

    PubMed Central

    Ismail, Saber A; Saadany, Sherif El; Ziada, Dina H; Zakaria, Soha S; Mayah, Wael W; Elashry, Heba; Arafa, Mona; Elmashad, Nehal

    2017-01-01

    Background: Hepatocellular carcinoma (HCC) is a common malignancy that occurs secondary to viral hepatitis B and C cirrhosis under the influence of environmental factors. In early stages, clinical diagnosis is often difficult and distinguishing HCC from cirrhosis and other hepatic masses by conventional tests is frequently not feasible. Physicians usually depend on measuring serum alpha-fetoprotein (AFP), but this marker has low sensitivity and specificity. The aim of this research was to determine any role of serum cytokeratin-18(Ck-18) as a marker for diagnosis of HCC in patients with liver cirrhosis. Patients and methods: We used ELISA to measure the serum levels of AFP and CK 18 in 60 Egyptian patients (30 cirrhotic and 30 with HCC) and 30 controls. Results: The Ck-18 level was significantly elevated in the HCC group (1247.8± 105.3U/L) when compared to the liver cirrhosis (834.1± 38.8 U/L) and control groups (265.2±83.1U/L). Ck-18 as a marker showed 95.6% sensitivity, 93.3% specificity and 98.8% accuracy. The mean serum AFP was 4901.4±2185.8ng/ml in the HCC group, 100.7±71.7 ng/ml in the cirrhotic group, and 4.0±1.2ng/ml in controls. AFP showed 55. 7% sensitivity, 97. 7% specificity and 84.4% accuracy. Combined use of both Ck-18 and AFP improved the sensitivity to 98%. Conclusion: Serum cytokeratin-18 level can be used as a diagnostic biomarker for HCC with a higher sensitivity than AFP. PMID:28547948

  20. Addressing the Analytic Challenges of Cross-Sectional Pediatric Pneumonia Etiology Data

    PubMed Central

    Feikin, Daniel R.; Scott, J. Anthony G.; Zeger, Scott L.; Murdoch, David R.; O’Brien, Katherine L.; Deloria Knoll, Maria

    2017-01-01

    Abstract Despite tremendous advances in diagnostic laboratory technology, identifying the pathogen(s) causing pneumonia remains challenging because the infected lung tissue cannot usually be sampled for testing. Consequently, to obtain information about pneumonia etiology, clinicians and researchers test specimens distant to the site of infection. These tests may lack sensitivity (eg, blood culture, which is only positive in a small proportion of children with pneumonia) and/or specificity (eg, detection of pathogens in upper respiratory tract specimens, which may indicate asymptomatic carriage or a less severe syndrome, such as upper respiratory infection). While highly sensitive nucleic acid detection methods and testing of multiple specimens improve sensitivity, multiple pathogens are often detected and this adds complexity to the interpretation as the etiologic significance of results may be unclear (ie, the pneumonia may be caused by none, one, some, or all of the pathogens detected). Some of these challenges can be addressed by adjusting positivity rates to account for poor sensitivity or incorporating test results from controls without pneumonia to account for poor specificity. However, no classical analytic methods can account for measurement error (ie, sensitivity and specificity) for multiple specimen types and integrate the results of measurements for multiple pathogens to produce an accurate understanding of etiology. We describe the major analytic challenges in determining pneumonia etiology and review how the common analytical approaches (eg, descriptive, case-control, attributable fraction, latent class analysis) address some but not all challenges. We demonstrate how these limitations necessitate a new, integrated analytical approach to pneumonia etiology data. PMID:28575372

  1. Significance of serum total prostate specific antigen and digital rectal examination in the diagnosis of prostate cancer.

    PubMed

    Abdrabo, Abdelkarim A; Fadlalla, Adil I; Fadl-Elmula, Imad M

    2011-11-01

    To assess the significance of serum total prostate specific antigen (tPSA) and digital rectal examination (DRE) in the diagnosis of prostate cancer (PC). One hundred and eighteen patients with serum tPSA ranging between 2.5 and 10 ng/ml with lower urinary tract symptoms presented at the Urology Clinic of Soba University Hospital, Khartoum, Sudan from August 2008 and January 2010 were included in the study. Serum tPSA was measured using enzyme immunoassay method, and accordingly, the patients were classified into 2 groups: patients that had tPSA between 2.5-4.0 ng/ml; and patients that had tPSA between 4.1-10 ng/ml. The DRE was performed on all patients by a qualified urologist, and were recorded as a group with suspicion of PC, and a group with no suspicion of PC. All patients underwent transrectal sextant prostate biopsy. The DRE alone showed 63.8% sensitivity and 68% specificity with 46.9% positive predictive value (PPV) for the diagnosis of PC. The tPSA test revealed 91.6% sensitivity and 24% specificity with PPV of 34%. However, when combining DRE and tPSA, the sensitivity reached 100% and the specificity increased to 92% with PPV of 49%. Combining DRE and tPSA test increases the sensitivity, specificity, and PPV of PC detection.

  2. Incremental Validity in the Clinical Assessment of Early Childhood Development

    ERIC Educational Resources Information Center

    Liu, Xin; Zhou, Xiaobin; Lackaff, Julie

    2013-01-01

    The authors demonstrate the increment of clinical validity in early childhood assessment of physical impairment (PI), developmental delay (DD), and autism (AUT) using multiple standardized developmental screening measures such as performance measures and parent and teacher rating scales. Hierarchical regression and sensitivity/specificity analyses…

  3. Variation in Patients’ Awareness of CKD according to How They Are Asked

    PubMed Central

    Zhu, Yunnuo; Velasquez, Alexandra; Espinoza, Juan; Mendez, C. Damaris; Banerjee, Tanushree; Hsu, Chi-yuan; Powe, Neil R.

    2016-01-01

    Background and objectives Awareness of CKD is necessary for patient engagement and adherence to medical regimens. Having an accurate tool to assess awareness is important. Use of the National Health and Nutrition Examination Survey (NHANES) CKD awareness question “Have you ever been told by a doctor or other health professional that you had weak or failing kidneys (excluding kidney stones, bladder infections, or incontinence)?” produces surprisingly low measures of CKD awareness. We sought to compare the sensitivity and specificity of different questions ascertaining awareness of CKD and other health conditions. Design, setting, participants, & measurements Between August of 2011 and August of 2014, an in-person questionnaire was administered to 220 adults with CKD, diabetes, hypertension, or hyperlipidemia who received primary care in a public health care delivery system to ascertain awareness of each condition. CKD awareness was measured using the NHANES question, and other questions, asking if patients knew about their “kidney disease”, “protein in the urine”, “kidney problem”, or “kidney damage.” Demographic data were self-reported; health literacy was measured. The sensitivity and specificity of each question was calculated using the medical record as the gold standard. Results In this diverse population (9.6% white, 40.6% black, 36.5% Hispanic, 12.3% Asian), the mean age was 58 years, 30% had a non-English language preference, and 45% had low health literacy. Eighty percent of participants had CKD, with a mean eGFR of 47.2 ml/min per 1.73 m2. The sensitivities of each CKD awareness question were: 26.4% for “kidney damage”, 27.7% for “kidney disease”, 33.2% for “weak or failing kidneys”, 39.8% for “protein in the urine”, and 40.1% for “kidney problem.” Specificities ranged from 82.2% to 97.6%. The best two-question combination yielded a sensitivity of 53.1% and a specificity of 83.3%. This was lower than awareness of hypertension (90.1%) or diabetes (91.8%). Conclusions CKD awareness is low compared with other chronic diseases regardless of how it is ascertained. Nevertheless, more sensitive questions to ascertain CKD awareness suggest current under-ascertainment. PMID:27340288

  4. Intrauterine sensitization of allergen-specific IgE analyzed by a highly sensitive new allergen microarray.

    PubMed

    Kamemura, Norio; Tada, Hitomi; Shimojo, Naoki; Morita, Yoshinori; Kohno, Yoichi; Ichioka, Takao; Suzuki, Koichi; Kubota, Kenji; Hiyoshi, Mineyoshi; Kido, Hiroshi

    2012-07-01

    To design a rational allergy prevention program, it is important to determine whether allergic sensitization starts in utero under the maternal immune system. To investigate the origin of allergen-specific IgE antibodies in cord blood (CB) and maternofetal transfer of immunoglobulins. The levels of food and inhalant allergen-specific IgE, IgA, IgG, and IgG(4) antibodies in CB and maternal blood (MB) from 92 paired neonates and mothers were measured by using a novel allergen microarray of diamond-like-carbon-coated chip, with high-sensitivity detection of allergen-specific antibodies and allergen profiles. The levels of allergen-specific IgE antibodies against food and inhalant allergens and allergen profiles were identical in CB and newborn blood, but the levels and profiles, specifically against inhalant allergens, were different from those in MB. The level of allergen-specific IgA antibodies was below the detection levels in CB despite clear detection in MB. Therefore, contamination with MB in CB was excluded on the basis of extremely low levels of IgA antibodies in CB and the obvious mismatch of the allergen-specific IgE and IgA profiles between CB and MB. However, the levels of allergen-specific IgG and IgG(4) antibodies and their allergen profiles were almost identical in both MB and CB. Allergen-specific levels of IgE and IgA antibodies and their allergen profiles analyzed by the diamond-like-carbon allergen chip indicate that IgE antibodies in CB are of fetal origin. Food-allergen specific IgE antibodies were detected more often than inhalant-allergen specific IgE antibodies in CB, the reason of which remains unclarified. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  5. Determination of the optimum-size californium-252 neutron source for borehole capture gamma-ray analysis

    USGS Publications Warehouse

    Senftle, F.E.; Macy, R.J.; Mikesell, J.L.

    1979-01-01

    The fast- and thermal-neutron fluence rates from a 3.7 ??g 252Cf neutron source in a simulated borehole have been measured as a function of the source-to-detector distance using air, water, coal, iron ore-concrete mix, and dry sand as borehole media. Gamma-ray intensity measurements were made for specific spectral lines at low and high energies for the same range of source-to-detector distances in the iron ore-concrete mix and in coal. Integral gamma-ray counts across the entire spectrum were also made at each source-to-detector distance. From these data, the specific neutron-damage rate, and the critical count-rate criteria, we show that in an iron ore-concrete mix (low hydrogen concentration), 252Cf neutron sources of 2-40 ??g are suitable. The source size required for optimum gamma-ray sensitivity depends on the energy of the gamma ray being measured. In a hydrogeneous medium such as coal, similar measurements were made. The results show that sources from 2 to 20 ??g are suitable to obtain the highest gamma-ray sensitivity, again depending on the energy of the gamma ray being measured. In a hydrogeneous medium, significant improvement in sensitivity can be achieved by using faster electronics; in iron ore, it cannot. ?? 1979 North-Holland Publishing Co.

  6. Commissioning a p-type silicon diode for use in clinical electron beams.

    PubMed

    Eveling, J N; Morgan, A M; Pitchford, W G

    1999-01-01

    Commissioning measurements were carried out on a p-type silicon diode detector for use in patient monitoring in high energy electron beams. Characteristics specific to the diode were examined. The variation in diode sensitivity with dose per pulse was found to be less than 1% over a range 0.069-0.237 mGy/pulse. The diode exhibited a sensitivity variation with accumulated dose of 10% per kGy and a sensitivity variation with surface temperature of 0.26%/degree C. The dependence of the diode response on the direction of the incident electron beam was investigated. Results were found to exceed the manufacturer's specifications. Output factors measured with the diode agree to within 1.5% of those measured with an NACP-02 air ionization chamber. The detector showed a variation in response with energy of 0.8% over the energy range 4-15 MeV. Prior to introducing the diode into clinical use, an assessment of beam perturbation directly behind the diode was made. The maximum reduction in local dose directly behind the diode at a depth of 1.0 cm below the surface was approximately 13% at 4 and 15 MeV.

  7. An investigation of new toxicity test method performance in validation studies: 1. Toxicity test methods that have predictive capacity no greater than chance.

    PubMed

    Bruner, L H; Carr, G J; Harbell, J W; Curren, R D

    2002-06-01

    An approach commonly used to measure new toxicity test method (NTM) performance in validation studies is to divide toxicity results into positive and negative classifications, and the identify true positive (TP), true negative (TN), false positive (FP) and false negative (FN) results. After this step is completed, the contingent probability statistics (CPS), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) are calculated. Although these statistics are widely used and often the only statistics used to assess the performance of toxicity test methods, there is little specific guidance in the validation literature on what values for these statistics indicate adequate performance. The purpose of this study was to begin developing data-based answers to this question by characterizing the CPS obtained from an NTM whose data have a completely random association with a reference test method (RTM). Determining the CPS of this worst-case scenario is useful because it provides a lower baseline from which the performance of an NTM can be judged in future validation studies. It also provides an indication of relationships in the CPS that help identify random or near-random relationships in the data. The results from this study of randomly associated tests show that the values obtained for the statistics vary significantly depending on the cut-offs chosen, that high values can be obtained for individual statistics, and that the different measures cannot be considered independently when evaluating the performance of an NTM. When the association between results of an NTM and RTM is random the sum of the complementary pairs of statistics (sensitivity + specificity, NPV + PPV) is approximately 1, and the prevalence (i.e., the proportion of toxic chemicals in the population of chemicals) and PPV are equal. Given that combinations of high sensitivity-low specificity or low specificity-high sensitivity (i.e., the sum of the sensitivity and specificity equal to approximately 1) indicate lack of predictive capacity, an NTM having these performance characteristics should be considered no better for predicting toxicity than by chance alone.

  8. Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma.

    PubMed

    Rao, Harsha L; Kadambi, Sujatha V; Weinreb, Robert N; Puttaiah, Narendra K; Pradhan, Zia S; Rao, Dhanaraj A S; Kumar, Rajesh S; Webers, Carroll A B; Shetty, Rohit

    2017-08-01

    To evaluate the diagnostic ability of peripapillary vessel density measurements on optical coherence tomography angiography (OCTA) in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG), and to compare these with peripapillary retinal nerve fibre layer (RNFL) thickness measurements. In a cross-sectional study, 48 eyes of 33 healthy control subjects, 63 eyes of 39 patients with POAG and 49 eyes of 32 patients with PACG underwent OCTA (RTVue-XR, Optovue, Fremont, California, USA) and RNFL imaging with spectral domain OCT. Diagnostic abilities of vessel density and RNFL parameters were evaluated using area under receiver operating characteristic curves (AUC) and sensitivities at fixed specificities. AUCs of peripapillary vessel density ranged between 0.48 for the temporal sector and 0.88 for the inferotemporal sector in POAG. The same in PACG ranged between 0.57 and 0.86. Sensitivities at 95% specificity ranged from 13% to 70% in POAG, and from 10% to 67% in PACG. AUCs of peripapillary RNFL thickness ranged between 0.51 for the temporal sector and 0.91 for the inferonasal sector in POAG. The same in PACG ranged between 0.61 and 0.87. Sensitivities at 95% specificity ranged from 8% to 68% in POAG, and from 2% to 67% in PACG. AUCs of all peripapillary vessel density measurements were comparable (p>0.05) to the corresponding RNFL thickness measurements in both POAG and PACG. Diagnostic ability of peripapillary vessel density parameters of OCTA, especially the inferotemporal sector measurement, was good in POAG and PACG. Diagnostic abilities of vessel density measurements were comparable to RNFL measurements in both POAG and PACG. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Analytical Validation of Accelerator Mass Spectrometry for Pharmaceutical Development: the Measurement of Carbon-14 Isotope Ratio.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keck, B D; Ognibene, T; Vogel, J S

    2010-02-05

    Accelerator mass spectrometry (AMS) is an isotope based measurement technology that utilizes carbon-14 labeled compounds in the pharmaceutical development process to measure compounds at very low concentrations, empowers microdosing as an investigational tool, and extends the utility of {sup 14}C labeled compounds to dramatically lower levels. It is a form of isotope ratio mass spectrometry that can provide either measurements of total compound equivalents or, when coupled to separation technology such as chromatography, quantitation of specific compounds. The properties of AMS as a measurement technique are investigated here, and the parameters of method validation are shown. AMS, independent of anymore » separation technique to which it may be coupled, is shown to be accurate, linear, precise, and robust. As the sensitivity and universality of AMS is constantly being explored and expanded, this work underpins many areas of pharmaceutical development including drug metabolism as well as absorption, distribution and excretion of pharmaceutical compounds as a fundamental step in drug development. The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of {sup 14}C/C ratio, independent of chemical separation procedures. The isotope ratio measurement was specific (owing to the {sup 14}C label), stable across samples storage conditions for at least one year, linear over 4 orders of magnitude with an analytical range from one tenth Modern to at least 2000 Modern (instrument specific). Further, accuracy was excellent between 1 and 3 percent while precision expressed as coefficient of variation is between 1 and 6% determined primarily by radiocarbon content and the time spent analyzing a sample. Sensitivity, expressed as LOD and LLOQ was 1 and 10 attomoles of carbon-14 (which can be expressed as compound equivalents) and for a typical small molecule labeled at 10% incorporated with {sup 14}C corresponds to 30 fg equivalents. AMS provides an sensitive, accurate and precise method of measuring drug compounds in biological matrices.« less

  10. Performance of C-reactive protein and procalcitonin to distinguish viral from bacterial and malarial causes of fever in Southeast Asia.

    PubMed

    Lubell, Yoel; Blacksell, Stuart D; Dunachie, Susanna; Tanganuchitcharnchai, Ampai; Althaus, Thomas; Watthanaworawit, Wanitda; Paris, Daniel H; Mayxay, Mayfong; Peto, Thomas J; Dondorp, Arjen M; White, Nicholas J; Day, Nicholas P J; Nosten, François; Newton, Paul N; Turner, Paul

    2015-11-11

    Poor targeting of antimicrobial drugs contributes to the millions of deaths each year from malaria, pneumonia, and other tropical infectious diseases. While malaria rapid diagnostic tests have improved use of antimalarial drugs, there are no similar tests to guide the use of antibiotics in undifferentiated fevers. In this study we estimate the diagnostic accuracy of two well established biomarkers of bacterial infection, procalcitonin and C-reactive protein (CRP) in discriminating between common viral and bacterial infections in malaria endemic settings of Southeast Asia. Serum procalcitonin and CRP levels were measured in stored serum samples from febrile patients enrolled in three prospective studies conducted in Cambodia, Laos and, Thailand. Of the 1372 patients with a microbiologically confirmed diagnosis, 1105 had a single viral, bacterial or malarial infection. Procalcitonin and CRP levels were compared amongst these aetiological groups and their sensitivity and specificity in distinguishing bacterial infections and bacteraemias from viral infections were estimated using standard thresholds. Serum concentrations of both biomarkers were significantly higher in bacterial infections and malaria than in viral infections. The AUROC for CRP in discriminating between bacterial and viral infections was 0.83 (0.81-0.86) compared with 0.74 (0.71-0.77) for procalcitonin (p < 0.0001). This relative advantage was evident in all sites and when stratifying patients by age and admission status. For CRP at a threshold of 10 mg/L, the sensitivity of detecting bacterial infections was 95% with a specificity of 49%. At a threshold of 20 mg/L sensitivity was 86% with a specificity of 67%. For procalcitonin at a low threshold of 0.1 ng/mL the sensitivity was 90% with a specificity of 39%. At a higher threshold of 0.5 ng/ul sensitivity was 60% with a specificity of 76%. In samples from febrile patients with mono-infections from rural settings in Southeast Asia, CRP was a highly sensitive and moderately specific biomarker for discriminating between viral and bacterial infections. Use of a CRP rapid test in peripheral health settings could potentially be a simple and affordable measure to better identify patients in need of antibacterial treatment and part of a global strategy to combat the emergence of antibiotic resistance.

  11. Imaging outcomes for trials of remyelination in multiple sclerosis.

    PubMed

    Mallik, Shahrukh; Samson, Rebecca S; Wheeler-Kingshott, Claudia A M; Miller, David H

    2014-12-01

    Trials of potential neuroreparative agents are becoming more important in the spectrum of multiple sclerosis research. Appropriate imaging outcomes are required that are feasible from a time and practicality point of view, as well as being sensitive and specific to myelin, while also being reproducible and clinically meaningful. Conventional MRI sequences have limited specificity for myelination. We evaluate the imaging modalities which are potentially more specific to myelin content in vivo, such as magnetisation transfer ratio (MTR), restricted proton fraction f (from quantitative magnetisation transfer measurements), myelin water fraction and diffusion tensor imaging (DTI) metrics, in addition to positron emission tomography (PET) imaging. Although most imaging applications to date have focused on the brain, we also consider measures with the potential to detect remyelination in the spinal cord and in the optic nerve. At present, MTR and DTI measures probably offer the most realistic and feasible outcome measures for such trials, especially in the brain. However, no one measure currently demonstrates sufficiently high sensitivity or specificity to myelin, or correlation with clinical features, and it should be useful to employ more than one outcome to maximise understanding and interpretation of findings with these sequences. PET may be less feasible for current and near-future trials, but is a promising technique because of its specificity. In the optic nerve, visual evoked potentials can indicate demyelination and should be correlated with an imaging outcome (such as optic nerve MTR), as well as clinical measures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. [Enzymatic methods in the analysis of musts and wines].

    PubMed

    Lafon-Lafourcade, S

    1978-01-01

    The enzymatic methods are based on the property of the enzymes to catalyse specifically and reversibly the conversion of certain metabolites. These methods, developed thanks to the industrial preparation of enzymes, can be applied with no major modification to the analysis of drinks. About 15 constituants of musts and wines can now be determined by these methods. If their cost price was not relatively high, their specificity, sensitivity and rapidity would enable them to compete with the most precise of chemical methods. This is why they are only used in analytic oenology when chemical analysis is most specific enough or too laborious. Enzymatic measurement allows one by its specificity to determine the amount of residual sugar that is fermentable in a dry wine and by its sensitivity to verifie the total disappearance of the malic acid of the wine. Its rapidity must make it preferable to the long and not very specific chemical measurement, especially concerning the determination of citric acid. But glycerol, ethanol and acetic acid can be measured by chemical or chromatographical means with sufficient precision and for a more modest price. In oenology the methods are essentially used for research. They have permitted the study of the combinations of sulphur anhydride in wines (measurement of cetonic acids). The determination of the isomeric nature of the lactic acid produced from sugars by lactic bacteria is based on their application; this determination is a criterium for the identification and classification of these microorganisms. The measurement of the lactic acid during vinification allows the early disclosure of the first effects of a bacterial development; inversely it permits the invalidation of the existence of a lactic sourness, which a high volatile acidity might point to. Lastly, the enzymatic measurement of gluconic acid allows the health of the crop to be controlled.

  13. [Sensitivity and specificity between the Composite International Diagnostic Interview Version 3.0 (World Mental Health, CIDI) and the Standardised Clinical Evaluation version I (SCID-I) in a mental health survey of the city of Medellin, 2012].

    PubMed

    Montoya Gonzalez, Laura Elisa; Restrepo Bernal, Diana Patricia; Mejía-Montoya, Roberto; Bareño-Silva, José; Sierra-Hincapié, Gloria; Torres de Galvis, Yolanda; Marulanda-Restrepo, Daniel; Gómez-Sierra, Natalia; Gaviria-Arbeláez, Silvia

    2016-01-01

    In order to address the mental health problems of the Colombian population it is necessary to have diagnostic tools (local and international) that are valid, easy to apply, and comparable. To compare the sensitivity and specificity between the CIDI 3.0 and the SCID-I for major depressive disorder, bipolar I and II disorder, and substance dependence disorder. Cross-sectional study comparing the life prevalence of three mental disorders in 100 subjects using the CIDI 3.0 and the SCID-I. The study was approved by the Institutional Ethics Committee. The two diagnostic interviews were performed that measured by sensitivity, specificity, positive predictive value and negative predictive value with confidence intervals of 95%. The SPSS version 21.0 software was used for data analysis. The median age was 43.5 years, with an interquartile interval of 30 years. The highest sensitivity (Se) and specificity (Sp) was observed for drug dependence diagnosis - with 80%, (95%CI, 34.94-100), and 98.46 (95%CI, 94.7-100), respectively. SCID-I and CIDI 3.0 showed different levels of sensitivity and specificity for the three disorders studied with: high for substance dependence disorder, moderate for bipolar disorder I and II, and low for major depressive disorder. Copyright © 2015 Asociación Colombiana de Psiquiatría. All rights reserved.

  14. Diagnostic value of sputum adenosine deaminase (ADA) level in pulmonary tuberculosis.

    PubMed

    Binesh, Fariba; Jalali, Hadi; Zare, Mohammad Reza; Behravan, Farhad; Tafti, Arefeh Dehghani; Behnaz, Fatemah; Tabatabaee, Mohammad; Shahcheraghi, Seyed Hossein

    2016-06-01

    Tuberculosis is still a considerable health problem in many countries. Rapid diagnosis of this disease is important, and adenosine deaminase (ADA) has been used as a diagnostic test. The aim of this study was to assess the diagnostic value of ADA in the sputum of patients with pulmonary tuberculosis. The current study included 40 patients with pulmonary tuberculosis (culture positive, smear ±) and 42 patients with non tuberculosis pulmonary diseases (culture negative). ADA was measured on all of the samples. The median value of ADA in non-tuberculosis patients was 2.94 (4.2) U/L and 4.01 (6.54) U/L in tuberculosis patients, but this difference was not statistically significant (p=0.100). The cut-off point of 3.1 U/L had a sensitivity of 61% and a specificity of 53%, the cut-off point of 2.81 U/L had a sensitivity of 64% and a specificity of 50% and the cut-off point of 2.78 U/L had a sensitivity of 65% and a specificity of 48%. The positive predictive values for cut-off points of 3.1, 2.81 and 2.78 U/L were 55.7%, 57.44% and 69.23%, respectively. The negative predictive values for the abovementioned cut-off points were 56.75%, 57.14% and 55.88%, respectively. Our results showed that sputum ADA test is neither specific nor sensitive. Because of its low sensitivity and specificity, determination of sputum ADA for the diagnosis of pulmonary tuberculosis is not recommended.

  15. Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy

    NASA Astrophysics Data System (ADS)

    Gueth, P.; Dauvergne, D.; Freud, N.; Létang, J. M.; Ray, C.; Testa, E.; Sarrut, D.

    2013-07-01

    Online dose monitoring in proton therapy is currently being investigated with prompt-gamma (PG) devices. PG emission was shown to be correlated with dose deposition. This relationship is mostly unknown under real conditions. We propose a machine learning approach based on simulations to create optimized treatment-specific classifiers that detect discrepancies between planned and delivered dose. Simulations were performed with the Monte-Carlo platform Gate/Geant4 for a spot-scanning proton therapy treatment and a PG camera prototype currently under investigation. The method first builds a learning set of perturbed situations corresponding to a range of patient translation. This set is then used to train a combined classifier using distal falloff and registered correlation measures. Classifier performances were evaluated using receiver operating characteristic curves and maximum associated specificity and sensitivity. A leave-one-out study showed that it is possible to detect discrepancies of 5 mm with specificity and sensitivity of 85% whereas using only distal falloff decreases the sensitivity down to 77% on the same data set. The proposed method could help to evaluate performance and to optimize the design of PG monitoring devices. It is generic: other learning sets of deviations, other measures and other types of classifiers could be studied to potentially reach better performance. At the moment, the main limitation lies in the computation time needed to perform the simulations.

  16. Measurement of the ankle brachial index with a non-mercury sphygmomanometer in diabetic patients: a concordance study

    PubMed Central

    2013-01-01

    Background The removal of mercury sphygmomanometers from health centers requires the validation of other instruments to measure blood pressure in the limbs to calculate the ankle-brachial index (ABI). Methods Descriptive cross-sectional study of agreement between two measurement methods in type 2 diabetes patients from three urban primary healthcare centres in the Barcelonès Nord i Maresme area (Catalonia, Spain). ABI was determined with Doppler and mercury sphygmomanometer and Doppler and the “hybrid” sphygmomanometer OMRON HEM-907 model. Agreement was evaluated using the weighted kappa index. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated using the mercury sphygmomanometer as the gold standard. Results 211 patients were included, from these, 421 limbs were available for study. The mean age of the participants was 67 years (SD = 10), 51.7% were women. The index of agreement between ABI measured with a mercury sphygmomanometer and with the OMRON HEM-907 blood pressure monitor was good (weighted kappa index = 0.68; CI 95%: [0.55–0.79]) and improved when the ABI cut-off value was set at ≤0.70 (weighted kappa index = 0.92; CI 95%: [0.81–1.00]). Sensitivity and specificity were 77.5% and 98.2%, respectively. PPV was 83.8% and NPV was 97.3%. With the ABI cut-off value ≤0.70, sensitivity and specificity increased to 85.7% and 100%, respectively, PPV to 100% and NPV to 99.4%. Conclusion The combination of a Doppler device with the hybrid sphygmomanometer is a simple and reliable method to measure ABI showing that hybrid sphygmomanometer is a good alternative to the use of mercury sphygmomanometers. PMID:23497339

  17. The Arabidopsis cax3 mutants display altered salt tolerance, pH sensitivity and reduced plasma membrane H+-ATPase activity.

    PubMed

    Zhao, Jian; Barkla, Bronwyn J; Marshall, Joy; Pittman, Jon K; Hirschi, Kendal D

    2008-02-01

    Perturbing CAX1, an Arabidopsis vacuolar H+/Ca2+ antiporter, and the related vacuolar transporter CAX3, has been previously shown to cause severe growth defects; however, the specific function of CAX3 has remained elusive. Here, we describe plant phenotypes that are shared among cax1 and cax3 including an increased sensitivity to both abscisic acid (ABA) and sugar during germination, and an increased tolerance to ethylene during early seedling development. We have also identified phenotypes unique to cax3, namely salt, lithium and low pH sensitivity. We used biochemical measurements to ascribe these cax3 sensitivities to a reduction in vacuolar H+/Ca2+ transport during salt stress and decreased plasma membrane H+-ATPase activity. These findings catalog an array of CAX phenotypes and assign a specific role for CAX3 in response to salt tolerance.

  18. Comparison of credible patients of very low intelligence and non-credible patients on neurocognitive performance validity indicators.

    PubMed

    Smith, Klayton; Boone, Kyle; Victor, Tara; Miora, Deborah; Cottingham, Maria; Ziegler, Elizabeth; Zeller, Michelle; Wright, Matthew

    2014-01-01

    The purpose of this archival study was to identify performance validity tests (PVTs) and standard IQ and neurocognitive test scores, which singly or in combination, differentiate credible patients of low IQ (FSIQ ≤ 75; n = 55) from non-credible patients. We compared the credible participants against a sample of 74 non-credible patients who appeared to have been attempting to feign low intelligence specifically (FSIQ ≤ 75), as well as a larger non-credible sample (n = 383) unselected for IQ. The entire non-credible group scored significantly higher than the credible participants on measures of verbal crystallized intelligence/semantic memory and manipulation of overlearned information, while the credible group performed significantly better on many processing speed and memory tests. Additionally, credible women showed faster finger-tapping speeds than non-credible women. The credible group also scored significantly higher than the non-credible subgroup with low IQ scores on measures of attention, visual perceptual/spatial tasks, processing speed, verbal learning/list learning, and visual memory, and credible women continued to outperform non-credible women on finger tapping. When cut-offs were selected to maintain approximately 90% specificity in the credible group, sensitivity rates were highest for verbal and visual memory measures (i.e., TOMM trials 1 and 2; Warrington Words correct and time; Rey Word Recognition Test total; RAVLT Effort Equation, Trial 5, total across learning trials, short delay, recognition, and RAVLT/RO discriminant function; and Digit Symbol recognition), followed by select attentional PVT scores (i.e., b Test omissions and time to recite four digits forward). When failure rates were tabulated across seven most sensitive scores, a cut-off of ≥ 2 failures was associated with 85.4% specificity and 85.7% sensitivity, while a cut-off of ≥ 3 failures resulted in 95.1% specificity and 66.0% sensitivity. Results are discussed in light of extant literature and directions for future research.

  19. Autonomous identification of freezing of gait in Parkinson's disease from lower-body segmental accelerometry

    PubMed Central

    2013-01-01

    Background We have previously published a technique for objective assessment of freezing of gait (FOG) in Parkinson's disease (PD) from a single shank-mounted accelerometer. Here we extend this approach to evaluate the optimal configuration of sensor placement and signal processing parameters using seven sensors attached to the lumbar back, thighs, shanks and feet. Methods Multi-segmental acceleration data was obtained from 25 PD patients performing 134 timed up and go tasks, and clinical assessment of FOG was performed by two experienced raters from video. Four metrics were used to compare objective and clinical measures; the intraclass correlation coefficient (ICC) for number of FOG episodes and the percent time frozen per trial; and the sensitivity and specificity of FOG detection. Results The seven-sensor configuration was the most robust, scoring highly on all measures of performance (ICC number of FOG 0.75; ICC percent time frozen 0.80; sensitivity 84.3%; specificity 78.4%). A simpler single-shank sensor approach provided similar ICC values and exhibited a high sensitivity to FOG events, but specificity was lower at 66.7%. Recordings from the lumbar sensor offered only moderate agreement with the clinical raters in terms of absolute number and duration of FOG events (likely due to musculoskeletal attenuation of lower-limb 'trembling' during FOG), but demonstrated a high sensitivity (86.2%) and specificity (82.4%) when considered as a binary test for the presence/absence of FOG within a single trial. Conclusions The seven-sensor approach was the most accurate method for quantifying FOG, and is best suited to demanding research applications. A single shank sensor provided measures comparable to the seven-sensor approach but is relatively straightforward in execution, facilitating clinical use. A single lumbar sensor may provide a simple means of objective FOG detection given the ubiquitous nature of accelerometers in mobile telephones and other belt-worn devices. PMID:23405951

  20. Interleukin-2 Receptor and Angiotensin-Converting Enzyme as Markers for Ocular Sarcoidosis

    PubMed Central

    Gundlach, Enken; Hoffmann, Michael Marcus; Prasse, Antje; Heinzelmann, Sonja; Ness, Thomas

    2016-01-01

    Purpose To study the impact of soluble IL2 receptor (sIL2R), chest x-ray (CxR), and angiotensin-converting enzyme (ACE) as markers for sarcoidosis in uveitis patients. Design Retrospective study. Methods Serum concentrations of sIL2R and ACE were measured in patients with active uveitis. Those with elevated sIL2R and /or ACE values were examined for suspected systemic sarcoidosis. Main Outcome Measure Our main outcome parameters were the specificity and sensitivity of sIL2R, CxR and ACE in screening for ocular sarcoidosis. Results We measured 261 patients with uveitis for sarcoidosis using sIL2R and ACE between January 2008 and November 2011; sarcoidosis was been diagnosed using other tests (e.g. computer tomography, brochoalveolar lavage, biopsy) in 41 of 53 patients with elevated sIL2R values (>639 U/ml) and in one patient with normal sIL2R (582 U/ml). Their mean sIL2R value was 1310 U/ml, extending from 582 to 8659 U/ml. Only 9 patients, however, presented elevated ACE (>82 U/l). Their mean ACE value was 116.4 U/l, ranging from 84.1 to 175.5 U/l. IL2R specificity was 94% with 98% sensitivity. In contrast, ACE had a specificity of 99.5%, but a sensitivity of only 22%; the chest x-ray had a specificity of 100% with 50% sensitivity in detecting sarcoidosis. We observed the entire spectrum of uveitis: sixteen patients suffered from anterior, 8 from intermediate, 16 from posterior, and 2 from panuveitis. Conclusions An elevated level of soluble IL2R suggests sarcoidosis with uveitis more convincingly than ACE, making sIL2R a more effective marker parameter for sarcoidosis than ACE or chest x-ray in uveitis patients. PMID:26799486

  1. Diagnostic Sensitivity and Specificity of Dark Adaptometry for Detection of Age-Related Macular Degeneration

    PubMed Central

    Jackson, Gregory R.; Scott, Ingrid U.; Kim, Ivana K.; Quillen, David A.; Iannaccone, Alessandro; Edwards, John G.

    2014-01-01

    Purpose. Difficulty with night vision is a common complaint of patients with age-related macular degeneration (AMD). Consistent with this complaint, dark adaptation (DA) is substantially impaired in these patients. Because of the severity of the deficit, measurement of DA has been suggested as a means for the diagnosis of AMD. Previous methods for measurement of DA were time intensive (>30 minutes), which made them unsuitable for clinical use. This study evaluated a rapid DA test (≤6.5 minutes) for the detection of AMD. Methods. Dark adaptation was measured by using the AdaptDx dark adaptometer in two groups: subjects with normal retinal health and subjects with AMD. Subjects were assigned to their group by clinical examination and grading of fundus photographs. Subjects were classified as having DA consistent with normal retinal health (rod intercept ≤ 6.5 minutes) or having dark adaptation consistent with AMD (rod intercept > 6.5 minutes). Results. The eligible sample for analysis included 21 normal adults and 127 AMD patients. The rapid test was found to have a diagnostic sensitivity of 90.6% (P < 0.001) and specificity of 90.5% (P < 0.027). Thus, abnormal DA was detected in 115 of 127 AMD patients, and normal DA was found in 19 of 21 normal adults. Conclusions. The high diagnostic sensitivity and specificity compared favorably to long-duration research methods for the measurement of DA, and slit lamp biomicroscopy performed by a retina specialist. These results suggest that a rapid DA test is useful for the detection of AMD. PMID:24550363

  2. The validity of activity monitors for measuring sleep in elite athletes.

    PubMed

    Sargent, Charli; Lastella, Michele; Halson, Shona L; Roach, Gregory D

    2016-10-01

    There is a growing interest in monitoring the sleep of elite athletes. Polysomnography is considered the gold standard for measuring sleep, however this technique is impractical if the aim is to collect data simultaneously with multiple athletes over consecutive nights. Activity monitors may be a suitable alternative for monitoring sleep, but these devices have not been validated against polysomnography in a population of elite athletes. Participants (n=16) were endurance-trained cyclists participating in a 6-week training camp. A total of 122 nights of sleep were recorded with polysomnography and activity monitors simultaneously. Agreement, sensitivity, and specificity were calculated from epoch-for-epoch comparisons of polysomnography and activity monitor data. Sleep variables derived from polysomnography and activity monitors were compared using paired t-tests. Activity monitor data were analysed using low, medium, and high sleep-wake thresholds. Epoch-for-epoch comparisons showed good agreement between activity monitors and polysomnography for each sleep-wake threshold (81-90%). Activity monitors were sensitive to sleep (81-92%), but specificity differed depending on the threshold applied (67-82%). Activity monitors underestimated sleep duration (18-90min) and overestimated wake duration (4-77min) depending on the threshold applied. Applying the correct sleep-wake threshold is important when using activity monitors to measure the sleep of elite athletes. For example, the default sleep-wake threshold (>40 activity counts=wake) underestimates sleep duration by ∼50min and overestimates wake duration by ∼40min. In contrast, sleep-wake thresholds that have a high sensitivity to sleep (>80 activity counts=wake) yield the best combination of agreement, sensitivity, and specificity. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  3. Predicting gestational diabetes mellitus during the first trimester using anthropometric measurements and HOMA-IR.

    PubMed

    Alptekin, Hüsnü; Çizmecioğlu, Ahmet; Işık, Hatice; Cengiz, Türkan; Yildiz, Murat; Iyisoy, Mehmet Sinan

    2016-05-01

    To determine the predictability of gestational diabetes mellitus (GDM) during the first trimester using the degree of insulin resistance and anthropometric measurements and to assign the risk of developing GDM by weight gained during pregnancy (WGDP). A total of 250 singleton pregnancies at 7-12 gestational weeks were studied. Body mass index (BMI), waist/hip ratio (WHR), quantitative insulin sensitivity check index (QUICKI), homeostasis model assessment-insulin resistance (HOMA-IR) scores and WGDP were determined. The backward stepwise method was applied to estimate possible associations with GDM. Cutoff points were estimated using receiver operating characteristic curve analysis. GDM was found in 20 of 227 singleton pregnancies (8.8 %). The calculated HOMA-IR, QUICKI, BMI, WHR, WGDP, and parity were significantly associated with GDM. Logistic regression analyses showed that three covariates (HOMA-IR, BMI, WGDP) remained independently associated with GDM. It was calculated as OR 1.254 (95 % CI 1.006-1.563), AUC 0.809, sensitivity 90 %, specificity 61 % with cutoff = 2.08 for HOMA-IR; OR 1.157 (CI 1.045-1.281), AUC 0.723, sensitivity 80 %, specificity 58 % with cutoff = 25.95 for BMI; OR 1.221, (CI 1.085-1.374), AUC 0.654, sensitivity 80 %, specificity 46 % with cutoff = 4.7 for WGDP. Despite a HOMA-IR score of >3.1 in pregnant women, GDM was detected in only three of 29 patients (10.3 %) if WGDP was <4.7 kg at weeks 24-28. First trimester screening for GDM can be achieved based on maternal anthropometric measurements and HOMA-IR. In particular, if BMI is >25.95 kg/m(2) and the HOMA-IR score >2.08, controlling weight gain may protect against GDM.

  4. Correlation of Diffusion and Metabolic Alterations in Different Clinical Forms of Multiple Sclerosis

    PubMed Central

    Hannoun, Salem; Bagory, Matthieu; Durand-Dubief, Francoise; Ibarrola, Danielle; Comte, Jean-Christophe; Confavreux, Christian; Cotton, Francois; Sappey-Marinier, Dominique

    2012-01-01

    Diffusion tensor imaging (DTI) and MR spectroscopic imaging (MRSI) provide greater sensitivity than conventional MRI to detect diffuse alterations in normal appearing white matter (NAWM) of Multiple Sclerosis (MS) patients with different clinical forms. Therefore, the goal of this study is to combine DTI and MRSI measurements to analyze the relation between diffusion and metabolic markers, T2-weighted lesion load (T2-LL) and the patients clinical status. The sensitivity and specificity of both methods were then compared in terms of MS clinical forms differentiation. MR examination was performed on 71 MS patients (27 relapsing remitting (RR), 26 secondary progressive (SP) and 18 primary progressive (PP)) and 24 control subjects. DTI and MRSI measurements were obtained from two identical regions of interest selected in left and right centrum semioval (CSO) WM. DTI metrics and metabolic contents were significantly altered in MS patients with the exception of N-acetyl-aspartate (NAA) and NAA/Choline (Cho) ratio in RR patients. Significant correlations were observed between diffusion and metabolic measures to various degrees in every MS patients group. Most DTI metrics were significantly correlated with the T2-LL while only NAA/Cr ratio was correlated in RR patients. A comparison analysis of MR methods efficiency demonstrated a better sensitivity/specificity of DTI over MRSI. Nevertheless, NAA/Cr ratio could distinguish all MS and SP patients groups from controls, while NAA/Cho ratio differentiated PP patients from controls. This study demonstrated that diffusivity changes related to microstructural alterations were correlated with metabolic changes and provided a better sensitivity to detect early changes, particularly in RR patients who are more subject to inflammatory processes. In contrast, the better specificity of metabolic ratios to detect axonal damage and demyelination may provide a better index for identification of PP patients. PMID:22479330

  5. Detection of low-level environmental chemical allergy by a long-term sensitization method.

    PubMed

    Fukuyama, Tomoki; Ueda, Hideo; Hayashi, Koichi; Tajima, Yukari; Shuto, Yasufumi; Saito, Toru R; Harada, Takanori; Kosaka, Tadashi

    2008-07-30

    Multiple chemical sensitivity (MCS) is characterized by various signs, including neurological disorders and allergy. Exposure may occur through a major event, such as a chemical spill, or from long-term contact with chemicals at low levels. We are interested in the allergenicity of MCS and the detection of low-level chemical-related hypersensitivity. We used long-term sensitization followed by low-dose challenge to evaluate sensitization by well-known Th2 type sensitizers (trimellitic anhydride (TMA) and toluene diisocyanate (TDI)) and a Th1 type sensitizer (2,4-dinitrochlorobenzene (DNCB)). After topically sensitizing BALB/c mice (9 times in 3 weeks) and challenging them with TMA, TDI or DNCB, we assayed their auricular lymph nodes (LNs) for number of lymphocytes, surface antigen expression of B cells, and local cytokine production, and measured antigen-specific serum IgE levels. TMA and TDI induced marked increases in levels of antigen-specific serum IgE and of Th2 cytokines (IL-4, IL-5, IL-10, and IL-13) produced by ex vivo restimulated lymph node cells. DNCB induced a marked increase in Th1 cytokine (IL-2, IFN-gamma, and TNF-alpha) levels, but antigen-specific serum IgE levels were not elevated. All chemicals induced significant increases in number of lymphocytes and surface antigen expression of B cells. Our mouse model enabled the identification and characterization of chemical-related allergic reactions at low levels. This long-term sensitization method would be useful for detecting environmental chemical-related hypersensitivity.

  6. Improving guideline sensitivity and specificity for the identification of proactive gastrostomy placement in patients with head and neck cancer.

    PubMed

    Brown, Teresa E; Crombie, Jane; Spurgin, Ann-Louise; Tripcony, Lee; Keller, Jacqui; Hughes, Brett G M; Dickie, Graeme; Kenny, Lizbeth Moira; Hodge, Robert A

    2016-04-01

    Swallowing and nutrition guidelines for patients with head and neck cancer are available for identification of proactive gastrostomy placement in patients with high nutritional risk. The purpose of this study was to investigate improvements to the validity of these guidelines. A multivariate analysis was fitted to the original dataset (n = 501) to examine the variables that may predict gastrostomy placement (eg, tumor site, treatment, sex, and age). Using these factors, the high risk category was modified and retrospectively validated in the same cohort to provide new measures of sensitivity and specificity. The following were positive predictors of gastrostomy placement: T3 (p = .01), T4 (p < .001), and chemoradiotherapy (p < .001). Laryngeal (p = .02) and skin cancer (p < .001) were negative predictors. Modification of the high risk definition improved sensitivity to 58% and maintained specificity at 92%. Minor modifications to the high risk definition in the guidelines have improved the guideline sensitivity for future use. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1163-E1171, 2016. © 2015 Wiley Periodicals, Inc.

  7. Quantum Error Correction for Metrology

    NASA Astrophysics Data System (ADS)

    Sushkov, Alex; Kessler, Eric; Lovchinsky, Igor; Lukin, Mikhail

    2014-05-01

    The question of the best achievable sensitivity in a quantum measurement is of great experimental relevance, and has seen a lot of attention in recent years. Recent studies [e.g., Nat. Phys. 7, 406 (2011), Nat. Comms. 3, 1063 (2012)] suggest that in most generic scenarios any potential quantum gain (e.g. through the use of entangled states) vanishes in the presence of environmental noise. To overcome these limitations, we propose and analyze a new approach to improve quantum metrology based on quantum error correction (QEC). We identify the conditions under which QEC allows one to improve the signal-to-noise ratio in quantum-limited measurements, and we demonstrate that it enables, in certain situations, Heisenberg-limited sensitivity. We discuss specific applications to nanoscale sensing using nitrogen-vacancy centers in diamond in which QEC can significantly improve the measurement sensitivity and bandwidth under realistic experimental conditions.

  8. The usefulness of "corrected" body mass index vs. self-reported body mass index: comparing the population distributions, sensitivity, specificity, and predictive utility of three correction equations using Canadian population-based data.

    PubMed

    Dutton, Daniel J; McLaren, Lindsay

    2014-05-06

    National data on body mass index (BMI), computed from self-reported height and weight, is readily available for many populations including the Canadian population. Because self-reported weight is found to be systematically under-reported, it has been proposed that the bias in self-reported BMI can be corrected using equations derived from data sets which include both self-reported and measured height and weight. Such correction equations have been developed and adopted. We aim to evaluate the usefulness (i.e., distributional similarity; sensitivity and specificity; and predictive utility vis-à-vis disease outcomes) of existing and new correction equations in population-based research. The Canadian Community Health Surveys from 2005 and 2008 include both measured and self-reported values of height and weight, which allows for construction and evaluation of correction equations. We focused on adults age 18-65, and compared three correction equations (two correcting weight only, and one correcting BMI) against self-reported and measured BMI. We first compared population distributions of BMI. Second, we compared the sensitivity and specificity of self-reported BMI and corrected BMI against measured BMI. Third, we compared the self-reported and corrected BMI in terms of association with health outcomes using logistic regression. All corrections outperformed self-report when estimating the full BMI distribution; the weight-only correction outperformed the BMI-only correction for females in the 23-28 kg/m2 BMI range. In terms of sensitivity/specificity, when estimating obesity prevalence, corrected values of BMI (from any equation) were superior to self-report. In terms of modelling BMI-disease outcome associations, findings were mixed, with no correction proving consistently superior to self-report. If researchers are interested in modelling the full population distribution of BMI, or estimating the prevalence of obesity in a population, then a correction of any kind included in this study is recommended. If the researcher is interested in using BMI as a predictor variable for modelling disease, then both self-reported and corrected BMI result in biased estimates of association.

  9. Application of support vector machine method for the analysis of absorption spectra of exhaled air of patients with broncho-pulmonary diseases

    NASA Astrophysics Data System (ADS)

    Bukreeva, Ekaterina B.; Bulanova, Anna A.; Kistenev, Yury V.; Kuzmin, Dmitry A.; Tuzikov, Sergei A.; Yumov, Evgeny L.

    2014-11-01

    The results of the joint use of laser photoacoustic spectroscopy and chemometrics methods in gas analysis of exhaled air of patients with respiratory diseases (chronic obstructive pulmonary disease, pneumonia and lung cancer) are presented. The absorption spectra of exhaled breath of all volunteers were measured, the classification methods of the scans of the absorption spectra were applied, the sensitivity/specificity of the classification results were determined. It were obtained a result of nosological in pairs classification for all investigated volunteers, indices of sensitivity and specificity.

  10. Measures of accuracy and performance of diagnostic tests.

    PubMed

    Drobatz, Kenneth J

    2009-05-01

    Diagnostic tests are integral to the practice of veterinary cardiology, any other specialty, and general veterinary medicine. Developing and understanding diagnostic tests is one of the cornerstones of clinical research. This manuscript describes the diagnostic test properties including sensitivity, specificity, predictive value, likelihood ratio, receiver operating characteristic curve. Review of practical book chapters and standard statistics manuscripts. Diagnostics such as sensitivity, specificity, predictive value, likelihood ratio, and receiver operating characteristic curve are described and illustrated. Basic understanding of how diagnostic tests are developed and interpreted is essential in reviewing clinical scientific papers and understanding evidence based medicine.

  11. Optimized enzyme-linked immunosorbent assay for detecting cytomegalovirus infections during clinical trials of recombinant vaccines.

    PubMed

    Pagnon, Anke; Piras, Fabienne; Gimenez-Fourage, Sophie; Dubayle, Joseline; Arnaud-Barbe, Nadège; Hessler, Catherine; Caillet, Catherine

    2017-11-01

    In clinical trials of cytomegalovirus (CMV) glycoprotein B (gB) vaccines, CMV infection is detected by first depleting serum of anti-gB antibodies and then measuring anti-CMV antibodies with a commercially available enzyme-linked immunosorbent assay (ELISA) kit, with confirmation of positive findings by immunoblot. Identification of CMV immunoantigens for the development of an ELISA that detects specifically CMV infection in clinical samples from individuals immunized with gB vaccines. Sensitivity and specificity of ELISAs using antigenic regions of CMV proteins UL83/pp65, UL99/pp28, UL44/pp52, UL80a/pp38, UL57, and UL32/pp150 were measured. An IgG ELISA using a UL32/pp150 [862-1048] capture peptide was the most specific (93.7%) and sensitive (96.4%) for detecting CMV-specific antibodies in sera. The ELISA successfully detected CMV-specific antibodies in 22 of 22 sera of subjects who had been vaccinated with a gB vaccine but who had later been infected with CMV. The ELISA was linear over a wide range of CMV concentrations (57-16,814 ELISA units/mL) and was reproducible as indicated by a 5% intra-day and 7% inter-day coefficients of variation. The signal was specifically competed by UL32/pp150 [862-1048] peptide but not by CMV-gB or herpes simplex virus 2 glycoprotein D. Lipid and hemoglobin matrix did not interfere with the assay. The UL32/pp150 [862-1048] IgG ELISA can be used for the sensitive and specific detection of CMV infection in gB-vaccinated individuals. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Improving the depth sensitivity of time-resolved measurements by extracting the distribution of times-of-flight

    PubMed Central

    Diop, Mamadou; St. Lawrence, Keith

    2013-01-01

    Time-resolved (TR) techniques provide a means of discriminating photons based on their time-of-flight. Since early arriving photons have a lower probability of probing deeper tissue than photons with long time-of-flight, time-windowing has been suggested as a method for improving depth sensitivity. However, TR measurements also contain instrument contributions (instrument-response-function, IRF), which cause temporal broadening of the measured temporal point-spread function (TPSF) compared to the true distribution of times-of-flight (DTOF). The purpose of this study was to investigate the influence of the IRF on the depth sensitivity of TR measurements. TPSFs were acquired on homogeneous and two-layer tissue-mimicking phantoms with varying optical properties. The measured IRF and TPSFs were deconvolved using a stable algorithm to recover the DTOFs. The microscopic Beer-Lambert law was applied to the TPSFs and DTOFs to obtain depth-resolved absorption changes. In contrast to the DTOF, the latest part of the TPSF was not the most sensitive to absorption changes in the lower layer, which was confirmed by computer simulations. The improved depth sensitivity of the DTOF was illustrated in a pig model of the adult human head. Specifically, it was shown that dynamic absorption changes obtained from the late part of the DTOFs recovered from TPSFs acquired by probes positioned on the scalp were similar to absorption changes measured directly on the brain. These results collectively demonstrate that this method improves the depth sensitivity of TR measurements by removing the effects of the IRF. PMID:23504445

  13. Reliable change of the sensory organization test.

    PubMed

    Broglio, Steven P; Ferrara, Michael S; Sopiarz, Kay; Kelly, Michael S

    2008-03-01

    To establish the sensitivity and specificity of the NeuroCom Sensory Organization Test (SOT) and provide practitioners with cut-scores for clinical decision making using estimates of reliable change. Retrospective cohort study. Research laboratory. Healthy (n = 66) and concussed (n = 63) young adult participants. Postural control assessments on the NeuroCom SOT were completed twice (baseline and follow-up) for both groups. Postconcussion assessments were administered within 24 hours of injury diagnosis. The reliable change technique was used to calculated cut-scores for each SOT variable (composite balance; somatosensory, visual, and vestibular ratios) at the 95%, 90%, 85%, 80%, 75%, and 70% confidence interval levels. When cut-scores were applied to the post-concussion evaluations, sensitivity and specificity varied with SOT variable and confidence interval. An evaluation for change on one or more SOT variable resulted in the highest combined sensitivity (57%) and specificity (80%) at the 75% confidence interval. Use of reliable change scores to detect significant changes in performance on the SOT resulted in decreased sensitivity and improved specificity compared to a previous report. These findings indicate that some concussed athletes may not show large changes in postconcussion postural control and this postural control evaluation should not be used in exclusion of other assessment techniques. The postural control assessment should be combined with other evaluative measures to gain the highest sensitivity to concussive injuries.

  14. Sensitivity and specificity of digital retinal imaging for screening diabetic retinopathy.

    PubMed

    Lopez-Bastida, J; Cabrera-Lopez, F; Serrano-Aguilar, P

    2007-04-01

    To assess the effectiveness of a non-mydriatic digital camera (45 degrees -30 degrees photographs) compared with the reference method for screening diabetic retinopathy. Type 1 and 2 diabetic patients (n = 773; 1546 eyes) underwent screening for diabetic retinopathy in a prospective observational study. Hospital-based non-mydriatic digital retinal imaging by a consultant specialist in retinal diseases was compared with slit-lamp biomicroscopy and indirect ophthalmoscopy through dilated pupils, as a gold standard, previously performed in a community health centre by another consultant specialist in retinal diseases. The main outcome measures were sensitivity and specificity of screening methods and prevalence of diabetic retinopathy. The prevalence of any form of diabetic retinopathy was 42.4% (n = 328); the prevalence of sight-threatening including macular oedema and proliferative retinopathy was 9.6% (n = 74). Sensitivity of detection of any diabetic retinopathy by digital imaging was 92% (95% confidence interval 90, 94). Specificity of detection of any diabetic retinopathy was 96% (95, 98). The predictive value of the negative tests was 94% and of a positive test 95%. For sight-threatening retinopathy digital imaging had a sensitivity of 100%. A high sensitivity and specificity are essential for an effective screening programme. These results confirm digital retinal imaging with a non-mydriatic camera as an effective option in community-based screening programmes for diabetic retinopathy.

  15. Nonmonetary Decision-Making Indices Discriminate Between Different Behavioral Components of Gambling.

    PubMed

    Navas, Juan F; Torres, Ana; Vilar, Raquel; Verdejo-García, Antonio; Catena, Andrés; Perales, José C

    2015-12-01

    Recent research has proposed that altered reward and punishment sensitivity, heightened impulsivity, and faulty dynamic decision-making are at the core of disordered gambling. However, each of these traits and cognitive aspects dimensionally vary in the normal population, such that the link between individual differences in these dimensions and gambling use can be ultimately informative to explain disordered gambling. The main aim of the present study was to investigate the contribution of such decision-making-related indices to gambling use parameters in a community sample of college students. Assessment included punishment and reward sensitivity (as measured by the shortened Sensitivity to Punishment and Sensitivity to Reward Questionnaire), impulsivity (as measured by the UPPS-P model and a motor inhibition Go/No-go task), and dynamic decision-making [as measured by the probabilistic reversal learning task (PRLT)]. A structured interview was conducted to explore quantitative aspects of the participants gambling habits (gambling presence, gambling frequency, and average amount of money spent in gambling per unit of time). Our results showed the existence of a decision-making profile of gambling, as it naturally occurs in college students, in which sensation seeking is directly and specifically related to gambling presence (gambling, or not gambling at all), punishment sensitivity is inversely related to gambling frequency, and inflexibility in the PRLT specifically predicts the losses accrued because of gambling. These results are compatible with the idea that sensation seeking and punishment insensitivity could increase exposure to gambling activities, whereas reversal learning inflexibility, in people who already gamble, could boost the risk to accumulate losses.

  16. Immunity to Salmonella typhi: considerations relevant to measurement of cellular immunity in typhoid-endemic regions.

    PubMed Central

    Murphy, J R; Wasserman, S S; Baqar, S; Schlesinger, L; Ferreccio, C; Lindberg, A A; Levine, M M

    1989-01-01

    Experiments were performed in Baltimore, Maryland and in Santiago, Chile, to determine the level of Salmonella typhi antigen-driven in vitro lymphocyte replication response which signifies specific acquired immunity to this bacterium and to determine the best method of data analysis and form of data presentation. Lymphocyte replication was measured as incorporation of 3H-thymidine into desoxyribonucleic acid. Data (ct/min/culture) were analyzed in raw form and following log transformation, by non-parametric and parametric statistical procedures. A preference was developed for log-transformed data and discriminant analysis. Discriminant analysis of log-transformed data revealed 3H-thymidine incorporation rates greater than 3,433 for particulate S. typhi, Ty2 antigen stimulated cultures signified acquired immunity at a sensitivity and specificity of 82.7; for soluble S. typhi O polysaccharide antigen-stimulated cultures, ct/min/culture values of greater than 1,237 signified immunity (sensitivity and specificity 70.5%). PMID:2702777

  17. Examining unusual digit span performance in a population of postsecondary students assessed for academic difficulties.

    PubMed

    Harrison, Allyson G; Rosenblum, Yoni; Currie, Shannon

    2010-09-01

    Methods of identifying poor test-related motivation using the Wechsler Adult Intelligence Scale Digit Span subtest are based on identification of performance patterns that are implausible if the test taker is investing full effort. No studies to date, however, have examined the specificity of such measures, particularly when evaluating persons with either known or suspected learning or attention disorders. This study investigated performance of academically challenged students on three measures embedded in the Wechsler Adult Intelligence Scale-III, namely, low Digit Span, high Vocabulary-Digit span (Voc-DS), and low Reliable Digit Span scores. Evaluating subjects believed to be investing full effort in testing, it was found that both Digit Span and Reliable Digit Span had high specificity, although both showed relatively lower sensitivity. In contrast, VOC-DS was especially weak in both sensitivity and specificity, with an apparent false positive rate of 28%. Use of VOC-DS is therefore not appropriate for those with a history of learning or attention problems.

  18. Childhood executive function inventory (CHEXI): a promising measure for identifying young children with ADHD?

    PubMed

    Thorell, Lisa B; Eninger, Lilianne; Brocki, Karin C; Bohlin, Gunilla

    2010-01-01

    The present study investigated whether the Childhood Executive Function Inventory (CHEXI) can discriminate between young children fulfilling the diagnostic criteria for attention-deficit/hyperactivity disorder (ADHD) and normally developing children. Unlike other executive function rating instruments, the CHEXI focuses specifically on inhibitory control and working memory, without including items that overlap with the diagnostic criteria of ADHD. The CHEXI was found to discriminate very well between children fulfilling the criteria for ADHD and normally developing children, also when controlling for the effect of IQ and socioeconomic status (SES). Both sensitivity and specificity of the two CHEXI subscales were shown to be high using either parent or teacher ratings. The highest overall classification rate was found for parent ratings on the inhibition subscale, with sensitivity and specificity reaching 93.3. To summarize, the CHEXI should be considered a promising measure for identifying young children with ADHD, although it is for future research to determine whether the CHEXI can be successfully used to also discriminate between different psychopathological groups.

  19. The accuracy of parent-reported height and weight for 6-12 year old U.S. children.

    PubMed

    Wright, Davene R; Glanz, Karen; Colburn, Trina; Robson, Shannon M; Saelens, Brian E

    2018-02-12

    Previous studies have examined correlations between BMI calculated using parent-reported and directly-measured child height and weight. The objective of this study was to validate correction factors for parent-reported child measurements. Concordance between parent-reported and investigator measured child height, weight, and BMI (kg/m 2 ) among participants in the Neighborhood Impact on Kids Study (n = 616) was examined using the Lin coefficient, where a value of ±1.0 indicates perfect concordance and a value of zero denotes non-concordance. A correction model for parent-reported height, weight, and BMI based on commonly collected demographic information was developed using 75% of the sample. This model was used to estimate corrected measures for the remaining 25% of the sample and measured concordance between correct parent-reported and investigator-measured values. Accuracy of corrected values in classifying children as overweight/obese was assessed by sensitivity and specificity. Concordance between parent-reported and measured height, weight and BMI was low (0.007, - 0.039, and - 0.005 respectively). Concordance in the corrected test samples improved to 0.752 for height, 0.616 for weight, and 0.227 for BMI. Sensitivity of corrected parent-reported measures for predicting overweight and obesity among children in the test sample decreased from 42.8 to 25.6% while specificity improved from 79.5 to 88.6%. Correction factors improved concordance for height and weight but did not improve the sensitivity of parent-reported measures for measuring child overweight and obesity. Future research should be conducted using larger and more nationally-representative samples that allow researchers to fully explore demographic variance in correction coefficients.

  20. Quantitative measurement of human thyroglobulin-specific antibodies by use of a sensitive enzyme-linked immunoassay.

    PubMed

    Kuppers, R C; Outschoorn, I M; Hamilton, R G; Burek, C L; Rose, N R

    1993-04-01

    A quantitative enzyme-linked immunoassay that measures in absolute terms the subclass concentration of human thyroglobulin (huTg)-specific IgG autoantibody was developed. Unique to this study was the use of an affinity-purified anti-huTg standard with a known concentration of the four IgG subclasses. The sensitivity of the ELISA assay was 1-5 ng/ml depending on the IgG subclass being measured. We examined 22 sera of patients with autoimmune thyroid disease. The total huTg-specific antibody concentrations in serum ranged from 0 to nearly 3000 micrograms/ml of IgG. The IgG subclass distribution in individuals with low huTg-specific IgG (< 10 micrograms/ml) was primarily IgG1 and IgG3 Ab. Patients with intermediate levels of huTg IgG (10-600 micrograms/ml) expressed all four subclasses; however, no particular subclass was dominant. Individuals with > 1000 micrograms/ml also showed huTg-Ab in all four subclasses, however, IgG1 and IgG2 were dominant. All four IgG subclasses were used in the response to huTg, although the pattern of usage varied between individuals. There was no dominant subclass usage seen in this patient population.

  1. Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography.

    PubMed

    Paul, Shashi B; Das, Prasenjit; Mahanta, Mousumi; Sreenivas, Vishnubhatla; Kedia, Saurabh; Kalra, Nancy; Kaur, Harpreet; Vijayvargiya, Maneesh; Ghosh, Shouriyo; Gamanagatti, Shivanand R; Shalimar; Gupta, Siddhartha Dutta; Acharya, Subrat K

    2017-12-01

    To evaluate the diagnostic accuracy of shear wave elastography (SWE) and transient elastography (TE) in the evaluation of liver fibrosis in chronic hepatitis B (CHB) and C (CHC) patients taking liver biopsy as gold standard. Ethics committee approved this prospective cross-sectional study. Between October 2012 and December 2014, consecutive CHB/CHC patients fulfilling the inclusion criteria were included-age more than 18 years, informed written consent, willing and suitable for liver biopsy. SWE, TE, and biopsy were performed the same day. Liver stiffness measurement (LSM) cut-offs for various stages of fibrosis were generated for SWE and TE. AUC, sensitivity, specificity, and positive/negative predictive values were estimated individually or in combination. CH patients (n = 240, CHB 172, CHC 68), 176 males, 64 females, mean age 32.6 ± 11.6 years were enrolled. Mean LSM of patients with no histological fibrosis (F0) was 5.0 ± 0.7 and 5.1+1.4 kPa on SWE and TE, respectively. For differentiating F2 and F3-4 fibrosis on SWE, at 7.0 kPa cut-off, the sensitivity was 81.3% and specificity 77.6%. For TE, at 8.3 kPa cut-off, sensitivity was 81.8% and specificity 83.1%. For F3 vs. F4, SWE sensitivity was 83.3% and specificity 90.7%. At 14.8 kPa cut-off, TE showed similar sensitivity (83.3%) but specificity increased to 96.5%. Significant correlation between SWE and TE was observed (r = 0.33, p < 0.001). On combining SWE and TE, a drop in sensitivity with increased specificity for all stages of liver fibrosis occured. SWE is an accurate technique for evaluating liver fibrosis. SWE compares favorably with TE especially for predicting advanced fibrosis/cirrhosis. Combining SWE and TE further improves specificity.

  2. Lowering the quantification limit of the QubitTM RNA HS assay using RNA spike-in.

    PubMed

    Li, Xin; Ben-Dov, Iddo Z; Mauro, Maurizio; Williams, Zev

    2015-05-06

    RNA quantification is often a prerequisite for most RNA analyses such as RNA sequencing. However, the relatively low sensitivity and large sample consumption of traditional RNA quantification methods such as UV spectrophotometry and even the much more sensitive fluorescence-based RNA quantification assays, such as the Qubit™ RNA HS Assay, are often inadequate for measuring minute levels of RNA isolated from limited cell and tissue samples and biofluids. Thus, there is a pressing need for a more sensitive method to reliably and robustly detect trace levels of RNA without interference from DNA. To improve the quantification limit of the Qubit™ RNA HS Assay, we spiked-in a known quantity of RNA to achieve the minimum reading required by the assay. Samples containing trace amounts of RNA were then added to the spike-in and measured as a reading increase over RNA spike-in baseline. We determined the accuracy and precision of reading increases between 1 and 20 pg/μL as well as RNA-specificity in this range, and compared to those of RiboGreen(®), another sensitive fluorescence-based RNA quantification assay. We then applied Qubit™ Assay with RNA spike-in to quantify plasma RNA samples. RNA spike-in improved the quantification limit of the Qubit™ RNA HS Assay 5-fold, from 25 pg/μL down to 5 pg/μL while maintaining high specificity to RNA. This enabled quantification of RNA with original concentration as low as 55.6 pg/μL compared to 250 pg/μL for the standard assay and decreased sample consumption from 5 to 1 ng. Plasma RNA samples that were not measurable by the Qubit™ RNA HS Assay were measurable by our modified method. The Qubit™ RNA HS Assay with RNA spike-in is able to quantify RNA with high specificity at 5-fold lower concentration and uses 5-fold less sample quantity than the standard Qubit™ Assay.

  3. Analysis of different anthropometric indicators in the detection of high blood pressure in school adolescents: a cross-sectional study with 8295 adolescents.

    PubMed

    Christofaro, Diego G D; Farah, Breno Q; Vanderlei, Luiz Carlos M; Delfino, Leandro D; Tebar, William R; Barros, Mauro Virgílio G de; Ritti-Dias, Raphael M

    High blood pressure is strongly associated with obesity in different populations. However, it is unclear whether different anthropometric indicators of obesity can satisfactorily predict high blood pressure in the school setting. This study evaluated the sensitivity and specificity of body mass index, waist circumference, and waist to height ratio in the detection of high blood pressure in adolescents. The sample consisted of 8295 adolescents aged 10-17 years. Weight was measured using a digital scale, height with a stadiometer, and waist circumference using a tape measure. Blood pressure was measured by an automatic blood pressure measuring device. ROC curves were used for the analysis of sensitivity and specificity of the three anthropometric indices in identifying high blood pressure. Binary Logistic Regression was used to assess the association of body mass index, waist circumference, and waist to height ratio with high blood pressure. Low values of sensitivity were observed for body mass index (0.35), waist circumference (0.37), and waist to height ratio (0.31) and high values of specificity for body mass index (0.86), waist circumference (0.82), and waist to height ratio (0.83) in the detection of high blood pressure. An association was observed between adolescents classified with high body mass index (OR=3.57 [95% CI=3.10-4.10]), waist cirumference (OR=3.24 [95% CI=2.83-3.72]), and waist to height ratio (OR=2.94 [95% CI=2.54-3.40]) with high blood pressure. Body mass index, waist circumference, and waist to height ratio presented low sensitivity to identify adolescents with high blood pressure. However, adolescents classified with high body mass index, waist circumference, and waist to height ratio demonstrated a high association of presenting high blood pressure. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. Sensitivity, specificity, and reproducibility of four measures of laboratory turnaround time.

    PubMed

    Valenstein, P N; Emancipator, K

    1989-04-01

    The authors studied the performance of four measures of laboratory turnaround time: the mean, median, 90th percentile, and proportion of tests reported within a predetermined cut-off interval (proportion of acceptable tests [PAT]). Measures were examined with the use of turnaround time data from 11,070 stat partial thromboplastin times, 16,761 urine cultures, and 28,055 stat electrolyte panels performed by a single laboratory. For laboratories with long turnaround times, the most important quality of a turnaround time measure is high reproducibility, so that improvement in reporting speed can be distinguished from random variation resulting from sampling. The mean was found to be the most reproducible of the four measures, followed by the median. The mean achieved acceptable precision with sample sizes of 100-500 tests. For laboratories with normally rapid turnaround times, the most important quality of a measure is high sensitivity and specificity for detecting whether turnaround time has dropped below standards. The PAT was found to be the best measure of turnaround time in this setting but required sample sizes of at least 500 tests to achieve acceptable accuracy. Laboratory turnaround time may be measured for different reasons. The method of measurement should be chosen with an eye toward its intended application.

  5. Optical Fibers Would Sense Local Strains

    NASA Technical Reports Server (NTRS)

    Egalon, Claudio O.; Rogowski, Robert S.

    1994-01-01

    Proposed fiber-optic transducers measure local strains. Includes lead-in and lead-out lengths producing no changes in phase shifts, plus short sensing length in which phase shift is sensitive to strain. Phase shifts in single-mode fibers vary with strains. In alternative version, multiple portions of optical fiber sensitive to strains characteristic of specific vibrational mode of object. Same principle also used with two-mode fiber.

  6. Diagnostic accuracy of shear wave elastography for prediction of breast malignancy in patients with pathological nipple discharge

    PubMed Central

    Guo, Xiaobo; Liu, Ying; Li, Wanhu

    2016-01-01

    Objectives Pathological nipple discharge (PND) may indicate malignant breast lesions. As the role of shear wave elastography (SWE) in predicting these malignant lesions has not yet been evaluated, we aim to evaluate the diagnostic value of SWE for this condition. Design Prospective diagnostic accuracy study comparing a combination of qualitative and quantitative measurements of SWE (index test) to a ductoscopy and microdochectomy for histological diagnosis (reference test). Setting Fuzhou General Hospital of Nanjing military command. Participants A total of 379 patients with PND were finally included from January, 2011 to March 2014, after we screened 1084 possible candidates. All participants were evaluated through SWE, with qualitative parameters generated by Virtual Touch tissue imaging (VTI) and quantitative parameters generated by Virtual Touch tissue quantification (VTQ). All the patients were consented to receive a ductoscopy and microdochectomy for histological diagnosis, and the results were set as a reference test. Outcome measures Sensitivity and specificity of the combined VTI and VTQ of the SWE for detection of malignancy in patients with PND. Results The 379 participants presented with 404 lesions. The results of pathological examination showed that 326 (80.7%) of the 404 lesions were benign and the other 78 (19.3%) were malignant. An area under the curve of elasticity score, VTQm and VTQc, were 0.872, 0.825 and 0.857, respectively, with the corresponding cut-off point as 2.50, 2.860 m/s and 3.015 m/s, respectively. After a combination of these measurements, the sensitivity, specificity, and positive and negative predictive value (PPV and NPV), were 89.7%, 72.1%, 43.5% and 96.7%, respectively. The sensitivity analysis showed 82% of the sensitivity and 96.8% of the specificity, in which patients with no pathological findings in ductoscopy were excluded. Conclusions Ultrasonographic elastography is sensitive for patients with PND and could be used as a triage test before ductoscopy examination. Studies for further improvement of diagnostic sensitivity are warranted. PMID:26801462

  7. Evaluation of acute knee pain in primary care.

    PubMed

    Jackson, Jeffrey L; O'Malley, Patrick G; Kroenke, Kurt

    2003-10-07

    The evaluation of acute knee pain often includes radiography of the knee. To synthesize the literature to determine the role of radiologic procedures in evaluating common causes of acute knee pain: fractures, meniscal or ligamentous injuries, osteoarthritis, and pseudogout. MEDLINE search from 1966 to October 2002. We included all published, peer-reviewed studies of decision rules for fractures. We included studies that used arthroscopy as the gold standard for measuring the accuracy of the physical examination and magnetic resonance imaging (MRI) for meniscal and ligamentous knee damage. We included all studies on the use of radiographs in pseudogout. We extracted all data in duplicate and abstracted physical examination and MRI results into 2 x 2 tables. Among the 5 decision rules for deciding when to use plain films in knee fractures, the Ottawa knee rules (injury due to trauma and age >55 years, tenderness at the head of the fibula or the patella, inability to bear weight for 4 steps, or inability to flex the knee to 90 degrees) have the strongest supporting evidence. When the history suggests a potential meniscal or ligamentous injury, the physical examination is moderately sensitive (meniscus, 87%; anterior cruciate ligament, 74%; and posterior cruciate ligament, 81%) and specific (meniscus, 92%; anterior cruciate ligament, 95%; and posterior cruciate ligament, 95%). The Lachman test is more sensitive and specific for ligamentous tears than is the drawer sign. For meniscal tears, joint line tenderness is sensitive (75%) but not specific (27%), while the McMurray test is specific (97%) but not sensitive (52%). Compared with the physical examination, MRI is more sensitive for ligamentous and meniscal damage but less specific. When the differential diagnosis for acute knee pain includes an exacerbation of osteoarthritis, clinical features (age >50 years, morning stiffness <30 minutes, crepitus, or bony enlargement) are 89% sensitive and 88% specific for underlying chronic arthritis. Adding plain films improves sensitivity slightly but not specificity. Plain films for pseudogout are not sensitive or specific, according to limited-quality studies. We recommend the Ottawa knee rules to decide when to obtain plain films for suspected knee fracture. A careful physical examination should be sufficient to decide whether to refer patients with potential meniscal and ligament injuries, and we prefer clinical criteria rather than plain films for evaluating osteoarthritis. We do not recommend using plain films to diagnose pseudogout.

  8. Can time-averaged flow boundary conditions be used to meet the clinical timeline for Fontan surgical planning?

    PubMed

    Wei, Zhenglun Alan; Trusty, Phillip M; Tree, Mike; Haggerty, Christopher M; Tang, Elaine; Fogel, Mark; Yoganathan, Ajit P

    2017-01-04

    Cardiovascular simulations have great potential as a clinical tool for planning and evaluating patient-specific treatment strategies for those suffering from congenital heart diseases, specifically Fontan patients. However, several bottlenecks have delayed wider deployment of the simulations for clinical use; the main obstacle is simulation cost. Currently, time-averaged clinical flow measurements are utilized as numerical boundary conditions (BCs) in order to reduce the computational power and time needed to offer surgical planning within a clinical time frame. Nevertheless, pulsatile blood flow is observed in vivo, and its significant impact on numerical simulations has been demonstrated. Therefore, it is imperative to carry out a comprehensive study analyzing the sensitivity of using time-averaged BCs. In this study, sensitivity is evaluated based on the discrepancies between hemodynamic metrics calculated using time-averaged and pulsatile BCs; smaller discrepancies indicate less sensitivity. The current study incorporates a comparison between 3D patient-specific CFD simulations using both the time-averaged and pulsatile BCs for 101 Fontan patients. The sensitivity analysis involves two clinically important hemodynamic metrics: hepatic flow distribution (HFD) and indexed power loss (iPL). Paired demographic group comparisons revealed that HFD sensitivity is significantly different between single and bilateral superior vena cava cohorts but no other demographic discrepancies were observed for HFD or iPL. Multivariate regression analyses show that the best predictors for sensitivity involve flow pulsatilities, time-averaged flow rates, and geometric characteristics of the Fontan connection. These predictors provide patient-specific guidelines to determine the effectiveness of analyzing patient-specific surgical options with time-averaged BCs within a clinical time frame. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. [Criterion and Construct Validity in Nursing Diagnosis "Sedentary Lifestyle" in People over 50 Years Old].

    PubMed

    Guirao-Goris, Silamani J; Ferrer Ferrandis, Esperanza; Montejano Lozoya, Raimunda

    2016-02-18

    The aim of the study is to identify the construct and criterion validity of the nursing diagnosis label Sedentary Lifestyle. A cross-sectional study in a nursing consultation in primary health care was conducted. Participants were all people that was attended for one year over 50 who voluntarily wish to participate (n=85) in the study. Objective weekly physical activity was measured in METs with an Accelerometer, objective measure of performance was measured by gait speed EPESE Battery (both measures that were used as the gold standard), and physical activity questionnaires (RAPA), the COOP-WONCA physical fitness chart. Spearman correlation coefficients, mean comparison tests and analysis of sensitivity and specificity were used as statistical analysis. The diagnosis "Sedentary Lifestyle" showed a positive correlation between its manifestations and physical activity measured in METs (r=0.39) and EPESE gait speed (r=0.35). The diagnosis showed a sensitivity of 85.1% and a specificity of 65.2% and showed ability to discriminate active people from those that are not using METs as a measure of physical activity (t=-4.4). The diagnosis "Sedentary Lifestyle" shows criterion and construct validity.

  10. Specific deficit of colour-colour short-term memory binding in sporadic and familial Alzheimer's disease.

    PubMed

    Parra, Mario A; Sala, Sergio Della; Abrahams, Sharon; Logie, Robert H; Méndez, Luis Guillermo; Lopera, Francisco

    2011-06-01

    Short-term memory binding of visual features which are processed across different dimensions (shape-colour) is impaired in sporadic Alzheimer's disease, familial Alzheimer's disease, and in asymptomatic carriers of familial Alzheimer's disease. This study investigated whether Alzheimer's disease also impacts on within-dimension binding processes. The study specifically explored whether visual short-term memory binding of features of the same type (colour-colour) is sensitive to Alzheimer's disease. We used a neuropsychological battery and a short-term memory binding task to assess patients with sporadic Alzheimer's disease (Experiment 1), familial Alzheimer's disease (Experiment 2) due to the mutation E280A of the Presenilin-1 gene and asymptomatic carriers of the mutation. The binding task assessed change detection within arrays of unicoloured objects (Colour Only) or bicoloured objects the colours of which had to be remembered separately (Unbound Colours) or together (Bound Colours). Performance on the Bound Colours condition (1) explained the largest proportion of variance between patients (sporadic and familial Alzheimer's disease), (2) combined more sensitivity and specificity for the disease than other more traditional neuropsychological tasks, (3) identified asymptomatic carriers of the mutation even when traditional neuropsychological measures and other measures of short-term memory did not and, (4) contrary to shape-colour binding, correlated with measures of hippocampal functions. Colour-colour binding and shape-colour binding both appear to be sensitive to AD even though they seem to rely on different brain mechanisms. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Diagnostic Ability of Automated Pupillography in Glaucoma.

    PubMed

    Rao, Harsha L; Kadambi, Sujatha V; Mehta, Pooja; Dasari, Srilakshmi; Puttaiah, Narendra K; Pradhan, Zia S; Rao, Dhanraj A S; Shetty, Rohit

    2017-05-01

    To evaluate the diagnostic ability of automated pupillography measurements in glaucoma and study the effect of inter-eye asymmetry in glaucomatous damage on the diagnostic ability. In an observational, cross-sectional study, 47 glaucoma patients and 42 control subjects underwent automated pupillography using a commercially available device. Diagnostic abilities of the pupillary response measurements were evaluated using area under receiver operating characteristic (ROC) curves (AUC) and sensitivities at fixed specificities. Influence of inter-eye asymmetry in glaucoma [inter-eye mean deviation (MD) difference on visual fields (VF)] on the diagnostic ability of pupillography parameters was evaluated by ROC regression approach. The AUCs of automated pupillography parameters ranged from 0.60 (amplitude score with peripheral blue stimulus) to 0.82 (amplitude score with full field white stimulus, Amp-FF-W). Sensitivity at 95% specificity ranged between 5% (amplitude score with full field blue stimulus) and 45% (amplitude score with full field green stimulus). Inter-eye MD difference significantly affected the diagnostic performance of automated pupillography parameters (p < 0.05). AUCs of Amp-FF-W at inter-eye MD difference of 0 dB, 5 dB, 10 dB and 15 dB were 0.71, 0.80, 0.87 and 0.93, respectively, according to the regression model. The corresponding sensitivities at 95% specificity were 20%, 34%, 50% and 66%, respectively. The diagnostic abilities of even the best automated pupillography parameters were only moderate in glaucoma. The performance of these pupillography measurements in detecting glaucoma significantly increased with greater inter-eye asymmetry in the glaucomatous damage.

  12. Non-animal sensitization testing: state-of-the-art.

    PubMed

    Vandebriel, Rob J; van Loveren, Henk

    2010-05-01

    Predictive tests to identify the sensitizing properties of chemicals are carried out using animals. In the European Union timelines for phasing out many standard animal tests were established for cosmetics. Following this policy, the new European Chemicals Legislation (REACH) favors alternative methods, if validated and appropriate. In this review the authors aim to provide a state-of-the art overview of alternative methods (in silico, in chemico, and in vitro) to identify contact and respiratory sensitizing capacity and in some occasions give a measure of potency. The past few years have seen major advances in QSAR (quantitative structure-activity relationship) models where especially mechanism-based models have great potential, peptide reactivity assays where multiple parameters can be measured simultaneously, providing a more complete reactivity profile, and cell-based assays. Several cell-based assays are in development, not only using different cell types, but also several specifically developed assays such as three-dimenionally (3D)-reconstituted skin models, an antioxidant response reporter assay, determination of signaling pathways, and gene profiling. Some of these assays show relatively high sensitivity and specificity for a large number of sensitizers and should enter validation (or are indeed entering this process). Integrating multiple assays in a decision tree or integrated testing system is a next step, but has yet to be developed. Adequate risk assessment, however, is likely to require significantly more time and efforts.

  13. Analyses of microstructural and elastic properties of porous SOFC cathodes based on focused ion beam tomography

    NASA Astrophysics Data System (ADS)

    Chen, Zhangwei; Wang, Xin; Giuliani, Finn; Atkinson, Alan

    2015-01-01

    Mechanical properties of porous SOFC electrodes are largely determined by their microstructures. Measurements of the elastic properties and microstructural parameters can be achieved by modelling of the digitally reconstructed 3D volumes based on the real electrode microstructures. However, the reliability of such measurements is greatly dependent on the processing of raw images acquired for reconstruction. In this work, the actual microstructures of La0.6Sr0.4Co0.2Fe0.8O3-δ (LSCF) cathodes sintered at an elevated temperature were reconstructed based on dual-beam FIB/SEM tomography. Key microstructural and elastic parameters were estimated and correlated. Analyses of their sensitivity to the grayscale threshold value applied in the image segmentation were performed. The important microstructural parameters included porosity, tortuosity, specific surface area, particle and pore size distributions, and inter-particle neck size distribution, which may have varying extent of effect on the elastic properties simulated from the microstructures using FEM. Results showed that different threshold value range would result in different degree of sensitivity for a specific parameter. The estimated porosity and tortuosity were more sensitive than surface area to volume ratio. Pore and neck size were found to be less sensitive than particle size. Results also showed that the modulus was essentially sensitive to the porosity which was largely controlled by the threshold value.

  14. The Usefulness of Clinical-Practice-Based Laboratory Data in Facilitating the Diagnosis of Dengue Illness

    PubMed Central

    Liu, Jien-Wei; Lee, Ing-Kit; Wang, Lin; Chen, Rong-Fu; Yang, Kuender D.

    2013-01-01

    Alertness to dengue and making a timely diagnosis is extremely important in the treatment of dengue and containment of dengue epidemics. We evaluated the complementary role of clinical-practice-based laboratory data in facilitating suspicion/diagnosis of dengue. One hundred overall dengue (57 dengue fever [DF] and 43 dengue hemorrhagic fever [DHF]) cases and another 100 nondengue cases (78 viral infections other than dengue, 6 bacterial sepsis, and 16 miscellaneous diseases) were analyzed. We separately compared individual laboratory variables (platelet count [PC] , prothrombin time [PT], activated partial thromboplastin time [APTT], alanine aminotransferase [ALT], and aspartate aminotransferase [AST]) and varied combined variables of DF and/or DHF cases with the corresponding ones of nondengue cases. The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) in the diagnosis of DF and/or DHF were measured based on these laboratory variables. While trade-off between sensitivity and specificity, and/or suboptimal PPV/NPV was found at measurements using these variables, prolonged APTT + normal PT + PC < 100 × 109 cells/L had a favorable sensitivity, specificity, PPV, and NPV in diagnosis of DF and/or DHF. In conclusion, these data suggested that prolonged APTT + normal PT + PC < 100 × 109 cells/L is useful in evaluating the likelihood of DF and/or DHF. PMID:24455678

  15. The Generalized Anxiety Disorder 7-item scale in adolescents with generalized anxiety disorder: Signal detection and validation.

    PubMed

    Mossman, Sarah A; Luft, Marissa J; Schroeder, Heidi K; Varney, Sara T; Fleck, David E; Barzman, Drew H; Gilman, Richard; DelBello, Melissa P; Strawn, Jeffrey R

    2017-11-01

    In pediatric patients with anxiety disorders, existing symptom inventories are either not freely available or require extensive time and effort to administer. We sought to evaluate a brief self-report scale-the Generalized Anxiety Disorder 7-item scale (GAD-7)-in adolescents with generalized anxiety disorder (GAD). The Pediatric Anxiety Rating Scale (PARS) and the GAD-7 were administered to youth with GAD (confirmed by structured interview). Relationships between the measures were assessed, and sensitivity and specificity was determined with regard to a global symptom severity measure (Clinical Global Impression-Severity). In adolescents with GAD (N = 40; mean age, 14.8 ± 2.8), PARS and GAD-7 scores strongly correlated (R = 0.65, P ≤ .001) and a main effect for symptom severity was observed (P ≤ .001). GAD-7 scores ≥11 and ≥17 represented the optimum specificity and sensitivity for detecting moderate and severe anxiety, respectively. The PARS and GAD-7 similarly reflect symptom severity. The GAD-7 is associated with acceptable specificity and sensitivity for detecting clinically significant anxiety symptoms. GAD-7 scores may be used to assess anxiety symptoms and to differentiate between mild and moderate GAD in adolescents, and may be more efficient than the PARS.

  16. Validity of LIDAS (LIfetime Depression Assessment Self-report): a self-report online assessment of lifetime major depressive disorder.

    PubMed

    Bot, M; Middeldorp, C M; de Geus, E J C; Lau, H M; Sinke, M; van Nieuwenhuizen, B; Smit, J H; Boomsma, D I; Penninx, B W J H

    2017-01-01

    There is a paucity of valid, brief instruments for the assessment of lifetime major depressive disorder (MDD) that can be used in, for example, large-scale genomics, imaging or biomarker studies on depression. We developed the LIfetime Depression Assessment Self-report (LIDAS), which assesses lifetime MDD diagnosis according to DSM criteria, and is largely based on the widely used Composite International Diagnostic Interview (CIDI). Here, we tested the feasibility and determined the sensitivity and specificity for measuring lifetime MDD with this new questionnaire, with a regular CIDI as reference. Sensitivity and specificity analyses of the online lifetime MDD questionnaire were performed in adults with (n = 177) and without (n = 87) lifetime MDD according to regular index CIDIs, selected from the Netherlands Study of Depression and Anxiety (NESDA) and Netherlands Twin Register (NTR). Feasibility was tested in an additional non-selective, population-based sample of NTR participants (n = 245). Of the 753 invited persons, 509 (68%) completed the LIDAS, of which 419 (82%) did this online. User-friendliness of the instrument was rated high. Median completion time was 6.2 min. Sensitivity and specificity for lifetime MDD were 85% [95% confidence interval (CI) 80-91%] and 80% (95% CI 72-89%), respectively. This LIDAS instrument gave a lifetime MDD prevalence of 20.8% in the population-based sample. Measuring lifetime MDD with an online instrument was feasible. Sensitivity and specificity were adequate. The instrument gave a prevalence of lifetime MDD in line with reported population prevalences. LIDAS is a promising tool for rapid determination of lifetime MDD status in large samples, such as needed for genomics studies.

  17. Cross-national comparison of screening mammography accuracy measures in U.S., Norway, and Spain.

    PubMed

    Domingo, Laia; Hofvind, Solveig; Hubbard, Rebecca A; Román, Marta; Benkeser, David; Sala, Maria; Castells, Xavier

    2016-08-01

    To compare accuracy measures for mammographic screening in Norway, Spain, and the US. Information from women aged 50-69 years who underwent mammographic screening 1996-2009 in the US (898,418 women), Norway (527,464), and Spain (517,317) was included. Screen-detected cancer, interval cancer, and the false-positive rates, sensitivity, specificity, positive predictive value (PPV) for recalls (PPV-1), PPV for biopsies (PPV-2), 1/PPV-1 and 1/PPV-2 were computed for each country. Analyses were stratified by age, screening history, time since last screening, calendar year, and mammography modality. The rate of screen-detected cancers was 4.5, 5.5, and 4.0 per 1000 screening exams in the US, Norway, and Spain respectively. The highest sensitivity and lowest specificity were reported in the US (83.1 % and 91.3 %, respectively), followed by Spain (79.0 % and 96.2 %) and Norway (75.5 % and 97.1 %). In Norway, Spain and the US, PPV-1 was 16.4 %, 9.8 %, and 4.9 %, and PPV-2 was 39.4 %, 38.9 %, and 25.9 %, respectively. The number of women needed to recall to detect one cancer was 20.3, 6.1, and 10.2 in the US, Norway, and Spain, respectively. Differences were found across countries, suggesting that opportunistic screening may translate into higher sensitivity at the cost of lower specificity and PPV. • Positive predictive value is higher in population-based screening programmes in Spain and Norway. • Opportunistic mammography screening in the US has lower positive predictive value. • Screening settings in the US translate into higher sensitivity and lower specificity. • The clinical burden may be higher for women screened opportunistically.

  18. Apparent diffusion coefficient on magnetic resonance imaging (MRI) in bladder cancer: relations with recurrence/progression risk

    PubMed Central

    Kikuchi, Ken; Shigihara, Takeshi; Hashimoto, Yuko; Miyajima, Masayuki; Haga, Nobuhiro; Kojima, Yoshiyuki; Shishido, Fumio

    2017-01-01

    Abstract AIMS: To evaluate the relationship between the apparent diffusion coefficient (ADC) value for bladder cancer and the recurrence/progression risk of post-transurethral resection (TUR). METHODS: Forty-one patients with initial and non-muscle-invasive bladder cancer underwent MRI from 2009 to 2012. Two radiologists measured ADC values. A pathologist calculated the recurrence/progression scores, and risk was classified based on the scores. Pearson’s correlation was used to analyze the correlations of ADC value with each score and with each risk group, and the optimal cut-off value was established based on receiver operating characteristic (ROC) curve analysis. Furthermore, the relationship between actual recurrence / progression of cases and ADC values was examined by Unpaird U test. RESULTS: There were significant correlations between ADC value and the recurrence score as well as the progression score (P<0.01, P<0.01, respectively). There were also significant correlations between ADC value and the recurrence risk group as well as progression risk group (P=0.042, P<0.01, respectively). The ADC cut-off value on ROC analysis was 1.365 (sensitivity 100%; specificity 97.4%) for the low and intermediate recurrence risk groups, 1.024 (sensitivity 47.4%; specificity 100%) for the intermediate and high recurrence risk groups, 1.252 (sensitivity 83.3%; specificity 81.3%) for the low and intermediate progression risk groups, and 0.955 (sensitivity 87.5%; specificity 63.2%) between the intermediate and high progression risk groups. The difference between the ADC values of the recurrence and nonrecurrence group in Unpaired t test was significant (P<0.05). CONCLUSION: ADC on MRI in bladder cancer could potentially be useful, non-invasive measurement for estimating the risks of recurrence and progression. PMID:28680010

  19. The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors.

    PubMed

    Rangel, Alejandra; Palte, Gesa; Dunscombe, Peter

    2010-07-01

    Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. 9 head and neck (H&N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets (+/- 1 mm in two banks, +/- 0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H&N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

  20. Evaluation of vaginal pH for detection of bacterial vaginosis

    PubMed Central

    Hemalatha, R.; Ramalaxmi, Baru Anantha; Swetha, Eluru; Balakrishna, N.; Mastromarino, Paola

    2013-01-01

    Background & objectives: Bacterial vaginosis (BV) is highly prevalent among women in reproductive age group. Little information exists on routine vaginal pH measurement in women with BV. We undertook this study to assess the utility of vaginal pH determination for initial evaluation of bacterial vaginosis. Methods: In this cross-sectional study vaginal swabs were collected from women with complaints of white discharge, back ache and pain abdomen attending a government hospital and a community health clinic, and subjected to vaginal pH determination, Gram stain, wet mount and whiff test. Nugent score and Amsel criteria were used for BV confirmation. Results: Of the 270 women included in the analysis, 154 had BV based on Nugents’ score. The mean vaginal pH in women with BV measured by pH strips and pH glove was 5 and 4.9, respectively. The vaginal pH was significantly higher in women with BV. Vaginal discharge was prevalent in 84.8 per cent women, however, only 56.8 per cent of these actually had BV by Nugent score (NS). Presence of clue cells and positive whiff test were significant for BV. Vaginal pH >4.5 by pH strips and pH Glove had a sensitivity of 72 and 79 per cent and specificity of 60 and 53 per cent, respectively to detect BV. Among the combination criteria, clue cells and glove pH >4.5 had highest sensitivity and specificity to detect BV. Interpretation & conclusions: Vaginal pH determination is relatively sensitive, but less specific in detecting women with BV. Inclusion of whiff test along with pH test reduced the sensitivity, but improved specificity. Both, the pH strip and pH glove are equally suitable for screening women with BV on outpatient basis. PMID:24135180

  1. Obesity in Korean pre-adolescent school children: comparison of various anthropometric measurements based on bioelectrical impedance analysis.

    PubMed

    Yoo, S; Lee, S-Y; Kim, K-N; Sung, E

    2006-07-01

    To examine the relationships between body mass index (BMI), percentage-weight-for-height (PWH) and percentage body fat (PBF), and to compare their validity based on PBF with the BMI criteria of International Obesity Task Force (IOTF) for childhood obesity in Korean pre-adolescent school children. Statistical comparative analysis for anthropometric measures. Korean pre-adolescent children (438 boys and 454 girls, aged 8-12 years, mean BMI 19.5+/-3.4 kg/m2). Body mass index and PWH were calculated as body size indices from height and weight. Hand-to-foot bioelectrical impedance analysis (BIA) was performed to obtain PBF values, with obese children defined as PBF above 35%. Sensitivity and specificity were displayed with the gold standard of PBF, and receiver operating characteristic (ROC) curves were used to assess the performance of BMI and PWH in detecting obesity. The prevalence of obesity varied by the criteria: 18.8% by Korean BMI standards for 95 percentile, 11% by the IOTF-BMI 30 kg/m2 and 29.4% by Korean PWH cutoffs. Body mass index and PWH were significantly correlated with PBF after adjusting for age, 0.910 (P<0.01) and 0.915 (P<0.01), respectively. The sensitivity and specificity of the PWH cutoffs were 0.909 and 0.882, respectively. The local BMI 95 percentiles had lower sensitivity (0.714) and specificity (0.790). The IOTF-BMI definition showed much lower sensitivity (0.457) and higher specificity (0.990). The BMI cutoffs corresponding with the highest accuracy were smaller than IOTF-BMI 30 kg/m2 for all age groups in both boys and girls. The prevalence of obesity among Korean pre-adolescent children widely varied according to the diagnostic criteria applied. Universally recommended cutoffs for children by IOTF showed the lowest sensitivity among the criteria used, and may therefore underestimate obesity in this population.

  2. Sensitivity and specificity of visual clinical assessment as compared to WHO 2006 standard and NCHS 1977 reference in measuring the growth status of Malaysian infants.

    PubMed

    Selamat, Rusidah; Zain, Fuziah; Raib, Junidah; Zakaria, Rosini; Marzuki, Mohd Shaffari; Ibrahim, Taziah Fatimah

    2011-12-01

    To study the validity of the visual clinical assessment of weight relative to length and length relative to age as compared to the World Health Organization (WHO) 2006 standard and National Center for Health Statistics (NCHS) 1977 reference in asssessing the physical growth of children younger than 1 year. A prospective cohort study was carried out among 684 infants attending goverment health clinics in 2 states in Malaysia. Body weight, length, and clinical assessment were measured on the same day for 9 visits, scheduled every month until 6 months of age and every 2 months until 12 months of age. All of the 3 z-scores for weight for age (WAZ), length for age (HAZ), and weight for length (WHZ) were calculated using WHO Anthro for Personal Computers software. The average sensitivity and specificity for the visual clinical assessment for the detection of thinness were higher using the WHO 2006 standard as compared with using NCHS 1977. However, the overall sensitivity of the visual clinical assessment for the detection of thin and lean children was lower from 1 month of age until a year as compared with the WHO 2006 standard and NCHS 1977 reference. The positive predictive value (PPV) for the visual clinical assessment versus the WHO 2006 standard was almost doubled as compared with the PPV of visual clinical assessment versus the NCHS 1977 reference. The overall average sensitivity, specificity, PPV, and negative predictive value for the detection of stunting was higher for visual clinical assessment versus the WHO 2006 standard as compared with visual clinical assessment versus the NCHS 1977 reference. The sensitivity and specificity of visual clinical assessment for the detection of wasting and stunting among infants are better for the WHO 2006 standard than the NCHS 1977 reference.

  3. The search for an elusive cutoff remains: Problems of binary classification of heavy drinking as an endpoint for alcohol clinical trials.

    PubMed

    Pearson, Matthew R; Bravo, Adrian J; Kirouac, Megan; Witkiewitz, Katie

    2017-02-01

    To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n=1726) and COMBINE (n=1383). In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. The Search for an Elusive Cutoff Remains: Problems of Binary Classification of Heavy Drinking as an Endpoint for Alcohol Clinical Trials

    PubMed Central

    Pearson, Matthew R.; Bravo, Adrian J.; Kirouac, Megan; Witkiewitz, Katie

    2017-01-01

    Background To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. Methods We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n = 1,726) and COMBINE (n = 1,383). Results In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. Conclusions These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. PMID:28038361

  5. Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI.

    PubMed

    Kondo, Takashi; Kobayashi, Daisuke; Mochizuki, Maki; Asanuma, Kouichi; Takahashi, Satoshi

    2017-01-01

    Background Recently developed reagents for the highly sensitive measurement of cardiac troponin I are useful for early diagnosis of acute coronary syndrome. However, differences in measured values between these new reagents and previously used reagents have not been well studied. In this study, we aimed to compare the values between ARCHITECT High-Sensitive Troponin I ST (newly developed reagents), ARCHITECT Troponin I ST and STACIA CLEIA cardiac troponin I (two previously developed reagent kits). Methods Gel filtration high-performance liquid chromatography was used to analyse the causes of differences in measured values. Results The measured values differed between ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cardiac troponin I reagents (r = 0.82). Cross-reactivity tests using plasma with added skeletal-muscle troponin I resulted in higher reactivity (2.17-3.03%) for the STACIA CLEIA cardiac troponin I reagents compared with that for the ARCHITECT High-Sensitive Troponin I ST reagents (less than 0.014%). In addition, analysis of three representative samples using gel filtration high-performance liquid chromatography revealed reagent-specific differences in the reactivity against each cardiac troponin I complex; this could explain the differences in values observed for some of the samples. Conclusion The newly developed ARCHITECT High-Sensitive Troponin I ST reagents were not affected by the presence of skeletal-muscle troponin I in the blood and may be useful for routine examinations.

  6. IMRT QA: Selecting gamma criteria based on error detection sensitivity.

    PubMed

    Steers, Jennifer M; Fraass, Benedick A

    2016-04-01

    The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose threshold was consistent across all studied combinations of %Diff/DTA. Criteria such as 2%/3 mm and 3%/2 mm with a 50% threshold at 90% pixels passing are shown to be more appropriately sensitive without being overly strict. However, a broadening of the penumbra by as much as 5 mm in the beam configuration was difficult to detect with commonly used criteria, as well as with the previously mentioned criteria utilizing a threshold of 50%. We have introduced the error curve method, an analysis technique which allows the quantitative determination of gamma criteria sensitivity to induced errors. The application of the error curve method using DMLC IMRT plans measured on the ArcCHECK® device demonstrated that large errors can potentially be missed in IMRT QA with commonly used gamma criteria (e.g., 3%/3 mm, threshold = 10%, 90% pixels passing). Additionally, increasing the dose threshold value can offer dramatic increases in error sensitivity. This approach may allow the selection of more meaningful gamma criteria for IMRT QA and is straightforward to apply to other combinations of devices and treatment techniques.

  7. [What is hidden behind the Baking Tray Task? Study of sensibility and specificity in right-hemispheric stroke patients].

    PubMed

    Garcia-Fernandez, Juan; Garcia-Molina, Alberto; Aparicio-Lopez, Celeste; Sanchez-Carrion, Rocío; Ensenat, Antònia; Pena-Casanova, Jordi; Roig-Rovira, Teresa

    2015-12-16

    Tham and Tegner proposed the Baking Tray Task (BTT) as a fast simple assessment test for detecting spatial negligence. However, very few studies have examined its validity as a diagnostic test. To analyse the diagnostic validity of the BTT by measuring its specificity and sensitivity in a sample of subjects with right hemisphere strokes. Forty-eight patients with right hemisphere vascular lesions were distributed in two groups (negligence group, n = 35; non-negligence group, n = 13) according to the scores obtained in a battery of visuospatial examination tests. The participants' performance on the BTT was compared with that of a healthy control group (n = 12). The results showed a high level of sensitivity of the BTT, but low specificity. The performance on the BTT of eight of the 13 members of the non-negligence group was suggestive of negligence. The BTT has proved to be a sensitive test for the detection of spatial negligence. Yet, based on its low specificity, its use alone as a single diagnostic test is not recommended.

  8. Electrochemistry-based Approaches to Low Cost, High Sensitivity, Automated, Multiplexed Protein Immunoassays for Cancer Diagnostics

    PubMed Central

    Dixit, Chandra K.; Kadimisetty, Karteek; Otieno, Brunah A.; Tang, Chi; Malla, Spundana; Krause, Colleen E.; Rusling, James F.

    2015-01-01

    Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. Simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that doesn’t require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for highly sensitive detection of the panel of cancer-specific biomarkers with high specificity and at the same time have the potential to be translated into a POC. PMID:26525998

  9. Electrochemistry-based approaches to low cost, high sensitivity, automated, multiplexed protein immunoassays for cancer diagnostics.

    PubMed

    Dixit, Chandra K; Kadimisetty, Karteek; Otieno, Brunah A; Tang, Chi; Malla, Spundana; Krause, Colleen E; Rusling, James F

    2016-01-21

    Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. The simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that does not require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for the highly sensitive detection of a panel of cancer-specific biomarkers with high specificity which at the same time has the potential to be translated into POC applications.

  10. Sensitivity and specificity of Norwegian optometrists' evaluation of diabetic retinopathy in single-field retinal images - a cross-sectional experimental study.

    PubMed

    Sundling, Vibeke; Gulbrandsen, Pål; Straand, Jørund

    2013-01-10

    In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a "gold standard", images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education.

  11. Sensitivity and specificity of Norwegian optometrists’ evaluation of diabetic retinopathy in single-field retinal images – a cross-sectional experimental study

    PubMed Central

    2013-01-01

    Background In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. Methods This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a “gold standard”, images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). Results The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. Conclusions The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education. PMID:23305337

  12. Identification of beta cell dysfunction at the pre-symptomatic stage of diabetes mellitus by novel analytical system: liquid biopsy measurements in femtograms.

    PubMed

    Krapfenbauer, Kurt

    2017-12-01

    Diabetes mellitus is produced and progresses as a consequence of complex and gradual processes, in which a variety of alterations of the endocrine pancreas, are involved and which mainly result in beta cell failure. Those molecular alterations can be found in the bloodstream, which suggests that we could quantify specific biomarkers in plasma or serum by very sensitive methods before the onset diabetes mellitus is diagnosed. However, classical methods of protein analysis such as electrophoresis, Western blot, ELISA, and liquid chromatography are generally time-consuming, lab-intensive, and not sensitive enough to detect such alteration in a pre-symptomatic state of the disease. A very sensitive and novel analytical detection conjugate system by using the combination of polyfluorophor technology with protein microchip method was developed. This innovative system facilitates the use of a very sensitive microchip assays that measure selected biomarkers in a small sample volume (10 μL) with a much higher sensitivity (92%) compare to common immune assay systems. Further advances of the application of this technology combine the power of miniaturization and faster quantification (around 10 min). The power of this technology offers great promise for point-of-care clinical testing and monitoring of specific biomarkers for diabetes in femtogram level in serum or plasma. In conclusion, the results indicate that the technical performance of this new technology is valid and that the assay is able to quantified PPY-specific antigens in plasma at femtogram levels which can be used for identification of beta cell dysfunction at the pre-symptomatic stage of diabetes mellitus.

  13. Predicting refeeding hypophosphataemia: insulin growth factor 1 (IGF-1) as a diagnostic biochemical marker for clinical practice.

    PubMed

    Goyale, Atul; Ashley, Sarah L; Taylor, David R; Elnenaei, Manal O; Alaghband-Zadeh, Jamshid; Sherwood, Roy A; le Roux, Carel W; Vincent, Royce P

    2015-01-01

    Refeeding syndrome (RS) is a potentially fatal condition that can occur following the re-introduction of nutrition after a period of starvation. Hypophosphataemia following the reintroduction of nutrition is often the only reliable biochemical marker of RS. Refeeding index (RI) generated from baseline insulin-like growth factor-1 (IGF-1) and leptin has been proposed as a useful biochemical marker for the identification of patients at risk of developing refeeding hypophosphataemia (RH). A prospective study included 52 patients referred for parenteral nutrition (PN). The sensitivity and specificity of IGF-1 measured using a sensitive assay was compared to the RI in predicting the development of RH (a ≥ 30% drop in PO4 during the first 36-h of PN administration). Leptin and IGF-1 were analysed on baseline samples using a quantitative enzyme-linked immunoassay. Daily blood samples were collected from all patients for routine biochemistry for the full duration of PN administration. High sensitivity IGF-1 measurement alone was comparable with the RI, using receiver-operating characteristic (ROC) curve analysis, with areas under the curve being 0.79 and 0.80, respectively, and superior to leptin alone (0.72) for predicting ≥ 30% drop in PO4. The cut-off value for IGF-1 that gave best sensitivity (91% [95% CI 75-98%]) and specificity (65% [95% CI 41-85%]) was 63.7 µg/L, with a likelihood ratio of 2.59. Baseline IGF-1 is an objective, sensitive and specific biochemical marker in identifying patients who are at high risk of developing RH prior to PN administration and therefore may have a role in clinical practice. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Determination of the diagnostic value of the Modified Mallampati Score, Upper Lip Bite Test and Facial Angle in predicting difficult intubation: A prospective descriptive study.

    PubMed

    Mahmoodpoor, Ata; Soleimanpour, Hassan; Golzari, Samad Ej; Nejabatian, Arezoo; Pourlak, Tannaz; Amani, Masoumeh; Hajmohammadi, Saeed; Hosseinzadeh, Hamzeh; Esfanjani, Robab Mehdizadeh

    2017-02-01

    Difficult intubation is a significant cause of mortality and morbidity related to anesthesia. We decided to evaluate the value of Modified Mallampati Score, Upper Lip Bite Test and Facial Angle in the prediction of difficult intubation. In a prospective descriptive study, data from 132 patients who were candidates for elective maxillofacial surgeries under general anesthesia were gathered. Facial Angles were measured by a maxillofacial surgeon according to cephalometry. The Modified Mallampati Score and Upper Lip Bite Test were first measured by an anesthesiologist and then another anesthesiologist was assigned to record the Cormack and Lehane score during the intubation. Grades 3 and 4 were considered as difficult intubation. Sensitivity, specificity, positive predictive value, negative predictive value and Youden index were calculated for all tests. Difficult intubation was reported in 12% of the patients. Facial Angle≤82.5° can predict difficult intubation with 87.5% sensitivity and 88.8% specificity. Among the three tests, a high Modified Mallampati Score had the highest specificity (94.5%) and a high Modified Mallampati Score and Facial Angle (FA≤82.5°) had the highest sensitivity (87.5%). The highest NPV, sensitivity and Youden index were observed when using Facial Angle with the Modified Mallampati Score or with Upper Lip Bite Test. Facial Angle has a high sensitivity, NPV and Youden index for the prediction of difficult intubation, but the best result is achieved when Facial Angle is used in combination with either the Modified Mallampati Score or Upper Lip Bit Test. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Automated imaging technologies for the diagnosis of glaucoma: a comparative diagnostic study for the evaluation of the diagnostic accuracy, performance as triage tests and cost-effectiveness (GATE study).

    PubMed

    Azuara-Blanco, Augusto; Banister, Katie; Boachie, Charles; McMeekin, Peter; Gray, Joanne; Burr, Jennifer; Bourne, Rupert; Garway-Heath, David; Batterbury, Mark; Hernández, Rodolfo; McPherson, Gladys; Ramsay, Craig; Cook, Jonathan

    2016-01-01

    Many glaucoma referrals from the community to hospital eye services are unnecessary. Imaging technologies can potentially be useful to triage this population. To assess the diagnostic performance and cost-effectiveness of imaging technologies as triage tests for identifying people with glaucoma. Within-patient comparative diagnostic accuracy study. Markov economic model comparing the cost-effectiveness of a triage test with usual care. Secondary care. Adults referred from the community to hospital eye services for possible glaucoma. Heidelberg Retinal Tomography (HRT), including two diagnostic algorithms, glaucoma probability score (HRT-GPS) and Moorfields regression analysis (HRT-MRA); scanning laser polarimetry [glaucoma diagnostics (GDx)]; and optical coherence tomography (OCT). The reference standard was clinical examination by a consultant ophthalmologist with glaucoma expertise including visual field testing and intraocular pressure (IOP) measurement. (1) Diagnostic performance of imaging, using data from the eye with most severe disease. (2) Composite triage test performance (imaging test, IOP measurement and visual acuity measurement), using data from both eyes, in correctly identifying clinical management decisions, that is 'discharge' or 'do not discharge'. Outcome measures were sensitivity, specificity and incremental cost per quality-adjusted life-year (QALY). Data from 943 of 955 participants were included in the analysis. The average age was 60.5 years (standard deviation 13.8 years) and 51.1% were females. Glaucoma was diagnosed by the clinician in at least one eye in 16.8% of participants; 37.9% of participants were discharged after the first visit. Regarding diagnosing glaucoma, HRT-MRA had the highest sensitivity [87.0%, 95% confidence interval (CI) 80.2% to 92.1%] but the lowest specificity (63.9%, 95% CI 60.2% to 67.4%) and GDx had the lowest sensitivity (35.1%, 95% CI 27.0% to 43.8%) but the highest specificity (97.2%, 95% CI 95.6% to 98.3%). HRT-GPS had sensitivity of 81.5% (95% CI 73.9% to 87.6%) and specificity of 67.7% (95% CI 64.2% to 71.2%) and OCT had sensitivity of 76.9% (95% CI 69.2% to 83.4%) and specificity of 78.5% (95% CI 75.4% to 81.4%). Regarding triage accuracy, triage using HRT-GPS had the highest sensitivity (86.0%, 95% CI 82.8% to 88.7%) but the lowest specificity (39.1%, 95% CI 34.0% to 44.5%), GDx had the lowest sensitivity (64.7%, 95% CI 60.7% to 68.7%) but the highest specificity (53.6%, 95% CI 48.2% to 58.9%). Introducing a composite triage station into the referral pathway to identify appropriate referrals was cost-effective. All triage strategies resulted in a cost reduction compared with standard care (consultant-led diagnosis) but with an associated reduction in effectiveness. GDx was the least costly and least effective strategy. OCT and HRT-GPS were not cost-effective. Compared with GDx, the cost per QALY gained for HRT-MRA is £22,904. The cost per QALY gained with current practice is £156,985 compared with HRT-MRA. Large savings could be made by implementing HRT-MRA but some benefit to patients will be forgone. The results were sensitive to the triage costs. Automated imaging can be effective to aid glaucoma diagnosis among individuals referred from the community to hospital eye services. A model of care using a triage composite test appears to be cost-effective. There are uncertainties about glaucoma progression under routine care and the cost of providing health care. The acceptability of implementing a triage test needs to be explored. The National Institute for Health Research Health Technology Assessment programme.

  16. Quantitation of Na+, K+-atpase Enzymatic Activity in Tissues of the Mammalian Vestibular System

    NASA Technical Reports Server (NTRS)

    Kerr, T. P.

    1985-01-01

    In order to quantify vestibular Na(+), K(+)-ATPase, a microassay technique was developed which is sufficiently sensitive to measure the enzymatic activity in tissue from a single animal. The assay was used to characterize ATPase in he vestibular apparatus of the Mongolian gerbil. The quantitative procedure employs NPP (5 mM) as synthetic enzyme substrate. The assay relies upon spectrophotometric measurement (410 nm) of nitrophenol (NP) released by enzymatic hydrolysis of the substrate. Product formation in the absence of ouabain reflects both specific (Na(+), K(+)-ATPase) and non-specific (Mg(++)-ATPase) enzymatic activity. By measuring the accumulation of reaction product (NP) at three-minute intervals during the course of incubation, it is found that the overall enzymatic reaction proceeds linearly for at least 45 minutes. It is therefore possible to determine two separate reaction rates from a single set of tissues. Initial results indicate that total activity amounts to 53.3 + or - 11.2 (S.E.M.) nmol/hr/mg dry tissue, of which approximately 20% is ouabain-sensitive.

  17. Evaluation of posttransplantation soluble CD30 for diagnosis of acute renal allograft rejection.

    PubMed

    Pelzl, Steffen; Opelz, Gerhard; Daniel, Volker; Wiesel, Manfred; Süsal, Caner

    2003-02-15

    Posttransplantation measurement of soluble CD30 (sCD30) may be useful for identifying kidney graft recipients at risk of impending graft rejection in the early posttransplantation period. We measured plasma sCD30 levels and evaluated the levels in relation to the diagnosis of rejection. Receiver operating characteristic curves demonstrated that on posttransplantation days 3 to 5, sCD30 allowed a differentiation of recipients who subsequently developed acute allograft rejection (n=25) from recipients with an uncomplicated course (n=20, P<0.0001) (area under the receiver operating characteristic curve 0.96, specificity 100%, sensitivity 88%) and recipients with acute tubular necrosis in the absence of rejection (n=11, P=0.001) (area under the receiver operating characteristic curve 0.85, specificity 91%, sensitivity 72%). sCD30 measured on posttransplantation days 3 to 5 offers a noninvasive means for differentiating patients with impending acute allograft rejection from patients with an uncomplicated course or with acute tubular necrosis.

  18. The relationship between the Neuro-Quality of Life Depression and Anxiety Measures and the Personality Assessment Inventory in persons with epilepsy.

    PubMed

    De Marco, Anthony P; Mahoney, James J; Aduen, Paula A; Langer, Jennifer; Bajo, Stephanie D; Broshek, Donna K

    2017-05-01

    To investigate the associations between the Neuro-Quality of Life (NQOL) Depression and Anxiety measures with an objective emotional inventory (Personality Assessment Inventory; PAI), and demonstrate the clinical utility of the NQOL as screening measures for depression and anxiety in persons with epilepsy (PWE). PWE (N=72) were concurrently administered the NQOL Depression and Anxiety measures and the PAI. Pearson product moment correlations were used to determine the relationships between the NQOL measures and the respective PAI scales (i.e., depression, anxiety). One-way ANOVAs were conducted comparing NQOL scores between patients with elevated levels of depression and anxiety (T-score≥65 on the PAI) to profiles that were within normal limits. Using sensitivity and specificity analyses, optimal cut-scores on the NQOL measures were determined. Participants were primarily Caucasian (89%), female (60%), and ~35 years old. The NQOL Depression measure was significantly correlated with the PAI Depression total score (r=.747; p<0.001) and its subscales (p's<0.001). Similarly, the NQOL Anxiety measure was significantly correlated with the PAI Anxiety total score (r=.750; p<0.001) and its subscales (p's<0.001). Compared to profiles that were within normal limits, individuals with elevated depressive symptoms on the PAI had significantly higher NQOL Depression scores (F(1,71)=48.2, p<0.001, d=1.6). Similarly, those who endorsed elevated anxiety on the PAI had significantly higher NQOL Anxiety scores (F(1,71)=32.2, p<0.001, d=1.5). Cut-off scores of 19 on the NQOL Depression and 24 on the NQOL Anxiety measures adequately detected depression (sensitivity=0.67; specificity=0.93; PPV=0.91; NPV=0.74) and anxiety symptoms (sensitivity=0.77; specificity=0.82; PPV=0.81; NPV=0.78) in PWE. The NQOL Depression and Anxiety measures evidenced strong associations with the PAI Depression and Anxiety scales and may be effective in detecting depressive and anxiety symptoms in PWE using the provided cut-scores. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Evaluation of immunity to varicella zoster virus with a novel double antigen sandwich enzyme-linked immunosorbent assay.

    PubMed

    Liu, Jian; Chen, Chunye; Zhu, Rui; Ye, Xiangzhong; Jia, Jizong; Yang, Lianwei; Wang, Yongmei; Wang, Wei; Ye, Jianghui; Li, Yimin; Zhu, Hua; Zhao, Qinjian; Zhang, Jun; Cheng, Tong; Xia, Ningshao

    2016-11-01

    Varicella is a highly contagious disease caused by primary infection of Varicella zoster virus (VZV). Varicella can be severe or even lethal in susceptible adults, immunocompromised patients and neonates. Determination of the status of immunity to VZV is recommended for these high-risk populations. Furthermore, measurement of population immunity to VZV can help in developing proper varicella vaccination programmes. VZV glycoprotein E (gE) is an antigen that has been demonstrated to be a highly accurate indicator of VZV-specific immunity. In this study, recombinant gE (rgE) was used to establish a double antigen sandwich enzyme-linked immunosorbent assay (ELISA). The established sandwich ELISA showed high specificity and sensitivity in the detection of human sera, and it could detect VZV-specific antibodies at a concentration of 11.25 m IU/mL with a detection linearity interval of 11.25 to 360 m IU/mL (R 2  = 0.9985). The double gE antigen sandwich ELISA showed a sensitivity of 95.08 % and specificity of 100 % compared to the fluorescent-antibody-to-membrane-antigen (FAMA) test, and it showed a sensitivity of 100 % and a specificity of 94.74 % compared to a commercial neutralizing antibody detection kit. Thus, the established double antigen sandwich ELISA can be used as a sensitive and specific quantitative method to evaluate immunity to VZV.

  20. The Pot Calling the Kettle Black? A Comparison of Measures of Current Tobacco Use

    PubMed Central

    ROSENMAN, ROBERT

    2014-01-01

    Researchers often use the discrepancy between self-reported and biochemically assessed active smoking status to argue that self-reported smoking status is not reliable, ignoring the limitations of biochemically assessed measures and treating it as the gold standard in their comparisons. Here, we employ econometric techniques to compare the accuracy of self-reported and biochemically assessed current tobacco use, taking into account measurement errors with both methods. Our approach allows estimating and comparing the sensitivity and specificity of each measure without directly observing true smoking status. The results, robust to several alternative specifications, suggest that there is no clear reason to think that one measure dominates the other in accuracy. PMID:25587199

  1. Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity at high sensitivity levels (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhao, Jianhua; Zeng, Haishan; Kalia, Sunil; Lui, Harvey

    2017-02-01

    Background: Raman spectroscopy is a non-invasive optical technique which can measure molecular vibrational modes within tissue. A large-scale clinical study (n = 518) has demonstrated that real-time Raman spectroscopy could distinguish malignant from benign skin lesions with good diagnostic accuracy; this was validated by a follow-up independent study (n = 127). Objective: Most of the previous diagnostic algorithms have typically been based on analyzing the full band of the Raman spectra, either in the fingerprint or high wavenumber regions. Our objective in this presentation is to explore wavenumber selection based analysis in Raman spectroscopy for skin cancer diagnosis. Methods: A wavenumber selection algorithm was implemented using variably-sized wavenumber windows, which were determined by the correlation coefficient between wavenumbers. Wavenumber windows were chosen based on accumulated frequency from leave-one-out cross-validated stepwise regression or least and shrinkage selection operator (LASSO). The diagnostic algorithms were then generated from the selected wavenumber windows using multivariate statistical analyses, including principal component and general discriminant analysis (PC-GDA) and partial least squares (PLS). A total cohort of 645 confirmed lesions from 573 patients encompassing skin cancers, precancers and benign skin lesions were included. Lesion measurements were divided into training cohort (n = 518) and testing cohort (n = 127) according to the measurement time. Result: The area under the receiver operating characteristic curve (ROC) improved from 0.861-0.891 to 0.891-0.911 and the diagnostic specificity for sensitivity levels of 0.99-0.90 increased respectively from 0.17-0.65 to 0.20-0.75 by selecting specific wavenumber windows for analysis. Conclusion: Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity at high sensitivity levels.

  2. Digital obstructive arterial disease can be detected by laser Doppler measurements with high sensitivity and specificity.

    PubMed

    Mahe, Guillaume; Liedl, David A; McCarter, Charlene; Shepherd, Roger; Gloviczki, Peter; McPhail, Ian R; Rooke, Thom W; Wennberg, Paul W

    2014-04-01

    This study was conducted to determine the sensitivity and specificity of laser Doppler flowmetry (LDF) measurements for digital obstructive arterial disease (DOAD) using angiography as the reference standard and to compare the accuracy of different classical tests used to assess DOAD. Diagnosis of vascular abnormalities at the digital level is challenging. Angiography is the gold standard for assessment of DOAD but is invasive and expensive to perform. We performed a retrospective analysis of consecutive patients referred at Mayo Clinic (Rochester, Minn) for upper extremity arterial assessment during a 27-month period. Finger-brachial index, skin blood flow (in arbitrary units [a.u.]), and skin temperature (in degrees Celsius) were recorded in each digit on the pulp at baseline and after a thermal challenge test (hand placed in a thermal box at 47.0°C for 15 minutes). Angiogram analysis was blinded and performed by a radiologist using a vascularization scale ranging from 0 (no vessel) to 4 (normal). The receiver operating characteristic curve was used to define a specific cutoff point to detect DOAD. Twenty-two patients had LDF measurements and complete angiograms. A total of 185 digits were analyzed because some patients had only analysis of one hand. The best area under the curve (AUC) was 0.98 (range, 0.94-0.99) for postwarming skin blood flow, with a cutoff point of ≤206 a.u. This AUC was statistically different from AUCs of all the other tests (P < .01). Sensitivity and specificity were 93% (95% confidence interval, 85%-97%) and 96% (95% confidence interval, 90%-99%), respectively. LDF combined with a thermal challenge is highly accurate, safe, and noninvasive means to detect DOAD. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  3. Six-month Follow Up of the Injured Trauma Survivor Screen (ITSS): Clinical Implications and Future Directions.

    PubMed

    Hunt, Joshua C; Chesney, Samantha A; Brasel, Karen; deRoon-Cassini, Terri A

    2018-04-17

    The Injured Trauma Survivor Screen (ITSS) has been shown to predict PTSD and depression risk at one-month after traumatic injury. This study explored the ability of the ITSS to predict chronic distress after injury, as well as the impact of combining the ITSS with an additional screening measure. Patients were enrolled following admission to a Level 1 trauma center. Baseline measurements were collected during initial hospitalization, and follow-up measures were collected an average of 6.5 months after injury. Receiver Operating Characteristic (ROC) curve analyses were run to determine predictive accuracy, controlling for participants who had mental health intervention and for those who experienced additional potentially psychologically traumatic events since their injury event. Utilizing a cut score of 2, the ITSS PTSD scale had a sensitivity of 85.42%, specificity 67.35%, NPV 91.9% and PPV 51.4%. The Combined PTSD risk group (risk positive on the baseline ITSS and the PTSD Checklist for the DSM-5) had a sensitivity of 72.92%, specificity 81.63%, NPV 88.2% and PPV 61.6%. Also utilizing a cut score of 2, the ITSS Depression scale had a sensitivity of 72.50%, specificity 70.29%, NPV 91.1% and PPV 37.9%. The 9-item ITSS, which takes approximately five minutes to administer, is a stable screening tool for predicting those most at risk for PTSD and/or depression six-months after admission to a Level 1 trauma center following traumatic injury. The Combined PTSD risk group data provide evidence that symptom evaluation by a psychologist can improve specificity. These results further inform the recommendation of the American College of Surgeons Committee on Trauma regarding PTSD and depression screening in trauma centers. Prognostic study, Level III.

  4. Epoch-based Entropy for Early Screening of Alzheimer's Disease.

    PubMed

    Houmani, N; Dreyfus, G; Vialatte, F B

    2015-12-01

    In this paper, we introduce a novel entropy measure, termed epoch-based entropy. This measure quantifies disorder of EEG signals both at the time level and spatial level, using local density estimation by a Hidden Markov Model on inter-channel stationary epochs. The investigation is led on a multi-centric EEG database recorded from patients at an early stage of Alzheimer's disease (AD) and age-matched healthy subjects. We investigate the classification performances of this method, its robustness to noise, and its sensitivity to sampling frequency and to variations of hyperparameters. The measure is compared to two alternative complexity measures, Shannon's entropy and correlation dimension. The classification accuracies for the discrimination of AD patients from healthy subjects were estimated using a linear classifier designed on a development dataset, and subsequently tested on an independent test set. Epoch-based entropy reached a classification accuracy of 83% on the test dataset (specificity = 83.3%, sensitivity = 82.3%), outperforming the two other complexity measures. Furthermore, it was shown to be more stable to hyperparameter variations, and less sensitive to noise and sampling frequency disturbances than the other two complexity measures.

  5. Measurement of urinary metanephrines to screen for pheochromocytoma in an unselected hospital referral population.

    PubMed

    Brain, Keith L; Kay, Jonathan; Shine, Brian

    2006-11-01

    Despite the rarity of pheochromocytoma, diagnosis is important because of the dangers of uncontrolled severe hypertension and the availability of very effective surgical treatment. Urinary or plasma catecholamines or catecholamine derivatives are commonly used to screen for pheochromocytomas before imaging, but data from 24-h urinary metanephrine results, patient age, and sex may better predict tumors in populations with a low pretest probability. We retrospectively studied outcomes of an unselected population (1819 patients) referred to a tertiary hospital laboratory for urinary metanephrine testing and investigated the usefulness of some simple derivative measures for detecting pheochromocytoma. We normalized values for urinary 24-h excretion of metanephrine, normetanephrine, and 3-methoxytyramine by dividing by an age- and sex-specific reference range. We then compared pheochromocytoma prediction by the use of products of these normalized measures with the gold standard of biopsy-confirmed tumor. The product of the excretion of normalized metanephrine (nMAD) and normalized normetanephrine (nNMT) (nMAD.nNMT) was a highly sensitive (100%) and specific (99.1%) measure, yielding a positive predictive value of 82%. ROC curves were not improved by including the normalized 3-methoxytyramine concentrations in the product. The test for nMAD.nNMT gave higher sensitivity and specificity than the tests for either substance alone. The test for nMAD.nNMT is a useful measure for identifying pheochromocytoma in a population with a low pretest probability.

  6. eFurniture for home-based frailty detection using artificial neural networks and wireless sensors.

    PubMed

    Chang, Yu-Chuan; Lin, Chung-Chih; Lin, Pei-Hsin; Chen, Chun-Chang; Lee, Ren-Guey; Huang, Jing-Siang; Tsai, Tsai-Hsuan

    2013-02-01

    The purpose of this study is to integrate wireless sensor technologies and artificial neural networks to develop a system to manage personal frailty information automatically. The system consists of five parts: (1) an eScale to measure the subject's reaction time; (2) an eChair to detect slowness in movement, weakness and weight loss; (3) an ePad to measure the subject's balancing ability; (4) an eReach to measure body extension; and (5) a Home-based Information Gateway, which collects all the data and predicts the subject's frailty. Using a furniture-based measuring device to provide home-based measurement means that health checks are not confined to health institutions. We designed two experiments to obtain optimum frailty prediction model and test overall system performance: (1) We developed a three-step process to adjust different parameters to obtain an optimized neural identification network whose parameters include initialization, L.R. dec and L.R. inc. The post-process identification rate increased from 77.85% to 83.22%. (2) We used 149 cases to evaluate the sensitivity and specificity of our frailty prediction algorithm. The sensitivity and specificity of this system are 79.71% and 86.25% respectively. These results show that our system is a high specificity prediction tool that can be used to assess frailty. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. The sensitivity and specificity of touch preparation for rapid diagnosis of invasive fungal sinusitis: A pilot study.

    PubMed

    Schuman, Theodore A; Nguyen, Josephine H; Yelverton, Joshua C; Almenara, Jorge A; Powers, Celeste N

    2018-01-01

    Invasive fungal sinusitis is a morbid pathology that typically affects immunocompromised patients and may quickly progress to fulminant disease. The purpose of this study was to measure the sensitivity and specificity of touch preparation of nasal debridement specimens as a rapid diagnostic tool for invasive fungal sinusitis. A retrospective chart review was performed of 22 patients undergoing nasal debridement due to suspicion for invasive fungal sinusitis over a 10-year period. Thirteen patients had touch preparation of nasal specimens followed by routine histologic processing; 2 of these patients underwent two and 1 patient had three separate debridements, for a total of 17 touch preparations performed. The sensitivity and specificity of touch preparation were calculated by correlating the initial results with the presence of fungal invasion on final pathologic analysis. The sensitivity of touch preparation was 56% (95% confidence interval [CI]: 0.23 to 0.85), specificity was 100% (95% CI: 0.60 to 1.00), positive predictive value was 100% (95% CI: 0.46 to 1.00), and negative predictive value was 67% (95% CI: 0.35 to 0.89). This procedure may be a useful adjunct in situations requiring rapid diagnosis of invasive fungal sinusitis but should not be used as the sole criterion for determining the need for surgical intervention.

  8. Use of shear wave elastography to differentiate benign and malignant breast lesions.

    PubMed

    Çebi Olgun, Deniz; Korkmazer, Bora; Kılıç, Fahrettin; Dikici, Atilla Süleyman; Velidedeoğlu, Mehmet; Aydoğan, Fatih; Kantarcı, Fatih; Yılmaz, Mehmet Halit

    2014-01-01

    We aimed to determine the correlations between the elasticity values of solid breast masses and histopathological findings to define cutoff elasticity values differentiating malignant from benign lesions. A total of 115 solid breast lesions of 109 consecutive patients were evaluated prospectively using shear wave elastography (SWE). Two orthogonal elastographic images of each lesion were obtained. Minimum, mean, and maximum elasticity values were calculated in regions of interest placed over the stiffest areas on the two images; we also calculated mass/fat elasticity ratios. Correlation of elastographic measurements with histopathological results were studied. Eighty-three benign and thirty-two malignant lesions were histopathologically diagnosed. The minimum, mean, and maximum elasticity values, and the mass/fat elasticity ratios of malignant lesions, were significantly higher than those of benign lesions. The cutoff value was 45.7 kPa for mean elasticity (sensitivity, 96%; specificity, 95%), 54.3 kPa for maximum elasticity (sensitivity, 95%; specificity, 94%), 37.1 kPa for minimum elasticity (sensitivity, 96%; specificity, 95%), and 4.6 for the mass/fat elasticity ratio (sensitivity, 97%; specificity, 95%). SWE yields additional valuable quantitative data to ultrasonographic examination on solid breast lesions. SWE may serve as a complementary tool for diagnosis of breast lesions. Long-term clinical studies are required to accurately select lesions requiring biopsy.

  9. A multiplex branched DNA assay for parallel quantitative gene expression profiling.

    PubMed

    Flagella, Michael; Bui, Son; Zheng, Zhi; Nguyen, Cung Tuong; Zhang, Aiguo; Pastor, Larry; Ma, Yunqing; Yang, Wen; Crawford, Kimberly L; McMaster, Gary K; Witney, Frank; Luo, Yuling

    2006-05-01

    We describe a novel method to quantitatively measure messenger RNA (mRNA) expression of multiple genes directly from crude cell lysates and tissue homogenates without the need for RNA purification or target amplification. The multiplex branched DNA (bDNA) assay adapts the bDNA technology to the Luminex fluorescent bead-based platform through the use of cooperative hybridization, which ensures an exceptionally high degree of assay specificity. Using in vitro transcribed RNA as reference standards, we demonstrated that the assay is highly specific, with cross-reactivity less than 0.2%. We also determined that the assay detection sensitivity is 25,000 RNA transcripts with intra- and interplate coefficients of variance of less than 10% and less than 15%, respectively. Using three 10-gene panels designed to measure proinflammatory and apoptosis responses, we demonstrated sensitive and specific multiplex gene expression profiling directly from cell lysates. The gene expression change data demonstrate a high correlation coefficient (R(2)=0.94) compared with measurements obtained using the single-plex bDNA assay. Thus, the multiplex bDNA assay provides a powerful means to quantify the gene expression profile of a defined set of target genes in large sample populations.

  10. The Valued Living Questionnaire: Defining and Measuring Valued Action within a Behavioral Framework

    ERIC Educational Resources Information Center

    Wilson, Kelly G.; Sandoz, Emily K.; Kitchens, Jennifer; Roberts, Miguel

    2010-01-01

    A number of cognitive-behavior therapies now strongly emphasize particular behavioral processes as mediators of clinical change specific to that therapy. This shift in emphasis calls for the development of measures sensitive to changes in the therapies' processes. Among these is acceptance and commitment therapy (ACT), which posits valued living…

  11. Diagnosis of Autism Spectrum Disorders in 2-Year-Olds: A Study of Community Practice

    ERIC Educational Resources Information Center

    Corsello, Christina M.; Akshoomoff, Natacha; Stahmer, Aubyn C.

    2013-01-01

    Background: Longitudinal research studies have demonstrated that experienced clinicians using standardized assessment measures can make a reliable diagnosis of autism spectrum disorders (ASDs) in children under age 3. Limited data are available regarding the sensitivity and specificity of these measures in community settings. The aims of this…

  12. Evaluation of 16 measures of mental workload using a simulated flight task emphasizing mediational activity

    NASA Technical Reports Server (NTRS)

    Wierwille, W. W.; Rahimi, M.; Casali, J. G.

    1985-01-01

    As aircraft and other systems become more automated, a shift is occurring in human operator participation in these systems. This shift is away from manual control and toward activities that tap the higher mental functioning of human operators. Therefore, an experiment was performed in a moving-base flight simulator to assess mediational (cognitive) workload measurement. Specifically, 16 workload estimation techniques were evaluated as to their sensitivity and intrusion in a flight task emphasizing mediational behavior. Task loading, using navigation problems presented on a display, was treated as an independent variable, and workload-measure values were treated as dependent variables. Results indicate that two mediational task measures, two rating scale measures, time estimation, and two eye behavior measures were reliably sensitive to mediational loading. The time estimation measure did, however, intrude on mediational task performance. Several of the remaining measures were completely insensitive to mediational load.

  13. Proteomic biomarkers apolipoprotein A1, truncated transthyretin and connective tissue activating protein III enhance the sensitivity of CA125 for detecting early stage epithelial ovarian cancer.

    PubMed

    Clarke, Charlotte H; Yip, Christine; Badgwell, Donna; Fung, Eric T; Coombes, Kevin R; Zhang, Zhen; Lu, Karen H; Bast, Robert C

    2011-09-01

    The low prevalence of ovarian cancer demands both high sensitivity (>75%) and specificity (99.6%) to achieve a positive predictive value of 10% for successful early detection. Utilizing a two stage strategy where serum marker(s) prompt the performance of transvaginal sonography (TVS) in a limited number (2%) of women could reduce the requisite specificity for serum markers to 98%. We have attempted to improve sensitivity by combining CA125 with proteomic markers. Sera from 41 patients with early stage (I/II) and 51 with late stage (III/IV) epithelial ovarian cancer, 40 with benign disease and 99 healthy individuals, were analyzed to measure 7 proteins [Apolipoprotein A1 (Apo-A1), truncated transthyretin (TT), transferrin, hepcidin, ß-2-microglobulin (ß2M), Connective Tissue Activating Protein III (CTAPIII), and Inter-alpha-trypsin inhibitor heavy chain 4 (ITIH4)]. Statistical models were fit by logistic regression, followed by optimization of factors retained in the models determined by optimizing the Akaike Information Criterion. A validation set included 136 stage I ovarian cancers, 140 benign pelvic masses and 174 healthy controls. In a training set analysis, the 3 most effective biomarkers (Apo-A1, TT and CTAPIII) exhibited 54% sensitivity at 98% specificity, CA125 alone produced 68% sensitivity and the combination increased sensitivity to 88%. In a validation set, the marker panel plus CA125 produced a sensitivity of 84% at 98% specificity (P=0.015, McNemar's test). Combining a panel of proteomic markers with CA125 could provide a first step in a sequential two-stage strategy with TVS for early detection of ovarian cancer. Copyright © 2011. Published by Elsevier Inc.

  14. Proteomic Biomarkers Apolipoprotein A1, Truncated Transthyretin and Connective Tissue Activating Protein III Enhance the Sensitivity of CA125 for Detecting Early Stage Epithelial Ovarian Cancer

    PubMed Central

    Clarke, Charlotte H.; Yip, Christine; Badgwell, Donna; Fung, Eric T.; Coombes, Kevin R.; Zhang, Zhen; Lu, Karen H.; Bast, Robert C.

    2011-01-01

    Objective The low prevalence of ovarian cancer demands both high sensitivity (>75%) and specificity (99.6%) to achieve a positive predictive value of 10% for successful early detection. Utilizing a two stage strategy where serum marker(s) prompt the performance of transvaginal sonography (TVS) in a limited number (2%) of women could reduce the requisite specificity for serum markers to 98%. We have attempted to improve sensitivity by combining CA125 with proteomic markers. Methods Sera from 41 patients with early stage (I/II) and 51 with late stage (III/IV) epithelial ovarian cancer, 40 with benign disease and 99 healthy individuals, were analyzed to measure 7 proteins [Apolipoprotein A1 (Apo-A1), truncated transthyretin (TT), transferrin, hepcidin, ß-2-microglobulin (ß2M), Connective Tissue Activating Protein III (CTAPIII), and Inter-alpha-trypsin inhibitor heavy chain 4 (ITIH4)]. Statistical models were fit by logistic regression, followed by optimization of factors retained in the models determined by optimizing the Akaike Information Criterion. A validation set included 136 stage I ovarian cancers, 140 benign pelvic masses and 174 healthy controls. Results In a training set analysis, the 3 most effective biomarkers (Apo-A1, TT and CTAPIII) exhibited 54% sensitivity at 98% specificity, CA125 alone produced 68% sensitivity and the combination increased sensitivity to 88%. In a validation set, the marker panel plus CA125 produced a sensitivity of 84% at 98% specificity (P= 0.015, McNemar's test). Conclusion Combining a panel of proteomic markers with CA125 could provide a first step in a sequential two-stage strategy with TVS for early detection of ovarian cancer. PMID:21708402

  15. Non-parametric early seizure detection in an animal model of temporal lobe epilepsy

    NASA Astrophysics Data System (ADS)

    Talathi, Sachin S.; Hwang, Dong-Uk; Spano, Mark L.; Simonotto, Jennifer; Furman, Michael D.; Myers, Stephen M.; Winters, Jason T.; Ditto, William L.; Carney, Paul R.

    2008-03-01

    The performance of five non-parametric, univariate seizure detection schemes (embedding delay, Hurst scale, wavelet scale, nonlinear autocorrelation and variance energy) were evaluated as a function of the sampling rate of EEG recordings, the electrode types used for EEG acquisition, and the spatial location of the EEG electrodes in order to determine the applicability of the measures in real-time closed-loop seizure intervention. The criteria chosen for evaluating the performance were high statistical robustness (as determined through the sensitivity and the specificity of a given measure in detecting a seizure) and the lag in seizure detection with respect to the seizure onset time (as determined by visual inspection of the EEG signal by a trained epileptologist). An optimality index was designed to evaluate the overall performance of each measure. For the EEG data recorded with microwire electrode array at a sampling rate of 12 kHz, the wavelet scale measure exhibited better overall performance in terms of its ability to detect a seizure with high optimality index value and high statistics in terms of sensitivity and specificity.

  16. The utility of kindergarten teacher ratings for predicting low academic achievement in first grade.

    PubMed

    Teisl, J T; Mazzocco, M M; Myers, G F

    2001-01-01

    The purpose of this study was to assess the predictive value of kindergarten teachers' ratings of pupils for later first-grade academic achievement. Kindergarten students were rated by their teachers on a variety of variables, including math and reading performance, teacher concerns, and amount of learning relative to peers. These variables were then analyzed with respect to outcome measures for math and reading ability administered in the first grade. The teachers' ratings of academic performance were significantly correlated with scores on the outcome measures. Analyses were also carried out to determine sensitivity, specificity, and predictive values of the different teacher ratings. The results indicated high overall accuracy, sensitivity, specificity, and negative predictive value for the ratings. Positive predictive value tended to be lower. A recommendation to follow from these results is that teacher ratings of this sort be used to determine which children should receive cognitive screening measures to further enhance identification of children at risk for learning disability. However, this recommendation is limited by the lack of empirically supported screening measures for math disability versus well-supported screening tools for reading disability.

  17. Allergy to kiwi: is component-resolved diagnosis in routine clinical practice really impossible?

    PubMed

    Asero, R

    2012-04-01

    Kiwi allergy is frequent and can be the result of sensitization to a number of allergens showing different physicochemical characteristics. Component-resolved diagnosis of kiwi allergy is still unavailable in routine clinical practice. To investigate whether component resolved-diagnosis of kiwi allergy can be, at least in part, carried out by a proper combination of routinely available diagnostic tools. 63 adults with plant food allergy were studied 36 were kiwi-allergic while 27 were kiwi-tolerant and served as controls. Patients and controls underwent SPT with commercial peach and kiwi extracts, and with aprofilin-enriched date palm pollen extract (all by ALK-Abellò), and the measurement of IgE to birch, kiwi, and natural rubber latex. The in-vitro test showed poor sensitivity and specificity, as it scored positive in about 50% of patients and controls irrespective of clinical allergy to kiwi. The kiwi SPT showed overall poor sensitivity; however, it scored negative in all subjects with pollen food-allergy syndrome, was weakly positive in some lipid transfer protein-hypersensitive/kiwi tolerant subjects and in one latex-sensitized subject, and strongly positive in all subjects with primary kiwi sensitization. SPT with this commercial kiwi extract sensitively and specifically detects patients reacting to specific kiwi allergens. This can be useful to detect patients that are at risk of potentially severe reactions, particularly in case of co-sensitization to labile allergens, while we wait that the whole spectrum of kiwi allergens becomes available for routine in-vitro testing.

  18. Thrust performance of unsteady propulsors using a novel measurement system, and corresponding wake patterns

    PubMed Central

    Clark, Richard P.; Smits, Alexander J.

    2009-01-01

    An apparatus is described for the measurement of unsteady thrust and propulsive efficiency produced by biologically inspired oscillating hydrodynamic propulsors. Force measurement is achieved using a strain-gauge-based force transducer, augmented with a lever to amplify or attenuate the applied force and control the measurement sensitivity and natural frequency of vibration. The lever can be used to tune the system to a specific application and it is shown that, using the lever, the stiffness can be made to increase more rapidly than the measurement sensitivity decreases. Efficiency is computed from measurements of the time-averaged power imparted to the fluid. The apparatus is applied to two different propulsors, demonstrating the versatility of the system; wake visualizations are examined, which provide insight into the physical mechanisms of efficient propulsion. PMID:19946574

  19. New serum biomarkers for prostate cancer diagnosis

    PubMed Central

    Chadha, Kailash C.; Miller, Austin; Nair, Bindukumar B.; Schwartz, Stanley A.; Trump, Donald L.; Underwood, Willie

    2014-01-01

    Background Prostate-specific antigen (PSA) is currently used as a biomarker for diagnosis and management of prostate cancer (CaP). However, PSA typically lacks the sensitivity and specificity desired of a diagnostic marker. Objective The goal of this study was to identify an additional biomarker or a panel of biomarkers that is more sensitive and specific than PSA in differentiating benign versus malignant prostate disease and/or localized CaP versus metastatic CaP. Methods Concurrent measurements of circulating interleukin-8 (IL-8), Tumor necrosis factor-α (TNF-α) and soluble tumor necrosis factor-α receptors 1 (sTNFR1) were obtained from four groups of men: (1) Controls (2) with elevated prostate-specific antigen with a negative prostate biopsy (elPSA_negBx) (3) with clinically localized CaP and (4) with castration resistant prostate cancer. Results TNF-α Area under the receiver operating characteristic curve (AUC = 0.93) and sTNFR1 (AUC = 0.97) were strong predictors of elPSA_negBx (vs. CaP). The best predictor of elPSA_negBx vs CaP was sTNFR1 and IL-8 combined (AUC = 0.997). The strongest single predictors of localized versus metastatic CaP were TNF-α (AUC = 0.992) and PSA (AUC = 0.963) levels. Conclusions The specificity and sensitivity of a PSA-based CaP diagnosis can be significantly enhanced by concurrent serum measurements of IL-8, TNF-α and sTNFR1. In view of the concerns about the ability of PSA to distinguish clinically relevant CaP from indolent disease, assessment of these biomarkers in the larger cohort is warranted. PMID:25593898

  20. Ataques de nervios in relation to anxiety sensitivity among island Puerto Ricans.

    PubMed

    Cintrón, Jennifer A; Carter, Michele M; Sbrocco, Tracy

    2005-12-01

    This study investigated the symptom profile of ataques de nervios (ADN) among Puerto Rican volunteers from the community who self-identified as having experienced at least one ataque. As expected, the most commonly reported ataques-specific symptoms were crying, anger, nervousness, and becoming hysterical. Comparing the responses of those with ADN to those with no history of ADN but who reported elevated anxiety sensitivity (AS) indicated that both groups were comparable on measures of depression, state and trait anxiety, and associated panic symptoms. As expected, both groups scored significantly higher on all measures than did participants with no history of ADN and low AS with the exception of the measure of state anxiety. It is unclear, however, whether the overlap in symptom severity between those with ADN and those with elevated anxiety sensitivity indicates that ADN and AS are the same or distinct conditions.

  1. Validation of the use of self-reported hearing loss and the Hearing Handicap Inventory for elderly among rural Indian elderly population.

    PubMed

    Deepthi, R; Kasthuri, Arvind

    2012-01-01

    Hearing loss is a potentially disabling problem among elderly leading to physical and social dysfunction. Though audiometric assessment of hearing loss is considered as gold standard, it is not feasible in community settings. Several questionnaires measuring hearing handicap have been developed. Knowledge regarding applicability of these questionnaires among rural elderly is limited, hence a study was planned to validate single question and Shortened Hearing Handicap Inventory for Elderly (HHIE-S) in detecting hearing loss against pure tone-audiometry among rural Indian elderly. A single question 'do you feel you have a hearing loss?' and the HHIE-S was administered to 175 elderly in two rural areas. Hearing ability was assessed using pure tone audiometry. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of both screening tools were compared with pure tone averages (PTAs) greater than 25, 40 and 55 dB hearing level (mild, moderate and severe hearing loss, respectively). The single question yielded low sensitivity (30.9%) and high specificity (93.9%) for mild hearing loss. Similarly HHIE-S yielded a sensitivity of 26.2% and specificity of 95.9%. Sensitivity with single question increased to 76.2% and specificity decreased to 83.1% with severe hearing loss. Sensitivity with HHIE-S also increased to 76.2% and specificity decreased to 87.7% with severe hearing loss. These hearing screening questionnaires will be useful in identifying more disabling hearing losses among rural elderly which helps in rehabilitation services planning. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Sensitivity and specificity of diagnostic ultrasound in the diagnosis of phrenic neuropathy.

    PubMed

    Boon, Andrea J; Sekiguchi, Hiroshi; Harper, Caitlin J; Strommen, Jeffrey A; Ghahfarokhi, Leili S; Watson, James C; Sorenson, Eric J

    2014-09-30

    To determine the sensitivity and specificity of B-mode ultrasound in the diagnosis of neuromuscular diaphragmatic dysfunction, including phrenic neuropathy. A prospective study of patients with dyspnea referred to the EMG laboratory over a 2-year time frame for evaluation of neuromuscular respiratory failure who were recruited consecutively and examined with ultrasound for possible diaphragm dysfunction. Sonographic outcome measures were absolute thickness of the diaphragm and degree of increased thickness with maximal inspiration. The comparison standard for diagnosis of diaphragm dysfunction was the final clinical diagnosis of clinicians blinded to the diaphragm ultrasound results, but taking into account other diagnostic workup, including chest radiographs, fluoroscopy, phrenic nerve conduction studies, diaphragm EMG, and/or pulmonary function tests. Of 82 patients recruited over a 2-year period, 66 were enrolled in the study. Sixteen patients were excluded because of inconclusive or insufficient reference testing. One hemidiaphragm could not be adequately visualized; therefore, hemidiaphragm assessment was conducted in a total of 131 hemidiaphragms in 66 patients. Of the 82 abnormal hemidiaphragms, 76 had abnormal sonographic findings (atrophy or decreased contractility). Of the 49 normal hemidiaphragms, none had a false-positive ultrasound. Diaphragmatic ultrasound was 93% sensitive and 100% specific for the diagnosis of neuromuscular diaphragmatic dysfunction. B-mode ultrasound imaging of the diaphragm is a highly sensitive and specific tool for diagnosis of neuromuscular diaphragm dysfunction. This study provides Class II evidence that diaphragmatic ultrasound performed by well-trained individuals accurately identifies patients with neuromuscular diaphragmatic respiratory failure (sensitivity 93%; specificity 100%). © 2014 American Academy of Neurology.

  3. Diagnostic utility of F waves in clinically diagnosed patients of carpal tunnel syndrome.

    PubMed

    Joshi, Anand G; Gargate, Ashwini R

    2013-01-01

    Sensory nerve conduction velocity (SNCV) of median nerve measured across the carpal tunnel, difference between distal sensory latencies (DSLs) of median and ulnar nerves and difference between distal motor latencies (DMLs) of median and ulnar nerves are commonly used nerve conduction parameters for diagnosis of carpal tunnel syndrome (CTS). These are having high degree of sensitivity and specificity. Study of median nerve F-wave minimal latency (FWML) and difference between F-wave minimal latencies (FWMLs) of median and ulnar nerves have also been reported to be useful parameters for diagnosis of CTS. However, there is controversy regarding superiority of F-wave study for diagnosis of CTS. So the aim of present study was to compare sensitivity and specificity of median FWML and difference between FWMLs of median and ulnar nerves with that of above mentioned electrophysiological parameters and to find out which parameters are having more sensitivity and specificity, for early diagnosis of CTS. Median and ulnar nerves sensory and motor conduction, median and ulnar nerves F-wave studies were carried out bilaterally in 125 clinically diagnosed patients of carpal tunnel syndrome. These parameters were also studied in 45 age matched controls. Difference between DSLs of median and ulnar nerves, median SNCV and difference between DMLs of median and ulnar nerves were having highest sensitivity and specificity while median FWML and difference between FWMLs of median and ulnar nerves was having lowest sensitivity and specificity for diagnosis of CTS. So in conclusion F-wave study is not superior parameter for diagnosis of CTS.

  4. Detecting anxiety in individuals with Parkinson disease: A systematic review.

    PubMed

    Mele, Bria; Holroyd-Leduc, Jayna; Smith, Eric E; Pringsheim, Tamara; Ismail, Zahinoor; Goodarzi, Zahra

    2018-01-02

    To examine diagnostic accuracy of anxiety detection tools compared with a gold standard in outpatient settings among adults with Parkinson disease (PD). A systematic review was conducted. MEDLINE, EMABASE, PsycINFO, and Cochrane Database of Systematic Reviews were searched to April 7, 2017. Prevalence of anxiety and diagnostic accuracy measures including sensitivity, specificity, and likelihood ratios were gathered. Pooled prevalence of anxiety was calculated using Mantel-Haenszel-weighted DerSimonian and Laird models. A total of 6,300 citations were reviewed with 6 full-text articles included for synthesis. Tools included within this study were the Beck Anxiety Inventory, Geriatric Anxiety Inventory (GAI), Hamilton Anxiety Rating Scale, Hospital Anxiety and Depression Scale-Anxiety, Parkinson's Anxiety Scale (PAS), and Mini-Social Phobia Inventory. Anxiety diagnoses made included generalized anxiety disorder, social phobia, and any anxiety type. Pooled prevalence of anxiety was 30.1% (95% confidence interval 26.1%-34.0%). The GAI had the best-reported sensitivity of 0.86 and specificity of 0.88. The observer-rated PAS had a sensitivity of 0.71 and the highest specificity of 0.91. While there are 6 tools validated for anxiety screening in PD populations, most tools are only validated in single studies. The GAI is brief and easy to use, with a good balance of sensitivity and specificity. The PAS was specifically developed for PD, is brief, and has self-/observer-rated scales, but with lower sensitivity. Health care practitioners involved in PD care need to be aware of available validated tools and choose one that fits their practice. Copyright © 2017 American Academy of Neurology.

  5. Examining gender equity in health policies in a low- (Peru), middle- (Colombia), and high- (Canada) income country in the Americas.

    PubMed

    Stewart, Donna E; Dorado, Linda M; Diaz-Granados, Natalia; Rondon, Marta; Saavedra, Javier; Posada-Villa, Jose; Torres, Yolanda

    2009-12-01

    Gender inequities in health prevail in most countries despite ongoing attempts to eliminate them. Assessment of gender-sensitive health policies can be used to identify country specific progress as well as gaps and issues that need to be addressed to meet health equity goals. This study selected and measured the existence of gender-sensitive health policies in a low- (Peru), middle- (Colombia), and high (Canada)-income country in the Americas. Investigators selected 10 of 20 gender-sensitive health policy indicators and found eight to be feasible to measure in all three countries, although the wording and scope varied. The results from this study inform policy makers and program planners who aim to develop, improve, implement, and monitor national gender-sensitive health policies. Future studies should assess the implementation of policy indicators within countries and assess their performance in increasing gender equity.

  6. ISFET pH Sensitivity: Counter-Ions Play a Key Role.

    PubMed

    Parizi, Kokab B; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H S Philip

    2017-02-02

    The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor.

  7. ISFET pH Sensitivity: Counter-Ions Play a Key Role

    PubMed Central

    Parizi, Kokab B.; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H. S. Philip

    2017-01-01

    The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor. PMID:28150700

  8. Electronic Raman scattering as an ultra-sensitive probe of strain effects in semiconductors.

    PubMed

    Fluegel, Brian; Mialitsin, Aleksej V; Beaton, Daniel A; Reno, John L; Mascarenhas, Angelo

    2015-05-28

    Semiconductor strain engineering has become a critical feature of high-performance electronics because of the significant device performance enhancements that it enables. These improvements, which emerge from strain-induced modifications to the electronic band structure, necessitate new ultra-sensitive tools to probe the strain in semiconductors. Here, we demonstrate that minute amounts of strain in thin semiconductor epilayers can be measured using electronic Raman scattering. We applied this strain measurement technique to two different semiconductor alloy systems using coherently strained epitaxial thin films specifically designed to produce lattice-mismatch strains as small as 10(-4). Comparing our strain sensitivity and signal strength in Al(x)Ga(1-x)As with those obtained using the industry-standard technique of phonon Raman scattering, we found that there was a sensitivity improvement of 200-fold and a signal enhancement of 4 × 10(3), thus obviating key constraints in semiconductor strain metrology.

  9. Electronic Raman scattering as an ultra-sensitive probe of strain effects in semiconductors

    PubMed Central

    Fluegel, Brian; Mialitsin, Aleksej V.; Beaton, Daniel A.; Reno, John L.; Mascarenhas, Angelo

    2015-01-01

    Semiconductor strain engineering has become a critical feature of high-performance electronics because of the significant device performance enhancements that it enables. These improvements, which emerge from strain-induced modifications to the electronic band structure, necessitate new ultra-sensitive tools to probe the strain in semiconductors. Here, we demonstrate that minute amounts of strain in thin semiconductor epilayers can be measured using electronic Raman scattering. We applied this strain measurement technique to two different semiconductor alloy systems using coherently strained epitaxial thin films specifically designed to produce lattice-mismatch strains as small as 10−4. Comparing our strain sensitivity and signal strength in AlxGa1−xAs with those obtained using the industry-standard technique of phonon Raman scattering, we found that there was a sensitivity improvement of 200-fold and a signal enhancement of 4 × 103, thus obviating key constraints in semiconductor strain metrology. PMID:26017853

  10. Blood free-circulating DNA testing by highly sensitive methylation assay to diagnose colorectal neoplasias.

    PubMed

    Suehiro, Yutaka; Hashimoto, Shinichi; Higaki, Shingo; Fujii, Ikuei; Suzuki, Chieko; Hoshida, Tomomi; Matsumoto, Toshihiko; Yamaoka, Yuko; Takami, Taro; Sakaida, Isao; Yamasaki, Takahiro

    2018-03-30

    Although methylated TWIST1 is a biomarker of colorectal neoplasia, its detection from serum samples is very difficult by conventional bisulfite-based methylation assays. Therefore, we have developed a new methylation assay that enables counting of even one copy of a methylated gene in a small DNA sample amount without DNA bisulfite treatment. We performed this study to evaluate the sensitivity and specificity of serum DNA testing by the new methylation assay in combination with and without the fecal immunochemical test for hemoglobin for the detection of colorectal neoplasia. This study comprised 113 patients with colorectal neoplasia and 25 control individuals. For the new methylation assay, DNA was treated in two stages with methylation-sensitive restriction enzymes, followed by measurement of copy numbers of hTERT and methylated TWIST1 by multiplex droplet digital PCR. The fecal immunochemical test had a sensitivity of 8.0% for non-advanced adenoma, 24.3% for advanced adenoma, and 44.4% for colorectal cancer, and a specificity of 88.0%. The new assay had a sensitivity of 36.0% for non-advanced adenoma, 30.0% for advanced adenoma, and 44.4% for colorectal cancer, and a specificity of 92.0%. Combination of the both tests increased the sensitivity to 40.0%, 45.7%, and 72.2% for the detection of non-advanced adenoma, advanced adenoma, and colorectal cancer, respectively, and resulted in a specificity of 84.0%. Combination of both tests may provide an alternative screening strategy for colorectal neoplasia including potentially precancerous lesions and colorectal cancer.

  11. Early spatiotemporal-specific changes in intermediate signals are predictive of cytotoxic sensitivity to TNFα and co-treatments

    NASA Astrophysics Data System (ADS)

    Loo, Lit-Hsin; Bougen-Zhukov, Nicola Michelle; Tan, Wei-Ling Cecilia

    2017-03-01

    Signaling pathways can generate different cellular responses to the same cytotoxic agents. Current quantitative models for predicting these differential responses are usually based on large numbers of intracellular gene products or signals at different levels of signaling cascades. Here, we report a study to predict cellular sensitivity to tumor necrosis factor alpha (TNFα) using high-throughput cellular imaging and machine-learning methods. We measured and compared 1170 protein phosphorylation events in a panel of human lung cancer cell lines based on different signals, subcellular regions, and time points within one hour of TNFα treatment. We found that two spatiotemporal-specific changes in an intermediate signaling protein, p90 ribosomal S6 kinase (RSK), are sufficient to predict the TNFα sensitivity of these cell lines. Our models could also predict the combined effects of TNFα and other kinase inhibitors, many of which are not known to target RSK directly. Therefore, early spatiotemporal-specific changes in intermediate signals are sufficient to represent the complex cellular responses to these perturbations. Our study provides a general framework for the development of rapid, signaling-based cytotoxicity screens that may be used to predict cellular sensitivity to a cytotoxic agent, or identify co-treatments that may sensitize or desensitize cells to the agent.

  12. Early spatiotemporal-specific changes in intermediate signals are predictive of cytotoxic sensitivity to TNFα and co-treatments

    PubMed Central

    Loo, Lit-Hsin; Bougen-Zhukov, Nicola Michelle; Tan, Wei-Ling Cecilia

    2017-01-01

    Signaling pathways can generate different cellular responses to the same cytotoxic agents. Current quantitative models for predicting these differential responses are usually based on large numbers of intracellular gene products or signals at different levels of signaling cascades. Here, we report a study to predict cellular sensitivity to tumor necrosis factor alpha (TNFα) using high-throughput cellular imaging and machine-learning methods. We measured and compared 1170 protein phosphorylation events in a panel of human lung cancer cell lines based on different signals, subcellular regions, and time points within one hour of TNFα treatment. We found that two spatiotemporal-specific changes in an intermediate signaling protein, p90 ribosomal S6 kinase (RSK), are sufficient to predict the TNFα sensitivity of these cell lines. Our models could also predict the combined effects of TNFα and other kinase inhibitors, many of which are not known to target RSK directly. Therefore, early spatiotemporal-specific changes in intermediate signals are sufficient to represent the complex cellular responses to these perturbations. Our study provides a general framework for the development of rapid, signaling-based cytotoxicity screens that may be used to predict cellular sensitivity to a cytotoxic agent, or identify co-treatments that may sensitize or desensitize cells to the agent. PMID:28272488

  13. An improved method for detecting circulating microRNAs with S-Poly(T) Plus real-time PCR

    PubMed Central

    Niu, Yanqin; Zhang, Limin; Qiu, Huiling; Wu, Yike; Wang, Zhiwei; Zai, Yujia; Liu, Lin; Qu, Junle; Kang, Kang; Gou, Deming

    2015-01-01

    We herein describe a simple, sensitive and specific method for analysis of circulating microRNAs (miRNA), termed S-Poly(T) Plus real-time PCR assay. This new method is based on our previously developed S-Poly(T) method, in which a unique S-Poly(T) primer is used during reverse-transcription to increase sensitivity and specificity. Further increased sensitivity and simplicity of S-Poly(T) Plus, in comparison with the S-Poly(T) method, were achieved by a single-step, multiple-stage reaction, where RNAs were polyadenylated and reverse-transcribed at the same time. The sensitivity of circulating miRNA detection was further improved by a modified method of total RNA isolation from serum/plasma, S/P miRsol, in which glycogen was used to increase the RNA yield. We validated our methods by quantifying miRNA expression profiles in the sera of the patients with pulmonary arterial hypertension associated with congenital heart disease. In conclusion, we developed a simple, sensitive, and specific method for detecting circulating miRNAs that allows the measurement of 266 miRNAs from 100 μl of serum or plasma. This method presents a promising tool for basic miRNA research and clinical diagnosis of human diseases based on miRNA biomarkers. PMID:26459910

  14. Mind the Gap: Two Dissociable Mechanisms of Temporal Processing in the Auditory System

    PubMed Central

    Anderson, Lucy A.

    2016-01-01

    High temporal acuity of auditory processing underlies perception of speech and other rapidly varying sounds. A common measure of auditory temporal acuity in humans is the threshold for detection of brief gaps in noise. Gap-detection deficits, observed in developmental disorders, are considered evidence for “sluggish” auditory processing. Here we show, in a mouse model of gap-detection deficits, that auditory brain sensitivity to brief gaps in noise can be impaired even without a general loss of central auditory temporal acuity. Extracellular recordings in three different subdivisions of the auditory thalamus in anesthetized mice revealed a stimulus-specific, subdivision-specific deficit in thalamic sensitivity to brief gaps in noise in experimental animals relative to controls. Neural responses to brief gaps in noise were reduced, but responses to other rapidly changing stimuli unaffected, in lemniscal and nonlemniscal (but not polysensory) subdivisions of the medial geniculate body. Through experiments and modeling, we demonstrate that the observed deficits in thalamic sensitivity to brief gaps in noise arise from reduced neural population activity following noise offsets, but not onsets. These results reveal dissociable sound-onset-sensitive and sound-offset-sensitive channels underlying auditory temporal processing, and suggest that gap-detection deficits can arise from specific impairment of the sound-offset-sensitive channel. SIGNIFICANCE STATEMENT The experimental and modeling results reported here suggest a new hypothesis regarding the mechanisms of temporal processing in the auditory system. Using a mouse model of auditory temporal processing deficits, we demonstrate the existence of specific abnormalities in auditory thalamic activity following sound offsets, but not sound onsets. These results reveal dissociable sound-onset-sensitive and sound-offset-sensitive mechanisms underlying auditory processing of temporally varying sounds. Furthermore, the findings suggest that auditory temporal processing deficits, such as impairments in gap-in-noise detection, could arise from reduced brain sensitivity to sound offsets alone. PMID:26865621

  15. SU-F-303-05: DCE-MRI Before and During Treatment for Prediction of Concurrent Chemotherapy and Radiation Therapy Response in Head and Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Y; Diwanji, T; Zhang, B

    2015-06-15

    Purpose: To determine the ability of pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE- MRI) acquired before and during concurrent chemotherapy and radiation therapy to predict clinical response in patients with head and neck cancer. Methods: Eleven patients underwent a DCE-MRI scan at three time points: 1–2 weeks before treatment, 4–5 weeks after treatment initiation, and 3–4 months after treatment completion. Post-processing of MRI data included correction to reduce motion artifacts. The arterial input function was obtained by measuring the dynamic tracer concentration in the jugular veins. The volume transfer constant (Ktrans), extracellular extravascular volume fraction (ve), rate constant (Kep;more » Kep = Ktrans/ve), and plasma volume fraction (vp) were computed for primary tumors and cervical nodal masses. Patients were categorized into two groups based on response to therapy at 3–4 months: responders (no evidence of disease) and partial responders (regression of disease). Responses of the primary tumor and nodes were evaluated separately. A linear classifier and receiver operating characteristic curve analyses were used to determine the best model for discrimination of responders from partial responders. Results: When the above pharmacokinetic parameters of the primary tumor measured before and during treatment were incorporated into the linear classifier, a discriminative accuracy of 88.9%, with sensitivity =100% and specificity = 66.7%, was observed between responders (n=6) and partial responders (n=3) for the primary tumor with the corresponding accuracy = 44.4%, sensitivity = 66.7%, and specificity of 0% for nodal masses. When only pre-treatment parameters were used, the accuracy decreased to 66.7%, with sensitivity = 66.7% and specificity = 66.7% for the primary tumor and decreased to 33.3%, sensitivity of 50%, and specificity of 0% for nodal masses. Conclusion: Higher accuracy, sensitivity, and specificity were obtained using DCE-MRI-derived pharmacokinetic parameters acquired before and during treatment as compared with those derived from the pre-treatment time-point, exclusively.« less

  16. Diagnostic value of stool DNA testing for multiple markers of colorectal cancer and advanced adenoma: a meta-analysis.

    PubMed

    Yang, Hua; Xia, Bing-Qing; Jiang, Bo; Wang, Guozhen; Yang, Yi-Peng; Chen, Hao; Li, Bing-Sheng; Xu, An-Gao; Huang, Yun-Bo; Wang, Xin-Ying

    2013-08-01

    The diagnostic value of stool DNA (sDNA) testing for colorectal neoplasms remains controversial. To compensate for the lack of large-scale unbiased population studies, a meta-analysis was performed to evaluate the diagnostic value of sDNA testing for multiple markers of colorectal cancer (CRC) and advanced adenoma. The PubMed, Science Direct, Biosis Review, Cochrane Library and Embase databases were systematically searched in January 2012 without time restriction. Meta-analysis was performed using a random-effects model using sensitivity, specificity, diagnostic OR (DOR), summary ROC curves, area under the curve (AUC), and 95% CIs as effect measures. Heterogeneity was measured using the χ(2) test and Q statistic; subgroup analysis was also conducted. A total of 20 studies comprising 5876 individuals were eligible. There was no heterogeneity for CRC, but adenoma and advanced adenoma harboured considerable heterogeneity influenced by risk classification and various detection markers. Stratification analysis according to risk classification showed that multiple markers had a high DOR for the high-risk subgroups of both CRC (sensitivity 0.759 [95% CI 0.711 to 0.804]; specificity 0.883 [95% CI 0.846 to 0.913]; AUC 0.906) and advanced adenoma (sensitivity 0.683 [95% CI 0.584 to 0.771]; specificity 0.918 [95% CI 0.866 to 0.954]; AUC 0.946) but not for the average-risk subgroups of either. In the methylation subgroup, sDNA testing had significantly higher DOR for CRC (sensitivity 0.753 [95% CI 0.685 to 0.812]; specificity 0.913 [95% CI 0.860 to 0.950]; AUC 0.918) and advanced adenoma (sensitivity 0.623 [95% CI 0.527 to 0.712]; specificity 0.926 [95% CI 0.882 to 0.958]; AUC 0.910) compared with the mutation subgroup. There was no significant heterogeneity among studies for subgroup analysis. sDNA testing for multiple markers had strong diagnostic significance for CRC and advanced adenoma in high-risk subjects. Methylation makers had more diagnostic value than mutation markers.

  17. High-sensitivity explosives detection using dual-excitation-wavelength resonance-Raman detector

    NASA Astrophysics Data System (ADS)

    Yellampalle, Balakishore; McCormick, William B.; Wu, Hai-Shan; Sluch, Mikhail; Martin, Robert; Ice, Robert V.; Lemoff, Brian

    2014-05-01

    A key challenge for standoff explosive sensors is to distinguish explosives, with high confidence, from a myriad of unknown background materials that may have interfering spectral peaks. To meet this challenge a sensor needs to exhibit high specificity and high sensitivity in detection at low signal-to-noise ratio levels. We had proposed a Dual-Excitation- Wavelength Resonance-Raman Detector (DEWRRED) to address this need. In our previous work, we discussed various components designed at WVHTCF for a DEWRRED sensor. In this work, we show a completely assembled laboratory prototype of a DEWRRED sensor and utilize it to detect explosives from two standoff distances. The sensor system includes two novel, compact CW deep-Ultraviolet (DUV) lasers, a compact dual-band high throughput DUV spectrometer, and a highly-sensitive detection algorithm. We choose DUV excitation because Raman intensities from explosive traces are enhanced and fluorescence and solar background are not present. The DEWRRED technique exploits the excitation wavelength dependence of Raman signal strength, arising from complex interplay of resonant enhancement, self-absorption and laser penetration depth. We show measurements from >10 explosives/pre-cursor materials at different standoff distances. The sensor showed high sensitivity in explosive detection even when the signalto- noise ratio was close to one (~1.6). We measured receiver-operating-characteristics, which show a clear benefit in using the dual-excitation-wavelength technique as compared to a single-excitation-wavelength technique. Our measurements also show improved specificity using the amplitude variation information in the dual-excitation spectra.

  18. Inferior colliculus contributions to phase encoding of stop consonants in an animal model

    PubMed Central

    Warrier, Catherine M; Abrams, Daniel A; Nicol, Trent G; Kraus, Nina

    2011-01-01

    The human auditory brainstem is known to be exquisitely sensitive to fine-grained spectro-temporal differences between speech sound contrasts, and the ability of the brainstem to discriminate between these contrasts is important for speech perception. Recent work has described a novel method for translating brainstem timing differences in response to speech contrasts into frequency-specific phase differentials. Results from this method have shown that the human brainstem response is surprisingly sensitive to phase-differences inherent to the stimuli across a wide extent of the spectrum. Here we use an animal model of the auditory brainstem to examine whether the stimulus-specific phase signatures measured in human brainstem responses represent an epiphenomenon associated with far field (i.e., scalp-recorded) measurement of neural activity, or alternatively whether these specific activity patterns are also evident in auditory nuclei that contribute to the scalp-recorded response, thereby representing a more fundamental temporal processing phenomenon. Responses in anaesthetized guinea pigs to three minimally-contrasting consonant-vowel stimuli were collected simultaneously from the cortical surface vertex and directly from central nucleus of the inferior colliculus (ICc), measuring volume conducted neural activity and multiunit, near-field activity, respectively. Guinea pig surface responses were similar to human scalp-recorded responses to identical stimuli in gross morphology as well as phase characteristics. Moreover, surface recorded potentials shared many phase characteristics with near-field ICc activity. Response phase differences were prominent during formant transition periods, reflecting spectro-temporal differences between syllables, and showed more subtle differences during the identical steady-state periods. ICc encoded stimulus distinctions over a broader frequency range, with differences apparent in the highest frequency ranges analyzed, up to 3000 Hz. Based on the similarity of phase encoding across sites, and the consistency and sensitivity of response phase measured within ICc, results suggest that a general property of the auditory system is a high degree of sensitivity to fine-grained phase information inherent to complex acoustical stimuli. Furthermore, results suggest that temporal encoding in ICc contributes to temporal features measured in speech-evoked scalp-recorded responses. PMID:21945200

  19. Parenting Supports for Early Vocabulary Development: Specific Effects of Sensitivity and Stimulation through Infancy

    PubMed Central

    Vallotton, Claire; Mastergeorge, Ann; Foster, Tricia; Decker, Kalli B.; Ayoub, Catherine

    2016-01-01

    Growing recognition of disparities in early childhood language environments prompt examination of parent-child interactions which support vocabulary. Research links parental sensitivity and cognitive stimulation to child language, but has not explicitly contrasted their effects, nor examined how effects may change over time. We examined maternal sensitivity and stimulation throughout infancy using two observational methods – ratings of parents’ interaction qualities, and coding of discrete parenting behaviors - to assess the relative importance of these qualities to child vocabulary over time, and determine whether mothers make related changes in response to children’s development. Participants were 146 infants and mothers, assessed when infants were 14, 24, and 36 months. At 14 months, sensitivity had a stronger effect on vocabulary than did stimulation, but the effect of stimulation grew throughout toddlerhood. Mothers’ cognitive stimulation grew over time, whereas sensitivity remained stable. While discrete parenting behaviors changed with child age, there was no evidence of trade-offs between sensitive and stimulating behaviors, and no evidence that sensitivity moderated the effect of stimulation on child vocabulary. Findings demonstrate specificity of timing in the link between parenting qualities and child vocabulary which could inform early parent interventions, and supports a reconceptualization of the nature and measurement of parental sensitivity. PMID:28111526

  20. Evaluation of in-house ELISA using Trypanosoma cruzi lysate and recombinant antigens for diagnosis of Chagas disease and discrimination of its clinical forms.

    PubMed

    Longhi, Silvia A; Brandariz, Silvia B; Lafon, Sonia O; Niborski, Leticia L; Luquetti, Alejandro O; Schijman, Alejandro G; Levin, Mariano J; Gómez, Karina A

    2012-08-01

    The aim of this work was to investigate the potential usefulness of Trypanosoma cruzi lysate, recombinant protein JL7, and peptides P013, R13, JL18, JL19, and P0β as serological markers for human Chagas disease. We analyzed 228 sera from Brazilian Chagas disease patients classified into four clinical groups and 108 from non-chagasic patients. We defined the diagnostic sensitivity, specificity, and Kappa index measured by enzyme-linked immunosorbent assay (ELISA). As previously described, the highest values of diagnostic parameters were achieved for T. cruzi lysate and JL7; peptide P013 showed high specificity but low sensitivity. The other peptides resulted in lower sensitivity and specificity in our ELISA than T. cruzi lysate and JL7 protein. Antibodies against JL7 protein were mainly detected in sera from patients with severe chagasic cardiomyopathy, compared with those from the indeterminate form, whereas peptides failed to discriminate between the clinical forms of the disease.

  1. [Validation of the abbreviated Zarit scales for measuring burden syndrome in the primary caregiver of an elderly patient].

    PubMed

    Vélez Lopera, Johana María; Berbesí Fernández, Dedsy; Cardona Arango, Doris; Segura Cardona, Angela; Ordóñez Molina, Jaime

    2012-07-01

    To determine which abbreviated Zarit Scale (ZS) better evaluates the burden of the caregiver of an elderly patient in Medellin, Colombia. Validation study. Primary Care setting in the city of Medellin. Primary caregiver of dependent elderly patients over 65 years old. Sensitivity, specificity, positive predictive value, and negative predictive value for the different abbreviated Zarit scales, plus performing a reliability analysis using the Cronbach Alpha coefficient. The abbreviated scales obtained a sensitivity of between 36.84 and 81.58%, specificity between 95.99 and 100%, positive predictive values between 71.05 and 100%, and negative predictive values of between 91.64 and 97.42%. The scale that better determined caregiver burden in Primary Care was the Bedard Screening scale, with a sensitivity of 81.58%, a specificity of 96.35% and positive and negative predictive values of 75.61% and 97.42%, respectively. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  2. Chronic pesticide poisoning from persistent low-dose exposures in Ecuadorean floriculture workers: toward validating a low-cost test battery.

    PubMed

    Breilh, Jaime; Pagliccia, Nino; Yassi, Annalee

    2012-01-01

    Chronic pesticide poisoning is difficult to detect. We sought to develop a low-cost test battery for settings such as Ecuador's floriculture industry. First we had to develop a case definition; as with all occupational diseases a case had to have both sufficient effective dose and associated health effects. For the former, using canonical discriminant analysis, we found that adding measures of protection and overall environmental stressors to occupational category and duration of exposure was useful. For the latter, factor analysis suggested three distinct manifestations of pesticide poisoning. We then determined sensitivity and specificity of various combinations of symptoms and simple neurotoxicity tests from the Pentox questionnaire, and found that doing so increased sensitivity and specificity compared to use of acethylcholinesterase alone--the current screening standard. While sensitivity and specificity varied with different case definitions, our results support the development of a low-cost test battery for screening in such settings.

  3. Identifying Moderators of the Link Between Parent and Child Anxiety Sensitivity: The Roles of Gender, Positive Parenting, and Corporal Punishment.

    PubMed

    Graham, Rebecca A; Weems, Carl F

    2015-07-01

    A substantial body of literature suggests that anxiety sensitivity is a risk factor for the development of anxiety problems and research has now begun to examine the links between parenting, parent anxiety sensitivity and their child's anxiety sensitivity. However, the extant literature has provided mixed findings as to whether parent anxiety sensitivity is associated with child anxiety sensitivity, with some evidence suggesting that other factors may influence the association. Theoretically, specific parenting behaviors may be important to the development of child anxiety sensitivity and also in understanding the association between parent and child anxiety sensitivity. In this study, 191 families (n = 255 children and adolescents aged 6-17 and their parents) completed measures of child anxiety sensitivity (CASI) and parenting (APQ-C), and parents completed measures of their own anxiety sensitivity (ASI) and their parenting (APQ-P). Corporal punishment was associated with child anxiety sensitivity and the child's report of their parent's positive parenting behaviors moderated the association between parent and child anxiety sensitivity. The child's gender was also found to moderate the association between parent and child anxiety sensitivity, such that there was a positive association between girls' and their parents anxiety sensitivity and a negative association in boys. The findings advance the understanding of child anxiety sensitivity by establishing a link with corporal punishment and by showing that the association between parent and child anxiety sensitivity may depend upon the parenting context and child's gender.

  4. Early-life cockroach allergen and polycyclic aromatic hydrocarbon exposures predict cockroach sensitization among inner-city children

    PubMed Central

    Perzanowski, Matthew S.; Chew, Ginger L.; Divjan, Adnan; Jung, Kyung Hwa; Ridder, Robert; Tang, Deliang; Diaz, Diurka; Goldstein, Inge F.; Kinney, Patrick L.; Rundle, Andrew G.; Camann, David E.; Perera, Frederica P.; Miller, Rachel L.

    2013-01-01

    Background Sensitization to cockroach is one of the strongest identified risk factors for greater asthma morbidity in low-income, urban communities; however, the timing of exposures relevant to development of sensitization has not been elucidated fully. Further, exposure to combustion byproducts, including polycyclic aromatic hydrocarbons (PAHs), may augment the development of allergic sensitization. Objective To test the hypotheses that domestic cockroach allergen measured prenatally would predict cockroach sensitization in early childhood, and that this association would be greater for children exposed to higher concentrations of PAHs. Methods Dominican and African-American pregnant women living in NYC were enrolled. In the third trimester, expectant mothers wore personal air samplers for measurement of 8 nonvolatile PAHs and the semi-volatile PAH pyrene, and dust was collected from homes for allergen measurement. Glutathione-s-transferase mu (GSTM1) gene polymorphisms were measured in children. Allergen-specific IgE was measured from the children at ages 2, 3, 5 and 7 years. Results Bla g2 in prenatal kitchen dust predicted cockroach sensitization at age 5–7 years [adjusted relative risk (RR) 1.15; P = 0.001; n = 349]. The association was observed only among children above [RR 1.22; P = 0.001], but not below [RR 1.07; P = 0.24] median sum of 8 nonvolatile PAH levels. The association was most pronounced among children with higher PAH and null in the GSTM1 gene [RR 1.54; P = 0.001]. Conclusions Prenatal exposure to cockroach allergen was associated with a greater risk of developing allergic sensitization. This risk was increased by exposure to nonvolatile PAHs, with children null for the GSTM1 mutation particularly vulnerable. Key messages Domestic exposure to cockroach allergen measured prenatally predicted sensitization to cockroach at age 5–7 years. Cockroach allergen predicted sensitization only among children also exposed to higher levels of airborne non-volatile polycyclic aromatic hydrocarbons, indicating that these combustion byproducts may act as adjuvants in the development of cockroach sensitization in urban environments. These findings suggest that targeting either allergen or combustion sources with primary prevention could be successful in reducing the development of cockroach sensitization. PMID:23391330

  5. Depth-sensitive optical spectroscopy for layered tissue measurements (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Yu, Xiaojun; Liu, Quan; Liu, Linbo; Ong, Yi Hong

    2017-02-01

    Disease diagnosis based on the visual inspection of the pathological presentations or symptoms on the epithelial tissue such as the skin are subjective and highly depend on the experience of the doctors. Vital diagnostic information for the accurate identification of diseases is usually located underneath the surface and its depth distribution is known to be related to disease progression. Although optical spectroscopic measurements are fast and non-invasive, the accurate retrieval of the depth-specific diagnostic information is complicated by the heterogeneous nature of epithelial tissues. The optical signal measured from a tissue is often the result of averaging from a large tissue volume that mixes information from the region of interest and the surrounding tissue region, especially from the overlaying layers. Our group has developed a series of techniques for depth sensitive optical measurements from such layered tissues. We will first review the earlier development of composite fiber-optic probe, in which the source-detector separation and the angles of source and detector fibers are varied to achieve depth sensitive measurements. Then the more recent development of non-contact axicon lens based probes for depth sensitive fluorescence measurements and the corresponding numerical methods for optimization will be introduced. Finally, the most recently developed snapshot axicon lens based probe that can measure Raman spectra from five different depths at the same time will be discussed. Results from tissue phantoms, ex vivo pork samples and in vivo fingernail measurements will be presented, which indicates the great potential of depth sensitive optical spectroscopy for clinical tissue diagnosis.

  6. Comparison of (1->3)-β-D-glucan, mannan/anti-mannan antibodies, and Cand-Tec Candida antigen as serum biomarkers for candidemia.

    PubMed

    Held, Jürgen; Kohlberger, Isabelle; Rappold, Elfriede; Busse Grawitz, Andrea; Häcker, Georg

    2013-04-01

    We conducted a case-control study using the Fungitell assay, the novel Platelia Candida Antigen (Ag) Plus and Candida Antibody (Ab) Plus assays, and the Cand-Tec latex agglutination test to evaluate the usefulness of (1→3)-β-D-glucan (BDG), mannan antigen with/without anti-mannan antibody, and Cand-Tec Candida antigen measurement for the diagnosis of candidemia. A total of 56 patients fulfilled the inclusion criteria and were enrolled. One hundred patients with bacteremia and 100 patients with sterile blood cultures served as negative controls. In the candidemia group, median (1→3)-β-D-glucan, mannan antigen, and anti-mannan antibody levels were 427 pg/ml, 190 pg/ml, and 18.6 antibody units (AU)/ml, respectively. All three parameters were significantly elevated in patients with candidemia. The sensitivity and specificity were, respectively, 87.5% and 85.5% for (1→3)-β-D-glucan, 58.9% and 97.5% for mannan antigen, 62.5% and 65.0% for anti-mannan antibody, 89.3% and 63.0% for mannan antigen plus anti-mannan antibody, 89.3% and 85.0% for BDG plus mannan antigen, and 13.0% and 93.9% for Cand-Tec Candida antigen. The low mannan antigen sensitivity was in part caused by Candida parapsilosis and Candida guilliermondii fungemias, which were not detected by the Platelia Candida Ag Plus assay. When the cutoff was lowered from 125 pg/ml to 50 pg/ml, mannan antigen sensitivity increased to 69.6% without severely affecting the specificity (93.5%). Contrary to recently published data, superficial candidiasis was not associated with elevated mannan antigen levels, not even after the cutoff was lowered. Combining procalcitonin (PCT) with (1→3)-β-D-glucan to increase specificity provided a limited advantage because the benefit of the combination did not outweigh the loss of sensitivity. Our results demonstrate that the Cand-Tec Candida antigen and the mannan antigen plus anti-mannan antibody measurements have unacceptably low sensitivity or specificity. Of the four tests compared, (1→3)-β-D-glucan and mannan antigen are the superior biomarkers, depending on whether a sensitivity-driven or specificity-driven approach is used.

  7. Comparison of (1→3)-β-d-Glucan, Mannan/Anti-Mannan Antibodies, and Cand-Tec Candida Antigen as Serum Biomarkers for Candidemia

    PubMed Central

    Kohlberger, Isabelle; Rappold, Elfriede; Busse Grawitz, Andrea; Häcker, Georg

    2013-01-01

    We conducted a case-control study using the Fungitell assay, the novel Platelia Candida Antigen (Ag) Plus and Candida Antibody (Ab) Plus assays, and the Cand-Tec latex agglutination test to evaluate the usefulness of (1→3)-β-d-glucan (BDG), mannan antigen with/without anti-mannan antibody, and Cand-Tec Candida antigen measurement for the diagnosis of candidemia. A total of 56 patients fulfilled the inclusion criteria and were enrolled. One hundred patients with bacteremia and 100 patients with sterile blood cultures served as negative controls. In the candidemia group, median (1→3)-β-d-glucan, mannan antigen, and anti-mannan antibody levels were 427 pg/ml, 190 pg/ml, and 18.6 antibody units (AU)/ml, respectively. All three parameters were significantly elevated in patients with candidemia. The sensitivity and specificity were, respectively, 87.5% and 85.5% for (1→3)-β-d-glucan, 58.9% and 97.5% for mannan antigen, 62.5% and 65.0% for anti-mannan antibody, 89.3% and 63.0% for mannan antigen plus anti-mannan antibody, 89.3% and 85.0% for BDG plus mannan antigen, and 13.0% and 93.9% for Cand-Tec Candida antigen. The low mannan antigen sensitivity was in part caused by Candida parapsilosis and Candida guilliermondii fungemias, which were not detected by the Platelia Candida Ag Plus assay. When the cutoff was lowered from 125 pg/ml to 50 pg/ml, mannan antigen sensitivity increased to 69.6% without severely affecting the specificity (93.5%). Contrary to recently published data, superficial candidiasis was not associated with elevated mannan antigen levels, not even after the cutoff was lowered. Combining procalcitonin (PCT) with (1→3)-β-d-glucan to increase specificity provided a limited advantage because the benefit of the combination did not outweigh the loss of sensitivity. Our results demonstrate that the Cand-Tec Candida antigen and the mannan antigen plus anti-mannan antibody measurements have unacceptably low sensitivity or specificity. Of the four tests compared, (1→3)-β-d-glucan and mannan antigen are the superior biomarkers, depending on whether a sensitivity-driven or specificity-driven approach is used. PMID:23363830

  8. Assessment of insulin sensitivity by the hyperinsulinemic euglycemic clamp: Comparison with the spectral analysis of photoplethysmography.

    PubMed

    De Souza, Aglecio Luiz; Batista, Gisele Almeida; Alegre, Sarah Monte

    2017-01-01

    We compare spectral analysis of photoplethysmography (PTG) with insulin resistance measured by the hyperinsulinemic euglycemic clamp (HEC) technique. A total of 100 nondiabetic subjects, 43 men and 57 women aged 20-63years, 30 lean, 42 overweight and 28 obese were enrolled in the study. These patients underwent an examination with HEC, and an examination with the PTG spectral analysis and calculation of the PTG Total Power (PTG-TP). Receiver-operating characteristic (ROC) curves were constructed to determine the specificity and sensitivity of PTG-TP in the assessment of insulin resistance. There is a moderate correlation between insulin sensitivity (M-value) and PTG-TP (r=- 0.64, p<0.0001). The ROC curves showed that the most relevant cutoff to the whole study group was a PTG-TP>406.2. This cut-off had a sensitivity=95.7%, specificity =84,4% and the area under the ROC curve (AUC)=0.929 for identifying insulin resistance. All AUC ROC curve analysis were significant (p<0.0001). The use of the PTG-TP marker measured from the PTG spectral analysis is a useful tool in screening and follow up of IR, especially in large-scale studies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Prevalence of allergic sensitization in the U.S.: Results from the National Health and Nutrition Examination Survey (NHANES) 2005–2006

    PubMed Central

    Salo, Päivi M.; Arbes, Samuel J.; Jaramillo, Renee; Calatroni, Agustin; Weir, Charles H.; Sever, Michelle L.; Hoppin, Jane A.; Rose, Kathryn M.; Liu, Andrew H.; Gergen, Peter J.; Mitchell, Herman E.; Zeldin, Darryl C.

    2014-01-01

    Background Allergic sensitization is an important risk factor for the development of atopic disease. The National Health and Nutrition Examination Survey (NHANES) 2005–2006 provides the most comprehensive information on IgE-mediated sensitization in the general US population. Objective We investigated clustering, sociodemographic and regional patterns of allergic sensitization and examined risk factors associated with IgE-mediated sensitization. Methods Data for this cross-sectional analysis were obtained from NHANES 2005–2006. Participants aged ≥1 year (N=9440) were tested for sIgEs to inhalant and food allergens; participants ≥6 years were tested for 19 sIgEs, and children aged 1–5 years for 9 sIgEs. Serum samples were analyzed using the ImmunoCAP System. Information on demographics and participant characteristics was collected by questionnaire. Results Of the study population aged 6 and older, 44.6% had detectable sIgEs, while 36.2% of children aged 1–5 years were sensitized to ≥1 allergen. Allergen-specific IgEs clustered into 7 groups that might have largely reflected biological cross-reactivity. Although sensitization to individual allergens and allergen types showed regional variation, the overall prevalence of sensitization did not differ across census regions, except in early childhood. In multivariate modeling, young age, male gender, non-Hispanic black race/ethnicity, geographic location (census region), and reported pet avoidance measures were most consistently associated with IgE-mediated sensitization. Conclusions The overall prevalence of allergic sensitization does not vary across US census regions, except in early life, although allergen-specific sensitization differs by sociodemographic and regional factors. Biological cross-reactivity may be an important, but not a sole, contributor to the clustering of allergen-specific IgEs. Clinical implications IgE-mediated sensitization shows clustering patterns and differs by sociodemographic and regional factors, but the overall prevalence of sensitization may not vary across US census regions. PMID:24522093

  10. MR arthrography including abduction and external rotation images in the assessment of atraumatic multidirectional instability of the shoulder.

    PubMed

    Schaeffeler, Christoph; Waldt, Simone; Bauer, Jan S; Kirchhoff, Chlodwig; Haller, Bernhard; Schröder, Michael; Rummeny, Ernst J; Imhoff, Andreas B; Woertler, Klaus

    2014-06-01

    To evaluate diagnostic signs and measurements in the assessment of capsular redundancy in atraumatic multidirectional instability (MDI) of the shoulder on MR arthrography (MR-A) including abduction/external rotation (ABER) images. Twenty-one MR-A including ABER position of 20 patients with clinically diagnosed MDI and 17 patients without instability were assessed by three radiologists. On ABER images, presence of a layer of contrast between the humeral head (HH) and the anteroinferior glenohumeral ligament (AIGHL) (crescent sign) and a triangular-shaped space between the HH, AIGHL and glenoid (triangle sign) were evaluated; centring of the HH was measured. Anterosuperior herniation of the rotator interval (RI) capsule and glenoid version were determined on standard imaging planes. The crescent sign had a sensitivity of 57 %/62 %/48 % (observers 1/2/3) and specificity of 100 %/100 %/94 % in the diagnosis of MDI. The triangle sign had a sensitivity of 48 %/57 %/48 % and specificity of 94 %/94 %/100 %. The combination of both signs had a sensitivity of 86 %/90 %/81 % and specificity of 94 %/94 %/94 %. A positive triangle sign was significantly associated with decentring of the HH. Measurements of RI herniation, RI width and glenoid were not significantly different between both groups. Combined assessment of redundancy signs on ABER position MR-A allows for accurate differentiation between patients with atraumatic MDI and patients with clinically stable shoulders; measurements on standard imaging planes appear inappropriate. MR arthrography has the possibility to accurately identify patients with atraumatic MDI. Imaging of the shoulder in abduction and external rotation provides additive information. Capsular enlargement of the shoulder can be diagnosed on MR arthrography.

  11. The peripheral artery questionnaire: a new disease-specific health status measure for patients with peripheral arterial disease.

    PubMed

    Spertus, John; Jones, Philip; Poler, Sherri; Rocha-Singh, Krishna

    2004-02-01

    The most common indication for treating patients with peripheral arterial disease is to improve their health status: their symptoms, function, and quality of life. Quantifying health status requires a valid, reproducible, and sensitive disease-specific measure. The Peripheral Artery Questionnaire (PAQ) is a 20-item questionnaire developed to meet this need by quantifying patients' physical limitations, symptoms, social function, treatment satisfaction, and quality of life. Psychometric and clinical properties of the PAQ were evaluated in a prospective cohort study of 44 patients undergoing elective percutaneous peripheral revascularization. To establish reproducibility, 2 assessments were performed 2 weeks apart and before revascularization. The change in scores before and 6 weeks after revascularization were used to determine the instruments' responsiveness and were compared with the Short Form-36 and the Walking Impairment Questionnaire. A series of cross-sectional analyses were performed to establish the construct validity of the PAQ. The 7 domains of the PAQ were internally reliable, with Cronbach alpha = 0.80 to 0.94. The test-retest reliability analyses revealed insignificant mean changes of 0.6 to 2.3 points (P = not significant for all). Conversely, the change after revascularization ranged from 13.7 to 41.9 points (P < or =.001 for all), reflecting substantial sensitivity of the PAQ to clinical improvement. The PAQ Summary Scale was the most sensitive of all scales tested. Construct validity was established by demonstrating correlations with other measures of patient health status. The PAQ is a valid, reliable, and responsive disease-specific measure for patients with peripheral arterial disease. It may prove to be a useful end point in clinical trials and a potential aid in disease management.

  12. Coronary artery calcification and large artery stiffness in renal transplant recipients.

    PubMed

    Stróżecki, Paweł; Serafin, Zbigniew; Adamowicz, Andrzej; Flisiński, Mariusz; Włodarczyk, Zbigniew; Manitius, Jacek

    2015-09-01

    Coronary artery calcification (CAC) is an independent predictor of cardiovascular (CV) events in renal transplant recipients (RTR). Carotid-femoral pulse wave velocity (PWV), a non-invasive measure of large artery stiffness, also predicts CV events in RTR. The study investigated the relationship between CAC and PWV in RTR and assessed the performance of PWV measurement in predicting CAC. The study was performed as cross-sectional analysis in 104 RTR. CAC was determined as total calcium score (CS) and calcium mass (CM). Carotid-femoral PWV was also measured. Sensitivity, specificity and receiver operating characteristic (ROC) curve were used to assess the performance of PWV as diagnostic test for presence of CAC. CAC was found in 69% of participants. PWV was higher in RTR with CAC than in RTR without CAC (10.2±2.2 vs. 8.6±15; p<0.001). In univariate analysis CS was significantly correlated with age, duration of hypertension, waist circumference, PWV, hemoglobin concentration, and serum glucose. In multiple linear regression analysis CS was independently associated with age only, but not with PWV. Sensitivity and specificity of PWV>7.6m/s as cut-off for detecting CAC>0 was 0.889 and 0.406, respectively. Sensitivity and specificity of PWV>10.2m/s as cut-off for detecting severe CAC (CS>400) was 0.319 and 0.969, respectively. The study confirmed high prevalence of coronary artery calcification in renal transplant recipients. The study does not support the hypothesis that aortic stiffness is independently associated with coronary artery calcification in RTR. PWV measurement may be useful in excluding severe CAC in RTR. Copyright © 2015 Medical University of Bialystok. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  13. Cross-cultural adaptation and validation of the Korean version of the EQ-5D in patients with rheumatic diseases.

    PubMed

    Kim, Myoung-Hee; Cho, Young-Shin; Uhm, Wan-Sik; Kim, Sehyun; Bae, Sang-Cheol

    2005-06-01

    This study aimed to determine the cross-cultural adaptation and validation of the Korean version of the EQ-5D in rheumatic conditions. Translation, back-translation and cognitive debriefing were performed according to the EuroQol group's guidelines. For validity, 508 patients were recruited and administered the EQ-5D, Short-Form 36 and condition-specific measures. Construct validity and sensitivity were evaluated by testing a-priori hypotheses. For reliability, another 57 patients repeated the EQ-5D at 1-week interval, and intra-class correlations (ICC) and kappa statistics were estimated. For responsiveness, another 60 patients repeated it at 12-week interval within the context of clinical trial, and standardized response mean(SRM) were calculated. The cross-cultural adaptation produced no major modifications in the scale. The associations of the EQ-5D with the generic- and condition-specific measures were observed as expected in hypotheses: the higher EQ-5Dindex and EQ-5D(VAS) scores, the better health status by generic- or condition-specific measures, and the better functional class. The ICCs were 0.751 and 0.767, respectively, and kappa ranged from 0.455 to 0.772. The SRM were 0.649 and 0.410, respectively. The Korean EQ-5D exhibits good validity and sensitivity in various rheumatic conditions. Although its reliability and responsiveness were not excellent, it seems acceptable if condition-specific measures are applied together.

  14. Sensitivity, Specificity, PPV, and NPV for Predictive Biomarkers.

    PubMed

    Simon, Richard

    2015-08-01

    Molecularly targeted cancer drugs are often developed with companion diagnostics that attempt to identify which patients will have better outcome on the new drug than the control regimen. Such predictive biomarkers are playing an increasingly important role in precision oncology. For diagnostic tests, sensitivity, specificity, positive predictive value, and negative predictive are usually used as performance measures. This paper discusses these indices for predictive biomarkers, provides methods for their calculation with survival or response endpoints, and describes assumptions involved in their use. Published by Oxford University Press 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  15. Predictive Accuracy of Sweep Frequency Impedance Technology in Identifying Conductive Conditions in Newborns.

    PubMed

    Aithal, Venkatesh; Kei, Joseph; Driscoll, Carlie; Murakoshi, Michio; Wada, Hiroshi

    2018-02-01

    Diagnosing conductive conditions in newborns is challenging for both audiologists and otolaryngologists. Although high-frequency tympanometry (HFT), acoustic stapedial reflex tests, and wideband absorbance measures are useful diagnostic tools, there is performance measure variability in their detection of middle ear conditions. Additional diagnostic sensitivity and specificity measures gained through new technology such as sweep frequency impedance (SFI) measures may assist in the diagnosis of middle ear dysfunction in newborns. The purpose of this study was to determine the test performance of SFI to predict the status of the outer and middle ear in newborns against commonly used reference standards. Automated auditory brainstem response (AABR), HFT (1000 Hz), transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), and SFI tests were administered to the study sample. A total of 188 neonates (98 males and 90 females) with a mean gestational age of 39.4 weeks were included in the sample. Mean age at the time of testing was 44.4 hr. Diagnostic accuracy of SFI was assessed in terms of its ability to identify conductive conditions in neonates when compared with nine different reference standards (including four single tests [AABR, HFT, TEOAE, and DPOAE] and five test batteries [HFT + DPOAE, HFT + TEOAE, DPOAE + TEOAE, DPOAE + AABR, and TEOAE + AABR]), using receiver operating characteristic (ROC) analysis and traditional test performance measures such as sensitivity and specificity. The test performance of SFI against the test battery reference standard of HFT + DPOAE and single reference standard of HFT was high with an area under the ROC curve (AROC) of 0.87 and 0.82, respectively. Although the HFT + DPOAE test battery reference standard performed better than the HFT reference standard in predicting middle ear conductive conditions in neonates, the difference in AROC was not significant. Further analysis revealed that the highest sensitivity and specificity for SFI (86% and 88%, respectively) was obtained when compared with the reference standard of HFT + DPOAE. Among the four single reference standards, SFI had the highest sensitivity and specificity (76% and 88%, respectively) when compared against the HFT reference standard. The high test performance of SFI against the HFT and HFT + DPOAE reference standards indicates that the SFI measure has appropriate diagnostic accuracy in detection of conductive conditions in newborns. Hence, the SFI test could be used as adjunct tool to identify conductive conditions in universal newborn hearing screening programs, and can also be used in diagnostic follow-up assessments. American Academy of Audiology

  16. Sensitivity and Specificity of a Single Emergency Department Measurement of Urinary Neutrophil Gelatinase–Associated Lipocalin for Diagnosing Acute Kidney Injury

    PubMed Central

    Nickolas, Thomas L.; O’Rourke, Matthew J.; Yang, Jun; Sise, Meghan E.; Canetta, Pietro A.; Barasch, Nicholas; Buchen, Charles; Khan, Faris; Mori, Kiyoshi; Giglio, James; Devarajan, Prasad; Barasch, Jonathan

    2010-01-01

    Background A single serum creatinine measurement cannot distinguish acute kidney injury from chronic kidney disease or prerenal azotemia. Objective To test the sensitivity and specificity of a single measurement of urinary neutrophil gelatinase–associated lipocalin (NGAL) and other urinary proteins to detect acute kidney injury in a spectrum of patients. Design Prospective cohort study. Setting Emergency department of Columbia University Medical Center, New York, New York. Participants 635 patients admitted to the hospital with acute kidney injury, prerenal azotemia, chronic kidney disease, or normal kidney function. Measurements Diagnosis of acute kidney injury was based on the RIFLE (risk, injury, failure, loss, and end-stage) criteria and assigned by researchers who were blinded to experimental measurements. Urinary NGAL was measured by immunoblot, N-acetyl-β-D-glucosaminidase (NAG) by enzyme measurement, α1-microglobulin and α1-acid glycoprotein by immunonephelometry, and serum creatinine by Jaffe kinetic reaction. Experimental measurements were not available to treating physicians. Results Patients with acute kidney injury had a significantly elevated mean urinary NGAL level compared with the other kidney function groups (416 μg/g creatinine [SD, 387]; P = 0.001). At a cutoff value of 130 μg/g creatinine, sensitivity and specificity of NGAL for detecting acute injury were 0.900 (95% CI, 0.73 to 0.98) and 0.995 (CI, 0.990 to 1.00), respectively, and positive and negative likelihood ratios were 181.5 (CI, 58.33 to 564.71) and 0.10 (CI, 0.03 to 0.29); these values were superior to those for NAG, α1-microglobulin, α1-acid glycoprotein, fractional excretion of sodium, and serum creatinine. In multiple logistic regression, urinary NGAL level was highly predictive of clinical outcomes, including nephrology consultation, dialysis, and admission to the intensive care unit (odds ratio, 24.71 [CI, 7.69 to 79.42]). Limitations All patients came from a single center. Few kidney biopsies were performed. Conclusion A single measurement of urinary NGAL helps to distinguish acute injury from normal function, prerenal azotemia, and chronic kidney disease and predicts poor inpatient outcomes. PMID:18519927

  17. Measurement of urinary metanephrines to screen for pheochromocytoma in an unselected hospital referral population

    PubMed Central

    Brain, Keith L.; Kay, Jonathan; Shine, Brian

    2009-01-01

    Background Despite the rarity of pheochromocytoma, the dangers of uncontrolled severe hypertension and the very effective surgical treatment of this condition mean that diagnosis is important. Urinary or plasma catecholamines or catecholamine-derivatives are commonly used to screen for pheochromocytomas prior to imaging. This study investigates whether derived measures obtained from 24-hour urinary metanephrine results, patient age and sex can better predict tumors in populations with a low pre-test probability. Methods This study takes a pragmatic approach by retrospectively studying the outcomes of an unselected population referred for urinary metanephrine testing (1819 patients) to a tertiary hospital laboratory, and investigates the usefulness of some simple derivative measures for detecting pheochromocytoma. Urinary 24-hour excretion of metanephrine, normetanephrine and 3-methoxytyramine were normalized by dividing by an age- and sex- specific reference range. The ability of products of these normalized measures to predict pheochromocytomas was assessed, compared to a gold standard of biopsy-confirmed tumor. Results The normalized product of urinary metanephrine and normetanephrine excretion (nMAD.nNMT) proved to be a highly sensitive (100%) and specific (99.1%) measure yielding a positive predictive value 82%. Receiver-operator characteristic curves were not improved by including the normalized 3-methoxytyramine concentrations in the product. nMAD.nNMT gave higher sensitivity and specificity than either test alone. Conclusion We suggest that nMAD.nNMT is a useful measure for identifying pheochromocytoma in a population with a low pre-test probability. PMID:16990424

  18. The Role of Condition-Specific Preference-Based Measures in Health Technology Assessment.

    PubMed

    Rowen, Donna; Brazier, John; Ara, Roberta; Azzabi Zouraq, Ismail

    2017-12-01

    A condition-specific preference-based measure (CSPBM) is a measure of health-related quality of life (HRQOL) that is specific to a certain condition or disease and that can be used to obtain the quality adjustment weight of the quality-adjusted life-year (QALY) for use in economic models. This article provides an overview of the role and the development of CSPBMs, and presents a description of existing CSPBMs in the literature. The article also provides an overview of the psychometric properties of CSPBMs in comparison with generic preference-based measures (generic PBMs), and considers the advantages and disadvantages of CSPBMs in comparison with generic PBMs. CSPBMs typically include dimensions that are important for that condition but may not be important across all patient groups. There are a large number of CSPBMs across a wide range of conditions, and these vary from covering a wide range of dimensions to more symptomatic or uni-dimensional measures. Psychometric evidence is limited but suggests that CSPBMs offer an advantage in more accurate measurement of milder health states. The mean change and standard deviation can differ for CSPBMs and generic PBMs, and this may impact on incremental cost-effectiveness ratios. CSPBMs have a useful role in HTA where a generic PBM is not appropriate, sensitive or responsive. However, due to issues of comparability across different patient groups and interventions, their usage in health technology assessment is often limited to conditions where it is inappropriate to use a generic PBM or sensitivity analyses.

  19. [Comparison of different methods of temperature measurment in children].

    PubMed

    Pavlović, Momcilo; Radlović, Nedeljko; Leković, Zoran; Berenji, Karolina

    2008-01-01

    The consequences of failing to notice fever in children can be serious. On the other hand, false positive reading can result in unnecesery investigation or diagnostic approach. The aim of this study was to compare different ways of body temperature measurement. This prospective study was carried out on Pediatric Department of General Hospital in Subotica during 10 months (March-December 2006). In 263 children aged 1 month to 18 years of age, the body temperature was obtained from 4 measurement sites: tactile assesment, forehead and ear by electronic thermometer, rectal temperature in small children (up to 2 years of age) or axillar temperature in older children by mercury thermometer. Tympanic thermometry was considered as a standard for fever detection. The sensitivity of rectal temperature to detect fever is 46.67%, while specificity is 92.19%. The sensitivity of fever detection by electronic thermometry on the forehead is lower according to rectal thermometry - 36.08%, while specificity is 95.18%. The lowest values ofsensitivity are recorded in axillar thermometry (35.82%), specificity is 90.20%. The correlation coefficient is higher between tympanic and rectal temperature measurement (r=0.5076, p<0.0005), than between tympanic and forehead measurements (r=0.5076, p<0,0005), while the lowest was between tympanic and axillar mesurement sites (r=0.4933, p<0.0005). The results of our study and literature data show that the most accurate methods of thermometry are rectal measurement of body temperature in small children and tympanic thermometry in children over 2 years of age.

  20. The computerized adaptive diagnostic test for major depressive disorder (CAD-MDD): a screening tool for depression.

    PubMed

    Gibbons, Robert D; Hooker, Giles; Finkelman, Matthew D; Weiss, David J; Pilkonis, Paul A; Frank, Ellen; Moore, Tara; Kupfer, David J

    2013-07-01

    To develop a computerized adaptive diagnostic screening tool for depression that decreases patient and clinician burden and increases sensitivity and specificity for clinician-based DSM-IV diagnosis of major depressive disorder (MDD). 656 individuals with and without minor and major depression were recruited from a psychiatric clinic and a community mental health center and through public announcements (controls without depression). The focus of the study was the development of the Computerized Adaptive Diagnostic Test for Major Depressive Disorder (CAD-MDD) diagnostic screening tool based on a decision-theoretical approach (random forests and decision trees). The item bank consisted of 88 depression scale items drawn from 73 depression measures. Sensitivity and specificity for predicting clinician-based Structured Clinical Interview for DSM-IV Axis I Disorders diagnoses of MDD were the primary outcomes. Diagnostic screening accuracy was then compared to that of the Patient Health Questionnaire-9 (PHQ-9). An average of 4 items per participant was required (maximum of 6 items). Overall sensitivity and specificity were 0.95 and 0.87, respectively. For the PHQ-9, sensitivity was 0.70 and specificity was 0.91. High sensitivity and reasonable specificity for a clinician-based DSM-IV diagnosis of depression can be obtained using an average of 4 adaptively administered self-report items in less than 1 minute. Relative to the currently used PHQ-9, the CAD-MDD dramatically increased sensitivity while maintaining similar specificity. As such, the CAD-MDD will identify more true positives (lower false-negative rate) than the PHQ-9 using half the number of items. Inexpensive (relative to clinical assessment), efficient, and accurate screening of depression in the settings of primary care, psychiatric epidemiology, molecular genetics, and global health are all direct applications of the current system. © Copyright 2013 Physicians Postgraduate Press, Inc.

  1. Diagnostic utility of attenuation measurement (Hounsfield units) in computed tomography stonogram in predicting the radio-opacity of urinary calculi in plain abdominal radiographs.

    PubMed

    Chua, Michael E; Gatchalian, Glenn T; Corsino, Michael Vincent; Reyes, Buenaventura B

    2012-10-01

    (1) To determine the best cut-off level of Hounsfield units (HU) in the CT stonogram that would predict the appearance of a urinary calculi in plain KUB X-ray; (2) to estimate the sensitivity and specificity of the best cut-off HU; and (3) to determine whether stone size and location affect the in vivo predictability. A prospective cross-sectional study of patients aged 18-85 diagnosed with urolithiases on CT stonogram with concurrent plain KUB radiograph was conducted. Appearance of stones was recorded, and significant difference between radiolucent and radio-opaque CT attenuation level was determined using ANOVA. Receiver operating characteristics (ROC) curve determined the best HU cut-off value. Stone size and location were used for factor variability analysis. A total of 184 cases were included in this study, and the average urolithiasis size on CT stonogram was 0.84 cm (0.3-4.9 cm). On KUB X-ray, 34.2 % of the urolithiases were radiolucent and 65.8 % were radio-opaque. Mean value of CT Hounsfield unit for radiolucent stones was 358.25 (±156), and that for radio-opaque stones was 816.51 (±274). ROC curve determined the best cut-off value of HU at 498.5, with the sensitivity of 89.3 % and specificity of 87.3 %. For >4 mm stones, the sensitivity was 91.3 % and the specificity was 81.8 %. On the other hand, for =<4 mm stones, the sensitivity was 60 % and the specificity was 89.5 %. Based on the constructed ROC curve, a threshold value of 498.5 HU in CT stonogram was established as cut-off in determining whether a calculus is radio-opaque or radiolucent. The determined overall sensitivity and specificity of the set cut-off HU value are optimal. Stone size but not location affects the sensitivity and specificity.

  2. The cut-off values of anthropometric variables for predicting mild cognitive impairment in Malaysian older adults: a large population based cross-sectional study

    PubMed Central

    Won, Huiloo; Abdul, Manaf Zahara; Mat Ludin, Arimi Fitri; Omar, Mohd Azahadi; Razali, Rosdinom; Shahar, Suzana

    2017-01-01

    Purpose Older adults are at risk of mild cognitive impairment (MCI), and simple anthropometric measurements can be used to screen for this condition. Thus, the aim of this study was to explore the cut-off values of body mass index (BMI) and waist circumference (WC) for predicting the risk of MCI in older Malaysian adults. Methods A total of 2,240 Malaysian older adults aged ≥60 years were recruited using multistage random sampling in a population based cross-sectional study. Receiver operating characteristic (ROC) curve was used to determine the cut-off values of BMI and WC with optimum sensitivity and specificity for the detection of MCI. Age, gender, years of education, smoking habit, alcohol consumption, depression, and medical conditions were used as confounding factors in this analysis. Results A BMI cut-off value of 26 kg/m2 (area under the receiver operating characteristic curve [AUC] 0.725; sensitivity 90.5%; specificity 38.8%) was appropriate in identifying the risk of getting MCI in both men and women. The optimum WC cut-offs for likelihood of MCI were 90 cm (AUC 0.745; sensitivity 78.0%; specificity 59.8%) for men and 82 cm (AUC 0.714; sensitivity 84.3%; specificity 49.7%) for women. The optimum calf circumference (CC) cut-off values for identifying MCI were 29 cm (AUC 0.731; sensitivity 72.6%; specificity 61.1%) for men and 26 cm (AUC 0.598; sensitivity 79.1%; specificity 45.3%) for women. Conclusion The cut-off values could be advocated and used as part of the screening of MCI among older Malaysian adults. There is a need to further determine the predictive values of these cut-off points on outcomes through longitudinal study design. PMID:28223785

  3. Mitral valve resistance determines hemodynamic consequences of severe rheumatic mitral stenosis and immediate outcomes of percutaneous valvuloplasty.

    PubMed

    Sanati, Hamidreza; Zolfaghari, Reza; Samiei, Niloufar; Rezaei, Yousef; Chitsazan, Mitra; Zahedmehr, Ali; Shakerian, Farshad; Kiani, Reza; Firouzi, Ata; Rezaei Tabrizi, Reza

    2017-02-01

    The mitral valve area (MVA) poorly reflects the hemodynamic status of (MS). In this study, we compared the MVA with mitral valve resistance (MVR) with regard to the determination of hemodynamic consequences of MS and the immediate outcomes of percutaneous balloon mitral valvuloplasty (PBMV). In a prospective study, 36 patients with severe rheumatic MS with left ventricular ejection fraction (LVEF) >50% were evaluated. They underwent transthoracic echocardiography (TTE) and catheterization. The MVA was measured by two-dimensional planimetry and pressure half-time (PHT), and the MVR was calculated using the equation: 1333 × transmitral pressure gradient mean transmitral diastolic flow rate. The patients' mean age was 47.8±10.5 years. MVR ≥140.6 dynes·s/cm 5 detected systolic pulmonary arterial pressure (sPAP) >55 mm Hg with a sensitivity of 100% and a specificity of 74%. The sensitivity and specificity of MVA<0.75 cm 2 to discriminate elevated sPAP were 81% and 89%, respectively. PHT ≥323.5 mseconds had a sensitivity of 78% and a specificity of 96% to detect an elevated sPAP. To predict a successful PBMV, preprocedural MVR ≥106.1 dynes·s/cm 5 had a sensitivity of 100% and a specificity of 67% (area under the curve [AUC]=0.763; 95% confidence interval [CI]=0.520-1.006; P=.034); preprocedural MVA <0.95 cm 2 had a sensitivity of 78% and a specificity of 73% (AUC=0.730; 95% CI=0.503-0.956; P=.065); and preprocedural PHT ≥210.5 mseconds had a sensitivity of 73% and a specificity of 78% (AUC=0.707; 95% CI=0.474-0.941; P=.095). MVR seems to be more accurate than MVA in determining the hemodynamic consequences of severe MS as determined by sPAP. In addition, preprocedural MVR detected successful PBMVs. © 2017, Wiley Periodicals, Inc.

  4. Peptide fingerprinting of Alzheimer's disease in cerebrospinal fluid: identification and prospective evaluation of new synaptic biomarkers.

    PubMed

    Jahn, Holger; Wittke, Stefan; Zürbig, Petra; Raedler, Thomas J; Arlt, Sönke; Kellmann, Markus; Mullen, William; Eichenlaub, Martin; Mischak, Harald; Wiedemann, Klaus

    2011-01-01

    Today, dementias are diagnosed late in the course of disease. Future treatments have to start earlier in the disease process to avoid disability requiring new diagnostic tools. The objective of this study is to develop a new method for the differential diagnosis and identification of new biomarkers of Alzheimer's disease (AD) using capillary-electrophoresis coupled to mass-spectrometry (CE-MS) and to assess the potential of early diagnosis of AD. Cerebrospinal fluid (CSF) of 159 out-patients of a memory-clinic at a University Hospital suffering from neurodegenerative disorders and 17 cognitively-healthy controls was used to create differential peptide pattern for dementias and prospective blinded-comparison of sensitivity and specificity for AD diagnosis against the Criterion standard in a naturalistic prospective sample of patients. Sensitivity and specificity of the new method compared to standard diagnostic procedures and identification of new putative biomarkers for AD was the main outcome measure. CE-MS was used to reliably detect 1104 low-molecular-weight peptides in CSF. Training-sets of patients with clinically secured sporadic Alzheimer's disease, frontotemporal dementia, and cognitively healthy controls allowed establishing discriminative biomarker pattern for diagnosis of AD. This pattern was already detectable in patients with mild cognitive impairment (MCI). The AD-pattern was tested in a prospective sample of patients (n = 100) and AD was diagnosed with a sensitivity of 87% and a specificity of 83%. Using CSF measurements of beta-amyloid1-42, total-tau, and phospho(181)-tau, AD-diagnosis had a sensitivity of 88% and a specificity of 67% in the same sample. Sequence analysis of the discriminating biomarkers identified fragments of synaptic proteins like proSAAS, apolipoprotein J, neurosecretory protein VGF, phospholemman, and chromogranin A. The method may allow early differential diagnosis of various dementias using specific peptide fingerprints and identification of incipient AD in patients suffering from MCI. Identified biomarkers facilitate face validity for the use in AD diagnosis.

  5. Familial aggregation of food allergy and sensitization to food allergens: a family-based study.

    PubMed

    Tsai, H-J; Kumar, R; Pongracic, J; Liu, X; Story, R; Yu, Y; Caruso, D; Costello, J; Schroeder, A; Fang, Y; Demirtas, H; Meyer, K E; O'Gorman, M R G; Wang, X

    2009-01-01

    The increasing prevalence of food allergy (FA) is a growing clinical and public health problem. The contribution of genetic factors to FA remains largely unknown. This study examined the pattern of familial aggregation and the degree to which genetic factors contribute to FA and sensitization to food allergens. This study included 581 nuclear families (2,004 subjects) as part of an ongoing FA study in Chicago, IL, USA. FA was defined by a set of criteria including timing, clinical symptoms obtained via standardized questionnaire interview and corroborative specific IgE cut-offs for > or =95% positive predictive value (PPV) for food allergens measured by Phadia ImmunoCAP. Familial aggregation of FA as well as sensitization to food allergens was examined using generalized estimating equation (GEE) models, with adjustment for important covariates including age, gender, ethnicity and birth order. Heritability was estimated for food-specific IgE measurements. FA in the index child was a significant and independent predictor of FA in other siblings (OR=2.6, 95% CI: 1.2-5.6, P=0.01). There were significant and positive associations among family members (father-offspring, mother-offspring, index-other siblings) for total IgE and specific IgE to all the nine major food allergens tested in this sample (sesame, peanut, wheat, milk, egg white, soy, walnut, shrimp and cod fish). The estimated heritability of food-specific IgE ranged from 0.15 to 0.35 and was statistically significant for all the nine tested food allergens. This family-based study demonstrates strong familial aggregation of FA and sensitization to food allergens, especially, among siblings. The heritability estimates indicate that food-specific IgE is likely influenced by both genetic and environmental factors. Together, this study provides strong evidence that both host genetic susceptibility and environmental factors determine the complex trait of IgE-mediated FA.

  6. Comparison of ICD code-based diagnosis of obesity with measured obesity in children and the implications for health care cost estimates.

    PubMed

    Kuhle, Stefan; Kirk, Sara F L; Ohinmaa, Arto; Veugelers, Paul J

    2011-12-21

    Administrative health databases are a valuable research tool to assess health care utilization at the population level. However, their use in obesity research limited due to the lack of data on body weight. A potential workaround is to use the ICD code of obesity to identify obese individuals. The objective of the current study was to investigate the sensitivity and specificity of an ICD code-based diagnosis of obesity from administrative health data relative to the gold standard measured BMI. Linkage of a population-based survey with anthropometric measures in elementary school children in 2003 with longitudinal administrative health data (physician visits and hospital discharges 1992-2006) from the Canadian province of Nova Scotia. Measured obesity was defined based on the CDC cut-offs applied to the measured BMI. An ICD code-based diagnosis obesity was defined as one or more ICD-9 (278) or ICD-10 code (E66-E68) of obesity from a physician visit or a hospital stay. Sensitivity and specificity were calculated and health care cost estimates based on measured obesity and ICD-based obesity were compared. The sensitivity of an ICD code-based obesity diagnosis was 7.4% using ICD codes between 2002 and 2004. Those correctly identified had a higher BMI and had higher health care utilization and costs. An ICD diagnosis of obesity in Canadian administrative health data grossly underestimates the true prevalence of childhood obesity and overestimates the health care cost differential between obese and non-obese children.

  7. Proof of the quantitative potential of immunofluorescence by mass spectrometry.

    PubMed

    Toki, Maria I; Cecchi, Fabiola; Hembrough, Todd; Syrigos, Konstantinos N; Rimm, David L

    2017-03-01

    Protein expression in formalin-fixed, paraffin-embedded patient tissue is routinely measured by Immunohistochemistry (IHC). However, IHC has been shown to be subject to variability in sensitivity, specificity and reproducibility, and is generally, at best, considered semi-quantitative. Mass spectrometry (MS) is considered by many to be the criterion standard for protein measurement, offering high sensitivity, specificity, and objective molecular quantification. Here, we seek to show that quantitative immunofluorescence (QIF) with standardization can achieve quantitative results comparable to MS. Epidermal growth factor receptor (EGFR) was measured by quantitative immunofluorescence in 15 cell lines with a wide range of EGFR expression, using different primary antibody concentrations, including the optimal signal-to-noise concentration after quantitative titration. QIF target measurement was then compared to the absolute EGFR concentration measured by Liquid Tissue-selected reaction monitoring mass spectrometry. The best agreement between the two assays was found when the EGFR primary antibody was used at the optimal signal-to-noise concentration, revealing a strong linear regression (R 2 =0.88). This demonstrates that quantitative optimization of titration by calculation of signal-to-noise ratio allows QIF to be standardized to MS and can therefore be used to assess absolute protein concentration in a linear and reproducible manner.

  8. Metabolic syndrome in mental health and addiction treatment: a quantitative study.

    PubMed

    Flynn, M; Houtjes, W; Merks, A; van Mierlo, A; van de Wetering, B

    2015-02-01

    Patients with mental illnesses have been found to shorter life expectancy due to an increased risk of heart disease. Some medication used to treat mental illnesses have been linked to weight gain and other physical change that make patients susceptible to heart disease. In order to reduce this risk it is important that health professionals regularly measure and monitor signs of these physical changes. This research has found that measuring both waist circumference and blood pressure of patients is a safe and reliable way to way to monitor patients. To identify if combined blood pressure and waist circumference measurements are reliable predictor of metabolic syndrome, a descriptive correlational design was used to examine the sensitivity and specificity of screening techniques used to detect metabolic syndrome. Data were collected regarding waist circumference, body mass index, blood pressure, fasting blood glucose, triglycerides and high-density lipoproteins. Blood pressure and waist circumference measurements demonstrated high significance, sensitivity and specificity as screening instruments for metabolic syndrome. Combined waist circumference and blood pressure measurements may be clinically useful for a quick and reliable detection of metabolic syndrome in patients with addiction and comorbid mental health problems. © 2014 John Wiley & Sons Ltd.

  9. Status of the project TRAPSENSOR: Performance of the laser-desorption ion source

    NASA Astrophysics Data System (ADS)

    Cornejo, J. M.; Lorenzo, A.; Renisch, D.; Block, M.; Düllmann, Ch. E.; Rodríguez, D.

    2013-12-01

    Penning traps provide mass measurements on atomic nuclei with the highest accuracy and sensitivity. Depending on the experiment and on the physics goal, a relative mass uncertainty varying from 10-7 to below 10-11 is required. Regarding sensitivity, the use of only one ion for the measurement is crucial, either to perform mass measurements on superheavy elements (SHE), or to reach δm/m≈10-11 in order to contribute to the direct determination of the mass of the electron-antineutrino with accurate mass measurements on specific nuclei. This has motivated the development of a new technique called Quantum Sensor based on a laser-cooled ion stored in a Penning trap, to perform mass measurements using fluorescence photons instead of electronic detection. The device is currently under development at the University of Granada (Spain) within the project TRAPSENSOR. We describe the physics which motivates the construction of this device, the expected performance of the Quantum Sensor compared to that from existing techniques, and briefly present the main components of the project. As a specific aspect of the project, the performance of the laser-desorption ion source utilized to produce calcium, rhenium and osmium ions at different kinetic energies is presented.

  10. Magnetic resonance imaging and magnetic resonance spectroscopy for detection of early Alzheimer's disease.

    PubMed

    Westman, Eric; Wahlund, Lars-Olof; Foy, Catherine; Poppe, Michaela; Cooper, Allison; Murphy, Declan; Spenger, Christian; Lovestone, Simon; Simmons, Andrew

    2011-01-01

    Alzheimer's disease is the most common form of neurodegenerative disorder and early detection is of great importance if new therapies are to be effectively administered. We have investigated whether the discrimination between early Alzheimer's disease (AD) and elderly healthy control subjects can be improved by adding magnetic resonance spectroscopy (MRS) measures to magnetic resonance imaging (MRI) measures. In this study 30 AD patients and 36 control subjects were included. High resolution T1-weighted axial magnetic resonance images were obtained from each subject. Automated regional volume segmentation and cortical thickness measures were determined for the images. 1H MRS was acquired from the hippocampus and LCModel was used for metabolic quantification. Altogether, this yielded 58 different volumetric, cortical thickness and metabolite ratio variables which were used for multivariate analysis to distinguish between subjects with AD and Healthy controls. Combining MRI and MRS measures resulted in a sensitivity of 97% and a specificity of 94% compared to using MRI or MRS measures alone (sensitivity: 87%, 76%, specificity: 86%, 83% respectively). Adding the MRS measures to the MRI measures more than doubled the positive likelihood ratio from 6 to 17. Adding MRS measures to a multivariate analysis of MRI measures resulted in significantly better classification than using MRI measures alone. The method shows strong potential for discriminating between Alzheimer's disease and controls.

  11. Genomic testing to determine drug response: measuring preferences of the public and patients using Discrete Choice Experiment (DCE)

    PubMed Central

    2013-01-01

    Background The extent to which a genomic test will be used in practice is affected by factors such as ability of the test to correctly predict response to treatment (i.e. sensitivity and specificity of the test), invasiveness of the testing procedure, test cost, and the probability and severity of side effects associated with treatment. Methods Using discrete choice experimentation (DCE), we elicited preferences of the public (Sample 1, N = 533 and Sample 2, N = 525) and cancer patients (Sample 3, N = 38) for different attributes of a hypothetical genomic test for guiding cancer treatment. Samples 1 and 3 considered the test/treatment in the context of an aggressive curable cancer (scenario A) while the scenario for sample 2 was based on a non-aggressive incurable cancer (scenario B). Results In aggressive curable cancer (scenario A), everything else being equal, the odds ratio (OR) of choosing a test with 95% sensitivity was 1.41 (versus a test with 50% sensitivity) and willingness to pay (WTP) was $1331, on average, for this amount of improvement in test sensitivity. In this scenario, the OR of choosing a test with 95% specificity was 1.24 times that of a test with 50% specificity (WTP = $827). In non-aggressive incurable cancer (scenario B), the OR of choosing a test with 95% sensitivity was 1.65 (WTP = $1344), and the OR of choosing a test with 95% specificity was 1.50 (WTP = $1080). Reducing severity of treatment side effects from severe to mild was associated with large ORs in both scenarios (OR = 2.10 and 2.24 in scenario A and B, respectively). In contrast, patients had a very large preference for 95% sensitivity of the test (OR = 5.23). Conclusion The type and prognosis of cancer affected preferences for genomically-guided treatment. In aggressive curable cancer, individuals emphasized more on the sensitivity rather than the specificity of the test. In contrast, for a non-aggressive incurable cancer, individuals put similar emphasis on sensitivity and specificity of the test. While the public expressed strong preference toward lowering severity of side effects, improving sensitivity of the test had by far the largest influence on patients’ decision to use genomic testing. PMID:24176050

  12. Sensitivity and specificity of unenhanced MR mammography (DWI combined with T2-weighted TSE imaging, ueMRM) for the differentiation of mass lesions.

    PubMed

    Baltzer, Pascal A T; Benndorf, Matthias; Dietzel, Matthias; Gajda, Mieczyslaw; Camara, Oumar; Kaiser, Werner A

    2010-05-01

    This study was performed to assess the sensitivity and specificity for malignant and benign mass lesions of a diagnostic approach combining DWI with T2-weighted images (unenhanced MR mammography, ueMRM) and compare the results with contrast-enhanced MR mammography (ceMRM). Consecutive patients undergoing histopathological verification of mass lesions after MR mammography without prior breast interventions (contrast-enhanced T1-weighted, T2-weighted and DWI sequences) were eligible for this retrospective investigation. Two blinded observers first rated ueMRM and then ceMRM according to the BIRADS scale. Lesion size, ADC values and T2-weighted TSE descriptors were assessed. This study examined 81 lesions (27 benign, 54 malignant). Sensitivity of ueMRM was 93% (observer 1) and 86% (observer 2), respectively. Sensitivity of ceMRM was 96.5% (observer 1) and 98.3% (observer 2). Specificity was 85.2% (ueMRM) and 92.6% (ceMRM) for both observers. The differences between both methods and observers were not significant (P > or = 0.09). Lesion size measurements did not differ significantly among all sequences analyzed. Tumor visibility was worse using ueMRM for both benign (P < 0.001) and malignant lesions (P = 0.004). Sensitivity and specificity of ueMRM in mass lesions equal that of ceMRM. However, a reduced lesion visibility in ueMRM may lead to more false-negative findings.

  13. Sensitive Indicators of Zonal Stipa Species to Changing Temperature and Precipitation in Inner Mongolia Grassland, China

    PubMed Central

    Lv, Xiaomin; Zhou, Guangsheng; Wang, Yuhui; Song, Xiliang

    2016-01-01

    Climate change often induces shifts in plant functional traits. However, knowledge related to sensitivity of different functional traits and sensitive indicator representing plant growth under hydrothermal change remains unclear. Inner Mongolia grassland is predicted to be one of the terrestrial ecosystems which are most vulnerable to climate change. In this study, we analyzed the response of four zonal Stipa species (S. baicalensis, S. grandis, S. breviflora, and S. bungeana) from Inner Mongolia grassland to changing temperature (control, increased 1.5, 2, 4, and 6°C), precipitation (decreased 30 and 15%, control, increased 15 and 30%) and their combined effects via climate control chambers. The relative change of functional traits in the unit of temperature and precipitation change was regarded as sensitivity coefficient and sensitive indicators were examined by pathway analysis. We found that sensitivity of the four Stipa species to changing temperature and precipitation could be ranked as follows: S. bungeana > S. grandis > S. breviflora > S. baicalensis. In particular, changes in leaf area, specific leaf area and root/shoot ratio could account for 86% of the changes in plant biomass in the four Stipa species. Also these three measurements were more sensitive to hydrothermal changes than the other functional traits. These three functional indicators reflected the combination of plant production capacity (leaf area), adaptive strategy (root/shoot ratio), instantaneous environmental effects (specific leaf area), and cumulative environmental effects (leaf area and root/shoot ratio). Thus, leaf area, specific leaf area and root/shoot ratio were chosen as sensitive indicators in response to changing temperature and precipitation for Stipa species. These results could provide the basis for predicting the influence of climate change on Inner Mongolia grassland based on the magnitude of changes in sensitive indicators. PMID:26904048

  14. Attention Measures of Accuracy, Variability, and Fatigue Detect Early Response to Donepezil in Alzheimer's Disease: A Randomized, Double-blind, Placebo-Controlled Pilot Trial.

    PubMed

    Vila-Castelar, Clara; Ly, Jenny J; Kaplan, Lillian; Van Dyk, Kathleen; Berger, Jeffrey T; Macina, Lucy O; Stewart, Jennifer L; Foldi, Nancy S

    2018-04-09

    Donepezil is widely used to treat Alzheimer's disease (AD), but detecting early response remains challenging for clinicians. Acetylcholine is known to directly modulate attention, particularly under high cognitive conditions, but no studies to date test whether measures of attention under high load can detect early effects of donepezil. We hypothesized that load-dependent attention tasks are sensitive to short-term treatment effects of donepezil, while global and other domain-specific cognitive measures are not. This longitudinal, randomized, double-blind, placebo-controlled pilot trial (ClinicalTrials.gov Identifier: NCT03073876) evaluated 23 participants newly diagnosed with AD initiating de novo donepezil treatment (5 mg). After baseline assessment, participants were randomized into Drug (n = 12) or Placebo (n = 11) groups, and retested after approximately 6 weeks. Cognitive assessment included: (a) attention tasks (Foreperiod Effect, Attentional Blink, and Covert Orienting tasks) measuring processing speed, top-down accuracy, orienting, intra-individual variability, and fatigue; (b) global measures (Alzheimer's Disease Assessment Scale-Cognitive Subscale, Mini-Mental Status Examination, Dementia Rating Scale); and (c) domain-specific measures (memory, language, visuospatial, and executive function). The Drug but not the Placebo group showed benefits of treatment at high-load measures by preserving top-down accuracy, improving intra-individual variability, and averting fatigue. In contrast, other global or cognitive domain-specific measures could not detect treatment effects over the same treatment interval. The pilot-study suggests that attention measures targeting accuracy, variability, and fatigue under high-load conditions could be sensitive to short-term cholinergic treatment. Given the central role of acetylcholine in attentional function, load-dependent attentional measures may be valuable cognitive markers of early treatment response.

  15. Indoor allergens, environmental avoidance, and allergic respiratory disease.

    PubMed

    Bush, Robert K

    2008-01-01

    Indoor allergen exposure to sources such as house-dust mites, pets, fungi, and insects plays a significant role in patients with allergic rhinitis and asthma. The identification of the major allergens has led to methods that can quantitate exposure, e.g., immunoassays for Der p 1 in settled dust samples. Sensitization and the development of allergic respiratory disease result from complex genetic and environmental interactions. New paradigms that examine the role of other environmental factors, including exposure to proteases that can activate eosinophils and initiate Th2 responses, and epigenetics, are being explored. Recommendations for specific environmental allergen avoidance measures are discussed for house-dust mites, cockroaches, animal dander, and fungi. Specific measures to reduce indoor allergen exposure when vigorously applied may reduce the risk of sensitization and symptoms of allergic respiratory disease, although further research will be necessary to establish cost-effective approaches.

  16. Sensitive, site-specific, and stable vibrational probe of local protein environments: 4-azidomethyl-L-phenylalanine.

    PubMed

    Bazewicz, Christopher G; Liskov, Melanie T; Hines, Kevin J; Brewer, Scott H

    2013-08-01

    We have synthesized the unnatural amino acid (UAA), 4-azidomethyl-L-phenylalanine (pN₃CH₂Phe), to serve as an effective vibrational reporter of local protein environments. The position, extinction coefficient, and sensitivity to local environment of the azide asymmetric stretch vibration of pN₃CH₂Phe are compared to the vibrational reporters: 4-cyano-L-phenylalanine (pCNPhe) and 4-azido-L-phenylalanine (pN₃Phe). This UAA was genetically incorporated in a site-specific manner utilizing an engineered, orthogonal aminoacyl-tRNA synthetase in response to an amber codon with high efficiency and fidelity into two distinct sites in superfolder green fluorescent protein (sfGFP). This allowed for the dependence of the azide asymmetric stretch vibration of pN₃CH₂Phe to different protein environments to be measured. The photostability of pN₃CH₂Phe was also measured relative to the photoreactive UAA, pN₃Phe.

  17. The Rey Auditory Verbal Learning Test forced-choice recognition task: Base-rate data and norms.

    PubMed

    Poreh, Amir; Bezdicek, Ondrej; Korobkova, Irina; Levin, Jennifer B; Dines, Philipp

    2016-01-01

    The present study describes a novel Forced-Choice Response (FCR) index for detecting poor effort on the Rey Auditory Verbal Learning Test (RAVLT). This retrospective study analyzes the performance of 4 groups on the new index: clinically referred patients with suspected dementia, forensic patients identified as not exhibiting adequate effort on other measures of response bias, students who simulated poor effort, and a large normative sample collected in the Gulf State of Oman. Using sensitivity and specificity analyses, the study shows that much like the California Verbal Learning Test-Second Edition FCR index, the RAVLT FCR index misses a proportion of individuals with inadequate effort (low sensitivity), but those who fail this measure are highly likely to be exhibiting poor effort (high specificity). The limitations and benefits of utilizing the RAVLT FCR index in clinical practice are discussed.

  18. Sensitivity and specificity of modified 100-g oral glucose tolerance tests for diagnosis of gestational diabetes mellitus.

    PubMed

    Hansarikit, Jarunee; Manotaya, Saknan

    2011-05-01

    To study the sensitivity and specificity of the modified 100-g oral glucose tolerance test for diagnosis of gestational diabetes mellitus (GDM). Medical records of pregnant women attending the antenatal clinic of King Chulalongkorn Memorial Hospital, Thailand, who underwent a 100-g oral glucose tolerance test (OGTT) during March 2004 to September 2009, were retrospectively reviewed. Three modified criteria were proposed for diagnosis of GDM. The screening efficacy of the modified criteria were assessed, using the National Diabetes Data Group (NDDG) criterion as gold standard. A total of 729 records were reviewed, 511 were included for analysis. Using the NDDG criterion as the gold standard, the modified II criterion has the highest sensitivity of 96.8%, and the highest accuracy of 90.8%. The modified II criterion can detect the same proportion of maternal and neonatal complications, compared to the NDDG criterion. The modified II criterion, using the fasting plasma glucose and 2-hour plasma glucose measurements, showed high sensitivity and accuracy, with moderate specificity for diagnosis of GDM. Its potential use as an alternative to standard 100-g OGTT should be evaluated in the prospective study.

  19. Evaluating the validity of self-reported smoking in Mexican adolescents

    PubMed Central

    Valladolid-López, María del Carmen; Barrientos-Gutiérrez, Tonatiuh; Reynales-Shigematsu, Luz Myriam; Thrasher, James F; Peláez-Ballestas, Ingris; Lazcano-Ponce, Eduardo; Hernández-Ávila, Mauricio

    2015-01-01

    Objectives We aimed to evaluate the validity of the self-reported smoking indicator used in the Global Youth Tobacco Survey (GYTS). Setting 43 middle and high-school classrooms from 26 schools were selected from Mexico City and Cuernavaca, Morelos. Participants A total of 1257 students provided both a questionnaire and a urine sample. Primary and secondary outcome Sensitivity and specificity of self-reported smoking compared to urinary cotinine. Validity indices were evaluated by subgroups of gender, social acceptability of smoking (ie, smoking parents or friends) and smoking frequency. Results Sensitivity and specificity for current smoking were 93.2% and 81.7%, respectively. Validity indices remained stable across gender. Parental smoking status moderated the validity of self-report, which had lower sensitivity in adolescents with non-smoking parents (86.7%) than in adolescents with smoking parents (96.6%). Sensitivity and specificity increased with smoking frequency. Conclusions This first validation study of self-reported current smoking used in the GYTS among Mexican adolescents suggests that self-reported smoking in the past 30 days is a valid and stable indicator of current smoking behaviour. This measure appears suitable for public health research and surveillance. PMID:26453588

  20. A highly sensitive and specific capacitive aptasensor for rapid and label-free trace analysis of Bisphenol A (BPA) in canned foods.

    PubMed

    Mirzajani, Hadi; Cheng, Cheng; Wu, Jayne; Chen, Jiangang; Eda, Shigotoshi; Najafi Aghdam, Esmaeil; Badri Ghavifekr, Habib

    2017-03-15

    A rapid, highly sensitive, specific and low-cost capacitive affinity biosensor is presented here for label-free and single step detection of Bisphenol A (BPA). The sensor design allows rapid prototyping at low-cost using printed circuit board material by benchtop equipment. High sensitivity detection is achieved through the use of a BPA-specific aptamer as probe molecule and large electrodes to enhance AC-electroelectrothermal effect for long-range transport of BPA molecules toward electrode surface. Capacitive sensing technique is used to determine the bounded BPA level by measuring the sample/electrode interfacial capacitance of the sensor. The developed biosensor can detect BPA level in 20s and exhibits a large linear range from 1 fM to 10 pM, with a limit of detection (LOD) of 152.93 aM. This biosensor was applied to test BPA in canned food samples and could successfully recover the levels of spiked BPA. This sensor technology is demonstrated to be highly promising and reliable for rapid, sensitive and on-site monitoring of BPA in food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis

    PubMed Central

    Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.

    2014-01-01

    Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240

  2. Development of a human-specific B. thetaiotaomicron IMS ...

    EPA Pesticide Factsheets

    Immunomagnetic separation/adenosine triphosphate (IMS/ATP) assays utilize paramagnetic beads and target-specific antibodies to isolate target organisms. Following isolation, adenosine tri-phosphate (ATP) is extracted from the target population and quantified. An inversely-coupled (Inv-IMS/ATP)assay for detection of Bacteroides thetaiotaomicron was developed and applied for rapid detection of human-associated fecal contamination in surface waters in Baja California. Specificity of the assay was tested against challenge solutions of varying concentrations of dog, gull, horse and chicken feces, and a field validation survey of coastal and WWTP effluent water quality in Rosarito and Enseneda, Baja California was conducted. Inv IMS/ATP measurements made shown to be specific and sensitive to human fecal contamination. At test concentrations of less than 1000 MPN ENT/100 mL, sensitivity and specificity of the assay both exceeded 80%. Moreover, the Inv-IMS/ATP assay yielded measurements of viable B. thetaiotaomicron that were comparable to the HF183 human marker in complex surface waters impacted with both wastewater and runoff, and the Inv-IMS/ATP assay was able to effectively differentiate between surface waters impacted with adequately and inadequately treated wastewater. The Inv-IMS/ATP assays shows promise for rapid evaluation of recreational water quality in areas where access to more expensive methods is limited and in areas where water quality in unpredicta

  3. Validation of sick leave measures: self-reported sick leave and sickness benefit data from a Danish national register compared to multiple workplace-registered sick leave spells in a Danish municipality

    PubMed Central

    2012-01-01

    Background Previous validation studies of sick leave measures have focused on self-reports. Register-based sick leave data are considered to be valid; however methodological problems may be associated with such data. A Danish national register on sickness benefit (DREAM) has been widely used in sick leave research. On the basis of sick leave records from 3,554 and 2,311 eldercare workers in 14 different workplaces, the aim of this study was to: 1) validate registered sickness benefit data from DREAM against workplace-registered sick leave spells of at least 15 days; 2) validate self-reported sick leave days during one year against workplace-registered sick leave. Methods Agreement between workplace-registered sick leave and DREAM-registered sickness benefit was reported as sensitivities, specificities and positive predictive values. A receiver-operating characteristic curve and a Bland-Altman plot were used to study the concordance with sick leave duration of the first spell. By means of an analysis of agreement between self-reported and workplace-registered sick leave sensitivity and specificity was calculated. Ninety-five percent confidence intervals (95% CI) were used. Results The probability that registered DREAM data on sickness benefit agrees with workplace-registered sick leave of at least 15 days was 96.7% (95% CI: 95.6-97.6). Specificity was close to 100% (95% CI: 98.3-100). The registered DREAM data on sickness benefit overestimated the duration of sick leave spells by an average of 1.4 (SD: 3.9) weeks. Separate analysis on pregnancy-related sick leave revealed a maximum sensitivity of 20% (95% CI: 4.3-48.1). The sensitivity of self-reporting at least one or at least 56 sick leave day/s was 94.5 (95% CI: 93.4 – 95.5) % and 58.5 (95% CI: 51.1 – 65.6) % respectively. The corresponding specificities were 85.3 (95% CI: 81.4 – 88.6) % and 98.9 (95% CI: 98.3 – 99.3) %. Conclusions The DREAM register offered valid measures of sick leave spells of at least 15 days among eldercare employees. Pregnancy-related sick leave should be excluded in studies planning to use DREAM data on sickness benefit. Self-reported sick leave became more imprecise when number of absence days increased, but the sensitivity and specificity were acceptable for lengths not exceeding one week. PMID:22894644

  4. Validation of sick leave measures: self-reported sick leave and sickness benefit data from a Danish national register compared to multiple workplace-registered sick leave spells in a Danish municipality.

    PubMed

    Stapelfeldt, Christina Malmose; Jensen, Chris; Andersen, Niels Trolle; Fleten, Nils; Nielsen, Claus Vinther

    2012-08-15

    Previous validation studies of sick leave measures have focused on self-reports. Register-based sick leave data are considered to be valid; however methodological problems may be associated with such data. A Danish national register on sickness benefit (DREAM) has been widely used in sick leave research. On the basis of sick leave records from 3,554 and 2,311 eldercare workers in 14 different workplaces, the aim of this study was to: 1) validate registered sickness benefit data from DREAM against workplace-registered sick leave spells of at least 15 days; 2) validate self-reported sick leave days during one year against workplace-registered sick leave. Agreement between workplace-registered sick leave and DREAM-registered sickness benefit was reported as sensitivities, specificities and positive predictive values. A receiver-operating characteristic curve and a Bland-Altman plot were used to study the concordance with sick leave duration of the first spell. By means of an analysis of agreement between self-reported and workplace-registered sick leave sensitivity and specificity was calculated. Ninety-five percent confidence intervals (95% CI) were used. The probability that registered DREAM data on sickness benefit agrees with workplace-registered sick leave of at least 15 days was 96.7% (95% CI: 95.6-97.6). Specificity was close to 100% (95% CI: 98.3-100). The registered DREAM data on sickness benefit overestimated the duration of sick leave spells by an average of 1.4 (SD: 3.9) weeks. Separate analysis on pregnancy-related sick leave revealed a maximum sensitivity of 20% (95% CI: 4.3-48.1).The sensitivity of self-reporting at least one or at least 56 sick leave day/s was 94.5 (95% CI: 93.4 - 95.5) % and 58.5 (95% CI: 51.1 - 65.6) % respectively. The corresponding specificities were 85.3 (95% CI: 81.4 - 88.6) % and 98.9 (95% CI: 98.3 - 99.3) %. The DREAM register offered valid measures of sick leave spells of at least 15 days among eldercare employees. Pregnancy-related sick leave should be excluded in studies planning to use DREAM data on sickness benefit. Self-reported sick leave became more imprecise when number of absence days increased, but the sensitivity and specificity were acceptable for lengths not exceeding one week.

  5. Measuring Adult Literacy in Health Care: Performance of the Newest Vital Sign

    ERIC Educational Resources Information Center

    Osborn, Chandra Y.; Weiss, Barry D.; Davis, Terry C.; Skripkauskas, Silvia; Rodrigue, Christopher; Bass, Pat F., III; Wolf, Michael S.

    2007-01-01

    Objective: To compare performance of the newest vital sign (NVS) with existing literacy measures. Methods: We administered the NVS and REALM to 129 patients, and NVS and S-TOFHLA to 119 patients all in public clinics. Results: The NVS demonstrated high sensitivity for detecting limited literacy and moderate specificity (area under the receiver…

  6. Quantitative Comparison of Protein Adsorption and Conformational Changes on Dielectric-Coated Nanoplasmonic Sensing Arrays.

    PubMed

    Ferhan, Abdul Rahim; Jackman, Joshua A; Sut, Tun Naw; Cho, Nam-Joon

    2018-04-22

    Nanoplasmonic sensors are a popular, surface-sensitive measurement tool to investigate biomacromolecular interactions at solid-liquid interfaces, opening the door to a wide range of applications. In addition to high surface sensitivity, nanoplasmonic sensors have versatile surface chemistry options as plasmonic metal nanoparticles can be coated with thin dielectric layers. Within this scope, nanoplasmonic sensors have demonstrated promise for tracking protein adsorption and substrate-induced conformational changes on oxide film-coated arrays, although existing studies have been limited to single substrates. Herein, we investigated human serum albumin (HSA) adsorption onto silica- and titania-coated arrays of plasmonic gold nanodisks by localized surface plasmon resonance (LSPR) measurements and established an analytical framework to compare responses across multiple substrates with different sensitivities. While similar responses were recorded on the two substrates for HSA adsorption under physiologically-relevant ionic strength conditions, distinct substrate-specific behavior was observed at lower ionic strength conditions. With decreasing ionic strength, larger measurement responses occurred for HSA adsorption onto silica surfaces, whereas HSA adsorption onto titania surfaces occurred independently of ionic strength condition. Complementary quartz crystal microbalance-dissipation (QCM-D) measurements were also performed, and the trend in adsorption behavior was similar. Of note, the magnitudes of the ionic strength-dependent LSPR and QCM-D measurement responses varied, and are discussed with respect to the measurement principle and surface sensitivity of each technique. Taken together, our findings demonstrate how the high surface sensitivity of nanoplasmonic sensors can be applied to quantitatively characterize protein adsorption across multiple surfaces, and outline broadly-applicable measurement strategies for biointerfacial science applications.

  7. "When the going gets tough, who keeps going?" Depletion sensitivity moderates the ego-depletion effect.

    PubMed

    Salmon, Stefanie J; Adriaanse, Marieke A; De Vet, Emely; Fennis, Bob M; De Ridder, Denise T D

    2014-01-01

    Self-control relies on a limited resource that can get depleted, a phenomenon that has been labeled ego-depletion. We argue that individuals may differ in their sensitivity to depleting tasks, and that consequently some people deplete their self-control resource at a faster rate than others. In three studies, we assessed individual differences in depletion sensitivity, and demonstrate that depletion sensitivity moderates ego-depletion effects. The Depletion Sensitivity Scale (DSS) was employed to assess depletion sensitivity. Study 1 employs the DSS to demonstrate that individual differences in sensitivity to ego-depletion exist. Study 2 shows moderate correlations of depletion sensitivity with related self-control concepts, indicating that these scales measure conceptually distinct constructs. Study 3 demonstrates that depletion sensitivity moderates the ego-depletion effect. Specifically, participants who are sensitive to depletion performed worse on a second self-control task, indicating a stronger ego-depletion effect, compared to participants less sensitive to depletion.

  8. “When the going gets tough, who keeps going?” Depletion sensitivity moderates the ego-depletion effect

    PubMed Central

    Salmon, Stefanie J.; Adriaanse, Marieke A.; De Vet, Emely; Fennis, Bob M.; De Ridder, Denise T. D.

    2014-01-01

    Self-control relies on a limited resource that can get depleted, a phenomenon that has been labeled ego-depletion. We argue that individuals may differ in their sensitivity to depleting tasks, and that consequently some people deplete their self-control resource at a faster rate than others. In three studies, we assessed individual differences in depletion sensitivity, and demonstrate that depletion sensitivity moderates ego-depletion effects. The Depletion Sensitivity Scale (DSS) was employed to assess depletion sensitivity. Study 1 employs the DSS to demonstrate that individual differences in sensitivity to ego-depletion exist. Study 2 shows moderate correlations of depletion sensitivity with related self-control concepts, indicating that these scales measure conceptually distinct constructs. Study 3 demonstrates that depletion sensitivity moderates the ego-depletion effect. Specifically, participants who are sensitive to depletion performed worse on a second self-control task, indicating a stronger ego-depletion effect, compared to participants less sensitive to depletion. PMID:25009523

  9. Working memory recall precision is a more sensitive index than span.

    PubMed

    Zokaei, Nahid; Burnett Heyes, Stephanie; Gorgoraptis, Nikos; Budhdeo, Sanjay; Husain, Masud

    2015-09-01

    Delayed adjustment tasks have recently been developed to examine working memory (WM) precision, that is, the resolution with which items maintained in memory are recalled. However, despite their emerging use in experimental studies of healthy people, evaluation of patient populations is sparse. We first investigated the validity of adjustment tasks, comparing precision with classical span measures of memory across the lifespan in 114 people. Second, we asked whether precision measures can potentially provide a more sensitive measure of WM than traditional span measures. Specifically, we tested this hypothesis examining WM in a group with early, untreated Parkinson's disease (PD) and its modulation by subsequent treatment on dopaminergic medication. Span measures correlated with precision across the lifespan: in children, young, and elderly participants. However, they failed to detect changes in WM in PD patients, either pre- or post-treatment initiation. By contrast, recall precision was sensitive enough to pick up such changes. PD patients pre-medication were significantly impaired compared to controls, but improved significantly after 3 months of being established on dopaminergic medication. These findings suggest that precision methods might provide a sensitive means to investigate WM and its modulation by interventions in clinical populations. © 2014 The Authors Journal of Neuropsychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.

  10. Measuring the Degree of Sensitization (DOS) Using an Electrochemical Technique

    NASA Astrophysics Data System (ADS)

    Abuzriba, Mokhtar B.; Musa, Salem M.

    Sensitization can be simply defined as the susceptibility of an alloy, specifically austenitic stainless steel, to corrosion at grain boundaries. A detailed study on types 304 stainless steel has been carried out to correlate the degree of sensitization measured by electrochemical potentiokinetic reactivation test (EPR) with the susceptibility to intergranular corrosion. In this study four different heat treatments were given to alloys, i.e., solution annealed (SA) at 1020 °C for 1 h, then quenched in water; also then heat-treated in air at 620 °C for 15, 30, and 60 min. The electrolyte for the EPR tests was 1.0 N H2SO4 solution containing 0.01 M KSCN. Potentiodynamic curves from passive to active regions in deaerated solution at room temperature were obtained at a scan rate of 1.67 mV/s (6 V/h), after the passivation at 200 mV versus (SCE) for 2 min then the polarization was conducted. The criterion used to distinguish between sensitized and non-sensitized specimens is the activation charge Pa, the peak current density, Ph, in the active state, and Flade potential Ef at which the active curve breaks upward. The results indicated that the longer the sensitization time the higher the activation charge (Pa), and the higher the peak current density in the active state (Ph). The results indicated that, the EPR is more sensitive than the chemical method for measuring the degree of sensitization.

  11. Classification accuracy of brief parent report measures of language development in Spanish-speaking toddlers.

    PubMed

    Guiberson, Mark; Rodríguez, Barbara L; Dale, Philip S

    2011-10-01

    The purpose of the current study was to examine the concurrent validity and classification accuracy of 3 parent report measures of language development in Spanish-speaking toddlers. Forty-five Spanish-speaking parents and their 2-year-old children participated. Twenty-three children had expressive language delays (ELDs) as determined through multiple sources of information, and 22 had typical language development (TD). Parents completed the Spanish version of the Ages and Stages Questionnaire (Spanish ASQ; Squires, Potter, & Bricker, 1999) and the short-form of the Inventarios del Desarrollo de Habilidades Comunicativas Palabras y Enunciados (INV-II; Jackson-Maldonado, Bates, & Thal, 1992; Jackson-Maldonado et al., 2003), which is the Spanish version of the MacArthur-Bates Communicative Development Inventories Words and Sentences form, and reported children's 3 longest utterances (M3L-W). Children were administered the Preschool Language Scale, Fourth Edition, Spanish Edition (SPLS-4; Zimmerman, Steiner, & Pond, 2002) at early childhood centers. All 3 parent report measures were significantly correlated with the SPLS-4, establishing their concurrent validity. Children with ELDs scored significantly lower than TD children on all 3 parent report measures. The Spanish ASQ demonstrated less than desirable levels of sensitivity and specificity; both the short-form INV-II and M3L-W measures demonstrated favorable sensitivity and specificity. Of these measures, M3L-W demonstrated the strongest classification accuracy qualities, including sensitivity, negative predictive value, and area under the receiver operating characteristics curve. The short-form INV-II and M3L-W demonstrated highly satisfactory classification accuracy of ELDs, but M3L-W demonstrated slightly stronger accuracy. These results indicate that these measures may be useful in screening for ELDs in Spanish-speaking toddlers.

  12. Sensitivity and specificity of a single emergency department measurement of urinary neutrophil gelatinase-associated lipocalin for diagnosing acute kidney injury.

    PubMed

    Nickolas, Thomas L; O'Rourke, Matthew J; Yang, Jun; Sise, Meghan E; Canetta, Pietro A; Barasch, Nicholas; Buchen, Charles; Khan, Faris; Mori, Kiyoshi; Giglio, James; Devarajan, Prasad; Barasch, Jonathan

    2008-06-03

    A single serum creatinine measurement cannot distinguish acute kidney injury from chronic kidney disease or prerenal azotemia. To test the sensitivity and specificity of a single measurement of urinary neutrophil gelatinase-associated lipocalin (NGAL) and other urinary proteins to detect acute kidney injury in a spectrum of patients. Prospective cohort study. Emergency department of Columbia University Medical Center, New York, New York. 635 patients admitted to the hospital with acute kidney injury, prerenal azotemia, chronic kidney disease, or normal kidney function. Diagnosis of acute kidney injury was based on the RIFLE (risk, injury, failure, loss, and end-stage) criteria and assigned by researchers who were blinded to experimental measurements. Urinary NGAL was measured by immunoblot, N-acetyl-beta-d-glucosaminidase (NAG) by enzyme measurement, alpha1-microglobulin and alpha(1)-acid glycoprotein by immunonephelometry, and serum creatinine by Jaffe kinetic reaction. Experimental measurements were not available to treating physicians. Patients with acute kidney injury had a significantly elevated mean urinary NGAL level compared with the other kidney function groups (416 microg/g creatinine [SD, 387]; P = 0.001). At a cutoff value of 130 microg/g creatinine, sensitivity and specificity of NGAL for detecting acute injury were 0.900 (95% CI, 0.73 to 0.98) and 0.995 (CI, 0.990 to 1.00), respectively, and positive and negative likelihood ratios were 181.5 (CI, 58.33 to 564.71) and 0.10 (CI, 0.03 to 0.29); these values were superior to those for NAG, alpha1-microglobulin, alpha1-acid glycoprotein, fractional excretion of sodium, and serum creatinine. In multiple logistic regression, urinary NGAL level was highly predictive of clinical outcomes, including nephrology consultation, dialysis, and admission to the intensive care unit (odds ratio, 24.71 [CI, 7.69 to 79.42]). All patients came from a single center. Few kidney biopsies were performed. A single measurement of urinary NGAL helps to distinguish acute injury from normal function, prerenal azotemia, and chronic kidney disease and predicts poor inpatient outcomes.

  13. Repeatability and validity of a field kit for estimation of cholinesterase in whole blood.

    PubMed Central

    London, L; Thompson, M L; Sacks, S; Fuller, B; Bachmann, O M; Myers, J E

    1995-01-01

    OBJECTIVES--To evaluate a spectrophotometric field kit (Test-Mate-OP) for repeatability and validity in comparison with reference laboratory methods and to model its anticipated sensitivity and specificity based on these findings. METHODS--76 farm workers between the age of 20 and 55, of whom 30 were pesticide applicators exposed to a range of organophosphates in the preceding 10 days, had blood taken for plasma cholinesterase (PCE) and erythrocyte cholinesterase (ECE) measurement by field kit or laboratory methods. Paired blinded duplicate samples were taken from subgroups in the sample to assess repeatability of laboratory and field kit methods. Field kits were also used to test venous blood in one subgroup. The variance obtained for the field kit tests was then applied to two hypothetical scenarios that used published action guidelines to model the kit's sensitivity and specificity. RESULTS--Repeatability for PCE was much poorer and for ECE slightly poorer than that of laboratory measures. A substantial upward bias for field kit ECE relative to laboratory measurements was found. Sensitivity of the kit to a 40% drop in PCE was 67%, whereas that for ECE was 89%. Specificity of the kit with no change in mean of the population was 100% for ECE and 91% for PCE. CONCLUSION--Field kit ECE estimation seems to be sufficiently repeatable for surveillance activities, whereas PCE does not. Repeatability of both tests seems to be too low for use in epidemiological dose-response investigations. Further research is indicated to characterise the upward bias in ECE estimation on the kit. PMID:7697143

  14. In vivo tumor identification of colorectal liver metastases with diffuse reflectance and fluorescence spectroscopy.

    PubMed

    Tanis, Erik; Evers, Danny J; Spliethoff, Jarich W; Pully, Vishnu V; Kuhlmann, Koert; van Coevorden, Frits; Hendriks, Benno H W; Sanders, Joyce; Prevoo, Warner; Ruers, Theo J M

    2016-11-01

    Over the last decade, an increasing effort has been put towards the implementation of optical guidance techniques to aid surgeons during cancer surgery. Diffuse reflectance spectroscopy (DRS) and fluorescence spectroscopy (FS) are two of these new techniques. The objective of this study is to investigate whether in vivo optical spectroscopy is able to accurately discriminate colorectal liver metastases (CRLM) from normal liver tissue in vivo. DRS and FS were incorporated at the tip of a needle and were used for in vivo tissue differentiation during resection of CRLM. Measurements were taken in and around the tumor lesions and measurement sites were marked and correlated to histology (i.e., normal liver tissue or tumor tissue). Patients with and without neoadjuvant systemic chemotherapy were included into the study. Four hundred and eighty-four measurements were taken in and near 19 liver lesions prior to resection. Overall sensitivity and specificity for DRS was 95% and 92%, respectively. Bile was the most discriminative parameter. The addition of FS did not improve the overall accuracy. Sensitivity and specificity was not hampered by neo-adjuvant chemotherapy; sensitivity and specificity after neo-adjuvant chemotherapy were 92% and 100%, respectively. We have successfully integrated spectroscopy technology into a disposable 15 Gauge optical needle and we have shown that DRS and FS can accurately discriminate CRLM from normal liver tissue in the in vivo setting regardless of whether the patient was pre-treated with systemic therapy. This technique makes in vivo guidance accessible for common surgical practice. Lasers Surg. Med. 48:820-827, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Assessment of two alternative standardised tests for the vascular component of the hand-arm vibration syndrome (HAVS).

    PubMed

    Ye, Ying; Griffin, Michael J

    2016-10-01

    Vibration-induced white finger (VWF) is the vascular component of the hand-arm vibration syndrome (HAVS). Two tests have been standardised so as to assist the diagnosis of VWF: the measurement of finger rewarming times and the measurement of finger systolic blood pressures (FSBPs). This study investigates whether the two tests distinguish between fingers with and without symptoms of whiteness and compares individual results between the two test methods. In 60 men reporting symptoms of the HAVS, the times for their fingers to rewarm by 4°C (after immersion in 15°C water for 5 min) and FSBPs at 30°C, 15°C and 10°C were measured on the same day. There were significant increases in finger rewarming times and significant reductions in FSBPs at both 15°C and 10°C in fingers reported to suffer blanching. The FSBPs had sensitivities and specificities >90%, whereas the finger rewarming test had a sensitivity of 77% and a specificity of 79%. Fingers having longer rewarming times had lower FSBPs at both temperatures. The findings suggest that, when the test conditions are controlled according to the relevant standard, finger rewarming times and FSBPs can provide useful information for the diagnosis of VWF, although FSBPs are more sensitive and more specific. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Evaluation of a Commercial Glycoprotein Enzyme-Linked Immunosorbent Assay for Measuring Vaccine Immunity to Varicella

    PubMed Central

    Kim, Yun Hwa; Hwang, Ji Young; Shim, Hye Min; Lee, Eunsil; Park, Songyong

    2014-01-01

    Purpose To evaluate a recently marketed commercial glycoprotein enzyme-linked immunosorbent assay (gpEIA) kit, the VaccZyme™ VZV gpEIA, for measuring the immunity of varicella-vaccinated children. Materials and Methods We investigated the accuracy and reproducibility of the VaccZyme™ VZV gpEIA kit for the detection of antibodies to VZV. We also examined the sensitivity, specificity, and correlation between antibody titers calculated with gpEIA versus fluorescent antibody to membrane antigen (FAMA) by using sera of 349 children, ranging from 1 to 6 years old. Results VaccZyme™ VZV gpEIA gave precise and reproducible intra- and inter-assay results. FAMA and gpEIA titers showed a linear correlation (Pearson correlation coefficient=0.987). The sensitivity and specificity of the VaccZyme™ gpEIA was 31.4% and 100%, respectively, when the guidelines of the gpEIA (<100 mIU/mL) and FAMA 1:4 were adopted as cutoff values. However, the maximum sensitivity and specificity were 88.9% and 95.1%, respectively, with the highest correlation (κ=0.840), if the cutoff values were set with gpEIA at 49.7 mIU/mL and FAMA 1:16. Conclusion These results demonstrate that the VaccZyme™ VZV gpEIA kit gave precise and reproducible data for measuring antibody titer after varicella vaccination. The results also showed that the antibody titer calculated with the VaccZyme™ gpEIA kit strongly correlated with the FAMA titer. However, cutoff values should be re-optimized for the evaluation of vaccine immunity. PMID:24532518

  17. A global analysis of traits predicting species sensitivity to habitat fragmentation

    USGS Publications Warehouse

    Keinath, Douglas; Doak, Daniel F.; Hodges, Karen E.; Prugh, Laura R.; Fagan, William F.; Sekercioglu, Cagan H.; Buchart, Stuart H. M.; Kauffman, Matthew J.

    2017-01-01

    AimElucidating patterns in species responses to habitat fragmentation is an important focus of ecology and conservation, but studies are often geographically restricted, taxonomically narrow or use indirect measures of species vulnerability. We investigated predictors of species presence after fragmentation using data from studies around the world that included all four terrestrial vertebrate classes, thus allowing direct inter-taxonomic comparison.LocationWorld-wide.MethodsWe used generalized linear mixed-effect models in an information theoretic framework to assess the factors that explained species presence in remnant habitat patches (3342 patches; 1559 species, mostly birds; and 65,695 records of patch-specific presence–absence). We developed a novel metric of fragmentation sensitivity, defined as the maximum rate of change in probability of presence with changing patch size (‘Peak Change’), to distinguish between general rarity on the landscape and sensitivity to fragmentation per se.ResultsSize of remnant habitat patches was the most important driver of species presence. Across all classes, habitat specialists, carnivores and larger species had a lower probability of presence, and those effects were substantially modified by interactions. Sensitivity to fragmentation (measured by Peak Change) was influenced primarily by habitat type and specialization, but also by fecundity, life span and body mass. Reptiles were more sensitive than other classes. Grassland species had a lower probability of presence, though sample size was relatively small, but forest and shrubland species were more sensitive.Main conclusionsHabitat relationships were more important than life-history characteristics in predicting the effects of fragmentation. Habitat specialization increased sensitivity to fragmentation and interacted with class and habitat type; forest specialists and habitat-specific reptiles were particularly sensitive to fragmentation. Our results suggest that when conservationists are faced with disturbances that could fragment habitat they should pay particular attention to specialists, particularly reptiles. Further, our results highlight that the probability of presence in fragmented landscapes and true sensitivity to fragmentation are predicted by different factors.

  18. Recognition of depressive symptoms by physicians.

    PubMed

    Henriques, Sergio Gonçalves; Fráguas, Renério; Iosifescu, Dan V; Menezes, Paulo Rossi; Lucia, Mara Cristina Souza de; Gattaz, Wagner Farid; Martins, Milton Arruda

    2009-01-01

    To investigate the recognition of depressive symptoms of major depressive disorder (MDD) by general practitioners. MDD is underdiagnosed in medical settings, possibly because of difficulties in the recognition of specific depressive symptoms. A cross-sectional study of 316 outpatients at their first visit to a teaching general hospital. We evaluated the performance of 19 general practitioners using Primary Care Evaluation of Mental Disorders (PRIME-MD) to detect depressive symptoms and compared them to 11 psychiatrists using Structured Clinical Interview Axis I Disorders, Patient Version (SCID I/P). We measured likelihood ratios, sensitivity, specificity, and false positive and false negative frequencies. The lowest positive likelihood ratios were for psychomotor agitation/retardation (1.6) and fatigue (1.7), mostly because of a high rate of false positive results. The highest positive likelihood ratio was found for thoughts of suicide (8.5). The lowest sensitivity, 61.8%, was found for impaired concentration. The sensitivity for worthlessness or guilt in patients with medical illness was 67.2% (95% CI, 57.4-76.9%), which is significantly lower than that found in patients without medical illness, 91.3% (95% CI, 83.2-99.4%). Less adequately identified depressive symptoms were both psychological and somatic in nature. The presence of a medical illness may decrease the sensitivity of recognizing specific depressive symptoms. Programs for training physicians in the use of diagnostic tools should consider their performance in recognizing specific depressive symptoms. Such procedures could allow for the development of specific training to aid in the detection of the most misrecognized depressive symptoms.

  19. Determination of isocyanate specific albumin-adducts in workers exposed to toluene diisocyanates.

    PubMed

    Sabbioni, Gabriele; Gu, Qi; Vanimireddy, Lakshiminiranjan Reddy

    2012-03-01

    Toluene diisocyanates (2,4-TDI and 2,6-TDI) are important intermediates in the chemical industry. Among the main damages after low levels of TDI exposure are lung sensitization and asthma. It is therefore necessary to have sensitive and specific methods to monitor isocyanate exposure of workers. Urinary metabolites or protein adducts have been used as biomarkers in workers exposed to TDI. However, with these methods it was not possible to determine if the biomarkers result from exposure to TDI or to the corresponding toluene diamines (TDA). This work presents a new procedure for the determination of isocyanate-specific albumin adducts. Isotope dilution mass spectrometry was used to measure the adducts in albumin present in workers exposed to TDI. 2,4-TDI and 2,6-TDI formed adducts with lysine: N(ϵ)-[({3-amino-4-methylphenyl}amino)carbonyl]-lysine, N(ϵ)-[({5-amino-2-methylphenyl}amino)carbonyl]-lysine, and N(ϵ)- [({3-amino-2-methylphenyl}amino)carbonyl]-lysine. In future studies, this new method can be applied to measure TDI-exposures in workers.

  20. Comparison of two correlated ROC curves at a given specificity or sensitivity level

    PubMed Central

    Bantis, Leonidas E.; Feng, Ziding

    2017-01-01

    The receiver operating characteristic (ROC) curve is the most popular statistical tool for evaluating the discriminatory capability of a given continuous biomarker. The need to compare two correlated ROC curves arises when individuals are measured with two biomarkers, which induces paired and thus correlated measurements. Many researchers have focused on comparing two correlated ROC curves in terms of the area under the curve (AUC), which summarizes the overall performance of the marker. However, particular values of specificity may be of interest. We focus on comparing two correlated ROC curves at a given specificity level. We propose parametric approaches, transformations to normality, and nonparametric kernel-based approaches. Our methods can be straightforwardly extended for inference in terms of ROC−1(t). This is of particular interest for comparing the accuracy of two correlated biomarkers at a given sensitivity level. Extensions also involve inference for the AUC and accommodating covariates. We evaluate the robustness of our techniques through simulations, compare to other known approaches and present a real data application involving prostate cancer screening. PMID:27324068

  1. Local Atopy in Childhood Adenotonsillar Hypertrophy.

    PubMed

    Cho, Kyu-Sup; Kim, Seong Heon; Hong, Sung-Lyong; Lee, Jaeyoung; Mun, Sue Jean; Roh, Young Eun; Kim, Young Mi; Kim, Hye-Young

    2018-05-01

    Background Although the cause of adenotonsillar hypertrophy remains unknown, some studies have shown that allergy may be a risk factor. Purpose This study determined the levels of allergen-specific immunoglobulin E (sIgE) in the adenotonsillar tissues of children with adenotonsillar hypertrophy and evaluated the clinical significance of local atopy in adenotonsillar tissues. Methods We measured 21 types of specific immunoglobulin E in the serum and adenotonsillar tissues of 102 children with adenotonsillar hypertrophy and compared the sensitization patterns of the serum and local tissues. The patients were divided into three groups-atopy, local atopy, and nonatopy-according to the sensitization of serum and adenotonsillar tissues, and the clinical symptoms among the groups were analyzed. Results Seventy-two (70.6%) children with adenotonsillar hypertrophy were sensitized to more than one allergen in the serum and/or adenotonsillar tissue. Thirty (29.4%) children had no IgE positivity to any allergen in both serum and adenotonsillar tissues. Fifty-five (53.9%) were sensitized to at least one allergen in the serum. Seventy (68.6%) were sensitized to at least one allergen in the adenotonsillar tissue. Seventeen (36.2%) of 47 children with specific immunoglobulin E-negative serum had specific immunoglobulin E-positive adenotonsillar tissues. The rate of specific immunoglobulin E was significantly higher in local tissues than in serum. The rate of inhalant allergen specific immunoglobulin E was significantly higher in the adenoids than in the tonsils. However, the rate of food allergen specific immunoglobulin E was significantly higher in the tonsils than adenoids. The lifetime prevalence of asthma and allergic rhinitis, recent symptoms or treatment of allergic rhinitis, and severity of nasal symptoms (rhinorrhea, sneezing, and nasal itching) were significantly higher in children with local atopy than with nonatopy. Conclusions These results confirm that allergic response may be a risk factor for adenotonsillar hypertrophy. Local allergic inflammation may play an important role in childhood adenotonsillar hypertrophy, and local atopy in adenotonsillar tissues can cause respiratory allergic symptoms in children.

  2. Diagnostic Accuracy of Perioperative Measurement of Basal Anterior Pituitary and Target Gland Hormones in Predicting Adrenal Insufficiency After Pituitary Surgery.

    PubMed

    Cerina, Vatroslav; Kruljac, Ivan; Radosevic, Jelena Marinkovic; Kirigin, Lora Stanka; Stipic, Darko; Pecina, Hrvoje Ivan; Vrkljan, Milan

    2016-03-01

    The insulin tolerance test (ITT) is the gold standard for diagnosing adrenal insufficiency (AI) after pituitary surgery. The ITT is unpleasant for patients, requires close medical supervision and is contraindicated in several comorbidities. The aim of this study was to analyze whether tumor size, remission rate, preoperative, and early postoperative baseline hormone concentrations could serve as predictors of AI in order to increase the diagnostic accuracy of morning serum cortisol. This prospective study enrolled 70 consecutive patients with newly diagnosed pituitary adenomas. Thirty-seven patients had nonfunctioning pituitary adenomas (NPA), 28 had prolactinomas and 5 had somatotropinomas. Thyroxin (T4), thyrotropin (TSH), prolactin, follicle-stimulating hormone (FSH), luteinizing hormone (LH), testosterone, and insulin-like growth factor 1 (IGF-I) were measured preoperatively and on the sixth postoperative day. Serum morning cortisol was measured on the third postoperative day (CORT3) as well as the sixth postoperative day (CORT6). Tumor mass was measured preoperatively and remission was assessed 3 months after surgery. An ITT was performed 3 to 6 months postoperatively. Remission was achieved in 48% of patients and AI occurred in 51%. Remission rates and tumor type were not associated with AI. CORT3 had the best predictive value for AI (area under the curve (AUC) 0.868, sensitivity 82.4%, specificity 83.3%). Tumor size, preoperative T4, postoperative T4, and TSH were also associated with AI in a multivariate regression model. A combination of all preoperative and postoperative variables (excluding serum cortisol) had a sensitivity of 75.0% and specificity of 77.8%. The predictive power of CORT3 substantially improved by adding those variables into the model (AUC 0.921, sensitivity 94.1%, specificity 78.3%, PPV 81.9%, NPV of 92.7%). In a subgroup analysis that included only female patients with NPA, LH had exactly the same predictive value as CORT3. The addition of baseline LH to CORT3, increased sensitivity to 100.0%, specificity to 88.9%, PPV to 90.4%, and NPV to 100.0%. Besides CORT3, tumor size, thyroid hormones, and gonadotropins can serve as predictors of AI. LH in postmenopausal female patients with NPA has similar diagnostic accuracy as CORT3. Further studies are needed in order to validate the scoring system proposed by this study.

  3. The usefulness of “corrected” body mass index vs. self-reported body mass index: comparing the population distributions, sensitivity, specificity, and predictive utility of three correction equations using Canadian population-based data

    PubMed Central

    2014-01-01

    Background National data on body mass index (BMI), computed from self-reported height and weight, is readily available for many populations including the Canadian population. Because self-reported weight is found to be systematically under-reported, it has been proposed that the bias in self-reported BMI can be corrected using equations derived from data sets which include both self-reported and measured height and weight. Such correction equations have been developed and adopted. We aim to evaluate the usefulness (i.e., distributional similarity; sensitivity and specificity; and predictive utility vis-à-vis disease outcomes) of existing and new correction equations in population-based research. Methods The Canadian Community Health Surveys from 2005 and 2008 include both measured and self-reported values of height and weight, which allows for construction and evaluation of correction equations. We focused on adults age 18–65, and compared three correction equations (two correcting weight only, and one correcting BMI) against self-reported and measured BMI. We first compared population distributions of BMI. Second, we compared the sensitivity and specificity of self-reported BMI and corrected BMI against measured BMI. Third, we compared the self-reported and corrected BMI in terms of association with health outcomes using logistic regression. Results All corrections outperformed self-report when estimating the full BMI distribution; the weight-only correction outperformed the BMI-only correction for females in the 23–28 kg/m2 BMI range. In terms of sensitivity/specificity, when estimating obesity prevalence, corrected values of BMI (from any equation) were superior to self-report. In terms of modelling BMI-disease outcome associations, findings were mixed, with no correction proving consistently superior to self-report. Conclusions If researchers are interested in modelling the full population distribution of BMI, or estimating the prevalence of obesity in a population, then a correction of any kind included in this study is recommended. If the researcher is interested in using BMI as a predictor variable for modelling disease, then both self-reported and corrected BMI result in biased estimates of association. PMID:24885210

  4. Seeking a valid gold standard for an innovative, dialect-neutral language test.

    PubMed

    Pearson, Barbara Zurer; Jackson, Janice E; Wu, Haotian

    2014-04-01

    PURPOSE In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. METHOD Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language Variation-Norm Referenced (DELV-NR; Seymour, Roeper, & J. de Villiers, 2005) was administered, and concurrent language samples (LSs) were collected. Using LS profiles as the gold standard, sensitivity, specificity, and other measures of diagnostic accuracy were compared for diagnoses made from the DELV-NR and participants' clinical status prior to recruitment. In a second analysis, the authors used results from the first analysis to make evidence-based adjustments in the estimates of DELV-NR diagnostic accuracy. RESULTS Accuracy of the DELV-NR relative to LS profiles was greater than that of prior diagnoses, indicating that the DELV-NR was an improvement over preexisting diagnoses for this group. Specificity met conventional standards, but sensitivity was somewhat low. Reanalysis using the positive and negative predictive power of the preexisting diagnosis in a discrepant-resolution procedure revealed that estimates for sensitivity and specificity for the DELV-NR were .85 and .93, respectively. CONCLUSION The authors found that, even after making allowances for the imperfection of available gold standards, clinical decisions made with the DELV-NR achieved high values on conventional measures of diagnostic accuracy.

  5. The Ottawa ankle rules for the use of diagnostic X-ray in after hours medical centres in New Zealand.

    PubMed

    Wynn-Thomas, Simon; Love, Tom; McLeod, Deborah; Vernall, Sue; Kljakovic, Marjan; Dowell, Antony; Durham, John

    2002-09-27

    The aims of this study were to measure baseline use of Ottawa ankle rules (OAR), validate the OAR and, if appropriate, explore the impact of implementing the Rules on X-ray rates in a primary care, after hours medical centre setting. General practitioners (GPs) were surveyed to find their awareness of ankle injury guidelines. Data concerning diagnosis and X-ray utilisation were collected prospectively for patients presenting with ankle injuries to two after hours medical centres. The OAR were applied retrospectively, and the sensitivity and specificity of the OAR were compared with GPs clinical judgement in ordering X-rays. The outcome measures were X-ray utilisation and diagnosis of fracture. Awareness of the OAR was low. The sensitivity of the OAR for diagnosis of fractures was 100% (95% CI: 75.3 - 100) and the specificity was 47% (95% CI: 40.5 - 54.5). The sensitivity of GPs clinical judgement was 100% (95% CI: 75.3 - 100) and the specificity was 37% (95% CI: 30.2 - 44.2). Implementing the OAR would reduce X-ray utilisation by 16% (95% CI: approx 10.8 - 21.3). The OAR are valid in a New Zealand primary care setting. Further implementation of the rules would result in some reduction of X-rays ordered for ankle injuries, but less than the reduction found in previous studies.

  6. Probing Ultrafast Electron Dynamics at Surfaces Using Soft X-Ray Transient Reflectivity Spectroscopy

    NASA Astrophysics Data System (ADS)

    Baker, L. Robert; Husek, Jakub; Biswas, Somnath; Cirri, Anthony

    The ability to probe electron dynamics with surface sensitivity on the ultrafast time scale is critical for understanding processes such as charge separation, injection, and surface trapping that mediate efficiency in catalytic and energy conversion materials. Toward this goal, we have developed a high harmonic generation (HHG) light source for femtosecond soft x-ray reflectivity. Using this light source we investigated the ultrafast carrier dynamics at the surface of single crystalline α-Fe2O3, polycrystalline α-Fe2O3, and the mixed metal oxide, CuFeO2. We have recently demonstrated that CuFeO2 in particular is a selective catalyst for photo-electrochemical CO2 reduction to acetate; however, the role of electronic structure and charge carrier dynamics in mediating catalytic selectivity has not been well understood. Soft x-ray reflectivity measurements probe the M2,3, edges of the 3d transition metals, which provide oxidation and spin state resolution with element specificity. In addition to chemical state specificity, these measurements are also surface sensitive, and by independently simulating the contributions of the real and imaginary components of the complex refractive index, we can differentiate between surface and sub-surface contributions to the excited state spectrum. Accordingly, this work demonstrates the ability to probe ultrafast carrier dynamics in catalytic materials with element and chemical state specificity and with surface sensitivity.

  7. Paired comparison of the sensitivity and specificity of multispectral digital skin lesion analysis and reflectance confocal microscopy in the detection of melanoma in vivo: A cross-sectional study.

    PubMed

    Song, Eunice; Grant-Kels, Jane M; Swede, Helen; D'Antonio, Jody L; Lachance, Avery; Dadras, Soheil S; Kristjansson, Arni K; Ferenczi, Katalin; Makkar, Hanspaul S; Rothe, Marti J

    2016-12-01

    Several technologies have been developed to aid dermatologists in the detection of melanoma in vivo including dermoscopy, multispectral digital skin lesion analysis (MDSLA), and reflectance confocal microscopy (RCM). To our knowledge, there have been no studies directly comparing MDSLA and RCM. We conducted a repeated measures analysis comparing the sensitivity and specificity of MDSLA and RCM in the detection of melanoma (n = 55 lesions from 36 patients). Study patients (n = 36) with atypical-appearing pigmented lesions (n = 55) underwent imaging by both RCM and MDSLA. Lesions were biopsied and analyzed by histopathology. RCM exhibited superior test metrics (P = .001, McNemar test) compared with MDSLA. Respectively, sensitivity measures were 85.7% and 71.4%, and specificity rates were 66.7% and 25.0%. The sample size was relatively small and was collected from only one dermatologist's patient base; there was some degree of dermatopathologist interobserver variability; and only one confocalist performed the RCM image evaluations. RCM is a useful adjunct during clinical assessment of in vivo lesions suspicious for melanoma or those requiring re-excision because of high level of dysplasia or having features consistent with an atypical melanocytic nevus with severe cytologic atypia. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Raman spectroscopy and PCA-SVM as a non-invasive diagnostic tool to identify and classify qualitatively glycated hemoglobin levels in vivo.

    PubMed

    Villa-Manríquez, J F; Castro-Ramos, J; Gutiérrez-Delgado, F; Lopéz-Pacheco, M A; Villanueva-Luna, A E

    2017-08-01

    In this study we identify and classify high and low levels of glycated hemoglobin (HbA1c) in healthy volunteers (HV) and diabetic patients (DP). Overall, 86 subjects were evaluated. The Raman spectrum was measured in three anatomical regions of the body: index fingertip, right ear lobe, and forehead. The measurements were performed to compare the difference between the HV and DP (22 well controlled diabetic patients (WCDP) (HbA1c <6.5%), and 49 not controlled diabetic patients (NCDP) (HbA1c ≥6.5%)). Multivariable methods such as principal components analysis (PCA) combined with support vector machine (SVM) were used to develop effective diagnostic algorithms for classification among these groups. The forehead of HV versus WCDP showed the highest sensitivity (100%) and specificity (100%). Sensitivity (100%) and specificity (60%), were highest in the forehead of WCDP, versus NCDP. In HV versus NCDP, the fingertip had the highest sensitivity (100%) and specificity (80%). The efficacy of the diagnostic algorithm by receiver operating characteristic (ROC) curve was confirmed. Overall, our study demonstrated that the combination of Raman spectroscopy and PCA-SVM are feasible non-invasive diagnostic tool in diabetes to classify qualitatively high and low levels of HbA1c in vivo. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Visually assessed colour overlay features in shear-wave elastography for breast masses: quantification and diagnostic performance.

    PubMed

    Gweon, Hye Mi; Youk, Ji Hyun; Son, Eun Ju; Kim, Jeong-Ah

    2013-03-01

    To determine whether colour overlay features can be quantified by the standard deviation (SD) of the elasticity measured in shear-wave elastography (SWE) and to evaluate the diagnostic performance for breast masses. One hundred thirty-three breast lesions in 119 consecutive women who underwent SWE before US-guided core needle biopsy or surgical excision were analysed. SWE colour overlay features were assessed using two different colour overlay pattern classifications. Quantitative SD of the elasticity value was measured with the region of interest including the whole breast lesion. For the four-colour overlay pattern, the area under the ROC curve (Az) was 0.947; with a cutoff point between pattern 2 and 3, sensitivity and specificity were 94.4 % and 81.4 %. According to the homogeneity of the elasticity, the Az was 0.887; with a cutoff point between reasonably homogeneous and heterogeneous, sensitivity and specificity were 86.1 % and 82.5 %. For the SD of the elasticity, the Az was 0.944; with a cutoff point of 12.1, sensitivity and specificity were 88.9 % and 89.7 %. The colour overlay features showed significant correlations with the quantitative SD of the elasticity (P < 0.001). The colour overlay features and the SD of the elasticity in SWE showed excellent diagnostic performance and showed good correlations between them.

  10. Diagnostic accuracy of automatic normalization of CBV in glioma grading using T1- weighted DCE-MRI.

    PubMed

    Sahoo, Prativa; Gupta, Rakesh K; Gupta, Pradeep K; Awasthi, Ashish; Pandey, Chandra M; Gupta, Mudit; Patir, Rana; Vaishya, Sandeep; Ahlawat, Sunita; Saha, Indrajit

    2017-12-01

    Aim of this retrospective study was to compare diagnostic accuracy of proposed automatic normalization method to quantify the relative cerebral blood volume (rCBV) with existing contra-lateral region of interest (ROI) based CBV normalization method for glioma grading using T1-weighted dynamic contrast enhanced MRI (DCE-MRI). Sixty patients with histologically confirmed gliomas were included in this study retrospectively. CBV maps were generated using T1-weighted DCE-MRI and are normalized by contralateral ROI based method (rCBV_contra), unaffected white matter (rCBV_WM) and unaffected gray matter (rCBV_GM), the latter two of these were generated automatically. An expert radiologist with >10years of experience in DCE-MRI and a non-expert with one year experience were used independently to measure rCBVs. Cutoff values for glioma grading were decided from ROC analysis. Agreement of histology with rCBV_WM, rCBV_GM and rCBV_contra respectively was studied using Kappa statistics and intra-class correlation coefficient (ICC). The diagnostic accuracy of glioma grading using the measured rCBV_contra by expert radiologist was found to be high (sensitivity=1.00, specificity=0.96, p<0.001) compared to the non-expert user (sensitivity=0.65, specificity=0.78, p<0.001). On the other hand, both the expert and non-expert user showed similar diagnostic accuracy for automatic rCBV_WM (sensitivity=0.89, specificity=0.87, p=0.001) and rCBV_GM (sensitivity=0.81, specificity=0.78, p=0.001) measures. Further, it was also observed that, contralateral based method by expert user showed highest agreement with histological grading of tumor (kappa=0.96, agreement 98.33%, p<0.001), however; automatic normalization method showed same percentage of agreement for both expert and non-expert user. rCBV_WM showed an agreement of 88.33% (kappa=0.76,p<0.001) with histopathological grading. It was inferred from this study that, in the absence of expert user, automated normalization of CBV using the proposed method could provide better diagnostic accuracy compared to the manual contralateral based approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Ex-vivo whole blood secretion of interferon (IFN)-γ and IFN-γ-inducible protein-10 measured by enzyme-linked immunosorbent assay are as sensitive as IFN-γ enzyme-linked immunospot for the detection of gluten-reactive T cells in human leucocyte antigen (HLA)-DQ2·5+-associated coeliac disease

    PubMed Central

    Ontiveros, N; Tye-Din, J A; Hardy, M Y; Anderson, R P

    2014-01-01

    T cell cytokine release assays are used to diagnose infectious diseases, but not autoimmune or allergic disease. Coeliac disease (CD) is a common T cell-mediated disease diagnosed by the presence of gluten-dependent intestinal inflammation and serology. Many patients cannot be diagnosed with CD because they reduce dietary gluten before medical workup. Oral gluten challenge in CD patients treated with gluten-free diet (GFD) mobilizes gluten-reactive T cells measurable by interferon (IFN)-γ enzyme-linked immunospot (ELISPOT) or major histocompatibility complex (MHC) class II tetramers. Immunodominant peptides are quite consistent in the 90% of patients who possess HLA-DQ2·5. We aimed to develop whole blood assays to detect gluten-specific T cells. Blood was collected before and after gluten challenge from GFD donors confirmed to have CD (n = 27, all HLA-DQ2·5+), GFD donors confirmed not to have CD (n = 6 HLA-DQ2·5+, 11 HLA-DQ2·5−) and donors with CD not following GFD (n = 4, all HLA-DQ2·5+). Plasma IFN-γ and IFN-γ inducible protein-10 (IP-10) were measured by enzyme-linked immunosorbent assay (ELISA) after whole blood incubation with peptides or gliadin, and correlated with IFN-γ ELISPOT. No T cell assay could distinguish between CD patients and controls prior to gluten challenge, but after gluten challenge the whole blood IFN-γ ELISA and the ELISPOT were both 85% sensitive and 100% specific for HLA-DQ2·5+ CD patients; the whole blood IP-10 ELISA was 94% sensitive and 100% specific. We conclude that whole blood cytokine release assays are sensitive and specific for detection of gluten-reactive T cells in CD; further clinical studies addressing the utility of these tests in patients with an uncertain diagnosis of CD is warranted. PMID:24192268

  12. Faces of poverty: sensitivity and specificity of economic classifications in rural Vietnam.

    PubMed

    Khe, Nguyen Duy; Eriksson, Bo; Phuong, Do Nguyen; Höjer, Bengt; Diwan, Vinod K

    2003-01-01

    Poverty concepts and measurements have occupied philosophers for centuries and are subject to debate by researchers. A wide range of possible measures have been developed and used. Most research is country specific and different methods produce different pictures of poverty. This study aimed to compare measures of poverty within an epidemiological field laboratory in Bavi District, northern Vietnam (FilaBavi) and specifically to find out whether the official economic classification made by the local authority matched other measurements of socioeconomic status. Structured questionnaires were used to collect socioeconomic information in 11,547 households. In addition, the official classification for individual households was recorded. Five economic indicators were constructed: income, expenditure, household assets, housing conditions, and local authority's estimation. Official economic classification and housing score were symmetrically distributed, while assets score and particularly income were highly skewed. Design effects were high because of high intra-cluster correlations. No indicator was closely correlated with any other. Sensitivity and positive predictive value for poverty were generally low for all indicators. The authors' findings do not suggest that any of the indicators used is substantially better than the other or better than the Official Economic Classification made by local authority. The results also show that no indicator is particularly useful to predict the values of any other indicator and different poverty indicators may classify different socioeconomic groups as poor.

  13. Novel glucose fiber sensor combining ThFBG with GOD

    NASA Astrophysics Data System (ADS)

    Li, Mengmeng; Zhou, Ciming; Fan, Dian; Ou, Yiwen

    2016-10-01

    We propose a novel glucose fiber optic sensor combining a thinned cladding fiber Bragg grating (ThFBG) with glucose oxidase (GOD). By immobilizing GOD on the surface of a ThFBG, the fabricated sensor can obtain a high specificity to glucose. Because of the evanescent field, the sensor is very sensitive to the ambient refractive index change arising from the catalytic reaction between glucose and GOD. A four-level fiber model was simulated and verified the precision of the sensing principle. Two methods, glutaraldehyde crosslinking method (GCM) and 3-aminopropyl triethoxysilane covalent coupling method (ATCCM), were experimentally utilized to immobilize GOD. And sensor fabricated with the method ATCCM shows a measurement range of 0-0.82 mg/mL which is better than the sensor fabricated with the method GCM with measurement range of 0-0.67 mg/mL under the same condition. By using ATCCM to immobilize GOD with different concentrations, three sensors were fabricated and used for glucose measurement by monitoring the Bragg wavelength (λb) shifts, the results indicate a good linear relationship between wavelength shift and glucose concentration within a specific range, and the measurement range increases as GOD concentration increases. The highest sensitivity of sensor reaches up to 0.0549 nm/(mg.mL-1). The proposed sensor has distinct advantages in sensing structure, cost and specificity.

  14. Comparison of non-invasive measures of cholinergic and allergic airway responsiveness in rats.

    PubMed

    Glaab, T; Hecker, H; Stephan, M; Baelder, R; Braun, A; Korolewitz, R; Krug, N; Hoymann, H G

    2006-04-01

    Non-invasive analysis of tidal expiratory flow parameters such as Tme/TE (time needed to reach peak expiratory flow divided by total expiratory time) or midexpiratory tidal flow (EF50) has been shown useful for phenotypic characterization of lung function in humans and animal models. In this study, we aimed to compare the utility of two non-invasive measures, EF50 and Tme/TE, to monitor bronchoconstriction to inhaled cholinergic and allergic challenges in Brown-Norway rats. Non-invasive measurements of Tme/TE and EF50 were paralleled by invasive recordings of Tme/TE, EF50 and pulmonary conductance (GL). First, dose-response studies with acetylcholine were performed in naive rats, showing that EF50 better than Tme/TE reflected the dose-related changes as observed with the classical invasive outcome parameter GL. The subsequent determination of allergen-specific early airway responsiveness (EAR) showed that ovalbumin-sensitized and -challenged rats exhibited airway inflammation and allergen-specific EAR. Again, EF50 was more sensitive than Tme/TE in detecting the allergen-specific EAR recorded with invasive and non-invasive lung function methods and agreed well with classical GL measurements. We conclude that non-invasive assessment of EF50 is significantly superior to Tme/TE and serves as a suitable and valid tool for phenotypic screening of cholinergic and allergic airway responsiveness in rats.

  15. An evaluation of the DRI-ETG EIA method for the determination of ethyl glucuronide concentrations in clinical and post-mortem urine.

    PubMed

    Turfus, Sophie C; Vo, Tu; Niehaus, Nadia; Gerostamoulos, Dimitri; Beyer, Jochen

    2013-06-01

    A commercial enzyme immunoassay for the qualitative and semi-quantitative measurement of ethyl glucuronide (EtG) in urine was evaluated. Post-mortem (n=800), and clinical urine (n=200) samples were assayed using a Hitachi 902 analyzer. The determined concentrations were compared with those obtained using a previously published liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of EtG and ethyl sulfate. Using a cut-off of 0.5 µg/ml and LC-MS/MS limit of reporting of 0.1 µg/ml, there was a sensitivity of 60.8% and a specificity of 100% for clinical samples. For post-mortem samples, sensitivity and specificity were 82.4% and 97.1%, respectively. When reducing the cut-off to 0.1 µg/ml, the sensitivity and specificity were 83.3% and 100% for clinical samples whereas for post-mortem samples the sensitivity and specificity were 90.3 % and 88.3 %, respectively. The best trade-offs between sensitivity and specificity for LC-MS/MS limits of reporting of 0.5 and 0.1 µg/ml were achieved when using immunoassay cut-offs of 0.3 and 0.092 µg/ml, respectively. There was good correlation between quantitative results obtained by both methods but analysis of samples by LC-MS/MS gave higher concentrations than by enzyme immunoassay (EIA), with a statistically significant proportional bias (P<0.0001, Deming regression) for both sample types. The immunoassay is reliable for the qualitative and semi-quantitative presumptive detection of ethyl glucuronide in urine. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Quantitative Analysis of Swallowing Function Between Dysphagia Patients and Healthy Subjects Using High-Resolution Manometry

    PubMed Central

    2017-01-01

    Objective To compare swallowing function between healthy subjects and patients with pharyngeal dysphagia using high resolution manometry (HRM) and to evaluate the usefulness of HRM for detecting pharyngeal dysphagia. Methods Seventy-five patients with dysphagia and 28 healthy subjects were included in this study. Diagnosis of dysphagia was confirmed by a videofluoroscopy. HRM was performed to measure pressure and timing information at the velopharynx (VP), tongue base (TB), and upper esophageal sphincter (UES). HRM parameters were compared between dysphagia and healthy groups. Optimal threshold values of significant HRM parameters for dysphagia were determined. Results VP maximal pressure, TB maximal pressure, UES relaxation duration, and UES resting pressure were lower in the dysphagia group than those in healthy group. UES minimal pressure was higher in dysphagia group than in the healthy group. Receiver operating characteristic (ROC) analyses were conducted to validate optimal threshold values for significant HRM parameters to identify patients with pharyngeal dysphagia. With maximal VP pressure at a threshold value of 144.0 mmHg, dysphagia was identified with 96.4% sensitivity and 74.7% specificity. With maximal TB pressure at a threshold value of 158.0 mmHg, dysphagia was identified with 96.4% sensitivity and 77.3% specificity. At a threshold value of 2.0 mmHg for UES minimal pressure, dysphagia was diagnosed at 74.7% sensitivity and 60.7% specificity. Lastly, UES relaxation duration of <0.58 seconds had 85.7% sensitivity and 65.3% specificity, and UES resting pressure of <75.0 mmHg had 89.3% sensitivity and 90.7% specificity for identifying dysphagia. Conclusion We present evidence that HRM could be a useful evaluation tool for detecting pharyngeal dysphagia. PMID:29201816

  17. [Rapid identification of potato cultivars using NIR-excited fluorescence and Raman spectroscopy].

    PubMed

    Dai, Fen; Bergholt, Mads Sylvest; Benjamin, Arnold Julian Vinoj; Hong, Tian-Sheng; Zhiwei, Huang

    2014-03-01

    Potato is one of the most important food in the world. Rapid and noninvasive identification of potato cultivars plays a important role in the better use of varieties. In this study, The identification ability of optical spectroscopy techniques, including near-infrared (NIR) Raman spectroscopy and NIR fluorescence spectroscopy, for invasive detection of potato cultivars was evaluated. A rapid NIR Raman spectroscopy system was applied to measure the composite Raman and NIR fluorescence spectroscopy of 3 different species of potatoes (98 samples in total) under 785 nm laser light excitation. Then pure Raman and NIR fluorescence spectroscopy were abstracted from the composite spectroscopy, respectively. At last, the partial least squares-discriminant analysis (PLS-DA) was utilized to analyze and classify Raman spectra of 3 different types of potatoes. All the samples were divided into two sets at random: the calibration set (74samples) and prediction set (24 samples), the model was validated using a leave-one-out, cross-validation method. The results showed that both the NIR-excited fluorescence spectra and pure Raman spectra could be used to identify three cultivars of potatoes. The fluorescence spectrum could distinguish the Favorita variety well (sensitivity: 1, specificity: 0.86 and accuracy: 0.92), but the result for Diamant (sensitivity: 0.75, specificity: 0.75 and accuracy: 0. 75) and Granola (sensitivity: 0.16, specificity: 0.89 and accuracy: 0.71) cultivars identification were a bit poorer. We demonstrated that Raman spectroscopy uncovered the main biochemical compositions contained in potato species, and provided a better classification sensitivity, specificity and accuracy (sensitivity: 1, specificity: 1 and accuracy: 1 for all 3 potato cultivars identification) among the three types of potatoes as compared to fluorescence spectroscopy.

  18. Quantitative Analysis of Swallowing Function Between Dysphagia Patients and Healthy Subjects Using High-Resolution Manometry.

    PubMed

    Park, Chul-Hyun; Kim, Don-Kyu; Lee, Yong-Taek; Yi, Youbin; Lee, Jung-Sang; Kim, Kunwoo; Park, Jung Ho; Yoon, Kyung Jae

    2017-10-01

    To compare swallowing function between healthy subjects and patients with pharyngeal dysphagia using high resolution manometry (HRM) and to evaluate the usefulness of HRM for detecting pharyngeal dysphagia. Seventy-five patients with dysphagia and 28 healthy subjects were included in this study. Diagnosis of dysphagia was confirmed by a videofluoroscopy. HRM was performed to measure pressure and timing information at the velopharynx (VP), tongue base (TB), and upper esophageal sphincter (UES). HRM parameters were compared between dysphagia and healthy groups. Optimal threshold values of significant HRM parameters for dysphagia were determined. VP maximal pressure, TB maximal pressure, UES relaxation duration, and UES resting pressure were lower in the dysphagia group than those in healthy group. UES minimal pressure was higher in dysphagia group than in the healthy group. Receiver operating characteristic (ROC) analyses were conducted to validate optimal threshold values for significant HRM parameters to identify patients with pharyngeal dysphagia. With maximal VP pressure at a threshold value of 144.0 mmHg, dysphagia was identified with 96.4% sensitivity and 74.7% specificity. With maximal TB pressure at a threshold value of 158.0 mmHg, dysphagia was identified with 96.4% sensitivity and 77.3% specificity. At a threshold value of 2.0 mmHg for UES minimal pressure, dysphagia was diagnosed at 74.7% sensitivity and 60.7% specificity. Lastly, UES relaxation duration of <0.58 seconds had 85.7% sensitivity and 65.3% specificity, and UES resting pressure of <75.0 mmHg had 89.3% sensitivity and 90.7% specificity for identifying dysphagia. We present evidence that HRM could be a useful evaluation tool for detecting pharyngeal dysphagia.

  19. Is it possible to shorten ambulatory blood pressure monitoring?

    PubMed

    Wolak, Talya; Wilk, Lior; Paran, Esther; Wolak, Arik; Gutmacher, Bella; Shleyfer, Elena; Friger, Michael

    2013-08-01

    The aim of this investigation was to find a time segment in which average blood pressure (BP) has the best correlation with 24-hour BP control. A total of 240 patients with full ambulatory BP monitoring (ABPM) were included; 120 had controlled BP (systolic BP [SBP] ≤135 mm Hg and diastolic BP [DBP] ≤85 mm Hg) and 120 had uncontrolled BP (SBP >135 mm Hg and/or DBP >85 mm Hg). Each ABPM was divided into 6- and 8-hour segments. Evaluation for correlation between mean BP for each time segment and 24-hour BP control was performed using receiver operating characteristic curve analysis and Youden's index for threshold with the best sensitivity and specificity. The mean BP in the following segments showed the highest area under the curve (AUC) compared with average controlled 24-hour BP: SBP 2 am to 8 am (AUC, 0.918; threshold value of 133.5 mm Hg, sensitivity-0.752 and specificity-0.904); SBP 2 pm to 10 pm (AUC, 0.911; threshold value of 138.5 mm Hg, sensitivity-0.803 and specificity-0.878); and SBP 6 am to 2 pm (AUC, 0.903; threshold value of 140.5 mm Hg, sensitivity-0.778 and specificity-0.888). The time segment 2 pm to 10 pm was shown to have good correlation with 24-hour BP control (AUC >0.9; sensitivity and specificity >80%). This time segment might replace full ABPM as a screening measure for BP control or as abbreviated ABPM for patients with difficulty in performing full ABPM. © 2013 Wiley Periodicals, Inc.

  20. Diagnostic value of serum Golgi protein 73 for HBV-related primary hepatic carcinoma

    PubMed Central

    Gao, Guosheng; Dong, Feibo; Xu, Xiaozhen; Hu, Airong; Hu, Yaoren

    2015-01-01

    Background: Alpha-fetoprotein (AFP) levels are routinely used for diagnosis and monitoring of hepatic diseases, but it has a limited value. Golgi protein 73 (GP73) has been suggested as a new marker for hepatic diseases. Objective: To explore the clinical value of serum GP73 in different diseases associated with hepatitis B virus (HBV) infection. Method: Between January 2010 and August 2014, serum samples from 88 patients with chronic hepatitis B (CHB), 78 patients with HBV-related liver cirrhosis (LC), and 194 patients with HBV-related primary hepatic cancer (PHC) were collected. Serum samples from 30 healthy volunteers were used as controls. ELISA and microparticle enzyme immunoassay were used to measure serum GP73 and AFP levels. Receiver operating characteristic (ROC) curves were used to analyze the diagnostic value of serum GP73 and AFP for PHC. Results: For the diagnosis of PHC, GP73 showed a sensitivity of 65.5% and specificity of 66.3%, while AFP levels showed sensitivity of 64.4% and specificity of 76.5%. Serial testing (both tests are positive) could increase the specificity (sensitivity of 45.9% and specificity of 85.5%) while parallel testing (any single positive test result) could increase the sensitivity (sensitivity of 84.0% and specificity of 57.2%). Serum GP73 and AFP levels were significantly different between Child-Pugh grades (P<0.001 for GP73 and P=0.044 for AFP). Significant differences in serum GP73 and AFP were found between TNM stages (all P<0.001). Conclusion: Serum GP73 had limited diagnostic value for HBV-related PHC. The combined use of serum GP73 and AFP levels improved the diagnostic efficacy. PMID:26617863

  1. Preoperative identification of a suspicious adnexal mass: a systematic review and meta-analysis.

    PubMed

    Dodge, Jason E; Covens, Allan L; Lacchetti, Christina; Elit, Laurie M; Le, Tien; Devries-Aboud, Michaela; Fung-Kee-Fung, Michael

    2012-07-01

    To systematically review the existing literature in order to determine the optimal strategy for preoperative identification of the adnexal mass suspicious for ovarian cancer. A review of all systematic reviews and guidelines published between 1999 and 2009 was conducted as a first step. After the identification of a 2004 AHRQ systematic review on the topic, searches of MEDLINE for studies published since 2004 was also conducted to update and supplement the evidentiary base. A bivariate, random-effects meta-regression model was used to produce summary estimates of sensitivity and specificity and to plot summary ROC curves with 95% confidence regions. Four meta-analyses and 53 primary studies were included in this review. The diagnostic performance of each technology was compared and contrasted based on the summary data on sensitivity and specificity obtained from the meta-analysis. Results suggest that 3D ultrasonography has both a higher sensitivity and specificity when compared to 2D ultrasound. Established morphological scoring systems also performed with respectable sensitivity and specificity, each with equivalent diagnostic competence. Explicit scoring systems did not perform as well as other diagnostic testing methods. Assessment of an adnexal mass by colour Doppler technology was neither as sensitive nor as specific as simple ultrasonography. Of the three imaging modalities considered, MRI appeared to perform the best, although results were not statistically different from CT. PET did not perform as well as either MRI or CT. The measurement of the CA-125 tumour marker appears to be less reliable than do other available assessment methods. The best available evidence was collected and included in this rigorous systematic review and meta-analysis. The abundant evidentiary base provided the context and direction for the diagnosis of early-staged ovarian cancer. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Laboratory variables for assessing iron deficiency in REDS-II Iron Status Evaluation (RISE) blood donors

    PubMed Central

    Kiss, Joseph E.; Steele, Whitney R.; Wright, David J.; Mast, Alan E.; Carey, Patricia M.; Murphy, Edward L.; Gottschall, Jerry L.; Simon, Toby L.; Cable, Ritchard G.

    2014-01-01

    BACKGROUND Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management. STUDY DESIGN AND METHODS A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study-II (REDS-II) Donor Iron Status Evaluation (RISE) study who were either first-time/reactivated (FT/ RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 µ.g/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron-deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE. RESULTS HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 u.g/L was a good surrogate for assessing IDE. CONCLUSION RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency. PMID:23617531

  3. Value of parents' estimates of children's developmental ages.

    PubMed

    Glascoe, F P; Sandler, H

    1995-11-01

    To determine whether parents' estimates of children's developmental ages can function as a prescreening technique. Parents of 234 children from birth to 77 months of age seeking well-child care in pediatric offices were queried in two separate studies. In the first study, parents were asked to give an estimate of their child's overall developmental age and, in the second study, to estimate ages in each of six developmental domains. Children were administered a range of screening measures of intelligence, speech-language, and adoptive behavior. The overall age-estimate, if less than chronologic age, was 75% sensitive to likely developmental problems and, if equal to or greater than chronologic age, was 90% specific in identifying children likely to have typical development. Age estimates for each developmental domain were 81% sensitive to likely developmental problems if less than chronologic age in the domains of fine motor, language, grass motor, or behavior, and 62% specific if equal to or greater than chronologic age. Estimates at or below chronologic age in receptive language or personal-social domains were 90% sensitive and 43% specific in identifying likely behavior problems. There were no differences in the accuracy of parents estimates on the basis of children's age, gender, race, parents' level of education, or parenting experience. Parents' overall age-estimates provided a sensitive and specific indicator of global developmental status, but insufficient information about strengths and weaknesses to enable focused referrals for services. In contrast, discrete patterns of age estimates in each developmental domain sensitively discriminated children with developmental versus behavioral problems, although specificity was limited. Age estimates appear to be a potentially helpful method for identifying a subset of children in need of thorough screening, although further research is needed on a larger sample given diagnostic rather than screening tests.

  4. Laboratory variables for assessing iron deficiency in REDS-II Iron Status Evaluation (RISE) blood donors.

    PubMed

    Kiss, Joseph E; Steele, Whitney R; Wright, David J; Mast, Alan E; Carey, Patricia M; Murphy, Edward L; Gottschall, Jerry L; Simon, Toby L; Cable, Ritchard G

    2013-11-01

    Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management. A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study-II (REDS-II) Donor Iron Status Evaluation (RISE) study who were either first-time/reactivated (FT/RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 μg/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron-deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE. HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 μg/L was a good surrogate for assessing IDE. RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency. © 2013 American Association of Blood Banks.

  5. Diagnostic value of sleep stage dissociation as visualized on a 2-dimensional sleep state space in human narcolepsy.

    PubMed

    Olsen, Anders Vinther; Stephansen, Jens; Leary, Eileen; Peppard, Paul E; Sheungshul, Hong; Jennum, Poul Jørgen; Sorensen, Helge; Mignot, Emmanuel

    2017-04-15

    Type 1 narcolepsy (NT1) is characterized by symptoms believed to represent Rapid Eye Movement (REM) sleep stage dissociations, occurrences where features of wake and REM sleep are intermingled, resulting in a mixed state. We hypothesized that sleep stage dissociations can be objectively detected through the analysis of nocturnal Polysomnography (PSG) data, and that those affecting REM sleep can be used as a diagnostic feature for narcolepsy. A Linear Discriminant Analysis (LDA) model using 38 features extracted from EOG, EMG and EEG was used in control subjects to select features differentiating wake, stage N1, N2, N3 and REM sleep. Sleep stage differentiation was next represented in a 2D projection. Features characteristic of sleep stage differences were estimated from the residual sleep stage probability in the 2D space. Using this model we evaluated PSG data from NT1 and non-narcoleptic subjects. An LDA classifier was used to determine the best separation plane. This method replicates the specificity/sensitivity from the training set to the validation set better than many other methods. Eight prominent features could differentiate narcolepsy and controls in the validation dataset. Using a composite measure and a specificity cut off 95% in the training dataset, sensitivity was 43%. Specificity/sensitivity was 94%/38% in the validation set. Using hypersomnia subjects, specificity/sensitivity was 84%/15%. Analyzing treated narcoleptics the specificity/sensitivity was 94%/10%. Sleep stage dissociation can be used for the diagnosis of narcolepsy. However the use of some medications and presence of undiagnosed hypersomnolence patients impacts the result. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Posturography and locomotor tests of dynamic balance after long-duration spaceflight.

    PubMed

    Cohen, Helen S; Kimball, Kay T; Mulavara, Ajitkumar P; Bloomberg, Jacob J; Paloski, William H

    2012-01-01

    The currently approved objective clinical measure of standing balance in astronauts after space flight is the Sensory Organization Test battery of computerized dynamic posturography. No tests of walking balance are currently approved for standard clinical testing of astronauts. This study determined the sensitivity and specificity of standing and walking balance tests for astronauts before and after long-duration space flight. Astronauts were tested on an obstacle avoidance test known as the Functional Mobility Test (FMT) and on the Sensory Organization Test using sway-referenced support surface motion with eyes closed (SOT 5) before and six months after (n=15) space flight on the International Space Station. They were tested two to seven days after landing. Scores on SOT tests decreased and scores on FMT increased significantly from pre- to post-flight. In other words, post-flight scores were worse than pre-flight scores. SOT and FMT scores were not significantly related. ROC analyses indicated supra-clinical cut-points for SOT 5 and for FMT. The standard clinical cut-point for SOT 5 had low sensitivity to post-flight astronauts. Higher cut-points increased sensitivity to post-flight astronauts but decreased specificity to pre-flight astronauts. Using an FMT cut-point that was moderately highly sensitive and highly specific plus SOT 5 at the standard clinical cut-point was no more sensitive than SOT 5, alone. FMT plus SOT 5 at higher cut-points was more specific and more sensitive. The total correctly classified was highest for FMT, alone, and for FMT plus SOT 5 at the highest cut-point. These findings indicate that standard clinical comparisons are not useful for identifying problems. Testing both standing and walking balance will be more likely to identify balance deficits.

  7. Identifying Moderators of the Link between Parent and Child Anxiety Sensitivity: The Roles of Gender, Positive Parenting, and Corporal Punishment

    PubMed Central

    Graham, Rebecca A.; Weems, Carl F.

    2014-01-01

    A substantial body of literature suggests that anxiety sensitivity is a risk factor for the development of anxiety problems and research has now begun to examine the links between parenting, parent anxiety sensitivity and their child’s anxiety sensitivity. However, the extant literature has provided mixed findings as to whether parent anxiety sensitivity is associated with child anxiety sensitivity, with some evidence suggesting that others factors may influence the association. Theoretically, specific parenting behaviors may be important to the development of child anxiety sensitivity and also in understanding the association between parent and child anxiety sensitivity. In this study, 191 families (n = 255 children and adolescents aged 6–17 and their parents) completed measures of child anxiety sensitivity (CASI) and parenting (APQ-C), and parents completed measures of their own anxiety sensitivity (ASI) and their parenting (APQ-P). Corporal punishment was associated with child anxiety sensitivity and the child’s report of their parent’s positive parenting behaviors moderated the association between parent and child anxiety sensitivity. The child’s gender was also found to moderate the association between parent and child anxiety sensitivity, such that there was a positive association between girls and parent anxiety sensitivity and a negative association in boys. The findings advance the understanding of child anxiety sensitivity by establishing a link with corporal punishment and by showing that the association between parent and child anxiety sensitivity may depend upon the parenting context and child’s gender. PMID:25301177

  8. Diagnostic Accuracy of the FIGO and the 5-Tier Fetal Heart Rate Classification Systems in the Detection of Neonatal Acidemia.

    PubMed

    Martí Gamboa, Sabina; Giménez, Olga Redrado; Mancho, Jara Pascual; Moros, María Lapresta; Sada, Julia Ruiz; Mateo, Sergio Castan

    2017-04-01

    Objective  The objective of this study was to determine ability to detect neonatal acidemia and interobserver agreement with the FIGO 3-tier and 5-tier fetal heart rate (FHR) classification systems. Design  This was a case-control study. Setting  This study was set at the University Medical Center. Population  A total of 202 FHR tracings of 102 women who delivered an acidemic fetus (umbilical arterial cord gas pH ≤ 7.10 and BE < - 8) and 100 who delivered a nonacidemic fetus (umbilical arterial cord gas pH > 7.10) were assessed. A subanalysis was performed for those fetuses who suffered severe metabolic acidemia (pH ≤ 7.0 and BE < - 12). Methods  Two reviewers blind to clinical and outcome data classified tracings according to the new 3-tier system proposed by the FIGO and the 5-tier system proposed by Parer and Ikeda. Main Outcome Measures  Sensitivity and specificity for detecting neonatal acidemia and interobserver agreement in classifying FHR tracings into categories of both systems were studied. Results  The 3-tier system showed a greater sensitivity and lower specificity to detect neonatal acidemia (43.6% sensitivity, 82.5% specificity) and severe metabolic acidemia (71.4% sensitivity, 74.0% specificity) compared with the 5-tier system (36.3% sensitivity, 88% specificity and 61.9% sensitivity, 80.1% specificity, respectively). Both systems were compared by area under the receiver-operating characteristic curve, with comparable predictive ability for detecting neonatal acidemia (FIGO-area under the curve [AUC]: 0.63 [95% confidence interval [CI]: 0.57-0.68] and Parer-AUC: 0.62 [95% CI: 0.56-0.67]). Interobserver agreement was moderate for both systems, but performance at each specific category showed a better agreement for the 5-tier system identifying a pathological tracing (orange or red, κ: 0.625 vs. pathological category, κ: 0.538). Conclusion  Both systems presented a comparable ability to predict neonatal acidemia, although the 5-tier system showed a better interobserver agreement identifying pathological tracings. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Measurement of 37Ar to support technology for On-site Inspection under the Comprehensive Nuclear-Test-Ban Treaty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aalseth, Craig E.; Day, Anthony R.; Haas, Derek A.

    On-Site Inspection (OSI) is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclide isotopes created by an underground nuclear explosion are a valuable signature of a Treaty violation. Argon-37 is produced from neutron interaction with calcium in soil, 40Ca(n,α)37Ar. For OSI, the 35-day half-life of 37Ar provides both high specific activity and sufficient time for completion of an inspection before decay limits sensitivity. This paper presents a low-background internal-source gas proportional counter with an 37Ar measurement sensitivity level equivalent to 45.1 mBq/SCM in whole air.

  10. IMRT QA: Selecting gamma criteria based on error detection sensitivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steers, Jennifer M.; Fraass, Benedick A., E-mail: benedick.fraass@cshs.org

    Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique,more » and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose threshold was consistent across all studied combinations of %Diff/DTA. Criteria such as 2%/3 mm and 3%/2 mm with a 50% threshold at 90% pixels passing are shown to be more appropriately sensitive without being overly strict. However, a broadening of the penumbra by as much as 5 mm in the beam configuration was difficult to detect with commonly used criteria, as well as with the previously mentioned criteria utilizing a threshold of 50%. Conclusions: We have introduced the error curve method, an analysis technique which allows the quantitative determination of gamma criteria sensitivity to induced errors. The application of the error curve method using DMLC IMRT plans measured on the ArcCHECK® device demonstrated that large errors can potentially be missed in IMRT QA with commonly used gamma criteria (e.g., 3%/3 mm, threshold = 10%, 90% pixels passing). Additionally, increasing the dose threshold value can offer dramatic increases in error sensitivity. This approach may allow the selection of more meaningful gamma criteria for IMRT QA and is straightforward to apply to other combinations of devices and treatment techniques.« less

  11. Improved sensitivity to venom specific-immunoglobulin E by spiking with the allergen component in Japanese patients suspected of Hymenoptera venom allergy.

    PubMed

    Yoshida, Naruo; Hirata, Hirokuni; Watanabe, Mineaki; Sugiyama, Kumiya; Arima, Masafumi; Fukushima, Yasutsugu; Ishii, Yoshiki

    2015-07-01

    Ves v 5 and Pol d 5, which constitute antigen 5, are recognized as the major, most potent allergens of family Vespidae. Several studies have reported the diagnostic sensitivity of the novel recombinant (r)Ves v 5 and rPol d 5 allergens in routine clinical laboratory settings by analyzing a group of Vespula and Polistes venom-allergic patients. In this study, we analyzed the sensitivity to venom specific (s)IgE by spiking with rVes v 5 and rPol d 5 in Japanese patients suspected of Hymenoptera venom allergy. Subjects were 41 patients who had experienced systemic reactions to hornet and/or paper wasp stings. Levels of serum sIgE against hornet and paper wasp venom by spiking with rVes v 5 and rPold d 5, respectively, as improvement testing, compared with hornet and paper wasp venom, as conventional testing, were measured by ImmunoCAP. Of the 41 patients, 33 (80.5%) were positive (≥0.35 UA/ml) for hornet and/or paper wasp venom in conventional sIgE testing. sIgE levels correlated significantly (P < 0.01) between hornet (R = 0.92) or paper wasp venom (R = 0.78) in improvement testing and conventional testing. To determine specificity, 20 volunteers who had never experienced a Hymenoptera sting were all negative for sIgE against these venoms in both improvement and conventional testing. Improved sensitivity was seen in 8 patients negative for sIgE against both venoms in conventional testing, while improvement testing revealed sIgE against hornet or paper wasp venom in 5 (total 38 (92.7%)) patients. The measurement of sIgE following spiking of rVes v 5 and rPol d 5 by conventional testing in Japanese subjects with sIgE against hornet and paper wasp venom, respectively, improved the sensitivity for detecting Hymenoptera venom allergy. Improvement testing for measuring sIgE levels against hornet and paper wasp venom has potential for serologically elucidating Hymenoptera allergy in Japan. Copyright © 2015 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.

  12. Single-energy non-contrast hepatic steatosis criteria applied to virtual non-contrast images: is it still highly specific and positively predictive?

    PubMed

    Haji-Momenian, S; Parkinson, W; Khati, N; Brindle, K; Earls, J; Zeman, R K

    2018-06-01

    To determine the sensitivity, specificity, and predictive values of single-energy non-contrast hepatic steatosis criteria on dual-energy virtual non-contrast (VNC) images. Forty-eight computed tomography (CT) examinations, which included single-energy non-contrast (TNC) and contrast-enhanced dual-energy CT angiography (CTA) of the abdomen, were enrolled. VNC images were reconstructed from the CTA. Region of interest (ROI) attenuations were measured in the right and left hepatic lobes, spleen, and aorta on TNC and VNC images. The right and left hepatic lobes were treated as separate samples. Steatosis was diagnosed based on TNC liver attenuation of ≤40 HU or liver attenuation index (LAI) of ≤-10 HU, which are extremely specific and predictive for moderate to severe steatosis. The sensitivity, specificity, and predictive values of VNC images for steatosis were calculated. VNC-TNC deviations were correlated with aortic enhancement and patient water equivalent diameter (PWED). Thirty-two liver ROIs met steatosis criteria based on TNC attenuation; VNC attenuation had sensitivity, specificity, and a positive predictive value of 66.7%, 100%, and 100%, respectively. Twenty-one liver ROIs met steatosis criteria based on TNC LAI. VNC LAI had sensitivity, specificity, and positive predictive values of 61.9%, 90.7%, and 65%, respectively. Hepatic and splenic VNC-TNC deviations did not correlate with one another (R 2 =0.08), aortic enhancement (R 2 <0.06) or PWED (R 2 <0.09). Non-contrast hepatic attenuation criteria is extremely specific and positively predictive for moderate to severe steatosis on VNC reconstructions from the arterial phase. Hepatic attenuation performs better than LAI criteria. VNC deviations are independent of aortic enhancement and PWED. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Highly specific preoperative selection of solitary parathyroid adenoma cases in primary hyperparathyroidism by quantitative image analysis of the early-phase Technetium-99m sestamibi scan.

    PubMed

    Kim, DaeHee; Rhodes, Jeffrey A; Hashim, Jeffrey A; Rickabaugh, Lawrence; Brams, David M; Pinkus, Edward; Dou, Yamin

    2018-06-07

    Highly specific preoperative localizing test is required to select patients for minimally invasive parathyroidectomy (MIP) in lieu of traditional four-gland exploration. We hypothesized that Tc-99m sestamibi scan interpretation incorporating numerical measurements on the degree of asymmetrical activity from bilateral thyroid beds can be useful in localizing single adenoma for MIP. We devised a quantitative interpretation method for Tc-99m sestamibi scan based on the numerically graded asymmetrical activity on early phase. The numerical ratio value of each scan was obtained by dividing the number of counts from symmetrically drawn regions of interest (ROI) over bilateral thyroid beds. The final pathology and clinical outcome of 109 patients were used to perform receiver operating curve (ROC) analysis. Receiver operating curve analysis revealed the area under the curve (AUC) was calculated to be 0.71 (P = 0.0032), validating this method as a diagnostic tool. The optimal cut-off point for the ratio value with maximal combined sensitivity and specificity was found with corresponding sensitivity of 67.9% (56.5-77.2%, 95% CI) and specificity of 75.0% (52.8-91.8%, 95% CI). An additional higher cut-off with higher specificity with minimal possible sacrifice on sensitivity was also selected, yielding sensitivity of 28.6% (18.8-38.6%, 95% CI) and specificity of 90.0% (69.6-98.8%, 95% CI). Our results demonstrated that the more asymmetrical activity on the initial phase, the more successful it is to localize a single parathyroid adenoma on sestamibi scans. Using early-phase Tc-99m sestamibi scan only, we were able to select patients for minimally invasive parathyroidectomy with 90% specificity. © 2018 The Royal Australian and New Zealand College of Radiologists.

  14. Gas sensitive materials for gas detection and method of making

    DOEpatents

    Trakhtenberg, Leonid Israilevich; Gerasimov, Genrikh Nikolaevich; Gromov, Vladimir Fedorovich; Rozenberg, Valeriya Isaakovna

    2012-12-25

    A gas sensitive material comprising SnO2 nanocrystals doped with In2O3 and an oxide of a platinum group metal, and a method of making the same. The platinum group metal is preferably Pd, but also may include Pt, Ru, Ir, and combinations thereof. The SnO2 nanocrystals have a specific surface of 7 or greater, preferably about 20 m2/g, and a mean particle size of between about 10 nm and about 100 nm, preferably about 40 nm. A gas detection device made from the gas sensitive material deposited on a substrate, the gas sensitive material configured as a part of a current measuring circuit in communication with a heat source.

  15. Integrated Arrays of Ion-Sensitive Electrodes

    NASA Technical Reports Server (NTRS)

    Buehler, Martin; Kuhlman, Kimberly

    2003-01-01

    The figure depicts an example of proposed compact water-quality sensors that would contain integrated arrays of ion-sensitive electrodes (ISEs). These sensors would serve as electronic "tongues": they would be placed in contact with water and used to "taste" selected dissolved ions (that is, they would be used to measure the concentrations of the ions). The selected ions could be any or all of a variety of organic and inorganic cations and anions that could be regarded as contaminants or analytes, depending on the specific application. In addition, some of the ISEs could be made sensitive to some neutral analytes

  16. Testing Hippocampal Memory in Prodromal Dementia with Lewy Bodies.

    PubMed

    Bussè, Cinzia; Caffarra, Paolo; Rossi, Alice; Zorzi, Giovanni; Fragiacomo, Federica; Camporese, Giulia; Pompanin, Sara; Di Bernardo, Gian Antonio; Cagnin, Annachiara

    2018-01-01

    The Free and Cued Selective Reminding test (FCSRT) was used to assess memory in 19 patients with prodromal dementia with Lewy bodies (DLB) and 25 Alzheimer's disease (AD) patients. DLB scored better than AD in selective measures of the FCSRT: immediate total recall (p = 0.01) and index of sensitivity of cueing (p = 0.001), while free delayed and total memory scores were similarly impaired. The index of sensitivity of cueing held a sensitivity of 76% and specificity of 79% in distinguishing DLB. FCSRT could help in disentangling hippocampal memory deficits from memory impairment due to ineffective recall strategies.

  17. Agreement between ethnicity recorded in two New Zealand health databases: effects of discordance on cardiovascular outcome measures (PREDICT CVD3).

    PubMed

    Marshall, Roger J; Zhang, Zhongqian; Broad, Joanna B; Wells, Sue

    2007-06-01

    To assess agreement between ethnicity as recorded by two independent databases in New Zealand, PREDICT and the National Health Index (NHI), and to assess sensitivity of ethnic-specific measures of health outcomes to either ethnicity record. Patients assessed using PREDICT form the study cohort. Ethnicity was recorded for PREDICT and an associated NHI ethnicity code was identified by merge-match linking on an encrypted NHI number. Agreement between ethnicity measures was assessed by kappa scores and scaled rectangle diagrams. A cohort of 18,239 individuals was linked in both PREDICT and NHI databases. The agreement between ethnicity classifications was reasonably good, with overall kappa coefficient of 0.82. There was better agreement for women than men and agreement improved with age and with time since the PREDICT system has been operational. Ethnic-specific cardiovascular (CVD) hospital admission rates were sensitive to ethnicity coding by NHI or PREDICT; rate ratios for ethnic groups, relative to European, based on PREDICT were attenuated towards the null relative to the NHI classification. Agreement between ethnicity was moderately good. Discordances that do exist do not have a substantial effect on prevalence-based measures of effect; however, they do on measurement of the admission of CVD. Different categorisations of ethnicity data from routine (and other) databases can lead to different ethnic-specific estimates of epidemiological effects. There is an imperative to record ethnicity in a rational, systematic and consistent way.

  18. Detection of PCT and urinary β2 -MG enhances the accuracy for localization diagnosing pediatric urinary tract infection.

    PubMed

    Fang, Jian; Luan, Jiangwei; Zhu, Gaohong; Qi, Chang; Wang, Dandan

    2017-09-01

    The purpose of this article was to investigate whether the combination of urinary beta 2 microglobulin (urinary β 2 -MG) and procalcitonin (PCT) diagnosis could enhance the localization diagnostic precision of pediatric urinary tract infection comparing with single diagnosis. A study was conducted in the Nephrology Department of Wuhan women and children's health care centre. This study incorporated 85 participants, including 35 children who were diagnosed as upper urinary tract infection (UUTI) with the symptom of fever and 50 children who conducted lower urinary tract infection (LUTI). Levels of PCT and urinary β 2 -MG in both UUTI and LUTI patients were measured and compared. The level of PCT and β 2 -MG were both significantly higher in UUTI group compared with in LUTI group. AUC of urinary β 2 -MG ROC (sensitivity of 71.4%, specificity of 90.0%) was significantly smaller than that of PCT ROC (sensitivity of 77.1%, specificity of 96.0%) in the single diagnosis. Although in the combined diagnosis, the sensitivity and specificity increased to 88.6% and 98%, respectively. Both PCT and β 2 -MG could be used to localize the UTI. Introducing urinary β 2 -MG into PCT diagnosis could increase the sensitivity and specificity of UTI lesion diagnosis in clinical practice. © 2016 The Authors Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.

  19. Vestibular (dys)function in children with sensorineural hearing loss: a systematic review.

    PubMed

    Verbecque, Evi; Marijnissen, Tessa; De Belder, Niels; Van Rompaey, Vincent; Boudewyns, An; Van de Heyning, Paul; Vereeck, Luc; Hallemans, Ann

    2017-06-01

    The objective of this study is to provide an overview of the prevalence of vestibular dysfunction in children with SNHL classified according to the applied test and its corresponding sensitivity and specificity. Data were gathered using a systematic search query including reference screening. Pubmed, Web of Science and Embase were searched. Strategy and reporting of this review was based on the Meta-analysis of Observational Studies in Epidemiology (MOOSE) guidelines. Methodological quality was assessed with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. All studies, regardless the applied vestibular test, showed that vestibular function differs significantly between children with hearing loss and normal hearing (p < 0.05). Compared with caloric testing, the sensitivity of the Rotational Chair Test (RCT) varies between 61 and 80% and specificity between 21 and 80%, whereas this was, respectively, 71-100% and 30-100% for collic Vestibular Evoked Myogenic Potentials (cVEMP). Compared with RCT, the sensitivity was 88-100% and the specificity was 69-100% for the Dynamic Visual Acuity test, respectively, 67-100% and 71-100% for the (video) Head Impulse Test and 83% and 86% for the ocular VEMP. Currently, due to methodological shortcoming, evidence on sensitivity and specificity of vestibular tests is unknown to moderate. Future research should focus on adequate sample sizes (subgroups >30).

  20. Use of shear wave elastography to differentiate benign and malignant breast lesions

    PubMed Central

    Olgun, Deniz Çebi; Korkmazer, Bora; Kılıç, Fahrettin; Dikici, Atilla Süleyman; Velidedeoğlu, Mehmet; Aydoğan, Fatih; Kantarcı, Fatih; Yılmaz, Mehmet Halit

    2014-01-01

    PURPOSE We aimed to determine the correlations between the elasticity values of solid breast masses and histopathological findings to define cutoff elasticity values differentiating malignant from benign lesions. MATERIALS and METHODS A total of 115 solid breast lesions of 109 consecutive patients were evaluated prospectively using shear wave elastography (SWE). Two orthogonal elastographic images of each lesion were obtained. Minimum, mean, and maximum elasticity values were calculated in regions of interest placed over the stiffest areas on the two images; we also calculated mass/fat elasticity ratios. Correlation of elastographic measurements with histopathological results were studied. RESULTS Eighty-three benign and thirty-two malignant lesions were histopathologically diagnosed. The minimum, mean, and maximum elasticity values, and the mass/fat elasticity ratios of malignant lesions, were significantly higher than those of benign lesions. The cutoff value was 45.7 kPa for mean elasticity (sensitivity, 96%; specificity, 95%), 54.3 kPa for maximum elasticity (sensitivity, 95%; specificity, 94%), 37.1 kPa for minimum elasticity (sensitivity, 96%; specificity, 95%), and 4.6 for the mass/fat elasticity ratio (sensitivity, 97%; specificity, 95%). CONCLUSION SWE yields additional valuable quantitative data to ultrasonographic examination on solid breast lesions. SWE may serve as a complementary tool for diagnosis of breast lesions. Long-term clinical studies are required to accurately select lesions requiring biopsy. PMID:24509183

Top