Preventing Spacecraft Failures Due to Tribological Problems
NASA Technical Reports Server (NTRS)
Fusaro, Robert L.
2001-01-01
Many mechanical failures that occur on spacecraft are caused by tribological problems. This publication presents a study that was conducted by the author on various preventatives, analyses, controls and tests (PACTs) that could be used to prevent spacecraft mechanical system failure. A matrix is presented in the paper that plots tribology failure modes versus various PACTs that should be performed before a spacecraft is launched in order to insure success. A strawman matrix was constructed by the author and then was sent out to industry and government spacecraft designers, scientists and builders of spacecraft for their input. The final matrix is the result of their input. In addition to the matrix, this publication describes the various PACTs that can be performed and some fundamental knowledge on the correct usage of lubricants for spacecraft applications. Even though the work was done specifically to prevent spacecraft failures the basic methodology can be applied to other mechanical system areas.
1993-04-15
Czyryca from the Naval Surface Warfare Center gave a Plenary Aodress on Lessons Learned in Metallurgical Failure Analyses of Naval Machinery. The...processing methods take many years to implement, because of the large capital investments and the learning process involved, we feel confident that they will...signals experienced by the self. Filters are an indistinguishable part of the self. As we learn about the causes of our failures, and see that we can
1994-04-21
stress rupture fractured specimens (a) as- ROC’ed, (b) beat treated by schedule 2. (a) (b) (c) (d) Figure 6: SEM fractographs of super-a, tensile... beat 195 - - . -i The microstructure in the weld region and at the fatigue failures was studied and related o the observed failures.Fati ue data are...inspector also can use one or two audio output channels for either mono or stereo ( binaural ) presentation of the aural information. Auralkatlon of
Huang, Chung-Chi; Huang, Chung-Lin; Liu, Hsiao-Man
2015-01-01
In recent years, it is quite important to develop a customized system which can enhance physical fitness and health for people. And the system reliability is more important. In the paper, a fool-proofing design and crisis management for customized physical fitness and healthcare system is proposed. It is designed to prevent the failure of the various mechanisms of customized physical fitness and healthcare system, including records, surveillance, assessments, predictions, diagnosis, prescription, and scheduling. It is separated into (1) fool-proofing design module (2) crisis management module. The fool-proofing indexes are set to prevent the failure of the various mechanisms. The states of the various mechanisms are managed by the auto-checked fool-proofing indexes. If mistakes prevention was fail, we have to execute the crisis management for stopping harmful results. The crisis management will find the error level and response the solution by using fuzzy method. By the experiments, we can find the advantages of the fool-proofing design and crisis management for customized physical fitness and healthcare system. And it is effective to prevent the failure of the various mechanisms of intelligent customized physical fitness and healthcare system.
NASA Astrophysics Data System (ADS)
Aghababaei, Sajjad; Saeedi, Gholamreza; Jalalifar, Hossein
2016-05-01
The floor failure at longwall face decreases productivity and safety, increases operation costs, and causes other serious problems. In Parvadeh-I coal mine, the timber is used to prevent the puncture of powered support base into the floor. In this paper, a rock engineering system (RES)-based model is presented to evaluate the risk of floor failure mechanisms at the longwall face of E 2 and W 1 panels. The presented model is used to determine the most probable floor failure mechanism, effective factors, damaged regions and remedial actions. From the analyzed results, it is found that soft floor failure is dominant in the floor failure mechanism at Parvadeh-I coal mine. The average of vulnerability index (VI) for soft, buckling and compressive floor failure mechanisms was estimated equal to 52, 43 and 30 for both panels, respectively. By determining the critical VI for soft floor failure mechanism equal to 54, the percentage of regions with VIs beyond the critical VI in E 2 and W 1 panels is equal to 65.5 and 30, respectively. The percentage of damaged regions showed that the excess amount of used timber to prevent the puncture of weak floor below the powered support base is equal to 4,180,739 kg. RES outputs and analyzed results showed that setting and yielding load of powered supports, length of face, existent water at face, geometry of powered supports, changing the cutting pattern at longwall face and limiting the panels to damaged regions with supercritical VIs could be considered to control the soft floor failure in this mine. The results of this research could be used as a useful tool to identify the damaged regions prior to mining operation at longwall panel for the same conditions.
Lox/Gox related failures during Space Shuttle Main Engine development
NASA Technical Reports Server (NTRS)
Cataldo, C. E.
1981-01-01
Specific rocket engine hardware and test facility system failures are described which were caused by high pressure liquid and/or gaseous oxygen reactions. The failures were encountered during the development and testing of the space shuttle main engine. Failure mechanisms are discussed as well as corrective actions taken to prevent or reduce the potential of future failures.
Pyrotechnic system failures: Causes and prevention
NASA Technical Reports Server (NTRS)
Bement, Laurence J.
1988-01-01
Although pyrotechnics have successfully accomplished many critical mechanical spacecraft functions, such as ignition, severance, jettisoning and valving (excluding propulsion), failures continue to occur. Provided is a listing of 84 failures of pyrotechnic hardware with completed design over a 23-year period, compiled informally by experts from every NASA Center, as well as the Air Force Space Division and the Naval Surface Warfare Center. Analyses are presented as to when and where these failures occurred, their technical source or cause, followed by the reasons why and how these kinds of failures persist. The major contributor is a fundamental lack of understanding of the functional mechanisms of pyrotechnic devices and systems, followed by not recognizing pyrotechnics as an engineering technology, insufficient manpower with hands-on experience, too few test facilities, and inadequate guidelines and specifications for design, development, qualification and acceptance. Recommendations are made on both a managerial and technical basis to prevent failures, increase reliability, improve existing and future designs, and develop the technology to meet future requirements.
1976-09-01
testing evaluation and production process development . This coated microspherical fuel particle has been successfully developed over a period of...this reliable concept began with attempts to blend ceramic (oxide or carbide) fuel powders into a graphite matrix in the early concepts of ROVER, HTGR ...lubricants. An ongoing program at the Naval Air Development Center is investigating how some parameters affect corro- sion between solid film
NASA Technical Reports Server (NTRS)
Shives, T. R.; Willard, W. A.
1979-01-01
The design and application of advanced composites is discussed with emphasis on aerospace, aircraft, automotive, marine, and industrial applications. Failure modes in advanced composites are also discussed.
Failure mechanism of THz GaAs photoconductive antenna
NASA Astrophysics Data System (ADS)
Qadri, Syed B.; Wu, Dong H.; Graber, Benjamin D.; Mahadik, Nadeemullah A.; Garzarella, Anthony
2012-07-01
We investigated the failure mechanism of THz GaAs photoconductive antenna using high resolution x-ray diffraction topography. From these studies, it was found that grain boundaries are formed during the high frequency device operation. This results in the segregation of gold at the boundaries causing electromigration of the metal between the gold micro-strips. This disrupts the photocurrents from being produced by femtosecond laser thus preventing terahertz beam generation from the photoconductive antennae leading to device failure.
1990-01-01
become a sort of standard for the presence of microplasticity . What we have to realize is that both cleavage and MVC are larger scaled results of finer...34 Paper presented at Naval Sea Systems Command Magnetic Bearing Forum, Washington, D. C., July 1989. 11. Humphris, R. R., R. D. Kelm, D. W. Lewis and P. E...increasingly stringent. Several studies have pointed to the value of this concept. The revolution at sea SOCS study identified the need for and benefits of
Valve system incorporating single failure protection logic
Ryan, Rodger; Timmerman, Walter J. H.
1980-01-01
A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.
Zhang, Xiaowei; Sahraei, Elham; Wang, Kai
2016-01-01
Separator integrity is an important factor in preventing internal short circuit in lithium-ion batteries. Local penetration tests (nail or conical punch) often produce presumably sporadic results, where in exactly similar cell and test set-ups one cell goes to thermal runaway while the other shows minimal reactions. We conducted an experimental study of the separators under mechanical loading, and discovered two distinct deformation and failure mechanisms, which could explain the difference in short circuit characteristics of otherwise similar tests. Additionally, by investigation of failure modes, we provided a hypothesis about the process of formation of local “soft short circuits” in cells with undetectable failure. Finally, we proposed a criterion for predicting onset of soft short from experimental data. PMID:27581185
NASA Technical Reports Server (NTRS)
Shives, T. R. (Editor); Willard, W. A. (Editor)
1981-01-01
The contribution of failure detection, diagnosis and prognosis to the energy challenge is discussed. Areas of special emphasis included energy management, techniques for failure detection in energy related systems, improved prognostic techniques for energy related systems and opportunities for detection, diagnosis and prognosis in the energy field.
1991-04-04
solution to this immediate problem and, as the technology developed, opened doors to applied tribology for advanced maintenance through Mechanical Systems...Integrity Management. The development of other technologies as well enhanced Spectron’s capability, but it was the major advances in electronics and...strain gages will also be studied. The results of this program will provide a basis for future work in the area of advanced sensor technology . ONCUBSIONS
Failure mechanisms of laminates transversely loaded by bolt push-through
NASA Technical Reports Server (NTRS)
Waters, W. A., Jr.; Williams, J. G.
1985-01-01
Stiffened composite panels proposed for fuselage and wing design utilize a variety of stiffener-to-skin attachment concepts including mechanical fasteners. The attachment concept is an important factor influencing the panel's strength and can govern its performance following local damage. Mechanical fasteners can be an effective method for preventing stiffener-skin separation. One potential failure mode for bolted panels occurs when the bolts pull through the stiffener attachment flange or skin. The resulting loss of support by the skin to the stiffener and by the stiffener to the skin can result in local buckling and subsequent panel collapse. The characteristic failure modes associated with bolt push-through failure are described and the results of a parametric study of the effects that different material systems, boundary conditions, and laminates have on the forces and displacements required to cause damage and bolt pushthrough failure are presented.
Hypertension and counter-hypertension mechanisms in giraffes.
Zhang, Qiong Gus
2006-03-01
The giraffe is unique as its head is 2500-3000 millimeters above its heart, thus the giraffe's heart must pump hard enough to overcome the huge hydrostatic pressure generated by the tall column of blood in its neck in order to provide its head with sufficient nutrients and oxygen. Giraffes therefore have exceptionally high blood pressure (hypertension) by human standards. Interestingly, the "unnaturally" high blood pressure in giraffes does not culminate in severe vascular lesions, nor does it lead to heart and kidney failure, whereas in humans, the same blood pressure is exceedingly dangerous and will cause severe vascular damage. Intrinsically, natural selection likely has provided an important protective mechanism, because hypertension develops as soon as the giraffe stands up and erects its neck immediately after birth. Therefore, those individual giraffes who did not tolerate the burden of hypertension presumably developed acute heart failure and renal failure, not surviving to reproductive age. The genes and genotypes of animals that did not survive are thus predicted to have been gradually eliminated from the gene pool by natural selection. By the same process, genes that protect against hypertensive damage would be preserved and inherited from generation to generation. Some unique ingredients of the giraffe's diet may also provide an extrinsic mechanism for the prevention of hypertension and the prevention of fatal end-stage organ damage. The fascinating nature of the protective mechanisms in giraffes may provide a conceptual framework for further experimental investigations into mechanisms as well as prevention and treatment of human hypertension and cardiovascular disease.
2015-01-01
Ground control research in underground coal mines has been ongoing for over 50 years. One of the most problematic issues in underground coal mines is roof failures associated with weak shale. This paper will present a historical narrative on the research the National Institute for Occupational Safety and Health has conducted in relation to rock mechanics and shale. This paper begins by first discussing how shale is classified in relation to coal mining. Characterizing and planning for weak roof sequences is an important step in developing an engineering solution to prevent roof failures. Next, the failure mechanics associated with the weak characteristics of shale will be discussed. Understanding these failure mechanics also aids in applying the correct engineering solutions. The various solutions that have been implemented in the underground coal mining industry to control the different modes of failure will be summarized. Finally, a discussion on current and future research relating to rock mechanics and shale is presented. The overall goal of the paper is to share the collective ground control experience of controlling roof structures dominated by shale rock in underground coal mining. PMID:26549926
Murphy, M M
2016-02-01
Ground control research in underground coal mines has been ongoing for over 50 years. One of the most problematic issues in underground coal mines is roof failures associated with weak shale. This paper will present a historical narrative on the research the National Institute for Occupational Safety and Health has conducted in relation to rock mechanics and shale. This paper begins by first discussing how shale is classified in relation to coal mining. Characterizing and planning for weak roof sequences is an important step in developing an engineering solution to prevent roof failures. Next, the failure mechanics associated with the weak characteristics of shale will be discussed. Understanding these failure mechanics also aids in applying the correct engineering solutions. The various solutions that have been implemented in the underground coal mining industry to control the different modes of failure will be summarized. Finally, a discussion on current and future research relating to rock mechanics and shale is presented. The overall goal of the paper is to share the collective ground control experience of controlling roof structures dominated by shale rock in underground coal mining.
NASA Astrophysics Data System (ADS)
Murphy, M. M.
2016-02-01
Ground control research in underground coal mines has been ongoing for over 50 years. One of the most problematic issues in underground coal mines is roof failures associated with weak shale. This paper will present a historical narrative on the research the National Institute for Occupational Safety and Health has conducted in relation to rock mechanics and shale. This paper begins by first discussing how shale is classified in relation to coal mining. Characterizing and planning for weak roof sequences is an important step in developing an engineering solution to prevent roof failures. Next, the failure mechanics associated with the weak characteristics of shale will be discussed. Understanding these failure mechanics also aids in applying the correct engineering solutions. The various solutions that have been implemented in the underground coal mining industry to control the different modes of failure will be summarized. Finally, a discussion on current and future research relating to rock mechanics and shale is presented. The overall goal of the paper is to share the collective ground control experience of controlling roof structures dominated by shale rock in underground coal mining.
Disease prevention policy under Medicare: a historical and political analysis.
Schauffler, H H
1993-01-01
I review the history and politics of Medicare disease prevention policy and identify factors associated with the success or failure of legislative initiatives to add preventive services benefits to Medicare. Between 1965 and 1990, 453 bills for Medicare preventive services were introduced in the U.S. Congress, but not until 1980, after 350 bills had failed, was the first preventive service added to the Medicare program. Medicare currently pays for only four of the 44 preventive services recommended for the elderly by the U.S. Preventive Services Task Force (pneumococcal and hepatitis B vaccinations, Pap smears, and mammography). In addition, Congress has funded demonstration programs for the influenza vaccine and comprehensive preventive services. The preventive services added to Medicare reflect the bias of the biomedical model toward screening and immunizations. Counseling services have received the least legislative attention. Factors associated with successful enactment include single-benefit bills, incorporation into budget-deficit reduction legislation, documented evidence of cost-effectiveness, public hearings, sponsorship by chairs of key congressional committees, and persistent congressional leadership. Factors associated with failure include lack of support from Medicare beneficiaries, lack of professional support, impact on total Medicare expenditures, disagreement over or failure to address payment and financing mechanisms, and competing congressional priorities.
Respiratory Compromise as a New Paradigm for the Care of Vulnerable Hospitalized Patients.
Morris, Timothy A; Gay, Peter C; MacIntyre, Neil R; Hess, Dean R; Hanneman, Sandra K; Lamberti, James P; Doherty, Dennis E; Chang, Lydia; Seckel, Maureen A
2017-04-01
Acute respiratory compromise describes a deterioration in respiratory function with a high likelihood of rapid progression to respiratory failure and death. Identifying patients at risk for respiratory compromise coupled with monitoring of patients who have developed respiratory compromise might allow earlier interventions to prevent or mitigate further decompensation. The National Association for the Medical Direction of Respiratory Care (NAMDRC) organized a workshop meeting with representation from many national societies to address the unmet needs of respiratory compromise from a clinical practice perspective. Respiratory compromise may arise de novo or may complicate preexisting lung disease. The group identified distinct subsets of respiratory compromise that present similar opportunities for early detection and useful intervention to prevent respiratory failure. The subtypes were characterized by the pathophysiological mechanisms they had in common: impaired control of breathing, impaired airway protection, parenchymal lung disease, increased airway resistance, hydrostatic pulmonary edema, and right-ventricular failure. Classification of acutely ill respiratory patients into one or more of these categories may help in selecting the screening and monitoring strategies that are most appropriate for the patient's particular pathophysiology. Standardized screening and monitoring practices for patients with similar mechanisms of deterioration may enhance the ability to predict respiratory failure early and prevent its occurrence. Copyright © 2017 by Daedalus Enterprises.
Insights into Metabolic Mechanisms Underlying Folate-Responsive Neural Tube Defects: A Minireview
Beaudin, Anna E.; Stover, Patrick J.
2015-01-01
Neural tube defects (NTDs), including anencephaly and spina bifida, arise from the failure of neurulation during early embryonic development. Neural tube defects are common birth defects with a heterogenous and multifactorial etiology with interacting genetic and environmental risk factors. Although the mechanisms resulting in failure of neural tube closure are unknown, up to 70% of NTDs can be prevented by maternal folic acid supplementation. However, the metabolic mechanisms underlying the association between folic acid and NTD pathogenesis have not been identified. This review summarizes our current understanding of the mechanisms by which impairments in folate metabolism might ultimately lead to failure of neural tube closure, with an emphasis on untangling the relative contributions of nutritional deficiency and genetic risk factors to NTD pathogenesis. PMID:19180567
Early laparotomy wound failure as the mechanism for incisional hernia formation
Xing, Liyu; Culbertson, Eric J.; Wen, Yuan; Franz, Michael G.
2015-01-01
Background Incisional hernia is the most common complication of abdominal surgery leading to reoperation. In the United States, 200,000 incisional hernia repairs are performed annually, often with significant morbidity. Obesity is increasing the risk of laparotomy wound failure. Methods We used a validated animal model of incisional hernia formation. We intentionally induced laparotomy wound failure in otherwise normal adult, male Sprague-Dawley rats. Radio-opaque, metal surgical clips served as markers for the use of x-ray images to follow the progress of laparotomy wound failure. We confirmed radiographic findings of the time course for mechanical laparotomy wound failure by necropsy. Results Noninvasive radiographic imaging predicts early laparotomy wound failure and incisional hernia formation. We confirmed both transverse and craniocaudad migration of radio-opaque markers at necropsy after 28 d that was uniformly associated with the clinical development of incisional hernias. Conclusions Early laparotomy wound failure is a primary mechanism for incisional hernia formation. A noninvasive radiographic method for studying laparotomy wound healing may help design clinical trials to prevent and treat this common general surgical complication. PMID:23036516
Levee reliability analyses for various flood return periods - a case study in southern Taiwan
NASA Astrophysics Data System (ADS)
Huang, W.-C.; Yu, H.-W.; Weng, M.-C.
2015-04-01
In recent years, heavy rainfall conditions have caused disasters around the world. To prevent losses by floods, levees have often been constructed in inundation-prone areas. This study performed reliability analyses for the Chiuliao First Levee in southern Taiwan. The failure-related parameters were the water level, the scouring depth, and the in situ friction angle. Three major failure mechanisms were considered: the slope sliding failure of the levee and the sliding and overturning failures of the retaining wall. When the variability of the in situ friction angle and the scouring depth are considered for various flood return periods, the variations of the factor of safety for the different failure mechanisms show that the retaining wall sliding and overturning failures are more sensitive to the change of the friction angle. When the flood return period is greater than 2 years, the levee could fail with slope sliding for all values of the water level difference. The results of levee stability analysis considering the variability of different parameters could aid engineers in designing the levee cross sections, especially with potential failure mechanisms in mind.
NASA Technical Reports Server (NTRS)
Westrup, R. W.
1971-01-01
The application of general design approaches for preventing failures due to repeated load cycles is briefly discussed. Program objective, mission requirements, and structural design criteria are summarized. Discrete structural elements and associated sections were selected for detailed strength, fatigue, and fracture mechanics investigations.
Quantitative ultrasonic evaluation of mechanical properties of engineering materials
NASA Technical Reports Server (NTRS)
Vary, A.
1978-01-01
Current progress in the application of ultrasonic techniques to nondestructive measurement of mechanical strength properties of engineering materials is reviewed. Even where conventional NDE techniques have shown that a part is free of overt defects, advanced NDE techniques should be available to confirm the material properties assumed in the part's design. There are many instances where metallic, composite, or ceramic parts may be free of critical defects while still being susceptible to failure under design loads due to inadequate or degraded mechanical strength. This must be considered in any failure prevention scheme that relies on fracture analysis. This review will discuss the availability of ultrasonic methods that can be applied to actual parts to assess their potential susceptibility to failure under design conditions.
Levee reliability analyses for various flood return periods - a case study in Southern Taiwan
NASA Astrophysics Data System (ADS)
Huang, W.-C.; Yu, H.-W.; Weng, M.-C.
2015-01-01
In recent years, heavy rainfall conditions have caused damages around the world. To prevent damages by floods, levees have often been constructed in prone-to-inundation areas. This study performed reliability analyses for the Chiuliao 1st Levee located in southern Taiwan. The failure-related parameters were the water level, the scouring depth, and the in-situ friction angle. Three major failure mechanisms were considered, including the slope sliding failure of the levee, and the sliding and overturning failures of the retaining wall. When the variabilities of the in-situ friction angle and the scouring depth are considered for various flood return periods, the variations of the factor of safety (FS) for the different failure mechanisms show that the retaining wall sliding and overturning failures are more sensitive to the variability of the friction angle. When the flood return period is greater than 2 years, the levee can undergo slope sliding failure for all values of the water level difference. The results for levee stability analysis considering the variability of different parameters could assist engineers in designing the levee cross sections, especially with potential failure mechanisms in mind.
Single-event burnout of n-p-n bipolar-junction transistors in hybrid DC/DC converters
NASA Astrophysics Data System (ADS)
Warren, K.; Roth, D.; Kinnison, J.; Pappalardo, R.
2002-12-01
Single-event-induced failure of the Lambda Advanced Analog AMF2805S DC/DC Converter has been traced to burnout of an n-p-n transistor in the MOSFET drive stage. The failures were observed during testing while in inhibit mode only. Modifications to prevent burnout of the drive stage were successfully employed. A discussion of the failure mechanism and consequences for DC/DC converter testing are presented.
Noninvasive Mechanical Ventilation in Acute Ventilatory Failure: Rationale and Current Applications.
Esquinas, Antonio M; Benhamou, Maly Oron; Glossop, Alastair J; Mina, Bushra
2017-12-01
Noninvasive ventilation plays a pivotal role in acute ventilator failure and has been shown, in certain disease processes such as acute exacerbation of chronic obstructive pulmonary disease, to prevent and shorten the duration of invasive mechanical ventilation, reducing the risks and complications associated with it. The application of noninvasive ventilation is relatively simple and well tolerated by patients and in the right setting can change the course of their illness. Copyright © 2017 Elsevier Inc. All rights reserved.
Controlling stress corrosion cracking in mechanism components of ground support equipment
NASA Technical Reports Server (NTRS)
Majid, W. A.
1988-01-01
The selection of materials for mechanism components used in ground support equipment so that failures resulting from stress corrosion cracking will be prevented is described. A general criteria to be used in designing for resistance to stress corrosion cracking is also provided. Stress corrosion can be defined as combined action of sustained tensile stress and corrosion to cause premature failure of materials. Various aluminum, steels, nickel, titanium and copper alloys, and tempers and corrosive environment are evaluated for stress corrosion cracking.
Mechanisms of Post-Infarct Left Ventricular Remodeling
French, Brent A.; Kramer, Christopher M.
2008-01-01
Heart failure secondary to myocardial infarction (MI) remains a major source of morbidity and mortality. Long-term outcome after MI can be largely be defined in terms of its impact on the size and shape of the left ventricle (i.e., LV remodeling). Three major mechanisms contribute to LV remodeling: 1) early infarct expansion, 2) subsequent infarct extension into adjacent noninfarcted myocardium, and 3) late hypertrophy in the remote LV. Future developments in preventing post-MI heart failure will depend not only on identifying drugs targeting each of these individual mechanisms, but also on diagnostic techniques capable of assessing efficacy against each mechanism. PMID:18690295
Cardiac Cachexia: Perspectives for Prevention and Treatment.
Okoshi, Marina Politi; Capalbo, Rafael Verardino; Romeiro, Fernando G; Okoshi, Katashi
2017-01-01
Cachexia is a prevalent pathological condition associated with chronic heart failure. Its occurrence predicts increased morbidity and mortality independent of important clinical variables such as age, ventricular function, or heart failure functional class. The clinical consequences of cachexia are dependent on both weight loss and systemic inflammation, which accompany cachexia development. Skeletal muscle wasting is an important component of cachexia; it often precedes cachexia development and predicts poor outcome in heart failure. Cachexia clinically affects several organs and systems. It is a multifactorial condition where underlying pathophysiological mechanisms are not completely understood making it difficult to develop specific prevention and treatment therapies. Preventive strategies have largely focused on muscle mass preservation. Different treatment options have been described, mostly in small clinical studies or experimental settings. These include nutritional support, neurohormonal blockade, reducing intestinal bacterial translocation, anemia and iron deficiency treatment, appetite stimulants, immunomodulatory agents, anabolic hormones, and physical exercise regimens. Currently, nonpharmacological therapy such as nutritional support and physical exercise are considered central to cachexia prevention and treatment.
Jordan, Jens; Toplak, Hermann; Grassi, Guido; Yumuk, Volkan; Kotsis, Vasilios; Engeli, Stefan; Cuspidi, Cesare; Nilsson, Peter M; Finer, Nick; Doehner, Wolfram
2016-09-01
Obese individuals are more likely to develop heart failure. Yet, once heart failure is established, the impact of overweight and obesity on prognosis and survival is unclear. The purpose of this joint scientific statement of the European Association for the Study of Obesity and the European Society of Hypertension is to provide an overview on the current scientific literature on obesity and heart failure in terms of prognosis, mechanisms, and clinical management implications. Moreover, the document identifies open questions that ought to be addressed. The need for more tailored weight management recommendations in heart failure will be emphasized and, in line with the emerging evidence, aims to distinguish between primary disease and secondary outcome prevention. In the primary prevention of heart failure, it appears prudent advising obese individuals to lose or achieve a healthy body weight, especially in those with risk factors such as hypertension or type 2 diabetes. However, there is no evidence from clinical trials to guide weight management in overweight or obese patients with established heart failure. Prospective clinical trials are strongly encouraged.
Aessopos, Athanassios; Berdoukas, Vasilios; Tsironi, Maria
2008-01-01
Cardiac disease remains the major cause of death in thalassaemia major. This review deals with the mechanisms involved in heart failure development, the peculiar clinical presentation of congestive heart failure and provides guidelines for diagnosis and management of the acute phase of cardiac failure. It emphasizes the need for intensive medical – cardiac care and aggressive iron chelating management as, with such approaches, today, the patients outcomes can be favourable in the long term. It covers advances in the assessment of cardiac iron overload with the use of magnetic resonance imaging and makes recommendations for preventing the onset of cardiac problems by tailoring iron chelation therapy appropriate to the degree of cardiac iron loading found. PMID:18081719
van der Beek, Allard J; Dennerlein, Jack T; Huysmans, Maaike A; Mathiassen, Svend Erik; Burdorf, Alex; van Mechelen, Willem; van Dieën, Jaap H; Frings-Dresen, Monique Hw; Holtermann, Andreas; Janwantanakul, Prawit; van der Molen, Henk F; Rempel, David; Straker, Leon; Walker-Bone, Karen; Coenen, Pieter
2017-11-01
Objectives Work-related musculoskeletal disorders (MSD) are highly prevalent and put a large burden on (working) society. Primary prevention of work-related MSD focuses often on physical risk factors (such as manual lifting and awkward postures) but has not been too successful in reducing the MSD burden. This may partly be caused by insufficient knowledge of etiological mechanisms and/or a lack of adequately feasible interventions (theory failure and program failure, respectively), possibly due to limited integration of research disciplines. A research framework could link research disciplines thereby strengthening the development and implementation of preventive interventions. Our objective was to define and describe such a framework for multi-disciplinary research on work-related MSD prevention. Methods We described a framework for MSD prevention research, partly based on frameworks from other research fields (ie, sports injury prevention and public health). Results The framework is composed of a repeated sequence of six steps comprising the assessment of (i) incidence and severity of MSD, (ii) risk factors for MSD, and (iii) underlying mechanisms; and the (iv) development, (v) evaluation, and (vi) implementation of preventive intervention(s). Conclusions In the present framework for optimal work-related MSD prevention, research disciplines are linked. This framework can thereby help to improve theories and strengthen the development and implementation of prevention strategies for work-related MSD.
[Contrast-induced acute kidney injury in cardiology].
Genovesi, Eugenio; Romanello, Mattia; De Caterina, Raffaele
2016-12-01
The intravascular administration of contrast media is an important tool in cardiovascular imaging, especially in percutaneous coronary interventions (PCI). Owing to the widespread use of these procedures, contrast-induced acute kidney injury (CI-AKI) has become one of the most common types of acute renal failures. CI-AKI is mainly mediated by mechanisms of oxidative damage, and its onset is associated with prolonged hospitalization and significant morbidity and mortality. Preexisting chronic kidney disease, diabetes, age, heart failure, and characteristics related to the procedure (primary or elective PCI, type and amount of contrast medium) are the most important risk factors for the development of post-PCI CI-AKI.For this serious complication, prevention is more important than treatment, and various preventive measures have been widely tested in recent years. However, none of the strategies so far evaluated, with the exception of pre-procedural hydration with isotonic saline, has been shown to effectively prevent CI-AKI in randomized trials in large populations. In this review, we discuss the incidence, risk factors, main pathogenetic mechanisms and current strategies for the prevention of CI-AKI.
Fan, Ruoxun; Liu, Jie; Jia, Zhengbin; Deng, Ying; Liu, Jun
2018-01-01
Macro-level failure in bone structure could be diagnosed by pain or physical examination. However, diagnosing tissue-level failure in a timely manner is challenging due to the difficulty in observing the interior mechanical environment of bone tissue. Because most fractures begin with tissue-level failure in bone tissue caused by continually applied loading, people attempt to monitor the tissue-level failure of bone and provide corresponding measures to prevent fracture. Many tissue-level mechanical parameters of bone could be predicted or measured; however, the value of the parameter may vary among different specimens belonging to a kind of bone structure even at the same age and anatomical site. These variations cause difficulty in representing tissue-level bone failure. Therefore, determining an appropriate tissue-level failure evaluation standard is necessary to represent tissue-level bone failure. In this study, the yield and failure processes of rat femoral cortical bones were primarily simulated through a hybrid computational-experimental method. Subsequently, the tissue-level strains and the ratio between tissue-level failure and yield strains in cortical bones were predicted. The results indicated that certain differences existed in tissue-level strains; however, slight variations in the ratio were observed among different cortical bones. Therefore, the ratio between tissue-level failure and yield strains for a kind of bone structure could be determined. This ratio may then be regarded as an appropriate tissue-level failure evaluation standard to represent the mechanical status of bone tissue.
Finite Element Creep-Fatigue Analysis of a Welded Furnace Roll for Identifying Failure Root Cause
NASA Astrophysics Data System (ADS)
Yang, Y. P.; Mohr, W. C.
2015-11-01
Creep-fatigue induced failures are often observed in engineering components operating under high temperature and cyclic loading. Understanding the creep-fatigue damage process and identifying failure root cause are very important for preventing such failures and improving the lifetime of engineering components. Finite element analyses including a heat transfer analysis and a creep-fatigue analysis were conducted to model the cyclic thermal and mechanical process of a furnace roll in a continuous hot-dip coating line. Typically, the roll has a short life, <1 year, which has been a problem for a long time. The failure occurred in the weld joining an end bell to a roll shell and resulted in the complete 360° separation of the end bell from the roll shell. The heat transfer analysis was conducted to predict the temperature history of the roll by modeling heat convection from hot air inside the furnace. The creep-fatigue analysis was performed by inputting the predicted temperature history and applying mechanical loads. The analysis results showed that the failure was resulted from a creep-fatigue mechanism rather than a creep mechanism. The difference of material properties between the filler metal and the base metal is the root cause for the roll failure, which induces higher creep strain and stress in the interface between the weld and the HAZ.
Multi-physics modeling of multifunctional composite materials for damage detection
NASA Astrophysics Data System (ADS)
Sujidkul, Thanyawalai
This study presents a modeling of multifunction composite materials for damage detection with its verification and validation to mechanical behavior predictions of Carbon Fibre Reinforced Polymer composites (CFRPs), CFRPs laminated composites, and woven SiC/SiC matrix composites that are subjected to fracture damage. Advantages of those materials are low cost, low density, high strength-to-weight ratio, and comparable specific tensile properties, the special of SiC/SiC is good environmental stability at high temperature. Resulting in, the composite has been used for many important structures such as helicopter rotors, aerojet engines, gas turbines, hot control surfaces, sporting goods, and windmill blades. Damage or material defect detection in a mechanical component can provide vital information for the prediction of remaining useful life, which will result in the prevention of catastrophic failures. Thus the understanding of the mechanical behavior have been challenge to the prevent damage and failure of composites in different scales. The damage detection methods in composites have been investigated widely in recent years. Non-destructive techniques are the traditional methods to detect the damage such as X-ray, acoustic emission and thermography. However, due to the invisible damage in composite can be occurred, to prevent the failure in composites. The developments of damage detection methods have been considered. Due to carbon fibers are conductive materials, in resulting CFRPs can be self-sensing to detect damage. As is well known, the electrical resistance has been shown to be a sensitive measure of internal damage, and also this work study in thermal resistance can detect damage in composites. However, there is a few number of different micromechanical modeling schemes has been proposed in the published literature for various types of composites. This works will provide with a numerical, analytical, and theoretical failure models in different damages to predict the mechanical damage behavior with electrical properties and thermal properties.
Introducing a New Guided Design into the Classroom.
ERIC Educational Resources Information Center
Allen, Charles W.
Based on a workshop presented by Charles Wales, a guided design project was developed for a junior mechanical design class at California State University-Chico. This course involves lectures on the design process and an extension of the basic mechanics of materials concepts, particularly as related to design and prevention of failure. The…
Twiddler's syndrome in spinal cord stimulation.
Al-Mahfoudh, Rafid; Chan, Yuen; Chong, Hsu Pheen; Farah, Jibril Osman
2016-01-01
The aims are to present a case series of Twiddler's syndrome in spinal cord stimulators with analysis of the possible mechanism of this syndrome and discuss how this phenomenon can be prevented. Data were collected retrospectively between 2007 and 2013 for all patients presenting with failure of spinal cord stimulators. The diagnostic criterion for Twiddler's syndrome is radiological evidence of twisting of wires in the presence of failure of spinal cord stimulation. Our unit implants on average 110 spinal cord stimulators a year. Over the 5-year study period, all consecutive cases of spinal cord stimulation failure were studied. Three patients with Twiddler's syndrome were identified. Presentation ranged from 4 to 228 weeks after implantation. Imaging revealed repeated rotations and twisting of the wires of the spinal cord stimulators leading to hardware failure. To the best of our knowledge this is the first reported series of Twiddler's syndrome with implantable pulse generators (IPGs) for spinal cord stimulation. Hardware failure is not uncommon in spinal cord stimulation. Awareness and identification of Twiddler's syndrome may help prevent its occurrence and further revisions. This may be achieved by implanting the IPG in the lumbar region subcutaneously above the belt line. Psychological intervention may have a preventative role for those who are deemed at high risk of Twiddler's syndrome from initial psychological screening.
Plasma membrane disruption: repair, prevention, adaptation
NASA Technical Reports Server (NTRS)
McNeil, Paul L.; Steinhardt, Richard A.
2003-01-01
Many metazoan cells inhabit mechanically stressful environments and, consequently, their plasma membranes are frequently disrupted. Survival requires that the cell rapidly repair or reseal the disruption. Rapid resealing is an active and complex structural modification that employs endomembrane as its primary building block, and cytoskeletal and membrane fusion proteins as its catalysts. Endomembrane is delivered to the damaged plasma membrane through exocytosis, a ubiquitous Ca2+-triggered response to disruption. Tissue and cell level architecture prevent disruptions from occurring, either by shielding cells from damaging levels of force, or, when this is not possible, by promoting safe force transmission through the plasma membrane via protein-based cables and linkages. Prevention of disruption also can be a dynamic cell or tissue level adaptation triggered when a damaging level of mechanical stress is imposed. Disease results from failure of either the preventive or resealing mechanisms.
Clinical challenges in mechanical ventilation.
Goligher, Ewan C; Ferguson, Niall D; Brochard, Laurent J
2016-04-30
Mechanical ventilation supports gas exchange and alleviates the work of breathing when the respiratory muscles are overwhelmed by an acute pulmonary or systemic insult. Although mechanical ventilation is not generally considered a treatment for acute respiratory failure per se, ventilator management warrants close attention because inappropriate ventilation can result in injury to the lungs or respiratory muscles and worsen morbidity and mortality. Key clinical challenges include averting intubation in patients with respiratory failure with non-invasive techniques for respiratory support; delivering lung-protective ventilation to prevent ventilator-induced lung injury; maintaining adequate gas exchange in severely hypoxaemic patients; avoiding the development of ventilator-induced diaphragm dysfunction; and diagnosing and treating the many pathophysiological mechanisms that impair liberation from mechanical ventilation. Personalisation of mechanical ventilation based on individual physiological characteristics and responses to therapy can further improve outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kim, Bo-Hyun; Walton, Gabriel; Larson, Mark K.; Berry, Steve
2018-01-01
Characterizing a coal from an engineering perspective for design of mining excavations is critical in order to prevent fatalities, as underground coal mines are often developed in highly stressed ground conditions. Coal pillar bursts involve the sudden expulsion of coal and rock into the mine opening. These events occur when relatively high stresses in a coal pillar, left for support in underground workings, exceed the pillar’s load capacity causing the pillar to rupture without warning. This process may be influenced by cleating, which is a type of joint system that can be found in coal rock masses. As such, it is important to consider the anisotropy of coal mechanical behavior. Additionally, if coal is expected to fail in a brittle manner, then behavior changes, such as the transition from extensional to shear failure, have to be considered and reflected in the adopted failure criteria. It must be anticipated that a different failure mechanism occurs as the confinement level increases and conditions for tensile failure are prevented or strongly diminished. The anisotropy and confinement dependency of coal behavior previously mentioned merit extensive investigation. In this study, a total of 84 samples obtained from a Utah coal mine were investigated by conducting both unconfined and triaxial compressive tests. The results showed that the confining pressure dictated not only the peak compressive strength but also the brittleness as a function of the major to the minor principal stress ratio. Additionally, an s-shaped brittle failure criterion was fitted to the results, showing the development of confinement-dependent strength. Moreover, these mechanical characteristics were found to be strongly anisotropic, which was associated with the orientation of the cleats relative to the loading direction. PMID:29780272
Effect of Preconditioning and Soldering on Failures of Chip Tantalum Capacitors
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander A.
2014-01-01
Soldering of molded case tantalum capacitors can result in damage to Ta205 dielectric and first turn-on failures due to thermo-mechanical stresses caused by CTE mismatch between materials used in the capacitors. It is also known that presence of moisture might cause damage to plastic cases due to the pop-corning effect. However, there are only scarce literature data on the effect of moisture content on the probability of post-soldering electrical failures. In this work, that is based on a case history, different groups of similar types of CWR tantalum capacitors from two lots were prepared for soldering by bake, moisture saturation, and longterm storage at room conditions. Results of the testing showed that both factors: initial quality of the lot, and preconditioning affect the probability of failures. Baking before soldering was shown to be effective to prevent failures even in lots susceptible to pop-corning damage. Mechanism of failures is discussed and recommendations for pre-soldering bake are suggested based on analysis of moisture characteristics of materials used in the capacitors' design.
High-Temperature Graphitization Failure of Primary Superheater Tube
NASA Astrophysics Data System (ADS)
Ghosh, D.; Ray, S.; Roy, H.; Mandal, N.; Shukla, A. K.
2015-12-01
Failure of boiler tubes is the main cause of unit outages of the plant, which further affects the reliability, availability and safety of the unit. So failure analysis of boiler tubes is absolutely essential to predict the root cause of the failure and the steps are taken for future remedial action to prevent the failure in near future. This paper investigates the probable cause/causes of failure of the primary superheater tube in a thermal power plant boiler. Visual inspection, dimensional measurement, chemical analysis, metallographic examination and hardness measurement are conducted as the part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it is concluded that the superheater tube is failed due to graphitization for prolonged exposure of the tube at higher temperature.
Design and construction of a new asphalt drainage layer.
DOT National Transportation Integrated Search
2004-01-01
Because of the importance of having a good drainage mechanism built into a pavement structure to prevent premature failure, the Virginia Department of Transportation (VDOT) has used drainage layers under both portland cement concrete and asphalt conc...
3D Printing of Materials with Tunable Failure via Bioinspired Mechanical Gradients.
Kokkinis, Dimitri; Bouville, Florian; Studart, André R
2018-05-01
Mechanical gradients are useful to reduce strain mismatches in heterogeneous materials and thus prevent premature failure of devices in a wide range of applications. While complex graded designs are a hallmark of biological materials, gradients in manmade materials are often limited to 1D profiles due to the lack of adequate fabrication tools. Here, a multimaterial 3D-printing platform is developed to fabricate elastomer gradients spanning three orders of magnitude in elastic modulus and used to investigate the role of various bioinspired gradient designs on the local and global mechanical behavior of synthetic materials. The digital image correlation data and finite element modeling indicate that gradients can be effectively used to manipulate the stress state and thus circumvent the weakening effect of defect-rich interfaces or program the failure behavior of heterogeneous materials. Implementing this concept in materials with bioinspired designs can potentially lead to defect-tolerant structures and to materials whose tunable failure facilitates repair of biomedical implants, stretchable electronics, or soft robotics. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kuo, Lindsay E; Kaufman, Elinore; Hoffman, Rebecca L; Pascual, Jose L; Martin, Niels D; Kelz, Rachel R; Holena, Daniel N
2017-03-01
Failure-to-rescue is defined as the conditional probability of death after a complication, and the failure-to-rescue rate reflects a center's ability to successfully "rescue" patients after complications. The validity of the failure-to-rescue rate as a quality measure is dependent on the preventability of death and the appropriateness of this measure for use in the trauma population is untested. We sought to evaluate the relationship between preventability and failure-to-rescue in trauma. All adjudications from a mortality review panel at an academic level I trauma center from 2005-2015 were merged with registry data for the same time period. The preventability of each death was determined by panel consensus as part of peer review. Failure-to-rescue deaths were defined as those occurring after any registry-defined complication. Univariate and multivariate logistic regression models between failure-to-rescue status and preventability were constructed and time to death was examined using survival time analyses. Of 26,557 patients, 2,735 (10.5%) had a complication, of whom 359 died for a failure-to-rescue rate of 13.2%. Of failure-to-rescue deaths, 272 (75.6%) were judged to be non-preventable, 65 (18.1%) were judged potentially preventable, and 22 (6.1%) were judged to be preventable by peer review. After adjusting for other patient factors, there remained a strong association between failure-to-rescue status and potentially preventable (odds ratio 2.32, 95% confidence interval, 1.47-3.66) and preventable (odds ratio 14.84, 95% confidence interval, 3.30-66.71) judgment. Despite a strong association between failure-to-rescue status and preventability adjudication, only a minority of deaths meeting the definition of failure to rescue were judged to be preventable or potentially preventable. Revision of the failure-to-rescue metric before use in trauma care benchmarking is warranted. Copyright © 2016 Elsevier Inc. All rights reserved.
Kuo, Lindsay E.; Kaufman, Elinore; Hoffman, Rebecca L.; Pascual, Jose L.; Martin, Niels D.; Kelz, Rachel R.; Holena, Daniel N.
2018-01-01
Background Failure-to-rescue is defined as the conditional probability of death after a complication, and the failure-to-rescue rate reflects a center’s ability to successfully “rescue” patients after complications. The validity of the failure-to-rescue rate as a quality measure is dependent on the preventability of death and the appropriateness of this measure for use in the trauma population is untested. We sought to evaluate the relationship between preventability and failure-to-rescue in trauma. Methods All adjudications from a mortality review panel at an academic level I trauma center from 2005–2015 were merged with registry data for the same time period. The preventability of each death was determined by panel consensus as part of peer review. Failure-to-rescue deaths were defined as those occurring after any registry-defined complication. Univariate and multivariate logistic regression models between failure-to-rescue status and preventability were constructed and time to death was examined using survival time analyses. Results Of 26,557 patients, 2,735 (10.5%) had a complication, of whom 359 died for a failure-to-rescue rate of 13.2%. Of failure-to-rescue deaths, 272 (75.6%) were judged to be non-preventable, 65 (18.1%) were judged potentially preventable, and 22 (6.1%) were judged to be preventable by peer review. After adjusting for other patient factors, there remained a strong association between failure-to-rescue status and potentially preventable (odds ratio 2.32, 95% confidence interval, 1.47–3.66) and preventable (odds ratio 14.84, 95% confidence interval, 3.30–66.71) judgment. Conclusion Despite a strong association between failure-to-rescue status and preventability adjudication, only a minority of deaths meeting the definition of failure to rescue were judged to be preventable or potentially preventable. Revision of the failure-to-rescue metric before use in trauma care benchmarking is warranted. PMID:27788924
[Organ damage and cardiorenal syndrome in acute heart failure].
Casado Cerrada, Jesús; Pérez Calvo, Juan Ignacio
2014-03-01
Heart failure is a complex syndrome that affects almost all organs and systems of the body. Signs and symptoms of organ dysfunction, in particular kidney dysfunction, may be accentuated or become evident for the first time during acute decompensation of heart failure. Cardiorenal syndrome has been defined as the simultaneous dysfunction of both the heart and the kidney, regardless of which of the two organs may have suffered the initial damage and regardless also of their previous functional status. Research into the mechanisms regulating the complex relationship between the two organs is prompting the search for new biomarkers to help physicians detect renal damage in subclinical stages. Hence, a preventive approach to renal dysfunction may be adopted in the clinical setting in the near future. This article provides a general overview of cardiorenal syndrome and an update of the physiopathological mechanisms involved. Special emphasis is placed on the role of visceral congestion as an emergent mechanism in this syndrome. Copyright © 2014 Elsevier España, S.L. All rights reserved.
Performance-based maintenance of gas turbines for reliable control of degraded power systems
NASA Astrophysics Data System (ADS)
Mo, Huadong; Sansavini, Giovanni; Xie, Min
2018-03-01
Maintenance actions are necessary for ensuring proper operations of control systems under component degradation. However, current condition-based maintenance (CBM) models based on component health indices are not suitable for degraded control systems. Indeed, failures of control systems are only determined by the controller outputs, and the feedback mechanism compensates the control performance loss caused by the component deterioration. Thus, control systems may still operate normally even if the component health indices exceed failure thresholds. This work investigates the CBM model of control systems and employs the reduced control performance as a direct degradation measure for deciding maintenance activities. The reduced control performance depends on the underlying component degradation modelled as a Wiener process and the feedback mechanism. To this aim, the controller features are quantified by developing a dynamic and stochastic control block diagram-based simulation model, consisting of the degraded components and the control mechanism. At each inspection, the system receives a maintenance action if the control performance deterioration exceeds its preventive-maintenance or failure thresholds. Inspired by realistic cases, the component degradation model considers random start time and unit-to-unit variability. The cost analysis of maintenance model is conducted via Monte Carlo simulation. Optimal maintenance strategies are investigated to minimize the expected maintenance costs, which is a direct consequence of the control performance. The proposed framework is able to design preventive maintenance actions on a gas power plant, to ensuring required load frequency control performance against a sudden load increase. The optimization results identify the trade-off between system downtime and maintenance costs as a function of preventive maintenance thresholds and inspection frequency. Finally, the control performance-based maintenance model can reduce maintenance costs as compared to CBM and pre-scheduled maintenance.
Metabolic enzymes dysregulation in heart failure: the prospective therapy.
Parihar, Priyanka; Parihar, Mordhwaj Singh
2017-01-01
The heart failure accounts for the highest mortality rate all over the world. The development of preventive therapeutic approaches is still in their infancy. Owing to the extremely high energy demand of the heart, the bioenergetics pathways need to respond efficiently based on substrate availability. The metabolic regulation of such heart bioenergetics is mediated by various rate limiting enzymes involved in energy metabolism. Although all the pertinent mechanisms are not clearly understood, the progressive decline in the activity of metabolic enzymes leading to diminished ATP production is known to cause progression of the heart failure. Therefore, metabolic therapy that can maintain the appropriate activities of metabolic enzymes can be a promising approach for the prevention and treatment of the heart failure. The flavonoids that constitute various human dietary ingredients also effectively offer a variety of health benefits. The flavonoids target a variety of metabolic enzymes and facilitate effective management of the equilibrium between production and utilization of energy in the heart. This review discusses the broad impact of metabolic enzymes in the heart functions and explains how the dysregulated enzyme activity causes the heart failure. In addition, the prospects of targeting dysregulated metabolic enzymes by developing flavonoid-based metabolic approaches are discussed.
Taylor, David; Wilkison, Michelle; Voyich, Jovanka; Meissner, Nicole
2011-05-15
We recently demonstrated that lack of type I IFN signaling (IFNAR knockout) in lymphocyte-deficient mice (IFrag(-/-)) results in bone marrow (BM) failure after Pneumocystis lung infection, whereas lymphocyte-deficient mice with intact IFNAR (RAG(-/-)) had normal hematopoiesis. In the current work, we performed studies to define further the mechanisms involved in the induction of BM failure in this system. BM chimera experiments revealed that IFNAR expression was required on BM-derived but not stroma-derived cells to prevent BM failure. Signals elicited after day 7 postinfection appeared critical in determining BM cell fate. We observed caspase-8- and caspase-9-mediated apoptotic cell death, beginning with neutrophils. Death of myeloid precursors was associated with secondary oxidative stress, and decreasing colony-forming activity in BM cell cultures. Treatment with N-acetylcysteine could slow the progression of, but not prevent, BM failure. Type I IFN signaling has previously been shown to expand the neutrophil life span and regulate the expression of some antiapoptotic factors. Quantitative RT-PCR demonstrated reduced mRNA abundance for the antiapoptotic factors BCL-2, IAP2, MCL-1, and others in BM cells from IFrag(-/-) compared with that in BM cells from RAG(-/-) mice at day 7. mRNA and protein for the proapoptotic cytokine TNF-α was increased, whereas mRNA for the growth factors G-CSF and GM-CSF was reduced. In vivo anti-TNF-α treatment improved precursor cell survival and activity in culture. Thus, we propose that lack of type I IFN signaling results in decreased resistance to inflammation-induced proapoptotic stressors and impaired replenishment by precursors after systemic responses to Pneumocystis lung infection. Our finding may have implications in understanding mechanisms underlying regenerative BM depression/failure during complex immune deficiencies such as AIDS.
Harjola, Veli-Pekka; Mullens, Wilfried; Banaszewski, Marek; Bauersachs, Johann; Brunner-La Rocca, Hans-Peter; Chioncel, Ovidiu; Collins, Sean P; Doehner, Wolfram; Filippatos, Gerasimos S; Flammer, Andreas J; Fuhrmann, Valentin; Lainscak, Mitja; Lassus, Johan; Legrand, Matthieu; Masip, Josep; Mueller, Christian; Papp, Zoltán; Parissis, John; Platz, Elke; Rudiger, Alain; Ruschitzka, Frank; Schäfer, Andreas; Seferovic, Petar M; Skouri, Hadi; Yilmaz, Mehmet Birhan; Mebazaa, Alexandre
2017-07-01
Organ injury and impairment are commonly observed in patients with acute heart failure (AHF), and congestion is an essential pathophysiological mechanism of impaired organ function. Congestion is the predominant clinical profile in most patients with AHF; a smaller proportion presents with peripheral hypoperfusion or cardiogenic shock. Hypoperfusion further deteriorates organ function. The injury and dysfunction of target organs (i.e. heart, lungs, kidneys, liver, intestine, brain) in the setting of AHF are associated with increased risk for mortality. Improvement in organ function after decongestive therapies has been associated with a lower risk for post-discharge mortality. Thus, the prevention and correction of organ dysfunction represent a therapeutic target of interest in AHF and should be evaluated in clinical trials. Treatment strategies that specifically prevent, reduce or reverse organ dysfunction remain to be identified and evaluated to determine if such interventions impact mortality, morbidity and patient-centred outcomes. This paper reflects current understanding among experts of the presentation and management of organ impairment in AHF and suggests priorities for future research to advance the field. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of Cardiology.
Fracture analysis of tube boiler for physical explosion accident.
Kim, Eui Soo
2017-09-01
Material and failure analysis techniques are key tools for determining causation in case of explosive and bursting accident result from material and process defect of product in the field of forensic science. The boiler rupture generated by defect of the welding division, corrosion, overheating and degradation of the material have devastating power. If weak division of boiler burner is fractured by internal pressure, saturated vapor and water is vaporized suddenly. At that time, volume of the saturated vapor and water increases up to thousands of volume. This failure of boiler burner can lead to a fatal disaster. In order to prevent an explosion and of the boiler, it is critical to introduce a systematic investigation and prevention measures in advance. In this research, the cause of boiler failure is investigated through forensic engineering method. Specifically, the failure mechanism will be identified by fractography using scanning electron microscopes (SEM) and Optical Microscopes (OM) and mechanical characterizations. This paper presents a failure analysis of household welding joints for the water tank of a household boiler burner. Visual inspection was performed to find out the characteristics of the fracture of the as-received material. Also, the micro-structural changes such as grain growth and carbide coarsening were examined by optical microscope. Detailed studies of fracture surfaces were made to find out the crack propagation on the weld joint of a boiler burner. It was concluded that the rupture may be caused by overheating induced by insufficient water on the boiler, and it could be accelerated by the metal temperature increase. Copyright © 2017 Elsevier B.V. All rights reserved.
Fiber reinforced sandy slopes under groundwater return flow
USDA-ARS?s Scientific Manuscript database
The instability of natural hillslopes, riverbanks and engineered embankments due to seepage has been a major concern. In an effort to prevent failures, tension resisting synthetic fibers may be an effective additive to increase the mechanical properties of engineered soils. In this study, triaxial c...
NASA Technical Reports Server (NTRS)
Golden, Johnny L.
2016-01-01
The ISS utilizes two large rotating mechanisms, the SARJ, as part of the solar arrays alignment system for more efficient power generation. The SARJ is a 10.3m circumference, nitrided 15-5PH steel race ring of triangular cross-section, with 12 sets of trundle bearing assemblies transferring load across the rolling joint. The SARJ mechanism rotates continuously and slowly - once every orbit, or every 90 minutes. In 2008, the starboard SARJ suffered a lubrication failure, resulting in severe damage (spalling) of one of the race ring surfaces. Extensive effort was conducted to prevent the port SARJ from suffering the same failure, and fortunately was ultimately successful in recovering the functionality of the starboard SARJ. The M&P function was key in determining the cause of failure and the means for mechanism recovery. From a M&P lessons-learned perspective, observations are made concerning the original SARJ design parameters (boundary conditions), the perceived need for nitriding the race ring, the test conditions employed during qualification, the environmental controls used for the hardware preflight, and the lubrication robustness necessary for complex kinematic mechanisms expecting high-reliability and long-life.
NASA Astrophysics Data System (ADS)
Duan, Shu-Qian; Feng, Xia-Ting; Jiang, Quan; Liu, Guo-Feng; Pei, Shu-Feng; Fan, Yi-Lin
2017-09-01
A weak interlayer zone (WIZ) is a poor rock mass system with loose structure, weak mechanical properties, variable thickness, random distribution, strong extension, and high risk due to the shear motion of rock masses under the action of tectonism, bringing many stability problems and geological hazards, especially representing a potential threat to the overall stability of rock masses with WIZs in large underground cavern excavations. Focusing on the deformation and failure problems encountered in the process of excavation unloading, this research proposes comprehensive in situ observation schemes for rock masses with WIZs in large underground cavern on the basis of the collection of geological, construction, monitoring, and testing data. The schemes have been fully applied in two valuable project cases of an underground cavern group under construction in the southwest of China, including the plastic squeezing-out tensile failure and the structural stress-induced collapse of rock masses with WIZs. In this way, the development of rock mass failure, affected by the step-by-step excavations along the cavern's axis and the subsequent excavation downward, could be observed thoroughly. Furthermore, this paper reveals the preliminary analyses of failure mechanism of rock masses with WIZs from several aspects, including rock mass structure, strength, high stress, ground water effects, and microfracture mechanisms. Finally, the failure particularities of rock masses with WIZs and rethink on prevention and control of failures are discussed. The research results could provide important guiding reference value for stability analysis, as well as for rethinking the excavation and support optimization of rock masses with WIZs in similar large underground cavern under high geostress.
Diao, Jianxin; Li, Haiye; Huang, Wei; Ma, Wenxiao; Dai, Huan; Liu, Yawei; Wang, Ming; Hua, He Yu; Ou, Jinying; Sun, Xiaomin; Sun, Xuegang; Yang, Yungao
2017-01-01
Background & Aims: San huang yin chi decoction(SHYCD) is derived from the yin chen hao decoction, a well-known and canonical Chinese medicine formula from the “Treatise on Febrile Diseases”. Over the past decade, SHYCD has been used to treat and prevent the liver cirrhosis and liver failure. In the present study, we investigated the effects of SHYCD for acute on chronic liver failure(ACLF) and explored its potential mechanism. an ACLF rat model, which induced by carbon tetrachloride (CCl4) combined with D-galactosamine (D-GalN) and lipopolysaccharide(LPS), was used and confirmed by B-ultrasound analysis. Rats were randomly divided into control group, model group, SHYCD-H group, SHYCD-M group, SHYCD-L group, AGNHW group. Compared with the ACLF model group, High, medium, and low doses of SHYCD reduced ALT, AST, TBIL, NH3, IL-1β, IL-6, and TNFα expression levels in the serum, Shorten PT and INR time,and increased Fbg content in the whole blood, increased survival rate of the rats, improved liver pathological changes. APE1 / Ref-1 was mainly expressed in the nucleus, but the nucleus and cytoplasm were co-expressed after hepatocyte injury. SHYCD significantly downregulated APE1/Ref-1 expression in the cytoplasm. Increased APE1/Ref-1, Bcl-2, reduced p53, caspase-3, Bax, and Cyt-c in the total protein. Base on the results, we conclused that High, medium, and low doses of SHYCD could be applied in prevention and treatment of ACLF, and dose-dependent. The possible mechanism is to promote the APE1 / Ref-1 from the cytoplasm to the nuclear transfer, regulation of p53 apoptosis signal pathway prevention and treatment of ACLF. PMID:29156683
Primary Prevention of Heart Failure
Butler, Javed
2012-01-01
Most heart failure research and quality improvement efforts are targeted at treatment and secondary prevention of patients with manifest heart failure. This is distinct from coronary disease where primary prevention has been a focus for over three decades. Given the current importance and the projected worsening of heart failure epidemiology, a more focused effort on prevention is urgently needed. PMID:22957272
Huang, Wu-Yang; Davidge, Sandra T; Wu, Jianping
2013-01-01
Prevention and management of hypertension are the major public health challenges worldwide. Uncontrolled high blood pressure may lead to a shortened life expectancy and a higher morbidity due to a high risk of cardiovascular complications such as coronary heart disease (which leads to heart attack) and stroke, congestive heart failure, heart rhythm irregularities, and kidney failure etc. In recent years, it has been recognized that many dietary constituents may contribute to human cardiovascular health. There has been an increased focus on identifying these natural components of foods, describing their physiological activities and mechanisms of actions. Grain, vegetables, fruits, milk, cheese, meat, chicken, egg, fish, soybean, tea, wine, mushrooms, and lactic acid bacteria are various food sources with potential antihypertensive effects. Their main bioactive constituents include angiotensin I-converting enzyme (ACE) inhibitory peptides, vitamins C and E, flavonoids, flavanols, cathecins, anthocyanins, phenolic acids, polyphenols, tannins, resveratrol, polysaccharides, fiber, saponin, sterols, as well as K, Ca, and P. They may reduce blood pressure by different mechanisms, such as ACE inhibition effect, antioxidant, vasodilatory, opiate-like, Ca(2+) channel blocking, and chymase inhibitory activities. These functional foods may provide new therapeutic applications for hypertension prevention and treatment, and contribute to a healthy cardiovascular population. The present review summarizes the antihypertensive food sources and their bioactive constituents, as well as physiological mechanisms of dietary products, especially focusing on ACE inhibitory activity.
Future research directions to improve fistula maturation and reduce access failure
Hu, Haidi; Patel, Sandeep; Hanisch, Jesse J.; Santana, Jeans M.; Hashimoto, Takuya; Bai, Hualong; Kudze, Tambudzai; Foster, Trenton R.; Guo, Jianming; Yatsula, Bogdan; Tsui, Janice; Dardik, Alan
2016-01-01
With the increasing prevalence of end stage renal disease there is a growing need for hemodialysis. Arteriovenous fistulae (AVF) are the preferred type of vascular access for hemodialysis but maturation and failure continue to present significant barriers to successful fistula use. AVF maturation integrates outward remodeling with vessel wall thickening in response to drastic hemodynamic changes, in the setting of uremia, systemic inflammation, oxidative stress and preexistent vascular pathology. AVF can fail due to both failure to mature adequately to support hemodialysis, as well as development of neointimal hyperplasia (NIH) that narrows the AVF lumen, typically near the fistula anastomosis. Failure due to NIH involves vascular cell activation and migration and extracellular matrix remodeling with complex interactions of growth factors, adhesion molecules, inflammatory mediators, and chemokines, all of which result in maladaptive remodeling. Different strategies have been proposed to prevent and treat AVF failure, based on current understanding of the modes and pathology of access failure; these approaches range from appropriate patient selection and use of alternative surgical strategies for fistula creation, to the use of novel interventional techniques or drugs to treat failing fistulae. Effective treatments to prevent or treat AVF failure requires a multidisciplinary approach involving nephrologists, vascular surgeons and interventional radiologists, allowing careful patient selection and the use of tailored systemic or localized interventions to improve patient-specific outcomes. This review provides contemporary information on the underlying mechanisms of AVF maturation and failure and discusses the broad spectrum of options that can be tailored for specific therapy. PMID:28779782
Future research directions to improve fistula maturation and reduce access failure.
Hu, Haidi; Patel, Sandeep; Hanisch, Jesse J; Santana, Jeans M; Hashimoto, Takuya; Bai, Hualong; Kudze, Tambudzai; Foster, Trenton R; Guo, Jianming; Yatsula, Bogdan; Tsui, Janice; Dardik, Alan
2016-12-01
With the increasing prevalence of end-stage renal disease, there is a growing need for hemodialysis. Arteriovenous fistulae (AVF) are the preferred type of vascular access for hemodialysis, but maturation and failure continue to present significant barriers to successful fistula use. AVF maturation integrates outward remodeling with vessel wall thickening in response to drastic hemodynamic changes in the setting of uremia, systemic inflammation, oxidative stress, and pre-existent vascular pathology. AVF can fail due to both failure to mature adequately to support hemodialysis and development of neointimal hyperplasia that narrows the AVF lumen, typically near the fistula anastomosis. Failure due to neointimal hyperplasia involves vascular cell activation and migration and extracellular matrix remodeling with complex interactions of growth factors, adhesion molecules, inflammatory mediators, and chemokines, all of which result in maladaptive remodeling. Different strategies have been proposed to prevent and treat AVF failure based on current understanding of the modes and pathology of access failure; these approaches range from appropriate patient selection and use of alternative surgical strategies for fistula creation, to the use of novel interventional techniques or drugs to treat failing fistulae. Effective treatments to prevent or treat AVF failure require a multidisciplinary approach involving nephrologists, vascular surgeons, and interventional radiologists, careful patient selection, and the use of tailored systemic or localized interventions to improve patient-specific outcomes. This review provides contemporary information on the underlying mechanisms of AVF maturation and failure and discusses the broad spectrum of options that can be tailored for specific therapy. Published by Elsevier Inc.
Intralaminar and Interlaminar Progressive Failure Analysis of Composite Panels with Circular Cutouts
NASA Technical Reports Server (NTRS)
Goyal, Vinay K.; Jaunky, Navin; Johnson, Eric R.; Ambur, Damodar
2002-01-01
A progressive failure methodology is developed and demonstrated to simulate the initiation and material degradation of a laminated panel due to intralaminar and interlaminar failures. Initiation of intralaminar failure can be by a matrix-cracking mode, a fiber-matrix shear mode, and a fiber failure mode. Subsequent material degradation is modeled using damage parameters for each mode to selectively reduce lamina material properties. The interlaminar failure mechanism such as delamination is simulated by positioning interface elements between adjacent sublaminates. A nonlinear constitutive law is postulated for the interface element that accounts for a multi-axial stress criteria to detect the initiation of delamination, a mixed-mode fracture criteria for delamination progression, and a damage parameter to prevent restoration of a previous cohesive state. The methodology is validated using experimental data available in the literature on the response and failure of quasi-isotropic panels with centrally located circular cutouts loaded into the postbuckling regime. Very good agreement between the progressive failure analyses and the experimental results is achieved if the failure analyses includes the interaction of intralaminar and interlaminar failures.
O’Connell, Timothy D.; Jensen, Brian C.; Baker, Anthony J.
2014-01-01
Adrenergic receptors (AR) are G-protein-coupled receptors (GPCRs) that have a crucial role in cardiac physiology in health and disease. Alpha1-ARs signal through Gαq, and signaling through Gq, for example, by endothelin and angiotensin receptors, is thought to be detrimental to the heart. In contrast, cardiac alpha1-ARs mediate important protective and adaptive functions in the heart, although alpha1-ARs are only a minor fraction of total cardiac ARs. Cardiac alpha1-ARs activate pleiotropic downstream signaling to prevent pathologic remodeling in heart failure. Mechanisms defined in animal and cell models include activation of adaptive hypertrophy, prevention of cardiac myocyte death, augmentation of contractility, and induction of ischemic preconditioning. Surprisingly, at the molecular level, alpha1-ARs localize to and signal at the nucleus in cardiac myocytes, and, unlike most GPCRs, activate “inside-out” signaling to cause cardioprotection. Contrary to past opinion, human cardiac alpha1-AR expression is similar to that in the mouse, where alpha1-AR effects are seen most convincingly in knockout models. Human clinical studies show that alpha1-blockade worsens heart failure in hypertension and does not improve outcomes in heart failure, implying a cardioprotective role for human alpha1-ARs. In summary, these findings identify novel functional and mechanistic aspects of cardiac alpha1-AR function and suggest that activation of cardiac alpha1-AR might be a viable therapeutic strategy in heart failure. PMID:24368739
Compliance Issues in Higher Education
ERIC Educational Resources Information Center
Benedek, Petra
2016-01-01
Efficiency in the 1980's, quality in the 1990's, compliance in the 2010's - private sector management techniques and mechanisms find their way to public services. This paper facilitates the understanding of how compliance management controls can improve operations and prevent or detect failure or wrong doing. The last few years' empirical research…
49 CFR 229.49 - Main reservoir system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... inch above the maximum working air pressure fixed by the chief mechanical officer of the carrier... reservoir of air under pressure to be used for operating those power controls. The reservoir shall be provided with means to automatically prevent the loss of pressure in the event of a failure of main air...
49 CFR 229.49 - Main reservoir system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... inch above the maximum working air pressure fixed by the chief mechanical officer of the carrier... reservoir of air under pressure to be used for operating those power controls. The reservoir shall be provided with means to automatically prevent the loss of pressure in the event of a failure of main air...
49 CFR 229.49 - Main reservoir system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... inch above the maximum working air pressure fixed by the chief mechanical officer of the carrier... reservoir of air under pressure to be used for operating those power controls. The reservoir shall be provided with means to automatically prevent the loss of pressure in the event of a failure of main air...
Gribniak, Viktor; Tamulenas, Vytautas; Ng, Pui-Lam; Arnautov, Aleksandr K.; Gudonis, Eugenijus; Misiunaite, Ieva
2017-01-01
This study investigates the mechanical behavior of steel fiber-reinforced concrete (SFRC) beams internally reinforced with steel bars and externally bonded with carbon fiber-reinforced polymer (CFRP) sheets fixed by adhesive and hybrid jointing techniques. In particular, attention is paid to the load resistance and failure modes of composite beams. The steel fibers were used to avoiding the rip-off failure of the concrete cover. The CFRP sheets were fixed to the concrete surface by epoxy adhesive as well as combined with various configurations of small-diameter steel pins for mechanical fastening to form a hybrid connection. Such hybrid jointing techniques were found to be particularly advantageous in avoiding brittle debonding failure, by promoting progressive failure within the hybrid joints. The use of CFRP sheets was also effective in suppressing the localization of the discrete cracks. The development of the crack pattern was monitored using the digital image correlation method. As revealed from the image analyses, with an appropriate layout of the steel pins, brittle failure of the concrete-carbon fiber interface could be effectively prevented. Inverse analysis of the moment-curvature diagrams was conducted, and it was found that a simplified tension-stiffening model with a constant residual stress level at 90% of the strength of the SFRC is adequate for numerically simulating the deformation behavior of beams up to the debonding of the CFRP sheets. PMID:28773024
Gribniak, Viktor; Tamulenas, Vytautas; Ng, Pui-Lam; Arnautov, Aleksandr K; Gudonis, Eugenijus; Misiunaite, Ieva
2017-06-17
This study investigates the mechanical behavior of steel fiber-reinforced concrete (SFRC) beams internally reinforced with steel bars and externally bonded with carbon fiber-reinforced polymer (CFRP) sheets fixed by adhesive and hybrid jointing techniques. In particular, attention is paid to the load resistance and failure modes of composite beams. The steel fibers were used to avoiding the rip-off failure of the concrete cover. The CFRP sheets were fixed to the concrete surface by epoxy adhesive as well as combined with various configurations of small-diameter steel pins for mechanical fastening to form a hybrid connection. Such hybrid jointing techniques were found to be particularly advantageous in avoiding brittle debonding failure, by promoting progressive failure within the hybrid joints. The use of CFRP sheets was also effective in suppressing the localization of the discrete cracks. The development of the crack pattern was monitored using the digital image correlation method. As revealed from the image analyses, with an appropriate layout of the steel pins, brittle failure of the concrete-carbon fiber interface could be effectively prevented. Inverse analysis of the moment-curvature diagrams was conducted, and it was found that a simplified tension-stiffening model with a constant residual stress level at 90% of the strength of the SFRC is adequate for numerically simulating the deformation behavior of beams up to the debonding of the CFRP sheets.
Lemyze, Malcolm; Mallat, Jihad; Nigeon, Olivier; Barrailler, Stéphanie; Pepy, Florent; Gasan, Gaëlle; Vangrunderbeeck, Nicolas; Grosset, Philippe; Tronchon, Laurent; Thevenin, Didier
2013-02-01
To evaluate the impact of switching to total face mask in cases where face mask-delivered noninvasive mechanical ventilation has already failed in do-not-intubate patients in acute respiratory failure. Prospective observational study in an ICU and a respiratory stepdown unit over a 12-month study period. Switching to total face mask, which covers the entire face, when noninvasive mechanical ventilation using facial mask (oronasal mask) failed to reverse acute respiratory failure. Seventy-four patients with a do-not-intubate order and treated by noninvasive mechanical ventilation for acute respiratory failure. Failure of face mask-delivered noninvasive mechanical ventilation was associated with a three-fold increase in in-hospital mortality (36% vs. 10.5%; p = 0.009). Nevertheless, 23 out of 36 patients (64%) in whom face mask-delivered noninvasive mechanical ventilation failed to reverse acute respiratory failure and, therefore, switched to total face mask survived hospital discharge. Reasons for switching from facial mask to total face mask included refractory hypercapnic acute respiratory failure (n = 24, 66.7%), painful skin breakdown or facial mask intolerance (n = 11, 30%), and refractory hypoxemia (n = 1, 2.7%). In the 24 patients switched from facial mask to total face mask because of refractory hypercapnia, encephalopathy score (3 [3-4] vs. 2 [2-3]; p < 0.0001), PaCO2 (87 ± 25 mm Hg vs. 70 ± 17 mm Hg; p < 0.0001), and pH (7.24 ± 0.1 vs. 7.32 ± 0.09; p < 0.0001) significantly improved after 2 hrs of total face mask-delivered noninvasive ventilation. Patients switched early to total face mask (in the first 12 hrs) developed less pressure sores (n = 5, 24% vs. n = 13, 87%; p = 0.0002), despite greater length of noninvasive mechanical ventilation within the first 48 hrs (44 hrs vs. 34 hrs; p = 0.05) and less protective dressings (n = 2, 9.5% vs. n = 8, 53.3%; p = 0.007). The optimal cutoff value for face mask-delivered noninvasive mechanical ventilation duration in predicting facial pressure sores was 11 hrs (area under the receiver operating characteristic curve, 0.86 ± 0.04; 95% confidence interval 0.76-0.93; p < 0.0001; sensitivity, 84%; specificity, 71%). In patients in hypercapnic acute respiratory failure, for whom escalation to intubation is deemed inappropriate, switching to total face mask can be proposed as a last resort therapy when face mask-delivered noninvasive mechanical ventilation has already failed to reverse acute respiratory failure. This strategy is particularly adapted to provide prolonged periods of continuous noninvasive mechanical ventilation while preventing facial pressure sores.
Cauli, Omar; González-Usano, Alba; Cabrera-Pastor, Andrea; Gimenez-Garzó, Carla; López-Larrubia, Pilar; Ruiz-Sauri, Amparo; Hernández-Rabaza, Vicente; Duszczyk, Malgorzata; Malek, Michal; Lazarewicz, Jerzy W; Carratalá, Arturo; Urios, Amparo; Miguel, Alfonso; Torregrosa, Isidro; Carda, Carmen; Montoliu, Carmina; Felipo, Vicente
2014-06-01
Treatment of patients with acute liver failure (ALF) is unsatisfactory and mortality remains unacceptably high. Blocking NMDA receptors delays or prevents death of rats with ALF. The underlying mechanisms remain unclear. Clarifying these mechanisms will help to design more efficient treatments to increase patient's survival. The aim of this work was to shed light on the mechanisms by which blocking NMDA receptors delays rat's death in ALF. ALF was induced by galactosamine injection. NMDA receptors were blocked by continuous MK-801 administration. Edema and cerebral blood flow were assessed by magnetic resonance. The time course of ammonia levels in brain, muscle, blood, and urine; of glutamine, lactate, and water content in brain; of glomerular filtration rate and kidney damage; and of hepatic encephalopathy (HE) and intracranial pressure was assessed. ALF reduces kidney glomerular filtration rate (GFR) as reflected by reduced inulin clearance. GFR reduction is due to both reduced renal perfusion and kidney tubular damage as reflected by increased Kim-1 in urine and histological analysis. Blocking NMDA receptors delays kidney damage, allowing transient increased GFR and ammonia elimination which delays hyperammonemia and associated changes in brain. Blocking NMDA receptors does not prevent cerebral edema or blood-brain barrier permeability but reduces or prevents changes in cerebral blood flow and brain lactate. The data show that dual protective effects of MK-801 in kidney and brain delay cerebral alterations, HE, intracranial pressure increase and death. NMDA receptors antagonists may increase survival of patients with ALF by providing additional time for liver transplantation or regeneration.
Design Studies of Cardiac Valve Prostheses
Liotta, Domingo
1985-01-01
This paper indicates the vital importance of considering prosthesis articulation in the design of cardiac valves. The prosthesis articulation interrelates with the fixed and the movable prosthetic components. Two basic physiological hemodynamic principles are reviewed: [List: see text] A bileaflet, free-tilting, swivelling prosthesis with a central articular mechanism is undergoing investigation. The four articulations have their own perennial preserving mechanisms to prevent potential failure mode by collecting blood elements in the valve tilting design. PMID:15227041
Tiano, Joseph P.; Delghingaro-Augusto, Viviane; Le May, Cedric; Liu, Suhuan; Kaw, Meenakshi K.; Khuder, Saja S.; Latour, Martin G.; Bhatt, Surabhi A.; Korach, Kenneth S.; Najjar, Sonia M.; Prentki, Marc; Mauvais-Jarvis, Franck
2011-01-01
The failure of pancreatic β cells to adapt to an increasing demand for insulin is the major mechanism by which patients progress from insulin resistance to type 2 diabetes (T2D) and is thought to be related to dysfunctional lipid homeostasis within those cells. In multiple animal models of diabetes, females demonstrate relative protection from β cell failure. We previously found that the hormone 17β-estradiol (E2) in part mediates this benefit. Here, we show that treating male Zucker diabetic fatty (ZDF) rats with E2 suppressed synthesis and accumulation of fatty acids and glycerolipids in islets and protected against β cell failure. The antilipogenic actions of E2 were recapitulated by pharmacological activation of estrogen receptor α (ERα) or ERβ in a rat β cell line and in cultured ZDF rat, mouse, and human islets. Pancreas-specific null deletion of ERα in mice (PERα–/–) prevented reduction of lipid synthesis by E2 via a direct action in islets, and PERα–/– mice were predisposed to islet lipid accumulation and β cell dysfunction in response to feeding with a high-fat diet. ER activation inhibited β cell lipid synthesis by suppressing the expression (and activity) of fatty acid synthase via a nonclassical pathway dependent on activated Stat3. Accordingly, pancreas-specific deletion of Stat3 in mice curtailed ER-mediated suppression of lipid synthesis. These data suggest that extranuclear ERs may be promising therapeutic targets to prevent β cell failure in T2D. PMID:21747171
NASA Technical Reports Server (NTRS)
Golden, Johnny L.
2016-01-01
The International Space Station (ISS) utilizes two large rotating mechanisms, the solar alpha rotary joints (SARJs), as part of the solar arrays' alignment system for more efficient power generation. Each SARJ is a 10.3m circumference, nitrided 15-5PH steel race ring of triangular cross-section, with 12 sets of trundle bearing assemblies transferring load across the rolling joint. The SARJ mechanism rotates continuously and slowly - once every orbit, or every 90 minutes. In 2007, the starboard SARJ suffered a lubrication failure, resulting in severe damage (spalling) to one of the race ring surfaces. Extensive effort was conducted to prevent the port SARJ from suffering the same failure, and fortunately that effort was ultimately successful in also recovering the functionality of the starboard SARJ. The M&P engineering function was key in determining the cause of failure and the means for mechanism recovery. From a M&P lessons-learned perspective, observations are made concerning the original SARJ design parameters (boundary conditions), the perceived need for nitriding the race ring, the test conditions employed during qualification, the environmental controls used for the hardware preflight, and the lubrication robustness necessary for complex kinematic mechanisms expecting high-reliability and long-life.
Myostatin regulates energy homeostasis in the heart and prevents heart failure.
Biesemann, Nadine; Mendler, Luca; Wietelmann, Astrid; Hermann, Sven; Schäfers, Michael; Krüger, Marcus; Boettger, Thomas; Borchardt, Thilo; Braun, Thomas
2014-07-07
Myostatin is a major negative regulator of skeletal muscle mass and initiates multiple metabolic changes, including enhanced insulin sensitivity. However, the function of myostatin in the heart is barely understood, although it is upregulated in the myocardium under several pathological conditions. Here, we aimed to decipher the role of myostatin and myostatin-dependent signaling pathways for cardiac function and cardiac metabolism in adult mice. To avoid potential counterregulatory mechanisms occurring in constitutive and germ-line-based myostatin mutants, we generated a mouse model that allows myostatin inactivation in adult cardiomyocytes. Cardiac MRI revealed that genetic inactivation of myostatin signaling in the adult murine heart caused cardiac hypertrophy and heart failure, partially recapitulating effects of the age-dependent decline of the myostatin paralog growth and differentiation factor 11. We found that myostatin represses AMP-activated kinase activation in the heart via transforming growth factor-β-activated kinase 1, thereby preventing a metabolic switch toward glycolysis and glycogen accumulation. Furthermore, myostatin stimulated expression of regulator of G-protein signaling 2, a GTPase-activating protein that restricts Gaq and Gas signaling and thereby protects against cardiac failure. Inhibition of AMP-activated kinase in vivo rescued cardiac hypertrophy and prevented enhanced glycolytic flow and glycogen accumulation after inactivation of myostatin in cardiomyocytes. Our results uncover an important role of myostatin in the heart for maintaining cardiac energy homeostasis and preventing cardiac hypertrophy. © 2014 American Heart Association, Inc.
Time of non-invasive ventilation.
Nava, Stefano; Navalesi, Paolo; Conti, Giorgio
2006-03-01
Non-invasive ventilation (NIV) is a safe, versatile and effective technique that can avert side effects and complications associated with endotracheal intubation. The success of NIV relies on several factors, including the type and severity of acute respiratory failure, the underlying disease, the location of treatment, and the experience of the team. The time factor is also important. NIV is primarily used to avert the need for endotracheal intubation in patients with early-stage acute respiratory failure and post-extubation respiratory failure. It can also be used as an alternative to invasive ventilation at a more advanced stage of acute respiratory failure or to facilitate the process of weaning from mechanical ventilation. NIV has been used to prevent development of acute respiratory failure or post-extubation respiratory failure. The number of days of NIV and hours of daily use differ, depending on the severity and course of the acute respiratory failure and the timing of application. In this review article, we analyse, compare and discuss the results of studies in which NIV was applied at various times during the evolution of acute respiratory failure.
Challenges on non-invasive ventilation to treat acute respiratory failure in the elderly.
Scala, Raffaele
2016-11-15
Acute respiratory failure is a frequent complication in elderly patients especially if suffering from chronic cardio-pulmonary diseases. Non-invasive mechanical ventilation constitutes a successful therapeutic tool in the elderly as, like in younger patients, it is able to prevent endotracheal intubation in a wide range of acute conditions; moreover, this ventilator technique is largely applied in the elderly in whom invasive mechanical ventilation is considered not appropriated. Furthermore, the integration of new technological devices, ethical issues and environment of treatment are still largely debated in the treatment of acute respiratory failure in the elderly.This review aims at reporting and critically analyzing the peculiarities in the management of acute respiratory failure in elderly people, the role of noninvasive mechanical ventilation, the potential advantages of applying alternative or integrated therapeutic tools (i.e. high-flow nasal cannula oxygen therapy, non-invasive and invasive cough assist devices and low-flow carbon-dioxide extracorporeal systems), drawbacks in physician's communication and "end of life" decisions. As several areas of this topic are not supported by evidence-based data, this report takes in account also "real-life" data as well as author's experience.The choice of the setting and of the timing of non-invasive mechanical ventilation in elderly people with advanced cardiopulmonary disease should be carefully evaluated together with the chance of using integrated or alternative supportive devices. Last but not least, economic and ethical issues may often challenges the behavior of the physicians towards elderly people who are hospitalized for acute respiratory failure at the end stage of their cardiopulmonary and neoplastic diseases.
Fear Control an Danger Control: A Test of the Extended Parallel Process Model (EPPM).
ERIC Educational Resources Information Center
Witte, Kim
1994-01-01
Explores cognitive and emotional mechanisms underlying success and failure of fear appeals in context of AIDS prevention. Offers general support for Extended Parallel Process Model. Suggests that cognitions lead to fear appeal success (attitude, intention, or behavior changes) via danger control processes, whereas the emotion fear leads to fear…
Innovation for maintenance technology improvements
NASA Technical Reports Server (NTRS)
Shives, T. R. (Editor); Willard, W. A. (Editor)
1982-01-01
A group of 34 submitted entries (32 papers and 2 abstracts) from the 33rd meeting of the Mechanical Failures Prevention Group whose subject was maintenance technology improvement through innovation. Areas of special emphasis included maintenance concepts, maintenance analysis systems, improved maintenance processes, innovative maintenance diagnostics and maintenance indicators, and technology improvements for power plant applications.
Numerical simulation of failure behavior of granular debris flows based on flume model tests.
Zhou, Jian; Li, Ye-xun; Jia, Min-cai; Li, Cui-na
2013-01-01
In this study, the failure behaviors of debris flows were studied by flume model tests with artificial rainfall and numerical simulations (PFC(3D)). Model tests revealed that grain sizes distribution had profound effects on failure mode, and the failure in slope of medium sand started with cracks at crest and took the form of retrogressive toe sliding failure. With the increase of fine particles in soil, the failure mode of the slopes changed to fluidized flow. The discrete element method PFC(3D) can overcome the hypothesis of the traditional continuous medium mechanic and consider the simple characteristics of particle. Thus, a numerical simulations model considering liquid-solid coupled method has been developed to simulate the debris flow. Comparing the experimental results, the numerical simulation result indicated that the failure mode of the failure of medium sand slope was retrogressive toe sliding, and the failure of fine sand slope was fluidized sliding. The simulation result is consistent with the model test and theoretical analysis, and grain sizes distribution caused different failure behavior of granular debris flows. This research should be a guide to explore the theory of debris flow and to improve the prevention and reduction of debris flow.
Symons, Nicholas R A; Almoudaris, Alex M; Nagpal, Kamal; Vincent, Charles A; Moorthy, Krishna
2013-01-01
To investigate the nature of process failures in postoperative care, to assess their frequency and preventability, and to explore their relationship to adverse events. Adverse events are common and are frequently caused by failures in the process of care. These processes are often evaluated independently using clinical audit. There is little understanding of process failures in terms of their overall frequency, relative risk, and cumulative effect on the surgical patient. Patients were observed daily from the first postoperative day until discharge by an independent surgeon. Field notes on the circumstances surrounding any nonroutine or atypical event were recorded. Field notes were assessed by 2 surgeons to identify failures in the process of care. Preventability, the degree of harm caused to the patient, and the underlying etiology of process failures were evaluated by 2 independent surgeons. Fifty patients undergoing major elective general surgery were observed for a total of 659 days of postoperative care. A total of 256 process failures were identified, of which 85% were preventable and 51% directly led to patient harm. Process failures occurred in all aspects of care, the most frequent being medication prescribing and administration, management of lines, tubes, and drains, and pain control interventions. Process failures accounted for 57% of all preventable adverse events. Communication failures and delays were the main etiologies, leading to 54% of process failures. Process failures are common in postoperative care, are highly preventable, and frequently cause harm to patients. Interventions to prevent process failures will improve the reliability of surgical postoperative care and have the potential to reduce hospital stay.
Landslide Frequency and Failure Mechanisms at NE Gela Basin (Strait of Sicily)
NASA Astrophysics Data System (ADS)
Kuhlmann, J.; Asioli, A.; Trincardi, F.; Klügel, A.; Huhn, K.
2017-11-01
Despite intense research by both academia and industry, the parameters controlling slope stability at continental margins are often speculated upon. Lack of core recovery and age control on failed sediments prevent the assessment of failure timing/frequency and the role of prefailure architecture as shaped by paleoenvironmental changes. This study uses an integrated chronological framework from two boreholes and complementary ultrahigh-resolution acoustic profiling in order to assess (1) the frequency of submarine landsliding at the continental margin of NE Gela Basin and (2) the associated mechanisms of failure. Accurate age control was achieved through absolute radiocarbon dating and indirect dating relying on isotope stratigraphic and micropaleontological reconstructions. A total of nine major slope failure events have been recognized that occurred within the last 87 kyr ( 10 kyr return frequency), though there is evidence for additional syndepositional, small-scaled transport processes of lower volume. Preferential failure involves translational movement of mudflows along subhorizontal surfaces that are induced by sedimentological changes relating to prefailure stratal architecture. Along with sequence-stratigraphic boundaries reflecting paleoenvironmental fluctuations, recovered core material suggests that intercalated volcaniclastic layers are key to the basal confinement and lateral movement of these events in the study area. Another major predisposing factor is given by rapid loading of fine-grained homogenous strata and successive generation of excess pore pressure, as expressed by several fluid escape structures. Recurrent failure, however, requires repeated generation of favorable conditions, and seismic activity, though low if compared to many other Mediterranean settings, is shown to represent a legitimate trigger mechanism.
Saba, Samir; Mathier, Michael A.; Mehdi, Haider; Gursoy, Erdal; Liu, Tong; Choi, Bum-Rak; Salama, Guy; London, Barry
2008-01-01
Background: Biventricular (BIV) pacing can improve cardiac function in heart failure (HF). Objective: To investigate the mechanisms of benefit of BIV pacing using a rabbit model of myocardial infarction (MI). Methods: New Zealand White rabbits were divided into 4 groups: sham-operated (C), MI with no pacing (MI), MI with right ventricular pacing (MI+RV), and MI with BIV pacing (MI+BIV), and underwent serial electrocardiograms and echocardiograms. At 4 weeks, hearts were excised and tissue was extracted from various areas of the left ventricle (LV). Results: Four weeks after coronary ligation, BIV pacing prevented systolic and diastolic dilation of the LV as well as the reduction in its fractional shortening, restored the QRS width and the rate-dependent QT intervals to their baseline values, and prevented the decline of the ether-a-go-go (erg) protein levels. This prevention of remodeling was not documented in the MI+RV groups. Conclusions: In this rabbit model of BIV pacing and MI, we demonstrate prevention of adverse mechanical and electrical remodeling of the heart. These changes may underlie some of the benefits seen with BIV pacing in HF patients with more severe LV dysfunction. PMID:18180026
Estrogen prevents bone loss through transforming growth factor β signaling in T cells
Gao, Yuhao; Qian, Wei-Ping; Dark, Kimberly; Toraldo, Gianluca; Lin, Angela S. P.; Guldberg, Robert E.; Flavell, Richard A.; Weitzmann, M. Neale; Pacifici, Roberto
2004-01-01
Estrogen (E) deficiency leads to an expansion of the pool of tumor necrosis factor (TNF)-producing T cells through an IFN-γ-dependent pathway that results in increased levels of the osteoclastogenic cytokine TNF in the bone marrow. Disregulated IFN-γ production is instrumental for the bone loss induced by ovariectomy (ovx), but the responsible mechanism is unknown. We now show that mice with T cell-specific blockade of type β transforming growth factor (TGFβ) signaling are completely insensitive to the bone-sparing effect of E. This phenotype results from a failure of E to repress IFN-γ production, which, in turn, leads to increased T cell activation and T cell TNF production. Furthermore, ovx blunts TGFβ levels in the bone marrow, and overexpression of TGFβ in vivo prevents ovx-induced bone loss. These findings demonstrate that E prevents bone loss through a TGFβ-dependent mechanism, and that TGFβ signaling in T cells preserves bone homeostasis by blunting T cell activation. Thus, stimulation of TGFβ production in the bone marrow is a critical “upstream” mechanism by which E prevents bone loss, and enhancement of TGFβ levels in vivo may constitute a previously undescribed therapeutic approach for preventing bone loss. PMID:15531637
Younus, H.; Anwar, S.
2016-01-01
Non-enzymatic glycosylation (glycation) plays an important role in the development of physiological and pathophysiological processes such as aging, diabetes, atherosclerosis, neurodegenerative diseases and chronic renal failure. Preventing glycation can minimize diabetic complications. Glycation can be prevented by the natural defence system in the body, synthetic inhibitors and natural inhibitors. Synthetic inhibitors may prevent glycation through several possible mechanisms. They might inhibit the glycation by interfering with the attachment of sugars with proteins, by inhibiting the late stage of glycation or by preventing Amadori product formation. Furthermore, their ability to scavenge free radicals and to break cross-links might be other mechanisms responsible for their potential to inhibit glycation. Naturally occurring phytochemicals/products have been found to be relatively non-toxic as compared to synthetic compounds, and are inexpensive and available in an ingestible form. A large number of plants and natural biomolecules have been shown to have antidiabetic effects. Several hypoglycaemic compounds have anti-oxidant properties. The present review describes the various ways in which glycation can be prevented. PMID:27103908
Wang, Qingtong; Liu, Yongming; Fu, Qin; Xu, Bing; Zhang, Yuan; Kim, Sungjin; Tan, Ruensern; Barbagallo, Federica; West, Toni; Anderson, Ethan; Wei, Wei; Abel, E Dale; Xiang, Yang K
2017-01-03
Type 2 diabetes mellitus (DM) and obesity independently increase the risk of heart failure by incompletely understood mechanisms. We propose that hyperinsulinemia might promote adverse consequences in the hearts of subjects with type-2 DM and obesity. High-fat diet feeding was used to induce obesity and DM in wild-type mice or mice lacking β 2 -adrenergic receptor (β 2 AR) or β-arrestin2. Wild-type mice fed with high-fat diet were treated with a β-blocker carvedilol or a GRK2 (G-protein-coupled receptor kinase 2) inhibitor. We examined signaling and cardiac contractile function. High-fat diet feeding selectively increases the expression of phosphodiesterase 4D (PDE4D) in mouse hearts, in concert with reduced protein kinase A phosphorylation of phospholamban, which contributes to systolic and diastolic dysfunction. The expression of PDE4D is also elevated in human hearts with DM. The induction of PDE4D expression is mediated by an insulin receptor, insulin receptor substrate, and GRK2 and β-arrestin2-dependent transactivation of a β 2 AR-extracellular regulated protein kinase signaling cascade. Thus, pharmacological inhibition of β 2 AR or GRK2, or genetic deletion of β 2 AR or β-arrestin2, all significantly attenuate insulin-induced phosphorylation of extracellular regulated protein kinase and PDE4D induction to prevent DM-related contractile dysfunction. These studies elucidate a novel mechanism by which hyperinsulinemia contributes to heart failure by increasing PDE4D expression and identify β 2 AR or GRK2 as plausible therapeutic targets for preventing or treating heart failure in subjects with type 2 DM. © 2016 American Heart Association, Inc.
Tethered Satellite System Contingency Investigation Board
NASA Technical Reports Server (NTRS)
1992-01-01
The Tethered Satellite System (TSS-1) was launched aboard the Space Shuttle Atlantis (STS-46) on July 31, 1992. During the attempted on-orbit operations, the Tethered Satellite System failed to deploy successfully beyond 256 meters. The satellite was retrieved successfully and was returned on August 6, 1992. The National Aeronautics and Space Administration (NASA) Associate Administrator for Space Flight formed the Tethered Satellite System (TSS-1) Contingency Investigation Board on August 12, 1992. The TSS-1 Contingency Investigation Board was asked to review the anomalies which occurred, to determine the probable cause, and to recommend corrective measures to prevent recurrence. The board was supported by the TSS Systems Working group as identified in MSFC-TSS-11-90, 'Tethered Satellite System (TSS) Contingency Plan'. The board identified five anomalies for investigation: initial failure to retract the U2 umbilical; initial failure to flyaway; unplanned tether deployment stop at 179 meters; unplanned tether deployment stop at 256 meters; and failure to move tether in either direction at 224 meters. Initial observations of the returned flight hardware revealed evidence of mechanical interference by a bolt with the level wind mechanism travel as well as a helical shaped wrap of tether which indicated that the tether had been unwound from the reel beyond the travel by the level wind mechanism. Examination of the detailed mission events from flight data and mission logs related to the initial failure to flyaway and the failure to move in either direction at 224 meters, together with known preflight concerns regarding slack tether, focused the assessment of these anomalies on the upper tether control mechanism. After the second meeting, the board requested the working group to complete and validate a detailed integrated mission sequence to focus the fault tree analysis on a stuck U2 umbilical, level wind mechanical interference, and slack tether in upper tether control mechanism and to prepare a detailed plan for hardware inspection, test, and analysis including any appropriate hardware disassembly.
Tethered Satellite System Contingency Investigation Board
NASA Astrophysics Data System (ADS)
1992-11-01
The Tethered Satellite System (TSS-1) was launched aboard the Space Shuttle Atlantis (STS-46) on July 31, 1992. During the attempted on-orbit operations, the Tethered Satellite System failed to deploy successfully beyond 256 meters. The satellite was retrieved successfully and was returned on August 6, 1992. The National Aeronautics and Space Administration (NASA) Associate Administrator for Space Flight formed the Tethered Satellite System (TSS-1) Contingency Investigation Board on August 12, 1992. The TSS-1 Contingency Investigation Board was asked to review the anomalies which occurred, to determine the probable cause, and to recommend corrective measures to prevent recurrence. The board was supported by the TSS Systems Working group as identified in MSFC-TSS-11-90, 'Tethered Satellite System (TSS) Contingency Plan'. The board identified five anomalies for investigation: initial failure to retract the U2 umbilical; initial failure to flyaway; unplanned tether deployment stop at 179 meters; unplanned tether deployment stop at 256 meters; and failure to move tether in either direction at 224 meters. Initial observations of the returned flight hardware revealed evidence of mechanical interference by a bolt with the level wind mechanism travel as well as a helical shaped wrap of tether which indicated that the tether had been unwound from the reel beyond the travel by the level wind mechanism. Examination of the detailed mission events from flight data and mission logs related to the initial failure to flyaway and the failure to move in either direction at 224 meters, together with known preflight concerns regarding slack tether, focused the assessment of these anomalies on the upper tether control mechanism. After the second meeting, the board requested the working group to complete and validate a detailed integrated mission sequence to focus the fault tree analysis on a stuck U2 umbilical, level wind mechanical interference, and slack tether in upper tether control mechanism and to prepare a detailed plan for hardware inspection, test, and analysis including any appropriate hardware disassembly.
The pathophysiological basis of the protective effects of metformin in heart failure.
Dziubak, Aleksandra; Wójcicka, Grażyna
2017-08-24
Metformin, currently recommended as the drug of first choice in type 2 diabetes mellitus (T2DM), is one of the few antihiperglycemic drugs to reduce cardiovascular risk. Nonetheless, due to the risk of lactic acidosis during metformin therapy, its usage in patients with diabetes and heart failure (HF) is still a matter of debate. The aim of this review is to present data supporting the possibility of using metformin in the treatment of diabetic patients with concomitant heart failure. In the failing heart, metformin through the mechanism related to AMP-activated protein kinase (AMPK) activity, improves free fatty acids (FFA) and glucose metabolism, mitochondrial biogenesis, as well as nitric oxide (NO)-NO synthase pathway. Metformin can also inhibit the generation and accumulation of advanced glycation end products (AGEs) and thereby prevents the development of the adverse structural and functional changes in myocardium.In summary, experimental and clinical data indicate the ability of metformin to prevent the development of the structural and functional changes in myocardium, although further basic research and clinical studies assessing benefits and safety of metformin therapy in patients with HF are required.
Role of Protein Quality Control Failure in Alcoholic Hepatitis Pathogenesis.
French, Samuel W; Masouminia, Maryam; Samadzadeh, Sara; Tillman, Brittany C; Mendoza, Alejandro; French, Barbara A
2017-02-08
The mechanisms of protein quality control in hepatocytes in cases of alcoholic hepatitis (AH) including ufmylation, FAT10ylation, metacaspase 1 (Mca1), ERAD (endoplasmic reticulum-associated degradation), JUNQ (juxta nuclear quality control), IPOD (insoluble protein deposit) autophagocytosis, and ER stress are reviewed. The Mallory-Denk body (MDB) formation develops in the hepatocytes in alcoholic hepatitis as a consequence of the failure of these protein quality control mechanisms to remove misfolded and damaged proteins and to prevent MDB aggresome formation within the cytoplasm of hepatocytes. The proteins involved in the quality control pathways are identified, quantitated, and visualized by immunofluorescent antibody staining of liver biopsies from patients with AH. Quantification of the proteins are achieved by measuring the fluorescent intensity using a morphometric system. Ufmylation and FAT10ylation pathways were downregulated, Mca1 pathways were upregulated, autophagocytosis was upregulated, and ER stress PERK (protein kinase RNA-like endoplasmic reticulum kinase) and CHOP (CCAAT/enhancer-binding protein homologous protein) mechanisms were upregulated. Despite the upregulation of several pathways of protein quality control, aggresomes (MDBs) still formed in the hepatocytes in AH. The pathogenesis of AH is due to the failure of protein quality control, which causes balloon-cell change with MDB formation and ER stress.
LMI-based adaptive reliable H∞ static output feedback control against switched actuator failures
NASA Astrophysics Data System (ADS)
An, Liwei; Zhai, Ding; Dong, Jiuxiang; Zhang, Qingling
2017-08-01
This paper investigates the H∞ static output feedback (SOF) control problem for switched linear system under arbitrary switching, where the actuator failure models are considered to depend on switching signal. An active reliable control scheme is developed by combination of linear matrix inequality (LMI) method and adaptive mechanism. First, by exploiting variable substitution and Finsler's lemma, new LMI conditions are given for designing the SOF controller. Compared to the existing results, the proposed design conditions are more relaxed and can be applied to a wider class of no-fault linear systems. Then a novel adaptive mechanism is established, where the inverses of switched failure scaling factors are estimated online to accommodate the effects of actuator failure on systems. Two main difficulties arise: first is how to design the switched adaptive laws to prevent the missing of estimating information due to switching; second is how to construct a common Lyapunov function based on a switched estimate error term. It is shown that the new method can give less conservative results than that for the traditional control design with fixed gain matrices. Finally, simulation results on the HiMAT aircraft are given to show the effectiveness of the proposed approaches.
Hernández, Gonzalo; Vaquero, Concepción; Colinas, Laura; Cuena, Rafael; González, Paloma; Canabal, Alfonso; Sanchez, Susana; Rodriguez, Maria Luisa; Villasclaras, Ana; Fernández, Rafael
2016-10-18
High-flow conditioned oxygen therapy delivered through nasal cannulae and noninvasive mechanical ventilation (NIV) may reduce the need for reintubation. Among the advantages of high-flow oxygen therapy are comfort, availability, lower costs, and additional physiopathological mechanisms. To test if high-flow conditioned oxygen therapy is noninferior to NIV for preventing postextubation respiratory failure and reintubation in patients at high risk of reintubation. Multicenter randomized clinical trial in 3 intensive care units in Spain (September 2012-October 2014) including critically ill patients ready for planned extubation with at least 1 of the following high-risk factors for reintubation: older than 65 years; Acute Physiology and Chronic Health Evaluation II score higher than 12 points on extubation day; body mass index higher than 30; inadequate secretions management; difficult or prolonged weaning; more than 1 comorbidity; heart failure as primary indication for mechanical ventilation; moderate to severe chronic obstructive pulmonary disease; airway patency problems; or prolonged mechanical ventilation. Patients were randomized to undergo either high-flow conditioned oxygen therapy or NIV for 24 hours after extubation. Primary outcomes were reintubation and postextubation respiratory failure within 72 hours. Noninferiority margin was 10 percentage points. Secondary outcomes included respiratory infection, sepsis, and multiple organ failure, length of stay and mortality; adverse events; and time to reintubation. Of 604 patients (mean age, 65 [SD, 16] years; 388 [64%] men), 314 received NIV and 290 high-flow oxygen. Sixty-six patients (22.8%) in the high-flow group vs 60 (19.1%) in the NIV group were reintubation (absolute difference, -3.7%; 95% CI, -9.1% to ∞); 78 patients (26.9%) in the high-flow group vs 125 (39.8%) in the NIV group experienced postextubation respiratory failure (risk difference, 12.9%; 95% CI, 6.6% to ∞) [corrected]. Median time to reintubation did not significantly differ: 26.5 hours (IQR, 14-39 hours) in the high-flow group vs 21.5 hours (IQR, 10-47 hours) in the NIV group (absolute difference, -5 hours; 95% CI, -34 to 24 hours). Median postrandomization ICU length of stay was lower in the high-flow group, 3 days (IQR, 2-7) vs 4 days (IQR, 2-9; P=.048). Other secondary outcomes were similar in the 2 groups. Adverse effects requiring withdrawal of the therapy were observed in none of patients in the high-flow group vs 42.9% patients in the NIV group (P < .001). Among high-risk adults who have undergone extubation, high-flow conditioned oxygen therapy was not inferior to NIV for preventing reintubation and postextubation respiratory failure. High-flow conditioned oxygen therapy may offer advantages for these patients. clinicaltrials.gov Identifier: NCT01191489.
Morbi, Abigail H M; Hamady, Mohamad S; Riga, Celia V; Kashef, Elika; Pearch, Ben J; Vincent, Charles; Moorthy, Krishna; Vats, Amit; Cheshire, Nicholas J W; Bicknell, Colin D
2012-08-01
To determine the type and frequency of errors during vascular interventional radiology (VIR) and design and implement an intervention to reduce error and improve efficiency in this setting. Ethical guidance was sought from the Research Services Department at Imperial College London. Informed consent was not obtained. Field notes were recorded during 55 VIR procedures by a single observer. Two blinded assessors identified failures from field notes and categorized them into one or more errors by using a 22-part classification system. The potential to cause harm, disruption to procedural flow, and preventability of each failure was determined. A preprocedural team rehearsal (PPTR) was then designed and implemented to target frequent preventable potential failures. Thirty-three procedures were observed subsequently to determine the efficacy of the PPTR. Nonparametric statistical analysis was used to determine the effect of intervention on potential failure rates, potential to cause harm and procedural flow disruption scores (Mann-Whitney U test), and number of preventable failures (Fisher exact test). Before intervention, 1197 potential failures were recorded, of which 54.6% were preventable. A total of 2040 errors were deemed to have occurred to produce these failures. Planning error (19.7%), staff absence (16.2%), equipment unavailability (12.2%), communication error (11.2%), and lack of safety consciousness (6.1%) were the most frequent errors, accounting for 65.4% of the total. After intervention, 352 potential failures were recorded. Classification resulted in 477 errors. Preventable failures decreased from 54.6% to 27.3% (P < .001) with implementation of PPTR. Potential failure rates per hour decreased from 18.8 to 9.2 (P < .001), with no increase in potential to cause harm or procedural flow disruption per failure. Failures during VIR procedures are largely because of ineffective planning, communication error, and equipment difficulties, rather than a result of technical or patient-related issues. Many of these potential failures are preventable. A PPTR is an effective means of targeting frequent preventable failures, reducing procedural delays and improving patient safety.
NASA Astrophysics Data System (ADS)
Brahimi, S. V.; Yue, S.; Sriraman, K. R.
2017-06-01
High-strength steel fasteners characterized by tensile strengths above 1100 MPa are often used in critical applications where a failure can have catastrophic consequences. Preventing hydrogen embrittlement (HE) failure is a fundamental concern implicating the entire fastener supply chain. Research is typically conducted under idealized conditions that cannot be translated into know-how prescribed in fastener industry standards and practices. Additionally, inconsistencies and even contradictions in fastener industry standards have led to much confusion and many preventable or misdiagnosed fastener failures. HE susceptibility is a function of the material condition, which is comprehensively described by the metallurgical and mechanical properties. Material strength has a first-order effect on HE susceptibility, which increases significantly above 1200 MPa and is characterized by a ductile-brittle transition. For a given concentration of hydrogen and at equal strength, the critical strength above which the ductile-brittle transition begins can vary due to second-order effects of chemistry, tempering temperature and sub-microstructure. Additionally, non-homogeneity of the metallurgical structure resulting from poorly controlled heat treatment, impurities and non-metallic inclusions can increase HE susceptibility of steel in ways that are measurable but unpredictable. Below 1200 MPa, non-conforming quality is often the root cause of real-life failures. This article is part of the themed issue 'The challenges of hydrogen and metals'.
76 FR 8661 - Airworthiness Directives; Lycoming Engines, Fuel Injected Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-15
... engine models requiring inspections. We are proposing this AD to prevent failure of the fuel injector... repetitive inspection compliance time. We issued that AD to prevent failure of the fuel injector fuel lines... engine models requiring inspection. We are issuing this AD to prevent failure of the fuel injector fuel...
Hamo, Carine E; Bloom, Michelle W; Cardinale, Daniela; Ky, Bonnie; Nohria, Anju; Baer, Lea; Skopicki, Hal; Lenihan, Daniel J; Gheorghiade, Mihai; Lyon, Alexander R; Butler, Javed
2016-02-01
Success with oncologic treatment has allowed cancer patients to experience longer cancer-free survival gains. Unfortunately, this success has been tempered by unintended and often devastating cardiac complications affecting overall patient outcomes. Cardiac toxicity, specifically the association of several cancer therapy agents with the development of left ventricular dysfunction and cardiomyopathy, is an issue of growing concern. Although the pathophysiologic mechanisms behind cardiac toxicity have been characterized, there is currently no evidence-based approach for monitoring and management of these patients. In the first of a 2-part review, we discuss the epidemiologic, pathophysiologic, risk factors, and imaging aspects of cancer therapy-related cardiac dysfunction and heart failure. In this second part, we discuss the prevention and treatment aspects in these patients and conclude with highlighting the evidence gaps and future directions for research in this area. © 2016 American Heart Association, Inc.
Statistical Analysis on the Mechanical Properties of Magnesium Alloys
Liu, Ruoyu; Jiang, Xianquan; Zhang, Hongju; Zhang, Dingfei; Wang, Jingfeng; Pan, Fusheng
2017-01-01
Knowledge of statistical characteristics of mechanical properties is very important for the practical application of structural materials. Unfortunately, the scatter characteristics of magnesium alloys for mechanical performance remain poorly understood until now. In this study, the mechanical reliability of magnesium alloys is systematically estimated using Weibull statistical analysis. Interestingly, the Weibull modulus, m, of strength for magnesium alloys is as high as that for aluminum and steels, confirming the very high reliability of magnesium alloys. The high predictability in the tensile strength of magnesium alloys represents the capability of preventing catastrophic premature failure during service, which is essential for safety and reliability assessment. PMID:29113116
Space Plasma Shown to Make Satellite Solar Arrays Fail
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.
1999-01-01
In 1997, scientists and engineers of the Photovoltaic and Space Environments Branch of the NASA Lewis Research Center, Maxwell Technologies, and Space Systems/Loral discovered a new failure mechanism for solar arrays on communications satellites in orbit. Sustained electrical arcs, initiated by the space plasma and powered by the solar arrays themselves, were found to have destroyed solar array substrates on some Space Systems/Loral satellites, leading to array failure. The mechanism was tested at Lewis, and mitigation strategies were developed to prevent such disastrous occurrences on-orbit in the future. Deep Space 1 is a solar-electric-powered space mission to a comet, launched on October 24, 1998. Early in 1998, scientists at Lewis and Ballistic Missile Defense Organization (BMDO) realized that some aspects of the Deep Space 1 solar arrays were nearly identical to those that had led to the failure of solar arrays on Space Systems/Loral satellites. They decided to modify the Deep Space 1 arrays to prevent catastrophic failure in space. The arrays were suitably modified and are now performing optimally in outer space. Finally, the Earth Observing System (EOS) AM1, scheduled for launch in mid-1999, is a NASA mission managed by the Goddard Space Flight Center. Realizing the importance of Lewis testing on the Loral arrays, EOS-AM1 management asked Lewis scientists to test their solar arrays to show that they would not fail in the same way. The first phase of plasma testing showed that sustained arcing would occur on the unmodified EOS-AM1 arrays, so the arrays were removed from the spacecraft and fixed. Now, Lewis scientists have finished plasma testing of the modified array configuration to ensure that EOS-AM1 will have no sustained arcing problems on-orbit.
Acute Right Ventricle Failure in the Intensive Care Unit: Assessment and Management.
Hrymak, Carmen; Strumpher, Johann; Jacobsohn, Eric
2017-01-01
Caring for the critically ill patient with acute right ventricle (RV) failure is a diagnostic and management challenge. A thorough understanding of normal RV anatomy and physiology is essential to manage RV failure. Despite the fact that the RV is essentially a volume chamber that ejects into a low-pressure system, the left ventricle contributes significantly to RV function through maintenance of the transseptal gradient (TSG). Preserving systemic mean arterial pressure maintains the TSG and RV perfusion. Various pathological states cause acute RV failure by decreasing the TSG and RV perfusion and/or increasing pulmonary vascular resistance. Early diagnosis prevents rapid progression of RV failure due to the "double hit phenomenon," which is acute intra-abdominal multiple organ system failure as a result of a reduced blood pressure and elevated central venous pressure. Management includes hemodynamic support and reversal of the precipitating cause through optimizing RV rate and rhythm, determining ideal RV filling pressure, reducing RV afterload through nonpharmacologic and pharmacological means, and selecting the appropriate RV inotrope or mechanical support. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-13
..., preventing gravity feed. In the event of scavenge system failure, the collector tank fuel level can no longer... closed by the valve spring, preventing gravity feed. In the event of scavenge system failure, the... spring, preventing gravity feed. In the event of scavenge system failure, the collector tank fuel level...
Mechanical Expansion of Steel Tubing as a Solution to Leaky Wellbores
Radonjic, Mileva; Kupresan, Darko
2014-01-01
Wellbore cement, a procedural component of wellbore completion operations, primarily provides zonal isolation and mechanical support of the metal pipe (casing), and protects metal components from corrosive fluids. These are essential for uncompromised wellbore integrity. Cements can undergo multiple forms of failure, such as debonding at the cement/rock and cement/metal interfaces, fracturing, and defects within the cement matrix. Failures and defects within the cement will ultimately lead to fluid migration, resulting in inter-zonal fluid migration and premature well abandonment. Currently, there are over 1.8 million operating wells worldwide and over one third of these wells have leak related problems defined as Sustained Casing Pressure (SCP)1. The focus of this research was to develop an experimental setup at bench-scale to explore the effect of mechanical manipulation of wellbore casing-cement composite samples as a potential technology for the remediation of gas leaks. The experimental methodology utilized in this study enabled formation of an impermeable seal at the pipe/cement interface in a simulated wellbore system. Successful nitrogen gas flow-through measurements demonstrated that an existing microannulus was sealed at laboratory experimental conditions and fluid flow prevented by mechanical manipulation of the metal/cement composite sample. Furthermore, this methodology can be applied not only for the remediation of leaky wellbores, but also in plugging and abandonment procedures as well as wellbore completions technology, and potentially preventing negative impacts of wellbores on subsurface and surface environments. PMID:25490436
Mechanical expansion of steel tubing as a solution to leaky wellbores.
Radonjic, Mileva; Kupresan, Darko
2014-11-20
Wellbore cement, a procedural component of wellbore completion operations, primarily provides zonal isolation and mechanical support of the metal pipe (casing), and protects metal components from corrosive fluids. These are essential for uncompromised wellbore integrity. Cements can undergo multiple forms of failure, such as debonding at the cement/rock and cement/metal interfaces, fracturing, and defects within the cement matrix. Failures and defects within the cement will ultimately lead to fluid migration, resulting in inter-zonal fluid migration and premature well abandonment. Currently, there are over 1.8 million operating wells worldwide and over one third of these wells have leak related problems defined as Sustained Casing Pressure (SCP). The focus of this research was to develop an experimental setup at bench-scale to explore the effect of mechanical manipulation of wellbore casing-cement composite samples as a potential technology for the remediation of gas leaks. The experimental methodology utilized in this study enabled formation of an impermeable seal at the pipe/cement interface in a simulated wellbore system. Successful nitrogen gas flow-through measurements demonstrated that an existing microannulus was sealed at laboratory experimental conditions and fluid flow prevented by mechanical manipulation of the metal/cement composite sample. Furthermore, this methodology can be applied not only for the remediation of leaky wellbores, but also in plugging and abandonment procedures as well as wellbore completions technology, and potentially preventing negative impacts of wellbores on subsurface and surface environments.
Jiang, Chuan; Esquinas, Antonio; Mina, Bushra
2017-01-01
A crucial step in the transition from mechanical ventilation to extubation is the successful performance of a spontaneous breathing trial (SBT). The American College of Chest Physicians (ACCP) Guidelines recommend removal of the endotracheal tube upon successful completion of a SBT. However, this does not guarantee successful extubation as there remains a risk of re-intubation. Guidelines have outlined ventilator liberation protocols, selected use of non-invasive ventilation on extubation, early mobilization, and dynamic ventilator metrics to prevent and better predict extubation failure. However, a significant percentage of patients still fail mechanical ventilation discontinuation. A common reason for re-intubation is having a weak cough strength, which reflects the inability to protect the airway. Evaluation of cough strength via objective measures using peak expiratory flow rate is a non-invasive and easily reproducible assessment which can predict extubation failure. We conducted a narrative review of the literature regarding use of cough strength as a predictive index for extubation failure risk. Results of our review show that cough strength, quantified objectively with a cough peak expiratory flow measurement (CPEF), is strongly associated with extubation success. Furthermore, various cutoff thresholds have been identified and can provide reasonable diagnostic accuracy and predictive power for extubation failure. These results demonstrate that measurement of the CPEF can be a useful tool to predict extubation failure in patients on MV who have passed a SBT. In addition, the data suggest that this diagnostic modality may reduce ICU length of stay, ICU expenditures, and morbidity and mortality.
Kario, Kazuomi
2018-01-27
Sacubitril/valsartan (LCZ696) is a first-in-class, novel-acting, angiotensin receptor neprilysin inhibitor (ARNI) that provides inhibition of neprilysin and the angiotensin (AT 1 ) receptor. A recent clinical trial PRARDIGM-HF demonstrated that this drug is superior to angiotensin-converting enzyme (ACE) inhibitors for improving the prognosis in the patients with heart failure, and this has resulted in the drug being included in clinical practice guidelines for the management of heart failure with reduced ejection fraction (EF). In addition, sacubitril/valsartan has been developed for the management of hypertension, because it has unique anti-aging properties. However, the clinical evidence of mechanism has not been well validated. A recent mechanistic study PARAMETER demonstrated that sacubitril/valsartan (LCZ696) is superior to angiotensin receptor blocker (ARB) monotherapy for reducing central aortic systolic pressure (primary endpoint) as well as for central aortic pulse pressure (secondary endpoint) and nocturnal BP preferentially. Considering these results, sacubitril/valsartan may be an attractive therapeutic agent to treat the elderly with age-related hypertension phenotypes, such as drug-uncontrolled (resistant) hypertension characterized as systolic (central) hypertension (structural hypertension) and/or nocturnal hypertension (salt-sensitive hypertension). These are the high-risk hypertension phenotypes which are prone to develop heart failure with preserved EF and chronic kidney disease. Sacubitril/valsartan may be effective to suppress the age-related continuum from hypertension to heart failure, and it could be clinically useful not only for secondary prevention, but also as primary prevention of heart failure in uncontrolled elderly hypertensive patients.
Martín-González, F; González-Robledo, J; Sánchez-Hernández, F; Moreno-García, M N; Barreda-Mellado, I
2016-01-01
To assess the effectiveness and identify predictors of failure of noninvasive ventilation. A retrospective, longitudinal descriptive study was made. Adult patients with acute respiratory failure. A total of 410 consecutive patients with noninvasive ventilation treated in an Intensive Care Unit of a tertiary university hospital from 2006 to 2011. Noninvasive ventilation. Demographic variables and clinical and laboratory test parameters at the start and two hours after the start of noninvasive ventilation. Evolution during admission to the Unit and until hospital discharge. The failure rate was 50%, with an overall mortality rate of 33%. A total of 156 patients had hypoxemic respiratory failure, 87 postextubation respiratory failure, 78 exacerbation of chronic obstructive pulmonary disease, 61 hypercapnic respiratory failure without chronic obstructive pulmonary disease, and 28 had acute pulmonary edema. The failure rates were 74%, 54%, 27%, 31% and 21%, respectively. The etiology of respiratory failure, serum bilirubin at the start, APACHEII score, radiological findings, the need for sedation to tolerate noninvasive ventilation, changes in level of consciousness, PaO2/FIO2 ratio, respiratory rate and heart rate from the start and two hours after the start of noninvasive ventilation were independently associated to failure. The effectiveness of noninvasive ventilation varies according to the etiology of respiratory failure. Its use in hypoxemic respiratory failure and postextubation respiratory failure should be assessed individually. Predictors of failure could be useful to prevent delayed intubation. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.
The chromatin-binding protein Smyd1 restricts adult mammalian heart growth
Kimball, Todd; Rasmussen, Tara L.; Rosa-Garrido, Manuel; Chen, Haodong; Tran, Tam; Miller, Mickey R.; Gray, Ricardo; Jiang, Shanxi; Ren, Shuxun; Wang, Yibin; Tucker, Haley O.; Vondriska, Thomas M.
2016-01-01
All terminally differentiated organs face two challenges, maintaining their cellular identity and restricting organ size. The molecular mechanisms responsible for these decisions are of critical importance to organismal development, and perturbations in their normal balance can lead to disease. A hallmark of heart failure, a condition affecting millions of people worldwide, is hypertrophic growth of cardiomyocytes. The various forms of heart failure in human and animal models share conserved transcriptome remodeling events that lead to expression of genes normally silenced in the healthy adult heart. However, the chromatin remodeling events that maintain cell and organ size are incompletely understood; insights into these mechanisms could provide new targets for heart failure therapy. Using a quantitative proteomics approach to identify muscle-specific chromatin regulators in a mouse model of hypertrophy and heart failure, we identified upregulation of the histone methyltransferase Smyd1 during disease. Inducible loss-of-function studies in vivo demonstrate that Smyd1 is responsible for restricting growth in the adult heart, with its absence leading to cellular hypertrophy, organ remodeling, and fulminate heart failure. Molecular studies reveal Smyd1 to be a muscle-specific regulator of gene expression and indicate that Smyd1 modulates expression of gene isoforms whose expression is associated with cardiac pathology. Importantly, activation of Smyd1 can prevent pathological cell growth. These findings have basic implications for our understanding of cardiac pathologies and open new avenues to the treatment of cardiac hypertrophy and failure by modulating Smyd1. PMID:27663768
The chromatin-binding protein Smyd1 restricts adult mammalian heart growth.
Franklin, Sarah; Kimball, Todd; Rasmussen, Tara L; Rosa-Garrido, Manuel; Chen, Haodong; Tran, Tam; Miller, Mickey R; Gray, Ricardo; Jiang, Shanxi; Ren, Shuxun; Wang, Yibin; Tucker, Haley O; Vondriska, Thomas M
2016-11-01
All terminally differentiated organs face two challenges, maintaining their cellular identity and restricting organ size. The molecular mechanisms responsible for these decisions are of critical importance to organismal development, and perturbations in their normal balance can lead to disease. A hallmark of heart failure, a condition affecting millions of people worldwide, is hypertrophic growth of cardiomyocytes. The various forms of heart failure in human and animal models share conserved transcriptome remodeling events that lead to expression of genes normally silenced in the healthy adult heart. However, the chromatin remodeling events that maintain cell and organ size are incompletely understood; insights into these mechanisms could provide new targets for heart failure therapy. Using a quantitative proteomics approach to identify muscle-specific chromatin regulators in a mouse model of hypertrophy and heart failure, we identified upregulation of the histone methyltransferase Smyd1 during disease. Inducible loss-of-function studies in vivo demonstrate that Smyd1 is responsible for restricting growth in the adult heart, with its absence leading to cellular hypertrophy, organ remodeling, and fulminate heart failure. Molecular studies reveal Smyd1 to be a muscle-specific regulator of gene expression and indicate that Smyd1 modulates expression of gene isoforms whose expression is associated with cardiac pathology. Importantly, activation of Smyd1 can prevent pathological cell growth. These findings have basic implications for our understanding of cardiac pathologies and open new avenues to the treatment of cardiac hypertrophy and failure by modulating Smyd1. Copyright © 2016 the American Physiological Society.
On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sappok, Alex; Ragaller, Paul; Herman, Andrew
The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this study, radio frequency (RF) sensors were used to directlymore » monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.« less
Correlated seed failure as an environmental veto to synchronize reproduction of masting plants.
Bogdziewicz, Michał; Steele, Michael A; Marino, Shealyn; Crone, Elizabeth E
2018-07-01
Variable, synchronized seed production, called masting, is a widespread reproductive strategy in plants. Resource dynamics, pollination success, and, as described here, environmental veto are possible proximate mechanisms driving masting. We explored the environmental veto hypothesis, which assumes that reproductive synchrony is driven by external factors preventing reproduction in some years, by extending the resource budget model of masting with correlated reproductive failure. We ran this model across its parameter space to explore how key parameters interact to drive seeding dynamics. Next, we parameterized the model based on 16 yr of seed production data for populations of red (Quercus rubra) and white (Quercus alba) oaks. We used these empirical models to simulate seeding dynamics, and compared simulated time series with patterns observed in the field. Simulations showed that resource dynamics and reproduction failure can produce masting even in the absence of pollen coupling. In concordance with this, in both oaks, among-year variation in resource gain and correlated reproductive failure were necessary and sufficient to reproduce masting, whereas pollen coupling, although present, was not necessary. Reproductive failure caused by environmental veto may drive large-scale synchronization without density-dependent pollen limitation. Reproduction-inhibiting weather events are prevalent in ecosystems, making described mechanisms likely to operate in many systems. © 2018 The Authors New Phytologist © 2018 New Phytologist Trust.
The renal nerves in chronic heart failure: efferent and afferent mechanisms
Schiller, Alicia M.; Pellegrino, Peter R.; Zucker, Irving H.
2015-01-01
The function of the renal nerves has been an area of scientific and medical interest for many years. The recent advent of a minimally invasive catheter-based method of renal denervation has renewed excitement in understanding the afferent and efferent actions of the renal nerves in multiple diseases. While hypertension has been the focus of much this work, less attention has been given to the role of the renal nerves in the development of chronic heart failure (CHF). Recent studies from our laboratory and those of others implicate an essential role for the renal nerves in the development and progression of CHF. Using a rabbit tachycardia model of CHF and surgical unilateral renal denervation, we provide evidence for both renal efferent and afferent mechanisms in the pathogenesis of CHF. Renal denervation prevented the decrease in renal blood flow observed in CHF while also preventing increases in Angiotensin-II receptor protein in the microvasculature of the renal cortex. Renal denervation in CHF also reduced physiological markers of autonomic dysfunction including an improvement in arterial baroreflex function, heart rate variability, and decreased resting cardiac sympathetic tone. Taken together, the renal sympathetic nerves are necessary in the pathogenesis of CHF via both efferent and afferent mechanisms. Additional investigation is warranted to fully understand the role of these nerves and their role as a therapeutic target in CHF. PMID:26300788
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klishin, G.S.; Seleznev, V.E.; Aleoshin, V.V.
1997-12-31
Gas industry enterprises such as main pipelines, compressor gas transfer stations, gas extracting complexes belong to the energy intensive industry. Accidents there can result into the catastrophes and great social, environmental and economic losses. Annually, according to the official data several dozens of large accidents take place at the pipes in the USA and Russia. That is why prevention of the accidents, analysis of the mechanisms of their development and prediction of their possible consequences are acute and important tasks nowadays. The accidents reasons are usually of a complicated character and can be presented as a complex combination of natural,more » technical and human factors. Mathematical and computer simulations are safe, rather effective and comparatively inexpensive methods of the accident analysis. It makes it possible to analyze different mechanisms of a failure occurrence and development, to assess its consequences and give recommendations to prevent it. Besides investigation of the failure cases, numerical simulation techniques play an important role in the treatment of the diagnostics results of the objects and in further construction of mathematical prognostic simulations of the object behavior in the period of time between two inspections. While solving diagnostics tasks and in the analysis of the failure cases, the techniques of theoretical mechanics, of qualitative theory of different equations, of mechanics of a continuous medium, of chemical macro-kinetics and optimizing techniques are implemented in the Conversion Design Bureau {number_sign}5 (DB{number_sign}5). Both universal and special numerical techniques and software (SW) are being developed in DB{number_sign}5 for solution of such tasks. Almost all of them are calibrated on the calculations of the simulated and full-scale experiments performed at the VNIIEF and MINATOM testing sites. It is worth noting that in the long years of work there has been established a fruitful and effective collaboration of theoreticians, mathematicians and experimentalists of the institute to solve such tasks.« less
Biological Mechanisms by Which Antiproliferative Actions of Resveratrol Are Minimized.
Ho, Yih; Lin, Yu-Syuan; Liu, Hsuan-Liang; Shih, Ya-Jung; Lin, Shin-Ying; Shih, Ai; Chin, Yu-Tang; Chen, Yi-Ru; Lin, Hung-Yun; Davis, Paul J
2017-09-21
Preclinical and clinical studies have offered evidence for protective effects of various polyphenol-rich foods against cardiovascular diseases, neurodegenerative diseases, and cancers. Resveratrol is among the most widely studied polyphenols. However, the preventive and treatment effectiveness of resveratrol in cancer remain controversial because of certain limitations in existing studies. For example, studies of the activity of resveratrol against cancer cell lines in vitro have often been conducted at concentrations in the low μM to mM range, whereas dietary resveratrol or resveratrol-containing wine rarely achieve nM concentrations in the clinic. While the mechanisms underlying the failure of resveratrol to inhibit cancer growth in the intact organism are not fully understood, the interference by thyroid hormones with the anticancer activity of resveratrol have been well documented in both in vitro and xenograft studies. Thus, endogenous thyroid hormones may explain the failure of anticancer actions of resveratrol in intact animals, or in the clinic. In this review, mechanisms involved in resveratrol-induced antiproliferation and effects of thyroid hormones on these mechanisms are discussed.
NASA Astrophysics Data System (ADS)
Paranjpe, Nikhil; Alamir, Mohammed; Alonayni, Abdullah; Asmatulu, Eylem; Rahman, Muhammad M.; Asmatulu, Ramazan
2018-03-01
Adhesives are widely utilized materials in aviation, automotive, energy, defense, and marine industries. Adhesive joints are gradually supplanting mechanical fasteners because they are lightweight structures, thus making the assembly lighter and easier. They also act as a sealant to prevent a structural joint from galvanic corrosion and leakages. Adhesive bonds provide high joint strength because of the fact that the load is distributed uniformly on the joint surface, while in mechanical joints, the load is concentrated at one point, thus leading to stress at that point and in turn causing joint failures. This research concentrated on the analysis of bond strength and failure loads in adhesive joint of composite-to-composite surfaces. Different durations of plasma along with the detergent cleaning were conducted on the composite surfaces prior to the adhesive applications and curing processes. The joint strength of the composites increased about 34% when the surface was plasma treated for 12 minutes. It is concluded that the combination of different surface preparations, rather than only one type of surface treatment, provides an ideal joint quality for the composites.
NASA Astrophysics Data System (ADS)
Zhou, Zilong; Chen, Lu; Zhao, Yuan; Zhao, Tongbin; Cai, Xin; Du, Xueming
2017-04-01
To reveal the mechanical response of a multi-pillar supporting system under external loads, compressive tests were carried out on single-pillar and double-pillar specimens. The digital speckle correlation method and acoustic emission technique were applied to record and analyse information of the deformation and failure processes. Numerical simulations with the software programme PFC2D were also conducted. In the compressive process of the double-pillar system, if both individual pillars have the same mechanical properties, each pillar deforms similarly and reaches the critical stable state almost simultaneously by sharing equal loads. If the two individual pillars have different mechanical properties, the pillar with higher elastic modulus or lower strength would be damaged and lose its bearing capacity firstly. The load would then be transferred to the other pillar under a load redistribution process. When the pillar with higher strength is strong enough, the load carried by the pillar system would increase again. However, the maximum bearing load of the double-pillar system is smaller than the sum of peak load of individual pillars. The study also indicates that the strength, elastic modulus, and load state of pillars all influence the supporting capacity of the pillar system. In underground space engineering, the appropriate choice of pillar dimensions and layout may play a great role in preventing the occurrence of cascading pillar failure.
Driving forces behind the construction of an eco-compensation mechanism for wetlands in China
NASA Astrophysics Data System (ADS)
Wang, Changhai
2016-09-01
This research revealed important driving forces behind the construction of an eco-compensation mechanism for wetlands (DFEMW) in China. Using China's provincial panel data from 1978 to 2008, a fixed-effects model was used to analyze the impacts of agricultural production systems on wetlands. We identified three DFEMW as follows: the change of wetland resources and protection measures in China; declaration and implementation of the provincial Wetland Protection Ordinance; and wetland degradation by agricultural production systems, which necessitated the establishment of a wetland eco-compensation mechanism. In addition to the DFEMW, a significant positive correlation between wetland area and both rural population and gross agricultural production was identified, in addition to a negative correlation with chemical fertilizer usage, reservoir storage capacity, and irrigation area. The underlying reasons for the serious degradation and inadequate protection of wetlands were market failure and government failure; these were the driving forces behind the need to establish a wetland eco-compensation mechanism. From a governmental perspective, it has been difficult to rectify market failures in resource distribution and thus to prevent wetland degradation. Factors include conflicts of interest, lack of investment, effective special laws, a simple means to protect wetlands, and a multidisciplinary management system. Therefore, the key factor is the coordination of interest relationships between those who utilize wetlands and those who seek to minimize wetland degradation and effectively protect wetlands.
Chu, Kuo-An; Hsu, Chien-Wei; Lin, Min-Hsi; Lin, Shyh-Jer; Huang, Yi-Luan
2015-03-01
Extramedullary hematopoiesis (EMH) is a compensatory response to many chronic anemic disorders. Intrathoracic EMH, usually presenting as paravertebral masses over the posterior mediastinum, is a rare entity and is usually asymptomatic. Hemothorax is a rare but possibly fatal complication. Local radiation for intrathoracic EMH is considered effective in preventing its recurrence. Here we describe a patient who had had α-thalassemia for many years and developed a spontaneous left-sided hemothorax from EMH. A chest film and a chest computed tomography (CT) scan had showed multiple paravertebral masses over the lower thoracic spine with left-sided pleural effusion. A pathological diagnosis of EMH was made by video-assisted thoracoscopic surgery. The patient had not received preventive local chest radiation. Ten years later, he suffered from a life-threatening hemothorax complicated by acute respiratory failure without traumatic history. A CT scan showed posterior mediastinal masses over the lower thoracic spine with right-sided pleural effusion. Thoracoscopy was performed to remove the blood clot in the pleural space for successful weaning from mechanical ventilation. This is the first case of intrathoracic EMH to have recurrent hemothorax associated with acute respiratory failure. Copyright © 2012. Published by Elsevier B.V.
Space Stirling Cryocooler Contamination Lessons Learned and Recommended Control Procedures
NASA Astrophysics Data System (ADS)
Glaister, D. S.; Price, K.; Gully, W.; Castles, S.; Reilly, J.
The most important characteristic of a space cryocooler is its reliability over a lifetime typically in excess of 7 years. While design improvements have reduced the probability of mechanical failure, the risk of internal contamination is still significant and has not been addressed in a consistent approach across the industry. A significant fraction of the endurance test and flight units have experienced some performance degradation related to internal contamination. The purpose of this paper is to describe and assess the contamination issues inside long life, space cryocoolers and to recommend procedures to minimize the probability of encountering contamination related failures and degradation. The paper covers the sources of contamination, the degradation and failure mechanisms, the theoretical and observed cryocooler sensitivity, and the recommended prevention procedures and their impact. We begin with a discussion of the contamination sources, both artificial and intrinsic. Next, the degradation and failure mechanisms are discussed in an attempt to arrive at a contaminant susceptibility, from which we can derive a contamination budget for the machine. This theoretical sensitivity is then compared with the observed sensitivity to illustrate the conservative nature of the assumed scenarios. A number of lessons learned on Raytheon, Ball, Air Force Research Laboratory, and NASA GSFC programs are shared to convey the practical aspects of the contamination problem. Then, the materials and processes required to meet the proposed budget are outlined. An attempt is made to present a survey of processes across industry.
NASA Astrophysics Data System (ADS)
Galassi, S.
2018-05-01
In this paper a mechanical model of masonry arches strengthened with fibre-reinforced composite materials and the relevant numerical procedure for the analysis are proposed. The arch is modelled by using an assemblage of rigid blocks that are connected together and, also to the supporting structures, by mortar joints. The presence of the reinforcement, usually a sheet placed at the intrados or the extrados, prevents the occurrence of cracks that could activate possible collapse mechanisms, due to tensile failure of the mortar joints. Therefore, in a reinforced arch failure generally occurs in a different way from the URM arch. The numerical procedure proposed checks, as a function of an external incremental load, the inner stress state in the arch, in the reinforcement and in the adhesive layer. In so doing, it then provides a prediction of failure modes. Results obtained from experimental tests, carried out on four in-scale models performed in a laboratory, have been compared with those provided by the numerical procedure, implemented in ArchiVAULT, a software developed by the author. In this regard, the numerical procedure is an extension of previous works. Although additional experimental investigations are necessary, these former results confirm that the proposed numerical procedure is promising.
NASA Technical Reports Server (NTRS)
Stewart, Helen; Spence, Matt Chew; Holm, Jeanne; Koga, Dennis (Technical Monitor)
2001-01-01
This white paper explores how to increase the success and operation of critical, complex, national systems by effectively capturing knowledge management requirements within the federal acquisition process. Although we focus on aerospace flight systems, the principles outlined within may have a general applicability to other critical federal systems as well. Fundamental design deficiencies in federal, mission-critical systems have contributed to recent, highly visible system failures, such as the V-22 Osprey and the Delta rocket family. These failures indicate that the current mechanisms for knowledge management and risk management are inadequate to meet the challenges imposed by the rising complexity of critical systems. Failures of aerospace system operations and vehicles may have been prevented or lessened through utilization of better knowledge management and information management techniques.
Yeganeh, Ali; Otoukesh, Babak; Kaghazian, Peyman; Yeganeh, Nima; Boddohi, Bahram; Moghtadaei, Mehdi
2015-01-01
Background: Orthopedics implants are important tools for treatment of bone fractures. Despite available recommendations for designing and making the implants, there are multiple cases of fracture of these implants in the body. Hence, in this study the frequency of failure of implants in long bones of lower extremities was evaluated. Methods and Materials: In this cross-sectional study, two types of fractured implants in the body were analyzed and underwent metalogical, mechanical, and modeling and stress-bending analysis. Results: The results revealed that the main cause of fractures was decreased mechanical resistance due to inappropriate chemical composition (especially decreased percentages of Nickel and Molybdenum). Conclusions: It may be concluded that following the standard chemical composition and use of optimal making method are the most important works for prevention of failure of implants. PMID:26843735
Intelligence Failure: How a Commander Can Prevent It
2009-10-23
Failure: How a Commander Can Prevent It The job of intelligence is to provide the decision maker with sufficient understanding of the enemy to make...Failure: How a Commander Can Prevent It The job of intelligence is to provide the decision maker with sufficient understanding of the enemy to make...reinforce these lessons. 1 Introduction The job of intelligence is to provide the decision maker with sufficient understanding of
Ghanta, Ravi K; Rangaraj, Aravind; Umakanthan, Ramanan; Lee, Lawrence; Laurence, Rita G; Fox, John A; Bolman, R Morton; Cohn, Lawrence H; Chen, Frederick Y
2007-03-13
Ventricular restraint is a nontransplantation surgical treatment for heart failure. The effect of varying restraint level on left ventricular (LV) mechanics and remodeling is not known. We hypothesized that restraint level may affect therapy efficacy. We studied the immediate effect of varying restraint levels in an ovine heart failure model. We then studied the long-term effect of restraint applied over a 2-month period. Restraint level was quantified by use of fluid-filled epicardial balloons placed around the ventricles and measurement of balloon luminal pressure at end diastole. At 4 different restraint levels (0, 3, 5, and 8 mm Hg), transmural myocardial pressure (P(tm)) and indices of myocardial oxygen consumption (MVO2) were determined in control (n=5) and ovine heart failure (n=5). Ventricular restraint therapy decreased P(tm) and MVO2, and improved mechanical efficiency. An optimal physiological restraint level of 3 mm Hg was identified to maximize improvement without an adverse affect on systemic hemodynamics. At this optimal level, end-diastolic P(tm) and MVO2 indices decreased by 27% and 20%, respectively. The serial longitudinal effects of optimized ventricular restraint were then evaluated in ovine heart failure with (n=3) and without (n=3) restraint over 2 months. Optimized ventricular restraint prevented and reversed pathological LV dilatation (130+/-22 mL to 91+/-18 mL) and improved LV ejection fraction (27+/-3% to 43+/-5%). Measured restraint level decreased over time as the LV became smaller, and reverse remodeling slowed. Ventricular restraint level affects the degree of decrease in P(tm), the degree of decrease in MVO2, and the rate of LV reverse remodeling. Periodic physiological adjustments of restraint level may be required for optimal restraint therapy efficacy.
Eclov, Julie A.; Qian, Qingwen; Redetzke, Rebecca; Chen, Quanhai; Wu, Steven C.; Healy, Chastity L.; Ortmeier, Steven B.; Harmon, Erin; Shearer, Gregory C.; O’Connell, Timothy D.
2015-01-01
Heart failure with preserved ejection fraction (HFpEF) is half of all HF, but standard HF therapies are ineffective. Diastolic dysfunction, often secondary to interstitial fibrosis, is common in HFpEF. Previously, we found that supra-physiologic levels of ω3-PUFAs produced by 12 weeks of ω3-dietary supplementation prevented fibrosis and contractile dysfunction following pressure overload [transverse aortic constriction (TAC)], a model that resembles aspects of remodeling in HFpEF. This raised several questions regarding ω3-concentration-dependent cardioprotection, the specific role of EPA and DHA, and the relationship between prevention of fibrosis and contractile dysfunction. To achieve more clinically relevant ω3-levels and test individual ω3-PUFAs, we shortened the ω3-diet regimen and used EPA- and DHA-specific diets to examine remodeling following TAC. The shorter diet regimen produced ω3-PUFA levels closer to Western clinics. Further, EPA, but not DHA, prevented fibrosis following TAC. However, neither ω3-PUFA prevented contractile dysfunction, perhaps due to reduced uptake of ω3-PUFA. Interestingly, EPA did not accumulate in cardiac fibroblasts. However, FFA receptor 4, a G protein-coupled receptor for ω3-PUFAs, was sufficient and required to block transforming growth factor β1-fibrotic signaling in cultured cardiac fibroblasts, suggesting a novel mechanism for EPA. In summary, EPA-mediated prevention of fibrosis could represent a novel therapy for HFpEF. PMID:26435012
p53 protects against genome instability following centriole duplication failure
Lambrus, Bramwell G.; Uetake, Yumi; Clutario, Kevin M.; Daggubati, Vikas; Snyder, Michael; Sluder, Greenfield
2015-01-01
Centriole function has been difficult to study because of a lack of specific tools that allow persistent and reversible centriole depletion. Here we combined gene targeting with an auxin-inducible degradation system to achieve rapid, titratable, and reversible control of Polo-like kinase 4 (Plk4), a master regulator of centriole biogenesis. Depletion of Plk4 led to a failure of centriole duplication that produced an irreversible cell cycle arrest within a few divisions. This arrest was not a result of a prolonged mitosis, chromosome segregation errors, or cytokinesis failure. Depleting p53 allowed cells that fail centriole duplication to proliferate indefinitely. Washout of auxin and restoration of endogenous Plk4 levels in cells that lack centrioles led to the penetrant formation of de novo centrioles that gained the ability to organize microtubules and duplicate. In summary, we uncover a p53-dependent surveillance mechanism that protects against genome instability by preventing cell growth after centriole duplication failure. PMID:26150389
Data-Driven Packet Loss Estimation for Node Healthy Sensing in Decentralized Cluster.
Fan, Hangyu; Wang, Huandong; Li, Yong
2018-01-23
Decentralized clustering of modern information technology is widely adopted in various fields these years. One of the main reason is the features of high availability and the failure-tolerance which can prevent the entire system form broking down by a failure of a single point. Recently, toolkits such as Akka are used by the public commonly to easily build such kind of cluster. However, clusters of such kind that use Gossip as their membership managing protocol and use link failure detecting mechanism to detect link failures cannot deal with the scenario that a node stochastically drops packets and corrupts the member status of the cluster. In this paper, we formulate the problem to be evaluating the link quality and finding a max clique (NP-Complete) in the connectivity graph. We then proposed an algorithm that consists of two models driven by data from application layer to respectively solving these two problems. Through simulations with statistical data and a real-world product, we demonstrate that our algorithm has a good performance.
Failure Scenarios and Mitigations for the BABAR Superconducting Solenoid
NASA Astrophysics Data System (ADS)
Thompson, EunJoo; Candia, A.; Craddock, W. W.; Racine, M.; Weisend, J. G.
2006-04-01
The cryogenic department at the Stanford Linear Accelerator Center is responsible for the operation, troubleshooting, and upgrade of the 1.5 Tesla superconducting solenoid detector for the BABAR B-factory experiment. Events that disable the detector are rare but significantly impact the availability of the detector for physics research. As a result, a number of systems and procedures have been developed over time to minimize the downtime of the detector, for example improved control systems, improved and automatic backup systems, and spares for all major components. Together they can prevent or mitigate many of the failures experienced by the utilities, mechanical systems, controls and instrumentation. In this paper we describe various failure scenarios, their effect on the detector, and the modifications made to mitigate the effects of the failure. As a result of these modifications the reliability of the detector has increased significantly with only 3 shutdowns of the detector due to cryogenics systems over the last 2 years.
Addressing the Challenges of Hepatitis C Virus Resistance and Treatment Failure.
Colpitts, Che C; Baumert, Thomas F
2016-08-16
Chronic hepatitis C is a major cause of chronic liver disease, including liver cirrhosis and hepatocellular carcinoma. The development of direct-acting antivirals (DAAs) revolutionized hepatitis C virus (HCV) treatment by offering genuine prospects for the first comprehensive cure of a chronic viral infection in humans. While antiviral resistance is a significant limitation for interferon-based therapies, resistance and treatment failure still appear to be present in a small fraction of patients even in state-of-the-art DAA combination therapies. Therefore, treatment failure and resistance still remain a clinical challenge for the management of patients not responding to DAAs. In this special issue of Viruses on HCV drug resistance, mechanisms of antiviral resistance for different classes of antiviral drugs are described. Furthermore, the detection and monitoring of resistance in clinical practice, the clinical impact of resistance in different patient groups and strategies to prevent and address resistance and treatment failure using complementary antiviral strategies are reviewed.
Zanella, Alberto; Cressoni, Massimo; Epp, Myra; Hoffmann, Viktoria; Stylianou, Mario; Kolobow, Theodor
2012-04-01
Orientation of the trachea and tracheal tube below horizontal may prevent aspiration of oropharyngeal secretions into the lungs, which is a pivotal pathway in the pathogenesis of ventilator-associated pneumonia (VAP). The incidence of VAP was evaluated in swine with orientation of trachea and tracheal tube above horizontal (model of semirecumbent position, currently recommended in patients) and below horizontal. Twenty-six mini-pigs were randomized into four groups: (A) eight mechanically ventilated with orientation of trachea 45° above horizontal for 72 h. In the remaining groups (B, C, D) the trachea was oriented 10° below horizontal, with (B) six mechanically ventilated for 72 h, (C) six mechanically ventilated for 72 h with enteral feeding, and (D) six mechanically ventilated for 168 h with enteral feeding. At the end of the study period, all pigs were sacrificed and the clinical diagnosis of VAP was microbiologically evaluated. No antibiotics were administered. All eight pigs kept orientated with the trachea 45° above horizontal developed VAP and respiratory failure (PaO(2)/F(i)O(2) = 132 ± 139 mmHg) with a median of 5.5 pulmonary lobes out of 6 colonized with average colonization of 9.3 × 10(7) CFU/g. None of the 18 pigs kept oriented with the trachea below horizontal developed VAP; 16 had sterile lungs, while 2, ventilated for 7 days, developed a low level of colonization. Orientation of the trachea above horizontal was uniformly associated with VAP and respiratory failure; positioning the trachea below horizontal consistently prevented development of VAP.
Stem cell therapy for the systemic right ventricle.
Si, Ming-Sing; Ohye, Richard G
2017-11-01
In specific forms of congenital heart defects and pulmonary hypertension, the right ventricle (RV) is exposed to systemic levels of pressure overload. The RV is prone to failure in these patients because of its vulnerability to chronic pressure overload. As patients with a systemic RV reach adulthood, an emerging epidemic of RV failure has become evident. Medical therapies proven for LV failure are ineffective in treating RV failure. Areas covered: In this review, the pathophysiology of the failing RV under pressure overload is discussed, with specific emphasis on the pivotal roles of angiogenesis and oxidative stress. Studies investigating the ability of stem cell therapy to improve angiogenesis and mitigate oxidative stress in the setting of pressure overload are then reviewed. Finally, clinical trials utilizing stem cell therapy to prevent RV failure under pressure overload in congenital heart disease will be discussed. Expert commentary: Although considerable hurdles remain before their mainstream clinical implementation, stem cell therapy possesses revolutionary potential in the treatment of patients with failing systemic RVs who currently have very limited long-term treatment options. Rigorous clinical trials of stem cell therapy for RV failure that target well-defined mechanisms will ensure success adoption of this therapeutic strategy.
Pituskin, Edith; Haykowsky, Mark; Mackey, John R; Thompson, Richard B; Ezekowitz, Justin; Koshman, Sheri; Oudit, Gavin; Chow, Kelvin; Pagano, Joseph J; Paterson, Ian
2011-07-27
MANTICORE 101 - Breast (Multidisciplinary Approach to Novel Therapies in Cardiology Oncology Research) is a randomized trial to determine if conventional heart failure pharmacotherapy (angiotensin converting enzyme inhibitor or beta-blocker) can prevent trastuzumab-mediated left ventricular remodeling, measured with cardiac MRI, among patients with HER2+ early breast cancer. One hundred and fifty-nine patients with histologically confirmed HER2+ breast cancer will be enrolled in a parallel 3-arm, randomized, placebo controlled, double-blind design. After baseline assessments, participants will be randomized in a 1:1:1 ratio to an angiotensin-converting enzyme inhibitor (perindopril), beta-blocker (bisoprolol), or placebo. Participants will receive drug or placebo for 1 year beginning 7 days before trastuzumab therapy. Dosages for all groups will be systematically up-titrated, as tolerated, at 1 week intervals for a total of 3 weeks. The primary objective of this randomized clinical trial is to determine if conventional heart failure pharmacotherapy can prevent trastuzumab-mediated left ventricular remodeling among patients with HER2+ early breast cancer, as measured by 12 month change in left ventricular end-diastolic volume using cardiac MRI. Secondary objectives include 1) determine the evolution of left ventricular remodeling on cardiac MRI in patients with HER2+ early breast cancer, 2) understand the mechanism of trastuzumab mediated cardiac toxicity by assessing for the presence of myocardial injury and apoptosis on serum biomarkers and cardiac MRI, and 3) correlate cardiac biomarkers of myocyte injury and extra-cellular matrix remodeling with left ventricular remodeling on cardiac MRI in patients with HER2+ early breast cancer. Cardiac toxicity as a result of cancer therapies is now recognized as a significant health problem of increasing prevalence. To our knowledge, MANTICORE will be the first randomized trial testing proven heart failure pharmacotherapy in the prevention of trastuzumab-mediated cardiotoxicity. We expect the findings of this trial to provide important evidence in the development of guidelines for preventive therapy. ClinicalTrials.gov: NCT01016886.
Novel immunotherapeutic approaches for treatment of infertility.
Abdolmohammadi-Vahid, Samaneh; Danaii, Shahla; Hamdi, Kobra; Jadidi-Niaragh, Farhad; Ahmadi, Majid; Yousefi, Mehdi
2016-12-01
One of the most important reasons of infertility and human reproductive failure is related to uncontrolled immunological response of maternal immune system to early embryo or fetus, that cause rejection of this semi-allograft. Therefore, a tolerance in the immune system is essential to modulate the reactions against the fetus to avoid rejection. The immune system imbalance during implantation or pregnancy may lead to implantation failure or miscarriage. So, use of immunosuppressive or immunomodulator agents can be helpful to prevent immunological attack. Initially, there was a focus on steroids like prednisolone or intralipids in treatment of miscarriage that suppressed the activity of most immune cells, Intravenous Immunoglobulin (IVIG) was then introduced with various mechanisms. Nowadays, novel and specific strategies are established such as monoclonal antibodies and cytokines. More recently, Tacrolimus and Cyclosporine, which were utilized in prevention of transplantation reject, are used as immunosuppressive factors in modulation of immune responses against the fetus. This review is focused on the main immunotherapeutic methods of infertility treatment. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Calcium channel blockers in hypertension. Is there still a controversy?
Izzo, Joseph L
2005-08-01
There are several reasons why no single antihypertensive drug class is ideal in all clinical situations. First, pathophysiologic heterogeneity in hypertension and diversity of mechanisms of antihypertensive drugs dictate that no single drug class can be optimally effective in all subpopulations. Second, sustained blood pressure control generally requires combination therapy to block the reflex stimulation of physiologic mechanisms that attempt to restore blood pressure to pretreatment levels. Third, while effective blood pressure control is more important than choice of initial drug in the prevention of hypertension-related morbidity and mortality, specific drug classes are indicated for optimal treatment of complications of hypertension (e.g. heart failure, kidney disease). Fourth, although antihypertensive drug side effects are uncommon, alternative strategies are required in some patients. Given these principles, past controversies regarding whether calcium channel blockers (CCBs) should be used in the treatment of hypertension become moot. CCBs are extremely effective in lowering blood pressure and in preventing stroke and cardiovascular disease. When additional blood pressure lowering is necessary to meet strict targets, CCBs may be added, even in heart failure or chronic kidney disease, where CCBs alone may not achieve optimal outcomes. Combinations of CCBs with "anti-neurohumoral" drugs such as ACE inhibitors are particularly useful to achieve sustained blood pressure control, reduce adverse effects such as edema, and improve outcomes.
Reliability of large superconducting magnets through design
NASA Astrophysics Data System (ADS)
Henning, C. D.
1981-01-01
Design and quality control of large superconducting magnets for reliability comparable to pressure vessels are discussed. The failure modes are analyzed including thermoelectric instabilities, electrical shorts, cryogenic/vacuum defects, and mechanical malfunctions. Design must take into consideration conductor stability, insulation based on the Paschen curves, and the possible burnout of cryogenic transition leads if the He flow is interrupted. The final stage of the metal drawing process should stress the superconductor material to a stress value higher than the magnet design stress, cabled conductors should be used to achieve mechanical redundancy, and ground-plane insulation must be multilayered for arc prevention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meeuwsen, J.J.; Kling, W.L.; Ploem, W.A.G.A.
1997-01-01
Protection systems in power systems can fail either by not responding when they should (failure to operate) or by operating when they should not (false tripping). The former type of failure is particularly serious since it may result in the isolation of large sections of the network. However, the probability of a failure to operate can be reduced by carrying out preventive maintenance on protection systems. This paper describes an approach to determine the impact of preventive maintenance on protection systems on the reliability of the power supply to customers. The proposed approach is based on Markov models.
Plastic Biliary Stent Occlusion: Factors Involved and Possible Preventive Approaches
Donelli, Gianfranco; Guaglianone, Emilio; Di Rosa, Roberta; Fiocca, Fausto; Basoli, Antonio
2007-01-01
Endoscopic biliary stenting is today the most common palliative treatment for patients suffering from obstructive jaundice associated with malignant hepatobiliary tumors or benign strictures. However, recurrent jaundice, with or without cholangitis, is a major complication of a biliary endoprosthesis insertion. Thus, stent removal and replacement with a new one frequently occurs as a consequence of device blockage caused by microbial biofilm growth and biliary sludge accumulation in the lumen. Factors and mechanisms involved in plastic stent clogging arising from epidemiological, clinical and experimental data, as well as the possible strategies to prevent biliary stent failure, will be reviewed and discussed. PMID:17456835
Post and core build-ups in crown and bridge abutments: Bio-mechanical advantages and disadvantages.
Mamoun, John
2017-06-01
Dentists often place post and core buildups on endodontically treated abutments for crown and bridge restorations. This article analyzes the bio-mechanical purposes, advantages and disadvantages of placing a core or a post and core in an endodontically treated tooth and reviews literature on post and core biomechanics. The author assesses the scientific rationale of the claim that the main purpose of a post is to retain a core, or the claim that posts weaken teeth. More likely, the main function of a post is to help prevent the abutment, on which a crown is cemented, from fracturing such that the abutment separates from the tooth root, at a fracture plane that is located approximately and theoretically at the level of the crown (or ferrule) margin. A post essentially improves the ferrule effect that is provided by the partial fixed denture prosthesis. This paper also explores the difference between bio-mechanical failures of crowns caused by lack of retention or excess taper, versus failures due to a sub-optimal ferrule effect in crown and bridge prostheses.
The Joule heating problem in silver nanowire transparent electrodes
NASA Astrophysics Data System (ADS)
Khaligh, H. H.; Xu, L.; Khosropour, A.; Madeira, A.; Romano, M.; Pradére, C.; Tréguer-Delapierre, M.; Servant, L.; Pope, M. A.; Goldthorpe, I. A.
2017-10-01
Silver nanowire transparent electrodes have shown considerable potential to replace conventional transparent conductive materials. However, in this report we show that Joule heating is a unique and serious problem with these electrodes. When conducting current densities encountered in organic solar cells, the average surface temperature of indium tin oxide (ITO) and silver nanowire electrodes, both with sheet resistances of 60 ohms/square, remains below 35 °C. However, in contrast to ITO, the temperature in the nanowire electrode is very non-uniform, with some localized points reaching temperatures above 250 °C. These hotspots accelerate nanowire degradation, leading to electrode failure after 5 days of continuous current flow. We show that graphene, a commonly used passivation layer for these electrodes, slows nanowire degradation and creates a more uniform surface temperature under current flow. However, the graphene does not prevent Joule heating in the nanowires and local points of high temperature ultimately shift the failure mechanism from nanowire degradation to melting of the underlying plastic substrate. In this paper, surface temperature mapping, lifetime testing under current flow, post-mortem analysis, and modelling illuminate the behaviour and failure mechanisms of nanowires under extended current flow and provide guidelines for managing Joule heating.
Mechanisms of action of sacubitril/valsartan on cardiac remodeling: a systems biology approach.
Iborra-Egea, Oriol; Gálvez-Montón, Carolina; Roura, Santiago; Perea-Gil, Isaac; Prat-Vidal, Cristina; Soler-Botija, Carolina; Bayes-Genis, Antoni
2017-01-01
Sacubitril/Valsartan, proved superiority over other conventional heart failure management treatments, but its mechanisms of action remains obscure. In this study, we sought to explore the mechanistic details for Sacubitril/Valsartan in heart failure and post-myocardial infarction remodeling, using an in silico, systems biology approach. Myocardial transcriptome obtained in response to myocardial infarction in swine was analyzed to address post-infarction ventricular remodeling. Swine transcriptome hits were mapped to their human equivalents using Reciprocal Best (blast) Hits, Gene Name Correspondence, and InParanoid database. Heart failure remodeling was studied using public data available in gene expression omnibus (accession GSE57345, subseries GSE57338), processed using the GEO2R tool. Using the Therapeutic Performance Mapping System technology, dedicated mathematical models trained to fit a set of molecular criteria, defining both pathologies and including all the information available on Sacubitril/Valsartan, were generated. All relationships incorporated into the biological network were drawn from public resources (including KEGG, REACTOME, INTACT, BIOGRID, and MINT). An artificial neural network analysis revealed that Sacubitril/Valsartan acts synergistically against cardiomyocyte cell death and left ventricular extracellular matrix remodeling via eight principal synergistic nodes. When studying each pathway independently, Valsartan was found to improve cardiac remodeling by inhibiting members of the guanine nucleotide-binding protein family, while Sacubitril attenuated cardiomyocyte cell death, hypertrophy, and impaired myocyte contractility by inhibiting PTEN. The complex molecular mechanisms of action of Sacubitril/Valsartan upon post-myocardial infarction and heart failure cardiac remodeling were delineated using a systems biology approach. Further, this dataset provides pathophysiological rationale for the use of Sacubitril/Valsartan to prevent post-infarct remodeling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shade, Ashley
Local diversity (within-sample or alpha diversity) is often implicated as a cause of success or failure of a microbial community. However, the relationships between diversity and emergent properties of a community, such as its stability, productivity or invasibility, are much more nuanced. In this paper, I argue that diversity without context provides limited insights into the mechanisms underpinning community patterns. I provide examples from traditional and microbial ecology to discuss common complications and assumptions about within-sample diversity that may prevent us from digging deeper into the more specific mechanisms underpinning community outcomes. I suggest that measurement of diversity should servemore » as a starting point for further inquiry of ecological mechanisms rather than an 'answer' to community outcomes.« less
Utility-scale system preventive and failure-related maintenance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jennings, C.; Hutchinson, P.
1995-11-01
This paper describes the design and performance background on PVUSA utility-scale systems at Davis and Kerman, California, and reports on a preventative and failure-related maintenance approach and costs.
Alternative approaches to ventilator-associated pneumonia prevention.
Berra, L; Sampson, J; Fumagalli, J; Panigada, M; Kolobow, T
2011-03-01
Ventilator-associated pneumonia (VAP), which develops in patients receiving mechanical ventilation, is the most common nosocomial infection in patients with acute respiratory failure. The major mechanism of lower respiratory tract colonization is aspiration of bacteria-colonized secretions from the oropharynx into the lower airways. The hydrostatic pressure of the secretions that collect in the subglottic space, which is the area above the endotracheal tube (ETT) cuff, or aerosolization of bacteria from the secretions collected within the respiratory tubing may facilitate the leakage into the lower airways. Ideally, the elimination of the mechanisms responsible for aspiration would decrease the incidence of VAP. Several preventive measures have been tested in clinical trials with little success.Here we present the results of our efforts to develop novel approaches for the prevention of VAP. Specifically, we found that keeping ventilated patients in a lateral position, which eliminates gravitational forces, is feasible and possibly advantageous. Additionally, several novel medical devices have been recently developed to prevent bacterial biofilm formation from the ETT and breathing tubing. These devices include coated ETTs, mucus shavers and mucus slurpers. Prevention of ETT bacterial colonization showed decreased bacterial colonization of the respiratory circuit and of the lower respiratory tract in laboratory studies and clinical trials. Future large studies should be designed to test the hypothesis that VAP can be prevented with these novel strategies. While there is a current focus on the use of respiratory devices to prevent biofilm formation and microaspiration, it is important to remember that lower respiratory tract colonization is multifactorial. Prevention of VAP cannot be achieved solely by eliminating bacterial biofilm on respiratory devices, and more comprehensive care of the intubated patient needs to be implemented.
NASA Astrophysics Data System (ADS)
Yang, Dong
Failure of carbon steel boiler tubes from waterside has been reported in the utility boilers and industrial boilers for a long time. In industrial boilers, most waterside tube cracks are found near heavy attachment welds on the outer surface and are typically blunt, with multiple bulbous features indicating a discontinuous growth. These types of tube failures are typically referred to as stress assisted corrosion (SAC). For recovery boilers in the pulp and paper industry, these failures are particularly important as any water leak inside the furnace can potentially lead to smelt-water explosion. Metal properties, environmental variables, and stress conditions are the major factors influencing SAC crack initation and propagation in carbon steel boiler tubes. Slow strain rate tests (SSRT) were conducted under boiler water conditions to study the effect of temperature, oxygen level, and stress conditions on crack initation and propagation on SA-210 carbon steel samples machined out of boiler tubes. Heat treatments were also performed to develop various grain size and carbon content on carbon steel samples, and SSRTs were conducted on these samples to examine the effect of microstructure features on SAC cracking. Mechanisms of SAC crack initation and propagation were proposed and validated based on interrupted slow strain tests (ISSRT). Water chemistry guidelines are provided to prevent SAC and fracture mechanics model is developed to predict SAC failure on industrial boiler tubes.
Expert system for UNIX system reliability and availability enhancement
NASA Astrophysics Data System (ADS)
Xu, Catherine Q.
1993-02-01
Highly reliable and available systems are critical to the airline industry. However, most off-the-shelf computer operating systems and hardware do not have built-in fault tolerant mechanisms, the UNIX workstation is one example. In this research effort, we have developed a rule-based Expert System (ES) to monitor, command, and control a UNIX workstation system with hot-standby redundancy. The ES on each workstation acts as an on-line system administrator to diagnose, report, correct, and prevent certain types of hardware and software failures. If a primary station is approaching failure, the ES coordinates the switch-over to a hot-standby secondary workstation. The goal is to discover and solve certain fatal problems early enough to prevent complete system failure from occurring and therefore to enhance system reliability and availability. Test results show that the ES can diagnose all targeted faulty scenarios and take desired actions in a consistent manner regardless of the sequence of the faults. The ES can perform designated system administration tasks about ten times faster than an experienced human operator. Compared with a single workstation system, our hot-standby redundancy system downtime is predicted to be reduced by more than 50 percent by using the ES to command and control the system.
Expert System for UNIX System Reliability and Availability Enhancement
NASA Technical Reports Server (NTRS)
Xu, Catherine Q.
1993-01-01
Highly reliable and available systems are critical to the airline industry. However, most off-the-shelf computer operating systems and hardware do not have built-in fault tolerant mechanisms, the UNIX workstation is one example. In this research effort, we have developed a rule-based Expert System (ES) to monitor, command, and control a UNIX workstation system with hot-standby redundancy. The ES on each workstation acts as an on-line system administrator to diagnose, report, correct, and prevent certain types of hardware and software failures. If a primary station is approaching failure, the ES coordinates the switch-over to a hot-standby secondary workstation. The goal is to discover and solve certain fatal problems early enough to prevent complete system failure from occurring and therefore to enhance system reliability and availability. Test results show that the ES can diagnose all targeted faulty scenarios and take desired actions in a consistent manner regardless of the sequence of the faults. The ES can perform designated system administration tasks about ten times faster than an experienced human operator. Compared with a single workstation system, our hot-standby redundancy system downtime is predicted to be reduced by more than 50 percent by using the ES to command and control the system.
Role of failure-mechanism identification in accelerated testing
NASA Technical Reports Server (NTRS)
Hu, J. M.; Barker, D.; Dasgupta, A.; Arora, A.
1993-01-01
Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.
Levosimendan Prevents Pressure-Overload-induced Right Ventricular Failure.
Hillgaard, Thomas Krarup; Andersen, Asger; Andersen, Stine; Vildbrad, Mads D; Ringgaard, Steffen; Nielsen, Jan M; Nielsen-Kudsk, Jens E
2016-04-01
We investigated if chronic levosimendan treatment can prevent and revert pressure-overload-induced right ventricular hypertrophy and failure in rats. Right ventricular hypertrophy and failure was induced in Wistar rats by pulmonary trunk banding (PTB). The PTB rats were treated with levosimendan (3 mg·kg·d) 3 days before surgery [n = 10, prevention (PREV)], 3 weeks after surgery [n = 10, reversal (REV)] or vehicle (n = 10, VEH). Sham-operated rats received vehicle (n = 16, SHAM). Right ventricular function was evaluated 7 weeks after surgery by echocardiography, magnetic resonance imaging, pressure-volume relations, gross anatomy, and histology. PTB induced right ventricular hypertrophy and compensated heart failure evident by reduced cardiac index (CI) without extra cardiac signs of heart failure. Levosimendan treatment prevented deterioration of right ventricular function measured by CI and right ventricular ejection fraction (RVEF) (CI: VEH vs. PREV 281 ± 17 vs. 362 ± 34 mL·min·kg, P ≤ 0.05, RVEF: VEH vs. PREV 57 ± 2% vs. 68 ± 3%, P ≤ 0.01) to values similar to SHAM (CI: 345 ± 21 mL·min·kg, RVEF: 71 ± 2%). RV contractility was improved in the REV group measured by preload recruitable stroke work (VEH vs. REV 39 ± 3 vs. 66 ± 10 mmHg P ≤ 0.05). Chronic treatment with levosimendan prevents the development of right ventricular failure and improves contractility in established pressure-overload-induced right ventricular failure.
Structure‐function relationships at the human spinal disc‐vertebra interface
Berg‐Johansen, Britta; Fields, Aaron J.; Liebenberg, Ellen C.; Li, Alfred
2017-01-01
ABSTRACT Damage at the intervertebral disc‐vertebra interface associates with back pain and disc herniation. However, the structural and biomechanical properties of the disc‐vertebra interface remain underexplored. We sought to measure mechanical properties and failure mechanisms, quantify architectural features, and assess structure‐function relationships at this vulnerable location. Vertebra‐disc‐vertebra specimens from human cadaver thoracic spines were scanned with micro‐computed tomography (μCT), surface speckle‐coated, and loaded to failure in uniaxial tension. Digital image correlation (DIC) was used to calculate local surface strains. Failure surfaces were scanned using scanning electron microscopy (SEM), and adjacent sagittal slices were analyzed with histology and SEM. Seventy‐one percent of specimens failed initially at the cartilage endplate‐bone interface of the inner annulus region. Histology and SEM both indicated a lack of structural integration between the cartilage endplate (CEP) and bone. The interface failure strength was increased in samples with higher trabecular bone volume fraction in the vertebral endplates. Furthermore, failure strength decreased with degeneration, and in discs with thicker CEPs. Our findings indicate that poor structural connectivity between the CEP and vertebra may explain the structural weakness at this region, and provide insight into structural features that may contribute to risk for disc‐vertebra interface injury. The disc‐vertebra interface is the site of failure in the majority of herniation injuries. Here we show new structure‐function relationships at this interface that may motivate the development of diagnostics, prevention strategies, and treatments to improve the prognosis for many low back pain patients with disc‐vertebra interface injuries. © 2017 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 36:192–201, 2018. PMID:28590060
Evolving Role of Natriuretic Peptides from Diagnostic Tool to Therapeutic Modality.
Pagel-Langenickel, Ines
2018-01-01
Natriuretic peptides (NP) are widely recognized as key regulators of blood pressure, water and salt homeostasis. In addition, they play a critical role in physiological cardiac growth and mediate a variety of biological effects including antiproliferative and anti-inflammatory effects in other organs and tissues. The cardiac release of NPs ANP and BNP represents an important compensatory mechanism during acute and chronic cardiac overload and during the pathogenesis of heart failure where their actions counteract the sustained activation of renin-angiotensin-aldosterone and other neurohormonal systems. Elevated circulating plasma NP levels correlate with the severity of heart failure and particularly BNP and the pro-peptide, NT-proBNP have been established as biomarkers for the diagnosis of heart failure as well as prognostic markers for cardiovascular risk. Despite activation of the NP system in heart failure it is inadequate to prevent progressive fluid and sodium retention and cardiac remodeling. Therapeutic approaches included administration of synthetic peptide analogs and the inhibition of NP-degrading enzyme neutral endopeptidase (NEP). Of all strategies only the combined NEP/ARB inhibition with sacubitril/valsartan had shown clinical success in reducing cardiovascular mortality and morbidity in patients with heart failure.
Levy, Matthew; Oyenuga, Olusegun
2015-01-01
Fibrotic lung diseases carry a significant mortality burden worldwide. A large proportion of these deaths are due to right heart failure and pulmonary hypertension. Underlying contributory factors which appear to play a role in the mechanism of progression of right heart dysfunction include chronic hypoxia, defective calcium handling, hyperaldosteronism, pulmonary vascular alterations, cyclic strain of pressure and volume changes, elevation of circulating TGF-β, and elevated systemic NO levels. Specific therapies targeting pulmonary hypertension include calcium channel blockers, endothelin (ET-1) receptor antagonists, prostacyclin analogs, phosphodiesterase type 5 (PDE5) inhibitors, and rho-kinase (ROCK) inhibitors. Newer antifibrotic and anti-inflammatory agents may exert beneficial effects on heart failure in idiopathic pulmonary fibrosis. Furthermore, right ventricle-targeted therapies, aimed at mitigating the effects of functional right ventricular failure, include β-adrenoceptor (β-AR) blockers, angiotensin-converting enzyme (ACE) inhibitors, antioxidants, modulators of metabolism, and 5-hydroxytryptamine-2B (5-HT2B) receptor antagonists. Newer nonpharmacologic modalities for right ventricular support are increasingly being implemented. Early, effective, and individualized therapy may prevent overt right heart failure in fibrotic lung disease leading to improved outcomes and quality of life. PMID:26583148
Understanding Lymphatic Valve Function via Computational Modeling
NASA Astrophysics Data System (ADS)
Wolf, Ki; Nepiyushchikh, Zhanna; Razavi, Mohammad; Dixon, Brandon; Alexeev, Alexander
2017-11-01
The lymphatic system is a crucial part to the circulatory system with many important functions, such as transport of interstitial fluid, fatty acid, and immune cells. Lymphatic vessels' contractile walls and valves allow lymph flow against adverse pressure gradients and prevent back flow. Yet, the effect of lymphatic valves' geometric and mechanical properties to pumping performance and lymphatic dysfunctions like lymphedema is not well understood. Our coupled fluid-solid computational model based on lattice Boltzmann model and lattice spring model investigates the dynamics and effectiveness of lymphatic valves in resistance minimization, backflow prevention, and viscoelastic response under different geometric and mechanical properties, suggesting the range of lymphatic valve parameters with effective pumping performance. Our model also provides more physiologically relevant relations of the valve response under varied conditions to a lumped parameter model of the lymphatic system giving an integrative insight into lymphatic system performance, including its failure due to diseases. NSF CMMI-1635133.
Cytotoxic and Antitumor Activity of Sulforaphane: The Role of Reactive Oxygen Species
Sestili, Piero
2015-01-01
According to recent estimates, cancer continues to remain the second leading cause of death and is becoming the leading one in old age. Failure and high systemic toxicity of conventional cancer therapies have accelerated the identification and development of innovative preventive as well as therapeutic strategies to contrast cancer-associated morbidity and mortality. In recent years, increasing body of in vitro and in vivo studies has underscored the cancer preventive and therapeutic efficacy of the isothiocyanate sulforaphane. In this review article, we highlight that sulforaphane cytotoxicity derives from complex, concurring, and multiple mechanisms, among which the generation of reactive oxygen species has been identified as playing a central role in promoting apoptosis and autophagy of target cells. We also discuss the site and the mechanism of reactive oxygen species' formation by sulforaphane, the toxicological relevance of sulforaphane-formed reactive oxygen species, and the death pathways triggered by sulforaphane-derived reactive oxygen species. PMID:26185755
Influence of Physical Activity on Hypertension and Cardiac Structure and Function
Hegde, Sheila M.; Solomon, Scott D.
2015-01-01
The global burden of hypertension is rising and accounts for substantial morbidity and mortality. Lifestyle factors such as diet and physical inactivity contribute to this burden, further highlighting the need for prevention efforts to curb this public health epidemic. Regular physical activity is associated with lower blood pressure, reduced cardiovascular risk, and cardiac remodeling. While exercise and hypertension can both be associated with the development of left ventricular hypertrophy (LVH), the cardiac remodeling from hypertension is pathologic with an associated increase in myocyte hypertrophy, fibrosis, and risk of heart failure and mortality, whereas LVH in athletes is generally non-pathologic and lacks the fibrosis seen in hypertension. In hypertensive patients, physical activity has been associated with paradoxical regression or prevention of LVH, suggesting a mechanism by which exercise can benefit hypertensive patients. Further studies are needed to better understand the mechanisms underlying the benefits of physical activity in the hypertensive heart. PMID:26277725
Packer, Milton
2018-03-22
Most treatments for chronic heart failure are effective both in preventing its onset and reducing its progression. However, statins prevent the development of heart failure, but they do not decrease morbidity and mortality in those with established heart failure. This apparent discordance cannot be explained by an effect to prevent interval myocardial infarctions. Instead, it seems that the disease that statins were preventing in trials of patients with a metabolic disorder was different from the disease that they were treating in trials of chronic heart failure. The most common phenotype of heart failure in patients with obesity and diabetes is heart failure with a preserved ejection fraction (HFpEF). In this disorder, the anti-inflammatory effects of statins might ameliorate myocardial fibrosis and cardiac filling abnormalities, but these actions may have little relevance to patients with heart failure and a reduced ejection fraction (HFrEF), whose primary derangement is cardiomyocyte loss and stretch. These distinctions may explain why statins were ineffective in trials that focused on HFrEF, but have been reported to produce with favourable effects in observational studies of HFpEF. Similarly, selective cytokine antagonists were ineffective in HFrEF, but have been associated with benefits in HFpEF. These observations may have important implications for our understanding of the effects of antihyperglycaemic medications. Glucagon-like peptide-1 receptor agonists have had neutral effects on heart failure events in people at risk for HFpEF, but have exerted deleterious actions in HFrEF. Similarly, sodium-glucose co-transporter 2 inhibitors, which exert anti-inflammatory effects and reduce heart failure events in patients who are prone to HFpEF, may not be effective in HFrEF. The distinctions between HFrEF and HFpEF may explain why the effects of drugs on heart failure events in diabetes trials may not be relevant to their use in patients with systolic dysfunction. © 2018 The Authors. European Journal of Heart Failure © 2018 European Society of Cardiology.
Mechanical Circulatory Support Devices for Acute Right Ventricular Failure.
Kapur, Navin K; Esposito, Michele L; Bader, Yousef; Morine, Kevin J; Kiernan, Michael S; Pham, Duc Thinh; Burkhoff, Daniel
2017-07-18
Right ventricular (RV) failure remains a major cause of global morbidity and mortality for patients with advanced heart failure, pulmonary hypertension, or acute myocardial infarction and after major cardiac surgery. Over the past 2 decades, percutaneously delivered acute mechanical circulatory support pumps specifically designed to support RV failure have been introduced into clinical practice. RV acute mechanical circulatory support now represents an important step in the management of RV failure and provides an opportunity to rapidly stabilize patients with cardiogenic shock involving the RV. As experience with RV devices grows, their role as mechanical therapies for RV failure will depend less on the technical ability to place the device and more on improved algorithms for identifying RV failure, patient monitoring, and weaning protocols for both isolated RV failure and biventricular failure. In this review, we discuss the pathophysiology of acute RV failure and both the mechanism of action and clinical data exploring the utility of existing RV acute mechanical circulatory support devices. © 2017 American Heart Association, Inc.
Otero, D Peña; Domínguez, D Vazquez; Fernández, L Hernanz; Magariño, A Santano; González, V Jimenez; Klepzing, J V García; Montesinos, J V Beneit
2017-03-02
To comparatively assess the efficacy of four different therapeutic strategies to prevent the development of facial pressure ulcers (FPUs) related to the use of non-invasive mechanical ventilation (NIV) with oro-nasal masks in critically ill hospitalised patients. This randomised control trial was performed at the high dependency unit in the University General Hospital Gregorio Marañón in Madrid, Spain. Overall, 152 patients with acute respiratory failure were recruited. All patients were hospitalised and received NIV through oro-nasal masks. The Norton tool was used to evaluate the general risk of developing pressure ulcers (PUs). Subjects were divided into four groups, each of them receiving a different treatment. Tissue assessment and preventive care were performed by a member of the research team. The incidence of FPUs was significantly lower in the group receiving a solution of hyperoxygenated fatty acids (HOFA) when compared with each of the other therapeutic strategies: direct mask (p=0.055), adhesive thin dressing (p=0.03) and adhesive foam dressing (p<0.001). The application of HOFA on the facial skin in contact with the oro-nasal masks showed the highest efficacy in the prevention of NIV-related FPUs.
Facts about Chickenpox and Shingles for Adults
... heart failure, heart attack, type II diabetes and major depression. Prevention Chickenpox can be prevented by vaccination. Children ... heart failure, heart attack, type II diabetes and major depression. Antiviral medications can be used to treat shingles ...
Global Failure Modes in Composite Structures
NASA Technical Reports Server (NTRS)
Knauss, W. G.; Gonzalez, Luis
2001-01-01
Composite materials provide well-known advantages for space and aeronautical applications in terms of strength and rigidity to weight ratios and other mechanical properties. As a consequence, their use has experienced a constant increase in the past decades and it is anticipated that this trend will be maintained in the near future. At the same time, being these materials relatively new compared to metals, and having failure characteristics completely different from them, their damage growth and their failure mechanisms are not as well understood in a predictive sense. For example, while in metals fracture produces "clean" cracks with their well defined analytically stress fields at the crack tip, composite fracture is a more complex phenomenon. Instead of a crack, we confront a "damage zone" that may include fiber breakage, fiber microbuckling, fiber pullout, matrix cracking, delamination, debonding or any combination of all these different mechanisms. These phenomena are prevalent in any failure process through an aircraft structure, whether one addresses a global failure such as the ripping of a fuselage or wing section, or whether one is concerned with the failure initiation near a thickness change at stringers or other reinforcement. Thus the topic that has been under consideration has wide application in any real structure and is considered an essential contribution to the predictive failure analysis capability for aircraft containing composite components. The heterogeneity and the anisotropy of composites are not only advantageous but essential characteristics, yet these same features provide complex stress fields, especially in the presence of geometrical discontinuities such as notches, holes or cutouts or structural elements such as stiffeners, stringers, etc. To properly address the interaction between a damage/crack front and a hole with a stringer it is imperative that the stress and deformation fields of the former be (sufficiently well) characterized. The question of "scaling" is an essential concern in any structural materials investigation. For example, experiments in the past have shown that the "strength" of a composite depends on hole size. As a consequence the validity of traditional fracture mechanics concepts applied to composite materials failure must be questioned. The size of the fibers, the dimensions of the laminae, etc. together with the fact that, because of the layered anisotropy, the stress field is no longer two-dimensional, prevent the otherwise obviously confident use of "similarity concepts". Therefore, the question needs to be raised of whether in composites "size matters or not", i.e., whether the results obtained in a laboratory using small coupons are truly representative of the situation involving a full scale component.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-09
... failure of a first stage turbine disk that had a metallurgical defect. This AD requires inspecting certain...-1. We are issuing this AD to prevent uncontained failure of the first stage turbine disk and damage... failure of a first stage turbine disk that had a metallurgical defect. We are issuing this AD to prevent...
Vibration monitoring via nano-composite piezoelectric foam bushings
NASA Astrophysics Data System (ADS)
Bird, Evan T.; Merrell, A. Jake; Anderson, Brady K.; Newton, Cory N.; Rosquist, Parker G.; Fullwood, David T.; Bowden, Anton E.; Seeley, Matthew K.
2016-11-01
Most mechanical systems produce vibrations as an inherent side effect of operation. Though some vibrations are acceptable in operation, others can cause damage or signal a machine’s imminent failure. These vibrations would optimally be monitored in real-time, without human supervision to prevent failure and excessive wear in machinery. This paper explores a new alternative to currently-used machine-monitoring equipment, namely a piezoelectric foam sensor system. These sensors are made of a silicone-based foam embedded with nano- and micro-scale conductive particles. Upon impact, they emit an electric response that is directly correlated with impact energy, with no electrical power input. In the present work, we investigated their utility as self-sensing bushings on machinery. These sensors were found to accurately detect both the amplitude and frequency of typical machine vibrations. The bushings could potentially save time and money over other vibration sensing mechanisms, while simultaneously providing a potential control input that could be utilized for correcting vibrational imbalance.
NASA Astrophysics Data System (ADS)
Milani, Gabriele; Shehu, Rafael; Valente, Marco
2017-11-01
This paper investigates the effectiveness of reducing the seismic vulnerability of masonry towers by means of innovative and traditional strengthening techniques. The followed strategy for providing the optimal retrofitting for masonry towers subjected to seismic risk relies on preventing active failure mechanisms. These vulnerable mechanisms are pre-assigned failure patterns based on the crack patterns experienced during the past seismic events. An upper bound limit analysis strategy is found suitable to be applied for simplified tower models in their present state and the proposed retrofitted ones. Taking into consideration the variability of geometrical features and the uncertainty of the strengthening techniques, Monte Carlo simulations are implemented into the limit analysis. In this framework a wide range of idealized cases are covered by the conducted analyses. The retrofitting strategies aim to increase the shear strength and the overturning load carrying capacity in order to reduce vulnerability. This methodology gives the possibility to use different materials which can fulfill the structural implementability requirements.
Some Aspects of the Failure Mechanisms in BaTiO3-Based Multilayer Ceramic Capacitors
NASA Technical Reports Server (NTRS)
Liu, David Donhang; Sampson, Michael J.
2012-01-01
The objective of this presentation is to gain insight into possible failure mechanisms in BaTiO3-based ceramic capacitors that may be associated with the reliability degradation that accompanies a reduction in dielectric thickness, as reported by Intel Corporation in 2010. The volumetric efficiency (microF/cm3) of a multilayer ceramic capacitor (MLCC) has been shown to not increase limitlessly due to the grain size effect on the dielectric constant of ferroelectric ceramic BaTiO3 material. The reliability of an MLCC has been discussed with respect to its structure. The MLCCs with higher numbers of dielectric layers will pose more challenges for the reliability of dielectric material, which is the case for most base-metal-electrode (BME) capacitors. A number of MLCCs manufactured using both precious-metal-electrode (PME) and BME technology, with 25 V rating and various chip sizes and capacitances, were tested at accelerated stress levels. Most of these MLCCs had a failure behavior with two mixed failure modes: the well-known rapid dielectric wearout, and so-called 'early failures." The two failure modes can be distinguished when the testing data were presented and normalized at use-level using a 2-parameter Weibull plot. The early failures had a slope parameter of Beta >1, indicating that the early failures are not infant mortalities. Early failures are triggered due to external electrical overstress and become dominant as dielectric layer thickness decreases, accompanied by a dramatic reduction in reliability. This indicates that early failures are the main cause of the reliability degradation in MLCCs as dielectric layer thickness decreases. All of the early failures are characterized by an avalanche-like breakdown leakage current. The failures have been attributed to the extrinsic minor construction defects introduced during fabrication of the capacitors. A reliability model including dielectric thickness and extrinsic defect feature size is proposed in this presentation. The model can be used to explain the Intel-reported reliability degradation in MLCCs with respect to the reduction of dielectric thickness. It can also be used to estimate the reliability of a MLCC based on its construction and microstructure parameters such as dielectric thickness, average grain size, and number of dielectric layers. Measures for preventing early failures are also discussed in this document.
Data-Driven Packet Loss Estimation for Node Healthy Sensing in Decentralized Cluster
Fan, Hangyu; Wang, Huandong; Li, Yong
2018-01-01
Decentralized clustering of modern information technology is widely adopted in various fields these years. One of the main reason is the features of high availability and the failure-tolerance which can prevent the entire system form broking down by a failure of a single point. Recently, toolkits such as Akka are used by the public commonly to easily build such kind of cluster. However, clusters of such kind that use Gossip as their membership managing protocol and use link failure detecting mechanism to detect link failures cannot deal with the scenario that a node stochastically drops packets and corrupts the member status of the cluster. In this paper, we formulate the problem to be evaluating the link quality and finding a max clique (NP-Complete) in the connectivity graph. We then proposed an algorithm that consists of two models driven by data from application layer to respectively solving these two problems. Through simulations with statistical data and a real-world product, we demonstrate that our algorithm has a good performance. PMID:29360792
Zakkar, Mustafa; Kanagasabay, Robin; Hunt, Ian
2014-04-01
A best evidence topic in cardiothoracic surgery was written according to a structured protocol. The question addressed was whether manual closure of the bronchial stump is safer with lower failure rates than mechanical closure using a stapling device following anatomical lung resection. One hundred and twenty-nine papers were identified using the search below. Eight papers presented the best evidence to answer the clinical question as they included sufficient number of patients to reach conclusions regarding the issues of interest for this review. Complications, complication rates and operation time were included in the assessment. The author, journal, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of the papers are tabulated. When looking at manual vs mechanical staples, it was noted that stapler failure can occur in around 4% of cases. The rate of bronchopleural fistula (BPF) development varied more in patients who underwent manual closure (1.5-12.5%) than in patients who underwent mechanical closure (1-5.7%). Although most of the studies reviewed showed no statistical differences between manual and mechanical closure in terms of BPF development, one study, however, showed that manual closure was significantly associated with lower numbers of postoperative BPF, while another study showed that mechanical closure is significantly associated with lower incidence of BPF. When looking at the role of the learning curve and training opportunities, it seems that the surgeon's inexperience when using mechanical staples can contribute to BPF development. A surgeon's experience can play a major role in the prevention of BPF development in patients having manual closure. Manual closure can provide a cheap and reliable technique when compared with costs incurred from using staplers, it is applicable in all situations and can be taught to surgeons in training with an acceptable risk. However, there is a lack of evidence to suggest that manual closure is better than mechanical stapler closure following anatomical lung resection.
[Early detection, prevention and management of renal failure in liver transplantation].
Castells, Lluís; Baliellas, Carme; Bilbao, Itxarone; Cantarell, Carme; Cruzado, Josep Maria; Esforzado, Núria; García-Valdecasas, Juan Carlos; Lladó, Laura; Rimola, Antoni; Serón, Daniel; Oppenheimer, Federico
2014-10-01
Renal failure is a frequent complication in liver transplant recipients and is associated with increased morbidity and mortality. A variety of risk factors for the development of renal failure in the pre- and post-transplantation periods have been described, as well as at the time of surgery. To reduce the negative impact of renal failure in this population, an active approach is required for the identification of those patients with risk factors, the implementation of preventive strategies, and the early detection of progressive deterioration of renal function. Based on published evidence and on clinical experience, this document presents a series of recommendations on monitoring RF in LT recipients, as well as on the prevention and management of acute and chronic renal failure after LT and referral of these patients to the nephrologist. In addition, this document also provides an update of the various immunosuppressive regimens tested in this population for the prevention and control of post-transplantation deterioration of renal function. Copyright © 2013 Elsevier España, S.L.U. and AEEH y AEG. All rights reserved.
Humanitarian responses to mass violence perpetrated against vulnerable populations.
Gellert, G. A.
1995-01-01
This multidisciplinary review links three areas of legitimate inquiry for practitioners of medicine and public health. The first is occurrences of mass violence or genocide perpetrated against vulnerable populations, with a focus on the failure of national and international mechanisms to prevent or predict such violence. The second is evolving concepts of national sovereignty and an emerging framework in which the imperative to assist vulnerable populations supersedes a state's right to self determination. The last is how medical, public health, and other systems of surveillance and rapid assessment of mass violence can accelerate public awareness and facilitate structured, consistent political decision making to prevent mass violence and to provide international humanitarian assistance. Images p1000-a PMID:7580643
Ghodsizad, Ali; Koerner, Michael M; Brehm, Christoph E; El-Banayosy, Aly
2014-05-01
In advanced cardiogenic shock, early mechanical circulatory support may prevent multiorgan failure and death. In this article, we are describing our experience with extracorporeal membrane oxygenation (ECMO) application. Venoarterial ECMO has been used successfully as a therapeutic option for patients with advanced cardiogenic shock and cardiac arrest. In this review, based on the daily routine of the Hershey group using ECMO for therapy of advanced cardiogenic shock, the application of ECMO is described. The aim is to share our hands-on experience during emergent implantation and to contribute to the knowledge within the field of mechanical circulatory support.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolenbaugh, Jonathan M.; Naqi, Syed
A method to operate a clutch device in an electro-mechanical transmission mechanically-operatively coupled to an internal combustion engine and at least one electric machine includes, in response to a failure condition detected within a flow control device configured to facilitate flow of hydraulic fluid for operating the clutch device, selectively preventing the flow of hydraulic fluid from entering the flow control device and feeding the clutch device. Synchronization of the clutch device is initiated when the clutch device is intended for activation, and only if the clutch device is synchronized, the flow of hydraulic fluid is selectively permitted to entermore » the flow control device to activate the clutch device.« less
Dual output variable pitch turbofan actuation system
NASA Technical Reports Server (NTRS)
Griswold, R. H., Jr.; Broman, C. L. (Inventor)
1976-01-01
An improved actuating mechanism was provided for a gas turbine engine incorporating fan blades of the variable pitch variety, the actuator adapted to rotate the individual fan blades within apertures in an associated fan disc. The actuator included means such as a pair of synchronizing ring gears, one on each side of the blade shanks, and adapted to engage pinions disposed thereon. Means were provided to impart rotation to the ring gears in opposite directions to effect rotation of the blade shanks in response to a predetermined input signal. In the event of system failure, a run-away actuator was prevented by an improved braking device which arrests the mechanism.
Valenzuela, Nicole M; Reed, Elaine F
2017-06-30
Solid organ transplantation is a curative therapy for hundreds of thousands of patients with end-stage organ failure. However, long-term outcomes have not improved, and nearly half of transplant recipients will lose their allografts by 10 years after transplant. One of the major challenges facing clinical transplantation is antibody-mediated rejection (AMR) caused by anti-donor HLA antibodies. AMR is highly associated with graft loss, but unfortunately there are few efficacious therapies to prevent and reverse AMR. This Review describes the clinical and histological manifestations of AMR, and discusses the immunopathological mechanisms contributing to antibody-mediated allograft injury as well as current and emerging therapies.
Manolagas, Stavros C.; Parfitt, A. Michael
2010-01-01
The adverse effects of aging of other organs (ovaries at menopause) on the skeleton are well known, but ironically little is known of skeletal aging itself. Evidence indicates that age-related changes, such as oxidative stress, are fundamental mechanisms of the decline of bone mass and strength. Unlike the short-lived osteoclasts and osteoblasts, osteocytes— former osteoblasts entombed in the mineralized matrix— live as long as 50 years, and their death is dependent on skeletal age. Osteocyte death is a major contributor to the decline of bone strength with age, and the likely mechanisms are oxidative stress, autophagy failure, and nuclear pore “leakiness.” Unraveling these mechanisms should improve understanding of the age-related increase in fractures and suggest novel targets for its prevention. PMID:20223679
Diversity is the question, not the answer
Shade, Ashley
2016-09-16
Local diversity (within-sample or alpha diversity) is often implicated as a cause of success or failure of a microbial community. However, the relationships between diversity and emergent properties of a community, such as its stability, productivity or invasibility, are much more nuanced. In this paper, I argue that diversity without context provides limited insights into the mechanisms underpinning community patterns. I provide examples from traditional and microbial ecology to discuss common complications and assumptions about within-sample diversity that may prevent us from digging deeper into the more specific mechanisms underpinning community outcomes. I suggest that measurement of diversity should servemore » as a starting point for further inquiry of ecological mechanisms rather than an 'answer' to community outcomes.« less
Plasma membrane repair in plants.
Schapire, Arnaldo L; Valpuesta, Victoriano; Botella, Miguel A
2009-12-01
Resealing is the membrane-repair process that enables cells to survive disruption, preventing the loss of irreplaceable cell types and eliminating the cost of replacing injured cells. Given that failure in the resealing process in animal cells causes diverse types of muscular dystrophy, plasma membrane repair has been extensively studied in these systems. Animal proteins with Ca(2+)-binding domains such as synaptotagmins and dysferlin mediate Ca(2+)-dependent exocytosis to repair plasma membranes after mechanical damage. Until recently, no components or proof for membrane repair mechanisms have been discovered in plants. However, Arabidopsis SYT1 is now the first plant synaptotagmin demonstrated to participate in Ca(2+)-dependent repair of membranes. This suggests a conservation of membrane repair mechanisms between animal and plant cells.
The human subject: an integrative animal model for 21st century heart failure research
Chandrasekera, P Charukeshi; Pippin, John J
2015-01-01
Heart failure remains a leading cause of death and it is a major cause of morbidity and mortality affecting tens of millions of people worldwide. Despite decades of extensive research conducted at enormous expense, only a handful of interventions have significantly impacted survival in heart failure. Even the most widely prescribed treatments act primarily to slow disease progression, do not provide sustained survival advantage, and have adverse side effects. Since mortality remains about 50% within five years of diagnosis, the need to increase our understanding of heart failure disease mechanisms and development of preventive and reparative therapies remains critical. Currently, the vast majority of basic science heart failure research is conducted using animal models ranging from fruit flies to primates; however, insights gleaned from decades of animal-based research efforts have not been proportional to research success in terms of deciphering human heart failure and developing effective therapeutics for human patients. Here we discuss the reasons for this translational discrepancy which can be equally attributed to the use of erroneous animal models and the lack of widespread use of human-based research methodologies and address why and how we must position our own species at center stage as the quintessential animal model for 21st century heart failure research. If the ultimate goal of the scientific community is to tackle the epidemic status of heart failure, the best way to achieve that goal is through prioritizing human-based, human-relevant research. PMID:26550463
Rickard, Claire M; Marsh, Nicole M; Webster, Joan; Gavin, Nicole C; Chan, Raymond J; McCarthy, Alexandra L; Mollee, Peter; Ullman, Amanda J; Kleidon, Tricia; Chopra, Vineet; Zhang, Li; McGrail, Matthew R; Larsen, Emily; Choudhury, Md Abu; Keogh, Samantha; Alexandrou, Evan; McMillan, David J; Mervin, Merehau Cindy; Paterson, David L; Cooke, Marie; Ray-Barruel, Gillian; Castillo, Maria Isabel; Hallahan, Andrew; Corley, Amanda; Geoffrey Playford, E
2017-06-15
Around 30% of peripherally inserted central catheters (PICCs) fail from vascular, infectious or mechanical complications. Patients with cancer are at highest risk, and this increases morbidity, mortality and costs. Effective PICC dressing and securement may prevent PICC failure; however, no large randomised controlled trial (RCT) has compared alternative approaches. We designed this RCT to assess the clinical and cost-effectiveness of dressing and securements to prevent PICC failure. Pragmatic, multicentre, 2×2 factorial, superiority RCT of (1) dressings (chlorhexidine gluconate disc (CHG) vs no disc) and (2) securements (integrated securement dressing (ISD) vs securement device (SED)). A qualitative evaluation using a knowledge translation framework is included. Recruitment of 1240 patients will occur over 3 years with allocation concealment until randomisation by a centralised service. For the dressing hypothesis, we hypothesise CHG discs will reduce catheter-associated bloodstream infection (CABSI) compared with no CHG disc. For the securement hypothesis, we hypothesise that ISD will reduce composite PICC failure (infection (CABSI/local infection), occlusion, dislodgement or thrombosis), compared with SED. types of PICC failure; safety; costs; dressing/securement failure; dwell time; microbial colonisation; reversible PICC complications and consumer acceptability. Relative incidence rates of CABSI and PICC failure/100 devices and/1000 PICC days (with 95% CIs) will summarise treatment impact. Kaplan-Meier survival curves (and log rank Mantel-Haenszel test) will compare outcomes over time. Secondary end points will be compared between groups using parametric/non-parametric techniques; p values <0.05 will be considered to be statistically significant. Ethical approval from Queensland Health (HREC/15/QRCH/241) and Griffith University (Ref. No. 2016/063). Results will be published. Trial registration number is: ACTRN12616000315415. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
[Analogies between heart and respiratory muscle failure. Importance to clinical practice].
Köhler, D
2009-01-01
Heart failure is an established diagnosis. Respiratory muscle or ventilatory pump failure, however, is less well known. The latter becomes obvious through hypercapnia, caused by hypoventilation. The respiratory centre tunes into hypercapnea in order to prevent the danger of respiratory muscle overload (hypercapnic ventilatory failure). Hypoventilation will consecutively cause hypoxemia but this will not be responsible for performance limitation. One therefore has to distinguish primary hypoxemia evolving from diseases in the lung parenchyma. Here hypoxemia is the key feature and compensatory hyperventilation usually decreases PaCO2 levels. The cardiac as well as the respiratory pump adapt to an inevitable burden caused by chronic disease. In either case organ muscle mass will increase. If the burden exceeds the range of possible physiological adaptation, compensatory mechanisms will set in that are similar in both instances. During periods of overload either muscle system is mainly fueled by muscular glycogen. In the recovery phase (e. g. during sleep) stores are replenished, which can be recognized by down-regulation of the blood pressure in case of the cardiac pumb or by augmentation of hypercapnia through hypoventilation in case of the respiratory pump. The main function of cardiac and respiratory pump is maintenance of oxygen transport. The human body has developed certain compensatory mechanisms to adapt to insufficient oxygen supply especially during periods of overload. These mechanisms include shift of the oxygen binding curve, expression of respiratory chain isoenzymes capable of producing ATP at lower partial pressures of oxygen and the development of polyglobulia. Medically or pharmacologically the cardiac pump can be unloaded with beta blockers, the respiratory pump by application of inspired oxygen. Newer forms of therapy augment the process of recovery. The heart can be supported through bypass surgery or intravascular pump systems, while respiratory muscles may be supported through elective ventilatory support (mainly non-invasive) in the patient's home. The latter treatment in particular will increase patient endurance and quality of life and decrease mortality. Heart and respiratory pump failure share many common features. Since both take care of oxygen supply to the body, their function and compensatory mechanisms are closely related and linked.
[Acute heart failure: precipitating factors and prevention].
Aramburu Bodas, Oscar; Conde Martel, Alicia; Salamanca Bautista, Prado
2014-03-01
Acute heart failure episodes, whether onset or decompensation of a chronic form, are most often precipitated by a concurrent process or disease, described as precipitating factors of heart failure. In this article, we review these precipitating factors, their proportions and clinical relevance in general and in subgroups of patients, their relationship with prognosis, and their possible prevention. Copyright © 2014 Elsevier España, S.L. All rights reserved.
Environmental testing to prevent on-orbit TDRS failures
NASA Technical Reports Server (NTRS)
Cutler, Robert M.
1994-01-01
Can improved environmental testing prevent on-orbit component failures such as those experienced in the Tracking and Data Relay Satellite (TDRS) constellation? TDRS communications have been available to user spacecraft continuously for over 11 years, during which the five TDRS's placed in orbit have demonstrated their redundancies and robustness by surviving 26 component failures. Nevertheless, additional environmental testing prior to launch could prevent the occurrence of some types of failures, and could help to maintain communication services. Specific testing challenges involve traveling wave tube assemblies (TWTA's) whose lives may decrease with on-off cycling, and heaters that are subject to thermal cycles. The development of test conditions and procedures should account for known thermal variations. Testing may also have the potential to prevent failures in which components such as diplexers have had their lives dramatically shortened because of particle migration in a weightless environment. Reliability modeling could be used to select additional components that could benefit from special testing, but experience shows that this approach has serious limitations. Through knowledge of on-orbit experience, and with advances in testing, communication satellite programs might avoid the occurrence of some types of failures, and extend future spacecraft longevity beyond the current TDRS design life of ten years. However, determining which components to test, and how must testing to do, remain problematical.
Drug therapy in the prevention of failure of the Fontan circulation: a systematic review.
Oldenburger, Nathalie J; Mank, Arenda; Etnel, Jonathan; Takkenberg, Johanna J M; Helbing, Willem A
2016-06-01
The Fontan circulation is the optimal treatment for patients with univentricular hearts. These patients are at high risk of circulatory failure. There is no consensus on the optimal drug treatment for the prevention of failure of the Fontan circulation. The aim of this systematic review was to provide an overview of evidence for drug therapy used in the prevention of Fontan circulatory failure. We searched the Embase database for articles that reported drug therapy in Fontan patients. Studies published between 1997 and 2014 were included if efficacy or safety of medication was assessed, drug therapy aimed to prevent or treat failure of the Fontan circulation, and if the full text was available. Case reports were excluded. A total of nine studies were included with a total of 267 Fontan patients; four studies evaluated the medication sildenafil, one iloprost, three bosentan, and one enalapril. Among all, two sildenafil studies reported improvement in exercise capacity, one in exercise haemodynamics, and one in ventricular performance. In the largest study of bosentan, an increase in exercise capacity was found. Enalapril did not result in improvements. The studies analysed in this review suggest that bosentan, sildenafil, and iloprost may improve exercise capacity at the short term. Given the limitations of the studies, more, larger, placebo-controlled studies with longer follow-up periods are needed to better understand which drug therapies are effective in the prevention of failure of the Fontan circulation.
Blowout Prevention System Events and Equipment Component Failures : 2016 SafeOCS Annual Report
DOT National Transportation Integrated Search
2017-09-22
The SafeOCS 2016 Annual Report, produced by the Bureau of Transportation Statistics (BTS), summarizes blowout prevention (BOP) equipment failures on marine drilling rigs in the Outer Continental Shelf. It includes an analysis of equipment component f...
Could anterior papillary muscle partial necrosis explain early mitral valve repair failure?
Pozzi, Matteo; Generali, Tommaso; Henaine, Roland; Mitchell, Julia; Lemaire, Anais; Chiari, Pascal; Fran, Jean; Obadia, Jean François
2014-09-01
Standardized techniques of mitral valve repair (MVR) have recently witnessed the introduction of a 'respect rather than resect' concept, the strategy of which involves the use of artificial chordae. MVR displays several advantages over mitral valve replacement in degenerative mitral regurgitation (MR), but the risk of reoperation for MVR failure must be taken into account. Different mechanisms could be advocated as the leading cause of MVR failure; procedure-related mechanisms are usually involved in early MVR failure, while valve-related mechanisms are common in late failure. Here, the case is reported of an early failure of MVR using artificial chordae that could be explained by an unusual procedure-related mechanism, namely anterior papillary muscle necrosis. MVR failure is a well-known complication after surgical repair of degenerative MR, but anterior papillary muscle partial necrosis might also be considered a possible mechanism of procedure-related MVR failure, especially when considering the increasing use of artificial chordae. Owing to the encouraging results obtained, mitral valve re-repair might be considered a viable solution, but must be selected after only a meticulous evaluation of the underlying mechanism of MVR failure.
Chapter 10.3: Reliability and Durability of PV Modules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurtz, Sarah
2017-01-07
Each year the world invests tens of billions of dollars or euros in PV systems with the expectation that these systems will last approximately 25 years. Although the disciplines of reliability, quality, and service life prediction have been well established for numerous products, a full understanding of these is currently challenging for PV modules because the desired service lifetimes are decades, preventing direct verification of lifetime predictions. A number of excellent reviews can be found in the literature summarizing the types of failures that are commonly observed for PV modules. This chapter discusses key failure/degradation mechanisms selected to highlight howmore » the kinetics of failure rates can and cannot be confidently predicted. For EVA-encapsulated modules, corrosion is observed to follow delamination, which then allows water droplets to directly contact the metallization. Extended test protocols such as Qualification Plus were created to address the known problems while standards groups update standard tests through the consensus process.« less
Li, Y Y; McTiernan, C F; Feldman, A M
2000-05-01
Myocardial fibrosis due to maladaptive extracellular matrix remodeling contributes to dysfunction of the failing heart. Further elucidation of the mechanism by which myocardial fibrosis and dilatation can be prevented or even reversed remains of great interest as a potential means to limit myocardial remodeling and dysfunction. Matrix metalloproteinases (MMPs) are the driving force behind extracellular matrix degradation during remodeling and are increased in the failing human heart. MMPs are regulated by a variety of growth factors, cytokines, and matrix fragments such as matrikines. In the present report, we discuss the regulation of MMPs, the role of MMPs in the development of cardiac fibrosis, and the modulation of MMP activity using gene transfer and knockout technologies. We also present recent findings from our laboratory on the regulation of the extracellular MMP inducer (EMMPRIN), MMPs, and transforming growth factor-beta(1) in the failing human heart before and after left ventricular assist device support, as well as the possibility of preventing ventricular fibrosis using different anti-MMP strategies. Several studies suggest that such modulation of MMP activity can alter ventricular remodeling, myocardial dysfunction, and the progression of heart failure. It is therefore suggested that the interplay of MMPs and their regulators is important in the development of the heart failure phenotype, and myocardial fibrosis in heart failure may be modified by modulating MMP activity.
Constitutive behavior and progressive mechanical failure of electrodes in lithium-ion batteries
NASA Astrophysics Data System (ADS)
Zhang, Chao; Xu, Jun; Cao, Lei; Wu, Zenan; Santhanagopalan, Shriram
2017-07-01
The electrodes of lithium-ion batteries (LIB) are known to be brittle and to fail earlier than the separators during an external crush event. Thus, the understanding of mechanical failure mechanism for LIB electrodes (anode and cathode) is critical for the safety design of LIB cells. In this paper, we present experimental and numerical studies on the constitutive behavior and progression of failure in LIB electrodes. Mechanical tests were designed and conducted to evaluate the constitutive properties of porous electrodes. Constitutive models were developed to describe the stress-strain response of electrodes under uniaxial tensile and compressive loads. The failure criterion and a damage model were introduced to model their unique tensile and compressive failure behavior. The failure mechanism of LIB electrodes was studied using the blunt rod test on dry electrodes, and numerical models were built to simulate progressive failure. The different failure processes were examined and analyzed in detail numerically, and correlated with experimentally observed failure phenomena. The test results and models improve our understanding of failure behavior in LIB electrodes, and provide constructive insights on future development of physics-based safety design tools for battery structures under mechanical abuse.
Constitutive behavior and progressive mechanical failure of electrodes in lithium-ion batteries
Zhang, Chao; Xu, Jun; Cao, Lei; ...
2017-05-05
The electrodes of lithium-ion batteries (LIB) are known to be brittle and to fail earlier than the separators during an external crush event. Thus, the understanding of mechanical failure mechanism for LIB electrodes (anode and cathode) is critical for the safety design of LIB cells. In this paper, we present experimental and numerical studies on the constitutive behavior and progression of failure in LIB electrodes. Mechanical tests were designed and conducted to evaluate the constitutive properties of porous electrodes. Constitutive models were developed to describe the stress-strain response of electrodes under uniaxial tensile and compressive loads. The failure criterion andmore » a damage model were introduced to model their unique tensile and compressive failure behavior. The failure mechanism of LIB electrodes was studied using the blunt rod test on dry electrodes, and numerical models were built to simulate progressive failure. The different failure processes were examined and analyzed in detail numerically, and correlated with experimentally observed failure phenomena. Finally, the test results and models improve our understanding of failure behavior in LIB electrodes, and provide constructive insights on future development of physics-based safety design tools for battery structures under mechanical abuse.« less
Effects of methylphenidate on the persistence of ADHD boys following failure experiences.
Milich, R; Carlson, C L; Pelham, W E; Licht, B G
1991-10-01
We examined the effects of methylphenidate on the task persistence of 21 boys with attention-deficit hyperactivity disorder (ADHD), after they had been exposed to both solvable and insolvable problems. The boys attempted to solve 10 different find-a-word puzzles on each of 4 days, involving the crossing of medication (placebo vs. 0.3 mg/kg) and prior task difficulty (solvable vs. insolvable). The results revealed that medication prevented the decrement in performance following the insolvable problems that was evident with the placebo days. In addition, on medication compared with placebo, the boys were more likely to make external attributions for failure and internal attributions for success. The results are discussed in terms of the impact of medication on ADHD boys' performance as mediated by cognitive-motivational state mechanisms.
Collapse Mechanism Analysis in the Design of Superstructure Vehicle
NASA Astrophysics Data System (ADS)
Mohd Nor, M. K.
2016-11-01
The EU directive 2001/85/EC is an official European text which describes the specifications for “single deck class II and III vehicles” required to be approved by the regulation UN/ECE no.66 (R66). To prevent the catastrophic consequences by occupant during an accident, the Malaysian government has reinforced the same regulation upon superstructure construction. This paper discusses collapse mechanism analysis of a superstructure vehicle using a Crash D nonlinear analysis computer program based on this regulation. The analysis starts by hand calculation to define the required energy absorption by the chosen structure. Simple calculations were then performed to define the weakest collapse mechanism after undesirable collapse modes are eliminated. There are few factors highlighted in this work to pass the regulation. Using the selected cross section, Crash D simulation showed a good result. Generally, the deformation is linearly correlates to the energy absorption for the structure with low stiffness. Failure of critical members such as vertical lower side wall must be avoided to sustain safety of the passenger compartment and prevent from severe and fatal injuries to the trapped occupant.
Nonlinear analysis of collapse mechanism in superstructure vehicle
NASA Astrophysics Data System (ADS)
Nor, M. K. Mohd; Ho, C. S.; Ma'at, N.
2017-04-01
The EU directive 2001/85/EC is an official European text which describes the specifications for "single deck class II and III vehicles" required to be approved by the regulation UN/ECE no.66 (R66). To prevent the catastrophic consequences by occupant during an accident, the Malaysian government has reinforced the same regulation upon superstructure construction. This paper discusses collapse mechanism analysis of a superstructure vehicle using a Crash D nonlinear analysis computer program based on this regulation. The analysis starts by hand calculation to define the required energy absorption by the chosen structure. Simple calculations were then performed to define the weakest collapse mechanism after undesirable collapse modes are eliminated. There are few factors highlighted in this work to pass the regulation. Using the selected cross section, Crash D simulation showed a good result. Generally, the deformation is linearly correlates to the energy absorption for the structure with low stiffness. Failure of critical members such as vertical lower side wall must be avoided to sustain safety of the passenger compartment and prevent from severe and fatal injuries to the trapped occupant.
Al-Mohaissen, Maha A; Chan, Kwan Leung
2012-03-01
Endocardial lead-induced tricuspid regurgitation has not been well recognized, either clinically or echocardiographically, and yet it is likely a preventable iatrogenic disease. In severe cases, it can lead to right ventricular failure and require tricuspid valve surgery. This complication will become increasingly important, because the numbers of permanent pacemakers and implantable cardioverter-defibrillators are expected to increase because of the aging population and the expanding capabilities of these devices. Published studies are largely retrospective, and serial studies to assess the time course of the development of tricuspid regurgitation are lacking. The mechanisms and severity of tricuspid regurgitation may not be well evaluated by two-dimensional echocardiography. Real-time three-dimensional echocardiography appears to be a promising technique to evaluate the mechanism of tricuspid regurgitation and may allow the early detection of patients who will develop severe lead-induced tricuspid regurgitation. A better understanding of the mechanism of lead-induced tricuspid regurgitation will be essential to the development of preventive strategies, which can then be tested in future clinical trials. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Marshall Brinkley, D; Ali, Omair M; Zalawadiya, Sandip K; Wang, Thomas J
2017-10-01
Vitamin D is principally known for its role in calcium homeostasis, but preclinical studies implicate multiple pathways through which vitamin D may affect cardiovascular function and influence risk for heart failure. Many adults with cardiovascular disease have low vitamin D status, making it a potential therapeutic target. We review the rationale and potential role of vitamin D supplementation in the prevention and treatment of chronic heart failure. Substantial observational evidence has associated low vitamin D status with the risk of heart failure, ventricular remodeling, and clinical outcomes in heart failure, including mortality. However, trials assessing the influence of vitamin D supplementation on surrogate markers and clinical outcomes in heart failure have generally been small and inconclusive. There are insufficient data to recommend routine assessment or supplementation of vitamin D for the prevention or treatment of chronic heart failure. Prospective trials powered for clinical outcomes are warranted.
Tribological Properties of Structural Ceramics
NASA Technical Reports Server (NTRS)
Buckley, Donald H.; Miyoshi, Kazuhisa
1987-01-01
Paper discusses tribological properties of structural ceramics. Function of tribological research is to bring about reduction in adhesion, friction, and wear of mechanical components; to prevent failures; and to provide long, reliable component life, through judicious selection of materials, operating parameters, and lubricants. Paper reviews adhesion, friction, wear, and lubrication of ceramics; anisotropic friction and wear behavior; and effects of surface films and interactions between ceramics and metals. Analogies with metals are made. Both oxide and nonoxide ceramics, including ceramics used as high temperature lubricants, are dicussed.
Yoshida, Tadashi; Semprun-Prieto, Laura; Sukhanov, Sergiy
2010-01-01
Congestive heart failure is associated with activation of the renin-angiotensin system and skeletal muscle wasting. Angiotensin II (ANG II) has been shown to increase muscle proteolysis and decrease circulating and skeletal muscle IGF-1. We have shown previously that skeletal muscle-specific overexpression of IGF-1 prevents proteolysis and apoptosis induced by ANG II. These findings indicated that downregulation of IGF-1 signaling in skeletal muscle played an important role in the wasting effect of ANG II. However, the signaling pathways and mechanisms whereby IGF-1 prevents ANG II-induced skeletal muscle atrophy are unknown. Here we show ANG II-induced transcriptional regulation of two ubiquitin ligases atrogin-1 and muscle ring finger-1 (MuRF-1) that precedes the reduction of skeletal muscle IGF-1 expression, suggesting that activation of atrogin-1 and MuRF-1 is an initial mechanism leading to skeletal muscle atrophy in response to ANG II. IGF-1 overexpression in skeletal muscle prevented ANG II-induced skeletal muscle wasting and the expression of atrogin-1, but not MuRF-1. Dominant-negative Akt and constitutively active Foxo-1 blocked the ability of IGF-1 to prevent ANG II-mediated upregulation of atrogin-1 and skeletal muscle wasting. Our findings demonstrate that the ability of IGF-1 to prevent ANG II-induced skeletal muscle wasting is mediated via an Akt- and Foxo-1-dependent signaling pathway that results in inhibition of atrogin-1 but not MuRF-1 expression. These data suggest strongly that atrogin-1 plays a critical role in mechanisms of ANG II-induced wasting in vivo. PMID:20228261
Global left atrial failure in heart failure.
Triposkiadis, Filippos; Pieske, Burkert; Butler, Javed; Parissis, John; Giamouzis, Gregory; Skoularigis, John; Brutsaert, Dirk; Boudoulas, Harisios
2016-11-01
The left atrium plays an important role in the maintenance of cardiovascular and neurohumoral homeostasis in heart failure. However, with progressive left ventricular dysfunction, left atrial (LA) dilation and mechanical failure develop, which frequently culminate in atrial fibrillation. Moreover, LA mechanical failure is accompanied by LA endocrine failure [deficient atrial natriuretic peptide (ANP) processing-synthesis/development of ANP resistance) and LA regulatory failure (dominance of sympathetic nervous system excitatory mechanisms, excessive vasopressin release) contributing to neurohumoral overactivity, vasoconstriction, and volume overload (global LA failure). The purpose of the present review is to describe the characteristics and emphasize the clinical significance of global LA failure in patients with heart failure. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.
A robot end effector exchange mechanism for space applications
NASA Technical Reports Server (NTRS)
Gorin, Barney F.
1990-01-01
Efficient robot operation requires the use of specialized end effectors or tools for tasks. In spacecraft applications, the microgravity environment precludes the use of gravitational forces to retain the tools in holding fixture. As a result of this, a retention mechanism which forms a part of the tool storage container is required. A unique approach to this problem has resulted in the development of an end effector exchange mechanism that meets the requirements for spaceflight applications while avoiding the complexity usually involved. This mechanism uses multiple latching cams both on the manipulator and in the tool storage container, combined with a system of catch rings to provide retention in both locations and the required failure tolerance. Because of the cam configuration the mechanism operates passively, requiring no electrical commands except those needed to move the manipulator into position. Similarly, it inherently provides interlocks to prevent the release of one cam before its opposite number is engaged.
Stefaniak, Katarzyna; Wróżyńska, Magdalena
2018-02-01
Protection of common natural goods is one of the greatest challenges man faces every day. Extracting and processing natural resources such as mineral deposits contributes to the transformation of the natural environment. The number of activities designed to keep balance are undertaken in accordance with the concept of integrated order. One of them is the use of comprehensive systems of tailings storage facility monitoring. Despite the monitoring, system failures still occur. The quantitative aspect of the failures illustrates both the scale of the problem and the quantitative aspect of the consequences of tailings storage facility failures. The paper presents vast possibilities provided by the global monitoring in the effective prevention of these failures. Particular attention is drawn to the potential of using multidirectional monitoring, including technical and environmental monitoring by the example of one of the world's biggest hydrotechnical constructions-Żelazny Most Tailings Storage Facility (TSF), Poland. Analysis of monitoring data allows to take preventive action against construction failures of facility dams, which can have devastating effects on human life and the natural environment.
16 CFR 1702.5 - Failure to supply adverse information.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Failure to supply adverse information. 1702.5 Section 1702.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION POISON PREVENTION PACKAGING ACT OF 1970 REGULATIONS PETITIONS FOR EXEMPTIONS FROM POISON PREVENTION PACKAGING ACT REQUIREMENTS...
16 CFR 1702.5 - Failure to supply adverse information.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Failure to supply adverse information. 1702.5 Section 1702.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION POISON PREVENTION PACKAGING ACT OF 1970 REGULATIONS PETITIONS FOR EXEMPTIONS FROM POISON PREVENTION PACKAGING ACT REQUIREMENTS...
16 CFR 1702.5 - Failure to supply adverse information.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Failure to supply adverse information. 1702.5 Section 1702.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION POISON PREVENTION PACKAGING ACT OF 1970 REGULATIONS PETITIONS FOR EXEMPTIONS FROM POISON PREVENTION PACKAGING ACT REQUIREMENTS...
16 CFR 1702.5 - Failure to supply adverse information.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Failure to supply adverse information. 1702.5 Section 1702.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION POISON PREVENTION PACKAGING ACT OF 1970 REGULATIONS PETITIONS FOR EXEMPTIONS FROM POISON PREVENTION PACKAGING ACT REQUIREMENTS...
Rocha, Lilian Wünsch; Bonet, Ivan José Magayewski; Tambeli, Claudia Herrera; de-Faria, Felipe Meira; Parada, Carlos Amilcar
2018-07-05
Steroidal and non-steroidal anti-inflammatory drugs (NSAIDs) are widely used to control inflammatory pain, but there is a risk of gastrointestinal bleeding and increased heart failure risk. The search for new drugs remains ongoing, and natural products are a source for potential new compounds. Mangiferin, a natural xanthone C-glucoside, has demonstrated biological activity, including anti-inflammatory and analgesic properties, but it's mechanisms are poorly understood. In this study, we investigated the mechanisms underlying the anti-inflammatory and analgesic effects of local administration of mangiferin. We employed an electronic von Frey apparatus to evaluate mechanical hyperalgesia induced by carrageenan in rats. Mangiferin (150-1200 µg/paw), administered locally into the hindpaw, prevented hyperalgesia in a dose-dependent - 150 µg (- 9%), 300 µg (- 27%, P < 0.01), 600 µg (- 77%, P < 0.001) and 1000 µg (- 93%, P < 0.001) - and local manner. Mangiferin showed decreased levels of TNF-α (P < 0.001) and CINC-1 (P < 0.001), but not IL-1β; it also prevented neutrophil migration (P < 0.01), but not the increased COX-2 expression in peripheral tissue challenged with carrageenan. To further explore the mechanisms of mangiferin actions, rats were injected with modulators of inflammation and nociception; mangiferin prevented hyperalgesia induced by IL-1β (P < 0.01), CINC-1 (P < 0.01), epinephrine (P < 0.01), 8-Br-cAMP (P < 0.01) or capsaicin (P < 0.01), but not that induced by PGE 2 or α,β-MeATP. Our study shows that mangiferin has anti-inflammatory and analgesic properties when locally administrated. The control of the inflammatory response and mechanical hyperalgesia by mangiferin depends on the inhibition of TNF-α production/release and the CINC1/epinephrine/PKA pathway, supporting its marked inhibition of inflammatory mechanical hyperalgesia. Copyright © 2018 Elsevier B.V. All rights reserved.
Health Care: A Report on the Industry 2004
2004-06-01
in fact are soaring out of proportion to the quality of care provided to the population as a whole. Market failures prevent the health care industry... failures prevent the health care industry from reaching its best potential efficiency in terms of resource allocation; the disconnect between buyers and...and-a-half points higher than the federal standard), 1,400 service members were discharged for failure to meet the metric in 2002, joining more than
Software Health Management: A Short Review of Challenges and Existing Techniques
NASA Technical Reports Server (NTRS)
Pipatsrisawat, Knot; Darwiche, Adnan; Mengshoel, Ole J.; Schumann, Johann
2009-01-01
Modern spacecraft (as well as most other complex mechanisms like aircraft, automobiles, and chemical plants) rely more and more on software, to a point where software failures have caused severe accidents and loss of missions. Software failures during a manned mission can cause loss of life, so there are severe requirements to make the software as safe and reliable as possible. Typically, verification and validation (V&V) has the task of making sure that all software errors are found before the software is deployed and that it always conforms to the requirements. Experience, however, shows that this gold standard of error-free software cannot be reached in practice. Even if the software alone is free of glitches, its interoperation with the hardware (e.g., with sensors or actuators) can cause problems. Unexpected operational conditions or changes in the environment may ultimately cause a software system to fail. Is there a way to surmount this problem? In most modern aircraft and many automobiles, hardware such as central electrical, mechanical, and hydraulic components are monitored by IVHM (Integrated Vehicle Health Management) systems. These systems can recognize, isolate, and identify faults and failures, both those that already occurred as well as imminent ones. With the help of diagnostics and prognostics, appropriate mitigation strategies can be selected (replacement or repair, switch to redundant systems, etc.). In this short paper, we discuss some challenges and promising techniques for software health management (SWHM). In particular, we identify unique challenges for preventing software failure in systems which involve both software and hardware components. We then present our classifications of techniques related to SWHM. These classifications are performed based on dimensions of interest to both developers and users of the techniques, and hopefully provide a map for dealing with software faults and failures.
[Perioperative acute kidney injury and failure].
Chhor, Vibol; Journois, Didier
2014-04-01
Perioperative period is very likely to lead to acute renal failure because of anesthesia (general or perimedullary) and/or surgery which can cause acute kidney injury. Characterization of acute renal failure is based on serum creatinine level which is imprecise during and following surgery. Studies are based on various definitions of acute renal failure with different thresholds which skewed their comparisons. The RIFLE classification (risk, injury, failure, loss, end stage kidney disease) allows clinicians to distinguish in a similar manner between different stages of acute kidney injury rather than using a unique definition of acute renal failure. Acute renal failure during the perioperative period can mainly be explained by iatrogenic, hemodynamic or surgical causes and can result in an increased morbi-mortality. Prevention of this complication requires hemodynamic optimization (venous return, cardiac output, vascular resistance), discontinuation of nephrotoxic drugs but also knowledge of the different steps of the surgery to avoid further degradation of renal perfusion. Diuretics do not prevent acute renal failure and may even push it forward especially during the perioperative period when venous retourn is already reduced. Edema or weight gain following surgery are not correlated with the vascular compartment volume, much less with renal perfusion. Treatment of perioperative acute renal failure is similar to other acute renal failure. Renal replacement therapy must be mastered to prevent any additional risk of hemodynamic instability or hydro-electrolytic imbalance. Copyright © 2014 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.
Extended Testability Analysis Tool
NASA Technical Reports Server (NTRS)
Melcher, Kevin; Maul, William A.; Fulton, Christopher
2012-01-01
The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.
Cicero, Arrigo F G; Colletti, Alessandro
2017-01-01
Heart failure (HF) is a complex clinical syndrome that can result from any structural or functional cardiac disorder that impairs the ability of the ventricle to fill or eject blood. It represents a major public health issue, with a prevalence of over 23 million worldwide. The lifetime risk of developing HF is one in five and the most important risk factors identified are ischemic heart disease, hypertension, smoking, obesity and diabetes. Preventive approaches are based on improvements of lifestyle, associated with pharmacological therapy. Several nutraceuticals have shown interesting clinical results in prevention of HF as well as in the treatment of the early stages of the disease, alone or in association with pharmacological therapy. The aim of this review is to resume the available clinical evidence on phytochemicals effect on HF prevention and/or treatment. A systematic search strategy was developed to identify trials in PubMed (January 1980 to April 2016). The terms 'nutraceuticals', 'dietary supplements', 'herbal drug' and 'heart failure' were incorporated into an electronic search strategy. Clinical trials reported that the intake of some nutraceuticals (hawthorn, coenzyme Q10, L-carnitine, Dribose, Carnosine, Vitamin D, Some probiotics, Omega-3 PUFAs, Beet nitrates) is associated with improvements in functional parameters such as ejection fraction, stroke volume and cardiac output in HF patients, with minimal side effects. These findings were sometimes reinforced by subsequent meta-analyses, which further concluded that benefits tended to be greater in earlier stage HF. The main mechanisms involved are antioxidant, antinflammatory, anti-ischemic and antiaggregant effects. Evidence suggests that the supplementation with nutraceuticals may be a useful option for effective management of HF, with the advantage of excellent clinical tolerance. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Chang, Suchi; Shi, Jindong; Fu, Cuiping; Wu, Xu; Li, Shanqun
2016-01-01
Background COPD is the third leading cause of death worldwide. Acute exacerbations of COPD may cause respiratory failure, requiring intensive care unit admission and mechanical ventilation. Intensive care unit patients with acute exacerbations of COPD requiring mechanical ventilation have higher mortality rates than other hospitalized patients. Although mechanical ventilation is the most effective intervention for these conditions, invasive ventilation techniques have yielded variable effects. Objective We evaluated pressure-regulated volume control (PRVC) ventilation treatment efficacy and preventive effects on pulmonary barotrauma in elderly COPD patients with respiratory failure. Patients and methods Thirty-nine intubated patients were divided into experimental and control groups and treated with the PRVC and synchronized intermittent mandatory ventilation – volume control methods, respectively. Vital signs, respiratory mechanics, and arterial blood gas analyses were monitored for 2–4 hours and 48 hours. Results Both groups showed rapidly improved pH, partial pressure of oxygen (PaO2), and PaO2 per fraction of inspired O2 levels and lower partial pressure of carbon dioxide (PaCO2) levels. The pH and PaCO2 levels at 2–4 hours were lower and higher, respectively, in the test group than those in the control group (P<0.05 for both); after 48 hours, blood gas analyses showed no statistical difference in any marker (P>0.05). Vital signs during 2–4 hours and 48 hours of treatment showed no statistical difference in either group (P>0.05). The level of peak inspiratory pressure in the experimental group after mechanical ventilation for 2–4 hours and 48 hours was significantly lower than that in the control group (P<0.05), while other variables were not significantly different between groups (P>0.05). Conclusion Among elderly COPD patients with respiratory failure, application of PRVC resulted in rapid improvement in arterial blood gas analyses while maintaining a low peak inspiratory pressure. PRVC can reduce pulmonary barotrauma risk, making it a safer protective ventilation mode than synchronized intermittent mandatory ventilation – volume control. PMID:27274223
Chang, Suchi; Shi, Jindong; Fu, Cuiping; Wu, Xu; Li, Shanqun
2016-01-01
COPD is the third leading cause of death worldwide. Acute exacerbations of COPD may cause respiratory failure, requiring intensive care unit admission and mechanical ventilation. Intensive care unit patients with acute exacerbations of COPD requiring mechanical ventilation have higher mortality rates than other hospitalized patients. Although mechanical ventilation is the most effective intervention for these conditions, invasive ventilation techniques have yielded variable effects. We evaluated pressure-regulated volume control (PRVC) ventilation treatment efficacy and preventive effects on pulmonary barotrauma in elderly COPD patients with respiratory failure. Thirty-nine intubated patients were divided into experimental and control groups and treated with the PRVC and synchronized intermittent mandatory ventilation - volume control methods, respectively. Vital signs, respiratory mechanics, and arterial blood gas analyses were monitored for 2-4 hours and 48 hours. Both groups showed rapidly improved pH, partial pressure of oxygen (PaO2), and PaO2 per fraction of inspired O2 levels and lower partial pressure of carbon dioxide (PaCO2) levels. The pH and PaCO2 levels at 2-4 hours were lower and higher, respectively, in the test group than those in the control group (P<0.05 for both); after 48 hours, blood gas analyses showed no statistical difference in any marker (P>0.05). Vital signs during 2-4 hours and 48 hours of treatment showed no statistical difference in either group (P>0.05). The level of peak inspiratory pressure in the experimental group after mechanical ventilation for 2-4 hours and 48 hours was significantly lower than that in the control group (P<0.05), while other variables were not significantly different between groups (P>0.05). Among elderly COPD patients with respiratory failure, application of PRVC resulted in rapid improvement in arterial blood gas analyses while maintaining a low peak inspiratory pressure. PRVC can reduce pulmonary barotrauma risk, making it a safer protective ventilation mode than synchronized intermittent mandatory ventilation - volume control.
Nanocrystalline diamond coatings for mechanical seals applications.
Santos, J A; Neto, V F; Ruch, D; Grácio, J
2012-08-01
A mechanical seal is a type of seal used in rotating equipment, such as pumps and compressors. It consists of a mechanism that assists the connection of the rotating shaft to the housings of the equipments, preventing leakage or avoiding contamination. A common cause of failure of these devices is end face wear out, thus the use of a hard, smooth and wear resistant coating such as nanocrystalline diamond would be of great importance to improve their working performance and increase their lifetime. In this paper, different diamond coatings were deposited by the HFCVD process, using different deposition conditions. Additionally, the as-grown films were characterized for, quality, morphology and microstructure using scanning electron microscopy (SEM) and Raman spectroscopy. The topography and the roughness of the films were characterized by atomic force microscopy (AFM).
16 CFR § 1702.5 - Failure to supply adverse information.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Failure to supply adverse information. § 1702.5 Section § 1702.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION POISON PREVENTION PACKAGING ACT OF 1970 REGULATIONS PETITIONS FOR EXEMPTIONS FROM POISON PREVENTION PACKAGING ACT REQUIREMENTS...
Code of Federal Regulations, 2014 CFR
2014-10-01
... the main reservoir air pressure. The operating valve handle for such connection shall be conveniently... automatically prevent loss of pressure in event of failure of the main reservoir air pressure. (c) Power reverse... automatically prevent the loss of pressure in the event of a failure of main air pressure and have storage...
Code of Federal Regulations, 2011 CFR
2011-10-01
... the main reservoir air pressure. The operating valve handle for such connection shall be conveniently... automatically prevent loss of pressure in event of failure of the main reservoir air pressure. (c) Power reverse... automatically prevent the loss of pressure in the event of a failure of main air pressure and have storage...
Code of Federal Regulations, 2012 CFR
2012-10-01
... the main reservoir air pressure. The operating valve handle for such connection shall be conveniently... automatically prevent loss of pressure in event of failure of the main reservoir air pressure. (c) Power reverse... automatically prevent the loss of pressure in the event of a failure of main air pressure and have storage...
Code of Federal Regulations, 2013 CFR
2013-10-01
... the main reservoir air pressure. The operating valve handle for such connection shall be conveniently... automatically prevent loss of pressure in event of failure of the main reservoir air pressure. (c) Power reverse... automatically prevent the loss of pressure in the event of a failure of main air pressure and have storage...
[Elective caesarean: impact of evolution neonatal respiration].
Jonguitud Aguilar, Adriana
2011-04-01
The number of Caesarean births has increased worldwide. Respiratory distress syndrome is associated with caesarean delivery, especially in the absence of labor. During the latter stages of pregnancy physiologic changes occur that are accelerated with the onset of labor, which is accompanied by changes in hormones and mediators in the mother and fetus. An acceleration in the evacuation of lung liquid is held in this period, largely dependent sodium channels sensitive to amiloride than are found in the alveolar epithelium. The failure of these mechanisms can lead to newborn severe respiratory difficulty and require intensive care, mechanical ventilation and surfactant. We need to develop preventive and therapeutic strategies to improve outcomes in this vulnerable population.
NASA Technical Reports Server (NTRS)
Quade, Derek J.; Jana, Sadhan C.; Morscher, Gregory N.; Kannan, Manigandan; McCorkle, Linda S.
2017-01-01
Nickel-titanium (NiTi) shape memory alloy (SMA) sections were embedded within carbon fiber reinforced polymer matrix composite (CFRPPMC) laminates and their tensile properties were evaluated with simultaneous monitoring of modal acoustic emissions. The test specimens were fabricated in three different layup configurations and two different thin film adhesives were applied to bond the SMA with the PMC. A trio of acoustic sensors were attached to the specimens during tensile testing to monitor the modal acoustic emission (AE) as the materials experienced mechanical failure. The values of ultimate tensile strengths, strains, and moduli were obtained. Cumulative AE energy of events and specimen failure location were determined. In conjunction, optical and scanning electron microscopy techniques were used to examine the break areas of the specimens. The analysis of AE data revealed failure locations within the specimens which were validated from the microscopic images. The placement of 90 deg plies in the outer ply gave the strongest acoustic signals during break as well as the cleanest break of the samples tested. Overlapping 0 deg ply layers surrounding the SMA was found to be the best scenario to prevent failure of the specimen itself.
Dystrophic heart failure blocked by membrane sealant poloxamer
NASA Astrophysics Data System (ADS)
Yasuda, Soichiro; Townsend, Dewayne; Michele, Daniel E.; Favre, Elizabeth G.; Day, Sharlene M.; Metzger, Joseph M.
2005-08-01
Dystrophin deficiency causes Duchenne muscular dystrophy (DMD) in humans, an inherited and progressive disease of striated muscle deterioration that frequently involves pronounced cardiomyopathy. Heart failure is the second leading cause of fatalities in DMD. Progress towards defining the molecular basis of disease in DMD has mostly come from studies on skeletal muscle, with comparatively little attention directed to cardiac muscle. The pathophysiological mechanisms involved in cardiac myocytes may differ significantly from skeletal myofibres; this is underscored by the presence of significant cardiac disease in patients with truncated or reduced levels of dystrophin but without skeletal muscle disease. Here we show that intact, isolated dystrophin-deficient cardiac myocytes have reduced compliance and increased susceptibility to stretch-mediated calcium overload, leading to cell contracture and death, and that application of the membrane sealant poloxamer 188 corrects these defects in vitro. In vivo administration of poloxamer 188 to dystrophic mice instantly improved ventricular geometry and blocked the development of acute cardiac failure during a dobutamine-mediated stress protocol. Once issues relating to optimal dosing and long-term effects of poloxamer 188 in humans have been resolved, chemical-based membrane sealants could represent a new therapeutic approach for preventing or reversing the progression of cardiomyopathy and heart failure in muscular dystrophy.
Von Ruden, Serena A S; Murray, Margaret A; Grice, Jennifer L; Proebstle, Amy K; Kopacek, Karen J
2012-04-01
Advances in mechanical circulatory support, such as the use of ventricular assist devices (VADs), have become a means for prolonging survival in end-stage heart failure (HF). VADs decrease the symptoms of HF and improve quality of life by replacing some of the work of a failing heart. They unload the ventricle to provide improved cardiac output and end-organ perfusion, resulting in improvement in cardiorenal syndromes and New York Heart Association functional class rating. VADs are currently used asa bridge to heart transplantation, a bridge to recovery of cardiac function, or as destination therapy. Complications of VAD include bleeding, infections, arrhythmias, multiple organ failure, right ventricular failure, and neurological dysfunction. Patients with VAD have unique pharmacotherapeutic requirements in terms of anticoagulation, appropriate antibiotic selection, and continuation of HF medications. Pharmacists in acute care and community settings are well prepared to care for the patient with VAD. These patients require thorough counseling and follow-up with regard to prevention and treatment of infections, appropriate levels of anticoagulation, and maintenance of fluid balance. A basic understanding of this unique therapy can assist pharmacists in attending to the needs of patients with VAD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spencer, B. W.; Williamson, R. L.; Stafford, D. S.
One of the important roles of cladding in light water reactor fuel rods is to prevent the release of fission products. To that end, it is essential that the cladding maintain its integrity under a variety of thermal and mechanical loading conditions. Local geometric irregularities in fuel pellets caused by manufacturing defects known as missing pellet surfaces (MPS) can in some circumstances lead to elevated cladding stresses that are sufficiently high to cause cladding failure. Accurate modeling of these defects can help prevent these types of failures. The BISON nuclear fuel performance code developed at Idaho National Laboratory can bemore » used to simulate the global thermo-mechanical fuel rod behavior, as well as the local response of regions of interest, in either 2D or 3D. In either case, a full set of models to represent the thermal and mechanical properties of the fuel, cladding and plenum gas is employed. A procedure for coupling 2D full-length fuel rod models to detailed 3D models of the region of the rod containing a MPS defect is detailed in this paper. The global and local model each contain appropriate physics and behavior models for nuclear fuel. This procedure is demonstrated on a simulation of a boiling water reactor (BWR) fuel rod containing a pellet with an MPS defect, subjected to a variety of transient events, including a control blade withdrawal and a ramp to high power. The importance of modeling the local defect using a 3D model is highlighted by comparing 3D and 2D representations of the defective pellet region. Finally, parametric studies demonstrate the effects of the choice of gaseous swelling model and of the depth and geometry of the MPS defect on the response of the cladding adjacent to the defect.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Chao; Xu, Jun; Cao, Lei
The electrodes of lithium-ion batteries (LIB) are known to be brittle and to fail earlier than the separators during an external crush event. Thus, the understanding of mechanical failure mechanism for LIB electrodes (anode and cathode) is critical for the safety design of LIB cells. In this paper, we present experimental and numerical studies on the constitutive behavior and progression of failure in LIB electrodes. Mechanical tests were designed and conducted to evaluate the constitutive properties of porous electrodes. Constitutive models were developed to describe the stress-strain response of electrodes under uniaxial tensile and compressive loads. The failure criterion andmore » a damage model were introduced to model their unique tensile and compressive failure behavior. The failure mechanism of LIB electrodes was studied using the blunt rod test on dry electrodes, and numerical models were built to simulate progressive failure. The different failure processes were examined and analyzed in detail numerically, and correlated with experimentally observed failure phenomena. Finally, the test results and models improve our understanding of failure behavior in LIB electrodes, and provide constructive insights on future development of physics-based safety design tools for battery structures under mechanical abuse.« less
Engelhardt, P
1979-10-01
Prevention of further detachment is the primary aim in the immediate treatment of beginning juvenile detachment of the femoral head. Screwing of the epiphysis of the head, first introduced by M. E. Mueller (1965), has proved successful. Besides providing immediate mechanical stability, this method, however, results in premature ossification of the joint of the femoral neck. Epiphysiodesis has a particularly unfavourable effect in early childhood, because it inhibits proper growth of the leg and development of the mechanism of the hip joint on account of the shortened femoral neck. Spiking of the epiphysis with Krischner screw wires guarantees safe fixation of the epiphyseal head on the one hand, and sufficient freedom of femoral neck growth on the other. Surgical treatment requires knowledge of the changed hip joint anatomy of the child. Preoperative planning via drawing to determine the length and position of the implantate on the basis of standardised x-ray films, will help to prevent operative failures.
NASA Astrophysics Data System (ADS)
Nasrum, A.; Pasaribu, U. S.; Husniah, H.
2016-02-01
This paper deals with maintenance service contract for a dump truck sold with a two-dimensional warranties. We consider a situation where an agent offers two maintenance contract options and the owner of the equipment has to select the optimal option either the OEM carried out all repairs and preventive maintenance activities (option one) or the OEM only carries out failure while the costumer undertakes preventive maintenance action in-house (option two). As the number of preventive maintenance and corrective maintenance that occurs in the area of servicing contracts is very influential in determining the value of the contract, we have to determine the optimal time between preventive maintenance that can minimize the cost of repair in the contract area. Moreover, we also study the maintenance service contract considering reduction of the intensity function after preventive maintenance from both the owner and OEM point of views. In this paper, we use a Weibull intensity function to consider a product with increasing failure intensity. We use a non-cooperative game formulation to determine the optimal price structure (i.e., the contract price and repair cost) for the OEM and the owner. A numerical example derived from the model has shown that if the owner choose option one then the owner obtain a higher profit compared with the profit resulted from option two. The result agree with earlier work which uses the accelerated failure time (AFT) for the failure modeling, while here we model the failure of the dump truck without the use of the AFT.
Honda, Nobuhiro; Hirooka, Yoshitaka; Ito, Koji; Matsukawa, Ryuichi; Shinohara, Keisuke; Kishi, Takuya; Yasukawa, Keiji; Utsumi, Hideo; Sunagawa, Kenji
2013-11-01
Enhanced central sympathetic outflow is an indicator of the prognosis of heart failure. Although the central sympatholytic drug moxonidine is an established therapeutic strategy for hypertension, its benefits for hypertensive heart failure are poorly understood. In the present study, we investigated the effects of central sympathoinhibition by intracerebral infusion of moxonidine on survival in a rat model of hypertensive heart failure and the possible mechanisms involved. As a model of hypertensive heart failure, we fed Dahl salt-sensitive rats an 8% NaCl diet from 7 weeks of age. Intracerebroventricular (ICV) infusion of moxonidine (moxonidine-ICV-treated group [Mox-ICV]) or vehicle (vehicle-ICV-treated group [Veh-ICV]) was performed at 14-20 weeks of age, during the increased heart failure phase. Survival rates were examined, and sympathetic activity, left ventricular function and remodelling, and brain oxidative stress were measured. Hypertension and left ventricular hypertrophy were established by 13 weeks of age. At around 20 weeks of age, Veh-ICV rats exhibited overt heart failure concomitant with increased urinary norepinephrine (uNE) excretion as an index of sympathetic activity, dilated left ventricle, decreased percentage fractional shortening, and myocardial fibrosis. Survival rates at 21 weeks of age (n = 28) were only 23% in Veh-ICV rats, and 76% (n = 17) in Mox-ICV rats with concomitant decreases in uNE, myocardial fibrosis, collagen type I/III ratio, brain oxidative stress, and suppressed left ventricular dysfunction. Moxonidine-induced central sympathoinhibition attenuated brain oxidative stress, prevented cardiac dysfunction and remodelling, and improved the prognosis in rats with hypertensive heart failure. Central sympathoinhibition can be effective for the treatment of hypertensive heart failure.
Dabkowski, Erinne R; O'Connell, Kelly A; Xu, Wenhong; Ribeiro, Rogerio F; Hecker, Peter A; Shekar, Kadambari Chandra; Daneault, Caroline; Des Rosiers, Christine; Stanley, William C
2013-12-01
Supplementation with the n3 polyunsaturated fatty acid docosahexaenoic acid (DHA) is beneficial in heart failure patients, however the mechanisms are unclear. DHA is incorporated into membrane phospholipids, which may prevent mitochondrial dysfunction. Thus we assessed the effects of DHA supplementation on cardiac mitochondria and the development of heart failure caused by aortic pressure overload. Pathological cardiac hypertrophy was generated in rats by thoracic aortic constriction. Animals were fed either a standard diet or were supplemented with DHA (2.3 % of energy intake). After 14 weeks, heart failure was evident by left ventricular hypertrophy and chamber enlargement compared to shams. Left ventricle fractional shortening was unaffected by DHA treatment in sham animals (44.1 ± 1.6 % vs. 43.5 ± 2.2 % for standard diet and DHA, respectively), and decreased with heart failure in both treatment groups, but to a lesser extent in DHA treated animals (34.9 ± 1.7 %) than with the standard diet (29.7 ± 1.5 %, P < 0.03). DHA supplementation increased DHA content in mitochondrial phospholipids and decreased membrane viscosity. Myocardial mitochondrial oxidative capacity was decreased by heart failure and unaffected by DHA. DHA treatment enhanced Ca(2+) uptake by subsarcolemmal mitochondria in both sham and heart failure groups. Further, DHA lessened Ca(2+)-induced mitochondria swelling, an index of permeability transition, in heart failure animals. Heart failure increased hydrogen peroxide-induced mitochondrial permeability transition compared to sham, which was partially attenuated in interfibrillar mitochondria by treatment with DHA. DHA decreased mitochondrial membrane viscosity and accelerated Ca(2+) uptake, and attenuated susceptibility to mitochondrial permeability transition and development of left ventricular dysfunction.
The Role of the Nrf2/ARE Antioxidant System in Preventing Cardiovascular Diseases
Smith, Robert E.; Tran, Kevin; Smith, Cynthia C.; McDonald, Miranda; Shejwalkar, Pushkar; Hara, Kenji
2016-01-01
It is widely believed that consuming foods and beverages that have high concentrations of antioxidants can prevent cardiovascular diseases and many types of cancer. As a result, many articles have been published that give the total antioxidant capacities of foods in vitro. However, many antioxidants behave quite differently in vivo. Some of them, such as resveratrol (in red wine) and epigallocatechin gallate or EGCG (in green tea) can activate the nuclear erythroid-2 like factor-2 (Nrf2) transcription factor. It is a master regulator of endogenous cellular defense mechanisms. Nrf2 controls the expression of many antioxidant and detoxification genes, by binding to antioxidant response elements (AREs) that are commonly found in the promoter region of antioxidant (and other) genes, and that control expression of those genes. The mechanisms by which Nrf2 relieves oxidative stress and limits cardiac injury as well as the progression to heart failure are described. Also, the ability of statins to induce Nrf2 in the heart, brain, lung, and liver is mentioned. However, there is a negative side of Nrf2. When over-activated, it can cause (not prevent) cardiovascular diseases and multi-drug resistance cancer. PMID:28933413
Ngure, Kenneth; Vusha, Sophie; Mugo, Nelly; Emmanuel-Fabula, Mira; Ngutu, Mariah; Celum, Connie; Baeten, Jared M; Heffron, Renee
2016-12-01
In spite of access to behavioral and biomedical HIV prevention strategies, HIV transmission occurs. For HIV-serodiscordant couples, prevention programs can be tailored to address individual and couples' needs to preserve their relationship while minimizing HIV risk. Programs for serodiscordant couples may benefit from learning from experiences of couples who transmit HIV. We conducted 20 individual in-depth interviews with 10 initially HIV-serodiscordant couples who transmitted HIV during prospective follow-up at a peri-urban research site in Thika, Kenya. Data were analyzed inductively to identify situations that led to prevention failure and coping mechanisms. Inconsistent condom use driven by low HIV risk perception and alcohol use often preceded seroconversion while persistent blame frequently hindered couples' communication soon after seroconversion. In this emerging era of antiretroviral-based HIV prevention, couples' counseling can capitalize on opportunities to foster a supportive environment to discuss initiation and adherence to time-limited pre-exposure prophylaxis and lifelong antiretroviral therapy, in addition to strategies to reduce alcohol use, diffuse blame, and use condoms.
Ogawa, Kiyohiro; Hirooka, Yoshitaka; Kishi, Takuya; Ide, Tomomi; Sunagawa, Kenji
2013-01-01
Left ventricular (LV) remodeling and activation of sympathetic nervous system (SNS) are cardinal features of heart failure. We previously demonstrated that enhanced central sympathetic outflow is associated with brain toll-like receptor 4 (TLR4) probably mediated by brain angiotensin II type 1 receptor in mice with myocardial infarction (MI)-induced heart failure. The purpose of the present study was to examine whether silencing brain TLR4 could prevent LV remodeling with sympathoinhibition in MI-induced heart failure. MI-induced heart failure model rats were created by ligation of left coronary artery. The expression level of TLR4 in brainstem was significantly higher in MI-induced heart failure treated with intracerebroventricular (ICV) injection of hGAPDH-SiRNA than in sham. TLR4 in brainstem was significantly lower in MI-induced heart failure treated with ICV injection of TLR4-SiRNA than in that treated with ICV injection of hGAPDH-SiRNA. Lung weight, urinary norepinephrine excretion, and LV end-diastolic pressure were significantly lower and LV dimension was significantly smaller in MI-induced heart failure treated with TLR4-SiRNA than in that treated with hGAPDH-SiRNA for 2 weeks. Partially silencing brain TLR4 by ICV injection of TLR4-SiRNA for 2 weeks could in part prevent LV remodeling with sympathoinhibition in rats with MI-induced heart failure. Brain TLR4 has a potential to be a target of the treatment for MI-induced heart failure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, Chao Chung, E-mail: ho919@pchome.com.tw; Liao, Ching-Jong
Highlights: > This study is based on a real case in a regional teaching hospital in Taiwan. > We use Failure mode and effects analysis (FMEA) as the evaluation method. > We successfully identify the risk factors of infectious waste disposal. > We propose plans for the detection of exceptional cases of infectious waste. - Abstract: In recent times, the quality of medical care has been continuously improving in medical institutions wherein patient-centred care has been emphasized. Failure mode and effects analysis (FMEA) has also been promoted as a method of basic risk management and as part of total qualitymore » management (TQM) for improving the quality of medical care and preventing mistakes. Therefore, a study was conducted using FMEA to evaluate the potential risk causes in the process of infectious medical waste disposal, devise standard procedures concerning the waste, and propose feasible plans for facilitating the detection of exceptional cases of infectious waste. The analysis revealed the following results regarding medical institutions: (a) FMEA can be used to identify the risk factors of infectious waste disposal. (b) During the infectious waste disposal process, six items were scored over 100 in the assessment of uncontrolled risks: erroneous discarding of infectious waste by patients and their families, erroneous discarding by nursing staff, erroneous discarding by medical staff, cleaning drivers pierced by sharp articles, cleaning staff pierced by sharp articles, and unmarked output units. Therefore, the study concluded that it was necessary to (1) provide education and training about waste classification to the medical staff, patients and their families, nursing staff, and cleaning staff; (2) clarify the signs of caution; and (3) evaluate the failure mode and strengthen the effects.« less
Whole bone mechanics and bone quality.
Cole, Jacqueline H; van der Meulen, Marjolein C H
2011-08-01
The skeleton plays a critical structural role in bearing functional loads, and failure to do so results in fracture. As we evaluate new therapeutics and consider treatments to prevent skeletal fractures, understanding the basic mechanics underlying whole bone testing and the key principles and characteristics contributing to the structural strength of a bone is critical. We therefore asked: (1) How are whole bone mechanical tests performed and what are the key outcomes measured? (2) How do the intrinsic characteristics of bone tissue contribute to the mechanical properties of a whole bone? (3) What are the effects of extrinsic characteristics on whole bone mechanical behavior? (4) Do environmental factors affect whole bone mechanical properties? We conducted a PubMed search using specific search terms and limiting our included articles to those related to in vitro testing of whole bones. Basic solid mechanics concepts are summarized in the context of whole bone testing and the determinants of whole bone behavior. Whole bone mechanical tests measure structural stiffness and strength from load-deformation data. Whole bone stiffness and strength are a function of total bone mass and the tissue geometric distribution and material properties. Age, sex, genetics, diet, and activity contribute to bone structural performance and affect the incidence of skeletal fractures. Understanding and preventing skeletal fractures is clinically important. Laboratory tests of whole bone strength are currently the only measures for in vivo fracture prediction. In the future, combined imaging and engineering models may be able to predict whole bone strength noninvasively.
Organ protection possibilities in acute heart failure.
Montero-Pérez-Barquero, M; Morales-Rull, J L
2016-04-01
Unlike chronic heart failure (HF), the treatment for acute HF has not changed over the last decade. The drugs employed have shown their ability to control symptoms but have not achieved organ protection or managed to reduce medium to long-term morbidity and mortality. Advances in our understanding of the pathophysiology of acute HF suggest that treatment should be directed not only towards correcting the haemodynamic disorders and achieving symptomatic relief but also towards preventing organ damage, thereby counteracting myocardial remodelling and cardiac and extracardiac disorders. Compounds that exert vasodilatory and anti-inflammatory action in the acute phase of HF and can stop cell death, thereby boosting repair mechanisms, could have an essential role in organ protection. Copyright © 2016 Elsevier España, S.L.U. y Sociedad Española de Medicina Interna (SEMI). All rights reserved.
Application of Risk-Based Inspection method for gas compressor station
NASA Astrophysics Data System (ADS)
Zhang, Meng; Liang, Wei; Qiu, Zeyang; Lin, Yang
2017-05-01
According to the complex process and lots of equipment, there are risks in gas compressor station. At present, research on integrity management of gas compressor station is insufficient. In this paper, the basic principle of Risk Based Inspection (RBI) and the RBI methodology are studied; the process of RBI in the gas compressor station is developed. The corrosion loop and logistics loop of the gas compressor station are determined through the study of corrosion mechanism and process of the gas compressor station. The probability of failure is calculated by using the modified coefficient, and the consequence of failure is calculated by the quantitative method. In particular, we addressed the application of a RBI methodology in a gas compressor station. The risk ranking is helpful to find the best preventive plan for inspection in the case study.
Failure mechanisms of uni-ply composite plates with a circular hole under static compressive loading
NASA Technical Reports Server (NTRS)
Khamseh, A. R.; Waas, A. M.
1992-01-01
The objective of the study was to identify and study the failure mechanisms associated with compressive-loaded uniply graphite/epoxy square plates with a central circular hole. It is found that the type of compressive failure depends on the hole size. For large holes with the diameter/width ratio exceeding 0.062, fiber buckling/kinking initiated at the hole is found to be the dominant failure mechanism. In plates with smaller hole sizes, failure initiates away from the hole edge or complete global failure occurs. Critical buckle wavelengths at failure are presented as a function of the normalized hole diameter.
Experimental methods for identifying failure mechanisms
NASA Technical Reports Server (NTRS)
Daniel, I. M.
1983-01-01
Experimental methods for identifying failure mechanisms in fibrous composites are studied. Methods to identify failure in composite materials includes interferometry, holography, fractography and ultrasonics.
Preventing Early Reading Failure: An Argument
ERIC Educational Resources Information Center
Morris, Darrell
2015-01-01
Across the pendulum-like changes in beginning reading instruction over the past 30 years, three interrelated ideas emerge as the key to preventing reading failure in kindergarten and first grade: (1) an interesting, carefully-leveled book curriculum; (2) a leveled phonics curriculum; and (3) a well-trained teacher who knows how to integrate guided…
Prediction and prevention of failure: an early intervention to assist at-risk medical students.
Winston, Kalman A; van der Vleuten, Cees P M; Scherpbier, Albert J J A
2014-01-01
Consistent identification and prevention of failure for at-risk medical students is challenging, failing courses is costly to all stakeholders, and there is need for further research into duration, timing and structure of interventions to help students in difficulty. To verify the value of a new exam two weeks into medical school as a predictor of failure, and explore the requirements for a preventative intervention. Students who failed the two-week exam were invited to a series of large-group workshops and small-group follow-up meetings. Participants' subsequent exam performance was compared with non-participants. About 71% of students who performed poorly in the new exam subsequently failed a course. Attendance at the workshops made no difference to short- or long-term pass rates. Attendance at more than three follow-up small group sessions significantly improved pass rates two semesters later, and was influenced by teacher experience. Close similarity between predictor task and target task is important for accurate prediction of failure. Consideration should be given to dose effect and class size in the prevention of failure of at-risk students, and we recommend a systemic approach to intervention/remediation programmes, involving a whole semester of mandatory, weekly small group meetings with experienced teachers.
Zakkar, Mustafa; Kanagasabay, Robin; Hunt, Ian
2014-01-01
A best evidence topic in cardiothoracic surgery was written according to a structured protocol. The question addressed was whether manual closure of the bronchial stump is safer with lower failure rates than mechanical closure using a stapling device following anatomical lung resection. One hundred and twenty-nine papers were identified using the search below. Eight papers presented the best evidence to answer the clinical question as they included sufficient number of patients to reach conclusions regarding the issues of interest for this review. Complications, complication rates and operation time were included in the assessment. The author, journal, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of the papers are tabulated. When looking at manual vs mechanical staples, it was noted that stapler failure can occur in around 4% of cases. The rate of bronchopleural fistula (BPF) development varied more in patients who underwent manual closure (1.5–12.5%) than in patients who underwent mechanical closure (1–5.7%). Although most of the studies reviewed showed no statistical differences between manual and mechanical closure in terms of BPF development, one study, however, showed that manual closure was significantly associated with lower numbers of postoperative BPF, while another study showed that mechanical closure is significantly associated with lower incidence of BPF. When looking at the role of the learning curve and training opportunities, it seems that the surgeon's inexperience when using mechanical staples can contribute to BPF development. A surgeon's experience can play a major role in the prevention of BPF development in patients having manual closure. Manual closure can provide a cheap and reliable technique when compared with costs incurred from using staplers, it is applicable in all situations and can be taught to surgeons in training with an acceptable risk. However, there is a lack of evidence to suggest that manual closure is better than mechanical stapler closure following anatomical lung resection. PMID:24351508
RAS blockade with ARB and ACE inhibitors: current perspective on rationale and patient selection.
Werner, Christian; Baumhäkel, Magnus; Teo, Koon K; Schmieder, Roland; Mann, Johannes; Unger, Thomas; Yusuf, Salim; Böhm, Michael
2008-07-01
Cardiovascular disease represents a continuum that starts with risk factors such as hypertension and progresses to atherosclerosis, target organ damage, and ultimately to myocardial infarction, heart failure, stroke or death. Renin-angiotensin system (RAS) blockade with angiotensin converting enzyme (ACE) inhibitors or angiotensin AT(1)-receptor blockers (ARBs) has turned out to be beneficial at all stages of this continuum. Both classes of agent can prevent or reverse endothelial dysfunction and atherosclerosis, thereby reducing the risk of cardiovascular events. Such a reduction has been shown mainly for ACE inhibitors in patients with coronary artery disease, but recent studies revealed that ARBs are not inferior in this respect. However, no such data are currently available on the combination of these drugs. Both ACE inhibitors and ARBs have been shown to reduce target organ damage in organs such as the kidney, brain and heart, and to decrease cardiovascular mortality and morbidity in patients with congestive heart failure. Experimental data point to an influence of ACE inhibitors and ARBs on the number and function of endothelial progenitor cells revealing additional mechanisms of action of these drugs. The VALIANT trial has shown equivalent effects of ARB valsartan and the ACE-inhibitor captopril in patients post myocardial infarction, but the dual RAS-blockade, compared to monotherapy, did not further reduce events. In secondary prevention, the most-recently published ONTARGET study provides evidence that on top of a better tolerability AT(1)-receptors antagonists are equal to ACE inhibitors in the prevention of clinical endpoints like cardiovascular mortality and morbidity, myocardial infarction and stroke. The combined RAS blockade, however, achieved no further benefits in vascular high-risk patients and was associated with more adverse events. In chronic heart failure, ValHeFT and CHARM-ADDED have shown that combined RAS inhibition with ACE inhibitor and valsartan or candesartan reduced morbidity and mortality in certain patient subgroups. Accumulating evidence also points to benefits of the combination therapy in individuals with proteinuric nephropathies. In conclusion, while combined RAS-inhibition is not generally indicated in patients along the cardio-reno-vascular continuum, it has already proven to be effective in heart failure patients with incomplete neuroendocrine blockade. In secondary prevention, monotherapy with either RAS inhibitor is equally efficacious. Furthermore, novel pharmacologic agents such as renin inhibitors may prove useful in preventing common side effects of RAS blockade such as angiotensin escape and AT(1)-receptor upregulation, giving clinicians additional therapeutic tools to optimally treat the individual patient.
Wang, Yixin; Jin, Yi; Mäe, Maarja Andaloussi; Zhang, Yang; Ortsäter, Henrik; Betsholtz, Christer; Mäkinen, Taija; Jakobsson, Lars
2017-10-01
Tissue fluid drains through blind-ended lymphatic capillaries, via smooth muscle cell (SMC)-covered collecting vessels into venous circulation. Both defective SMC recruitment to collecting vessels and ectopic recruitment to lymphatic capillaries are thought to contribute to vessel failure, leading to lymphedema. However, mechanisms controlling lymphatic SMC recruitment and its role in vessel maturation are unknown. Here, we demonstrate that platelet-derived growth factor B (PDGFB) regulates lymphatic SMC recruitment in multiple vascular beds. PDGFB is selectively expressed by lymphatic endothelial cells (LECs) of collecting vessels. LEC-specific deletion of Pdgfb prevented SMC recruitment causing dilation and failure of pulsatile contraction of collecting vessels. However, vessel remodelling and identity were unaffected. Unexpectedly, Pdgfb overexpression in LECs did not induce SMC recruitment to capillaries. This was explained by the demonstrated requirement of PDGFB extracellular matrix (ECM) retention for lymphatic SMC recruitment, and the low presence of PDGFB-binding ECM components around lymphatic capillaries. These results demonstrate the requirement of LEC-autonomous PDGFB expression and retention for SMC recruitment to lymphatic vessels, and suggest an ECM-controlled checkpoint that prevents SMC investment of capillaries, which is a common feature in lymphedematous skin. © 2017. Published by The Company of Biologists Ltd.
Ghorbani Kashkooli, Ali; Foreman, Evan; Farhad, Siamak; ...
2017-07-18
Here in this study, synchrotron X-ray nano-computed tomography at Advanced Photon Source in Argonne National Laboratory has been employed to reconstruct real 3D active particle morphology of LiMn 2O 4 (LMO) commonly used in lithium-ion batteries (LIBs). For the first time, carbon-doped binder domain (CBD) has been included in the electrode structure as a 108 nm thick uniform layer using image processing technique. With this unique model, stress generated inside four LMO particles with a uniform layer of CBD has been simulated, demonstrating its strong dependence on local morphology (surface concavity and convexity), and the mechanical properties of CBD suchmore » as Young’s modulus. Specifically, high levels of stress have been found in vicinity of particle’s center or near surface concave regions, however much lower than the material failure limits even after discharging at the rate as high as 5C. On the other hand, the stress inside CBD has reached its mechanical limits when discharged at 5C, suggesting that it can potentially lead to failure by plastic deformation. The findings in this study highlight the importance of modeling LIB active particles with CBD and its appropriate compositional design and development to prevent the loss of electrical connectivity of the active particles from the percolated solid network and power losses due to CBD failure.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghorbani Kashkooli, Ali; Foreman, Evan; Farhad, Siamak
Here in this study, synchrotron X-ray nano-computed tomography at Advanced Photon Source in Argonne National Laboratory has been employed to reconstruct real 3D active particle morphology of LiMn 2O 4 (LMO) commonly used in lithium-ion batteries (LIBs). For the first time, carbon-doped binder domain (CBD) has been included in the electrode structure as a 108 nm thick uniform layer using image processing technique. With this unique model, stress generated inside four LMO particles with a uniform layer of CBD has been simulated, demonstrating its strong dependence on local morphology (surface concavity and convexity), and the mechanical properties of CBD suchmore » as Young’s modulus. Specifically, high levels of stress have been found in vicinity of particle’s center or near surface concave regions, however much lower than the material failure limits even after discharging at the rate as high as 5C. On the other hand, the stress inside CBD has reached its mechanical limits when discharged at 5C, suggesting that it can potentially lead to failure by plastic deformation. The findings in this study highlight the importance of modeling LIB active particles with CBD and its appropriate compositional design and development to prevent the loss of electrical connectivity of the active particles from the percolated solid network and power losses due to CBD failure.« less
Mechanical behavior and failure mechanisms of Li-ion battery separators
Kalnaus, Sergiy; Wang, Yanli; Turner, John A.
2017-03-09
We determine and compare anisotropic mechanical properties for three types of commercially available Li-ion battery separators: Celgard 2325, Celgard PP2075 dry-processed polymer separators, and DreamWeaver Gold 40 non-woven separator. Significant amount of anisotropy of properties was determined, with the Young's modulus being different by up to a factor of 5 and ultimate strength being different by a factor of 10 between orthogonal directions within a polymer separator layer. Strain rate sensitivity was investigated by applying strain rates ranging from 1•10 -4 s -1 to 0.1 s -1. Significant strengthening was observed and the strain rate strengthening coefficients were determined formore » both elastic modulus and yield stress in case of polymer separators. Digital image correlation technique was used to measure and map the strains over the specimen's gage section. A significant strain concentration in bands running perpendicular to the tensile axis was observed in polymer separator samples oriented in transverse direction. Such localized necking allows for extremely high strains close to 300% to develop in the material. Furthermore, the failure mode was remarkably different for all three types of separators which adds additional variable in safe design of Li-ion batteries for prevention of internal short circuits.« less
Biaxial Response of Passive Human Cerebral Arteries
Monson, Kenneth L.; Barbaro, Nicholas M.; Manley, Geoffrey T.
2008-01-01
The cerebral circulation is fundamental to the health and maintenance of brain tissue, but injury and disease may result in dysfunction of the vessels. Characterization of cerebral vessel mechanical response is an important step toward a more complete understanding of injury mechanisms and disease development in these vessels, paving the way for improved prevention and treatment. We recently reported a large series of uniaxial tests on fresh human cerebral vessels, but the multi-axial behavior of these vessels has not been previously described. Twelve arteries were obtained from the surface of the temporal lobe of patients undergoing surgery and were subjected to various combinations of axial stretch and pressure around typical physiological conditions before being stretched to failure. Axial and circumferential responses were compared, and measured data were fit to a four parameter, Fung-type hyperelastic constitutive model. Artery behavior was nonlinear and anisotropic, with considerably greater resistance to deformation in the axial direction than around the circumference. Results from axial failure tests of pressurized vessels resulted in a small shift in stress-stretch response compared to previously reported data from unpressurized specimens. These results further define the biaxial response of the cerebral arteries and provide data required for more rigorous study of head injury mechanisms and development of cerebrovascular disease. PMID:18855141
[Tobacco control from an economic perspective].
López Nicolás, Angel; Viudes de Velasco, Arántzazu
2009-01-01
This paper reviews the main arguments put forward from Economics in the area of tobacco control, and provides a detailed description of market failures from both the traditional perspective and recent literature advances. It concludes that smoking is a personal choice that can generate net welfare losses for the society, the smokers family and, above, all the smoker him(her)self. On these grounds there exists economic justification for correcting mechanisms. The article includes a discussion of two important preventive policies in the Spanish context: restrictions in bars and restaurants and tobacco tax hikes.
Thermomechanical CSM analysis of a superheater tube in transient state
NASA Astrophysics Data System (ADS)
Taler, Dawid; Madejski, Paweł
2011-12-01
The paper presents a thermomechanical computational solid mechanics analysis (CSM) of a pipe "double omega", used in the steam superheaters in circulating fluidized bed (CFB) boilers. The complex cross-section shape of the "double omega" tubes requires more precise analysis in order to prevent from failure as a result of the excessive temperature and thermal stresses. The results have been obtained using the finite volume method for transient state of superheater. The calculation was carried out for the section of pipe made of low-alloy steel.
Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K
2010-09-01
Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.
Failure analysis of blistered gold plating on spot welded electrical relays
NASA Technical Reports Server (NTRS)
Sokolowski, Witold; O'Donnell, Tim
1989-01-01
Gold-plated stainless-steel sideplates, part of a JPL Galileo spacecraft electronic-relay assembly, exhibited blistering after resistance spot welding. Unacceptable relays had heavy nonuniform gold electrodeposited layers with thicknesses 4.5-11.5 microns. SEM and metallographic investigations indicated much higher heat input generated during the resistance spot welding in unacceptable relays. The attributes of acceptable welded relays are contrasted with unacceptable relays; the possible mechanism of laminar formation of polymeric material in the gold plating is discussed; and some recommendations are provided to prevent similar problems.
Possible potassium chlorate nephrotoxicity associated with chronic matchstick ingestion.
Thurlow, John S; Little, Dustin J; Baker, Thomas P; Yuan, Christina M
2013-06-01
We present a case of a 48-year-old active duty male soldier with a history of chronic exposure to potassium chlorate, later diagnosed with chronic interstitial nephritis. He reported regular matchstick consumption to prevent chigger (Trombicula autumnalis) bites, amounting to ∼5.8 g of potassium chlorate over 3 years. Potassium chlorate can cause anuric renal failure within days of a toxic dose. Its slow excretion and mechanism of action suggest that renal toxicity may result from lower-dose chronic exposure. This case represents possible sequelae of chronic potassium chlorate ingestion.
Possible potassium chlorate nephrotoxicity associated with chronic matchstick ingestion*
Thurlow, John S.; Little, Dustin J.; Baker, Thomas P.; Yuan, Christina M.
2013-01-01
We present a case of a 48-year-old active duty male soldier with a history of chronic exposure to potassium chlorate, later diagnosed with chronic interstitial nephritis. He reported regular matchstick consumption to prevent chigger (Trombicula autumnalis) bites, amounting to ∼5.8 g of potassium chlorate over 3 years. Potassium chlorate can cause anuric renal failure within days of a toxic dose. Its slow excretion and mechanism of action suggest that renal toxicity may result from lower-dose chronic exposure. This case represents possible sequelae of chronic potassium chlorate ingestion. PMID:26064493
Structural Continuum Modeling of Space Shuttle External Tank Foam Insulation
NASA Technical Reports Server (NTRS)
Steeve, Brian; Ayala, Sam; Purlee, T. Eric; Shaw, Phillip
2006-01-01
This document is a viewgraph presentation reporting on work in modeling the foam insulation of the Space Shuttle External Tank. An analytical understanding of foam mechanics is required to design against structural failure. The Space Shuttle External Tank is covered primarily with closed cell foam to: Prevent ice, Protect structure from ascent aerodynamic and engine plume heating, and Delay break-up during re-entry. It is important that the foam does not shed unacceptable debris during ascent environment. Therefore a modeling of the foam insulation was undertaken.
Using Rollback Avoidance to Mitigate Failures in Next-Generation Extreme-Scale Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levy, Scott N.
2016-05-01
High-performance computing (HPC) systems enable scientists to numerically model complex phenomena in many important physical systems. The next major milestone in the development of HPC systems is the construction of the rst supercomputer capable executing more than an exa op, 10 18 oating point operations per second. On systems of this scale, failures will occur much more frequently than on current systems. As a result, resilience is a key obstacle to building next-generation extremescale systems. Coordinated checkpointing is currently the most widely-used mechanism for handling failures on HPC systems. Although coordinated checkpointing remains e ective on current systems, increasing themore » scale of today's systems to build next-generation systems will increase the cost of fault tolerance as more and more time is taken away from the application to protect against or recover from failure. Rollback avoidance techniques seek to mitigate the cost of checkpoint/restart by allowing an application to continue its execution rather than rolling back to an earlier checkpoint when failures occur. These techniqes include failure prediction and preventive migration, replicated computation, fault-tolerant algorithms, and softwarebased memory fault correction. In this thesis, we examine how rollback avoidance techniques can be used to address failures on extreme-scale systems. Using a combination of analytic modeling and simulation, we evaluate the potential impact of rollback avoidance on these systems. We then present a novel rollback avoidance technique that exploits similarities in application memory. Finally, we examine the feasibility of using this technique to protect against memory faults in kernel memory.« less
Sari, A Akbari; Doshmangir, L; Sheldon, T
2010-01-01
Understanding the nature and causes of medical adverse events may help their prevention. This systematic review explores the types, risk factors, and likely causes of preventable adverse events in the hospital sector. MEDLINE (1970-2008), EMBASE, CINAHL (1970-2005) and the reference lists were used to identify the studies and a structured narrative method used to synthesise the data. Operative adverse events were more common but less preventable and diagnostic adverse events less common but more preventable than other adverse events. Preventable adverse events were often associated with more than one contributory factor. The majority of adverse events were linked to individual human error, and a significant proportion of these caused serious patient harm. Equipment failure was involved in a small proportion of adverse events and rarely caused patient harm. The proportion of system failures varied widely ranging from 3% to 85% depending on the data collection and classification methods used. Operative adverse events are more common but less preventable than diagnostic adverse events. Adverse events are usually associated with more than one contributory factor, the majority are linked to individual human error, and a proportion of these with system failure.
Compendium of Mechanical Limit-States
NASA Technical Reports Server (NTRS)
Kowal, Michael
1996-01-01
A compendium was compiled and is described to provide a diverse set of limit-state relationships for use in demonstrating the application of probabilistic reliability methods to mechanical systems. The different limit-state relationships can be used to analyze the reliability of a candidate mechanical system. In determining the limit-states to be included in the compendium, a comprehensive listing of the possible failure modes that could affect mechanical systems reliability was generated. Previous literature defining mechanical modes of failure was studied, and cited failure modes were included. From this, classifications for failure modes were derived and are described in some detail.
Dugbartey, George J.; Peppone, Luke J.; de Graaf, Inge A.M.
2017-01-01
Cisplatin is currently one of the most widely-used chemotherapeutic agents against various malignancies. Its clinical application is limited, however, by inherent renal and cardiac toxicities and other side effects, of which the underlying mechanisms are only partly understood. Experimental studies show cisplatin generates reactive oxygen species, which impair the cell’s antioxidant defense system, causing oxidative stress and potentiating injury, thereby culminating in kidney and heart failure. Understanding the molecular mechanisms of cisplatin-induced renal and cardiac toxicities may allow clinicians to prevent or treat this problem better and may also provide a model for investigating drug-induced organ toxicity in general. This review discusses some of the major molecular mechanisms of cisplatin-induced renal and cardiac toxicities including disruption of ionic homeostasis and energy status of the cell leading to cell injury and cell death. We highlight clinical manifestations of both toxicities as well as (novel)biomarkers such as kidney injury molecule-1 (KIM-1), tissue inhibitor of metalloproteinase-1 (TIMP-1) and N-terminal pro-B-type natriuretic peptide (NT-proBNP). We also present some current treatment challenges and propose potential protective strategies with novel pharmacological compounds that might mitigate or prevent these toxicities, which include the use of hydrogen sulfide. PMID:27717837
Kim, Deog Kyeom; Lee, Jungsil; Park, Ju Hee; Yoo, Kwang Ha
2018-04-01
Acute exacerbation(s) of chronic obstructive pulmonary disease (AECOPD) tend to be critical and debilitating events leading to poorer outcomes in relation to chronic obstructive pulmonary disease (COPD) treatment modalities, and contribute to a higher and earlier mortality rate in COPD patients. Besides pro-active preventative measures intended to obviate acquisition of AECOPD, early recovery from severe AECOPD is an important issue in determining the long-term prognosis of patients diagnosed with COPD. Updated GOLD guidelines and recently published American Thoracic Society/European Respiratory Society clinical recommendations emphasize the importance of use of pharmacologic treatment including bronchodilators, systemic steroids and/or antibiotics. As a non-pharmacologic strategy to combat the effects of AECOPD, noninvasive ventilation (NIV) is recommended as the treatment of choice as this therapy is thought to be most effective in reducing intubation risk in patients diagnosed with AECOPD with acute respiratory failure. Recently, a few adjunctive modalities, including NIV with helmet and helium-oxygen mixture, have been tried in cases of AECOPD with respiratory failure. As yet, insufficient documentation exists to permit recommendation of this therapy without qualification. Although there are too few findings, as yet, to allow for regular andr routine application of those modalities in AECOPD, there is anecdotal evidence to indicate both mechanical and physiological benefits connected with this therapy. High-flow nasal cannula oxygen therapy is another supportive strategy which serves to improve the symptoms of hypoxic respiratory failure. The therapy also produced improvement in ventilatory variables, and it may be successfully applied in cases of hypercapnic respiratory failure. Extracorporeal carbon dioxide removal has been successfully attempted in cases of adult respiratory distress syndrome, with protective hypercapnic ventilatory strategy. Nowadays, it is reported that it was also effective in reducing intubation in AECOPD with hypercapnic respiratory failure. Despite the apparent need for more supporting evidence, efforts to improve efficacy of NIV have continued unabated. It is anticipated that these efforts will, over time, serve toprogressively decrease the risk of intubation and invasive mechanical ventilation in cases of AECOPD with acute respiratory failure. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.
Boermeester, M. A.; Houdijk, A. P.; Meyer, S.; Cuesta, M. A.; Appelmelk, B. J.; Wesdorp, R. I.; Hack, C. E.; Van Leeuwen, P. A.
1995-01-01
The observed increased susceptibility of patients with fulminant hepatic failure for local and systemic infections has been hypothesized to be due to a failure for the hepatic clearance function and subsequent leaking of endogenous endotoxins into the systemic circulation. However, experimental evidence for such a systemic inflammation during liver failure due to endogenous endotoxemia is lacking. Therefore, we designed a study to clarify whether circulating endotoxins due to liver failure could lead to the development of systemic inflammations. In a rat model for liver failure induced by a two-thirds partial hepatectomy, we evaluated the course of circulating tumor necrosis factor and interleukin-6, changes in blood chemistry and hemodynamics, and histopathological changes in the lungs. Partially hepatectomized animals, but not sham-operated animals, demonstrated cardiac failure, increased levels of creatinin and urea, metabolic acidosis, high plasma levels of tumor necrosis factor and interleukin-6, and an influx of PMNs in the lungs-together indicating the development of a systemic inflammatory response. Continuous infusion of recombinant N-terminal bactericidal/permeability-increasing protein (rBPI23), a well described endotoxin-neutralizing protein, prevented these inflammatory reactions. Ex vivo experiments with rat plasma samples confirmed the presence of circulating endotoxins in partially hepatectomized rats as opposed to those treated with rBPI23. Thus, our results indicate that the early phase of liver failure induces a systemic inflammatory response triggered by circulating endotoxins, which can be prevented by perioperative infusion of rBPI23. Images Figure 2 PMID:7485405
76 FR 79051 - Airworthiness Directives; Lycoming Engines, Fuel Injected Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-21
... models requiring inspections. We are issuing this AD to prevent failure of the fuel injector fuel lines... to prevent failure of the fuel injector fuel lines that would allow fuel to spray into the engine... injector nozzles, and replace as necessary any fuel injector fuel line and clamp that does not meet all...
Fogel, Jessica M; Hudelson, Sarah E; Ou, San-San; Hart, Stephen; Wallis, Carole; Morgado, Mariza G; Saravanan, Shanmugam; Tripathy, Srikanth; Hovind, Laura; Piwowar-Manning, Estelle; Sabin, Devin; McCauley, Marybeth; Gamble, Theresa; Zhang, Xinyi C; Eron, Joseph J; Gallant, Joel E; Kumwenda, Johnstone; Makhema, Joseph; Kumarasamy, Nagalingeswaran; Chariyalertsak, Suwat; Hakim, James; Badal-Faesen, Sharlaa; Akelo, Victor; Hosseinipour, Mina C; Santos, Breno R; Godbole, Sheela V; Pilotto, Jose H; Grinsztejn, Beatriz; Panchia, Ravindre; Mayer, Kenneth H; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H
2016-07-01
Early initiation of antiretroviral treatment (ART) reduces HIV transmission and has health benefits. HIV drug resistance can limit treatment options and compromise use of ART for HIV prevention. We evaluated drug resistance in 85 participants in the HIV Prevention Trials Network 052 trial who started ART at CD4 counts of 350-550 cells per cubic millimeter and failed ART by May 2011; 8.2% had baseline resistance and 35.3% had resistance at ART failure. High baseline viral load and less education were associated with emergence of resistance at ART failure. Resistance at ART failure was observed in 7 of 8 (87.5%) participants who started ART at lower CD4 cell counts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dvorak, G.J.
1974-10-01
The research effort was concentrated on metal matrix composites, such as the Al--B, Al--Be, Cu--W, and similar systems. It was found that in as- fabricated composites with soft matrices fatigue failure can be prevented if the composite shakes down during cyclic loading. The fatigue strength of heat- treated composites is affected by residual microstresses, but failure can be prevented if the total microstresses are kept within the respective fatigue limits (at 10 to the 7th power cycles) of the constituents. These criteria for prevention of fatigue failure in metal matrix composite systems were verified by extensive comparisons of theoretical predictionsmore » with available experimental results. (GRA)« less
[PATHOPHYSIOLOGY OF THE CARDIORENAL SYNDROME].
Balint, I; Vučak, J; Bašić-Marković, N; Klarić, D; Šakić, V Amerl
2016-12-01
Cardiorenal syndrome, a complex pathophysiological disorder of both the heart and kidneys, is a condition in which acute or chronic damage to one organ can lead to acute or chronic dysfunction of the other organ. Depending on primary organ dysfunction and disease duration, there are five different types of cardiorenal syndrome. Type 1 cardiorenal syndrome (acute cardiorenal syndrome) is defined as acute kidney injury caused by sudden decrease in heart function. Type 2 cardiorenal syndrome (chronic cardiorenal syndrome) refers to chronic kidney disease linked to chronic heart failure. Type 3 cardiorenal syndrome (acute renocardial syndrome) is caused by acute kidney injury that leads to heart failure. Type 4 cardiorenal syndrome (chronic renocardial syndrome) includes chronic heart failure due to chronic kidney disease. Type 5 cardiorenal syndrome (secondary cardiorenal syndrome) is reversible or irreversible condition marked by simultaneous heart and kidney insufficiency, as a result of multiorgan disease such as sepsis, diabetes mellitus, sarcoidosis, amyloidosis, etc. The pathophysiological patterns of cardiorenal syndrome are extremely complicated. Despite numerous publications, perplexed physiological, biochemical and hormonal disturbances as parts of the main pathogenic mechanisms of cardiorenal syndrome remain obscure. Even though there are guidelines for the treatment of patients with heart failure and chronic kidney disease, similar guidelines for the treatment of cardiorenal syndrome are lacking. In everyday practice, it is crucial to diagnose cardiorenal syndrome and use all diagnostic and therapeutic procedures available to prevent or alleviate kidney and heart failure.
Factors affecting proppant flowback with resin coated proppants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almond, S.W.; Penny, G.S.; Conway, M.W.
1995-12-31
Resin coated proppants (RCPs) have been used to prevent proppant flowback for several years in the hydraulic fracturing of oil and gas wells. Proppant flowback problems, however, still exist with the commercially available RCPs and several operators report failures around the world under a variety of well conditions. To date, a clear explanation of the RCP failure mechanisms and the conditions under which failure occurs has not been presented in the industry. A correlation between the unconfined compressive strength (UCS) of RCP materials and the proppant flowback potential has been previously presented by Vreeburg, et al. This paper will presentmore » the results of a study on a variety of factors which effect the proppant flowback of a number of commercially available RCP materials. These factors include (1) the effect of fluid pH (7 to 12) and fluid type (KCL, seawater and a HPG/Borate fracturing fluid), (2) the effect of fluid/proppant slurry shear, (3) the effect of closure pressure during RCP curing, (4) the effect of stress cycling and (5) the effect of downhole flow conditions on proppant flowback.« less
A new "twist" on right heart failure with left ventricular assist systems.
Houston, Brian A; Shah, Keyur B; Mehra, Mandeep R; Tedford, Ryan J
2017-07-01
Despite significant efforts to predict and prevent right heart failure, it remains a leading cause of morbidity and mortality after implantation of left ventricular assist systems (LVAS). In this Perspective, we review the underappreciated anatomic and physiologic principles that govern the relationship between left and right heart function and contribute to this phenomenon. This includes the importance of considering the right ventricle (RV) and pulmonary arterial circuit as a coupled system; the contribution of the left ventricle (LV) to RV contractile function and the potential negative impact of acutely unloading the LV; the influence of the pericardium and ventricular twist on septal function; the role of RV deformation in reduced mechanical efficiency after device placement; and the potential of ongoing stressors of an elevated right-sided preload. We believe an appreciation of these complex issues is required to fully understand the expression of the unique phenotypes of right heart failure after LVAS implantation and for developing better prognostic and therapeutic strategies. Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Compression failure mechanisms of uni-ply composite plates with a circular cutout
NASA Technical Reports Server (NTRS)
Khamseh, A. R.; Waas, A. M.
1992-01-01
The effect of circular-hole size on the failure mode of uniply graphite-epoxy composite plates is investigated experimentally and analytically for uniaxial compressive loading. The test specimens are sandwiched between polyetherimide plastic for nondestructive evaluations of the uniply failure mechanisms associated with a range of hole sizes. Finite-element modeling based on classical lamination theory is conducted for the corresponding materials and geometries to reproduce the experimental results analytically. The type of compressive failure is found to be a function of hole size, with fiber buckling/kinking at the hole being the dominant failure mechanism for hole diam/plate width ratios exceeding 0.062. The results of the finite-element analysis supported the experimental data for these failure mechanisms and for those corresponding to smaller hole sizes.
NASA Technical Reports Server (NTRS)
Gibbel, Mark; Larson, Timothy
2000-01-01
An Engineering-of-Failure approach to designing and executing an accelerated product qualification test was performed to support a risk assessment of a "work-around" necessitated by an on-orbit failure of another piece of hardware on the Mars Global Surveyor spacecraft. The proposed work-around involved exceeding the previous qualification experience both in terms of extreme cold exposure level and in terms of demonstrated low cycle fatigue life for the power shunt assemblies. An analysis was performed to identify potential failure sites, modes and associated failure mechanisms consistent with the new use conditions. A test was then designed and executed which accelerated the failure mechanisms identified by analysis. Verification of the resulting failure mechanism concluded the effort.
Hori, Yukio; Kato, Koji
2008-01-01
In high speed rotating machines such as turbines and generators, vibrations of a rotating shaft often hinder the smooth operation of the machine or even cause failure. Oil whip is one of such vibrations due to oil film action of journal bearing. Its mechanism and preventive method is explained and proposed in this paper. Further theoretical and experimental analyses are made for considering heat generation and temperature rise in hydrodynamic lubrication. The usefulness of the lubrication theory based on the k–ε model is also shown for bearings with high eccentricity ratios. In the latter half of this paper, water lubrication, nitrogen gas lubrication and tribo-coated indium lubrication are shown as new promising methods, and their mechanisms are discussed and the importance of tribo-layer is explained. Some mechanisms of wear are introduced for better understanding of tribo-layer. In the last part of this paper, the mechanisms of generating static friction are shown for the cases of plastic contact and elastic contact, which is the base for understanding the mechanism of initiation of macroscopic sliding. PMID:18941304
Hori, Yukio; Kato, Koji
2008-01-01
In high speed rotating machines such as turbines and generators, vibrations of a rotating shaft often hinder the smooth operation of the machine or even cause failure. Oil whip is one of such vibrations due to oil film action of journal bearing. Its mechanism and preventive method is explained and proposed in this paper. Further theoretical and experimental analyses are made for considering heat generation and temperature rise in hydrodynamic lubrication. The usefulness of the lubrication theory based on the k-epsilon model is also shown for bearings with high eccentricity ratios. In the latter half of this paper, water lubrication, nitrogen gas lubrication and tribo-coated indium lubrication are shown as new promising methods, and their mechanisms are discussed and the importance of tribo-layer is explained. Some mechanisms of wear are introduced for better understanding of tribo-layer. In the last part of this paper, the mechanisms of generating static friction are shown for the cases of plastic contact and elastic contact, which is the base for understanding the mechanism of initiation of macroscopic sliding.
Effect of DGPS failures on dynamic positioning of mobile drilling units in the North Sea.
Chen, Haibo; Moan, Torgeir; Verhoeven, Harry
2009-11-01
Basic features of differential global positioning system (DGPS), and its operational configuration on dynamically positioned (DP) mobile offshore drilling units in the North Sea are described. Generic failure modes of DGPS are discussed, and a critical DGPS failure which has the potential to cause drive-off for mobile drilling units is identified. It is the simultaneous erroneous position data from two DGPS's. Barrier method is used to analyze this critical DGPS failure. Barrier elements to prevent this failure are identified. Deficiencies of each barrier element are revealed based on the incidents and operational experiences in the North Sea. Recommendations to strengthen these barrier elements, i.e. to prevent erroneous position data from DGPS, are proposed. These recommendations contribute to the safety of DP operations of mobile offshore drilling units.
Detection of structural deterioration and associated airline maintenance problems
NASA Technical Reports Server (NTRS)
Henniker, H. D.; Mitchell, R. G.
1972-01-01
Airline operations involving the detection of structural deterioration and associated maintenance problems are discussed. The standard approach to the maintenance and inspection of aircraft components and systems is described. The frequency of inspections and the application of preventive maintenance practices are examined. The types of failure which airline transport aircraft encounter and the steps taken to prevent catastrophic failure are reported.
Doxorubicin (DOX) is an effective drug for treating cancers ranging from leukemia and lymphoma to solid tumors, such as breast cancer. DOX kills dividing cells in two ways: inserting between the base pairs of DNA and trapping a complex of DNA and an enzyme that cuts DNA, topoisomerase 2α, preventing DNA repair. However, DOX also causes congestive heart failure in about 30 percent of adult cancer patients and delayed onset heart failure in a significant number of pediatric cancer patients. The mechanism of this DOX-mediated cardiotoxicity is not well understood since heart muscle cells neither divide nor express Top2α, and there are currently no genetic factors that identify patients who are susceptible to cardiac damage from DOX. However, a recent study showed that mice lacking another topoisomerase, Top2β, did not experience cardiac damage after treatment with DOX.
NASA-DoD Lower Process Temperature Lead-Free Solder Project Overview
NASA Technical Reports Server (NTRS)
Kessel, Kurt R.
2014-01-01
This project is a follow-on effort to the Joint Council on Aging AircraftJoint Group on Pollution Prevention (JCAAJG-PP) Pb-free Solder Project and NASA-DoD Lead-Free Electronics Project which were the first projects to test the reliability of Pb-free solder joints against the requirements of the aerospace and military community. This effort would continue to build on the results from the JCAAJG-PP Lead-Free Solder Project and NASA-DoD Lead-Free Electronics Project while focusing on a particular failure mechanism currently plaguing Pb-free assemblies, pad cratering.The NASA-DoD Lead-Free Electronics Project confirmed that pad cratering is one of the dominant failure modes that occur in various board level reliability tests, especially under dynamic loading. Pad Cratering is a latent defect that may occur during assembly, rework, and post assembly handling and testing.
Fluorescence and UV-vis Spectroscopy of Synovial Fluids
NASA Astrophysics Data System (ADS)
Pinti, Marie J.; Stojilovic, Nenad; Kovacik, Mark W.
2009-10-01
Total joint arthroplasty involves replacing the worn cartilaginous surfaces of the joint with man-made materials that are designed to be biocompatible and to withstand mechanical stresses. Commonly these bearing materials consist of metallic alloys (TiAlV or CoCrMo) and UHMWPE. Following joint arthroplasty, the normal generation of micro-metallic wear debris particles that dislodge from the prosthesis has been shown to cause inflammatory aseptic osteolysis (bone loss) that ultimately results in the failure of the implant. Here we report our results on the novel use of Fluorescence and UV-vis spectroscopy to investigate the metallic content of synovial fluid specimens taken from postoperative total knee arthroplasties. Preliminary finding showed presence of alumina and chromium is some specimens. The ability to detect and monitor the wear rate of these implants could have far reaching implications in the prevention of metallic wear-debris induced osteolysis and impending implant failure.
Reducing myocardial infarct size: challenges and future opportunities
Bulluck, Heerajnarain; Yellon, Derek M; Hausenloy, Derek J
2016-01-01
Despite prompt reperfusion by primary percutaneous coronary intervention (PPCI), the mortality and morbidity of patients presenting with an acute ST-segment elevation myocardial infarction (STEMI) remain significant with 9% death and 10% heart failure at 1 year. In these patients, one important neglected therapeutic target is ‘myocardial reperfusion injury’, a term given to the cardiomyocyte death and microvascular dysfunction which occurs on reperfusing ischaemic myocardium. A number of cardioprotective therapies (both mechanical and pharmacological), which are known to target myocardial reperfusion injury, have been shown to reduce myocardial infarct (MI) size in small proof-of-concept clinical studies—however, being able to demonstrate improved clinical outcomes has been elusive. In this article, we review the challenges facing clinical cardioprotection research, and highlight future therapies for reducing MI size and preventing heart failure in patients presenting with STEMI at risk of myocardial reperfusion injury. PMID:26674987
Robust holographic storage system design.
Watanabe, Takahiro; Watanabe, Minoru
2011-11-21
Demand is increasing daily for large data storage systems that are useful for applications in spacecraft, space satellites, and space robots, which are all exposed to radiation-rich space environment. As candidates for use in space embedded systems, holographic storage systems are promising because they can easily provided the demanded large-storage capability. Particularly, holographic storage systems, which have no rotation mechanism, are demanded because they are virtually maintenance-free. Although a holographic memory itself is an extremely robust device even in a space radiation environment, its associated lasers and drive circuit devices are vulnerable. Such vulnerabilities sometimes engendered severe problems that prevent reading of all contents of the holographic memory, which is a turn-off failure mode of a laser array. This paper therefore presents a proposal for a recovery method for the turn-off failure mode of a laser array on a holographic storage system, and describes results of an experimental demonstration. © 2011 Optical Society of America
Causes of Coal Mine Accidents in the World and Turkey.
Küçük, Filiz Çağla Uyanusta; Ilgaz, Aslıhan
2015-04-01
Occupational accidents and occupational diseases are common in the mining sector in Turkey and throughout the world. The most common causes of accidents in coal mining are firedamp and dust explosions, landslips, mine fires, and technical failures related to transport and mechanization. An analysis of occupational accidents in the consideration of social and economic factors will let understand the real causes behind these accidents, which are said to happen inevitably due to technical deficiencies or failures. Irregular working conditions, based on profit maximization and cost minimization, are related to strategic operational preferences and public policies. Proving that accidents in mines, where occupational health and safety measures are not implemented and inspections are not done properly or at all, are caused by the fact that production is imposed to be carried out in the fastest, cheapest, and most profitable way will allow us to take steps to prevent further mine accidents.
Causes of Coal Mine Accidents in the World and Turkey
Küçük, Filiz Çağla Uyanusta; Ilgaz, Aslıhan
2015-01-01
Occupational accidents and occupational diseases are common in the mining sector in Turkey and throughout the world. The most common causes of accidents in coal mining are firedamp and dust explosions, landslips, mine fires, and technical failures related to transport and mechanization. An analysis of occupational accidents in the consideration of social and economic factors will let understand the real causes behind these accidents, which are said to happen inevitably due to technical deficiencies or failures. Irregular working conditions, based on profit maximization and cost minimization, are related to strategic operational preferences and public policies. Proving that accidents in mines, where occupational health and safety measures are not implemented and inspections are not done properly or at all, are caused by the fact that production is imposed to be carried out in the fastest, cheapest, and most profitable way will allow us to take steps to prevent further mine accidents. PMID:29404108
Conesa-Muñoz, Jesús; Gonzalez-de-Soto, Mariano; Gonzalez-de-Santos, Pablo; Ribeiro, Angela
2015-03-05
This paper describes a supervisor system for monitoring the operation of automated agricultural vehicles. The system analyses all of the information provided by the sensors and subsystems on the vehicles in real time and notifies the user when a failure or potentially dangerous situation is detected. In some situations, it is even able to execute a neutralising protocol to remedy the failure. The system is based on a distributed and multi-level architecture that divides the supervision into different subsystems, allowing for better management of the detection and repair of failures. The proposed supervision system was developed to perform well in several scenarios, such as spraying canopy treatments against insects and diseases and selective weed treatments, by either spraying herbicide or burning pests with a mechanical-thermal actuator. Results are presented for selective weed treatment by the spraying of herbicide. The system successfully supervised the task; it detected failures such as service disruptions, incorrect working speeds, incorrect implement states, and potential collisions. Moreover, the system was able to prevent collisions between vehicles by taking action to avoid intersecting trajectories. The results show that the proposed system is a highly useful tool for managing fleets of autonomous vehicles. In particular, it can be used to manage agricultural vehicles during treatment operations.
Long, Rose G; Bürki, Alexander; Zysset, Philippe; Eglin, David; Grijpma, Dirk W.; Blanquer, Sebastien BG; Hecht, Andrew C; Iatridis, James C
2015-01-01
Unrepaired defects in the annulus fibrosus of intervertebral discs are associated with degeneration and persistent back pain. A clinical need exists for a disc repair strategy that can seal annular defects, be easily delivered during surgical procedures, and restore biomechanics with low risk of herniation. Multiple annulus repair strategies were developed using poly(trimethylene carbonate) scaffolds optimized for cell delivery, polyurethane membranes designed to prevent herniation, and fibrin-genipin adhesive tuned to annulus fibrosus shear properties. This three-part study evaluated repair strategies for biomechanical restoration, herniation risk and failure mode in torsion, bending and compression at physiological and hyper-physiological loads using a bovine injury model. Fibrin-genipin hydrogel restored some torsional stiffness, bending ROM and disc height loss, with negligible herniation risk and failure was observed histologically at the fibrin-genipin mid-substance following rigorous loading. Scaffold-based repairs partially restored biomechanics, but had high herniation risk even when stabilized with sutured membranes and failure was observed histologically at the interface between scaffold and fibrin-genipin adhesive. Fibrin-genipin was the simplest annulus fibrosus repair solution evaluated that involved an easily deliverable adhesive that filled irregularly-shaped annular defects and partially restored disc biomechanics with low herniation risk, suggesting further evaluation for disc repair may be warranted. PMID:26577987
[Update on the respiratory management of patients with chronic neuromuscular disease].
Priou, P; Trzepizur, W; Meslier, N; Gagnadoux, F
2017-12-01
Neuromuscular diseases include a wide range of conditions that may involve potentially life-threatening respiratory complications (infection, respiratory failure). For patients with neuromuscular diseases, clinical assessment of respiratory function and regular pulmonary function tests are needed to screen for nocturnal respiratory disorders, weakness of the diaphragm and potential restrictive disorders and/or chronic hypercapnic respiratory insufficiency, possibly with couch deficiency. MANAGEMENT OF NOCTURNAL RESPIRATORY DISORDERS AND CHRONIC RESPIRATORY FAILURE: Nocturnal respiratory assistance is an important phase of care for nocturnal respiratory disorders and chronic respiratory failure. This may involve continuous positive airway pressure, adaptative servo-ventilation or non-invasive ventilation with a facial or nasal mask. As needed, diurnal assistance may be proposed by mouthpiece ventilation. Should non-invasive ventilation prove insufficient, or if significant swallowing disorders or recurrent bronchial obstruction develop, or in case of prolonged intubation, tracheotomy may be required. In case of lower airway infection with ineffective cough, physical therapy, associated with air stacking, intermittent positive pressure breathing or mechanical in-exsufflation may be proposed. Care for swallowing disorders, nutritional counseling (cachexia, obesity), vaccinations and therapeutic education are integral elements of patient-centered management aiming to prevent the negative impact of infection and to manage respiratory failure of chronic neuromuscular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Conesa-Muñoz, Jesús; Gonzalez-de-Soto, Mariano; Gonzalez-de-Santos, Pablo; Ribeiro, Angela
2015-01-01
This paper describes a supervisor system for monitoring the operation of automated agricultural vehicles. The system analyses all of the information provided by the sensors and subsystems on the vehicles in real time and notifies the user when a failure or potentially dangerous situation is detected. In some situations, it is even able to execute a neutralising protocol to remedy the failure. The system is based on a distributed and multi-level architecture that divides the supervision into different subsystems, allowing for better management of the detection and repair of failures. The proposed supervision system was developed to perform well in several scenarios, such as spraying canopy treatments against insects and diseases and selective weed treatments, by either spraying herbicide or burning pests with a mechanical-thermal actuator. Results are presented for selective weed treatment by the spraying of herbicide. The system successfully supervised the task; it detected failures such as service disruptions, incorrect working speeds, incorrect implement states, and potential collisions. Moreover, the system was able to prevent collisions between vehicles by taking action to avoid intersecting trajectories. The results show that the proposed system is a highly useful tool for managing fleets of autonomous vehicles. In particular, it can be used to manage agricultural vehicles during treatment operations. PMID:25751079
Impaired face detection may explain some but not all cases of developmental prosopagnosia.
Dalrymple, Kirsten A; Duchaine, Brad
2016-05-01
Developmental prosopagnosia (DP) is defined by severe face recognition difficulties due to the failure to develop the visual mechanisms for processing faces. The two-process theory of face recognition (Morton & Johnson, 1991) implies that DP could result from a failure of an innate face detection system; this failure could prevent an individual from then tuning higher-level processes for face recognition (Johnson, 2005). Work with adults indicates that some individuals with DP have normal face detection whereas others are impaired. However, face detection has not been addressed in children with DP, even though their results may be especially informative because they have had less opportunity to develop strategies that could mask detection deficits. We tested the face detection abilities of seven children with DP. Four were impaired at face detection to some degree (i.e. abnormally slow, or failed to find faces) while the remaining three children had normal face detection. Hence, the cases with impaired detection are consistent with the two-process account suggesting that DP could result from a failure of face detection. However, the cases with normal detection implicate a higher-level origin. The dissociation between normal face detection and impaired identity perception also indicates that these abilities depend on different neurocognitive processes. © 2015 John Wiley & Sons Ltd.
Mechanics of hard films on soft substrates
NASA Astrophysics Data System (ADS)
Lu, Nanshu
2009-12-01
Flexible electronics have been developed for various applications, including paper-like electronic readers, rollable solar cells, electronic skins etc., with the merits of light weight, low cost, large area, and ruggedness. The systems may be subject to one-time or repeated large deformation during manufacturing and application. Although organic materials can be highly deformable, currently they are not able to fulfill every electronic function. Therefore flexible electronic devices are usually made as organic/inorganic hybrids, with diverse materials, complex architecture, and micro features. While the polymer substrates can recover from large deformations, thin films of electronic materials such as metals, silicon, oxides, and nitrides fracture at small strains, usually less than a few percent. Mechanics of hard films on soft substrates hence holds the key to build high-performance and highly reliable flex circuits. This thesis investigates the deformability and failure mechanisms of thin films of metallic and ceramic materials supported by soft polymeric substrates through combined experimental, theoretical, and numerical methods. When subject to tension, micron-thick metal films with stable microstructure and strong interfacial adhesion to the substrate can be stretched beyond 50% without forming cracks. They eventually rupture by a ductile transgranular fracture which involves simultaneous necking and debonding. When metal films become nanometer-thick, intergranular fracture dominates the failure mode at elongations of only a few percent. Unannealed films show unstable microstructure at room temperature when subject to mechanical loading. In this case, films also rupture at small strains but by three concurrent mechanisms: deformation-induced grain growth, strain localization at large grains, and simultaneous debonding. In contrast to metal films, ceramic films rupture by brittle mechanisms. The only way to prevent rupture of ceramic films is to reduce the strain they are subject to. Instead of using blanket films that fail at strains less than i%, we have patterned ceramic films into a lattice of periodic, isolated islands. Failure modes such as channel cracking, debonding, and wrinkling have been identified. Island behaviors are controlled by factors such as island size, thickness, and elastic mismatch with the substrate. A very soft interlayer between the islands and the underlying polyimide substrate reduces strains in the islands by orders of magnitude. Using this approach, substrates with arrays of 200 x 200 mum2 large SiNx islands were stretched beyond 20% without cracking or debonding the islands. In summary, highly stretchable thin metal films and ceramic island arrays supported by polymer substrates have been achieved, along with mechanistic understandings of their deformation and failure mechanisms.
ERIC Educational Resources Information Center
Kalahar, Kory G.
2011-01-01
Student failure is a prominent issue in many comprehensive secondary schools nationwide. Researchers studying error, reliability, and performance in organizations have developed and employed a method known as critical incident technique (CIT) for investigating failure. Adopting an action research model, this study involved gathering and analyzing…
Enhancing MPLS Protection Method with Adaptive Segment Repair
NASA Astrophysics Data System (ADS)
Chen, Chin-Ling
We propose a novel adaptive segment repair mechanism to improve traditional MPLS (Multi-Protocol Label Switching) failure recovery. The proposed mechanism protects one or more contiguous high failure probability links by dynamic setup of segment protection. Simulations demonstrate that the proposed mechanism reduces failure recovery time while also increasing network resource utilization.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... discussion of analyses of the initial submissions of data concerning mechanical fitting failures in... information. The DIMP rule also required distribution pipeline operators to report failures of mechanical... mechanical fitting failure reporting will be preliminary at this time. They will be based on a limited set of...
On Possible Arc Inception on Low Voltage Solar Array
NASA Technical Reports Server (NTRS)
Vayner, Boris
2015-01-01
Recent analysis of spacecraft failures during the period of 1990-2013 demonstrated clearly that electrostatic discharges caused more than 8 of all registered failures and anomalies, and comprised the most costly losses (25) for operating companies and agencies. The electrostatic discharges on spacecraft surfaces are the results of differential charging above some critical (threshold) voltages. The mechanisms of differential charging are well known, and various methods have been developed to prevent a generation of significant electric fields in areas of triple junctions. For example, low bus voltages in Low Earth Orbit plasma environment and slightly conducting layer over coverglass (ITO) in Geosynchronous Orbit surroundings are believed to be quite reliable measures to prevent discharges on respective surfaces. In most cases, the vulnerable elements of spacecraft (solar arrays, diode boards, etc.) go through comprehensive ground tests in vacuum chambers. However, tests articles contain the miniscule fragments of spacecraft components such as 10-30 solar cells of many thousands deployed on spacecraft in orbit. This is one reason why manufacturing defects may not be revealed in ground tests but expose themselves in arcing on array surface in space. The other reason for ineffectiveness of discharge preventive measures is aging of all materials in harsh orbital environments. The expected life time of modern spacecraft varies within the range of five-fifteen years, and thermal cycling, radiation damages, and mechanical stresses can result in surface erosion on conductive layers and microscopic cracks in coverglass sheets and adhesive films. These possible damages may cause significant increases in local electric field strengths and subsequent discharges. The primary discharges may or may not be detrimental to spacecraft operation, but they can produce the necessary conditions for sustained arcs initiation. Multiple measures were developed to prevent sustained discharges between adjacent strings, and many ground tests were performed to determine threshold parameters (voltage and current) for sustained arcs. And again, manufacturing defects and aging in space environments may result in considerable decrease of critical threshold parameters. This paper is devoted to the analysis of possible reasons behind arcing on spacecraft with low bus voltages.
On Possible Arc Inception on Low Voltage Solar Array
NASA Technical Reports Server (NTRS)
Vayner, Boris
2015-01-01
Recent analysis of spacecraft failures during the period of 1990-2013 demonstrated clearly that electrostatic discharges caused more than 8 percent of all registered failures and anomalies, and comprised the most costly losses (25 percent) for operating companies and agencies. The electrostatic discharges on spacecraft surfaces are the results of differential charging above some critical (threshold) voltages. The mechanisms of differential charging are well known, and various methods have been developed to prevent a generation of significant electric fields in areas of triple junctions. For example, low bus voltages in Low Earth Orbit plasma environment and slightly conducting layer over cover-glass (ITO) in Geosynchronous Orbit surroundings are believed to be quite reliable measures to prevent discharges on respective surfaces. In most cases, the vulnerable elements of spacecraft (solar arrays, diode boards, etc.) go through comprehensive ground tests in vacuum chambers. However, tests articles contain the miniscule fragments of spacecraft components such as 10-30 solar cells of many thousands deployed on spacecraft in orbit. This is one reason why manufacturing defects may not be revealed in ground tests but expose themselves in arcing on array surface in space. The other reason for ineffectiveness of discharge preventive measures is aging of all materials in harsh orbital environments. The expected life time of modern spacecraft varies within the range of five-fifteen years, and thermal cycling, radiation damages, and mechanical stresses can result in surface erosion on conductive layers and microscopic cracks in cover-glass sheets and adhesive films. These possible damages may cause significant increases in local electric field strengths and subsequent discharges. The primary discharges may or may not be detrimental to spacecraft operation, but they can produce the necessary conditions for sustained arcs initiation. Multiple measures were developed to prevent sustained discharges between adjacent strings, and many ground tests were performed to determine threshold parameters (voltage and current) for sustained arcs. And again, manufacturing defects and aging in space environments may result in considerable decrease of critical threshold parameters. This paper is devoted to the analysis of possible reasons behind arcing on spacecraft with low bus voltages.
Tensile strength and failure load of sutures for robotic surgery.
Abiri, Ahmad; Paydar, Omeed; Tao, Anna; LaRocca, Megan; Liu, Kang; Genovese, Bradley; Candler, Robert; Grundfest, Warren S; Dutson, Erik P
2017-08-01
Robotic surgical platforms have seen increased use among minimally invasive gastrointestinal surgeons (von Fraunhofer et al. in J Biomed Mater Res 19(5):595-600, 1985. doi: 10.1002/jbm.820190511 ). However, these systems still suffer from lack of haptic feedback, which results in exertion of excessive force, often leading to suture failures (Barbash et al. in Ann Surg 259(1):1-6, 2014. doi: 10.1097/SLA.0b013e3182a5c8b8 ). This work catalogs tensile strength and failure load among commonly used sutures in an effort to prevent robotic surgical consoles from exceeding identified thresholds. Trials were thus conducted on common sutures varying in material type, gauge size, rate of pulling force, and method of applied force. Polydioxanone, Silk, Vicryl, and Prolene, gauges 5-0 to 1-0, were pulled till failure using a commercial mechanical testing system. 2-0 and 3-0 sutures were further tested for the effect of pull rate on failure load at rates of 50, 200, and 400 mm/min. 3-0 sutures were also pulled till failure using a da Vinci robotic surgical system in unlooped, looped, and at the needle body arrangements. Generally, Vicryl and PDS sutures had the highest mechanical strength (47-179 kN/cm 2 ), while Silk had the lowest (40-106 kN/cm 2 ). Larger diameter sutures withstand higher total force, but finer gauges consistently show higher force per unit area. The difference between material types becomes increasingly significant as the diameters decrease. Comparisons of identical suture materials and gauges show 27-50% improvement in the tensile strength over data obtained in 1985 (Ballantyne in Surg Endosc Other Interv Tech 16(10):1389-1402, 2002. doi: 10.1007/s00464-001-8283-7 ). No significant differences were observed when sutures were pulled at different rates. Reduction in suture strength appeared to be strongly affected by the technique used to manipulate the suture. Availability of suture tensile strength and failure load data will help define software safety protocols for alerting a surgeon prior to suture failure during robotic surgery. Awareness of suture strength weakening with direct instrument manipulation may lead to the development of better techniques to further reduce intraoperative suture breakage.
Failure Prevention of Hydraulic System Based on Oil Contamination
NASA Astrophysics Data System (ADS)
Singh, M.; Lathkar, G. S.; Basu, S. K.
2012-07-01
Oil contamination is the major source of failure and wear of hydraulic system components. As per literature survey, approximately 70 % of hydraulic system failures are caused by oil contamination. Hence, to operate the hydraulic system reliably, the hydraulic oil should be of perfect condition. This requires a proper `Contamination Management System' which involves monitoring of various parameters like oil viscosity, oil temperature, contamination level etc. A study has been carried out on vehicle mounted hydraulically operated system used for articulation of heavy article, after making the platform levelled with outrigger cylinders. It is observed that by proper monitoring of contamination level, there is considerably increase in reliability, economy in operation and long service life. This also prevents the frequent failure of hydraulic system.
O'Connell, Timothy D; Block, Robert C; Huang, Shue P; Shearer, Gregory C
2017-02-01
Heart failure (HF) affects 5.7 million in the U.S., and despite well-established pharmacologic therapy, the 5-year mortality rate remains near 50%. Furthermore, the mortality rate for HF has not declined in years, highlighting the need for new therapeutic options. Omega-3 polyunsaturated fatty acids (ω3-PUFAs), eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), are important regulators of cardiovascular health. However, questions of efficacy and mechanism of action have made the use of ω3-PUFAs in all cardiovascular disease (CVD) controversial. Here, we review recent studies in animal models of HF indicating that ω3-PUFAs, particularly EPA, are cardioprotective, with the results indicating a threshold for efficacy. We also examine clinical studies suggesting that ω3-PUFAs improve outcomes in patients with HF. Due to the relatively small number of clinical studies of ω3-PUFAs in HF, we discuss EPA concentration-dependency on outcomes in clinical trials of CVD to gain insight into the perceived questionable efficacy of ω3-PUFAs clinically, with the results again indicating a threshold for efficacy. Ultimately, we suggest that the main failing of ω3-PUFAs in clinical trials might be a failure to reach a therapeutically effective concentration. We also examine mechanistic studies suggesting that ω3-PUFAs signal through free fatty acid receptor 4 (Ffar4), a G-protein coupled receptor (GPR) for long-chain fatty acids (FA), thereby identifying an entirely novel mechanism of action for ω3-PUFA mediated cardioprotection. Finally, based on mechanistic animal studies suggesting that EPA prevents interstitial fibrosis and diastolic dysfunction, we speculate about a potential benefit for EPA-Ffar4 signaling in heart failure preserved with ejection fraction. Copyright © 2016. Published by Elsevier Ltd.
Chu, Carissa; Ananworanich, Jintanat; Excler, Jean-Louis; Tucker, Joseph D.
2015-01-01
Abstract Clinical and basic science advances have raised considerable hope for achieving an HIV cure by accelerating research. This research is dominated primarily by issues about the nature and design of current and future clinical trials. Stakeholder engagement for HIV cure remains in its early stages. Our analysis examines timing and mechanisms of historical stakeholder engagement in other HIV research areas for HIV-uninfected individuals [vaccine development and pre-exposure prophylaxis (PrEP)], and HIV-infected individuals (treatment as prevention, prevention of mother-to-child transmission, and treatment of acute HIV infection) and articulate a plan for HIV cure stakeholder engagement. The experience from HIV vaccine development shows that early engagement of stakeholders helped manage expectations, mitigating the failure of several vaccine trials, while paving the way for subsequent trials. The relatively late engagement of HIV stakeholders in PrEP research may partly explain some of the implementation challenges. The treatment-related stakeholder engagement was strong and community-led from the onset and helped translation from research to implementation. We outline five steps to initiate and sustain stakeholder engagement in HIV cure research and conclude that stakeholder engagement represents a key investment in which stakeholders mutually agree to share knowledge, benefits, and risk of failure. Effective stakeholder engagement prevents misconceptions. As HIV cure research advances from early trials involving subjects with generally favorable prognosis to studies involving greater risk and uncertainty, success may depend on early and deliberate engagement of stakeholders. PMID:26061668
Lo, Ying-Ru; Chu, Carissa; Ananworanich, Jintanat; Excler, Jean-Louis; Tucker, Joseph D
2015-07-01
Clinical and basic science advances have raised considerable hope for achieving an HIV cure by accelerating research. This research is dominated primarily by issues about the nature and design of current and future clinical trials. Stakeholder engagement for HIV cure remains in its early stages. Our analysis examines timing and mechanisms of historical stakeholder engagement in other HIV research areas for HIV-uninfected individuals [vaccine development and pre-exposure prophylaxis (PrEP)], and HIV-infected individuals (treatment as prevention, prevention of mother-to-child transmission, and treatment of acute HIV infection) and articulate a plan for HIV cure stakeholder engagement. The experience from HIV vaccine development shows that early engagement of stakeholders helped manage expectations, mitigating the failure of several vaccine trials, while paving the way for subsequent trials. The relatively late engagement of HIV stakeholders in PrEP research may partly explain some of the implementation challenges. The treatment-related stakeholder engagement was strong and community-led from the onset and helped translation from research to implementation. We outline five steps to initiate and sustain stakeholder engagement in HIV cure research and conclude that stakeholder engagement represents a key investment in which stakeholders mutually agree to share knowledge, benefits, and risk of failure. Effective stakeholder engagement prevents misconceptions. As HIV cure research advances from early trials involving subjects with generally favorable prognosis to studies involving greater risk and uncertainty, success may depend on early and deliberate engagement of stakeholders.
Nutritional aspects in inflammatory bowel disease.
Shamir, Raanan
2009-04-01
Nutrition plays a role in inflammatory bowel disease (IBD) primarily in prevention and treatment of malnutrition and growth failure. Furthermore, in Crohn disease (CD), nutrition can induce remission, maintain remission, and prevent relapse. Malnutrition is common in IBD and the mechanisms involved include decreased food intake, malabsorption, increased nutrient loss, increased energy requirements, and drug-nutrient interactions. At the time of diagnosis, up to 85% of pediatric patients with CD and 65% of those with ulcerative colitis (UC) have weight loss. Growth failure occurs in 15% to 40% of children with IBD and is less common in UC compared with CD, both at diagnosis and during follow-up. In CD, nutritional therapy with enteral formulas induces remission at a rate comparable with that achieved with steroids. In adults with CD, limited information suggests that enteral nutrition (EN) may play a role in maintenance of remission. In children with CD colitis, one study suggested that children without colitis respond better to EN than children with colitis, and another study found no such difference but reported a trend toward earlier relapse in those with isolated colonic involvement. Finally, nutrition may play a role in IBD via the possible protective effect of breastfeeding against UC and CD. In summary, although only CD may benefit from nutrition as primary therapy for remission induction and possibly maintenance of remission, nutrition plays an important role in the prevention and treatment of malnutrition in IBD, and may have a protective role, via the effect of breast-feeding on disease occurrence.
Stine, Jonathan G.; Lewis, James H.
2016-01-01
While the pace of discovery of new agents, mechanisms and risk factors involved in drug-induced liver injury (DILI) remains brisk, advances in the treatment of acute DILI seems slow by comparison. In general, the key to treating suspected DILI is to stop using the drug prior to developing irreversible liver failure. However, predicting when to stop is an inexact science, and commonly used ALT monitoring is an ineffective strategy outside of clinical trials. The only specific antidote for acute DILI remains N-acetylcysteine (NAC) for acetaminophen poisoning, although NAC is proving to be beneficial in some cases of non-acetaminophen DILI in adults. Corticosteroids can be effective for DILI associated with autoimmune or systemic hypersensitivity features. Ursodeoxycholic acid, silymarin and glycyrrhizin have been used to treat DILI for decades, but success remains anecdotal. Bile acid washout regimens using cholestyramine appear to be more evidenced based, in particular for lefluonomide toxicity. For drug-induced acute liver failure, the use of liver support systems is still investigational in the United States and emergency liver transplant remains limited by its availability. Primary prevention appears to be the key to avoiding DILI and the need for acute treatment. Pharmacogenomics, including HLA genotyping and the discovery of specific DILI biomarkers offers significant promise for the future. This article describes and summarizes the numerous and diverse treatment and prevention modalities that are currently available to manage DILI. PMID:26633044
Register of specialized sources for information on mechanics of structural failure
NASA Technical Reports Server (NTRS)
Carpenter, J. L., Jr.; Denny, F. J.
1973-01-01
Specialized information sources that generate information relative to six problem areas in aerospace mechanics of structural failure are identified. Selection for inclusion was based upon information obtained from the individual knowledge and professional contacts of Martin Marietta Aerospace staff members and the information uncovered by the staff of technical reviewers. Activities listed perform basic or applied research related to the mechanics of structural failure and publish the results of such research. The purpose of the register is to present, in easy reference form, original sources for dependable information regarding failure modes and mechanisms of aerospace structures.
NASA Astrophysics Data System (ADS)
Zhu, Qi-Zhi
2017-02-01
A proper criterion describing when material fails is essential for deep understanding and constitutive modeling of rock damage and failure by microcracking. Physically, such a criterion should be the global effect of local mechanical response and microstructure evolution inside the material. This paper aims at deriving a new mechanisms-based failure criterion for brittle rocks, based on micromechanical unilateral damage-friction coupling analyses rather than on the basic results from the classical linear elastic fracture mechanics. The failure functions respectively describing three failure modes (purely tensile mode, tensile-shear mode as well as compressive-shear mode) are achieved in a unified upscaling framework and illustrated in the Mohr plane and also in the plane of principal stresses. The strength envelope is proved to be continuous and smooth with a compressive to tensile strength ratio dependent on material properties. Comparisons with experimental data are finally carried out. By this work, we also provide a theoretical evidence on the hybrid failure and the smooth transition from tensile failure to compressive-shear failure.
Yau, James M; Alexander, John H; Hafley, Gail; Mahaffey, Kenneth W; Mack, Michael J; Kouchoukos, Nicholas; Goyal, Abhinav; Peterson, Eric D; Gibson, C Michael; Califf, Robert M; Harrington, Robert A; Ferguson, T Bruce
2008-09-01
Myocardial infarction (MI) after coronary artery bypass grafting (CABG) is associated with significant morbidity and mortality. Frequency, management, mechanisms, and angiographic and clinical outcomes associated with perioperative MI remain poorly understood. PREVENT IV was a multicenter, randomized, placebo-controlled trial of edifoligide in 3,014 patients undergoing CABG. Angiographic and 2-year clinical follow-up were complete for 1,920 and 2,956 patients, respectively. Perioperative MI was defined as creatinine kinase-MB increase >or=10 times the upper limit of normal or >or=5 times the upper limit of normal with new 30-ms Q waves within 24 hours of surgery. Baseline characteristics, in-hospital management, and angiographic and clinical outcomes of patients with and without perioperative MI were compared. Perioperative MI occurred in 294 patients (9.8%). Patients with perioperative MI had longer surgery (250 vs 230 minutes; p <0.001), more on-pump surgery (83% vs 78%; p = 0.048), and worse target-artery quality (p <0.001). Patients with perioperative MI more frequently underwent angiography within 30 days of enrollment (1.7% vs 0.6%; p = 0.021). One-year angiographic vein graft failure occurred in 62.4% of patients with and 43.8% of patients without perioperative MI (p <0.001). Two-year composite clinical outcome (death, MI, or revascularization) was worse in patients with perioperative MI before (19.4% vs 15.2%; p = 0.039) and after (hazard ratio 1.33, 95% confidence interval 1.00 to 1.76, p = 0.046) adjusting for differences in significant predictors. In conclusion, perioperative MI was relatively common, was associated with worse outcomes, and mechanisms other than vein graft failure accounted for a substantial proportion of these MIs. Further research is needed into the prevention and treatment of perioperative MI in patients undergoing CABG.
Lygate, Craig A.; Bohl, Steffen; ten Hove, Michiel; Faller, Kiterie M.E.; Ostrowski, Philip J.; Zervou, Sevasti; Medway, Debra J.; Aksentijevic, Dunja; Sebag-Montefiore, Liam; Wallis, Julie; Clarke, Kieran; Watkins, Hugh; Schneider, Jürgen E.; Neubauer, Stefan
2012-01-01
Aims Increasing energy storage capacity by elevating creatine and phosphocreatine (PCr) levels to increase ATP availability is an attractive concept for protecting against ischaemia and heart failure. However, testing this hypothesis has not been possible since oral creatine supplementation is ineffectual at elevating myocardial creatine levels. We therefore used mice overexpressing creatine transporter in the heart (CrT-OE) to test for the first time whether elevated creatine is beneficial in clinically relevant disease models of heart failure and ischaemia/reperfusion (I/R) injury. Methods and results CrT-OE mice were selected for left ventricular (LV) creatine 20–100% above wild-type values and subjected to acute and chronic coronary artery ligation. Increasing myocardial creatine up to 100% was not detrimental even in ageing CrT-OE. In chronic heart failure, creatine elevation was neither beneficial nor detrimental, with no effect on survival, LV remodelling or dysfunction. However, CrT-OE hearts were protected against I/R injury in vivo in a dose-dependent manner (average 27% less myocardial necrosis) and exhibited greatly improved functional recovery following ex vivo I/R (59% of baseline vs. 29%). Mechanisms contributing to ischaemic protection in CrT-OE hearts include elevated PCr and glycogen levels and improved energy reserve. Furthermore, creatine loading in HL-1 cells did not alter antioxidant defences, but delayed mitochondrial permeability transition pore opening in response to oxidative stress, suggesting an additional mechanism to prevent reperfusion injury. Conclusion Elevation of myocardial creatine by 20–100% reduced myocardial stunning and I/R injury via pleiotropic mechanisms, suggesting CrT activation as a novel, potentially translatable target for cardiac protection from ischaemia. PMID:22915766
Effects of surface preparation on the long-term durability of adhesively bonded composite joints
NASA Astrophysics Data System (ADS)
Bardis, Jason Dante
The long-term durability of adhesively bonded composite joints is critical to modern aircraft structures, which are increasingly adopting bonding as an alternative option to mechanical fastening. The effects of the surface preparation of the adherends are critical, affecting initial strength, long-term durability, fracture toughness, and failure modes of bonded joints. In this study, several potential factors are evaluated, with focus on the following: (1) Effects of possible chemical contamination from release fabrics, release films, and peel plies during adherend cure. (2) Chemical and mechanical effects of abrasion on the fracture toughness and failure mode. (3) Characterization of paste and film adhesives. There are several standard test methods used to evaluate specimen fracture, but the majority concentrate on bonded metals and interlaminar composite fracture. Testing concentrated on mode I tests; a custom double cantilever beam specimen was devised and utilized, and two forms of a wedge crack test (traveling and static) were also used. Additionally, single lap shear tests were run to contrast the mode I tests. Non-destructive testing included X-ray photography of crack fronts, energy dispersive spectroscopy and X-ray photoelectron spectroscopy surface chemistry analyses, and scanning electron microscope imaging of prepared surfaces. All mode I test methods tended to be in agreement in the ranking of different surface preparation methods. Test results revealed that release agents deposited on adherend surfaces during their cure cycle prevented proper adhesion. While mechanical abrasion did improve their fracture toughness and lower their contamination greatly, the test values did not reach the levels of samples that were not contaminated before bonding, and the interfacial modes of failure did not always change to desirable modes.
Liang, Li-rong; Zhang, Zhu; Wang, Hong; Xu, Zhen-yang; Qian, Xiao-sen; Zhang, Zuo-qing; Chen, Jin; Zhang, Feng-zhen; Yang, Yuan-hua
2013-08-13
To explore the proportion and prevention status of venous thromboembolism (VTE) among hospitalized patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD) in Beijing. Based on a multi-center retrospective study, a total of 636 hospitalized AECOPD patients from 17 class 2/3 hospitals in Beijing were examined from September 1, 2011 to March 31, 2012. They fulfilled one of the following criteria: respiratory failure type II, on invasive or non-invasive mechanical ventilation, hospitalization for pulmonary infection, bedridden duration ≥ 3 days and congestive heart failure. All investigators received standardized training and used a standardized questionnaire to collect data on VTE risk factors, the diagnosis of VTE and the utilization of VTE prophylaxis. According to Caprini score, they were categorized into 3 groups of lower risk (Caprini score ≤ 3), moderate risk (Caprini score 4-6) and high risk ( ≥ 7) to compare the intergroup differences in the VTE proportion and the utilization of VTE prophylaxis. A total of 636 patients were assessed. There were 416 males and 220 females with a mean (SD) age of 74.9 ± 9.3 years. Among them, 133 patients received lower extremity venous ultrasonic examination and 92 were diagnosed with deep venous thrombosis (DVT) including 2 patients with pulmonary thromboembolism (PTE). Thus the overall incidence of VTE was 14.5% (92/636) and increased with age (Ptrend = 0.044). The proportion of VTE in asymptomatic patients was higher in those symptomatic ones (21.1% vs 8.0%, P = 0.000). And it was the highest in high risk group, followed by lower risk and moderate risk groups at 17.9% (14/78), 16.0% (26/163) and 13.2% (52/395) respectively, There was no statistical significance (P = 0.450 for group difference, Ptrend = 0.946). Among 544 patients without VTE, only 19.1% (104/544) employed the pharmacologic and/or mechanical methods for preventing VTE. The prevention proportion gradually increased with rising Caprini score, i.e. 17.5%, 18.4% and 26.6% for lower, moderate and higher risk group respectively. There was no statistical significance (P = 0.266 for group difference, Ptrend = 0.201). The proportion of VTE is relatively higher. However, the preventive methods are significantly underutilized among hospitalized AECOPD patients in Beijing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, M.G.; Kohles, S.S.; Stevens, T.L.
1996-12-31
Duality of failure mechanisms (slow crack growth from pre-existing defects versus cumulative creep damage) is examined in a silicon nitride advanced ceramic recently tested at elevated-temperatures. Static (constant stress over time), dynamic (monotonically-increasing stress over time), and cyclic (fluctuating stress over time) fatigue behaviors were evaluated in tension in ambient air at temperatures of 1150, 1260, and 1370{degrees}C for a hot-isostatically pressed monolithic {beta}-silicon nitride. At 1150{degrees}C, all three types of fatigue results showed the similar failure mechanism of slow crack growth (SCG). At 1260 and 1370{degrees}C the failure mechanism was more complex. Failure under static fatigue was dominated bymore » the accumulation of creep damage via diffusion-controlled cavities. In dynamic fatigue, failure occurred by SCG at high stress rates (>10{sup {minus}2}MPa/s) and by creep damage at low stress rates ({le}10{sup {minus}2} MPa/s). For cyclic fatigue, such rate effects influenced the stress rupture results in which times to failure were greater for dynamic and cyclic fatigue than for static fatigue. Elucidation of failure mechanisms is necessary for accurate prediction of long-term survivability and reliability of structural ceramics.« less
How cracks are hot and cool: a burning issue for this paper
NASA Astrophysics Data System (ADS)
Toussaint, Renaud; Santucci, Stéphane; Lengliné, Olivier; Maloy, Knut Jorgen; Vincent-Dospital, Tom; Naert-Giuillot, Muriel
2017-04-01
Material failure is accompanied by important heat exchange, with extremely high temperature - thousands of degrees - reached at crack tips. Such temperature may subsequently alter the mechanical properties of stressed solids, and finally facilitate their rupture. Thermal runaway weakening processes could indeed explain stick-slip motions and even be responsible for deep earthquakes. Therefore, to better understand and eventually prevent catastrophic rupture events, it appears crucial to establish an accurate energy budget of fracture propagation from a clear measure of the various energy dissipation sources. In this work, combining analytical calculations and numerical simulations, we directly relate the temperature field around a moving crack tip to the part α of mechanical energy converted into heat. Monitoring the slow crack growth in paper sheets with an infrared camera, we measure a significant fraction α = 12±4%. Besides, we show that (self-generated) heat accumulation could weaken our samples with microfibers combustion, and lead to a fast crack/dynamic failure/ regime. Reference: Toussaint, R., Lengline, O., Santucci, S., Vincent-Dospital, T., Naert-Guillot, M. and Maloy, K.J., How cracks are hot and cool: a burning issue for paper (2016), Soft Matter (12), 5563-5571, DOI: 10.1039/C6SM00615A
NASA Astrophysics Data System (ADS)
Abdel-Aal, H. A.; Mansori, M. El
2012-12-01
Cutting tools are subject to extreme thermal and mechanical loads during operation. The state of loading is intensified in dry cutting environment especially when cutting the so called hard-to-cut-materials. Although, the effect of mechanical loads on tool failure have been extensively studied, detailed studies on the effect of thermal dissipation on the deterioration of the cutting tool are rather scarce. In this paper we study failure of coated carbide tools due to thermal loading. The study emphasizes the role assumed by the thermo-physical properties of the tool material in enhancing or preventing mass attrition of the cutting elements within the tool. It is shown that within a comprehensive view of the nature of conduction in the tool zone, thermal conduction is not solely affected by temperature. Rather it is a function of the so called thermodynamic forces. These are the stress, the strain, strain rate, rate of temperature rise, and the temperature gradient. Although that within such consideration description of thermal conduction is non-linear, it is beneficial to employ such a form because it facilitates a full mechanistic understanding of thermal activation of tool wear.
Failure mechanisms and closed reduction of a constrained tripolar acetabular liner.
Robertson, William J; Mattern, Christopher J; Hur, John; Su, Edwin P; Pellicci, Paul M
2009-02-01
Unlike traditional bipolar constrained liners, the Osteonics Omnifit constrained acetabular insert is a tripolar device, consisting of an inner bipolar bearing articulating within an outer, true liner. Every reported failure of the Omnifit tripolar implant has been by failure at the shell-bone interface (Type I failure), failure at the shell-liner interface (Type II failure), or failure of the locking mechanism resulting in dislocation of the bipolar-liner interface (Type III failure). In this report we present two cases of failure of the Omnifit tripolar at the bipolar-femoral head interface. To our knowledge, these are the first reported cases of failure at the bipolar-femoral head interface (Type IV failure). In addition, we described the first successful closed reduction of a Type IV failure.
Davies, Shelley L; Ferrer, Elisa; Moral, Maria Angels
2006-06-01
Chronicles in Drug Discovery features special interest reports on advances in drug discovery. This month we highlight new options to prevent oral mucositis, a treatment-limiting adverse effect of chemotherapy. Studies are currently focusing on mechanism-based therapies to prevent or repair DNA damage to epithelial and submucosal cells and the cascade or events that follow to cause tissue damage or analgesics to ease the associated oral cavity pain. Therapeutic limitations also exist for the use of the highly effective antibiotic gentamicin, as it evokes acute renal failure. Mechanistic investigations have shed some light on potential targets: the kallikreins, peroxynitrite-related pathways, superoxide production and the accumulation of aminoglycosides. New antibiotic strategies for trachoma, the leading cause of preventable blindness, are also explored along with studies to aid the development of vaccine candidates. Finally, we discuss the utility of allosteric-potentiating ligands to modulate nicotinic acetylcholine receptors, mimicking the reward/addictive effects of nicotine, as potential strategies for smoking cessation. (c) 2006 Prous Science. All rights reserved.
Acute kidney injury by radiographic contrast media: pathogenesis and prevention.
Andreucci, Michele; Faga, Teresa; Pisani, Antonio; Sabbatini, Massimo; Michael, Ashour
2014-01-01
It is well known that iodinated radiographic contrast media may cause kidney dysfunction, particularly in patients with preexisting renal impairment associated with diabetes. This dysfunction, when severe, will cause acute renal failure (ARF). We may define contrast-induced Acute Kidney Injury (AKI) as ARF occurring within 24-72 hrs after the intravascular injection of iodinated radiographic contrast media that cannot be attributed to other causes. The mechanisms underlying contrast media nephrotoxicity have not been fully elucidated and may be due to several factors, including renal ischaemia, particularly in the renal medulla, the formation of reactive oxygen species (ROS), reduction of nitric oxide (NO) production, and tubular epithelial and vascular endothelial injury. However, contrast-induced AKI can be prevented, but in order to do so, we need to know the risk factors. We have reviewed the risk factors for contrast-induced AKI and measures for its prevention, providing a long list of references enabling readers to deeply evaluate them both.
Acute Kidney Injury by Radiographic Contrast Media: Pathogenesis and Prevention
Faga, Teresa; Pisani, Antonio; Michael, Ashour
2014-01-01
It is well known that iodinated radiographic contrast media may cause kidney dysfunction, particularly in patients with preexisting renal impairment associated with diabetes. This dysfunction, when severe, will cause acute renal failure (ARF). We may define contrast-induced Acute Kidney Injury (AKI) as ARF occurring within 24–72 hrs after the intravascular injection of iodinated radiographic contrast media that cannot be attributed to other causes. The mechanisms underlying contrast media nephrotoxicity have not been fully elucidated and may be due to several factors, including renal ischaemia, particularly in the renal medulla, the formation of reactive oxygen species (ROS), reduction of nitric oxide (NO) production, and tubular epithelial and vascular endothelial injury. However, contrast-induced AKI can be prevented, but in order to do so, we need to know the risk factors. We have reviewed the risk factors for contrast-induced AKI and measures for its prevention, providing a long list of references enabling readers to deeply evaluate them both. PMID:25197639
HBV-Associated Acute Liver Failure After Immunosuppression and Risk of Death.
Karvellas, Constantine J; Cardoso, Filipe S; Gottfried, Michelle; Reddy, K Rajender; Hanje, A James; Ganger, Daniel; Lee, William M
2017-01-01
Acute liver failure (ALF) caused by hepatitis B virus (HBV) infection can occur after immunosuppressive treatment and be fatal, although it might be preventable. We aimed to characterize the causes, clinical course, and short-term outcomes of HBV-associated ALF after immune-suppressive therapy, compared with patients with HBV-associated ALF without immunosuppression (control subjects). We performed a retrospective multicenter study of 156 consecutive patients diagnosed with HBV-associated ALF (22 with a solid or blood malignancy) enrolled in the Acute Liver Failure Study Group registry from January 1998 through April 2015. We collected data on results of serologic and hepatic biochemistry analyses, grade of hepatic encephalopathy, Model for End-Stage Liver Disease score, and King's College criteria. We also collected data on clinical features, medical therapies, and complications in the first 7 days following study enrollment. Logistic regression was used to identify factors associated with transplant-free survival at 21 days in HBV-associated ALF (the primary outcome). Among patients with HBV-associated ALF, 28 cases (18%) occurred after immunosuppressive therapy (15 patients received systemic corticosteroids and 21 received chemotherapy); and 128 cases did not (control subjects, 82%). Significantly greater proportions of patients with HBV-associated ALF after immunosuppression were nonwhite persons, and had anemia or thrombocytopenia than controls (P < .02 for all). The serologic profile of HBV infection, severity of liver failure (based on MELD score), and complications (hepatic encephalopathy or need for mechanical ventilation, vasopressors, or renal replacement therapy) were similar between the groups (P > .17 for all). Factors associated with 21 day transplant-free survival were increased MELD score (odds ratio ∼OR, 0.894 (95% confidence interval 0.842-0.949 per increment), requirement for mechanical ventilation (OR 0.111(0.041-0.300), and immunosuppressive therapy (OR 0.274(0.082-0.923)). Within a cohort study of patients with HBV-associated ALF, 18% had received immunosuppressive therapy. Significantly smaller proportions of patients with HBV-associated ALF after immunosuppression survive beyond 21 days than patients with HBV-associated ALF who did not receive immunosuppression. Patients undergoing chemotherapy should be screened for HBV infection and given appropriate antiviral therapies to reduce preventable mortality. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Protective Effects of ω-3 PUFA in Anthracycline-Induced Cardiotoxicity: A Critical Review.
Serini, Simona; Ottes Vasconcelos, Renata; Nascimento Gomes, Renata; Calviello, Gabriella
2017-12-12
It has been demonstrated that ω-3 polyunsaturated fatty acids (ω-3 PUFA) may exert a beneficial role as adjuvants in the prevention and treatment of many disorders, including cardiovascular diseases and cancer. Particularly, several in vitro and in vivo preclinical studies have shown the antitumor activity of ω-3 PUFA in different kinds of cancers, and several human studies have shown that ω-3 PUFA are able to decrease the risk of a series of cardiovascular diseases. Several mechanisms have been proposed to explain their pleiotropic beneficial effects. ω-3 PUFA have also been shown to prevent harmful side-effects (including cardiotoxicity and heart failure) induced by conventional and innovative anti-cancer drugs in both animals and patients. The available literature regarding the possible protective effects of ω-3 PUFA against anthracycline-induced cardiotoxicity, as well as the mechanisms involved, will be critically discussed herein. The study will analyze the critical role of different levels of ω-3 PUFA intake in determining the results of the combinatory studies with anthracyclines. Suggestions for future research will also be considered.
Transition-state theory predicts clogging at the microscale
NASA Astrophysics Data System (ADS)
Laar, T. Van De; Klooster, S. Ten; Schroën, K.; Sprakel, J.
2016-06-01
Clogging is one of the main failure mechanisms encountered in industrial processes such as membrane filtration. Our understanding of the factors that govern the build-up of fouling layers and the emergence of clogs is largely incomplete, so that prevention of clogging remains an immense and costly challenge. In this paper we use a microfluidic model combined with quantitative real-time imaging to explore the influence of pore geometry and particle interactions on suspension clogging in constrictions, two crucial factors which remain relatively unexplored. We find a distinct dependence of the clogging rate on the entrance angle to a membrane pore which we explain quantitatively by deriving a model, based on transition-state theory, which describes the effect of viscous forces on the rate with which particles accumulate at the channel walls. With the same model we can also predict the effect of the particle interaction potential on the clogging rate. In both cases we find excellent agreement between our experimental data and theory. A better understanding of these clogging mechanisms and the influence of design parameters could form a stepping stone to delay or prevent clogging by rational membrane design.
Viral interference with DNA repair by targeting of the single-stranded DNA binding protein RPA.
Banerjee, Pubali; DeJesus, Rowena; Gjoerup, Ole; Schaffhausen, Brian S
2013-10-01
Correct repair of damaged DNA is critical for genomic integrity. Deficiencies in DNA repair are linked with human cancer. Here we report a novel mechanism by which a virus manipulates DNA damage responses. Infection with murine polyomavirus sensitizes cells to DNA damage by UV and etoposide. Polyomavirus large T antigen (LT) alone is sufficient to sensitize cells 100 fold to UV and other kinds of DNA damage. This results in activated stress responses and apoptosis. Genetic analysis shows that LT sensitizes via the binding of its origin-binding domain (OBD) to the single-stranded DNA binding protein replication protein A (RPA). Overexpression of RPA protects cells expressing OBD from damage, and knockdown of RPA mimics the LT phenotype. LT prevents recruitment of RPA to nuclear foci after DNA damage. This leads to failure to recruit repair proteins such as Rad51 or Rad9, explaining why LT prevents repair of double strand DNA breaks by homologous recombination. A targeted intervention directed at RPA based on this viral mechanism could be useful in circumventing the resistance of cancer cells to therapy.
Lee, Lydia C; Charlton, Timothy P; Thordarson, David B
2013-12-01
A floating toe deformity occurs in many patients who undergo Weil osteotomies. It is likely caused by the failure of the windlass mechanism in shortening the metatarsal. For patients who require a proximal interphalangeal (PIP) joint arthroplasty or fusion in addition to a Weil osteotomy, the transfer of the flexor digitorum brevis (FDB) tendon to the PIP joint might restore the windlass mechanism and decrease the incidence of floating toes. Fourteen cadaveric foot specimens were examined to determine the effects of changing metatarsal length as well as tensioning the FDB tendon on the angle of the metatarsophalangeal (MTP) joint as a measure of a floating toe. Shortening and lengthening the second metatarsal resulted in a significant change in MTP angle (P = .03 and .02, respectively), though there was no clear relationship found between the amount of change in metatarsal length and the change in MTP angle. Transferring the FDB to a PIP arthroplasty site plantarflexed the MTP joint and corrected floating toes; the change in angle was significant compared with the control and shortening groups (P = .0001 and .002, respectively). This study supports the theory that change in length of the metatarsal, possibly via the windlass mechanism, plays a role in the pathophysiology of the floating toe deformity. Tensioning and transferring the FDB tendon into the PIP joint helped prevent the floating toe deformity in this cadaveric model. Continued research in this subject will help to refine methods of prevention and correction of the floating toe deformity.
Development and application of biomimetic electrospun nanofibers in total joint replacement
NASA Astrophysics Data System (ADS)
Song, Wei
Failure of osseointegration (direct anchorage of an implant by bone formation at the bone-implant surface) and implant infection (such as that caused by Staphylococcus aureus, S. aureus) are the two main causes of implant failure and loosening. There is a critical need for orthopedic implants that promote rapid osseointegration and prevent bacterial colonization, particularly when placed in bone compromised by disease or physiology of the patients. A better understanding of the key factors that influence cell fate decisions at the bone-implant interface is required. Our study is to develop a class of "bone-like" nanofibers (NFs) that promote osseointegration while preventing bacterial colonization and subsequent infections. This research goal is supported by our preliminary data on the preparation of coaxial electrospun NFs composed of polycaprolactone (PCL) and polyvinyl alcohol (PVA) polymers arranged in a core-sheath shape. The PCL/PVA NFs are biocompatible and biodegradable with appropriate fiber diameter, pore size and mechanical strength, leading to enhanced cell adhesion, proliferation and differentiation of osteoblast precursor cells. The objective is to develop functionalized "bone-like" PCL/PVA NFs matrix embedded with antibiotics (doxycycline (Doxy), bactericidal and anti-osteoclastic) on prosthesis surface. Through a rat tibia implantation model, the Doxy incorporated coaxial NFs has demonstrated excellent in promoting osseointegration and bacteria inhibitory efficacy. NFs coatings significantly enhanced the bonding between implant and bone remodeling within 8 weeks. The SA-induced osteomyelitis was prevented by the sustained release of Doxy from NFs. The capability of embedding numerous bio-components including proteins, growth factors, drugs, etc. enables NFs an effective solution to overcome the current challenged issue in Total joint replacement. In summary, we proposed PCL/PVA electrospun nanofibers as promising biomaterials that can be applied on joint replacement prosthesis to improve osseointegration and prevent osteomyelitis.
Myers, T J; Kytömaa, H K; Smith, T R
2007-04-11
Fiberglass reinforced plastic (FRP) composite materials are often used to construct tanks, piping, scrubbers, beams, grating, and other components for use in corrosive environments. While FRP typically offers superior and cost effective corrosion resistance relative to other construction materials, the glass fibers traditionally used to provide the structural strength of the FRP can be susceptible to attack by the corrosive environment. The structural integrity of traditional FRP components in corrosive environments is usually dependent on the integrity of a corrosion-resistant barrier, such as a resin-rich layer containing corrosion resistant glass fibers. Without adequate protection, FRP components can fail under loads well below their design by an environmental stress-corrosion cracking (ESCC) mechanism when simultaneously exposed to mechanical stress and a corrosive chemical environment. Failure of these components can result in significant releases of hazardous substances into plants and the environment. In this paper, we present two case studies where fiberglass components failed due to ESCC at small chemical manufacturing facilities. As is often typical, the small chemical manufacturing facilities relied largely on FRP component suppliers to determine materials appropriate for the specific process environment and to repair damaged in-service components. We discuss the lessons learned from these incidents and precautions companies should take when interfacing with suppliers and other parties during the specification, design, construction, and repair of FRP components in order to prevent similar failures and chemical releases from occurring in the future.
Fiber-based modeling of in situ ankle ligaments with consideration of progressive failure.
Nie, Bingbing; Forman, Jason L; Panzer, Matthew B; Mait, Alexander R; Donlon, John-Paul; Kent, Richard W
2017-08-16
Ligament sprains account for a majority of injuries to the foot and ankle complex among athletic populations. The infeasibility of measuring the in situ response and load paths of individual ligaments has precluded a complete characterization of their mechanical behavior via experiment. In the present study a fiber-based modeling approach of in situ ankle ligaments was developed and validated for determining the heterogeneous force-elongation characteristics and the consequent injury patterns. Nine major ankle ligaments were modeled as bundles of discrete elements, corresponding functionally to the structure of collagen fibers. To incorporate the progressive nature of ligamentous injury, the limit strain at the occurrence of fiber failure was described by a distribution function ranging from 12% to 18% along the width of the insertion site. The model was validated by comparing the structural kinetic and kinematic response obtained experimentally and computationally under well-controlled foot rotations. The simulation results replicated the 6 degree-of-freedom bony motion and ligamentous injuries and, by implication, the in situ deformations of the ligaments. Gross stiffness of the whole ligament derived from the fibers was comparable to existing experimental data. The present modeling approach provides a biomechanically realistic, interpretable and computationally efficient way to characterize the in situ ligament slack, sequential and heterogeneous uncrimping of collagen fascicles and failure propagation as the external load is applied. Applications of this model include functional ankle joint mechanics, injury prevention and countermeasure design for athletes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hoefer, Judith; Ulmer, Hanno; Kilo, Juliane; Margreiter, Raimund; Grimm, Michael; Mair, Peter; Ruttmann, Elfriede
2017-06-01
There are few data on the role of liver dysfunction in patients with end-stage heart failure supported by mechanical circulatory support. The aim of our study was to investigate predictors for acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support. A consecutive 164 patients with heart failure with New York Heart Association class IV undergoing mechanical circulatory support were investigated for acute liver failure using the King's College criteria. Clinical characteristics of heart failure together with hemodynamic and laboratory values were analyzed by logistic regression. A total of 45 patients (27.4%) with heart failure developed subsequent acute liver failure with a hospital mortality of 88.9%. Duration of heart failure, cause, cardiopulmonary resuscitation, use of vasopressors, central venous pressure, pulmonary capillary wedge pressure, pulmonary pulsatility index, cardiac index, and transaminases were not significantly associated with acute liver failure. Repeated decompensation, atrial fibrillation (P < .001) and the use of inotropes (P = .007), mean arterial (P = .005) and pulmonary pressures (P = .042), cholinesterase, international normalized ratio, bilirubin, lactate, and pH (P < .001) were predictive of acute liver failure in univariate analysis only. In multivariable analysis, decreased antithrombin III was the strongest single measurement indicating acute liver failure (relative risk per %, 0.84; 95% confidence interval, 0.77-0.93; P = .001) and remained an independent predictor when adjustment for the Model for End-Stage Liver Disease score was performed (relative risk per %, 0.89; 95% confidence interval, 0.80-0.99; P = .031). Antithrombin III less than 59.5% was identified as a cutoff value to predict acute liver failure with a corresponding sensitivity of 81% and specificity of 87%. In addition to the Model for End-Stage Liver Disease score, decreased antithrombin III activity tends to be superior in predicting acute liver failure compared with traditionally thought predictors. Antithrombin III measurement may help to identify patients more precisely who are developing acute liver failure during mechanical circulatory support. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
2013-01-01
REPORT Friction Stir Weld Failure Mechanisms in Aluminum -Armor Structures Under Ballistic Impact Loading Conditions 14. ABSTRACT 16. SECURITY...Stir Weld Failure Mechanisms in Aluminum -Armor Structures Under Ballistic Impact Loading Conditions M. Grujicic, B. Pandurangan, A. Arakere, C-F. Yen...K.O. Pedersen, Fracture Mechanisms of Aluminum Alloy AA7075-T651 Under Various Loading Conditions , Int. J. Impact Eng., 2010, 37, p 537–551 24. T
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Song-Hua; Chang, James Y. H.; Boring,Ronald L.
2010-03-01
The Office of Nuclear Regulatory Research (RES) at the US Nuclear Regulatory Commission (USNRC) is sponsoring work in response to a Staff Requirements Memorandum (SRM) directing an effort to establish a single human reliability analysis (HRA) method for the agency or guidance for the use of multiple methods. As part of this effort an attempt to develop a comprehensive HRA qualitative approach is being pursued. This paper presents a draft of the method's middle layer, a part of the qualitative analysis phase that links failure mechanisms to performance shaping factors. Starting with a Crew Response Tree (CRT) that has identifiedmore » human failure events, analysts identify potential failure mechanisms using the mid-layer model. The mid-layer model presented in this paper traces the identification of the failure mechanisms using the Information-Diagnosis/Decision-Action (IDA) model and cognitive models from the psychological literature. Each failure mechanism is grouped according to a phase of IDA. Under each phase of IDA, the cognitive models help identify the relevant performance shaping factors for the failure mechanism. The use of IDA and cognitive models can be traced through fault trees, which provide a detailed complement to the CRT.« less
Failure mechanisms of fibrin-based surgical tissue adhesives
NASA Astrophysics Data System (ADS)
Sierra, David Hugh
A series of studies was performed to investigate the potential impact of heterogeneity in the matrix of multiple-component fibrin-based tissue adhesives upon their mechanical and biomechanical properties both in vivo and in vitro. Investigations into the failure mechanisms by stereological techniques demonstrated that heterogeneity could be measured quantitatively and that the variation in heterogeneity could be altered both by the means of component mixing and delivery and by the formulation of the sealant. Ex vivo tensile adhesive strength was found to be inversely proportional to the amount of heterogeneity. In contrast, in vivo tensile wound-closure strength was found to be relatively unaffected by the degree of heterogeneity, while in vivo parenchymal organ hemostasis in rabbits was found to be affected: greater heterogeneity appeared to correlate with an increase in hemostasis time and amount of sealant necessary to effect hemostasis. Tensile testing of the bulk sealant showed that mechanical parameters were proportional to fibrin concentration and that the physical characteristics of the failure supported a ductile mechanism. Strain hardening as a function of percentage of strain, and strain rate was observed for both concentrations, and syneresis was observed at low strain rates for the lower fibrin concentration. Blister testing demonstrated that burst pressure and failure energy were proportional to fibrin concentration and decreased with increasing flow rate. Higher fibrin concentration demonstrated predominately compact morphology debonds with cohesive failure loci, demonstrating shear or viscous failure in a viscoelastic rubbery adhesive. The lower fibrin concentration sealant exhibited predominately fractal morphology debonds with cohesive failure loci, supporting an elastoviscous material condition. The failure mechanism for these was hypothesized and shown to be flow-induced ductile fracture. Based on these findings, the failure mechanism was stochastic in nature because the mean failure energy and burst pressure values were not predictive of locus and morphology. Instead, flow rate and fibrin concentration showed the most predictive value, with the outcome best described as a probability distribution rather than a specific deterministic outcome.
Timing and Targeting of Treatment in Left Ventricular Hypertrophy.
Nam, Deokhwa; Reineke, Erin L
2017-01-01
In most clinical cases, left ventricular hypertrophy (LVH) occurs over time from persistent cardiac stress. At the molecular level, this results in both transient and long-term changes to metabolic, sarcomeric, ion handling, and stress signaling pathways. Although this is initially an adaptive change, the mechanisms underlying LVH eventually lead to maladaptive changes including fibrosis, decreased cardiac function, and failure. Understanding the regulators of long-term changes, which are largely driven by transcriptional remodeling, is a crucial step in identifying novel therapeutic targets for preventing the downstream negative effects of LVH and treatments that could reverse or prevent it. The development of effective therapeutics, however, will require a critical understanding of what to target, how to modify important pathways, and how to identify the stage of pathology in which a specific treatment should be used.
Failure criterion for materials with spatially correlated mechanical properties
NASA Astrophysics Data System (ADS)
Faillettaz, J.; Or, D.
2015-03-01
The role of spatially correlated mechanical elements in the failure behavior of heterogeneous materials represented by fiber bundle models (FBMs) was evaluated systematically for different load redistribution rules. Increasing the range of spatial correlation for FBMs with local load sharing is marked by a transition from ductilelike failure characteristics into brittlelike failure. The study identified a global failure criterion based on macroscopic properties (external load and cumulative damage) that is independent of spatial correlation or load redistribution rules. This general metric could be applied to assess the mechanical stability of complex and heterogeneous systems and thus provide an important component for early warning of a class of geophysical ruptures.
NASA Astrophysics Data System (ADS)
ChePa, Noraziah; Jasin, Noorhayati Md; Bakar, Nur Azzah Abu
2017-10-01
Fail to prevent or control challenges of Information System (IS) implementation have led to the failure of its implementation. Successful implementation of IS has been a challenging task to any organization including government hospitals. Government has invested a big amount of money on information system (IS) projects to improve service delivery in healthcare. However, several of them failed to be implemented successfully due to several factors. This article proposes a prevention model which incorporated Change Management (CM) concepts to avoid the failure of IS implementation, hence ensuring the success of it. Challenges of IS implementation in government hospitals have been discovered. Extensive literature review and deep interview approaches were employed to discover these challenges. A prevention model has been designed to cater the challenges. The model caters three main phases of implementation; pre-implementation, during implementation, and post-implementation by adopting CM practices of Lewin's, Kotter's and Prosci's CM model. Six elements of CM comprising thirteen sub-elements adopted from the three CM models have been used to handle CFFs of Human and Support issues; guiding team, resistance avoidance, IS adoption, enforcement, monitoring, and IS sustainability. Successful practice of the proposed mapping is expected to prevent CFFs to occur, hence ensuring a successful implementation of IS in the hospitals. The proposed model has been presented and successfully evaluated by the domain experts from the selected hospitals. The proposed model is believed to be beneficial for top management, IT practitioners and medical practitioners in preventing IS implementation failure among government hospitals towards ensuring the success implementation.
A Zebrafish Heart Failure Model for Assessing Therapeutic Agents.
Zhu, Xiao-Yu; Wu, Si-Qi; Guo, Sheng-Ya; Yang, Hua; Xia, Bo; Li, Ping; Li, Chun-Qi
2018-03-20
Heart failure is a leading cause of death and the development of effective and safe therapeutic agents for heart failure has been proven challenging. In this study, taking advantage of larval zebrafish, we developed a zebrafish heart failure model for drug screening and efficacy assessment. Zebrafish at 2 dpf (days postfertilization) were treated with verapamil at a concentration of 200 μM for 30 min, which were determined as optimum conditions for model development. Tested drugs were administered into zebrafish either by direct soaking or circulation microinjection. After treatment, zebrafish were randomly selected and subjected to either visual observation and image acquisition or record videos under a Zebralab Blood Flow System. The therapeutic effects of drugs on zebrafish heart failure were quantified by calculating the efficiency of heart dilatation, venous congestion, cardiac output, and blood flow dynamics. All 8 human heart failure therapeutic drugs (LCZ696, digoxin, irbesartan, metoprolol, qiliqiangxin capsule, enalapril, shenmai injection, and hydrochlorothiazide) showed significant preventive and therapeutic effects on zebrafish heart failure (p < 0.05, p < 0.01, and p < 0.001) in the zebrafish model. The larval zebrafish heart failure model developed and validated in this study could be used for in vivo heart failure studies and for rapid screening and efficacy assessment of preventive and therapeutic drugs.
Pickwell, Andrew J; Dorey, Robert A; Mba, David
2011-09-01
Monitoring the condition of complex engineering structures is an important aspect of modern engineering, eliminating unnecessary work and enabling planned maintenance, preventing failure. Acoustic emissions (AE) testing is one method of implementing continuous nondestructive structural health monitoring. A novel thick-film (17.6 μm) AE sensor is presented. Lead zirconate titanate thick films were fabricated using a powder/sol composite ink deposition technique and mechanically patterned to form a discrete thick-film piezoelectric AE sensor. The thick-film sensor was benchmarked against a commercial AE device and was found to exhibit comparable responses to simulated acoustic emissions.
Nanocrystalline cerium oxide materials for solid fuel cell systems
Brinkman, Kyle S
2015-05-05
Disclosed are solid fuel cells, including solid oxide fuel cells and PEM fuel cells that include nanocrystalline cerium oxide materials as a component of the fuel cells. A solid oxide fuel cell can include nanocrystalline cerium oxide as a cathode component and microcrystalline cerium oxide as an electrolyte component, which can prevent mechanical failure and interdiffusion common in other fuel cells. A solid oxide fuel cell can also include nanocrystalline cerium oxide in the anode. A PEM fuel cell can include cerium oxide as a catalyst support in the cathode and optionally also in the anode.
Optimal maintenance policy incorporating system level and unit level for mechanical systems
NASA Astrophysics Data System (ADS)
Duan, Chaoqun; Deng, Chao; Wang, Bingran
2018-04-01
The study works on a multi-level maintenance policy combining system level and unit level under soft and hard failure modes. The system experiences system-level preventive maintenance (SLPM) when the conditional reliability of entire system exceeds SLPM threshold, and also undergoes a two-level maintenance for each single unit, which is initiated when a single unit exceeds its preventive maintenance (PM) threshold, and the other is performed simultaneously the moment when any unit is going for maintenance. The units experience both periodic inspections and aperiodic inspections provided by failures of hard-type units. To model the practical situations, two types of economic dependence have been taken into account, which are set-up cost dependence and maintenance expertise dependence due to the same technology and tool/equipment can be utilised. The optimisation problem is formulated and solved in a semi-Markov decision process framework. The objective is to find the optimal system-level threshold and unit-level thresholds by minimising the long-run expected average cost per unit time. A formula for the mean residual life is derived for the proposed multi-level maintenance policy. The method is illustrated by a real case study of feed subsystem from a boring machine, and a comparison with other policies demonstrates the effectiveness of our approach.
Incidence and risk factors of ventilator associated pneumonia in a tertiary care hospital.
Charles, Mv Pravin; Easow, Joshy M; Joseph, Noyal M; Ravishankar, M; Kumar, Shailesh; Umadevi, Sivaraman
2013-01-01
Ventilator associated pneumonia (VAP) is a type of nosocomial pneumonia associated with increased morbidity and mortality. Knowledge about the incidence and risk factors is necessary to implement preventive measures to reduce mortality in these patients. A prospective study was conducted at a tertiary care teaching hospital for a period of 20 months from November 2009 to July 2011. Patients who were on mechanical ventilation (MV) for more than 48 hours were monitored at frequent intervals for development of VAP using clinical and microbiological criteria until discharge or death. Of the 76 patients, 18 (23.7%) developed VAP during their ICU stay. The incidence of VAP was 53.25 per 1,000 ventilator days. About 94% of VAP cases occurred within the first week of MV. Early-onset and late-onset VAP was observed in 72.2% and 27.8%, respectively. Univariate analysis showed chronic lung failure, H2 blockers usage, and supine head position were significant risk factors for VAP. Logistic regression revealed supine head position as an independent risk factor for VAP. VAP occurred in a sizeable number of patients on MV. Chronic lung failure, H2 blockers usage, and supine head position were the risk factors associated with VAP. Awareness about these risk factors can be used to inform simple and effective preventive measures.
Piccini, Jonathan P; Connolly, Stuart J; Abraham, William T; Healey, Jeff S; Steinberg, Benjamin A; Al-Khalidi, Hussein R; Dignacco, Patricia; van Veldhuisen, Dirk J; Sauer, William H; White, Michel; Wilton, Stephen B; Anand, Inder S; Dufton, Christopher; Marshall, Debra A; Aleong, Ryan G; Davis, Gordon W; Clark, Richard L; Emery, Laura L; Bristow, Michael R
2018-05-01
Few therapies are available for the safe and effective treatment of atrial fibrillation (AF) in patients with heart failure. Bucindolol is a non-selective beta-blocker with mild vasodilator activity previously found to have accentuated antiarrhythmic effects and increased efficacy for preventing heart failure events in patients homozygous for the major allele of the ADRB1 Arg389Gly polymorphism (ADRB1 Arg389Arg genotype). The safety and efficacy of bucindolol for the prevention of AF or atrial flutter (AFL) in these patients has not been proven in randomized trials. The Genotype-Directed Comparative Effectiveness Trial of Bucindolol and Metoprolol Succinate for Prevention of Symptomatic Atrial Fibrillation/Atrial Flutter in Patients with Heart Failure (GENETIC-AF) trial is a multicenter, randomized, double-blinded "seamless" phase 2B/3 trial of bucindolol hydrochloride versus metoprolol succinate, for the prevention of symptomatic AF/AFL in patients with reduced ejection fraction heart failure (HFrEF). Patients with pre-existing HFrEF and recent history of symptomatic AF are eligible for enrollment and genotype screening, and if they are ADRB1 Arg389Arg, eligible for randomization. A total of approximately 200 patients will comprise the phase 2B component and if pre-trial assumptions are met, 620 patients will be randomized at approximately 135 sites to form the Phase 3 population. The primary endpoint is the time to recurrence of symptomatic AF/AFL or mortality over a 24-week follow-up period, and the trial will continue until 330 primary endpoints have occurred. GENETIC-AF is the first randomized trial of pharmacogenetic guided rhythm control, and will test the safety and efficacy of bucindolol compared with metoprolol succinate for the prevention of recurrent symptomatic AF/AFL in patients with HFrEF and an ADRB1 Arg389Arg genotype. (ClinicalTrials.govNCT01970501). Copyright © 2017 Elsevier Inc. All rights reserved.
Packer, Milton
2018-06-01
Sodium-glucose co-transporter-2 (SGLT2) inhibitors reduce the risk of serious heart failure events in patients with type 2 diabetes, but little is known about mechanisms that might mediate this benefit. The most common heart failure phenotype in type 2 diabetes is obesity-related heart failure with a preserved ejection fraction (HFpEF). It has been hypothesized that the synthesis of leptin in this disorder leads to sodium retention and plasma volume expansion as well as to cardiac and renal inflammation and fibrosis. Interestingly, leptin-mediated neurohormonal activation appears to enhance the expression of SGLT2 in the renal tubules, and SGLT2 inhibitors exert natriuretic actions at multiple renal tubular sites in a manner that can oppose the sodium retention produced by leptin. In addition, SGLT2 inhibitors reduce the accumulation and inflammation of perivisceral adipose tissue, thus minimizing the secretion of leptin and its paracrine actions on the heart and kidneys to promote fibrosis. Such fibrosis probably contributes to the impairment of cardiac distensibility and glomerular function that characterizes obesity-related HFpEF. Ongoing clinical trials with SGLT2 inhibitors in heart failure are positioned to confirm or refute the hypothesis that these drugs may favourably influence the course of obesity-related HFpEF by their ability to attenuate the secretion and actions of leptin. © 2018 John Wiley & Sons Ltd.
Development of design criteria for prevention of slope failures : design guide.
DOT National Transportation Integrated Search
1990-03-01
A total of 242 embankments were examined along a 122-mile transect of I-10 and I-20 highways in Louisiana. A total of 99 slope failures had occurred 8-15 years after construction (mean volume = 15,105 cu ft). Most of the failures occurred on slopes g...
40 CFR 63.9375 - What definitions apply to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... malfunction, regardless or whether or not such failure is permitted by this subpart. Engine means any internal.... Malfunction means any sudden, infrequent, and not reasonably preventable failure of air pollution control... potential to cause, the emission limitations in an applicable standard to be exceeded. Failures that are...
40 CFR 63.9375 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... malfunction, regardless or whether or not such failure is permitted by this subpart. Engine means any internal.... Malfunction means any sudden, infrequent, and not reasonably preventable failure of air pollution control... potential to cause, the emission limitations in an applicable standard to be exceeded. Failures that are...
40 CFR 63.9375 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... malfunction, regardless or whether or not such failure is permitted by this subpart. Engine means any internal.... Malfunction means any sudden, infrequent, and not reasonably preventable failure of air pollution control... potential to cause, the emission limitations in an applicable standard to be exceeded. Failures that are...
40 CFR 63.9375 - What definitions apply to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... malfunction, regardless or whether or not such failure is permitted by this subpart. Engine means any internal.... Malfunction means any sudden, infrequent, and not reasonably preventable failure of air pollution control... potential to cause, the emission limitations in an applicable standard to be exceeded. Failures that are...
Current siRNA Targets in the Prevention and Treatment of Intimal Hyperplasia
Pradhan-Nabzdyk, Leena; Huang, Chenyu; LoGerfo, Frank W.; Nabzdyk, Christoph S.
2014-01-01
Intimal hyperplasia (IH) is the leading cause of late vein and prosthetic bypass graft failure. Injury at the time of graft implantation leading to the activation of endothelial cells and dedifferentiation of vascular smooth muscle cells to a synthetic phenotype are known causes of IH. Prior attempts to develop therapy to mitigate these cellular changes to prevent IH and graft failure have failed. Small interfering RNA (siRNA) mediated targeted gene silencing is a promising tool to prevent IH. Several studies have been performed in this direction to target genes that are involved in IH. In this review we discuss siRNA targets that are being investigated for prevention and treatment of IH. PMID:25227753
Dynamic airway pressure-time curve profile (Stress Index): a systematic review.
Terragni, Pierpaolo; Bussone, Guido; Mascia, Luciana
2016-01-01
The assessment of respiratory mechanics at the bedside is necessary in order to identify the most protective ventilatory strategy. Indeed in the last 20 years, adverse effects of positive ventilation to the lung structures have led to a reappraisal of the objectives of mechanical ventilation. The ventilator setting requires repeated readjustment over the period of mechanical ventilation dependency and careful respiratory monitoring to minimize the risks, preventing further injury and permitting the lung and airways healing. Among the different methods that have been proposed and validated, the analysis of dynamic P-t curve (named Stress Index, SI) represents an adequate tool available at the bedside, repeatable and, therefore, able to identify the amount of overdistension occurring in the daily clinical practice, when modifying positive end-expiratory pressure. In this review we will analyze the evidence that supports respiratory mechanics assessment at the bedside and the application of the dynamic P/t curve profile (SI) to optimize protective ventilation in patients with acute respiratory failure.
2014-04-01
the Fanconi Anemia Pathway- Regulated Nucleases in Genome Maintenance for Preventing Bone Marrow Failure and Cancer PRINCIPAL INVESTIGATOR...GRANT NUMBER 4. TITLE AND SUBTITLE A Biochemical Approach to Understanding the Fanconi Anemia Pathway-Regulated Nucleases in Genome Maintenance for...Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Fanconi anemia is the most prevalent inherited BMF syndromes, caused by mutations in
Failure Mechanisms of Brittle Rocks under Uniaxial Compression
NASA Astrophysics Data System (ADS)
Liu, Taoying; Cao, Ping
2017-09-01
The behaviour of a rock mass is determined not only by the properties of the rock matrix, but mostly by the presence and properties of discontinuities or fractures within the mass. The compression test on rock-like specimens with two prefabricated transfixion fissures, made by pulling out the embedded metal inserts in the pre-cured period was carried out on the servo control uniaxial loading tester. The influence of the geometry of pre-existing cracks on the cracking processes was analysed with reference to the experimental observation of crack initiation and propagation from pre-existing flaws. Based on the rock fracture mechanics and the stress-strain curves, the evolution failure mechanism of the fissure body was also analyzed on the basis of exploring the law of the compression-shear crack initiation, wing crack growth and rock bridge connection. Meanwhile, damage fracture mechanical models of a compression-shear rock mass are established when the rock bridge axial transfixion failure, tension-shear combined failure, or wing crack shear connection failure occurs on the specimen under axial compression. This research was of significance in studying the failure mechanism of fractured rock mass.
Mechanisms of hypoglycemia unawareness and implications in diabetic patients
Martín-Timón, Iciar; del Cañizo-Gómez, Francisco Javier
2015-01-01
Hypoglycemia unawareness (HU) is defined at the onset of neuroglycopenia before the appearance of autonomic warning symptoms. It is a major limitation to achieving tight diabetes and reduced quality of life. HU occurs in approximately 40% of people with type 1 diabetes mellitus (T1DM) and with less frequency in T2DM. Though the aetiology of HU is multifactorial, possible mechanisms include chronic exposure to low blood glucose, antecedent hypoglycaemia, recurrent severe hypoglycaemia and the failure of counter-regulatory hormones. Clinically it manifests as the inability to recognise impeding hypoglycaemia by symptoms, but the mechanisms and mediators remain largely unknown. Prevention and management of HU is complex, and can only be achieved by a multifactorial intervention of clinical care and structured patient education by the diabetes team. Less know regarding the impact of medications on the development or recognition of this condition in patients with diabetes. Several medications are thought to worsen or promote HU, whereas others may have an attenuating effect on the problem. This article reviews recent advances in how the brain senses and responds to hypoglycaemia, novel mechanisms by which people with insulin-treated diabetes develop HU and impaired counter-regulatory responses. The consequences that HU has on the person with diabetes and their family are also described. Finally, it examines the evidence for prevention and treatment of HU, and summarizes the effects of medications that may influence it. PMID:26185599
Development of failure model for nickel cadmium cells
NASA Technical Reports Server (NTRS)
Gupta, A.
1980-01-01
The development of a method for the life prediction of nickel cadmium cells is discussed. The approach described involves acquiring an understanding of the mechanisms of degradation and failure and at the same time developing nondestructive evaluation techniques for the nickel cadmium cells. The development of a statistical failure model which will describe the mechanisms of degradation and failure is outlined.
NASA Astrophysics Data System (ADS)
Xu, Yuan; Dai, Feng
2018-03-01
A novel method is developed for characterizing the mechanical response and failure mechanism of brittle rocks under dynamic compression-shear loading: an inclined cylinder specimen using a modified split Hopkinson pressure bar (SHPB) system. With the specimen axis inclining to the loading direction of SHPB, a shear component can be introduced into the specimen. Both static and dynamic experiments are conducted on sandstone specimens. Given carefully pulse shaping, the dynamic equilibrium of the inclined specimens can be satisfied, and thus the quasi-static data reduction is employed. The normal and shear stress-strain relationships of specimens are subsequently established. The progressive failure process of the specimen illustrated via high-speed photographs manifests a mixed failure mode accommodating both the shear-dominated failure and the localized tensile damage. The elastic and shear moduli exhibit certain loading-path dependence under quasi-static loading but loading-path insensitivity under high loading rates. Loading rate dependence is evidently demonstrated through the failure characteristics involving fragmentation, compression and shear strength and failure surfaces based on Drucker-Prager criterion. Our proposed method is convenient and reliable to study the dynamic response and failure mechanism of rocks under combined compression-shear loading.
Deformation and failure mechanisms of graphite/epoxy composites under static loading
NASA Technical Reports Server (NTRS)
Clements, L. L.
1981-01-01
The mechanisms of deformation and failure of graphite epoxy composites under static loading were clarified. The influence of moisture and temperature upon these mechanisms were also investigated. Because the longitudinal tensile properties are the most critical to the performance of the composite, these properties were investigated in detail. Both ultimate and elastic mechanical properties were investigated, but the study of mechanisms emphasized those leading to failure of the composite. The graphite epoxy composite selected for study was the system being used in several NASA sponsored flight test programs.
Thurner, P J; Wyss, P; Voide, R; Stauber, M; Stampanoni, M; Sennhauser, U; Müller, R
2006-08-01
Synchrotron radiation micro-computed tomography (SRmicroCT) is a very useful technique when it comes to three-dimensional (3D) imaging of complex internal and external geometries. Being a fully non-destructive technique, SRmicroCT can be combined with other experiments in situ for functional imaging. We are especially interested in the combination of SRmicroCT with mechanical testing in order to gain new insights in the failure mechanism of trabecular bone. This interest is motivated by the immense costs in health care due to patients suffering from osteoporosis, a systemic skeletal disease resulting in decreased bone stability and increased fracture risk. To better investigate the different failure mechanisms on the microlevel, we have developed a novel in situ mechanical compression device, capable of exerting both static and dynamic displacements on experimental samples. The device was calibrated for mechanical testing using solid aluminum and bovine trabecular bone samples. To study different failure mechanisms in trabecular bone, we compared a fatigued and a non-fatigued bovine bone sample with respect to failure initiation and propagation. The fatigued sample failed in a burst-like fashion in contrast to the non-fatigued sample, which exhibited a distinct localized failure band. Moreover, microscopic cracks - microcracks and microfractures - were uncovered in a 3D fashion illustrating the failure process in great detail. The majority of these cracks were connected to a bone surface. The data also showed that the classification of microcracks and -fractures from 2D section can sometimes be ambiguous, which is also true for the distinction of diffuse and distinct microdamage. Detailed investigation of the failure mechanism in these samples illustrated that trabecular bone often fails in delamination, providing a mechanism for energy dissipation while conserving trabecular bone architecture. In the future, this will allow an even better understanding of bone mechanics related to its hierarchical structural organization.
Identification of Bearing Failure Using Signal Vibrations
NASA Astrophysics Data System (ADS)
Yani, Irsyadi; Resti, Yulia; Burlian, Firmansyah
2018-04-01
Vibration analysis can be used to identify damage to mechanical systems such as journal bearings. Identification of failure can be done by observing the resulting vibration spectrum by measuring the vibration signal occurring in a mechanical system Bearing is one of the engine elements commonly used in mechanical systems. The main purpose of this research is to monitor the bearing condition and to identify bearing failure on a mechanical system by observing the resulting vibration. Data collection techniques based on recordings of sound caused by the vibration of the mechanical system were used in this study, then created a database system based bearing failure due to vibration signal recording sounds on a mechanical system The next step is to group the bearing damage by type based on the databases obtained. The results show the percentage of success in identifying bearing damage is 98 %.
3D modeling of missing pellet surface defects in BWR fuel
Spencer, B. W.; Williamson, R. L.; Stafford, D. S.; ...
2016-07-26
One of the important roles of cladding in light water reactor fuel rods is to prevent the release of fission products. To that end, it is essential that the cladding maintain its integrity under a variety of thermal and mechanical loading conditions. Local geometric irregularities in fuel pellets caused by manufacturing defects known as missing pellet surfaces (MPS) can in some circumstances lead to elevated cladding stresses that are sufficiently high to cause cladding failure. Accurate modeling of these defects can help prevent these types of failures. The BISON nuclear fuel performance code developed at Idaho National Laboratory can bemore » used to simulate the global thermo-mechanical fuel rod behavior, as well as the local response of regions of interest, in either 2D or 3D. In either case, a full set of models to represent the thermal and mechanical properties of the fuel, cladding and plenum gas is employed. A procedure for coupling 2D full-length fuel rod models to detailed 3D models of the region of the rod containing a MPS defect is detailed in this paper. The global and local model each contain appropriate physics and behavior models for nuclear fuel. This procedure is demonstrated on a simulation of a boiling water reactor (BWR) fuel rod containing a pellet with an MPS defect, subjected to a variety of transient events, including a control blade withdrawal and a ramp to high power. The importance of modeling the local defect using a 3D model is highlighted by comparing 3D and 2D representations of the defective pellet region. Finally, parametric studies demonstrate the effects of the choice of gaseous swelling model and of the depth and geometry of the MPS defect on the response of the cladding adjacent to the defect.« less
Light water reactor lower head failure analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rempe, J.L.; Chavez, S.A.; Thinnes, G.L.
1993-10-01
This document presents the results from a US Nuclear Regulatory Commission-sponsored research program to investigate the mode and timing of vessel lower head failure. Major objectives of the analysis were to identify plausible failure mechanisms and to develop a method for determining which failure mode would occur first in different light water reactor designs and accident conditions. Failure mechanisms, such as tube ejection, tube rupture, global vessel failure, and localized vessel creep rupture, were studied. Newly developed models and existing models were applied to predict which failure mechanism would occur first in various severe accident scenarios. So that a broadermore » range of conditions could be considered simultaneously, calculations relied heavily on models with closed-form or simplified numerical solution techniques. Finite element techniques-were employed for analytical model verification and examining more detailed phenomena. High-temperature creep and tensile data were obtained for predicting vessel and penetration structural response.« less
In situ transmission electron microscopy of transistor operation and failure.
Wang, Baoming; Islam, Zahabul; Haque, Aman; Chabak, Kelson; Snure, Michael; Heller, Eric; Glavin, Nicholas
2018-08-03
Microscopy is typically used as a post-mortem analytical tool in performance and reliability studies on nanoscale materials and devices. In this study, we demonstrate real time microscopy of the operation and failure of AlGaN/GaN high electron mobility transistors inside the transmission electron microscope. Loading until failure was performed on the electron transparent transistors to visualize the failure mechanisms caused by self-heating. At lower drain voltages, thermo-mechanical stresses induce irreversible microstructural deformation, mostly along the AlGaN/GaN interface, to initiate the damage process. At higher biasing, the self-heating deteriorates the gate and catastrophic failure takes place through metal/semiconductor inter-diffusion and/or buffer layer breakdown. This study indicates that the current trend of recreating the events, from damage nucleation to catastrophic failure, can be replaced by in situ microscopy for a quick and accurate account of the failure mechanisms.
Development of failure mechanisms for fasteners in the United States
Douglas R. Rammer; Philip Line
2006-01-01
In the 2001 National Design Specifications® for Wood Construction (NDS), Appendix E was added to explicitly address wood failure mechanisms that may occur in fasteners. One approach to estimate design capacities for net section, row tear out, and group tear failure mechanisms is presented in Appendix E of the 2001 NDS. Since the 2001 NDS, efforts are being untaken to...
Yilgor, Caglar; Sogunmez, Nuray; Boissiere, Louis; Yavuz, Yasemin; Obeid, Ibrahim; Kleinstück, Frank; Pérez-Grueso, Francisco Javier Sánchez; Acaroglu, Emre; Haddad, Sleiman; Mannion, Anne F; Pellise, Ferran; Alanay, Ahmet
2017-10-04
The restoration of normal sagittal alignment is a critical goal in adult spinal deformity surgery to achieve favorable outcomes and prevent mechanical complications. Schwab sagittal modifiers have been accepted as targets for appropriate alignment, but addressing these targets does not always prevent high mechanical complication or revision rates. This may be because the linear absolute numerical parameters do not cover the whole pelvic incidence spectrum and the distribution of lordosis, pelvic anteversion, and negative malalignment are not considered as potential causes of failure. The aim of the present study was to develop and validate a score based on pelvic-incidence-based proportional parameters to better predict mechanical complications. Two hundred and twenty-two patients (168 women and 54 men) followed for ≥2 years after posterior fusion at ≥4 levels were included in the study. The mean age (and standard deviation) was 52.2 ± 19.3 years (range, 18 to 84 years), and the mean duration of follow-up was 28.8 ± 8.2 months (range, 24 to 62 months). The global alignment and proportion (GAP) score was developed and validated in groups of patients randomly assigned to derivation (n = 148, 66.7%) and validation (n = 74, 33.3%) cohorts. GAP score parameters were relative pelvic version (the measured minus the ideal sacral slope), relative lumbar lordosis (the measured minus the ideal lumbar lordosis), lordosis distribution index (the L4-S1 lordosis divided by the L1-S1 lordosis multiplied by 100), relative spinopelvic alignment (the measured minus the ideal global tilt), and an age factor. Proximal and distal junctional kyphosis and/or failure, rod breakage, and other implant-related complications were considered mechanical complications. The predictive accuracy of the GAP score was analyzed using receiver operating characteristic (ROC) analyses. Associations between GAP categories and mechanical complications and revisions were analyzed using Cochran-Armitage tests. In the validation cohort, 32 patients (43%) experienced mechanical complications and 17 (23%) underwent mechanical revision. The area under curve for the GAP score predicting mechanical complications was 0.92 (standard error [SE] = 0.034, p < 0.001, 95% [confidence interval [CI] = 0.85 to 0.98). Postoperatively, patients with a proportioned spinopelvic state according to the GAP score had a mechanical complication rate of 6% while those with a moderately or severely disproportioned spinopelvic state had rates of 47% and 95%, respectively. The GAP score is a new pelvic-incidence-based proportional method of analyzing the sagittal plane that predicts mechanical complications in patients undergoing surgery for adult spinal deformity. Setting surgical goals according to the GAP score may decrease the prevalence of mechanical complications.
Systems Biology and Biomechanical Model of Heart Failure
Louridas, George E; Lourida, Katerina G
2012-01-01
Heart failure is seen as a complex disease caused by a combination of a mechanical disorder, cardiac remodeling and neurohormonal activation. To define heart failure the systems biology approach integrates genes and molecules, interprets the relationship of the molecular networks with modular functional units, and explains the interaction between mechanical dysfunction and cardiac remodeling. The biomechanical model of heart failure explains satisfactorily the progression of myocardial dysfunction and the development of clinical phenotypes. The earliest mechanical changes and stresses applied in myocardial cells and/or myocardial loss or dysfunction activate left ventricular cavity remodeling and other neurohormonal regulatory mechanisms such as early release of natriuretic peptides followed by SAS and RAAS mobilization. Eventually the neurohormonal activation and the left ventricular remodeling process are leading to clinical deterioration of heart failure towards a multi-organic damage. It is hypothesized that approaching heart failure with the methodology of systems biology we promote the elucidation of its complex pathophysiology and most probably we can invent new therapeutic strategies. PMID:22935019
Clinical utility of sympathetic blockade in cardiovascular disease management.
Park, Chan Soon; Lee, Hae-Young
2017-04-01
A dysregulated sympathetic nervous system is a major factor in the development and progression of cardiovascular disease; thus, understanding the mechanism and function of the sympathetic nervous system and appropriately regulating sympathetic activity to treat various cardiovascular diseases are crucial. Areas covered: This review focused on previous studies in managing hypertension, atrial fibrillation, coronary artery disease, heart failure, and perioperative management with sympathetic blockade. We reviewed both pharmacological and non-pharmacological management. Expert commentary: Chronic sympathetic nervous system activation is related to several cardiovascular diseases mediated by various pathways. Advancement in measuring sympathetic activity makes visualizing noninvasively and evaluating the activation level even in single fibers possible. Evidence suggests that sympathetic blockade still has a role in managing hypertension and controlling the heart rate in atrial fibrillation. For ischemic heart disease, beta-adrenergic receptor antagonists have been considered a milestone drug to control symptoms and prevent long-term adverse effects, although its clinical implication has become less potent in the era of successful revascularization. Owing to pathologic involvement of sympathetic nervous system activation in heart failure progression, sympathetic blockade has proved its value in improving the clinical course of patients with heart failure.
Macrodamage Accumulation Model for a Human Femur
2017-01-01
The objective of this study was to more fully understand the mechanical behavior of bone tissue that is important to find an alternative material to be used as an implant and to develop an accurate model to predict the fracture of the bone. Predicting and preventing bone failure is an important area in orthopaedics. In this paper, the macrodamage accumulation models in the bone tissue have been investigated. Phenomenological models for bone damage have been discussed in detail. In addition, 3D finite element model of the femur prepared from imaging data with both cortical and trabecular structures is delineated using MIMICS and ANSYS® and simulated as a composite structure. The damage accumulation occurring during cyclic loading was analyzed for fatigue scenario. We found that the damage accumulates sooner in the multiaxial than in the uniaxial loading condition for the same number of cycles, and the failure starts in the cortical bone. The damage accumulation behavior seems to follow a three-stage growth: a primary phase, a secondary phase of damage growth marked by linear damage growth, and a tertiary phase that leads to failure. Finally, the stiffness of the composite bone comprising the cortical and trabecular bone was significantly different as expected. PMID:28951659
Progressive Failure Analysis Methodology for Laminated Composite Structures
NASA Technical Reports Server (NTRS)
Sleight, David W.
1999-01-01
A progressive failure analysis method has been developed for predicting the failure of laminated composite structures under geometrically nonlinear deformations. The progressive failure analysis uses C(exp 1) shell elements based on classical lamination theory to calculate the in-plane stresses. Several failure criteria, including the maximum strain criterion, Hashin's criterion, and Christensen's criterion, are used to predict the failure mechanisms and several options are available to degrade the material properties after failures. The progressive failure analysis method is implemented in the COMET finite element analysis code and can predict the damage and response of laminated composite structures from initial loading to final failure. The different failure criteria and material degradation methods are compared and assessed by performing analyses of several laminated composite structures. Results from the progressive failure method indicate good correlation with the existing test data except in structural applications where interlaminar stresses are important which may cause failure mechanisms such as debonding or delaminations.
Hashemzadeh, Mehrnoosh; Park, Shery; Ju, Hee; Movahed, Mohammad R
2013-12-01
Cardiovascular disease is the leading cause of death in American adults. Furthermore, the incidence of congestive heart failure is on the rise as a major cause of hospitalization and mortality in this population. Angiotensin Converting Enzyme (ACE) inhibitors prevent the production of angiotensin II, which has been shown to reduce mortality in patients with congestive heart failure. Angiotensin II receptor blockers (ARB) were developed as a direct inhibitor of angiotensin II. ARBs have been shown to be effective in the treatment of patients with systolic heart failure but do not cause chronic coughing which is a common side effect of ACE inhibitors. In theory, a compound that has the combined effect of an ACE inhibitor and an ARB should be more effective in treating heart failure patients than either agents alone. Therefore, the purpose of this manuscript is to design and discuss the benefits of a new molecule, which combines captopril, an ACE inhibitor, with losartan, an ARB. In this experiment Captopril and Losartan were modified and synthesized separately and combined by homo or mono coupling. This was achieved by taking advantage of PEG (Polyethylene glycol) as a linker. It is expected that this molecule will have the combined modes of action of both ACEs and ARBs. Benefits from combination therapy include; increased efficacy, reduced adverse effects, convenience, compliance, and prolonged duration. Consequently, this combined molecule is expected to block the production of angiotensin II more efficiently and effectively. Although captopril and losartan work in the same system by blocking the effect of angiotensin II they have different action sites and mechanisms some patents are also discussed. Losartan blocks the AT1 receptor which is expressed on the cell surface, while captopril inhibits ACE, preventing production of angiotensin II, which is present in both the plasma and on the cell surface, especially on endothelial and smooth muscle cells.
Coupled Mechanical-Electrochemical-Thermal Analysis of Failure Propagation in Lithium-ion Batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Chao; Santhanagopalan, Shriram; Pesaran, Ahmad
2016-07-28
This is a presentation given at the 12th World Congress for Computational Mechanics on coupled mechanical-electrochemical-thermal analysis of failure propagation in lithium-ion batteries for electric vehicles.
Psychobiology of depression/distress in congestive heart failure
Hassan, Mustafa; Sheps, David S.
2011-01-01
Heart failure affects millions of Americans and new diagnosis rates are expected to almost triple over the next 30 years as our population ages. Affective disorders including clinical depression and anxiety are common in patients with congestive heart failure. Furthermore, the presence of these disorders significantly impacts quality of life, medical outcomes, and healthcare service utilization. In recent years, the literature has attempted to describe potential pathophysiologic mechanisms relating affective disorders and psychosocial stress to heart failure. Several potential mechanisms have been proposed including autonomic nervous system dysfunction, inflammation, cardiac arrhythmias, and altered platelet function. These mechanisms are reviewed in this article. Additional novel mechanisms such as mental stress-induced myocardial ischemia are also discussed. PMID:18368481
The role of the renal specialist nurse in prevention of renal failure.
Hurst, J
2002-01-01
This article will investigate the care required for those with reduced renal function before renal replacement therapy (RRT) commences. Renal nurses are often involved with the technical, monitoring and evaluative aspects of RRT for those with end stage renal failure. However, many patients may experience reduced renal function many years before reaching the stage of needing RRT. Renal nurses are already involved in the preparation of patients for RRT, but are not presently exercising their specialist skills in the period before this time by contributing to the prevention of end stage renal failure (ESRF). Screening programmes carried out in various parts of the world demonstrate that many members of the population have undetected renal insufficiency, and may benefit from intervention from the nephrology team to prevent further renal dysfunction. It is for this group of patients that this article will consider the potential for the renal nurse to expand their scope of practice.
Caballero Morales, Santiago Omar
2013-01-01
The application of Preventive Maintenance (PM) and Statistical Process Control (SPC) are important practices to achieve high product quality, small frequency of failures, and cost reduction in a production process. However there are some points that have not been explored in depth about its joint application. First, most SPC is performed with the X-bar control chart which does not fully consider the variability of the production process. Second, many studies of design of control charts consider just the economic aspect while statistical restrictions must be considered to achieve charts with low probabilities of false detection of failures. Third, the effect of PM on processes with different failure probability distributions has not been studied. Hence, this paper covers these points, presenting the Economic Statistical Design (ESD) of joint X-bar-S control charts with a cost model that integrates PM with general failure distribution. Experiments showed statistically significant reductions in costs when PM is performed on processes with high failure rates and reductions in the sampling frequency of units for testing under SPC. PMID:23527082
Fritz, Deborah; McKenzie, Patricia
2014-01-01
Patients with pneumonia, chronic obstructive pulmonary disease (COPD), and heart failure make frequent visits to the emergency department. Heart failure alone is the reason for more than 1 million emergency department visits annually in the United States. This article describes strategies home care clinicians can use to prevent unnecessary emergency department visits for patients with pneumonia, COPD and heart failure.
Evaluation of the tensile strength of the human ureter - Preliminary results.
Shilo, Yaniv; Pichamuthu, Joseph E; Averch, Timothy D; Vorp, David A
2014-09-15
Introduction: Ureteral injuries such as avulsion are directly related to mechanical damage of the ureter. Understanding the tensile strength of this tissue may assist in prevention of iatrogenic injuries. Few published studies have looked at the mechanical properties of the animal ureter, and of those none have determined the tensile strength of the human ureter. Therefore, the purpose of this work was to determine the tensile strength of the human ureter. Materials and Methods: We harvested 11 human proximal ureters from patients who were undergoing nephrectomy for either kidney tumors or non-functioning kidney. The specimens were then cut into multiple circumferentially and longitudinally-oriented tissue strips for tensile testing. Strips were uniaxially stretched to failure in a tensile testing machine. The corresponding force and displacement were recorded. Finally, stress at failure was noted as the tensile strength of the sample. Circumferential tensile strength was also compared in the proximal and distal regions of the specimens. Results: The tensile strength of the ureter in circumferential and longitudinal orientations was found to be 457.52±33.74 Ncm-2 and 902.43±122.08 Ncm-2, respectively (p<0.001). The circumferential strength in the proximal portion of the ureter was 409.89±35.13 Ncm-2 in comparison to 502.89±55.85 Ncm-2 in the distal portion (p=0.08). Conclusions: The circumferential tensile strength of the ureter was found to be significantly lower than the longitudinal strength. Circumferential tensile strength was also lower with more proximal parts of the ureter. This information may be important for the design of "intelligent" devices and simulators in order to prevent complications.
Evaluation of the tensile strength of the human ureter--preliminary results.
Shilo, Yaniv; Pichamuthu, Joseph E; Averch, Timothy D; Vorp, David A
2014-12-01
Ureteral injuries such as avulsion are directly related to mechanical damage of the ureter. Understanding the tensile strength of this tissue may assist in prevention of iatrogenic injuries. Few published studies have looked at the mechanical properties of the animal ureter and, of those, none has determined the tensile strength of the human ureter. Therefore, the purpose of this work was to determine the tensile strength of the human ureter. We harvested 11 human proximal ureters from patients who were undergoing nephrectomy for either kidney tumors or nonfunctioning kidney. The specimens were then cut into multiple circumferentially and longitudinally oriented tissue strips for tensile testing. Strips were uniaxially stretched to failure in a tensile testing machine. The corresponding force and displacement were recorded. Finally, stress at failure was noted as the tensile strength of the sample. Circumferential tensile strength was also compared in the proximal and distal regions of the specimens. The tensile strength of the ureter in circumferential and longitudinal orientations was found to be 457.52±33.74 Ncm(-2) and 902.43±122.08 Ncm(-2), respectively (P<0.001). The circumferential strength in the proximal portion of the ureter was 409.89±35.13 Ncm(-2) in comparison with 502.89±55.85 Ncm(-2) in the distal portion (P=0.08). The circumferential tensile strength of the ureter was found to be significantly lower than the longitudinal strength. Circumferential tensile strength was also lower with more proximal parts of the ureter. This information may be important for the design of "intelligent" devices and simulators to prevent complications.
Green technologies for reducing slope erosion.
DOT National Transportation Integrated Search
2010-01-01
As climate change alters precipitation patterns, departments of transportation will increasingly face the problem of : slope failures, which already cost California millions of dollars in repair work annually. Caltrans hopes to prevent : these failur...
Data and Statistics: Heart Failure
... commit" type="submit" value="Submit" /> Related CDC Web Sites Heart Disease Stroke High Blood Pressure Salt ... to Prevent and Control Chronic Diseases Million Hearts® Web Sites with More Information About Heart Failure For ...
Code of Federal Regulations, 2013 CFR
2013-01-01
... exhaust heat exchanger must incorporate means to prevent blockage of the exhaust port after any internal heat exchanger failure. (i) For the purpose of compliance with § 23.603, the failure of any part of the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... exhaust heat exchanger must incorporate means to prevent blockage of the exhaust port after any internal heat exchanger failure. (i) For the purpose of compliance with § 23.603, the failure of any part of the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... exhaust heat exchanger must incorporate means to prevent blockage of the exhaust port after any internal heat exchanger failure. (i) For the purpose of compliance with § 23.603, the failure of any part of the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... exhaust heat exchanger must incorporate means to prevent blockage of the exhaust port after any internal heat exchanger failure. (i) For the purpose of compliance with § 23.603, the failure of any part of the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... exhaust heat exchanger must incorporate means to prevent blockage of the exhaust port after any internal heat exchanger failure. (i) For the purpose of compliance with § 23.603, the failure of any part of the...
Kitano, Tomoya; Iwasaki, Kiyotaka
The EVAHEART Left Ventricular Assist System (LVAS) was designed for the long-term support of a patient with severe heart failure. It has an original water lubrication system for seal and bearing and wear on these parts was considered one of its critical failure modes. A durability test focusing on wear was designed herein. We developed a mock loop, which generates a physiologic pulsatile flow and is sufficiently durable for a long-term test. The pulsatile load and the low fluid viscosity enable the creation of a severe condition for the mechanical seal. A total of 18 EVAHEART blood pumps completed 2 years of operation under the pulsatile condition without any failure. It indicated the EVAHEART blood pump had a greater than 90% reliability with a 88% confidence level. The test was continued with six blood pumps and achieved an average of 8.6 years, which was longer than the longest clinical use in Japan. The test result showed that no catastrophic, critical, marginal, or minor failures of the blood pump or their symptoms were observed. The seal performance was maintained after the test. Moreover, the surface roughness did not change, which showed any burn or abnormal wear occurred. The original water lubrication system equipped in EVAHEART LVAS prevent severe wear on the seal and the bearing, and it can be used in the bridge to transplant and destination therapy.
Mechanical ventilation during extracorporeal membrane oxygenation.
Schmidt, Matthieu; Pellegrino, Vincent; Combes, Alain; Scheinkestel, Carlos; Cooper, D Jamie; Hodgson, Carol
2014-01-21
The timing of extracorporeal membrane oxygenation (ECMO) initiation and its outcome in the management of respiratory and cardiac failure have received considerable attention, but very little attention has been given to mechanical ventilation during ECMO. Mechanical ventilation settings in non-ECMO studies have been shown to have an effect on survival and may also have contributed to a treatment effect in ECMO trials. Protective lung ventilation strategies established for non-ECMO-supported respiratory failure patients may not be optimal for more severe forms of respiratory failure requiring ECMO support. The influence of positive end-expiratory pressure on the reduction of the left ventricular compliance may be a matter of concern for patients receiving ECMO support for cardiac failure. The objectives of this review were to describe potential mechanisms for lung injury during ECMO for respiratory or cardiac failure, to assess the possible benefits from the use of ultra-protective lung ventilation strategies and to review published guidelines and expert opinions available on mechanical ventilation-specific management of patients requiring ECMO, including mode and ventilator settings. Articles were identified through a detailed search of PubMed, Ovid, Cochrane databases and Google Scholar. Additional references were retrieved from the selected studies. Growing evidence suggests that mechanical ventilation settings are important in ECMO patients to minimize further lung damage and improve outcomes. An ultra-protective ventilation strategy may be optimal for mechanical ventilation during ECMO for respiratory failure. The effects of airway pressure on right and left ventricular afterload should be considered during venoarterial ECMO support of cardiac failure. Future studies are needed to better understand the potential impact of invasive mechanical ventilation modes and settings on outcomes.
Mechanical ventilation during extracorporeal membrane oxygenation
2014-01-01
The timing of extracorporeal membrane oxygenation (ECMO) initiation and its outcome in the management of respiratory and cardiac failure have received considerable attention, but very little attention has been given to mechanical ventilation during ECMO. Mechanical ventilation settings in non-ECMO studies have been shown to have an effect on survival and may also have contributed to a treatment effect in ECMO trials. Protective lung ventilation strategies established for non-ECMO-supported respiratory failure patients may not be optimal for more severe forms of respiratory failure requiring ECMO support. The influence of positive end-expiratory pressure on the reduction of the left ventricular compliance may be a matter of concern for patients receiving ECMO support for cardiac failure. The objectives of this review were to describe potential mechanisms for lung injury during ECMO for respiratory or cardiac failure, to assess the possible benefits from the use of ultra-protective lung ventilation strategies and to review published guidelines and expert opinions available on mechanical ventilation-specific management of patients requiring ECMO, including mode and ventilator settings. Articles were identified through a detailed search of PubMed, Ovid, Cochrane databases and Google Scholar. Additional references were retrieved from the selected studies. Growing evidence suggests that mechanical ventilation settings are important in ECMO patients to minimize further lung damage and improve outcomes. An ultra-protective ventilation strategy may be optimal for mechanical ventilation during ECMO for respiratory failure. The effects of airway pressure on right and left ventricular afterload should be considered during venoarterial ECMO support of cardiac failure. Future studies are needed to better understand the potential impact of invasive mechanical ventilation modes and settings on outcomes. PMID:24447458
Effect of Progressive Heart Failure on Cerebral Hemodynamics and Monoamine Metabolism in CNS.
Mamalyga, M L; Mamalyga, L M
2017-07-01
Compensated and decompensated heart failure are characterized by different associations of disorders in the brain and heart. In compensated heart failure, the blood flow in the common carotid and basilar arteries does not change. Exacerbation of heart failure leads to severe decompensation and is accompanied by a decrease in blood flow in the carotid and basilar arteries. Changes in monoamine content occurring in the brain at different stages of heart failure are determined by various factors. The functional exercise test showed unequal monoamine-synthesizing capacities of the brain in compensated and decompensated heart failure. Reduced capacity of the monoaminergic systems in decompensated heart failure probably leads to overstrain of the central regulatory mechanisms, their gradual exhaustion, and failure of the compensatory mechanisms, which contributes to progression of heart failure.
NASA Astrophysics Data System (ADS)
Park, Jung-Yong; Jung, Yong-Keun; Park, Jong-Jin; Kang, Yong-Ho
2002-05-01
Failures of turbine blades are identified as the leading causes of unplanned outages for steam turbine. Accidents of low-pressure turbine blade occupied more than 70 percent in turbine components. Therefore, the prevention of failures for low pressure turbine blades is certainly needed. The procedure is illustrated by the case study. This procedure is used to guide, and support the plant manager's decisions to avoid a costly, unplanned outage. In this study, we are trying to find factors of failures in LP turbine blade and to make three steps to approach the solution of blade failure. First step is to measure natural frequency in mockup test and to compare it with nozzle passing frequency. Second step is to use FEM and to calculate the natural frequencies of 7 blades and 10 blades per group in BLADE code. Third step is to find natural frequencies of grouped blade off the nozzle passing frequency.
Creep-Fatigue Failure Diagnosis
Holdsworth, Stuart
2015-01-01
Failure diagnosis invariably involves consideration of both associated material condition and the results of a mechanical analysis of prior operating history. This Review focuses on these aspects with particular reference to creep-fatigue failure diagnosis. Creep-fatigue cracking can be due to a spectrum of loading conditions ranging from pure cyclic to mainly steady loading with infrequent off-load transients. These require a range of mechanical analysis approaches, a number of which are reviewed. The microstructural information revealing material condition can vary with alloy class. In practice, the detail of the consequent cracking mechanism(s) can be camouflaged by oxidation at high temperatures, although the presence of oxide on fracture surfaces can be used to date events leading to failure. Routine laboratory specimen post-test examination is strongly recommended to characterise the detail of deformation and damage accumulation under known and well-controlled loading conditions to improve the effectiveness and efficiency of failure diagnosis. PMID:28793676
The use of light emission in failure analysis of CMOS ICs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hawkins, C.F.; Soden, J.M.; Cole, E.I. Jr.
1990-01-01
The use of photon emission for analyzing failure mechanisms and defects in CMOS ICs is presented. Techniques are given for accurate identification and spatial localization of failure mechanisms and physical defects, including defects such as short and open circuits which do not themselves emit photons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stacey M. L. Hendrickson; April M. Whaley; Ronald L. Boring
The Office of Nuclear Regulatory Research (RES) is sponsoring work in response to a Staff Requirements Memorandum (SRM) directing an effort to establish a single human reliability analysis (HRA) method for the agency or guidance for the use of multiple methods. As part of this effort an attempt to develop a comprehensive HRA qualitative approach is being pursued. This paper presents a draft of the method’s middle layer, a part of the qualitative analysis phase that links failure mechanisms to performance shaping factors. Starting with a Crew Response Tree (CRT) that has identified human failure events, analysts identify potential failuremore » mechanisms using the mid-layer model. The mid-layer model presented in this paper traces the identification of the failure mechanisms using the Information-Diagnosis/Decision-Action (IDA) model and cognitive models from the psychological literature. Each failure mechanism is grouped according to a phase of IDA. Under each phase of IDA, the cognitive models help identify the relevant performance shaping factors for the failure mechanism. The use of IDA and cognitive models can be traced through fault trees, which provide a detailed complement to the CRT.« less
Ali, Husain Shabbir; Hassan, Ibrahim Fawzy; George, Saibu
2016-04-14
Pulmonary infections caused by Pneumocystis jirovecii in immunocompromised host can be associated with cysts, pneumatoceles and air leaks that can progress to pneumomediastinum and pneumothoraxes. In such cases, it can be challenging to maintain adequate gas exchange by conventional mechanical ventilation and at the same time prevent further ventilator-induced lung injury. We report a young HIV positive male with poorly compliant lungs and pneumomediastinum secondary to severe Pneumocystis infection, rescued with veno-venous extra corporeal membrane oxygenation (V-V ECMO). A 26 year old male with no significant past medical history was admitted with fever, cough and shortness of breath. He initially required non-invasive ventilation for respiratory failure. However, his respiratory function progressively deteriorated due to increasing pulmonary infiltrates and development of pneumomediastinum, eventually requiring endotracheal intubation and invasive ventilation. Despite attempts at optimizing gas exchange by ventilatory maneuvers, patients' pulmonary parameters worsened necessitating rescue ECMO therapy. The introduction of V-V ECMO facilitated the use of ultra-protective lung ventilation and prevented progression of pneumomediastinum, maintaining optimal gas exchange. It allowed time for the antibiotics to show effect and pulmonary parenchyma to heal. Further diagnostic workup revealed Pneumocystis jirovecii as the causative organism for pneumonia and serology confirmed Human Immunodeficiency Virus infection. Patient was successfully treated with appropriate antimicrobials and de-cannulated after six days of ECMO support. ECMO was an effective salvage therapy in HIV positive patient with an otherwise fatal respiratory failure due to Pneumocystis pneumonia and air leak syndrome.
Triggiani, Vincenzo; Angelo Giagulli, Vito; De Pergola, Giovanni; Licchelli, Brunella; Guastamacchia, Edoardo; Iacoviello, Massimo
2016-01-01
Subclinical hypothyroidism can be associated with the onset and progression of chronic heart failure. We undertook a careful search of the literature aiming to review the possible pathogenetic mechanisms explaining the influence of subclinical hypothyroidism on the onset and progression of chronic heart failure. Thyroid hormones can influence the expression of genes involved in calcium handling and contractile properties of myocardiocytes. Subclinical hypothyroidism, therefore, can alter both cardiovascular morphology and function leading to changes in myocardiocytes shape and structure, and to alterations of both contractile and relaxing properties, impairing systolic as well as diastolic functions. Furthermore, it can favour dyslipidemia, endothelial dysfunction and diastolic hypertension, favouring atherogenesis and coronary heart disease, possibly evolving into chronic heart failure. Beside an influence on the onset of chronic heart failure, subclinical hypothyroidism can represent a risk factor for its progression, in particular hospitalization and mortality but the mechanisms involved need to be fully elucidated. Subclinical hypothyroidism can be associated with the onset of chronic heart failure, because it can favour two frequent conditions that can evolve in heart failure: coronary heart disease and hypertension; it can also alter both cardiovascular morphology and function leading to heart failure progression in patients already affected through mechanisms still not completely understood.
Belenguer-Muncharaz, A; Albert-Rodrigo, L; Ferrandiz-Sellés, A; Cebrián-Graullera, G
2013-10-01
A comparison was made between invasive mechanical ventilation (IMV) and noninvasive positive pressure ventilation (NPPV) in haematological patients with acute respiratory failure. A retrospective observational study was made from 2001 to December 2011. A clinical-surgical intensive care unit (ICU) in a tertiary hospital. Patients with hematological malignancies suffering acute respiratory failure (ARF) and requiring mechanical ventilation in the form of either IMV or NPPV. Analysis of infection and organ failure rates, duration of mechanical ventilation and ICU and hospital stays, as well as ICU, hospital and mortality after 90 days. The same variables were analyzed in the comparison between NPPV success and failure. Forty-one patients were included, of which 35 required IMV and 6 NPPV. ICU mortality was higher in the IMV group (100% vs 37% in NPPV, P=.006). The intubation rate in NPPV was 40%. Compared with successful NPPV, failure in the NPPV group involved more complications, a longer duration of mechanical ventilation and ICU stay, and greater ICU and hospital mortality. Multivariate analysis of mortality in the NPPV group identified NPPV failure (OR 13 [95%CI 1.33-77.96], P=.008) and progression to acute respiratory distress syndrome (OR 10 [95%CI 1.95-89.22], P=.03) as prognostic factors. The use of NPPV reduced mortality compared with IMV. NPPV failure was associated with more complications. Copyright © 2012 Elsevier España, S.L. and SEMICYUC. All rights reserved.
14 CFR 29.663 - Ground resonance prevention means.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Ground resonance prevention means. 29.663... Ground resonance prevention means. (a) The reliability of the means for preventing ground resonance must... or tests that malfunction or failure of a single means will not cause ground resonance. (b) The...
14 CFR 29.663 - Ground resonance prevention means.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ground resonance prevention means. 29.663... Ground resonance prevention means. (a) The reliability of the means for preventing ground resonance must... or tests that malfunction or failure of a single means will not cause ground resonance. (b) The...
NASA Astrophysics Data System (ADS)
Adams, H. D.; Dickman, L. T.; Sevanto, S.; McDowell, N. G.; Pockman, W.; Breshears, D. D.; Huxman, T. E.
2012-12-01
Widespread increases in tree mortality are now a well-documented global phenomenon that has been linked to drought, increased temperatures, and pest/pathogen outbreaks. Since forests play an important regulatory role in planetary carbon, water, and energy budgets, further widespread tree mortality could disrupt biosphere-atmosphere feedbacks with additional effects on climate. Despite these threats, few vegetation models exist that predict drought-induced tree mortality in response to climate due, in part, to uncertainty surrounding the physiological mechanism of mortality in trees. Several mechanisms for drought mortality have been proposed, relating to tree carbohydrate balance, xylem stress, and their interaction with each other and tree pests and pathogens. Carbon starvation could occur if stomatal closure in response to drought inhibits carbon assimilation and carbohydrate resources are depleted below a critical threshold for survival. Hydraulic failure could occur if excessive xylem tension during drought causes complete and irreversible cavitation and subsequent desiccation of the canopy. Here we present results from three recent experiments with trees from the southwest US, two conducted in the glasshouse with transplanted piñon pine, and one in the field with piñon pine and juniper, where non-structural carbohydrates (NSC) and hydraulic function were assessed during drought through mortality to distinguish the relative contribution of these mechanisms to mortality. In all three experiments, piñon leaf and twig NSC declined by ~30-40% from initial values to measurement at mortality and trees experienced some hydraulic failure. In the first glasshouse study the piñon leaf NSC decline of ~30%, was driven by a ~50% decline in sugar concentration despite a 100% increase in starch concentration. Surprisingly, in this experiment NSC did not decline faster for trees that died under elevated (+4.3°C) temperatures, although starch increased earlier in these trees. In the field experiment, juniper leaf and twig NSC did not decline as mortality approached, but was lower than non-drought controls. Hydraulic failure did not occur with mortality for juniper in the field experiment. In an additional treatment in the second glasshouse experiment, well-watered piñon pines that were shaded to prevent photosynthesis experienced a ~70% decline in leaf and twig NSC at mortality, without hydraulic failure. Considering the ~70% NSC reduction in this shaded treatment as a survival threshold, piñon pine in all three drought experiments appear to have died from a combination of carbon starvation and hydraulic failure, while juniper appears to have died from carbon starvation alone. These results demonstrate that proposed tree drought mortality mechanisms are often interrelated, but can act independently. Future models of tree drought mortality should include flexibility, predicting death from mechanisms acting either independently or in combination.
Estimating a Service-Life Distribution Based on Production Counts and a Failure Database
Ryan, Kenneth J.; Hamada, Michael Scott; Vardeman, Stephen B.
2017-04-01
A manufacturer wanted to compare the service-life distributions of two similar products. These concern product lifetimes after installation (not manufacture). For each product, there were available production counts and an imperfect database providing information on failing units. In the real case, these units were expensive repairable units warrantied against repairs. Failure (of interest here) was relatively rare and driven by a different mode/mechanism than ordinary repair events (not of interest here). Approach: Data models for the service life based on a standard parametric lifetime distribution and a related limited failure population were developed. These models were used to develop expressionsmore » for the likelihood of the available data that properly accounts for information missing in the failure database. Results: A Bayesian approach was employed to obtain estimates of model parameters (with associated uncertainty) in order to investigate characteristics of the service-life distribution. Custom software was developed and is included as Supplemental Material to this case study. One part of a responsible approach to the original case was a simulation experiment used to validate the correctness of the software and the behavior of the statistical methodology before using its results in the application, and an example of such an experiment is included here. Because of confidentiality issues that prevent use of the original data, simulated data with characteristics like the manufacturer’s proprietary data are used to illustrate some aspects of our real analyses. Lastly, we also note that, although this case focuses on rare and complete product failure, the statistical methodology provided is directly applicable to more standard warranty data problems involving typically much larger warranty databases where entries are warranty claims (often for repairs) rather than reports of complete failures.« less
Estimating a Service-Life Distribution Based on Production Counts and a Failure Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan, Kenneth J.; Hamada, Michael Scott; Vardeman, Stephen B.
A manufacturer wanted to compare the service-life distributions of two similar products. These concern product lifetimes after installation (not manufacture). For each product, there were available production counts and an imperfect database providing information on failing units. In the real case, these units were expensive repairable units warrantied against repairs. Failure (of interest here) was relatively rare and driven by a different mode/mechanism than ordinary repair events (not of interest here). Approach: Data models for the service life based on a standard parametric lifetime distribution and a related limited failure population were developed. These models were used to develop expressionsmore » for the likelihood of the available data that properly accounts for information missing in the failure database. Results: A Bayesian approach was employed to obtain estimates of model parameters (with associated uncertainty) in order to investigate characteristics of the service-life distribution. Custom software was developed and is included as Supplemental Material to this case study. One part of a responsible approach to the original case was a simulation experiment used to validate the correctness of the software and the behavior of the statistical methodology before using its results in the application, and an example of such an experiment is included here. Because of confidentiality issues that prevent use of the original data, simulated data with characteristics like the manufacturer’s proprietary data are used to illustrate some aspects of our real analyses. Lastly, we also note that, although this case focuses on rare and complete product failure, the statistical methodology provided is directly applicable to more standard warranty data problems involving typically much larger warranty databases where entries are warranty claims (often for repairs) rather than reports of complete failures.« less
Mullin, Scott; Panday, Ashoutosh; Balsara, Nitash Pervez; Singh, Mohit; Eitouni, Hany Basam; Gomez, Enrique Daniel
2014-04-22
A polymer that combines high ionic conductivity with the structural properties required for Li electrode stability is useful as a solid phase electrolyte for high energy density, high cycle life batteries that do not suffer from failures due to side reactions and dendrite growth on the Li electrodes, and other potential applications. The polymer electrolyte includes a linear block copolymer having a conductive linear polymer block with a molecular weight of at least 5000 Daltons, a structural linear polymer block with an elastic modulus in excess of 1.times.10.sup.7 Pa and an ionic conductivity of at least 1.times.10.sup.-5 Scm.sup.-1. The electrolyte is made under dry conditions to achieve the noted characteristics. In another aspect, the electrolyte exhibits a conductivity drop when the temperature of electrolyte increases over a threshold temperature, thereby providing a shutoff mechanism for preventing thermal runaway in lithium battery cells.
Wilson, R.C.; Wieczorek, G.F.; Keefer, D.K.; Harp, E.L.; Tannaci, N.E.
1985-01-01
Information about the individual ground failures may be obtained from the map and the brief descriptions in table 1. The following text is a general discussion of the distribution and the mechanisms of the ground failures, followed by a discussion of the effects of wet winter conditions and of topographic amplification on the distribution and mechanisms of slope failure, and it concludes with a description of our (unsuccessful) efforts to locate any ground failures due to liquefaction. The discussion is intended not only to describe the GMDES slope failures but also to place them into the larger general context of seismically induced slope failures.
Heart failure as a general pandemic in Asia.
Shimokawa, Hiroaki; Miura, Masanobu; Nochioka, Kotaro; Sakata, Yasuhiko
2015-09-01
Heart failure (HF) is an epidemic in healthcare worldwide, including Asia. It appears that HF will become more serious in the near future, with the epidemiological transition and ageing of the population. However, in contrast to Western countries, information on HF epidemiology is still limited in Asia, particularly in South Asia. In this review, we will briefly summarize available information regarding the current and future burden of HF in Asia, which indicates the importance of both primary prevention of underlying diseases of HF and secondary prevention, including management of ischaemic HF, HF with preserved EF, and HF in the elderly. © 2015 The Authors European Journal of Heart Failure © 2015 European Society of Cardiology.
Technical complications of implant-causes and management: A comprehensive review
Gupta, Swati; Gupta, Hemant; Tandan, Amrit
2015-01-01
Given the increasing popularity of dental implants, the number of failures due to late implant fracture is also expected to increase. Hence, the scope for prevention and management needs to be emphasized. The objective of this review article is to analyze the various causes of failure of dental implants due to implant fixture/abutment screw fractures and also to enumerate the management and the preventive options for these failures, thereby aiming to help the clinicians to properly plan the implant-supported prosthesis treatment by considering the important biomechanical aspects of this type of rehabilitation. The present review emphasizes the causes and management of technical complications and not the incidence of such complications. PMID:26668445
A mathematical model for active contraction in healthy and failing myocytes and left ventricles.
Cai, Li; Wang, Yongheng; Gao, Hao; Li, Yiqiang; Luo, Xiaoyu
2017-01-01
Cardiovascular disease is one of the leading causes of death worldwide, in particular myocardial dysfunction, which may lead to heart failure eventually. Understanding the electro-mechanics of the heart will help in developing more effective clinical treatments. In this paper, we present a multi-scale electro-mechanics model of the left ventricle (LV). The Holzapfel-Ogden constitutive law was used to describe the passive myocardial response in tissue level, a modified Grandi-Pasqualini-Bers model was adopted to model calcium dynamics in individual myocytes, and the active tension was described using the Niederer-Hunter-Smith myofilament model. We first studied the electro-mechanics coupling in a single myocyte in the healthy and diseased left ventricle, and then the single cell model was embedded in a dynamic LV model to investigate the compensation mechanism of LV pump function due to myocardial dysfunction caused by abnormality in cellular calcium dynamics. The multi-scale LV model was solved using an in-house developed hybrid immersed boundary method with finite element extension. The predictions of the healthy LV model agreed well with the clinical measurements and other studies, and likewise, the results in the failing states were also consistent with clinical observations. In particular, we found that a low level of intracellular Ca2+ transient in myocytes can result in LV pump function failure even with increased myocardial contractility, decreased systolic blood pressure, and increased diastolic filling pressure, even though they will increase LV stroke volume. Our work suggested that treatments targeted at increased contractility and lowering the systolic blood pressure alone are not sufficient in preventing LV pump dysfunction, restoring a balanced physiological Ca2+ handling mechanism is necessary.
Andrade, Jason; Khairy, Paul; Dobrev, Dobromir; Nattel, Stanley
2014-04-25
Atrial fibrillation (AF) is the most common arrhythmia (estimated lifetime risk, 22%-26%). The aim of this article is to review the clinical epidemiological features of AF and to relate them to underlying mechanisms. Long-established risk factors for AF include aging, male sex, hypertension, valve disease, left ventricular dysfunction, obesity, and alcohol consumption. Emerging risk factors include prehypertension, increased pulse pressure, obstructive sleep apnea, high-level physical training, diastolic dysfunction, predisposing gene variants, hypertrophic cardiomyopathy, and congenital heart disease. Potential risk factors are coronary artery disease, kidney disease, systemic inflammation, pericardial fat, and tobacco use. AF has substantial population health consequences, including impaired quality of life, increased hospitalization rates, stroke occurrence, and increased medical costs. The pathophysiology of AF centers around 4 general types of disturbances that promote ectopic firing and reentrant mechanisms, and include the following: (1) ion channel dysfunction, (2) Ca(2+)-handling abnormalities, (3) structural remodeling, and (4) autonomic neural dysregulation. Aging, hypertension, valve disease, heart failure, myocardial infarction, obesity, smoking, diabetes mellitus, thyroid dysfunction, and endurance exercise training all cause structural remodeling. Heart failure and prior atrial infarction also cause Ca(2+)-handling abnormalities that lead to focal ectopic firing via delayed afterdepolarizations/triggered activity. Neural dysregulation is central to atrial arrhythmogenesis associated with endurance exercise training and occlusive coronary artery disease. Monogenic causes of AF typically promote the arrhythmia via ion channel dysfunction, but the mechanisms of the more common polygenic risk factors are still poorly understood and under intense investigation. Better recognition of the clinical epidemiology of AF, as well as an improved appreciation of the underlying mechanisms, is needed to develop improved methods for AF prevention and management.
Core Competencies and the Prevention of School Failure and Early School Leaving
ERIC Educational Resources Information Center
Bradshaw, Catherine P.; O'Brennan, Lindsey M.; McNeely, Clea A.
2008-01-01
There is an increasing awareness that school failure and early school leaving are processes, rather than discrete events, that often co-occur and can have lasting negative effects on children's development. Most of the literature has focused on risk factors for failure and dropout rather than on the promotion of competencies that can increase…
Modeling plaque fissuring and dissection during balloon angioplasty intervention.
Gasser, T Christian; Holzapfel, Gerhard A
2007-05-01
Balloon angioplasty intervention is traumatic to arterial tissue. Fracture mechanisms such as plaque fissuring and/or dissection occur and constitute major contributions to the lumen enlargement. However, these types of mechanically-based traumatization of arterial tissue are also contributing factors to both acute procedural complications and chronic restenosis of the treatment site. We propose physical and finite element models, which are generally useable to trace fissuring and/or dissection in atherosclerotic plaques during balloon angioplasty interventions. The arterial wall is described as an anisotropic, heterogeneous, highly deformable, nearly incompressible body, whereas tissue failure is captured by a strong discontinuity kinematics and a novel cohesive zone model. The numerical implementation is based on the partition of unity finite element method and the interface element method. The later is used to link together meshes of the different tissue components. The balloon angioplasty-based failure mechanisms are numerically studied in 3D by means of an atherosclerotic-prone human external iliac artery, with a type V lesion. Image-based 3D geometry is generated and tissue-specific material properties are considered. Numerical results show that in a primary phase the plaque fissures at both shoulders of the fibrous cap and stops at the lamina elastica interna. In a secondary phase, local dissections between the intima and the media develop at the fibrous cap location with the smallest thickness. The predicted results indicate that plaque fissuring and dissection cause localized mechanical trauma, but prevent the main portion of the stenosis from high stress, and hence from continuous tissue damage.
Virologic outcomes in early antiretroviral treatment: HPTN 052.
Eshleman, Susan H; Wilson, Ethan A; Zhang, Xinyi C; Ou, San-San; Piwowar-Manning, Estelle; Eron, Joseph J; McCauley, Marybeth; Gamble, Theresa; Gallant, Joel E; Hosseinipour, Mina C; Kumarasamy, Nagalingeswaran; Hakim, James G; Kalonga, Ben; Pilotto, Jose H; Grinsztejn, Beatriz; Godbole, Sheela V; Chotirosniramit, Nuntisa; Santos, Breno Riegel; Shava, Emily; Mills, Lisa A; Panchia, Ravindre; Mwelase, Noluthando; Mayer, Kenneth H; Chen, Ying Q; Cohen, Myron S; Fogel, Jessica M
2017-05-01
The HIV Prevention Trials Network (HPTN) 052 trial demonstrated that early antiretroviral therapy (ART) prevented 93% of HIV transmission events in serodiscordant couples. Some linked infections were observed shortly after ART initiation or after virologic failure. To evaluate factors associated with time to viral suppression and virologic failure in participants who initiated ART in HPTN 052. 1566 participants who had a viral load (VL) > 400 copies/mL at enrollment were included in the analyses. This included 832 in the early ART arm (CD4 350-550 cells/mm 3 at ART initiation) and 734 in the delayed ART arm (204 with a CD4 < 250 cells/mm 3 at ART initiation; 530 with any CD4 at ART initiation). Viral suppression was defined as two consecutive VLs ≤ 400 copies/mL after ART initiation; virologic failure was defined as two consecutive VLs > 1000 copies/mL > 24 weeks after ART initiation. Overall, 93% of participants achieved viral suppression by 12 months. The annual incidence of virologic failure was 3.6%. Virologic outcomes were similar in the two study arms. Longer time to viral suppression was associated with younger age, higher VL at ART initiation, and region (Africa vs. Asia). Virologic failure was strongly associated with younger age, lower educational level, and lack of suppression by three months; lower VL and higher CD4 at ART initiation were also associated with virologic failure. Several clinical and demographic factors were identified that were associated with longer time to viral suppression and virologic failure. Recognition of these factors may help optimize ART for HIV treatment and prevention.
Hurtado-de-Mendoza, David; Loaiza-Bonilla, Arturo; Bonilla-Reyes, Paula A; Tinoco, Gabriel; Alcorta, Rodrigo
2017-05-18
Cardio-oncology is a medical discipline that identifies, prevents, and treats the cardiovascular complications related to cancer therapy. Due to the remarkable proliferation of new cancer therapies causing cardiovascular complications, such as hypertension, heart failure, vascular complications, and cardiac arrhythmia, we provide an extensive, comprehensive revision of the most up-to-date scientific information available on the cardiovascular complications associated with the use of newer, novel chemotherapeutic agents, including their reported incidence, suggested pathophysiology, clinical manifestations, potential treatment, and prevention. The authors consider this topic to be relevant for the clinicians since cardiovascular complications associated with the administration of recently approved drugs are relatively underappreciated. The purpose of this article is to provide a state-of-the-art review of cardiovascular complications associated with the use of newer, novel chemotherapeutic agents and targeted therapies, including their reported incidence, suggested pathophysiology, clinical manifestations, potential treatment, and prevention. Ongoing efforts are needed to provide a better understanding of the frequency, mechanisms of disease, prevention, and treatment of cardiovascular complications induced by the newer, novel chemotherapeutic agents. Development of a cardio-oncology discipline is warranted in order to promote task forces aimed at the creation of oncology patient-centered guidelines for the detection, prevention, and treatment of potential cardiovascular side effects associated with newer cancer therapies.
Coming out prevention by stopper for the shrink fitted sandwiched shaft from the ceramic sleeve
NASA Astrophysics Data System (ADS)
Zhang, Guowei; Noda, Nao-Aki; Sano, Yoshikazu; Sakai, Hiromasa; Oda, Kazuhiro
2017-05-01
Ceramic roller can be used in the heating furnace conveniently because of its high temperature resistance. The roller consists of sleeve and steel shaft connected only under a small shrink fitting ratio because of the brittleness. However, the coming out of the shaft may often happen from the ceramic sleeve under repeated bending load. Therefore, how to prevent the coming out failure becomes an important issue. Based on the previous study, a two-dimensional shrink fitted structure is considered by replacing the shaft with the inner plate and by replacing the sleeve with the outer plate. Then, this research focuses on preventing the inner plate coming out from the outer plate by introducing a newly designed stopper on the outer plate. The simulation results shows that the coming out phenomenon can be prevented effectively due to the contact between the inter plate and the stopper installed on the outer plate. In order to evaluate the contact force between the inner plate and the stopper, the coming out mechanism is clarified. To prevent the coming out by stopper safely, the effects of the magnitude of repeated load and the friction coefficient upon the contact compressive force are investigated under large number of loading cycles by using 2D simulation.
Novel Prevention Strategies for Bacterial Infections in Cirrhosis
Yan, Kathleen; Garcia-Tsao, Guadalupe
2016-01-01
Introduction Bacterial infections are a serious complication of cirrhosis, as they can lead to decompensation, multiple organ failure, and/or death. Preventing infections is therefore very relevant. Because gut bacterial translocation is their main pathogenic mechanism, prevention of infections is mostly based on the use of orally administered poorly absorbed antibiotics such as norfloxacin (selective intestinal decontamination). However, antibiotic prophylaxis leads to antibiotic resistance, limiting therapy and increasing morbidity and mortality. Prevention of bacterial infections in cirrhosis should therefore move away from antibiotics. Areas Covered This review focuses on various potentially novel methods to prevent infections in cirrhosis focusing on non-antibiotic strategies. The use of probiotics, nonselective intestinal decontamination with rifaximin, prokinetics and beta-blockers or fecal microbiota transplant as means of targeting altered gut microbiota, bile acids and FXR agonists are all potential alternatives to selective intestinal decontamination. Prokinetics and beta-blockers can improve intestinal motility, while bile acids and FXR agonists help by improving the intestinal barrier. Finally, granulocyte colony stimulating factor (G-CSF) and statins are emerging therapeutic strategies that may improve immune dysfunction in cirrhosis. Expert Opinion Evidence for these strategies has been restricted to animal studies and proof-of concept studies but we expect this to change in coming years. PMID:26799197
Accelerated Thermal Cycling and Failure Mechanisms for BGA and CSP Assemblies
NASA Technical Reports Server (NTRS)
Ghaffarian, Reza
2000-01-01
This paper reviews the accelerated thermal cycling test methods that are currently used by industry to characterize the interconnect reliability of commercial-off-the-shelf (COTS) ball grid array (BGA) and chip scale package (CSP) assemblies. Acceleration induced failure mechanisms varied from conventional surface mount (SM) failures for CSPs. Examples of unrealistic life projections for other CSPs are also presented. The cumulative cycles to failure for ceramic BGA assemblies performed under different conditions, including plots of their two Weibull parameters, are presented. The results are for cycles in the range of -30 C to 100 C, -55 C to 100 C, and -55 C to 125 C. Failure mechanisms as well as cycles to failure for thermal shock and thermal cycling conditions in the range of -55 C to 125 C were compared. Projection to other temperature cycling ranges using a modified Coffin-Manson relationship is also presented.
Mechanical failure probability of glasses in Earth orbit
NASA Technical Reports Server (NTRS)
Kinser, Donald L.; Wiedlocher, David E.
1992-01-01
Results of five years of earth-orbital exposure on mechanical properties of glasses indicate that radiation effects on mechanical properties of glasses, for the glasses examined, are less than the probable error of measurement. During the 5 year exposure, seven micrometeorite or space debris impacts occurred on the samples examined. These impacts were located in locations which were not subjected to effective mechanical testing, hence limited information on their influence upon mechanical strength was obtained. Combination of these results with micrometeorite and space debris impact frequency obtained by other experiments permits estimates of the failure probability of glasses exposed to mechanical loading under earth-orbit conditions. This probabilistic failure prediction is described and illustrated with examples.
Mechanical Evaluation of Unobstructing Magnetic Microactuators for Implantable Ventricular Catheters
Lee, Hyowon; Kolahi, Kameran; Bergsneider, Marvin; Judy, Jack W.
2017-01-01
Here, we report on the development and evaluation of novel unobstructing magnetic microactuators for maintaining the patency of implantable ventricular catheters used in hydrocephalus application. The treatment of hydrocephalus requires chronic implantation of a shunt system to divert excess cerebrospinal fluid from the brain. These shunt systems suffer from a high failure rate (>40%) within the first year of implantation, often due to biological accumulation. Previously, we have shown that magnetic microactuators can be used to remove biological blockage. The new cantilever-based magnetic microactuator presented in this paper improves upon the previous torsional design using a bimorph to induce a postrelease out-of-plane deflection that will prevent the device from occluding the pore at rest. The mechanical evaluations (i.e., postrelease deflection, static and dynamic responses) of fabricated devices are reported and compared with theoretical values. PMID:29151776
[Non-invasive mechanical ventilation in postoperative patients. A clinical review].
Esquinas, A M; Jover, J L; Úbeda, A; Belda, F J
2015-11-01
Non-invasive ventilation (NIV) is a method of ventilatory support that is increasing in importance day by day in the management of postoperative respiratory failure. Its role in the prevention and treatment of atelectasis is particularly important in the in the period after thoracic and abdominal surgeries. Similarly, in the transplanted patient, NIV can shorten the time of invasive mechanical ventilation, reducing the risk of infectious complications in these high-risk patients. It has been performed A systematic review of the literature has been performed, including examining the technical, clinical experiences and recommendations concerning the application of NIV in the postoperative period. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
A production parylene coating process for hybrid microcircuits
NASA Technical Reports Server (NTRS)
Kale, V. S.; Riley, T. J.
1977-01-01
The real impetus for developing a production parylene coating process for internal hybrid passivation came as a result of the possibility of loose conductive particles in hybrid microelectronic circuits, causing intermittent and sometimes permanent failures. Because of the excellent mechanical properties of parylene, it is capable of securing the loose particles in place and prevent such failures. The process of coating described consists of (1) vaporizing the initial charge, which is in the form of a dimer; (2) conversion of the dimer into a reactive monomer; and (3) deposition and subsequent polymerization of the monomer in the deposition chamber which forms a uniform parylene film over all the cold surfaces in contact. Experimental results are discussed in terms of wire bond reliability, resistor drift, high-temperature storage characteristics of parylene, and coating acceptance standards. It is concluded that internal cavities of microelectronic circuits can be successfully coated with parylene provided appropriate tooling is used to protect external leads from the parylene monomer.
Pardinas, Miguel; Mendirichaga, Rodrigo; Budhrani, Gaurav; Garg, Rajan; Rosario, Luis; Rico, Rene; Panos, Anthony; Baier, Horst; Krick, Stefanie
2017-01-01
A 32-year-old man presented with a 10-day history of fever, chills, nausea, vomiting, myalgia, nonproductive cough, and worsening dyspnea after freshwater swimming in the Caribbean 1 week prior to presentation. Shortly after arrival at the hospital, the patient developed severe respiratory distress with massive hemoptysis. Based on serologic workup, he was diagnosed with leptospirosis pulmonary hemorrhage syndrome leading to diffuse alveolar hemorrhage, severe hypoxemic respiratory failure, and multiorgan failure. He received appropriate antibiotic coverage along with hemodynamic support with norepinephrine and vasopressin, mechanical ventilation, and renal replacement therapy in an intensive care unit. Introduction of extracorporeal membrane oxygenation was initiated to provide lung-protective ventilation supporting the recovery of his pulmonary function. Aminocaproic acid was used to stop and prevent further alveolar hemorrhage. He fully recovered thereafter; however, it is uncertain whether it was the use of aminocaproic acid that led to the resolution of his disease.
Pardinas, Miguel; Mendirichaga, Rodrigo; Budhrani, Gaurav; Garg, Rajan; Rosario, Luis; Rico, Rene; Panos, Anthony; Baier, Horst; Krick, Stefanie
2017-01-01
A 32-year-old man presented with a 10-day history of fever, chills, nausea, vomiting, myalgia, nonproductive cough, and worsening dyspnea after freshwater swimming in the Caribbean 1 week prior to presentation. Shortly after arrival at the hospital, the patient developed severe respiratory distress with massive hemoptysis. Based on serologic workup, he was diagnosed with leptospirosis pulmonary hemorrhage syndrome leading to diffuse alveolar hemorrhage, severe hypoxemic respiratory failure, and multiorgan failure. He received appropriate antibiotic coverage along with hemodynamic support with norepinephrine and vasopressin, mechanical ventilation, and renal replacement therapy in an intensive care unit. Introduction of extracorporeal membrane oxygenation was initiated to provide lung-protective ventilation supporting the recovery of his pulmonary function. Aminocaproic acid was used to stop and prevent further alveolar hemorrhage. He fully recovered thereafter; however, it is uncertain whether it was the use of aminocaproic acid that led to the resolution of his disease. PMID:28469503
International Space Station Powered Bolt Nut Anomaly and Failure Analysis Summary
NASA Technical Reports Server (NTRS)
Sievers, Daniel E.; Warden, Harry K.
2010-01-01
A key mechanism used in the on-orbit assembly of the International Space Station (ISS) pressurized elements is the Common Berthing Mechanism. The mechanism that effects the structural connection of the Common Berthing Mechanism halves is the Powered Bolt Assembly. There are sixteen Powered Bolt Assemblies per Common Berthing Mechanism. The Common Berthing Mechanism has a bolt which engages a self aligning Powered Bolt Nut (PBN) on the mating interface (Figure 1). The Powered Bolt Assemblies are preloaded to approximately 84.5 kN (19000 lb) prior to pressurization of the CBM. The PBNs mentioned below, manufactured in 2009, will be used on ISS future missions. An on orbit functional failure of this hardware would be unacceptable and in some instances catastrophic due to the failure of modules to mate and seal the atmosphere, risking loss of crew and ISS functions. The manufacturing processes that create the PBNs need to be strictly controlled. Functional (torque vs. tension) acceptance test failures will be the result of processes not being strictly followed. Without the proper knowledge of thread tolerances, fabrication techniques, and dry film lubricant application processes, PBNs will be, and have been manufactured improperly. The knowledge gained from acceptance test failures and the resolution of those failures, thread fabrication techniques and thread dry film lubrication processes can be applied to many aerospace mechanisms to enhance their performance. Test data and manufactured PBN thread geometry will be discussed for both failed and successfully accepted PBNs.
Pokorney, Sean D; Greenfield, Ruth Ann; Atwater, Brett D; Daubert, James P; Piccini, Jonathan P
2014-12-01
Battery failure is an uncommon complication of implantable cardioverter-defibrillators (ICDs), but unanticipated battery depletion can have life-threatening consequences. The purpose of this study was to describe the prevalence of a novel mechanism of battery failure in St. Jude Medical Fortify and Unify ICDs. Cases of premature Fortify battery failure from a single center are reported. A search (January 1, 2010 through November 30, 2013) for Fortify and Unify premature batter failure was conducted of the Food and Drug Administration's Manufacturer and User Facility Device Experience Database (MAUDE). These findings were supplemented with information provided by St. Jude Medical. Premature battery failure for 2 Fortify ICDs in our practice were attributed to the presence of lithium clusters near the cathode, causing a short circuit and high current drain. The prevalence of this mechanism of premature battery failure was 0.6% in our practice. A MAUDE search identified 39 cases of Fortify (30) and Unify (9) premature battery depletion confirmed by the manufacturer, representing a 0.03% prevalence. Four additional Fortify and 2 Unify cases were identified in MAUDE as suspected premature battery depletion, but in these cases the pulse generator was not returned to the manufacturer for evaluation. St. Jude Medical identified 10 cases of premature battery failure due to lithium clusters in Fortify devices (9) and Unify devices (1), representing a 0.004% prevalence. The deposition of lithium clusters near the cathode is a novel mechanism of premature battery failure. The prevalence of this problem is unknown. Providers should be aware of this mechanism for patient management. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Development of the Orion Crew-Service Module Umbilical Retention and Release Mechanism
NASA Technical Reports Server (NTRS)
Delap, Damon C.; Glidden, Joel Micah; Lamoreaux, Christopher
2013-01-01
The Orion CSM umbilical retention and release mechanism supports and protects all of the cross-module commodities between the spacecrafts crew and service modules. These commodities include explosive transfer lines, wiring for power and data, and flexible hoses for ground purge and life support systems. The mechanism employs a single separation interface which is retained with pyrotechnically actuated separation bolts and supports roughly two dozen electrical and fluid connectors. When module separation is commanded, either for nominal on-orbit CONOPS or in the event of an abort, the mechanism must release the separation interface and sever all commodity connections within milliseconds of command receipt. There are a number of unique and novel aspects of the design solution developed by the Orion mechanisms team. The design is highly modular and can easily be adapted to other vehiclesmodules and alternate commodity sets. It will be flight tested during Orions Exploration Flight Test 1 (EFT-1) in 2014, and the Orion team anticipates reuse of the design for all future missions. The design packages fluid, electrical, and ordnance disconnects in a single separation interface. It supports abort separations even in cases where aerodynamic loading prevents the deployment of the umbilical arm. Unlike the Apollo CSM umbilical which was a destructive separation device, the Orion design is resettable and flight units can be tested for separation performance prior to flight.Initial development testing of the mechanisms separation interface resulted in binding failures due to connector misalignments. The separation interface was redesigned with a robust linear guide system, and the connector separation and boom deployment were separated into two discretely sequenced events. These changes addressed the root cause of the binding failure by providing better control of connector alignment. The new design was tuned and validated analytically via Monte Carlo simulation. The analytical validation was followed by a repeat of the initial test suite plus test cases at thermal extremes and test cases with imposed mechanical failures demonstrating fault tolerance. The mechanism was then exposed to the qualification vibration environment. Finally, separation testing was performed at full speed with live ordnance.All tests of the redesigned mechanism resulted in successful separation of the umbilical interface with adequate force margins and timing. The test data showed good agreement with the predictions of the Monte Carlo simulation. The simulation proved invaluable due to the number of variables affecting the separation and the uncertainty associated with each. The simulation allowed for rapid assessment of numerous trades and contingency scenarios, and can be easily reconfigured for varying commodity sets and connector layouts.
2017-03-30
Composite Damage and Failure Analysis Combining Synergistic Damage Mechanics and Peridynamics 5b. GRANT NUMBER NOOO 14-16-1-21 73 5c. PROGRAM...ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Texas A&M Engineering Experiment Station (TEES) 400 Harvey Mitchell Parkway, Suite 300 M160 1473 I...Failure Analysis Combining Synergistic Damage Mechanics and Peridynamics Award Number N00014-16-1-2173 DOD-NAVY- Office of Naval Research PI: Ramesh
Hattori, Yuichi; Hattori, Kohshi; Suzuki, Tokiko; Matsuda, Naoyuki
2017-09-01
Sepsis is one of the most common reasons for critically ill patients to be admitted to an intensive care unit and, despite advances in overall medical care, it represents a major clinical problem and remains the leading cause of death in the critically ill patient population. Although sepsis has been defined as a systemic inflammatory syndrome, in which there is an identifiable focus of infection, clinical trials aimed at anti-inflammatory therapeutic approaches have largely failed to identify an effective therapeutic target to improve clinical outcomes in sepsis. Very recently, the third international consensus definitions have been advocated for sepsis and septic shock. Thus, sepsis is now defined as life-threatening organ dysfunction due to a dysregulated host response to infection. A better understanding of the molecular mechanisms involved in the pathogenesis of sepsis and its resultant organ failure has been sought, and the development of therapies targeted at preventing or limiting molecular events associated with the progress of fatal organ failure, hence leading to improvement of outcomes, is urgently needed. This review article provides an overview of possible pathogenic mechanisms underlying the development of multiple organ dysfunction in sepsis and discusses pharmacological agents regarded as promising in treatment of this disorder. Copyright © 2017 Elsevier Inc. All rights reserved.
El-Agamy, Dina S; Makled, Mirhan N; Gamil, Nareman M
2014-06-01
Fulminant hepatic failure (FHF) is a life-threatening syndrome characterized by massive hepatic necrosis and high mortality. There is no effective therapy for the disease other than liver transplantation. This study aimed to investigate the effect of agmatine, inducible nitric oxide synthase (iNOS) inhibitor, on D-galactosamine and lipopolysaccharide (GalN/LPS)-induced FHF in mice and explore its possible mechanism(s). Male Swiss albino mice were injected with a single dose agmatine (14 mg/kg, IP) 8 h prior to challenge with a single intraperitoneal injection of both GalN (800 mg/kg) and LPS (50 μg/kg). Agmatine significantly attenuated all GalN/LPS-induced biochemical and pathological changes in liver. It prevented the increase of serum transaminases and alkaline phosphatase (ALP). In addition, agmatine markedly attenuated GalN/LPS-induced necrosis and inflammation. Agmatine significantly reduced oxidative stress and enhanced antioxidant enzymes. Importantly, agmatine decreased total nitric oxide (NO) and pro-inflammatory cytokine, tumor necrosis factor-alpha (TNF-α). These findings reveal that agmatine has hepatoprotective effects against GalN/LPS-induced FHF in mice that may be related to its ability to suppress oxidative stress, NO synthesis and TNF-α production. Therefore, agmatine may serve as a novel therapeutic strategy for hepatic inflammatory diseases.
Rathore, Farooq A; Ahmad, Faria; Zahoor, Muhammad Umar U
2016-10-03
Non-invasive ventilation (NIV) is used in patients with respiratory failure, sleep apnoea, and dyspnoea related to pulmonary oedema. NIV is provided through a facial mask. Many complications of NIV facial masks have been reported, including the breakdown of facial skin. We report a case of an elderly male admitted with multiple co-morbidities. The facial mask was applied continuously for NIV, without any relief or formal monitoring of the underlying skin. It resulted in a Grade II pressure ulcer. We discuss the possible mechanism and offer advice for prevention of such device-related pressure ulcers.
NASA Astrophysics Data System (ADS)
Li, N.; Cheng, Y. M.
2015-01-01
Landslide is a major disaster resulting in considerable loss of human lives and property damages in hilly terrain in Hong Kong, China and many other countries. The factor of safety and the critical slip surface for slope stabilization are the main considerations for slope stability analysis in the past, while the detailed post-failure conditions of the slopes have not been considered in sufficient detail. There is however increasing interest in the consequences after the initiation of failure that includes the development and propagation of the failure surfaces, the amount of failed mass and runoff and the affected region. To assess the development of slope failure in more detail and to consider the potential danger of slopes after failure has initiated, the slope stability problem under external surcharge is analyzed by the distinct element method (DEM) and a laboratory model test in the present research. A more refined study about the development of failure, microcosmic failure mechanisms and the post-failure mechanisms of slopes will be carried out. The numerical modeling method and the various findings from the present work can provide an alternate method of analysis of slope failure, which can give additional information not available from the classical methods of analysis.
Laboratory and 3-D-distinct element analysis of failure mechanism of slope under external surcharge
NASA Astrophysics Data System (ADS)
Li, N.; Cheng, Y. M.
2014-09-01
Landslide is a major disaster resulting in considerable loss of human lives and property damages in hilly terrain in Hong Kong, China and many other countries. The factor of safety and the critical slip surface for slope stabilization are the main considerations for slope stability analysis in the past, while the detailed post-failure conditions of the slopes have not been considered in sufficient details. There are however increasing interest on the consequences after the initiation of failure which includes the development and propagation of the failure surfaces, the amount of failed mass and runoff and the affected region. To assess the development of slope failure in more details and to consider the potential danger of slopes after failure has initiated, the slope stability problem under external surcharge is analyzed by the distinct element method (DEM) and laboratory model test in the present research. A more refined study about the development of failure, microcosmic failure mechanism and the post-failure mechanism of slope will be carried out. The numerical modeling method and the various findings from the present work can provide an alternate method of analysis of slope failure which can give additional information not available from the classical methods of analysis.
The failure of earthquake failure models
Gomberg, J.
2001-01-01
In this study I show that simple heuristic models and numerical calculations suggest that an entire class of commonly invoked models of earthquake failure processes cannot explain triggering of seismicity by transient or "dynamic" stress changes, such as stress changes associated with passing seismic waves. The models of this class have the common feature that the physical property characterizing failure increases at an accelerating rate when a fault is loaded (stressed) at a constant rate. Examples include models that invoke rate state friction or subcritical crack growth, in which the properties characterizing failure are slip or crack length, respectively. Failure occurs when the rate at which these grow accelerates to values exceeding some critical threshold. These accelerating failure models do not predict the finite durations of dynamically triggered earthquake sequences (e.g., at aftershock or remote distances). Some of the failure models belonging to this class have been used to explain static stress triggering of aftershocks. This may imply that the physical processes underlying dynamic triggering differs or that currently applied models of static triggering require modification. If the former is the case, we might appeal to physical mechanisms relying on oscillatory deformations such as compaction of saturated fault gouge leading to pore pressure increase, or cyclic fatigue. However, if dynamic and static triggering mechanisms differ, one still needs to ask why static triggering models that neglect these dynamic mechanisms appear to explain many observations. If the static and dynamic triggering mechanisms are the same, perhaps assumptions about accelerating failure and/or that triggering advances the failure times of a population of inevitable earthquakes are incorrect.
Two Key Strategies for Teaching Prevention: Specialized Course and Infusion
ERIC Educational Resources Information Center
Conyne, Robert K.; Newmeyer, Mark D.; Kenny, Maureen; Romano, John L.; Matthews, Constance R.
2008-01-01
Prevention is taught only rarely in counseling and counseling psychology curricula. Failure to teach it suggests that graduates may be less likely to conduct prevention. In this article, we describe two key strategies for addressing this problem, where prevention is being taught through (a) required courses, and (b) infusion within existing…
Renal function monitoring in heart failure – what is the optimal frequency? A narrative review
Wright, David; Devonald, Mark Alexander John; Pirmohamed, Munir
2017-01-01
The second most common cause of hospitalization due to adverse drug reactions in the UK is renal dysfunction due to diuretics, particularly in patients with heart failure, where diuretic therapy is a mainstay of treatment regimens. Therefore, the optimal frequency for monitoring renal function in these patients is an important consideration for preventing renal failure and hospitalization. This review looks at the current evidence for optimal monitoring practices of renal function in patients with heart failure according to national and international guidelines on the management of heart failure (AHA/NICE/ESC/SIGN). Current guidance of renal function monitoring is in large part based on expert opinion, with a lack of clinical studies that have specifically evaluated the optimal frequency of renal function monitoring in patients with heart failure. Furthermore, there is variability between guidelines, and recommendations are typically nonspecific. Safer prescribing of diuretics in combination with other antiheart failure treatments requires better evidence for frequency of renal function monitoring. We suggest developing more personalized monitoring rather than from the current medication‐based guidance. Such flexible clinical guidelines could be implemented using intelligent clinical decision support systems. Personalized renal function monitoring would be more effective in preventing renal decline, rather than reacting to it. PMID:28901643
Risk, Issues and Lessons Learned: Maximizing Risk Management in the DoD Ground Domain
2011-10-01
Carnegie Mellon University “Risk Management Overview for TACOM” Benefits of Risk Management include: • Risk is a proactive approach - preventing... Chili (no beans) 13 • Hot dog sub-assy Unclassified How does the FMEA work? Execute the analysis and discover the potential failures and effects...34 - --· . -· A c u i.rition Benefits of FMEAs • Prevent major risks, reduce failures, minimize cost and reduce development time - Do it right the first time
Missile and Space Systems Reliability versus Cost Trade-Off Study
1983-01-01
F00-1C09 Robert C. Schneider F00-1C09 V . PERFORMING ORGANIZATION NAME AM0 ADDRESS 16 PRGRAM ELEMENT. PROJECT. TASK BoeingAerosace CmpAnyA CA WORK UNIT...reliability problems, which has the - real bearing on program effectiveness. A well planned and funded reliability effort can prevent or ferret out...failure analysis, and the in- corporation and verification of design corrections to prevent recurrence of failures. 302.2.2 A TMJ test plan shall be
Balashova, Olga A.; Visina, Olesya
2017-01-01
Folate supplementation prevents up to 70% of neural tube defects (NTDs), which result from a failure of neural tube closure during embryogenesis. The elucidation of the mechanisms underlying folate action has been challenging. This study introduces Xenopus laevis as a model to determine the cellular and molecular mechanisms involved in folate action during neural tube formation. We show that knockdown of folate receptor 1 (Folr1; also known as FRα) impairs neural tube formation and leads to NTDs. Folr1 knockdown in neural plate cells only is necessary and sufficient to induce NTDs. Folr1-deficient neural plate cells fail to constrict, resulting in widening of the neural plate midline and defective neural tube closure. Pharmacological inhibition of folate action by methotrexate during neurulation induces NTDs by inhibiting folate interaction with its uptake systems. Our findings support a model in which the folate receptor interacts with cell adhesion molecules, thus regulating the apical cell membrane remodeling and cytoskeletal dynamics necessary for neural plate folding. Further studies in this organism could unveil novel cellular and molecular events mediated by folate and lead to new ways of preventing NTDs. PMID:28255006
Vogel, Nicolas; Belisle, Rebecca A.; Hatton, Benjamin; ...
2013-07-31
A transparent coating that repels a wide variety of liquids, prevents staining, is capable of self-repair and is robust towards mechanical damage can have a broad technological impact, from solar cell coatings to self-cleaning optical devices. Here we employ colloidal templating to design transparent, nanoporous surface structures. A lubricant can be firmly locked into the structures and, owing to its fluidic nature, forms a defect-free, self-healing interface that eliminates the pinning of a second liquid applied to its surface, leading to efficient liquid repellency, prevention of adsorption of liquid-borne contaminants, and reduction of ice adhesion strength. We further show howmore » this method can be applied to locally pattern the repellent character of the substrate, thus opening opportunities to spatially confine any simple or complex fluids. The coating is highly defect-tolerant due to its interconnected, honeycomb wall structure, and repellency prevails after the application of strong shear forces and mechanical damage. The regularity of the coating allows us to understand and predict the stability or failure of repellency as a function of lubricant layer thickness and defect distribution based on a simple geometric model.« less
Darmochwal-Kolarz, Dorota; Kolarz, Bogdan; Korzeniewski, Michal; Kimber-Trojnar, Zaneta; Patro-Malysza, Jolanta; Mierzynski, Radzisław; Przegalinska-Kałamucka, Monika; Oleszczuk, Jan
Pre-eclampsia appears to be the main cause for the maternal and fetal morbidity and mortality. Pregnant women with pre-eclampsia are more likely to be threatened with conditions which potentially may be lethal, such as: disseminated intravascular coagulation, cerebral hemorrhage, liver and renal failure. Pregnancy complicated with pre-eclampsia is also associated with a greater risk for iatrogenic prematurity, intrauterine growth retardation, premature abruption of placenta, and even intrauterine fetal death. In the majority of cases the reasons for arterial hypertension among pregnant women remain obscure. For the past decades, there were many abortive attempts in the use of some microelements, vitamins or specific diets, such as polyunsaturated fatty acids, for the prophylaxis of pre-eclampsia. Recently, it has been shown that a prevention of pre-eclampsia with the use of a lowmolecular- weight heparins (LMWHs) and acetylsalicylic acid (ASA) could considerably reduce the frequency of preeclampsia. In this review, we present the studies concerning the applications of LMWHs and aspirin in the prophylaxis of pre-eclampsia and some important data about the mechanisms of anti-inflammatory actions of LMWHs and ASA.
Nephropathy in dietary hyperoxaluria: A potentially preventable acute or chronic kidney disease
Glew, Robert H; Sun, Yijuan; Horowitz, Bruce L; Konstantinov, Konstantin N; Barry, Marc; Fair, Joanna R; Massie, Larry; Tzamaloukas, Antonios H
2014-01-01
Hyperoxaluria can cause not only nephrolithiasis and nephrocalcinosis, but also renal parenchymal disease histologically characterized by deposition of calcium oxalate crystals throughout the renal parenchyma, profound tubular damage and interstitial inflammation and fibrosis. Hyperoxaluric nephropathy presents clinically as acute or chronic renal failure that may progress to end-stage renal disease (ESRD). This sequence of events, well recognized in the past in primary and enteric hyperoxalurias, has also been documented in a few cases of dietary hyperoxaluria. Estimates of oxalate intake in patients with chronic dietary hyperoxaluria who developed chronic kidney disease or ESRD were comparable to the reported average oxalate content of the diets of certain populations worldwide, thus raising the question whether dietary hyperoxaluria is a primary cause of ESRD in these regions. Studies addressing this question have the potential of improving population health and should be undertaken, alongside ongoing studies which are yielding fresh insights into the mechanisms of intestinal absorption and renal excretion of oxalate, and into the mechanisms of development of oxalate-induced renal parenchymal disease. Novel preventive and therapeutic strategies for treating all types of hyperoxaluria are expected to develop from these studies. PMID:25374807
Defect induced plasticity and failure mechanism of boron nitride nanotubes under tension
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anoop Krishnan, N. M., E-mail: anoopnm@civil.iisc.ernet.in; Ghosh, Debraj
2014-07-28
The effects of Stone-Wales (SW) and vacancy defects on the failure behavior of boron nitride nanotubes (BNNTs) under tension are investigated using molecular dynamics simulations. The Tersoff-Brenner potential is used to model the atomic interaction and the temperature is maintained close to 300 K. The effect of a SW defect is studied by determining the failure strength and failure mechanism of nanotubes with different radii. In the case of a vacancy defect, the effect of an N-vacancy and a B-vacancy is studied separately. Nanotubes with different chiralities but similar diameter is considered first to evaluate the chirality dependence. The variation ofmore » failure strength with the radius is then studied by considering nanotubes of different diameters but same chirality. It is observed that the armchair BNNTs are extremely sensitive to defects, whereas the zigzag configurations are the least sensitive. In the case of pristine BNNTs, both armchair and zigzag nanotubes undergo brittle failure, whereas in the case of defective BNNTs, only the zigzag ones undergo brittle failure. An interesting defect induced plastic behavior is observed in defective armchair BNNTs. For this nanotube, the presence of a defect triggers mechanical relaxation by bond breaking along the closest zigzag helical path, with the defect as the nucleus. This mechanism results in a plastic failure.« less
Developments in rabies vaccines.
Hicks, D J; Fooks, A R; Johnson, N
2012-09-01
The development of vaccines that prevent rabies has a long and distinguished history, with the earliest preceding modern understanding of viruses and the mechanisms of immune protection against disease. The correct application of inactivated tissue culture-derived vaccines is highly effective at preventing the development of rabies, and very few failures are recorded. Furthermore, oral and parenteral vaccination is possible for wildlife, companion animals and livestock, again using inactivated tissue culture-derived virus. However, rabies remains endemic in many regions of the world and causes thousands of human deaths annually. There also remain no means of prophylaxis for rabies once the virus enters the central nervous system (CNS). One reason for this is the poor immune response within the CNS to infection with rabies virus (RABV). New approaches to vaccination using modified rabies viruses that express components of the innate immune system are being applied to this problem. Preliminary reports suggest that direct inoculation of such viruses could trigger an effective anti-viral response and prevent a fatal outcome from RABV infection. © 2012 Crown copyright. Clinical and Experimental Immunology © 2012 British Society for Immunology.
One-Dimensional Simulations for Spall in Metals with Intra- and Inter-grain failure models
NASA Astrophysics Data System (ADS)
Ferri, Brian; Dwivedi, Sunil; McDowell, David
2017-06-01
The objective of the present work is to model spall failure in metals with coupled effect of intra-grain and inter-grain failure mechanisms. The two mechanisms are modeled by a void nucleation, growth, and coalescence (VNGC) model and contact-cohesive model respectively. Both models were implemented in a 1-D code to simulate spall in 6061-T6 aluminum at two impact velocities. The parameters of the VNGC model without inter-grain failure and parameters of the cohesive model without intra-grain failure were first determined to obtain pull-back velocity profiles in agreement with experimental data. With the same impact velocities, the same sets of parameters did not predict the velocity profiles when both mechanisms were simultaneously activated. A sensitivity study was performed to predict spall under combined mechanisms by varying critical stress in the VNGC model and maximum traction in the cohesive model. The study provided possible sets of the two parameters leading to spall. Results will be presented comparing the predicted velocity profile with experimental data using one such set of parameters for the combined intra-grain and inter-grain failures during spall. Work supported by HDTRA1-12-1-0004 gran and by the School of Mechanical Engineering GTA.
ERIC Educational Resources Information Center
Newcomb, Michael D.; Abbott, Robert D.; Catalano, Richard F.; Hawkins, J. David; Battin-Pearson, Sara; Hill, Karl
2002-01-01
Understanding and preventing high school failure is a national priority. Structural strain and general deviance theories attempt to explain late high school failure. The authors tested the hypotheses that general (vs. specific) deviance and academic competence mediate the relationships between structural strain factors (gender, ethnicity, and…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-09
... was prompted by a report of an uncontained failure of a first stage turbine disk that had a metallurgical defect. We are proposing this AD to prevent uncontained failure of the first stage turbine disk... corrected, could result in uncontained failure of the first stage turbine disks made from these billets and...
Thorneloe, Kevin S; Cheung, Mui; Bao, Weike; Alsaid, Hasan; Lenhard, Stephen; Jian, Ming-Yuan; Costell, Melissa; Maniscalco-Hauk, Kristeen; Krawiec, John A; Olzinski, Alan; Gordon, Earl; Lozinskaya, Irina; Elefante, Lou; Qin, Pu; Matasic, Daniel S; James, Chris; Tunstead, James; Donovan, Brian; Kallal, Lorena; Waszkiewicz, Anna; Vaidya, Kalindi; Davenport, Elizabeth A; Larkin, Jonathan; Burgert, Mark; Casillas, Linda N; Marquis, Robert W; Ye, Guosen; Eidam, Hilary S; Goodman, Krista B; Toomey, John R; Roethke, Theresa J; Jucker, Beat M; Schnackenberg, Christine G; Townsley, Mary I; Lepore, John J; Willette, Robert N
2012-11-07
Pulmonary edema resulting from high pulmonary venous pressure (PVP) is a major cause of morbidity and mortality in heart failure (HF) patients, but current treatment options demonstrate substantial limitations. Recent evidence from rodent lungs suggests that PVP-induced edema is driven by activation of pulmonary capillary endothelial transient receptor potential vanilloid 4 (TRPV4) channels. To examine the therapeutic potential of this mechanism, we evaluated TRPV4 expression in human congestive HF lungs and developed small-molecule TRPV4 channel blockers for testing in animal models of HF. TRPV4 immunolabeling of human lung sections demonstrated expression of TRPV4 in the pulmonary vasculature that was enhanced in sections from HF patients compared to controls. GSK2193874 was identified as a selective, orally active TRPV4 blocker that inhibits Ca(2+) influx through recombinant TRPV4 channels and native endothelial TRPV4 currents. In isolated rodent and canine lungs, TRPV4 blockade prevented the increased vascular permeability and resultant pulmonary edema associated with elevated PVP. Furthermore, in both acute and chronic HF models, GSK2193874 pretreatment inhibited the formation of pulmonary edema and enhanced arterial oxygenation. Finally, GSK2193874 treatment resolved pulmonary edema already established by myocardial infarction in mice. These findings identify a crucial role for TRPV4 in the formation of HF-induced pulmonary edema and suggest that TRPV4 blockade is a potential therapeutic strategy for HF patients.
Leung, K-S.; Li, Y-H.; Liu, Y.; Wang, H.; Tam, K-F.; Chow, D.H.K.; Wan, Y.; Ling, S.; Dai, Z.; Qin, L.; Cheung, W-H.
2015-01-01
Objectives: To investigate deterioration of musculoskeletal system due to prolonged disuse and the potential of daily short-duration weight-bearing as countermeasures. Methods: Twenty-four adult male Sprague-Dawley rats were divided into Control Group (CG, no intervention), Tail-suspension Group (TG, tail-suspension without treatment), and Weight-Bearing Group (WBG, tail-suspension with 20 min/day, 5 days/week body weight loading). After four weeks of treatment, femur and tibia, soleus and extensor digitorum longus were evaluated for bone and muscle quality respectively. Tensile properties of bone-tendon insertion (BTI) were evaluated using patella-patellar tendon complex. Results: Disuse induced deterioration on bone, muscle, and BTI after four weeks. Compared with CG, TG and WBG showed significant decrease in bone mineral density (BMD) of trabecular bone in distal femur (4.3-15.2%), muscle mass (31.3-52.3%), muscle cross-sectional area (29.1-35%), and failure strength of BTI (23.9-29.4%). Tensile test showed that the failure mode was avulsion of bone at the BTI. No significant difference was detected between TG and WBG for all assessments on bone, muscle, and BTI. Conclusions: Disuse caused deterioration of bone, muscle, and BTI while daily short-duration of weight-bearing did not prevent this deterioration. Mechanical stimulation with higher intensity and longer duration may be necessary to prevent musculoskeletal deterioration resulted from prolonged disuse. PMID:26032214
2006-09-01
compression, including real-time cinematography of failure under dynamic compression, was evaluated. The results (figure 10) clearly show that the failure... art of simulations of dynamic failure and damage mechanisms. An explicit dynamic parallel code has been developed to track damage mechanisms in the
40 CFR 68.67 - Process hazard analysis.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.67 Process hazard analysis. (a... instrumentation with alarms, and detection hardware such as hydrocarbon sensors.); (4) Consequences of failure of...
40 CFR 68.67 - Process hazard analysis.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.67 Process hazard analysis. (a... instrumentation with alarms, and detection hardware such as hydrocarbon sensors.); (4) Consequences of failure of...
Failure mechanisms in energy-absorbing composite structures
NASA Astrophysics Data System (ADS)
Johnson, Alastair F.; David, Matthew
2010-11-01
Quasi-static tests are described for determination of the energy-absorption properties of composite crash energy-absorbing segment elements under axial loads. Detailed computer tomography scans of failed specimens were used to identify local compression crush failure mechanisms at the crush front. These mechanisms are important for selecting composite materials for energy-absorbing structures, such as helicopter and aircraft sub-floors. Finite element models of the failure processes are described that could be the basis for materials selection and future design procedures for crashworthy structures.
NASA Technical Reports Server (NTRS)
Tung, P. P. (Editor); Agrawal, S. P.; Kumar, A.; Katcher, M.
1981-01-01
Papers are presented on the application of fracture mechanics to spacecraft design, fracture control applications on the Space Shuttle reaction control thrusters, and an assessment of fatigue crack growth rate relationships for metallic airframe materials. Also considered are fracture mechanisms and microstructural relationships in Ni-base alloy systems, the use of surface deformation markings to determine crack propagation directions, case histories of metallurgical failures in the electronics industry, and a failure analysis of silica phenolic nozzle liners.
Preventing home health nursing assistant back and shoulder injuries.
Leff, E W; Hagenbach, G L; Marn, K K
2000-10-01
Franklin County Home Health Agency (St Albans, Vermont) undertook a performance improvement project in 1996 to reduce employee injuries. A review of recent injuries led to the prevention of licensed nursing assistants' (LNAs') back and shoulder injuries as the first priority. Root causes of injuries were agency communication, employee training, patient home environment, nursing assistant body mechanics, and failure to use safety measures. Given that injury causality is complex and multifactorial, a variety of improvement strategies were implemented over the following two to three years. IMPLEMENTATION OF POTENTIAL SOLUTIONS: Short-term (a few months), mid-term (six months), and long-term (one year) potential solutions to the LNA back and shoulder injury problem were charted. Safety and health training was the major focus of the team's short-term plan. Risk management forms were to be used to identify and follow up on hazardous situations. Project plans that were successfully implemented included revision of LNA plans of care, standardization of the return-to-work process after injury, development of guidelines for identifying unsafe patient lifts and transfers, improved follow-up of employee reports of injury-risk situations in patient homes, improved body mechanics screening of new employees, and a stronger injury-prevention training program for current employees. A less successful initiative was aimed at collecting more data about injuries and causal factors. Employee injuries were gradually reduced from 4-10 per quarter to 0-3 per quarter. Injury prevention requires commitment, persistence, and patience--but not expensive improvements. Multiple interventions increase the chances of success when there are many root causes and lack of evidence regarding the effectiveness of various approaches.
Molecular Mechanisms of Right Ventricular Failure
Reddy, Sushma; Bernstein, Daniel
2015-01-01
An abundance of data has provided insight into the mechanisms underlying the development of left ventricular (LV) hypertrophy and its progression to LV failure. In contrast, there is minimal data on the adaptation of the right ventricle (RV) to pressure and volume overload and the transition to RV failure. This is a critical clinical question, as the RV is uniquely at risk in many patients with repaired or palliated congenital heart disease and in those with pulmonary hypertension. Standard heart failure therapies have failed to improve function or survival in these patients, suggesting a divergence in the molecular mechanisms of RV vs. LV failure. Although, on the cellular level, the remodeling responses of the RV and LV to pressure overload are largely similar, there are several key differences: the stressed RV is more susceptible to oxidative stress, has a reduced angiogenic response, and is more likely to activate cell death pathways than the stressed LV. Together, these differences could explain the more rapid progression of the RV to failure vs. the LV. This review will highlight known molecular differences between the RV and LV responses to hemodynamic stress, the unique stressors on the RV associated with congenital heart disease, and the need to better understand these molecular mechanisms if we are to develop RV-specific heart failure therapeutics. PMID:26527692
Elasticity dominates strength and failure in metallic glasses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Z. Q.; Qu, R. T.; Zhang, Z. F., E-mail: zhfzhang@imr.ac.cn
2015-01-07
Two distinct deformation mechanisms of shearing and volume dilatation are quantitatively analyzed in metallic glasses (MGs) from the fundamental thermodynamics. Their competition is deduced to intrinsically dominate the strength and failure behaviors of MGs. Both the intrinsic shear and normal strengths give rise to the critical mechanical energies to activate destabilization of amorphous structures, under pure shearing and volume dilatation, respectively, and can be determined in terms of elastic constants. By adopting an ellipse failure criterion, the strength and failure behaviors of MGs can be precisely described just according to their shear modulus and Poisson's ratio without mechanical testing. Quantitativemore » relations are established systematically and verified by experimental results. Accordingly, the real-sense non-destructive failure prediction can be achieved in various MGs. By highlighting the broad key significance of elasticity, a “composition-elasticity-property” scheme is further outlined for better understanding and controlling the mechanical properties of MGs and other glassy materials from the elastic perspectives.« less
Field failure mechanisms for photovoltaic modules
NASA Technical Reports Server (NTRS)
Dumas, L. N.; Shumka, A.
1981-01-01
Beginning in 1976, Department of Energy field centers have installed and monitored a number of field tests and application experiments using current state-of-the-art photovoltaic modules. On-site observations of module physical and electrical degradation, together with in-depth laboratory analysis of failed modules, permits an overall assessment of the nature and causes of early field failures. Data on failure rates are presented, and key failure mechanisms are analyzed with respect to origin, effect, and prospects for correction. It is concluded that all failure modes identified to date are avoidable or controllable through sound design and production practices.
NASA Astrophysics Data System (ADS)
Lee, Chang-Chun; Huang, Pei-Chen; He, Jing-Yan
2018-04-01
Organic light-emitting diode-based flexible and rollable displays have become a promising candidate for next-generation flexible electronics. For this reason, the design of surface multi-layered barriers should be optimized to enhance the long-term mechanical reliability of a flexible encapsulation that prevents the penetration of oxygen and vapor. In this study, finite element-based stress simulation was proposed to estimate the mechanical reliability of gas/vapor barrier design with low-k/silicon nitride (low-k/SiNx) stacking architecture. Consequently, stress-induced failure of critical thin films within the flexible display under various bending conditions must be considered. The feasibility of one pair SiO2/SiNx barrier design, which overcomes the complex lamination process, and the critical bending radius, which is decreased to 1.22 mm, were also examined. In addition, the influence of distance between neutral axes to the concerned layer surface dominated the induced-stress magnitude rather than the stress compliant mechanism provided from stacked low-k films.
Characterization of Mechanical Properties and Residual Stress in API 5L X80 Steel Welded Joints
NASA Astrophysics Data System (ADS)
de Sousa Lins, Amilton; de Souza, Luís Felipe Guimarães; Fonseca, Maria Cindra
2018-01-01
The use of high-strength and low-alloy steels, high design factors and increasingly stringent safety requirements have increased the operating pressure levels and, consequently, the need for further studies to avoid and prevent premature pipe failure. To evaluate the possibility of improving productivity in manual arc welding of this type of steel, this work characterizes the mechanical properties and residual stresses in API 5L X80 steel welded joints using the SMAW and FCAW processes. The residual stresses were analyzed using x-ray diffraction with the sin2 ψ method at the top and root of the welded joints in the longitudinal and transverse directions of the weld bead. The mechanical properties of the welded joints by both processes were characterized in terms of tensile strength, impact toughness and Vickers microhardness in the welded and shot peening conditions. A predominantly compressive residual stress was found, and shot peening increased the tensile strength and impact toughness in both welded joints.
Remodeling of ACL Allografts is Inhibited by Peracetic Acid Sterilization
Gonnermann, Johannes; Kamp, Julia; Przybilla, Dorothea; Pruss, Axel
2008-01-01
Sterilization of allografts for anterior cruciate ligament (ACL) reconstruction has become an important prerequisite to prevent disease transmission. However, current sterilization techniques impair the biological or mechanical properties of such treated grafts. Peracetic acid (PAA) has been successfully used to sterilize bone allografts without these disadvantages and does not impair the mechanical properties of soft tissue grafts in vitro. We asked whether PAA sterilization would influence recellularization, restoration of crimp length and pattern, and revascularization of ACL grafts during early healing. We used an in vivo sheep model for open ACL reconstruction. We also correlated the histologic findings with the restoration of anteroposterior stability and structural properties during load-to-failure testing. PAA slowed remodeling activity at 6 and 12 weeks compared to nonsterilized allografts and autografts. The mechanical properties of PAA grafts were also reduced compared to these control groups at both time points. We conclude PAA sterilization currently should not be used to sterilize soft tissue grafts typically used in ACL reconstruction. PMID:18491201
Molecular mechanism of central nervous system repair by the Drosophila NG2 homologue kon-tiki
Harrison, Neale
2016-01-01
Neuron glia antigen 2 (NG2)–positive glia are repair cells that proliferate upon central nervous system (CNS) damage, promoting functional recovery. However, repair is limited because of the failure of the newly produced glial cells to differentiate. It is a key goal to discover how to regulate NG2 to enable glial proliferation and differentiation conducive to repair. Drosophila has an NG2 homologue called kon-tiki (kon), of unknown CNS function. We show that kon promotes repair and identify the underlying mechanism. Crush injury up-regulates kon expression downstream of Notch. Kon in turn induces glial proliferation and initiates glial differentiation by activating glial genes and prospero (pros). Two negative feedback loops with Notch and Pros allow Kon to drive the homeostatic regulation required for repair. By modulating Kon levels in glia, we could prevent or promote CNS repair. Thus, the functional links between Kon, Notch, and Pros are essential for, and can drive, repair. Analogous mechanisms could promote CNS repair in mammals. PMID:27551055
Mechanical testing of hydrogels in cartilage tissue engineering: beyond the compressive modulus.
Xiao, Yinghua; Friis, Elizabeth A; Gehrke, Stevin H; Detamore, Michael S
2013-10-01
Injuries to articular cartilage result in significant pain to patients and high medical costs. Unfortunately, cartilage repair strategies have been notoriously unreliable and/or complex. Biomaterial-based tissue-engineering strategies offer great promise, including the use of hydrogels to regenerate articular cartilage. Mechanical integrity is arguably the most important functional outcome of engineered cartilage, although mechanical testing of hydrogel-based constructs to date has focused primarily on deformation rather than failure properties. In addition to deformation testing, as the field of cartilage tissue engineering matures, this community will benefit from the addition of mechanical failure testing to outcome analyses, given the crucial clinical importance of the success of engineered constructs. However, there is a tremendous disparity in the methods used to evaluate mechanical failure of hydrogels and articular cartilage. In an effort to bridge the gap in mechanical testing methods of articular cartilage and hydrogels in cartilage regeneration, this review classifies the different toughness measurements for each. The urgency for identifying the common ground between these two disparate fields is high, as mechanical failure is ready to stand alongside stiffness as a functional design requirement. In comparing toughness measurement methods between hydrogels and cartilage, we recommend that the best option for evaluating mechanical failure of hydrogel-based constructs for cartilage tissue engineering may be tensile testing based on the single edge notch test, in part because specimen preparation is more straightforward and a related American Society for Testing and Materials (ASTM) standard can be adopted in a fracture mechanics context.
NASA Astrophysics Data System (ADS)
Das, Arghya; Tengattini, Alessandro; Nguyen, Giang D.; Viggiani, Gioacchino; Hall, Stephen A.; Einav, Itai
2014-10-01
We study the mechanical failure of cemented granular materials (e.g., sandstones) using a constitutive model based on breakage mechanics for grain crushing and damage mechanics for cement fracture. The theoretical aspects of this model are presented in Part I: Tengattini et al. (2014), A thermomechanical constitutive model for cemented granular materials with quantifiable internal variables, Part I - Theory (Journal of the Mechanics and Physics of Solids, 10.1016/j.jmps.2014.05.021). In this Part II we investigate the constitutive and structural responses of cemented granular materials through analyses of Boundary Value Problems (BVPs). The multiple failure mechanisms captured by the proposed model enable the behavior of cemented granular rocks to be well reproduced for a wide range of confining pressures. Furthermore, through comparison of the model predictions and experimental data, the micromechanical basis of the model provides improved understanding of failure mechanisms of cemented granular materials. In particular, we show that grain crushing is the predominant inelastic deformation mechanism under high pressures while cement failure is the relevant mechanism at low pressures. Over an intermediate pressure regime a mixed mode of failure mechanisms is observed. Furthermore, the micromechanical roots of the model allow the effects on localized deformation modes of various initial microstructures to be studied. The results obtained from both the constitutive responses and BVP solutions indicate that the proposed approach and model provide a promising basis for future theoretical studies on cemented granular materials.
Sun, Edward; Alkalay, Ron; Vader, David; Snyder, Brian D
2009-06-01
An in vitro biomechanical study. Compare the mechanical behavior of 5 different constructs used to terminate dual-rod posterior spinal instrumentation in resisting forward flexion moment. Failure of the distal fixation construct can be a significant problem for patients undergoing surgical treatment for thoracic hyperkyphosis. We hypothesize that augmenting distal pedicle screws with infralaminar hooks or sublaminar cables significantly increases the strength and stiffness of these constructs. Thirty-seven thoracolumbar (T12 to L2) calf spines were implanted with 5 configurations of distal constructs: (1) infralaminar hooks, (2) sublaminar cables, (3) pedicle screws, (4) pedicle screws+infralaminar hooks, and (5) pedicle screws+sublaminar cables. Progressive bending moment was applied to each construct until failure. The mode of failure was noted and the construct's stiffness and failure load determined from the load-displacement curves. Bone density and vertebral dimensions were equivalent among the groups (F=0.1 to 0.9, P>0.05). One-way analysis of covariance (adjusted for differences in density and vertebral dimension) demonstrated that all of the screw-constructs (screw, screw+hook, and screw+cable) exhibited significantly higher stiffness and ultimate failure loads compared with either sublaminar hook or cable alone (P<0.05). The screw+hook constructs (109+/-11 Nm/mm) were significantly stiffer than either screws alone (88+/-17 Nm/mm) or screw+cable (98+/-13 Nm/mm) constructs, P<0.05. Screw+cable construct exhibited significantly higher failure load (1336+/-328 N) compared with screw constructs (1102+/-256 N, P<0.05), whereas not statistically different from the screw+hook construct (1220+/-75 N). The cable and hook constructs failed by laminar fracture, screw construct failed in uniaxial shear (pullout), whereas the screws+(hooks or wires) failed by fracture of caudal vertebral body. Posterior dual rod constructs fixed distally using pedicle screws were stiffer and stronger in resisting forward flexion compared with cables or hooks alone. Augmenting these screws with either infralaminar hooks or sublaminar cables provided additional resistance to failure.
Jin, Li; Piao, Zhe Hao; Sun, Simei; Liu, Bin; Ryu, Yuhee; Choi, Sin Young; Kim, Gwi Ran; Kim, Hyung-Seok; Kee, Hae Jin; Jeong, Myung Ho
2017-12-01
Gallic acid, a trihydroxybenzoic acid found in tea and other plants, attenuates cardiac hypertrophy, fibrosis, and hypertension in animal models. However, the role of gallic acid in heart failure remains unknown. In this study, we show that gallic acid administration prevents heart failure-induced pulmonary fibrosis. Heart failure induced in mice, 8weeks after transverse aortic constriction (TAC) surgery, was confirmed by echocardiography. Treatment for 2weeks with gallic acid but not furosemide prevented cardiac dysfunction in mice. Gallic acid significantly inhibited TAC-induced pathological changes in the lungs, such as increased lung mass, pulmonary fibrosis, and damaged alveolar morphology. It also decreased the expression of fibrosis-related genes, including collagen types I and III, fibronectin, connective tissue growth factor (CTGF), and phosphorylated Smad3. Further, it inhibited the expression of epithelial-mesenchymal transition (EMT)-related genes, such as N-cadherin, vimentin, E-cadherin, SNAI1, and TWIST1. We suggest that gallic acid has therapeutic potential for the treatment of heart failure-induced pulmonary fibrosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Mechanical ventilation for severe asthma.
Leatherman, James
2015-06-01
Acute exacerbations of asthma can lead to respiratory failure requiring ventilatory assistance. Noninvasive ventilation may prevent the need for endotracheal intubation in selected patients. For patients who are intubated and undergo mechanical ventilation, a strategy that prioritizes avoidance of ventilator-related complications over correction of hypercapnia was first proposed 30 years ago and has become the preferred approach. Excessive pulmonary hyperinflation is a major cause of hypotension and barotrauma. An appreciation of the key determinants of hyperinflation is essential to rational ventilator management. Standard therapy for patients with asthma undergoing mechanical ventilation consists of inhaled bronchodilators, corticosteroids, and drugs used to facilitate controlled hypoventilation. Nonconventional interventions such as heliox, general anesthesia, bronchoscopy, and extracorporeal life support have also been advocated for patients with fulminant asthma but are rarely necessary. Immediate mortality for patients who are mechanically ventilated for acute severe asthma is very low and is often associated with out-of-hospital cardiorespiratory arrest before intubation. However, patients who have been intubated for severe asthma are at increased risk for death from subsequent exacerbations and must be managed accordingly in the outpatient setting.
Razavi, Mehdi; Fathi, Mohammadhossein; Savabi, Omid; Hashemi Beni, Batoul; Vashaee, Daryoosh; Tayebi, Lobat
2014-05-01
Magnesium (Mg) alloys, owing to their biodegradability and good mechanical properties, have potential applications as biodegradable orthopedic implants. However, several poor properties including low corrosion resistance, mechanical stability and cytocompatibility have prevented their clinical application, as these properties may result in the sudden failure of the implants during the bone healing. In this research, nanostructured akermanite (Ca2MgSi2O7) powder was coated on the AZ91 Mg alloy through electrophoretic deposition (EPD) assisted micro arc oxidation (MAO) method to modify the properties of the alloy. The surface microstructure of coating, corrosion resistance, mechanical stability and cytocompatibility of the samples were characterized with different techniques including X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), electrochemical corrosion test, immersion test, compression test and cell culture test. The results showed that the nanostructured akermanite coating can improve the corrosion resistance, mechanical stability and cytocompatibility of the biodegradable Mg alloy making it a promising material to be used as biodegradable bone implants for orthopedic applications. Published by Elsevier B.V.
Deformation behavior of FRP-metal composites locally reinforced with carbon fibers
NASA Astrophysics Data System (ADS)
Scholze, M.; Kolonko, A.; Lindner, T.; Lampke, T.; Helbig, F.
2016-03-01
This study investigates variations of hybrid laminates, consisting of one aluminum sheet and a unidirectional glass fiber (GF) reinforced polyamide 6 (PA6) basic structure with partial carbon fiber (CF) reinforcement. To create these heterogeneous FRP laminates, it is necessary to design and produce semi-finished textile-based products. Moreover, a warp knitting machine in conjunction with a warp thread offset unit was used to generate bionic inspired compounds. By the variation of stacking prior to the consolidation process of the hybrid laminate, an oriented CF reinforcement at the top and middle layer of the FRP is realized. In both cases the GFRP layer prevents contact between the aluminum and carbon fibers. In so doing, the high strength of carbon fibers can be transferred to the hybrid laminate in load directions with an active prevention of contact corrosion. The interface strength between thermoplastic and metal component was improved by a thermal spray coating on the aluminum sheet. Because of the high surface roughness and porosity, mechanical interlock was used to provide high interface strength without bonding agents between both components. The resulting mechanical properties of the hybrid laminates are evaluated by three point bending tests in different load directions. The effect of local fiber orientation and layer positioning on failure and deformation mechanism is additionally investigated by digital image correlation (DIC).
Causes and prevention of splitting/bursting failure of concrete crossties: a computational study
DOT National Transportation Integrated Search
2017-09-17
Concrete splitting/bursting is a well-known failure mode of concrete crossties that can compromise the crosstie integrity and raise railroad maintenance and track safety concerns. This paper presents a computational study aimed at better understandin...
36 CFR 223.137 - Causes for debarment.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., fire prevention, and the disposal of slash; (2) Protection of soil, water, wildlife, range, cultural, and timber resources and protection of improvements when such failure causes significant environmental, resource, or improvements damage; (3) Removal of designated timber when such failure causes substantial...
Code of Federal Regulations, 2010 CFR
2010-07-01
... by common walls, where coal undergoes destructive distillation under positive pressure to produce..., infrequent, and not reasonably preventable failure of air pollution control equipment, process equipment, or... emission limitations in an applicable standard to be exceeded. Failures caused in part by poor maintenance...
The resistance of cortical bone tissue to failure under cyclic loading is reduced with alendronate.
Bajaj, Devendra; Geissler, Joseph R; Allen, Matthew R; Burr, David B; Fritton, J C
2014-07-01
Bisphosphonates are the most prescribed preventative treatment for osteoporosis. However, their long-term use has recently been associated with atypical fractures of cortical bone in patients who present with low-energy induced breaks of unclear pathophysiology. The effects of bisphosphonates on the mechanical properties of cortical bone have been exclusively studied under simple, monotonic, quasi-static loading. This study examined the cyclic fatigue properties of bisphosphonate-treated cortical bone at a level in which tissue damage initiates and is accumulated prior to frank fracture in low-energy situations. Physiologically relevant, dynamic, 4-point bending applied to beams (1.5 mm × 0.5 mm × 10 mm) machined from dog rib (n=12/group) demonstrated mechanical failure and micro-architectural features that were dependent on drug dose (3 groups: 0, 0.2, 1.0mg/kg/day; alendronate [ALN] for 3 years) with cortical bone tissue elastic modulus (initial cycles of loading) reduced by 21% (p<0.001) and fatigue life (number of cycles to failure) reduced in a stress-life approach by greater than 3-fold with ALN1.0 (p<0.05). While not affecting the number of osteons, ALN treatment reduced other features associated with bone remodeling, such as the size of osteons (-14%; ALN1.0: 10.5±1.8, VEH: 12.2±1.6, ×10(3) μm2; p<0.01) and the density of osteocyte lacunae (-20%; ALN1.0: 11.4±3.3, VEH: 14.3±3.6, ×10(2) #/mm2; p<0.05). Furthermore, the osteocyte lacunar density was directly proportional to initial elastic modulus when the groups were pooled (R=0.54, p<0.01). These findings suggest that the structural components normally contributing to healthy cortical bone tissue are altered by high-dose ALN treatment and contribute to reduced mechanical properties under cyclic loading conditions. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cao, Ri-hong; Cao, Ping; Lin, Hang; Pu, Cheng-zhi; Ou, Ke
2016-03-01
Joints and fissures with similar orientation or characteristics are common in natural rocks; the inclination and density of the fissures affect the mechanical properties and failure mechanism of the rock mass. However, the strength, crack coalescence pattern, and failure mode of rock specimens containing multi-fissures have not been studied comprehensively. In this paper, combining similar material testing and discrete element numerical method (PFC2D), the peak strength and failure characteristics of rock-like materials with multi-fissures are explored. Rock-like specimens were made of cement and sand and pre-existing fissures created by inserting steel shims into cement mortar paste and removing them during curing. The peak strength of multi-fissure specimens depends on the fissure angle α (which is measured counterclockwise from horizontal) and fissure number ( N f). Under uniaxial compressional loading, the peak strength increased with increasing α. The material strength was lowest for α = 25°, and highest for α = 90°. The influence of N f on the peak strength depended on α. For α = 25° and 45°, N f had a strong effect on the peak strength, while for higher α values, especially for the 90° sample, there were no obvious changes in peak strength with different N f. Under uniaxial compression, the coalescence modes between the fissures can be classified into three categories: S-mode, T-mode, and M-mode. Moreover, the failure mode can be classified into four categories: mixed failure, shear failure, stepped path failure, and intact failure. The failure mode of the specimen depends on α and N f. The peak strength and failure modes in the numerically simulated and experimental results are in good agreement.
Arnold, J Malcolm O; Howlett, Jonathan G; Dorian, Paul; Ducharme, Anique; Giannetti, Nadia; Haddad, Haissam; Heckman, George A; Ignaszewski, Andrew; Isaac, Debra; Jong, Philip; Liu, Peter; Mann, Elizabeth; McKelvie, Robert S; Moe, Gordon W; Parker, John D; Svendsen, Anna M; Tsuyuki, Ross T; O’Halloran, Kelly; Ross, Heather J; Rao, Vivek; Sequeira, Errol J; White, Michel
2007-01-01
Heart failure is common, yet it is difficult to treat. It presents in many different guises and circumstances in which therapy needs to be individualized. The Canadian Cardiovascular Society published a comprehensive set of recommendations in January 2006 on the diagnosis and management of heart failure, and the present update builds on those core recommendations. Based on feedback obtained through a national program of heart failure workshops during 2006, several topics were identified as priorities because of the challenges they pose to health care professionals. New evidence-based recommendations were developed using the structured approach for the review and assessment of evidence adopted and previously described by the Society. Specific recommendations and practical tips were written for the prevention of heart failure, the management of heart failure during intercurrent illness, the treatment of acute heart failure, and the current and future roles of biomarkers in heart failure care. Specific clinical questions that are addressed include: which patients should be identified as being at high risk of developing heart failure and which interventions should be used? What complications can occur in heart failure patients during an intercurrent illness, how should these patients be monitored and which medications may require a dose adjustment or discontinuation? What are the best therapeutic, both drug and nondrug, strategies for patients with acute heart failure? How can new biomarkers help in the treatment of heart failure, and when and how should BNP be measured in heart failure patients? The goals of the present update are to translate best evidence into practice, to apply clinical wisdom where evidence for specific strategies is weaker, and to aid physicians and other health care providers to optimally treat heart failure patients to result in a measurable impact on patient health and clinical outcomes in Canada. PMID:17245481
Arnold, J Malcom O; Howlett, Jonathan G; Dorian, Paul; Ducharme, Anique; Giannetti, Nadia; Haddad, Haissam; Heckman, George A; Ignaszewski, Andrew; Isaac, Debra; Jong, Philip; Liu, Peter; Mann, Elizabeth; McKelvie, Robert S; Moe, Gordon W; Parker, John D; Svendsen, Anna M; Tsuyuki, Ross T; O'Halloran, Kelly; Ross, Heather J; Rao, Vivek; Sequeira, Errol J; White, Michel
2007-01-01
Heart failure is common, yet it is difficult to treat. It presents in many different guises and circumstances in which therapy needs to be individualized. The Canadian Cardiovascular Society published a comprehensive set of recommendations in January 2006 on the diagnosis and management of heart failure, and the present update builds on those core recommendations. Based on feedback obtained through a national program of heart failure workshops during 2006, several topics were identified as priorities because of the challenges they pose to health care professionals. New evidence-based recommendations were developed using the structured approach for the review and assessment of evidence adopted and previously described by the Society. Specific recommendations and practical tips were written for the prevention of heart failure, the management of heart failure during intercurrent illness, the treatment of acute heart failure, and the current and future roles of biomarkers in heart failure care. Specific clinical questions that are addressed include: which patients should be identified as being at high risk of developing heart failure and which interventions should be used? What complications can occur in heart failure patients during an intercurrent illness, how should these patients be monitored and which medications may require a dose adjustment or discontinuation? What are the best therapeutic, both drug and nondrug, strategies for patients with acute heart failure? How can new biomarkers help in the treatment of heart failure, and when and how should BNP be measured in heart failure patients? The goals of the present update are to translate best evidence into practice, to apply clinical wisdom where evidence for specific strategies is weaker, and to aid physicians and other health care providers to optimally treat heart failure patients to result in a measurable impact on patient health and clinical outcomes in Canada.
Requirements for energy based constitutive modeling in tire mechanics
NASA Technical Reports Server (NTRS)
Luchini, John R.; Peters, Jim M.; Mars, Will V.
1995-01-01
The history, requirements, and theoretical basis of a new energy based constitutive model for (rubber) material elasticity, hysteresis, and failure are presented. Energy based elasticity is handled by many constitutive models, both in one dimension and in three dimensions. Conversion of mechanical energy to heat can be modeled with viscoelasticity or as structural hysteresis. We are seeking unification of elasticity, hysteresis, and failure mechanisms such as fatigue and wear. An energy state characterization for failure criteria of (rubber) materials may provide this unification and also help explain the interaction of temperature effects with failure mechanisms which are described as creation of growth of internal crack surface. Improved structural modeling of tires with FEM should result from such a unified constitutive theory. The theory will also guide experimental work and should enable better interpretation of the results of computational stress analyses.
An autonomous recovery mechanism against optical distribution network failures in EPON
NASA Astrophysics Data System (ADS)
Liem, Andrew Tanny; Hwang, I.-Shyan; Nikoukar, AliAkbar
2014-10-01
Ethernet Passive Optical Network (EPON) is chosen for servicing diverse applications with higher bandwidth and Quality-of-Service (QoS), starting from Fiber-To-The-Home (FTTH), FTTB (business/building) and FTTO (office). Typically, a single OLT can provide services to both residential and business customers on the same Optical Line Terminal (OLT) port; thus, any failures in the system will cause a great loss for both network operators and customers. Network operators are looking for low-cost and high service availability mechanisms that focus on the failures that occur within the drop fiber section because the majority of faults are in this particular section. Therefore, in this paper, we propose an autonomous recovery mechanism that provides protection and recovery against Drop Distribution Fiber (DDF) link faults or transceiver failure at the ONU(s) in EPON systems. In the proposed mechanism, the ONU can automatically detect any signal anomalies in the physical layer or transceiver failure, switching the working line to the protection line and sending the critical event alarm to OLT via its neighbor. Each ONU has a protection line, which is connected to the nearest neighbor ONU, and therefore, when failure occurs, the ONU can still transmit and receive data via the neighbor ONU. Lastly, the Fault Dynamic Bandwidth Allocation for recovery mechanism is presented. Simulation results show that our proposed autonomous recovery mechanism is able to maintain the overall QoS performance in terms of mean packet delay, system throughput, packet loss and EF jitter.
McNamee, J J; Gillies, M A; Barrett, N A; Agus, A M; Beale, R; Bentley, A; Bodenham, A; Brett, S J; Brodie, D; Finney, S J; Gordon, A J; Griffiths, M; Harrison, D; Jackson, C; McDowell, C; McNally, C; Perkins, G D; Tunnicliffe, W; Vuylsteke, A; Walsh, T S; Wise, M P; Young, D; McAuley, D F
2017-05-01
One of the few interventions to demonstrate improved outcomes for acute hypoxaemic respiratory failure is reducing tidal volumes when using mechanical ventilation, often termed lung protective ventilation. Veno-venous extracorporeal carbon dioxide removal (vv-ECCO 2 R) can facilitate reducing tidal volumes. pRotective vEntilation with veno-venouS lung assisT (REST) is a randomised, allocation concealed, controlled, open, multicentre pragmatic trial to determine the clinical and cost-effectiveness of lower tidal volume mechanical ventilation facilitated by vv-ECCO 2 R in patients with acute hypoxaemic respiratory failure. Patients requiring intubation and mechanical ventilation for acute hypoxaemic respiratory failure will be randomly allocated to receive either vv-ECCO 2 R and lower tidal volume mechanical ventilation or standard care with stratification by recruitment centre. There is a need for a large randomised controlled trial to establish whether vv-ECCO 2 R in acute hypoxaemic respiratory failure can allow the use of a more protective lung ventilation strategy and is associated with improved patient outcomes.
Progress and prospect on failure mechanisms of solid-state lithium batteries
NASA Astrophysics Data System (ADS)
Ma, Jun; Chen, Bingbing; Wang, Longlong; Cui, Guanglei
2018-07-01
By replacing traditional liquid organic electrolyte with solid-state electrolyte, the solid-state lithium batteries powerfully come back to the energy storage field due to their eminent safety and energy density. In recent years, a variety of solid-state lithium batteries based on excellent solid-state electrolytes are developed. However, the performance degradation of solid-state lithium batteries during cycling and storing is still a serious challenge for practical application. Therefore, this review summarizes the research progress of solid-state lithium batteries from the perspectives of failure phenomena and failure mechanisms. Additionally, the development of methodologies on studying the failure mechanisms of solid-state lithium batteries is also reviewed. Moreover, some perspectives on the remaining questions for understanding the failure behaviors and achieving long cycle life, high safety and high energy density solid-state lithium batteries are presented. This review will help researchers to recognize the status of solid-state lithium batteries objectively and attract much more research interest in conquering the failure issues of solid-state lithium batteries.
Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H
2003-10-01
Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.
Failure of flight feathers under uniaxial compression.
Schelestow, Kristina; Troncoso, Omar P; Torres, Fernando G
2017-09-01
Flight feathers are light weight engineering structures. They have a central shaft divided in two parts: the calamus and the rachis. The rachis is a thinly walled conical shell filled with foam, while the calamus is a hollow tube-like structure. Due to the fact that bending loads are produced during birds' flight, the resistance to bending of feathers has been reported in different studies. However, the analysis of bent feathers has shown that compression could induce failure by buckling. Here, we have studied the compression of feathers in order to assess the failure mechanisms involved. Axial compression tests were carried out on the rachis and the calamus of dove and pelican feathers. The failure mechanisms and folding structures that resulted from the compression tests were observed from images obtained by scanning electron microscopy (SEM). The rachis and calamus fail due to structural instability. In the case of the calamus, this instability leads to a progressive folding process. In contrast, the rachis undergoes a typical Euler column-type buckling failure. The study of failed specimens showed that delamination buckling, cell collapse and cell densification are the primary failure mechanisms of the rachis structure. The role of the foam is also discussed with regard to the mechanical response of the samples and the energy dissipated during the compression tests. Critical stress values were calculated using delamination buckling models and were found to be in very good agreement with the experimental values measured. Failure analysis and mechanical testing have confirmed that flight feathers are complex thin walled structures with mechanical adaptations that allow them to fulfil their functions. Copyright © 2017 Elsevier B.V. All rights reserved.
Butler, Javed; Hamo, Carine E; Filippatos, Gerasimos; Pocock, Stuart J; Bernstein, Richard A; Brueckmann, Martina; Cheung, Alfred K; George, Jyothis T; Green, Jennifer B; Januzzi, James L; Kaul, Sanjay; Lam, Carolyn S P; Lip, Gregory Y H; Marx, Nikolaus; McCullough, Peter A; Mehta, Cyrus R; Ponikowski, Piotr; Rosenstock, Julio; Sattar, Naveed; Salsali, Afshin; Scirica, Benjamin M; Shah, Sanjiv J; Tsutsui, Hiroyuki; Verma, Subodh; Wanner, Christoph; Woerle, Hans-Juergan; Zannad, Faiez; Anker, Stefan D
2017-11-01
Heart failure (HF) and type 2 diabetes mellitus (T2DM) are both growing public health concerns contributing to major medical and economic burdens to society. T2DM increases the risk of HF, frequently occurs concomitantly with HF, and worsens the prognosis of HF. Several anti-hyperglycaemic medications have been associated with a concern for worse HF outcomes. More recently, the results of the EMPA-REG OUTCOME trial showed that the sodium-glucose co-transporter 2 (SGLT2) inhibitor empagliflozin was associated with a pronounced and precocious 38% reduction in cardiovascular mortality in subjects with T2DM and established cardiovascular disease [Correction added on 8 September 2017, after first online publication: "32%" in the previous sentence was corrected to "38%"]. These benefits were more related to a reduction in incident HF events rather than to ischaemic vascular endpoints. Several mechanisms have been put forward to explain these benefits, which also raise the possibility of using these drugs as therapies not only in the prevention of HF, but also for the treatment of patients with established HF regardless of the presence or absence of diabetes. Several large trials are currently exploring this postulate. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of Cardiology.
Kheirollahi, Hossein
2015-01-01
Accurate assessment of hip fracture risk is very important to prevent hip fracture and to monitor the effect of a treatment. A subject-specific QCT-based finite element model was constructed to assess hip fracture risk at the critical locations of femur during the single-leg stance and the sideways fall. The aim of this study was to improve the prediction of hip fracture risk by introducing a novel failure criterion to more accurately describe bone failure mechanism. Hip fracture risk index was defined using cross-section strain energy, which is able to integrate information of stresses, strains, and material properties affecting bone failure. It was found that the femoral neck and the intertrochanteric region have higher fracture risk than other parts of the femur, probably owing to the larger content of cancellous bone in these regions. The study results also suggested that women are more prone to hip fracture than men. The findings in this study have a good agreement with those clinical observations reported in the literature. The proposed hip fracture risk index based on strain energy has the potential of more accurate assessment of hip fracture risk. However, experimental validation should be conducted before its clinical applications. PMID:26601105
Ebner, Thomas; Moser, Marianne; Shebl, Omar; Mayer, Richard; Tews, Gernot
2011-01-01
Objective This prospective study was set up in order to analyze whether additional treatment (cutting off supernumerous cumulus cells; adding hyaluronidase) of the cumulus-oocyte-complex (COC) would help to improve treatment outcome. Material and Methods COCs from 50 patients were prospectively subdivided into a control group A (no manipulation of COC) and two study groups. In group B, surplus cumulus cells were cut off using syringes, and in the second study group COCs were incubated with a 1:11 dilution of hyaluronidase (final concentration 7 IU/l). Main outcome measures were fertilization rate, embryo development, as well as rates of implantation, pregnancy, and live birth. Results Fertilization was higher in group C as compared to the untreated control group A (p<0.05). However, complete fertilization failure could not be avoided by any of the modified IVF approaches. Compaction on day 4 and blastocyst quality on day 5 were significantly improved in group C as compared to group B (but not to group A). Rates of implantation, pregnancy, and live birth were not affected by any of the methods. Conclusion ICSI seems to be the only choice for avoiding the vast majority of fertilization failures after IVF. PMID:24591979
NASA Astrophysics Data System (ADS)
Rahman, Abdul Ghaffar Abdul; Noroozi, Siamak; Dupac, Mihai; Mahathir Syed Mohd Al-Attas, Syed; Vinney, John E.
2013-03-01
Complex rotating machinery requires regular condition monitoring inspections to assess their running conditions and their structural integrity to prevent catastrophic failures. Machine failures can be divided into two categories. First is the wear and tear during operation, they range from bearing defects, gear damage, misalignment, imbalance or mechanical looseness, for which simple condition-based maintenance techniques can easily detect the root cause and trigger remedial action process. The second factor in machine failure is caused by the inherent design faults that usually happened due to many reasons such as improper installation, poor servicing, bad workmanship and structural dynamics design deficiency. In fact, individual machines components are generally dynamically well designed and rigorously tested. However, when these machines are assembled on sight and linked together, their dynamic characteristics will change causing unexpected behaviour of the system. Since nondestructive evaluation provides an excellent alternative to the classical monitoring and proved attractive due to the possibility of performing reliable assessments of all types of machinery, the novel dynamic design verification procedure - based on the combination of in-service operation deflection shape measurement, experimental modal analysis and iterative inverse finite element analysis - proposed here allows quick identification of structural weakness, and helps to provide and verify the solutions.
Tensile Response of Hoop Reinforced Multiaxially Braided Thin Wall Composite Tubes
NASA Astrophysics Data System (ADS)
Roy, Sree Shankhachur; Potluri, Prasad; Soutis, Constantinos
2017-04-01
This paper presents the tensile response of thin-walled composite tubes with multi-axial fibre architecture. A hybrid braid-wound layup has the potential to optimise the composite tube properties, however, stacking sequence plays a role in the failure mechanism. A braid-winding method has been used to produce stacked overwound braid layup [(±45°/0°)5/90°4]T. Influence of stacking sequence on premature failure of hoop layers has been reported. Under tensile loading, a cross-ply composite tube with the alternate stacking of hoop and axial fibre show hoop plies splitting similar to the overwound braided composite tube. However, splitting has been restricted by the surrounding axial plies and contained between the adjacent axial fibre tows. This observation suggests hoop layers sandwiched between braid layers will improve structural integrity. A near net shape architecture with three fibre orientation in a triaxial braid will provide additional support to prevent extensive damage for plies loaded in off-axis. Several notable observations for relatively open braid structures such as tow scissoring, high Poisson's ratio and influence of axial tow crimp on the strain to failure have been reported. Digital Image Correlation (DIC) in conjunction with surface strain gauging has been employed to capture the strain pattern.
Zeng, Fangxinyu; Chen, Jinyao; Yang, Feng; Kang, Jian; Cao, Ya; Xiang, Ming
2018-01-16
In this study, polyamide-aluminum foil-polypropylene (PA-Al-PP) composite films with different orientation status of the PP layer were prepared, and their morphology, tensile, peeling and heat seal behavior were studied. The comparative study of tensile and fracture behaviors of single-layer film of PA, Al and PP, as well as the composite films of PA-Al, PP-Al and PA-Al-PP revealed that in PA-Al-PP composite film, the PA layer with the highest tensile strength can share the tensile stress from the Al layer during stretching, while the PP layer with the lowest tensile strength can prevent further development of the small cracks on boundary of the Al layer during stretching. Moreover, the study of heat seal behavior suggested that both the orientation status and the heat seal conditions were important factors in determining the heat seal strength ( HSS ) and failure behavior of the sample. Four failure types were observed, and a clear correspondence between HSS and failure types was found. The results also elucidated that for the composite film, only in the cases where the tensile stress was efficiently released by each layer during HSS measurement could the composite film exhibit desired high HSS that was even higher than its tensile strength.
STUDY OF THE RHIC BPM SMA CONNECTOR FAILURE PROBLEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
LIAW,C.; SIKORA, R.; SCHROEDER, R.
2007-06-25
About 730 BPMs are mounted on the RHIC CQS and Triplet super-conducting magnets. Semi-rigid coaxial cables are used to bring the electrical signal from the BPM feedthroughs to the outside flanges. at the ambient temperature. Every year around 10 cables will lose their signals during the operation. The connection usually failed at the warm end of the cable. The problems were either the solder joint failed or the center conductor retracted out of the SMA connector. Finite element analyses were performed to understand the failure mechanism of the solder joint. The results showed that (1) The SMA center conductor canmore » separate from the mating connector due to the thermal retraction. (2) The maximum thermal stress at the warm end solder joint can exceed the material strength of the Pb37/Sn63 solder material and (3) The magnet ramping frequency (-10 Hz), during the machine startup, can possibly resonant the coaxial cable and damage the solder joints, especially when a fracture is initiated. Test results confirmed that by using the silver bearing solder material (a higher strength material) and by crimping the cable at the locations close to the SMA connector (to prevent the center conductor from retracting) can effectively resolve the connector failure problem.« less
What Reliability Engineers Should Know about Space Radiation Effects
NASA Technical Reports Server (NTRS)
DiBari, Rebecca
2013-01-01
Space radiation in space systems present unique failure modes and considerations for reliability engineers. Radiation effects is not a one size fits all field. Threat conditions that must be addressed for a given mission depend on the mission orbital profile, the technologies of parts used in critical functions and on application considerations, such as supply voltages, temperature, duty cycle, and redundancy. In general, the threats that must be addressed are of two types-the cumulative degradation mechanisms of total ionizing dose (TID) and displacement damage (DD). and the prompt responses of components to ionizing particles (protons and heavy ions) falling under the heading of single-event effects. Generally degradation mechanisms behave like wear-out mechanisms on any active components in a system: Total Ionizing Dose (TID) and Displacement Damage: (1) TID affects all active devices over time. Devices can fail either because of parametric shifts that prevent the device from fulfilling its application or due to device failures where the device stops functioning altogether. Since this failure mode varies from part to part and lot to lot, lot qualification testing with sufficient statistics is vital. Displacement damage failures are caused by the displacement of semiconductor atoms from their lattice positions. As with TID, failures can be either parametric or catastrophic, although parametric degradation is more common for displacement damage. Lot testing is critical not just to assure proper device fi.mctionality throughout the mission. It can also suggest remediation strategies when a device fails. This paper will look at these effects on a variety of devices in a variety of applications. This paper will look at these effects on a variety of devices in a variety of applications. (2) On the NEAR mission a functional failure was traced to a PIN diode failure caused by TID induced high leakage currents. NEAR was able to recover from the failure by reversing the current of a nearby Thermal Electric Cooler (turning the TEC into a heater). The elevated temperature caused the PIN diode to anneal and the device to recover. It was by lot qualification testing that NEAR knew the diode would recover when annealed. This paper will look at these effects on a variety of devices in a variety of applications. Single Event Effects (SEE): (1) In contrast to TID and displacement damage, Single Event Effects (SEE) resemble random failures. SEE modes can range from changes in device logic (single-event upset, or SEU). temporary disturbances (single-event transient) to catastrophic effects such as the destructive SEE modes, single-event latchup (SEL). single-event gate rupture (SEGR) and single-event burnout (SEB) (2) The consequences of nondestructive SEE modes such as SEU and SET depend critically on their application--and may range from trivial nuisance errors to catastrophic loss of mission. It is critical not just to ensure that potentially susceptible devices are well characterized for their susceptibility, but also to work with design engineers to understand the implications of each error mode. -For destructive SEE, the predominant risk mitigation strategy is to avoid susceptible parts, or if that is not possible. to avoid conditions under which the part may be susceptible. Destructive SEE mechanisms are often not well understood, and testing is slow and expensive, making rate prediction very challenging. (3) Because the consequences of radiation failure and degradation modes depend so critically on the application as well as the component technology, it is essential that radiation, component. design and system engineers work togetherpreferably starting early in the program to ensure critical applications are addressed in time to optimize the probability of mission success.
NASA Technical Reports Server (NTRS)
Prassinos, Peter G.; Lyver, John W., IV; Bui, Chinh T.
2011-01-01
Risk assessment is used in many industries to identify and manage risks. Initially developed for use on aeronautical and nuclear systems, risk assessment has been applied to transportation, chemical, computer, financial, and security systems among others. It is used to gain an understanding of the weaknesses or vulnerabilities in a system so modification can be made to increase operability, efficiency, and safety and to reduce failure and down-time. Risk assessment results are primary inputs to risk-informed decision making; where risk information including uncertainty is used along with other pertinent information to assist management in the decision-making process. Therefore, to be useful, a risk assessment must be directed at specific objectives. As the world embraces the globalization of trade and manufacturing, understanding the associated risk become important to decision making. Applying risk assessment techniques to a global system of development, manufacturing, and transportation can provide insight into how the system can fail, the likelihood of system failure and the consequences of system failure. The risk assessment can identify those elements that contribute most to risk and identify measures to prevent and mitigate failures, disruptions, and damaging outcomes. In addition, risk associated with public and environment impact can be identified. The risk insights gained can be applied to making decisions concerning suitable development and manufacturing locations, supply chains, and transportation strategies. While risk assessment has been mostly applied to mechanical and electrical systems, the concepts and techniques can be applied across other systems and activities. This paper provides a basic overview of the development of a risk assessment.
Deficiencies in the uterine environment and failure to support embryo development
USDA-ARS?s Scientific Manuscript database
Pregnancy failure in livestock can result from failure to fertilize the oocyte or embryonic loss during gestation. Although fertilization failure occurs, embryonic mortality has a greater contribution to pregnancy failure. The focus of this review is on cattle and factors affecting, and mechanisms r...
Determination of Turbine Blade Life from Engine Field Data
NASA Technical Reports Server (NTRS)
Zaretsky, Erwin V.; Litt, Jonathan S.; Hendricks, Robert C.; Soditus, Sherry M.
2012-01-01
It is probable that no two engine companies determine the life of their engines or their components in the same way or apply the same experience and safety factors to their designs. Knowing the failure mode that is most likely to occur minimizes the amount of uncertainty and simplifies failure and life analysis. Available data regarding failure mode for aircraft engine blades, while favoring low-cycle, thermal mechanical fatigue as the controlling mode of failure, are not definitive. Sixteen high-pressure turbine (HPT) T-1 blade sets were removed from commercial aircraft engines that had been commercially flown by a single airline and inspected for damage. Each set contained 82 blades. The damage was cataloged into three categories related to their mode of failure: (1) Thermal-mechanical fatigue, (2) Oxidation/Erosion, and (3) "Other." From these field data, the turbine blade life was determined as well as the lives related to individual blade failure modes using Johnson-Weibull analysis. A simplified formula for calculating turbine blade life and reliability was formulated. The L(sub 10) blade life was calculated to be 2427 cycles (11 077 hr). The resulting blade life attributed to oxidation/erosion equaled that attributed to thermal-mechanical fatigue. The category that contributed most to blade failure was Other. If there were there no blade failures attributed to oxidation/erosion and thermal-mechanical fatigue, the overall blade L(sub 10) life would increase approximately 11 to 17 percent.
O'Leary, Siobhan A; Mulvihill, John J; Barrett, Hilary E; Kavanagh, Eamon G; Walsh, Michael T; McGloughlin, Tim M; Doyle, Barry J
2015-02-01
Varying degrees of calcification are present in most abdominal aortic aneurysms (AAAs). However, their impact on AAA failure properties and AAA rupture risk is unclear. The aim of this work is evaluate and compare the failure properties of partially calcified and predominantly fibrous AAA tissue and investigate the potential reasons for failure. Uniaxial mechanical testing was performed on AAA samples harvested from 31 patients undergoing open surgical repair. Individual tensile samples were divided into two groups: fibrous (n=31) and partially calcified (n=38). The presence of calcification was confirmed by fourier transform infrared spectroscopy (FTIR). A total of 69 mechanical tests were performed and the failure stretch (λf), failure stress (σf) and failure tension (Tf) were recorded for each test. Following mechanical testing, the failure sites of a subset of both tissue types were examined using scanning electron microscopy (SEM)/energy dispersive X-ray spectroscopy (EDS) to investigate the potential reasons for failure. It has been shown that the failure properties of partially calcified tissue are significantly reduced compared to fibrous tissue and SEM and EDS results suggest that the junction between a calcification deposit and the fibrous matrix is highly susceptible to failure. This study implicates the presence of calcification as a key player in AAA rupture risk and provides further motivation for the development of non-invasive methods of measuring calcification. Copyright © 2014 Elsevier Ltd. All rights reserved.
Rodríguez, Alejandro; Ferri, Cristina; Martin-Loeches, Ignacio; Díaz, Emili; Masclans, Joan R; Gordo, Federico; Sole-Violán, Jordi; Bodí, María; Avilés-Jurado, Francesc X; Trefler, Sandra; Magret, Monica; Moreno, Gerard; Reyes, Luis F; Marin-Corral, Judith; Yebenes, Juan C; Esteban, Andres; Anzueto, Antonio; Aliberti, Stefano; Restrepo, Marcos I
2017-10-01
Despite wide use of noninvasive ventilation (NIV) in several clinical settings, the beneficial effects of NIV in patients with hypoxemic acute respiratory failure (ARF) due to influenza infection remain controversial. The aim of this study was to identify the profile of patients with risk factors for NIV failure using chi-square automatic interaction detection (CHAID) analysis and to determine whether NIV failure is associated with ICU mortality. This work was a secondary analysis from prospective and observational multi-center analysis in critically ill subjects admitted to the ICU with ARF due to influenza infection requiring mechanical ventilation. Three groups of subjects were compared: (1) subjects who received NIV immediately after ICU admission for ARF and then failed (NIV failure group); (2) subjects who received NIV immediately after ICU admission for ARF and then succeeded (NIV success group); and (3) subjects who received invasive mechanical ventilation immediately after ICU admission for ARF (invasive mechanical ventilation group). Profiles of subjects with risk factors for NIV failure were obtained using CHAID analysis. Of 1,898 subjects, 806 underwent NIV, and 56.8% of them failed. Acute Physiology and Chronic Health Evaluation II (APACHE II) score, Sequential Organ Failure Assessment (SOFA) score, infiltrates in chest radiograph, and ICU mortality (38.4% vs 6.3%) were higher ( P < .001) in the NIV failure than in the NIV success group. SOFA score was the variable most associated with NIV failure, and 2 cutoffs were determined. Subjects with SOFA ≥ 5 had a higher risk of NIV failure (odds ratio = 3.3, 95% CI 2.4-4.5). ICU mortality was higher in subjects with NIV failure (38.4%) compared with invasive mechanical ventilation subjects (31.3%, P = .018), and NIV failure was associated with increased ICU mortality (odds ratio = 11.4, 95% CI 6.5-20.1). An automatic and non-subjective algorithm based on CHAID decision-tree analysis can help to define the profile of patients with different risks of NIV failure, which might be a promising tool to assist in clinical decision making to avoid the possible complications associated with NIV failure. Copyright © 2017 by Daedalus Enterprises.
NASA Astrophysics Data System (ADS)
Lin, Erica; Li, Yaning; Ortiz, Christine; Boyce, Mary C.
2014-12-01
Geometrically structured interfaces in nature possess enhanced, and often surprising, mechanical properties, and provide inspiration for materials design. This paper investigates the mechanics of deformation and failure mechanisms of suture interface designs through analytical models and experiments on 3D printed polymer physical prototypes. Suture waveforms with generalized trapezoidal geometries (trapezoidal, rectangular, anti-trapezoidal, and triangular) are studied and characterized by several important geometric parameters: the presence or absence of a bonded tip region, the tip angle, and the geometry. It is shown that a wide range (in some cases as great as an order of magnitude) in stiffness, strength, and toughness is achievable dependent on tip bonding, tip angle, and geometry. Suture interfaces with a bonded tip region exhibit a higher initial stiffness due to the greater load bearing by the skeletal teeth, a double peak in the stress-strain curve corresponding to the failure of the bonded tip and the failure of the slanted interface region or tooth, respectively, and an additional failure and toughening mechanism due to the failure of the bonded tip. Anti-trapezoidal geometries promote the greatest amplification of properties for suture interfaces with a bonded tip due the large tip interface area. The tip angle and geometry govern the stress distributions in the teeth and the ratio of normal to shear stresses in the interfacial layers, which together determine the failure mechanism of the interface and/or the teeth. Rectangular suture interfaces fail by simple shearing of the interfaces. Trapezoidal and triangular suture interfaces fail by a combination of shear and tensile normal stresses in the interface, leading to plastic deformation, cavitation events, and subsequent stretching of interface ligaments with mostly elastic deformation in the teeth. Anti-trapezoidal suture interfaces with small tip angles have high stress concentrations in the teeth and fail catastrophically by tooth failure, whereas larger tip angles exhibit a shear failure of the interfaces. Therefore, larger tip angles and trapezoidal or triangular geometries promote graceful failure, and smaller tip angles and anti-trapezoidal geometries promote more brittle-like failure. This dependence is reminiscent of biological systems, which exhibit a range of failure behaviors with limited materials and varied geometry. Triangular geometries uniquely exhibit uniform stress distributions in its teeth and promote the greatest amplification of mechanical properties. In both the bonded and unbonded cases, the predictions from the presented analytical models and experimental results on 3D printed prototypes show excellent agreement. This validates the analytical models and allows for the models to be used as a tool for the design of new materials and interfaces with tailored mechanical behavior.
Ageing and degradation determines failure mode on sea urchin spines.
Merino, Monica; Vicente, Erika; Gonzales, Karen N; Torres, Fernando G
2017-09-01
Sea urchin spines are an example of a hard natural composite with mineral and organic phases. The role of the organic phase in the response to mechanical stress was assessed by promoting the degradation of such spines by exposing them to ageing and ultraviolet (UV) irradiation. Thermal and structural characterization of the irradiated samples show that this UV irradiation treatment promotes degradation of the organic and inorganic phase of spines. Uniaxial compression tests carried out on aged and UV irradiated samples showed that both treatments affected the mechanical properties of the spines. Scanning electron microscopy (SEM) images of failed specimens were used to analyze the failure mechanisms of the compressed spines. The analysis of the fracture surfaces showed that the failure mechanisms of spines were modified as a consequence of UV irradiation, leading in the last case to mostly brittle fracture surfaces. We suggest that the proteins responsible for the formation of calcite also determine the mechanical properties and the failure mode of spines. This system can be used as a model for the study of the failure modes of other natural and synthetic hard composites. Copyright © 2017 Elsevier B.V. All rights reserved.
Subcritical crack growth in SiNx thin-film barriers studied by electro-mechanical two-point bending
NASA Astrophysics Data System (ADS)
Guan, Qingling; Laven, Jozua; Bouten, Piet C. P.; de With, Gijsbertus
2013-06-01
Mechanical failure resulting from subcritical crack growth in the SiNx inorganic barrier layer applied on a flexible multilayer structure was studied by an electro-mechanical two-point bending method. A 10 nm conducting tin-doped indium oxide layer was sputtered as an electrical probe to monitor the subcritical crack growth in the 150 nm dielectric SiNx layer carried by a polyethylene naphthalate substrate. In the electro-mechanical two-point bending test, dynamic and static loads were applied to investigate the crack propagation in the barrier layer. As consequence of using two loading modes, the characteristic failure strain and failure time could be determined. The failure probability distribution of strain and lifetime under each loading condition was described by Weibull statistics. In this study, results from the tests in dynamic and static loading modes were linked by a power law description to determine the critical failure over a range of conditions. The fatigue parameter n from the power law reduces greatly from 70 to 31 upon correcting for internal strain. The testing method and analysis tool as described in the paper can be used to understand the limit of thin-film barriers in terms of their mechanical properties.
de Moura Xavier, José Carlos; de Andrade Azevedo, Irany; de Sousa Junior, Wilson Cabral; Nishikawa, Augusto
2013-02-01
Atmospheric pollutant monitoring constitutes a primordial activity in public policies concerning air quality. In São Paulo State, Brazil, the São Paulo State Environment Company (CETESB) maintains an automatic network which continuously monitors CO, SO(2), NO(x), O(3), and particulate matter concentrations in the air. The monitoring process accuracy is a fundamental condition for the actions to be taken by CETESB. As one of the support systems, a preventive maintenance program for the different analyzers used is part of the data quality strategy. Knowledge of the behavior of analyzer failure times could help optimize the program. To achieve this goal, the failure times of an ozone analyzer-considered a repairable system-were modeled by means of the nonhomogeneous Poisson process. The rate of occurrence of failures (ROCOF) was estimated for the intervals 0-70,800 h and 0-88,320 h, in which six and seven failures were observed, respectively. The results showed that the ROCOF estimate is influenced by the choice of the observation period, t(0) = 70,800 h and t(7) = 88,320 h in the cases analyzed. Identification of preventive maintenance actions, mainly when parts replacement occurs in the last interval of observation, is highlighted, justifying the alteration in the behavior of the inter-arrival times. The performance of a follow-up on each analyzer is recommended in order to record the impact of the performed preventive maintenance program on the enhancement of its useful life.
Danquechin Dorval, Antoine; Meredieu, Céline; Danjon, Frédéric
2016-01-01
Background and Aims Storms can cause huge damage to European forests. Even pole-stage trees with 80-cm rooting depth can topple. Therefore, good anchorage is needed for trees to survive and grow up from an early age. We hypothesized that root architecture is a predominant factor determining anchorage failure caused by strong winds. Methods We sampled 48 seeded or planted Pinus pinaster trees of similar aerial size from four stands damaged by a major storm 3 years before. The trees were gathered into three classes: undamaged, leaning and heavily toppled. After uprooting and 3D digitizing of their full root architectures, we computed the mechanical characteristics of the main components of the root system from our morphological measurements. Key Results Variability in root architecture was quite large. A large main taproot, either short and thick or long and thin, and guyed by a large volume of deep roots, was the major component that prevented stem leaning. Greater shallow root flexural stiffness mainly at the end of the zone of rapid taper on the windward side also prevented leaning. Toppling in less than 90-cm-deep soil was avoided in trees with a stocky taproots or with a very big leeward shallow root. Toppled trees also had a lower relative root biomass – stump excluded – than straight trees. Conclusions It was mainly the flexural stiffness of the central part of the root system that secured anchorage, preventing a weak displacement of the stump. The distal part of the longest taproot and attached deep roots may be the only parts of the root system contributing to anchorage through their maximum tensile load. Several designs provided good anchorage, depending partly on available soil depth. Pole-stage trees are in-between the juvenile phase when they fail by toppling and the mature phase when they fail by uprooting. PMID:27456136
Hiemstra, Jessica A; Lee, Dong I; Chakir, Khalid; Gutiérrez-Aguilar, Manuel; Marshall, Kurt D; Zgoda, Pamela J; Cruz Rivera, Noelany; Dozier, Daniel G; Ferguson, Brian S; Heublein, Denise M; Burnett, John C; Scherf, Carolin; Ivey, Jan R; Minervini, Gianmaria; McDonald, Kerry S; Baines, Christopher P; Krenz, Maike; Domeier, Timothy L; Emter, Craig A
2016-04-20
Cyclic guanosine monophosphate-protein kinase G-phosphodiesterase 5 signaling may be disturbed in heart failure (HF) with preserved ejection fraction, contributing to cardiac remodeling and dysfunction. The purpose of this study was to manipulate cyclic guanosine monophosphate signaling using the dipeptidyl-peptidase 4 inhibitor saxagliptin and phosphodiesterase 5 inhibitor tadalafil. We hypothesized that preservation of cyclic guanosine monophosphate cGMP signaling would attenuate pathological cardiac remodeling and improve left ventricular (LV) function. We assessed LV hypertrophy and function at the organ and cellular level in aortic-banded pigs. Concentric hypertrophy was equal in all groups, but LV collagen deposition was increased in only HF animals. Prevention of fibrotic remodeling by saxagliptin and tadalafil was correlated with neuropeptide Y plasma levels. Saxagliptin better preserved integrated LV systolic and diastolic function by maintaining normal LV chamber volumes and contractility (end-systolic pressure-volume relationship, preload recruitable SW) while preventing changes to early/late diastolic longitudinal strain rate. Function was similar to the HF group in tadalafil-treated animals including increased LV contractility, reduced chamber volume, and decreased longitudinal, circumferential, and radial mechanics. Saxagliptin and tadalafil prevented a negative cardiomyocyte shortening-frequency relationship observed in HF animals. Saxagliptin increased phosphodiesterase 5 activity while tadalafil increased cyclic guanosine monophosphate levels; however, neither drug increased downstream PKG activity. Early mitochondrial dysfunction, evident as decreased calcium-retention capacity and Complex II-dependent respiratory control, was present in both HF and tadalafil-treated animals. Both saxagliptin and tadalafil prevented increased LV collagen deposition in a manner related to the attenuation of increased plasma neuropeptide Y levels. Saxagliptin appears superior for treating heart failure with preserved ejection fraction, considering its comprehensive effects on integrated LV systolic and diastolic function. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
29 CFR 1601.25 - Failure of conciliation; notice.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 4 2010-07-01 2010-07-01 false Failure of conciliation; notice. 1601.25 Section 1601.25 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION PROCEDURAL REGULATIONS Procedure for the Prevention of Unlawful Employment Practices Procedure to Rectify Unlawful...
29 CFR 1601.25 - Failure of conciliation; notice.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 4 2011-07-01 2011-07-01 false Failure of conciliation; notice. 1601.25 Section 1601.25 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION PROCEDURAL REGULATIONS Procedure for the Prevention of Unlawful Employment Practices Procedure to Rectify Unlawful...
Analysis of minimum rail size in heavy axle load environment
DOT National Transportation Integrated Search
2013-04-15
The effects of increasing axle loads on rail integrity are examined in this paper. In the present context, rail integrity refers to the prevention and control of rail failures. Rail failures usually occur because cracks or defects develop and grow fr...
Learned Helplessness: A Model to Understand and Overcome a Child's Extreme Reaction to Failure.
ERIC Educational Resources Information Center
Balk, David
1983-01-01
The author reviews literature on childrens' reactions to perceived failure and offers "learned helplessness" as a model to explain why a child who makes a mistake gives up. Suggestions for preventing these reactions are given. (Author/JMK)
A miniature mechanical ventilator for newborn mice.
Kolandaivelu, K; Poon, C S
1998-02-01
Transgenic/knockout mice with pre-defined mutations have become increasingly popular in biomedical research as models of human diseases. In some instances, the resulting mutation may cause cardiorespiratory distress in the neonatal or adult animals and may necessitate resuscitation. Here we describe the design and testing of a miniature and versatile ventilator that can deliver varying ventilatory support modes, including conventional mechanical ventilation and high-frequency ventilation, to animals as small as the newborn mouse. With a double-piston body chamber design, the device circumvents the problem of air leakage and obviates the need for invasive procedures such as endotracheal intubation, which are particularly important in ventilating small animals. Preliminary tests on newborn mice as early as postnatal day O demonstrated satisfactory restoration of pulmonary ventilation and the prevention of respiratory failure in mutant mice that are prone to respiratory depression. This device may prove useful in the postnatal management of transgenic/knockout mice with genetically inflicted respiratory disorders.
Preterm birth research: from disillusion to the search for new mechanisms.
Buekens, P; Klebanoff, M
2001-07-01
No intervention has been shown to decrease the rate of preterm birth. There was thus a need for a new research agenda. The new emphasis is on social and biological mechanisms, including the impact on stress of racism and poverty, and gene-environment interactions. New markers are also under study, and pertain mostly to infection and inflammation. The impact on preterm birth of broad contextual factors, such as universal social protection, will need to be explored further. The recent trends toward increased rates of preterm births deserve much attention. New policies and interventions to decrease medically indicated preterm births should be urgently developed and evaluated. The failure to prevent preterm deliveries has been so disappointing that there is a risk that high rates of preterm births will be seen as unavoidable. The research programme launched by March of Dimes is a timely effort to foster new enthusiasm, to test new ideas and to generate new hypotheses.
Bariatric Surgery and Stone Disease
NASA Astrophysics Data System (ADS)
Lieske, John C.; Kumar, Rajiv
2008-09-01
Bariatric surgery is an effective treatment strategy for patients with morbid obesity that can result in effective weight loss, resolution of diabetes mellitus and other weight related complications, and even improved mortality. However, it also appears that hyperoxaluria is common after modern bariatric surgery, perhaps occurring in up to 50% of patients after Rouxen-Y gastric bypass. Although increasing numbers of patients are being seen with calcium oxalate kidney stones after bariatric surgery, and even a few with oxalosis and renal failure, the true risk of these outcomes remains unknown. The mechanisms that contribute to this enteric hyperoxaluria are also incompletely defined, although fat malabsorption may be an important component. Since increasing numbers of these procedures are likely to be performed in the coming years, further study regarding the prevalence and mechanisms of hyperoxaluria and kidney stones after bariatric surgery is needed to devise effective methods of treatment in order to prevent such complications.
Severe acquired anaemia in Africa: new concepts.
van Hensbroek, Michael B; Jonker, Femkje; Bates, Imelda
2011-09-01
Severe anaemia is common in Africa. It has a high mortality and particularly affects young children and pregnant women. Recent research provides new insights into the mechanisms and causes of severe acquired anaemia and overturns accepted dogma. Deficiencies of vitamin B12 and vitamin A, but not of iron or folic acid, are associated with severe anaemia. Bacterial infections and, in very young children, hookworm infections are also common in severe anaemia. Irrespective of the aetiology, the mechanism causing severe anaemia is often red cell production failure. Severe anaemia in Africa is therefore a complex multi-factorial syndrome, which, even in an individual patient, is unlikely to be amenable to a single intervention. Policies and practices concerning anaemia diagnosis, treatment and prevention need to be substantially revised if we are to make a significant impact on the huge burden of severe anaemia in Africa. © 2011 Blackwell Publishing Ltd.
Contemporary approach to stroke prevention in atrial fibrillation: Risks, benefits, and new options.
Stock, Jonathan; Malm, Brian J
2018-04-04
Atrial fibrillation is a common diagnosis affecting nearly 3 million adults in the United States. Morbidity and mortality in these patients is driven largely by the associated increased risk of thromboembolic complications, especially stroke. Atrial fibrillation is a stronger risk factor than hypertension, coronary disease, or heart failure and is associated with an approximately five-fold increased risk. Mitigating stroke risk can be challenging and requires accurate assessment of stroke risk factors and careful selection of appropriate therapy. Anticoagulation, including the more recently introduced direct oral anticoagulants, is the standard of care for most patients. In addition, emerging non-pharmacologic mechanical interventions are playing an expanding role in reducing stroke risk in select patients. In this review we highlight the current approach to stroke risk stratification in atrial fibrillation and discuss in detail the mechanism, risks, and benefits of current and evolving therapies. Copyright © 2018 Elsevier Inc. All rights reserved.
Physics of Cell Adhesion Failure and Human Diseases
NASA Astrophysics Data System (ADS)
Family, Fereydoon
Emergent phenomena in living systems, including your ability to read these lines, do not obviously follow as a consequence of the fundamental laws of physics. Understanding the physics of living systems clearly falls outside the conventional boundaries of scientific disciplines and requires a collaborative, multidisciplinary approach. Here I will discuss how theoretical and computational techniques from statistical physics can be used to make progress in explaining the physical mechanisms that underlie complex biological phenomena, including major diseases. In the specific cases of macular degeneration and cancer that we have studied recently, we find that the breakdown of the mechanical stability in the local tissue structure caused by weakening of the cell-cell adhesion plays a key role in the initiation and progression of the disease. This finding can help in the development of new therapies that would prevent or halt the initiation and progression of these diseases.
Redox signaling in cardiovascular health and disease
Madamanchi, Nageswara R.; Runge, Marschall S.
2013-01-01
Spatiotemporal regulation of the activity of a vast array of intracellular proteins and signaling pathways by reactive oxygen species (ROS) governs normal cardiovascular function. However, data from experimental and animal studies strongly support that dysregulated redox signaling, resulting from hyper-activation of various cellular oxidases or mitochondrial dysfunction, is integral to the pathogenesis and progression of cardiovascular disease (CVD). In this review, we address how redox signaling modulates the protein function, the various sources of increased oxidative stress in CVD, and the labyrinth of redox-sensitive molecular mechanisms involved in the development of atherosclerosis, hypertension, cardiac hypertrophy and heart failure, and ischemia–reperfusion injury. Advances in redox biology and pharmacology for inhibiting ROS production in specific cell types and subcellular organelles combined with the development of nanotechnology-based new in vivo imaging systems and targeted drug delivery mechanisms may enable fine-tuning of redox signaling for the treatment and prevention of CVD. PMID:23583330
Postoperative respiratory muscle dysfunction: pathophysiology and preventive strategies.
Sasaki, Nobuo; Meyer, Matthew J; Eikermann, Matthias
2013-04-01
Postoperative pulmonary complications are responsible for significant increases in hospital cost as well as patient morbidity and mortality; respiratory muscle dysfunction represents a contributing factor. Upper airway dilator muscles functionally resist the upper airway collapsing forces created by the respiratory pump muscles. Standard perioperative medications (anesthetics, sedatives, opioids, and neuromuscular blocking agents), interventions (patient positioning, mechanical ventilation, and surgical trauma), and diseases (lung hyperinflation, obesity, and obstructive sleep apnea) have differential effects on the respiratory muscle subgroups. These effects on the upper airway dilators and respiratory pump muscles impair their coordination and function and can result in respiratory failure. Perioperative management strategies can help decrease the incidence of postoperative respiratory muscle dysfunction. Such strategies include minimally invasive procedures rather than open surgery, early and optimal mobilizing of respiratory muscles while on mechanical ventilation, judicious use of respiratory depressant anesthetics and neuromuscular blocking agents, and noninvasive ventilation when possible.
Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E
2008-07-01
The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.
Addressing Production System Failures Using Multi-agent Control
NASA Astrophysics Data System (ADS)
Gautam, Rajesh; Miyashita, Kazuo
Output in high-volume production facilities is limited by bottleneck machines. We propose a control mechanism by modeling workstations as agents that pull jobs from other agents based on their current WIP level and requirements. During failures, when flows of some jobs are disrupted, the agents pull alternative jobs to maintain utilization of their capacity at a high level. In this paper, we empirically demonstrate that the proposed mechanism can react to failures more appropriately than other control mechanisms using a benchmark problem of a semiconductor manufacturing process.
A Framework for Creating a Function-based Design Tool for Failure Mode Identification
NASA Technical Reports Server (NTRS)
Arunajadai, Srikesh G.; Stone, Robert B.; Tumer, Irem Y.; Clancy, Daniel (Technical Monitor)
2002-01-01
Knowledge of potential failure modes during design is critical for prevention of failures. Currently industries use procedures such as Failure Modes and Effects Analysis (FMEA), Fault Tree analysis, or Failure Modes, Effects and Criticality analysis (FMECA), as well as knowledge and experience, to determine potential failure modes. When new products are being developed there is often a lack of sufficient knowledge of potential failure mode and/or a lack of sufficient experience to identify all failure modes. This gives rise to a situation in which engineers are unable to extract maximum benefits from the above procedures. This work describes a function-based failure identification methodology, which would act as a storehouse of information and experience, providing useful information about the potential failure modes for the design under consideration, as well as enhancing the usefulness of procedures like FMEA. As an example, the method is applied to fifteen products and the benefits are illustrated.
High-throughput sequencing: a failure mode analysis.
Yang, George S; Stott, Jeffery M; Smailus, Duane; Barber, Sarah A; Balasundaram, Miruna; Marra, Marco A; Holt, Robert A
2005-01-04
Basic manufacturing principles are becoming increasingly important in high-throughput sequencing facilities where there is a constant drive to increase quality, increase efficiency, and decrease operating costs. While high-throughput centres report failure rates typically on the order of 10%, the causes of sporadic sequencing failures are seldom analyzed in detail and have not, in the past, been formally reported. Here we report the results of a failure mode analysis of our production sequencing facility based on detailed evaluation of 9,216 ESTs generated from two cDNA libraries. Two categories of failures are described; process-related failures (failures due to equipment or sample handling) and template-related failures (failures that are revealed by close inspection of electropherograms and are likely due to properties of the template DNA sequence itself). Preventative action based on a detailed understanding of failure modes is likely to improve the performance of other production sequencing pipelines.
Renal function monitoring in heart failure - what is the optimal frequency? A narrative review.
Al-Naher, Ahmed; Wright, David; Devonald, Mark Alexander John; Pirmohamed, Munir
2018-01-01
The second most common cause of hospitalization due to adverse drug reactions in the UK is renal dysfunction due to diuretics, particularly in patients with heart failure, where diuretic therapy is a mainstay of treatment regimens. Therefore, the optimal frequency for monitoring renal function in these patients is an important consideration for preventing renal failure and hospitalization. This review looks at the current evidence for optimal monitoring practices of renal function in patients with heart failure according to national and international guidelines on the management of heart failure (AHA/NICE/ESC/SIGN). Current guidance of renal function monitoring is in large part based on expert opinion, with a lack of clinical studies that have specifically evaluated the optimal frequency of renal function monitoring in patients with heart failure. Furthermore, there is variability between guidelines, and recommendations are typically nonspecific. Safer prescribing of diuretics in combination with other antiheart failure treatments requires better evidence for frequency of renal function monitoring. We suggest developing more personalized monitoring rather than from the current medication-based guidance. Such flexible clinical guidelines could be implemented using intelligent clinical decision support systems. Personalized renal function monitoring would be more effective in preventing renal decline, rather than reacting to it. © 2017 The Authors. British Journal of Clinical Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.
Dilated cardiomyopathy and severe heart failure. An update for pediatricians.
Caviedes Bottner, Paola; Córdova Fernández, Tamara; Larraín Valenzuela, Marcos; Cruces Romero Presentación de Casos Clínicos, Pablo
2018-06-01
Dilated cardiomyopathy is the main cause of heart failure leading to heart transplant. Its prognosis is variable and depends on the etiology, the patient's age at onset, and the severity. The management of dilated cardiomyopathy is aimed at minimizing symptoms and preventing disease progression; it requires a comprehensive screening for comorbidities and the prevention of complications to improve the overall status of these children and mitigate their prognosis. Here we present a review oriented at the multidisciplinary management that pediatricians should consider when seeing these patients. Sociedad Argentina de Pediatría.
O'Donnell, J; Hawkins, J D; Catalano, R F; Abbott, R D; Day, L E
1995-01-01
A six-year, school-based prevention program, which modified classroom teacher practices, offered parent training, and provided child social skills training, was evaluated for its effects on school failure, drug abuse, and delinquency among low-income urban children. Compared to a low-income control group, children in the intervention group showed enhanced school commitment and class participation. The girls in the group also evidenced lower rates of substance use initiation, while the boys exhibited increased social and school work skills.
Mechanisms of Diagonal-Shear Failure in Reinforced Concrete Beams analyzed by AE-SiGMA
NASA Astrophysics Data System (ADS)
Ohno, Kentaro; Shimozono, Shinichiro; Sawada, Yosuke; Ohtsu, Masayasu
Serious shear failures in reinforced concrete (RC) structures were reported in the Hanshin-Awaji Earthquake. In particular, it was demonstrated that a diagonal-shear failure could lead to disastrous damage. However, mechanisms of the diagonal-shear failure in RC beams have not been completely clarified yet. In this study, the diagonal-shear failure in RC beams is investigated, applying acoustic emission (AE) method. To identify source mechanisms of AE signals, SiGMA (Simplified Green's functions for Moment tensor Analysis) procedure was applied. Prior to four-point bending tests of RC beams, theoretical waveforms were calculated to determine the optimal arrangement of AE sensors. Then, cracking mechanisms in experiments were investigated by applying the SiGMA procedure to AE waveforms. From results of the SiGMA analysis, dominant motions of micro-cracks are found to be of shear crack in all the loading stages. As the load increased, the number of tensile cracks increased and eventually the diagonal-shear failure occurred in the shear span. Prior to final failure, AE cluster of micro-cracks was intensely observed in the shear span. To classify AE sources into tensile and shear cracks, AE parameter analysis was also applied. As a result, most of AE hits are classified into tensile cracks. The difference between results obtained by the AE parameter analysis and by the SiGMA analysis is investigated and discussed.