Ozone measurement systems improvements studies
NASA Technical Reports Server (NTRS)
Thomas, R. W.; Guard, K.; Holland, A. C.; Spurling, J. F.
1974-01-01
Results are summarized of an initial study of techniques for measuring atmospheric ozone, carried out as the first phase of a program to improve ozone measurement techniques. The study concentrated on two measurement systems, the electro chemical cell (ECC) ozonesonde and the Dobson ozone spectrophotometer, and consisted of two tasks. The first task consisted of error modeling and system error analysis of the two measurement systems. Under the second task a Monte-Carlo model of the Dobson ozone measurement technique was developed and programmed for computer operation.
Enhanced data consistency of a portable gait measurement system.
Lin, Hsien-I; Chiang, Y P
2013-11-01
A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.
Enhanced data consistency of a portable gait measurement system
NASA Astrophysics Data System (ADS)
Lin, Hsien-I.; Chiang, Y. P.
2013-11-01
A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.
Geil, Mark D
2007-01-01
Computer-aided design (CAD) and computer-aided manufacturing systems have been adapted for specific use in prosthetics, providing practitioners with a means to digitally capture the shape of a patient's limb, modify the socket model using software, and automatically manufacture either a positive model to be used in the fabrication of a socket or the socket itself. The digital shape captured is a three-dimensional (3-D) model from which standard anthropometric measures can be easily obtained. This study recorded six common anthropometric dimensions from CAD shape files of three foam positive models of the residual limbs of persons with transtibial amputations. Two systems were used to obtain 3-D models of the residual limb, a noncontact optical system and a contact-based electromagnetic field system, and both experienced practitioners and prosthetics students conducted measurements. Measurements were consistent; the mean range (difference of maximum and minimum) across all measurements was 0.96 cm. Both systems provided similar results, and both groups used the systems consistently. Students were slightly more consistent than practitioners but not to a clinically significant degree. Results also compared favorably with traditional measurement, with differences versus hand measurements about 5 mm. These results suggest the routine use of digital shape capture for collection of patient volume information.
Code of Federal Regulations, 2010 CFR
2010-01-01
... issued safety approval. (e) Measurement system consistency. For each analysis, an applicant must employ a consistent measurements system, whether English or metric, in its application and licensing information... writing, in English and filed in duplicate with the Federal Aviation Administration, Associate...
Measurements of Multi-star Systems LEO 5 and MKT 13
NASA Astrophysics Data System (ADS)
AlZaben, Faisal; Priest, Allen; Priest, Stephen; Qiu, Rex; Boyce, Grady; Boyce, Pat
2016-04-01
We report measurements of the position angles and separations of two multi-star systems observed during the fall of 2015. Image data was obtained using an online 17-inch iTelescope system in Nerpio, Spain. Image data was analyzed using Maxim DL Pro 6 and Mira Pro x64 software tools at the Army and Navy Academy in Carlsbad, California. Our measurements of the LEO 5 system are consistent with historical data, although inconclusive as to the nature of the system. Our measurements and the historical data for the MKT 13 system show a consistent linearity in the position angle and separation.
NASA Astrophysics Data System (ADS)
Kawaguchi, S.; Takemoto, M.; Osaka, K.; Nishibori, E.; Moriyoshi, C.; Kubota, Y.; Kuroiwa, Y.; Sugimoto, K.
2017-08-01
In this study, we developed a user-friendly automatic powder diffraction measurement system for Debye-Scherrer geometry using a capillary sample at beamline BL02B2 of SPring-8. The measurement system consists of six one-dimensional solid-state (MYTHEN) detectors, a compact auto-sampler, wide-range temperature control systems, and a gas handling system. This system enables to do the automatic measurement of temperature dependence of the diffraction patterns for multiple samples. We introduced two measurement modes in the MYTHEN system and developed new attachments for the sample environment such as a gas handling system. The measurement modes and the attachments can offer in situ and/or time-resolved measurements in an extended temperature range between 25 K and 1473 K and various gas atmospheres and pressures. The results of the commissioning and performance measurements using reference materials (NIST CeO2 674b and Si 640c), V2O3 and Ti2O3, and a nanoporous coordination polymer are presented.
Portable Instrumentation for Real-Time Measurement of Scour at Bridges
DOT National Transportation Integrated Search
2000-12-01
Portable scour-measuring systems were developed to meet the requirements of three different applications: bridge inspections, limited-detail data collection, and detailed data collection. A portable scour-measuring system consists of four components:...
Yi, G; Gallagher, M M; Yap, Y G; Guo, X H; Harrison, R; McDonald, J T; Camm, A J; Malik, M
2000-02-01
Heart rate variability (HRV) analysis from 24-hour ambulatory ECG has been widely used in risk stratification of patients after myocardial infarction (MI). The accuracy of HRV assessment is known to potentially vary when different commercial systems are used. However, the consistency of HRV measurements has never been fully investigated. Twenty-six post-MI patients (mean age 59 +/- 8 years, 22 men) were studied, of whom 13 succumbed to sudden cardiac death (SCD) within 1 year and 13 remained alive for at least 3 years (MI survivors). Each patient had a 24-hour Holter ECG recorded before hospital discharge. HRV analysis was performed four times from the same recordings using three different Holter tape analysis systems (Marquette, Reynolds, and CardioData) by four independent operators (CardioData system was used twice, once in the United Kingdom and once in the United States). Mean normal-to-normal RR intervals (mNN) and 3 HRV parameters (SDNN, RMSSD, and HRV triangular index [HRVi]) were derived from each recording. The consistency of mNN and HRV measurements was evaluated by coefficient of variance (CV) and by the Bland-Altman method. The results demonstrated that (1) all indices measured by different systems were statistically similar (P = NS) except the measurement of RMSSD (P = 0.01), (2) the measurements of mNN were highly reproducible with a maximum mean difference of 1.8 +/- 13.8 ms and maximum limits of agreement from -14.6 to +15.6 ms. The maximum mean differences were--1.8 +/- 1.4 unit and 4.4 +/- 9.6 ms for HRVi and SDNN, respectively, and RMSSD was less reproducible with a maximum mean difference of--11.1 +/- 11.5 ms, and limits of agreement from -16.2 to +9.6 ms; and (3) the consistency of mNN (CV 0.9% +/- 0.9%) was significantly higher than that of HRVi, SDNN, and RMSSD (P < 0.0001). The consistency of HRVi was similar to that of SDNN (4.8% +/- 2.1% vs 5.7% +/- 4.8%, P = 0.4), and the consistency of RMSSD (26.6% +/- 13.3%) was significantly lower than that of the other measurements (P < 0.00001). In conclusion, the measurements of mNN by different analytical systems are the most consistent among the parameters studied. The global 24-hour measurements of HRV (SDNN and HRVi) are highly reproducible, whereas the measurement of short-term HRV components (RMSSD) is significantly less reproducible.
Flap survey test of a combined surface blowing model: Flow measurements at static flow conditions
NASA Technical Reports Server (NTRS)
Fukushima, T.
1978-01-01
The Combined Surface Blowing (CSB) V/STOL lift/propulsion system consists of a blown flap system which deflects the exhaust from a turbojet engine over a system of flaps deployed at the trailing edge of the wing. Flow measurements consisting of velocity measurements using split film probes and total measure surveys using a miniature Kiel probe were made at control stations along the flap systems at two spanwise stations, the centerline of the nozzle and 60 percent of the nozzle span outboard of the centerline. Surface pressure measurements were made in the wing cove and the upper surface of the first flap element. The test showed a significant flow separation in the wing cove. The extent of the separation is so large that the flow into the first flap takes place only at the leading edge of the flap. The velocity profile measurements indicate that large spanwise (3 dimensional) flow may exist.
METHOD AND APPARATUS FOR MEASURING RADIATION
Reeder, S.D.
1962-04-17
A chemical dosimeter for measuring the progress of a radiation-induced oxidation-reduction reaction is described. The dosimeter comprises a container filled with an aqueous chemical oxidation-reduction system which reacts quantitatively to the radiation. An anode of the group consisting of antimony and tungsten and a cathode of the group consisting of gold and platnium are inserted into the system. Means are provided to stir the system and a potential sensing device is connected across the anode and cathode to detect voltage changes. (AEC)
Videogrammetric Model Deformation Measurement System User's Manual
NASA Technical Reports Server (NTRS)
Dismond, Harriett R.
2002-01-01
The purpose of this manual is to provide the user of the NASA VMD system, running the MDef software, Version 1.10, all information required to operate the system. The NASA Videogrammetric Model Deformation system consists of an automated videogrammetric technique used to measure the change in wing twist and bending under aerodynamic load in a wind tunnel. The basic instrumentation consists of a single CCD video camera and a frame grabber interfaced to a computer. The technique is based upon a single view photogrammetric determination of two-dimensional coordinates of wing targets with fixed (and known) third dimensional coordinate, namely the span-wise location. The major consideration in the development of the measurement system was that productivity must not be appreciably reduced.
Method used to test the imaging consistency of binocular camera's left-right optical system
NASA Astrophysics Data System (ADS)
Liu, Meiying; Wang, Hu; Liu, Jie; Xue, Yaoke; Yang, Shaodong; Zhao, Hui
2016-09-01
To binocular camera, the consistency of optical parameters of the left and the right optical system is an important factor that will influence the overall imaging consistency. In conventional testing procedure of optical system, there lacks specifications suitable for evaluating imaging consistency. In this paper, considering the special requirements of binocular optical imaging system, a method used to measure the imaging consistency of binocular camera is presented. Based on this method, a measurement system which is composed of an integrating sphere, a rotary table and a CMOS camera has been established. First, let the left and the right optical system capture images in normal exposure time under the same condition. Second, a contour image is obtained based on the multiple threshold segmentation result and the boundary is determined using the slope of contour lines near the pseudo-contour line. Third, the constraint of gray level based on the corresponding coordinates of left-right images is established and the imaging consistency could be evaluated through standard deviation σ of the imaging grayscale difference D (x, y) between the left and right optical system. The experiments demonstrate that the method is suitable for carrying out the imaging consistency testing for binocular camera. When the standard deviation 3σ distribution of imaging gray difference D (x, y) between the left and right optical system of the binocular camera does not exceed 5%, it is believed that the design requirements have been achieved. This method could be used effectively and paves the way for the imaging consistency testing of the binocular camera.
Barkman, William E.; Dow, Thomas A.; Garrard, Kenneth P.; Marston, Zachary
2016-07-12
Systems and methods for performing on-machine measurements and automatic part alignment, including: a measurement component operable for determining the position of a part on a machine; and an actuation component operable for adjusting the position of the part by contacting the part with a predetermined force responsive to the determined position of the part. The measurement component consists of a transducer. The actuation component consists of a linear actuator. Optionally, the measurement component and the actuation component consist of a single linear actuator operable for contacting the part with a first lighter force for determining the position of the part and with a second harder force for adjusting the position of the part. The actuation component is utilized in a substantially horizontal configuration and the effects of gravitational drop of the part are accounted for in the force applied and the timing of the contact.
21 CFR 866.5120 - Antismooth muscle antibody immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Systems § 866.5120 Antismooth muscle antibody immunological test system. (a) Identification. An antismooth muscle antibody immunological test system is a device that consists of the reagents used to measure by... serum. The measurements aid in the diagnosis of chronic hepatitis (inflammation of the liver) and...
Terrestrial essential climate variables (ECVs) at a glance
Stitt, Susan; Dwyer, John; Dye, Dennis; Josberger, Edward
2011-01-01
The Global Terrestrial Observing System, Global Climate Observing System, World Meteorological Organization, and Committee on Earth Observation Satellites all support consistent global land observations and measurements. To accomplish this goal, the Global Terrestrial Observing System defined 'essential climate variables' as measurements of atmosphere, oceans, and land that are technically and economically feasible for systematic observation and that are needed to meet the United Nations Framework Convention on Climate Change and requirements of the Intergovernmental Panel on Climate Change. The following are the climate variables defined by the Global Terrestrial Observing System that relate to terrestrial measurements. Several of them are currently measured most appropriately by in-place observations, whereas others are suitable for measurement by remote sensing technologies. The U.S. Geological Survey is the steward of the Landsat archive, satellite imagery collected from 1972 to the present, that provides a potential basis for deriving long-term, global-scale, accurate, timely and consistent measurements of many of these essential climate variables.
NASA Technical Reports Server (NTRS)
Groom, N. J.
1979-01-01
The rim inertial measuring system (RIMS) is introduced and an approach for extracting angular rate and linear acceleration information from a RIMS unit is presented and discussed. The RIMS consists of one or more small annular momentum control devices (AMCDs), mounted in a strapped down configuration, which are used to measure angular rates and linear accelerations of a moving vehicle. An AMCD consists of a spinning rim, a set of noncontacting magnetic bearings for supporting the rim, and a noncontacting electromagnetic spin motor. The approach for extracting angular rate and linear acceleration information is for a single spacecraft mounted RIMS unit.
The fiber optic system for the advanced topographic laser altimeter system instrument (ATLAS)
NASA Astrophysics Data System (ADS)
Ott, Melanie N.; Thomes, W. Joe; Onuma, Eleanya; Switzer, Robert; Chuska, Richard; Blair, Diana; Frese, Erich; Matyseck, Marc
2016-09-01
The Advanced Topographic Laser Altimeter System (ATLAS) Instrument has been in integration and testing over the past 18 months in preparation for the Ice, Cloud and Land Elevation Satellite - 2 (ICESat-2) Mission, scheduled to launch in 2017. ICESat-2 is the follow on to ICESat which launched in 2003 and operated until 2009. ATLAS will measure the elevation of ice sheets, glaciers and sea ice or the "cryosphere" (as well as terrain) to provide data for assessing the earth's global climate changes. Where ICESat's instrument, the Geo-Science Laser Altimeter (GLAS) used a single beam measured with a 70 m spot on the ground and a distance between spots of 170 m, ATLAS will measure a spot size of 10 m with a spacing of 70 cm using six beams to measure terrain height changes as small as 4 mm.[1] The ATLAS pulsed transmission system consists of two lasers operating at 532 nm with transmitter optics for beam steering, a diffractive optical element that splits the signal into 6 separate beams, receivers for start pulse detection and a wavelength tracking system. The optical receiver telescope system consists of optics that focus all six beams into optical fibers that feed a filter system that transmits the signal via fiber assemblies to the detectors. Also included on the instrument is a system that calibrates the alignment of the transmitted pulses to the receiver optics for precise signal capture. The larger electro optical subsystems for transmission, calibration, and signal receive, stay aligned and transmitting sufficiently due to the optical fiber system that links them together. The robust design of the fiber optic system, consisting of a variety of multi fiber arrays and simplex assemblies with multiple fiber core sizes and types, will enable the system to maintain consistent critical alignments for the entire life of the mission. Some of the development approaches used to meet the challenging optical system requirements for ATLAS are discussed here.
The fiber optic system for the Advanced Topographic Laser Altimeter System (ATLAS) instrument
Ott, Melanie N.; Thomes, Joe; Onuma, Eleanya; Switzer, Robert; Chuska, Richard; Blair, Diana; Frese, Erich; Matyseck, Marc
2017-01-01
The Advanced Topographic Laser Altimeter System (ATLAS) Instrument has been in integration and testing over the past 18 months in preparation for the Ice, Cloud and Land Elevation Satellite – 2 (ICESat-2) Mission, scheduled to launch in 2017. ICESat-2 is the follow on to ICESat which launched in 2003 and operated until 2009. ATLAS will measure the elevation of ice sheets, glaciers and sea ice or the “cryosphere” (as well as terrain) to provide data for assessing the earth’s global climate changes. Where ICESat’s instrument, the Geo-Science Laser Altimeter (GLAS) used a single beam measured with a 70 m spot on the ground and a distance between spots of 170 m, ATLAS will measure a spot size of 10 m with a spacing of 70 cm using six beams to measure terrain height changes as small as 4 mm.[1] The ATLAS pulsed transmission system consists of two lasers operating at 532 nm with transmitter optics for beam steering, a diffractive optical element that splits the signal into 6 separate beams, receivers for start pulse detection and a wavelength tracking system. The optical receiver telescope system consists of optics that focus all six beams into optical fibers that feed a filter system that transmits the signal via fiber assemblies to the detectors. Also included on the instrument is a system that calibrates the alignment of the transmitted pulses to the receiver optics for precise signal capture. The larger electro optical subsystems for transmission, calibration, and signal receive, stay aligned and transmitting sufficiently due to the optical fiber system that links them together. The robust design of the fiber optic system, consisting of a variety of multi fiber arrays and simplex assemblies with multiple fiber core sizes and types, will enable the system to maintain consistent critical alignments for the entire life of the mission. Some of the development approaches used to meet the challenging optical system requirements for ATLAS are discussed here. PMID:28280284
The fiber optic system for the Advanced Topographic Laser Altimeter System (ATLAS) instrument.
Ott, Melanie N; Thomes, Joe; Onuma, Eleanya; Switzer, Robert; Chuska, Richard; Blair, Diana; Frese, Erich; Matyseck, Marc
2016-08-28
The Advanced Topographic Laser Altimeter System (ATLAS) Instrument has been in integration and testing over the past 18 months in preparation for the Ice, Cloud and Land Elevation Satellite - 2 (ICESat-2) Mission, scheduled to launch in 2017. ICESat-2 is the follow on to ICESat which launched in 2003 and operated until 2009. ATLAS will measure the elevation of ice sheets, glaciers and sea ice or the "cryosphere" (as well as terrain) to provide data for assessing the earth's global climate changes. Where ICESat's instrument, the Geo-Science Laser Altimeter (GLAS) used a single beam measured with a 70 m spot on the ground and a distance between spots of 170 m, ATLAS will measure a spot size of 10 m with a spacing of 70 cm using six beams to measure terrain height changes as small as 4 mm.[1] The ATLAS pulsed transmission system consists of two lasers operating at 532 nm with transmitter optics for beam steering, a diffractive optical element that splits the signal into 6 separate beams, receivers for start pulse detection and a wavelength tracking system. The optical receiver telescope system consists of optics that focus all six beams into optical fibers that feed a filter system that transmits the signal via fiber assemblies to the detectors. Also included on the instrument is a system that calibrates the alignment of the transmitted pulses to the receiver optics for precise signal capture. The larger electro optical subsystems for transmission, calibration, and signal receive, stay aligned and transmitting sufficiently due to the optical fiber system that links them together. The robust design of the fiber optic system, consisting of a variety of multi fiber arrays and simplex assemblies with multiple fiber core sizes and types, will enable the system to maintain consistent critical alignments for the entire life of the mission. Some of the development approaches used to meet the challenging optical system requirements for ATLAS are discussed here.
The Fiber Optic System for the Advanced Topographic Laser Altimeter System (ATLAS) Instrument
NASA Technical Reports Server (NTRS)
Ott, Melanie N.; Thomes, Joe; Onuma, Eleanya; Switzer, Robert; Chuska, Richard; Blair, Diana; Frese, Erich; Matyseck, Marc
2016-01-01
The Advanced Topographic Laser Altimeter System (ATLAS) Instrument has been in integration and testing over the past 18 months in preparation for the Ice, Cloud and Land Elevation Satellite - 2 (ICESat-2) Mission, scheduled to launch in 2017. ICESat-2 is the follow on to ICESat which launched in 2003 and operated until 2009. ATLAS will measure the elevation of ice sheets, glaciers and sea ice or the "cryosphere" (as well as terrain) to provide data for assessing the earth's global climate changes. Where ICESat's instrument, the Geo-Science Laser Altimeter (GLAS) used a single beam measured with a 70 m spot on the ground and a distance between spots of 170 m, ATLAS will measure a spot size of 10 m with a spacing of 70 cm using six beams to measure terrain height changes as small as 4 mm. The ATLAS pulsed transmission system consists of two lasers operating at 532 nm with transmitter optics for beam steering, a diffractive optical element that splits the signal into 6 separate beams, receivers for start pulse detection and a wavelength tracking system. The optical receiver telescope system consists of optics that focus all six beams into optical fibers that feed a filter system that transmits the signal via fiber assemblies to the detectors. Also included on the instrument is a system that calibrates the alignment of the transmitted pulses to the receiver optics for precise signal capture. The larger electro optical subsystems for transmission, calibration, and signal receive, stay aligned and transmitting sufficiently due to the optical fiber system that links them together. The robust design of the fiber optic system, consisting of a variety of multi fiber arrays and simplex assemblies with multiple fiber core sizes and types, will enable the system to maintain consistent critical alignments for the entire life of the mission. Some of the development approaches used to meet the challenging optical system requirements for ATLAS are discussed here.
Design and Development of Patient Monitoring System
NASA Astrophysics Data System (ADS)
Hazwanie Azizulkarim, Azra; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi
2017-08-01
Patient monitoring system allows continuous monitoring of patient vital signs, support decision making among medical personnel and help enhance patient care. This system can consist of devices that measure, display and record human’s vital signs, including body temperature, heart rate, blood pressure and other health-related criteria. This paper proposes a system to monitor the patient’s conditions by monitoring the body temperature and pulse rate. The system consists of a pulse rate monitoring software and a wearable device that can measure a subject’s temperature and pulse rate only by using a fingertip. The device is able to record the measurement data and interface to PC via Arduino microcontroller. The recorded data can be viewed as a historical file or can be archived for further analysis. This work also describes the preliminary experimental results of the selected sensors to show the usefulness of the sensors for the proposed patient monitoring system.
Electron density measurements in STPX plasmas
NASA Astrophysics Data System (ADS)
Clark, Jerry; Williams, R.; Titus, J. B.; Mezonlin, E. D.; Akpovo, C.; Thomas, E.
2017-10-01
Diagnostics have been installed to measure the electron density of Spheromak Turbulent Physics Experiment (STPX) plasmas at Florida A. & M. University. An insertable probe, provided by Auburn University, consisting of a combination of a triple-tipped Langmuir probe and a radial array consisting of three ion saturation current / floating potential rings has been installed to measure instantaneous plasma density, temperature and plasma potential. As the ramp-up of the experimental program commences, initial electron density measurements from the triple-probe show that the electron density is on the order of 1019 particles/m3. For a passive measurement, a CO2 interferometer system has been designed and installed for measuring line-averaged densities and to corroborate the Langmuir measurements. We describe the design, calibration, and performance of these diagnostic systems on large volume STPX plasmas.
Implementation and performance evaluation open-source controller for precision control of gripper
NASA Astrophysics Data System (ADS)
Lee, Seung-Yong; Ham, Un-Hyeong; Park, Young-Woo; Jung, Hak-Sang; Jung, Il-Kyun; Lim, Sun
2017-12-01
This paper proposes integrating gripper embedded operating system, which consist of external interface structure for sophisticated gripper control. This system has multiple functions that control the gripping module and measure the pose of the gripper body with respect to contact environment. A controller based on open source only for the gripper is developed and an external communication interface between robot controller and gripper controller is designed. An experimental environment for the fixed-cycle test consists of integrating magic gripper software system and hardware on commercial business. As a result, a deviation is measured approximately 2% and the system were verified for gripper control.
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the vehicle at an angle that is consistent with the recommendation of the system's manufacturer. If... systems; stationary test. 325.57 Section 325.57 Transportation Other Regulations Relating to...; Stationary Test § 325.57 Location and operation of sound level measurement systems; stationary test. (a) The...
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... recommendation of the manufacturer of the sound level measurement system. (2) In no case shall the holder or... angle that is consistent with the recommendation of the system's manufacturer. If the manufacturer of... system; highway operations. 325.37 Section 325.37 Transportation Other Regulations Relating to...
Activation and evaluation of GaN photocathodes
NASA Astrophysics Data System (ADS)
Qian, Yunsheng; Chang, Benkang; Qiao, Jiangliang; Zhang, Yijun; Fu, Rongguo; Qiu, Yafeng
2009-09-01
Gallium Nitride (GaN) photocathodes are potentially attractive as UV detective materials and electron sources. Based on the activation and evaluation system for GaAs photocathode, which consists of ultra-high vacuum (UHV) activation chamber, multi-information measurement system, X-ray photoelectron spectroscopy (XPS), and ultraviolet ray photoelectron spectroscopy (UPS), the control and measurement system for the activation of UV photocathodes was developed. The developed system, which consists of Xenon lamp, monochromator with scanner, signal-processing module, power control unit of Cs and O source, A/D adapter, digital I/O card, computer and software, can control the activation of GaN photocathodes and measure on-line the spectral response curves of GaN photocathodes. GaN materials on sapphire substrate were grown by Metal-Organic Chemical Vapor Deposition (MOCVD) with p-type Mg doping. The GaN materials were activated by Cs-O. The spectral response and quantum efficiency (QE) were measured and calculated. The experiment results are discussed.
Torsional vibration measurements on rotating shaft system using laser doppler vibrometer
NASA Astrophysics Data System (ADS)
Xiang, Ling; Yang, Shixi; Gan, Chunbiao
2012-11-01
In this work, a laser torsional vibrameter was used to measure the torsion vibration of a rotating shaft system under electrical network impact. Based on the principles of laser Doppler velocimetry, the laser torsional vibrometer (LTV) are non-contact measurement of torsional oscillation of rotating shafts, offering significant advantages over conventional techniques. Furthermore, a highly complex shafting system is analyzed by a modified Riccati torsional transfer matrix. The system is modeled as a chain consisting of an elastic spring with concentrated mass points, and the multi-segments lumped mass model is established for this shafting system. By the modified Riccati torsional transfer matrix method, an accumulated calculation is effectively eliminated to obtain the natural frequencies. The electrical network impacts can activize the torsional vibration of shaft system, and the activized torsion vibration frequencies contained the natural frequencies of shaft system. The torsional vibrations of the shaft system were measured under electrical network impacts in laser Doppler torsional vibrometer. By comparisons, the natural frequencies by measurement were consistent with the values by calculation. The results verify the instrument is robust, user friendly and can be calibrated in situ. The laser torsional vibrometer represents a significant step forward in rotating machinery diagnostics.
Atmospheric Science Data Center
2013-06-26
... MEaSUREs ( Making Earth Science Data Records for Use in Research Environments ) supports the NASA Earth Science ... to expand understanding the Earth system using consistent records. Details: MEaSUREs Screenshot: ...
1980-09-02
laser or searchlight measurements . The study program consisted of three basic tasks: (1) a review of existing techniques for measuring aerosol extinction ...to aerosol extinction along a path can be deduced. Solutions to this problcaii fall into several classes. One class of solutions invoLves measuring ...employed such a windowless system to measure the absorption of an artificial aerosol consisting of quartz particles, using a CO 2 laser in the
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... system; highway operations. 325.37 Section 325.37 Transportation Other Regulations Relating to...; Highway Operations § 325.37 Location and operation of sound level measurement system; highway operations..., the holder must orient himself/herself relative to the highway in a manner consistent with the...
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... system; highway operations. 325.37 Section 325.37 Transportation Other Regulations Relating to...; Highway Operations § 325.37 Location and operation of sound level measurement system; highway operations..., the holder must orient himself/herself relative to the highway in a manner consistent with the...
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... system; highway operations. 325.37 Section 325.37 Transportation Other Regulations Relating to...; Highway Operations § 325.37 Location and operation of sound level measurement system; highway operations..., the holder must orient himself/herself relative to the highway in a manner consistent with the...
An OPO-Based Lidar System for Differential Absorption Measurements of Methane in the 3 micron region
NASA Technical Reports Server (NTRS)
Lee, S. W.; Zenker, T.; Chyba, T. H.
1998-01-01
A ground-based lidar system in the wavelength region of 1.45-4 microns for the remote measurement of methane is described. The laser transmitter consists of an injection-seeded Nd:YAG laser which pumps an OPO (optical parametric oscillator). The OPO output is tunable from 1.45-4 microns, with a bandwidth less than 500 MHz, and a pulse energy of 1 to 3 mJ at 3.29 microns. The receiver is cart-mounted and consists of a 14" telescope with 1.57 and 3.29 micron detector channels. A fast oscilloscope is used for data acquisition. The system performance will be tested through measurements of sources of atmospheric methane.
Equipment Development for Automatic Anthropometric Measurements
NASA Technical Reports Server (NTRS)
Cater, J. P.; Oakey, W. E.
1978-01-01
An automated procedure for measuring and recording the anthropometric active angles is presented. The small portable system consists of a microprocessor controlled video data acquisition system which measures single plane active angles using television video techniques and provides the measured data on sponsored-specified preformatted data sheets. This system, using only a single video camera, observes the end limits of the movement of a pair of separated lamps and calculates the vector angle between the extreme positions.
Cheng, Ralph T.; Gartner, Jeffrey W.; Mason, Jr., Robert R.; Costa, John E.; Plant, William J.; Spicer, Kurt R.; Haeni, F. Peter; Melcher, Nick B.; Keller, William C.; Hayes, Ken
2004-01-01
Accurate measurement of flow in the San Joaquin River at Vernalis, California, is vital to a wide range of Federal and State agencies, environmental interests, and water contractors. The U.S. Geological Survey uses a conventional stage-discharge rating technique to determine flows at Vernalis. Since the flood of January 1997, the channel has scoured and filled as much as 20 feet in some sections near the measurement site resulting in an unstable stage-discharge rating. In response to recent advances in measurement techniques and the need for more accurate measurement methods, the Geological Survey has undertaken a technology demonstration project to develop and deploy a radar-based streamflow measuring system on the bank of the San Joaquin River at Vernalis, California. The proposed flow-measurement system consists of a ground-penetrating radar system for mapping channel geometries, a microwave radar system for measuring surface velocities, and other necessary infrastructure. Cross-section information derived from ground penetrating radar provided depths similar to those measured by other instruments during the study. Likewise, surface-velocity patterns and magnitudes measured by the pulsed Doppler radar system are consistent with near surface current measurements derived from acoustic velocity instruments. Since the ratio of surface velocity to mean velocity falls to within a small range of theoretical value, using surface velocity as an index velocity to compute river discharge is feasable. Ultimately, the non-contact radar system may be used to make continuous, near-real-time flow measurements during high and medium flows. This report documents the data collected between April 14, 2002 and May 17, 2002 for the purposes of testing this radar based system. Further analyses of the data collected during this field effort will lead to further development and improvement of the system.
Trip optimization system and method for a train
Kumar, Ajith Kuttannair; Shaffer, Glenn Robert; Houpt, Paul Kenneth; Movsichoff, Bernardo Adrian; Chan, David So Keung
2017-08-15
A system for operating a train having one or more locomotive consists with each locomotive consist comprising one or more locomotives, the system including a locator element to determine a location of the train, a track characterization element to provide information about a track, a sensor for measuring an operating condition of the locomotive consist, a processor operable to receive information from the locator element, the track characterizing element, and the sensor, and an algorithm embodied within the processor having access to the information to create a trip plan that optimizes performance of the locomotive consist in accordance with one or more operational criteria for the train.
NASA Technical Reports Server (NTRS)
Bynum, B. G.; Gause, R. L.; Spier, R. A.
1971-01-01
System overcomes previous ergometer design and calibration problems including inaccurate measurements, large weight, size, and input power requirements, poor heat dissipation, high flammability, and inaccurate calibration. Device consists of lightweight, accurately controlled ergometer, restraint system, and calibration system.
Yanq, Xuming; Ye, Yijun; Xia, Yong; Wei, Xuanzhong; Wang, Zheyu; Ni, Hongmei; Zhu, Ying; Xu, Lingyu
2015-02-01
To develop a more precise and accurate method, and identified a procedure to measure whether an acupoint had been correctly located. On the face, we used an acupoint location from different acupuncture experts and obtained the most precise and accurate values of acupoint location based on the consistency information fusion algorithm, through a virtual simulation of the facial orientation coordinate system. Because of inconsistencies in each acupuncture expert's original data, the system error the general weight calculation. First, we corrected each expert of acupoint location system error itself, to obtain a rational quantification for each expert of acupuncture and moxibustion acupoint location consistent support degree, to obtain pointwise variable precision fusion results, to put every expert's acupuncture acupoint location fusion error enhanced to pointwise variable precision. Then, we more effectively used the measured characteristics of different acupuncture expert's acupoint location, to improve the measurement information utilization efficiency and acupuncture acupoint location precision and accuracy. Based on using the consistency matrix pointwise fusion method on the acupuncture experts' acupoint location values, each expert's acupoint location information could be calculated, and the most precise and accurate values of each expert's acupoint location could be obtained.
40 CFR 75.10 - General operating requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... part, a flow monitoring system and a CO2 continuous emission monitoring system that uses an O2...) Primary Measurement Requirement. The owner or operator shall measure opacity, and all SO2, NOX, and CO2... continuous emission monitoring system (consisting of a NOX pollutant concentration monitor and an O2 or CO2...
40 CFR 75.10 - General operating requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... part, a flow monitoring system and a CO2 continuous emission monitoring system that uses an O2...) Primary Measurement Requirement. The owner or operator shall measure opacity, and all SO2, NOX, and CO2... continuous emission monitoring system (consisting of a NOX pollutant concentration monitor and an O2 or CO2...
NASA Technical Reports Server (NTRS)
Roth, Don J.; Cosgriff, Laura M.; Harder, Bryan; Zhu, Dongming; Martin, Richard E.
2013-01-01
This study investigates the applicability of a novel noncontact single-sided terahertz electromagnetic measurement method for measuring thickness in dielectric coating systems having either dielectric or conductive substrate materials. The method does not require knowledge of the velocity of terahertz waves in the coating material. The dielectric coatings ranged from approximately 300 to 1400 m in thickness. First, the terahertz method was validated on a bulk dielectric sample to determine its ability to precisely measure thickness and density variation. Then, the method was studied on simulated coating systems. One simulated coating consisted of layered thin paper samples of varying thicknesses on a ceramic substrate. Another simulated coating system consisted of adhesive-backed Teflon adhered to conducting and dielectric substrates. Alumina samples that were coated with a ceramic adhesive layer were also investigated. Finally, the method was studied for thickness measurement of actual thermal barrier coatings (TBC) on ceramic substrates. The unique aspects and limitations of this method for thickness measurements are discussed.
Oudejans, S C C; Schippers, G M; Schramade, M H; Koeter, M W J; van den Brink, W
2011-04-01
To investigate internal consistency and factor structure of a questionnaire measuring learning capacity based on Senge's theory of the five disciplines of a learning organisation: Personal Mastery, Mental Models, Shared Vision, Team Learning, and Systems Thinking. Cross-sectional study. Substance-abuse treatment centres (SATCs) in The Netherlands. A total of 293 SATC employees from outpatient and inpatient treatment departments, financial and human resources departments. Psychometric properties of the Questionnaire for Learning Organizations (QLO), including factor structure, internal consistency, and interscale correlations. A five-factor model representing the five disciplines of Senge showed good fit. The scales for Personal Mastery, Shared Vision and Team Learning had good internal consistency, but the scales for Systems Thinking and Mental Models had low internal consistency. The proposed five-factor structure was confirmed in the QLO, which makes it a promising instrument to assess learning capacity in teams. The Systems Thinking and the Mental Models scales have to be revised. Future research should be aimed at testing criterion and discriminatory validity.
In-vitro corneal transparency measuring system
NASA Astrophysics Data System (ADS)
Ventura, Liliane; da Costa Vieira, Marcelo A.; Isaac, Flavio; Chiaradia, Caio; Faria de Sousa, Sidney J.
2001-06-01
A system for measuring the average corneal transparency of preserved corneas has been developed in order to provide a more accurate and standard report of the corneal tissue. The donated cornea transparency is one of the features to be analyzed previously to its indication for the transplant. The small portable system consists of two main parts: the optical and the electronic parts. The optical system consists of a white light, lenses and pin-holes that collimate white light beams that illuminates the cornea in its preservative medium. The light that passes through the cornea is detected by a resistive detector and the average corneal transparency is shown in a display. In order to obtain just the tissue transparency, the electronic circuit was built in a way that there is a baseline input of the preservative medium, previous to the measurement of the corneal transparency. Manipulating the system consists of three steps: (1) Adjusting the zero percentage in the absence of light (at this time the detectors in the dark); (2) Placing the preservative medium in the system and adjusting the 100% value (this is the baseline input); (3) Preserving the cornea and placing it in the system. The system provides the tissue transparency. The system is connected to an endothelium evaluation system for Slit Lamp, that we have developed, and statistics about the relationship of the corneal transparency and density of the endothelial cells will be provided in the next years. The system is being used in a public Eye Bank in Brasil.
Adaptive weld control for high-integrity welding applications
NASA Technical Reports Server (NTRS)
Powell, Bradley W.
1993-01-01
An advanced adaptive control weld system for high-integrity welding applications is presented. The system consists of a state-of-the-art weld control subsystem, motion control subsystem, and sensor subsystem which closes the loop on the process. The adaptive control subsystem (ACS), which is required to totally close the loop on weld process control, consists of a multiprocessor system, data acquisition hardware, and three welding sensors which provide measurements from all areas around the torch in real time. The ACS acquires all 'measurables' and feeds offset trims back into the weld control and motion control subsystems to modify the 'controllables' in order to maintain a previously defined weld quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shchory, Tal; Schifter, Dan; Lichtman, Rinat
Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive trackingmore » system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.« less
Shchory, Tal; Schifter, Dan; Lichtman, Rinat; Neustadter, David; Corn, Benjamin W
2010-11-15
In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy. Copyright © 2010 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Nigro, N. J.; Elkouh, A. F.
1975-01-01
The attitude of the balloon system is determined as a function of time if: (a) a method for simulating the motion of the system is available, and (b) the initial state is known. The initial state is obtained by fitting the system motion (as measured by sensors) to the corresponding output predicted by the mathematical model. In the case of the LACATE experiment the sensors consisted of three orthogonally oriented rate gyros and a magnetometer all mounted on the research platform. The initial state was obtained by fitting the angular velocity components measured with the gyros to the corresponding values obtained from the solution of the math model. A block diagram illustrating the attitude determination process employed for the LACATE experiment is shown. The process consists of three essential parts; a process for simulating the balloon system, an instrumentation system for measuring the output, and a parameter estimation process for systematically and efficiently solving the initial state. Results are presented and discussed.
The internal consistency of the North Sea carbonate system
NASA Astrophysics Data System (ADS)
Salt, Lesley A.; Thomas, Helmuth; Bozec, Yann; Borges, Alberto V.; de Baar, Hein J. W.
2016-05-01
In 2002 (February) and 2005 (August), the full suite of carbonate system parameters (total alkalinity (AT), dissolved inorganic carbon (DIC), pH, and partial pressure of CO2 (pCO2) were measured on two re-occupations of the entire North Sea basin, with three parameters (AT, DIC, pCO2) measured on four additional re-occupations, covering all four seasons, allowing an assessment of the internal consistency of the carbonate system. For most of the year, there is a similar level of internal consistency, with AT being calculated to within ± 6 μmol kg- 1 using DIC and pH, DIC to ± 6 μmol kg- 1 using AT and pH, pH to ± 0.008 using AT and pCO2, and pCO2 to ± 8 μatm using DIC and pH, with the dissociation constants of Millero et al. (2006). In spring, however, we observe a significant decline in the ability to accurately calculate the carbonate system. Lower consistency is observed with an increasing fraction of Baltic Sea water, caused by the high contribution of organic alkalinity in this water mass, not accounted for in the carbonate system calculations. Attempts to improve the internal consistency by accounting for the unconventional salinity-borate relationships in freshwater and the Baltic Sea, and through application of the new North Atlantic salinity-boron relationship (Lee et al., 2010), resulted in no significant difference in the internal consistency.
System noise analysis of the dumbbell tethered satellite for gravity-gradient measurements
NASA Technical Reports Server (NTRS)
Colombo, G.
1979-01-01
An analysis of the dumbbell gravity gradiometer concept for measuring short wavelength variations in the earth's gravity gradient is presented. Variations in the gradient are recorded by measuring tension variations in a vertically stabilized satellite consisting of heavy masses connected by a long wire or rod. Tension noise arises from the excitation of various mechanical oscillations of the system. The principal noise sources that were identified are fluctuations in atmospheric drag heating and drag force resulting from density variations and winds. Approximate analytical expressions are presented for the tension noise as a function of the system design parameters for various possible configurations. Computer simulations using numerical integration were performed to study the tension noise for several sample cases. Three designs consistent with Shuttle launch capabilities are discussed.
Beam profile measurements for target designators
NASA Astrophysics Data System (ADS)
Frank, J. D.
1985-02-01
An American aerospace company has conducted a number of investigations with the aim to improve on the tedious slow manual methods of measuring pulsed lasers for rangefinders, giving particular attention to beam divergence which is studied by varying aperture sizes and positions in the laser beam path. Three instruments have been developed to make the involved work easier to perform. One of these, the Automatic Laser Instrumentation and Measurement System (ALIMS), consists of an optical bench, a digital computer, and three bays of associated electronic instruments. ALIMS uses the aperture method to measure laser beam alignment and divergence. The Laser Intensity Profile System (LIPS) consists of a covered optical bench and a two bay electronic equipment and control console. The Automatic Laser Test Set (ALTS) utilizes a 50 x 50 silicon photodiode array to characterize military laser systems automatically. Details regarding the conducted determinations are discussed.
Measures of Autonomic Nervous System Regulation
2011-04-01
and most often used measures of ANS activation encompass non-invasive tools, which measure cardiac, skin conductance, respiratory , and vascular...regulation, osmotic balance, metabolism, digestion, excretion, and cardiac and respiratory activity. The ANS consists of the sympathetic and...modulate heart rate, as a function of the respiratory cycles. Generally, these two systems should be seen as permanently modulating vital functions to
Temperature measurement systems in wearable electronics
NASA Astrophysics Data System (ADS)
Walczak, S.; Gołebiowski, J.
2014-08-01
The aim of this paper is to present the concept of temperature measurement system, adapted to wearable electronics applications. Temperature is one of the most commonly monitored factor in smart textiles, especially in sportswear, medical and rescue products. Depending on the application, measured temperature could be used as an initial value of alert, heating, lifesaving or analysis system. The concept of the temperature measurement multi-point system, which consists of flexible screen-printed resistive sensors, placed on the T-shirt connected with the central unit and the power supply is elaborated in the paper.
NASA Astrophysics Data System (ADS)
Pavlov, S. S.; Dmitriev, A. Yu.; Chepurchenko, I. A.; Frontasyeva, M. V.
2014-11-01
The automation system for measurement of induced activity of gamma-ray spectra for multi-element high volume neutron activation analysis (NAA) was designed, developed and implemented at the reactor IBR-2 at the Frank Laboratory of Neutron Physics. The system consists of three devices of automatic sample changers for three Canberra HPGe detector-based gamma spectrometry systems. Each sample changer consists of two-axis of linear positioning module M202A by DriveSet company and disk with 45 slots for containers with samples. Control of automatic sample changer is performed by the Xemo S360U controller by Systec company. Positioning accuracy can reach 0.1 mm. Special software performs automatic changing of samples and measurement of gamma spectra at constant interaction with the NAA database.
Overview of the Spinal Cord Injury--Quality of Life (SCI-QOL) measurement system.
Tulsky, David S; Kisala, Pamela A; Victorson, David; Tate, Denise G; Heinemann, Allen W; Charlifue, Susan; Kirshblum, Steve C; Fyffe, Denise; Gershon, Richard; Spungen, Ann M; Bombardier, Charles H; Dyson-Hudson, Trevor A; Amtmann, Dagmar; Kalpakjian, Claire Z; Choi, Seung W; Jette, Alan M; Forchheimer, Martin; Cella, David
2015-05-01
The Spinal Cord Injury--Quality of Life (SCI-QOL) measurement system was developed to address the shortage of relevant and psychometrically sound patient reported outcome (PRO) measures available for clinical care and research in spinal cord injury (SCI) rehabilitation. Using a computer adaptive testing (CAT) approach, the SCI-QOL builds on the Patient Reported Outcomes Measurement Information System (PROMIS) and the Quality of Life in Neurological Disorders (Neuro-QOL) initiative. This initial manuscript introduces the background and development of the SCI-QOL measurement system. Greater detail is presented in the additional manuscripts of this special issue. Classical and contemporary test development methodologies were employed. Qualitative input was obtained from individuals with SCI and clinicians through interviews, focus groups, and cognitive debriefing. Item pools were field tested in a multi-site sample (n=877) and calibrated using item response theory methods. Initial reliability and validity testing was performed in a new sample of individuals with traumatic SCI (n=245). Five Model SCI System centers and one Department of Veterans Affairs Medical Center across the United States. Adults with traumatic SCI. n/a n/a The SCI-QOL consists of 19 item banks, including the SCI-Functional Index banks, and 3 fixed-length scales measuring physical, emotional, and social aspects of health-related QOL (HRQOL). The SCI-QOL measurement system consists of psychometrically sound measures for individuals with SCI. The manuscripts in this special issue provide evidence of the reliability and initial validity of this measurement system. The SCI-QOL also links to other measures designed for a general medical population.
Measures of Autonomic Nervous System
2011-04-01
activation encompass non-invasive tools, which measure cardiac, skin conductance, respiratory , and vascular activity. Choice of tools is dependent upon...digestion, excretion, and cardiac and respiratory activity. The ANS consists of the sympathetic and parasympathetic divisions and acts through a... respiratory cycles. Generally, these two systems should be seen as permanently modulating vital functions to achieve homeostasis. Since both systems are
NASA Technical Reports Server (NTRS)
Sutliff, Thomas J.
1999-01-01
The International Space Station opens for business in the year 2000, and with the opening, science investigations will take advantage of the unique conditions it provides as an on-orbit laboratory for research. With initiation of scientific studies comes a need to understand the environment present during research. The Space Acceleration Measurement System-II provides researchers a consistent means to understand the vibratory conditions present during experimentation on the International Space Station. The Space Acceleration Measurement System-II, or SAMS-II, detects vibrations present while the space station is operating. SAMS-II on-orbit hardware is comprised of two basic building block elements: a centralized control unit and multiple Remote Triaxial Sensors deployed to measure the acceleration environment at the point of scientific research, generally within a research rack. Ground Operations Equipment is deployed to complete the command, control and data telemetry elements of the SAMS-II implementation. Initially, operations consist of user requirements development, measurement sensor deployment and use, and data recovery on the ground. Future system enhancements will provide additional user functionality and support more simultaneous users.
Development of the radial neutron camera system for the HL-2A tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y. P., E-mail: zhangyp@swip.ac.cn; Yang, J. W.; Liu, Yi
2016-06-15
A new radial neutron camera system has been developed and operated recently in the HL-2A tokamak to measure the spatial and time resolved 2.5 MeV D-D fusion neutron, enhancing the understanding of the energetic-ion physics. The camera mainly consists of a multichannel collimator, liquid-scintillation detectors, shielding systems, and a data acquisition system. Measurements of the D-D fusion neutrons using the camera have been successfully performed during the 2015 HL-2A experiment campaign. The measurements show that the distribution of the fusion neutrons in the HL-2A plasma has a peaked profile, suggesting that the neutral beam injection beam ions in the plasmamore » have a peaked distribution. It also suggests that the neutrons are primarily produced from beam-target reactions in the plasma core region. The measurement results from the neutron camera are well consistent with the results of both a standard {sup 235}U fission chamber and NUBEAM neutron calculations. In this paper, the new radial neutron camera system on HL-2A and the first experimental results are described.« less
Minimal Distance to Approximating Noncontextual System as a Measure of Contextuality
NASA Astrophysics Data System (ADS)
Kujala, Janne V.
2017-07-01
Let random vectors Rc={Rpc:p\\in Pc} represent joint measurements of certain subsets Pc\\subset P of properties p\\in P in different contexts c\\in C. Such a system is traditionally called noncontextual if there exists a jointly distributed set {Qp:p\\in P} of random variables such that Rc has the same distribution as {Qp:p\\in Pc} for all c\\in C. A trivial necessary condition for noncontextuality and a precondition for many measures of contextuality is that the system is consistently connected, i.e., all Rpc,Rp^{c^' }},\\dots measuring the same property p\\in P have the same distribution. The contextuality-by-default (CbD) approach allows defining more general measures of contextuality that apply to inconsistently connected systems as well, but at the price of a higher computational cost. In this paper we propose a novel measure of contextuality that shares the generality of the CbD approach and the computational benefits of the previously proposed negative probability (NP) approach. The present approach differs from CbD in that instead of considering all possible joints of the double-indexed random variables Rpc, it considers all possible approximating single-indexed systems {Qp:p\\in P}. The degree of contextuality is defined based on the minimum possible probabilistic distance of the actual measurements Rc from {Qp:p\\in Pc}. We show that this measure, called the optimal approximation (OA) measure, agrees with a certain measure of contextuality of the CbD approach for all systems where each property enters in exactly two contexts. The OA measure can be calculated far more efficiently than the CbD measure and even more efficiently than the NP measure for sufficiently large systems. We also define a variant, the OA-NP measure of contextuality that agrees with the NP measure for consistently connected (non-signaling) systems while extending it to inconsistently connected systems.
A Procedure for Measuring Latencies in Brain-Computer Interfaces
Wilson, J. Adam; Mellinger, Jürgen; Schalk, Gerwin; Williams, Justin
2011-01-01
Brain-computer interface (BCI) systems must process neural signals with consistent timing in order to support adequate system performance. Thus, it is important to have the capability to determine whether a particular BCI configuration (i.e., hardware, software) provides adequate timing performance for a particular experiment. This report presents a method of measuring and quantifying different aspects of system timing in several typical BCI experiments across a range of settings, and presents comprehensive measures of expected overall system latency for each experimental configuration. PMID:20403781
A laser measurement system with multi-degree-of-freedom
NASA Astrophysics Data System (ADS)
Long, Lingli; Yang, Liangen; Wang, Xuanze; Zhai, Zhongsheng
2008-10-01
A new five-degree-of-freedom measuring system was developed as a linear guide. According to the principle of autocollimation, the system consisted of two semiconductor lasers, two right angle prisms, two lenses, two polarization spectroscopes and four quadrant Si-photoelectric detectors(QPD). Two axial displacements and three angular rotation degrees are measured by comparing the position of the spot center on the QPD. Repetitive simulations show that the accuracy of the system is 3" for measurement of angle, which proves the feasibility of this system. The advantages of the system include simple structure, easy operation, high accuracy, low cost and real-time work.
A Framework for Monitoring Progress Using Summary Measures of Health.
Madans, Jennifer H; Weeks, Julie D
2016-10-01
Initiatives designed to monitor health typically incorporate numerous specific measures of health and the health system to assess improvements, or lack thereof, for policy and program purposes. The addition of summary measures provides overarching information which is essential for determining whether the goals of such initiatives are met. Summary measures are identified that relate to the individual indicators but that also reflect movement in the various parts of the system. A hierarchical framework that is conceptually consistent and which utilizes a succinct number of summary measures incorporating indicators of functioning and participation is proposed. While a large set of individual indicators can be useful for monitoring progress, these individual indicators do not provide an overall evaluation of health, defined broadly, at the population level. A hierarchical framework consisting of summary measures is important for monitoring the success of health improvement initiatives. © The Author(s) 2016.
Microbial Fouling and its Effect on Power Generation.
1981-09-01
The tubular fouling reactor system (TFR) consists of a test block heat exchanger and a support system which includes water supply treatment facilities...and measurement instrumentation. Figure 8 is a schematic diagram of the system. Test block heat exchanger : The test block heat exchanger consists of...two adjacent aluminum cylindrical blocks (12.5 cm dia.) clamped to the section of tubing being tested (Fig. 9). The block is heated by electrical re
A wireless laser displacement sensor node for structural health monitoring.
Park, Hyo Seon; Kim, Jong Moon; Choi, Se Woon; Kim, Yousok
2013-09-30
This study describes a wireless laser displacement sensor node that measures displacement as a representative damage index for structural health monitoring (SHM). The proposed measurement system consists of a laser displacement sensor (LDS) and a customized wireless sensor node. Wireless communication is enabled by a sensor node that consists of a sensor module, a code division multiple access (CDMA) communication module, a processor, and a power module. An LDS with a long measurement distance is chosen to increase field applicability. For a wireless sensor node driven by a battery, we use a power control module with a low-power processor, which facilitates switching between the sleep and active modes, thus maximizing the power consumption efficiency during non-measurement and non-transfer periods. The CDMA mode is also used to overcome the limitation of communication distance, which is a challenge for wireless sensor networks and wireless communication. To evaluate the reliability and field applicability of the proposed wireless displacement measurement system, the system is tested onsite to obtain the required vertical displacement measurements during the construction of mega-trusses and an edge truss, which are the primary structural members in a large-scale irregular building currently under construction. The measurement values confirm the validity of the proposed wireless displacement measurement system and its potential for use in safety evaluations of structural elements.
Determining phase diagrams of gas-liquid systems using a microfluidic PVT.
Mostowfi, Farshid; Molla, Shahnawaz; Tabeling, Patrick
2012-11-07
A novel microfluidic device designed for analyzing phase diagrams of gas-liquid systems (PVT or pressure-volume-temperature measurements) is described. The method mimics the phase transition of a reservoir fluid as it travels through the wellbore from the formation to the surface. The device consists of a long serpentine microchannel etched in a silicon substrate. The local pressure inside the channel is measured using membrane-based optical pressure sensors positioned along the channel. Geometrical restrictions are placed along the microchannel in order to nucleate bubbles when nucleation conditions are met, thus preventing the development of a supersaturation state in the channel. We point out that a local equilibrium state between gas and liquid phases is achieved, which implies that equilibrium properties can be directly measured on the chip. We analyze different mixtures of hydrocarbon systems and, consistently with the preceding analysis, obtain excellent agreement between our technique and conventional measurements. From a practical viewpoint (important for the relevance of the technology), we observe that the measurement time of thermodynamic properties of gas-liquid systems is reduced from hours to minutes with the present device without compromising the measurement accuracy.
Mentiplay, Benjamin F; Perraton, Luke G; Bower, Kelly J; Pua, Yong-Hao; McGaw, Rebekah; Heywood, Sophie; Clark, Ross A
2015-07-16
The revised Xbox One Kinect, also known as the Microsoft Kinect V2 for Windows, includes enhanced hardware which may improve its utility as a gait assessment tool. This study examined the concurrent validity and inter-day reliability of spatiotemporal and kinematic gait parameters estimated using the Kinect V2 automated body tracking system and a criterion reference three-dimensional motion analysis (3DMA) marker-based camera system. Thirty healthy adults performed two testing sessions consisting of comfortable and fast paced walking trials. Spatiotemporal outcome measures related to gait speed, speed variability, step length, width and time, foot swing velocity and medial-lateral and vertical pelvis displacement were examined. Kinematic outcome measures including ankle flexion, knee flexion and adduction and hip flexion were examined. To assess the agreement between Kinect and 3DMA systems, Bland-Altman plots, relative agreement (Pearson's correlation) and overall agreement (concordance correlation coefficients) were determined. Reliability was assessed using intraclass correlation coefficients, Cronbach's alpha and standard error of measurement. The spatiotemporal measurements had consistently excellent (r≥0.75) concurrent validity, with the exception of modest validity for medial-lateral pelvis sway (r=0.45-0.46) and fast paced gait speed variability (r=0.73). In contrast kinematic validity was consistently poor to modest, with all associations between the systems weak (r<0.50). In those measures with acceptable validity, the inter-day reliability was similar between systems. In conclusion, while the Kinect V2 body tracking may not accurately obtain lower body kinematic data, it shows great potential as a tool for measuring spatiotemporal aspects of gait. Copyright © 2015 Elsevier Ltd. All rights reserved.
Calibration aspects of the JEM-EUSO mission
NASA Astrophysics Data System (ADS)
Adams, J. H.; Ahmad, S.; Albert, J.-N.; Allard, D.; Anchordoqui, L.; Andreev, V.; Anzalone, A.; Arai, Y.; Asano, K.; Ave Pernas, M.; Baragatti, P.; Barrillon, P.; Batsch, T.; Bayer, J.; Bechini, R.; Belenguer, T.; Bellotti, R.; Belov, K.; Berlind, A. A.; Bertaina, M.; Biermann, P. L.; Biktemerova, S.; Blaksley, C.; Blanc, N.; Błȩcki, J.; Blin-Bondil, S.; Blümer, J.; Bobik, P.; Bogomilov, M.; Bonamente, M.; Briggs, M. S.; Briz, S.; Bruno, A.; Cafagna, F.; Campana, D.; Capdevielle, J.-N.; Caruso, R.; Casolino, M.; Cassardo, C.; Castellinic, G.; Catalano, C.; Catalano, G.; Cellino, A.; Chikawa, M.; Christl, M. J.; Cline, D.; Connaughton, V.; Conti, L.; Cordero, G.; Crawford, H. J.; Cremonini, R.; Csorna, S.; Dagoret-Campagne, S.; de Castro, A. J.; De Donato, C.; de la Taille, C.; De Santis, C.; del Peral, L.; Dell'Oro, A.; De Simone, N.; Di Martino, M.; Distratis, G.; Dulucq, F.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Engel, R.; Falk, S.; Fang, K.; Fenu, F.; Fernández-Gómez, I.; Ferrarese, S.; Finco, D.; Flamini, M.; Fornaro, C.; Franceschi, A.; Fujimoto, J.; Fukushima, M.; Galeotti, P.; Garipov, G.; Geary, J.; Gelmini, G.; Giraudo, G.; Gonchar, M.; González Alvarado, C.; Gorodetzky, P.; Guarino, F.; Guzmán, A.; Hachisu, Y.; Harlov, B.; Haungs, A.; Hernández Carretero, J.; Higashide, K.; Ikeda, D.; Ikeda, H.; Inoue, N.; Inoue, S.; Insolia, A.; Isgrò, F.; Itow, Y.; Joven, E.; Judd, E. G.; Jung, A.; Kajino, F.; Kajino, T.; Kaneko, I.; Karadzhov, Y.; Karczmarczyk, J.; Karus, M.; Katahira, K.; Kawai, K.; Kawasaki, Y.; Keilhauer, B.; Khrenov, B. A.; Kim, J.-S.; Kim, S.-W.; Kim, S.-W.; Kleifges, M.; Klimov, P. A.; Kolev, D.; Kreykenbohm, I.; Kudela, K.; Kurihara, Y.; Kusenko, A.; Kuznetsov, E.; Lacombe, M.; Lachaud, C.; Lee, J.; Licandro, J.; Lim, H.; López, F.; Maccarone, M. C.; Mannheim, K.; Maravilla, D.; Marcelli, L.; Marini, A.; Martinez, O.; Masciantonio, G.; Mase, K.; Matev, R.; Medina-Tanco, G.; Mernik, T.; Miyamoto, H.; Miyazaki, Y.; Mizumoto, Y.; Modestino, G.; Monaco, A.; Monnier-Ragaigne, D.; Morales de los Ríos, J. A.; Moretto, C.; Morozenko, V. S.; Mot, B.; Murakami, T.; Murakami, M. Nagano; Nagata, M.; Nagataki, S.; Nakamura, T.; Napolitano, T.; Naumov, D.; Nava, R.; Neronov, A.; Nomoto, K.; Nonaka, T.; Ogawa, T.; Ogio, S.; Ohmori, H.; Olinto, A. V.; Orleański, P.; Osteria, G.; Panasyuk, M. I.; Parizot, E.; Park, I. H.; Park, H. W.; Pastircak, B.; Patzak, T.; Paul, T.; Pennypacker, C.; Perez Cano, S.; Peter, T.; Picozza, P.; Pierog, T.; Piotrowski, L. W.; Piraino, S.; Plebaniak, Z.; Pollini, A.; Prat, P.; Prévôt, G.; Prieto, H.; Putis, M.; Reardon, P.; Reyes, M.; Ricci, M.; Rodríguez, I.; Rodríguez Frías, M. D.; Ronga, F.; Roth, M.; Rothkaehl, H.; Roudil, G.; Rusinov, I.; Rybczyński, M.; Sabau, M. D.; Sáez-Cano, G.; Sagawa, H.; Saito, A.; Sakaki, N.; Sakata, M.; Salazar, H.; Sánchez, S.; Santangelo, A.; Santiago Crúz, L.; Sanz Palomino, M.; Saprykin, O.; Sarazin, F.; Sato, H.; Sato, M.; Schanz, T.; Schieler, H.; Scotti, V.; Segreto, A.; Selmane, S.; Semikoz, D.; Serra, M.; Sharakin, S.; Shibata, T.; Shimizu, H. M.; Shinozaki, K.; Shirahama, T.; Siemieniec-Oziȩbło, G.; Silva López, H. H.; Sledd, J.; Słomińska, K.; Sobey, A.; Sugiyama, T.; Supanitsky, D.; Suzuki, M.; Szabelska, B.; Szabelski, J.; Tajima, F.; Tajima, N.; Tajima, T.; Takahashi, Y.; Takami, H.; Takeda, M.; Takizawa, Y.; Tenzer, C.; Tibolla, O.; Tkachev, L.; Tokuno, H.; Tomida, T.; Tone, N.; Toscano, S.; Trillaud, F.; Tsenov, R.; Tsunesada, Y.; Tsuno, K.; Tymieniecka, T.; Uchihori, Y.; Unger, M.; Vaduvescu, O.; Valdés-Galicia, J. F.; Vallania, P.; Valore, L.; Vankova, G.; Vigorito, C.; Villaseñor, L.; von Ballmoos, P.; Wada, S.; Watanabe, J.; Watanabe, S.; Watts, J.; Weber, M.; Weiler, T. J.; Wibig, T.; Wiencke, L.; Wille, M.; Wilms, J.; Włodarczyk, Z.; Yamamoto, T.; Yamamoto, Y.; Yang, J.; Yano, H.; Yashin, I. V.; Yonetoku, D.; Yoshida, K.; Yoshida, S.; Young, R.; Zotov, M. Yu.; Zuccaro Marchi, A.
2015-11-01
The JEM-EUSO telescope will be, after calibration, a very accurate instrument which yields the number of received photons from the number of measured photo-electrons. The project is in phase A (demonstration of the concept) including already operating prototype instruments, i.e. many parts of the instrument have been constructed and tested. Calibration is a crucial part of the instrument and its use. The focal surface (FS) of the JEM-EUSO telescope will consist of about 5000 photo-multiplier tubes (PMTs), which have to be well calibrated to reach the required accuracy in reconstructing the air-shower parameters. The optics system consists of 3 plastic Fresnel (double-sided) lenses of 2.5 m diameter. The aim of the calibration system is to measure the efficiencies (transmittances) of the optics and absolute efficiencies of the entire focal surface detector. The system consists of 3 main components: (i) Pre-flight calibration devices on ground, where the efficiency and gain of the PMTs will be measured absolutely and also the transmittance of the optics will be. (ii) On-board relative calibration system applying two methods: a) operating during the day when the JEM-EUSO lid will be closed with small light sources on board. b) operating during the night, together with data taking: the monitoring of the background rate over identical sites. (iii) Absolute in-flight calibration, again, applying two methods: a) measurement of the moon light, reflected on high altitude, high albedo clouds. b) measurements of calibrated flashes and tracks produced by the Global Light System (GLS). Some details of each calibration method will be described in this paper.
Overview of the Spinal Cord Injury – Quality of Life (SCI-QOL) measurement system
Tulsky, David S.; Kisala, Pamela A.; Victorson, David; Tate, Denise G.; Heinemann, Allen W.; Charlifue, Susan; Kirshblum, Steve C.; Fyffe, Denise; Gershon, Richard; Spungen, Ann M.; Bombardier, Charles H.; Dyson-Hudson, Trevor A.; Amtmann, Dagmar; Z. Kalpakjian, Claire; W. Choi, Seung; Jette, Alan M.; Forchheimer, Martin; Cella, David
2015-01-01
Context/Objective The Spinal Cord Injury – Quality of Life (SCI-QOL) measurement system was developed to address the shortage of relevant and psychometrically sound patient reported outcome (PRO) measures available for clinical care and research in spinal cord injury (SCI) rehabilitation. Using a computer adaptive testing (CAT) approach, the SCI-QOL builds on the Patient Reported Outcomes Measurement Information System (PROMIS) and the Quality of Life in Neurological Disorders (Neuro-QOL) initiative. This initial manuscript introduces the background and development of the SCI-QOL measurement system. Greater detail is presented in the additional manuscripts of this special issue. Design Classical and contemporary test development methodologies were employed. Qualitative input was obtained from individuals with SCI and clinicians through interviews, focus groups, and cognitive debriefing. Item pools were field tested in a multi-site sample (n = 877) and calibrated using item response theory methods. Initial reliability and validity testing was performed in a new sample of individuals with traumatic SCI (n = 245). Setting Five Model SCI System centers and one Department of Veterans Affairs Medical Center across the United States. Participants Adults with traumatic SCI. Interventions n/a Outcome Measures n/a Results The SCI-QOL consists of 19 item banks, including the SCI-Functional Index banks, and 3 fixed-length scales measuring physical, emotional, and social aspects of health-related QOL (HRQOL). Conclusion The SCI-QOL measurement system consists of psychometrically sound measures for individuals with SCI. The manuscripts in this special issue provide evidence of the reliability and initial validity of this measurement system. The SCI-QOL also links to other measures designed for a general medical population. PMID:26010962
Relative-Error-Covariance Algorithms
NASA Technical Reports Server (NTRS)
Bierman, Gerald J.; Wolff, Peter J.
1991-01-01
Two algorithms compute error covariance of difference between optimal estimates, based on data acquired during overlapping or disjoint intervals, of state of discrete linear system. Provides quantitative measure of mutual consistency or inconsistency of estimates of states. Relative-error-covariance concept applied, to determine degree of correlation between trajectories calculated from two overlapping sets of measurements and construct real-time test of consistency of state estimates based upon recently acquired data.
Real-time measurement and monitoring of absorbed dose for electron beams
NASA Astrophysics Data System (ADS)
Korenev, Sergey; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon
2004-09-01
The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators.
NASA Technical Reports Server (NTRS)
Bryant, W. H.; Morrell, F. R.
1981-01-01
Attention is given to a redundant strapdown inertial measurement unit for integrated avionics. The system consists of four two-degree-of-freedom turned rotor gyros and four two-degree-of-freedom accelerometers in a skewed and separable semi-octahedral array. The unit is coupled through instrument electronics to two flight computers which compensate sensor errors. The flight computers are interfaced to the microprocessors and process failure detection, isolation, redundancy management and flight control/navigation algorithms. The unit provides dual fail-operational performance and has data processing frequencies consistent with integrated avionics concepts presently planned.
Design and construction of portable survey meter
NASA Astrophysics Data System (ADS)
Singseeta, W.; Thong-aram, D.; Pencharee, S.
2017-09-01
This work was aimed to design and construction of portable survey meter for radiation dose measuring. The designed system consists of 4 main parts consisting of low voltage power supply, radiation detection, radiation measurement and data display part on android phone. The test results show that the ripple voltage of low voltage power supply is less than 1%, the maximum integral counts are found to be 104 counts per second and the maximum distance of wireless commination between the server and the client is about 10 meter. It was found that the developed system had small size and light weight for portable instrument.
Nonintrusive biosignal measurement system in a vehicle.
Lee, Haet Bit; Choi, Jong Min; Kim, Jung Soo; Kim, Yun Seong; Baek, Hyun Jae; Ryu, Myung Suk; Sohn, Ryang Hee; Park, Kwang Suk
2007-01-01
Measurement of driver's state is important in both daily healthcare and prevention of car accidents. Existing measurement methods, however, are too complex and uncomfortable to measure for everyday. A nonintrusive biosignal monitoring system is demanded for increasing the accessibility. In this paper, we proposed a nonintrusive measurement system integrated in a vehicle for recording electrocardiographic (ECG) signals and tested the performance of the system. The system consists of dry electrodes attached to the steering wheel and a wireless communication module using a Bluetooth device. ECG signals measured by our system were compared with those by a conventional system employing wet electrodes during real city road driving. Various parameters used for HRV analysis in time and frequency domain showed no significant differences between the two simultaneously measured ECG signals. The result implies the possibility that developed system could have a potential to monitor health information in a vehicle instead of commercial equipments.
Identification and Quantitative Measurements of Chemical Species by Mass Spectrometry
NASA Technical Reports Server (NTRS)
Zondlo, Mark A.; Bomse, David S.
2005-01-01
The development of a miniature gas chromatograph/mass spectrometer system for the measurement of chemical species of interest to combustion is described. The completed system is a fully-contained, automated instrument consisting of a sampling inlet, a small-scale gas chromatograph, a miniature, quadrupole mass spectrometer, vacuum pumps, and software. A pair of computer-driven valves controls the gas sampling and introduction to the chromatographic column. The column has a stainless steel exterior and a silica interior, and contains an adsorbent of that is used to separate organic species. The detection system is based on a quadrupole mass spectrometer consisting of a micropole array, electrometer, and a computer interface. The vacuum system has two miniature pumps to maintain the low pressure needed for the mass spectrometer. A laptop computer uses custom software to control the entire system and collect the data. In a laboratory demonstration, the system separated calibration mixtures containing 1000 ppm of alkanes and alkenes.
ERIC Educational Resources Information Center
Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald
2011-01-01
This technical report describes the process of development and piloting of reading comprehension measures that are appropriate for seventh-grade students as part of an online progress screening and monitoring assessment system, http://easycbm.com. Each measure consists of an original fictional story of approximately 1,600 to 1,900 words with 20…
APMS 3.0 Flight Analyst Guide: Aviation Performance Measuring System
NASA Technical Reports Server (NTRS)
Jay, Griff; Prothero, Gary; Romanowski, Timothy; Lynch, Robert; Lawrence, Robert; Rosenthal, Loren
2004-01-01
The Aviation Performance Measuring System (APMS) is a method-embodied in software-that uses mathematical algorithms and related procedures to analyze digital flight data extracted from aircraft flight data recorders. APMS consists of an integrated set of tools used to perform two primary functions: a) Flight Data Importation b) Flight Data Analysis.
21 CFR 866.5500 - Hypersensitivity pneumonitis immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... system. 866.5500 Section 866.5500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Systems § 866.5500 Hypersensitivity pneumonitis immunological test system. (a) Identification. A hypersensitivity pneumonitis immunological test system is a device that consists of the reagents used to measure by...
21 CFR 866.5500 - Hypersensitivity pneumonitis immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... system. 866.5500 Section 866.5500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Systems § 866.5500 Hypersensitivity pneumonitis immunological test system. (a) Identification. A hypersensitivity pneumonitis immunological test system is a device that consists of the reagents used to measure by...
21 CFR 866.5500 - Hypersensitivity pneumonitis immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... system. 866.5500 Section 866.5500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Systems § 866.5500 Hypersensitivity pneumonitis immunological test system. (a) Identification. A hypersensitivity pneumonitis immunological test system is a device that consists of the reagents used to measure by...
21 CFR 866.5500 - Hypersensitivity pneumonitis immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... system. 866.5500 Section 866.5500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Systems § 866.5500 Hypersensitivity pneumonitis immunological test system. (a) Identification. A hypersensitivity pneumonitis immunological test system is a device that consists of the reagents used to measure by...
21 CFR 866.5570 - Lactoferrin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... that consists of the reagents used to measure by immunochemical techniques the lactoferrin (an iron... fluids, and tissues. Measurement of lactoferrin may aid in the diagnosis of an inherited deficiency of...
21 CFR 866.5570 - Lactoferrin immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... that consists of the reagents used to measure by immunochemical techniques the lactoferrin (an iron... fluids, and tissues. Measurement of lactoferrin may aid in the diagnosis of an inherited deficiency of...
21 CFR 866.5570 - Lactoferrin immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... that consists of the reagents used to measure by immunochemical techniques the lactoferrin (an iron... fluids, and tissues. Measurement of lactoferrin may aid in the diagnosis of an inherited deficiency of...
21 CFR 866.5570 - Lactoferrin immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... that consists of the reagents used to measure by immunochemical techniques the lactoferrin (an iron... fluids, and tissues. Measurement of lactoferrin may aid in the diagnosis of an inherited deficiency of...
Lanning, Sharon K; Best, Al M; Temple, Henry J; Richards, Philip S; Carey, Allison; McCauley, Laurie K
2006-02-01
Accurate and consistent radiographic interpretation among clinical instructors is needed for assessment of teaching, student performance, and patient care. The purpose of this investigation was to determine if the method of radiographic viewing affects accuracy and consistency of instructors' determinations of bone loss. Forty-one clinicians who provide instruction in a dental school clinical teaching program (including periodontists, general dentists, periodontal graduate students, and dental hygienists) quantified bone loss for up to twenty-five teeth into four descriptive categories using a view box for plain film viewing or a projection system for digitized image viewing. Ratings were compared to the correct category as determined by direct measurement using the Schei ruler. Agreement with the correct choice for the view box and projection system was 70.2 percent and 64.5 percent, respectively. The mean difference was better for a projection system due to small rater error by graduate students. Projection system ratings were slightly less consistent than view box ratings. Dental hygiene faculty ratings were the most consistent but least accurate. Although the projection system resulted in slightly reduced accuracy and consistency among instructors, training sessions utilizing a single method for projecting digitized radiographic images have their advantages and may positively influence dental education and patient care by enhancing accuracy and consistency of radiographic interpretation among instructors.
Tutorial: Crystal orientations and EBSD — Or which way is up?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britton, T.B., E-mail: b.britton@imperial.ac.uk; Jiang, J.; Guo, Y.
2016-07-15
Electron backscatter diffraction (EBSD) is an automated technique that can measure the orientation of crystals in a sample very rapidly. There are many sophisticated software packages that present measured data. Unfortunately, due to crystal symmetry and differences in the set-up of microscope and EBSD software, there may be accuracy issues when linking the crystal orientation to a particular microstructural feature. In this paper we outline a series of conventions used to describe crystal orientations and coordinate systems. These conventions have been used to successfully demonstrate that a consistent frame of reference is used in the sample, unit cell, pole figuremore » and diffraction pattern frames of reference. We establish a coordinate system rooted in measurement of the diffraction pattern and subsequently link this to all other coordinate systems. A fundamental outcome of this analysis is to note that the beamshift coordinate system needs to be precisely defined for consistent 3D microstructure analysis. This is supported through a series of case studies examining particular features of the microscope settings and/or unambiguous crystallographic features. These case studies can be generated easily in most laboratories and represent an opportunity to demonstrate confidence in use of recorded orientation data. Finally, we include a simple software tool, written in both MATLAB® and Python, which the reader can use to compare consistency with their own microscope set-up and which may act as a springboard for further offline analysis. - Highlights: • Presentation of conventions used to describe crystal orientations • Three case studies that outline how conventions are consistent • Demonstrates a pathway for calibration and validation of EBSD based orientation measurements • EBSD computer code supplied for validation by the reader.« less
Application of low-power, high-rate PCM telemetry in a helicopter instrumentation system
NASA Technical Reports Server (NTRS)
Thomas, Mitchel E.; Diamond, John K.
1987-01-01
The use of low-power, high-rate pulse code modulation (PCM) in a helicopter instrumentation system is examined. A Helicopter Instrumentation and Recording System (HIARS) was developed to obtain main rotor blade measurements and fuselage performance measurements. The HIARS consists of a low-power PCM telemeter, a digital PCM system, an optical rotor position sensor, and a PCM decommutation unit; the components and functions of these subsystems are described. Flight tests were conducted to evaluate the ability of the HIARS to measure aircraft parameters. The test data reveal that the PCM telemetry is applicable to helicopter instrumentation systems.
Bluetooth-based distributed measurement system
NASA Astrophysics Data System (ADS)
Tang, Baoping; Chen, Zhuo; Wei, Yuguo; Qin, Xiaofeng
2007-07-01
A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit.
Remote online monitoring and measuring system for civil engineering structures
NASA Astrophysics Data System (ADS)
Kujawińska, Malgorzata; Sitnik, Robert; Dymny, Grzegorz; Karaszewski, Maciej; Michoński, Kuba; Krzesłowski, Jakub; Mularczyk, Krzysztof; Bolewicki, Paweł
2009-06-01
In this paper a distributed intelligent system for civil engineering structures on-line measurement, remote monitoring, and data archiving is presented. The system consists of a set of optical, full-field displacement sensors connected to a controlling server. The server conducts measurements according to a list of scheduled tasks and stores the primary data or initial results in a remote centralized database. Simultaneously the server performs checks, ordered by the operator, which may in turn result with an alert or a specific action. The structure of whole system is analyzed along with the discussion on possible fields of application and the ways to provide a relevant security during data transport. Finally, a working implementation consisting of a fringe projection, geometrical moiré, digital image correlation and grating interferometry sensors and Oracle XE database is presented. The results from database utilized for on-line monitoring of a threshold value of strain for an exemplary area of interest at the engineering structure are presented and discussed.
21 CFR 866.5090 - Antimitochondrial antibody immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Systems § 866.5090 Antimitochondrial antibody immunological test system. (a) Identification. An antimitochondrial antibody immunological test system is a device that consists of the reagents used to measure by... of diseases that produce a spectrum of autoantibodies (antibodies produced against the body's own...
WRAP-RIB antenna technology development
NASA Technical Reports Server (NTRS)
Freeland, R. E.; Garcia, N. F.; Iwamoto, H.
1985-01-01
The wrap-rib deployable antenna concept development is based on a combination of hardware development and testing along with extensive supporting analysis. The proof-of-concept hardware models are large in size so they will address the same basic problems associated with the design fabrication, assembly and test as the full-scale systems which were selected to be 100 meters at the beginning of the program. The hardware evaluation program consists of functional performance tests, design verification tests and analytical model verification tests. Functional testing consists of kinematic deployment, mesh management and verification of mechanical packaging efficiencies. Design verification consists of rib contour precision measurement, rib cross-section variation evaluation, rib materials characterizations and manufacturing imperfections assessment. Analytical model verification and refinement include mesh stiffness measurement, rib static and dynamic testing, mass measurement, and rib cross-section characterization. This concept was considered for a number of potential applications that include mobile communications, VLBI, and aircraft surveillance. In fact, baseline system configurations were developed by JPL, using the appropriate wrap-rib antenna, for all three classes of applications.
Dausey, David J; Chandra, Anita; Schaefer, Agnes G; Bahney, Ben; Haviland, Amelia; Zakowski, Sarah; Lurie, Nicole
2008-09-01
We tested telephone-based disease surveillance systems in local health departments to identify system characteristics associated with consistent and timely responses to urgent case reports. We identified a stratified random sample of 74 health departments and conducted a series of unannounced tests of their telephone-based surveillance systems. We used regression analyses to identify system characteristics that predicted fast connection with an action officer (an appropriate public health professional). Optimal performance in consistently connecting callers with an action officer in 30 minutes or less was achieved by 31% of participating health departments. Reaching a live person upon dialing, regardless of who that person was, was the strongest predictor of optimal performance both in being connected with an action officer and in consistency of connection times. Health departments can achieve optimal performance in consistently connecting a caller with an action officer in 30 minutes or less and may improve performance by using a telephone-based disease surveillance system in which the phone is answered by a live person at all times.
Optical position measurement for a Large Gap Magnetic Suspension System
NASA Technical Reports Server (NTRS)
Welch, Sharon S.; Shelton, Kevin J.; Clemmons, James I.
1991-01-01
This paper describes the design of an optical position measurement system which is being built as part of the NASA Langley Large Gap Magnetic Suspension System (LGMSS). The LGMSS is a five degree-of-freedom, large-gap magnetic suspension system which is being built for Langley Research Center as part of the Advanced Controls Test Facility (ACTF). The LGMSS consists of a planar array of electromagnets which levitate and position a cylindrically shaped model containing a permanent magnet core. The optical position measurement system provides information on the location and orientation of the model to the LGMSS control system to stabilize levitation of the model.
An Astrometric Observation of Binary Star System WDS 15559-0210 at the Great Basin Observatory
NASA Astrophysics Data System (ADS)
Musegades, Lila; Niebuhr, Cole; Graham, Mackenzie; Poore, Andrew; Freed, Rachel; Kenney, John; Genet, Russell
2018-04-01
Researchers at Concordia University Irvine measured the position angle and separation of the double star system WDS 15559-0210 using a SBIG STX-16803 CCD camera on the PlaneWave 0.7-m CDK 700 telescope at the Great Basin Observatory. Images of the binary star system were measured using AstroImageJ software. Twenty observations of WDS 15559-0210 were measured and analyzed. The calculated mean resulted in a position angle of 345.95° and a separation of 5.94". These measurements were consistent with the previous values for this binary system listed in the Washington Double Star Catalog.
Measuring complete quantum states with a single observable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng Xinhua; Suter, Dieter; Du Jiangfeng
2007-10-15
Experimental determination of an unknown quantum state usually requires several incompatible measurements. However, it is also possible to determine the full quantum state from a single, repeated measurement. For this purpose, the quantum system whose state is to be determined is first coupled to a second quantum system (the 'assistant') in such a way that part of the information in the quantum state is transferred to the assistant. The actual measurement is then performed on the enlarged system including the original system and the assistant. We discuss in detail the requirements of this procedure and experimentally implement it on amore » simple quantum system consisting of nuclear spins.« less
NASA Astrophysics Data System (ADS)
Nazihah Mat Daud, Anis; Jaafar, Rosly; Kadri Ayop, Shahrul; Supar Rohani, Md
2018-04-01
This paper discusses the development of a computerized acoustic characterization system of non-porous solid tissue mimicking materials. This system employs an alternative pulse echo immersion technique and consists of a pulser/receiver generator, a transducer used as both a transmitter and a receiver, a digital oscilloscope, and a personal computer with a custom-developed program installed. The program was developed on the LabVIEW 2012 platform and comprises two main components, a user interface and a block diagram. The user interface consists of three panels: a signal acquisition and selection panel, a display panel, and a calculation panel. The block diagram comprises four blocks: a signal acquisition block, a peak signal analysis block, an acoustic properties calculation and display block, and an additional block. Interestingly, the system can be operated in both online and offline modes. For the online mode, the measurements are performed by connecting the system with a Rigol DS2000 Series digital oscilloscope. In contrast, the measurements are carried out by processing the saved data on the computer for the offline mode. The accuracy and consistency of the developed system was validated by a KB-Aerotech Alpha Series transducer with 5 MHz center frequency and a Rigol DS2202 two-channel 200 MHz 2 GSa s-1 digital oscilloscope, based on the measurement of the acoustic properties of three poly(methyl methacrylate) samples immersed in a medium at a temperature of (24.0 ± 0.1) °C. The findings indicated that the accuracy and consistency of the developed system was exceptionally high, within a 1.04% margin of error compared to the reference values. As such, this computerized system can be efficiently used for the acoustic characterization of non-porous solid tissues, given its spontaneous display of results, user-friendly interface, and convenient hardware connection.
Electromagnetic interference in electrical systems of motor vehicles
NASA Astrophysics Data System (ADS)
Dziubiński, M.; Drozd, A.; Adamiec, M.; Siemionek, E.
2016-09-01
Electronic ignition system affects the electronic equipment of the vehicle by electric and magnetic fields. The measurement of radio electromagnetic interference originating from the ignition system affecting the audiovisual test bench was carried out with a variable speed of the ignition system. The paper presents measurements of radio electromagnetic interference in automobiles. In order to determine the level of electromagnetic interference, the audiovisual test bench was equipped with a set of meters for power consumption and assessment of the level of electromagnetic interference. Measurements of the electromagnetic interference level within the audiovisual system were performed on an experimental test bench consisting of the ignition system, starting system and charging system with an alternator and regulator.
Description and Applications for an Automated Inertial Azimuth Measuring System,
specialized field environment. The present system consists of two integrated inertial sensors , an angle transfer system, a tiltmeter array and a...optical path. Highly sensitive tiltmeters are used to measure and correct for errors due to base motions of the inertial sensors . Data handling and...microprocessor. The inertial sensors use gimbal-mounted rate gyrocompasses to indicate the azimuths of two transfer mirrors with respect to true North. The
NASA Technical Reports Server (NTRS)
Dube, W. P.; Sparks, L. L.; Slifka, A. J.; Bitsy, R. M.
1990-01-01
Advanced aerospace designs require thermal insulation systems which are consistent with cryogenic fluids, high thermal loads, and design restrictions such as weight and volume. To evaluate the thermal performance of these insulating systems, an apparatus capable of measuring thermal conductivity using extreme temperature differences (27 to 1100 K) is being developed. This system is described along with estimates of precision and accuracy in selected operating conditions. Preliminary data are presented.
NASA Astrophysics Data System (ADS)
Dube, W. P.; Sparks, L. L.; Slifka, A. J.; Bitsy, R. M.
Advanced aerospace designs require thermal insulation systems which are consistent with cryogenic fluids, high thermal loads, and design restrictions such as weight and volume. To evaluate the thermal performance of these insulating systems, an apparatus capable of measuring thermal conductivity using extreme temperature differences (27 to 1100 K) is being developed. This system is described along with estimates of precision and accuracy in selected operating conditions. Preliminary data are presented.
Krzysztof, Naus; Aleksander, Nowak
2016-01-01
The article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base Line) system. The problem of underwater positioning and the conceptual design of the BAUV navigation system constructed at the Naval Academy (Polish Naval Academy—PNA) are presented in the first part of the paper. The second part consists of description of the evaluation results of positioning accuracy, the genesis of the problem of selecting method for underwater positioning, and the mathematical description of the method of estimating the position coordinates using the EKF method by the fusion of measurements with on-board navigation and measurements obtained with the USBL system. The main part contains a description of experimental research. It consists of a simulation program of navigational parameter measurements carried out during the BAUV passage along the test section. Next, the article covers the determination of position coordinates on the basis of simulated parameters, using EKF and DR methods and the USBL system, which are then subjected to a comparative analysis of accuracy. The final part contains systemic conclusions justifying the desirability of applying the proposed fusion method of navigation parameters for the BAUV positioning. PMID:27537884
Krzysztof, Naus; Aleksander, Nowak
2016-08-15
The article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base Line) system. The problem of underwater positioning and the conceptual design of the BAUV navigation system constructed at the Naval Academy (Polish Naval Academy-PNA) are presented in the first part of the paper. The second part consists of description of the evaluation results of positioning accuracy, the genesis of the problem of selecting method for underwater positioning, and the mathematical description of the method of estimating the position coordinates using the EKF method by the fusion of measurements with on-board navigation and measurements obtained with the USBL system. The main part contains a description of experimental research. It consists of a simulation program of navigational parameter measurements carried out during the BAUV passage along the test section. Next, the article covers the determination of position coordinates on the basis of simulated parameters, using EKF and DR methods and the USBL system, which are then subjected to a comparative analysis of accuracy. The final part contains systemic conclusions justifying the desirability of applying the proposed fusion method of navigation parameters for the BAUV positioning.
SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hui, C; Robertson, D; Alsanea, F
2015-06-15
Purpose: The purpose of this work is to develop a geometric calibration method to accurately calculate physical distances within a liquid scintillator detector and to assess the accuracy, consistency, and robustness of proton beam range measurements when using a liquid scintillator detector system with the proposed geometric calibration process. Methods: We developed a geometric calibration procedure to accurately convert pixel locations in the camera frame into physical locations in the scintillator frame. To ensure accuracy, the geometric calibration was performed before each experiment. The liquid scintillator was irradiated with spot scanning proton beams of 94 energies in two deliveries. Amore » CCD camera was used to capture the two-dimensional scintillation light profile of each of the proton energies. An algorithm was developed to automatically calculate the proton range from the acquired images. The measured range was compared to the nominal range to assess the accuracy of the detector. To evaluate the robustness of the detector between each setup, the experiments were repeated on three different days. To evaluate the consistency of the measurements between deliveries, three sets of measurements were acquired for each experiment. Results: Using this geometric calibration procedure, the proton beam ranges measured using the liquid scintillator system were all within 0.3mm of the nominal range. The average difference between the measured and nominal ranges was −0.20mm. The delivery-to-delivery standard deviation of the proton range measurement was 0.04mm, and the setup-to-setup standard deviation of the measurement was 0.10mm. Conclusion: The liquid scintillator system can measure the range of all 94 beams in just two deliveries. With the proposed geometric calibration, it can measure proton range with sub-millimeter accuracy, and the measurements were shown to be consistent between deliveries and setups. Therefore, we conclude that the liquid scintillator system provides a reliable and convenient tool for proton range measurement. This project was supported in part by award number CA182450 from the National Cancer Institute.« less
Performance of a solar augmented heat pump
NASA Astrophysics Data System (ADS)
Bedinger, A. F. G.; Tomlinson, J. J.; Reid, R. L.; Chaffin, D. J.
Performance of a residential size solar augmented heat pump is reported for the 1979-1980 heating season. The facility located in Knoxville, Tennessee, has a measured heat load coefficient of 339.5 watt/C (644 BTU/hr- F). The solar augmented heat pump system consists of 7.4 cu m of one inch diameter crushed limestone. The heat pump is a nominal 8.8 KW (2 1/2 ton) high efficiency unit. The system includes electric resistance heaters to give the option of adding thermal energy to the pebble bed storage during utility off-peak periods, thus offering considerable load management capability. A 15 KW electric resistance duct heater is used to add thermal energy to the pebble bin as required during off-peak periods. Hourly thermal performance and on site weather data was taken for the period November 1, 1979, to April 13, 1980. Thermal performance data consists of heat flow summations for all modes of the system, pebble bed temperatures, and space temperature. Weather data consists of dry bulb temperature, dew point temperature, total global insolation (in the plane of the collector), and wind speed and direction. An error analysis was performed and the least accurate of the measurements was determined to be the heat flow at 5%. Solar system thermal performance factor was measured to be 8.77. The heat pump thermal performance factor was 1.64. Total system seasonal performance factor was measured to be 1.66. Using a modified version of TRNSYS, the thermal performance of this system was simulated. When simulation results were compared with data collected onsite, the predicted heat flow and power consumption generally were within experimental accuracy.
Fiber optic microsensor hydrogen leak detection system on Delta IV launch vehicle
NASA Astrophysics Data System (ADS)
Kazemi, Alex A.; Goepp, John W.; Larson, David B.; Wuestling, Mark E.
2008-04-01
This paper describes the successful development and test of a multipoint fiber optic hydrogen microsensors system during the static firing of an Evolved Expandable Launch Vehicle (EELV)/Delta's common booster core (CBC) rocket engine at NASA's Stennis Space Center. The hydrogen sensitive chemistry is fully reversible and has demonstrated a response to hydrogen gas in the range of 0% to 10% with a resolution of 0.1% and a response time of <=5 seconds measured at a gas flow rate of 1 cc/min. The system consisted of a reversible chemical interaction causing a change in reflective of a thin film of coated Palladium. The sensor using a passive element consisting of chemically reactive microcoatings deposited on the surface of a glass microlens, which is then bonded to an optical fiber. The system uses a multiplexing technique with a fiber optic driver-receiver consisting of a modulated LED source that is launched into the sensor, and photodiode detector that synchronously measures the reflected signal. The system incorporates a microprocessor to perform the data analysis and storage, as well as trending and set alarm function. The paper illustrates the sensor design and performance data under field deployment conditions.
Vélez-González, Heltie; Pradhan, Rohit; Weech-Maldonado, Robert
2011-01-01
Non-financial measures have found increasing acceptance in the business world--however, their application in the health care industry remains limited. The purpose of this article is to understand the influence of non-financial measures (efficiency, productivity, and quality) on the financial performance of for-profit system hospitals. The sample consists of 499 for-profit system hospitals in the United States from 1999 to 2002. Data analyzed include the American Hospital Association's Annual Survey, Medicare Cost Reports, Joint Commission's quality scores, and the Centers for Medicare & Medicaid Services' Hospital Case Mix Index. Dependent variables consist of financial measures (operating and total margins), while independent variables include measures of efficiency, productivity, and quality. Our results suggest the influence of non-financial performance measures on financial performance; occupancy rate positively influences financial performance while greater labor intensity may have negative implications for financial performance. In addition, we show that quality positively influences financial performance thereby offering a potential business case for quality. This result has important managerial and policy implications as it may incentivize capital and human resource investments required to improve hospital quality of care.
Interactions measurement payload for Shuttle
NASA Technical Reports Server (NTRS)
Guidice, D. A.; Pike, C. P.
1985-01-01
The Interactions Measurement Payload for Shuttle (IMPS) consisted of engineering experiments to determine the effects of the space environment on projected Air Force space systems. Measurements by IMPS on a polar-orbit Shuttle flight will lead to detailed knowledge of the interaction of the low-altitude polar-auroral environment on materials, equipment and technologies to be used in future large, high-power space systems. The results from the IMPS measurements will provide direct input to MIL-STD design guidelines and test standards that properly account for space-environment effects.
NASA Technical Reports Server (NTRS)
Abreu, Vincent J.; Hays, Paul B.; Barnes, John E.
1989-01-01
A high resolution lidar system was implemented to measure winds in the lower atmosphere. The wind speed along the line of sight was determined by measuring the Doppler shift of the aerosol backscattered laser signal. The system in its present configuration is stable, and behaves as indicated by theoretical simulations. This system was built to demonstrate the capabilities of the detector system as a prototype for a spaceborne lidar. The detector system investigated consisted of a plane Fabry-Perot etalon, and a 12-ring anode detector. This system is generically similar to the Fabry-Perot interferometer developed for passive wind measurements on board the Dynamics Explorer satellite. That this detector system performs well in a lidar configuration was demonstrated.
Wideband propagation measurement system using spread spectrum signaling and TDRS
NASA Technical Reports Server (NTRS)
Jenkins, Jeffrey D.; Fan, Yiping; Osborne, William P.
1995-01-01
In this paper, a wideband propagation measurement system, which consisted of a ground-based transmitter, a mobile receiver, and a data acquisition system, was constructed. This system has been employed in a study of the characteristics of different propagation environments, such as urban, suburban and rural areas, by using a pseudonoise spreading sequence transmitted over NASA's Tracking and Data Relay Satellite System. The hardware and software tests showed that it met overall system requirements and it was very robust during a 3-month-long outdoor data collection experiment.
ERIC Educational Resources Information Center
City Univ. of New York, Flushing, NY. Queens Coll.
This Teacher Education and Mathematics (TEAM) content module focuses on metric measurement. Topics addressed include decimal structure and prefixes, precision in measurement, reference measures, United States customary and metric systems, volume, area, and conversion. The module consists of: (1) an instructor's text; (2) an instructor's guide and…
21 CFR 866.5170 - Breast milk immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breast milk immunological test system. 866.5170... milk immunological test system. (a) Identification. A breast milk immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the breast milk proteins. (b...
21 CFR 866.5170 - Breast milk immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breast milk immunological test system. 866.5170... milk immunological test system. (a) Identification. A breast milk immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the breast milk proteins. (b...
21 CFR 866.5170 - Breast milk immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breast milk immunological test system. 866.5170... milk immunological test system. (a) Identification. A breast milk immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the breast milk proteins. (b...
21 CFR 866.5170 - Breast milk immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breast milk immunological test system. 866.5170... milk immunological test system. (a) Identification. A breast milk immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the breast milk proteins. (b...
Hui, CheukKai; Robertson, Daniel; Alsanea, Fahed; Beddar, Sam
2015-08-01
Accurate confirmation and verification of the range of spot scanning proton beams is crucial for correct dose delivery. Current methods to measure proton beam range using ionization chambers are either time-consuming or result in measurements with poor spatial resolution. The large-volume liquid scintillator detector allows real-time measurements of the entire dose profile of a spot scanning proton beam. Thus, liquid scintillator detectors are an ideal tool for measuring the proton beam range for commissioning and quality assurance. However, optical artefacts may decrease the accuracy of measuring the proton beam range within the scintillator tank. The purpose of the current study was to 1) develop a geometric calibration system to accurately calculate physical distances within the liquid scintillator detector, taking into account optical artefacts; and 2) assess the accuracy, consistency, and robustness of proton beam range measurement using the liquid scintillator detector with our geometric calibration system. The range of the proton beam was measured with the calibrated liquid scintillator system and was compared to the nominal range. Measurements were made on three different days to evaluate the setup robustness from day to day, and three sets of measurements were made for each day to evaluate the consistency from delivery to delivery. All proton beam ranges measured using the liquid scintillator system were within half a millimeter of the nominal range. The delivery-to-delivery standard deviation of the range measurement was 0.04 mm, and the day-to-day standard deviation was 0.10 mm. In addition to the accuracy and robustness demonstrated by these results when our geometric calibration system was used, the liquid scintillator system allowed the range of all 94 proton beams to be measured in just two deliveries, making the liquid scintillator detector a perfect tool for range measurement of spot scanning proton beams.
Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector
Hui, CheukKai; Robertson, Daniel; Alsanea, Fahed; Beddar, Sam
2016-01-01
Accurate confirmation and verification of the range of spot scanning proton beams is crucial for correct dose delivery. Current methods to measure proton beam range using ionization chambers are either time-consuming or result in measurements with poor spatial resolution. The large-volume liquid scintillator detector allows real-time measurements of the entire dose profile of a spot scanning proton beam. Thus, liquid scintillator detectors are an ideal tool for measuring the proton beam range for commissioning and quality assurance. However, optical artefacts may decrease the accuracy of measuring the proton beam range within the scintillator tank. The purpose of the current study was to 1) develop a geometric calibration system to accurately calculate physical distances within the liquid scintillator detector, taking into account optical artefacts; and 2) assess the accuracy, consistency, and robustness of proton beam range measurement using the liquid scintillator detector with our geometric calibration system. The range of the proton beam was measured with the calibrated liquid scintillator system and was compared to the nominal range. Measurements were made on three different days to evaluate the setup robustness from day to day, and three sets of measurements were made for each day to evaluate the consistency from delivery to delivery. All proton beam ranges measured using the liquid scintillator system were within half a millimeter of the nominal range. The delivery-to-delivery standard deviation of the range measurement was 0.04 mm, and the day-to-day standard deviation was 0.10 mm. In addition to the accuracy and robustness demonstrated by these results when our geometric calibration system was used, the liquid scintillator system allowed the range of all 94 proton beams to be measured in just two deliveries, making the liquid scintillator detector a perfect tool for range measurement of spot scanning proton beams. PMID:27274863
Direct measurements of temperature-dependent laser absorptivity of metal powders
Rubenchik, A.; Wu, S.; Mitchell, S.; ...
2015-08-12
Here, a compact system is developed to measure laser absorptivity for a variety of powder materials (metals, ceramics, etc.) with different powder size distributions and thicknesses. The measured results for several metal powders are presented. The results are consistent with those from ray tracing calculations.
Direct measurements of temperature-dependent laser absorptivity of metal powders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubenchik, A.; Wu, S.; Mitchell, S.
Here, a compact system is developed to measure laser absorptivity for a variety of powder materials (metals, ceramics, etc.) with different powder size distributions and thicknesses. The measured results for several metal powders are presented. The results are consistent with those from ray tracing calculations.
Exhaust-gas measurements from NASAs HYMETS arc jet.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Paul Albert
Arc-jet wind tunnels produce conditions simulating high-altitude hypersonic flight such as occurs upon entry of space craft into planetary atmospheres. They have traditionally been used to study flight in Earth's atmosphere, which consists mostly of nitrogen and oxygen. NASA is presently using arc jets to study entry into Mars' atmosphere, which consists of carbon dioxide and nitrogen. In both cases, a wide variety of chemical reactions take place among the gas constituents and with test articles placed in the flow. In support of those studies, we made measurements using a residual gas analyzer (RGA) that sampled the exhaust stream ofmore » a NASA arc jet. The experiments were conducted at the HYMETS arc jet (Hypersonic Materials Environmental Test System) located at the NASA Langley Research Center, Hampton, VA. This report describes our RGA measurements, which are intended to be used for model validation in combination with similar measurements on other systems.« less
Use of microstrip patch antennas in grain and pulverized materials permittivity measurement
El Sabbagh, M.A.; Ramahi, O.M.; Trabelsi, S.; Nelson, S.O.; Khan, L.
2003-01-01
A free-space microwave system developed for the measurement of the relative complex permittivity of granular materials and of pulverized materials was reported. The system consists of a transmitting antenna and a receiving antenna separated by a space filled by the sample to be characterized and a network analyzer for transmission measurement. The receiving antenna was mounted on a movable plate, which gives the flexibility of having different sample thicknesses.
NASA Astrophysics Data System (ADS)
Zhao, Ziyue; Gan, Xiaochuan; Zou, Zhi; Ma, Liqun
2018-01-01
The dynamic envelope measurement plays very important role in the external dimension design for high-speed train. Recently there is no digital measurement system to solve this problem. This paper develops an optoelectronic measurement system by using monocular digital camera, and presents the research of measurement theory, visual target design, calibration algorithm design, software programming and so on. This system consists of several CMOS digital cameras, several luminous targets for measuring, a scale bar, data processing software and a terminal computer. The system has such advantages as large measurement scale, high degree of automation, strong anti-interference ability, noise rejection and real-time measurement. In this paper, we resolve the key technology such as the transformation, storage and calculation of multiple cameras' high resolution digital image. The experimental data show that the repeatability of the system is within 0.02mm and the distance error of the system is within 0.12mm in the whole workspace. This experiment has verified the rationality of the system scheme, the correctness, the precision and effectiveness of the relevant methods.
NASA Technical Reports Server (NTRS)
DeYoung, Russell J.; Goldschmidt, Soenke
1999-01-01
Measurements of global atmosphere ozone concentrations call for flexible lidar systems that can be operated from an unpiloted atmospheric vehicle (UAV) to reduce the cost of measurement missions. A lidar receiver system consisting of a fiber-optic-coupled telescope has been designed and tested for this purpose. The system weight is 13 kg and its volume of 0.06 m 3 would fit into the payload compartment of a Perseus B UAV. The optical efficiency of the telescope is 37 percent at 288 nm and 64 percent at 300 nm. Atmospheric measurements with a DIAL laser system have been performed, and the measured ozone density has matched the data from ozonesondes to an altitude of 7 km.
Eltoukhy, Moataz; Kelly, Adam; Kim, Chang-Young; Jun, Hyung-Pil; Campbell, Richard; Kuenze, Christopher
2016-01-01
Cost effective, quantifiable assessment of lower extremity movement represents potential improvement over standard tools for evaluation of injury risk. Ten healthy participants completed three trials of a drop jump, overhead squat, and single leg squat task. Peak hip and knee kinematics were assessed using an 8 camera BTS Smart 7000DX motion analysis system and the Microsoft Kinect® camera system. The agreement and consistency between both uncorrected and correct Kinect kinematic variables and the BTS camera system were assessed using interclass correlations coefficients. Peak sagittal plane kinematics measured using the Microsoft Kinect® camera system explained a significant amount of variance [Range(hip) = 43.5-62.8%; Range(knee) = 67.5-89.6%] in peak kinematics measured using the BTS camera system. Across tasks, peak knee flexion angle and peak hip flexion were found to be consistent and in agreement when the Microsoft Kinect® camera system was directly compared to the BTS camera system but these values were improved following application of a corrective factor. The Microsoft Kinect® may not be an appropriate surrogate for traditional motion analysis technology, but it may have potential applications as a real-time feedback tool in pathological or high injury risk populations.
Fluid injection device for high-pressure systems
NASA Technical Reports Server (NTRS)
Copeland, E. J.; Ward, J. B.
1970-01-01
Screw activated device, consisting of a compressor, shielded replaceable ampules, a multiple-element rubber gland, and a specially constructed fluid line fitting, injects measured amounts of fluids into a pressurized system. It is sturdy and easily manipulated.
21 CFR 866.5370 - Cohn fraction V immuno-logical test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... test system is a device that consists of or measures that fraction of plasma containing predominantly albumin (a plasma protein). This test aids in the diagnosis of diseases where albumin levels may be...
21 CFR 866.5370 - Cohn fraction V immuno-logical test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... test system is a device that consists of or measures that fraction of plasma containing predominantly albumin (a plasma protein). This test aids in the diagnosis of diseases where albumin levels may be...
21 CFR 866.5370 - Cohn fraction V immuno-logical test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... test system is a device that consists of or measures that fraction of plasma containing predominantly albumin (a plasma protein). This test aids in the diagnosis of diseases where albumin levels may be...
21 CFR 866.5370 - Cohn fraction V immuno-logical test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... test system is a device that consists of or measures that fraction of plasma containing predominantly albumin (a plasma protein). This test aids in the diagnosis of diseases where albumin levels may be...
21 CFR 866.5370 - Cohn fraction V immuno-logical test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... test system is a device that consists of or measures that fraction of plasma containing predominantly albumin (a plasma protein). This test aids in the diagnosis of diseases where albumin levels may be...
A Vision-Based Dynamic Rotational Angle Measurement System for Large Civil Structures
Lee, Jong-Jae; Ho, Hoai-Nam; Lee, Jong-Han
2012-01-01
In this paper, we propose a vision-based rotational angle measurement system for large-scale civil structures. Despite the fact that during the last decade several rotation angle measurement systems were introduced, they however often required complex and expensive equipment. Therefore, alternative effective solutions with high resolution are in great demand. The proposed system consists of commercial PCs, commercial camcorders, low-cost frame grabbers, and a wireless LAN router. The calculation of rotation angle is obtained by using image processing techniques with pre-measured calibration parameters. Several laboratory tests were conducted to verify the performance of the proposed system. Compared with the commercial rotation angle measurement, the results of the system showed very good agreement with an error of less than 1.0% in all test cases. Furthermore, several tests were conducted on the five-story modal testing tower with a hybrid mass damper to experimentally verify the feasibility of the proposed system. PMID:22969348
A vision-based dynamic rotational angle measurement system for large civil structures.
Lee, Jong-Jae; Ho, Hoai-Nam; Lee, Jong-Han
2012-01-01
In this paper, we propose a vision-based rotational angle measurement system for large-scale civil structures. Despite the fact that during the last decade several rotation angle measurement systems were introduced, they however often required complex and expensive equipment. Therefore, alternative effective solutions with high resolution are in great demand. The proposed system consists of commercial PCs, commercial camcorders, low-cost frame grabbers, and a wireless LAN router. The calculation of rotation angle is obtained by using image processing techniques with pre-measured calibration parameters. Several laboratory tests were conducted to verify the performance of the proposed system. Compared with the commercial rotation angle measurement, the results of the system showed very good agreement with an error of less than 1.0% in all test cases. Furthermore, several tests were conducted on the five-story modal testing tower with a hybrid mass damper to experimentally verify the feasibility of the proposed system.
Interactive stereo electron microscopy enhanced with virtual reality
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bethel, E.Wes; Bastacky, S.Jacob; Schwartz, Kenneth S.
2001-12-17
An analytical system is presented that is used to take measurements of objects perceived in stereo image pairs obtained from a scanning electron microscope (SEM). Our system operates by presenting a single stereo view that contains stereo image data obtained from the SEM, along with geometric representations of two types of virtual measurement instruments, a ''protractor'' and a ''caliper''. The measurements obtained from this system are an integral part of a medical study evaluating surfactant, a liquid coating the inner surface of the lung which makes possible the process of breathing. Measurements of the curvature and contact angle of submicronmore » diameter droplets of a fluorocarbon deposited on the surface of airways are performed in order to determine surface tension of the air/liquid interface. This approach has been extended to a microscopic level from the techniques of traditional surface science by measuring submicrometer rather than millimeter diameter droplets, as well as the lengths and curvature of cilia responsible for movement of the surfactant, the airway's protective liquid blanket. An earlier implementation of this approach for taking angle measurements from objects perceived in stereo image pairs using a virtual protractor is extended in this paper to include distance measurements and to use a unified view model. The system is built around a unified view model that is derived from microscope-specific parameters, such as focal length, visible area and magnification. The unified view model ensures that the underlying view models and resultant binocular parallax cues are consistent between synthetic and acquired imagery. When the view models are consistent, it is possible to take measurements of features that are not constrained to lie within the projection plane. The system is first calibrated using non-clinical data of known size and resolution. Using the SEM, stereo image pairs of grids and spheres of known resolution are created to calibrate the measurement system. After calibration, the system is used to take distance and angle measurements of clinical specimens.« less
Ground-Based Lidar for Atmospheric Boundary Layer Ozone Measurements
NASA Technical Reports Server (NTRS)
Kuang, Shi; Newchurch, Michael J.; Burris, John; Liu, Xiong
2013-01-01
Ground-based lidars are suitable for long-term ozone monitoring as a complement to satellite and ozonesonde measurements. However, current ground-based lidars are unable to consistently measure ozone below 500 m above ground level (AGL) due to both engineering issues and high retrieval sensitivity to various measurement errors. In this paper, we present our instrument design, retrieval techniques, and preliminary results that focus on the high-temporal profiling of ozone within the atmospheric boundary layer (ABL) achieved by the addition of an inexpensive and compact mini-receiver to the previous system. For the first time, to the best of our knowledge, the lowest, consistently achievable observation height has been extended down to 125 m AGL for a ground-based ozone lidar system. Both the analysis and preliminary measurements demonstrate that this lidar measures ozone with a precision generally better than 10% at a temporal resolution of 10 min and a vertical resolution from 150 m at the bottom of the ABL to 550 m at the top. A measurement example from summertime shows that inhomogeneous ozone aloft was affected by both surface emissions and the evolution of ABL structures.
NASA Astrophysics Data System (ADS)
Hadaway, James B.; Wells, Conrad; Olczak, Gene; Waldman, Mark; Whitman, Tony; Cosentino, Joseph; Connolly, Mark; Chaney, David; Telfer, Randal
2016-07-01
The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse and fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment and phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development and spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software and procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate and efficient cryogenic testing of the JWST flight telescope.
NASA Technical Reports Server (NTRS)
Hadaway, James B.; Wells, Conrad; Olczak, Gene; Waldman, Mark; Whitman, Tony; Cosentino, Joseph; Connolly, Mark; Chaney, David; Telfer, Randal
2016-01-01
The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.
An ultrasound wearable system for the monitoring and acceleration of fracture healing in long bones.
Protopappas, Vasilios C; Baga, Dina A; Fotiadis, Dimitrios I; Likas, Aristidis C; Papachristos, Athanasios A; Malizos, Konstantinos N
2005-09-01
An ultrasound wearable system for remote monitoring and acceleration of the healing process in fractured long bones is presented. The so-called USBone system consists of a pair of ultrasound transducers, implanted into the fracture region, a wearable device and a centralized unit. The wearable device is responsible to carry out ultrasound measurements using the axial-transmission technique and initiate therapy sessions of low-intensity pulsed ultrasound. The acquired measurements and other data are wirelessly transferred from the patient-site to the centralized unit, which is located in a clinical setting. The evaluation of the system on an animal tibial osteotomy model is also presented. A dataset was constructed for monitoring purposes consisting of serial ultrasound measurements, follow-up radiographs, quantitative computed tomography-based densitometry and biomechanical data. The animal study demonstrated the ability of the system to collect ultrasound measurements in an effective and reliable fashion and participating orthopaedic surgeons accepted the system for future clinical application. Analysis of the acquired measurements showed that the pattern of evolution of the ultrasound velocity through healing bones over the postoperative period monitors a dynamic healing process. Furthermore, the ultrasound velocity of radiographically healed bones returns to 80% of the intact bone value, whereas the correlation coefficient of the velocity with the material and mechanical properties of the healing bone ranges from 0.699 to 0.814. The USBone system constitutes the first telemedicine system for the out-hospital management of patients sustained open fractures and treated with external fixation devices.
Comparative Effects of Antihistamines on Aircrew Mission Effectiveness under Sustained Operations
1992-06-01
measures consist mainly of process measures. Process measures are measures of activities used to accomplish the mission and produce the final results...They include task completion times and response variability, and information processing rates as they relate to unique task assignment. Performance...contains process measures that assess the Individual contributions of hardware/software and human components to overall system performance. Measures
Code of Federal Regulations, 2013 CFR
2013-07-01
... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...
Code of Federal Regulations, 2014 CFR
2014-07-01
... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...
Code of Federal Regulations, 2012 CFR
2012-07-01
... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...
Sensitivity of measurement-based purification processes to inner interactions
NASA Astrophysics Data System (ADS)
Militello, Benedetto; Napoli, Anna
2018-02-01
The sensitivity of a repeated measurement-based purification scheme to additional undesired couplings is analyzed, focusing on the very simple and archetypical system consisting of two two-level systems interacting with a repeatedly measured one. Several regimes are considered and in the strong coupling limit (i.e., when the coupling constant of the undesired interaction is very large) the occurrence of a quantum Zeno effect is proven to dramatically jeopardize the efficiency of the purification process.
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
21 CFR 866.5590 - Lipoprotein X immunolog-ical test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Lipoprotein X immunolog-ical test system. 866.5590... Lipoprotein X immunolog-ical test system. (a) Identification. A lipoprotein X immunological test system is a device that consists of the reagents used to measure by immunochemical techniques lipoprotein X (a high...
Studies on system and measuring method of far-field beam divergency in near field by Ronchi ruling
NASA Astrophysics Data System (ADS)
Zhou, Chenbo; Yang, Li; Ma, Wenli; Yan, Peiying; Fan, Tianquan; He, Shangfeng
1996-10-01
Up to now, as large as seven times of Rayleigh-range or more is needed in measuring the far-field Gaussian beam divergency. This method is very inconvenient for the determination of the output beam divergency of the industrial product such as He-Ne lasers and the measuring unit will occupy a large space. The measurement and the measuring accuracy will be greatly influenced by the environment. Application of the Ronchi ruling to the measurement of far-field divergency of Gaussian beam in near-field is analyzed in the paper. The theoretical research and the experiments show that this measuring method is convenient in industrial application. The measuring system consists of a precision mechanical unit which scans Gaussian beam with a microdisplaced Ronchi ruling, a signal sampling system, a single-chip microcomputer data processing system and an electronic unit with microprinter output. The characteristics of the system is stable and the repeatability errors of the system are low. The spot size and far-field divergency of visible Gaussian laser beam can be measured with the system.
Campo, Xandra; Méndez, Roberto; Embid, Miguel; Ortego, Alberto; Novo, Manuel; Sanz, Javier
2018-05-01
Neutron fields inside and outside the independent spent fuel storage installation of Trillo Nuclear Power Plant are characterized exhaustively in terms of neutron spectra and ambient dose equivalent, measured by Bonner sphere system and LB6411 monitor. Measurements are consistent with storage casks and building shield characteristics, and also with casks distribution inside the building. Outer values at least five times lower than dose limit for free access area are found. Measurements with LB6411 and spectrometer are consistent with each other. Copyright © 2018 Elsevier Ltd. All rights reserved.
Optical 3D-coordinate measuring system using structured light
NASA Astrophysics Data System (ADS)
Schreiber, Wolfgang; Notni, Gunther; Kuehmstedt, Peter; Gerber, Joerg; Kowarschik, Richard M.
1996-09-01
The paper is aimed at the description of an optical shape measuring technique based on a consistent principle using fringe projection technique. We demonstrate a real 3D- coordinate measuring system where the sale of coordinates is given only by the illumination-structures. This method has the advantages that the aberration of the observing system and the depth-dependent imaging scale have no influence on the measuring accuracy and, moreover, the measurements are independent of the position of the camera with respect to the object under test. Furthermore, it is shown that the influence of specular effects of the surface on the measuring result can be eliminated. Moreover, we developed a very simple algorithm to calibrate the measuring system. The measuring examples show that a measuring accuracy of 10-4 (i.e. 10 micrometers ) within an object volume of 100 X 100 X 70 mm3 is achievable. Furthermore, it is demonstrated that the set of coordinate values can be processed in CNC- and CAD-systems.
FPGA-based real-time embedded system for RISS/GPS integrated navigation.
Abdelfatah, Walid Farid; Georgy, Jacques; Iqbal, Umar; Noureldin, Aboelmagd
2012-01-01
Navigation algorithms integrating measurements from multi-sensor systems overcome the problems that arise from using GPS navigation systems in standalone mode. Algorithms which integrate the data from 2D low-cost reduced inertial sensor system (RISS), consisting of a gyroscope and an odometer or wheel encoders, along with a GPS receiver via a Kalman filter has proved to be worthy in providing a consistent and more reliable navigation solution compared to standalone GPS receivers. It has been also shown to be beneficial, especially in GPS-denied environments such as urban canyons and tunnels. The main objective of this paper is to narrow the idea-to-implementation gap that follows the algorithm development by realizing a low-cost real-time embedded navigation system capable of computing the data-fused positioning solution. The role of the developed system is to synchronize the measurements from the three sensors, relative to the pulse per second signal generated from the GPS, after which the navigation algorithm is applied to the synchronized measurements to compute the navigation solution in real-time. Employing a customizable soft-core processor on an FPGA in the kernel of the navigation system, provided the flexibility for communicating with the various sensors and the computation capability required by the Kalman filter integration algorithm.
FPGA-Based Real-Time Embedded System for RISS/GPS Integrated Navigation
Abdelfatah, Walid Farid; Georgy, Jacques; Iqbal, Umar; Noureldin, Aboelmagd
2012-01-01
Navigation algorithms integrating measurements from multi-sensor systems overcome the problems that arise from using GPS navigation systems in standalone mode. Algorithms which integrate the data from 2D low-cost reduced inertial sensor system (RISS), consisting of a gyroscope and an odometer or wheel encoders, along with a GPS receiver via a Kalman filter has proved to be worthy in providing a consistent and more reliable navigation solution compared to standalone GPS receivers. It has been also shown to be beneficial, especially in GPS-denied environments such as urban canyons and tunnels. The main objective of this paper is to narrow the idea-to-implementation gap that follows the algorithm development by realizing a low-cost real-time embedded navigation system capable of computing the data-fused positioning solution. The role of the developed system is to synchronize the measurements from the three sensors, relative to the pulse per second signal generated from the GPS, after which the navigation algorithm is applied to the synchronized measurements to compute the navigation solution in real-time. Employing a customizable soft-core processor on an FPGA in the kernel of the navigation system, provided the flexibility for communicating with the various sensors and the computation capability required by the Kalman filter integration algorithm. PMID:22368460
SHMS Hodoscopes and Time of Flight System
NASA Astrophysics Data System (ADS)
Craycraft, Kayla; Malace, Simona
2017-09-01
As part of the Thomas Jefferson National Accelerator Facility's (Jefferson Lab) upgrade from 6 GeV to 12 GeV, a new magnetic focusing spectrometer, the Super High Momentum Spectrometer (SHMS), was installed in experimental Hall C. The detector stack consists of horizontal drift chambers for tracking, gas Cerenkov and Aerogel detectors and a lead glass calorimeter for particle identification. A hodoscope system consisting of three planes of scintillator detectors (constructed by James Madison University) and one plane of quartz bars (built by North Carolina A&T State University) is used for triggering and time of flight measurements. This presentation consists of discussion of the installation, calibration, and characterization of the detectors used in this Time of Flight system. James Madison University, North Carolina A&T State University.
NASA Astrophysics Data System (ADS)
Murphy, J. P.; Gheorghiu, N. N.; Bullard, T.; Haugan, T.; Sumption, M. D.; Majoros, M.; Collings, E. W.
2017-09-01
A new facility for the measurement of AC loss in superconductors at high dB/dt has been developed. The test device has a spinning rotor consisting of permanent magnets arranged in a Halbach array; the sample, positioned outside of this, is exposed to a time varying AC field with a peak radial field of 0.566 T. At a rotor speed of 3600 RPM the frequency of the AC field is 240 Hz, the radial dB/dt is 543 T/s and the tangential dB/dt is 249 T/s. Loss is measured using nitrogen boiloff from a double wall calorimeter feeding a gas flow meter. The system is calibrated using power from a known resistor. YBCO tape losses were measured in the new device and compared to the results from a solenoidal magnet AC loss system measurement of the same samples (in this latter case measurements were limited to a field of amplitude 0.1 T and a dB/dt of 100 T/s). Solenoidal magnet system AC loss measurements taken on a YBCO sample agreed with the Brandt loss expression associated with a 0-0.1 T Ic of 128 A. Subsequently, losses for two more YBCO tapes nominally identical to the first were individually measured in this spinning magnet calorimeter (SMC) machine with a Bmax of 0.566 T and dB/dt of up to 272 T/s. The losses, compared to a simplified version of the Brandt expression, were consistent with the average Ic expected for the tape in the 0-0.5 T range at 77 K. The eddy current contribution was consistent with a 77 K residual resistance ratio, RR, of 4.0. The SMC results for these samples agreed to within 5%. Good agreement was also obtained between the results of the SMC AC loss measurement and the solenoidal magnet AC loss measurement on the same samples.
NASA Astrophysics Data System (ADS)
Raimondi, L.; Azetsu-Scott, K.; Wallace, D.
2016-02-01
This work assesses the internal consistency of ocean carbon dioxide through the comparison of discrete measurements and calculated values of four analytical parameters of the inorganic carbon system: Total Alkalinity (TA), Dissolved Inorganic Carbon (DIC), pH and Partial Pressure of CO2 (pCO2). The study is based on 486 seawater samples analyzed for TA, DIC and pH and 86 samples for pCO2 collected during the 2014 Cruise along the AR7W line in Labrador Sea. The internal consistency has been assessed using all combinations of input parameters and eight sets of thermodynamic constants (K1, K2) in calculating each parameter through the CO2SYS software. Residuals of each parameter have been calculated as the differences between measured and calculated values (reported as ΔTA, ΔDIC, ΔpH and ΔpCO2). Although differences between the selected sets of constants were observed, the largest were obtained using different pairs of input parameters. As expected the couple pH-pCO2 produced to poorest results, suggesting that measurements of either TA or DIC are needed to define the carbonate system accurately and precisely. To identify signature of organic alkalinity we isolated the residuals in the bloom area. Therefore only ΔTA from surface waters (0-30 m) along the Greenland side of the basin were selected. The residuals showed that no measured value was higher than calculations and therefore we could not observe presence of organic bases in the shallower water column. The internal consistency in characteristic water masses of Labrador Sea (Denmark Strait Overflow Water, North East Atlantic Deep Water, Newly-ventilated Labrador Sea Water, Greenland and Labrador Shelf waters) will also be discussed.
[Quality assurance in diagnostic radiology using an automated system. Experience and results].
Princivalli, M; Stea, L; Ordóñez, P L; Bussoli, L; Marchetti, C
1995-05-01
The authors report their personal experience with the use of an integrated quality control system in the radiology department. The system we used was the RTI DIGI-X Plus, a Swedish-made product, allowing a wide range of parameters to be measured on diagnostic X-ray units for general radiography, mammography and fluoroscopy. Data can be retrieved with a minimum number of measurements. The "oRTIgo" software improves the quality assurance system and ensures document compliance with international recommendations. The equipment consists of a detector unit, a processor and a display unit. The detector consists of a rotating holder with 12 combinations of metal filters of various thickness mounted in front of two photo-diodes covered with identical X-ray intensifying gadoliniumoxysulfide screens. This unit is connected to a data acquisition system controlled by a microcomputer. Peak tube voltage and total tube filtration are derived from the ratio of detector signals. The relationship between this ratio and the measured quantity is determined by a calibration procedure. Furthermore, exposure time "mAs" value, "mAs" linearity and exposure (or kerma in air) can be measured. Digital storage can be performed and input signals displayed. A serial interface is used to communicate with a PC for QC management purposes. An error propagation model is used to determine the inaccuracy of peak tube voltage measurements. With the DIGI-X Plus system, measurements can be carried out in a shorter time and the stored data reprocessed later on. After QA testing on 20 X-ray units in the radiology department, in vivo doses were measured using a TLD Harshaw 100 on 46 randomly selected patients undergoing chest examinations. The results are reported and analyzed following the NRPB protocol and show high agreement with the recommended values.
Performance monitor system functional simulator, environmental data, orbiter 101(HFT)
NASA Technical Reports Server (NTRS)
Parker, F. W.
1974-01-01
Information concerning the environment component of the space shuttle performance monitor system simulator (PMSS) and those subsystems operational on the shuttle orbiter 101 used for horizontal flight test (HFT) is provided, along with detailed data for the shuttle performance monitor system (PMS) whose software requirements evolve from three basic PMS functions: (1) fault detection and annunciation; (2) subsystem measurement management; and (3) subsystem configuration management. Information relative to the design and operation of Orbiter systems for HFT is also presented, and the functional paths are identified to the lowest level at which the crew can control the system functions. Measurement requirements are given which are necessary to adequately monitor the health status of the system. PMS process requirements, relative to the measurements which are necessary for fault detection and annunciation of a failed functional path, consist of measurement characteristics, tolerance limits, precondition tests, and correlation measurements.
NASA Technical Reports Server (NTRS)
Davidson, Frederic M.; Field, Christopher T.; Sun, Xiaoli
1996-01-01
We report here the design and the performance measurements of the breadboard receiver of the Geoscience Laser Altimeter System (GLAS). The measured ranging accuracy was better than 2 cm and 10 cm for 5 ns and 30 ns wide received laser pulses under the expected received signal level, which agreed well with the theoretical analysis. The measured receiver sensitivity or the link margin was also consistent with the theory. The effects of the waveform digitizer sample rate and resolution were also measured.
MICROFABRICATED ELECTROCHEMICAL ANALYSIS SYSTEM FOR HEAVY METAL DETECTION. (R825511C047)
A low power, hand-held system has been developed for the measurement of heavy metal ions in aqueous solutions. The system consists of an electrode array sensor, a high performance single chip potentiostat and a microcontroller circuit. The sensor is a microfabricated array of ...
48 CFR 2807.103-70 - Other officials' responsibilities.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., requirements personnel consider the use of: (1) The metric system of measurement consistent with 15 U.S.C. 2205... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Other officials' responsibilities. 2807.103-70 Section 2807.103-70 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE...
48 CFR 2807.103-70 - Other officials' responsibilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., requirements personnel consider the use of: (1) The metric system of measurement consistent with 15 U.S.C. 2205... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Other officials' responsibilities. 2807.103-70 Section 2807.103-70 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE...
48 CFR 2807.103-70 - Other officials' responsibilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., requirements personnel consider the use of: (1) The metric system of measurement consistent with 15 U.S.C. 2205... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Other officials' responsibilities. 2807.103-70 Section 2807.103-70 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE...
48 CFR 2807.103-70 - Other officials' responsibilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., requirements personnel consider the use of: (1) The metric system of measurement consistent with 15 U.S.C. 2205... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Other officials' responsibilities. 2807.103-70 Section 2807.103-70 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE...
48 CFR 2807.103-70 - Other officials' responsibilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., requirements personnel consider the use of: (1) The metric system of measurement consistent with 15 U.S.C. 2205... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Other officials' responsibilities. 2807.103-70 Section 2807.103-70 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE...
Preliminary design package for Sunspot Domestic Hot Water Heating System
NASA Technical Reports Server (NTRS)
1976-01-01
The design review includes a drawing list, auto-control logic, measurement definitions, and other document pertaining to the solar heated prototype hot water systems and two heat exchangers. The hot water systems consist of the following subsystems: collector, storage, control transport, auxiliary energy, and site data acquisition.
Virtual performer: single camera 3D measuring system for interaction in virtual space
NASA Astrophysics Data System (ADS)
Sakamoto, Kunio; Taneji, Shoto
2006-10-01
The authors developed interaction media systems in the 3D virtual space. In these systems, the musician virtually plays an instrument like the theremin in the virtual space or the performer plays a show using the virtual character such as a puppet. This interactive virtual media system consists of the image capture, measuring performer's position, detecting and recognizing motions and synthesizing video image using the personal computer. In this paper, we propose some applications of interaction media systems; a virtual musical instrument and superimposing CG character. Moreover, this paper describes the measuring method of the positions of the performer, his/her head and both eyes using a single camera.
NASA Astrophysics Data System (ADS)
Zemánek, Ivan; Havlíček, Václav
2006-09-01
A new universal control and measuring system for classic and amorphous soft magnetic materials single/on-line strip testing has been developed at the Czech Technical University in Prague. The measuring system allows to measure magnetization characteristic and specific power losses of different tested materials (strips) at AC magnetization of arbitrary magnetic flux density waveform at wide range of frequencies 20 Hz-20 kHz. The measuring system can be used for both single strip testing in laboratories and on-line strip testing during the production process. The measuring system is controlled by two-stage master-slave control system consisting of the external PC (master) completed by three special A/D measuring plug-in boards, and local executing control unit (slave) with one-chip microprocessor 8051, connected with PC by the RS232 serial line. The "user friendly" powerful control software implemented on the PC and the effective program code for the microprocessor give possibility for full automatic measurement with high measuring power and high measuring accuracy.
Combinations of Earth Orientation Measurements: SPACE2001, COMB2001, and POLE2001
NASA Technical Reports Server (NTRS)
Gross, Richard S.
2002-01-01
Independent Earth-orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the global positioning system have been combined using a Kalman filter. The resulting combined Earth-orientation series, SPACE2001, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28.0, 1976 to January 19.0, 2002 at daily intervals. The space-geodetic measurements used to generate SPACE2001 have been combined with optical astrometric measurements to form two additional combined Earth-orientation series: (1) COMB2001, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20.0, 1962 to January 15.0, 2002 at five-day intervals, and (2) POLE2001, consisting of values and uncertainties for polar motion and its rates that span from January 20, 1900 to December 21, 2001 at 30.4375-day intervals.
Characteristics on electodynamic suspension simulator with HTS levitation magnet
NASA Astrophysics Data System (ADS)
Lee, J.; Bae, D. K.; Sim, K.; Chung, Y. D.; Lee, Y.-S.
2009-10-01
High- Tc superconducting (HTSC) electrodynamic suspension (EDS) system basically consists of the HTSC levitation magnet and the ground conductor. The levitation force of EDS system is forms by the interaction between the moving magnetic field produced by the onboard levitation magnet and the induced magnetic field produced by eddy current in the ground conductor. This paper deals with the characteristics of the EDS simulators with high- Tc superconducting (HTS) levitation magnet. Two EDS simulator systems, rotating type EDS simulator and static type EDS simulator, were studied in this paper. The rotating type EDS simulator consists of a HTS levitation magnet and a 1.5 m diameter rotating ground conductor, a motor, the supporting structure and force measuring devices. In the static type EDS simulator, instead of moving magnetic field, AC current was applied to the fixed HTS levitation magnet to induce the eddy current. The static type EDS simulator consists of a HTS levitation magnet, a ground conductor, force measuring devices and supporting structure. The double-pancake type HTSC levitation magnet was designed, manufactured and tested in the EDS simulator.
NASA Technical Reports Server (NTRS)
Klein, R. H.; Mcruer, D. T.; Weir, D.
1975-01-01
A maneuver complex and related performance measures used to evaluate driver/vehicle system responses as effected by variations in the directional response characteristics of passenger cars are described. The complex consists of normal and emergency maneuvers (including random and discrete disturbances) which, taken as a whole, represent all classes of steering functions and all modes of driver response behavior. Measures of driver/vehicle system response and performance in regulation tasks included direct describing function measurements and rms yaw velocity. In transient maneuvers, measures such as steering activity and cone strikes were used.
Ultrahigh-density sub-10 nm nanowire array formation via surface-controlled phase separation.
Tian, Yuan; Mukherjee, Pinaki; Jayaraman, Tanjore V; Xu, Zhanping; Yu, Yongsheng; Tan, Li; Sellmyer, David J; Shield, Jeffrey E
2014-08-13
We present simple, self-assembled, and robust fabrication of ultrahigh density cobalt nanowire arrays. The binary Co-Al and Co-Si systems phase-separate during physical vapor deposition, resulting in Co nanowire arrays with average diameter as small as 4.9 nm and nanowire density on the order of 10(16)/m(2). The nanowire diameters were controlled by moderating the surface diffusivity, which affected the lateral diffusion lengths. High resolution transmission electron microscopy reveals that the Co nanowires formed in the face-centered cubic structure. Elemental mapping showed that in both systems the nanowires consisted of Co with undetectable Al or Si and that the matrix consisted of Al with no distinguishable Co in the Co-Al system and a mixture of Si and Co in the Co-Si system. Magnetic measurements clearly indicate anisotropic behavior consistent with shape anisotropy. The dynamics of nanowire growth, simulated using an Ising model, is consistent with the experimental phase and geometry of the nanowires.
NASA Astrophysics Data System (ADS)
Mbanjwa, Mesuli B.; Chen, Hao; Fourie, Louis; Ngwenya, Sibusiso; Land, Kevin
2014-06-01
Multiplexed or parallelised droplet microfluidic systems allow for increased throughput in the production of emulsions and microparticles, while maintaining a small footprint and utilising minimal ancillary equipment. The current paper demonstrates the design and fabrication of a multiplexed microfluidic system for producing biocatalytic microspheres. The microfluidic system consists of an array of 10 parallel microfluidic circuits, for simultaneous operation to demonstrate increased production throughput. The flow distribution was achieved using a principle of reservoirs supplying individual microfluidic circuits. The microfluidic devices were fabricated in poly (dimethylsiloxane) (PDMS) using soft lithography techniques. The consistency of the flow distribution was determined by measuring the size variations of the microspheres produced. The coefficient of variation of the particles was determined to be 9%, an indication of consistent particle formation and good flow distribution between the 10 microfluidic circuits.
Safer bridge railings, volume 1 summary report.
DOT National Transportation Integrated Search
1984-06-01
This study consisted of strength analyses of five in-service bridge railing systems, thirty full-scale vehicle crash tests on those railing systems and on a load measuring wall, the development of recommended design guidelines and deve1opment of reco...
Hakim, B M; Beard, B B; Davis, C C
2018-01-01
Specific absorption rate (SAR) measurements require accurate calculations of the dielectric properties of tissue-equivalent liquids and associated calibration of E-field probes. We developed a precise tissue-equivalent dielectric measurement and E-field probe calibration system. The system consists of a rectangular waveguide, electric field probe, and data control and acquisition system. Dielectric properties are calculated using the field attenuation factor inside the tissue-equivalent liquid and power reflectance inside the waveguide at the air/dielectric-slab interface. Calibration factors were calculated using isotropicity measurements of the E-field probe. The frequencies used are 900 MHz and 1800 MHz. The uncertainties of the measured values are within ±3%, at the 95% confidence level. Using the same waveguide for dielectric measurements as well as calibrating E-field probes used in SAR assessments eliminates a source of uncertainty. Moreover, we clearly identified the system parameters that affect the overall uncertainty of the measurement system. PMID:29520129
A measurement system for the atmospheric trace gases CH4 and CO
NASA Technical Reports Server (NTRS)
Condon, E. P.
1977-01-01
A system for measuring ambient clean air levels of the atmospheric trace gases methane and carbon monoxide is described. The analytical method consists of a gas chromatographic technique that incorporates sample preconcentration with catalytic conversion of CO to CH4 and subsequent flame ionization detection of these gases. The system has sufficient sensitivity and repeatability to make the precise measurements required to establish concentration profiles for CO and CH4 in the planetary boundary layer. A discussion of the bottle sampling program being conducted to obtain the samples for the concentration profiles is also presented.
Tevatron beam position monitor upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolbers, Stephen; Banerjee, B.; Barker, B.
2005-05-01
The Tevatron Beam Position Monitor (BPM) readout electronics and software have been upgraded to improve measurement precision, functionality and reliability. The original system, designed and built in the early 1980's, became inadequate for current and future operations of the Tevatron. The upgraded system consists of 960 channels of new electronics to process analog signals from 240 BPMs, new front-end software, new online and controls software, and modified applications to take advantage of the improved measurements and support the new functionality. The new system reads signals from both ends of the existing directional stripline pickups to provide simultaneous proton and antiprotonmore » position measurements. Measurements using the new system are presented that demonstrate its improved resolution and overall performance.« less
The measurement of the ground wind structure at Wallops Island
NASA Technical Reports Server (NTRS)
Tielman, H. W.
1981-01-01
The mean and turbulence characteristics of the surface wind measured near the Atlantic coast were measured. The experimental data were acquired from a 76 meter tall instrumented micrometeorological tower. Mean wind and turbulence measurements were made with two types of instrumentation consisting of cup vane and temperature probes, primarily used for mean profile measurements of velocity and temperature respectively. The second system, a hot film and thermocouple system, was used for measurement of turbulence variances and covariances and spectra. The cup vane system was used to acquire data from all wind directions, while the hot film system was primarily used for turbulence measurements from the two prevailing wind directions, south and northwest. The micrometeorological tower is a self standing nonguyed tower with five working platforms at 15.2m (50 ft.) intervals, with cup vane and aspirated temperature probes mounted at each platform.
NASA Technical Reports Server (NTRS)
Williams, R. J.
1972-01-01
The details of the construction and operation of a gas mixing furnace are presented. A solid ceramic oxygen electrolyte cell is used to monitor the oxygen fugacity in the furnace. The system consists of a standard vertical-quench, gas mixing furnace with heads designed for mounting the electrolyte cell and with facilities for inserting and removing the samples. The system also contains the highinput impedance electronics necessary for measurements and a simplified version of standard gas mixing apparatus. The calibration and maintenance of the system are discussed.
NASA Astrophysics Data System (ADS)
Li, Peng; Chong, Wenyan; Ma, Yongjun
2017-10-01
In order to avoid shortcomings of low efficiency and restricted measuring range exsited in traditional 3D on-line contact measurement method for workpiece size, the development of a novel 3D contact measurement system is introduced, which is designed for intelligent manufacturing based on stereo vision. The developed contact measurement system is characterized with an intergarted use of a handy probe, a binocular stereo vision system, and advanced measurement software.The handy probe consists of six track markers, a touch probe and the associated elcetronics. In the process of contact measurement, the hand probe can be located by the use of the stereo vision system and track markers, and 3D coordinates of a space point on the workpiece can be mearsured by calculating the tip position of a touch probe. With the flexibility of the hand probe, the orientation, range, density of the 3D contact measurenent can be adptable to different needs. Applications of the developed contact measurement system to high-precision measurement and rapid surface digitization are experimentally demonstrated.
40 CFR 89.419 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Continuous HC measurement system. (i) The continuous HC sample system (as shown in Figure 2 or 3 in appendix... this is not required. (ii) No other analyzers may draw a sample from the continuous HC sample probe... continuous HC sampling system shall consist of a probe (which must raise the sample to the specified...
21 CFR 866.5700 - Whole human plasma or serum immunological test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...
21 CFR 866.5700 - Whole human plasma or serum immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...
21 CFR 866.5700 - Whole human plasma or serum immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...
21 CFR 866.5700 - Whole human plasma or serum immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...
21 CFR 866.5700 - Whole human plasma or serum immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...
Consistent integration of experimental and ab initio data into molecular and coarse-grained models
NASA Astrophysics Data System (ADS)
Vlcek, Lukas
As computer simulations are increasingly used to complement or replace experiments, highly accurate descriptions of physical systems at different time and length scales are required to achieve realistic predictions. The questions of how to objectively measure model quality in relation to reference experimental or ab initio data, and how to transition seamlessly between different levels of resolution are therefore of prime interest. To address these issues, we use the concept of statistical distance to define a measure of similarity between statistical mechanical systems, i.e., a model and its target, and show that its minimization leads to general convergence of the systems' measurable properties. Through systematic coarse-graining, we arrive at appropriate expressions for optimization loss functions consistently incorporating microscopic ab initio data as well as macroscopic experimental data. The design of coarse-grained and multiscale models is then based on factoring the model system partition function into terms describing the system at different resolution levels. The optimization algorithm takes advantage of thermodynamic perturbation expressions for fast exploration of the model parameter space, enabling us to scan millions of parameter combinations per hour on a single CPU. The robustness and generality of the new model optimization framework and its efficient implementation are illustrated on selected examples including aqueous solutions, magnetic systems, and metal alloys.
NASA Technical Reports Server (NTRS)
Jackson, T. J.; Shiue, J.; Oneill, P.; Wang, J.; Fuchs, J.; Owe, M.
1984-01-01
The verification of a multi-sensor aircraft system developed to study soil moisture applications is discussed. This system consisted of a three beam push broom L band microwave radiometer, a thermal infrared scanner, a multispectral scanner, video and photographic cameras and an onboard navigational instrument. Ten flights were made of agricultural sites in Maryland and Delaware with little or no vegetation cover. Comparisons of aircraft and ground measurements showed that the system was reliable and consistent. Time series analysis of microwave and evaporation data showed a strong similarity that indicates a potential direction for future research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poon, Justin; Sabondjian, Eric; Sankreacha, Raxa
Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasoundmore » scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.« less
NASA Astrophysics Data System (ADS)
Iga, Mitsuhiro; Kakuryu, Nobuyuki; Tanaami, Takeo; Sajiki, Jiro; Isozaki, Katsumi; Itoh, Tamitake
2012-10-01
We describe the development of a hyper-spectral imaging (HSI) system composed of thin-film tunable band-pass filters (TF-TBPFs) and its application to inhomogeneous sample surfaces. Compared with existing HSI systems, the system has a simpler optical arrangement and has an optical transmittance of up to 80% owing to polarization independence. The HSI system exhibits a constant spectral resolution over a spectral window of 80 nm (530 to 610 nm) and tunable spectral resolution from 1.5 to 3.0 nm, and requires only 5.4 s per measurement. Plasmon resonance and surface enhanced Raman scattering (SERS) from inhomogeneous surfaces dispersed with Ag nanoparticles (NP) have been measured with the HSI system. The measurement of multiple Ag NPs is consistent with conventional isolated NP measurements as explained by the electromagnetic mechanism of SERS, demonstrating the validity of the HSI system.
Direct measurement of weakly nonequilibrium system entropy is consistent with Gibbs–Shannon form
2017-01-01
Stochastic thermodynamics extends classical thermodynamics to small systems in contact with one or more heat baths. It can account for the effects of thermal fluctuations and describe systems far from thermodynamic equilibrium. A basic assumption is that the expression for Shannon entropy is the appropriate description for the entropy of a nonequilibrium system in such a setting. Here we measure experimentally this function in a system that is in local but not global equilibrium. Our system is a micron-scale colloidal particle in water, in a virtual double-well potential created by a feedback trap. We measure the work to erase a fraction of a bit of information and show that it is bounded by the Shannon entropy for a two-state system. Further, by measuring directly the reversibility of slow protocols, we can distinguish unambiguously between protocols that can and cannot reach the expected thermodynamic bounds. PMID:29073017
NASA Technical Reports Server (NTRS)
SanSoucie, Michael P.; Vermilion, David J.; Rogers, Jan R.
2015-01-01
The NASA Marshall Space Flight Center (MSFC) electrostatic levitation (ESL) laboratory has a long history of providing materials research and thermophysical property data. A summary of the labs capabilities, recent upgrades, and ongoing and future work will be provided. The laboratory has recently added two new capabilities to its main levitation chamber: a rapid quench system and an oxygen control system. The rapid quench system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy. Thereby allowing rapid quenching of undercooled liquid metals. The oxygen control system consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity between two gas compartments separated by an electrolyte, which is yttria-stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10-36 to 100 bar. The ESL laboratory also has an emissometer, called the High-Temperature Emissivity Measurement System (HiTEMS). This system measures the spectral emissivity of materials from 600degC to 3,000degC. The system consists of a vacuum chamber, a black body source, and a Fourier Transform Infrared Spectrometer (FTIR). The system utilizes optics to swap the signal between the sample and the black body. The system was originally designed to measure the hemispherical spectral emissivity of levitated samples, which are typically 2.5mm spheres. Levitation allows emissivity measurements of molten samples, but more work is required to develop this capability. The system is currently setup measure the near-normal spectral emissivity of stationary samples, which has been used to take measurements of ablative materials, rocket nozzle coating materials, and materials for spacecraft instruments.
Bias of damped Lyman-α systems from their cross-correlation with CMB lensing
Alonso, D.; Colosimo, J.; Font-Ribera, A.; ...
2018-04-20
We cross-correlate the positions of damped Lyman-α systems (DLAs) and their parent quasar catalog with a convergence map derived from the Planck cosmic microwave background (CMB) temperature data. We then make consistent measurements of the lensing signal of both samples in both Fourier and configuration space. By interpreting the excess signal present in the DLA catalog with respect to the parent quasar catalog as caused by the large scale structure traced by DLAs, we are able to infer the bias of these objects: b DLA=2.6±0.9. These results are consistent with previous measurements made in cross-correlation with the Lyman-α forest, althoughmore » the current noise in the lensing data and the low number density of DLAs limits the constraining power of this measurement. We discuss the robustness of the analysis with respect to a number different systematic effects and forecast prospects of carrying out this measurement with data from future experiments.« less
Bias of damped Lyman-α systems from their cross-correlation with CMB lensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alonso, D.; Colosimo, J.; Font-Ribera, A.
We cross-correlate the positions of damped Lyman-α systems (DLAs) and their parent quasar catalog with a convergence map derived from the Planck cosmic microwave background (CMB) temperature data. We then make consistent measurements of the lensing signal of both samples in both Fourier and configuration space. By interpreting the excess signal present in the DLA catalog with respect to the parent quasar catalog as caused by the large scale structure traced by DLAs, we are able to infer the bias of these objects: b DLA=2.6±0.9. These results are consistent with previous measurements made in cross-correlation with the Lyman-α forest, althoughmore » the current noise in the lensing data and the low number density of DLAs limits the constraining power of this measurement. We discuss the robustness of the analysis with respect to a number different systematic effects and forecast prospects of carrying out this measurement with data from future experiments.« less
Bias of damped Lyman-α systems from their cross-correlation with CMB lensing
NASA Astrophysics Data System (ADS)
Alonso, D.; Colosimo, J.; Font-Ribera, A.; Slosar, A.
2018-04-01
We cross-correlate the positions of damped Lyman-α systems (DLAs) and their parent quasar catalog with a convergence map derived from the Planck cosmic microwave background (CMB) temperature data. We make consistent measurements of the lensing signal of both samples in both Fourier and configuration space. By interpreting the excess signal present in the DLA catalog with respect to the parent quasar catalog as caused by the large scale structure traced by DLAs, we are able to infer the bias of these objects: bDLA=2.6±0.9. These results are consistent with previous measurements made in cross-correlation with the Lyman-α forest, although the current noise in the lensing data and the low number density of DLAs limits the constraining power of this measurement. We discuss the robustness of the analysis with respect to a number different systematic effects and forecast prospects of carrying out this measurement with data from future experiments.
Chicago monostatic acoustic vortex sensing system : Vol. IV. wake vortex decay
DOT National Transportation Integrated Search
1982-07-01
A Monostatic Acoustic Vortex Sensing System (MAVSS) was installed at Chicago's O'Hare International Airport to measure the strength and decay of aircraft wake vortices from landing aircraft. The MAVSS consists of an array of acoustic antennas which m...
Chicago Monostatic Acoustic Vortex Sensing System : Volume I. Data Collection and Reduction.
DOT National Transportation Integrated Search
1979-10-01
A Monostatic Acoustic Vortex Sensing System (MAVSS) was installed at Chicago's O'Hare International Airport to measure the strength and decay of aircraft wake vortices from landing aircraft. The MAVSS consists of an array of acoustic antennas which m...
Kirchner, M K; Schulze Westerath, H; Knierim, U; Tessitore, E; Cozzi, G; Winckler, C
2014-03-01
Consistency over time of (on-farm) animal welfare assessment systems forms part of reliability, meaning that results of the assessment should be representative of the longer-term welfare state of the farm as long as the housing and management conditions have not changed considerably. This is especially important if assessments are to be used for certification purposes. It was the aim of the present study to investigate consistency over time of the Welfare Quality(®) (WQ(®)) assessment system for fattening cattle at single measure level, aggregated criterion and principle scores, and overall classification across short-term (1 month) and longer-term periods (6 months). We hypothesized that consistency over time of aggregated criterion and principle scores is higher than that of single measures. Consistency was also expected to be lower with longer intervals between assessments. Data were obtained using the WQ(®) protocol for fattening cattle during three visits (months 0, 1 and 7) on 63 beef farms in Austria, Germany and Italy. Only data from farms where no major changes in housing and management had taken place were considered for analysis. At the single measure level, Spearman rank correlations between visits were >0.7 and variance was lower within farms than between farms for six and two of 19 measures after 1 month and 6 months, respectively. After aggregation of single measures into criterion and principle scores, five and two of 10 criteria and three and one of four principles were found reliable after 1 and 6 months, respectively. At the WQ(®) principle level, this was the case for three and one of four principles. Seventy-nine per cent and 75% of the farms were allocated to the same overall welfare category after 1 month and 6 months. Possible reasons for a lack of consistency are seasonal effects or short-term fluctuations that occur under normal farm conditions, low prevalence of clinical measures and probably insufficient sample size, whereas poor inter-observer agreement leading to inflation of correlation can be ruled out. At the criterion and principle level, aggregation of information into scores appears to partly smoothen undirected variation at the single measure level without losing sensitivity in terms of welfare evaluation. Reliable on-farm animal welfare assessments should therefore be based on repeated assessments. Further long-term studies are recommended to better understand the factors influencing consistency over time.
Measuring Workload Demand of Informatics Systems with the Clinical Case Demand Index
Iyengar, M. Sriram; Rogith, Deevakar; Florez-Arango, Jose F
2017-01-01
Introduction: The increasing use of Health Information Technology (HIT) can add substantially to workload on clinical providers. Current methods for assessing workload do not take into account the nature of clinical cases and the use of HIT tools while solving them. Methods: The Clinical Case Demand Index (CCDI), consisting of a summary score and visual representation, was developed to meet this need. Consistency with current perceived workload measures was evaluated in a Randomized Control Trial of a mobile health system. Results: CCDI is significantly correlated with existing workload measures and inversely related to provider performance. Discussion: CCDI combines subjective and objective characteristics of clinical cases along with cognitive and clinical dimensions. Applications include evaluation of HIT tools, clinician scheduling, medical education. Conclusion: CCDI supports comparative effectiveness research of HIT tools. In addition, CCDI could have numerous applications including training, clinical trials, design of clinical workflows, and others. PMID:29854166
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey-Collard, Patrick
2015-10-27
From January 2015 to July 2015, I was doing research at Sandia National Laboratories in Albuquerque, United States. My work there consisted of performing experimental measurements using Sandia’s unique silicon quantum computing platform. The project is about coupling donor spin quantum bits, or qubits, to quantum dots in a silicon nanostructure based on conventional microchip technology. During the project, I devised a new quantum state readout mechanism that allow better, longer lived measurement signals. The measurement (or readout) mechanism is key to any qubit architecture. Next, I was able to demonstrate a quantum manipulation of the two-electron spin states ofmore » the coupled donor and quantum dot system. This constitutes a breakthrough for donor spin qubits in silicon because it could enable larger systems consisting of many qubits. This project will lead to publications in scientific journals, presentations in international conferences, and generates exciting new opportunities for manipulating nature at the nanoscale.« less
A compact x-ray system for two-phase flow measurement
NASA Astrophysics Data System (ADS)
Song, Kyle; Liu, Yang
2018-02-01
In this paper, a compact x-ray densitometry system consisting of a 50 kV, 1 mA x-ray tube and several linear detector arrays is developed for two-phase flow measurement. The system is capable of measuring void fraction and velocity distributions with a spatial resolution of 0.4 mm per pixel and a frequency of 1000 Hz. A novel measurement model has been established for the system which takes account of the energy spectrum of x-ray photons and the beam hardening effect. An improved measurement accuracy has been achieved with this model compared with the conventional log model that has been widely used in the literature. Using this system, void fraction and velocity distributions are measured for a bubbly and a slug flow in a 25.4 mm I.D. air-water two-phase flow test loop. The measured superficial gas velocities show an error within ±4% when compared with the gas flowmeter for both conditions.
Multipartite entanglement in fermionic systems via a geometric measure
NASA Astrophysics Data System (ADS)
Lari, Behzad; Durganandini, P.; Joag, Pramod S.
2010-12-01
We study multipartite entanglement in a system consisting of indistinguishable fermions. Specifically, we have proposed a geometric entanglement measure for N spin-(1)/(2) fermions distributed over 2L modes (single-particle states). The measure is defined on the 2L qubit space isomorphic to the Fock space for 2L single-particle states. This entanglement measure is defined for a given partition of 2L modes containing m⩾2 subsets. Thus this measure applies to m⩽2L partite fermionic systems where L is any finite number, giving the number of sites. The Hilbert spaces associated with these subsets may have different dimensions. Further, we have defined the local quantum operations with respect to a given partition of modes. This definition is generic and unifies different ways of dividing a fermionic system into subsystems. We have shown, using a representative case, that the geometric measure is invariant under local unitary operators corresponding to a given partition. We explicitly demonstrate the use of the measure to calculate multipartite entanglement in some correlated electron systems.
A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particulate matter wi...
A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particulate matter wi...
A new sensor system for mobile and aerial emission sampling was developed for open area sources, such as open burning. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, and black carbon, samplers for particulate matter with ...
49 CFR 571.122a - Standard No. 122; Motorcycle brake systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... application. Skid number means the frictional resistance of a pavement measured in accordance with ASTM E274... brake system consisting of two or more subsystems actuated by a single control designed so that a...), but not less than 0 Newtons (0 pounds). S5.8Service brake system design durability. Each motorcycle...
49 CFR 571.122a - Standard No. 122; Motorcycle brake systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... application. Skid number means the frictional resistance of a pavement measured in accordance with ASTM E274... brake system consisting of two or more subsystems actuated by a single control designed so that a...), but not less than 0 Newtons (0 pounds). S5.8Service brake system design durability. Each motorcycle...
Marwani, Hadi M; Lowry, Mark; Keating, Patrick; Warner, Isiah M; Cook, Robert L
2007-11-01
This study introduces a newly developed frequency segmentation and recombination method for frequency-domain fluorescence lifetime measurements to address the effects of changing fractional contributions over time and minimize the effects of photobleaching within multi-component systems. Frequency segmentation and recombination experiments were evaluated using a two component system consisting of fluorescein and rhodamine B. Comparison of experimental data collected in traditional and segmented fashion with simulated data, generated using different changing fractional contributions, demonstrated the validity of the technique. Frequency segmentation and recombination was also applied to a more complex system consisting of pyrene with Suwannee River fulvic acid reference and was shown to improve recovered lifetimes and fractional intensity contributions. It was observed that photobleaching in both systems led to errors in recovered lifetimes which can complicate the interpretation of lifetime results. Results showed clear evidence that the frequency segmentation and recombination method reduced errors resulting from a changing fractional contribution in a multi-component system, and allowed photobleaching issues to be addressed by commercially available instrumentation.
NASA Astrophysics Data System (ADS)
Hisatake, Shintaro; Yamaguchi, Koki; Uchida, Hirohisa; Tojyo, Makoto; Oikawa, Yoichi; Miyaji, Kunio; Nagatsuma, Tadao
2018-04-01
We propose a new asynchronous measurement system to visualize the amplitude and phase distribution of a frequency-modulated electromagnetic wave. The system consists of three parts: a nonpolarimetric electro-optic frequency down-conversion part, a phase-noise-canceling part, and a frequency-tracking part. The photonic local oscillator signal generated by electro-optic phase modulation is controlled to track the frequency of the radio frequency (RF) signal to significantly enhance the measurable RF bandwidth. We demonstrate amplitude and phase measurement of a quasi-millimeter-wave frequency-modulated continuous-wave signal (24 GHz ± 80 MHz with a 2.5 ms period) as a proof-of-concept experiment.
NASA Astrophysics Data System (ADS)
Kino, Saiko; Omori, Suguru; Matsuura, Yuji
2016-03-01
An attenuated-total-reflection (ATR), mid-infrared spectroscopy system that consists of hollow optical fibers, a trapezoidal multi-reflection ATR prism, and a conventional FT-IR spectrometer has been developed to measure blood glucose levels. Owing to the low transmission loss and high flexibility of the hollow-optical fiber, the system can measure any sites of the human body where blood capillaries are close to the surface of mucosa, such as inner lips. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. The results of in-vivo measurement of human inner lips showed the feasibility of the proposed system, and the measurement errors were within 20%.
Code of Federal Regulations, 2010 CFR
2010-07-01
... academic skills; (2) One or more measures of the following: (i) Student competency attainment. (ii) Job or... skills in the industry the student is preparing to enter. (iii) Retention in school or completion of... appropriate, for consistency with— (1) Standards and measures developed under job opportunities and basic...
Ground-based lidar for atmospheric boundary layer ozone measurements.
Kuang, Shi; Newchurch, Michael J; Burris, John; Liu, Xiong
2013-05-20
Ground-based lidars are suitable for long-term ozone monitoring as a complement to satellite and ozonesonde measurements. However, current ground-based lidars are unable to consistently measure ozone below 500 m above ground level (AGL) due to both engineering issues and high retrieval sensitivity to various measurement errors. In this paper, we present our instrument design, retrieval techniques, and preliminary results that focus on the high-temporal profiling of ozone within the atmospheric boundary layer (ABL) achieved by the addition of an inexpensive and compact mini-receiver to the previous system. For the first time, to the best of our knowledge, the lowest, consistently achievable observation height has been extended down to 125 m AGL for a ground-based ozone lidar system. Both the analysis and preliminary measurements demonstrate that this lidar measures ozone with a precision generally better than ±10% at a temporal resolution of 10 min and a vertical resolution from 150 m at the bottom of the ABL to 550 m at the top. A measurement example from summertime shows that inhomogeneous ozone aloft was affected by both surface emissions and the evolution of ABL structures.
High temperature electromagnetic characterization of thermal protection system tile materials
NASA Technical Reports Server (NTRS)
Heil, Garrett G.
1993-01-01
This study investigated the impact of elevated temperatures on the electromagnetic performance of the LI-2200 thermal protection system. A 15-kilowatt CO2 laser was used to heat an LI-2200 specimen to 3000 F while electromagnetic measurements were performed over the frequency range of l9 to 21 GHz. The electromagnetic measurement system consisted of two Dual-Lens Spot-Focusing (DLSF) antennas, a sample support structure, and an HP-8510B vector network analyzer. Calibration of the electromagnetic system was accomplished with a Transmission-Reflection-Line (TRL) procedure and was verified with measurements on a two-layer specimen of known properties. The results of testing indicated that the LI-2200 system's electromagnetic performance is slightly temperature dependent at temperatures up to 3000 F.
Kenmochi, N; Minami, T; Takahashi, C; Tei, S; Mizuuchi, T; Kobayashi, S; Nagasaki, K; Nakamura, Y; Okada, H; Kado, S; Yamamoto, S; Ohshima, S; Konoshima, S; Shi, N; Zang, L; Ohtani, Y; Kasajima, K; Sano, F
2014-11-01
A Nd:YAG Thomson scattering system has been developed for Heliotron J. The system consists of two 550 mJ 50 Hz lasers, large collection optics, and 25 radial channel (∼1 cm spatial resolution) interference polychromators. This measurement system achieves a S/N ratio of ∼50 for low-density plasma (ne ∼ 0.5 × 10(19) m(-3)). A time evolution of electron temperature profiles was measured with this system for a high-intensity gas-puff (HIGP) fueling neutral-beam-injection plasma. The peripheral temperature of the higher-density phase after HIGP recovers to the low-density pre-HIGP level, suggesting that improving particle transport in the HIGP plasma may be possible.
Direct measurement of the impulse in a magnetic thrust chamber system for laser fusion rocket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maeno, Akihiro; Yamamoto, Naoji; Nakashima, Hideki
2011-08-15
An experiment is conducted to measure an impulse for demonstrating a magnetic thrust chamber system for laser fusion rocket. The impulse is produced by the interaction between plasma and magnetic field. In the experiment, the system consists of plasma and neodymium permanent magnets. The plasma is created by a single-beam laser aiming at a polystyrene spherical target. The impulse is 1.5 to 2.2 {mu}Ns by means of a pendulum thrust stand, when the laser energy is 0.7 J. Without magnetic field, the measured impulse is found to be zero. These results indicate that the system for generating impulse is working.
Santarpia, Joshua L; Pan, Yong-Le; Hill, Steven C; Baker, Neal; Cottrell, Brian; McKee, Laura; Ratnesar-Shumate, Shanna; Pinnick, Ronald G
2012-12-31
A laboratory system for exposing aerosol particles to ozone and rapidly measuring the subsequent changes in their single-particle fluorescence is reported. The system consists of a rotating drum chamber and a single-particle fluorescence spectrometer (SPFS) utilizing excitation at 263 nm. Measurements made with this system show preliminary results on the ultra-violet laser-induced-fluorescence (UV-LIF) spectra of single aerosolized particles of Yersinia rohdei, and of MS2 (bacteriophage) exposed to ozone. When bioparticles are exposed in the chamber the fluorescence emission peak around 330 nm: i) decreases in intensity relative to that of the 400-550 nm band; and ii) shifts slightly toward shorter-wavelengths (consistent with further drying of the particles). In these experiments, changes were observed at exposures below the US Environmental Protection Agency (EPA) limits for ozone.
Development of the Systems Thinking Scale for Adolescent Behavior Change.
Moore, Shirley M; Komton, Vilailert; Adegbite-Adeniyi, Clara; Dolansky, Mary A; Hardin, Heather K; Borawski, Elaine A
2018-03-01
This report describes the development and psychometric testing of the Systems Thinking Scale for Adolescent Behavior Change (STS-AB). Following item development, initial assessments of understandability and stability of the STS-AB were conducted in a sample of nine adolescents enrolled in a weight management program. Exploratory factor analysis of the 16-item STS-AB and internal consistency assessments were then done with 359 adolescents enrolled in a weight management program. Test-retest reliability of the STS-AB was .71, p = .03; internal consistency reliability was .87. Factor analysis of the 16-item STS-AB indicated a one-factor solution with good factor loadings, ranging from .40 to .67. Evidence of construct validity was supported by significant correlations with established measures of variables associated with health behavior change. We provide beginning evidence of the reliability and validity of the STS-AB to measure systems thinking for health behavior change in young adolescents.
Development of the Systems Thinking Scale for Adolescent Behavior Change
Moore, Shirley M.; Komton, Vilailert; Adegbite-Adeniyi, Clara; Dolansky, Mary A.; Hardin, Heather K.; Borawski, Elaine A.
2017-01-01
This report describes the development and psychometric testing of the Systems Thinking Scale for Adolescent Behavior Change (STS-AB). Following item development, initial assessments of understandability and stability of the STS-AB were conducted in a sample of nine adolescents enrolled in a weight management program. Exploratory factor analysis of the 16-item STS-AB and internal consistency assessments were then done with 359 adolescents enrolled in a weight management program. Test–retest reliability of the STS-AB was .71, p = .03; internal consistency reliability was .87. Factor analysis of the 16-item STS-AB indicated a one-factor solution with good factor loadings, ranging from .40 to .67. Evidence of construct validity was supported by significant correlations with established measures of variables associated with health behavior change. We provide beginning evidence of the reliability and validity of the STS-AB to measure systems thinking for health behavior change in young adolescents. PMID:28303755
Dorn, Barry C; Savoia, Elena; Testa, Marcia A; Stoto, Michael A; Marcus, Leonard J
2007-01-01
Survey instruments for evaluating public health preparedness have focused on measuring the structure and capacity of local, state, and federal agencies, rather than linkages among structure, process, and outcomes. To focus evaluation on the latter, we evaluated the linkages among individuals, organizations, and systems using the construct of "connectivity" and developed a measurement instrument. Results from focus groups of emergency preparedness first responders generated 62 items used in the development sample of 187 respondents. Item reduction and factors analyses were conducted to confirm the scale's components. The 62 items were reduced to 28. Five scales explained 70% of the total variance (number of items, percent variance explained, Cronbach's alpha) including connectivity with the system (8, 45%, 0.94), coworkers (7, 7%, 0.91), organization (7, 12%, 0.93), and perceptions (6, 6%, 0.90). Discriminant validity was found to be consistent with the factor structure. We developed a Connectivity Measurement Tool for the public health workforce consisting of a 34-item questionnaire found to be a reliable measure of connectivity with preliminary evidence of construct validity.
Grieve, Stuart M; Korgaonkar, Mayuresh S; Clark, C Richard; Williams, Leanne M
2011-04-01
Magnetic resonance imaging (MRI) studies of structural brain development have suggested that the limbic system is relatively preserved in comparison to other brain regions with healthy aging. The goal of this study was to systematically investigate age-related changes of the limbic system using measures of cortical thickness, volumetric and diffusion characteristics. We also investigated if the "relative preservation" concept is consistent across the individual sub-regions of the limbic system. T1 weighted structural MRI and Diffusion Tensor Imaging data from 476 healthy participants from the Brain Resource International Database was used for this study. Age-related changes in grey matter (GM)/white matter (WM) volume, cortical thickness, diffusional characteristics for the pericortical WM and for the fiber tracts associated with the limbic regions were quantified. A regional variability in the aging patterns across the limbic system was present. Four important patterns of age-related changes were highlighted for the limbic sub-regions: 1. early maturation of GM with late loss in the hippocampus and amygdala; 2. an extreme pattern of GM preservation in the entorhinal cortex; 3. a flat pattern of reduced GM loss in the anterior cingulate and the parahippocampus and; 4. accelerated GM loss in the isthmus and posterior cingulate. The GM volumetric data and cortical thickness measures proved to be internally consistent, while the diffusional measures provided complementary data that seem consistent with the GM trends identified. This heterogeneity can be hypothesized to be associated with age-related changes of cognitive function specialized for that region and direct connections to the other brain regions sub-serving these functions. Copyright © 2011 Elsevier Inc. All rights reserved.
Dual side control for inductive power transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Hunter; Sealy, Kylee; Gilchrist, Aaron
An apparatus for dual side control includes a measurement module that measures a voltage and a current of an IPT system. The voltage includes an output voltage and/or an input voltage and the current includes an output current and/or an input current. The output voltage and the output current are measured at an output of the IPT system and the input voltage and the input current measured at an input of the IPT system. The apparatus includes a max efficiency module that determines a maximum efficiency for the IPT system. The max efficiency module uses parameters of the IPT systemmore » to iterate to a maximum efficiency. The apparatus includes an adjustment module that adjusts one or more parameters in the IPT system consistent with the maximum efficiency calculated by the max efficiency module.« less
NASA Technical Reports Server (NTRS)
Cooke, W. J.; Brown, P. G.; Stober, G.; Schult, C.; Krzeminski, Z.; Chau, J. L.
2017-01-01
We describe a two year campaign of simultaneous automated meteor optical and head echo radar measurements conducted with the Middle Atmosphere Alomar Radar System (MAARSY). This campaign was established with the following goals: Compare trajectories as measured by MAARSY and the two optical stations for a range of meteoroid masses. Compare photometric and dynamic mass measured optically with radar-derived masses (inter-calibration of mass scales). Use the best observed simultaneous events to fuse all metric, photometric and ionization estimates together and apply different ablation models to self-consistently model these highest quality events.
A new passive radon-thoron discriminative measurement system.
Sciocchetti, G; Sciocchetti, A; Giovannoli, P; DeFelice, P; Cardellini, F; Cotellessa, G; Pagliari, M
2010-10-01
A new passive radon-thoron discriminative measurement system has been developed for monitoring radon and thoron individually. It consists of a 'couple' of passive integrating devices with a CR39 nuclear track detector (NTD). The experimental prototype is based on the application of a new concept of NTD instrument developed at ENEA, named Alpha-PREM, acronym of piston radon exposure meter, which allows controlling the detector exposure with a patented sampling technique (Int. Eu. Pat. and US Pat.). The 'twin diffusion chambers system' was based on two A-PREM devices consisting of the standard device, named NTD-Rn, and a modified version, named NTD-Rn/Tn, which was set up to improve thoron sampling efficiency of the diffusion chamber, without changing the geometry and the start/stop function of the NTD-Rn device. Coupling devices fitted on each device allowed getting a system, which works as a double-chamber structure when deployed at the monitoring position. In this paper both technical and physical aspects are considered.
Emulsion stability measurements by single electrode capacitance probe (SeCaP) technology
NASA Astrophysics Data System (ADS)
Schüller, R. B.; Løkra, S.; Salas-Bringas, C.; Egelandsdal, B.; Engebretsen, B.
2008-08-01
This paper describes a new and novel method for the determination of the stability of emulsions. The method is based on the single electrode capacitance technology (SeCaP). A measuring system consisting of eight individual measuring cells, each with a volume of approximately 10 ml, is described in detail. The system has been tested on an emulsion system based on whey proteins (WPC80), oil and water. Xanthan was added to modify the emulsion stability. The results show that the new measuring system is able to quantify the stability of the emulsion in terms of a differential variable. The whole separation process is observed much faster in the SeCaP system than in a conventional separation column. The complete separation process observed visually over 30 h is seen in less than 1.4 h in the SeCaP system.
NASA Astrophysics Data System (ADS)
Loftus, Pete; Giudice, Seb
2014-08-01
Measurements underpin the engineering decisions that allow products to be designed, manufactured, operated, and maintained. Therefore, the quality of measured data needs to be systematically assured to allow decision makers to proceed with confidence. The use of standards is one way of achieving this. This paper explores the relevance of international documentary standards to the assessment of measurement system capability in High Value Manufacturing (HVM) Industry. An internal measurement standard is presented which supplements these standards and recommendations are made for a cohesive effort to develop the international standards to provide consistency in such industrial applications.
Measurement of whole tire profile
NASA Astrophysics Data System (ADS)
Yang, Yongyue; Jiao, Wenguang
2010-08-01
In this paper, a precision measuring device is developed for obtaining characteristic curve of tire profile and its geometric parameters. It consists of a laser displacement measurement unit, a closed-loop precision two-dimensional coordinate table, a step motor control system and a fast data acquisition and analysis system. Based on the laser trigonometry, a data map of tire profile and coordinate values of all points can be obtained through corresponding data transformation. This device has a compact structure, a convenient control, a simple hardware circuit design and a high measurement precision. Experimental results indicate that measurement precision can meet the customer accuracy requirement of +/-0.02 mm.
Automated acquisition system for routine, noninvasive monitoring of physiological data.
Ogawa, M; Tamura, T; Togawa, T
1998-01-01
A fully automated, noninvasive data-acquisition system was developed to permit long-term measurement of physiological functions at home, without disturbing subjects' normal routines. The system consists of unconstrained monitors built into furnishings and structures in a home environment. An electrocardiographic (ECG) monitor in the bathtub measures heart function during bathing, a temperature monitor in the bed measures body temperature, and a weight monitor built into the toilet serves as a scale to record weight. All three monitors are connected to one computer and function with data-acquisition programs and a data format rule. The unconstrained physiological parameter monitors and fully automated measurement procedures collect data noninvasively without the subject's awareness. The system was tested for 1 week by a healthy male subject, aged 28, in laboratory-based facilities.
McKenzie, Erica R; Young, Thomas M
2013-01-01
Size exclusion chromatography (SEC), which separates molecules based on molecular volume, can be coupled with online inductively coupled plasma mass spectrometry (ICP-MS) to explore size-dependent metal-natural organic matter (NOM) complexation. To make effective use of this analytical dual detector system, the operator should be mindful of quality control measures. Al, Cr, Fe, Se, and Sn all exhibited columnless attenuation, which indicated unintended interactions with system components. Based on signal-to-noise ratio and peak reproducibility between duplicate analyses of environmental samples, consistent peak time and height were observed for Mg, Cl, Mn, Cu, Br, and Pb. Al, V, Fe, Co, Ni, Zn, Se, Cd, Sn, and Sb were less consistent overall, but produced consistent measurements in select samples. Ultrafiltering and centrifuging produced similar peak distributions, but glass fiber filtration produced more high molecular weight (MW) peaks. Storage in glass also produced more high MW peaks than did plastic bottles.
The Danish Barriers Questionnaire-II: preliminary validation in cancer pain patients.
Jacobsen, Ramune; Møldrup, Claus; Christrup, Lona; Sjøgren, Per; Hansen, Ole Bo
2009-01-01
The objective of this study was to examine the psychometric properties of the Danish version of the Barriers Questionnaire-II (DBQ-II). The validated Norwegian version of the DBQ-II was translated into Danish. Cancer patients for the study were recruited from specialized pain management facilities. Thirty-three patients responded to the DBQ-II, Hospital Anxiety and Depression Scale, and Brief Pain Inventory pain severity scale. A factor analysis of the DBQ-II resulted in six scales. Scale one, Fatalism, consisted of three items addressing fatalistic beliefs regarding cancer pain management. Scale two, Immune System, consisted of three items addressing the belief that pain medications harm the immune system. Scale three, Monitor, consisted of three items addressing the fear that pain medicine masks changes in one's body. Scale four, Communication, consisted of five items addressing the concern that reports of pain distract the physician from treating the cancer, and the belief that "good" patients do not complain. Scale five, Addiction, consisted of two items addressing the fear of becoming addicted to pain medication. Finally, scale six, Tolerance, consisted of three items addressing the fear of getting tolerant to analgesic effect of pain medicine. Items related to medication side effects were analyzed as separate units. The DBQ-II total had an internal consistency of 0.87. The DBQ-II total score was related to measures of pain relief and anxiety. The DBQ-II seems to be a reliable and valid measure of the barriers to pain management among Danish cancer patients.
A battery-run pulsed motor with inherent dynamic electronic switch control
NASA Astrophysics Data System (ADS)
Tripathi, K. C.; Lal, P.; Sarma, P. R.; Sharma, A. K.; Prakash, V.
1980-02-01
A new type of battery-run brushless ferrite-magnet dc motor system is described. Its rotor part consists of a few permanent ceramic (ferrite) magnets uniformly spread on the rim of a disk (wheel) and the stator part consists of electromagnets placed in such a way that when energized, they always form a repulsive couple to rotate the disk. A sensor coil is placed to give an induced pulse signal, which acts as an inherent dynamic switching time control for the automatic electronic control system. Control of speed, brake system, and safety measures are also discussed. Experimental values for the present system are given. Some possible applications are suggested.
Low-Power Testing of Losses in Millimeter-Wave Transmission Lines for High-Power Applications
Han, S. T.; Comfoltey, E. N.; Shapiro, M. A.; Sirigiri, J. R.; Tax, D. S.; Temkin, R. J.; Woskov, P. P.; Rasmussen, D. A.
2008-01-01
We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3±0.1 dB per miter bend using a VNA; and 0.22±0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05±0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications. PMID:19081774
A new method for distortion magnetic field compensation of a geomagnetic vector measurement system
NASA Astrophysics Data System (ADS)
Liu, Zhongyan; Pan, Mengchun; Tang, Ying; Zhang, Qi; Geng, Yunling; Wan, Chengbiao; Chen, Dixiang; Tian, Wugang
2016-12-01
The geomagnetic vector measurement system mainly consists of three-axis magnetometer and an INS (inertial navigation system), which have many ferromagnetic parts on them. The magnetometer is always distorted by ferromagnetic parts and other electric equipments such as INS and power circuit module within the system, which can lead to geomagnetic vector measurement error of thousands of nT. Thus, the geomagnetic vector measurement system has to be compensated in order to guarantee the measurement accuracy. In this paper, a new distortion magnetic field compensation method is proposed, in which a permanent magnet with different relative positions is used to change the ambient magnetic field to construct equations of the error model parameters, and the parameters can be accurately estimated by solving linear equations. In order to verify effectiveness of the proposed method, the experiment is conducted, and the results demonstrate that, after compensation, the components errors of measured geomagnetic field are reduced significantly. It demonstrates that the proposed method can effectively improve the accuracy of the geomagnetic vector measurement system.
Entanglement measures in embedding quantum simulators with nuclear spins
NASA Astrophysics Data System (ADS)
Xin, Tao; Pedernales, Julen S.; Solano, Enrique; Long, Gui-Lu
2018-02-01
We implement an embedding quantum simulator (EQS) in nuclear spin systems. The experiment consists of a simulator of up to three qubits, plus a single ancillary qubit, where we are able to efficiently measure the concurrence and the three-tangle of two-qubit and three-qubit systems as they undergo entangling dynamics. The EQS framework allows us to drastically reduce the number of measurements needed for this task, which otherwise would require full-state reconstruction of the qubit system. Our simulator is built of the nuclear spins of four 13C atoms in a molecule of trans-crotonic acid manipulated with NMR techniques.
CCD Astrometry with Robotic Telescopes
NASA Astrophysics Data System (ADS)
AlZaben, Faisal; Li, Dewei; Li, Yongyao; Dennis, Aren Fene, Michael; Boyce, Grady; Boyce, Pat
2016-01-01
CCD images were acquired of three binary star systems: WDS06145+1148, WDS06206+1803, and WDS06224+2640. The astrometric solution, position angle, and separation of each system were calculated with MaximDL v6 and Mira Pro x64 software suites. The results were consistent with historical measurements in the Washington Double Star Catalog. Our analysis found some differences in measurements between single-shot color CCD cameras and traditional monochrome CCDs using a filter wheel.
Lin, Jia-Hua; McGorry, Raymond W; Chang, Chien-Chi
2007-05-01
A hand-handle interface force and torque measurement system is introduced to fill the void acknowledged in the international standard ISO 6544, which governs pneumatic, assembly tool reaction torque and force measurement. This system consists of an instrumented handle with a sensor capable of measuring grip force and reaction hand moment when threaded, fastener-driving tools are used by operators. The handle is rigidly affixed to the tool in parallel to the original tool handle allowing normal fastener-driving operations with minimal interference. Demonstration of this proposed system was made with tools of three different shapes: pistol grip, right angle, and in-line. During tool torque buildup, the proposed system measured operators exerting greater grip force on the soft joint than on the hard joint. The system also demonstrated that the soft joint demanded greater hand moment impulse than the hard joint. The results demonstrate that the measurement system can provide supplemental data useful in exposure assessment with power hand tools as proposed in ISO 6544.
Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns
NASA Astrophysics Data System (ADS)
Trifkovic, B.; Budak, I.; Todorovic, A.; Hodolic, J.; Puskar, T.; Jevremovic, D.; Vukelic, D.
2012-01-01
The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.
Tightly Coupled Inertial Navigation System/Global Positioning System (TCMIG)
NASA Technical Reports Server (NTRS)
Watson, Michael D.; Jackson, Kurt (Technical Monitor)
2002-01-01
Many NASA applications planned for execution later this decade are seeking high performance, miniaturized, low power Inertial Management Units (IMU). Much research has gone into Micro-Electro-Mechanical System (MEMS) over the past decade as a solution to these needs. While MEMS devices have proven to provide high accuracy acceleration measurements, they have not yet proven to have the accuracy required by many NASA missions in rotational measurements. Therefore, a new solution has been formulated integrating the best of all IMU technologies to address these mid-term needs in the form of a Tightly Coupled Micro Inertial Navigation System (INS)/Global Positioning System (GPS) (TCMIG). The TCMIG consists of an INS and a GPS tightly coupled by a Kalman filter executing on an embedded Field Programmable Gate Array (FPGA) processor. The INS consists of a highly integrated Interferometric Fiber Optic Gyroscope (IFOG) and a MEMS accelerometer. The IFOG utilizes a tightly wound fiber coil to reduce volume and the high level of integration and advanced optical components to reduce power. The MEMS accelerometer utilizes a newly developed deep etch process to increase the proof mass and yield a highly accurate accelerometer. The GPS receiver consists of a low power miniaturized version of the Blackjack receiver. Such an IMU configuration is ideal to meet the mid-term needs of the NASA Science Enterprises and the new launch vehicles being developed for the Space Launch Initiative (SLI).
Schön, Ulla-Karin; Svedberg, Petra; Rosenberg, David
2015-05-01
Recovery is understood to be an individual process that cannot be controlled, but can be supported and facilitated at the individual, organizational and system levels. Standardized measures of recovery may play a critical role in contributing to the development of a recovery-oriented system. The INSPIRE measure is a 28-item service user-rated measure of recovery support. INSPIRE assesses both the individual preferences of the user in the recovery process and their experience of support from staff. The aim of this study was to evaluate the psychometric properties of the Swedish version of the INSPIRE measure, for potential use in Swedish mental health services and in order to promote recovery in mental illness. The sample consisted of 85 participants from six community mental health services targeting people with a diagnosis of psychosis in a municipality in Sweden. For the test-retest evaluation, 78 participants completed the questionnaire 2 weeks later. The results in the present study indicate that the Swedish version of the INSPIRE measure had good face and content validity, satisfactory internal consistency and some level of instability in test-retest reliability. While further studies that test the instrument in a larger and more diverse clinical context are needed, INSPIRE can be considered a relevant and feasible instrument to utilize in supporting the development of a recovery-oriented system in Sweden.
Emissions of aromatic air toxics from aircraft ground equipment were measured with a resonance enhanced multiphoton ionization—time of flight mass spectrometry (REMPI-TOFMS) system consisting of a pulsed solid state laser for photoionization and a TOFMS for mass discrimination. T...
Microwave sensing of moisture content and bulk density in flowing grain
USDA-ARS?s Scientific Manuscript database
Moisture content and bulk density were determined from measurement of the dielectric properties of flowing wheat kernels at a single microwave frequency (5.8 GHz). The measuring system consisted of two high-gain microwave patch antennas mounted on opposite sides of rectangular chute and connected to...
Surface Energy Balance System (SEBS) Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, DR
2011-02-14
A Surface Energy Balance System (SEBS) has been installed collocated with each deployed ECOR system at the Southern Great Plains (SGP), North Slope of Alaska (NSA), Tropical Western Pacific (TWP), ARM Mobile Facility 1 (AMF1), and ARM Mobile Facility 2 (AMF2). The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.
The Tucson Electric Power Solar Test Yard
NASA Astrophysics Data System (ADS)
Lonij, Vincent; Orsburn, Sean; Salhab, Anas; Kopp, Emily; Brooks, Adria; Jayadevan, Vijai; Greenberg, James; St. Germaine, Michael; Allen, Nate; Jones, Sarah; Hardesty, Garrett; Cronin, Alex
2011-10-01
In collaboration with Tucson Electric Power we studied the performance of twenty different grid-tied photovoltaic systems, consisting of over 600 PV modules in all. We added data acquisition hardware to monitor DC power from the modules, AC power from the inverters, PV module temperatures, and meteorological data such as the irradiance incident on the PV systems. We report measurements of PV system yields and efficiencies over periods of minutes, days, and years. We also report temperature and irradiance coefficients of efficiency and measurements of long-term degradation. We also use our data to validate models that predict the output from PV systems.
Recent advances in laser triangulation-based measurement of airfoil surfaces
NASA Astrophysics Data System (ADS)
Hageniers, Omer L.
1995-01-01
The measurement of aircraft jet engine turbine and compressor blades requires a high degree of accuracy. This paper will address the development and performance attributes of a noncontact electro-optical gaging system specifically designed to meet the airfoil dimensional measurement requirements inherent in turbine and compressor blade manufacture and repair. The system described consists of the following key components: a high accuracy, dual channel, laser based optical sensor, a four degree of freedom mechanical manipulator system and a computer based operator interface. Measurement modes of the system include point by point data gathering at rates up to 3 points per second and an 'on-the-fly' mode where points can be gathered at data rates up to 20 points per second at surface scanning speeds of up to 1 inch per second. Overall system accuracy is +/- 0.0005 inches in a configuration that is useable in the blade manufacturing area. The systems ability to input design data from CAD data bases and output measurement data in a CAD compatible data format is discussed.
Chicago Monostatic Acoustic Vortex Sensing System : Vol. II. Decay of B-707 and DC-8 Vortices.
DOT National Transportation Integrated Search
1981-09-01
A Monostatic Acoustic Vortex Sensing System (MAVSS) was installed at Chicago's O'Hare International Airport to measure the strength and decay of aircraft wake vortices from landing aircraft. The MAVSS consists of an array of acoustic antennas which m...
21 CFR 866.5180 - Fecal calprotectin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunological test system is an in vitro diagnostic device that consists of reagents used to quantitatively measure, by immunochemical techniques, fecal calprotectin in human stool specimens. The device is intended forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically...
21 CFR 866.5360 - Cohn fraction IV immuno-logical test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
...-lipoprotein), malnutrition, iron deficiency anemia, red blood cell disorders, and kidney disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in... test system is a device that consists of or measures that fraction of plasma proteins, predominantly...
21 CFR 866.5360 - Cohn fraction IV immuno-logical test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
...-lipoprotein), malnutrition, iron deficiency anemia, red blood cell disorders, and kidney disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in... test system is a device that consists of or measures that fraction of plasma proteins, predominantly...
21 CFR 866.5360 - Cohn fraction IV immuno-logical test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
...-lipoprotein), malnutrition, iron deficiency anemia, red blood cell disorders, and kidney disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in... test system is a device that consists of or measures that fraction of plasma proteins, predominantly...
21 CFR 866.5360 - Cohn fraction IV immuno-logical test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
...-lipoprotein), malnutrition, iron deficiency anemia, red blood cell disorders, and kidney disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in... test system is a device that consists of or measures that fraction of plasma proteins, predominantly...
Citizen Science Air Monitor (CSAM) Operating Procedures
The Citizen Science Air Monitor (CSAM) is an air monitoring system designed for measuring nitrogen dioxide (NO2) and particulate matter (PM) pollutants simultaneously. This self-contained system consists of a CairPol CairClip NO2 sensor, a Thermo Scientific personal DataRAM PM2.5...
Synthetic wind speed scenarios generation for probabilistic analysis of hybrid energy systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Jun; Rabiti, Cristian
Hybrid energy systems consisting of multiple energy inputs and multiple energy outputs have been proposed to be an effective element to enable ever increasing penetration of clean energy. In order to better understand the dynamic and probabilistic behavior of hybrid energy systems, this paper proposes a model combining Fourier series and autoregressive moving average (ARMA) to characterize historical weather measurements and to generate synthetic weather (e.g., wind speed) data. In particular, Fourier series is used to characterize the seasonal trend in historical data, while ARMA is applied to capture the autocorrelation in residue time series (e.g., measurements minus seasonal trends).more » The generated synthetic wind speed data is then utilized to perform probabilistic analysis of a particular hybrid energy system con guration, which consists of nuclear power plant, wind farm, battery storage, natural gas boiler, and chemical plant. As a result, requirements on component ramping rate, economic and environmental impacts of hybrid energy systems, and the effects of deploying different sizes of batteries in smoothing renewable variability, are all investigated.« less
Synthetic wind speed scenarios generation for probabilistic analysis of hybrid energy systems
Chen, Jun; Rabiti, Cristian
2016-11-25
Hybrid energy systems consisting of multiple energy inputs and multiple energy outputs have been proposed to be an effective element to enable ever increasing penetration of clean energy. In order to better understand the dynamic and probabilistic behavior of hybrid energy systems, this paper proposes a model combining Fourier series and autoregressive moving average (ARMA) to characterize historical weather measurements and to generate synthetic weather (e.g., wind speed) data. In particular, Fourier series is used to characterize the seasonal trend in historical data, while ARMA is applied to capture the autocorrelation in residue time series (e.g., measurements minus seasonal trends).more » The generated synthetic wind speed data is then utilized to perform probabilistic analysis of a particular hybrid energy system con guration, which consists of nuclear power plant, wind farm, battery storage, natural gas boiler, and chemical plant. As a result, requirements on component ramping rate, economic and environmental impacts of hybrid energy systems, and the effects of deploying different sizes of batteries in smoothing renewable variability, are all investigated.« less
21 CFR 866.5340 - Ferritin immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... affecting iron metabolism, such as hemochromatosis (iron overload) and iron deficiency amemia. (b... that consists of the reagents used to measure by immunochemical techniques the ferritin (an iron...
21 CFR 866.5340 - Ferritin immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... affecting iron metabolism, such as hemochromatosis (iron overload) and iron deficiency amemia. (b... that consists of the reagents used to measure by immunochemical techniques the ferritin (an iron...
21 CFR 866.5340 - Ferritin immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... affecting iron metabolism, such as hemochromatosis (iron overload) and iron deficiency amemia. (b... that consists of the reagents used to measure by immunochemical techniques the ferritin (an iron...
21 CFR 866.5340 - Ferritin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... affecting iron metabolism, such as hemochromatosis (iron overload) and iron deficiency amemia. (b... that consists of the reagents used to measure by immunochemical techniques the ferritin (an iron...
Basic methods for measuring the reflectance color of iron oxides
NASA Astrophysics Data System (ADS)
Pospisil, Jaroslav; Hrdy, Jan; Hrdy Jan, Jr.
2007-06-01
The main contribution of the present article consists in coherent description and interpretation of the principles of basic measuring methods and colorimeters for color classification and evaluation of light reflecting samples containing iron oxides. The chosen relevant theoretical background is based on the CIE tristimulus colorimetric system (X,Y,Z), the CIE colorimetric system (L*,a*,b*) and the Munsell colorimetric system (H,V,C). As an example of color identification and evaluation, some specific mathematical and graphical relationships between the soil redness rate and the corresponding hematite content are shown.
MATSurv: multisensor air traffic surveillance system
NASA Astrophysics Data System (ADS)
Yeddanapudi, Murali; Bar-Shalom, Yaakov; Pattipati, Krishna R.; Gassner, Richard R.
1995-09-01
This paper deals with the design and implementation of MATSurv 1--an experimental Multisensor Air Traffic Surveillance system. The proposed system consists of a Kalman filter based state estimator used in conjunction with a 2D sliding window assignment algorithm. Real data from two FAA radars is used to evaluate the performance of this algorithm. The results indicate that the proposed algorithm provides a superior classification of the measurements into tracks (i.e., the most likely aircraft trajectories) when compared to the aircraft trajectories obtained using the measurement IDs (squawk or IFF code).
Chakrabarti, C G; Ghosh, Koyel
2013-10-01
In the present paper we have first introduced a measure of dynamical entropy of an ecosystem on the basis of the dynamical model of the system. The dynamical entropy which depends on the eigenvalues of the community matrix of the system leads to a consistent measure of complexity of the ecosystem to characterize the dynamical behaviours such as the stability, instability and periodicity around the stationary states of the system. We have illustrated the theory with some model ecosystems. Copyright © 2013 Elsevier Inc. All rights reserved.
Pre- and postselected quantum systems, counterfactual measurements, and consistent histories
NASA Astrophysics Data System (ADS)
Cohen, O.
1995-06-01
We examine some surprising results that have been obtained for pre- and postselected quantum systems. We show that these results depend on a counterfactual interpretation of the rule of Aharonov, Bergmann, and Lebowitz [Phys. Rev. 134, B1410 (1964)] (the ABL rule) and that this interpretation is not valid in general. We then argue, with the help of the consistent histories interpretation of quantum mechanics, that there is a special class of situations where application of the counterfactual interpretation of the ABL rule can be justified. We then reexamine the aforementioned surprising results.
and feed forward stabilization) have been implemented. An on-mount gyro system consists of gyroscopes mounted on the radar antenna which sense...antenna motion and send compensating signals back to the antenna servo mechanism. Feed forward stabilization consists of determining antenna angular rates...caused by ships attitude changes, as measured by a stable platform (such as SINS), and feeding compensating signals back to the antenna servo
NASA Astrophysics Data System (ADS)
Adams, J. W.; Ondrejka, A. R.; Medley, H. W.
1987-11-01
A method of measuring the natural resonant frequencies of a structure is described. The measurement involves irradiating this structure, in this case a helicopter, with an impulsive electromagnetic (EM) field and receiving the echo reflected from the helicopter. Resonances are identified by using a mathematical algorithm based on Prony's method to operate on the digitized reflected signal. The measurement system consists of special TEM horns, pulse generators, a time-domain system, and Prony's algorithm. The frequency range covered is 5 megahertz to 250 megahertz. This range is determined by antenna and circuit characteristics. The measurement system is demonstrated, and measured data from several different helicopters are presented in different forms. These different forms are needed to determine which of the resonant frequencies are real and which are false. The false frequencies are byproducts of Prony's algorithm.
Development of portable health monitoring system for automatic self-blood glucose measurement
NASA Astrophysics Data System (ADS)
Kim, Huijun; Mizuno, Yoshihumi; Nakamachi, Eiji; Morita, Yusuke
2010-02-01
In this study, a new HMS (Health Monitoring System) device is developed for diabetic patient. This device mainly consists of I) 3D blood vessel searching unit and II) automatic blood glucose measurement (ABGM) unit. This device has features such as 1)3D blood vessel location search 2) laptop type, 3) puncturing a blood vessel by using a minimally invasive micro-needle, 4) very little blood sampling (10μl), and 5) automatic blood extraction and blood glucose measurement. In this study, ABGM unit is described in detail. It employs a syringe type's blood extraction mechanism because of its high accuracy. And it consists of the syringe component and the driving component. The syringe component consists of a syringe itself, a piston, a magnet, a ratchet and a micro-needle whose inner diameter is about 80μm. And the syringe component is disposable. The driving component consists of body parts, a linear stepping motor, a glucose enzyme sensor and a slider for accurate positioning control. The driving component has the all-in-one mechanism with a glucose enzyme sensor for compact size and stable blood transfer. On designing, required thrust force to drive the slider is designed to be greater than the value of the blood extraction force. Further, only one linear stepping motor is employed for blood extraction and transportation processes. The experimental result showed more than 80% of volume ratio under the piston speed 2.4mm/s. Further, the blood glucose was measured successfully by using the prototype unit. Finally, the availability of our ABGM unit was confirmed.
NASA Astrophysics Data System (ADS)
Chen, Xi; Zeng, Shuang; Liu, Xiulan; Jin, Yuan; Li, Xianglong; Wang, Xiaochen
2018-02-01
The electric vehicles (EV) have become accepted by increasing numbers of people for the environmental-friendly advantages. A novel way to charge the electric vehicles is through wireless power transfer (WPT). The wireless power transfer is a high power transfer system. The high currents flowing through the transmitter and receiver coils increasing temperature affects the safety of person and charging equipment. As a result, temperature measurement for wireless power transfer is needed. In this paper, a temperature measurement system based on optical fiber temperature sensors for electric vehicle wireless power transfer is proposed. Initially, the thermal characteristics of the wireless power transfer system are studied and the advantages of optical fiber sensors are analyzed. Then the temperature measurement system based on optical fiber temperature sensor is designed. The system consists of optical subsystem, data acquisition subsystem and data processing subsystem. Finally, the system is tested and the experiment result shows that the system can realize 1°C precision and can acquire real-time temperature distribution of the coils, which can meet the requirement of the temperature measuring for wireless power transfer.
Stief, Thomas; Peikenkamp, Klaus
2015-01-01
Stress occurring at the feet while wearing footwear is often determined using pressure measurement systems. However, other forms of stress, such as bending, torsional and shear loadings, cannot be detected in shoes during day-to-day activities. Nevertheless, the detection of these types of stresses would be helpful for understanding the mechanical aspects of various kinds of hard and soft tissue injuries. Therefore, we describe the development of a new measuring device that allows the reliable determination of bending and torsional load at the foot in shoes. The system consists of a measuring insole and an analogue device with Bluetooth interface. The specific shape of the insole base layer, the positions of the strain gauges, and the interconnections between them have all been selected in such a way so as to isolate bending and torsional moment detections in the medial and lateral metatarsal region. The system was calibrated using a classical two-point test procedure. A single case study was executed to evaluate the new device for practical use. This application consisted of one subject wearing neutral shoes walking on a treadmill. The calibration results (coefficients of determination R(2) > 0.999) show that bending and torsional load can be reliably detected using the measurement system presented. In the single case study, alternating bending and torsional load can be detected during walking, and the shape of the detected bending moments can be confirmed by the measurements of Arndt et al. (J Biomech 35:621-8, 2002). Despite some limitations, the presented device allows for the reliable determination of bending and torsional stresses at the foot in shoes.
Smartphone application for mechanical quality assurance of medical linear accelerators
NASA Astrophysics Data System (ADS)
Kim, Hwiyoung; Lee, Hyunseok; In Park, Jong; Choi, Chang Heon; Park, So-Yeon; Kim, Hee Jung; Kim, Young Suk; Ye, Sung-Joon
2017-06-01
Mechanical quality assurance (QA) of medical linear accelerators consists of time-consuming and human-error-prone procedures. We developed a smartphone application system for mechanical QA. The system consists of two smartphones: one attached to a gantry for obtaining real-time information on the mechanical parameters of the medical linear accelerator, and another displaying real-time information via a Bluetooth connection with the former. Motion sensors embedded in the smartphone were used to measure gantry and collimator rotations. Images taken by the smartphone’s high-resolution camera were processed to evaluate accuracies of jaw-positioning, crosshair centering and source-to-surface distance (SSD). The application was developed using Android software development kit and OpenCV library. The accuracy and precision of the system was validated against an optical rotation stage and digital calipers, prior to routine QA measurements of five medical linear accelerators. The system accuracy and precision in measuring angles and lengths were determined to be 0.05 ± 0.05° and 0.25 ± 0.14 mm, respectively. The mean absolute errors (MAEs) in QA measurements of gantry and collimator rotation were 0.05 ± 0.04° and 0.05 ± 0.04°, respectively. The MAE in QA measurements of light field was 0.39 ± 0.36 mm. The MAEs in QA measurements of crosshair centering and SSD were 0.40 ± 0.35 mm and 0.41 ± 0.32 mm, respectively. In conclusion, most routine mechanical QA procedures could be performed using the smartphone application system with improved precision and within a shorter time-frame, while eliminating potential human errors.
Smartphone application for mechanical quality assurance of medical linear accelerators.
Kim, Hwiyoung; Lee, Hyunseok; Park, Jong In; Choi, Chang Heon; Park, So-Yeon; Kim, Hee Jung; Kim, Young Suk; Ye, Sung-Joon
2017-06-07
Mechanical quality assurance (QA) of medical linear accelerators consists of time-consuming and human-error-prone procedures. We developed a smartphone application system for mechanical QA. The system consists of two smartphones: one attached to a gantry for obtaining real-time information on the mechanical parameters of the medical linear accelerator, and another displaying real-time information via a Bluetooth connection with the former. Motion sensors embedded in the smartphone were used to measure gantry and collimator rotations. Images taken by the smartphone's high-resolution camera were processed to evaluate accuracies of jaw-positioning, crosshair centering and source-to-surface distance (SSD). The application was developed using Android software development kit and OpenCV library. The accuracy and precision of the system was validated against an optical rotation stage and digital calipers, prior to routine QA measurements of five medical linear accelerators. The system accuracy and precision in measuring angles and lengths were determined to be 0.05 ± 0.05° and 0.25 ± 0.14 mm, respectively. The mean absolute errors (MAEs) in QA measurements of gantry and collimator rotation were 0.05 ± 0.04° and 0.05 ± 0.04°, respectively. The MAE in QA measurements of light field was 0.39 ± 0.36 mm. The MAEs in QA measurements of crosshair centering and SSD were 0.40 ± 0.35 mm and 0.41 ± 0.32 mm, respectively. In conclusion, most routine mechanical QA procedures could be performed using the smartphone application system with improved precision and within a shorter time-frame, while eliminating potential human errors.
NASA Astrophysics Data System (ADS)
Hwang, Darryl H.; Ma, Kevin; Yepes, Fernando; Nadamuni, Mridula; Nayyar, Megha; Liu, Brent; Duddalwar, Vinay; Lepore, Natasha
2015-12-01
A conventional radiology report primarily consists of a large amount of unstructured text, and lacks clear, concise, consistent and content-rich information. Hence, an area of unmet clinical need consists of developing better ways to communicate radiology findings and information specific to each patient. Here, we design a new workflow and reporting system that combines and integrates advances in engineering technology with those from the medical sciences, the Multidimensional Interactive Radiology Report and Analysis (MIRRA). Until recently, clinical standards have primarily relied on 2D images for the purpose of measurement, but with the advent of 3D processing, many of the manually measured metrics can be automated, leading to better reproducibility and less subjective measurement placement. Hence, we make use this newly available 3D processing in our workflow. Our pipeline is used here to standardize the labeling, tracking, and quantifying of metrics for renal masses.
Comparison between pulse wave velocities measured using Complior and measured using Biopac.
van Velzen, Marit H N; Stolker, Robert Jan; Loeve, Arjo J; Niehof, Sjoerd P; Mik, Egbert G
2018-06-06
Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed around the neck and the wrist. The Biopac system is an easier to use alternative that uses ECG and simple optical sensors to measure the PWV between the heart and the fingertips, and thus extends a bit more to the peripheral vasculature compared to the Complior system. The goal of this study was to test under various conditions to what extent these systems provide comparable and correlating values. 25 Healthy volunteers, 20-30 years old, were measured in four sequential position: sitting, lying, standing and sitting. The results showed that the Biopac system measured consistently and significantly lower PWV values than the Complior system, for all positions. Correlation values and Bland-Altman plots showed that despite the difference in PWV magnitudes obtained by the two systems the measurements did agree well. Which implies that as long as the differences in PWV magnitudes are taken into account, either system could be used to measure PWV changes over time. However, when basing diagnosis on absolute PWV values, one should be very much aware of how the PWV was measured and with what system.
An Evaluation of Relative Damage to the Powertrain System in Tracked Vehicles
Lee, Sang-Ho; Lee, Jeong-Hwan; Goo, Sang-Hwa; Cho, Yong-Cheol; Cho, Ho-Young
2009-01-01
The objective of this study was to improve the reliability of the endurance test for the powertrain system of military tracked vehicles. The measurement system that measures the driving duty applied to the powertrain system caused by mobility on roads consists of eight analog channels and two pulse channels, including the propeller shaft output torques for the left and right sides. The data obtained from this measurement system can be used to introduce a new technology that produces the output torque of a torque converter and that can be applied to analyze the revolution counting for the endurance and road mobility in the front unit and represent the relative fatigue damages analysis technique and its results according to the driven roads through a cumulative fatigue method. PMID:22573990
Application of coordinate transform on ball plate calibration
NASA Astrophysics Data System (ADS)
Wei, Hengzheng; Wang, Weinong; Ren, Guoying; Pei, Limei
2015-02-01
For the ball plate calibration method with coordinate measurement machine (CMM) equipped with laser interferometer, it is essential to adjust the ball plate parallel to the direction of laser beam. It is very time-consuming. To solve this problem, a method based on coordinate transformation between machine system and object system is presented. With the fixed points' coordinates of the ball plate measured in the object system and machine system, the transformation matrix between the coordinate systems is calculated. The laser interferometer measurement data error due to the placement of ball plate can be corrected with this transformation matrix. Experimental results indicate that this method is consistent with the handy adjustment method. It avoids the complexity of ball plate adjustment. It also can be applied to the ball beam calibration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenmochi, N., E-mail: kemmchi.naoki.62r@st.kyoto-u.ac.jp; Tei, S.; Zang, L.
2014-11-15
A Nd:YAG Thomson scattering system has been developed for Heliotron J. The system consists of two 550 mJ 50 Hz lasers, large collection optics, and 25 radial channel (∼1 cm spatial resolution) interference polychromators. This measurement system achieves a S/N ratio of ∼50 for low-density plasma (n{sub e} ∼ 0.5 × 10{sup 19} m{sup −3}). A time evolution of electron temperature profiles was measured with this system for a high-intensity gas-puff (HIGP) fueling neutral-beam-injection plasma. The peripheral temperature of the higher-density phase after HIGP recovers to the low-density pre-HIGP level, suggesting that improving particle transport in the HIGP plasma maymore » be possible.« less
THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013) FOR INTERNALLY DEPOSITED PLUTONIUM: AN OVERVIEW
DOE Office of Scientific and Technical Information (OSTI.GOV)
Birchall, A.; Vostrotin, V.; Puncher, M.
The Mayak Worker Dosimetry System (MWDS-2013) is a system for interpreting measurement data from Mayak workers from both internal and external sources. This paper is concerned with the calculation of annual organ doses for Mayak workers exposed to plutonium aerosols, where the measurement data consists mainly of activity of plutonium in urine samples. The system utilises the latest biokinetic and dosimetric models, and unlike its predecessors, takes explicit account of uncertainties in both the measurement data and model parameters. The aim of this paper is to describe the complete MWDS-2013 system (including model parameter values and their uncertainties) and themore » methodology used (including all the relevant equations) and the assumptions made. Where necessary, supplementary papers which justify specific assumptions are cited.« less
NASA Technical Reports Server (NTRS)
Wong, R. C.; Owen, H. A., Jr.; Wilson, T. G.; Rodriguez, G. E.
1980-01-01
Small-signal modeling techniques are used in a system stability analysis of a breadboard version of a complete functional electrical power system. The system consists of a regulated switching dc-to-dc converter, a solar-cell-array simulator, a solar-array EMI filter, battery chargers and linear shunt regulators. Loss mechanisms in the converter power stage, including switching-time effects in the semiconductor elements, are incorporated into the modeling procedure to provide an accurate representation of the system without requiring frequency-domain measurements to determine the damping factor. The small-signal system model is validated by the use of special measurement techniques which are adapted to the poor signal-to-noise ratio encountered in switching-mode systems. The complete electrical power system with the solar-array EMI filter is shown to be stable over the intended range of operation.
Analysis of detection performance of multi band laser beam analyzer
NASA Astrophysics Data System (ADS)
Du, Baolin; Chen, Xiaomei; Hu, Leili
2017-10-01
Compared with microwave radar, Laser radar has high resolution, strong anti-interference ability and good hiding ability, so it becomes the focus of laser technology engineering application. A large scale Laser radar cross section (LRCS) measurement system is designed and experimentally tested. First, the boundary conditions are measured and the long range laser echo power is estimated according to the actual requirements. The estimation results show that the echo power is greater than the detector's response power. Secondly, a large scale LRCS measurement system is designed according to the demonstration and estimation. The system mainly consists of laser shaping, beam emitting device, laser echo receiving device and integrated control device. Finally, according to the designed lidar cross section measurement system, the scattering cross section of target is simulated and tested. The simulation results are basically the same as the test results, and the correctness of the system is proved.
Wearable knee health rehabilitation assessment using acoustical emissions
NASA Astrophysics Data System (ADS)
Teague, Caitlin N.; Hersek, Sinan; Conant, Jordan L.; Gilliland, Scott M.; Inan, Omer T.
2017-02-01
We have developed a novel, wearable sensing system based on miniature piezoelectric contact microphones for measuring the acoustical emissions from the knee during movement. The system consists of two contact microphones, positioned on the medial and lateral sides of the patella, connected to custom, analog pre-amplifier circuits and a microcontroller for digitization and data storage on a secure digital card. Tn addition to the acoustical sensing, the system includes two integrated inertial measurement sensors including accelerometer and gyroscope modalities to enable joint angle calculations; these sensors, with digital outputs, are connected directly to the same microcontroller. The system provides low noise, accurate joint acoustical emission and angle measurements in a wearable form factor and has several hours of battery life.
[Contrast of Z-Pinch X-Ray Yield Measure Technique].
Li, Mo; Wang, Liang-ping; Sheng, Liang; Lu, Yi
2015-03-01
Resistive bolometer and scintillant detection system are two mainly Z-pinch X-ray yield measure techniques which are based on different diagnostic principles. Contrasting the results from two methods can help with increasing precision of X-ray yield measurement. Experiments with different load material and shape were carried out on the "QiangGuang-I" facility. For Al wire arrays, X-ray yields measured by the two techniques were largely consistent. However, for insulating coating W wire arrays, X-ray yields taken from bolometer changed with load parameters while data from scintillant detection system hardly changed. Simulation and analysis draw conclusions as follows: (1) Scintillant detection system is much more sensitive to X-ray photons with low energy and its spectral response is wider than the resistive bolometer. Thus, results from the former method are always larger than the latter. (2) The responses of the two systems are both flat to Al plasma radiation. Thus, their results are consistent for Al wire array loads. (3) Radiation form planar W wire arrays is mainly composed of sub-keV soft X-ray. X-ray yields measured by the bolometer is supposed to be accurate because of the nickel foil can absorb almost all the soft X-ray. (4) By contrast, using planar W wire arrays, data from scintillant detection system hardly change with load parameters. A possible explanation is that while the distance between wires increases, plasma temperature at stagnation reduces and spectra moves toward the soft X-ray region. Scintillator is much more sensitive to the soft X-ray below 200 eV. Thus, although the total X-ray yield reduces with large diameter load, signal from the scintillant detection system is almost the same. (5) Both Techniques affected by electron beams produced by the loads.
New Constraints on the Abundance of 60Fe in the Early Solar System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trappitsch, Reto; Boehnke, Patrick; Stephan, Thomas
Establishing the abundance of the extinct radionuclide 60Fe (half-life 2.62 Ma) in the early solar system is important for understanding the astrophysical context of solar system formation. While bulk measurements of early solar system phases show a low abundance consistent with galactic background, some in situ measurements by secondary ion mass spectrometry (SIMS) imply a higher abundance, which would require injection from a nearby supernova (SN). In this paper, we present in situ nickel isotopic analyses by resonance ionization mass spectrometry (RIMS) in a chondrule from the primitive meteorite Semarkona (LL3.00). The same chondrule had been previously analyzed by SIMS.more » Despite improved precision compared to SIMS, the RIMS nickel isotopic data do not reveal any resolved excesses of 60Ni that could be unambiguously ascribed to in situ 60Fe decay. Linear regression of 60Ni/ 58Ni versus 56Fe/ 58Ni yields an initial 60Fe/ 56Fe ratio for this chondrule of (3.8 ± 6.9) × 10 -8, which is consistent with both the low initial value found by bulk measurements and the low end of the range of initial ratios inferred from some in situ work. The same regression also gives a solar initial 60Ni/ 58Ni ratio, which shows that this sample was not disturbed by nickel mobilization, thus agreeing with a low initial 60Fe/ 56Fe ratio. These findings agree with a re-evaluation of previous SIMS measurements of the same sample. Finally, supernova injection of 60Fe into the solar system or its parental cloud material is therefore not necessary to account for the measured solar system's initial amount of 60Fe.« less
New Constraints on the Abundance of 60Fe in the Early Solar System
Trappitsch, Reto; Boehnke, Patrick; Stephan, Thomas; ...
2018-04-19
Establishing the abundance of the extinct radionuclide 60Fe (half-life 2.62 Ma) in the early solar system is important for understanding the astrophysical context of solar system formation. While bulk measurements of early solar system phases show a low abundance consistent with galactic background, some in situ measurements by secondary ion mass spectrometry (SIMS) imply a higher abundance, which would require injection from a nearby supernova (SN). In this paper, we present in situ nickel isotopic analyses by resonance ionization mass spectrometry (RIMS) in a chondrule from the primitive meteorite Semarkona (LL3.00). The same chondrule had been previously analyzed by SIMS.more » Despite improved precision compared to SIMS, the RIMS nickel isotopic data do not reveal any resolved excesses of 60Ni that could be unambiguously ascribed to in situ 60Fe decay. Linear regression of 60Ni/ 58Ni versus 56Fe/ 58Ni yields an initial 60Fe/ 56Fe ratio for this chondrule of (3.8 ± 6.9) × 10 -8, which is consistent with both the low initial value found by bulk measurements and the low end of the range of initial ratios inferred from some in situ work. The same regression also gives a solar initial 60Ni/ 58Ni ratio, which shows that this sample was not disturbed by nickel mobilization, thus agreeing with a low initial 60Fe/ 56Fe ratio. These findings agree with a re-evaluation of previous SIMS measurements of the same sample. Finally, supernova injection of 60Fe into the solar system or its parental cloud material is therefore not necessary to account for the measured solar system's initial amount of 60Fe.« less
DOT National Transportation Integrated Search
1982-01-01
A Monostatic Acoustic Vortex Sensing System (MAVSS) was installed at Chicago's O'Hare International Airport to measure the strength and decay of aircraft wake vortices from landing aircraft. The MAVSS consists of an array of acoustic antennas which m...
Development of a wireless air pollution sensor package for aerial-sampling of emissions
A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particulate matter wi...
ERIC Educational Resources Information Center
Marine Corps Inst., Washington, DC.
This course is designed to review the arithmetic skills used by many Marines in the daily pursuance of their duties. It consists of six study units: (1) number systems and operations; (2) fractions and percents; (3) introduction to algebra; (4) units of measurement (considering both the metric and United States systems); (5) geometric forms; and…
21 CFR 866.5560 - Lactic dehydrogenase immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunological test system is a device that consists of the reagents used to measure by immunochemical techniques... found in a variety of conditions, including megaloblastic anemia (decrease in the number of mature red blood cells), myocardial infarction (heart disease), and some forms of leukemia (cancer of the blood...
21 CFR 866.5560 - Lactic dehydrogenase immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... immunological test system is a device that consists of the reagents used to measure by immunochemical techniques... found in a variety of conditions, including megaloblastic anemia (decrease in the number of mature red blood cells), myocardial infarction (heart disease), and some forms of leukemia (cancer of the blood...
21 CFR 866.5560 - Lactic dehydrogenase immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... immunological test system is a device that consists of the reagents used to measure by immunochemical techniques... found in a variety of conditions, including megaloblastic anemia (decrease in the number of mature red blood cells), myocardial infarction (heart disease), and some forms of leukemia (cancer of the blood...
21 CFR 866.5560 - Lactic dehydrogenase immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... immunological test system is a device that consists of the reagents used to measure by immunochemical techniques... found in a variety of conditions, including megaloblastic anemia (decrease in the number of mature red blood cells), myocardial infarction (heart disease), and some forms of leukemia (cancer of the blood...
Clients' Preferences for Small Groups vs. Individual Testing.
ERIC Educational Resources Information Center
Backman, Margaret E.; And Others
Test takers' preferences for group versus individual administration of the Micro-TOWER System of Vocational Evaluation are reported. The system was administered to 211 clients at a vocational rehabilitation center, and consisted of work samples measuring the following job skills: record checking, filing, lamp assembly, message-taking, zip coding,…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Franco, Manuel
The objective of this work was to characterize the neutron irradiation system consisting of americium-241 beryllium (241AmBe) neutron sources placed in a polyethylene shielding for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three recycled 241AmBe sources of different activities that had been combined into a single source. The source in its polyethylene shielding will be used in neutron irradiation testing of components. The characterization of the source-shielding system was necessary to evaluate the radiation environment for future experiments. Characterization of the sourcemore » was also necessary because the documentation for the three component sources and their relative alignment within the Special Form Capsule (SFC) was inadequate. The system consisting of the source and shielding was modeled using Monte Carlo N-Particle transport code (MCNP). The model was validated by benchmarking it against measurements using multiple techniques. To characterize the radiation fields over the full spatial geometry of the irradiation system, it was necessary to use a number of instruments of varying sensitivities. First, the computed photon radiography assisted in determining orientation of the component sources. With the capsule properly oriented inside the shielding, the neutron spectra were measured using a variety of techniques. A N-probe Microspec and a neutron Bubble Dosimeter Spectrometer (BDS) set were used to characterize the neutron spectra/field in several locations. In the third technique, neutron foil activation was used to ascertain the neutron spectra. A high purity germanium (HPGe) detector was used to characterize the photon spectrum. The experimentally measured spectra and the MCNP results compared well. Once the MCNP model was validated to an adequate level of confidence, parametric analyses was performed on the model to optimize for potential experimental configurations and neutron spectra for component irradiation. The final product of this work is a MCNP model validated by measurements, an overall understanding of neutron irradiation system including photon/neutron transport and effective dose rates throughout the system, and possible experimental configurations for future irradiation of components.« less
NASA Technical Reports Server (NTRS)
Williams, R. J.; Mullins, O.
1976-01-01
Details are given for the construction and operation of a 101.3 kN/sq m (1 atmosphere) redox control system. A solid ceramic oxygen electrolyte cell is used to monitor the oxygen fugacity in the furnace. The system consists of a vertical quench, gas mixing furnace with heads designed for mounting the electrolyte cell and with facilities for inserting and removing the samples. The system also contains the high input impedance electronics necessary for measurements, a simplified version of a gas mixing apparatus, and devices for experiments under controlled rates of change relative to temperature and redox state. The calibration and maintenance of the system are discussed.
NASA Technical Reports Server (NTRS)
Williams, R. J.; Mullins, O.
1981-01-01
Details are given for the construction and operation of a 101.3 KN/sq meter (1 atmosphere) redox control system. A solid ceramic oxygen electrolyte cell is used to monitor the oxygen fugacity in the furnace. The system consists of a vertical quench gas mixing furnace with heads designed for mounting the electrolyte cell and with facilities for inserting and removing the samples, a simplified version of a gas mixing apparatus, and devices for experiments under controlled rates of change of temperature. A thermogravimetric analysis system employing these techniques of redox control and measurement is also described. The calibration and maintenance of the system are discussed.
Comparison of Angle of Attack Measurements for Wind Tunnel Testing
NASA Technical Reports Server (NTRS)
Jones, Thomas, W.; Hoppe, John C.
2001-01-01
Two optical systems capable of measuring model attitude and deformation were compared to inertial devices employed to acquire wind tunnel model angle of attack measurements during the sting mounted full span 30% geometric scale flexible configuration of the Northrop Grumman Unmanned Combat Air Vehicle (UCAV) installed in the NASA Langley Transonic Dynamics Tunnel (TDT). The overall purpose of the test at TDT was to evaluate smart materials and structures adaptive wing technology. The optical techniques that were compared to inertial devices employed to measure angle of attack for this test were: (1) an Optotrak (registered) system, an optical system consisting of two sensors, each containing a pair of orthogonally oriented linear arrays to compute spatial positions of a set of active markers; and (2) Video Model Deformation (VMD) system, providing a single view of passive targets using a constrained photogrammetric solution whose primary function was to measure wing and control surface deformations. The Optotrak system was installed for this test for the first time at TDT in order to assess the usefulness of the system for future static and dynamic deformation measurements.
Measuring Critical Care Providers' Attitudes About Controlled Donation After Circulatory Death.
Rodrigue, James R; Luskin, Richard; Nelson, Helen; Glazier, Alexandra; Henderson, Galen V; Delmonico, Francis L
2018-06-01
Unfavorable attitudes and insufficient knowledge about donation after cardiac death among critical care providers can have important consequences for the appropriate identification of potential donors, consistent implementation of donation after cardiac death policies, and relative strength of support for this type of donation. The lack of reliable and valid assessment measures has hampered research to capture providers' attitudes. Design and Research Aims: Using stakeholder engagement and an iterative process, we developed a questionnaire to measure attitudes of donation after cardiac death in critical care providers (n = 112) and examined its psychometric properties. Exploratory factor analysis, internal consistency, and validity analyses were conducted to examine the measure. A 34-item questionnaire consisting of 4 factors (Personal Comfort, Process Satisfaction, Family Comfort, and System Trust) provided the most parsimonious fit. Internal consistency was acceptable for each of the subscales and the total questionnaire (Cronbach α > .70). A strong association between more favorable attitudes overall and knowledge ( r = .43, P < .001) provides evidence of convergent validity. Multivariable regression analyses showed that white race ( P = .002) and more experience with donation after cardiac death ( P < .001) were significant predictors of more favorable attitudes. Study findings support the utility, reliability, and validity of a questionnaire for measuring attitudes in critical care providers and for isolating targets for additional education on donation after cardiac death.
Hierarchical, Three-Dimensional Measurement System for Crime Scene Scanning.
Marcin, Adamczyk; Maciej, Sieniło; Robert, Sitnik; Adam, Woźniak
2017-07-01
We present a new generation of three-dimensional (3D) measuring systems, developed for the process of crime scene documentation. This measuring system facilitates the preparation of more insightful, complete, and objective documentation for crime scenes. Our system reflects the actual requirements for hierarchical documentation, and it consists of three independent 3D scanners: a laser scanner for overall measurements, a situational structured light scanner for more minute measurements, and a detailed structured light scanner for the most detailed parts of tscene. Each scanner has its own spatial resolution, of 2.0, 0.3, and 0.05 mm, respectively. The results of interviews we have conducted with technicians indicate that our developed 3D measuring system has significant potential to become a useful tool for forensic technicians. To ensure the maximum compatibility of our measuring system with the standards that regulate the documentation process, we have also performed a metrological validation and designated the maximum permissible length measurement error E MPE for each structured light scanner. In this study, we present additional results regarding documentation processes conducted during crime scene inspections and a training session. © 2017 American Academy of Forensic Sciences.
Measurement system for nitrous oxide based on amperometric gas sensor
NASA Astrophysics Data System (ADS)
Siswoyo, S.; Persaud, K. C.; Phillips, V. R.; Sneath, R.
2017-03-01
It has been well known that nitrous oxide is an important greenhouse gas, so monitoring and control of its concentration and emission is very important. In this work a nitrous oxide measurement system has been developed consisting of an amperometric sensor and an appropriate lab-made potentiostat that capable measuring picoampere current ranges. The sensor was constructed using a gold microelectrode as working electrode surrounded by a silver wire as quasi reference electrode, with tetraethyl ammonium perchlorate and dimethylsulphoxide as supporting electrolyte and solvent respectively. The lab-made potentiostat was built incorporating a transimpedance amplifier capable of picoampere measurements. This also incorporated a microcontroller based data acquisition system, controlled by a host personal computer using a dedicated computer program. The system was capable of detecting N2O concentrations down to 0.07 % v/v.
Estimating subglottal pressure via airflow interruption with auditory masking.
Hoffman, Matthew R; Jiang, Jack J
2009-11-01
Current noninvasive measurement of subglottal pressure using airflow interruption often produces inconsistent results due to the elicitation of audio-laryngeal reflexes. Auditory feedback could be considered as a means of ensuring measurement accuracy and precision. The purpose of this study was to determine if auditory masking could be used with the airflow interruption system to improve intrasubject consistency. A prerecorded sample of subject phonation was played on a loop over headphones during the trials with auditory masking. This provided subjects with a target pitch and blocked out distracting ambient noise created by the airflow interrupter. Subglottal pressure was noninvasively measured using the airflow interruption system. Thirty subjects, divided into two equal groups, performed 10 trials without auditory masking and 10 trials with auditory masking. Group one performed the normal trials first, followed by the trials with auditory masking. Group two performed the auditory masking trials first, followed by the normal trials. Intrasubject consistency was improved by adding auditory masking, resulting in a decrease in average intrasubject standard deviation from 0.93+/-0.51 to 0.47+/-0.22 cm H(2)O (P < 0.001). Auditory masking can be used effectively to combat audio-laryngeal reflexes and aid subjects in maintaining constant glottal configuration and frequency, thereby increasing intrasubject consistency when measuring subglottal pressure. By considering auditory feedback, a more reliable method of measurement was developed. This method could be used by clinicians, as reliable, immediately available values of subglottal pressure are useful in evaluating laryngeal health and monitoring treatment progress.
Solid state high resolution multi-spectral imager CCD test phase
NASA Technical Reports Server (NTRS)
1973-01-01
The program consisted of measuring the performance characteristics of charge coupled linear imaging devices, and a study defining a multispectral imaging system employing advanced solid state photodetection techniques.
A Parkinson's disease measurement system using laser lines and a CMOS image sensor.
Chang, Rong-Seng; Chiu, Jen-Hwey; Chen, Fang-Pey; Chen, Jyh-Cheng; Yang, Jen-Lin
2011-01-01
This paper presents a non-invasive, non-contact system for the measurement of the arterial dorsum manus vibration waveforms of Parkinson disease patients. The laser line method is applied to detect the dorsum manus vibration in rest and postural situations. The proposed measurement system mainly consists of a laser diode and a low cost complementary metal-oxide semiconductor (CMOS) image sensor. Laser line and centroid methods are combined with the Fast Fourier Transform (FFT) in this study. The shape and frequency and relative frequency of the dorsum manus vibration waveforms can be detected rapidly using our Parkinson's disease measurement system. A laser line near the wrist joint is used as the testing line. The experimental results show an obvious increase in the amplitude and frequency of dorsum manus variation in the measured region in patients suffering from Parkinson's disease, indicating the obvious effects of the disease. Both in postural and rest state measurements, as the patient disease age increases the vibration frequency increases. The measurement system is well suited for evaluating and pre-diagnosing early stage Parkinson's disease.
Assessment of meteorological uncertainties as they apply to the ASCENDS mission
NASA Astrophysics Data System (ADS)
Snell, H. E.; Zaccheo, S.; Chase, A.; Eluszkiewicz, J.; Ott, L. E.; Pawson, S.
2011-12-01
Many environment-oriented remote sensing and modeling applications require precise knowledge of the atmospheric state (temperature, pressure, water vapor, surface pressure, etc.) on a fine spatial grid with a comprehensive understanding of the associated errors. Coincident atmospheric state measurements may be obtained via co-located remote sensing instruments or by extracting these data from ancillary models. The appropriate technique for a given application depends upon the required accuracy. State-of-the-art mesoscale/regional numerical weather prediction (NWP) models operate on spatial scales of a few kilometers resolution, and global scale NWP models operate on scales of tens of kilometers. Remote sensing measurements may be made on spatial scale comparable to the measurement of interest. These measurements normally require a separate sensor, which increases the overall size, weight, power and complexity of the satellite payload. Thus, a comprehensive understanding of the errors associated with each of these approaches is a critical part of the design/characterization of a remote-sensing system whose measurement accuracy depends on knowledge of the atmospheric state. One of the requirements as part of the overall ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons) mission development is to develop a consistent set of atmospheric state variables (vertical temperature and water vapor profiles, and surface pressure) for use in helping to constrain overall retrieval error budget. If the error budget requires tighter uncertainties on ancillary atmospheric parameters than can be provided by NWP models and analyses, additional sensors may be required to reduce the overall measurement error and meet mission requirements. To this end we have used NWP models and reanalysis information to generate a set of atmospheric profiles which contain reasonable variability. This data consists of a "truth" set and a companion "measured" set of profiles. The truth set contains climatologically-relevant profiles of pressure, temperature and humidity with an accompanying surface pressure. The measured set consists of some number of instances of the truth set which have been perturbed to represent realistic measurement uncertainty for the truth profile using measurement error covariance matrices. The primary focus has been to develop matrices derived using information about the profile retrieval accuracy as documented for on-orbit sensor systems including AIRS, AMSU, ATMS, and CrIS. Surface pressure variability and uncertainty was derived from globally-compiled station pressure information. We generated an additional measurement set of profiles which represent the overall error within NWP models. These profile sets will allow for comprehensive trade studies for sensor system design and provide a basis for setting measurement requirements for co-located temperature, humidity sounders, determine the utility of NWP data to either replace or supplement collocated measurements, and to assess the overall end-to-end system performance of the sensor system. In this presentation we discuss the process by which we created these data sets and show their utility in performing trade studies for sensor system concepts and designs.
Prototype of NASA's Global Precipitation Measurement Mission Ground Validation System
NASA Technical Reports Server (NTRS)
Schwaller, M. R.; Morris, K. R.; Petersen, W. A.
2007-01-01
NASA is developing a Ground Validation System (GVS) as one of its contributions to the Global Precipitation Mission (GPM). The GPM GVS provides an independent means for evaluation, diagnosis, and ultimately improvement of GPM spaceborne measurements and precipitation products. NASA's GPM GVS consists of three elements: field campaigns/physical validation, direct network validation, and modeling and simulation. The GVS prototype of direct network validation compares Tropical Rainfall Measuring Mission (TRMM) satellite-borne radar data to similar measurements from the U.S. national network of operational weather radars. A prototype field campaign has also been conducted; modeling and simulation prototypes are under consideration.
MEMS piezoresistive cantilever for the direct measurement of cardiomyocyte contractile force
NASA Astrophysics Data System (ADS)
Matsudaira, Kenei; Nguyen, Thanh-Vinh; Hirayama Shoji, Kayoko; Tsukagoshi, Takuya; Takahata, Tomoyuki; Shimoyama, Isao
2017-10-01
This paper reports on a method to directly measure the contractile forces of cardiomyocytes using MEMS (micro electro mechanical systems)-based force sensors. The fabricated sensor chip consists of piezoresistive cantilevers that can measure contractile forces with high frequency (several tens of kHz) and high sensing resolution (less than 0.1 nN). Moreover, the proposed method does not require a complex observation system or image processing, which are necessary in conventional optical-based methods. This paper describes the design, fabrication, and evaluation of the proposed device and demonstrates the direct measurements of contractile forces of cardiomyocytes using the fabricated device.
Reliability measurement during software development. [for a multisensor tracking system
NASA Technical Reports Server (NTRS)
Hecht, H.; Sturm, W. A.; Trattner, S.
1977-01-01
During the development of data base software for a multi-sensor tracking system, reliability was measured. The failure ratio and failure rate were found to be consistent measures. Trend lines were established from these measurements that provided good visualization of the progress on the job as a whole as well as on individual modules. Over one-half of the observed failures were due to factors associated with the individual run submission rather than with the code proper. Possible application of these findings for line management, project managers, functional management, and regulatory agencies is discussed. Steps for simplifying the measurement process and for use of these data in predicting operational software reliability are outlined.
NASA participation in the 1980 PEPE/NEROS project: Data archive
NASA Technical Reports Server (NTRS)
Brewer, D. A.; Remsberg, E. E.; Loar, G. R.; Bendura, R. J.
1982-01-01
Eight experimental air quality measurement systems were investigated during July and August 1980 as part of the EPA PEPE/NEROS fiel measurement program. Data from those efforts have been entered into an archive that may be accessed by other researchers. The data sets consists of airborne measurements of regional mixed layer heights and aerosol and ozone distributions as well as point measurements of meteorological parameters and ozone obtained during diurnal transitions in the planetary boundary layer. This report gives a discussion of each measurement system, a preliminary assessment of data quality, a description of the archive format for each data set, and a summary of several proposed scientific studies which will utilize these data.
An Automated and Continuous Plant Weight Measurement System for Plant Factory
Chen, Wei-Tai; Yeh, Yu-Hui F.; Liu, Ting-Yu; Lin, Ta-Te
2016-01-01
In plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator. Traditional plant weight measurements are destructive and laborious. In order to measure and record the plant weight during plant growth, an automated measurement system was designed and developed herein. The weight measurement system comprises a weight measurement device and an imaging system. The weight measurement device consists of a top disk, a bottom disk, a plant holder and a load cell. The load cell with a resolution of 0.1 g converts the plant weight on the plant holder disk to an analog electrical signal for a precise measurement. The top disk and bottom disk are designed to be durable for different plant sizes, so plant weight can be measured continuously throughout the whole growth period, without hindering plant growth. The results show that plant weights measured by the weight measurement device are highly correlated with the weights estimated by the stereo-vision imaging system; hence, plant weight can be measured by either method. The weight growth of selected vegetables growing in the National Taiwan University plant factory were monitored and measured using our automated plant growth weight measurement system. The experimental results demonstrate the functionality, stability and durability of this system. The information gathered by this weight system can be valuable and beneficial for hydroponic plants monitoring research and agricultural research applications. PMID:27066040
An Automated and Continuous Plant Weight Measurement System for Plant Factory.
Chen, Wei-Tai; Yeh, Yu-Hui F; Liu, Ting-Yu; Lin, Ta-Te
2016-01-01
In plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator. Traditional plant weight measurements are destructive and laborious. In order to measure and record the plant weight during plant growth, an automated measurement system was designed and developed herein. The weight measurement system comprises a weight measurement device and an imaging system. The weight measurement device consists of a top disk, a bottom disk, a plant holder and a load cell. The load cell with a resolution of 0.1 g converts the plant weight on the plant holder disk to an analog electrical signal for a precise measurement. The top disk and bottom disk are designed to be durable for different plant sizes, so plant weight can be measured continuously throughout the whole growth period, without hindering plant growth. The results show that plant weights measured by the weight measurement device are highly correlated with the weights estimated by the stereo-vision imaging system; hence, plant weight can be measured by either method. The weight growth of selected vegetables growing in the National Taiwan University plant factory were monitored and measured using our automated plant growth weight measurement system. The experimental results demonstrate the functionality, stability and durability of this system. The information gathered by this weight system can be valuable and beneficial for hydroponic plants monitoring research and agricultural research applications.
Development of a highly automated system for the remote evaluation of individual tree parameters
Richard Pollock
2000-01-01
A highly-automated procedure for remotely estimating individual tree location, crown diameter, species class, and height has been developed. This procedure will involve the use of a multimodal airborne sensing system that consists of a digital frame camera, a scanning laser rangefinder, and a position and orientation measurement system. Data from the multimodal sensing...
ERIC Educational Resources Information Center
Rosenkränzer, Frank; Kramer, Tim; Hörsch, Christian; Schuler, Stephan; Rieß, Werner
2016-01-01
The understanding of complex, dynamic and animate systems has a special standing in education for sustainable development and biology. Thus one important role of science teacher education is to promote student teachers' Content Related Knowledge (CRK) for teaching systems thinking, consisting of extensive Content Knowledge (CK) and well formed…
Expert system for analyzing eddy current measurements
Levy, Arthur J.; Oppenlander, Jane E.; Brudnoy, David M.; Englund, James M.; Loomis, Kent C.
1994-01-01
A method and apparatus (called DODGER) analyzes eddy current data for heat exchanger tubes or any other metallic object. DODGER uses an expert system to analyze eddy current data by reasoning with uncertainty and pattern recognition. The expert system permits DODGER to analyze eddy current data intelligently, and obviate operator uncertainty by analyzing the data in a uniform and consistent manner.
Evaluating iPhone recordings for acoustic voice assessment.
Lin, Emily; Hornibrook, Jeremy; Ormond, Tika
2012-01-01
This study examined the viability of using iPhone recordings for acoustic measurements of voice quality. Acoustic measures were compared between voice signals simultaneously recorded from 11 normal speakers (6 females and 5 males) through an iPhone (model A1303, Apple, USA) and a comparison recording system. Comparisons were also conducted between the pre- and post-operative voices recorded from 10 voice patients (4 females and 6 males) through the iPhone. Participants aged between 27 and 79 years. Measures from iPhone and comparison signals were found to be highly correlated. Findings of the effects of vowel type on the selected measures were consistent between the two recording systems and congruent with previous findings. Analysis of the patient data revealed that a selection of acoustic measures, such as vowel space area and voice perturbation measures, consistently demonstrated a positive change following phonosurgery. The present findings indicated that the iPhone device tested was useful for tracking voice changes for clinical management. Preliminary findings regarding factors such as gender and type of pathology suggest that intra-subject, instead of norm-referenced, comparisons of acoustic measures would be more useful in monitoring the progression of a voice disorder or tracking the treatment effect. Copyright © 2012 S. Karger AG, Basel.
High resolution imaging of a subsonic projectile using automated mirrors with large aperture
NASA Astrophysics Data System (ADS)
Tateno, Y.; Ishii, M.; Oku, H.
2017-02-01
Visual tracking of high-speed projectiles is required for studying the aerodynamics around the objects. One solution to this problem is a tracking method based on the so-called 1 ms Auto Pan-Tilt (1ms-APT) system that we proposed in previous work, which consists of rotational mirrors and a high-speed image processing system. However, the images obtained with that system did not have high enough resolution to realize detailed measurement of the projectiles because of the size of the mirrors. In this study, we propose a new system consisting of enlarged mirrors for tracking a high-speed projectiles so as to achieve higher-resolution imaging, and we confirmed the effectiveness of the system via an experiment in which a projectile flying at subsonic speed tracked.
NASA Astrophysics Data System (ADS)
Welch, Kyle; Liebman-Pelaez, Alexander; Corwin, Eric
Equilibrium statistical mechanics is traditionally limited to thermal systems. Can it be applied to athermal, non-equilibrium systems that nonetheless satisfy the basic criteria of steady-state chaos and isotropy? We answer this question using a macroscopic system of chaotic surface waves which is, by all measures, non-equilibrium. The waves are generated in a dish of water that is vertically oscillated above a critical amplitude. We have constructed a rheometer that actively measures the drag imparted by the waves on a buoyant particle, a quantity entirely divorced in origin from the drag imparted by the fluid in which the particle floats. We also perform a separate, passive measurement, extracting a diffusion constant and effective temperature. Having directly measured all three properties (temperature, diffusion constant, and drag coefficient) we go on to show that our macroscopic, non-equilibrium case is wholly consistent with the Einstein relation, a classic result for equilibrium thermal systems.
Telerobotic system performance measurement - Motivation and methods
NASA Technical Reports Server (NTRS)
Kondraske, George V.; Khoury, George J.
1992-01-01
A systems performance-based strategy for modeling and conducting experiments relevant to the design and performance characterization of telerobotic systems is described. A developmental testbed consisting of a distributed telerobotics network and initial efforts to implement the strategy described is presented. Consideration is given to the general systems performance theory (GSPT) to tackle human performance problems as a basis for: measurement of overall telerobotic system (TRS) performance; task decomposition; development of a generic TRS model; and the characterization of performance of subsystems comprising the generic model. GSPT employs a resource construct to model performance and resource economic principles to govern the interface of systems to tasks. It provides a comprehensive modeling/measurement strategy applicable to complex systems including both human and artificial components. Application is presented within the framework of a distributed telerobotics network as a testbed. Insight into the design of test protocols which elicit application-independent data is described.
A Measure of Maintenance Training/Qualification Readiness and Its Impact on Billet Life Cycle Coast.
1983-09-01
MAINTENANCE READINESS ESTIMATION---------------- 24 A. AVIATION TRAINING SUPPORT SYSTEM ---- 25 B. MAINTENANCE MATRIX UTILIZATION-------------- 27 C...nonexistent follow-on training programs. CRef. 13 The operation and maintenance o systems account for a major portion of system life cycle cost. Studies of... systems annual support costs show that manpower consistently consuwme over half of the funds appropriated for operation and maintenance of the system £Ref
NASA Technical Reports Server (NTRS)
Oran, W. A.; Reiss, D. A.; Berge, L. H.; Parker, H. W.
1979-01-01
The acoustic fields and levitation forces produced along the axis of a single-axis resonance system were measured. The system consisted of a St. Clair generator and a planar reflector. The levitation force was measured for bodies of various sizes and geometries (i.e., spheres, cylinders, and discs). The force was found to be roughly proportional to the volume of the body until the characteristic body radius reaches approximately 2/k (k = wave number). The acoustic pressures along the axis were modeled using Huygens principle and a method of imaging to approximate multiple reflections. The modeled pressures were found to be in reasonable agreement with those measured with a calibrated microphone.
Optical stretching as a tool to investigate the mechanical properties of lipid bilayers.
Solmaz, Mehmet E; Sankhagowit, Shalene; Biswas, Roshni; Mejia, Camilo A; Povinelli, Michelle L; Malmstadt, Noah
2013-10-07
Measurements of lipid bilayer bending modulus by various techniques produce widely divergent results. We attempt to resolve some of this ambiguity by measuring bending modulus in a system that can rapidly process large numbers of samples, yielding population statistics. This system is based on optical stretching of giant unilamellar vesicles (GUVs) in a microfluidic dual-beam optical trap (DBOT). The microfluidic DBOT system is used here to measure three populations of GUVs with distinct lipid compositions. We find that gel-phase membranes are significantly stiffer than liquid-phase membranes, consistent with previous reports. We also find that the addition of cholesterol does not alter the bending modulus of membranes composed of a monounsaturated phospholipid.
Measuring and monitoring IT using a balanced scorecard approach.
Gash, Deborah J; Hatton, Todd
2007-01-01
Ensuring that the information technology department is aligned with the overall health system strategy and is performing at a consistently high level is a priority at Saint Luke's Health System in Kansas City, Mo. The information technology department of Saint Luke's Health System has been using the balanced scorecard approach described in this article to measure and monitor its performance for four years. This article will review the structure of the IT department's scorecard; the categories and measures used; how benchmarks are determined; how linkage to the organizational scorecard is made; how results are reported; how changes are made to the scorecard; and tips for using a scorecard in other IT departments.
Relative gravimeter prototype based on micro electro mechanical system
NASA Astrophysics Data System (ADS)
Rozy, A. S. A.; Nugroho, H. A.; Yusuf, M.
2018-03-01
This research to make gravity measurement system by utilizing micro electro mechanical system based sensor in Gal order. System design consists of three parts, design of hardware, software, and interface. The design of the hardware include of designing the sensor design to measure the value of a stable gravity acceleration. The ADXL345 and ADXL335 sensors are tuned to obtain stable measurements. The design of the instrumentation system the next stage by creating a design to integrate between the sensor, microcontroller, and GPS. The design of programming algorithm is done with Arduino IDE software. The interface design uses a 20x4 LCD display to display the gravity acceleration value and store data on the storage media. The system uses a box made of iron and plate leveling to minimize measurement errors. The sensor test shows the ADXL345 sensor has a more stable value. The system is examined by comparing with gravity measurement of gravimeter A-10 results in Bandung observation post. The result of system test resulted the average of system correction value equal to 0.19 Gal. The system is expected to use for mineral exploration, water supply analyze, and earthquake precursor.
Warren B. Cohen; Hans-Erik Andersen; Sean P. Healey; Gretchen G. Moisen; Todd A. Schroeder; Christopher W. Woodall; Grant M. Domke; Zhiqiang Yang; Robert E. Kennedy; Stephen V. Stehman; Curtis Woodcock; Jim Vogelmann; Zhe Zhu; Chengquan Huang
2015-01-01
We are developing a system that provides temporally consistent biomass estimates for national greenhouse gas inventory reporting to the United Nations Framework Convention on Climate Change. Our model-assisted estimation framework relies on remote sensing to scale from plot measurements to lidar strip samples, to Landsat time series-based maps. As a demonstration, new...
Calibrating a novel multi-sensor physical activity measurement system.
John, D; Liu, S; Sasaki, J E; Howe, C A; Staudenmayer, J; Gao, R X; Freedson, P S
2011-09-01
Advancing the field of physical activity (PA) monitoring requires the development of innovative multi-sensor measurement systems that are feasible in the free-living environment. The use of novel analytical techniques to combine and process these multiple sensor signals is equally important. This paper describes a novel multi-sensor 'integrated PA measurement system' (IMS), the lab-based methodology used to calibrate the IMS, techniques used to predict multiple variables from the sensor signals, and proposes design changes to improve the feasibility of deploying the IMS in the free-living environment. The IMS consists of hip and wrist acceleration sensors, two piezoelectric respiration sensors on the torso, and an ultraviolet radiation sensor to obtain contextual information (indoors versus outdoors) of PA. During lab-based calibration of the IMS, data were collected on participants performing a PA routine consisting of seven different ambulatory and free-living activities while wearing a portable metabolic unit (criterion measure) and the IMS. Data analyses on the first 50 adult participants are presented. These analyses were used to determine if the IMS can be used to predict the variables of interest. Finally, physical modifications for the IMS that could enhance the feasibility of free-living use are proposed and refinement of the prediction techniques is discussed.
NASA Astrophysics Data System (ADS)
Pinker, R. T.; Ma, Y.; Nussbaumer, E. A.
2012-04-01
The overall goal of the MEaSUREs activity titled: "Developing Consistent Earth System Data Records for the Global Terrestrial Water Cycle" is to develop consistent, long-term Earth System Data Records (ESDRs) for the major components of the terrestrial water cycle at a climatic time scale. The shortwave (SW) and longwave (LW) radiative fluxes at the Earth's surface determine the exchange of energy between the land and the atmosphere are the focus of this presentation. During the last two decades, significant progress has been made in assessing the Earth Radiation Balance from satellite observations. Yet, satellite based estimates differ from each other and long term satellite observations at global scale are not readily available. There is a need to utilize existing records of satellite observations and to improve currently available estimates. This paper reports on improvements introduced to an existing methodology to estimate shortwave (SW) radiative fluxes within the atmospheric system, on the development of a new inference scheme for deriving LW fluxes, the implementation of the approach with the ISCCP DX observations and improved atmospheric inputs for the period of 1983-2007, evaluation against ground observations, and comparison with independent satellite methods and numerical models. The resulting ESDRs from the entire MEaSUREs Project are intended to provide a consistent basis for estimating the mean state and variability of the land surface water cycle at a spatial scale relevant to major global river basins. MEaSUREs Project "Developing Consistent Earth System Data Records for the Global Terrestrial Water Cycle" Team Members: E. F. Wood (PI)1, T. J Bohn2, J. L Bytheway3, X. Feng4, H. Gao2, P. R.Houser4 (CO-I), C. D Kummerow3 (CO-I), D. P Lettenmaier2 (CO-I), C. Li5, Y. Ma5, R. F MacCracken4, M. Pan1, R. T Pinker5 (CO-I), A. K. Sahoo1, J. Sheffield1 1. Dept of CEE, Princeton University, Princeton, NJ, USA. 2. Dept of CEE, University of Washington, Seattle, WA, USA. 3. Dept of Atmospheric Science, Fort Collins, CO, USA. 4. Dept of Geography and GeoInformation Scie., George Mason University, Fairfax, VA, USA. 5. Dept of Meteorology, University of Maryland, College Park, MD, USA.
A complex network-based importance measure for mechatronics systems
NASA Astrophysics Data System (ADS)
Wang, Yanhui; Bi, Lifeng; Lin, Shuai; Li, Man; Shi, Hao
2017-01-01
In view of the negative impact of functional dependency, this paper attempts to provide an alternative importance measure called Improved-PageRank (IPR) for measuring the importance of components in mechatronics systems. IPR is a meaningful extension of the centrality measures in complex network, which considers usage reliability of components and functional dependency between components to increase importance measures usefulness. Our work makes two important contributions. First, this paper integrates the literature of mechatronic architecture and complex networks theory to define component network. Second, based on the notion of component network, a meaningful IPR is brought into the identifying of important components. In addition, the IPR component importance measures, and an algorithm to perform stochastic ordering of components due to the time-varying nature of usage reliability of components and functional dependency between components, are illustrated with a component network of bogie system that consists of 27 components.
Analysis of particle in liquid using excitation-fluorescence spectral flow cytometer
NASA Astrophysics Data System (ADS)
Takenaka, Kei; Togashi, Shigenori
2018-01-01
We have developed a new flow cytometer that can measure the excitation-fluorescence spectra of a single particle. This system consists of a solution-transmitting unit and an optical unit. The solution-transmitting unit allows a sample containing particles to flow through the center of a flow cell by hydrodynamic focusing. The optical unit irradiates particles with dispersed white light (wavelength band: 400-650 nm) along the flow direction and measures their fluorescence spectra (wavelength band: 400-700 nm) using a spectroscopic photodetector array. The fluorescence spectrum of a particle changes with the shift of the wavelength of the excitation light. Using this system, the excitation-fluorescence spectra of a fluorescent particle were measured. Additionally, a homogenized tomato suspension and a homogenized spinach suspension were measured using the system. Measurement results show that it is possible to determine the components of vegetables by comparing measured fluorescence spectra of particles in a vegetable suspension.
Full-field 3D shape measurement of specular object having discontinuous surfaces
NASA Astrophysics Data System (ADS)
Zhang, Zonghua; Huang, Shujun; Gao, Nan; Gao, Feng; Jiang, Xiangqian
2017-06-01
This paper presents a novel Phase Measuring Deflectometry (PMD) method to measure specular objects having discontinuous surfaces. A mathematical model is established to directly relate the absolute phase and depth, instead of the phase and gradient. Based on the model, a hardware measuring system has been set up, which consists of a precise translating stage, a projector, a diffuser and a camera. The stage locates the projector and the diffuser together to a known position during measurement. By using the model-based and machine vision methods, system calibration is accomplished to provide the required parameters and conditions. The verification tests are given to evaluate the effectiveness of the developed system. 3D (Three-Dimensional) shapes of a concave mirror and a monolithic multi-mirror array having multiple specular surfaces have been measured. Experimental results show that the proposed method can obtain 3D shape of specular objects having discontinuous surfaces effectively
Stochastic sensitivity measure for mistuned high-performance turbines
NASA Technical Reports Server (NTRS)
Murthy, Durbha V.; Pierre, Christophe
1992-01-01
A stochastic measure of sensitivity is developed in order to predict the effects of small random blade mistuning on the dynamic aeroelastic response of turbomachinery blade assemblies. This sensitivity measure is based solely on the nominal system design (i.e., on tuned system information), which makes it extremely easy and inexpensive to calculate. The measure has the potential to become a valuable design tool that will enable designers to evaluate mistuning effects at a preliminary design stage and thus assess the need for a full mistuned rotor analysis. The predictive capability of the sensitivity measure is illustrated by examining the effects of mistuning on the aeroelastic modes of the first stage of the oxidizer turbopump in the Space Shuttle Main Engine. Results from a full analysis mistuned systems confirm that the simple stochastic sensitivity measure predicts consistently the drastic changes due to misturning and the localization of aeroelastic vibration to a few blades.
NASA Astrophysics Data System (ADS)
Kim, Younsu; Kim, Sungmin; Boctor, Emad M.
2017-03-01
An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.
A comparison of TPS and different measurement techniques in small-field electron beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donmez Kesen, Nazmiye, E-mail: nazo94@gmail.com; Cakir, Aydin; Okutan, Murat
In recent years, small-field electron beams have been used for the treatment of superficial lesions, which requires small circular fields. However, when using very small electron fields, some significant dosimetric problems may occur. In this study, dose distributions and outputs of circular fields with dimensions of 5 cm and smaller, for nominal energies of 6, 9, and 15 MeV from the Siemens ONCOR Linac, were measured and compared with data from a treatment planning system using the pencil-beam algorithm in electron beam calculations. All dose distribution measurements were performed using the Gafchromic EBT film; these measurements were compared with datamore » that were obtained from the Computerized Medical Systems (CMS) XiO treatment planning system (TPS), using the gamma-index method in the PTW VeriSoft software program. Output measurements were performed using the Gafchromic EBT film, an Advanced Markus ion chamber, and thermoluminescent dosimetry (TLD). Although the pencil-beam algorithm is used to model electron beams in many clinics, there is no substantial amount of detailed information in the literature about its use. As the field size decreased, the point of maximum dose moved closer to the surface. Output factors were consistent; differences from the values obtained from the TPS were, at maximum, 42% for 6 and 15 MeV and 32% for 9 MeV. When the dose distributions from the TPS were compared with the measurements from the Gafchromic EBT films, it was observed that the results were consistent for 2-cm diameter and larger fields, but the outputs for fields of 1-cm diameter and smaller were not consistent. In CMS XiO TPS, calculated using the pencil-beam algorithm, the dose distributions of electron treatment fields that were created with circular cutout of a 1-cm diameter were not appropriate for patient treatment and the pencil-beam algorithm is not convenient for monitor unit (MU) calculations in electron dosimetry.« less
Nagai, Kanto; Hoshino, Yuichi; Nishizawa, Yuichiro; Araki, Daisuke; Matsushita, Takehiko; Matsumoto, Tomoyuki; Takayama, Koji; Nagamune, Kouki; Kurosaka, Masahiro; Kuroda, Ryosuke
2015-10-01
Tibial acceleration during the pivot shift test is a potential quantitative parameter to evaluate rotational laxity of anterior cruciate ligament (ACL) insufficiency. However, clinical application of this measurement has not been fully examined. This study aimed to measure and compare tibial acceleration before and after ACL reconstruction (ACLR) in ACL-injured patients. We hypothesized tibial acceleration would be reduced by ACLR and tibial acceleration would be consistent in the same knee at different time points. Seventy ACL-injured patients who underwent ACLR were enrolled. Tibial acceleration during the pivot shift test was measured using an electromagnetic measurement system before ALCR and at the second-look arthroscopy 1 year post-operatively. Tibial acceleration was compared to clinical grading and between ACL-injured/ACL-reconstructed and contralateral knees. Pre-operative tibial acceleration was increased stepwise with the increase in clinical grading (P < 0.01). Tibial acceleration in ACL-injured knee (1.9 ± 1.2 m/s(2)) was larger than that in the contralateral knee (0.8 ± 0.3 m/s(2), P < 0.01), and reduced to 0.9 ± 0.3 m/s(2) post-operatively (P < 0.01). There was no difference between ACL-reconstructed and contralateral knee (n.s.). Tibial acceleration in contralateral knees was consistent pre- and post-operatively (n.s.). Tibial acceleration measurement demonstrated increased rotational laxity in ACL-injured knees and its reduction by ALCR. Additionally, consistent measurements were obtained in ACL-intact knees at different time points. Therefore, tibial acceleration during the pivot shift test could provide quantitative evaluation of rotational stability before and after ACL reconstruction. III.
NASA Astrophysics Data System (ADS)
Iyengar, A.; Beach, M.; Newby, R. J.; Fabris, L.; Heilbronn, L. H.; Hayward, J. P.
2015-02-01
Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee, USA. The 0.5 m2 system, consisting of eight EJ-301 liquid scintillation detectors, was used to collect neutron background measurements in order to better understand the systematic variations in background that depend solely on the street-level measurement position in a downtown area. Data was collected along 5 different streets, and the measurements were found to be repeatable. Using 10-min measurements, the fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reduction in background count rates ranging from 10% to 50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the net shielding of the cosmic ray neutron flux by adjacent buildings. For reference, the building structure as observed at street level is quantified in part here by a measured angle-of-open-sky metric.
A system for the measurement of delayed neutrons and gammas from special nuclear materials
Andrews, M. T.; Corcoran, E. C.; Goorley, J. T.; ...
2014-11-27
The delayed neutron counting (DNC) system at the Royal Military College of Canada has been upgraded to accommodate concurrent delayed neutron and gamma measurements. This delayed neutron and gamma counting (DNGC) system uses a SLOWPOKE-2 reactor to irradiate fissile materials before their transfer to a counting arrangement consisting of six ³He and one HPGe detector. The application of this system is demonstrated in an example where delayed neutron and gamma emissions are used in complement to examine ²³³U content and determine fissile mass with an average relative error and accuracy of -2.2 and 1.5 %, respectively.
NASA Astrophysics Data System (ADS)
Arciniegas, Javier R.; González, Andrés. L.; Quintero, L. A.; Contreras, Carlos R.; Meneses, Jaime E.
2014-05-01
Three-dimensional shape measurement is a subject that consistently produces high scientific interest and provides information for medical, industrial and investigative applications, among others. In this paper, it is proposed to implement a three-dimensional (3D) reconstruction system for applications in superficial inspection of non-metallic pipes for the hydrocarbons transport. The system is formed by a CCD camera, a video-projector and a laptop and it is based on fringe projection technique. System functionality is evidenced by evaluating the quality of three-dimensional reconstructions obtained, which allow observing the failures and defects on the study object surface.
NASA Technical Reports Server (NTRS)
Barranger, J. P.
1978-01-01
The rotor blade tip clearance measurement system consists of a capacitance sensing probe with self contained tuning elements, a connecting coaxial cable, and remotely located electronics. Tests show that the accuracy of the system suffers from a strong dependence on probe tip temperature and humidity. A novel inplace recalibration technique was presented which partly overcomes this problem through a simple modification of the electronics that permits a scale factor correction. This technique, when applied to a commercial system significantly reduced errors under varying conditions of humidity and temperature. Equations were also found that characterize the important cable and probe design quantities.
Cotton-Mouton polarimeter with HCN laser on CHS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akiyama, T.; Kawahata, K.; Ito, Y.
Polarimeters based on the Cotton-Mouton effect hold promise for electron density measurements. We have designed and installed a Cotton-Mouton polarimeter on the Compact Helical System. The Cotton-Mouton effect is measured as the phase difference between probe and reference beams. In this system, an interferometric measurement can be performed simultaneously with the same probe chord. The light source is a HCN laser (wavelength of 337 {mu}m). Digital complex demodulation is adopted for small phase analysis. The line averaged density evaluated from the polarimeter along a plasma center chord is almost consistent with that from the interferometer.
Laser Doppler Measurement of Atmopsheric Wind Velocity
NASA Technical Reports Server (NTRS)
Schwiesow, R. L.; Abshire, N. L.; Derr, V. E.
1973-01-01
Our presentation consists of two parts: (1) a summary review of laser Doppler principles and applications, and (2) operational design and preliminary laboratory tests of a CO2 laser system for NOAA applications.
Intranet and Internet metrological workstation with photonic sensors and transmission
NASA Astrophysics Data System (ADS)
Romaniuk, Ryszard S.; Pozniak, Krzysztof T.; Dybko, Artur
1999-05-01
We describe in this paper a part of a telemetric network which consists of a workstation with photonic measurement and communication interfaces, structural fiber optic cabling (10/100BaseFX and CAN-FL), and photonic sensors with fiber optic interfaces. The station is equipped with direct photonic measurement interface and most common measuring standards converter (RS, GPIB) with fiber optic I/O CAN bus, O/E converters, LAN and modem ports. The station was connected to the Intranet (ipx/spx) and Internet (tcp/ip) with separate IP number and DNS, WINS names. Virtual measuring environment system program was written specially for such an Intranet and Internet station. The measurement system program communicated with the user via a Graphical User's Interface (GUI). The user has direct access to all functions of the measuring station system through appropriate layers of GUI: telemetric, transmission, visualization, processing, information, help and steering of the measuring system. We have carried out series of thorough simulation investigations and tests of the station using WWW subsystem of the Internet. We logged into the system through the LAN and via modem. The Internet metrological station works continuously under the address http://nms.ipe.pw.edu.pl/nms. The station and the system hear the short name NMS (from Network Measuring System).
Engineering performance metrics
NASA Astrophysics Data System (ADS)
Delozier, R.; Snyder, N.
1993-03-01
Implementation of a Total Quality Management (TQM) approach to engineering work required the development of a system of metrics which would serve as a meaningful management tool for evaluating effectiveness in accomplishing project objectives and in achieving improved customer satisfaction. A team effort was chartered with the goal of developing a system of engineering performance metrics which would measure customer satisfaction, quality, cost effectiveness, and timeliness. The approach to developing this system involved normal systems design phases including, conceptual design, detailed design, implementation, and integration. The lessons teamed from this effort will be explored in this paper. These lessons learned may provide a starting point for other large engineering organizations seeking to institute a performance measurement system accomplishing project objectives and in achieving improved customer satisfaction. To facilitate this effort, a team was chartered to assist in the development of the metrics system. This team, consisting of customers and Engineering staff members, was utilized to ensure that the needs and views of the customers were considered in the development of performance measurements. The development of a system of metrics is no different than the development of any type of system. It includes the steps of defining performance measurement requirements, measurement process conceptual design, performance measurement and reporting system detailed design, and system implementation and integration.
Zhu, Kewu; Ng, Wai Kiong; Shen, Shoucang; Tan, Reginald B H; Heng, Paul W S
2008-11-01
To develop a device for simultaneous measurement of particle aerodynamic diameter and electrostatic charge of inhalation aerosols. An integrated system consisting of an add-on charge measurement device and a liquid impinger was developed to simultaneously determine particle aerodynamic diameter and electrostatic charge. The accuracy in charge measurement and fine particle fraction characterization of the new system was evaluated. The integrated system was then applied to analyze the electrostatic charges of a DPI formulation composed of salbutamol sulphate-Inhalac 230 dispersed using a Rotahaler. The charge measurement accuracy was comparable with the Faraday cage method, and incorporation of the charge measurement module had no effect on the performance of the liquid impinger. Salbutamol sulphate carried negative charges while the net charge of Inhalac 230 and un-dispersed salbutamol sulphate was found to be positive after being aerosolized from the inhaler. The instantaneous current signal was strong with small noise to signal ratio, and good reproducibility of charge to mass ratio was obtained for the DPI system investigated. A system for simultaneously measuring particle aerodynamic diameter and aerosol electrostatic charges has been developed, and the system provides a non-intrusive and reliable electrostatic charge characterization method for inhalation dosage forms.
Vandenbroucke, A.; Innes, D.; Lau, F. W. Y.; Hsu, D. F. C.; Reynolds, P. D.; Levin, Craig S.
2015-01-01
Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm3 resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm3 LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image. PMID:25563270
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freese, D. L.; Vandenbroucke, A.; Innes, D.
2015-01-15
Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under constructionmore » consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image.« less
Braithwaite, Jeffrey; Hibbert, Peter; Blakely, Brette; Plumb, Jennifer; Hannaford, Natalie; Long, Janet Cameron; Marks, Danielle
2017-01-01
Objectives: Performance indicators are a popular mechanism for measuring the quality of healthcare to facilitate both quality improvement and systems management. Few studies make comparative assessments of different countries’ performance indicator frameworks. This study identifies and compares frameworks and performance indicators used in selected Organisation for Economic Co-operation and Development health systems to measure and report on the performance of healthcare organisations and local health systems. Countries involved are Australia, Canada, Denmark, England, the Netherlands, New Zealand, Scotland and the United States. Methods: Identification of comparable international indicators and analyses of their characteristics and of their broader national frameworks and contexts were undertaken. Two dimensions of indicators – that they are nationally consistent (used across the country rather than just regionally) and locally relevant (measured and reported publicly at a local level, for example, a health service) – were deemed important. Results: The most commonly used domains in performance frameworks were safety, effectiveness and access. The search found 401 indicators that fulfilled the ‘nationally consistent and locally relevant’ criteria. Of these, 45 indicators are reported in more than one country. Cardiovascular, surgery and mental health were the most frequently reported disease groups. Conclusion: These comparative data inform researchers and policymakers internationally when designing health performance frameworks and indicator sets. PMID:28228948
THE CONCEPT OF A COMMUNITY INFORMATION SYSTEM TO MEASURE THE QUALITY OF PUBLIC SERVICES,
The community information system would consist of the collection of data relevant to public service quality , the periodic reporting of this data in a summarized, sharply focused form, and the application of reliable performance measures to it. The primary purpose of the CIS...groups in forming balanced judgments and making decisions concerning the service they receive. A secondary purpose would be to increase service quality by making it more visible to the public. (Author)
Aerial Radiological Measuring System (ARMS): systems, procedures and sensitivity (1976)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyns, P K
1976-07-01
This report describes the Aerial Radiological Measuring System (ARMS) designed and operated by EG and G, Inc., for the Energy Research and Development Administration's (ERDA) Division of Operational Safety with the cooperation of the Nuclear Regulatory Commission. Designed to rapidly survey large areas for low-level man-made radiation, the ARMS has also proven extremely useful in locating lost radioactive sources of relatively low activity. The system consists of sodium iodide scintillation detectors, data formatting and recording equipment, positioning equipment, meteorological instruments, direct readout hardware, and data analysis equipment. The instrumentation, operational procedures, data reduction techniques and system sensitivities are described, togethermore » with their applications and sample results.« less
A modular, programmable measurement system for physiological and spaceflight applications
NASA Technical Reports Server (NTRS)
Hines, John W.; Ricks, Robert D.; Miles, Christopher J.
1993-01-01
The NASA-Ames Sensors 2000! Program has developed a small, compact, modular, programmable, sensor signal conditioning and measurement system, initially targeted for Life Sciences Spaceflight Programs. The system consists of a twelve-slot, multi-layer, distributed function backplane, a digital microcontroller/memory subsystem, conditioned and isolated power supplies, and six application-specific, physiological signal conditioners. Each signal condition is capable of being programmed for gains, offsets, calibration and operate modes, and, in some cases, selectable outputs and functional modes. Presently, the system has the capability for measuring ECG, EMG, EEG, Temperature, Respiration, Pressure, Force, and Acceleration parameters, in physiological ranges. The measurement system makes heavy use of surface-mount packaging technology, resulting in plug in modules sized 125x55 mm. The complete 12-slot system is contained within a volume of 220x150x70mm. The system's capabilities extend well beyond the specific objectives of NASA programs. Indeed, the potential commercial uses of the technology are virtually limitless. In addition to applications in medical and biomedical sensing, the system might also be used in process control situations, in clinical or research environments, in general instrumentation systems, factory processing, or any other applications where high quality measurements are required.
A modular, programmable measurement system for physiological and spaceflight applications
NASA Astrophysics Data System (ADS)
Hines, John W.; Ricks, Robert D.; Miles, Christopher J.
1993-02-01
The NASA-Ames Sensors 2000] Program has developed a small, compact, modular, programmable, sensor signal conditioning and measurement system, initially targeted for Life Sciences Spaceflight Programs. The system consists of a twelve-slot, multi-layer, distributed function backplane, a digital microcontroller/memory subsystem, conditioned and isolated power supplies, and six application-specific, physiological signal conditioners. Each signal condition is capable of being programmed for gains, offsets, calibration and operate modes, and, in some cases, selectable outputs and functional modes. Presently, the system has the capability for measuring ECG, EMG, EEG, Temperature, Respiration, Pressure, Force, and Acceleration parameters, in physiological ranges. The measurement system makes heavy use of surface-mount packaging technology, resulting in plug in modules sized 125x55 mm. The complete 12-slot system is contained within a volume of 220x150x70mm. The system's capabilities extend well beyond the specific objectives of NASA programs. Indeed, the potential commercial uses of the technology are virtually limitless. In addition to applications in medical and biomedical sensing, the system might also be used in process control situations, in clinical or research environments, in general instrumentation systems, factory processing, or any other applications where high quality measurements are required.
76 FR 16653 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-24
.... (FWIA) is requesting relief from the requirement to provide minimum fuel supply on flight release forms in pounds or gallons. The exemption will enable FWIA to state the minimum fuel supply in the unit of measurement that is consistent with the aircraft fuel system and the company's weight and balance system. [FR...
Brief Report: Development of the Adolescent Empathy and Systemizing Quotients
ERIC Educational Resources Information Center
Auyeung, Bonnie; Allison, Carrie; Wheelwright, Sally; Baron-Cohen, Simon
2012-01-01
Adolescent versions of the Empathy Quotient (EQ) and Systemizing Quotient (SQ) were developed and administered to n = 1,030 parents of typically developing adolescents, aged 12-16 years. Both measures showed good test-retest reliability and high internal consistency. Girls scored significantly higher on the EQ, and boys scored significantly higher…
21 CFR 866.6030 - AFP-L3% immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... system is an in vitro device that consists of reagents and an automated instrument used to quantitatively measure, by immunochemical techniques, AFP and AFP-L3 subfraction in human serum. The device is intended for in vitro diagnostic use as an aid in the risk assessment of patients with chronic liver disease...
A Diagnostic Study of Computer Application of Structural Communication Grid
ERIC Educational Resources Information Center
Bahar, Mehmet; Aydin, Fatih; Karakirik, Erol
2009-01-01
In this article, Structural communication grid (SCG), an alternative measurement and evaluation technique, has been firstly summarised and the design, development and implementation of a computer based SCG system have been introduced. The system is then tested on a sample of 154 participants consisting of candidate students, science teachers and…
The Global Precipitation Measurement (GPM) Spacecraft Power System Design and Orbital Performance
NASA Technical Reports Server (NTRS)
Dakermanji, George; Burns, Michael; Lee, Leonine; Lyons, John; Kim, David; Spitzer, Thomas; Kercheval, Bradford
2016-01-01
The Global Precipitation Measurement (GPM) spacecraft was jointly developed by National Aeronautics and Space Administration (NASA) and Japan Aerospace Exploration Agency (JAXA). It is a Low Earth Orbit (LEO) spacecraft launched on February 27, 2014. The spacecraft is in a circular 400 Km altitude, 65 degrees inclination nadir pointing orbit with a three year basic mission life. The solar array consists of two sun tracking wings with cable wraps. The panels are populated with triple junction cells of nominal 29.5% efficiency. One axis is canted by 52 degrees to provide power to the spacecraft at high beta angles. The power system is a Direct Energy Transfer (DET) system designed to support 1950 Watts orbit average power. The batteries use SONY 18650HC cells and consist of three 8s x 84p batteries operated in parallel as a single battery. The paper describes the power system design details, its performance to date and the lithium ion battery model that was developed for use in the energy balance analysis and is being used to predict the on-orbit health of the battery.
Microprocessor controlled portable TLD system
NASA Technical Reports Server (NTRS)
Apathy, I.; Deme, S.; Feher, I.
1996-01-01
An up-to-date microprocessor controlled thermoluminescence dosemeter (TLD) system for environmental and space dose measurements has been developed. The earlier version of the portable TLD system, Pille, was successfully used on Soviet orbital stations as well as on the US Space Shuttle, and for environmental monitoring. The new portable TLD system, Pille'95, consists of a reader and TL bulb dosemeters, and each dosemeter is provided with an EEPROM chip for automatic identification. The glow curve data are digitised and analysed by the program of the reader. The measured data and the identification number appear on the LED display of the reader. Up to several thousand measured data together with the glow curves can be stored on a removable flash memory card. The whole system is supplied either from built-in rechargeable batteries or from the mains of the space station.
A small, lightweight multipollutant sensor system for ground ...
Characterizing highly dynamic, transient, and vertically lofted emissions from open area sources poses unique measurement challenges. This study developed and applied a multipollutant sensor and integrated sampler system for use on mobile applications including tethered balloons (aerostats) and unmanned aerial vehicles (UAVs). The system is particularly applicable to open area sources, such as forest fires, due to its light weight (3.5 kg), compact size (6.75 L), and internal power supply. The sensor system, termed “Kolibri”, consists of sensors measuring CO2 and CO, and samplers for particulate matter (PM) and volatile organic compounds (VOCs). The Kolibri is controlled by a microcontroller which can record and transfer data in real time through a radio module. Selection of the sensors was based on laboratory testing for accuracy, response delay and recovery, cross-sensitivity, and precision. The Kolibri was compared against rack-mounted continuous emissions monitoring system (CEMs) and another mobile sampling instrument (the “Flyer”) that has been used in over ten open area pollutant sampling events. Our results showed that the time series of CO, CO2, and PM2.5 concentrations measured by the Kolibri agreed well with those from the CEMs and the Flyer, with a laboratory-tested percentage error of 4.9%, 3%, and 5.8%, respectively. The VOC emission factors obtained using the Kolibri were consistent with existing literature values that relate concentration
Smart pillow for heart-rate monitoring using a fiber optic sensor
NASA Astrophysics Data System (ADS)
Chen, Zhihao; Teo, Ju Teng; Ng, Soon Huat; Yim, Huiqing
2011-03-01
In this paper, we propose and demonstrate a new method to monitor heart rate using fiber optic microbending based sensor for in-bed non-intrusive monitoring. The sensing system consists of transmitter, receiver, sensor mat, National Instrument (NI) data acquisition (DAQ) card and a computer for signal processing. The sensor mat is embedded inside a commercial pillow. The heart rate measurement system shows an accuracy of +/-2 beats, which has been successfully demonstrated in a field trial. The key technological advantage of our system is its ability to measure heart rate with no preparation and minimal compliance by the patient.
Initial Results from the Bloomsburg University Goniometer Laboratory
NASA Technical Reports Server (NTRS)
Shepard, M. K.
2002-01-01
The Bloomsburg University Goniometer Laboratory (B.U.G. Lab) consists of three systems for studying the photometric properties of samples. The primary system is an automated goniometer capable of measuring the entire bi-directional reflectance distribution function (BRDF) of samples. Secondary systems include a reflectance spectrometer and digital video camera with macro zoom lens for characterizing and documenting other physical properties of measured samples. Works completed or in progress include the characterization of the BRDF of calibration surfaces for the 2003 Mars Exploration Rovers (MER03), Martian analog soils including JSC-Mars-1, and tests of photometric models.
Pagan, Darren C.; Miller, Matthew P.
2014-01-01
A forward modeling diffraction framework is introduced and employed to identify slip system activity in high-energy diffraction microscopy (HEDM) experiments. In the framework, diffraction simulations are conducted on virtual mosaic crystals with orientation gradients consistent with Nye’s model of heterogeneous single slip. Simulated diffraction peaks are then compared against experimental measurements to identify slip system activity. Simulation results compared against diffraction data measured in situ from a silicon single-crystal specimen plastically deformed under single-slip conditions indicate that slip system activity can be identified during HEDM experiments. PMID:24904242
Contactless Inductive Bubble Detection in a Liquid Metal Flow
Gundrum, Thomas; Büttner, Philipp; Dekdouk, Bachir; Peyton, Anthony; Wondrak, Thomas; Galindo, Vladimir; Eckert, Sven
2016-01-01
The detection of bubbles in liquid metals is important for many technical applications. The opaqueness and the high temperature of liquid metals set high demands on the measurement system. The high electrical conductivity of the liquid metal can be exploited for contactless methods based on electromagnetic induction. We will present a measurement system which consists of one excitation coil and a pickup coil system on the opposite sides of the pipe. With this sensor we were able to detect bubbles in a sodium flow inside a stainless steel pipe and bubbles in a column filled with a liquid Gallium alloy. PMID:26751444
NASA Astrophysics Data System (ADS)
Therssen, E.; Delfosse, L.
1995-08-01
The design and setting up of a pulverized solid injection system for use in laboratory burners is presented. The original dual system consists of a screw feeder coupled to an acoustic sower. This laboratory device allows a good regularity and stability of the particle-gas mixture transported to the burner in a large scale of mass powder and gas vector rate flow. The thermal history of the particles has been followed by optical measurements. The quality of the particle cloud injected in the burner has been validated by the good agreement between experimental and modeling particle temperature.
Pinghung Wei; Raj, Milan; Yung-Yu Hsu; Morey, Briana; DePetrillo, Paolo; McGrane, Bryan; Xianyan Wang; Lin, Monica; Keen, Bryan; Papakyrikos, Cole; Lowe, Jared; Ghaffari, Roozbeh
2014-01-01
In this paper, we present a stretchable wearable system capable of i) measuring multiple physiological parameters and ii) transmitting data via radio frequency to a smart phone. The electrical architecture consists of ultra thin sensors (<; 20 μm thick) and a conformal network of associated active and passive electronics in a mesh-like geometry that can mechanically couple with the curvilinear surfaces of the human body. Spring-like metal interconnects between individual chips on board the device allow the system to accommodate strains approaching ~30% A representative example of a smart patch that measures movement and electromyography (EMG) signals highlights the utility of this new class of medical skin-mounted system in monitoring a broad range of neuromuscular and cardiovascular diseases.
A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michnoff R.; Biscardi, C.; Cerniglia, P.
2012-04-15
A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scannermore » assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.« less
Measuring the impact of final demand on global production system based on Markov process
NASA Astrophysics Data System (ADS)
Xing, Lizhi; Guan, Jun; Wu, Shan
2018-07-01
Input-output table is a comprehensive and detailed in describing the national economic systems, consisting of supply and demand information among various industrial sectors. The complex network, a theory and method for measuring the structure of complex system, can depict the structural properties of social and economic systems, and reveal the complicated relationships between the inner hierarchies and the external macroeconomic functions. This paper tried to measure the globalization degree of industrial sectors on the global value chain. Firstly, it constructed inter-country input-output network models to reproduce the topological structure of global economic system. Secondly, it regarded the propagation of intermediate goods on the global value chain as Markov process and introduced counting first passage betweenness to quantify the added processing amount when globally final demand stimulates this production system. Thirdly, it analyzed the features of globalization at both global and country-sector level
A New PC and LabVIEW Package Based System for Electrochemical Investigations
Stević, Zoran; Andjelković, Zoran; Antić, Dejan
2008-01-01
The paper describes a new PC and LabVIEW software package based system for electrochemical research. An overview of well known electrochemical methods, such as potential measurements, galvanostatic and potentiostatic method, cyclic voltammetry and EIS is given. Electrochemical impedance spectroscopy has been adapted for systems containing large capacitances. For signal generation and recording of the response of investigated electrochemical cell, a measurement and control system was developed, based on a PC P4. The rest of the hardware consists of a commercially available AD-DA converter and an external interface for analog signal processing. The interface is a result of authors own research. The software platform for desired measurement methods is LabVIEW 8.2 package, which is regarded as a high standard in the area of modern virtual instruments. The developed system was adjusted, tested and compared with commercially available system and ORCAD simulation. PMID:27879794
A motion detection system for AXAF X-ray ground testing
NASA Technical Reports Server (NTRS)
Arenberg, Jonathan W.; Texter, Scott C.
1993-01-01
The concept, implementation, and performance of the motion detection system (MDS) designed as a diagnostic for X-ray ground testing for AXAF are described. The purpose of the MDS is to measure the magnitude of a relative rigid body motion among the AXAF test optic, the X-ray source, and X-ray focal plane detector. The MDS consists of a point source, lens, centroid detector, transimpedance amplifier, and computer system. Measurement of the centroid position of the image of the optical point source provides a direct measure of the motions of the X-ray optical system. The outputs from the detector and filter/amplifier are digitized and processed using the calibration with a 50 Hz bandwidth to give the centroid's location on the detector. Resolution of 0.008 arcsec has been achieved by this system. Data illustrating the performance of the motion detection system are also presented.
Calibration Method of an Ultrasonic System for Temperature Measurement
Zhou, Chao; Wang, Yueke; Qiao, Chunjie; Dai, Weihua
2016-01-01
System calibration is fundamental to the overall accuracy of the ultrasonic temperature measurement, and it is basically involved in accurately measuring the path length and the system latency of the ultrasonic system. This paper proposes a method of high accuracy system calibration. By estimating the time delay between the transmitted signal and the received signal at several different temperatures, the calibration equations are constructed, and the calibrated results are determined with the use of the least squares algorithm. The formulas are deduced for calculating the calibration uncertainties, and the possible influential factors are analyzed. The experimental results in distilled water show that the calibrated path length and system latency can achieve uncertainties of 0.058 mm and 0.038 μs, respectively, and the temperature accuracy is significantly improved by using the calibrated results. The temperature error remains within ±0.04°C consistently, and the percentage error is less than 0.15%. PMID:27788252
Electrical conductivity of metal powders under pressure
NASA Astrophysics Data System (ADS)
Montes, J. M.; Cuevas, F. G.; Cintas, J.; Urban, P.
2011-12-01
A model for calculating the electrical conductivity of a compressed powder mass consisting of oxide-coated metal particles has been derived. A theoretical tool previously developed by the authors, the so-called `equivalent simple cubic system', was used in the model deduction. This tool is based on relating the actual powder system to an equivalent one consisting of deforming spheres packed in a simple cubic lattice, which is much easier to examine. The proposed model relates the effective electrical conductivity of the powder mass under compression to its level of porosity. Other physically measurable parameters in the model are the conductivities of the metal and oxide constituting the powder particles, their radii, the mean thickness of the oxide layer and the tap porosity of the powder. Two additional parameters controlling the effect of the descaling of the particle oxide layer were empirically introduced. The proposed model was experimentally verified by measurements of the electrical conductivity of aluminium, bronze, iron, nickel and titanium powders under pressure. The consistency between theoretical predictions and experimental results was reasonably good in all cases.
Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U
2018-06-01
Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.
New Constraints on the Abundance of 60Fe in the Early Solar System
NASA Astrophysics Data System (ADS)
Trappitsch, Reto; Boehnke, Patrick; Stephan, Thomas; Telus, Myriam; Savina, Michael R.; Pardo, Olivia; Davis, Andrew M.; Dauphas, Nicolas; Pellin, Michael J.; Huss, Gary R.
2018-04-01
Establishing the abundance of the extinct radionuclide 60Fe (half-life 2.62 Ma) in the early solar system is important for understanding the astrophysical context of solar system formation. While bulk measurements of early solar system phases show a low abundance consistent with galactic background, some in situ measurements by secondary ion mass spectrometry (SIMS) imply a higher abundance, which would require injection from a nearby supernova (SN). Here we present in situ nickel isotopic analyses by resonance ionization mass spectrometry (RIMS) in a chondrule from the primitive meteorite Semarkona (LL3.00). The same chondrule had been previously analyzed by SIMS. Despite improved precision compared to SIMS, the RIMS nickel isotopic data do not reveal any resolved excesses of 60Ni that could be unambiguously ascribed to in situ 60Fe decay. Linear regression of 60Ni/58Ni versus 56Fe/58Ni yields an initial 60Fe/56Fe ratio for this chondrule of (3.8 ± 6.9) × 10‑8, which is consistent with both the low initial value found by bulk measurements and the low end of the range of initial ratios inferred from some in situ work. The same regression also gives a solar initial 60Ni/58Ni ratio, which shows that this sample was not disturbed by nickel mobilization, thus agreeing with a low initial 60Fe/56Fe ratio. These findings agree with a re-evaluation of previous SIMS measurements of the same sample. Supernova injection of 60Fe into the solar system or its parental cloud material is therefore not necessary to account for the measured solar system’s initial amount of 60Fe.
Measurement device for high-precision spectral transmittance of solar blind filter
NASA Astrophysics Data System (ADS)
Wang, Yan; Qian, Yunsheng; Lv, Yang; Feng, Cheng; Liu, Jian
2017-02-01
In order to measure spectral transmittance of solar-blind filter ranging from ultraviolet to visible light accurately, a high-precision filter transmittance measuring system based on the ultraviolet photomultiplier is developed. The calibration method is mainly used to measure transmittance in this system, which mainly consists of an ultraviolet photomultiplier as core of the system and a lock-in amplifier combined with an optical modulator as the aided measurement for the system. The ultraviolet photomultiplier can amplify the current signal through the filter and have the characteristics of low dark current and high luminance gain. The optical modulator and the lock-in amplifier can obtain the signal from the photomultiplier and inhibit dark noise and spurious signal effectively. Through these two parts, the low light passing through the filters can be detected and we can calculate the transmittance by the optical power detected. Based on the proposed system, the limit detection of the transmittance can reach 10-12, while the result of the conventional approach is merely 10-6. Therefore, the system can make an effective assessment of solar blind ultraviolet filters.
Smart measurement system for resistive (bridge) or capacitive sensors
NASA Astrophysics Data System (ADS)
Wang, Guijie; Meijer, Gerard C. M.
1998-07-01
A low-cost smart measurement system for resistive (bridge) and capacitive sensors is presented and demonstrated. The measurement system consists of three main parts: the sensor element, a universal transducer interface (UTI) and a microcontroller. The UTI is a sensor-signal-to-time converter, based on a period-modulated oscillator, which is equipped with front-ends for many types of resistive (bridge) and capacitive sensors, and which generates a microcontroller-compatible output signal. The microcontroller performs data acquisition of the output signals from the interface UTI, controls the working status of the UTI for a specified application and communicates with a personal computer. Continuous auto-calibration of the offset and the gain of the complete system is applied to eliminate many nonidealities. Experimental results show that the accuracy and resolution are 14 bits and 16 bits, respectively, for a measurement time of about 100 ms.
Lightweight mid-infrared methane sensor for unmanned aerial systems
NASA Astrophysics Data System (ADS)
Golston, Levi M.; Tao, Lei; Brosy, Caroline; Schäfer, Klaus; Wolf, Benjamin; McSpiritt, James; Buchholz, Bernhard; Caulton, Dana R.; Pan, Da; Zondlo, Mark A.; Yoel, David; Kunstmann, Harald; McGregor, Marty
2017-06-01
The design and field performance of a compact diode laser-based instrument for measuring methane on unmanned aerial systems (UAS) is described. The system is based on open-path, wavelength modulation spectroscopy with a 3.27 µm GaSb laser. We design two versions of the sensor for a long-endurance fixed wing UAS and a rotary wing hexacopter, with instrument masses of 4.6 and 1.6 kg, respectively. The long-endurance platform was used to measure vertical profiles of methane up to 600 m in altitude and showed repeatability of 13 ppbv between multiple profiles. Additionally, the hexacopter system was used to evaluate the evolution of methane in the nocturnal boundary layer during the ScaleX field campaign in Germany, where measured data is consistent with supporting ground-based methane and meteorological measurements. Testing results on both platforms demonstrated our lightweight methane sensor had an in-flight precision of 5-10 ppbv Hz-1/2.
Lai, WeiJen; Midorikawa, Yoshiyuki; Kanno, Zuisei; Takemura, Hiroshi; Suga, Kazuhiro; Soga, Kohei; Ono, Takashi; Uo, Motohiro
2016-12-01
We developed a device to evaluate the orthodontic force applied by systems requiring high operability. A life-sized, two-tooth model was designed, and the measurements were performed using a custom-made jointed attachment, referred to as an "action stick", to allow clearance for the oversized six-axis sensors. This tooth-sensor apparatus was accurately calibrated, and the error was limited. Vector analysis and rotating coordinate transformation were required to derive the force and moment at the tooth from the sensor readings. The device was then used to obtain measurements of the force and moment generated by the V-bend system. Our device was effective, providing results that were consistent with those of previous studies. This measurement device can be manufactured with force sensors of any size, and it can also be expanded to models with any number of teeth.
Kang, X; Wang, H; Wang, Y; Harvey, L M; McNeil, B
2001-10-01
The filamentous fungus, Sclerotium glucanicum NRRL 3006, was cultivated in a 0.008 m(3) airlift bioreactor with internal recirculation loop (ARL-IL) for production of the biopolymer, scleroglucan. The rheological behaviour of the culture fluid was characterised by measurement of the fluid consistency coefficient (K) and the flow behaviour index (n). Based on these measurements, the culture fluid changed from a low viscosity Newtonian system early in the process, to a viscous non-Newtonian (pseudoplastic) system. In addition, reactor hydrodynamics and mixing behaviour were characterised by measurement of whole mean gas hold-up (epsilon(g)), liquid re-circulation velocity (U(ld)) and mixing time (t(m)). Under identical process conditions, the effects of the viscosity of the culture fluid and air flow rate on epsilon(g), U(ld) and t(m) were examined and empirical correlations for epsilon(g), U(ld) and t(m) with both superficial velocity U(g) and consistency coefficient K were obtained and expressed separately. The correlations obtained are likely to describe the behaviour of real fungal culture fluids more accurately than previous correlations based on Newtonian or simulated non-Newtonian systems.
Compositional Constraints on the Best Characterized Rocky Exoplanet, Kepler-36 b
NASA Astrophysics Data System (ADS)
Rogers, Leslie; Deck, Katherine; Lissauer, Jack J.; Carter, Joshua A.
2015-01-01
Kepler-36 is an extreme planetary system, consisting of two transiting sub-Neptune-size planets that revolve around a sub-giant star with orbital periods of 13.84 and 16.24 days. Mutual gravitational interactions between the two planets perturb the planets' transit times, allowing the planets' masses to be measured. Despite the similarity of their masses and orbital radii, the planets show a stark contrast in their mean densities; the inner planet (Kepler-36 b) is more than eight times as dense as its outer companion planet (Kepler-36 c). We perform a photo-dynamical analysis of the Kepler-36 system based on more than three years of Kepler photometry. With N-body integrations of initial conditions sampled from the photo-dynamical fits, we further refine the properties of the system by ruling out solutions that show large-scale instability within 5 Giga-days. Ultimately, we measure the planets' masses within 4.2% precision, and the planets' radii with 1.8% precision. Kepler-36 b is currently the rocky exoplanet with the most precisely measured mass and radius. Kepler-36 b's mass and radius are consistent with an Earth-like composition, and an iron-enhanced Mercury-like composition is ruled out.
Compositional Constraints on the Best Characterized Rocky Exoplanet, Kepler-36 b
NASA Astrophysics Data System (ADS)
Rogers, Leslie Anne; Deck, Katherine; Lissauer, Jack; Carter, Joshua
2015-08-01
Kepler-36 is an extreme planetary system, consisting of two transiting sub-Neptune-size planets that revolve around a sub-giant star with orbital periods of 13.84 and 16.24 days. Mutual gravitational interactions between the two planets perturb the planets' transit times, allowing the planets' masses to be measured. Despite the similarity of their masses and orbital radii, the planets show a stark contrast in their mean densities; the inner planet (Kepler-36 b) is more than eight times as dense as its outer companion planet (Kepler-36 c). We perform a photo-dynamical analysis of the Kepler-36 system based on more than three years of Kepler photometry. With N-body integrations of initial conditions sampled from the photo-dynamical fits, we further refine the properties of the system by ruling out solutions that show large scale instability within 5 Giga-days. Ultimately, we measure the planets' masses within 4.2% precision, and the planets' radii with 1.8% precision. Kepler-36 b is currently the rocky exoplanet with the most precisely measured mass and radius. Kepler-36 b’s mass and radius are consistent with a Earth-like composition, and an iron-enhanced Mercury-like composition is ruled out.
Compositional Constraints on the Best Characterized Rocky Exoplanet, Kepler-36 b
NASA Astrophysics Data System (ADS)
Rogers, L.; Deck, K.; Lissauer, J. J.; Carter, J.
2014-12-01
Kepler-36 is an extreme planetary system, consisting of two transiting sub-Neptune-size planets that revolve around a sub-giant star with orbital periods of 13.84 and 16.24 days. Mutual gravitational interactions between the two planets perturb the planets' transit times, allowing the planets' masses to be measured. Despite the similarity of their masses and orbital radii, the planets show a stark contrast in their mean densities; the inner planet (Kepler-36 b) is more than eight times as dense as its outer companion planet (Kepler-36 c). We perform a photo-dynamical analysis of the Kepler-36 system based on more than three years of Kepler photometry. With N-body integrations of initial conditions sampled from the photo-dynamical fits, we further refine the properties of the system by ruling out solutions that show large scale instability within 5 Giga-days. Ultimately, we measure the planets' masses within 4.2% precision, and the planets' radii with 1.8% precision. Kepler-36 b is currently the rocky exoplanet with the most precisely measured mass and radius. Kepler-36 b's mass and radius are consistent with a Earth-like composition, and an iron-enhanced Mercury-like composition is ruled out.
Iyengar, Anagha; Beach, Matthew; Newby, Robert J.; ...
2015-11-12
Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reductionmore » in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.« less
NASA Astrophysics Data System (ADS)
Santos, T. Q.; Alvarenga, A. V.; Oliveira, D. P.; Mayworm, R. C.; Souza, R. M.; Costa-Félix, R. P. B.
2016-07-01
Speed of sound is an important quantity to characterize reference materials for ultrasonic applications, for instance. The alignment between the transducer and the test body is an key activity in order to perform reliable and consistent measurement. The aim of this work is to evaluate the influence of the alignment system to the expanded uncertainty of such measurement. A stainless steel cylinder was previously calibrated on an out of water system typically used for calibration of non-destructive blocks. Afterwards, the cylinder was calibrated underwater with two distinct alignment system: fixed and mobile. The values were statistically compared to the out-of-water measurement, considered the golden standard for such application. For both alignment systems, the normalized error was less than 0.8, leading to conclude that the both measurement system (under and out-of-water) do not diverge significantly. The gold standard uncertainty was 2.7 m-s-1, whilst the fixed underwater system resulted in 13 m-s-1, and the mobile alignment system achieved 6.6 m-s-1. After the validation of the underwater system for speed of sound measurement, it will be applied to certify Encapsulated Tissue Mimicking Material as a reference material for biotechnology application.
Heat pump processes induced by laser radiation
NASA Technical Reports Server (NTRS)
Garbuny, M.; Henningsen, T.
1980-01-01
A carbon dioxide laser system was constructed for the demonstration of heat pump processes induced by laser radiation. The system consisted of a frequency doubling stage, a gas reaction cell with its vacuum and high purity gas supply system, and provisions to measure the temperature changes by pressure, or alternatively, by density changes. The theoretical considerations for the choice of designs and components are dicussed.
The Design of Optical Sensor for the Pinhole/Occulter Facility
NASA Technical Reports Server (NTRS)
Greene, Michael E.
1990-01-01
Three optical sight sensor systems were designed, built and tested. Two optical lines of sight sensor system are capable of measuring the absolute pointing angle to the sun. The system is for use with the Pinhole/Occulter Facility (P/OF), a solar hard x ray experiment to be flown from Space Shuttle or Space Station. The sensor consists of a pinhole camera with two pairs of perpendicularly mounted linear photodiode arrays to detect the intensity distribution of the solar image produced by the pinhole, track and hold circuitry for data reduction, an analog to digital converter, and a microcomputer. The deflection of the image center is calculated from these data using an approximation for the solar image. A second system consists of a pinhole camera with a pair of perpendicularly mounted linear photodiode arrays, amplification circuitry, threshold detection circuitry, and a microcomputer board. The deflection of the image is calculated by knowing the position of each pixel of the photodiode array and merely counting the pixel numbers until threshold is surpassed. A third optical sensor system is capable of measuring the internal vibration of the P/OF between the mask and base. The system consists of a white light source, a mirror and a pair of perpendicularly mounted linear photodiode arrays to detect the intensity distribution of the solar image produced by the mirror, amplification circuitry, threshold detection circuitry, and a microcomputer board. The deflection of the image and hence the vibration of the structure is calculated by knowing the position of each pixel of the photodiode array and merely counting the pixel numbers until threshold is surpassed.
Pulsed Electric Propulsion Thrust Stand Calibration Method
NASA Technical Reports Server (NTRS)
Wong, Andrea R.; Polzin, Kurt A.; Pearson, J. Boise
2011-01-01
The evaluation of the performance of any propulsion device requires the accurate measurement of thrust. While chemical rocket thrust is typically measured using a load cell, the low thrust levels associated with electric propulsion (EP) systems necessitate the use of much more sensitive measurement techniques. The design and development of electric propulsion thrust stands that employ a conventional hanging pendulum arm connected to a balance mechanism consisting of a secondary arm and variable linkage have been reported in recent publications by Polzin et al. These works focused on performing steady-state thrust measurements and employed a static analysis of the thrust stand response. In the present work, we present a calibration method and data that will permit pulsed thrust measurements using the Variable Amplitude Hanging Pendulum with Extended Range (VAHPER) thrust stand. Pulsed thrust measurements are challenging in general because the pulsed thrust (impulse bit) occurs over a short timescale (typically 1 micros to 1 millisecond) and cannot be resolved directly. Consequently, the imparted impulse bit must be inferred through observation of the change in thrust stand motion effected by the pulse. Pulsed thrust measurements have typically only consisted of single-shot operation. In the present work, we discuss repetition-rate pulsed thruster operation and describe a method to perform these measurements. The thrust stand response can be modeled as a spring-mass-damper system with a repetitive delta forcing function to represent the impulsive action of the thruster.
NCSP IER 422 CED-3b Documentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchinson, Jesson D.; Cutler, Theresa Elizabeth; Bahran, Rian Mustafa
2017-11-22
A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment has been designed and measured. In this experiment, multiplication is approximated using correlated neutron data from a detector system consisting of 3He tubes inside high density polyethylene (HDPE). Measurements were performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations were performed with the plutonium ball nested in various thicknesses of interleaved HDPE spherical shells mixed in with the Cu shells. The HDPE is intended to provide fast neutron moderation and reflection,more » resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity.« less
Wei, Wenhui; Gao, Zhaohui; Gao, Shesheng; Jia, Ke
2018-04-09
In order to meet the requirements of autonomy and reliability for the navigation system, combined with the method of measuring speed by using the spectral redshift information of the natural celestial bodies, a new scheme, consisting of Strapdown Inertial Navigation System (SINS)/Spectral Redshift (SRS)/Geomagnetic Navigation System (GNS), is designed for autonomous integrated navigation systems. The principle of this SINS/SRS/GNS autonomous integrated navigation system is explored, and the corresponding mathematical model is established. Furthermore, a robust adaptive central difference particle filtering algorithm is proposed for this autonomous integrated navigation system. The simulation experiments are conducted and the results show that the designed SINS/SRS/GNS autonomous integrated navigation system possesses good autonomy, strong robustness and high reliability, thus providing a new solution for autonomous navigation technology.
`Counterfactual' interpretation of the quantum measurement process
NASA Astrophysics Data System (ADS)
Nisticò, Giuseppe
1997-08-01
The question of the determination of the state of the system during a measurement experiment is discussed within quantum theory, as a part of the more general measurement’s problem. I propose a counterfactual interpretation of the measurement process which answers the question from a conceptual point of view. This interpretation turns out to be consistent with the predictions of quantum theory, but it presents difficulties from an operational point of view.
Performance of the Defense Acquisition System, 2015 Annual report
2015-09-16
Planned Total (From Start to Completion) Quantity-Adjusted Unit -Procurement Recurring-Flyaway Funding (1999–2014) NOTE: This measures biennial...PAUC is a different funding measure define by statute (10 United States Code [U.S.C.], sections 2430a and 2432) consisting of the total acquisition... measures that (unlike PAUC and APUC) are fully adjusted for any changes in procurement quantity. These results help compare procurement unit costs
Multichannel System Based on a High Sensitivity Superconductive Sensor for Magnetoencephalography
Rombetto, Sara; Granata, Carmine; Vettoliere, Antonio; Russo, Maurizio
2014-01-01
We developed a multichannel system based on superconducting quantum interference devices (SQUIDs) for magnetoencephalography measurements. Our system consists of 163 fully-integrated SQUID magnetometers, 154 channels and 9 references, and all of the operations are performed inside a magnetically-shielded room. The system exhibits a magnetic field noise spectral density of approximatively 5 fT/Hz1/2. The presented magnetoencephalography is the first system working in a clinical environment in Italy. PMID:25006995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Y.; Frank, J.R.; St. Martin, E.J.
Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. The authors have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of themore » trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean-square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA monitoring system when a corrosion inhibitor was added into one of the test loops during the corrosion testing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Y. J.
Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trendmore » of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA monitoring system when a corrosion inhibitor was added into one of the test loops during the corrosion testing.« less
Measurements of vector fields with diode array
NASA Technical Reports Server (NTRS)
Wiehr, E. J.; Scholiers, W.
1985-01-01
A polarimeter was designed for high spatial and spectral resolution. It consists of a quarter-wave plate alternately operating in two positions for Stoke-V measurements and an additional quarter-wave plate for Stokes-U and -Q measurements. The spatial range covers 75 arcsec, the spectral window of about 1.8 a allows the simultaneous observations of neighboring lines. The block diagram of the data processing and acquisition system consists of five memories each one having a capacity of 10 to the 4th power 16-bit words. The total time to acquire profiles of Stokes parameters can be chosen by selecting the number of successive measurements added in the memories, each individual measurement corresponding to an integration time of 0.5 sec. Typical values range between 2 and 60 sec depending on the brightness of the structure, the amount of polarization and a compromise between desired signal-to-noise ratio and spatial resolution.
Active laser radar (lidar) for measurement of corresponding height and reflectance images
NASA Astrophysics Data System (ADS)
Froehlich, Christoph; Mettenleiter, M.; Haertl, F.
1997-08-01
For the survey and inspection of environmental objects, a non-tactile, robust and precise imaging of height and depth is the basis sensor technology. For visual inspection,surface classification, and documentation purposes, however, additional information concerning reflectance of measured objects is necessary. High-speed acquisition of both geometric and visual information is achieved by means of an active laser radar, supporting consistent 3D height and 2D reflectance images. The laser radar is an optical-wavelength system, and is comparable to devices built by ERIM, Odetics, and Perceptron, measuring the range between sensor and target surfaces as well as the reflectance of the target surface, which corresponds to the magnitude of the back scattered laser energy. In contrast to these range sensing devices, the laser radar under consideration is designed for high speed and precise operation in both indoor and outdoor environments, emitting a minimum of near-IR laser energy. It integrates a laser range measurement system and a mechanical deflection system for 3D environmental measurements. This paper reports on design details of the laser radar for surface inspection tasks. It outlines the performance requirements and introduces the measurement principle. The hardware design, including the main modules, such as the laser head, the high frequency unit, the laser beam deflection system, and the digital signal processing unit are discussed.the signal processing unit consists of dedicated signal processors for real-time sensor data preprocessing as well as a sensor computer for high-level image analysis and feature extraction. The paper focuses on performance data of the system, including noise, drift over time, precision, and accuracy with measurements. It discuses the influences of ambient light, surface material of the target, and ambient temperature for range accuracy and range precision. Furthermore, experimental results from inspection of buildings, monuments and industrial environments are presented. The paper concludes by summarizing results achieved in industrial environments and gives a short outlook to future work.
Investigating potential wet bias in the Purple Crow Lidar water vapor measurements
NASA Astrophysics Data System (ADS)
VanKerkhove, Jeffrey; Sica, R. J.; Wing, R.; Argall, P. S.
2018-04-01
The Purple Crow Lidar is a large aperture lidar, capable of retrieving water vapor into the strato-sphere. A comparison with the ALVICE lidar in 2012 showed water vapor measurements were consistently larger than those of ALVICE in the lower stratosphere, prompting an investigation of the system. Processing approaches and additional instrumental corrections are considered.
Measurement-based management of mental health quality and access in VHA: SAIL mental health domain.
Lemke, Sonne; Boden, Matthew Tyler; Kearney, Lisa K; Krahn, Dean D; Neuman, Matthew J; Schmidt, Eric M; Trafton, Jodie A
2017-02-01
We outline the development of a Mental Health Domain to track accessibility and quality of mental health care in the United States Veterans Health Administration (VHA) as part of a broad-based performance measurement system. This domain adds an important element to national performance improvement efforts by targeting regional and facility leadership and providing them a concise yet comprehensive measure to identify facilities facing challenges in their mental health programs. We present the conceptual framework and rationale behind measure selection and development. The Mental Health Domain covers three important aspects of mental health treatment: Population Coverage, Continuity of Care, and Experience of Care. Each component is a composite of existing and newly adapted measures with moderate to high internal consistency; components are statistically independent or moderately related. Development and dissemination of the Mental Health Domain involved a variety of approaches and benefited from close collaboration between local, regional, and national leadership and from coordination with existing quality-improvement initiatives. During the first year of use, facilities varied in the direction and extent of change. These patterns of change were generally consistent with qualitative information, providing support for the validity of the domain and its component measures. Measure maintenance remains an iterative process as the VHA mental health system and potential data resources continue to evolve. Lessons learned may be helpful to the broader mental health-provider community as mental health care consolidates and becomes increasingly integrated within healthcare systems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Applications of optical coherence tomography in the non-contact assessment of automotive paints
NASA Astrophysics Data System (ADS)
Lawman, Samuel; Zhang, Jinke; Williams, Bryan M.; Zheng, Yalin; Shen, Yao-Chun
2017-06-01
The multiple layer paint systems on modern cars serve two end purposes, they firstly protect against corrosion and secondly give the desired visual appearance. To ensure consistent corrosion protection and appearance, suitable Quality Assurance (QA) measures on the final product are required. Various (layer thickness and consistency, layer composition, flake statistics, surface profile and layer dryness) parameters are of importance, each with specific techniques that can measure one or some of them but no technique that can measure all or most of them. Optical Coherence Tomography (OCT) is a 3D imaging technique with micrometre resolution. Since 2016, OCT measurements of layer thickness and consistency, layer composition fingerprint and flake statistics have been reported. In this paper we demonstrate two more novel applications of OCT to automotive paints. Firstly, we use OCT to quantify unwanted surface texture, which leads to an "orange peel" visual defect. This was done by measuring the surface profiles of automotive paints, with an unoptimised precision of 37 nm over lateral range of 7 mm, to quantify texture of less than 500 nm. Secondly, we demonstrate that OCT can measure how dry a coating layer is by measuring how fast it is still shrinking quasiinstantaneously, using Fourier phase sensitivity.
Surface Composition Influence on Internal Gas Flow at Large Knudsen Numbers
2000-07-09
situated in an ultra high vacuum system . The system is supplied with means of gas phase, surface CP585, Rarefied Gas Dynamics: 22nd International...control and gas flow measuring system . The experimental procedure consists in a few stages. The first stage includes surface preparation process at...solid body system , Proceedings 20-th Int. Symp. Rarefied Gas Dynamics, Peking University Press, Beijing, China, 1997, pp. 387-391. 3. Lord, R.G
Consistency of nuclear thermometric measurements at moderate excitation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rana, T. K.; Bhattacharya, C.; Kundu, S.
2008-08-15
A comparison of various thermometric techniques used for the estimation of nuclear temperature has been made from the decay of hot composite {sup 32}S* produced in the reaction {sup 20}Ne (145 MeV) + {sup 12}C. It is shown that the temperatures estimated by different techniques, known to vary significantly in the Fermi energy domain, are consistent with each other within experimental limits for the system studied here.
Kyi, M; Wraight, P R; Rowan, L M; Marley, K A; Colman, P G; Fourlanos, S
2018-06-01
To investigate the effect of a novel glucose alert system, comprising the Melbourne Glucose Alert Pathway and glucose-alert-capable networked blood glucose meters, on nursing and hospital medical officer responses to adverse glycaemia. A prospective, pre- and post-observational study was undertaken in non-critical care wards of a tertiary hospital over 4 months (n=148 or 660 patient-days). The intervention consisted of two components designed to promote a consistent staff response to blood glucose measurements: (1) a clinical escalation pathway, the Melbourne Glucose Alert Pathway, and (2) networked blood glucose meters, which provide a visual alert for out-of-range blood glucose measurement. All consecutive inpatients with diabetes were assessed for diabetes management and capillary blood glucose. The primary outcome was documented nursing and medical staff action in response to episodes of adverse glycaemia (blood glucose >15 mmol/l or <4 mmol/l). Secondary outcomes consisted of glycaemic measures. In response to episodes of adverse glycaemia, nursing action increased (proportion with nursing action: 45% to 73%; P<0.001), and medical action increased (proportion with medical action: 49% to 67%; P=0.011) with the glucose alert system in place. Patient-days with hyperglycaemia (any blood glucose value >15 mmol/l: 24% vs 16%; P=0.012) and patient-days with mean blood glucose >15 mmol/l (7.4% vs 2.6%; P=0.005) decreased. There was no difference in hypoglycaemia incidence. Use of a novel glucose alert system improved health professional responses to adverse glycaemia and decreased hyperglycaemia in the hospital setting. © 2018 Diabetes UK.
Measuring Sirius: An Exercise in Patience
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2017-05-01
Sometimes important astronomical advances require the newest and fanciest observatories and technologies but sometimes they just require decades of work and a lot of patience. Patience is finally paying off for a team of scientists who have been observing the Sirius star system for nearly 20 years.Historical (black, blue and green) and Hubble (red) observations of the relative orbit of Sirius B around Sirius A. [Adapted from Bond et al. 2017]Bright NeighborsLocated a mere 8.5 light-years away, the Sirius system consists of the main-sequence star Sirius A and its white-dwarf companion Sirius B. Sirius A is the brightest star in our sky, and Sirius B is the brightest and nearest white dwarf weve observed. The unusual proximity and brightness of these stars make them excellent targets for learning about stellar and white-dwarf astrophysics.In order to interpret our observations, however, we first need to pin down the basic information about these stars. In particular, we want to measure the precise masses and orbital elements for the system but because the stars orbit each other only once every 50 years, these properties take time to measure well!Toward this end, a team of scientists began an observing campaign in 2001 to regularly image the Sirius system using the Hubble Space Telescope. Now, 16 years later, they have enough data to make precise statements about the system.Precision Measurements at LastIn a recent publication led by Howard Bond (Pennsylvania State University and Space Telescope Science Institute), the team details nearly two decades of precise photometric and astrometric measurements using Hubble. In addition, they supplemented these data by dredging through 150 years worth of historical observations of Sirius and critically analyzing 2,300 of these as well.Comparisons of white-dwarf theory with the observed parameters of Sirius B, both on the H-R diagram (top) and in a mass-radius plot of cooling white dwarfs (bottom). Sirius Bs measured parameters matches the theoretical models very well. [Bond et al. 2017]The result? Bond and collaborators were able to make very precise measurements of the masses of Sirius A and Sirius B 2.063 0.023 and 1.018 0.011 solar masses, respectively and of their orbital elements. They find that the position of Sirius B on the Hertzsprung-Russell diagram is beautifully consistent with models based on cooling white dwarfs of Sirius Bs measured mass. Similarly, stellar models of Sirius A are nicely consistent with Bond and collaborators measurements if the star has a slightly low metallicity of 85% that of the Sun.The high-precision measurements also allowed the authors rule out the possibility of a third body in the system an idea thats been tossed around for decades unless the third body is smaller than 1525 Jupiter masses.Bond and collaborators enumerate some open puzzles of the Sirius system, such as like conflicting signs that the two stars might have interacted, long ago. Though these puzzles remain unresolved, the painstaking decades of observations of Sirius have already revealed much about the system and improved our understanding of stellar evolution. Whats more, these measurements give us an ideal launching point for future studies of these two objects. In the case of the Sirius system, patience has definitely paid off.CitationHoward E. Bond et al 2017 ApJ 840 70. doi:10.3847/1538-4357/aa6af8
High-precision real-time 3D shape measurement based on a quad-camera system
NASA Astrophysics Data System (ADS)
Tao, Tianyang; Chen, Qian; Feng, Shijie; Hu, Yan; Zhang, Minliang; Zuo, Chao
2018-01-01
Phase-shifting profilometry (PSP) based 3D shape measurement is well established in various applications due to its high accuracy, simple implementation, and robustness to environmental illumination and surface texture. In PSP, higher depth resolution generally requires higher fringe density of projected patterns which, in turn, lead to severe phase ambiguities that must be solved with additional information from phase coding and/or geometric constraints. However, in order to guarantee the reliability of phase unwrapping, available techniques are usually accompanied by increased number of patterns, reduced amplitude of fringe, and complicated post-processing algorithms. In this work, we demonstrate that by using a quad-camera multi-view fringe projection system and carefully arranging the relative spatial positions between the cameras and the projector, it becomes possible to completely eliminate the phase ambiguities in conventional three-step PSP patterns with high-fringe-density without projecting any additional patterns or embedding any auxiliary signals. Benefiting from the position-optimized quad-camera system, stereo phase unwrapping can be efficiently and reliably performed by flexible phase consistency checks. Besides, redundant information of multiple phase consistency checks is fully used through a weighted phase difference scheme to further enhance the reliability of phase unwrapping. This paper explains the 3D measurement principle and the basic design of quad-camera system, and finally demonstrates that in a large measurement volume of 200 mm × 200 mm × 400 mm, the resultant dynamic 3D sensing system can realize real-time 3D reconstruction at 60 frames per second with a depth precision of 50 μm.
A Non-Contact Measurement System for the Range of Motion of the Hand
Pham, Trieu; Pathirana, Pubudu N.; Trinh, Hieu; Fay, Pearse
2015-01-01
An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers. PMID:26225976
Autonomic Nervous System Responses to Hearing-Related Demand and Evaluative Threat.
Mackersie, Carol L; Kearney, Lucia
2017-10-12
This paper consists of 2 parts. The purpose of Part 1 was to review the potential influence of internal (person-related) factors on listening effort. The purpose of Part 2 was to present, in support of Part 1, preliminary data illustrating the interactive effects of an external factor (task demand) and an internal factor (evaluative threat) on autonomic nervous system measures. For Part 1, we provided a brief narrative review of motivation and stress as modulators of listening effort. For Part 2, we described preliminary data from a study using a repeated-measures (2 × 2) design involving manipulations of task demand (high, low) and evaluative threat (high, low). The low-demand task consisted of repetition of sentences from a narrative. The high-demand task consisted of answering questions about the narrative, requiring both comprehension and recall. During the high evaluative threat condition, participants were filmed and told that their video recordings would be evaluated by a panel of experts. During the low evaluative threat condition, no filming occurred; participants were instructed to "do your best." Skin conductance (sympathetic nervous system activity) and heart rate variability (HRV, parasympathetic activity) were measured during the listening tasks. The HRV measure was the root mean square of successive differences of adjacent interbeat intervals. Twelve adults with hearing loss participated. Skin conductance increased and HRV decreased relative to baseline (no task) for all listening conditions. Skin conductance increased significantly with an increase in evaluative threat, but only for the more demanding task. There was no significant change in HRV in response to increasing evaluative threat or task demand. Listening effort may be influenced by factors other than task difficulty, as reviewed in Part 1. This idea is supported by the preliminary data indicating that the sympathetic nervous system response to task demand is modulated by social evaluative threat. More work is needed to determine the relative contributions of motivation and emotional stress on physiological responses during listening tasks.
The Raid distributed database system
NASA Technical Reports Server (NTRS)
Bhargava, Bharat; Riedl, John
1989-01-01
Raid, a robust and adaptable distributed database system for transaction processing (TP), is described. Raid is a message-passing system, with server processes on each site to manage concurrent processing, consistent replicated copies during site failures, and atomic distributed commitment. A high-level layered communications package provides a clean location-independent interface between servers. The latest design of the package delivers messages via shared memory in a configuration with several servers linked into a single process. Raid provides the infrastructure to investigate various methods for supporting reliable distributed TP. Measurements on TP and server CPU time are presented, along with data from experiments on communications software, consistent replicated copy control during site failures, and concurrent distributed checkpointing. A software tool for evaluating the implementation of TP algorithms in an operating-system kernel is proposed.
Combinations of Earth Orientation Measurements: SPACE2005, COMB2005, and POLE2005
NASA Technical Reports Server (NTRS)
Gross, Richard S.
2006-01-01
Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, by very long baseline interferometry, and by the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2005, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to January 7, 2006, at daily intervals and is available in versions whose epochs are given at either midnight or noon. The space-geodetic measurements used to generate SPACE2005 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2005, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to January 7, 2006, at daily intervals and which is also available in versions whose epochs are given at either midnight or noon; and (2) POLE2005, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to December 21, 2005, at 30.4375-day intervals.
Combinations of Earth Orientation Measurements: SPACE2003, COMB2003, and POLE2003
NASA Technical Reports Server (NTRS)
Gross, Richard S.
2004-01-01
Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the global positioning system have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2003, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28.0, 1976 to January 31.0, 2004 at daily intervals and is available in versions whose epochs are given at either midnight or noon. The space-geodetic measurements used to generate SPACE2003 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2003, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20.0, 1962 to January 31.0, 2004 at daily intervals and which is also available in versions whose epochs are given at either midnight or noon, and (2) POLE2003, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900 to January 21,2004 at 30.4375-day intervals.
Combinations of Earth Orientation Measurements: SPACE2004, COMB2004, and POLE2004
NASA Technical Reports Server (NTRS)
Gross, Richard R.
2005-01-01
Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the global positioning system have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2004, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to January 22, 2005, at daily intervals and is available in versions whose epochs are given at either midnight or noon. The space-geodetic measurements used to generate SPACE2004 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2004, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to January 22, 2005, at daily intervals and which is also available in versions whose epochs are given at either midnight or noon, and (2) POLE2004, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to January 20, 2005, at 30.4375-day intervals.
Combinations of Earth Orientation Measurements: SPACE2014, COMB2014, and POLE2014
NASA Technical Reports Server (NTRS)
Ratcliff, J. T.; Gross, R. S.
2015-01-01
Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2013, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to June 30, 2014, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2013 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2013, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to June 30, 2014, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2013, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to June 22, 2014, at 30.4375-day intervals.
Combinations of Earth Orientation Measurements: SPACE2011, COMB2011, and POLE2011
NASA Technical Reports Server (NTRS)
Ratcliff, J. T.; Gross, R. S.
2013-01-01
Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2011, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to July 13, 2012, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2011 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2011, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to July 13, 2012, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2011, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to June 21, 2012, at 30.4375-day intervals.
Combinations of Earth Orientation Measurements: SPACE2013, COMB2013, and POLE2013
NASA Technical Reports Server (NTRS)
Ratcliff, J. T.; Gross, R. S.
2015-01-01
Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2013, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to June 30, 2014, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2013 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2013, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to June 30, 2014, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2013, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to June 22, 2014, at 30.4375-day intervals.
Combinations of Earth Orientation Measurements: SPACE2016, COMB2016, and POLE2016
NASA Technical Reports Server (NTRS)
Ratcliff, J. T.; Gross, R. S.
2017-01-01
Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2016, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to June 30, 2017, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2016 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2016, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to June 30, 2017, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2016, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to June 22, 2017, at 30.4375-day intervals.
Combinations of Earth Orientation Measurements: SPACE2012, COMB2012, and POLE2012
NASA Technical Reports Server (NTRS)
Ratcliff, J. T.; Gross, R. S.
2013-01-01
Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2012, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to April 26, 2013, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2012 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2012, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to April 26, 2013, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2012, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to May 22, 2013, at 30.4375-day intervals.
NASA Astrophysics Data System (ADS)
Fernandez-Balbuena, A. A.; Vazquez-Molini, D.; García-Botella, A.; Romo, J.; Serrano, Ana
2017-09-01
The photometry and radiometry measurement is a well-developed field. The necessity of measuring optical systems performance involves the use of several techniques like Gonio-photometry. The Gonio photometers are a precise measurement tool that is used in the lighting area like office, luminaire head car lighting, concentrator /collimator measurement and all the designed and fabricated optical systems that works with light. There is one disadvantage in this kind of measurements that obtain the intensity polar curves and the total flux of the optical system. In the industry, there are good Gonio photometers that are precise and reliable but they are very expensive and the measurement time is long. In industry the cost can be of minor importance but measuring time that is around 30 minutes is of major importance due to trained staff cost. We have designed a system to measure photometry in real time; it consists in a curved screen to get a huge measurement angle and a CCD. The system to be measured projects light onto the screen and the CCD records a video of the screen obtaining an image of the projected profile. A complex calibration permits to trace screen data (x,y,z) to intensity polar curve (I,αγ). This intensity is obtained in candels (cd) with an image + processing time below one second.
Simard, Marc; Sirois, Caroline; Candas, Bernard
2018-05-01
To validate and compare performance of an International Classification of Diseases, tenth revision (ICD-10) version of a combined comorbidity index merging conditions of Charlson and Elixhauser measures against individual measures in the prediction of 30-day mortality. To select a weight derivation method providing optimal performance across ICD-9 and ICD-10 coding systems. Using 2 adult population-based cohorts of patients with hospital admissions in ICD-9 (2005, n=337,367) and ICD-10 (2011, n=348,820), we validated a combined comorbidity index by predicting 30-day mortality with logistic regression. To appreciate performance of the Combined index and both individual measures, factors impacting indices performance such as population characteristics and weight derivation methods were accounted for. We applied 3 scoring methods (Van Walraven, Schneeweiss, and Charlson) and determined which provides best predictive values. Combined index [c-statistics: 0.853 (95% confidence interval: CI, 0.848-0.856)] performed better than original Charlson [0.841 (95% CI, 0.835-0.844)] or Elixhauser [0.841 (95% CI, 0.837-0.844)] measures on ICD-10 cohort. All weight derivation methods provided close high discrimination results for the Combined index (Van Walraven: 0.852, Schneeweiss: 0.851, Charlson: 0.849). Results were consistent across both coding systems. The Combined index remains valid with both ICD-9 and ICD-10 coding systems and the 3 weight derivation methods evaluated provided consistent high performance across those coding systems.
NASA Astrophysics Data System (ADS)
Celik, Sukru; Guner, Sait Baris; Ozturk, Kemal; Ozturk, Ozgur
Magnetic levitation force measurements of HTS samples are performed with the use of liquid nitrogen. It is both convenient and cheap. However, the temperature of the sample cannot be changed (77 K) and there is problem of frost. So, it is necessary to build another type of system to measure the levitation force high Tc superconductor at different temperatures. In this study, we fabricated YBaCuO superconducting by top-seeding-melting-growth (TSMG) technique and measured vertical forces of them at FC (Field Cooling) and ZFC (Zero Field Cooling) regimes by using our new designed magnetic levitation force measurement system. It was used to investigate the three-dimensional levitation force and lateral force in the levitation system consisting of a cylindrical magnet and a permanent cylindrical superconductor at different temperatures (37, 47, 57, 67 and 77 K).
Optical stretching as a tool to investigate the mechanical properties of lipid bilayers†
Solmaz, Mehmet E.; Sankhagowit, Shalene; Biswas, Roshni; Mejia, Camilo A.; Povinelli, Michelle L.; Malmstadt, Noah
2013-01-01
Measurements of lipid bilayer bending modulus by various techniques produce widely divergent results. We attempt to resolve some of this ambiguity by measuring bending modulus in a system that can rapidly process large numbers of samples, yielding population statistics. This system is based on optical stretching of giant unilamellar vesicles (GUVs) in a microfluidic dual-beam optical trap (DBOT). The microfluidic DBOT system is used here to measure three populations of GUVs with distinct lipid compositions. We find that gel-phase membranes are significantly stiffer than liquid-phase membranes, consistent with previous reports. We also find that the addition of cholesterol does not alter the bending modulus of membranes composed of a monounsaturated phospholipid. PMID:24244843
NASA Technical Reports Server (NTRS)
Welch, Sharon S.; Clemmons, James I., Jr.; Shelton, Kevin J.; Duncan, Walter C.
1994-01-01
An optical measurement system (OMS) has been designed and tested for a large gap magnetic suspension system (LGMSS). The LGMSS will be used to study control laws for magnetic suspension systems for vibration isolation and pointing applications. The LGMSS features six degrees of freedom and consists of a planar array of electromagnets that levitate and position a cylindrical element containing a permanent magnet core. The OMS provides information on the location and orientation of the element to the LGMSS control system to stabilize suspension. The hardware design of this optical sensing system and the tracking algorithms are presented. The results of analyses and experiments are presented that define the accuracy limits of the optical sensing system and that quantify the errors in position estimation.
NASA Astrophysics Data System (ADS)
Zhao, Ziyue; Zhu, Jigui; Yang, Linghui; Lin, Jiarui
2015-10-01
The present scanning system consists of an industrial robot and a line-structured laser sensor which uses the industrial robot as a position instrument to guarantee the accuracy. However, the absolute accuracy of an industrial robot is relatively poor compared with the good repeatability in the manufacturing industry. This paper proposes a novel method using the workspace measurement and positioning system (wMPS) to remedy the lack of accuracy of the industrial robot. In order to guarantee the positioning accuracy of the system, the wMPS which is a laser-based measurement technology designed for large-volume metrology applications is brought in. Benefitting from the wMPS, this system can measure different cell-areas by the line-structured laser sensor and fuse the measurement data of different cell-areas by using the wMPS accurately. The system calibration which is the procedure to acquire and optimize the structure parameters of the scanning system is also stated in detail in this paper. In order to verify the feasibility of the system for scanning the large free-form surface, an experiment is designed to scan the internal surface of the door of a car-body in white. The final results show that the measurement data of the whole measuring areas have been jointed perfectly and there is no mismatch in the figure especially in the hole measuring areas. This experiment has verified the rationality of the system scheme, the correctness and effectiveness of the relevant methods.
NASA Astrophysics Data System (ADS)
Tlalolini, David; Ritou, Mathieu; Rabréau, Clément; Le Loch, Sébastien; Furet, Benoit
2018-05-01
The paper presents an electromagnetic system that has been developed to measure the quasi-static and dynamic behavior of machine-tool spindle, at different spindle speeds. This system consists in four Pulse Width Modulation amplifiers and four electromagnets to produce magnetic forces of ± 190 N for the static mode and ± 80 N for the dynamic mode up to 5 kHz. In order to measure the Frequency Response Function (FRF) of spindle, the applied force is required, which is a key issue. A dynamic force model is proposed in order to obtain the load from the measured current in the amplifiers. The model depends on the exciting frequency and on the magnetic characteristics of the system. The predicted force at high speed is validated with a specific experiment and the performance limits of the experimental device are investigated. The FRF obtained with the electromagnetic system is compared to a classical tap test measurement.
Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei
2018-01-01
High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (H c2 ) and critical temperature (T c ). The critical current (I c ) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new I c measurement system that can carry out accurate I c measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The I c measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa 2 Cu 3 O 7-x (YBCO) tapes I c determination with different temperatures and magnetic fields.
NASA Astrophysics Data System (ADS)
Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei
2018-01-01
High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (Hc2) and critical temperature (Tc). The critical current (Ic) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new Ic measurement system that can carry out accurate Ic measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The Ic measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa2Cu3O7-x(YBCO) tapes Ic determination with different temperatures and magnetic fields.
Two-Dimensional Automatic Measurement for Nozzle Flow Distribution Using Improved Ultrasonic Sensor
Zhai, Changyuan; Zhao, Chunjiang; Wang, Xiu; Wang, Ning; Zou, Wei; Li, Wei
2015-01-01
Spray deposition and distribution are affected by many factors, one of which is nozzle flow distribution. A two-dimensional automatic measurement system, which consisted of a conveying unit, a system control unit, an ultrasonic sensor, and a deposition collecting dish, was designed and developed. The system could precisely move an ultrasonic sensor above a pesticide deposition collecting dish to measure the nozzle flow distribution. A sensor sleeve with a PVC tube was designed for the ultrasonic sensor to limit its beam angle in order to measure the liquid level in the small troughs. System performance tests were conducted to verify the designed functions and measurement accuracy. A commercial spray nozzle was also used to measure its flow distribution. The test results showed that the relative error on volume measurement was less than 7.27% when the liquid volume was 2 mL in trough, while the error was less than 4.52% when the liquid volume was 4 mL or more. The developed system was also used to evaluate the flow distribution of a commercial nozzle. It was able to provide the shape and the spraying width of the flow distribution accurately. PMID:26501288
Perceived Stress and Wellness in Early Adolescents Using the Neuman Systems Model
ERIC Educational Resources Information Center
Yarcheski, Thomas J.; Mahon, Noreen E.; Yarcheski, Adela; Hanks, Michele M.
2010-01-01
The purpose of this study was to examine the relationship between perceived stress and wellness in early adolescents and to test primary appraisal as a mediator of this relationship using the Neuman Systems Model as the primary framework. The sample consisted of 144 adolescents, ages 12-14, who responded to instruments measuring perceived stress,…
Solar hot water system installed at Mobile, Alabama
NASA Technical Reports Server (NTRS)
1980-01-01
The system consists of six rows of ten collectors and three rows of eleven collectors (1990 square feet) mounted on the roof. Griswald flow control valves were installed to regulate the flow to each row. Two Heliotrope electronic thermometers with a combined capability of measuring the temperatures of 22 different locations were installed for monitoring purposes.
ERIC Educational Resources Information Center
Boyd, Aimee M.; Dodd, Barbara; Fitzpatrick, Steven
2013-01-01
This study compared several exposure control procedures for CAT systems based on the three-parameter logistic testlet response theory model (Wang, Bradlow, & Wainer, 2002) and Masters' (1982) partial credit model when applied to a pool consisting entirely of testlets. The exposure control procedures studied were the modified within 0.10 logits…
In-situ characterization of wildland fire behavior
Bret Butler; D. Jimenez; J. Forthofer; Paul Sopko; K. Shannon; Jim Reardon
2010-01-01
A system consisting of two enclosures has been developed to characterize wildand fire behavior: The first enclosure is a sensor/data logger combination that measures and records convective/radiant energy released by the fire. The second is a digital video camera housed in a fire proof enclosure that records visual images of fire behavior. Together this system provides...
Jones, Conor M; DeWalt, Darren A; Huang, I-Chan
Poor asthma control in children is related to impaired patient-reported outcomes (PROs; eg, fatigue, depressive symptoms, anxiety), but less well studied is the effect of PROs on children's school performance and sleep outcomes. In this study we investigated whether the consistency status of PROs over time affected school functioning and daytime sleepiness in children with asthma. Of the 238 children with asthma enrolled in the Patient-Reported Outcomes Measurement Information System (PROMIS) Pediatric Asthma Study, 169 children who provided survey data for all 4 time points were used in the analysis. The child's PROs, school functioning, and daytime sleepiness were measured 4 times within a 15-month period. PRO domains included asthma impact, pain interference, fatigue, depressive symptoms, anxiety, and mobility. Each child was classified as having poor/fair versus good PROs per meaningful cut points. The consistency status of each domain was classified as consistently poor/fair if poor/fair status was present for at least 3 time points; otherwise, the status was classified as consistently good. Seemingly unrelated regression was performed to test if consistently poor/fair PROs predicted impaired school functioning and daytime sleepiness at the fourth time point. Consistently poor/fair in all PRO domains was significantly associated with impaired school functioning and excessive daytime sleepiness (Ps < .01) after controlling for the influence of the child's age, sex, and race/ethnicity. Children with asthma with consistently poor/fair PROs are at risk of poor school functioning and daytime sleepiness. Developing child-friendly PRO assessment systems to track PROs can inform potential problems in the school setting. Copyright © 2017 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Measurement and evaluation of transit travel time reliability
DOT National Transportation Integrated Search
2011-01-01
Transportation system customers need consistency in their daily travel times to enable them to plan their daily : activities, whether that is a commuter on their way to work, a company setting up delivery schedules for justintime : manufacturin...
Packaging and distributing ecological data from multisite studies
NASA Technical Reports Server (NTRS)
Olson, R. J.; Voorhees, L. D.; Field, J. M.; Gentry, M. J.
1996-01-01
Studies of global change and other regional issues depend on ecological data collected at multiple study areas or sites. An information system model is proposed for compiling diverse data from dispersed sources so that the data are consistent, complete, and readily available. The model includes investigators who collect and analyze field measurements, science teams that synthesize data, a project information system that collates data, a data archive center that distributes data to secondary users, and a master data directory that provides broader searching opportunities. Special attention to format consistency is required, such as units of measure, spatial coordinates, dates, and notation for missing values. Often data may need to be enhanced by estimating missing values, aggregating to common temporal units, or adding other related data such as climatic and soils data. Full documentation, an efficient data distribution mechanism, and an equitable way to acknowledge the original source of data are also required.
The reliability of WorkWell Systems Functional Capacity Evaluation: a systematic review
2014-01-01
Background Functional capacity evaluation (FCE) determines a person’s ability to perform work-related tasks and is a major component of the rehabilitation process. The WorkWell Systems (WWS) FCE (formerly known as Isernhagen Work Systems FCE) is currently the most commonly used FCE tool in German rehabilitation centres. Our systematic review investigated the inter-rater, intra-rater and test-retest reliability of the WWS FCE. Methods We performed a systematic literature search of studies on the reliability of the WWS FCE and extracted item-specific measures of inter-rater, intra-rater and test-retest reliability from the identified studies. Intraclass correlation coefficients ≥ 0.75, percentages of agreement ≥ 80%, and kappa coefficients ≥ 0.60 were categorised as acceptable, otherwise they were considered non-acceptable. The extracted values were summarised for the five performance categories of the WWS FCE, and the results were classified as either consistent or inconsistent. Results From 11 identified studies, 150 item-specific reliability measures were extracted. 89% of the extracted inter-rater reliability measures, all of the intra-rater reliability measures and 96% of the test-retest reliability measures of the weight handling and strength tests had an acceptable level of reliability, compared to only 67% of the test-retest reliability measures of the posture/mobility tests and 56% of the test-retest reliability measures of the locomotion tests. Both of the extracted test-retest reliability measures of the balance test were acceptable. Conclusions Weight handling and strength tests were found to have consistently acceptable reliability. Further research is needed to explore the reliability of the other tests as inconsistent findings or a lack of data prevented definitive conclusions. PMID:24674029
Optimization of CO2 Surface Flux using GOSAT Total Column CO2: First Results for 2009-2010
NASA Astrophysics Data System (ADS)
Basu, S.; Houweling, S.
2011-12-01
Constraining surface flux estimates of CO2 using satellite measurements has been one of the long-standing goals of the atmospheric inverse modeling community. We present the first results of inverting GOSAT total column CO2 measurements for obtaining global monthly CO2 flux maps over one year (June 2009 to May 2010). We use the SRON RemoTeC retrieval of CO2 for our inversions. The SRON retrieval has been shown to have no bias when compared to TCCON total column measurements, and latitudinal gradients of the retrieved CO2 are consistent with gradients deduced from the surface flask network [Butz et al, 2011]. This makes this retrieval an ideal candidate for atmospheric inversions, which are highly sensitive to spurious gradients. Our inversion system is analogous to the CarbonTracker (CT) data assimilation system; it is initialized with the prior CO2 fluxes of CT, and uses the same atmospheric transport model, i.e., TM5. The two major differences are (a) we add GOSAT CO2 data to the inversion in addition to flask data, and (b) we use a 4DVAR optimization system instead of a Kalman filter. We compare inversions using (a) only GOSAT total column CO2 measurements, (b) only surface flask CO2 measurements, and (c) the joint data set of GOSAT and surface flask measurements. We validate GOSAT-only inversions against the NOAA surface flask network and joint inversions against CONTRAIL and other aircraft campaigns. We see that inverted fluxes from a GOSAT-only inversion are consistent with fluxes from a stations-only inversion, reaffirming the low biases in SRON retrievals. From the joint inversion, we estimate the amount of added constraints upon adding GOSAT total column measurements to existing surface layer measurements.
A safety-based decision making architecture for autonomous systems
NASA Technical Reports Server (NTRS)
Musto, Joseph C.; Lauderbaugh, L. K.
1991-01-01
Engineering systems designed specifically for space applications often exhibit a high level of autonomy in the control and decision-making architecture. As the level of autonomy increases, more emphasis must be placed on assimilating the safety functions normally executed at the hardware level or by human supervisors into the control architecture of the system. The development of a decision-making structure which utilizes information on system safety is detailed. A quantitative measure of system safety, called the safety self-information, is defined. This measure is analogous to the reliability self-information defined by McInroy and Saridis, but includes weighting of task constraints to provide a measure of both reliability and cost. An example is presented in which the safety self-information is used as a decision criterion in a mobile robot controller. The safety self-information is shown to be consistent with the entropy-based Theory of Intelligent Machines defined by Saridis.
NASA Astrophysics Data System (ADS)
Laskar, S.; Bordoloi, S.
2016-01-01
This paper presents an instrumentation system to measure the degradation in lubricating oil using a bare, tapered and bent multi-mode optical fiber (BTBMOF) sensor probe and a temperature probe. The sensor system consists of (i) a bare, tapered and bent multi-mode optical fiber (BTBMOF) as optical sensor along with a laser source and a LDR (Light Dependent Resistor) as detector (ii) a temperature sensor (iii) a ATmega microcontroller based data acquisition system and (iv) a trained ANN for processing and calibration. The BTBMOF sensor and the temperature sensor are used to provide the measure of refractive index (RI) and the temperature of a lubricating oil sample. A microcontroller based instrumentation system with trained ANN algorithm has been developed to determine the degradation of the lubricating oil sample by sampling the readings of the optical fiber sensor, and the temperature sensor.
Probe systems for static pressure and cross-stream turbulence intensity
NASA Technical Reports Server (NTRS)
Rossow, Vernon, J.
1991-01-01
A recent study of total-pressure probes for use in highly turbulent streams is extended herein by developing probe systems that measure time-averaged static or ambient pressure and turbulence intensity. Arrangements of tubular probes of circular and elliptical cross section are described that measure the pressure at orifices on the sides of the probes to obtain different responses to the cross-stream velocity fluctuations. When the measured data are combined to remove the effect of the presence of the probes on the local pressure, the time-averaged static pressure and the cross-stream components of turbulence intensity can be determined. If a system of total pressure tubes, as described in an accompanying paper, is added to the static pressure group to form a single cluster, redundant measurements are obtained that permit accuracy and consistency checks.
Frequency-modulated laser ranging sensor with closed-loop control
NASA Astrophysics Data System (ADS)
Müller, Fabian M.; Böttger, Gunnar; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Schröder, Henning; Schneider-Ramelow, Martin
2018-02-01
Advances in autonomous driving and robotics are creating high demand for inexpensive and mass-producible distance sensors. A laser ranging system (Lidar), based on the frequency-modulated continuous-wave (FMCW) method is built in this work. The benefits of an FMCW Lidar system are the low-cost components and the performance in comparison to conventional time-of-flight Lidar systems. The basic system consists of a DFB laser diode (λ= 1308 nm) and an asymmetric fiber-coupled Mach-Zehnder interferometer with a fixed delay line in one arm. Linear tuning of the laser optical frequency via injection current modulation creates a beat signal at the interferometer output. The frequency of the beat signal is proportional to the optical path difference in the interferometer. Since the laser frequency-to-current response is non-linear, a closed-loop feed-back system is designed to improve the tuning linearity, and consequently the measurement resolution. For fast active control, an embedded system with FPGA is used, resulting in a nearly linear frequency tuning, realizing a narrow peak in the Fourier spectrum of the beat signal. For free-space measurements, a setup with two distinct interferometers is built. The fully fiber-coupled Mach-Zehnder reference interferometer is part of the feed-back loop system, while the other - a Michelson interferometer - has a free-space arm with collimator lens and reflective target. A resolution of 2:0 mm for a 560 mm distance is achieved. The results for varying target distances show high consistency and a linear relation to the measured beat-frequency.
GPM Solar Array Gravity Negated Deployment Testing
NASA Technical Reports Server (NTRS)
Penn, Jonathan; Johnson, Chris; Lewis, Jesse; Dear, Trevin; Stewart, Alphonso
2014-01-01
NASA Goddard Space Flight Center (GSFC) successfully developed a g-negation support system for use on the solar arrays of the Global Precipitation Measurement (GPM) Satellite. This system provides full deployment capability at the subsystem and observatory levels. In addition, the system provides capability for deployed configuration first mode frequency verification testing. The system consists of air pads, a support structure, an air supply, and support tables. The g-negation support system was used to support all deployment activities for flight solar array deployment testing.
Advanced dosimetry systems for the space transport and space station
NASA Technical Reports Server (NTRS)
Wailly, L. F.; Schneider, M. F.; Clark, B. C.
1972-01-01
Advanced dosimetry system concepts are described that will provide automated and instantaneous measurement of dose and particle spectra. Systems are proposed for measuring dose rate from cosmic radiation background to greater than 3600 rads/hr. Charged particle spectrometers, both internal and external to the spacecraft, are described for determining mixed field energy spectra and particle fluxes for both real time onboard and ground-based computer evaluation of the radiation hazard. Automated passive dosimetry systems consisting of thermoluminescent dosimeters and activation techniques are proposed for recording the dose levels for twelve or more crew members. This system will allow automatic onboard readout and data storage of the accumulated dose and can be transmitted to ground after readout or data records recovered with each crew rotation.
Single-chip microcomputer for image processing in the photonic measuring system
NASA Astrophysics Data System (ADS)
Smoleva, Olga S.; Ljul, Natalia Y.
2002-04-01
The non-contact measuring system has been designed for rail- track parameters control on the Moscow Metro. It detects some significant parameters: rail-track width, rail-track height, gage, rail-slums, crosslevel, pickets, and car speed. The system consists of three subsystems: non-contact system of rail-track width, height, and gage inspection, non-contact system of rail-slums inspection and subsystem for crosslevel, speed, and pickets detection. Data from subsystems is transferred to pre-processing unit. In order to process data received from subsystems, the single-chip signal processor ADSP-2185 must be used due to providing required processing speed. After data will be processed, it is send to PC, which processes it and outputs it in the readable form.
NASA Technical Reports Server (NTRS)
Couch, Richard H.; Rowland, Carroll W.; Ellis, K. Scott; Blythe, Michael P.; Regan, Curtis P.; Koch, Michael R.; Antill, Charles W.; Kitchen, Wayne L.; Cox, John W.; Delorme, Joseph F.
1991-01-01
Engineering aspects are presented of the design, fabrication, integration, and operation of the Lidar In-Space Technology Experiment (LITE) for flight aboard the Space Shuttle in mid-1993. The LITE system is being developed by NASA/Langley Research Center and will be used to detect stratospheric and tropospheric aerosols, probe the planetary boundary layer, measure cloud top heights, and measure atmospheric temperature and density in the 10- to 40-km range. The system consists of a nominal telescope receiver 1 meter in diameter, a three-color Nd:YAG laser transmitter, and the system electronics. The system makes extensive use of Space Shuttle resources for electrical power, thermal control, and command and data handling.
Alcoverro, Benoit; Le Pichon, Alexis
2005-04-01
The implementation of the infrasound network of the International Monitoring System (IMS) for the enforcement of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) increases the effort in the design of suitable noise reducer systems. In this paper we present a new design consisting of low impedance elements. The dimensioning and the optimization of this discrete mechanical system are based on numerical simulations, including a complete electroacoustical modeling and a realistic wind-noise model. The frequency response and the noise reduction obtained for a given wind speed are compared to statistical noise measurements in the [0.02-4] Hz frequency band. The effects of the constructive parameters-the length of the pipes, inner diameters, summing volume, and number of air inlets-are investigated through a parametric study. The studied system consists of 32 air inlets distributed along an overall diameter of 16 m. Its frequency response is flat up to 4 Hz. For a 2 m/s wind speed, the maximal noise reduction obtained is 15 dB between 0.5 and 4 Hz. At lower frequencies, the noise reduction is improved by the use of a system of larger diameter. The main drawback is the high-frequency limitation introduced by acoustical resonances inside the pipes.
Repeatability of standard metabolic rate (SMR) in a small fish, the spined loach (Cobitis taenia).
Maciak, Sebastian; Konarzewski, Marek
2010-10-01
Significant repeatability of a trait of interest is an essential assumption for undertaking studies of phenotypic variability. It is especially important in studies on highly variable traits, such as metabolic rates. Recent publications suggest that resting/basal metabolic rate of homeotherms is repeatable across wide range of species. In contrast, studies on the consistency of standard metabolic rate (SMR) in ectotherms, particularly fish, are scarce. Here we present a comprehensive analysis of several important technical aspects of body mass-corrected SMR measurements and its repeatability in a small (average weight approximately 3g) fish, the spined loach (Cobitis taenia). First we demonstrated that release of oxygen from the walls of metabolic chambers exposed to hypoxic conditions did not confound SMR measurements. Next, using principle of propagation of measurement uncertainties we demonstrated that in aquatic systems, measurement error is significantly higher in open than closed respirometry setups. The measurement error for SMR of a small fish determined in a closed aquatic system is comparable to that obtainable using top-notch open-flow systems used for air-breathing terrestrial animals. Using a closed respirometer we demonstrated that body mass-corrected SMR in spined loaches was repeatable under both normoxia and hypoxia over a 5-month period (Pearson correlation r=0.68 and r=0.73, respectively) as well as across both conditions (intraclass correlation coefficient tau=0.30). In these analyses we accounted for possible effect of oxygen consumption of the oxygen electrode on repeatability of SMR. Significant SMR consistency was accompanied by significant repeatability of body mass (intraclass correlation coefficient tau=0.86). To our knowledge, this is the first study showing long-term repeatability of body mass and SMR in a small fish, and is consistent with the existence of heritable variation of these two traits. 2010 Elsevier Inc. All rights reserved.
Volumetric measurement of tank volume
NASA Technical Reports Server (NTRS)
Walter, Richard T. (Inventor); Vanbuskirk, Paul D. (Inventor); Weber, William F. (Inventor); Froebel, Richard C. (Inventor)
1991-01-01
A method is disclosed for determining the volume of compressible gas in a system including incompressible substances in a zero-gravity environment consisting of measuring the change in pressure (delta P) for a known volume change rate (delta V/delta t) in the polytrophic region between isothermal and adiabatic conditions. The measurements are utilized in an idealized formula for determining the change in isothermal pressure (delta P sub iso) for the gas. From the isothermal pressure change (delta iso) the gas volume is obtained. The method is also applicable to determination of gas volume by utilizing work (W) in the compression process. In a passive system, the relationship of specific densities can be obtained.
Device and method for measuring the energy content of hot and humid air streams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosen, H. N.; Girod, G. F.; Kent, A. C.
1985-12-24
a portable device and method for measuring enthalpy and humidity of humid air from a space or flow channel at temperatures from 80/sup 0/ to 400/sup 0/ F. is described. the device consists of a psychrometer for measuring wet-bulb temperature, a vacuum pump for inducing sample air flow through the unit, a water-heating system for accurate psychrometer readings, an electronic computer system for evaluation of enthalpy and humidity from corrected and averaged values of wet- and dry- bulb temperatures, and a monitor for displaying the values. The device is programmable by the user to modify evaluation methods as necessary.
Identification of boiler inlet transfer functions and estimation of system parameters
NASA Technical Reports Server (NTRS)
Miles, J. H.
1972-01-01
An iterative computer method is described for identifying boiler transfer functions using frequency response data. An objective penalized performance measure and a nonlinear minimization technique are used to cause the locus of points generated by a transfer function to resemble the locus of points obtained from frequency response measurements. Different transfer functions can be tried until a satisfactory empirical transfer function of the system is found. To illustrate the method, some examples and some results from a study of a set of data consisting of measurements of the inlet impedance of a single tube forced flow boiler with inserts are given.
Advanced S-Band studies using the TDRSS communications satellite
NASA Technical Reports Server (NTRS)
Jenkins, Jeffrey D.; Osborne, William P.; Fan, Yiping
1994-01-01
This report will describe the design, implementation, and results of a propagation experiment which used TDRSS to transmit spread signals at S-Band to an instrumented mobile receiver. The results consist of fade measurements and distribution functions in 21 environments across the Continental United States (CONUS). From these distribution functions, some idea may be gained about what system designers should expect for excess path loss in many mobile environments. Some of these results may be compared against similar measurements made with narrowband beacon measurements. Such comparisons provide insight into what gains the spread signaling system may or may not have in multipath and shadowing environments.
NASA Technical Reports Server (NTRS)
Bilbro, James W.; Johnson, Steven C.; Rothermel, Jeffry
1987-01-01
A coherent CO2 lidar operating in a master oscillator power amplifier configuration (MOPA) is described for both ground-based and airborne operation. Representative data taken from measurements against stationary targets in both the ground-based and airborne configurations are shown for the evaluation of the frequency stability of the system. Examples of data are also given which show the results of anomalous system operation. Overall results demonstrate that velocity measurements can be performed consistently to an accuracy of + or - 0.5 m/s and in some cases + or - 0.1 m/s.
Zhao, Bo; Wang, Lei; Tan, Jiu-Bin
2015-01-01
This paper presents the design and realization of a three degrees of freedom (DOFs) displacement measurement system composed of Hall sensors, which is built for the XYθz displacement measurement of the short stroke stage of the reticle stage of lithography. The measurement system consists of three pairs of permanent magnets mounted on the same plane on the short stroke stage along the Y, Y, X directions, and three single axis Hall sensors correspondingly mounted on the frame of the reticle stage. The emphasis is placed on the decoupling and magnetic field fitting of the three DOFs measurement system. The model of the measurement system is illustrated, and the XY positions and θZ rotation of the short stroke stage can be obtained by decoupling the sensor outputs. A magnetic field fitting by an elliptic function-based compensation method is proposed. The practical field intensity of a permanent magnet at a certain plane height can be substituted for the output voltage of a Hall sensors, which can be expressed by the elliptic function through experimental data as the crucial issue to calculate the three DOFs displacement. Experimental results of the Hall sensor displacement measurement system are presented to validate the proposed three DOFs measurement system. PMID:26370993
Clinical Gait Evaluation of Patients with Lumbar Spine Stenosis.
Sun, Jun; Liu, Yan-Cheng; Yan, Song-Hua; Wang, Sha-Sha; Lester, D Kevin; Zeng, Ji-Zhou; Miao, Jun; Zhang, Kuan
2018-02-01
The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3, MiniSun, CA) has been developed for clinical gait evaluation, and this study was designed to evaluate the accuracy and reliability of IDEEA3 for the gait measurement of lumbar spinal stenosis (LSS) patients. Twelve healthy volunteers were recruited to compare gait cycle, cadence, step length, velocity, and number of steps between a motion analysis system and a high-speed video camera. Twenty hospitalized LSS patients were recruited for the comparison of the five parameters between the IDEEA3 and GoPro camera. Paired t-test, intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plots were used for the data analysis. The ratios of GoPro camera results to motion analysis system results, and the ratios of IDEEA3 results to GoPro camera results were all around 1.00. All P-values of paired t-tests for gait cycle, cadence, step length, and velocity were greater than 0.05, while all the ICC and CCC results were above 0.950 with P < 0.001. The measurements for gait cycle, cadence, step length, velocity, and number of steps with the GoPro camera are highly consistent with the measurements with the motion analysis system. The measurements for IDEEA3 are consistent with those for the GoPro camera. IDEEA3 can be effectively used in the gait measurement of LSS patients. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Development of a real-time radon monitoring system for simultaneous measurements in multiple sites
NASA Astrophysics Data System (ADS)
Yamamoto, S.; Yamasoto, K.; Iida, T.
1999-12-01
A real-time radon monitoring system that can simultaneously measure radon concentrations in multiple sites was developed and tested. The system consists of maximum of four radon detectors, optical fiber cables and a data acquisition personal computer. The radon detector uses a plastic scintillation counter that collects radon daughters in the chamber electrostatically. The applied voltage on the photocathode for the photomultiplier tube (PMT) acts as an electrode for radon daughters. The thickness of the plastic scintillator was thin, 50 /spl mu/m, so as to minimize the background counts due to the environmental gamma rays or beta particles. The energy discriminated signals from the radon detectors are fed to the data acquisition personal computer via optical fiber cables. The system made it possible to measure the radon concentrations in multiple sites simultaneously.
AmeriFlux Measurement Component (AMC) Instrument Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reichl, Ken; Biraud, Sebastien C.
2016-04-01
An AMC system was installed at the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility North Slope of Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling photosynthetically active radiation (PAR) sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System.more » Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape.« less
A New PC and LabVIEW Package Based System for Electrochemical Investigations.
Stević, Zoran; Andjelković, Zoran; Antić, Dejan
2008-03-15
The paper describes a new PC and LabVIEW software package based system forelectrochemical research. An overview of well known electrochemical methods, such aspotential measurements, galvanostatic and potentiostatic method, cyclic voltammetry andEIS is given. Electrochemical impedance spectroscopy has been adapted for systemscontaining large capacitances. For signal generation and recording of the response ofinvestigated electrochemical cell, a measurement and control system was developed, basedon a PC P4. The rest of the hardware consists of a commercially available AD-DA converterand an external interface for analog signal processing. The interface is a result of authorsown research. The software platform for desired measurement methods is LabVIEW 8.2package, which is regarded as a high standard in the area of modern virtual instruments. Thedeveloped system was adjusted, tested and compared with commercially available systemand ORCAD simulation.
NASA Astrophysics Data System (ADS)
Jasek, Alina; Zimnoch, Miroslaw; Gorczyca, Zbigniew; Chmura, Lukasz; Necki, Jaroslaw
2014-05-01
The presented work is a part of comprehensive study aimed at thorough characterization of carbon cycle in the urban environment of Krakow, southern Poland. In the framework of this study two independent methods were employed to quantify biogenic CO2 flux in the city: (i) closed chambers, and (ii) Relaxed Eddy Accumulation (REA). The results of a three-day intensive intercomparison campaign performed in July 2013 and utilizing both measurement methods are reported here. The chamber method is a widely used approach for measurements of gas exchange between the soil and the atmosphere. The system implemented in this study consisted of a single chamber operating in a closed-dynamic mode, combined with Vaisala CarboCAP infrared CO2 sensor in a mobile setup. An alternative flux measurement method, covering larger area is represented by REA, which is a modification of the eddy covariance method. It consists of a 3D anemometer (Gill Windmaster Pro) and the system collecting updraft and downdraft samples to 5-litre Tedlar bags. The CO2 mixing ratios in the collected samples are measured by Picarro G2101i analyzer. The setup consists of two sets of bags so that the sampling can be performed continuously with 15-min temporal resolution. A 48-hectares open meadow located close the city center was chosen as a test site for comparison of the two methods of CO2 flux measurements outlined above. In the middle of the meadow a 3-metre high tripod was installed with the anemometer and REA inlet system. For a period of 46 hours the system was measuring net CO2 flux from the surrounding area. A meteorological conditions and intensity of photosynthetically active radiation (PAR) were also recorded. In the same time, CO2 flux from several points around the REA inlet was measured with the chamber system, resulting in 93 values for both respiration and net CO2 flux. Chamber results show rather homogenous distribution of the soil CO2 flux (the mean value equal to 40.9 ± 2.2 mmol/m2h), with slight increase towards the city centre. Good agreement between the two measurement methods was obtained, with night-time flux ranging from around 10 to 80 mmol/m2h and day-time net flux reaching -88 mmol/m2h at peak PAR intensity. Positive correlation between the net CO2 flux and intensity of PAR was also observed. Acknowledgements: The study was supported by the Ministry of Science and Higher Education (817.N-COST/2010/0) and the statutory funds of the AGH University of Science and Technology (11.11.220.01).
Measurements of Optical Turbulence Parameters Aboard the Aircraft Carrier USS LEXINGTON.
1982-09-30
EFFECTS ON SHIP-TO-SHIP TRACKER PERFORMANCE ...... 10 E. FREQUENCY SPECTRA OF MICROTHERMAL FLUCTUATIONS ............. 13 9. CONCLUSIONS...in Fig. 2. It consisted of a Contel model MT-2 microthermal unit with modified probe system as discussed below, a RMS log amplifier, a HP 59313A 2 oI...probe system provided with the Contel system(4 ) was replaced with the probe assembly built for use in the Harris microthermal probe system(5 ). The
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apel, V.M.; Curilef, S.; Plastino, A.R., E-mail: arplastino@unnoba.edu.ar
We explore the entanglement-related features exhibited by the dynamics of a composite quantum system consisting of a particle and an apparatus (here referred to as the “pointer”) that measures the position of the particle. We consider measurements of finite duration, and also the limit case of instantaneous measurements. We investigate the time evolution of the quantum entanglement between the particle and the pointer, with special emphasis on the final entanglement associated with the limit case of an impulsive interaction. We consider entanglement indicators based on the expectation values of an appropriate family of observables, and also an entanglement measure computedmore » on particular exact analytical solutions of the particle–pointer Schrödinger equation. The general behavior exhibited by the entanglement indicators is consistent with that shown by the entanglement measure evaluated on particular analytical solutions of the Schrödinger equation. In the limit of instantaneous measurements the system’s entanglement dynamics corresponds to that of an ideal quantum measurement process. On the contrary, we show that the entanglement evolution corresponding to measurements of finite duration departs in important ways from the behavior associated with ideal measurements. In particular, highly localized initial states of the particle lead to highly entangled final states of the particle–pointer system. This indicates that the above mentioned initial states, in spite of having an arbitrarily small position uncertainty, are not left unchanged by a finite-duration position measurement process. - Highlights: • We explore entanglement features of a quantum position measurement. • We consider instantaneous and finite-duration measurements. • We evaluate the entanglement of exact time-dependent particle–pointer states.« less
Carreau, Joseph H; Bastrom, Tracey; Petcharaporn, Maty; Schulte, Caitlin; Marks, Michelle; Illés, Tamás; Somoskeöy, Szabolcs; Newton, Peter O
2014-03-01
Reproducibility study of SterEOS 3-dimensional (3D) software in large, idiopathic scoliosis (IS) spinal curves. To determine the accuracy and reproducibility of various 3D, software-generated radiographic measurements acquired from a 2-dimensional (2D) imaging system. SterEOS software allows a user to reconstruct a 3D spinal model from an upright, biplanar, low-dose, X-ray system. The validity and internal consistency of this system have not been tested in large IS curves. EOS images from 30 IS patients with curves greater than 50° were collected for analysis. Three observers blinded to the study protocol conducted repeated, randomized, manual 2D measurements, and 3D software generated measurements from biplanar images acquired from an EOS Imaging system. Three-dimensional measurements were repeated using both the Full 3D and Fast 3D guided processes. A total of 180 (120 3D and 60 2D) sets of measurements were obtained of coronal (Cobb angle) and sagittal (T1-T12 and T4-T12 kyphosis; L1-S1 and L1-L5; and pelvic tilt, pelvic incidence, and sacral slope) parameters. Intra-class correlation coefficients were compared, as were the calculated differences in values generated by SterEOS 3D software and manual 2D measurements. The 95% confidence intervals of the mean differences in measures were calculated as an estimate of reproducibility. Average intra-class correlation coefficients were excellent: 0.97, 0.97, and 0.93 for Full 3D, Fast 3D, and 2D measures, respectively (p = .11). Measurement errors for some sagittal measures were significantly lower with the 3D techniques. Both the Full 3D and Fast 3D techniques provided consistent measurements of axial plane vertebral rotation. SterEOS 3D reconstruction spine software creates reproducible measurements in all 3 planes of deformity in curves greater than 50°. Advancements in 3D scoliosis imaging are expected to improve our understanding and treatment of idiopathic scoliosis. Copyright © 2014 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Refaat, T. F.; Singh, U. N.; Petros, M.; Yu, J.; Remus, R.; Ismail, S.
2017-12-01
An airborne Integrated Path Differential Absorption (IPDA) lidar has been developed and validated at NASA Langley Research Center for atmospheric carbon dioxide column measurements. The instrument consists of a tunable, high-energy 2-μm double pulse laser transmitter and 0.4 m telescope receiver coupled to an InGaAs pin detection system. The instrument was validated for carbon dioxide (CO2) measurements from ground and airborne platforms, using a movable lidar trailer and the NASA B-200 aircraft. Airborne validation was conducted over the ocean by comparing the IPDA CO2 optical depth measurement to optical depth model derived using NOAA airborne CO2 air-sampling. Another airborne validation was conducted over land vegetation by comparing the IPDA measurement to a model derived using on-board in-situ measurements using an absolute, non-dispersive infrared gas analyzer (LiCor 840A). IPDA range measurements were also compared to rangefinder and Global Positioning System (GPS) records during ground and airborne validation, respectively. Range measurements from the ground indicated a 0.93 m IPDA range measurement uncertainty, which is limited by the transmitted laser pulse and detection system properties. This uncertainty increased to 2.80 and 7.40 m over ocean and land, due to fluctuations in ocean surface and ground elevations, respectively. IPDA CO2 differential optical depth measurements agree with both models. Consistent CO2 optical depth biases were well correlated with the digitizer full scale input range settings. CO2 optical depth measurements over ocean from 3.1 and 6.1 km altitudes indicated 0.95% and 0.83% uncertainty, respectively, using 10 second (100 shots) averaging. Using the same averaging 0.40% uncertainty was observed over land, from 3.4 km altitude, due to higher surface reflectivity, which increases the return signal power and enhances the signal-to-noise ratio. However, less uncertainty is observed at higher altitudes due to reduced signal shot noise, indicating that detection system noise-equivalent-power dominates the error. These results show that the IPDA technique is well suited for space-based platforms, which includes larger column content integration that enhances the measurement sensitivity.
Support of validation of SAGE 2 data
NASA Technical Reports Server (NTRS)
Copeland, Gary E.
1986-01-01
An error analysis of differential absorption lidar (DIAL) measurements of stratospheric ozone from a Space Shuttle is discussed. A transmitter system consisting of a KrF excimer laser pumping gas cells of H2 or D2 producing output wavelengths in the near UV is shown to be useful for the measurement of ozone in an altitude range from 15 to 50 km.
Interaction between colloidal particles on an oil-water interface in dilute and dense phases.
Parolini, Lucia; Law, Adam D; Maestro, Armando; Buzza, D Martin A; Cicuta, Pietro
2015-05-20
The interaction between micron-sized charged colloidal particles at polar/non-polar liquid interfaces remains surprisingly poorly understood for a relatively simple physical chemistry system. By measuring the pair correlation function g(r) for different densities of polystyrene particles at the decane-water interface, and using a powerful predictor-corrector inversion scheme, effective pair-interaction potentials can be obtained up to fairly high densities, and these reproduce the experimental g(r) in forward simulations, so are self consistent. While at low densities these potentials agree with published dipole-dipole repulsion, measured by various methods, an apparent density dependence and long range attraction are obtained when the density is higher. This condition is thus explored in an alternative fashion, measuring the local mobility of colloids when confined by their neighbors. This method of extracting interaction potentials gives results that are consistent with dipolar repulsion throughout the concentration range, with the same magnitude as in the dilute limit. We are unable to rule out the density dependence based on the experimental accuracy of our data, but we show that incomplete equilibration of the experimental system, which would be possible despite long waiting times due to the very strong repulsions, is a possible cause of artefacts in the inverted potentials. We conclude that to within the precision of these measurements, the dilute pair potential remains valid at high density in this system.
Cavity-Enhanced Quantum-Cascade Laser-Based Instrument for Trace gas Measurements
NASA Astrophysics Data System (ADS)
Provencal, R.; Gupta, M.; Owano, T.; Baer, D.; Ricci, K.; O'Keefe, A.
2005-12-01
An autonomous instrument based on Off-Axis Integrated Cavity Output Spectroscopy has been successfully deployed for measurements of CO in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument consists of a measurement cell comprised of two high reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data acquisition electronics, and data analysis software. The instrument reports CO mixing ratio at a 1-Hz rate based on measured absorption, gas temperature and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41000 ft, the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights. We will also present recent development efforts to extend the instrument's capabilities for the measurements of CH4, N2O and CO in real time.
Togasaki, Daniel M; Hsu, Albert; Samant, Meghana; Farzan, Bijan; DeLanney, Louis E; Langston, J William; Di Monte, Donato A; Quik, Maryka
2005-06-30
Investigations using models of neurologic disease frequently involve quantifying animal motor activity. We developed a simple method for measuring motor activity using a computer-based video system (the Webcam system) consisting of an inexpensive video camera connected to a personal computer running customized software. Images of the animals are captured at half-second intervals and movement is quantified as the number of pixel changes between consecutive images. The Webcam system allows measurement of motor activity of the animals in their home cages, without devices affixed to their bodies. Webcam quantification of movement was validated by correlation with measures simultaneously obtained by two other methods: measurement of locomotion by interruption of infrared beams; and measurement of general motor activity using portable accelerometers. In untreated squirrel monkeys, correlations of Webcam and locomotor activity exceeded 0.79, and correlations with general activity counts exceeded 0.65. Webcam activity decreased after the monkeys were rendered parkinsonian by treatment with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP), but the correlations with the other measures of motor activity were maintained. Webcam activity also correlated with clinical ratings of parkinsonism. These results indicate that the Webcam system is reliable under both untreated and experimental conditions and is an excellent method for quantifying motor activity in animals.
Wei, Wenhui; Gao, Zhaohui; Gao, Shesheng; Jia, Ke
2018-01-01
In order to meet the requirements of autonomy and reliability for the navigation system, combined with the method of measuring speed by using the spectral redshift information of the natural celestial bodies, a new scheme, consisting of Strapdown Inertial Navigation System (SINS)/Spectral Redshift (SRS)/Geomagnetic Navigation System (GNS), is designed for autonomous integrated navigation systems. The principle of this SINS/SRS/GNS autonomous integrated navigation system is explored, and the corresponding mathematical model is established. Furthermore, a robust adaptive central difference particle filtering algorithm is proposed for this autonomous integrated navigation system. The simulation experiments are conducted and the results show that the designed SINS/SRS/GNS autonomous integrated navigation system possesses good autonomy, strong robustness and high reliability, thus providing a new solution for autonomous navigation technology. PMID:29642549
TIME-RESOLVED SPECTROSCOPY OF THE POLAR EU CANCRI IN THE OPEN CLUSTER MESSIER 67
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Kurtis A.; Howell, Steve B.; Liebert, James
2013-05-15
We present time-resolved spectroscopic and polarimetric observations of the AM Her system EU Cnc. EU Cnc is located near the core of the old open cluster Messier 67; new proper motion measurements indicate that EU Cnc is indeed a member of the star cluster, and this system therefore is useful to constrain the formation and evolution of magnetic cataclysmic variables. The spectra exhibit two-component emission features with independent radial velocity variations as well as time-variable cyclotron emission indicating a magnetic field strength of 41 MG. The period of the radial velocity and cyclotron hump variations are consistent with the previouslymore » known photometric period, and the spectroscopic flux variations are consistent in amplitude with previous photometric amplitude measurements. The secondary star is also detected in the spectrum. We also present polarimetric imaging measurements of EU Cnc that show a clear detection of polarization, and the degree of polarization drops below our detection threshold at phases when the cyclotron emission features are fading or not evident. The combined data are all consistent with the interpretation that EU Cnc is a low-state polar in the cluster Messier 67. The mass function of the system gives an estimate of the accretor mass of M{sub WD} {>=} 0.68 M{sub Sun} with M{sub WD} Almost-Equal-To 0.83 M{sub Sun} for an average inclination. We are thus able to place a lower limit on the progenitor mass of the accreting white dwarf of {>=}1.43 M{sub Sun }.« less
Design and realization of an automatic weather station at island
NASA Astrophysics Data System (ADS)
Chen, Yong-hua; Li, Si-ren
2011-10-01
In this paper, the design and development of an automatic weather station monitoring is described. The proposed system consists of a set of sensors for measuring meteorological parameters (temperature, wind speed & direction, rain fall, visibility, etc.). To increase the reliability of the system, wind speed & direction are measured redundantly with duplicate sensors. The sensor signals are collected by the data logger CR1000 at several analog and digital inputs. The CR1000 and the sensors form a completely autonomous system which works with the other systems installed in the container. Communication with the master PC is accomplished over the method of Code Division Multiple Access (CDMA) with the Compact Caimore6550P CDMA DTU. The data are finally stored in tables on the CPU as well as on the CF-Card. The weather station was built as an efficient autonomous system which operates with the other systems to provide the required data for a fully automatic measurement system.
Development of a continuous radon concentration monitoring system in underground soil
NASA Astrophysics Data System (ADS)
Yamamoto, S.; Tarutani, K.; Yamasoto, K.; Iskandar, D.; Iida, T.
2001-06-01
A continuous radon (Rn-222) concentration monitoring system for use in underground soil was developed and tested. The system consists of a 19-mm-diameter, 1100-mm-long detector assembly and a microprocessor based data logger. A small volume chamber is installed at the tip of the detector assembly. A thin ZnS(Ag) scintillator film inside the chamber and a photomultiplier tube (PMT) detect alpha particles from radon and its daughters. When the system is in measurement, the detector part is buried into underground soil. An energy resolution of approximately 70% full width half maximum (FWHM) was obtained for 5.5 MeV alpha particles from Am-241. Both the rise time and fall time for the system were measured to be approximately 1-2 h. Temporal variations in underground radon concentration at different depths were investigated simultaneously using four sets of the developed system. The results confirmed that the developed system is useful for continuous measurement of radon concentration in underground soil.
Video camera system for locating bullet holes in targets at a ballistics tunnel
NASA Technical Reports Server (NTRS)
Burner, A. W.; Rummler, D. R.; Goad, W. K.
1990-01-01
A system consisting of a single charge coupled device (CCD) video camera, computer controlled video digitizer, and software to automate the measurement was developed to measure the location of bullet holes in targets at the International Shooters Development Fund (ISDF)/NASA Ballistics Tunnel. The camera/digitizer system is a crucial component of a highly instrumented indoor 50 meter rifle range which is being constructed to support development of wind resistant, ultra match ammunition. The system was designed to take data rapidly (10 sec between shoots) and automatically with little operator intervention. The system description, measurement concept, and procedure are presented along with laboratory tests of repeatability and bias error. The long term (1 hour) repeatability of the system was found to be 4 microns (one standard deviation) at the target and the bias error was found to be less than 50 microns. An analysis of potential errors and a technique for calibration of the system are presented.
Calibration of NASA Turbulent Air Motion Measurement System
NASA Technical Reports Server (NTRS)
Barrick, John D. W.; Ritter, John A.; Watson, Catherine E.; Wynkoop, Mark W.; Quinn, John K.; Norfolk, Daniel R.
1996-01-01
A turbulent air motion measurement system (TAMMS) was integrated onboard the Lockheed 188 Electra airplane (designated NASA 429) based at the Wallops Flight Facility in support of the NASA role in global tropospheric research. The system provides air motion and turbulence measurements from an airborne platform which is capable of sampling tropospheric and planetary boundary-layer conditions. TAMMS consists of a gust probe with free-rotating vanes mounted on a 3.7-m epoxy-graphite composite nose boom, a high-resolution inertial navigation system (INS), and data acquisition system. A variation of the tower flyby method augmented with radar tracking was implemented for the calibration of static pressure position error and air temperature probe. Additional flight calibration maneuvers were performed remote from the tower in homogeneous atmospheric conditions. System hardware and instrumentation are described and the calibration procedures discussed. Calibration and flight results are presented to illustrate the overall ability of the system to determine the three-component ambient wind fields during straight and level flight conditions.
NASA Astrophysics Data System (ADS)
Ghosh, Abhijit; Nirala, A. K.; Yadav, H. L.
2018-03-01
We have designed and fabricated four LDA optical setups consisting of aberration compensated four different compact two hololens imaging systems. We have experimentally investigated and realized a hololens recording geometry which is interferogram of converging spherical wavefront with mutually coherent planar wavefront. Proposed real time monitoring and actual fringe field analysis techniques allow complete characterizations of fringes formed at measurement volume and permit to evaluate beam quality, alignment and fringe uniformity with greater precision. After experimentally analyzing the fringes formed at measurement volume by all four imaging systems, it is found that fringes obtained using compact two hololens imaging systems get improved both qualitatively and quantitatively compared to that obtained using conventional imaging system. Results indicate qualitative improvement of non-uniformity in fringe thickness and micro intensity variations perpendicular to the fringes, and quantitative improvement of 39.25% in overall average normalized standard deviations of fringe width formed by compact two hololens imaging systems compare to that of conventional imaging system.
Unmanned Aircraft Systems For CryoSat-2 Validation
NASA Astrophysics Data System (ADS)
Crocker, Roger Ian; Maslanik, James A.
2011-02-01
A suite of sensors has been assembled to map surface elevation with fine-resolution from small unmanned aircraft systems (UAS). The sensor package consists of a light detecting and ranging (LIDAR) instrument, an inertial measurement unit (IMU), a GPS module, and digital still and video cameras. It has been utilized to map ice sheet topography in Greenland and to measure sea ice freeboard and roughness in Fram Strait. Data collected during these campaigns illustrate its potential to compliment ongoing CryoSat-2 (CS-2) calibration and validation efforts.
Simplified optical fiber RGB system in evaluating intrinsic quality of Sala mango
NASA Astrophysics Data System (ADS)
Yahaya, Ommi Kalsom Mardziah; Jafri, Mohd. Zubir Mat; Aziz, Azlan Abdul; Omar, Ahmad Fairuz
2015-06-01
This study presents an alternative approach for the nondestructive assessment of fruit quality parameters with the use of a simplified optical fiber red-green-blue system (OF-RGB). The optical sensor system presented in this work is designed to rapidly measure the firmness, acidity, and soluble solid content of an intact Sala mango on the basis of color properties. The system consists of three light-emitting diodes with peak emission at 635 (red), 525 (green), and 470 nm (blue), as well as a single photodetector capable of sensing visible light. The measurements were conducted using the reflectance technique. The analyses were conducted by comparing the results obtained through the proposed system with those measured using two commercial spectrometers, namely, QE65000 and FieldSpec 3. The developed RGB system showed satisfactory accuracy in the measurement of acidity (R2=0.795) and firmness (R2=0.761), but a relatively lower accuracy in the measurement of soluble solid content (R2=0.593) of intact mangoes. The results obtained through OF-RGB are comparable with those measured by QE65000 and FieldSpec 3. This system is a promising new technology with rapid response, easy operation, and low cost with potential applications in the nondestructive assessment of quality attributes.
Terminator field-aligned current system: A new finding from model-assimilated data set (MADS)
NASA Astrophysics Data System (ADS)
Zhu, L.; Schunk, R. W.; Scherliess, L.; Sojka, J. J.; Gardner, L. C.; Eccles, J. V.; Rice, D.
2013-12-01
Physics-based data assimilation models have been recognized by the space science community as the most accurate approach to specify and forecast the space weather of the solar-terrestrial environment. The model-assimilated data sets (MADS) produced by these models constitute an internally consistent time series of global three-dimensional fields whose accuracy can be estimated. Because of its internal consistency of physics and completeness of descriptions on the status of global systems, the MADS has also been a powerful tool to identify the systematic errors in measurements, reveal the missing physics in physical models, and discover the important dynamical physical processes that are inadequately observed or missed by measurements due to observational limitations. In the past years, we developed a data assimilation model for the high-latitude ionospheric plasma dynamics and electrodynamics. With a set of physical models, an ensemble Kalman filter, and the ingestion of data from multiple observations, the data assimilation model can produce a self-consistent time-series of the complete descriptions of the global high-latitude ionosphere, which includes the convection electric field, horizontal and field-aligned currents, conductivity, as well as 3-D plasma densities and temperatures, In this presentation, we will show a new field-aligned current system discovered from the analysis of the MADS produced by our data assimilation model. This new current system appears and develops near the ionospheric terminator. The dynamical features of this current system will be described and its connection to the active role of the ionosphere in the M-I coupling will be discussed.
Dai, Qian; Pan, De-lu; He, Xian-qiang; Zhu, Qian-kun; Gong, Fang; Huang, Hai-qing
2015-11-01
In situ measurement of water spectrum is the basis of the validation of the ocean color remote sensing. The traditional method to obtain the water spectrum is based on the shipboard measurement at limited stations, which is difficult to meet the requirement of validation of ocean color remote sensing in the highly dynamic coastal waters. To overcome this shortage, continuously observing systems of water spectrum have been developed in the world. However, so far, there are still few high-frequency observation systems of the water spectrum in coastal waters, especially in the highly turbid and high-dynamic waters. Here, we established a high-frequency water-spectrum observing system based on tower in the Hangzhou Bay. The system measures the water spectrum at a step of 3 minutes, which can fully match the satellite observation. In this paper, we primarily developed a data processing method for the tower-based high-frequency water spectrum data, to realize automatic judgment of clear sky, sun glint, platform shadow, and weak illumination, etc. , and verified the processing results. The results show that the normalized water-leaving radiance spectra obtained through tower observation have relatively high consistency with the shipboard measurement results, with correlation coefficient of more than 0. 99, and average relative error of 9.96%. In addition, the long-term observation capability of the tower-based high-frequency water-spectrum observing system was evaluated, and the results show that although the system has run for one year, the normalized water-leaving radiance obtained by this system have good consistency with the synchronously measurement by Portable spectrometer ASD in respect of spectral shape and value, with correlation coefficient of more than 0.90 and average relative error of 6.48%. Moreover, the water spectra from high-frequency observation by the system can be used to effectively monitor the rapid dynamic variation in concentration of suspended materials with tide. The tower-based high-frequency water-spectrum observing system provided rich in situ spectral data for the validation of ocean color remote sensing in turbid waters, especially for validation of the high temporal-resolution geostationary satellite ocean color remote sensing.
Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.
Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi
2011-01-01
Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.
Development of a survey instrument to measure patient experience of integrated care.
Walker, Kara Odom; Stewart, Anita L; Grumbach, Kevin
2016-06-01
Healthcare systems are working to move towards more integrated, patient-centered care. This study describes the development and testing of a multidimensional self-report measure of patients' experiences of integrated care. Random-digit-dial telephone survey in 2012 of 317 adults aged 40 years or older in the San Francisco region who had used healthcare at least twice in the past 12 months. One-time cross-sectional survey; psychometric evaluation to confirm dimensions and create multi-item scales. Survey data were analyzed using VARCLUS and confirmatory factor analysis and internal consistency reliability testing. Scales measuring five domains were confirmed: coordination within and between care teams, navigation (arranging appointments and visits), communication between specialist and primary care doctor, and communication between primary care doctor and specialist. Four of these demonstrated excellent internal consistency reliability. Mean scale scores indicated low levels of integration. These scales measuring integrated care capture meaningful domains of patients' experiences of health care. The low levels of care integration reported by patients in the study sample suggest that these types of measures should be considered in ongoing evaluations of health system performance and improvement. Further research should examine whether differences in patient experience of integrated care are associated with differences in the processes and outcomes of care received.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vercher, E.; Pena, M.P.; Martinez-Andreu, A.
Isobaric experimental data of vapor-liquid equilibrium for the ethanol-water-strontium bromide system at different mole fractions of strontium bromide have been measured at 100.6 kPa. Data were correlated by Jaques and Furter's method. Thermodynamic consistency was checked by Herington's method with satisfactory results.
In Situ Measurements of Spectral Emissivity of Materials for Very High Temperature Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
G. Cao; S. J. Weber; S. O. Martin
2011-08-01
An experimental facility for in situ measurements of high-temperature spectral emissivity of materials in environments of interest to the gas-cooled very high temperature reactor (VHTR) has been developed. The facility is capable of measuring emissivities of seven materials in a single experiment, thereby enhancing the accuracy in measurements due to even minor systemic variations in temperatures and environments. The system consists of a cylindrical silicon carbide (SiC) block with seven sample cavities and a deep blackbody cavity, a detailed optical system, and a Fourier transform infrared spectrometer. The reliability of the facility has been confirmed by comparing measured spectral emissivitiesmore » of SiC, boron nitride, and alumina (Al2O3) at 600 C against those reported in literature. The spectral emissivities of two candidate alloys for VHTR, INCONEL{reg_sign} alloy 617 (INCONEL is a registered trademark of the Special Metals Corporation group of companies) and SA508 steel, in air environment at 700 C were measured.« less
Surface complexation modeling of Cu(II) adsorption on mixtures of hydrous ferric oxide and kaolinite
Lund, Tracy J; Koretsky, Carla M; Landry, Christopher J; Schaller, Melinda S; Das, Soumya
2008-01-01
Background The application of surface complexation models (SCMs) to natural sediments and soils is hindered by a lack of consistent models and data for large suites of metals and minerals of interest. Furthermore, the surface complexation approach has mostly been developed and tested for single solid systems. Few studies have extended the SCM approach to systems containing multiple solids. Results Cu adsorption was measured on pure hydrous ferric oxide (HFO), pure kaolinite (from two sources) and in systems containing mixtures of HFO and kaolinite over a wide range of pH, ionic strength, sorbate/sorbent ratios and, for the mixed solid systems, using a range of kaolinite/HFO ratios. Cu adsorption data measured for the HFO and kaolinite systems was used to derive diffuse layer surface complexation models (DLMs) describing Cu adsorption. Cu adsorption on HFO is reasonably well described using a 1-site or 2-site DLM. Adsorption of Cu on kaolinite could be described using a simple 1-site DLM with formation of a monodentate Cu complex on a variable charge surface site. However, for consistency with models derived for weaker sorbing cations, a 2-site DLM with a variable charge and a permanent charge site was also developed. Conclusion Component additivity predictions of speciation in mixed mineral systems based on DLM parameters derived for the pure mineral systems were in good agreement with measured data. Discrepancies between the model predictions and measured data were similar to those observed for the calibrated pure mineral systems. The results suggest that quantifying specific interactions between HFO and kaolinite in speciation models may not be necessary. However, before the component additivity approach can be applied to natural sediments and soils, the effects of aging must be further studied and methods must be developed to estimate reactive surface areas of solid constituents in natural samples. PMID:18783619
Arakawa, Takahiro; Sato, Toshiyuki; Iitani, Kenta; Toma, Koji; Mitsubayashi, Kohji
2017-04-18
Various volatile organic compounds can be found in human transpiration, breath and body odor. In this paper, a novel two-dimensional fluorometric imaging system, known as a "sniffer-cam" for ethanol vapor released from human breath and palm skin was constructed and validated. This imaging system measures ethanol vapor concentrations as intensities of fluorescence through an enzymatic reaction induced by alcohol dehydrogenase (ADH). The imaging system consisted of multiple ultraviolet light emitting diode (UV-LED) excitation sheet, an ADH enzyme immobilized mesh substrate and a high-sensitive CCD camera. This imaging system uses ADH for recognition of ethanol vapor. It measures ethanol vapor by measuring fluorescence of nicotinamide adenine dinucleotide (NADH), which is produced by an enzymatic reaction on the mesh. This NADH fluorometric imaging system achieved the two-dimensional real-time imaging of ethanol vapor distribution (0.5-200 ppm). The system showed rapid and accurate responses and a visible measurement, which could lead to an analysis of metabolism function at real time in the near future.
Zheng, Yongbin; Chen, Huimin; Zhou, Zongtan
2018-05-23
The accurate angle measurement of objects outside the linear field of view (FOV) is a challenging task for a strapdown semi-active laser seeker and is not yet well resolved. Considering the fact that the strapdown semi-active laser seeker is equipped with GPS and an inertial navigation system (INS) on a missile, in this work, we present an angle measurement method based on the fusion of the seeker’s data and GPS and INS data for a strapdown semi-active laser seeker. When an object is in the nonlinear FOV or outside the FOV, by solving the problems of space consistency and time consistency, the pitch angle and yaw angle of the object can be calculated via the fusion of the last valid angles measured by the seeker and the corresponding GPS and INS data. The numerical simulation results demonstrate the correctness and effectiveness of the proposed method.
Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi
2017-11-01
This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Jules, Kenol; Hrovat, Kenneth; Kelly, Eric; Reckart, Timothy
2006-01-01
This summary report presents the analysis results of some of the processed acceleration data measured aboard the International Space Station during the period of November 2002 to April 2004. Two accelerometer systems were used to measure the acceleration levels for the activities that took place during Increment-6/8. However, not all of the activities during that period were analyzed in order to keep the size of the report manageable. The National Aeronautics and Space Administration sponsors the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System to support microgravity science experiments that require microgravity acceleration measurements. On April 19, 2001, both the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System units were launched on STS-100 from the Kennedy Space Center for installation on the International Space Station. The Microgravity Acceleration Measurement System unit was flown to the station in support of science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System unit was flown to support experiments requiring vibratory acceleration measurement. Both acceleration systems are also used in support of the vehicle microgravity requirements verification as well as in support of the International Space Station support cadre. The International Space Station Increment-6/8 reduced gravity environment analysis presented in this report uses acceleration data collected by both sets of accelerometer systems: 1. The Microgravity Acceleration Measurement System, which consists of two sensors: the Orbital Acceleration Research Experiment Sensor Subsystem, a low frequency range sensor (up to 1 Hz), is used to characterize the quasi-steady environment for payloads and vehicle, and the High Resolution Accelerometer Package, which is used to characterize the vibratory environment up to 100 Hz. 2. The Space Acceleration Measurement System measures vibratory acceleration data in the range of 0.01 to 400 Hz. This summary report presents analysis of some selected quasi-steady and vibratory activities measured by these accelerometers during Increment-6/8 from November 2002 to April 2004.
Ennis, William J; Hoffman, Rachel A; Gurtner, Geoffrey C; Kirsner, Robert S; Gordon, Hanna M
2017-08-01
Chronic wounds are increasing in prevalence and are a costly problem for the US healthcare system and throughout the world. Typically outcomes studies in the field of wound care have been limited to small clinical trials, comparative effectiveness cohorts and attempts to extrapolate results from claims databases. As a result, outcomes in real world clinical settings may differ from these published studies. This study presents a modified intent-to-treat framework for measuring wound outcomes and measures the consistency of population based outcomes across two distinct settings. In this retrospective observational analysis, we describe the largest to date, cohort of patient wound outcomes derived from 626 hospital based clinics and one academic tertiary care clinic. We present the results of a modified intent-to-treat analysis of wound outcomes as well as demographic and descriptive data. After applying the exclusion criteria, the final analytic sample includes the outcomes from 667,291 wounds in the national sample and 1,788 wounds in the academic sample. We found a consistent modified intent to treat healing rate of 74.6% from the 626 clinics and 77.6% in the academic center. We recommend that a standard modified intent to treat healing rate be used to report wound outcomes to allow for consistency and comparability in measurement across providers, payers and healthcare systems. © 2017 by the Wound Healing Society.
Measuring task-related changes in heart rate variability.
Moses, Ziev B; Luecken, Linda J; Eason, James C
2007-01-01
Small beat-to-beat differences in heart rate are the result of dynamic control of the cardiovascular system by the sympathetic and parasympathetic nervous systems. Heart rate variability (HRV) has been positively correlated with both mental and physical health. While many studies measure HRV under rest conditions, few have measured HRV during stressful situations. We describe an experimental protocol designed to measure baseline, task, and recovery values of HRV as a function of three different types of stressors. These stressors involve an attention task, a cold pressor test, and a videotaped speech presentation. We found a measurable change in heart rate in participants (n=10) during each task (all p's < 0.05). The relative increase or decrease from pre-task heart rate was predicted by task (one-way ANOVA, p= 0.0001). Spectral analysis of HRV during the attention task revealed consistently decreased measures of both high (68+/-7%, mean+/-S.E.) and low (62+/-13%) frequency HRV components as compared to baseline. HRV spectra for the cold pressor and speech tasks revealed no consistent patterns of increase or decrease from baseline measurements. We also found no correlation in reactivity measures between any of our tasks. These findings suggest that each of the tasks in our experimental design elicits a different type of stress response in an individual. Our experimental approach may prove useful to biobehavioral researchers searching for factors that determine individual differences in responses to stress in daily life.
Decoding carotid pressure waveforms recorded by laser Doppler vibrometry: Effects of rebreathing
NASA Astrophysics Data System (ADS)
Casaccia, Sara; Sirevaag, Erik J.; Richter, Edward; O'Sullivan, Joseph A.; Scalise, Lorenzo; Rohrbaugh, John W.
2014-05-01
The principal goal of this study was to assess the capability of the laser Doppler vibrometry (LDV) method for assessing cardiovascular activity. A rebreathing task was used to provoke changes within individuals in cardiac and vascular performance. The rebreathing task is known to produce multiple effects, associated with changes in autonomic drive as well as alterations in blood gases. The rise in CO2 (hypercapnia), in particular, produces changes in the cerebral and systemic circulation. The results from a rebreathing task (involving rebreathing the same air in a rubber bag) are presented for 35 individuals. The LDV pulse was measured from a site overlying the carotid artery. For comparison and validation purposes, several conventional measures of cardiovascular function were also obtained, with an emphasis on the electrocardiogram (ECG), continuous blood pressure (BP) from the radial artery, and measures of myocardial performance using impedance cardiography (ICG). During periods of active rebreathing, ventilation increased. The conventional cardiovascular effects included increased mean arterial BP and systemic vascular resistance, and decreased cardiac stroke volume (SV) and pulse transit time (PTT). These effects were consistent with a pattern of α-adrenergic stimulation. During the immediate post-rebreathing segments, in contrast, mean BP was largely unaffected but pulse BP increased, as did PTT and SV, whereas systemic vascular resistance decreased-a pattern consistent with β-adrenergic effects in combination with the direct effects of hypercapnia on the vascular system. Measures of cardiovascular activity derived from the LDV pulse velocity and displacement waveforms revealed patterns of changes that mirrored the results obtained using conventional measures. In particular, the ratio of the maximum early peak in the LDV velocity pulse to the maximum amplitude of the LDV displacement pulse (in an early systolic interval) closely mirrored the conventional SV effects. Additionally, changes in an augmentation ratio (computed as the maximum amplitude of the LDV displacement pulse during systole / amplitude at the end of the incident wave) were very similar to changes in systemic vascular resistance. Heart rates measured from the ECG and LDV were nearly identical. These preliminary results suggest that measures derived using the non-contact LDV technique can provide surrogate measures for those obtained using impedance cardiography.
To QC or not to QC: the key to a consistent laboratory?
Lane, Michelle; Mitchell, Megan; Cashman, Kara S; Feil, Deanne; Wakefield, Sarah; Zander-Fox, Deirdre L
2008-01-01
A limiting factor in every embryology laboratory is its capacity to grow 'normal' embryos. In human in vitro fertilisation (IVF), there is considerable awareness that the environment of the laboratory itself can alter the quality of the embryos produced and the industry as a whole has moved towards the implementation of auditable quality management systems. Furthermore, in some countries, such as Australia, an established quality management system is mandatory for clinical IVF practice, but such systems are less frequently found in other embryology laboratories. Although the same challenges of supporting consistent and repeatable embryo development are paramount to success in all embryology laboratories, it could be argued that they are more important in a research setting where often the measured outcomes are at an intracellular or molecular level. In the present review, we have outlined the role and importance of quality control and quality assurance systems in any embryo laboratory and have highlighted examples of how simple monitoring can provide consistency and avoid the induction of artefacts, irrespective of the laboratory's purpose, function or species involved.
Automatic real time evaluation of red blood cell elasticity by optical tweezers
NASA Astrophysics Data System (ADS)
Moura, Diógenes S.; Silva, Diego C. N.; Williams, Ajoke J.; Bezerra, Marcos A. C.; Fontes, Adriana; de Araujo, Renato E.
2015-05-01
Optical tweezers have been used to trap, manipulate, and measure individual cell properties. In this work, we show that the association of a computer controlled optical tweezers system with image processing techniques allows rapid and reproducible evaluation of cell deformability. In particular, the deformability of red blood cells (RBCs) plays a key role in the transport of oxygen through the blood microcirculation. The automatic measurement processes consisted of three steps: acquisition, segmentation of images, and measurement of the elasticity of the cells. An optical tweezers system was setup on an upright microscope equipped with a CCD camera and a motorized XYZ stage, computer controlled by a Labview platform. On the optical tweezers setup, the deformation of the captured RBC was obtained by moving the motorized stage. The automatic real-time homemade system was evaluated by measuring RBCs elasticity from normal donors and patients with sickle cell anemia. Approximately 150 erythrocytes were examined, and the elasticity values obtained by using the developed system were compared to the values measured by two experts. With the automatic system, there was a significant time reduction (60 × ) of the erythrocytes elasticity evaluation. Automated system can help to expand the applications of optical tweezers in hematology and hemotherapy.
NASA Technical Reports Server (NTRS)
Vollmer, Bruce E.; Ostrenga, D.; Savtchenko, A.; Johnson, J.; Wei, J.; Teng, W.; Gerasimov, I.
2011-01-01
NASA's Earth Science Program is dedicated to advancing Earth remote sensing and pioneering the scientific use of satellite measurements to improve human understanding of our home planet. Through the MEaSUREs Program, NASA is continuing its commitment to expand understanding of the Earth system using consistent data records. Emphasis is on linking together multiple data sources to form coherent time-series, and facilitating the use of extensive data in the development of comprehensive Earth system models. A primary focus of the MEaSUREs Program is the creation of Earth System Data Records (ESDRs). An ESDR is defined as a unified and coherent set of observations of a given parameter of the Earth system, which is optimized to meet specific requirements for addressing science questions. These records are critical for understanding Earth System processes; for the assessment of variability, long-term trends, and change in the Earth System; and for providing input and validation means to modeling efforts. Seven MEaSUREs projects will be archived and distributed through services at the Goddard Earth Sciences Data and Information Services Center (GES DISC).
NASA Astrophysics Data System (ADS)
Milroy, Daniel J.; Baker, Allison H.; Hammerling, Dorit M.; Jessup, Elizabeth R.
2018-02-01
The Community Earth System Model Ensemble Consistency Test (CESM-ECT) suite was developed as an alternative to requiring bitwise identical output for quality assurance. This objective test provides a statistical measurement of consistency between an accepted ensemble created by small initial temperature perturbations and a test set of CESM simulations. In this work, we extend the CESM-ECT suite with an inexpensive and robust test for ensemble consistency that is applied to Community Atmospheric Model (CAM) output after only nine model time steps. We demonstrate that adequate ensemble variability is achieved with instantaneous variable values at the ninth step, despite rapid perturbation growth and heterogeneous variable spread. We refer to this new test as the Ultra-Fast CAM Ensemble Consistency Test (UF-CAM-ECT) and demonstrate its effectiveness in practice, including its ability to detect small-scale events and its applicability to the Community Land Model (CLM). The new ultra-fast test facilitates CESM development, porting, and optimization efforts, particularly when used to complement information from the original CESM-ECT suite of tools.
ERIC Educational Resources Information Center
Swan, Edward T.; And Others
This study evaluated the success of Teachers Teaching Teachers, an Indiana staff development model in its first implementation. The project consisted of a cadre of teachers from one school system who trained teachers from four other school systems. Participants were evaluated on nine Likert-type pre- and post-measures at each of the four training…
NASA Astrophysics Data System (ADS)
Andreeva, A. V.; Luchinin, V. V.; Kuzmina, K. A.; Klyavinek, A. S.; Karelov, A. E.
2015-12-01
A vibroacoustic fiber optic system that consists of micromechanical components designated for use in medicine and biology is reviewed. A theoretical analysis of a fiber optic microphone is done and its optimal construction parameters are determined. The possibility of using the developed system with magnetic resonance tomography to noninvasively measure man's arterial pressure is specified.
Development of a Web-Enabled Informatics Platform for Manipulation of Gene Expression Data
2004-12-01
genomic platforms such as metabolomics and proteomics , and to federated databases for knowledge management. A successful SBIR Phase I completed...measurements that require sophisticated bioinformatic platforms for data archival, management, integration, and analysis if researchers are to derive...web-enabled bioinformatic platform consisting of a Laboratory Information Management System (LIMS), an Analysis Information Management System (AIMS
Rapid and accurate estimation of release conditions in the javelin throw.
Hubbard, M; Alaways, L W
1989-01-01
We have developed a system to measure initial conditions in the javelin throw rapidly enough to be used by the thrower for feedback in performance improvement. The system consists of three subsystems whose main tasks are: (A) acquisition of automatically digitized high speed (200 Hz) video x, y position data for the first 0.1-0.2 s of the javelin flight after release (B) estimation of five javelin release conditions from the x, y position data and (C) graphical presentation to the thrower of these release conditions and a simulation of the subsequent flight together with optimal conditions and flight for the sam release velocity. The estimation scheme relies on a simulation model and is at least an order of magnitude more accurate than previously reported measurements of javelin release conditions. The system provides, for the first time ever in any throwing event, the ability to critique nearly instantly in a precise, quantitative manner the crucial factors in the throw which determine the range. This should be expected to much greater control and consistency of throwing variables by athletes who use system and could even lead to an evolution of new throwing techniques.
NASA Astrophysics Data System (ADS)
Lu, Zenghai; Kasaragod, Deepa K.; Matcher, Stephen J.
2011-06-01
A phase fluctuation calibration method is presented for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method consists of the generation of a continuous triggered tone-burst waveform rather than an asynchronous waveform by use of a function generator and the removal of the global phases of the measured Jones matrices by use of matrix normalization. This could remove the use of auxiliary optical components for the phase fluctuation compensation in the system, which reduces the system complexity. Phase fluctuation calibration is necessary to obtain the reference Jones matrix by averaging the measured Jones matrices at sample surfaces. Measurements on an equine tendon sample were made by the PS-SS-OCT system to validate the proposed method.
A Miniature System for Separating Aerosol Particles and Measuring Mass Concentrations
Liang, Dao; Shih, Wen-Pin; Chen, Chuin-Shan; Dai, Chi-An
2010-01-01
We designed and fabricated a new sensing system which consists of two virtual impactors and two quartz-crystal microbalance (QCM) sensors for measuring particle mass concentration and size distribution. The virtual impactors utilized different inertial forces of particles in air flow to classify different particle sizes. They were designed to classify particle diameter, d, into three different ranges: d < 2.28 μm, 2.28 μm ≤ d ≤ 3.20 μm, d > 3.20 μm. The QCM sensors were coated with a hydrogel, which was found to be a reliable adhesive for capturing aerosol particles. The QCM sensor coated with hydrogel was used to measure the mass loading of particles by utilizing its characteristic of resonant frequency shift. An integrated system has been demonstrated. PMID:22319317
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, Michael J.
The Hydrogen Fracture Toughness Tester (HFTT) is a mechanical testing machine designed for conducting fracture mechanics tests on materials in high-pressure hydrogen gas. The tester is needed for evaluating the effects of hydrogen on the cracking properties of tritium reservoir materials. It consists of an Instron Model 8862 Electromechanical Test Frame; an Autoclave Engineering Pressure Vessel, an Electric Potential Drop Crack Length Measurement System, associated computer control and data acquisition systems, and a high-pressure hydrogen gas manifold and handling system.
Large scale static tests of a tilt-nacelle V/STOL propulsion/attitude control system
NASA Technical Reports Server (NTRS)
1978-01-01
The concept of a combined V/STOL propulsion and aircraft attitude control system was subjected to large scale engine tests. The tilt nacelle/attitude control vane package consisted of the T55 powered Hamilton Standard Q-Fan demonstrator. Vane forces, moments, thermal and acoustic characteristics as well as the effects on propulsion system performance were measured under conditions simulating hover in and out of ground effect.
Measurement of Rubidium Number Density Under Optically Thick Conditions
2010-11-15
for efficient, high-power laser systems . While these alkali metals offer great promise, there are several issues which need to be resolved. Two such...circulator. The pressure and composition of the diluent within the heat pipe could also be adjusted using the attached gas handling system . The gas...handling system consisted of a vacuum pump, 10 Torr and 1000 Torr baratrons, various valves and a line going to a regulated gas cylinder. The second
A 20-channel magnetoencephalography system based on optically pumped magnetometers
NASA Astrophysics Data System (ADS)
Borna, Amir; Carter, Tony R.; Goldberg, Josh D.; Colombo, Anthony P.; Jau, Yuan-Yu; Berry, Christopher; McKay, Jim; Stephen, Julia; Weisend, Michael; Schwindt, Peter D. D.
2017-12-01
We describe a multichannel magnetoencephalography (MEG) system that uses optically pumped magnetometers (OPMs) to sense the magnetic fields of the human brain. The system consists of an array of 20 OPM channels conforming to the human subject’s head, a person-sized magnetic shield containing the array and the human subject, a laser system to drive the OPM array, and various control and data acquisition systems. We conducted two MEG experiments: auditory evoked magnetic field and somatosensory evoked magnetic field, on three healthy male subjects, using both our OPM array and a 306-channel Elekta-Neuromag superconducting quantum interference device (SQUID) MEG system. The described OPM array measures the tangential components of the magnetic field as opposed to the radial component measured by most SQUID-based MEG systems. Herein, we compare the results of the OPM- and SQUID-based MEG systems on the auditory and somatosensory data recorded in the same individuals on both systems.
Nonlinearity analysis of measurement model for vision-based optical navigation system
NASA Astrophysics Data System (ADS)
Li, Jianguo; Cui, Hutao; Tian, Yang
2015-02-01
In the autonomous optical navigation system based on line-of-sight vector observation, nonlinearity of measurement model is highly correlated with the navigation performance. By quantitatively calculating the degree of nonlinearity of the focal plane model and the unit vector model, this paper focuses on determining which optical measurement model performs better. Firstly, measurement equations and measurement noise statistics of these two line-of-sight measurement models are established based on perspective projection co-linearity equation. Then the nonlinear effects of measurement model on the filter performance are analyzed within the framework of the Extended Kalman filter, also the degrees of nonlinearity of two measurement models are compared using the curvature measure theory from differential geometry. Finally, a simulation of star-tracker-based attitude determination is presented to confirm the superiority of the unit vector measurement model. Simulation results show that the magnitude of curvature nonlinearity measurement is consistent with the filter performance, and the unit vector measurement model yields higher estimation precision and faster convergence properties.
A trifurcated fiber-optic-probe-based optical system designed for AGEs measurement
NASA Astrophysics Data System (ADS)
Wang, Yikun; Zhang, Long; Zhu, Ling; Liu, Yong; Zhang, Gong; Wang, An
2012-03-01
Advanced Glycation End-products (AGEs) are biochemical end-products of non-enzymatic glycation and are formed irreversibly in human serum and skin tissue. AGEs are thought to play an important role in the pathogenesis of diabetes and corresponding complications. All conventional methods for measuring AGEs must take sampling and measure in vitro. These methods are invasive and have the problem of relatively time-consuming. AGEs have fluorescent characteristics. Skin AGEs can be assessed noninvasively by collecting the fluorescence emitted from skin tissue when excited with proper light. However, skin tissue has absorption and scattering effects on fluorescence of AGEs, it is not reliable to evaluate the accumulation of AGEs according the emitted fluorescence but not considering optical properties of skin tissue. In this study, a portable system for detecting AGEs fluorescence and skin reflectance spectrum simultaneously has been developed. The system mainly consists of an ultraviolet light source, a broadband light source, a trifurcated fiber-optic probe, and a compact charge coupled device (CCD) spectrometer. The fiber-optic probe consists of 36 optical fibers which are connected to the ultraviolet light source, 6 optical fibers connected to the broadband light source, and a core fiber connected to the CCD spectrometer. Demonstrative test measurements with the system on skin tissue of 40 healthy subjects have been performed. Using parameters that are calculated from skin reflectance spectrum, the distortion effects caused by skin absorption and scattering can be eliminated, and the integral intensity of corrected fluorescence has a strong correlation with the accumulation of AGEs. The system looks very promising for both laboratory and clinical applications to monitor AGEs related diseases, especially for chronic diabetes and complications.
International Space Station Increment-3 Microgravity Environment Summary Report
NASA Technical Reports Server (NTRS)
Jules, Kenol; Hrovat, Kenneth; Kelly, Eric; McPherson, Kevin; Reckart, Timothy; Grodsinksy, Carlos
2002-01-01
This summary report presents the results of some of the processed acceleration data measured aboard the International Space Station during the period of August to December 2001. Two accelerometer systems were used to measure the acceleration levels for the activities that took place during Increment-3. However, not all of the activities were analyzed for this report due to time constraint and lack of precise timeline information regarding some payload operations and station activities. The National Aeronautics and Space Administration sponsors the Microgravity Acceleration Measurement System and the Space Acceleration Microgravity System to support microgravity science experiments which require microgravity acceleration measurements. On April 19, 2001, both the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System units were launched on STS-100 from the Kennedy Space Center for installation on the International Space Station. The Microgravity Acceleration Measurement System unit was flown to the station in support of science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System unit was flown to support experiments requiring vibratory acceleration measurement. Both acceleration systems are also used in support of the vehicle microgravity requirements verification. The International Space Station Increment-3 reduced gravity environment analysis presented in this report uses acceleration data collected by both sets of accelerometer systems: (1) The Microgravity Acceleration Measurement System, which consists of two sensors: the Orbital Acceleration Research Experiment Sensor Subsystem, a low frequency range sensor (up to 1 Hz), is used to characterize the quasi-steady environment for payloads and vehicle, and the High Resolution Accelerometer Package, which is used to characterize the vibratory environment up to 100 Hz. (2) The Space Acceleration Measurement System, which is a high frequency sensor, measures vibratory acceleration data in the range of 0.01 to 400 Hz. This summary report presents analysis of some selected quasi-steady and vibratory activities measured by these accelerometers during Increment-3 from August to December, 2001.
Experimental active and passive dosimetry systems for the NASA Skylab program
NASA Technical Reports Server (NTRS)
Schneider, M. F.; Janni, J. F.; Ainsworth, G. C.
1972-01-01
Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis.
NASA Technical Reports Server (NTRS)
Resch, G. M.; Hogg, D. E.; Napier, P. J.
1984-01-01
To support very long baseline interferometric experiments, a system has been developed for estimating atmospheric water vapor path delay. The system consists of dual microwave radiometers, one operating at 20.7 GHz and the other at 31.4 GHz. The measured atmospheric brightness temperatures at these two frequencies yield the estimate of the precipitable water present in both vapor and droplets. To determine the accuracy of the system, a series of observations were undertaken, comparing the outputs of two water vapor radiometers with the phase variation observed with two connected elements of the very large array (VLA). The results show that: (1) water vapor fluctuations dominate the residual VLA phase and (2) the microwave radiometers can measure and correct these effects. The rms phase error after correction is typically 15 deg at a wavelength of 6 cm, corresponding to an uncertainty in the path delay of 0.25 cm. The residual uncertainty is consistent with the stability of the microwave radiometer but is still considerably larger than the stability of the VLA. The technique is less successful under conditions of heavy cloud.
Electra: Repetitively Pulsed Angularly Multiplexed KrF Laser System Performance
NASA Astrophysics Data System (ADS)
Wolford, Matthew; Myers, Matthew; Giuliani, John; Sethian, John; Burns, Patrick; Hegeler, Frank; Jaynes, Reginald
2008-11-01
As in a full size fusion power plant beam line, Electra is a multistage laser amplifier system. The multistage amplifier system consists of a commercial discharge laser and two doubled sided electron beam pumped amplifiers. Angular multiplexing is used in the optical layout to provide pulse length control and to maximize laser extraction from the amplifiers. Two angularly multiplexed beams have extracted 30 J of KrF laser light with an aperture 8 x 10 cm^2, which is sufficient to extract over 500 J from the main amplifier and models agree. The main amplifier of Electra in oscillator mode has demonstrated single shot and rep-rate laser energies exceeding 700 J with 100 ns pulsewidth at 248 nm with an aperture 29 x 29 cm^2. Continuous operation of the KrF electron beam pumped oscillator has lasted for more than 2.5 hours without failure at 1 Hz and 2.5 Hz. The measured intensity and pulse energy for durations greater than thousand shots are consistent at measurable rep-rates of 1 Hz, 2.5 Hz and 5 Hz.
NASA Astrophysics Data System (ADS)
Leal-Junior, Arnaldo G.; Vargas-Valencia, Laura; dos Santos, Wilian M.; Schneider, Felipe B. A.; Siqueira, Adriano A. G.; Pontes, Maria José; Frizera, Anselmo
2018-07-01
This paper presents a low cost and highly reliable system for angle measurement based on a sensor fusion between inertial and fiber optic sensors. The system consists of the sensor fusion through Kalman filter of two inertial measurement units (IMUs) and an intensity variation-based polymer optical fiber (POF) curvature sensor. In addition, the IMU was applied as a reference for a compensation technique of POF curvature sensor hysteresis. The proposed system was applied on the knee angle measurement of a lower limb exoskeleton in flexion/extension cycles and in gait analysis. Results show the accuracy of the system, where the Root Mean Square Error (RMSE) between the POF-IMU sensor system and the encoder was below 4° in the worst case and about 1° in the best case. Then, the POF-IMU sensor system was evaluated as a wearable sensor for knee joint angle assessment without the exoskeleton, where its suitability for this purpose was demonstrated. The results obtained in this paper pave the way for future applications of sensor fusion between electronic and fiber optic sensors in movement analysis.
NASA Astrophysics Data System (ADS)
Kuosheng, Jiang; Guanghua, Xu; Tangfei, Tao; Lin, Liang; Yi, Wang; Sicong, Zhang; Ailing, Luo
2014-01-01
This paper presents the theory and implementation of a novel sensor system for measuring the angular speed (AS) of a shaft rotating at a very low speed range, nearly zero speed. The sensor system consists mainly of an eccentric sleeve rotating with the shaft on which the angular speed to be measured, and an eddy current displacement sensor to obtain the profile of the sleeve for AS calculation. When the shaft rotates at constant speed the profile will be a pure sinusoidal trace. However, the profile will be a phase modulated signal when the shaft speed is varied. By applying a demodulating procedure, the AS can be obtained in a straightforward manner. The sensor system was validated experimentally based on a gearbox test rig and the result shows that the AS obtained are consistent with that obtained by a conventional encoder. However, the new sensor gives very smooth and stable traces of the AS, demonstrating its higher accuracy and reliability in obtaining the AS of the low speed operations with speed-up and down transients. In addition, the experiment also shows that it is easy and cost-effective to be realised in different applications such as condition monitoring and process control.
DYNAMICAL MEASUREMENTS OF THE YOUNG UPPER SCORPIUS TRIPLE NTTS 155808-2219
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mace, G. N.; McLean, I. S.; Prato, L.
2012-08-15
The young, low-mass, triple system NTTS 155808-2219 (ScoPMS 20) was previously identified as a {approx}17 day period single-lined spectroscopic binary (SB) with a tertiary component at 0.21 arcsec. Using high-resolution infrared spectra, acquired with NIRSPEC on Keck II, both with and without adaptive optics (AO), we measured radial velocities (RVs) of all three components. Reanalysis of the single-lined visible light observations, made from 1987 to 1993, also yielded RV detections of the three stars. Combining visible light and infrared data to compute the orbital solution produces orbital parameters consistent with the single-lined solution and a mass ratio of q =more » 0.78 {+-} 0.01 for the SB. We discuss the consistency between our results and previously published data on this system, our RV analysis with both observed and synthetic templates, and the possibility that this system is eclipsing, providing a potential method for the determination of the stars' absolute masses. Over the {approx}20 year baseline of our observations, we have measured the acceleration of the SB's center of mass in its orbit with the tertiary. Long-term, AO imaging of the tertiary will eventually yield dynamical data useful for component mass estimates.« less
Design of Advanced Atmospheric Water Vapor Differential Absorption Lidar (DIAL) Detection System
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Luck, William S., Jr.; DeYoung, Russell J.
1999-01-01
The measurement of atmospheric water vapor is very important for understanding the Earth's climate and water cycle. The lidar atmospheric sensing experiment (LASE) is an instrument designed and operated by the Langley Research Center for high precision water vapor measurements. The design details of a new water vapor lidar detection system that improves the measurement sensitivity of the LASE instrument by a factor of 10 are discussed. The new system consists of an advanced, very low noise, avalanche photodiode (APD) and a state-of-the-art signal processing circuit. The new low-power system is also compact and lightweight so that it would be suitable for space flight and unpiloted atmospheric vehicles (UAV) applications. The whole system is contained on one small printed circuit board (9 x 15 sq cm). The detection system is mounted at the focal plane of a lidar receiver telescope, and the digital output is read by a personal computer with a digital data acquisition card.
A synchronized multipoint vision-based system for displacement measurement of civil infrastructures.
Ho, Hoai-Nam; Lee, Jong-Han; Park, Young-Soo; Lee, Jong-Jae
2012-01-01
This study presents an advanced multipoint vision-based system for dynamic displacement measurement of civil infrastructures. The proposed system consists of commercial camcorders, frame grabbers, low-cost PCs, and a wireless LAN access point. The images of target panels attached to a structure are captured by camcorders and streamed into the PC via frame grabbers. Then the displacements of targets are calculated using image processing techniques with premeasured calibration parameters. This system can simultaneously support two camcorders at the subsystem level for dynamic real-time displacement measurement. The data of each subsystem including system time are wirelessly transferred from the subsystem PCs to master PC and vice versa. Furthermore, synchronization process is implemented to ensure the time synchronization between the master PC and subsystem PCs. Several shaking table tests were conducted to verify the effectiveness of the proposed system, and the results showed very good agreement with those from a conventional sensor with an error of less than 2%.
A Synchronized Multipoint Vision-Based System for Displacement Measurement of Civil Infrastructures
Ho, Hoai-Nam; Lee, Jong-Han; Park, Young-Soo; Lee, Jong-Jae
2012-01-01
This study presents an advanced multipoint vision-based system for dynamic displacement measurement of civil infrastructures. The proposed system consists of commercial camcorders, frame grabbers, low-cost PCs, and a wireless LAN access point. The images of target panels attached to a structure are captured by camcorders and streamed into the PC via frame grabbers. Then the displacements of targets are calculated using image processing techniques with premeasured calibration parameters. This system can simultaneously support two camcorders at the subsystem level for dynamic real-time displacement measurement. The data of each subsystem including system time are wirelessly transferred from the subsystem PCs to master PC and vice versa. Furthermore, synchronization process is implemented to ensure the time synchronization between the master PC and subsystem PCs. Several shaking table tests were conducted to verify the effectiveness of the proposed system, and the results showed very good agreement with those from a conventional sensor with an error of less than 2%. PMID:23028250
Rosas, Scott R; Behar, Lenore B; Hydaker, William M
2016-01-01
Establishing a system of care requires communities to identify ways to successfully implement strategies and support positive outcomes for children and their families. Such community transformation is complex and communities vary in terms of their readiness for implementing sustainable community interventions. Assessing community readiness and guiding implementation, specifically for the funded communities implementing a system of care, requires a well-designed tool with sound psychometric properties. This scale development study used the results of a previously published concept mapping study to create, administer, and assess the psychometric characteristics of the System of Care Readiness and Implementation Measurement Scale (SOC-RIMS). The results indicate the SOC-RIMS possesses excellent internal consistency characteristics, measures clearly discernible dimensions of community readiness, and demonstrates the target constructs exist within a broad network of content. The SOC-RIMS can be a useful part of a comprehensive assessment in communities where system of care practices, principles, and philosophies are implemented and evaluated.