Phase Field Fracture Mechanics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, Brett Anthony
For this assignment, a newer technique of fracture mechanics using a phase field approach, will be examined and compared with experimental data for a bend test and a tension test. The software being used is Sierra Solid Mechanics, an implicit/explicit finite element code developed at Sandia National Labs in Albuquerque, New Mexico. The bend test experimental data was also obtained at Sandia Labs while the tension test data was found in a report online from Purdue University.
2017-12-08
Inside the Prototype Development Laboratory at NASA's Kennedy Space Center in Florida, engineers and technicians hold a banner marking the successful delivery of a liquid oxygen test tank called Tardis. From left, are Todd Steinrock, chief, Fabrication and Development Branch, Prototype Development Lab; David McLaughlin, electrical engineering technician; Phil Stroda, mechanical engineering technician; Perry Dickey, lead electrical engineering technician; and Harold McAmis, lead mechanical engineering technician. Engineers and technicians worked together to develop the tank and build it at the lab to support cryogenic testing at Johnson Space Center's White Sands Test Facility in Las Cruces, New Mexico. The 12-foot-tall, 3,810-pound aluminum tank will be shipped to White Sands for testing.
Mechanics of Ballast Compaction. Volume 4 : Lab. Invest. the Effects of Field Compaction Mechanisms
DOT National Transportation Integrated Search
1982-03-01
This report describes a preliminary series of laboratory tests which attempt to simulate some of the effects of maintenance procedures and traffic on the physical state of ballast as measured by the ballast density test, plate load test, and lateral ...
The NASA Langley Isolator Dynamics Research Lab
NASA Technical Reports Server (NTRS)
Middleton, Troy F.; Balla, Robert J.; Baurle, Robert A.; Humphreys, William M.; Wilson, Lloyd G.
2010-01-01
The Isolator Dynamics Research Lab (IDRL) is under construction at the NASA Langley Research Center in Hampton, Virginia. A unique test apparatus is being fabricated to support both wall and in-stream measurements for investigating the internal flow of a dual-mode scramjet isolator model. The test section is 24 inches long with a 1-inch by 2-inch cross sectional area and is supplied with unheated, dry air through a Mach 2.5 converging-diverging nozzle. The test section is being fabricated with two sets (glass and metallic) of interchangeable sidewalls to support flow visualization and laser-based measurement techniques as well as static pressure, wall temperature, and high frequency pressure measurements. During 2010, a CFD code validation experiment will be conducted in the lab in support of NASA s Fundamental Aerodynamics Program. This paper describes the mechanical design of the Isolator Dynamics Research Lab test apparatus and presents a summary of the measurement techniques planned for investigating the internal flow field of a scramjet isolator model.
18. VIEW OF THE GENERAL CHEMISTRY LAB. THE LABORATORY PROVIDED ...
18. VIEW OF THE GENERAL CHEMISTRY LAB. THE LABORATORY PROVIDED GENERAL ANALYTICAL AND STANDARDS CALIBRATION, AS WELL AS DEVELOPMENT OPERATIONS INCLUDING WASTE TECHNOLOGY DEVELOPMENT AND DEVELOPMENT AND TESTING OF MECHANICAL SYSTEMS FOR WEAPONS SYSTEMS. (4/4/66) - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO
NASA Astrophysics Data System (ADS)
Pardoen, Thomas; Colla, Marie-Sthéphane; Idrissi, Hosni; Amin-Ahmadi, Behnam; Wang, Binjie; Schryvers, Dominique; Bhaskar, Umesh K.; Raskin, Jean-Pierre
2016-03-01
A nanomechanical on-chip test platform has recently been developed to deform under a variety of loading conditions freestanding thin films, ribbons and nanowires involving submicron dimensions. The lab-on-chip involves thousands of elementary test structures from which the elastic modulus, strength, strain hardening, fracture, creep properties can be extracted. The technique is amenable to in situ transmission electron microscopy (TEM) investigations to unravel the fundamental underlying deformation and fracture mechanisms that often lead to size-dependent effects in small-scale samples. The method allows addressing electrical and magnetic couplings as well in order to evaluate the impact of large mechanical stress levels on different solid-state physics phenomena. We had the chance to present this technique in details to Jacques Friedel in 2012 who, unsurprisingly, made a series of critical and very relevant suggestions. In the spirit of his legacy, the paper will address both mechanics of materials related phenomena and couplings with solids state physics issues.
TARDEC Overview: Ground Vehicle Power and Mobility
2011-02-04
Fuel & Water Distribution • Force Sustainment • Construction Equipment • Bridging • Assured Mobility Systems Robotics • TALON • PackBot • MARCbot...Equipment • Mechanical Countermine Equipment • Tactical Bridging Intelligent Ground Systems • Autonomous Robotics Systems • Safe Operations...Test Cell • Hybrid Electric Reconfigurable Moveable Integration Testbed (HERMIT) • Electro-chemical Analysis and Research Lab (EARL) • Battery Lab • Air
Zheng, Xufeng; Fu, Nan; Duan, Manlei; Woo, Meng Wai; Selomulya, Cordelia; Chen, Xiao Dong
2015-10-01
Reconstituted skim milk (RSM) is a reputed protective carrier for improving the survival ratio of lactic acid bacteria (LAB) after spray drying; however the underlying mechanisms of the prominent protection remains unclear. In this study, the inactivation histories of two LAB strains during droplet drying with four carriers were experimentally determined, and the effects of droplet drying parameters on LAB inactivation were investigated. For the first time, the possible contribution of each RSM components to the maintenance of LAB viability during drying was discussed. Rapid inactivation of LAB cells only started at the later stage of drying, where RSM could maintain viability better upon both high droplet temperature and low moisture content than the other three carriers tested. Such protective effects was attributed to calcium and milk proteins rather than lactose. Upon the rapidly increasing droplet temperature at the later stage, calcium might enhance the heat resistance of LAB cells, whereas proteins might lead to a mild temperature variation rate which was beneficial to cell survival. LAB cells dried in the reconstituted whole milk showed the most advanced transition of rapid viability loss, with transition temperature at around 60°C, in contrast to 65-70°C in lactose and MRS carriers and 75°C in the RSM carrier. The detrimental effects could be due to the high level of milk fat content. The proposed effects of each RSM components on LAB viability would be useful for constructing more powerful protectants for production of active dry LAB cells via spray drying. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lab-on-a-brane: nanofibrous polymer membranes to recreate organ-capillary interfaces
NASA Astrophysics Data System (ADS)
Budhwani, Karim I.; Thomas, Vinoy; Sethu, Palaniappan
2016-03-01
Drug discovery is a complex and time consuming process involving significant basic research and preclinical evaluation prior to testing in patients. Preclinical studies rely extensively on animal models which often fail in human trials. Biomimetic microphysiological systems (MPS) using human cells can be a promising alternative to animal models; where critical interactions between different organ systems are recreated to provide physiologically relevant in vitro human models. Central here are blood-vessel networks, the interface controlling transport of cellular and biomolecular components between the circulating fluid and underlying tissue. Here we present a novel lab-on-a-brane (or lab-on-a-membrane) nanofluidics MPS that combines the elegance of lab-on-a-chip with the more realistic morphology of 3D fibrous tissue-engineering constructs. Our blood-vessel lab-on-a-brane effectively simulates in vivo vessel-tissue interface for evaluating transendothelial transport in various pharmacokinetic and nanomedicine applications. Attributes of our platform include (a) nanoporous barrier interface enabling transmembrane molecular transport, (b) transformation of substrate into nanofibrous 3D tissue matrix, (c) invertible-sandwich architecture, and (d) simple co-culture mechanism for endothelial and smooth muscle layers to accurately mimic arterial anatomy. Structural, mechanical, and transport characterization using scanning electron microscopy, stress/strain analysis, infrared spectroscopy, immunofluorescence, and FITC-Dextran hydraulic permeability confirm viability of this in vitro system. Thus, our lab-on-a-brane provides an effective and efficient, yet considerably inexpensive, physiologically relevant alternative for pharmacokinetic evaluation; possibly reducing animals used in preclinical testing, costs from false starts, and time-to-market. Furthermore, it can be configured in multiple simultaneous arrays for personalized and precision medicine applications and for evaluating localized and targeted therapeutic delivery.
The LabTube - a novel microfluidic platform for assay automation in laboratory centrifuges.
Kloke, A; Fiebach, A R; Zhang, S; Drechsel, L; Niekrawietz, S; Hoehl, M M; Kneusel, R; Panthel, K; Steigert, J; von Stetten, F; Zengerle, R; Paust, N
2014-05-07
Assay automation is the key for successful transformation of modern biotechnology into routine workflows. Yet, it requires considerable investment in processing devices and auxiliary infrastructure, which is not cost-efficient for laboratories with low or medium sample throughput or point-of-care testing. To close this gap, we present the LabTube platform, which is based on assay specific disposable cartridges for processing in laboratory centrifuges. LabTube cartridges comprise interfaces for sample loading and downstream applications and fluidic unit operations for release of prestored reagents, mixing, and solid phase extraction. Process control is achieved by a centrifugally-actuated ballpen mechanism. To demonstrate the workflow and functionality of the LabTube platform, we show two LabTube automated sample preparation assays from laboratory routines: DNA extractions from whole blood and purification of His-tagged proteins. Equal DNA and protein yields were observed compared to manual reference runs, while LabTube automation could significantly reduce the hands-on-time to one minute per extraction.
Integrating Multiple On-line Knowledge Bases for Disease-Lab Test Relation Extraction.
Zhang, Yaoyun; Soysal, Ergin; Moon, Sungrim; Wang, Jingqi; Tao, Cui; Xu, Hua
2015-01-01
A computable knowledge base containing relations between diseases and lab tests would be a great resource for many biomedical informatics applications. This paper describes our initial step towards establishing a comprehensive knowledge base of disease and lab tests relations utilizing three public on-line resources. LabTestsOnline, MedlinePlus and Wikipedia are integrated to create a freely available, computable disease-lab test knowledgebase. Disease and lab test concepts are identified using MetaMap and relations between diseases and lab tests are determined based on source-specific rules. Experimental results demonstrate a high precision for relation extraction, with Wikipedia achieving the highest precision of 87%. Combining the three sources reached a recall of 51.40%, when compared with a subset of disease-lab test relations extracted from a reference book. Moreover, we found additional disease-lab test relations from on-line resources, indicating they are complementary to existing reference books for building a comprehensive disease and lab test relation knowledge base.
Developing a Virtual Rock Deformation Laboratory
NASA Astrophysics Data System (ADS)
Zhu, W.; Ougier-simonin, A.; Lisabeth, H. P.; Banker, J. S.
2012-12-01
Experimental rock physics plays an important role in advancing earthquake research. Despite its importance in geophysics, reservoir engineering, waste deposits and energy resources, most geology departments in U.S. universities don't have rock deformation facilities. A virtual deformation laboratory can serve as an efficient tool to help geology students naturally and internationally learn about rock deformation. Working with computer science engineers, we built a virtual deformation laboratory that aims at fostering user interaction to facilitate classroom and outreach teaching and learning. The virtual lab is built to center around a triaxial deformation apparatus in which laboratory measurements of mechanical and transport properties such as stress, axial and radial strains, acoustic emission activities, wave velocities, and permeability are demonstrated. A student user can create her avatar to enter the virtual lab. In the virtual lab, the avatar can browse and choose among various rock samples, determine the testing conditions (pressure, temperature, strain rate, loading paths), then operate the virtual deformation machine to observe how deformation changes physical properties of rocks. Actual experimental results on the mechanical, frictional, sonic, acoustic and transport properties of different rocks at different conditions are compiled. The data acquisition system in the virtual lab is linked to the complied experimental data. Structural and microstructural images of deformed rocks are up-loaded and linked to different deformation tests. The integration of the microstructural image and the deformation data allows the student to visualize how forces reshape the structure of the rock and change the physical properties. The virtual lab is built using the Game Engine. The geological background, outstanding questions related to the geological environment, and physical and mechanical concepts associated with the problem will be illustrated on the web portal. In addition, some web based data collection tools are available to collect student feedback and opinions on their learning experience. The virtual laboratory is designed to be an online education tool that facilitates interactive learning.; Virtual Deformation Laboratory
recognized in are Accreditation of Testing Labs, Calibration Labs, Medical Labs, Inspection Bodies Testing Labs, Calibration Labs, Medical Labs, Inspection Bodies, Certification of QMS, EMS and FSMS. 4 Jul
A novel PMT test system based on waveform sampling
NASA Astrophysics Data System (ADS)
Yin, S.; Ma, L.; Ning, Z.; Qian, S.; Wang, Y.; Jiang, X.; Wang, Z.; Yu, B.; Gao, F.; Zhu, Y.; Wang, Z.
2018-01-01
Comparing with the traditional test system based on a QDC and TDC and scaler, a test system based on waveform sampling is constructed for signal sampling of the 8"R5912 and the 20"R12860 Hamamatsu PMT in different energy states from single to multiple photoelectrons. In order to achieve high throughput and to reduce the dead time in data processing, the data acquisition software based on LabVIEW is developed and runs with a parallel mechanism. The analysis algorithm is realized in LabVIEW and the spectra of charge, amplitude, signal width and rising time are analyzed offline. The results from Charge-to-Digital Converter, Time-to-Digital Converter and waveform sampling are discussed in detailed comparison.
An automated calibration laboratory - Requirements and design approach
NASA Technical Reports Server (NTRS)
O'Neil-Rood, Nora; Glover, Richard D.
1990-01-01
NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.
Validity of Selected Lab and Field Tests of Physical Working Capacity.
ERIC Educational Resources Information Center
Burke, Edmund J.
The validity of selected lab and field tests of physical working capacity was investigated. Forty-four male college students were administered a series of lab and field tests of physical working capacity. Lab tests include a test of maximum oxygen uptake, the PWC 170 test, the Harvard Step Test, the Progressive Pulse Ratio Test, Margaria Test of…
A compact ball screw based electromagnetic energy harvester for railroad application
NASA Astrophysics Data System (ADS)
Pan, Yu; Lin, Teng; Liu, Cheng; Yu, Jie; Zuo, Jianyong; Zuo, Lei
2018-03-01
To enable the smart technologies, such as the positive train controls, rail damage detection and track health monitoring on the railroad side, the electricity is required and in needed. In this paper, we proposed a novel ball-screw based electromagnetic energy harvester for railway track with mechanical-motion-rectifier (MMR) mechanism, to harvest the energy that usually dissipated and wasted during train induced track vibration. Ball screw based design reduces backlash during motion transmission, and MMR nonlinear characteristics with one way clutches makes the harvester convert the bi-direction track vibration into a generator's unidirectional rotation, which improves the transmission reliability and increases the energy harvesting efficiency. A systematic model combining train-rail-harvester was established to analyze the dynamic characteristic of the proposed railway energy, and lab and in-field tests were carried out to experimentally characterize the proposed energy harvester. In lab bench test showed the proposed harvester reached a 70% mechanical efficiency with a high sensitivity to the environment vibration. In filed test showed that a peak 7.8W phase power was achieved when a two marshaling type A metro train passed by with a 30 km/h.
Behind the Scenes at Berkeley Lab - The Mechanical Fabrication Facility
Wells, Russell; Chavez, Pete; Davis, Curtis; Bentley, Brian
2018-04-16
Part of the Behind the Scenes series at Berkeley Lab, this video highlights the lab's mechanical fabrication facility and its exceptional ability to produce unique tools essential to the lab's scientific mission. Through a combination of skilled craftsmanship and precision equipment, machinists and engineers work with scientists to create exactly what's needed - whether it's measured in microns or meters.
Blood Count Tests - Multiple Languages
... window. Arabic (العربية) Expand Section Your Lab Tests - English PDF Your Lab Tests - العربية (Arabic) PDF American ... Cantonese dialect) (繁體中文) Expand Section Your Lab Tests - English PDF Your Lab Tests - 繁體中文 (Chinese, Traditional (Cantonese ...
Lactic acid bacteria inhibit TH2 cytokine production by mononuclear cells from allergic patients.
Pochard, Pierre; Gosset, Philippe; Grangette, Corinne; Andre, Claude; Tonnel, André-Bernard; Pestel, Joël; Mercenier, Annick
2002-10-01
Among factors potentially involved in the increased prevalence of allergic diseases, modification of the intestinal bacteria flora or lack of bacterial stimulation during childhood has been proposed. Lactic acid bacteria (LAB) present in fermented foods or belonging to the natural intestinal microflora were shown to exert beneficial effects on human health. Recent reports have indicated their capacity to reduce allergic symptoms. The purpose of this investigation was to determine the effect of LAB on the production of type 2 cytokines, which characterize allergic diseases. PBMCs from patients allergic to house dust mite versus those from healthy donors were stimulated for 48 hours with the related Dermatophagoides pteronyssinus allergen or with a staphylococcal superantigen. The effect of LAB preincubation was assessed by measuring the type 2 cytokine production by means of specific ELISA. The tested gram-positive LAB were shown to inhibit the secretion of T(H)2 cytokines (IL-4 and IL-5). This effect was dose dependent and was observed irrespective of the LAB strain used. No significant inhibition was induced by the control, gram-negative Escherichia coli TG1. Interestingly, LAB reduced the T(H)2 cytokine production from allergic PBMCs specifically restimulated with the related allergen. The inhibition mechanism was shown to be dependent on antigen-presenting cells (ie, monocytes) and on the involvement of IL-12 and IFN-gamma. The tested LAB strains were demonstrated to exhibit an anti-T(H)2 activity, and thus different strains of this family might be useful in the prevention of allergic diseases.
Reducing unnecessary lab testing in the ICU with artificial intelligence.
Cismondi, F; Celi, L A; Fialho, A S; Vieira, S M; Reti, S R; Sousa, J M C; Finkelstein, S N
2013-05-01
To reduce unnecessary lab testing by predicting when a proposed future lab test is likely to contribute information gain and thereby influence clinical management in patients with gastrointestinal bleeding. Recent studies have demonstrated that frequent laboratory testing does not necessarily relate to better outcomes. Data preprocessing, feature selection, and classification were performed and an artificial intelligence tool, fuzzy modeling, was used to identify lab tests that do not contribute an information gain. There were 11 input variables in total. Ten of these were derived from bedside monitor trends heart rate, oxygen saturation, respiratory rate, temperature, blood pressure, and urine collections, as well as infusion products and transfusions. The final input variable was a previous value from one of the eight lab tests being predicted: calcium, PTT, hematocrit, fibrinogen, lactate, platelets, INR and hemoglobin. The outcome for each test was a binary framework defining whether a test result contributed information gain or not. Predictive modeling was applied to recognize unnecessary lab tests in a real world ICU database extract comprising 746 patients with gastrointestinal bleeding. Classification accuracy of necessary and unnecessary lab tests of greater than 80% was achieved for all eight lab tests. Sensitivity and specificity were satisfactory for all the outcomes. An average reduction of 50% of the lab tests was obtained. This is an improvement from previously reported similar studies with average performance 37% by [1-3]. Reducing frequent lab testing and the potential clinical and financial implications are an important issue in intensive care. In this work we present an artificial intelligence method to predict the benefit of proposed future laboratory tests. Using ICU data from 746 patients with gastrointestinal bleeding, and eleven measurements, we demonstrate high accuracy in predicting the likely information to be gained from proposed future lab testing for eight common GI related lab tests. Future work will explore applications of this approach to a range of underlying medical conditions and laboratory tests. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Reducing unnecessary lab testing in the ICU with artificial intelligence
Cismondi, F.; Celi, L.A.; Fialho, A.S.; Vieira, S.M.; Reti, S.R.; Sousa, J.M.C.; Finkelstein, S.N.
2017-01-01
Objectives To reduce unnecessary lab testing by predicting when a proposed future lab test is likely to contribute information gain and thereby influence clinical management in patients with gastrointestinal bleeding. Recent studies have demonstrated that frequent laboratory testing does not necessarily relate to better outcomes. Design Data preprocessing, feature selection, and classification were performed and an artificial intelligence tool, fuzzy modeling, was used to identify lab tests that do not contribute an information gain. There were 11 input variables in total. Ten of these were derived from bedside monitor trends heart rate, oxygen saturation, respiratory rate, temperature, blood pressure, and urine collections, as well as infusion products and transfusions. The final input variable was a previous value from one of the eight lab tests being predicted: calcium, PTT, hematocrit, fibrinogen, lactate, platelets, INR and hemoglobin. The outcome for each test was a binary framework defining whether a test result contributed information gain or not. Patients Predictive modeling was applied to recognize unnecessary lab tests in a real world ICU database extract comprising 746 patients with gastrointestinal bleeding. Main results Classification accuracy of necessary and unnecessary lab tests of greater than 80% was achieved for all eight lab tests. Sensitivity and specificity were satisfactory for all the outcomes. An average reduction of 50% of the lab tests was obtained. This is an improvement from previously reported similar studies with average performance 37% by [1–3]. Conclusions Reducing frequent lab testing and the potential clinical and financial implications are an important issue in intensive care. In this work we present an artificial intelligence method to predict the benefit of proposed future laboratory tests. Using ICU data from 746 patients with gastrointestinal bleeding, and eleven measurements, we demonstrate high accuracy in predicting the likely information to be gained from proposed future lab testing for eight common GI related lab tests. Future work will explore applications of this approach to a range of underlying medical conditions and laboratory tests. PMID:23273628
2010-04-13
NATHAN HORACE STRONG (AEROSPACE ENGINEER, ER31 PROPULSION TURBOMACHINERY DESIGN & DEVELOPMENT BRANCH) AND NATHAN COFFEE (EM10 MATERIALS TEST ENGINEER, JACOBS ESTS GROUP/JTI) ADJUST A UNIQUE MECHANICAL TEST SETUP THAT MEASURES STRAIN ON A SINGLE SAMPLE, USING TWO DIFFERENT TECHNIQUES AT THE SAME TIME. THE TEST FIXTURE HOLDS A SPECIMEN THAT REPRESENTS A LIQUID OXYGEN (LOX) BEARING FROM THE J2-X ENGINE. COFFEY, AT RIGHT, WORK IN A LAB IN BUILDING 4612 ON A BEARING TEST
NASA Technical Reports Server (NTRS)
Oneill-Rood, Nora; Glover, Richard D.
1990-01-01
NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.
The Effect of Triage on Patient Flow in an Outpatient Clinic.
1979-12-01
returns the records to the reception desk, and then checks his in- basket to call his next patient. If lab tests or X-rays are indicated and the patient is...Waiting times 7 Start and end of Provider service time provider service Total service time 8 Lab tests Percentage of lab tests ordered by screener 9 Lab... tests Percentage of lab tests ordered by provider Second provider start Provider service time and end of service Total service time 10 Referral to
2010-03-11
Students, Ajay Ramesh and Prithvi Aiyaswamy in 7th grade, Chaboya Middle School, San Jose, have entered the Intel Inernational Science Fair (May 2010) They are here at the Ames Research center to test the drag of race cars in the Fluid Mechanics Lab (FML)
2010-03-11
Students, Ajay Ramesh and Prithvi Aiyaswamy in 7th grade, Chaboya Middle School, San Jose, have entered the Intel Inernational Science Fair (May 2010) They are here at the Ames Research center to test the drag of race cars in the Fluid Mechanics Lab (FML)
2010-03-11
Students, Ajay Ramesh and Prithvi Aiyaswamy in 7th grade, Chaboya Middle School, San Jose, have entered the Intel Inernational Science Fair (May 2010) They are here at the Ames Research center to test the drag of race cars in the Fluid Mechanics Lab (FML)
2010-03-11
Students, Ajay Ramesh and Prithvi Aiyaswamy in 7th grade, Chaboya Middle School, San Jose, have entered the Intel Inernational Science Fair (May 2010) They are here at the Ames Research center to test the drag of race cars in the Fluid Mechanics Lab (FML)
2010-03-11
Students, Ajay Ramesh and Prithvi Aiyaswamy in 7th grade, Chaboya Middle School, San Jose, have entered the Intel Inernational Science Fair (May 2010) They are here at the Ames Research center to test the drag of race cars in the Fluid Mechanics Lab (FML)
2010-03-11
Students, Ajay Ramesh and Prithvi Aiyaswamy in 7th grade, Chaboya Middle School, San Jose, have entered the Intel Inernational Science Fair (May 2010) They are here at the Ames Research center to test the drag of race cars in the Fluid Mechanics Lab (FML)
Extreme Environments Test Capabilities at NASA GRC for Parker Hannifin Visit
NASA Technical Reports Server (NTRS)
Arnett, Lori
2016-01-01
The presentation includes general description on the following test facilities: Fuel Cell Testing Lab, Structural Dynamics Lab, Thermal Vacuum Test Facilities - including a description of the proposed Kinetic High Altitude Simulator concept, EMI Test Lab, and the Creek Road Cryogenic Complex - specifically the Small Multi-purpose Research Facility (SMiRF) and the Cryogenics Components Lab 7 (CCL-7).
DOT National Transportation Integrated Search
2004-01-01
The considerable increase of using geosynthetics in mechanically stabilized earth (MSE) walls has raised the need to evaluate their interface shear strength and pullout properties in various types of backfills. This report investigates the use of a m...
Glucose in Urine Test: MedlinePlus Lab Test Information
... Lab Tests Online [Internet]. American Association for Clinical Chemistry; c2001–2017. Diabetes [updated 2017 Jan 15; cited ... Lab Tests Online [Internet]. American Association for Clinical Chemistry; c2001–2017. Glucose Tests: Common Questions [updated 2017 ...
Systems special investigation group
NASA Technical Reports Server (NTRS)
1991-01-01
An interim report concerning the Long Duration Exposure Facility (LDEF) is presented by a Boeing Systems special investigation group (SIG). The SIG activities were divided into five engineering disciplines: electrical, mechanical, optics, thermal, and batteries/solar cells. The responsibilities of the SIG included the following areas: support de-integration at Kennedy Space Center (KSC); testing of hardware at Boeing; review of principal investigator (PI) test plans and test results; support of test activities at PI labs; and collation of all test results into the SIG database.
A microphysical model explains rate-and-state friction
NASA Astrophysics Data System (ADS)
Chen, Jianye; Spiers, Christopher J.
2015-04-01
The rate-and-state friction (RSF) laws were originally developed as a phenomenological description of the frictional behavior observed in lab experiments. In previous studies, the empirical RSF laws have been extensively and quite successfully applied to fault mechanisms. However, these laws can not readily be envisioned in terms of the underlying physics. There are several critical discrepancies between seismological constraints on RSF behavior associated with earthquakes and lab-derived RSF parameters, in particular regarding the static stress drop and characteristic slip distance associated with seismic events. Moreover, lab friction studies can address only limited fault topographies, displacements, experimental durations and P-T conditions, which means that scale issues, and especially processes like dilatation and fluid-rock interaction, cannot be fully taken into account. Without a physical basis accounting for such effects, extrapolation of lab-derived RSF data to nature involves significant, often unknown uncertainties. In order to more reliably apply experimental results to natural fault zones, and notably to extrapolate lab data beyond laboratory pressure, temperature and velocity conditions, an understanding of the microphysical mechanisms governing fault frictional behavior is required. Here, following some pioneering efforts (e.g. Niemeijer and Spiers, 2007; Den Hartog and Spiers, 2014), a mechanism-based microphysical model is developed for describing the frictional behavior of carbonate fault gouge, assuming that the frictional behavior seen in lab experiments is controlled by competing processes of intergranular slip versus contact creep by pressure solution. The model basically consists of two governing equations derived from energy/entropy balance considerations and the kinematic relations that apply to a granular fault gouge undergoing shear and dilation/compaction. These two equations can be written as ˙τ/K = Vimp- Lt[λ˙γsbps +(1- λ)˙γbpuslk]- Ltλ˙γsbps ------σn------- σn(μbar+ 2tanψ) - τ(1 - barμtanψ) (1) τ(1 - barμtanψ) - σ (μbar+ tanψ) φ˙sb = --------n-----˙γsbps(1- φsb) σn(barμ+ 2tan ψ)- τ(1- barμtan ψ) (2) They describe the evolution of shear stress (τ) and shear band porosity (φsb) in response to any boundary conditions imposed. By solving these two controlling equations, and using standard creep equations to describe gouge compaction by pressure solution, typical lab-frictional tests were simulated, namely 'velocity stepping' and 'slide-hold-slide' test sequences, using velocity histories and environmental conditions employed in the experiments summarized above. The modeling results capture all of the main features and trends seen in the experimental data, including both steady-state and transient aspects of the observed behavior, with reasonable quantitative agreement. The model is the first mechanism-based model that I am aware of that can reproduce RSF-like behavior without recourse to the RSF law. Since it is microphysically based, the approach adopted should help provide a much improved framework for extrapolating friction data to natural conditions.
Sodium Blood Test: MedlinePlus Lab Test Information
... Lab Tests Online [Internet]. American Association for Clinical Chemistry; c2001–2017. Cirrhosis; [updated 2017 Jan 8; cited ... Lab Tests Online [Internet]. American Association for Clinical Chemistry; c2001–2017. Electrolytes: Common Questions [updated 2015 Dec ...
NASA Astrophysics Data System (ADS)
Patkar, Rajul S.; Ashwin, Mamta; Rao, V. Ramgopal
2017-12-01
Monitoring of soil nutrients is very important in precision agriculture. In this paper, we have demonstrated a micro electro mechanical system based lab-on-a-chip system for detection of various soil macronutrients which are available in ionic form K+, NO3-, and H2PO4-. These sensors are highly sensitive piezoresistive silicon microcantilevers coated with a polymer matrix containing methyltridodecylammonium nitrate ionophore/ nitrate ionophore VI for nitrate sensing, 18-crown-6 ether for potassium sensing and Tributyltin chloride for phosphate detection. A complete lab-on-a-chip system integrating a highly sensitive current excited Wheatstone's bridge based portable electronic setup along with arrays of microcantilever devices mounted on a printed circuit board with a liquid flow cell for on the site experimentation for soil test has been demonstrated.
Yang, Xiaojian; Brisbin, Jennifer; Yu, Hai; Wang, Qi; Yin, Fugui; Zhang, Yonggang; Sabour, Parviz; Sharif, Shayan; Gong, Joshua
2014-01-01
Probiotics have been used to control Salmonella colonization/infection in chickens. Yet the mechanisms of probiotic effects are not fully understood. This study has characterized our previously-selected lactic acid-producing bacterial (LAB) isolates for controlling Salmonella infection in chickens, particularly the mechanism underlying the control. In vitro studies were conducted to characterize 14 LAB isolates for their tolerance to low pH (2.0) and high bile salt (0.3-1.5%) and susceptibility to antibiotics. Three chicken infection trials were subsequently carried out to evaluate four of the isolates for reducing the burden of Salmonella enterica serovar Typhimurium in the broiler cecum. Chicks were gavaged with LAB cultures (10(6-7) CFU/chick) or phosphate-buffered saline (PBS) at 1 day of age followed by Salmonella challenge (10(4) CFU/chick) next day. Samples of cecal digesta, spleen, and liver were examined for Salmonella counts on days 1, 3, or 4 post-challenge. Salmonella in the cecum from Trial 3 was also assessed for the expression of ten virulence genes located in its pathogenicity island-1 (SPI-1). These genes play a role in Salmonella intestinal invasion. Tested LAB isolates (individuals or mixed cultures) were unable to lower Salmonella burden in the chicken cecum, but able to attenuate Salmonella infection in the spleen and liver. The LAB treatments also reduced almost all SPI-1 virulence gene expression (9 out of 10) in the chicken cecum, particularly at the low dose. In vitro treatment with the extracellular culture fluid from a LAB culture also down-regulated most SPI-1 virulence gene expression. The possible correlation between attenuation of Salmonella infection in the chicken spleen and liver and reduction of Salmonella SPI-1 virulence gene expression in the chicken cecum by LAB isolates is a new observation. Suppression of Salmonella virulence gene expression in vivo can be one of the strategies for controlling Salmonella infection in chickens.
Developing Avionics Hardware and Software for Rocket Engine Testing
NASA Technical Reports Server (NTRS)
Aberg, Bryce Robert
2014-01-01
My summer was spent working as an intern at Kennedy Space Center in the Propulsion Avionics Branch of the NASA Engineering Directorate Avionics Division. The work that I was involved with was part of Rocket University's Project Neo, a small scale liquid rocket engine test bed. I began by learning about the layout of Neo in order to more fully understand what was required of me. I then developed software in LabView to gather and scale data from two flowmeters and integrated that code into the main control software. Next, I developed more LabView code to control an igniter circuit and integrated that into the main software, as well. Throughout the internship, I performed work that mechanics and technicians would do in order to maintain and assemble the engine.
Qualification Lab Testing on M1 Abrams Engine Oil Filters
2016-11-01
UNCLASSIFIED QUALIFICATION LAB TESTING ON M1 ABRAMS ENGINE OIL FILTERS FINAL REPORT TFLRF No. 483 by Kristi K. Rutta U.S...the originator. UNCLASSIFIED QUALIFICATION LAB TESTING ON M1 ABRAMS ENGINE OIL FILTERS FINAL REPORT TFLRF No. 483 by Kristi K...TITLE AND SUBTITLE Qualification Lab Testing on M1 Abrams Engine Oil Filter 5a. CONTRACT NUMBER W56HZV-15-C-0030 5b. GRANT NUMBER 5c. PROGRAM
AnimatLab: a 3D graphics environment for neuromechanical simulations.
Cofer, David; Cymbalyuk, Gennady; Reid, James; Zhu, Ying; Heitler, William J; Edwards, Donald H
2010-03-30
The nervous systems of animals evolved to exert dynamic control of behavior in response to the needs of the animal and changing signals from the environment. To understand the mechanisms of dynamic control requires a means of predicting how individual neural and body elements will interact to produce the performance of the entire system. AnimatLab is a software tool that provides an approach to this problem through computer simulation. AnimatLab enables a computational model of an animal's body to be constructed from simple building blocks, situated in a virtual 3D world subject to the laws of physics, and controlled by the activity of a multicellular, multicompartment neural circuit. Sensor receptors on the body surface and inside the body respond to external and internal signals and then excite central neurons, while motor neurons activate Hill muscle models that span the joints and generate movement. AnimatLab provides a common neuromechanical simulation environment in which to construct and test models of any skeletal animal, vertebrate or invertebrate. The use of AnimatLab is demonstrated in a neuromechanical simulation of human arm flexion and the myotactic and contact-withdrawal reflexes. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Bottom-up laboratory testing of the DKIST Visible Broadband Imager (VBI)
NASA Astrophysics Data System (ADS)
Ferayorni, Andrew; Beard, Andrew; Cole, Wes; Gregory, Scott; Wöeger, Friedrich
2016-08-01
The Daniel K. Inouye Solar Telescope (DKIST) is a 4-meter solar observatory under construction at Haleakala, Hawaii [1]. The Visible Broadband Imager (VBI) is a first light instrument that will record images at the highest possible spatial and temporal resolution of the DKIST at a number of scientifically important wavelengths [2]. The VBI is a pathfinder for DKIST instrumentation and a test bed for developing processes and procedures in the areas of unit, systems integration, and user acceptance testing. These test procedures have been developed and repeatedly executed during VBI construction in the lab as part of a "test early and test often" philosophy aimed at identifying and resolving issues early thus saving cost during integration test and commissioning on summit. The VBI team recently completed a bottom up end-to-end system test of the instrument in the lab that allowed the instrument's functionality, performance, and usability to be validated against documented system requirements. The bottom up testing approach includes four levels of testing, each introducing another layer in the control hierarchy that is tested before moving to the next level. First the instrument mechanisms are tested for positioning accuracy and repeatability using a laboratory position-sensing detector (PSD). Second the real-time motion controls are used to drive the mechanisms to verify speed and timing synchronization requirements are being met. Next the high-level software is introduced and the instrument is driven through a series of end-to-end tests that exercise the mechanisms, cameras, and simulated data processing. Finally, user acceptance testing is performed on operational and engineering use cases through the use of the instrument engineering graphical user interface (GUI). In this paper we present the VBI bottom up test plan, procedures, example test cases and tools used, as well as results from test execution in the laboratory. We will also discuss the benefits realized through completion of this testing, and share lessons learned from the bottoms up testing process.
Screening and characterization of novel bacteriocins from lactic acid bacteria.
Zendo, Takeshi
2013-01-01
Bacteriocins produced by lactic acid bacteria (LAB) are expected to be safe antimicrobial agents. While the best studied LAB bacteriocin, nisin A, is widely utilized as a food preservative, various novel ones are required to control undesirable bacteria more effectively. To discover novel bacteriocins at the early step of the screening process, we developed a rapid screening system that evaluates bacteriocins produced by newly isolated LAB based on their antibacterial spectra and molecular masses. By means of this system, various novel bacteriocins were identified, including a nisin variant, nisin Q, a two-peptide bacteriocin, lactococcin Q, a leaderless bacteriocin, lacticin Q, and a circular bacteriocin, lactocyclicin Q. Moreover, some LAB isolates were found to produce multiple bacteriocins. They were characterized as to their structures, mechanisms of action, and biosynthetic mechanisms. Novel LAB bacteriocins and their biosynthetic mechanisms are expected for applications such as food preservation and peptide engineering.
Study on property and stability mechanism of LAB-AEO-4 system
NASA Astrophysics Data System (ADS)
Song, Kaifei; Ge, Jijiang; Wang, Yang; Zhang, Guicai; Jiang, Ping
2017-04-01
The behaviors of binary blending systems of fatty alcohol polyoxyethylene ether (AEO-4) blended with the laurel amide betaine (LAB) was investigated at 80°C,the results indicated that the optimal ratio of the mixed system of LAB-AEO-4 was 5:2. The stability mechanism of LAB-AEO-4 system was analyzed from three aspects of dynamic surface tension,gas permeation rate and surface rheology.The results showed that the tension of mixed system was easier to achieve balance,the constant of gas permeation rate of the mixed system decreased by about 7% and the elastic modulus and dilational modulus increased by about 2 times compared with the single LAB system.
Development and Testing of Mechanism Technology for Space Exploration in Extreme Environments
NASA Technical Reports Server (NTRS)
Tyler, Tony R.; Levanas, Greg; Mojarradi, Mohammad M.; Abel, Phillip B.
2011-01-01
The NASA Jet Propulsion Lab (JPL), Glenn Research Center (GRC), Langley Research Center (LaRC), and Aeroflex, Inc. have partnered to develop and test actuator hardware that will survive the stringent environment of the moon, and which can also be leveraged for other challenging space exploration missions. Prototype actuators have been built and tested in a unique low temperature test bed with motor interface temperatures as low as 14 degrees Kelvin. Several years of work have resulted in specialized electro-mechanical hardware to survive extreme space exploration environments, a test program that verifies and finds limitations of the designs at extreme temperatures, and a growing knowledge base that can be leveraged by future space exploration missions.
2010-03-11
Students, Ajay Ramesh and Prithvi Aiyaswamy in 7th grade, Chaboya Middle School, San Jose, have entered the Intel Inernational Science Fair (May 2010) They are here at the Ames Research center to test the drag of race cars in the Fluid Mechanics Lab (FML) with the guidance of Kurt Long of the Experimental Aero-Physics Branch.
Improved Storage Stability of Meal, Ready-To-Eat Cheese Spread Under Heat-Stressing Conditions
2009-11-01
7 3.2 Hunter L*a*b Colorimetry ...10 4.2 Hunter L*a*b Colorimetry ...testing, the study consisted of L*a*b* colorimetry , photography, emulsion stability testing, and First Strike Ration™ field testing at Fort Bragg, NC
NASA Astrophysics Data System (ADS)
Corsi, Gianluca
2011-12-01
Web-based technology has revolutionized the way education is delivered. Although the advantages of online learning appeal to large numbers of students, some concerns arise. One major concern in online science education is the value that participation in labs has on student performance. The purpose of this study was to assess the relationships between lab completion and student academic success as measured by test grades, scientific self-confidence, scientific skills, and concept mastery. A random sample of 114 volunteer undergraduate students, from an online Environmental Science program at the American Public University System, was tested. The study followed a quantitative, non-experimental research design. Paired sample t-tests were used for statistical comparison between pre-lab and post-lab test grades, two scientific skills quizzes, and two scientific self-confidence surveys administered at the beginning and at the end of the course. The results of the paired sample t-tests revealed statistically significant improvements on all post-lab test scores: Air Pollution lab, t(112) = 6.759, p < .001; Home Chemicals lab t(114) = 8.585, p < .001; Water Use lab, t(116) = 6.657, p < .001; Trees and Carbon lab, t(113) = 9.921, p < .001; Stratospheric Ozone lab, t(112) =12.974, p < .001; Renewable Energy lab, t(115) = 7.369, p < .001. The end of the course Scientific Skills quiz revealed statistically significant improvements, t(112) = 8.221, p < .001. The results of the two surveys showed a statistically significant improvement on student Scientific Self-Confidence because of lab completion, t(114) = 3.015, p < .05. Because age and gender were available, regression models were developed. The results indicated weak multiple correlation coefficients and were not statistically significant at alpha = .05. Evidence suggests that labs play a positive role in a student's academic success. It is recommended that lab experiences be included in all online Environmental Science programs, with emphasis on open-ended inquiries, and adoption of online tools to enhance hands-on experiences, such as virtual reality platforms and digital animations. Future research is encouraged to investigate possible correlations between socio-demographic attributes and academic success of students enrolled in online science programs in reference to lab completion.
The Portable Usability Testing Lab: A Flexible Research Tool.
ERIC Educational Resources Information Center
Hale, Michael E.; And Others
A group of faculty at the University of Georgia obtained funding for a research and development facility called the Learning and Performance Support Laboratory (LPSL). One of the LPSL's primary needs was obtaining a portable usability lab for software testing, so the facility obtained the "Luggage Lab 2000." The lab is transportable to…
Lactic acid bacterial extract as a biogenic mineral growth modifier
NASA Astrophysics Data System (ADS)
Borah, Ballav M.; Singh, Atul K.; Ramesh, Aiyagari; Das, Gopal
2009-04-01
The formation of minerals and mechanisms by which bacteria could control their formation in natural habitats is now of current interest for material scientists to have an insight of the mechanism of in vivo mineralization, as well as to seek industrial and technological applications. Crystalline uniform structures of calcium and barium minerals formed micron-sized building blocks when synthesized in the presence of an organic matrix consisting of secreted protein extracts from three different lactic acid bacteria (LAB) viz.: Lactobacillus plantarum MTCC 1325, Lactobacillus acidophilus NRRL B4495 and Pediococcus acidilactici CFR K7. LABs are not known to form organic matrix in biological materialization processes. The influence of these bacterial extracts on the crystallization behavior was investigated in details to test the basic coordination behavior of the acidic protein. In this report, varied architecture of the mineral crystals obtained in presence of high molecular weight protein extracts of three different LAB strains has been discussed. The role of native form of high molecular weight bacterial protein extracts in the generation of nucleation centers for crystal growth was clearly established. A model for the formation of organic matrix-cation complex and the subsequent events leading to crystal growth is proposed.
NASA Astrophysics Data System (ADS)
Pohlman, Nicholas A.; Hynes, Eric; Kutz, April
2015-11-01
Lectures in introductory fluid mechanics at NIU are a combination of students with standard enrollment and students seeking honors credit for an enriching experience. Most honors students dread the additional homework problems or an extra paper assigned by the instructor. During the past three years, honors students of my class have instead collaborated to design wet-lab experiments for their peers to predict variable volume flow rates of open reservoirs driven by gravity. Rather than learn extra, the honors students learn the Bernoulli head-loss equation earlier to design appropriate systems for an experimental wet lab. Prior designs incorporated minor loss features such as sudden contraction or multiple unions and valves. The honors students from Spring 2015 expanded the repertoire of available options by developing large scale set-ups with multiple pipe networks that could be combined together to test the flexibility of the student team's computational programs. The engagement of bridging the theory with practice was appreciated by all of the students such that multiple teams were able to predict performance within 4% accuracy. The challenges, schedules, and cost estimates of incorporating the experimental lab into an introductory fluid mechanics course will be reported.
Evaluating learning and teaching using the Force Concept Inventory
NASA Astrophysics Data System (ADS)
Zitzewitz, Paul
1997-04-01
Teaching methods used in the calculus-based mechanics course for engineers and scientists (P150) at the University of Michigan-Dearborn were markedly changed in September, 1996. Lectures emphasize active learning with Mazur's ConcepTests, Sokoloff's Interactive Demonstrations, and Van Heuvelen's ALPS Kit worksheets. Students solve context-rich problems using Van Heuvelen's multiple representation format in cooperative groups in discussion sections. Labs were changed to use MBL emphasizing concepts and Experiment Problems to learn lab-based problem solving. Pre- and post-testing of 400 students with the Force Concept Inventory has demonstrated considerable success. The average increase in score has been 35-45methods as defined by Hake. The methods and results will be discussed. Detailed analyses of the FCI results will look at success in teaching specific concepts and the effect of student preparation in mathematics and high school physics.
Finding Better and More Personalized Ways to Diagnose Cancer at NIH | NIH MedlinePlus the Magazine
... may have you do a lab test. Lab tests High or low levels of certain substances in your body can be a sign of cancer. Blood, urine, and other lab tests measure these substances to help doctors make a ...
Effects of die quench forming on sheet thinning and 3-point bend testing of AA7075-T6
NASA Astrophysics Data System (ADS)
Kim, Samuel; Omer, Kaab; Rahmaan, Taamjeed; Butcher, Clifford; Worswick, Michael
2017-10-01
Lab-scaled AA7075 aluminum side impact beams were manufactured using the die quenching technique in which the sheet was solutionized and then quenched in-die during forming to a super saturated solid state. Sheet thinning measurements were taken at various locations throughout the length of the part and the effect of lubricant on surface scoring and material pick-up on the die was evaluated. The as-formed beams were subjected to a T6 aging treatment and then tested in three-point bending. Simulations were performed of the forming and mechanical testing experiments using the LS-DYNA finite element code. The thinning and mechanical response was predicted well.
Enhanced Low Dose Rate Effects in Bipolar Circuits: A New Hardness Assurance Problem for NASA
NASA Technical Reports Server (NTRS)
Johnston, A.; Barnes, C.
1995-01-01
Many bipolar integrated circuits are much more susceptible to ionizing radiation at low dose rates than they are at high dose rates typically used for radiation parts testing. Since the low dose rate is equivalent to that seen in space, the standard lab test no longer can be considered conservative and has caused the Air Force to issue an alert. Although a reliable radiation hardness assurance test has not yet been designed, possible mechanisms for low dose rate enhancement and hardness assurance tests are discussed.
Ziman, Melanie E; Bui, Hien T; Smith, Craig S; Tsukiji, Lori A; Asmatey, Veda M; Chu, Steven B; Miano, John S
2012-04-01
This single-center retrospective pilot program's objective was to utilize outpatient pharmacists to improve laboratory test adherence in chronic heart failure (CHF) patients overdue for thyroid function testing, thereby demonstrating the value of the outpatient pharmacist and justifying possible clinical role expansion. Thyroid disorders may contribute to CHF development, progression, and exacerbation. Testing is the standard of care in CHF patients per American Heart Association's 2009 Guidelines. Delinquency was defined as labs not conducted within 1 year in patients with euthyroid history, within 6 months in patients with thyroid dysfunction, abnormal labs at any time without follow-up, or lab absence after thyroid medication initiation, adjustment, or discontinuation. Targeted 80 nonpregnant adult CHF patients with delinquent thyroid function tests were counseled to get thyroid labs at point of sale, via telephone, e-mail, or letter. In collaboration with physicians, pharmacists ordered thyroid-stimulating hormone (TSH) and free T4 (FT4) labs. For patients with abnormal laboratory results, pharmacists coordinated drug therapy and follow-up labs. Data were collected from November 1, 2009 to March 30, 2010. Seventy-two patients (90%) previously delinquent for thyroid function testing received relevant thyroid labs. Ten patients (12.5%) with abnormal thyroid function tests not on prior drug therapy received treatment.
2011-11-08
CAPE CANAVERAL, Fla. – In the Granular Mechanics and Regolith Operations (GMRO) Lab at NASA's Kennedy Space Center in Florida, pieces of the Surveyor 3 spacecraft returned from the lunar surface on the Apollo 12 mission are available for examination by the lab's staff. The GMRO Lab is one of several labs located in NASA's Space Life Sciences Laboratory (SLSL) facility. The lab is staffed by three physicists, six mechanical or aerospace engineers and several technicians who are studying how the rocket exhaust of landing vehicles affects lunar and Martian science missions, including the sandblasting of instruments with soil and dust ejecta and the disturbance or contamination of soil beneath the lander. For more information on the GMRO Lab, see p. 7 of the Spaceport News dated Nov. 11, 2011, at http://www.nasa.gov/centers/kennedy/pdf/603285main_nov11-2011.pdf. Photo credit: NASA/Jim Grossmann
2011-11-08
CAPE CANAVERAL, Fla. – In the Granular Mechanics and Regolith Operations (GMRO) Lab at NASA's Kennedy Space Center in Florida, a piece of the Surveyor 3 spacecraft returned from the lunar surface on the Apollo 12 mission is available for examination by the lab's staff. The GMRO Lab is one of several labs located in NASA's Space Life Sciences Laboratory (SLSL) facility. The lab is staffed by three physicists, six mechanical or aerospace engineers and several technicians who are studying how the rocket exhaust of landing vehicles affects lunar and Martian science missions, including the sandblasting of instruments with soil and dust ejecta and the disturbance or contamination of soil beneath the lander. For more information on the GMRO Lab, see p. 7 of the Spaceport News dated Nov. 11, 2011, at http://www.nasa.gov/centers/kennedy/pdf/603285main_nov11-2011.pdf. Photo credit: NASA/Jim Grossmann
Jones, Brandon W; Venditti, Richard; Park, Sunkyu; Jameel, Hasan
2014-09-01
Mechanical refining has been shown to improve biomass enzymatic digestibility. In this study industrial high-yield sodium carbonate hardwood pulp was subjected to lab, pilot and industrial refining to determine if the mechanical refining improves the enzymatic hydrolysis sugar conversion efficiency differently at different refining scales. Lab, pilot and industrial refining increased the biomass digestibility for lignocellulosic biomass relative to the unrefined material. The sugar conversion was increased from 36% to 65% at 5 FPU/g of biomass with industrial refining at 67.0 kWh/t, which was more energy efficient than lab and pilot scale refining. There is a maximum in the sugar conversion with respect to the amount of refining energy. Water retention value is a good predictor of improvements in sugar conversion for a given fiber source and composition. Improvements in biomass digestibility with refining due to lab, pilot plant and industrial refining were similar with respect to water retention value. Published by Elsevier Ltd.
The comparison of manual and LabVIEW-based fuzzy control on mechanical ventilation.
Guler, Hasan; Ata, Fikret
2014-09-01
The aim of this article is to develop a knowledge-based therapy for management of rats with respiratory distress. A mechanical ventilator was designed to achieve this aim. The designed ventilator is called an intelligent mechanical ventilator since fuzzy logic was used to control the pneumatic equipment according to the rat's status. LabVIEW software was used to control all equipments in the ventilator prototype and to monitor respiratory variables in the experiment. The designed ventilator can be controlled both manually and by fuzzy logic. Eight female Wistar-Albino rats were used to test the designed ventilator and to show the effectiveness of fuzzy control over manual control on pressure control ventilation mode. The anesthetized rats were first ventilated for 20 min manually. After that time, they were ventilated for 20 min by fuzzy logic. Student's t-test for p < 0.05 was applied to the measured minimum, maximum and mean peak inspiration pressures to analyze the obtained results. The results show that there is no statistical difference in the rat's lung parameters before and after the experiments. It can be said that the designed ventilator and developed knowledge-based therapy support artificial respiration of living things successfully. © IMechE 2014.
The variability of the indirect tensile stripping test.
DOT National Transportation Integrated Search
1990-01-01
The purpose of this investigation was to determine the variability of the Virginia Department of Transportation's (VDOT) indirect tensile stripping test. Five contractor labs and eight VDOT labs participated in the study. Each lab performed three rep...
NASA Astrophysics Data System (ADS)
Budhwani, Karim Ismail
The tremendous quality of life impact notwithstanding, cardiovascular diseases and Cancer add up to over US$ 700bn each year in financial costs alone. Aging and population growth are expected to further expand the problem space while drug research and development remain expensive. However, preclinical costs can be substantially mitigated by substituting animal models with in vitro devices that accurately model human cardiovascular transport. Here we present a novel physiologically relevant lab-on-a-brane that simulates in vivo pressure, flow, strain, and shear waveforms associated with normal and pathological conditions in large and small blood vessels for studying molecular transport across the endothelial monolayer. The device builds upon previously demonstrated integrated microfluidic loop design by: (a) introducing nanoscale pores in the substrate membrane to enable transmembrane molecular transport, (b) transforming the substrate membrane into a nanofibrous matrix for 3D smooth muscle cell (SMC) tissue culture, (c) integrating electrospinning fabrication methods, (d) engineering an invertible sandwich cell culture device architecture, and (e) devising a healthy co-culture mechanism for human arterial endothelial cell (HAEC) monolayer and multiple layers of human smooth muscle cells (HSMC) to accurately mimic arterial anatomy. Structural and mechanical characterization was conducted using confocal microscopy, SEM, stress/strain analysis, and infrared spectroscopy. Transport was characterized using FITC-Dextran hydraulic permeability protocol. Structure and transport characterization successfully demonstrate device viability as a physiologically relevant arterial mimic for testing transendothelial transport. Thus, our lab-on-a-brane provides a highly effective and efficient, yet considerably inexpensive, physiologically relevant alternative for pharmacokinetic evaluation; possibly reducing animals used in pre-clinical testing, clinical trials cost from false starts, and time-to-market. Furthermore, this platform can be easily configured for testing targeted therapeutic delivery and in multiple simultaneous arrays for personalized and precision medicine applications.
Baseball Physics: A New Mechanics Lab
NASA Astrophysics Data System (ADS)
Wagoner, Kasey; Flanagan, Daniel
2018-05-01
The game of baseball provides an interesting laboratory for experimenting with mechanical phenomena (there are many good examples in The Physics Teacher, available on Professor Alan Nathan's website, and discussed in Physics of Baseball & Softball). We have developed a lab, for an introductory-level physics course, that investigates many of these phenomena. The lab uses inexpensive, readily available equipment such as wooden baseball bats, baseballs, and actual Major League Baseball data. By the end of the lab, students have revisited many concepts they learned earlier in the semester and come away with an understanding of how to put seemingly disparate ideas together to analyze a fun sport.
Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-Ichiro
2010-06-01
A new OECD test guideline 431 (TG431) for in vitro skin corrosion tests using human reconstructed skin models was adopted by OECD in 2004. TG431 defines the criteria for the general function and performance of applicable skin models. In order to confirm that the new reconstructed human epidermal model, LabCyte EPI-MODEL is applicable for the skin corrosion test according to TG431, the predictability and repeatability of the model for the skin corrosion test was evaluated. The test was performed according to the test protocol described in TG431. Based on the knowledge that LabCyte EPI-MODEL is an epidermal model as well as EpiDerm, we decided to adopt the the Epiderm prediction model of skin corrosion for the LabCyte EPI-MODEL, using twenty test chemicals (10 corrosive chemicals and 10 non-corrosive chemicals) in the 1(st) stage. The prediction model results showed that the distinction of non-corrosion to corrosion corresponded perfectly. Therefore, it was judged that the prediction model of EpiDerm could be applied to the LabCyte EPI-MODEL. In the 2(nd) stage, the repeatability of this test protocol with the LabCyte EPI-MODEL was examined using twelve chemicals (6 corrosive chemicals and 6 non-corrosive chemicals) that are described in TG431, and these results recognized a high repeatability and accurate predictability. It was concluded that LabCyte EPI-MODEL is applicable for the skin corrosive test protocol according to TG431.
Yang, Xiaojian; Brisbin, Jennifer; Yu, Hai; Wang, Qi; Yin, Fugui; Zhang, Yonggang; Sabour, Parviz; Sharif, Shayan; Gong, Joshua
2014-01-01
Background Probiotics have been used to control Salmonella colonization/infection in chickens. Yet the mechanisms of probiotic effects are not fully understood. This study has characterized our previously-selected lactic acid-producing bacterial (LAB) isolates for controlling Salmonella infection in chickens, particularly the mechanism underlying the control. Methodology/Principal Findings In vitro studies were conducted to characterize 14 LAB isolates for their tolerance to low pH (2.0) and high bile salt (0.3–1.5%) and susceptibility to antibiotics. Three chicken infection trials were subsequently carried out to evaluate four of the isolates for reducing the burden of Salmonella enterica serovar Typhimurium in the broiler cecum. Chicks were gavaged with LAB cultures (106–7 CFU/chick) or phosphate-buffered saline (PBS) at 1 day of age followed by Salmonella challenge (104 CFU/chick) next day. Samples of cecal digesta, spleen, and liver were examined for Salmonella counts on days 1, 3, or 4 post-challenge. Salmonella in the cecum from Trial 3 was also assessed for the expression of ten virulence genes located in its pathogenicity island-1 (SPI-1). These genes play a role in Salmonella intestinal invasion. Tested LAB isolates (individuals or mixed cultures) were unable to lower Salmonella burden in the chicken cecum, but able to attenuate Salmonella infection in the spleen and liver. The LAB treatments also reduced almost all SPI-1 virulence gene expression (9 out of 10) in the chicken cecum, particularly at the low dose. In vitro treatment with the extracellular culture fluid from a LAB culture also down-regulated most SPI-1 virulence gene expression. Conclusions/Significance The possible correlation between attenuation of Salmonella infection in the chicken spleen and liver and reduction of Salmonella SPI-1 virulence gene expression in the chicken cecum by LAB isolates is a new observation. Suppression of Salmonella virulence gene expression in vivo can be one of the strategies for controlling Salmonella infection in chickens. PMID:24728092
Elman, Noel M; Ben-Yoav, Hadar; Sternheim, Marek; Rosen, Rachel; Krylov, Slava; Shacham-Diamand, Yosi
2008-06-15
A lab-on-chip consisting of a unique integration of whole-cell sensors, a MOEMS (Micro-Opto-Electro-Mechanical-System) modulator, and solid-state photo-detectors was implemented for the first time. Whole-cell sensors were genetically engineered to express a bioluminescent reporter (lux) as a function of the lac promoter. The MOEMS modulator was designed to overcome the inherent low frequency noise of solid-state photo-detectors by means of a previously reported modulation technique, named IHOS (Integrated Heterodyne Optical System). The bio-reporter signals were modulated prior to photo-detection, increasing the SNR of solid-state photo-detectors at least by three orders of magnitude. Experiments were performed using isopropyl-beta-d-thiogalactopyranoside (IPTG) as a preliminary step towards testing environmental toxicity. The inducer was used to trigger the expression response of the whole-cell sensors testing the sensitivity of the lab-on-chip. Low intensity bio-reporter optical signals were measured after the whole-cell sensors were exposed to IPTG concentrations of 0.1, 0.05, and 0.02mM. The experimental results reveal the potential of this technology for future implementation as an inexpensive massive method for rapid environmental toxicity detection.
Evaluation of Petrifilm Lactic Acid Bacteria Plates for Counting Lactic Acid Bacteria in Food.
Kanagawa, Satomi; Ohshima, Chihiro; Takahashi, Hajime; Burenqiqige; Kikuchi, Misato; Sato, Fumina; Nakamura, Ayaka; Mohamed, Shimaa M; Kuda, Takashi; Kimura, Bon
2018-06-01
Although lactic acid bacteria (LAB) are used widely as starter cultures in the production of fermented foods, they are also responsible for food decay and deterioration. The undesirable growth of LAB in food causes spoilage, discoloration, and slime formation. Because of these adverse effects, food companies test for the presence of LAB in production areas and processed foods and consistently monitor the behavior of these bacteria. The 3M Petrifilm LAB Count Plates have recently been launched as a time-saving and simple-to-use plate designed for detecting and quantifying LAB. This study compares the abilities of Petrifilm LAB Count Plates and the de Man Rogosa Sharpe (MRS) agar medium to determine the LAB count in a variety of foods and swab samples collected from a food production area. Bacterial strains isolated from Petrifilm LAB Count Plates were identified by 16S rDNA sequence analysis to confirm the specificity of these plates for LAB. The results showed no significant difference in bacterial counts measured by using Petrifilm LAB Count Plates and MRS medium. Furthermore, all colonies growing on Petrifilm LAB Count Plates were confirmed to be LAB, while yeast colonies also formed in MRS medium. Petrifilm LAB Count Plates eliminated the plate preparation and plate inoculation steps, and the cultures could be started as soon as a diluted food sample was available. Food companies are required to establish quality controls and perform tests to check the quality of food products; the use of Petrifilm LAB Count Plates can simplify this testing process for food companies.
Baseball Physics: A New Mechanics Lab
ERIC Educational Resources Information Center
Wagoner, Kasey; Flanagan, Daniel
2018-01-01
The game of baseball provides an interesting laboratory for experimenting with mechanical phenomena (there are many good examples in "The Physics Teacher," available on Professor Alan Nathan's website, and discussed in "Physics of Baseball & Softball"). We have developed a lab, for an introductory-level physics course, that…
4. VIEW SOUTHWEST COMPONENTS TEST LAB TEST BAY DETAIL SHOWING ...
4. VIEW SOUTHWEST COMPONENTS TEST LAB TEST BAY DETAIL SHOWING EMERGENCY SHOWER, AND EYEWASH, AND OBSERVATION WINDOW. STORAGE TANKS ON ROOF. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL
Living Lab as an Agile Approach in Developing User-Friendly Welfare Technology.
Holappa, Niina; Sirkka, Andrew
2017-01-01
This paper discusses living lab as a method of developing user-friendly welfare technology, and presents a qualitative evaluation research of how living lab tested technologies impacted on the life of healthcare customers and professionals over test periods.
Generalized Nanosatellite Avionics Testbed Lab
NASA Technical Reports Server (NTRS)
Frost, Chad R.; Sorgenfrei, Matthew C.; Nehrenz, Matt
2015-01-01
The Generalized Nanosatellite Avionics Testbed (G-NAT) lab at NASA Ames Research Center provides a flexible, easily accessible platform for developing hardware and software for advanced small spacecraft. A collaboration between the Mission Design Division and the Intelligent Systems Division, the objective of the lab is to provide testing data and general test protocols for advanced sensors, actuators, and processors for CubeSat-class spacecraft. By developing test schemes for advanced components outside of the standard mission lifecycle, the lab is able to help reduce the risk carried by advanced nanosatellite or CubeSat missions. Such missions are often allocated very little time for testing, and too often the test facilities must be custom-built for the needs of the mission at hand. The G-NAT lab helps to eliminate these problems by providing an existing suite of testbeds that combines easily accessible, commercial-offthe- shelf (COTS) processors with a collection of existing sensors and actuators.
Status of chemistry lab safety in Nepal.
Kandel, Krishna Prasad; Neupane, Bhanu Bhakta; Giri, Basant
2017-01-01
Chemistry labs can become a dangerous environment for students as the lab exercises involve hazardous chemicals, glassware, and equipment. Approximately one hundred thousand students take chemistry laboratory classes annually in Nepal. We conducted a survey on chemical lab safety issues across Nepal. In this paper, we assess the safety policy and equipment, protocols and procedures followed, and waste disposal in chemistry teaching labs. Significant population of the respondents believed that there is no monitoring of the lab safety in their lab (p<0.001). Even though many labs do not allow food and beverages inside lab and have first aid kits, they lack some basic safety equipment. There is no institutional mechanism to dispose lab waste and chemical waste is disposed haphazardly. Majority of the respondents believed that the safety training should be a part of educational training (p = 0.001) and they would benefit from short course and/or workshop on lab safety (p<0.001).
Status of chemistry lab safety in Nepal
Kandel, Krishna Prasad; Neupane, Bhanu Bhakta
2017-01-01
Chemistry labs can become a dangerous environment for students as the lab exercises involve hazardous chemicals, glassware, and equipment. Approximately one hundred thousand students take chemistry laboratory classes annually in Nepal. We conducted a survey on chemical lab safety issues across Nepal. In this paper, we assess the safety policy and equipment, protocols and procedures followed, and waste disposal in chemistry teaching labs. Significant population of the respondents believed that there is no monitoring of the lab safety in their lab (p<0.001). Even though many labs do not allow food and beverages inside lab and have first aid kits, they lack some basic safety equipment. There is no institutional mechanism to dispose lab waste and chemical waste is disposed haphazardly. Majority of the respondents believed that the safety training should be a part of educational training (p = 0.001) and they would benefit from short course and/or workshop on lab safety (p<0.001). PMID:28644869
Biological patterns: Novel indicators for pharmacological assays
NASA Technical Reports Server (NTRS)
Johnson, Jacqueline U.
1991-01-01
Variable gravity testing using the KC-135 demonstrated clearly that biological pattern formation was definitely shown to result from gravity alone, and not from oxygen gradients in solution. Motile pattern formation of spermatozoa are driven by alternate mechanisms, and apparently not affected by short-term changes in gravity. The chemical effects found appear to be secondary to the primary effect of gravity. Cryopreservation may be the remedy to the problem of 'spare' or 'standing order' biological samples for testing of space lab investigations, but further studies are necessary.
2010-02-01
environment *Courtesy : George Hawthorn of Hawaii Corrosion Lab Procedures Outdoor Exposure Kilauea Volcano * Campbell Industrial Park* – Volcanic and marine...Raghu Srinivasan and L.H. Hihara Hawaii Corrosion Laboratory University of Hawaii at Manoa Department of Mechanical Engineering Report Documentation Page...PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) University of Hawaii at Manoa,Department of
Hybrid Integrated Silicon Microfluidic Platform for Fluorescence Based Biodetection.
Chandrasekaran, Arvind; Acharya, Ashwin; You, Jian Liang; Soo, Kim Young; Packirisamy, Muthukumaran; Stiharu, Ion; Darveau, André
2007-09-11
The desideratum to develop a fully integrated Lab-on-a-chip device capable ofrapid specimen detection for high throughput in-situ biomedical diagnoses and Point-of-Care testing applications has called for the integration of some of the novel technologiessuch as the microfluidics, microphotonics, immunoproteomics and Micro ElectroMechanical Systems (MEMS). In the present work, a silicon based microfluidic device hasbeen developed for carrying out fluorescence based immunoassay. By hybrid attachment ofthe microfluidic device with a Spectrometer-on-chip, the feasibility of synthesizing anintegrated Lab-on-a-chip type device for fluorescence based biosensing has beendemonstrated. Biodetection using the microfluidic device has been carried out usingantigen sheep IgG and Alexafluor-647 tagged antibody particles and the experimentalresults prove that silicon is a compatible material for the present application given thevarious advantages it offers such as cost-effectiveness, ease of bulk microfabrication,superior surface affinity to biomolecules, ease of disposability of the device etc., and is thussuitable for fabricating Lab-on-a-chip type devices.
Comparison between simulations and lab results on the ASSIST test-bench
NASA Astrophysics Data System (ADS)
Le Louarn, Miska; Madec, Pierre-Yves; Kolb, Johann; Paufique, Jerome; Oberti, Sylvain; La Penna, Paolo; Arsenault, Robin
2016-07-01
We present the latest comparison results between laboratory tests carried out on the ASSIST test bench and Octopus end-to end simulations. We simulated, as closely to the lab conditions as possible, the different AOF modes (Maintenance and commissioning mode (SCAO), GRAAL (GLAO in the near IR), Galacsi Wide Field mode (GLAO in the visible) and Galacsi narrow field mode (LTAO in the visible)). We then compared the simulation results to the ones obtained on the lab bench. Several aspects were investigated, like number of corrected modes, turbulence wind speeds, LGS photon flux etc. The agreement between simulations and lab is remarkably good for all investigated parameters, giving great confidence in both simulation tool and performance of the AO system in the lab.
2011-11-08
CAPE CANAVERAL, Fla. – In the Granular Mechanics and Regolith Operations (GMRO) Lab at NASA's Kennedy Space Center in Florida, Dr. Philip Metzger examines under a microscope a piece of the Surveyor 3 spacecraft returned from the lunar surface on the Apollo 12 mission. The GMRO Lab is one of several labs located in NASA's Space Life Sciences Laboratory (SLSL) facility. The lab is staffed by three physicists, six mechanical or aerospace engineers and several technicians who are studying how the rocket exhaust of landing vehicles affects lunar and Martian science missions, including the sandblasting of instruments with soil and dust ejecta and the disturbance or contamination of soil beneath the lander. For more information on the GMRO Lab, see p. 7 of the Spaceport News dated Nov. 11, 2011, at http://www.nasa.gov/centers/kennedy/pdf/603285main_nov11-2011.pdf. Photo credit: NASA/Jim Grossmann
Walz, Stacy E; Smith, Maureen; Cox, Elizabeth; Sattin, Justin; Kind, Amy J H
2011-04-01
Previous studies have noted a high (41%) prevalence and poor discharge summary communication of pending laboratory (lab) tests at the time of hospital discharge for general medical patients. However, the prevalence and communication of pending labs within a high-risk population, specifically those patients discharged to sub-acute care (i.e., skilled nursing, rehabilitation, long-term care), remains unknown. To determine the prevalence and nature of lab tests pending at hospital discharge and their inclusion within hospital discharge summaries, for common sub-acute care populations. Retrospective cohort study. Stroke, hip fracture, and cancer patients discharged from a single large academic medical center to sub-acute care, 2003-2005 (N = 564) Pending lab tests were abstracted from the laboratory information system (LIS) and from each patient's discharge summary, then grouped into 14 categories and compared. Microbiology tests were sub-divided by culture type and number of days pending prior to discharge. Of sub-acute care patients, 32% (181/564) were discharged with pending lab tests per the LIS; however, only 11% (20/181) of discharge summaries documented these. Patients most often left the hospital with pending microbiology tests (83% [150/181]), particularly blood and urine cultures, and reference lab tests (17% [30/181]). However, 82% (61/74) of patients' pending urine cultures did not have 24-hour preliminary results, and 19% (13/70) of patients' pending blood cultures did not have 48-hour preliminary results available at the time of hospital discharge. Approximately one-third of the sub-acute care patients in this study had labs pending at discharge, but few were documented within hospital discharge summaries. Even after considering the availability of preliminary microbiology results, these omissions remain common. Future studies should focus on improving the communication of pending lab tests at discharge and evaluating the impact that this improved communication has on patient outcomes.
ERIC Educational Resources Information Center
Stoeckel, Marta R.
2018-01-01
Along-standing energy lab involves dropping bouncy balls and measuring their rebound heights on successive bounces. The lab demonstrates a situation in which the mechanical energy of a system is not conserved. Although students enjoyed the lab, the author wanted to deepen their thinking about energy, including the connections to motion, with a new…
Evolvable Smartphone-Based Platforms for Point-of-Care In-Vitro Diagnostics Applications.
Patou, François; AlZahra'a Alatraktchi, Fatima; Kjægaard, Claus; Dimaki, Maria; Madsen, Jan; Svendsen, Winnie E
2016-09-03
The association of smart mobile devices and lab-on-chip technologies offers unprecedented opportunities for the emergence of direct-to-consumer in vitro medical diagnostics applications. Despite their clear transformative potential, obstacles remain to the large-scale disruption and long-lasting success of these systems in the consumer market. For instance, the increasing level of complexity of instrumented lab-on-chip devices, coupled to the sporadic nature of point-of-care testing, threatens the viability of a business model mainly relying on disposable/consumable lab-on-chips. We argued recently that system evolvability, defined as the design characteristic that facilitates more manageable transitions between system generations via the modification of an inherited design, can help remedy these limitations. In this paper, we discuss how platform-based design can constitute a formal entry point to the design and implementation of evolvable smart device/lab-on-chip systems. We present both a hardware/software design framework and the implementation details of a platform prototype enabling at this stage the interfacing of several lab-on-chip variants relying on current- or impedance-based biosensors. Our findings suggest that several change-enabling mechanisms implemented in the higher abstraction software layers of the system can promote evolvability, together with the design of change-absorbing hardware/software interfaces. Our platform architecture is based on a mobile software application programming interface coupled to a modular hardware accessory. It allows the specification of lab-on-chip operation and post-analytic functions at the mobile software layer. We demonstrate its potential by operating a simple lab-on-chip to carry out the detection of dopamine using various electroanalytical methods.
Evolvable Smartphone-Based Platforms for Point-of-Care In-Vitro Diagnostics Applications
Patou, François; AlZahra’a Alatraktchi, Fatima; Kjægaard, Claus; Dimaki, Maria; Madsen, Jan; Svendsen, Winnie E.
2016-01-01
The association of smart mobile devices and lab-on-chip technologies offers unprecedented opportunities for the emergence of direct-to-consumer in vitro medical diagnostics applications. Despite their clear transformative potential, obstacles remain to the large-scale disruption and long-lasting success of these systems in the consumer market. For instance, the increasing level of complexity of instrumented lab-on-chip devices, coupled to the sporadic nature of point-of-care testing, threatens the viability of a business model mainly relying on disposable/consumable lab-on-chips. We argued recently that system evolvability, defined as the design characteristic that facilitates more manageable transitions between system generations via the modification of an inherited design, can help remedy these limitations. In this paper, we discuss how platform-based design can constitute a formal entry point to the design and implementation of evolvable smart device/lab-on-chip systems. We present both a hardware/software design framework and the implementation details of a platform prototype enabling at this stage the interfacing of several lab-on-chip variants relying on current- or impedance-based biosensors. Our findings suggest that several change-enabling mechanisms implemented in the higher abstraction software layers of the system can promote evolvability, together with the design of change-absorbing hardware/software interfaces. Our platform architecture is based on a mobile software application programming interface coupled to a modular hardware accessory. It allows the specification of lab-on-chip operation and post-analytic functions at the mobile software layer. We demonstrate its potential by operating a simple lab-on-chip to carry out the detection of dopamine using various electroanalytical methods. PMID:27598208
Peer Assessment of Student-Produced Mechanics Lab Report Videos
ERIC Educational Resources Information Center
Douglas, Scott S.; Aiken, John M.; Lin, Shih-Yin; Greco, Edwin F.; Alicea-Muñoz, Emily; Schatz, Michael F.
2017-01-01
We examine changes in students' rating behavior during a semester-long sequence of peer evaluation laboratory exercises in an introductory mechanics course. We perform a quantitative analysis of the ratings given by students to peers' physics lab reports, and conduct interviews with students. We find that peers persistently assign higher ratings…
Sanati Nezhad, Amir; Naghavi, Mahsa; Packirisamy, Muthukumaran; Bhat, Rama; Geitmann, Anja
2013-01-01
Tip-growing cells have the unique property of invading living tissues and abiotic growth matrices. To do so, they exert significant penetrative forces. In plant and fungal cells, these forces are generated by the hydrostatic turgor pressure. Using the TipChip, a microfluidic lab-on-a-chip device developed for tip-growing cells, we tested the ability to exert penetrative forces generated in pollen tubes, the fastest-growing plant cells. The tubes were guided to grow through microscopic gaps made of elastic polydimethylsiloxane material. Based on the deformation of the gaps, the force exerted by the elongating tubes to permit passage was determined using finite element methods. The data revealed that increasing mechanical impedance was met by the pollen tubes through modulation of the cell wall compliance and, thus, a change in the force acting on the obstacle. Tubes that successfully passed a narrow gap frequently burst, raising questions about the sperm discharge mechanism in the flowering plants. PMID:23630253
Protein in Urine: MedlinePlus Lab Test Information
... Lab Tests Online [Internet]. American Association for Clinical Chemistry; c2001–2017. Pre-eclampsia: Overview [updated 2016 Feb ... Tests Online: Urinalysis [Internet]. American Association for Clinical Chemistry; c2001–2017. Urinalysis: The Test [updated 2016 May ...
State Summary of Soil and Groundwater Cleanup Standards for Hydrocarbons
1993-11-15
821096-01 November 15, 1993 19970425 057 !DISTfRIBUTI STýA-TEM,_ Approved for public release; Distribution Unlbfited Product - Paranmeter/ Lab Test ...Env-mmenal Mantagemen, 20-270-5613 Product Parameter/ Lab Test Protocol Detection Notification Action Clean-up Level Constituent & Number Level Level...Envi-mnentai Managament, 205-270-.5613 Su m r of Alsk Clanu Sadr s fo Hyrcro Cotmiae Groundwater Product- - Parameter/ Lab Test Protocol ’Detection
Foundations of Quantum Mechanics: recent developments at INRIM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Genovese, Marco; Piacentini, Fabrizio
2011-09-23
This paper's purpose is to show some experiments performed in the 'Carlo Novero' labs of the Optics Division of the National Institute of Metrological Research (INRIM, Torino, Italy) in the last years, aiming to discriminate between Standard Quantum Mechanics and some specific, restricted class of Hidden Variable Theories (HVTs).The first experiment, realized in two different configurations, will perform the Alicki - Van Ryn non-classicality test on single particles, in our specific case heralded single photons. The second experiment instead will be on the testing of two restricted Local Realistic Theories (LRTs), properly built to describe polarization entangled photons experiments, whosemore » inequalities are not affected by the detection loophole.« less
Cercenelli, Laura; Tiberi, Guido; Corazza, Ivan; Giannaccare, Giuseppe; Fresina, Michela; Marcelli, Emanuela
2017-01-01
Many open source software packages have been recently developed to expand the usability of eye tracking systems to study oculomotor behavior, but none of these is specifically designed to encompass all the main functions required for creating eye tracking tests and for providing the automatic analysis of saccadic eye movements. The aim of this study is to introduce SacLab, an intuitive, freely-available MATLAB toolbox based on Graphical User Interfaces (GUIs) that we have developed to increase the usability of the ViewPoint EyeTracker (Arrington Research, Scottsdale, AZ, USA) in clinical ophthalmology practice. SacLab consists of four processing modules that enable the user to easily create visual stimuli tests (Test Designer), record saccadic eye movements (Data Recorder), analyze the recorded data to automatically extract saccadic parameters of clinical interest (Data Analyzer) and provide an aggregate analysis from multiple eye movements recordings (Saccade Analyzer), without requiring any programming effort by the user. A demo application of SacLab to carry out eye tracking tests for the analysis of horizontal saccades was reported. We tested the usability of SacLab toolbox with three ophthalmologists who had no programming experience; the ophthalmologists were briefly trained in the use of SacLab GUIs and were asked to perform the demo application. The toolbox gained an enthusiastic feedback from all the clinicians in terms of intuitiveness, ease of use and flexibility. Test creation and data processing were accomplished in 52±21s and 46±19s, respectively, using the SacLab GUIs. SacLab may represent a useful tool to ease the application of the ViewPoint EyeTracker system in clinical routine in ophthalmology. Copyright © 2016 Elsevier Ltd. All rights reserved.
Spackman, Erica; Cardona, Carol; Muñoz-Aguayo, Jeannette; Fleming, Susan
2016-01-01
The US National institutes of Health-Centers of Excellence for Influenza Research and Surveillance is a research consortium that funds numerous labs worldwide to conduct influenza A surveillance in diverse animal species. There is no harmonization of testing procedures among these labs; therefore an external quality assurance (EQA) program was implemented to evaluate testing accuracy among labs in the program in 2012. Accurate detection of novel influenza A variants is crucial because of the broad host range and potentially high virulence of the virus in diverse species. Two molecular detection sample sets and 2 serology sample sets (one with avian origin isolates, and one with mammalian origin isolates each) were made available at approximately six month intervals. Participating labs tested the material in accordance with their own protocols. During a five year period a total of 41 labs from 23 countries ordered a total of 132 avian molecular, 121 mammalian molecular and 90 serology sample sets. Testing was completed by 111 individuals. Detection of type A influenza by RT-PCR was reliable with a pass rate (80% or greater agreement with expected results) of 86.6% for avian and 86.2% for mammalian origin isolates. However, identification of subtype by RT-PCR was relatively poor with 54.1% and 75.9% accuracy for avian and mammalian influenza isolates respectively. Serological testing had an overall pass rate of 86.9% and 22/23 labs used commercial ELISA kits. Based on the results of this EQA program six labs modified their procedures to improve accuracy and one lab identified an unknown equipment problem. These data represent the successful implementation of an international EQA program for an infectious disease; insights into the logistics and test design are also discussed. PMID:27788155
Spackman, Erica; Cardona, Carol; Muñoz-Aguayo, Jeannette; Fleming, Susan
2016-01-01
The US National institutes of Health-Centers of Excellence for Influenza Research and Surveillance is a research consortium that funds numerous labs worldwide to conduct influenza A surveillance in diverse animal species. There is no harmonization of testing procedures among these labs; therefore an external quality assurance (EQA) program was implemented to evaluate testing accuracy among labs in the program in 2012. Accurate detection of novel influenza A variants is crucial because of the broad host range and potentially high virulence of the virus in diverse species. Two molecular detection sample sets and 2 serology sample sets (one with avian origin isolates, and one with mammalian origin isolates each) were made available at approximately six month intervals. Participating labs tested the material in accordance with their own protocols. During a five year period a total of 41 labs from 23 countries ordered a total of 132 avian molecular, 121 mammalian molecular and 90 serology sample sets. Testing was completed by 111 individuals. Detection of type A influenza by RT-PCR was reliable with a pass rate (80% or greater agreement with expected results) of 86.6% for avian and 86.2% for mammalian origin isolates. However, identification of subtype by RT-PCR was relatively poor with 54.1% and 75.9% accuracy for avian and mammalian influenza isolates respectively. Serological testing had an overall pass rate of 86.9% and 22/23 labs used commercial ELISA kits. Based on the results of this EQA program six labs modified their procedures to improve accuracy and one lab identified an unknown equipment problem. These data represent the successful implementation of an international EQA program for an infectious disease; insights into the logistics and test design are also discussed.
Kiechle, Frederick L; Arcenas, Rodney C; Rogers, Linda C
2014-01-01
Benchmarks and metrics related to laboratory test utilization are based on evidence-based medical literature that may suffer from a positive publication bias. Guidelines are only as good as the data reviewed to create them. Disruptive technologies require time for appropriate use to be established before utilization review will be meaningful. Metrics include monitoring the use of obsolete tests and the inappropriate use of lab tests. Test utilization by clients in a hospital outreach program can be used to monitor the impact of new clients on lab workload. A multi-disciplinary laboratory utilization committee is the most effective tool for modifying bad habits, and reviewing and approving new tests for the lab formulary or by sending them out to a reference lab. Copyright © 2013 Elsevier B.V. All rights reserved.
Zhang, Chang-Ping; Gu, Ping; Zhao, Jun; Zhang, Dong; Deng, Yue
2009-08-15
The removal of cesium from an aqueous solution by an adsorption-microfiltration (AMF) process was investigated in jar tests and lab-scale tests. The adsorbent was K(2)Zn(3)[Fe(CN)(6)](2). The obtained cesium data in the jar test fit a Freundlich-type isotherm well. In the lab-scale test, the mean cesium concentration of the raw water and the effluent were 106.87 microg/L and 0.59 microg/L, respectively, the mean removal of cesium was 99.44%, and the mean decontamination factors (DF) and concentration factors (CF) were 208 and 539, respectively. The removal of cesium in the lab-scale test was better than that in the jar test because the old adsorbents remaining in the reactor still had adsorption capacity with the premise of no significant desorption being observed, and the continuous renewal of the adsorbent surface improved the adsorption capacity of the adsorbent. Some of the suspended solids were deposited on the bottom of the reactor, which would affect the mixing of adsorbents with the raw water and the renewing of the adsorbent surface. Membrane fouling was the main physical fouling mechanism, and the cake layer was the main filtration resistance. Specific flux (SF) decreased step by step during the whole period of operation due to membrane fouling and concentration polarization. The quality of the effluent was good and the turbidity remained lower than 0.1NTU, and the toxic anion, CN(-), could not be detected because of its low concentration, this indicated that the effluent was safe. The AMF process was feasible for practical application in the treatment of liquid waste containing cesium.
GeoLab: A Geological Workstation for Future Missions
NASA Technical Reports Server (NTRS)
Evans, Cynthia; Calaway, Michael; Bell, Mary Sue; Li, Zheng; Tong, Shuo; Zhong, Ye; Dahiwala, Ravi
2014-01-01
The GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance theThe GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance the early scientific returns from future missions and ensure that the best samples are selected for Earth return. The facility was also designed to foster the development of instrument technology. Since 2009, when GeoLab design and construction began, the GeoLab team [a group of scientists from the Astromaterials Acquisition and Curation Office within the Astromaterials Research and Exploration Science (ARES) Directorate at JSC] has progressively developed and reconfigured the GeoLab hardware and software interfaces and developed test objectives, which were to 1) determine requirements and strategies for sample handling and prioritization for geological operations on other planetary surfaces, 2) assess the scientific contribution of selective in-situ sample characterization for mission planning, operations, and sample prioritization, 3) evaluate analytical instruments and tools for providing efficient and meaningful data in advance of sample return and 4) identify science operations that leverage human presence with robotic tools. In the first year of tests (2010), GeoLab examined basic glovebox operations performed by one and two crewmembers and science operations performed by a remote science team. The 2010 tests also examined the efficacy of basic sample characterization [descriptions, microscopic imagery, X-ray fluorescence (XRF) analyses] and feedback to the science team. In year 2 (2011), the GeoLab team tested enhanced software and interfaces for the crew and science team (including Web-based and mobile device displays) and demonstrated laboratory configurability with a new diagnostic instrument (the Multispectral Microscopic Imager from the JPL and Arizona State University). In year 3 (2012), the GeoLab team installed and tested a robotic sample manipulator and evaluated robotic-human interfaces for science operations.
Magnetic Viscous Drag for Friction Labs
ERIC Educational Resources Information Center
Gaffney, Chris; Catching, Adam
2016-01-01
The typical friction lab performed in introductory mechanics courses is usually not the favorite of either the student or the instructor. The measurements are not all that easy to make, and reproducibility is usually a troublesome issue. This paper describes the augmentation of such a friction lab with a study of the viscous drag on a magnet…
How Reliable Is Laboratory Testing?
... laboratory testing. (See Who's Who in the Lab .) Post-Analytic Activities After the test is completed, the result must be delivered in ... View Sources NOTE: This article is based on research that ... of the Lab Tests Online Editorial Review Board . This article is periodically ...
Piezoelectric energy harvesting computer controlled test bench
NASA Astrophysics Data System (ADS)
Vázquez-Rodriguez, M.; Jiménez, F. J.; de Frutos, J.; Alonso, D.
2016-09-01
In this paper a new computer controlled (C.C.) laboratory test bench is presented. The patented test bench is made up of a C.C. road traffic simulator, C.C. electronic hardware involved in automating measurements, and test bench control software interface programmed in LabVIEW™. Our research is focused on characterizing electronic energy harvesting piezoelectric-based elements in road traffic environments to extract (or "harvest") maximum power. In mechanical to electrical energy conversion, mechanical impacts or vibrational behavior are commonly used, and several major problems need to be solved to perform optimal harvesting systems including, but no limited to, primary energy source modeling, energy conversion, and energy storage. It is described a novel C.C. test bench that obtains, in an accurate and automatized process, a generalized linear equivalent electrical model of piezoelectric elements and piezoelectric based energy store harvesting circuits in order to scale energy generation with multiple devices integrated in different topologies.
Piezoelectric energy harvesting computer controlled test bench.
Vázquez-Rodriguez, M; Jiménez, F J; de Frutos, J; Alonso, D
2016-09-01
In this paper a new computer controlled (C.C.) laboratory test bench is presented. The patented test bench is made up of a C.C. road traffic simulator, C.C. electronic hardware involved in automating measurements, and test bench control software interface programmed in LabVIEW™. Our research is focused on characterizing electronic energy harvesting piezoelectric-based elements in road traffic environments to extract (or "harvest") maximum power. In mechanical to electrical energy conversion, mechanical impacts or vibrational behavior are commonly used, and several major problems need to be solved to perform optimal harvesting systems including, but no limited to, primary energy source modeling, energy conversion, and energy storage. It is described a novel C.C. test bench that obtains, in an accurate and automatized process, a generalized linear equivalent electrical model of piezoelectric elements and piezoelectric based energy store harvesting circuits in order to scale energy generation with multiple devices integrated in different topologies.
Conducting perception research over the internet: a tutorial review.
Woods, Andy T; Velasco, Carlos; Levitan, Carmel A; Wan, Xiaoang; Spence, Charles
2015-01-01
This article provides an overview of the recent literature on the use of internet-based testing to address important questions in perception research. Our goal is to provide a starting point for the perception researcher who is keen on assessing this tool for their own research goals. Internet-based testing has several advantages over in-lab research, including the ability to reach a relatively broad set of participants and to quickly and inexpensively collect large amounts of empirical data, via services such as Amazon's Mechanical Turk or Prolific Academic. In many cases, the quality of online data appears to match that collected in lab research. Generally-speaking, online participants tend to be more representative of the population at large than those recruited for lab based research. There are, though, some important caveats, when it comes to collecting data online. It is obviously much more difficult to control the exact parameters of stimulus presentation (such as display characteristics) with online research. There are also some thorny ethical elements that need to be considered by experimenters. Strengths and weaknesses of the online approach, relative to others, are highlighted, and recommendations made for those researchers who might be thinking about conducting their own studies using this increasingly-popular approach to research in the psychological sciences.
Conducting perception research over the internet: a tutorial review
Velasco, Carlos; Levitan, Carmel A.; Wan, Xiaoang; Spence, Charles
2015-01-01
This article provides an overview of the recent literature on the use of internet-based testing to address important questions in perception research. Our goal is to provide a starting point for the perception researcher who is keen on assessing this tool for their own research goals. Internet-based testing has several advantages over in-lab research, including the ability to reach a relatively broad set of participants and to quickly and inexpensively collect large amounts of empirical data, via services such as Amazon’s Mechanical Turk or Prolific Academic. In many cases, the quality of online data appears to match that collected in lab research. Generally-speaking, online participants tend to be more representative of the population at large than those recruited for lab based research. There are, though, some important caveats, when it comes to collecting data online. It is obviously much more difficult to control the exact parameters of stimulus presentation (such as display characteristics) with online research. There are also some thorny ethical elements that need to be considered by experimenters. Strengths and weaknesses of the online approach, relative to others, are highlighted, and recommendations made for those researchers who might be thinking about conducting their own studies using this increasingly-popular approach to research in the psychological sciences. PMID:26244107
NASA Technical Reports Server (NTRS)
Bar-Cohen, Yoseph; Sherrit, Stewart; Bao, Xiaoqi; Chang, Zensheu; Lih, Shyh-Shiuh
2004-01-01
Increasingly, electroactive materials are used to produce acutators, sensors, displays and other elements of mechanisms and devices. In recognition of the potential of these materials, research at the JPL's NDEAA Lab have led to many novel space and terrestrial applications. This effort involves mostly the use of piezoelectric and electroactive polymers (EAP).
What Is LAB and Why Was It Renormed?
ERIC Educational Resources Information Center
Abbott, Muriel
A report on the Language Assessment Battery (LAB) explains, in question-and-answer form, the causes and results of some changes made in the test norms. The LAB is a test of communicative language competence, written in English and Spanish versions and used for student placement in the New York City Public Schools. The report describes the test…
Ozone Contamination in Aircraft Cabins: Appendix B: Overview papers. Ozone destruction techniques
NASA Technical Reports Server (NTRS)
Wilder, R.
1979-01-01
Ozone filter test program and ozone instrumentation are presented. Tables on the flight tests, samll scale lab tests, and full scale lab tests were reviewed. Design verification, flammability, vibration, accelerated contamination, life cycle, and cabin air quality are described.
Stewart, Samuel Alan; Penz, Erika; Fenton, Mark; Skomro, Robert
2017-01-01
Obstructive sleep apnea is a common problem, requiring expensive in-lab polysomnography for proper diagnosis. Home monitoring can provide an alternative to in-lab testing for a subset of OSA patients. The objective of this project was to investigate the effect of incorporating home testing into an OSA program at a large, tertiary sleep disorders centre. The Sleep Disorders Centre in Saskatoon, Canada, has been incorporating at-home testing into their diagnostic pathways since 2006. Administrative data from 2007 to 2013 were extracted (10030 patients) and the flow of patients through the program was followed from diagnosis to treatment. Costs were estimated using 2014 pricing and were stratified by disease attributes and sensitivity analysis was applied. The overall costs per patient were $627.40, with $419.20 for at-home testing and $746.20 for in-lab testing. The cost of home management would rise to $515 if all negative tests were required to be confirmed by an in-lab PSG. Our review suggests that at-home testing can be cost-effective alternative to in-lab testing when applied to the correct population, specifically, those with a high pretest probability of obstructive sleep apnea and an absence of significant comorbidities.
GeoLab's First Field Trials, 2010 Desert RATS: Evaluating Tools for Early Sample Characterization
NASA Technical Reports Server (NTRS)
Evans, Cindy A.; Bell, M. S.; Calaway, M. J.; Graff, Trevor; Young, Kelsey
2011-01-01
As part of an accelerated prototyping project to support science operations tests for future exploration missions, we designed and built a geological laboratory, GeoLab, that was integrated into NASA's first generation Habitat Demonstration Unit-1/Pressurized Excursion Module (HDU1-PEM). GeoLab includes a pressurized glovebox for transferring and handling samples collected on geological traverses, and a suite of instruments for collecting preliminary data to help characterize those samples. The GeoLab and the HDU1-PEM were tested for the first time as part of the 2010 Desert Research and Technology Studies (DRATS), NASA's analog field exercise for testing mission technologies. The HDU1- PEM and GeoLab participated in two weeks of joint operations in northern Arizona with two crewed rovers and the DRATS science team.
2001-07-01
hardware - in - loop (HWL) simulation is also developed...Firings / Engine Tests Structure Test Hardware In - Loop Simulation Subsystem Test Lab Tests Seeker Actuators Sensors Electronics Propulsion Model Aero Model...Structure Test Hardware In - Loop Simulation Subsystem Test Lab Tests Seeker Actuators Sensors Electronics Propulsion Model Aero Model Model
Integration of MSFC Usability Lab with Usability Testing
NASA Technical Reports Server (NTRS)
Cheng, Yiwei; Richardson, Sally
2010-01-01
As part of the Stage Analysis Branch, human factors engineering plays an important role in relating humans to the systems of hardware and structure designs of the new launch vehicle. While many branches are involved in the technical aspects of creating a launch vehicle, human factors connects humans to the scientific systems with the goal of improving operational performance and safety while reducing operational error and damage to the hardware. Human factors engineers use physical and computerized models to visualize possible areas for improvements to ensure human accessibility to components requiring maintenance and that the necessary maintenance activities can be accomplished with minimal risks to human and hardware. Many methods of testing are used to fulfill this goal, such as physical mockups, computerized visualization, and usability testing. In this analysis, a usability test is conducted to test how usable a website is to users who are and are not familiar with it. The testing is performed using participants and Morae software to record and analyze the results. This analysis will be a preliminary test of the usability lab in preparation for use in new spacecraft programs, NASA Enterprise, or other NASA websites. The usability lab project is divided into two parts: integration of the usability lab and a preliminary test of the usability lab.
Koster-Brouwer, Maria E; Verboom, Diana M; Scicluna, Brendon P; van de Groep, Kirsten; Frencken, Jos F; Janssen, Davy; Schuurman, Rob; Schultz, Marcus J; van der Poll, Tom; Bonten, Marc J M; Cremer, Olaf L
2018-03-01
Discrimination between infectious and noninfectious causes of acute respiratory failure is difficult in patients admitted to the ICU after a period of hospitalization. Using a novel biomarker test (SeptiCyte LAB), we aimed to distinguish between infection and inflammation in this population. Nested cohort study. Two tertiary mixed ICUs in the Netherlands. Hospitalized patients with acute respiratory failure requiring mechanical ventilation upon ICU admission from 2011 to 2013. Patients having an established infection diagnosis or an evidently noninfectious reason for intubation were excluded. None. Blood samples were collected upon ICU admission. Test results were categorized into four probability bands (higher bands indicating higher infection probability) and compared with the infection plausibility as rated by post hoc assessment using strict definitions. Of 467 included patients, 373 (80%) were treated for a suspected infection at admission. Infection plausibility was classified as ruled out, undetermined, or confirmed in 135 (29%), 135 (29%), and 197 (42%) patients, respectively. Test results correlated with infection plausibility (Spearman's rho 0.332; p < 0.001). After exclusion of undetermined cases, positive predictive values were 29%, 54%, and 76% for probability bands 2, 3, and 4, respectively, whereas the negative predictive value for band 1 was 76%. Diagnostic discrimination of SeptiCyte LAB and C-reactive protein was similar (p = 0.919). Among hospitalized patients admitted to the ICU with clinical uncertainty regarding the etiology of acute respiratory failure, the diagnostic value of SeptiCyte LAB was limited.
ERIC Educational Resources Information Center
Han, Duanduan; Ugaz, Victor
2017-01-01
Three self-contained mini-labs were integrated into a core undergraduate fluid mechanics course, with the goal of delivering hands-on content in a manner scalable to large class sizes. These mini-labs supported learning objectives involving friction loss in pipes, flow measurement, and centrifugal pump analysis. The hands-on experiments were…
ERIC Educational Resources Information Center
Marshall, Pamela A.
2007-01-01
In our Fundamentals of Genetics lab, students perform a wide variety of labs to reinforce and extend the topics covered in lecture. I developed an active-learning lab to augment the lecture topic of mutagenesis. In this lab exercise, students determine if a compound they bring from home is a mutagen. Students are required to read extensive…
ERLN Lab Compendium Fact Sheet
The Compendium is an online database of environmental testing laboratories nationwide. It enables labs to create profiles of their capabilities, so emergency responders can quickly identify a lab that will meet their support needs.
... hours. Normal value ranges may vary slightly from one lab to another. Some labs use different measurements or test different samples. Talk to your provider about the meaning of your specific test results. What Abnormal Results Mean An increased level of urinary delta-ALA may ...
2017-10-01
for all project Aims. Timeline- months 3-6. Status: completed. Task 6: Complete primary analyses and hypothesis testing for Aim 2, including...glucose. For each of these lab tests , each VA site can name them something different and can change names over times. Labs should be linked to Logical...Observation Identifiers Names (LOINC) codes, an international standard system that assigns a numeric code to specific lab tests . However, VA data
Leyland, Rebecca; Freedman, Danielle B
2016-11-01
Background Lab Tests Online-UK celebrated its 10th anniversary in 2014 and to mark the occasion the first comprehensive survey of website users was undertaken. Methods A pop-up box with a link to Survey Monkey was used to offer website users the chance to participate in the survey, which was live from 4 March 2014 to 11 April 2014. Results Six hundred and sixty-one participants started the questionnaire and 338 completed all of the demographic questions. Although the website is designed and aimed at patients and the public, a significant number of respondents were health-care professionals (47%). The majority of survey participants found the Lab Tests Online-UK website via a search engine and were visiting the site for themselves. The majority of participants found what they were looking for on the website and found the information very easy or fairly easy to understand. The patient respondents were keen to see their laboratory test results (87%), but the majority did not have access (60%) at the time of the survey. Conclusions This survey provides good evidence that the Lab Tests Online-UK website is a useful resource for patients and health-care professionals alike. It comes at a poignant time as the release of results direct to patients starts with access to their medical records. The Lab Tests Online-UK website has a key role in enabling patients to understand their lab test results, and therefore empowering them to take an interest and engage in their own healthcare.
Photocopy of photograph (original negative located in LBNL Photo Lab ...
Photocopy of photograph (original negative located in LBNL Photo Lab Collection). March 2005. GENERATOR ROOM, MECHANICAL SECTION, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA
Photocopy of photograph (original negative located in LBNL Photo Lab ...
Photocopy of photograph (original negative located in LBNL Photo Lab Collection). March 2005. SWITCHGEAR, MECHANICAL SECTION, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA
Technical memo, project 0-6132 : task 6 - test sections in the districts.
DOT National Transportation Integrated Search
2011-01-01
This Tech Memo provides a summary of the Lab Test, Distress Survey, and Construction Reports : for the RAP Test Sections in Laredo District. Based on extensive lab testing by TTI, the District : elected to use the TTI mix-design (5.0% PG 64-22 + Crus...
Development and flight testing of UV optimized Photon Counting CCDs
NASA Astrophysics Data System (ADS)
Hamden, Erika T.
2018-06-01
I will discuss the latest results from the Hamden UV/Vis Detector Lab and our ongoing work using a UV optimized EMCCD in flight. Our lab is currently testing efficiency and performance of delta-doped, anti-reflection coated EMCCDs, in collaboration with JPL. The lab has been set-up to test quantum efficiency, dark current, clock-induced-charge, and read noise. I will describe our improvements to our circuit boards for lower noise, updates from a new, more flexible NUVU controller, and the integration of an EMCCD in the FIREBall-2 UV spectrograph. I will also briefly describe future plans to conduct radiation testing on delta-doped EMCCDs (both warm, unbiased and cold, biased configurations) thus summer and longer term plans for testing newer photon counting CCDs as I move the HUVD Lab to the University of Arizona in the Fall of 2018.
Looking North into Lab Metallurgy Testing Area and Enrichment Motor ...
Looking North into Lab Metallurgy Testing Area and Enrichment Motor within Recycle Recovery Building - Hematite Fuel Fabrication Facility, Recycle Recovery Building, 3300 State Road P, Festus, Jefferson County, MO
The Development of MSFC Usability Lab
NASA Technical Reports Server (NTRS)
Cheng, Yiwei; Richardson, Sally
2010-01-01
This conference poster reviews the development of the usability lab at Marshall Space Flight Center. The purpose of the lab was to integrate a fully functioning usability laboratory to provide a resource for future human factor assessments. and to implement preliminary usability testing on a MSFC website to validate the functionality of the lab.
LabLessons: Effects of Electronic Prelabs on Student Engagement and Performance
ERIC Educational Resources Information Center
Gryczka, Patrick; Klementowicz, Edward; Sharrock, Chappel; Maxfield, MacRae; Montclare, Jin Kim
2016-01-01
Lab instructors, for both high school and undergraduate college level courses, face issues of constricted time within the lab period and limited student engagement with prelab materials. To address these issues, an online prelab delivery system named LabLessons is developed and tested out in a high school chemistry classroom. The system…
Introductory labs; what they don't, should, and can teach (and why)
NASA Astrophysics Data System (ADS)
Wieman, Carl
2016-03-01
Introductory physics labs are widely used and expensive. They have a wide variety of potential learning goals, but these are seldom specified and less often measured if they are achieved. We cover three different research projects on introductory labs: 1) We have done cognitive task analyses of both experimental research in physics and instructional labs. The striking differences explain much of the unhappiness expressed by students with labs: 2) We have measured the effectiveness of two introductory physics lab courses specifically intended to teach the physics content covered in standard introductory courses on mechanics and E & M. As measured by course exams, the benefit is 0 +/-2% for both. 3) We show how it is possible to use lab courses to teach students to correctly evaluate physical models with uncertain data. Such quantitative critical thinking is an important skill that is not learned in typical lab courses, but is well learned by our modified lab instruction.
Implementation of the Web-based laboratory
NASA Astrophysics Data System (ADS)
Ying, Liu; Li, Xunbo
2005-12-01
With the rapid developments of Internet technologies, remote access and control via Internet is becoming a reality. A realization of the web-based laboratory (the W-LAB) was presented. The main target of the W-LAB was to allow users to easily access and conduct experiments via the Internet. While realizing the remote communication, a system, which adopted the double client-server architecture, was introduced. It ensures the system better security and higher functionality. The experimental environment implemented in the W-Lab was integrated by both virtual lab and remote lab. The embedded technology in the W-LAB system as an economical and efficient way to build the distributed infrastructural network was introduced. Furthermore, by introducing the user authentication mechanism in the system, it effectively secures the remote communication.
An analysis of high school students' perceptions and academic performance in laboratory experiences
NASA Astrophysics Data System (ADS)
Mirchin, Robert Douglas
This research study is an investigation of student-laboratory (i.e., lab) learning based on students' perceptions of experiences using questionnaire data and evidence of their science-laboratory performance based on paper-and-pencil assessments using Maryland-mandated criteria, Montgomery County Public Schools (MCPS) criteria, and published laboratory questions. A 20-item questionnaire consisting of 18 Likert-scale items and 2 open-ended items that addressed what students liked most and least about lab was administered to students before labs were observed. A pre-test and post-test assessing laboratory achievement were administered before and after the laboratory experiences. The three labs observed were: soda distillation, stoichiometry, and separation of a mixture. Five significant results or correlations were found. For soda distillation, there were two positive correlations. Student preference for analyzing data was positively correlated with achievement on the data analysis dimension of the lab rubric. A student preference for using numbers and graphs to analyze data was positively correlated with achievement on the analysis dimension of the lab rubric. For the separating a mixture lab data the following pairs of correlations were significant. Student preference for doing chemistry labs where numbers and graphs were used to analyze data had a positive correlation with writing a correctly worded hypothesis. Student responses that lab experiences help them learn science positively correlated with achievement on the data dimension of the lab rubric. The only negative correlation found related to the first result where students' preference for computers was inversely correlated to their performance on analyzing data on their lab report. Other findings included the following: students like actual experimental work most and the write-up and analysis of a lab the least. It is recommended that lab science instruction be inquiry-based, hands-on, and that students be tested for lab content acquisition. The final conclusion of the study is that students expressed a preference for working in groups and working with materials and equipment as opposed to individual, non-group work and analyzing data.
The Dark Matter of Lab Work: Illuminating the Negotiation of Disciplined Perception in Mechanics
ERIC Educational Resources Information Center
Lindwall, Oskar; Lymer, Gustav
2008-01-01
This study examines the practical work of a pair of students and an instructor using probeware in a mechanics lab. The aim of the study is to describe and discuss a type of interactional sequence that we refer to as "dark matter", the ordinary backdrop to the extraordinary sequences that are easily recognizable as clear-cut instances of learning.…
Commerce Lab - An enabling facility and test bed for commercial flight opportunities
NASA Technical Reports Server (NTRS)
Robertson, Jack; Atkins, Harry L.; Williams, John R.
1986-01-01
Commerce Lab is conceived as an adjunct to the National Space Transportation System (NSTS) by providing a focal point for commercial missions which could utilize existing NSTS carrier and resource capabilities for on-orbit experimentation in the microgravity sciences. In this context, the Commerce Lab provides an enabling facility and test bed for commercial flight opportunities. Commerce Lab program activities to date have focused on mission planning for private sector involvement in the space program to facilitate the commercial exploitation of the microgravity environment for materials processing research and development. It is expected that Commerce Lab will provide a logical transition between currently planned NSTS missions and future microgravity science and commercial R&D missions centered around the Space Station. The present study identifies candidate Commerce Lab flight experiments and their development status and projects a mission traffic model that can be used in commercial mission planning.
Humbert, H; Machinal, C; Labaye, Ivan; Schrotter, J C
2011-01-01
The determination of the virus retention capabilities of UF units during operation is essential for the operators of drinking water treatment facilities in order to guarantee an efficient and stable removal of viruses through time. In previous studies, an effective method (MS2-phage challenge tests) was developed by the Water Research Center of Veolia Environnement for the measurement of the virus retention rates (Log Removal Rate, LRV) of commercially available hollow fiber membranes at lab scale. In the present work, the protocol for monitoring membrane performance was transferred from lab scale to pilot scale. Membrane performances were evaluated during pilot trial and compared to the results obtained at lab scale with fibers taken from the pilot plant modules. PFU culture method was compared to RT-PCR method for the calculation of LRV in both cases. Preliminary tests at lab scale showed that both methods can be used interchangeably. For tests conducted on virgin membrane, a good consistency was observed between lab and pilot scale results with the two analytical methods used. This work intends to show that a reliable determination of the membranes performances based on RT-PCR analytical method can be achieved during the operation of the UF units.
Blood in Urine: MedlinePlus Lab Test Information
... Information → Blood in Urine URL of this page: https://medlineplus.gov/labtests/bloodinurine.html Blood in Urine ... 2017 Mar 14]; [about 4 screens]: Available from: https://labtestsonline.org/understanding/analytes/urinalysis/tab/test Lab ...
Experimental Results for Titan Aerobot Thermo-Mechanical Subsystem Development
NASA Technical Reports Server (NTRS)
Hall, Jeffrey L.; Jones, J. A.; Kerzhanovich, V. V.; Lachenmeier, T.; Mahr, P.; Pauken, M.; Plett, G. A.; Smith, L.; VanLuvender, M. L.; Yavrouian, A. H.
2006-01-01
This paper describes experimental results from a development program focused in maturing Titan aerobot technology in the areas of mechanical and thermal subsystems. Results from four key activities are described: first, a cryogenic balloon materials development program involving coupon and cylinder tests and culminating in the fabrication and testing of an inflated 4.6 m long prototype blimp at 93 K; second, a combined lab experiment and numerical simulation effort to assess potential problems resulting from radioisotope thermal generator waste heat generation near an inflated blimp; third, an aerial deployment and inflation development program consisting of laboratory and helicopter drop tests on a near full scale (11 m long) prototype blimp; and fourth, a proof of concept experiment demonstrating the viability of using a mechanically steerable high gain antenna on a floating blimp to perform direct to Earth telecommunications from Titan. The paper provides details on all of these successful activities and discusses their impact on the overall effort to produce mature systems technology for future Titan aerobot missions.
78 FR 60245 - Privacy Act Systems of Records; LabWare Laboratory Information Management System
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-01
... Services Laboratories (NVSL). Diagnostic testing provides official test results for animal imports, exports.... Diagnostic testing is also done in connection with suspected foreign animal disease investigations and... of Records; LabWare Laboratory Information Management System AGENCY: Animal and Plant Health...
Photocopy of photograph (original negative located in LBNL Photo Lab ...
Photocopy of photograph (original negative located in LBNL Photo Lab Collection). March 2005. GENERATOR MOTORS OPPOSITE SWITCHGEAR RACKS, MECHANIC SECTION, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA
Photocopy of photograph (original negative located in LBNL Photo Lab ...
Photocopy of photograph (original negative located in LBNL Photo Lab Collection). March 2005. SWITCHGEAR AND POWER GENERATOR MOTORS, MECHANICAL SECTION, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA
Olofsson, Tobias C; Butler, Èile; Markowicz, Pawel; Lindholm, Christina; Larsson, Lennart; Vásquez, Alejandra
2016-10-01
Could honeybees' most valuable contribution to mankind besides pollination services be alternative tools against infections? Today, due to the emerging antibiotic-resistant pathogens, we are facing a new era of searching for alternative tools against infections. Natural products such as honey have been applied against human's infections for millennia without sufficient scientific evidence. A unique lactic acid bacterial (LAB) microbiota was discovered by us, which is in symbiosis with honeybees and present in large amounts in fresh honey across the world. This work investigates if the LAB symbionts are the source to the unknown factors contributing to honey's properties. Hence, we tested the LAB against severe wound pathogens such as methicillin-resistant Staphylococcus aureus (MRSA), Pseudomonas aeruginosa and vancomycin-resistant Enterococcus (VRE) among others. We demonstrate a strong antimicrobial activity from each symbiont and a synergistic effect, which counteracted all the tested pathogens. The mechanisms of action are partly shown by elucidating the production of active compounds such as proteins, fatty acids, anaesthetics, organic acids, volatiles and hydrogen peroxide. We show that the symbionts produce a myriad of active compounds that remain in variable amounts in mature honey. Further studies are now required to investigate if these symbionts have a potential in clinical applications as alternative tools against topical human and animal infections. © 2014 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Sevillano, Enrique; Sun, Rui; Perera, Ricardo
2016-01-01
The use of piezoelectric ceramic transducers (such as Lead-Zirconate-Titanate—PZT) has become more and more widespread for Structural Health Monitoring (SHM) applications. Among all the techniques that are based on this smart sensing solution, guided waves and electro-mechanical impedance techniques have found wider acceptance, and so more studies and experimental works can be found containing these applications. However, even though these two techniques can be considered as complementary to each other, little work can be found focused on the combination of them in order to define a new and integrated damage detection procedure. In this work, this combination of techniques has been studied by proposing a new integrated damage indicator based on Electro-Mechanical Power Dissipation (EMPD). The applicability of this proposed technique has been tested through different experimental tests, with both lab-scale and real-scale structures. PMID:27164104
Sevillano, Enrique; Sun, Rui; Perera, Ricardo
2016-05-05
The use of piezoelectric ceramic transducers (such as Lead-Zirconate-Titanate-PZT) has become more and more widespread for Structural Health Monitoring (SHM) applications. Among all the techniques that are based on this smart sensing solution, guided waves and electro-mechanical impedance techniques have found wider acceptance, and so more studies and experimental works can be found containing these applications. However, even though these two techniques can be considered as complementary to each other, little work can be found focused on the combination of them in order to define a new and integrated damage detection procedure. In this work, this combination of techniques has been studied by proposing a new integrated damage indicator based on Electro-Mechanical Power Dissipation (EMPD). The applicability of this proposed technique has been tested through different experimental tests, with both lab-scale and real-scale structures.
American Association for Clinical Chemistry
... did not need additional cardiac testing. Read the study LAB TESTS ONLINE USPSTF Updates Draft Recommendations on Cervical Cancer ... to follow colleagues and receive updates when they post in a forum, as well as enhanced email and messaging tools. Search ... AACC Programs and Partners Lab Tests Online Harmonization.net Commission on Accreditation in Clinical ...
Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro
2013-12-01
Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.
Photocopy of photograph (original negative located in LBNL Photo Lab ...
Photocopy of photograph (original negative located in LBNL Photo Lab Collection). March 2005. STAIRWAY FROM MAIN FLOOR TO SECOND FLOOR OF MECHANICAL WINE, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA
Photocopy of photograph (digital image located in LBNL Photo Lab ...
Photocopy of photograph (digital image located in LBNL Photo Lab Collection, XBD200503-00117-043). March 2005. MOUSE AT EAST TANGENT, PLUNGING MECHANISM, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA
Fan, Qin; Liu, Shuliang; Li, Juan; Huang, Tingting
2012-05-01
To analyze the antimicrobial susceptibility of lactic acid bacteria (LAB) from yogurt, and to provide references for evaluating the safety of LAB and screening safe strains. The sensitivity of 43 LAB strains, including 14 strains of Streptococcus thermophilus, 12 strains of Lactobacillus acidophilus, 9 strains of Lactobacillus bulgaricus and 8 strains of Bifidobacterium, to 22 antibiotics were tested by agar plate dilution method. All 43 LAB strains were resistant to trimethoprim, nalidixic acid, ciprofloxacin, lomefloxacin, danofloxacin and polymyxin E. Their resistances to kanamycin, tetracycline, clindamycin, doxycycline and cephalothin were varied. The sensitivity to other antibiotics were sensitive or moderate. All isolates were multidrug-resistant. The antimicrobial resistance of tested LAB strains was comparatively serious, and continuously monitoring their antimicrobial resistance and evaluating their safety should be strengthened.
Yen, Yi-Chun; Anderzhanova, Elmira; Bunck, Mirjam; Schuller, Julia; Landgraf, Rainer; Wotjak, Carsten T
2013-01-01
We established mouse models of extremes in trait anxiety, which are based on selective breeding for low vs. normal vs. high open-arm exploration on the elevated plus-maze. Genetically selected low anxiety-related behavior (LAB) coincided with hyperactivity in the home cage. Given the fact that several psychiatric disorders such as schizophrenia, mania, and attention deficit hyperactivity disorder (ADHD) share hyperactivity symptom, we systematically examined LAB mice with respect to unique and overlapping endophenotypes of the three diseases. To this end Venn diagrams were used as an instrument for discrimination of possible models. We arranged the endophenotypes in Venn diagrams and translated them into different behavioral tests. LAB mice showed elevated levels of locomotion in the open field (OF) test with deficits in habituation, compared to mice bred for normal (NAB) and high anxiety-related behavior (HAB). Cross-breeding of hypoactive HAB and hyperactive LAB mice resulted in offspring showing a low level of locomotion comparable to HAB mice, indicating that the HAB alleles are dominant over LAB alleles in determining the level of locomotion. In a holeboard test, LAB mice spent less time in hole exploration, as shown in patients with schizophrenia and ADHD; however, LAB mice displayed no impairments in social interaction and prepulse inhibition (PPI), implying a unlikelihood of LAB as an animal model of schizophrenia. Although LAB mice displayed hyperarousal, active coping styles, and cognitive deficits, symptoms shared by mania and ADHD, they failed to reveal the classic manic endophenotypes, such as increased hedonia and object interaction. The neuroleptic haloperidol reduced locomotor activity in all mouse lines. The mood stabilizer lithium and the psychostimulant amphetamine, in contrast, selectively reduced hyperactivity in LAB mice. Based on the behavioral and pharmacological profiles, LAB mice are suggested as a novel rodent model of ADHD-like symptoms.
Yen, Yi-Chun; Anderzhanova, Elmira; Bunck, Mirjam; Schuller, Julia; Landgraf, Rainer; Wotjak, Carsten T.
2013-01-01
We established mouse models of extremes in trait anxiety, which are based on selective breeding for low vs. normal vs. high open-arm exploration on the elevated plus-maze. Genetically selected low anxiety-related behavior (LAB) coincided with hyperactivity in the home cage. Given the fact that several psychiatric disorders such as schizophrenia, mania, and attention deficit hyperactivity disorder (ADHD) share hyperactivity symptom, we systematically examined LAB mice with respect to unique and overlapping endophenotypes of the three diseases. To this end Venn diagrams were used as an instrument for discrimination of possible models. We arranged the endophenotypes in Venn diagrams and translated them into different behavioral tests. LAB mice showed elevated levels of locomotion in the open field (OF) test with deficits in habituation, compared to mice bred for normal (NAB) and high anxiety-related behavior (HAB). Cross-breeding of hypoactive HAB and hyperactive LAB mice resulted in offspring showing a low level of locomotion comparable to HAB mice, indicating that the HAB alleles are dominant over LAB alleles in determining the level of locomotion. In a holeboard test, LAB mice spent less time in hole exploration, as shown in patients with schizophrenia and ADHD; however, LAB mice displayed no impairments in social interaction and prepulse inhibition (PPI), implying a unlikelihood of LAB as an animal model of schizophrenia. Although LAB mice displayed hyperarousal, active coping styles, and cognitive deficits, symptoms shared by mania and ADHD, they failed to reveal the classic manic endophenotypes, such as increased hedonia and object interaction. The neuroleptic haloperidol reduced locomotor activity in all mouse lines. The mood stabilizer lithium and the psychostimulant amphetamine, in contrast, selectively reduced hyperactivity in LAB mice. Based on the behavioral and pharmacological profiles, LAB mice are suggested as a novel rodent model of ADHD-like symptoms. PMID:23966915
Use and Evaluation of 3D GeoWall Visualizations in Undergraduate Space Science Classes
NASA Astrophysics Data System (ADS)
Turner, N. E.; Hamed, K. M.; Lopez, R. E.; Mitchell, E. J.; Gray, C. L.; Corralez, D. S.; Robinson, C. A.; Soderlund, K. M.
2005-12-01
One persistent difficulty many astronomy students face is the lack of 3- dimensional mental model of the systems being studied, in particular the Sun-Earth-Moon system. Students without such a mental model can have a very hard time conceptualizing the geometric relationships that cause, for example, the cycle of lunar phases or the pattern of seasons. The GeoWall is a recently developed and affordable projection mechanism for three-dimensional stereo visualization which is becoming a popular tool in classrooms and research labs for use in geology classes, but as yet very little work has been done involving the GeoWall for astronomy classes. We present results from a large study involving over 1000 students of varied backgrounds: some students were tested at the University of Texas at El Paso, a large public university on the US-Mexico border and other students were from the Florida Institute of Technology, a small, private, technical school in Melbourne Florida. We wrote a lecture tutorial-style lab to go along with a GeoWall 3D visual of the Earth-Moon system and tested the students before and after with several diagnostics. Students were given pre and post tests using the Lunar Phase Concept Inventory (LPCI) as well as a separate evaluation written specifically for this project. We found the lab useful for both populations of students, but not equally effective for all. We discuss reactions from the students and their improvement, as well as whether the students are able to correctly assess the usefullness of the project for their own learning.
EUSO@TurLab: An experimental replica of ISS orbits
NASA Astrophysics Data System (ADS)
Bertaina, M.; Bowaire, A.; Cambursano, S.; Caruso, R.; Contino, G.; Cotto, G.; Crivello, F.; Forza, R.; Guardone, N.; Manfrin, M.; Mignone, M.; Mulas, R.; Suino, G.; Tibaldi, P. S.
2015-03-01
The EUSO@TurLab project is an on-going activity aimed to reproduce atmospheric and luminous conditions that JEM-EUSO will encounter on its orbits around the Earth. The use of the TurLab facility, part of the Department of Physics of the University of Torino, allows the simulation of different surface conditions in a very dark and rotating environment in order to test the response of JEM-EUSO's sensors and sensitivity. The experimental setup currently in operation has been used to check the potential of the TurLab facility for the above purposes, and the acquired data will be used to test the concept of JEM-EUSO's trigger system.
NASA Astrophysics Data System (ADS)
Browning, S.
2014-12-01
The Math You Need (TMYN) modules were introduced at Baylor University in fall 2012 to address issues of math anxiety common among freshmen non-majors completing their lab science requirement, and to reduce lab time spent reviewing basic math concepts. Modules and associated assessment questions commonly use geoscience examples to illustrate the mathematical principles involved, reinforcing topics addressed in lab. Large enrollments in the course selected for these modules necessitate multiple graduate teaching assistants in the lab, making the online nature of the modules and minimal required involvement of the teaching assistants even more valuable. Students completed three selected modules before encountering associated topics in lab, as well as a pre and post-test to gauge improvement. This presentation will review lessons learned and changes made in the first two years of TMYN at Baylor. Results indicate continued increases in mean pre to post test scores (e.g. 3.2% in fall 2012 to 11.9% in spring 2014), percentage of student pre to post- test improvement (59% in fall 2012 to 72% in spring 2014) and student participation (95 in fall 2012 to 186 in spring 2014). Continued use of these modules is anticipated.
GeoLab 2011: New Instruments and Operations Tested at Desert RATS
NASA Technical Reports Server (NTRS)
Evans, Cindy A.; Calaway, M. J.; Bell, M. S.
2012-01-01
GeoLab is a geological laboratory and testbed designed for supporting geoscience activities during NASA's analog demonstrations. Scientists at NASA's Johnson Space Center built GeoLab as part of a technology project to aid the development of science operational concepts for future planetary surface missions [1, 2, 3]. It is integrated into NASA's Habitat Demonstration Unit, a first generation exploration habitat test article. As a prototype workstation, GeoLab provides a high fidelity working space for analog mission crewmembers to perform in-situ characterization of geologic samples and communicate their findings with supporting scientists. GeoLab analog operations can provide valuable data for assessing the operational and scientific considerations of surface-based geologic analyses such as preliminary examination of samples collected by astronaut crews [4, 5]. Our analog tests also feed into sample handling and advanced curation operational concepts and procedures that will, ultimately, help ensure that the most critical samples are collected during future exploration on a planetary surface, and aid decisions about sample prioritization, sample handling and return. Data from GeoLab operations also supports science planning during a mission by providing additional detailed geologic information to supporting scientists, helping them make informed decisions about strategies for subsequent sample collection opportunities.
NASA Astrophysics Data System (ADS)
Malik, A.; Setiawan, A.; Suhandi, A.; Permanasari, A.; Samsudin, A.; Safitri, D.; Lisdiani, S. A. S.; Sapriadil, S.; Hermita, N.
2018-05-01
This research purposes to explore the used of Higher Order Thinking Laboratory (HOT-Lab) in enhancing the critical thinking skills of pre-service teachers related to the topic of Resistors, Inductors, Capacitor (RLC circuit). This study utilised a quasi-experiment method with Pretest-Posttest Control Group design. The sample of the study was 60 students that were divided into two groups covering in experiment and control group, consists of 30 students. The instrument for measuring critical thinking skills is essay test. Data has been analyzed using normalized gain average, effect size, and t-test. The results show that students’ critical thinking skills using the HOT Lab are higher than the verification lab. Using HOT-lab was implemented in the form of activity in the laboratory can improve high-order thinking skills. Hence, it was concluded that the use of HOT Lab had a greater impact on improving students’ critical thinking skills on RLC topic. Finally, HOT Lab can be used for other physics topics.
Evaluation of direct-to-consumer low-volume lab tests in healthy adults.
Kidd, Brian A; Hoffman, Gabriel; Zimmerman, Noah; Li, Li; Morgan, Joseph W; Glowe, Patricia K; Botwin, Gregory J; Parekh, Samir; Babic, Nikolina; Doust, Matthew W; Stock, Gregory B; Schadt, Eric E; Dudley, Joel T
2016-05-02
Clinical laboratory tests are now being prescribed and made directly available to consumers through retail outlets in the USA. Concerns with these test have been raised regarding the uncertainty of testing methods used in these venues and a lack of open, scientific validation of the technical accuracy and clinical equivalency of results obtained through these services. We conducted a cohort study of 60 healthy adults to compare the uncertainty and accuracy in 22 common clinical lab tests between one company offering blood tests obtained from finger prick (Theranos) and 2 major clinical testing services that require standard venipuncture draws (Quest and LabCorp). Samples were collected in Phoenix, Arizona, at an ambulatory clinic and at retail outlets with point-of-care services. Theranos flagged tests outside their normal range 1.6× more often than other testing services (P < 0.0001). Of the 22 lab measurements evaluated, 15 (68%) showed significant interservice variability (P < 0.002). We found nonequivalent lipid panel test results between Theranos and other clinical services. Variability in testing services, sample collection times, and subjects markedly influenced lab results. While laboratory practice standards exist to control this variability, the disparities between testing services we observed could potentially alter clinical interpretation and health care utilization. Greater transparency and evaluation of testing technologies would increase their utility in personalized health management. This work was supported by the Icahn Institute for Genomics and Multiscale Biology, a gift from the Harris Family Charitable Foundation (to J.T. Dudley), and grants from the NIH (R01 DK098242 and U54 CA189201, to J.T. Dudley, and R01 AG046170 and U01 AI111598, to E.E. Schadt).
Evaluation of direct-to-consumer low-volume lab tests in healthy adults
Kidd, Brian A.; Hoffman, Gabriel; Zimmerman, Noah; Li, Li; Morgan, Joseph W.; Glowe, Patricia K.; Botwin, Gregory J.; Parekh, Samir; Babic, Nikolina; Doust, Matthew W.; Stock, Gregory B.; Schadt, Eric E.; Dudley, Joel T.
2016-01-01
BACKGROUND. Clinical laboratory tests are now being prescribed and made directly available to consumers through retail outlets in the USA. Concerns with these test have been raised regarding the uncertainty of testing methods used in these venues and a lack of open, scientific validation of the technical accuracy and clinical equivalency of results obtained through these services. METHODS. We conducted a cohort study of 60 healthy adults to compare the uncertainty and accuracy in 22 common clinical lab tests between one company offering blood tests obtained from finger prick (Theranos) and 2 major clinical testing services that require standard venipuncture draws (Quest and LabCorp). Samples were collected in Phoenix, Arizona, at an ambulatory clinic and at retail outlets with point-of-care services. RESULTS. Theranos flagged tests outside their normal range 1.6× more often than other testing services (P < 0.0001). Of the 22 lab measurements evaluated, 15 (68%) showed significant interservice variability (P < 0.002). We found nonequivalent lipid panel test results between Theranos and other clinical services. Variability in testing services, sample collection times, and subjects markedly influenced lab results. CONCLUSION. While laboratory practice standards exist to control this variability, the disparities between testing services we observed could potentially alter clinical interpretation and health care utilization. Greater transparency and evaluation of testing technologies would increase their utility in personalized health management. FUNDING. This work was supported by the Icahn Institute for Genomics and Multiscale Biology, a gift from the Harris Family Charitable Foundation (to J.T. Dudley), and grants from the NIH (R01 DK098242 and U54 CA189201, to J.T. Dudley, and R01 AG046170 and U01 AI111598, to E.E. Schadt). PMID:27018593
Advanced Ceramics Property Measurements
NASA Technical Reports Server (NTRS)
Salem, Jonathan; Helfinstine, John; Quinn, George; Gonczy, Stephen
2013-01-01
Mechanical and physical properties of ceramic bodies can be difficult to measure correctly unless the proper techniques are used. The Advanced Ceramics Committee of ASTM, C-28, has developed dozens of consensus test standards and practices to measure various properties of a ceramic monolith, composite, or coating. The standards give the "what, how, how not, and why" for measurement of many mechanical, physical, thermal, and performance properties. Using these standards will provide accurate, reliable, and complete data for rigorous comparisons with other test results from your test lab, or another. The C-28 Committee has involved academics, producers, and users of ceramics to write and continually update more than 45 standards since the committee's inception in 1986. Included in this poster is a pictogram of the C-28 standards and information on how to obtain individual copies with full details or the complete collection of standards in one volume.
Transport Powder and Liquid Samples by Surface Acoustic Waves
NASA Technical Reports Server (NTRS)
Bao, Xiaoqi; Bar-Cohen, Yoseph; Sherrit, Stewart; Badescu, Mircea; Louyeh, Sahar
2009-01-01
Sample transport is an important requirement for In-situ analysis of samples in NASA planetary exploration missions. Tests have shown that powders or liquid drops on a surface can be transported by surface acoustic waves (SAW) that are generated on the surface using interdigital transducers. The phenomena were investigated experimentally and to generate SAWs interdigital electrodes were deposited on wafers of 128 deg rotated Y-cut LiNbO?. Transporting capability of the SAW device was tested using particles of various sizes and drops of various viscosities liquids. Because of different interaction mechanisms with the SAWs, the powders and the liquid drops were observed to move in opposite directions. In the preliminary tests, a speed of 180 mm/s was achieved for powder transportation. The detailed experimental setup and results are presented in this paper. The transporting mechanism can potentially be applied to miniaturize sample analysis system or " lab-on-chip" devices.
Advanced Ceramics Property and Performance Measurements
NASA Technical Reports Server (NTRS)
Jenkins, Michael; Salem, Jonathan; Helfinstine, John; Quinn, George; Gonczy, Stephen
2015-01-01
Mechanical and physical properties of ceramic bodies can be difficult to measure correctly unless the proper techniques are used. The Advanced Ceramics Committee of ASTM, C-28, has developed dozens of consensus test standards and practices to measure various properties of a ceramic monolith, composite, or coating. The standards give the what, how, how not, and why for measurement of many mechanical, physical, thermal, and performance properties. Using these standards will provide accurate, reliable, and complete data for rigorous comparisons with other test results from your test lab, or another. The C-28 Committee has involved academics, producers, and users of ceramics to write and continually update more than 45 standards since the committees inception in 1986. Included in this poster is a pictogram of the C-28 standards and information on how to obtain individual copies with full details or the complete collection of all of the standards in one volume.
An observational study of the effect of vibration on the caking of suspensions in oily vehicles.
Jain, Rohit; Bork, Olaf; Alawi, Fadil; Nanjan, Karthigeyan; Tucker, Ian G
2016-11-30
An oily suspension of penethamate (PNT) that was physically stable on storage, caked solidly during road/air transport. This paper reports on the caking behaviour of PNT oily suspension formulations exposed to vibrations in a lab-based test designed to simulate road/air transport. The lab-test was used to study the effects of container type (glass v PET) and formulation (oil, surfactant type and concentration) on the physical stability of suspension under vibration. Redispersibility of the sediment was lower at longer vibrations times and at higher intensity of vibration. Caking on vibration was strongly influenced by the type of container (caking in glass but not in PET) possibly due to tribo-charging of particles. Caking on vibration was dependent on the formulation: type and concentration of surfactant; type of oil. The physical stability of oily suspensions, and the effect of vibration are two areas which have been largely neglected in the pharmaceutical literature. This paper discusses some potential mechanisms for the observations but studies using fully characterised materials are required. Finally we conclude that static testing of physical stability of oily suspensions is not sufficient and that a vibrational stress test is required. Copyright © 2016 Elsevier B.V. All rights reserved.
Challenges in Characterizing Low-Temperature Regolith Properties
NASA Technical Reports Server (NTRS)
Swanger, Adam Michael; Mantovani, James G.
2014-01-01
The success or failure of in-situ resource utilization for planetary surface exploration--be it for scientific, colonization or commercialization purposes--relies heavily on the ability to design and implement systems which effectively process the associated regolith and exploit its benefits. In most cases this challenge necessarily includes the characterization of low-temperature (cryogenic) properties; as many celestial destinations of interest, such as the moon, Mars and asteroids, have little or no atmosphere to help sustain the consistently "high" surface temperatures seen on planets such as Earth, and therefore can experience permanent cryogenic temperatures or dramatic cyclical changes. Characterization of physical properties (such as specific heat, thermal and electrical conductivity, etc.) over the entire temperature profile is undoubtedly an important piece of the puzzle; however, the impact on mechanical properties due to the introduction of icy deposit must also be explored in order to devise effective and robust excavation technologies. Currently the Granular Mechanics and Regolith Operations Lab and the Cryogenics Test Lab at NASA Kennedy Space Center are developing technologies and experimental methods to address these challenges and aid in the characterization of physical and mechanical properties of regolith at cryogenic temperatures. This presentation will review the current state of knowledge concerning lunar regolith at low temperature including that of icy regolith.
Opto-mechanical lab-on-fibre seismic sensors detected the Norcia earthquake.
Pisco, Marco; Bruno, Francesco Antonio; Galluzzo, Danilo; Nardone, Lucia; Gruca, Grzegorz; Rijnveld, Niek; Bianco, Francesca; Cutolo, Antonello; Cusano, Andrea
2018-04-27
We have designed and developed lab-on-fibre seismic sensors containing a micro-opto-mechanical cavity on the fibre tip. The mechanical cavity is designed as a double cantilever suspended on the fibre end facet and connected to a proof mass to tune its response. Ground acceleration leads to displacement of the cavity length, which in turn can be remotely detected using an interferometric interrogation technique. After the sensors characterization, an experimental validation was conducted at the Italian National Institute of Geophysics and Volcanology (INGV), which is responsible for seismic surveillance over the Italian country. The fabricated sensors have been continuously used for long periods to demonstrate their effectiveness as seismic accelerometer sensors. During the tests, fibre optic seismic accelerometers clearly detected the seismic sequence that culminated in the severe Mw6.5 Norcia earthquake that struck central Italy on October 30, 2016. The seismic data provided by the optical sensors were analysed by specialists at the INGV. The wave traces were compared with state-of-the-art traditional sensors typically incorporated into the INGV seismic networks. The comparison verifies the high fidelity of the optical sensors in seismic wave detection, indicating their suitability for a novel class of seismic sensors to be employed in practical scenarios.
Modified Matching Ronchi Test to Visualize Lens Aberrations
ERIC Educational Resources Information Center
Hassani, Kh; Ziafi, H. Hooshmand
2011-01-01
We introduce a modification to the matching Ronchi test to visualize lens aberrations with simple and inexpensive equipment available in educational optics labs. This method can help instructors and students to observe and estimate lens aberrations in real time. It is also a semi-quantitative tool for primary tests in research labs. In this work…
Virtual Learning Environment for Interactive Engagement with Advanced Quantum Mechanics
NASA Astrophysics Data System (ADS)
Pedersen, Mads Kock; Skyum, Birk; Heck, Robert; Müller, Romain; Bason, Mark; Lieberoth, Andreas; Sherson, Jacob F.
2016-06-01
A virtual learning environment can engage university students in the learning process in ways that the traditional lectures and lab formats cannot. We present our virtual learning environment StudentResearcher, which incorporates simulations, multiple-choice quizzes, video lectures, and gamification into a learning path for quantum mechanics at the advanced university level. StudentResearcher is built upon the experiences gathered from workshops with the citizen science game Quantum Moves at the high-school and university level, where the games were used extensively to illustrate the basic concepts of quantum mechanics. The first test of this new virtual learning environment was a 2014 course in advanced quantum mechanics at Aarhus University with 47 enrolled students. We found increased learning for the students who were more active on the platform independent of their previous performances.
DOE Office of Scientific and Technical Information (OSTI.GOV)
none, none; Tuchman, Nancy
The U.S. Department of Energy awarded Loyola University Chicago and the Institute of Environmental Sustainability (IES) $486,000.00 for the proposal entitled “Chicago clean air, clean water project: Environmental monitoring for a healthy, sustainable urban future.” The project supported the purchase of analytical instruments for the development of an environmental analytical laboratory. The analytical laboratory is designed to support the testing of field water and soil samples for nutrients, industrial pollutants, heavy metals, and agricultural toxins, with special emphasis on testing Chicago regional soils and water affected by coal-based industry. Since the award was made in 2010, the IES has beenmore » launched (fall 2013), and the IES acquired a new state-of-the-art research and education facility on Loyola University Chicago’s Lakeshore campus. Two labs were included in the research and education facility. The second floor lab is the Ecology Laboratory where lab experiments and analyses are conducted on soil, plant, and water samples. The third floor lab is the Environmental Toxicology Lab where lab experiments on environmental toxins are conducted, as well as analytical tests conducted on water, soil, and plants. On the south end of the Environmental Toxicology Lab is the analytical instrumentation collection purchased from the present DOE grant, which is overseen by a full time Analytical Chemist (hired January 2016), who maintains the instruments, conducts analyses on samples, and helps to train faculty and undergraduate and graduate student researchers.« less
DETAIL VIEW OF TESTING EQUIPMENT, REMOTE MANIPULATOR SYSTEM LAB, ROOM ...
DETAIL VIEW OF TESTING EQUIPMENT, REMOTE MANIPULATOR SYSTEM LAB, ROOM NO. 1N4, FACING SOUTHEAST - Cape Canaveral Air Force Station, Launch Complex 39, Vehicle Assembly Building, VAB Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
Threshold-Switchable Particles (TSP) to Control Internal Hemorrhage
2012-12-01
the Liu lab (in collaboration with the Morrissey lab): Citrate gold nanoparticle synthesis (toward Task 3, Milestone 4) Gold nanoparticles with an...dimethylamino) propyl ]carbodiimide). Different pH conditions were used to test the conjugation efficiency between PAAc and cystamine. An excess amount of...Studies from the Stucky lab (in collaboration with the Morrissey lab): Silica Nanoparticle (SNP) synthesis (toward Task 3, Milestone 4) In our
Hyle, Emily P; Jani, Ilesh V; Lehe, Jonathan; Su, Amanda E; Wood, Robin; Quevedo, Jorge; Losina, Elena; Bassett, Ingrid V; Pei, Pamela P; Paltiel, A David; Resch, Stephen; Freedberg, Kenneth A; Peter, Trevor; Walensky, Rochelle P
2014-09-01
Point-of-care CD4 tests at HIV diagnosis could improve linkage to care in resource-limited settings. Our objective is to evaluate the clinical and economic impact of point-of-care CD4 tests compared to laboratory-based tests in Mozambique. We use a validated model of HIV testing, linkage, and treatment (CEPAC-International) to examine two strategies of immunological staging in Mozambique: (1) laboratory-based CD4 testing (LAB-CD4) and (2) point-of-care CD4 testing (POC-CD4). Model outcomes include 5-y survival, life expectancy, lifetime costs, and incremental cost-effectiveness ratios (ICERs). Input parameters include linkage to care (LAB-CD4, 34%; POC-CD4, 61%), probability of correctly detecting antiretroviral therapy (ART) eligibility (sensitivity: LAB-CD4, 100%; POC-CD4, 90%) or ART ineligibility (specificity: LAB-CD4, 100%; POC-CD4, 85%), and test cost (LAB-CD4, US$10; POC-CD4, US$24). In sensitivity analyses, we vary POC-CD4-specific parameters, as well as cohort and setting parameters to reflect a range of scenarios in sub-Saharan Africa. We consider ICERs less than three times the per capita gross domestic product in Mozambique (US$570) to be cost-effective, and ICERs less than one times the per capita gross domestic product in Mozambique to be very cost-effective. Projected 5-y survival in HIV-infected persons with LAB-CD4 is 60.9% (95% CI, 60.9%-61.0%), increasing to 65.0% (95% CI, 64.9%-65.1%) with POC-CD4. Discounted life expectancy and per person lifetime costs with LAB-CD4 are 9.6 y (95% CI, 9.6-9.6 y) and US$2,440 (95% CI, US$2,440-US$2,450) and increase with POC-CD4 to 10.3 y (95% CI, 10.3-10.3 y) and US$2,800 (95% CI, US$2,790-US$2,800); the ICER of POC-CD4 compared to LAB-CD4 is US$500/year of life saved (YLS) (95% CI, US$480-US$520/YLS). POC-CD4 improves clinical outcomes and remains near the very cost-effective threshold in sensitivity analyses, even if point-of-care CD4 tests have lower sensitivity/specificity and higher cost than published values. In other resource-limited settings with fewer opportunities to access care, POC-CD4 has a greater impact on clinical outcomes and remains cost-effective compared to LAB-CD4. Limitations of the analysis include the uncertainty around input parameters, which is examined in sensitivity analyses. The potential added benefits due to decreased transmission are excluded; their inclusion would likely further increase the value of POC-CD4 compared to LAB-CD4. POC-CD4 at the time of HIV diagnosis could improve survival and be cost-effective compared to LAB-CD4 in Mozambique, if it improves linkage to care. POC-CD4 could have the greatest impact on mortality in settings where resources for HIV testing and linkage are most limited. Please see later in the article for the Editors' Summary.
Allergen screening bioassays: recent developments in lab-on-a-chip and lab-on-a-disc systems.
Ho, Ho-pui; Lau, Pui-man; Kwok, Ho-chin; Wu, Shu-yuen; Gao, Minghui; Cheung, Anthony Ka-lun; Chen, Qiulan; Wang, Guanghui; Kwan, Yiu-wa; Wong, Chun-kwok; Kong, Siu-kai
2014-01-01
Allergies occur when a person's immune system mounts an abnormal response with or without IgE to a normally harmless substance called an allergen. The standard skin-prick test introduces suspected allergens into the skin with lancets in order to trigger allergic reactions. This test is annoying and sometimes life threatening. New tools such as lab-on-a-chip and lab-on-a-disc, which rely on microfabrication, are designed for allergy testing. These systems provide benefits such as short analysis times, enhanced sensitivity, simplified procedures, minimal consumption of sample and reagents and low cost. This article gives a summary of these systems. In particular, a cell-based assay detecting both the IgE- and non-IgE-type triggers through the study of degranulation in a centrifugal microfluidic system is highlighted.
The vacuum tribology model (VTM) of TriboLAB
NASA Astrophysics Data System (ADS)
Garmendia, I.; Landaberea, A.; Anglada, E.; Fernández-Sanz, R.; Santiago, R.; Herrada, F.; Encinas, J. M.
2003-09-01
TriboLAB is a tribology instrument that is planned for installation in the EuteF Flight Segment Platform, along with several other European scientific instruments. EuteF will be fixed onto an Express Pallet Adapter (ExPA), which provides standard structural, mechanical, electrical and communications interfaces to the Columbus External Payload Facility of the International Space Station (ISS). As a part of the model philosophy, a vacuum tribological model (VTM) has been developed to generate "on ground" tribological data of selected lubricants. The idea is to compare the results obtained "on ground" with those that will be produced in the space, in order to investigate the different behaviors of same tribological films and to be able to compare the performance of specific lubricants in Low Earth Orbit (LEO) conditions. The VTM is composed of six double experiment cells that perform respectively ball bearing (BB) experiments (with liquid and solid lubrication) and pin-on-disk (PoD) tests of solid lubricants. Thin films of alloyed MoS2 are being tested in the VTM under controlled vacuum conditions. In this work, the two sections of the VTM are described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calcaterra, J.R.; Johnson, W.S.; Neu, R.W.
1997-12-31
Several methodologies have been developed to predict the lives of titanium matrix composites (TMCs) subjected to thermomechanical fatigue (TMF). This paper reviews and compares five life prediction models developed at NASA-LaRC. Wright Laboratories, based on a dingle parameter, the fiber stress in the load-carrying, or 0{degree}, direction. The two other models, both developed at Wright Labs. are multi-parameter models. These can account for long-term damage, which is beyond the scope of the single-parameter models, but this benefit is offset by the additional complexity of the methodologies. Each of the methodologies was used to model data generated at NASA-LeRC. Wright Labs.more » and Georgia Tech for the SCS-6/Timetal 21-S material system. VISCOPLY, a micromechanical stress analysis code, was used to determine the constituent stress state for each test and was used for each model to maintain consistency. The predictive capabilities of the models are compared, and the ability of each model to accurately predict the responses of tests dominated by differing damage mechanisms is addressed.« less
Lab-Scale Stimulation Results on Surrogate Fused Silica Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlos Fernandez
Lab-scale stimulation work on non-porous fused silica (similar mechanical properties to igneous rock) was performed using pure water, pure CO2 and water/CO2 mixtures to compare back to back fracturing performance of these fluids with PNNL's StimuFrac.
Kariuki, Jacob K; Gona, Philimon; Leveille, Suzanne G; Stuart-Shor, Eileen M; Hayman, Laura L; Cromwell, Jerry
2018-06-01
The non-lab Framingham algorithm, which substitute body mass index for lipids in the laboratory based (lab-based) Framingham algorithm, has been validated among African Americans (AAs). However, its cost-effectiveness and economic tradeoffs have not been evaluated. This study examines the incremental cost-effectiveness ratio (ICER) of two cardiovascular disease (CVD) prevention programs guided by the non-lab versus lab-based Framingham algorithm. We simulated the World Health Organization CVD prevention guidelines on a cohort of 2690 AA participants in the Atherosclerosis Risk in Communities (ARIC) cohort. Costs were estimated using Medicare fee schedules (diagnostic tests, drugs & visits), Bureau of Labor Statistics (RN wages), and estimates for managing incident CVD events. Outcomes were assumed to be true positive cases detected at a data driven treatment threshold. Both algorithms had the best balance of sensitivity/specificity at the moderate risk threshold (>10% risk). Over 12years, 82% and 77% of 401 incident CVD events were accurately predicted via the non-lab and lab-based Framingham algorithms, respectively. There were 20 fewer false negative cases in the non-lab approach translating into over $900,000 in savings over 12years. The ICER was -$57,153 for every extra CVD event prevented when using the non-lab algorithm. The approach guided by the non-lab Framingham strategy dominated the lab-based approach with respect to both costs and predictive ability. Consequently, the non-lab Framingham algorithm could potentially provide a highly effective screening tool at lower cost to address the high burden of CVD especially among AA and in resource-constrained settings where lab tests are unavailable. Copyright © 2017 Elsevier Inc. All rights reserved.
My Brother’s Keeper National Lab Week
2016-03-02
Students in the My Brother’s Keeper program line the railings of an observation deck overlooking the Granular Mechanics and Regolith Operations Lab at NASA’s Kennedy Space Center in Florida. The spaceport is one of six NASA centers that participated in My Brother’s Keeper National Lab Week. The event is a nationwide effort to bring youth from underrepresented communities into federal labs and centers for hands-on activities, tours and inspirational speakers. Sixty students from the nearby cities of Orlando and Sanford visited Kennedy, where they toured the Vehicle Assembly Building, the Space Station Processing Facility and the center’s innovative Swamp Works Labs. The students also had a chance to meet and ask questions of a panel of subject matter experts from across Kennedy.
Off to the (Earthworm) Races: A Quick and Flexible Lab Experiment for Introductory Zoology Courses.
ERIC Educational Resources Information Center
Switzer, Paul V.; Fritz, Ann H.
2001-01-01
Presents a hands-on, investigative lab activity for use in an introductory zoology course. Tests the behavioral hypothesis that substrate texture affects earthworm locomotor ability. Provides background information on earthworm locomotion followed by details of the lab exercise. (NB)
LPT. Shield test facility (TAN645 and 646). Calibration lab shield ...
LPT. Shield test facility (TAN-645 and -646). Calibration lab shield door. Ralph M. Parsons 1229-17 ANP/GE-6-645-MS-1. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645-40-693-107369 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Sánchez-Martín, J.; Beltrán-Heredia, J.; Coco-Rivero, B.
2014-09-01
Quebracho colorado tannin extract was used as a coagulant raw material for water and wastewater treatment. The chemical synthesis follows a Mannich reaction mechanism and provides a fully working coagulant that can remove several pollutants from water. This paper addresses the optimization of such synthesis and confirms the feasibility of the coagulant by testing it in a preliminary screening for the elimination of dyes and detergents. The optimum combination of reagents was 6.81 g of diethanolamine (DEA) and 2.78 g of formaldehyde (F) per g of tannin extract. So obtained coagulant was succesfully tested on the removal of 9 dyes and 8 detergents.
2007-08-07
LCROSS flight hardware in clean room at Ames N-240. EEL personnel fabricating testing components with Jerry Wang of Ames, Engineering Evaluation labLCROSS flight hardware in clean room at Ames N-240. EEL personnel fabricating testing components with Jerry Wang of Ames, Engineering Evaluation lab
Thirty Stage Annular Centrifugal Contactor Thermal Profile Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
David H. Meikrantz; Troy G. Garn; Jack D. Law
2010-02-01
A thirty stage 5 cm annular centrifugal contactor cascade has been assembled and tested to obtain thermal profiles during both ambient and heated input conditions of operation. Thermocouples were installed on every stage as well as feed inputs and Real-time data was taken during experiments lasting from two to eight hours at total flow rates of 0.5 to 1.4 liters per minute. Ambient temperature profile results show that only a small amount of heat is generated by the mechanical energy of the contactors. Steady state temperature profiles mimic the ambient temperature of the lab but are higher toward the middlemore » of the cascade. Heated inlet solutions gave temperature profiles with smaller temperature gradients, more driven by the temperature of the inlet solutions than ambient lab temperature. Temperature effects of solution mixing, even at rotor speeds of 4000 rpm, were not measurable.« less
Phenemenological vs. biophysical models of thermal stress in aquatic eggs
NASA Astrophysics Data System (ADS)
Martin, B.
2016-12-01
Predicting species responses to climate change is a central challenge in ecology, with most efforts relying on lab derived phenomenological relationships between temperature and fitness metrics. We tested one of these models using the embryonic stage of a Chinook salmon population. We parameterized the model with laboratory data, applied it to predict survival in the field, and found that it significantly underestimated field-derived estimates of thermal mortality. We used a biophysical model based on mass-transfer theory to show that the discrepancy was due to the differences in water flow velocities between the lab and the field. This mechanistic approach provides testable predictions for how the thermal tolerance of embryos depends on egg size and flow velocity of the surrounding water. We found support for these predictions across more than 180 fish species, suggesting that flow and temperature mediated oxygen limitation is a general mechanism underlying the thermal tolerance of embryos.
Piccart, K; Vásquez, A; Piepers, S; De Vliegher, S; Olofsson, T C
2016-04-01
Despite the increasing knowledge of prevention and control strategies, bovine mastitis remains one of the most challenging diseases in the dairy industry. This study investigated the antimicrobial activity of 13 species of lactic acid bacteria (LAB), previously isolated from the honey crop of the honeybee, on several mastitis pathogens. The viable LAB were first reintroduced into a sterilized heather honey matrix. More than 20 different bovine mastitis isolates were tested against the mixture of the 13 LAB species in the honey medium using a dual-culture overlay assay. The mastitis isolates were identified through bacteriological culturing, followed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Additionally, the mastitis isolates were subjected to antimicrobial susceptibility testing through disk diffusion. Growth of all tested mastitis pathogens, including the ones displaying antimicrobial resistance to one or more antimicrobial compounds, were inhibited to some extent by the honey and LAB combination. The antibacterial effect of these LAB opens up new perspectives on alternative treatment and prevention of bovine mastitis. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Activity level in the lab: Overlap with shyness indicates it is more than pure motoric activity.
Frazier-Wood, Alexis C; Saudino, Kimberly J
2017-09-01
The observation that children's activity level (AL) differs between novel and familiar situations is well established. What influences individual differences in how AL is different across these situations is less well understood. Drawing on animal literature, which links rats' AL when 1st placed in a novel setting with novelty seeking phenotypes, and child temperament literature, which links AL, novelty response, and shyness, we hypothesized that shyness would be an important component of children's AL in a novel situation. We examined this using mechanically assessed AL from 2 situations (the home and the lab) and 2 measures of shyness (1 parent-rated and 1 observer-rated) on up to 313 twin pairs (145 monozygotic and 168 dizygotic), at 2 and 3 years of age. Biometric genetic models removed from lab AL the variance shared with home AL, representing what was different in AL when the child entered the lab compared to the home. We report that almost half (43%) of the genetic component of AL in the lab was independent of AL in the home, and this unique genetic component shared genetic covariance with shyness. Shyness influences AL in a novel situation such as the lab, indicating that mechanically assessed AL represents more than global motoric activity and provides information on a child's temperamental response to novelty. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Traditional Labs + New Questions = Improved Student Performance.
ERIC Educational Resources Information Center
Rezba, Richard J.; And Others
1992-01-01
Presents three typical lab activities involving the breathing rate of fish, the behavior of electromagnets, and tests for water hardness to demonstrate how labs can be modified to teach process skills. Discusses how basic concepts about experimentation are developed and ways of generating and improving science experiments. Includes a laboratory…
Marshall, Pamela A
2007-01-01
In our Fundamentals of Genetics lab, students perform a wide variety of labs to reinforce and extend the topics covered in lecture. I developed an active-learning lab to augment the lecture topic of mutagenesis. In this lab exercise, students determine if a compound they bring from home is a mutagen. Students are required to read extensive background material, perform research to find a potential mutagen to test, develop a hypothesis, and bring to the lab their own suspected mutagen. This lab uses a specially developed strain of Saccharomyces cerevisiae, D7, to determine if a compound is a mutagen. Mutagenesis of the D7 genome can lead to a scorable alteration in the phenotypes of this strain. Students outline and carry out a protocol for treatment of the yeast tester strain, utilizing the concept of dose/response and positive and negative controls. Students report on their results using a PowerPoint presentation to simulate giving a scientific presentation. The students' self-assessment of their knowledge indicated that, in all cases, the students felt that they knew more about the assay, mutagenesis, and the relationship between genotype and phenotype (P < 0.05) after completing the exercise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brindza, Paul; Lassiter, Steven; Sun, Eric
Jefferson Lab is constructing an 11 Gev/c electron spectrometer called the Super High Momentum Spectrometer (SHMS) as part of the 12 GeV JLAB upgrade for experimental Hall C. Three of the five superconducting(SC) SHMS magnets are under construction at SigmaPhi in Vannes France as a result of an international competition for design and fabrication. The three magnets Q2 and Q3 60 cm bore quadrupoles and the 60 cm warm bore dipole are complete or near complete and have many design features in common. All three magnets share a common superconductor, collaring system, cryostat design, cold to warm support, cryogenic interface,more » burnout resistant current leads, DC power supply, quench protection, instrumentation and controls. The three magnets are collared, installed in cryostats and welded up and in various stages of final testing. The Q2 quadrupole is due to ship from France to America in August arriving during this ASC conference and has passed all final hipot, leak and pressure tests. The dipole is in leak and pressure testing as of July 2016 while the Q3 quadrupole requires some outer vacuum vessel assembly. Delivery of the Q3 and Dipole magnets will follow the Q2 at about 1 month intervals. Lastly, factory testing have included hipot and electrical tests, magnetic tests at low field, mechanical alignments to center the coils, leak tests and ASME Code required pressure tests. Upon installation in Hall C at JLAB cold testing will commence.« less
Brindza, Paul; Lassiter, Steven; Sun, Eric; ...
2017-06-01
Jefferson Lab is constructing an 11 Gev/c electron spectrometer called the Super High Momentum Spectrometer (SHMS) as part of the 12 GeV JLAB upgrade for experimental Hall C. Three of the five superconducting(SC) SHMS magnets are under construction at SigmaPhi in Vannes France as a result of an international competition for design and fabrication. The three magnets Q2 and Q3 60 cm bore quadrupoles and the 60 cm warm bore dipole are complete or near complete and have many design features in common. All three magnets share a common superconductor, collaring system, cryostat design, cold to warm support, cryogenic interface,more » burnout resistant current leads, DC power supply, quench protection, instrumentation and controls. The three magnets are collared, installed in cryostats and welded up and in various stages of final testing. The Q2 quadrupole is due to ship from France to America in August arriving during this ASC conference and has passed all final hipot, leak and pressure tests. The dipole is in leak and pressure testing as of July 2016 while the Q3 quadrupole requires some outer vacuum vessel assembly. Delivery of the Q3 and Dipole magnets will follow the Q2 at about 1 month intervals. Lastly, factory testing have included hipot and electrical tests, magnetic tests at low field, mechanical alignments to center the coils, leak tests and ASME Code required pressure tests. Upon installation in Hall C at JLAB cold testing will commence.« less
NASA Astrophysics Data System (ADS)
Govind, Ajit; Chen, Jing Ming; Margolis, Hank; Ju, Weimin; Sonnentag, Oliver; Giasson, Marc-André
2009-04-01
SummaryA spatially explicit, process-based hydro-ecological model, BEPS-TerrainLab V2.0, was developed to improve the representation of ecophysiological, hydro-ecological and biogeochemical processes of boreal ecosystems in a tightly coupled manner. Several processes unique to boreal ecosystems were implemented including the sub-surface lateral water fluxes, stratification of vegetation into distinct layers for explicit ecophysiological representation, inclusion of novel spatial upscaling strategies and biogeochemical processes. To account for preferential water fluxes common in humid boreal ecosystems, a novel scheme was introduced based on laboratory analyses. Leaf-scale ecophysiological processes were upscaled to canopy-scale by explicitly considering leaf physiological conditions as affected by light and water stress. The modified model was tested with 2 years of continuous measurements taken at the Eastern Old Black Spruce Site of the Fluxnet-Canada Research Network located in a humid boreal watershed in eastern Canada. Comparison of the simulated and measured ET, water-table depth (WTD), volumetric soil water content (VSWC) and gross primary productivity (GPP) revealed that BEPS-TerrainLab V2.0 simulates hydro-ecological processes with reasonable accuracy. The model was able to explain 83% of the ET, 92% of the GPP variability and 72% of the WTD dynamics. The model suggests that in humid ecosystems such as eastern North American boreal watersheds, topographically driven sub-surface baseflow is the main mechanism of soil water partitioning which significantly affects the local-scale hydrological conditions.
Design of a Low-Cost Air Levitation System for Teaching Control Engineering.
Chacon, Jesus; Saenz, Jacobo; Torre, Luis de la; Diaz, Jose Manuel; Esquembre, Francisco
2017-10-12
Air levitation is the process by which an object is lifted without mechanical support in a stable position, by providing an upward force that counteracts the gravitational force exerted on the object. This work presents a low-cost lab implementation of an air levitation system, based on open solutions. The rapid dynamics makes it especially suitable for a control remote lab. Due to the system's nature, the design can be optimized and, with some precision trade-off, kept affordable both in cost and construction effort. It was designed to be easily adopted to be used as both a remote lab and as a hands-on lab.
Cookbook Procedures in MBL Physics Exercises.
ERIC Educational Resources Information Center
Royuk, Brent; Brooks, David W.
2003-01-01
Presents results of a controlled experiment comparing the conceptual mechanics learning gains as measured by the Force Concept Inventory (FCI) between two laboratory groups. One group completed cookbook labs while the other completed Interactive-Engagement (IE) labs in RealTime Physics. Suggests that laboratory activities should engage students in…
ERIC Educational Resources Information Center
Dowling, John, Jr.
1972-01-01
Discusses the use of a set of computer programs (FORTRAN IV) in an introductory mechanics course for science majors. One laboratory activity is described for determining the coefficient of restitution of a glider on an air track. A student evaluation for the lab is included in the appendix. (Author/TS)
Evaluation of Inter-Mountain Labs infrasound sensors : July 2007.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Darren M.
2007-10-01
Sandia National Laboratories has tested and evaluated three Inter Mountain Labs infrasound sensors. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Inter Mountain Labs (IML) infrasound sensor model SS. The results of this evaluation were only comparedmore » to relevant noise models; due to a lack of manufactures documentation notes on the sensors under test prior to testing. The tests selected for this system were chosen to demonstrate different performance aspects of the components under test.« less
Bellandi, T; Albolino, S; Tartaglia, R; Filipponi, F
2010-01-01
In February 2007, three organs from an human immunodeficiency virus (HIV)-positive donor were transplanted at two hospitals in the Tuscany Regional Health Care Service, owing to a chain of errors during the donation process. The heart-beating donor was a 41-year-old woman who died as a result of head trauma. The patient's history did not highlight any risky behavior. The available data on previous hospital admissions reported a negative result on HIV testing. During the donation process, the result of the lab test performed for evaluation of organ suitability was mistakenly transcribed from positive to negative. This wrong negative result was then included in the donation record without any cross-check. Therefore, the Regional Transplant Center allocated the liver and both kidneys. The patient also donated tissues, and a second laboratory conducted an evaluation of suitability for the tissue banks. During this process, only 5 days after the successful transplantation procedures, the positive HIV result was fed back to the Regional Transplant Center and the previous error discovered. Transplanted patients were immediately assessed and then treated with antiretroviral medications. A national commission soon performed a systems analysis of the adverse event. Besides the active error committed during the manual transcription for the HIV lab test result, the commission also identified technological factors, such as the lack of integration between the lab machine, the laboratory information system (LIS), and the donor record, as well as organizational factors, such as the distribution to two different labs of the suitability evaluation for organs and tissues. Recommendations included: automatic transmission of lab test results from the lab machine to the LIS and to the donor record, centralization of lab tests for suitability evaluation of organs and tissues, a training program to develop a proactive quality and safety culture in the regional network of donation and transplantations. Copyright 2010. Published by Elsevier Inc.
Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-Ichiro
2009-06-01
A validation study of an in vitro skin irritation testing method using a reconstructed human skin model has been conducted by the European Centre for the Validation of Alternative Methods (ECVAM), and a protocol using EpiSkin (SkinEthic, France) has been approved. The structural and performance criteria of skin models for testing are defined in the ECVAM Performance Standards announced along with the approval. We have performed several evaluations of the new reconstructed human epidermal model LabCyte EPI-MODEL, and confirmed that it is applicable to skin irritation testing as defined in the ECVAM Performance Standards. We selected 19 materials (nine irritants and ten non-irritants) available in Japan as test chemicals among the 20 reference chemicals described in the ECVAM Performance Standard. A test chemical was applied to the surface of the LabCyte EPI-MODEL for 15 min, after which it was completely removed and the model then post-incubated for 42 hr. Cell v iability was measured by MTT assay and skin irritancy of the test chemical evaluated. In addition, interleukin-1 alpha (IL-1alpha) concentration in the culture supernatant after post-incubation was measured to provide a complementary evaluation of skin irritation. Evaluation of the 19 test chemicals resulted in 79% accuracy, 78% sensitivity and 80% specificity, confirming that the in vitro skin irritancy of the LabCyte EPI-MODEL correlates highly with in vivo skin irritation. These results suggest that LabCyte EPI-MODEL is applicable to the skin irritation testing protocol set out in the ECVAM Performance Standards.
Bulgasem, Bulgasem Y.; Lani, Mohd Nizam; Wan Yusoff, Wan Mohtar; Fnaish, Sumaya G.
2016-01-01
The role of lactic acid bacteria (LAB) in honey as antifungal activity has received little attention and their mechanism of inhibitory of fungi is not fully understood. In this study, LAB were isolated from honey samples from Malaysia, Libya, Saudi Arabia, and Yemen. Twenty-five isolates were confirmed LAB by catalase test and Gram staining, and were screened for antifungal activity. Four LAB showed inhibitory activity against Candida spp. using the dual agar overlay method. And they were identified as Lactobacillus plantarum HS isolated from Al-Seder honey, Lactobacillus curvatus HH isolated from Al-Hanon honey, Pediococcus acidilactici HC isolated from Tualang honey and Pediococcus pentosaceus HM isolated from Al-Maray honey by the 16S rDNA sequence. The growth of Candida glabrata ATCC 2001 was strongly inhibited (>15.0 mm) and (10~15 mm) by the isolates of L. curvatus HH and P. pentosaceus HM, respectively. The antifungal activity of the crude supernatant (cell free supernatant, CFS) was evaluated using well diffusion method. The CFS showed high antifungal activity against Candida spp. especially The CFS of L. curvatus HH was significantly (p < 0.05) inhibited growth of C. glabrata ATCC 2001, C. parapsilosis ATCC 2201, and C. tropicalis ATCC 750 with inhibitory zone 22.0, 15.6, and 14.7 mm, respectively. While CFS of P. pentosaceus HM was significantly (p < 0.05) effective against C. krusei, C. glabrata, and C. albicans with inhibition zone 17.2, 16.0, and 13.3 mm, respectively. The results indicated that LAB isolated from honey produced compounds which can be used to inhibit the growth of the pathogenic Candida species. PMID:28154488
Bulgasem, Bulgasem Y; Lani, Mohd Nizam; Hassan, Zaiton; Wan Yusoff, Wan Mohtar; Fnaish, Sumaya G
2016-12-01
The role of lactic acid bacteria (LAB) in honey as antifungal activity has received little attention and their mechanism of inhibitory of fungi is not fully understood. In this study, LAB were isolated from honey samples from Malaysia, Libya, Saudi Arabia, and Yemen. Twenty-five isolates were confirmed LAB by catalase test and Gram staining, and were screened for antifungal activity. Four LAB showed inhibitory activity against Candida spp. using the dual agar overlay method. And they were identified as Lactobacillus plantarum HS isolated from Al-Seder honey, Lactobacillus curvatus HH isolated from Al-Hanon honey, Pediococcus acidilactici HC isolated from Tualang honey and Pediococcus pentosaceus HM isolated from Al-Maray honey by the 16S rDNA sequence. The growth of Candida glabrata ATCC 2001 was strongly inhibited (>15.0 mm) and (10~15 mm) by the isolates of L. curvatus HH and P. pentosaceus HM, respectively. The antifungal activity of the crude supernatant (cell free supernatant, CFS) was evaluated using well diffusion method. The CFS showed high antifungal activity against Candida spp. especially The CFS of L. curvatus HH was significantly ( p < 0.05) inhibited growth of C. glabrata ATCC 2001, C. parapsilosis ATCC 2201, and C. tropicalis ATCC 750 with inhibitory zone 22.0, 15.6, and 14.7 mm, respectively. While CFS of P. pentosaceus HM was significantly ( p < 0.05) effective against C. krusei , C. glabrata , and C. albicans with inhibition zone 17.2, 16.0, and 13.3 mm, respectively. The results indicated that LAB isolated from honey produced compounds which can be used to inhibit the growth of the pathogenic Candida species.
A laser optical torquemeter for measuring the mechanical power furnished by a chirale turbine
NASA Astrophysics Data System (ADS)
Bonfanti, Marco; La Rosa, Guido; Lo Savio, Fabio
2005-02-01
The design of the present laser optical torquemeter arose from the need to measure the mechanical power furnished by a prototype of chirale turbine, which exploits the lift force produced in the rotor, due to the "Magnus effect." The particular optical reading system allows the device to determine both the torque and the mechanical power. The torque value is obtained through the reading of the torsional angle. From this value, together with that of the transmission shaft angular speed measured by the same torquemeter, the mechanical power of the turbine is calculated. The optical system output signals are acquired, processed and elaborated by a virtual logic circuit, simulated by means of a suitable home-made software in LabVIEW environment. The torquemeter has been tested operating with the prototype of turbine in a wind tunnel.
Intercomparison of Lab-Based Soil Water Extraction Methods for Stable Water Isotope Analysis
NASA Astrophysics Data System (ADS)
Pratt, D.; Orlowski, N.; McDonnell, J.
2016-12-01
The effect of pore water extraction technique on resultant isotopic signature is poorly understood. Here we present results of an intercomparison of five common lab-based soil water extraction techniques: high pressure mechanical squeezing, centrifugation, direct vapor equilibration, microwave extraction, and cryogenic extraction. We applied five extraction methods to two physicochemically different standard soil types (silty sand and clayey loam) that were oven-dried and rewetted with water of known isotopic composition at three different gravimetric water contents (8, 20, and 30%). We tested the null hypothisis that all extraction techniques would provide the same isotopic result independent from soil type and water content. Our results showed that the extraction technique had a significant effect on the soil water isotopic composition. Each method exhibited deviations from spiked reference water, with soil type and water content showing a secondary effect. Cryogenic extraction showed the largest deviations from the reference water, whereas mechanical squeezing and centrifugation provided the closest match to the reference water for both soil types. We also compared results for each extraction technique that produced liquid water on both an OA-ICOS and IRMS; differences between them were negligible.
NASA Astrophysics Data System (ADS)
Arneson, Pam
The Role Biomedical Science Laboratories Can Play In Improving Science Knowledge and Promoting First-Year Nursing Academic Success The need for additional nursing and health care professionals is expected to increase dramatically over the next 20 years. With this in mind, students must have strong biomedical science knowledge to be competent in their field. Some studies have shown that participation in bioscience laboratories can enhance science knowledge. If this is true, an analysis of the role bioscience labs have in first-year nursing academic success is apposite. In response, this study sought to determine whether concurrent enrollment in anatomy and microbiology lecture and lab courses improved final lecture course grades. The investigation was expanded to include a comparison of first-year nursing GPA and prerequisite bioscience concurrent lecture/lab enrollment. Additionally, research has indicated that learning is affected by student perception of the course, instructor, content, and environment. To gain an insight regarding students' perspectives of laboratory courses, almost 100 students completed a 20-statement perception survey to understand how lab participation affects learning. Data analyses involved comparing anatomy and microbiology final lecture course grades between students who concurrently enrolled in the lecture and lab courses and students who completed the lecture course alone. Independent t test analyses revealed that there was no significant difference between the groups for anatomy, t(285) = .11, p = .912, but for microbiology, the lab course provided a significant educational benefit, t(256) = 4.47, p = .000. However, when concurrent prerequisite bioscience lecture/lab enrollment was compared to non-concurrent enrollment for first-year nursing GPA using independent t test analyses, no significant difference was found for South Dakota State University, t(37) = -1.57, p = .125, or for the University of South Dakota, t(38) = -0.46, p = .651. Student perception survey examination included computation of means and standard deviations for statements related to the educational importance of lab courses, the value of lab experimentation, and the usefulness of concurrent lecture/lab enrollment. Independent t test analyses sought to determine differences within the courses of anatomy lab and microbiology lab as well as differences between the instructors involved. Results suggested that student perceptions may be dependent on the course, the instructor, and possibly the content.
Synchronized Pair Configuration in Virtualization-Based Lab for Learning Computer Networks
ERIC Educational Resources Information Center
Kongcharoen, Chaknarin; Hwang, Wu-Yuin; Ghinea, Gheorghita
2017-01-01
More studies are concentrating on using virtualization-based labs to facilitate computer or network learning concepts. Some benefits are lower hardware costs and greater flexibility in reconfiguring computer and network environments. However, few studies have investigated effective mechanisms for using virtualization fully for collaboration.…
Crazy Engineering Starshade and Coronagraph
2016-04-26
Episode 7 of Crazy Engineering series. Host Mike Meacham, Mechanical Engineer at JPL, learns about the two technologies NASA is investing in to image exoplanets: the Starshade and the Coronagraph. Mike interviews Nick Siegler, Program Chief Technologist, NASA Exoplanet Program in the Starshade lab and the High Contrast Imaging Testbed lab.
NASA Astrophysics Data System (ADS)
Broughton, Rachel; Gomez, Michael; Zolfaghari, Ali; Morris, Lewis
2016-10-01
A self-aligning Gaussian telescope has been designed to compensate for the effect of movement in the ITER vacuum vessel on the transmission line. The purpose of the setup is to couple microwaves into and out of the vessel across the vacuum windows while allowing for both slow movements of the vessel, due to thermal growth, and rapid movements, due to vibrations and disruptions. Additionally, a test stand has been designed specifically to hold this telescope in order to imitate these movements. Consequently, this will allow for the assessment of the efficacy in applying the self-aligning Gaussian telescope approach. The motions of the test stand, as well as the stress on the telescope mechanism, have been virtually simulated using ANSYS workbench. A prototype of this test stand and self-aligning telescope will be built using a combination of custom machined parts and ordered parts. The completed mechanism will be tested at the lab in four different ways: slow single- and multi-direction movements, rapid multi-direction movement, functional laser alignment and self-aligning tests, and natural frequency tests. Once the prototype successfully passes all requirements, it will be tested with microwaves in the LFSR transmission line test stand at General Atomics. This work is supported by US DOE Contract No. DE-AC02-09CH11466.
Stress Physiology of Lactic Acid Bacteria
Papadimitriou, Konstantinos; Alegría, Ángel; Bron, Peter A.; de Angelis, Maria; Gobbetti, Marco; Kleerebezem, Michiel; Lemos, José A.; Linares, Daniel M.; Ross, Paul; Stanton, Catherine; Turroni, Francesca; van Sinderen, Douwe; Varmanen, Pekka; Ventura, Marco; Zúñiga, Manuel; Tsakalidou, Effie
2016-01-01
SUMMARY Lactic acid bacteria (LAB) are important starter, commensal, or pathogenic microorganisms. The stress physiology of LAB has been studied in depth for over 2 decades, fueled mostly by the technological implications of LAB robustness in the food industry. Survival of probiotic LAB in the host and the potential relatedness of LAB virulence to their stress resilience have intensified interest in the field. Thus, a wealth of information concerning stress responses exists today for strains as diverse as starter (e.g., Lactococcus lactis), probiotic (e.g., several Lactobacillus spp.), and pathogenic (e.g., Enterococcus and Streptococcus spp.) LAB. Here we present the state of the art for LAB stress behavior. We describe the multitude of stresses that LAB are confronted with, and we present the experimental context used to study the stress responses of LAB, focusing on adaptation, habituation, and cross-protection as well as on self-induced multistress resistance in stationary phase, biofilms, and dormancy. We also consider stress responses at the population and single-cell levels. Subsequently, we concentrate on the stress defense mechanisms that have been reported to date, grouping them according to their direct participation in preserving cell energy, defending macromolecules, and protecting the cell envelope. Stress-induced responses of probiotic LAB and commensal/pathogenic LAB are highlighted separately due to the complexity of the peculiar multistress conditions to which these bacteria are subjected in their hosts. Induction of prophages under environmental stresses is then discussed. Finally, we present systems-based strategies to characterize the “stressome” of LAB and to engineer new food-related and probiotic LAB with improved stress tolerance. PMID:27466284
Park, Mi Ri; Kim, Younghoon; Lee, Myung-Ki
2015-01-01
The present study was conducted to screen candidate probiotic strains for anti-inflammatory activity. Initially, a nitric oxide (NO) assay was used to test selected candidate probiotic strains for anti-inflammatory activity in cultures of the murine macrophage cell line, RAW 264.7. Then, the in vitro probiotic properties of the strains, including bile tolerance, acid resistance, and growth in skim milk media, were investigated. We also performed an in vitro hydrophobicity test and an intestinal adhesion assay using Caenorhabditis elegans as a surrogate in vivo model. From our screening, we obtained 4 probiotic candidate lactic acid bacteria (LAB) strains based on their anti-inflammatory activity in lipopolysaccharide (LPS)-stimulated RAW 264.7 cell cultures and the results of the in vitro and in vivo probiotic property assessments. Molecular characterization using 16S rDNA sequencing analysis identified the 4 LAB strains as Lactobacillus plantarum. The selected L. plantarum strains (CAU1054, CAU1055, CAU1064, and CAU1106) were found to possess desirable in vitro and in vivo probiotic properties, and these strains are good candidates for further investigations in animal models and human clinical studies to elucidate the mechanisms underlying their anti-inflammatory activities. PMID:26761805
Baldassarri, Delia
2015-09-01
Repeated interaction and social networks are commonly considered viable solutions to collective action problems. This article identifies and systematically measures four general mechanisms--that is, generalized altruism, group solidarity, reciprocity, and the threat of sanctioning--and tests which of them brings about cooperation in the context of Ugandan producer organizations. Using an innovative methodological framework that combines "lab-in-the-field" experiments with survey interviews and complete social networks data, the article goes beyond the assessment of a relationship between social networks and collective outcomes to study the mechanisms that favor cooperative behavior. The article first establishes a positive relationship between position in the network structure and propensity to cooperate in the producer organization and then uses farmers' behavior in dictator and public goods games to test different mechanisms that may account for such a relationship. Results show that cooperation is induced by patterns of reciprocity that emerge through repeated interaction rather than other-regarding preferences like altruism or group solidarity.
Student construction of small molecule models using Spartan Model to explore polarity
NASA Astrophysics Data System (ADS)
Dale, Glenn Lamar
2006-12-01
This study compared the attitudes and the gains of knowledge concerning Lewis structures and polarity of molecules. The students performed a lab exercise in which they drew Lewis structures, constructed models of the molecules, determined the geometry of the molecules, and determined the polarity of the molecules. The control group students constructed models using physical ball-and-stick models. The treatment group students used Spartan Model to construct models. Students from a university and a community college participated in this study. Four lab classes at each school made up the treatment group. Five lab classes at the university and three lab classes at the community college made up the control group. The treatment group classes were selected based on available computer resources. All students in the study were given the Lab Pre Test, Lab Post Test, and the Lecture Post Test to assess the student's ability to answer questions pertaining to Lewis structures and polarity of molecules. An Attitudinal Survey assessed the attitudes of the students who participated in the study. Student interviews were performed to assess the student's attitudes towards the lab exercise. The interviews investigated attitudes about the modeling exercise, Lewis structures, and polarity of molecules. There were no significant differences in the performance of the treatment group when compared to the control group on the performance assessment instruments at the university or the community college. The treatment group students at the university had a more positive attitude about the lab activity. They believed that the lab activity helped them better understand the concepts of Lewis structure and molecular polarity. At the community college, the control group students had a more positive attitude about the lab activity. The students involved in the study believed that the lab activity helped them to understand the concepts of molecular geometry and polarity. The interviews of the treatment group students indicated that they strongly believed that the lab activity helped them better understand the concept of Lewis structures and of molecular polarity. As reflected in the interviews of the treatment group and the control group, the lab activity did not help the students be able to look at a Lewis structure and build a mental image of the molecule. The students believed the electrostatic potential plots generated by Spartan Model were very insightful into the concept of polarity. It gave them a visual representation of a difficult topic.
KSC Electrostatic Discharge (ESD) Issues
NASA Technical Reports Server (NTRS)
Buhler, Charles
2008-01-01
Discussion of key electrostatic issues that have arisen during the past few years at KSC that the Electrostatics Laboratory has studied. The lab has studied in depth the Space Shuttle's Thermal Control System Blankets, the International Space Station Thermal Blanket, the Pan/Tilt Camera Blankets, the Kapton Purge Barrier Curtain, the Aclar Purge Barrier Curtain, the Thrust Vector Controller Blankets, the Tyvek Reaction Control System covers, the AID-PAK and FLU-9 pyro inflatable devices, the Velostat Solid Rocket Booster mats, and the SCAPE suits. In many cases these materials are insulating meaning that they might be a source of unsafe levels of electrostatic discharge (ESD). For each, the lab provided in-depth testing of each material within its current configuration to ensure that it does not cause an ESD concern that may violate the safety of the astronauts, the workers and equipment for NASA. For example the lab provides unique solutions and testing such as Spark Incendivity Testing that checks whether a material is capable of generating a spark strong enough to ignite a flammable gas. The lab makes recommendations to changes in specifications, procedures, and material if necessary. The lab also consults with a variety of non-safety related ESD issues for the agency.
Virtual Lab to Develop Achievement in Electronic Circuits for Hearing-Impaired Students
ERIC Educational Resources Information Center
Baladoh, S. M.; Elgamal, A. F.; Abas, H. A.
2017-01-01
This paper aims to report and discuss the use of a virtual lab for developing achievement in electronic circuits for hearing-impaired students. Results from a number of studies have proved that the virtual lab allowed students to build and test a wide variety of electronic circuits. The present study was implemented to investigate the…
Visualization of lunar excavation test in NASA Glenn's GRUVE Lab
1969-12-31
Calvin Robinson of NASA Glenn's GVIS Team demonstrates a visualization of an excavation test conducted at NASA Glenn Research Center's SLOPE Lab ( https://rt.grc.nasa.gov/main/rlc/simu... ) . The visualization shows the flow of a lunar soil simulant as it flows in and past a proposed excavation bucket.
SOUTH WING, MTR661. INTERIOR DETAIL INSIDE LAB ROOM 131. CAMERA ...
SOUTH WING, MTR-661. INTERIOR DETAIL INSIDE LAB ROOM 131. CAMERA FACING NORTHEAST. NOTE CONCRETE BLOCK WALLS. SAFETY SHOWER AND EYE WASHER AT REAR WALL. INL NEGATIVE NO. HD46-7-2. Mike Crane, Photographer, 2/2005. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Plasma Physics Lab and the Tokamak Fusion Test Reactor, 1989
None
2018-01-16
From the Princeton University Archives: Promotional video about the Plasma Physics Lab and the new Tokamak Fusion Test Reactor (TFTR), with footage of the interior, machines, and scientists at work. This film is discussed in the audiovisual blog of the Seeley G. Mudd Manuscript Library, which holds the archives of Princeton University.
A HUPO test sample study reveals common problems in mass spectrometry-based proteomics
Bell, Alexander W.; Deutsch, Eric W.; Au, Catherine E.; Kearney, Robert E.; Beavis, Ron; Sechi, Salvatore; Nilsson, Tommy; Bergeron, John J.M.
2009-01-01
We carried out a test sample study to try to identify errors leading to irreproducibility, including incompleteness of peptide sampling, in LC-MS-based proteomics. We distributed a test sample consisting of an equimolar mix of 20 highly purified recombinant human proteins, to 27 laboratories for identification. Each protein contained one or more unique tryptic peptides of 1250 Da to also test for ion selection and sampling in the mass spectrometer. Of the 27 labs, initially only 7 labs reported all 20 proteins correctly, and only 1 lab reported all the tryptic peptides of 1250 Da. Nevertheless, a subsequent centralized analysis of the raw data revealed that all 20 proteins and most of the 1250 Da peptides had in fact been detected by all 27 labs. The centralized analysis allowed us to determine sources of problems encountered in the study, which include missed identifications (false negatives), environmental contamination, database matching, and curation of protein identifications. Improved search engines and databases are likely to increase the fidelity of mass spectrometry-based proteomics. PMID:19448641
Design of a Low-Cost Air Levitation System for Teaching Control Engineering
Chacon, Jesus; Saenz, Jacobo; de la Torre, Luis; Diaz, Jose Manuel; Esquembre, Francisco
2017-01-01
Air levitation is the process by which an object is lifted without mechanical support in a stable position, by providing an upward force that counteracts the gravitational force exerted on the object. This work presents a low-cost lab implementation of an air levitation system, based on open solutions. The rapid dynamics makes it especially suitable for a control remote lab. Due to the system’s nature, the design can be optimized and, with some precision trade-off, kept affordable both in cost and construction effort. It was designed to be easily adopted to be used as both a remote lab and as a hands-on lab. PMID:29023381
Pyro shock simulation: Experience with the MIPS simulator
NASA Technical Reports Server (NTRS)
Dwyer, Thomas J.; Moul, David S.
1988-01-01
The Mechanical Impulse Pyro Shock (MIPS) Simulator at GE Astro Space Division is one version of a design that is in limited use throughout the aerospace industry, and is typically used for component shock testing at levels up to 10,000 response g's. Modifications to the force imput, table and component boundary conditions have allowed a range of test conditions to be achieved. Twelve different designs of components with weights up to 23 Kg are in the process or have completed qualification testing in the Dynamic Simulation Lab at GE in Valley Forge, Pa. A summary of the experience gained through the use of this simulator is presented as well as examples of shock experiments that can be readily simulated at the GE Astro MIPS facility.
Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS.
Thomae, R; Conradie, J; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V
2016-02-01
At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.
Sujansky, Walter; Wilson, Tom
2015-04-01
This report describes a grant-funded project to explore the use of DIRECT secure messaging for the electronic delivery of laboratory test results to outpatient physicians and electronic health record systems. The project seeks to leverage the inherent attributes of DIRECT secure messaging and electronic provider directories to overcome certain barriers to the delivery of lab test results in the outpatient setting. The described system enables laboratories that generate test results as HL7 messages to deliver these results as structured or unstructured documents attached to DIRECT secure messages. The system automatically analyzes generated HL7 messages and consults an electronic provider directory to determine the appropriate DIRECT address and delivery format for each indicated recipient. The system also enables lab results delivered to providers as structured attachments to be consumed by HL7 interface engines and incorporated into electronic health record systems. Lab results delivered as unstructured attachments may be printed or incorporated into patient records as PDF files. The system receives and logs acknowledgement messages to document the status of each transmitted lab result, and a graphical interface allows searching and review of this logged information. The described system is a fully implemented prototype that has been tested in a laboratory setting. Although this approach is promising, further work is required to pilot test the system in production settings with clinical laboratories and outpatient provider organizations. Copyright © 2015 Elsevier Inc. All rights reserved.
2017-12-08
Inside the Prototype Development Laboratory at NASA's Kennedy Space Center in Florida, workers in the lab hold a banner marking the successful delivery of a liquid oxygen test tank called Tardis. Engineers and technicians worked together to develop the tank to build it at the lab to support cryogenic testing at Johnson Space Center's White Sands Test Facility in Las Cruces, New Mexico. The 12-foot-tall, 3,810-pound aluminum tank will be shipped to White Sands for testing.
Ciandrini, E; Campana, R; Baffone, W
2017-06-01
This research investigates the ability of live and heat-killed (HK) Lactic Acid Bacteria (LAB) to interfere with Streptococcus mutans ATCC 25175 and Streptococcus oralis ATCC 9811 during biofilm formation. Eight Lactobacillus spp. and two oral colonizers, pathogenic Streptococcus mutans and resident Streptococcus oralis, were characterized for their aggregation abilities, cell surface properties and biofilm formation ability on titanium surface. Then, the interference activity of selected live and HK Lactobacillus spp. during S. mutans and S. oralis biofilm development were performed. The cell-free culture supernatants (CFCS) anti-biofilm activity was also determined. LAB possess good abilities of auto-aggregation (from 14.19 to 28.97%) and of co-aggregation with S. oralis. The cell-surfaces characteristics were most pronounced in S. mutans and S. oralis, while the highest affinities to xylene and chloroform were observed in Lactobacillus rhamnosus ATCC 53103 (56.37%) and Lactobacillus paracasei B21060 (43.83%). S. mutans and S. oralis developed a biofilm on titanium surface, while LAB showed a limited or no ability to create biofilm. Live and HK L. rhamnosus ATCC 53103 and L. paracasei B21060 inhibited streptococci biofilm formation by competition and displacement mechanisms with no substantial differences. The CFCSs of both LAB strains, particularly the undiluted one of L. paracasei B21060, decreased S. mutans and S. oralis biofilm formation. This study evidenced the association of LAB aggregation abilities and cell-surface properties with the LAB-mediated inhibition of S. mutans and S. oralis biofilm formation. Lactobacilli showed different mechanisms of action and peculiar strain-specific characteristics, maintained also in the heat-killed LAB. Copyright © 2017 Elsevier Ltd. All rights reserved.
Physics for the Technologies. Supplementary Units.
ERIC Educational Resources Information Center
Brown, Tim; And Others
These supplemental units contain four laboratory exercises that can be used to enhance the labs in "Physics for the Technologies." The four units (one mechanical, two thermal, and one electrical) are designed to enhance labs in presenting specific concepts. Each unit can be used as an example of how the concepts behind the theory apply…
Femtosecond laser direct-write of optofluidics in polymer-coated optical fiber
NASA Astrophysics Data System (ADS)
Joseph, Kevin A. J.; Haque, Moez; Ho, Stephen; Aitchison, J. Stewart; Herman, Peter R.
2017-03-01
Multifunctional lab in fiber technology seeks to translate the accomplishments of optofluidic, lab on chip devices into silica fibers. a robust, flexible, and ubiquitous optical communication platform that can underpin the `Internet of Things' with distributed sensors, or enable lab on chip functions deep inside our bodies. Femtosecond lasers have driven significant advances in three-dimensional processing, enabling optical circuits, microfluidics, and micro-mechanical structures to be formed around the core of the fiber. However, such processing typically requires the stripping and recoating of the polymer buffer or jacket, increasing processing time and mechanically weakening the device. This paper reports on a comprehensive assessment of laser damage in urethane-acrylate-coated fiber. The results show a sufficient processing window is available for femtosecond laser processing of the fiber without damaging the polymer jacket. The fiber core, cladding, and buffer could be simultaneously processed without removal of the buffer jacket. Three-dimensional lab in fiber devices were successfully fabricated by distortion-free immersionlens focusing, presenting fiber-cladding optical circuits and progress towards chemically-etched channels, microfluidic cavities, and MEMS structure inside buffer-coated fiber.
Ge, Shenguang; Zhang, Yan; Yan, Mei; Huang, Jiadong; Yu, Jinghua
2017-01-01
A simple, low-cost, and sensitive electrochemical lab-on-paper assay is developed based on a novel gold nanoparticle modified porous paper working electrode for use in point-of-care testing (POCT). Electrochemical methods are introduced for lab-on-paper based on screen-printed paper electrodes. To further improve specificity, performance, and sensitivity for point-of-care testing, a novel porous Au-paper working electrode (Au-PWE) is designed for lab-on-paper using growth of an interconnected Au nanoparticle (NP) layer on the surface of cellulose fibers in order to enhance the conductivity of the paper sample zone and immobilize the primary antibodies (Ab1). With a sandwich-type immunoassay format, Pd-Au bimetallic nanoparticles possessing peroxidase-like activity are used as a matrix to immobilize secondary antibodies (Ab2) for rapid detection of targets. This lab-on-paper based immunodevice is applied to the diagnosis of a cancer biomarker in clinical serum samples.
Technology Reinvestment Project Manufacturing Education and Training. Volume 1
NASA Technical Reports Server (NTRS)
Schroer, Bernard J.; Bond, Arthur J.
1997-01-01
The manufacturing education program is a joint program between the University of Alabama in Huntsville's (UAH) College of Engineering and Alabama A&M University's (AAMLJ) School of Engineering and Technology. The objective of the program is to provide more hands-on experiences to undergraduate engineering and engineering technology students. The scope of work consisted of. Year 1, Task 1: Review courses at Alabama Industrial Development Training (AIDT); Task 2: Review courses at UAH and AAMU; Task 3: Develop new lab manuals; Task 4: Field test manuals; Task 5: Prepare annual report. Year 2, Task 1: Incorporate feedback into lab manuals; Task 2 : Introduce lab manuals into classes; Task 3: Field test manuals; Task 4: Prepare annual report. Year 3, Task 1: Incorporate feedback into lab manuals; Task 2: Introduce lab manuals into remaining classes; Task 3: Conduct evaluation with assistance of industry; Task 4: Prepare final report. This report only summarizes the activities of the University of Alabama in Huntsville. The activities of Alabama A&M University are contained in a separate report.
Cohen-Bacrie, Stéphan; Ninove, Laetitia; Nougairède, Antoine; Charrel, Rémi; Richet, Hervé; Minodier, Philippe; Badiaga, Sékéné; Noël, Guilhem; La Scola, Bernard; de Lamballerie, Xavier; Drancourt, Michel; Raoult, Didier
2011-01-01
Clinical microbiology may direct decisions regarding hospitalization, isolation and anti-infective therapy, but it is not effective at the time of early care. Point-of-care (POC) tests have been developed for this purpose. One pilot POC-lab was located close to the core laboratory and emergency ward to test the proof of concept. A second POC-lab was located inside the emergency ward of a distant hospital without a microbiology laboratory. Twenty-three molecular and immuno-detection tests, which were technically undemanding, were progressively implemented, with results obtained in less than four hours. From 2008 to 2010, 51,179 tests yielded 6,244 diagnoses. The second POC-lab detected contagious pathogens in 982 patients who benefited from targeted isolation measures, including those undertaken during the influenza outbreak. POC tests prevented unnecessary treatment of patients with non-streptococcal tonsillitis (n = 1,844) and pregnant women negative for Streptococcus agalactiae carriage (n = 763). The cerebrospinal fluid culture remained sterile in 50% of the 49 patients with bacterial meningitis, therefore antibiotic treatment was guided by the molecular tests performed in the POC-labs. With regard to enterovirus meningitis, the mean length-of-stay of infected patients over 15 years old significantly decreased from 2008 to 2010 compared with 2005 when the POC was not in place (1.43±1.09 versus 2.91±2.31 days; p = 0.0009). Altogether, patients who received POC tests were immediately discharged nearly thrice as often as patients who underwent a conventional diagnostic procedure. The on-site POC-lab met physicians' needs and influenced the management of 8% of the patients that presented to emergency wards. This strategy might represent a major evolution of decision-making regarding the management of infectious diseases and patient care.
El-Fawal, Gomaa F; Yassin, Abdelrahman M; El-Deeb, Nehal M
2017-07-01
Material barrier properties to microbes are an important issue in many pharmaceutical applications like wound dressings. A wide range of biomaterials has been used to manage the chronic inflamed wounds. Eight hydrogel membranes of poly vinyl alcohol (PVA) with κ-carrageenan (KC) and Lactobacillus bulgaricus extract (LAB) have been prepared by using freeze-thawing technique. To evaluate the membranes efficiency as wound dressing agents, various tests have been done like gel fraction, swelling behavior, mechanical properties, etc. The antibacterial activities of the prepared membranes were tested against the antibiotic-resistant bacterial isolates. In addition, the safety usage of the prepared hydrogel was checked on human dermal fibroblast cells. The anti-inflammatory properties of the prepared hydrogel on LPS-PBMC cell inflammatory model were quantified using enzyme-linked immunosorbent assay (ELISA) and real-time polymerase chain reaction (RT-qPCR). The analysis data of TGA, SEM, gel fraction, and swelling behavior showed changes in properties of prepared PVA\\KC\\LAB hydrogel membrane than pure PVA hydrogel membrane. The antibacterial activities of the prepared membranes augmented in LAB extract-prepared membranes. Out of the eight used hydrogel membranes, the PVAKC4 hydrogel membrane is the safest one on fibroblast cellular proliferation with a maximum proliferation percentage 97.3%. Also, all the used hydrogel membrane showed abilities to reduce the concentration of IL-2 and IL-8 compared with both negative and positive control. In addition, almost all the prepared hydrogel membrane showed variable abilities to downregulate the expression of TNF-α gene with superior effect of hydrogel membrane KC1. PVA/KC/LAB extract hydrogel membrane may be a promising material for wound dressing application and could accelerate the healing process of the chronic wound because of its antimicrobial and anti-inflammatory properties.
Handedness, Earnings, Ability and Personality. Evidence from the Lab
2016-01-01
Evidence showing that on average left-handed (L), who are 10% in a population, tend to earn less than others is solely based on survey data. This paper is the first to test the relationship between handedness and earnings experimentally and also to assess whether the mechanism underlying it is predominantly cognitive or psychological. Data on 432 undergraduate students show that L do not obtain significantly different payoffs, a proxy for earnings, in a stylised labour market with multiple principals and agents. Similarly, scores in the Cognitive Reflection Test are not significantly different. Data on personality, measured using the Big Five test, show, instead, that L are significantly more agreeable and L females more extroverted. In addition, earnings significantly vary with personality only for L, increasing with extraversion and decreasing with neuroticism. Overall, our results fail to reject the null hypothesis that earnings do not differ by handedness and suggest differences in personality as a novel mechanism to rationalise L’s behaviour. PMID:27788156
Customer Avionics Interface Development and Analysis (CAIDA) Lab DEWESoft Display Creation
NASA Technical Reports Server (NTRS)
Coffey, Connor
2015-01-01
The Customer Avionics Interface Development and Analysis (CAIDA) Lab supports the testing of the Launch Control System (LCS), NASA's command and control system for the Space Launch System (SLS), Orion Multi-Purpose Crew Vehicle (MPCV), and ground support equipment. The objectives of the year-long internship were to support day-to-day operations of the CAIDA Lab, create prelaunch and tracking displays for Orion's Exploration Flight Test 1 (EFT-1), and create a program to automate the creation of displays for SLS and MPCV to be used by CAIDA and the Record and Playback Subsystem (RPS).
How to Structure University/Industry Cooperation for Maximum Mutual Benefit
NASA Astrophysics Data System (ADS)
Sommer, Klaus H.
2000-03-01
Research in the technical industries has changed dramatically in the past twenty years. As part of the change, many companies have shifted their long-term research from within company labs to university labs using a variety of mechanisms for such "cooperations." This talk focuses on how Bayer Corporation uses contract research, unrestricted funds, consortia, and government contracts to supplement in-house research programs. The talk emphasizes the importance of careful tailoring of these mechanisms in order to achieve maximum success for both the company and its university partners.
NASA Astrophysics Data System (ADS)
Lukishova, Svetlana G.
2017-08-01
At the Institute of Optics, University of Rochester (UR), we have adapted to the main challenge (the lack of space in the curriculum) by developing a series of modular 3-hour experiments and 20-min-demonstrations based on technical elective, 4-credit-hour laboratory course "Quantum Optics and Nano-Optics Laboratory" (OPT 253/OPT453/PHY434), that were incorporated into a number of required courses ranging from freshman to senior level. Rochester Monroe Community College (MCC) students also benefited from this facility that was supported by four NSF grants. MCC students carried out two 3-hour labs on photon quantum mechanics at the UR. Since 2006, total 566 students passed through the labs with lab reports submission (including 144 MCC students) and more than 250 students through lab demonstrations. In basic class OPT 253, four teaching labs were prepared on generation and characterization of entangled and single (antibunched) photons demonstrating the laws of quantum mechanics: (1) entanglement and Bell's inequalities, (2) single-photon interference (Young's double slit experiment and Mach-Zehnder interferometer), (3) confocal microscope imaging of single-emitter (colloidal nanocrystal quantum dots and NV-center nanodiamonds) fluorescence within photonic (liquid crystal photonic bandgap microcavities) or plasmonic (gold bowtie nanoantennas) nanostructures, (4) Hanbury Brown and Twiss setup. Fluorescence antibunching from nanoemitters. Students also carried out measurements of nanodiamond topography using atomic force microscopy and prepared photonic bandgap materials from cholesteric liquid crystals. Manuals, student reports, presentations, lecture materials and quizzes, as well as some NSF grants' reports are placed on a website http://www.optics.rochester.edu/workgroups/lukishova/QuantumOpticsLab/ . In 2011 UR hosted 6 professors from different US universities in three-days training of these experiments participating in the Immersion Program of the Advanced Laboratory Physics Association.
DOT National Transportation Integrated Search
2002-07-25
The Bituminous Mixtures Laboratory (BML) specializes in the research of asphalt pavement mixtures. This lab supports FHWA's efforts to develop, evaluate and improve materials, mixture design technology and performance-based tests for asphalt paving m...
Stress Physiology of Lactic Acid Bacteria.
Papadimitriou, Konstantinos; Alegría, Ángel; Bron, Peter A; de Angelis, Maria; Gobbetti, Marco; Kleerebezem, Michiel; Lemos, José A; Linares, Daniel M; Ross, Paul; Stanton, Catherine; Turroni, Francesca; van Sinderen, Douwe; Varmanen, Pekka; Ventura, Marco; Zúñiga, Manuel; Tsakalidou, Effie; Kok, Jan
2016-09-01
Lactic acid bacteria (LAB) are important starter, commensal, or pathogenic microorganisms. The stress physiology of LAB has been studied in depth for over 2 decades, fueled mostly by the technological implications of LAB robustness in the food industry. Survival of probiotic LAB in the host and the potential relatedness of LAB virulence to their stress resilience have intensified interest in the field. Thus, a wealth of information concerning stress responses exists today for strains as diverse as starter (e.g., Lactococcus lactis), probiotic (e.g., several Lactobacillus spp.), and pathogenic (e.g., Enterococcus and Streptococcus spp.) LAB. Here we present the state of the art for LAB stress behavior. We describe the multitude of stresses that LAB are confronted with, and we present the experimental context used to study the stress responses of LAB, focusing on adaptation, habituation, and cross-protection as well as on self-induced multistress resistance in stationary phase, biofilms, and dormancy. We also consider stress responses at the population and single-cell levels. Subsequently, we concentrate on the stress defense mechanisms that have been reported to date, grouping them according to their direct participation in preserving cell energy, defending macromolecules, and protecting the cell envelope. Stress-induced responses of probiotic LAB and commensal/pathogenic LAB are highlighted separately due to the complexity of the peculiar multistress conditions to which these bacteria are subjected in their hosts. Induction of prophages under environmental stresses is then discussed. Finally, we present systems-based strategies to characterize the "stressome" of LAB and to engineer new food-related and probiotic LAB with improved stress tolerance. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
1996-12-17
A knee brace that uses Space Shuttle propulsion technology has moved a step closer to being available to help knee injury and stroke patients and may possibly benefit patients with birth defects, spinal cord injuries, and post-polio conditions. After years of hard work, inventors at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, have turned over the final design and prototype to industry partners at Horton's Orthotic Lab in Little Rock, Arkansas for further clinical testing. The device, called the Selectively Lockable Knee Brace, may mean faster, less painful rehabilitation for patients by allowing the knee to move when weight is not on the heel. Devices currently on the market lock the knee in a rigid, straight-leg position, or allow continuous free motion. Pictured here is a knee brace prototype being tested and fitted at Horton's Orthotic Lab. The knee brace is just one example of how space technology is being used to improve the lives of people on Earth. NASA's MSFC inventors Michael Shadoan and Neill Myers are space propulsion engineers who use the same mechanisms and materials to build systems for rockets that they used to design and develop the knee brace.
A multilevel Lab on chip platform for DNA analysis.
Marasso, Simone Luigi; Giuri, Eros; Canavese, Giancarlo; Castagna, Riccardo; Quaglio, Marzia; Ferrante, Ivan; Perrone, Denis; Cocuzza, Matteo
2011-02-01
Lab-on-chips (LOCs) are critical systems that have been introduced to speed up and reduce the cost of traditional, laborious and extensive analyses in biological and biomedical fields. These ambitious and challenging issues ask for multi-disciplinary competences that range from engineering to biology. Starting from the aim to integrate microarray technology and microfluidic devices, a complex multilevel analysis platform has been designed, fabricated and tested (All rights reserved-IT Patent number TO2009A000915). This LOC successfully manages to interface microfluidic channels with standard DNA microarray glass slides, in order to implement a complete biological protocol. Typical Micro Electro Mechanical Systems (MEMS) materials and process technologies were employed. A silicon/glass microfluidic chip and a Polydimethylsiloxane (PDMS) reaction chamber were fabricated and interfaced with a standard microarray glass slide. In order to have a high disposable system all micro-elements were passive and an external apparatus provided fluidic driving and thermal control. The major microfluidic and handling problems were investigated and innovative solutions were found. Finally, an entirely automated DNA hybridization protocol was successfully tested with a significant reduction in analysis time and reagent consumption with respect to a conventional protocol.
New Generation Lockable Knee Brace
NASA Technical Reports Server (NTRS)
1996-01-01
A knee brace that uses Space Shuttle propulsion technology has moved a step closer to being available to help knee injury and stroke patients and may possibly benefit patients with birth defects, spinal cord injuries, and post-polio conditions. After years of hard work, inventors at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, have turned over the final design and prototype to industry partners at Horton's Orthotic Lab in Little Rock, Arkansas for further clinical testing. The device, called the Selectively Lockable Knee Brace, may mean faster, less painful rehabilitation for patients by allowing the knee to move when weight is not on the heel. Devices currently on the market lock the knee in a rigid, straight-leg position, or allow continuous free motion. Pictured here is a knee brace prototype being tested and fitted at Horton's Orthotic Lab. The knee brace is just one example of how space technology is being used to improve the lives of people on Earth. NASA's MSFC inventors Michael Shadoan and Neill Myers are space propulsion engineers who use the same mechanisms and materials to build systems for rockets that they used to design and develop the knee brace.
ERIC Educational Resources Information Center
Stanley, Jacob T.; Su, Weifeng; Lewandowski, H. J.
2017-01-01
We demonstrate how students' use of modeling can be examined and assessed using student notebooks collected from an upper-division electronics lab course. The use of models is a ubiquitous practice in undergraduate physics education, but the process of constructing, testing, and refining these models is much less common. We focus our attention on…
NASA Technical Reports Server (NTRS)
Beheshti, Afshin
2018-01-01
GeneLab as a general tool for the scientific community; Utilizing GeneLab datasets to generate hypothesis and determining potential biological targets against health risks due to long-term space missions; How can OpenTarget be used to discover novel drugs to test as countermeasures that can be utilized by astronauts.
A&M. TAN607 second floor plan for cold assembly area. Metallurgical ...
A&M. TAN-607 second floor plan for cold assembly area. Metallurgical lab, chemistry lab, nuclear instrument lab, equipment rooms. Ralph M. Parsons 902-ANP-607-A 102. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-693-106754 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Online versus in the Classroom: Student Success in a Hands-On Lab Class
ERIC Educational Resources Information Center
Reuter, Ron
2009-01-01
This study compares learning success of online and on-campus students in a general education soil science course with lab and field components. Two terms of students completed standardized pre- and postassessments designed to test knowledge and skills from the lecture and lab content of the course. There was no difference in overall grade or lab…
Pratt and Whitney Overview and Advanced Health Management Program
NASA Technical Reports Server (NTRS)
Inabinett, Calvin
2008-01-01
Hardware Development Activity: Design and Test Custom Multi-layer Circuit Boards for use in the Fault Emulation Unit; Logic design performed using VHDL; Layout power system for lab hardware; Work lab issues with software developers and software testers; Interface with Engine Systems personnel with performance of Engine hardware components; Perform off nominal testing with new engine hardware.
Are They Bloody Guilty? Blood Doping with Simulated Samples
ERIC Educational Resources Information Center
Stuart, Parker E.; Lees, Kelsey D.; Milanick, Mark A.
2014-01-01
In this practice-based lab, students are provided with four Olympic athlete profiles and simulated blood and urine samples to test for illegal substances and blood-doping practices. Throughout the course of the lab, students design and conduct a testing procedure and use their results to determine which athletes won their medals fairly. All of the…
Biochar: from laboratory mechanisms through the greenhouse to field trials
NASA Astrophysics Data System (ADS)
Masiello, C. A.; Gao, X.; Dugan, B.; Silberg, J. J.; Zygourakis, K.; Alvarez, P. J. J.
2014-12-01
The biochar community is excellent at pointing to individual cases where biochar amendment has changed soil properties, with some studies showing significant improvements in crop yields, reduction in nutrient export, and remediation of pollutants. However, many studies exist which do not show improvements, and in some cases, studies clearly show detrimental outcomes. The next, crucial step in biochar science and engineering research will be to develop a process-based understanding of how biochar acts to improve soil properties. In particular, we need a better mechanistic understanding of how biochar sorbs and desorbs contaminants, how it interacts with soil water, and how it interacts with the soil microbial community. These mechanistic studies need to encompass processes that range from the nanometer to the kilometer scale. At the nanometer scale, we need a predictive model of how biochar will sorb and desorb hydrocarbons, nutrients, and toxic metals. At the micrometer scale we need models that explain biochar's effects on soil water, especially the plant-available fraction of soil water. The micrometer scale is also where mechanistic information is neeed about microbial processes. At the macroscale we need physical models to describe the landscape mobility of biochar, because biochar that washes away from fields can no longer provide crop benefits. To be most informative, biochar research should occur along a lab-greenhouse-field trial trajectory. Laboratory experiments should aim determine what mechanisms may act to control biochar-soil processes, and then greenhouse experiments can be used to test the significance of lab-derived mechanisms in short, highly replicated, controlled experiments. Once evidence of effect is determined from greenhouse experiments, field trials are merited. Field trials are the gold standard needed prior to full deployment, but results from field trials cannot be extrapolated to other field sites without the mechanistic backup provided by greenhouse and lab trials.
Costello, P J; Siebert, T E; Solomon, M R; Bartowsky, E J
2013-03-01
To assess the abilities of commercial wine lactic acid bacteria (LAB) to synthesize potentially flavour active fatty acid ethyl esters and determine mechanisms involved in their production. Oenococcus oeni AWRI B551 produced significant levels of ethyl hexanoate and ethyl octanoate following growth in an ethanolic test medium, and ester formation generally increased with increasing pH (4.5 > 3.5), anaerobiosis and precursor supplementation. Cell-free extracts of commercial O. oeni strains and Lactobacillus plantarum AWRI B740 were also tested for ester-synthesizing capabilities in a phosphate buffer via: (i) acyl coenzyme A: alcohol acyltransferase (AcoAAAT) activity and (ii) reverse esterase activity. For both ester-synthesizing activities, strain-dependent variation was observed, with AcoAAAT activity generally greater than reverse esterase. Reverse esterase in O. oeni AWRI B551 also esterified 1-propanol to produce propyl octanoate, and deuterated substrates ([(2)H(6)]ethanol and [(2)H(15)]octanoic acid) to produce the fully deuterated ester, [(2)H(5)]ethyl [(2)H(15)]octanoate. Wine LAB exhibit ethyl ester-synthesizing capability and possess two different ester-synthesizing activities, one of which is associated with an acyl coenzyme A: alcohol acyltransferase. This study demonstrates that wine LAB exhibit enzyme activities that can augment the ethyl ester content of wine. This knowledge will facilitate greater control over the impacts of malolactic fermentation on the fruity sensory properties and quality of wine. © 2012 Australian Wine Research Institute © 2012 The Society for Applied Microbiology.
The laboratory report: A pedagogical tool in college science courses
NASA Astrophysics Data System (ADS)
Ferzli, Miriam
When viewed as a product rather than a process that aids in student learning, the lab report may become rote, busywork for both students and instructors. Students fail to see the purpose of the lab report, and instructors see them as a heavy grading load. If lab reports are taught as part of a process rather than a product that aims to "get the right answer," they may serve as pedagogical tools in college science courses. In response to these issues, an in-depth, web-based tutorial named LabWrite (www.ncsu.edu/labwrite) was developed to help students and instructors (www.ncsu.edu/labwrite/instructors) understand the purpose of the lab report as grounded in the written discourse and processes of science. The objective of this post-test only quasi-experimental study was to examine the role that in-depth instruction such as LabWrite plays in helping students to develop skills characteristic of scientifically literate individuals. Student lab reports from an introductory-level biology course at NC State University were scored for overall understanding of scientific concepts and scientific ways of thinking. The study also looked at students' attitudes toward science and lab report writing, as well as students' perceptions of lab reports in general. Significant statistical findings from this study show that students using LabWrite were able to write lab reports that showed a greater understanding of scientific investigations (p < .003) and scientific ways of thinking (p < .0001) than students receiving traditional lab report writing instruction. LabWrite also helped students develop positive attitudes toward lab reports as compared to non-LabWrite users (p < .01). Students using LabWrite seemed to perceive the lab report as a valuable tool for determining learning objectives, understanding science concepts, revisiting the lab experience, and documenting their learning.
None
2018-01-16
Take a virtual tour of the campus of Thomas Jefferson National Accelerator Facility. You can see inside our two accelerators, three experimental areas, accelerator component fabrication and testing areas, high-performance computing areas and laser labs.
Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomae, R., E-mail: rthomae@tlabs.ac.za; Conradie, J.; Fourie, D.
2016-02-15
At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the resultsmore » of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.« less
NASA Technical Reports Server (NTRS)
Tobey, G. L.
1978-01-01
Tests were performed to evaluate the operating characteristics of the interface between the Space Lab Bus Interface Unit (SL/BIU) and the Orbiter Multiplexer-Demultiplexer (MDM) serial data input-output (SIO) module. This volume contains the test equipment preparation procedures and a detailed description of the Nova/Input Output Processor Simulator (IOPS) software used during the data transfer tests to determine word error rates (WER).
Engelskirchen, Simon; Ehlers, Jan; Kirk, Ansgar T; Tipold, Andrea; Dilly, Marc
2017-09-20
During five and a half years of studying veterinary medicine, students should in addition to theoretical knowledge acquire sufficient practical skills. Considering animal welfare and ethical aspects, opportunities for hands-on learning on living animals are limited because of the high annual number of students. The first German veterinary clinical-skills lab, established in 2013 at the University for Veterinary Medicine Hannover, Foundation (TiHo), offers opportunities for all students to learn, train and repeat clinical skills on simulators and models as frequently as they would like, until they feel sufficiently confident to transfer these skills to living animals. This study describes the establishment of clinical-skills lab training within the students' practical education, using the example of the small-animal clinic of the TiHo. Two groups of students were compared: without skills lab training (control group K) and with skills lab training (intervention group I). At the end of both the training and a subsequent 10-week clinical rotation in different sections of the clinic, an objective structured clinical examination (OSCE) was performed, testing the students' practical skills at 15 stations. An additional multiple-choice test was performed before and after the clinical rotation to evaluate the increased theoretical knowledge. Students of group I achieved significantly (p ≤ 0.05) better results in eight of the 15 tested skills. The multiple-choice test revealed a significant (p ≤ 0.05) gain of theoretical knowledge in both groups without any differences between the groups. Students displayed a high degree of acceptance of the skills lab training. Using simulators and models in veterinary education is an efficient teaching concept, and should be used continually and integrated in the curriculum.
James, Carl Alexander; Vallejo, Florencio Tenllado; Kantebeen, Melvin; Farra, Saro
2018-02-14
Current on-court assessments of aerobic fitness in squash are not designed to yield a wealth of physiological data. Moreover, tests may require complex computer equipment or involve simulated racket strokes, which are difficult to standardize at high intensities. This study investigated the validity and reliability of a squash-specific fitness test which can yield both a standalone performance score, as well as pertinent physiological markers such as V[Combining Dot Above]O2max, the lactate turnpoint and oxygen cost, in a sport-specific environment. Eight national squash players completed three tests in a counter-balanced order; an incremental laboratory treadmill test (LAB) and two on-court fitness tests (ST) that involved repeated shuttle runs at increasing speeds. V[Combining Dot Above]O2max during ST was agreeable with LAB (Typical error [TE]=3.3 mL.kg.min, r=0.79). The mean bias between LAB and ST was 2.5 mL.kg.min. There were no differences in maximum heart rate, post exercise blood lactate concentration or end of test RPE between LAB and ST (p>0.05). The ST was highly reliable, with 74 (10) laps completed in ST1 and 75 (12) laps in ST2 (mean bias=1 lap, TE=3 laps, r=0.97). Physiological markers were also reliable, including V[Combining Dot Above]O2max, (TE=1.5 mL.kg.min, r=0.95), the lap number at 4 mMol (TE=4 laps, r=0.77) and average VO2 across the first 4 stages (TE=0.94 mL.kg.min, r=0.95). We observed good agreement between LAB and ST for assessing V[Combining Dot Above]O2max and between both on-court trials for assessing test performance and selected physiological markers. Consequently, we recommend this test for monitoring training adaptations and prescribing individualized training in elite squash players.
Playing with Light: Adventures in Optics and Spectroscopy for Honors and Majors General Chemistry
ERIC Educational Resources Information Center
van Staveren, Marie N.; Edwards, Kimberly D.; Apkarian, V. A.
2012-01-01
A lab was developed for use in an undergraduate honors and majors general chemistry laboratory to introduce students to optics, spectroscopy, and the underlying principles of quantum mechanics. This lab includes four mini-experiments exploring total internal reflection, the tunneling of light, spectra of sparklers and colored candles, and emission…
Genís, Sandra; Sánchez-Chardi, Alejandro; Bach, Àlex; Fàbregas, Francesc; Arís, Anna
2017-01-01
Uterine function in cattle is compromised by bacterial contamination and inflammation after calving. The objective of this study was to select a combination of lactic acid bacteria (LAB) to decrease endometrium inflammation and Escherichia coli infection. Primary endometrial epithelial cells were cultured in vitro to select the most favorable LAB combination modulating basal tissue inflammation and E. coli infection. Supernatants were obtained to determine expression of pro-inflammatory cytokines, and E. coli infection was evaluated after harvesting the tissue and plate counting. The selected LAB combination was tested in uterus explants to assess its capacity to modulate basal and acute inflammation (associated with E. coli infection). The combination of Lactobacillus rhamnosus, Pediococcus acidilactici, and Lactobacillus reuteri at a ratio of 25:25:2, respectively, reduced E. coli infection in vitro with (89.77%) or without basal tissue inflammation (95.10%) compared with single LAB strains. Lactic acid bacteria treatment reduced CXCL8 and IL1B expression 4.7- and 2.2-fold, respectively, under acute inflammation. Ex vivo, the tested LAB combination reduced acute inflammation under E. coli infection, decreasing IL-8, IL-1β, and IL-6 up to 2.2-, 2.5-, and 2.2-fold, respectively. In the total inflammation model, the LAB combination decreased IL-8 1.6-fold and IL-6 1.2-fold. Ultrastructural evaluation of the tissue suggested no direct interaction between the LAB and E. coli, although pathological effects of E. coli in endometrial cells were greatly diminished or even reversed by the LAB combination. This study shows the promising potential of LAB probiotics for therapeutic use against endometrial inflammation and infection. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhao, Yunli; Yu, Xiaoming; Jia, Ruhan; Yang, Ruilong; Rui, Qi; Wang, Dayong
2015-11-01
Lactic acid bacteria (LAB) is safe and useful for food and feed fermentation. We employed Caenorhabditis elegans to investigate the possible beneficial effect of LAB (Lactobacillus bulgaricus) pretreatment against toxicity of graphene oxide (GO) and the underlying mechanisms. LAB prevented GO toxicity on the functions of both primary and secondary targeted organs in wild-type nematodes. LAB blocked translocation of GO into secondary targeted organs through intestinal barrier by maintaining normal intestinal permeability in wild-type nematodes. Moreover, LAB prevented GO damage on the functions of both primary and secondary targeted organs in exposed nematodes with mutations of susceptible genes (sod-2, sod-3, gas-1, and aak-2) to GO toxicity by sustaining normal intestinal permeability. LAB also sustained the normal defecation behavior in both wild-type nematodes and nematodes with mutations of susceptible genes. Therefore, the beneficial role of LAB against GO toxicity under different genetic backgrounds may be due to the combinational effects on intestinal permeability and defecation behavior. Moreover, the beneficial effects of LAB against GO toxicity was dependent on the function of ACS-22, homologous to mammalian FATP4 to mammalian FATP4. Our study provides highlight on establishment of pharmacological strategy to protect intestinal barrier from toxicity of GO.
In situ stimulation of groundwater denitrification with formate to remediate nitrate contamination
Smith, R.L.; Miller, D.N.; Brooks, M.H.; Widdowson, M.A.; Killingstad, M.W.
2001-01-01
In situ stimulation of denitrification has been proposed as a mechanism to remediate groundwater nitrate contamination. In this study, sodium formate was added to a sand and gravel aquifer on Cape Cod, MA, to test whether formate could serve as a potential electron donor for subsurface denitrification. During 16- and 10-day trials, groundwater from an anoxic nitrate-containing zone (0.5-1.5 mM) was continuously withdrawn, amended with formate and bromide, and pumped back into the aquifer. Concentrations of groundwater constituents were monitored in multilevel samplers after up to 15 m of transport by natural gradient flow. Nitrate and formate concentrations were decreased 80-100% and 60-70%, respectively, with time and subsequent travel distance, while nitrite concentrations inversely increased. The field experiment breakthrough curves were simulated with a two-dimensional site-specific model that included transport, denitrification, and microbial growth. Initial values for model parameters were obtained from laboratory incubations with aquifer core material and then refined to fit field breakthrough curves. The model and the lab results indicated that formate-enhanced nitrite reduction was nearly 4-fold slower than nitrate reduction, but in the lab, nitrite was completely consumed with sufficient exposure time. Results of this study suggest that a long-term injection of formate is necessary to test the remediation potential of this approach for nitrate contamination and that adaptation to nitrite accumulation will be a key determinative factor.In situ stimulation of denitrification has been proposed as a mechanism to remediate groundwater nitrate contamination. In this study, sodium formate was added to a sand and gravel aquifer on Cape Cod, MA, to test whether formate could serve as a potential electron donor for subsurface denitrification. During 16- and 10-day trials, groundwater from an anoxic nitrate-containing zone (0.5-1.5 mM) was continuously withdrawn, amended with formate and bromide, and pumped back into the aquifer. Concentrations of groundwater constituents were monitored in multilevel samplers after up to 15 m of transport by natural gradient flow. Nitrate and formate concentrations were decreased 80-100% and 60-70%, respectively, with time and subsequent travel distance, while nitrite concentrations inversely increased. The field experiment breakthrough curves were simulated with a two-dimensional site-specific model that included transport, denitrification, and microbial growth. Initial values for model parameters were obtained from laboratory incubations with aquifer core material and then refined to fit field breakthrough curves. The model and the lab results indicated that formate-enhanced nitrite reduction was nearly 4-fold slower than nitrate reduction, but in the lab, nitrite was completely consumed with sufficient exposure time. Results of this study suggest that a long-term injection of formate is necessary to test the remediation potential of this approach for nitrate contamination and that adaptation to nitrite accumulation will be a key determinative factor.
Who is more efficient: Teacher or pedagogical agents?
NASA Astrophysics Data System (ADS)
Lee, Tien Tien; Mustapha, Nur Hanani
2017-05-01
The purpose of the study is to investigate the impact of pedagogical agent's and teacher's role on students' understanding and motivation in the learning of Electrochemistry. Interactive Multimedia Module with Pedagogical Agents, EC Lab (IMMPA EC Lab) was used in this study. IMMPA EC Lab consists of five subunits in Electrochemistry topic. The research was a non-equivalent control group quasi experimental design involving two treatment groups and one control group. The first treatment group studied Electrochemistry with expert agent (Professor T) while the second treatment group studied Electrochemistry with learning companion agent (Lisa). On the other hand, the control group learned Electrochemistry with their Chemistry teacher using the material in the IMMPA EC Lab. The study was conducted at a secondary science school in the Pasir Puteh district involving 74 form four students. The instruments used in this research were the Electrochemistry achievement tests in the form of pre-test and post-test, IMMPA EC Lab and motivation questionnaire. ANCOVA results found that there was no significant difference among the three groups in post-test. On the other hand, One-way ANOVA test proved that there were significant differences for the post-motivation scores between the control group and the treatment groups. Post motivation mean scores for expert agent treatment group and learning companion treatment group surpassed the control group. The study focus on the impact of pedagogical agents with different roles on students' learning and motivation should be promoted. Various versions of pedagogical agents that fulfil the good characteristics should be designed to enhance students' learning and motivation.
Beta-Catenin Stability in Breast Cancer
1999-09-01
monoclonal anti-ß-catenin antibody (Clone#14) and the anti-FLAG™ antibody were purchased from Transduction Labs and Kodak, respectively. Affinity purified...anti-HA (BabCo) and anti-ß-catenin antibodies (Transduction labs ). To test the hypothesis that the tumor suppressor adenomatous polyposis coli (APC...ß-catenin was detected first using 1:50 dilution of a mouse monoclonal antibody (Transduction Labs ) followed by Texas Red-conjugated goat anti
DNA Microarray Wet Lab Simulation Brings Genomics into the High School Curriculum
ERIC Educational Resources Information Center
Campbell, A. Malcolm; Zanta, Carolyn A.; Heyer, Laurie J.; Kittinger, Ben; Gabric, Kathleen M.; Adler, Leslie
2006-01-01
We have developed a wet lab DNA microarray simulation as part of a complete DNA microarray module for high school students. The wet lab simulation has been field tested with high school students in Illinois and Maryland as well as in workshops with high school teachers from across the nation. Instead of using DNA, our simulation is based on pH…
Innovative Use of a Classroom Response System During Physics Lab
NASA Astrophysics Data System (ADS)
Walgren, Jay
2011-01-01
More and more physics instructors are making use of personal/classroom response systems or "clickers." The use of clickers to engage students with multiple-choice questions during lecture and available instructor resources for clickers have been well documented in this journal.1-4 Newer-generation clickers, which I refer to as classroom response systems (CRS), have evolved to accept numeric answers (such as 9.81) instead of just single "multiple-choice" entries (Fig. 1). This advancement is available from most major clicker companies and allows for a greater variety of engaging questions during lecture. In addition, these new "numeric ready" clickers are marketed to be used for student assessments. During a test or quiz, students' answers are entered into their clicker instead of on paper or Scantron® and immediately absorbed by wireless connection into a computer for grading and analysis. I recognize the usefulness and benefit these new-generation CRSs provide for many instructors. However, I do not use my CRS in either of the aforementioned activities. Instead, I use it in an unconventional way. I use the CRS to electronically capture students' lab data as they are performing a physics lab (Fig. 2). I set up the clickers as if I were going to use them for a test, but instead of entering answers to a test, my students enter lab data as they collect it. In this paper I discuss my use of a classroom response system during physics laboratory and three benefits that result: 1) Students are encouraged to "take ownership of" and "have integrity with" their physics lab data. 2) Students' measuring and unit conversion deficiencies are identified immediately during the lab. 3) The process of grading students' labs is simplified because the results of each student's lab calculations can be pre-calculated for the instructor using a spreadsheet. My use of clickers during lab can be implemented with most clicker systems available to instructors today. The CRS I use is the eInstruction's® Classroom Performance System™ (CPS™).5 (Fig. 1)
Peer assessment of student-produced mechanics lab report videos
NASA Astrophysics Data System (ADS)
Douglas, Scott S.; Aiken, John M.; Lin, Shih-Yin; Greco, Edwin F.; Alicea-Muñoz, Emily; Schatz, Michael F.
2017-12-01
We examine changes in students' rating behavior during a semester-long sequence of peer evaluation laboratory exercises in an introductory mechanics course. We perform a quantitative analysis of the ratings given by students to peers' physics lab reports, and conduct interviews with students. We find that peers persistently assign higher ratings to lab reports than do experts, that peers begin the semester by giving high ratings most frequently and end the semester with frequent middle ratings, and that peers go through the semester without much change in the frequency of low ratings. We then use student interviews to develop a model for student engagement with peer assessment. This model is based on two competing influences which appear to shape peer evaluation behavior: a strong disinclination to give poor ratings with a complementary preference to give high ratings when in doubt, and an attempt to develop an expertlike criticality when assessing peers' work.
MTR WING, TRA604. FIRST FLOOR PLAN. ENTRY LOBBY, MACHINE SHOP, ...
MTR WING, TRA-604. FIRST FLOOR PLAN. ENTRY LOBBY, MACHINE SHOP, INSTRUMENT SHOP, COUNTING ROOM, HEALTH PHYSICS LAB, LABS AND OFFICES, STORAGE, SHIPPING AND RECEIVING. BLAW-KNOX 3150-4-2, 7/1950. INL INDEX NO. 053-604-00-099-100008, REV. 7. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lombardi, A., E-mail: a2lombar@ryerson.ca; D'Elia, F.; Ravindran, C.
2014-01-15
In recent years, aluminum alloy gasoline engine blocks have in large part successfully replaced nodular cast iron engine blocks, resulting in improved vehicle fuel efficiency. However, because of the inadequate wear resistance properties of hypoeutectic Al–Si alloys, gray iron cylinder liners are required. These liners cause the development of large tensile residual stress along the cylinder bores and necessitate the maximization of mechanical properties in this region to prevent premature engine failure. The aim of this study was to replicate the engine cylinder bridge microstructure and mechanical properties following TSR treatment (which removes the sand binder to enable easy castingmore » retrieval) using lab scale billet castings of the same alloy composition with varying cooling rates. Comparisons in microstructure between the engine block and the billet castings were carried out using optical and scanning electron microscopy, while mechanical properties were assessed using tensile testing. The results suggest that the microstructure at the top and middle of the engine block cylinder bridge was successfully replicated by the billet castings. However, the microstructure at the bottom of the cylinder was not completely replicated due to variations in secondary phase morphology and distribution. The successful replication of engine block microstructure will enable the future optimization of heat treatment parameters. - Highlights: • A method to replicate engine block microstructure was developed. • Billet castings will allow cost effective optimization of heat treatment process. • The replication of microstructure in the cylinder region was mostly successful. • Porosity was more clustered in the billet castings compared to the engine block. • Mechanical properties were lower in billet castings due to porosity and inclusions.« less
Collado, M Carmen; Surono, Ingrid S; Meriluoto, Jussi; Salminen, Seppo
2007-03-01
Traditional fermented buffalo milk in Indonesia (dadih) has been believed to have a beneficial impact on human health, which could be related to the properties of the lactic acid bacteria (LAB) involved in its fermentation process. In previous studies, it was discovered that strains of dadih lactic isolates possessed some beneficial properties in vitro. In the present study, the adhesion capacity of specific LAB isolates from dadih to intestinal mucus was analyzed. Further, the ability to inhibit model human pathogens and displace them from mucus was assessed. The adhesion of tested LAB strains was strain-dependent and varied from 1.4 to 9.8%. The most adhesive Lactobacillus plantarum strain was IS-10506, with 9.8% adhesion. The competition assay between dadih LAB isolates and pathogens showed that a 2-h preincubation with L. plantarum at 37 degrees C significantly reduced pathogen adhesion to mucus. All tested LAB strains displaced and inhibited pathogen adhesion, but the results were strain-specific and dependent on time and pathogen strains. In general, L. plantarum IS-10506 showed the best ability against pathogen adhesion.
The U.S. Lab is moved toward the open floor in the O&C Building
NASA Technical Reports Server (NTRS)
2000-01-01
In the Operations and Checkout Building, the U.S. Lab moves overhead toward the open floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research.
Measuring the charged pion polarizability in the gamma gamma -> pi+pi- reaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawrence, David W.; Miskimen, Rory A.; Mushkarenkov, Alexander Nikolaevich
2013-08-01
Development has begun of a new experiment to measure the charged pion polarizabilitymore » $$\\alpha_{\\pi}-\\beta_{\\pi}$$. The charged pion polarizability ranks among the most important tests of low-energy QCD presently unresolved by experiment. Analogous to precision measurements of $$\\pi^{\\circ}\\rightarrow\\gamma\\gamma$$ that test the intrinsic odd-parity (anomalous) sector of QCD, the pion polarizability tests the intrinsic even-parity sector of QCD. The measurement will be performed using the $$\\gamma\\gamma\\rightarrow\\pi^{+{}}\\pi^{-{}}$$ cross section accessed via the Primakoff mechanism on nuclear targets using the GlueX detector in Hall D at Jefferson Lab. The linearly polarized photon source in Hall-D will be utilized to separate the Primakoff cross-section from coherent $$\\rho^{\\circ}$$ production.« less
1. View of EPA Farm Lab Building 1506, facing south ...
1. View of EPA Farm Lab Building 15-06, facing south - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV
The use of food in chemistry experiments to engage and enrich the teaching in the classroom
NASA Astrophysics Data System (ADS)
Topping, Brian Michael
Students often gain more knowledge out of hands on work. Labs and demonstrations increase knowledge often more than the book work and notes because they motivate interest and provide real world application. In an effort to incorporate labs into chemistry I have developed a unit centered on food in order to teach a variety of concepts and lab techniques to high school students. The study of food can be a tremendous motivator and help students take interest and ownership in the learning process. The unit was evaluated for its effectiveness through the use of a pre and post-test assessments as well as a post survey of students' attitudes towards labs and learning science. This study showed that students' overall conceptual knowledge of the various topics related to food increased as a result of this unit with evidence provided by the post-test scores.
Race to improve student understanding of uncertainty: Using LEGO race cars in the physics lab
NASA Astrophysics Data System (ADS)
Parappilly, Maria; Hassam, Christopher; Woodman, Richard J.
2018-01-01
Laboratories using LEGO race cars were developed for students in an introductory physics topic with a high early drop-out rate. In a 2014 pilot study, the labs were offered to improve students' confidence with experiments and laboratory skills, especially uncertainty propagation. This intervention was extended into the intro level physics topic the next year, for comparison and evaluation. Considering the pilot study, we subsequently adapted the delivery of the LEGO labs for a large Engineering Mechanics cohort. A qualitative survey of the students was taken to gain insight into their perception of the incorporation of LEGO race cars into physics labs. For Engineering, the findings show that LEGO physics was instrumental in teaching students the measurement and uncertainty, improving their lab reporting skills, and was a key factor in reducing the early attrition rate. This paper briefly recalls the results of the pilot study, and how variations in the delivery yielded better learning outcomes. A novel method is proposed for how LEGO race cars in a physics lab can help students increase their understanding of uncertainty and motivate them towards physics practicals.
Development of Low Cost Gas Atomization of Precursor Powders for Simplified ODS Alloy Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Iver
2014-08-05
A novel gas atomization reaction synthesis (GARS) method was developed in this project to enable production (at our partner’s facility) a precursor Ni-Cr-Y-Ti powder with a surface oxide and an internal rare earth (RE) containing intermetallic compound (IMC) phase. Consolidation and heat-treatment experiments were performed at Ames Lab to promote the exchange of oxygen from the surface oxide to the RE intermetallic to form nano-metric oxide dispersoids. Alloy selection was aided by an internal oxidation and serial grinding experiments at Ames Lab and found that Hf-containing alloys may form more stable dispersoids than Ti-containing alloy, i.e., the Hf-containing system exhibitedmore » five different oxide phases and two different intermetallics compared to the two oxide phases and one intermetallic in the Ti-containing alloys. Since the simpler Ti-containing system was less complex to characterize, and make observations on the effects of processing parameters, the Ti-containing system was selected by Ames Lab for experimental atomization trials at our partner. An internal oxidation model was developed at Ames Lab and used to predict the heat treatment times necessary for dispersoid formation as a function of powder size and temperature. A new high-pressure gas atomization (HPGA) nozzle was developed at Ames Lab with the aim of promoting fine powder production at scales similar to that of the high gas-flow and melt-flow of industrial atomizers. The atomization nozzle was characterized using schlieren imaging and aspiration pressure testing at Ames Lab to determine the optimum melt delivery tip geometry and atomization pressure to promote enhanced secondary atomization mechanisms. Six atomization trials were performed at our partner to investigate the effects of: gas atomization pressure and reactive gas concentration on the particle size distribution (PSD) and the oxygen content of the resulting powder. Also, the effect on the rapidly solidified microstructure (as a function of powder size) was investigated at Ames Lab as a function of reactive gas composition and bulk alloy composition. The results indicated that the pulsatile gas atomization mechanism and a significantly enhanced yield of fine powders reported in the literature for this type of process were not observed. Also it was determined that reactive gas may marginally improve the fine powder yield but further experiments are required. The oxygen content in the gas also did not have any detrimental effect on the microstructure (i.e. did not significantly reduce undercooling). On the contrary, the oxygen addition to the atomization gas may have mitigated some potent catalytic nucleation sites, but not enough to significantly alter the microstructure vs. particle size relationship. Overall the downstream injection of oxygen was not found to significantly affect either the particle size distribution or undercooling (as inferred from microstructure and XRD observations) but injection further upstream, including in the gas atomization nozzle, remains to be investigated in later work.« less
ERIC Educational Resources Information Center
Munn, Maureen; Knuth, Randy; Van Horne, Katie; Shouse, Andrew W.; Levias, Sheldon
2017-01-01
This study examines how two kinds of authentic research experiences related to smoking behavior--genotyping human DNA (wet lab) and using a database to test hypotheses about factors that affect smoking behavior (dry lab)--influence students' perceptions and understanding of scientific research and related science concepts. The study used pre and…
ERIC Educational Resources Information Center
Astra, I Made; Nasbey, Hadi; Nugraha, Aditiya
2015-01-01
The aim of this research is to create learning media for senior high school students through an android application in the form of a simulation lab. The method employed in the study is research and development. A simulation lab which has been made subsequently validated by concept and media experts, further empirical testing by teachers and…
NASA Astrophysics Data System (ADS)
Lestari, R. P.; Nissa, C.; Afifah, D. N.; Anjani, G.; Rustanti, N.
2018-02-01
Alternative treatment for metabolic syndrome can be done by providing a diet consist of functional foods or beverages. Synbiotic yoghurt containing binahong leaf extract which high in antioxidant, total LAB and fiber can be selected to reduce the risk of metabolic syndrome. The effect of binahong leaf extract in synbiotic yoghurt against total LAB, antioxidant activity, and acceptance were analyzed. The experiment was done with complete randomized design with addition of binahong leaf extract 0% (control); 0.12%; 0.25%; 0.5% in synbiotic yoghurt. Analysis of total LAB using Total Plate Count test, antioxidant activity using DPPH, and acceptance were analyzed by hedonic test. The addition of binahong leaf extract in various doses in synbiotic yoghurt decreased total LAB without significant effect (p=0,145). There was no effect of addition binahong leaf extract on antioxidant activity (p=0,297). The addition of binahong leaf extract had an effect on color, but not on aroma, texture and taste. The best result was yoghurt synbiotic with addition of 0,12% binahong leaf extract. Conclusion of the research was the addition of binahong leaf extract to synbiotic yogurt did not significantly affect total LAB, antioxidant activity, aroma, texture and taste; but had a significant effect on color.
Šalomskienė, Joana; Abraitienė, Asta; Jonkuvienė, Dovilė; Mačionienė, Irena; Repečkienė, Jūratė
2015-07-01
The aim of the study was a detail evaluation of genetic diversity among the lactic acid bacteria (LAB) strains having an advantage of a starter culture in order to select genotypically diverse strains with enhanced antimicrobial effect on some harmfull and pathogenic microorganisms. Antimicrobial activity of LAB was performed by the agar well diffusion method and was examined against the reference strains and foodborne isolates of Bacillus cereus, Listeria monocytogenes, Escherichia coli, Staphylococcus aureus and Salmonella Typhimurium. Antifungal activity was tested against the foodborne isolates of Candida parapsilosis, Debaromyces hansenii, Kluyveromyces marxianus, Pichia guilliermondii, Yarowia lipolytica, Aspergillus brasiliensis, Aspergillus versicolor, Cladosporium herbarum, Penicillium chrysogenum and Scopulariopsis brevicaulis. A total 40 LAB strains representing Lactobacillus (23 strains), Lactococcus (13 strains) and Streptococcus spp. (4 strains) were characterised by repetitive sequence based polymerase chain reaction fingerprinting which generated highly discriminatory profiles, confirmed the identity and revealed high genotypic heterogeneity among the strains. Many of tested LAB demonstrated strong antimicrobial activity specialised against one or few indicator strains. Twelve LAB strains were superior in suppressing growth of the whole complex of pathogenic bacteria and fungi. These results demonstrated that separate taxonomic units offered different possibilities of selection for novel LAB strains could be used as starter cultures enhancing food preservation.
InstantLabs Listeria species food safety kit. Performance tested methods 041304.
Sharma, Neil; Bambusch, Lauren; Le, Thu; Morey, Amit
2014-01-01
The InstantLabs Listeria Species Food SafetyKitwas validated against the International Organization for Standardization (ISO) reference method 11290-1 for the detection of Listeria monocytogenes and other Listeria species. The matrixes (stainless steel, sealed concrete, cheddar cheese, raw shrimp, and hot dogs) were inoculated with approximately 1 CFU/test portion of various Listeria species to generate fractional positives (5-15) in 20 inoculated samples. Enrichments were also fractionally inoculated with L. monocytogenes for side-by-side testing of the InstantLabs Listeria monocytogenes Food Safety Kit. Stainless steel and sealed concrete samples were validated using 4 x 4" and 1 x 1" test areas, respectively, and enriched in Buffered Listeria Enrichment Broth (BLEB) at 35 +/- 1 degrees C for 22-28 h. All food samples were tested at 25 g or 25 mL and enriched in BLEB at 35 +/- 1 degrees C for 24-28 h. All samples were confirmed using the ISO reference method, regardless of initial screen result. The InstantLabs test method performed as well as or better than the reference method for the detection of Listeria species on stainless steel, sealed concrete, cheddar cheese, raw shrimp, and hot dogs. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 80 Listeria species and 30 non-Listeria species examined. The method was shown to be robust when variations were introduced to the enrichment time, the volume for DNA extraction, and the heat block time (data not shown).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Carl; Bohmann, Leonard; Naber, Jeffrey
2013-01-30
1) How the project adds to the education of engineering students in the area of vehicle electrification: This project created and implemented a significant interdisciplinary curriculum in HEV engineering that includes courses focused on the major components (engines, battery cells, e-machines, and power electronics). The new curriculum, rather uniquely, features two new classes and two new labs that emphasize a vehicle level integration of a hybrid electric powertrain that parallels the vehicle development process used by the OEMs - commercial grade software is used to design a hybrid electric vehicle, hardware-in-the-loop testing is performed on each component until the entiremore » powertrain is optimized, the calibration is flashed to a vehicle, ride-and-drives are executed including on board data acquisition. In addition, nine existing courses were modified by adding HEV material to the courses. 2) The educational effectiveness and economic feasibility of the new curriculum: The new courses are offered at both the undergraduate and graduate levels. They are listed across the college in mechanical, chemical, electrical, and materials science and engineering. They are offered both on campus and to distance learning students. Students across the college of engineering and at all degree levels are integrating these courses into their degree programs. Over the three year project the course enrollments on-campus has totaled 1,249. The distance learning enrollments has totaled 315. With such robust enrollments we absolutely expect that these courses will be in the curriculum for the long run. 3) How the project is otherwise of benefit to the public: One outcome of the project is the construction of the Michigan Tech Mobile Lab. Two complete HEV dynamometer test cells, and four work stations are installed in the 16.2 meter Mobile Laboratory and hauled by a class 8 truck. The Mobile Lab is used to teach the university courses. It is also used to deliver short courses to industry, K-12 outreach, and public education. In 2012 the Mobile Lab participated in 22 outreach events, locally, throughout Michigan, and including events in Washington DC, Illinois, and Wisconsin. The Mobile Lab is a hit wherever it goes. In 2013 we will partner with the US Army TARDEC and be featured in their Green Warrior Convoy, a ten city tour starting in Detroit and finishing in Washington DC.« less
Lab-on-a-Chip Application Development-Portable Test System (LOCAD) Phase 2
2009-03-21
ISS018-E-041370 (21 March 2009) --- Astronaut Sandra Magnus, STS-119 mission specialist, prepares to work with the Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) experiment in the Destiny laboratory while Space Shuttle Discovery remains docked with the International Space Station. LOCAD-PTS is a handheld device for rapid detection of biological and chemical substances onboard the station.
Di Lonardo, Maria Chiara; Binner, Erwin; Lombardi, Francesco
2015-09-01
In this study, the influence of an additional ripening process on the quality of mechanically-biologically treated MSW was evaluated in the prospective of recovering the end material, rather than landfilling. The biostabilised waste (BSW) coming from one of the MBT plants of Rome was therefore subjected to a ripening process in slightly aerated lab test cells. An in-depth investigation on the biological reactivity was performed by means of different types of tests (aerobic and anaerobic biological tests, as well as FT-IR spectroscopy method). A physical-chemical characterisation of waste samples progressively taken during the ripening phase was carried out, as well. In addition, the ripened BSW quality was assessed by comparing the characteristics of a compost sampled at the composting plant of Rome which treat source segregated organic wastes. Results showed that the additional ripening process allowed to obtain a better quality of the biostabilised waste, by achieving a much higher biological stability compared to BSW as-received and similar to that of the tested compost. An important finding was the lower heavy metals (Co, Cr, Cu, Ni, Pb and Zn) release in water phase at the end of the ripening compared to the as-received BSW, showing that metals were mainly bound to solid organic matter. As a result, the ripened waste, though not usable in agriculture as found for the compost sample, proved anyhow to be potentially suitable for land reclamation purposes, such as in landfills as cover material or mixed with degraded and contaminated soil for organic matter and nutrients supply and for metals recovery, respectively. In conclusion the study highlights the need to extend and optimise the biological treatment in the MBT facilities and opens the possibility to recover the output waste instead of landfilling. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Malik, A.; Setiawan, A.; Suhandi, A.; Permanasari, A.; Dirgantara, Y.; Yuniarti, H.; Sapriadil, S.; Hermita, N.
2018-01-01
This study aimed to investigate the improvement to pre-service teacher’s communication skills through Higher Order Thinking Laboratory (HOT Lab) on electric circuit topic. This research used the quasi-experiment method with pretest-posttest control group design. Research subjects were 60 students of Physics Education in UIN Sunan Gunung Djati Bandung. The sample was chosen by random sampling technique. Students’ communication skill data collected using a communication skills test instruments-essays form and observations sheets. The results showed that pre-service teacher communication skills using HOT Lab were higher than verification lab. Student’s communication skills in groups using HOT Lab were not influenced by gender. Communication skills could increase due to HOT Lab based on problems solving that can develop communication through hands-on activities. Therefore, the conclusion of this research shows the application of HOT Lab is more effective than the verification lab to improve communication skills of pre-service teachers in electric circuit topic and gender is not related to a person’s communication skills.
Probiotics versus antibiotic decontamination of the digestive tract: infection and mortality.
Oudhuis, Guy J; Bergmans, Dennis C; Dormans, Tom; Zwaveling, Jan-Harm; Kessels, Alfons; Prins, Martin H; Stobberingh, Ellen E; Verbon, Annelies
2011-01-01
Selective decontamination of the digestive tract (SDD) has been shown to decrease the infection rate and mortality in intensive care units (ICUs); Lactobacillus plantarum 299/299v plus fibre (LAB) has been used for infection prevention and does not harbour the potential disadvantages of antibiotics. The objective was to assess whether LAB is not inferior to SDD in infection prevention. Two hundred fifty-four consecutive ICU patients with expected mechanical ventilation ≥ 48 h and/or expected ICU stay ≥ 72 h were assigned to receive SDD: four times daily an oral paste (polymyxin E, gentamicin, amphotericin B), enteral solution (same antibiotics), intravenous cefotaxime (first 4 days) or LAB: two times daily L. plantarum 299/299v with rose-hip. The primary endpoint was infection rate. A difference <12% between both groups indicated non-inferiority of LAB. The trial was prematurely stopped after a study reporting increased mortality in critically ill pancreatitis patients receiving probiotics. No significant difference in infection rate [31% in the LAB group, 24% in the SDD group (OR 1.68, 95% CI 0.91-3.08; p = 0.10)] was found. ICU mortality was 26% and not significantly different between the LAB and SDD groups. Gram-positive cocci and Pseudomonas aeruginosa were significantly more frequently isolated from surveillance cultures in the SDD group compared to the LAB group (for sputum: 18 vs. 10% and 33 vs. 14%). Significantly more Enterobacteriaceae were found in the LAB group (23 vs. 50%). No increase in antibiotic resistance was found during and after SDD or LAB use. The trial could not demonstrate the non-inferiority of LAB compared with SDD in infection prevention. Results suggest no increased ICU mortality risk in the LAB group.
2016-11-25
CDC has released updated guidance online for U.S. laboratory testing for Zika virus infection. The guidance is available at https://www.cdc.gov/zika/laboratories/lab-guidance.html. Frequently asked questions are addressed at https://www.cdc.gov/zika/laboratories/lab-guidance-faq.html. This guidance updates recommendations for testing of specimens by U.S. laboratories for possible Zika virus infection. Major updates to the guidance with clinical implications for health care providers include the following.
Telerobotics test bed for space structure assembly
NASA Technical Reports Server (NTRS)
Kitami, M.; Ogimoto, K.; Yasumoto, F.; Katsuragawa, T.; Itoko, T.; Kurosaki, Y.; Hirai, S.; Machida, K.
1994-01-01
A cooperative research on super long distance space telerobotics is now in progress both in Japan and USA. In this program. several key features will be tested, which can be applicable to the control of space robots as well as to terrestrial robots. Local (control) and remote (work) sites will be shared between Electrotechnical Lab (ETL) of MITI in Japan and Jet Propulsion Lab (JPL) in USA. The details of a test bed for this international program are discussed in this report.
Liu, Wei; Tian, Jinping; Chen, Lujun; Guo, Yang
2017-01-01
An inventory of lead emissions was established for the lead-acid battery (LAB) manufacturing industry in China from 2000 to 2014. The lead emissions from the LAB manufacturing industry increased from 133 t in 2000 to a peak at 281 t in 2010 with the rapid development of LAB industry. Since 2011, a mandatory national clean action on LAB industry and a series of retrofitting measures have been implemented in China. As a result, more than 80% of small and low-efficient LAB manufacturers were closed, and technical-environmental performance of the industry has been improved significantly. Thus the lead emissions from the industry declined to 113 t in 2014. Geographically, lead emissions were attributed to several provinces with intensive LAB manufacturers, including Zhejiang, Guangdong, Jiangsu, Shandong, and Hebei Province. Spatial transfer of the LAB manufacturing industry from developed areas to developing areas in China was manifest due to strict environmental regulation, posing potential environmental risks to the areas undertaking the industry transfer. In light of the effectiveness of the national clean action, the LAB manufacturing industry will reduce lead emissions further by implementing the entry criteria strictly, adopting policy of total lead emissions control, and establishing a long-term regulatory mechanism for LAB manufacturers. The local authorities in some developing areas should improve abilities of environmental supervision and environmental risk prevention to deal with the spillover of lead emissions. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ao, Y.; Matsuda, Y.; Henkel, C.; Iono, D.; Alexander, D. M.; Chapman, S. C.; Geach, J.; Hatsukade, B.; Hayes, M.; Hine, N. K.; Kato, Y.; Kawabe, R.; Kohno, K.; Kubo, M.; Lehnert, M.; Malkan, M.; Menten, K. M.; Nagao, T.; Norris, R. P.; Ouchi, M.; Saito, T.; Tamura, Y.; Taniguchi, Y.; Umehata, H.; Weiss, A.
2017-12-01
We study the heating mechanisms and Lyα escape fractions of 35 Lyα blobs (LABs) at z ≈ 3.1 in the SSA22 field. Dust continuum sources have been identified in 11 of the 35 LABs, all with star formation rates (SFRs) above 100 M ⊙ yr-1. Likely radio counterparts are detected in 9 out of 29 investigated LABs. The detection of submillimeter dust emission is more linked to the physical size of the Lyα emission than to the Lyα luminosities of the LABs. A radio excess in the submillimeter/radio-detected LABs is common, hinting at the presence of active galactic nuclei. Most radio sources without X-ray counterparts are located at the centers of the LABs. However, all X-ray counterparts avoid the central regions. This may be explained by absorption due to exceptionally large column densities along the line-of-sight or by LAB morphologies, which are highly orientation dependent. The median Lyα escape fraction is about 3% among the submillimeter-detected LABs, which is lower than a lower limit of 11% for the submillimeter-undetected LABs. We suspect that the large difference is due to the high dust attenuation supported by the large SFRs, the dense large-scale environment as well as large uncertainties in the extinction corrections required to apply when interpreting optical data.
CSF total protein is a test to determine the amount of protein in your spinal fluid, also called cerebrospinal fluid (CSF). ... The normal protein range varies from lab to lab, but is typically about 15 to 60 milligrams per deciliter (mg/dL) ...
7. View of interior, EPA Farm Lab Building 1506 milk ...
7. View of interior, EPA Farm Lab Building 15-06 milk room, facing west - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV
6. View of interior, EPA Farm Lab Building 1506 milking ...
6. View of interior, EPA Farm Lab Building 15-06 milking area, facing northwest - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV
Santoni, Brandon; Cabezas, Andres F; Cook, Daniel J; Yeager, Matthew S; Billys, James B; Whiting, Benjamin; Cheng, Boyle C
2015-01-01
Pure-moment loading is the test method of choice for spinal implant evaluation. However, the apparatuses and boundary conditions employed by laboratories in performing spine flexibility testing vary. The purpose of this study was to quantify the differences, if they exist, in intervertebral range of motion (ROM) resulting from different pure-moment loading apparatuses used in two laboratories. Twenty-four (laboratory A) and forty-two (laboratory B) intact L1-S1 specimens were loaded using pure moments (±7.5 Nm) in flexion-extension (FE), lateral bending (LB) and axial torsion (AT). At laboratory A, pure moments were applied using a system of cables, pulleys and suspended weights in 1.5 Nm increments. At laboratory B, specimens were loaded in a pneumatic biaxial test frame mounted with counteracting stepper-motor-driven biaxial gimbals. ROM was obtained in both labs using identical optoelectronic systems and compared. In FE, total L1-L5 ROM was similar, on average, between the two laboratories (lab A: 37.4° ± 9.1°; lab B: 35.0° ± 8.9°, p=0.289). Larger apparent differences, on average, were noted between labs in AT (lab A: 19.4° ± 7.3°; lab B: 15.7° ± 7.1°, p=0.074), and this finding was significant for combined right and left LB (lab A: 45.5° ± 11.4°; lab B: 35.3° ± 8.5°, p < 0.001). To our knowledge, this is the first study comparing ROM of multi-segment lumbar spines between laboratories utilizing different apparatuses. The results of this study show that intervertebral ROM in multi-segment lumbar spine constructs are markedly similar in FE loading. Differences in boundary conditions are likely the source of small and sometimes statistically significant differences between the two techniques in LB and AT ROM. The relative merits of each testing strategy with regard to the physiologic conditions that are to be simulated should be considered in the design of a study including LB and AT modes of loading. An understanding of these differences also serves as important information when comparing study results across different laboratories.
Cohen-Bacrie, Stéphan; Ninove, Laetitia; Nougairède, Antoine; Charrel, Rémi; Richet, Hervé; Minodier, Philippe; Badiaga, Sékéné; Noël, Guilhem; La Scola, Bernard; de Lamballerie, Xavier; Drancourt, Michel; Raoult, Didier
2011-01-01
Background Clinical microbiology may direct decisions regarding hospitalization, isolation and anti-infective therapy, but it is not effective at the time of early care. Point-of-care (POC) tests have been developed for this purpose. Methods and Findings One pilot POC-lab was located close to the core laboratory and emergency ward to test the proof of concept. A second POC-lab was located inside the emergency ward of a distant hospital without a microbiology laboratory. Twenty-three molecular and immuno-detection tests, which were technically undemanding, were progressively implemented, with results obtained in less than four hours. From 2008 to 2010, 51,179 tests yielded 6,244 diagnoses. The second POC-lab detected contagious pathogens in 982 patients who benefited from targeted isolation measures, including those undertaken during the influenza outbreak. POC tests prevented unnecessary treatment of patients with non-streptococcal tonsillitis (n = 1,844) and pregnant women negative for Streptococcus agalactiae carriage (n = 763). The cerebrospinal fluid culture remained sterile in 50% of the 49 patients with bacterial meningitis, therefore antibiotic treatment was guided by the molecular tests performed in the POC-labs. With regard to enterovirus meningitis, the mean length-of-stay of infected patients over 15 years old significantly decreased from 2008 to 2010 compared with 2005 when the POC was not in place (1.43±1.09 versus 2.91±2.31 days; p = 0.0009). Altogether, patients who received POC tests were immediately discharged nearly thrice as often as patients who underwent a conventional diagnostic procedure. Conclusions The on-site POC-lab met physicians' needs and influenced the management of 8% of the patients that presented to emergency wards. This strategy might represent a major evolution of decision-making regarding the management of infectious diseases and patient care. PMID:21811599
NASA Astrophysics Data System (ADS)
Colla, C.; Gabrielli, E.
2017-01-01
To evaluate the complex behaviour of masonry structures under mechanical loads, numerical models are developed and continuously implemented at diverse scales, whilst, from an experimental viewpoint, laboratory standard mechanical tests are usually carried out by instrumenting the specimens via traditional measuring devices. Extracted values collected in the few points where the tools were installed are assumed to represent the behaviour of the whole specimen but this may be quite optimistic or approximate. Optical monitoring techniques may help in overcoming some of these limitations by providing full-field visualization of mechanical parameters. Photoelasticity and the more recent DIC, employed to monitor masonry columns during compression tests are here presented and a lab case study is compared listing procedures, data acquisitions, advantages and limitations. It is shown that the information recorded by traditional measuring tools must be considered limited to the specific instrumented points. Instead, DIC in particular among the optical techniques, is proving both a very precise global and local picture of the masonry performance, opening new horizons towards a deeper knowledge of this complex construction material. The applicability of an innovative DIC procedure to cultural heritage constructions is also discussed.
KAMIYA, Seitaro; OGASAWARA, Masayoshi; ARAKAWA, Masayuki; HAGIMORI, Masayori
2013-01-01
Thrombosis is characterized by congenital and acquired procatarxis. Lactic acid bacteria-fermented soybean milk products (FS-LAB) inhibit hepatic lipid accumulation and prevent atherosclerotic plaque formation. However, the therapeutic efficacy of FS-LAB against thrombosis has yet to be investigated. In this study, FS-LAB were administered subcutaneously into the tails of rats, with the subsequent intravenous administration of κ-carrageenan 12 hr after the initial injection. In general, administration of κ-carrageenan induces thrombosis. The length of the infarcted tail regions was significantly shorter in the rats administered a single-fold or double-fold concentration of the FS-LAB solution compared with the region in control rats. Therefore, FS-LAB exhibited significant antithrombotic effects. Our study is the first to characterize the properties of FS-LAB and, by testing their efficacy on an in vivo rat model of thrombosis, demonstrate the potency of their antithrombotic effect. PMID:24936368
Transforming the advanced lab: Part I - Learning goals
NASA Astrophysics Data System (ADS)
Zwickl, Benjamin; Finkelstein, Noah; Lewandowski, H. J.
2012-02-01
Within the physics education research community relatively little attention has been given to laboratory courses, especially at the upper-division undergraduate level. As part of transforming our senior-level Optics and Modern Physics Lab at the University of Colorado Boulder we are developing learning goals, revising curricula, and creating assessments. In this paper, we report on the establishment of our learning goals and a surrounding framework that have emerged from discussions with a wide variety of faculty, from a review of the literature on labs, and from identifying the goals of existing lab courses. Our goals go beyond those of specific physics content and apparatus, allowing instructors to personalize them to their contexts. We report on four broad themes and associated learning goals: Modeling (math-physics-data connection, statistical error analysis, systematic error, modeling of engineered "black boxes"), Design (of experiments, apparatus, programs, troubleshooting), Communication, and Technical Lab Skills (computer-aided data analysis, LabVIEW, test and measurement equipment).
NASA Astrophysics Data System (ADS)
Corni, Federico; Fuchs, Hans U.; Savino, Giovanni
2018-02-01
This is a description of the conceptual foundations used for designing a novel learning environment for mechanics implemented as an Industrial Educational Laboratory - called Fisica in Moto (FiM) - at the Ducati Foundation in Bologna. In this paper, we will describe the motivation for and design of the conceptual approach to mechanics used in the lab - as such, the paper is theoretical in nature. The goal of FiM is to provide an approach to the teaching of mechanics based upon imaginative structures found in continuum physics suitable to engineering and science. We show how continuum physics creates models of mechanical phenomena by using momentum and angular momentum as primitive quantities. We analyse this approach in terms of cognitive linguistic concepts such as conceptual metaphor and narrative framing of macroscopic physical phenomena. The model discussed here has been used in the didactical design of the actual lab and raises questions for an investigation of student learning of mechanics in a narrative setting.
Mechanisms of Bacterial Spore Germination and Its Heterogeneity
2015-01-10
mathematical model describing spore germination has been developed; 9) much of the work above has been extended to Clostridium spores; and 10) ~90...germination. C) Faeder lab, with Li and Setlow labs. We have developed a mathematical model of bacterial spore germination that accounts for...heterogeneity in both Tlag and commitment times. The model is built from three main mathematical components: a receptor distribution function
Report to Lincoln Labs on TWPAs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dubois, J.; Carosi, G.; Woollett, N.
2017-09-26
This past spring LLNL’s Quantum Sensor’s team received two TWPA amplifiers from Lincoln Labs along with a data-sheet explaining handling, operations and expected performance. Here we will outline some of the initial tests performed on this amplifiers as part of LLNL’s Quantum Sensors Strategic Initiative (QSSI). Initial testing confirmed that both amplifiers worked and provided gain and SNR improvement similar to that called out in the data-sheets provided.
Gerotziafas, Grigoris T; Ray, Patrick; Gkalea, Vasiliki; Benzarti, Ahlem; Khaterchi, Amir; Cast, Claire; Pernet, Julie; Lefkou, Eleftheria; Elalamy, Ismail
2016-12-01
Easy to use point of care assays for D-Dimers measurement in whole blood from patients with clinical suspicion of venous thromboembolism (VTE) will facilitate the diagnostic strategy in the Emergency Department (ED) setting. We prospectively evaluated the diagnostic performance of the point-of-care mLabs® Whole Blood D-Dimers test and we compared it with the Vidas® D-Dimers assay. As part of the diagnostic algorithm applied in patients with clinical suspicion of VTE, the VIDAS® D-Dimers Test was prescribed by the emergency physician in charge. The mLabs® Whole Blood D-Dimers Test was used on the same samples. All patients had undergone exploration with the recommended imaging techniques for VTE diagnosis. Both assays were performed, on 99 emergency patients (mean age was 65 years) with clinical suspicion of VTE. In 3% of patients, VTE was documented with a reference imaging technique. The Bland and Altman test showed significant agreement between the two methods. Both assays showed equal sensitivity and negative predictive value for VTE. The mLabs whole blood assay is a promising point of care method for measurement of D-Dimers and exclusion of VTE diagnosis in the emergency setting which should be validated in a larger prospective study.
Wang, Qin; Zhang, Yong; Nie, Kai; Wang, Huanyu; Du, Haijun; Song, Jingdong; Xiao, Kang; Lei, Wenwen; Guo, Jianqiang; Wei, Hejiang; Cai, Kun; Wang, Yanhai; Wu, Jiang; Gerald, Bangura; Kamara, Idrissa Laybohr; Liang, Mifang; Wu, Guizhen; Dong, Xiaoping
2016-03-01
The quality control process throughout the Ebola virus nucleic acid detection in Sierra Leone-China Friendship Biological Safety Laboratory (SLE-CHN Biosafety Lab) was described in detail, in order to comprehensively display the scientific, rigorous, accurate and efficient practice in detection of Ebola virus of first batch detection team in SLE-CHN Biosafety Lab. Firstly, the key points of laboratory quality control system was described, including the managements and organizing, quality control documents and information management, instrument, reagents and supplies, assessment, facilities design and space allocation, laboratory maintenance and biosecurity. Secondly, the application of quality control methods in the whole process of the Ebola virus detection, including before the test, during the test and after the test, was analyzed. The excellent and professional laboratory staffs, the implementation of humanized management are the cornerstone of the success; High-level biological safety protection is the premise for effective quality control and completion of Ebola virus detection tasks. And professional logistics is prerequisite for launching the laboratory diagnosis of Ebola virus. The establishment and running of SLE-CHN Biosafety Lab has landmark significance for the friendship between Sierra Leone and China, and the lab becomes the most important base for Ebola virus laboratory testing in Sierra Leone.
Pal, Reshmi; Mendelson, John; Clavier, Odile; Baggott, Mathew J; Coyle, Jeremy; Galloway, Gantt P
2016-01-01
In methamphetamine (MA) users, drug-induced neurocognitive deficits may help to determine treatment, monitor adherence, and predict relapse. To measure these relationships, we developed an iPhone app (Neurophone) to compare lab and field performance of N-Back, Stop Signal, and Stroop tasks that are sensitive to MA-induced deficits. Twenty healthy controls and 16 MA-dependent participants performed the tasks in-lab using a validated computerized platform and the Neurophone before taking the latter home and performing the tasks twice daily for two weeks. N-Back task: there were no clear differences in performance between computer-based vs. phone-based in-lab tests and phone-based in-lab vs. phone-based in-field tests. Stop-Signal task: difference in parameters prevented comparison of computer-based and phone-based versions. There was significant difference in phone performance between field and lab. Stroop task: response time measured by the speech recognition engine lacked precision to yield quantifiable results. There was no learning effect over time. On an average, each participant completed 84.3% of the in-field NBack tasks and 90.4% of the in-field Stop Signal tasks (MA-dependent participants: 74.8% and 84.3%; healthy controls: 91.4% and 95.0%, respectively). Participants rated Neurophone easy to use. Cognitive tasks performed in-field using Neurophone have the potential to yield results comparable to those obtained in a laboratory setting. Tasks need to be modified for use as the app's voice recognition system is not yet adequate for timed tests.
Blodgett, Joanna M; Theou, Olga; Howlett, Susan E; Wu, Frederick C W; Rockwood, Kenneth
2016-07-01
abnormal laboratory test results accumulate with age and can be common in people with few clinically detectable health deficits. A frailty index (FI) based entirely on common physiological and laboratory tests (FI-Lab) might offer pragmatic and scientific advantages compared with a clinical FI (FI-Clin). to compare the FI-Lab with the FI-Clin and to assess their individual and combined relationships with mortality and other adverse health outcomes. secondary analysis of the eight-centre, longitudinal European Male Ageing Study (EMAS) of community-dwelling men aged 40-79 at baseline. Follow-up assessment occurred 4.4 ± 0.3 (mean ± SD) years later. we constructed a 23-item FI using common laboratory tests, blood pressure and pulse (FI-Lab), compared it with a previously validated 39-item FI using self-report and performance-based measures (FI-Clin) and finally combined both FIs to create a 62-item FI-Combined. Outcomes were all-cause mortality, institutionalisation, doctor visits, medication use, self-reported health, falls and fractures. the mean FI-Lab score was 0.28 ± 0.11, the FI-Clin was 0.13 ± 0.11 and FI-Combined was 0.19 ± 0.09. Age-adjusted models demonstrated that each FI was associated with mortality [HR (CI) FI-Lab: 1.04 (1.03-1.06); FI-Clin: 1.05 (1.04-1.06); FI-Combined: 1.07 (1.06-1.09)], institutionalisation, doctor visits, medication use, self-reported health and falls. Combined in a model with FI-Clin, the FI-Lab remained independently associated with mortality, institutionalisation, doctor visits, medication use and self-reported health. the FI-Lab detected an increased risk of adverse health outcomes alone and in combination with a clinical FI; further evaluation of the feasibility of the FI-Lab as a frailty screening tool within hospital care settings is needed. © The Author 2016. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Optical sensors for electrical elements of a medium voltage distribution network
NASA Astrophysics Data System (ADS)
De Maria, Letizia; Bartalesi, Daniele; Serragli, Paolo; Paladino, Domenico
2012-04-01
The aging of most of the components of the National transmission and distribution system can potentially influence the reliability of power supply in a Medium Voltage (MV) network. In order to prevent possible dangerous situations, selected diagnostic indicators on electrical parts exploiting reliable and potentially low-cost sensors are required. This paper presents results concerning two main research activities regarding the development and application of innovative optical sensors for the diagnostic of MV electrical components. The first concerns a multi-sensor prototype for the detection of pre-discharges in MV switchboards: it is the combination of three different types of sensors operating simultaneously to detect incipient failure and to reduce the occurrence of false alarms. The system is real-time controlled by an embedded computer through a LabView interface. The second activity refers to a diagnostic tool to provide significant real-time information about early aging of MV/Low Voltage (LV) transformers by means of its vibration fingerprint. A miniaturized Optical Micro-Electro-Mechanical System (MEMS) based unit has been assembled for vibration measurements, wireless connected to a remote computer and controlled via LabView interface. Preliminary comparative tests were carried out with standard piezoelectric accelerometers on a conventional MV/LV test transformer under open circuit and in short-circuited configuration.
Dess, Nancy K; Madkins, Chardonnay D; Geary, Bree A; Chapman, Clinton D
2013-11-21
Naïve humans and rats voluntarily consume little ethanol at concentrations above ~6% due to its aversive flavor. Developing procedures that boost intake of ethanol or ethanol-paired flavors facilitates research on neural mechanisms of ethanol-associated behaviors and helps identify variables that modulate ethanol intake outside of the lab. The present study explored the impact on consumption of ethanol and ethanol-paired flavors of nutritionally significant parametric variations: ethanol vehicle (gelatin or solution, with or without polycose); ethanol concentration (4% or 10%); and feeding status (chow deprived or ad lib.) during flavor conditioning and flavor preference testing. Individual differences were modeled by testing rats of lines selectively bred for high (HiS) or low (LoS) saccharin intake. A previously reported preference for ethanol-paired flavors was replicated when ethanol had been drunk during conditioning. However, indifference or aversion to ethanol-paired flavors generally obtained when ethanol had been eaten in gelatin during conditioning, regardless of ethanol concentration, feeding status, or caloric value of the vehicle. Modest sex and line variations occurred. Engaging different behavioral systems when eating gelatin, rather than drinking solution, may account for these findings. Implications for parameter selection in future neurobiological research and for understanding conditions that influence ethanol intake outside of the lab are discussed.
Fuel-Flexible Gasification-Combustion Technology for Production of H2 and Sequestration-Ready CO2
DOE Office of Scientific and Technical Information (OSTI.GOV)
George Rizeq; Janice West; Raul Subia
GE Global Research is developing an innovative energy technology for coal gasification with high efficiency and near-zero pollution. This Unmixed Fuel Processor (UFP) technology simultaneously converts coal, steam and air into three separate streams of hydrogen-rich gas, sequestration-ready CO{sub 2}, and high-temperature, high-pressure vitiated air to produce electricity in gas turbines. This is the draft final report for the first stage of the DOE-funded Vision 21 program. The UFP technology development program encompassed lab-, bench- and pilot-scale studies to demonstrate the UFP concept. Modeling and economic assessments were also key parts of this program. The chemical and mechanical feasibility weremore » established via lab and bench-scale testing, and a pilot plant was designed, constructed and operated, demonstrating the major UFP features. Experimental and preliminary modeling results showed that 80% H{sub 2} purity could be achieved, and that a UFP-based energy plant is projected to meet DOE efficiency targets. Future work will include additional pilot plant testing to optimize performance and reduce environmental, operability and combined cycle integration risks. Results obtained to date have confirmed that this technology has the potential to economically meet future efficiency and environmental performance goals.« less
NASA Photographer Prepares to Film a Mercury Capsule
1959-06-21
National Aeronautics and Space Administration (NASA) photographer Arthur Laufman sets up a camera to film a Mercury capsule that was constructed by the Lewis Research Center staff. Lewis engineers and mechanics built two of the capsules for the upcoming Big Joe launches in September 1959. Big Joe was an attempt early in Project Mercury to use a full-scale Atlas booster to simulate the reentry of a mock-up Mercury capsule without actually placing it in orbit. The Photographic Branch, referred to as the Photo Lab, was part of the center’s Technical Reports Division. Originally the group performed normal and high-speed still image and motion picture photography. The photographers documented construction, performed publicity work, created images for reports, photographed data on manometer boards, and recorded test footage. Laufman joined the Photo Lab staff in 1948 and began producing full-length technical films as a tool to educate those outside of the agency on the research being conducted at Lewis. He worked with engineers to determine proper subjects for these films and develop a script. Laufman not only filmed tests, but also supporting footage of facilities, models, and staff members. He then edited the footage and added audio, visuals, and narration. The film masters were assigned standard identification numbers and add to the Photo Lab’s catalogue.
Selected KSC Applied Physics Lab Responses to Shuttle Processing Measurement Requests
NASA Technical Reports Server (NTRS)
Youngquist, Robert C.
2010-01-01
The KSC Applied Physics Lab has been supporting Shuttle Ground Processing for over 20 years by solving problems brought to us by Shuttle personnel. Roughly half of the requests to our lab have been to find ways to make measurements, or to improve on an existing measurement process. This talk will briefly cover: 1) Centering the aft end of the External Tank between the Solid Rocket Boosters; 2) Positioning the GOX Vent Hood over the External Tank; 3) Remote Measurements of External Tank Damage; 4) Strain Measurement in the Orbiter Sling; and 5) Over-center Distance Measurement in an Over-center Mechanism.
Features of πΔ photoproduction at high energies
Nys, Jannes; Mathieu, V.; Fernandez-Ramirez, C.; ...
2018-02-02
Hybrid/exotic meson spectroscopy searches at Jefferson Lab require the accurate theoretical description of the production mechanism in peripheral photoproduction. We develop a model for πΔ photoproduction at high energies (5 ≤ E lab ≤ 16 GeV) that incorporates both the absorbed pion and natural-parity cut contributions. We fit the available observables, providing a good description of the energy and angular dependencies of the experimental data. In conclusion, we also provide predictions for the photon beam asymmetry of charged pions at E lab = 9 GeV which is expected to be measured by GlueX and CLAS12 experiments in the near future.
Features of πΔ photoproduction at high energies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nys, Jannes; Mathieu, V.; Fernandez-Ramirez, C.
Hybrid/exotic meson spectroscopy searches at Jefferson Lab require the accurate theoretical description of the production mechanism in peripheral photoproduction. We develop a model for πΔ photoproduction at high energies (5 ≤ E lab ≤ 16 GeV) that incorporates both the absorbed pion and natural-parity cut contributions. We fit the available observables, providing a good description of the energy and angular dependencies of the experimental data. In conclusion, we also provide predictions for the photon beam asymmetry of charged pions at E lab = 9 GeV which is expected to be measured by GlueX and CLAS12 experiments in the near future.
USDA-ARS?s Scientific Manuscript database
Lactic acid bacteria (LAB) frequently contaminate commercial fuel ethanol fermentations, reducing yields and decreasing profitability of biofuel production. Microorganisms from environmental sources in different geographic regions of Thailand were tested for antibacterial activity against LAB. Fou...
2. Oblique view of EPA Farm Lab Building 1506 (with ...
2. Oblique view of EPA Farm Lab Building 15-06 (with slaughter addition at far left), facing southwest - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV
NASA Astrophysics Data System (ADS)
Zuckerman, Nathaniel Benjamin
1. Compound NSC-670224, previously shown to be toxic to Saccharomyces cerevisiae at low micromolar concentrations, potentially acts via a mechanism of action related to that of tamoxifen (NSC 180973), a widely utilized breast cancer drug. The structure of NSC-670224, previously thought to be a 2,4-dichloro arene, was established as the 3,4-dichloro arene, and a focused library of analogues were synthesized and biologically evaluated in conjunction with the UCSC Chemical Screening Center. The synthesis of a biotinylated affinity probe was also completed in order to extract the protein target(s) of NSC-670224 from yeast and human cell lines in collaboration with the Hartzog lab (UCSC MCD Biology) 2. Stabilization of ruthenium nanoparticles (Ru NPs) through carbene bound ligands has led to a simple and effective means to generate new materials with unique optoelectronic properties. The affinity of freshly prepared Ru NPs to diazo compounds, specifically octyl diazoacetate (ODA), provides a robust nanostructure that can be further functionalized via metathesis of terminal olefins to generate these unique materials. Carbene-stabilized Ru NPs have provided insights into the nature of extended conjugation and intraparticle charge delocalization through covalently bound probes (e.g., ferrocene and pyrene). The growing interest to study electronic communication through Ru NPs has lead to collaborative, multidisciplinary efforts between analytical (Shaowei Chen lab, UCSC), theoretical (Haobin Wang Lab, NMSU), and synthetic organic chemists (Konopelski Lab, UCSC). With this powerful collaboration, new methods to generate stabilized Ru NPs, testing theory with experiment, and efficient means to functionalize NPs have been investigated. The syntheses of custom ligands and their applications to nanoparticle-mediated electronic communication are reported.
A composite thin vacuum window for the CLAS photon tagger at Jefferson lab
NASA Astrophysics Data System (ADS)
Matthews, S. K.; Crannell, Hall; O'Brien, J. T.; Sober, D. I.
1999-01-01
The construction of a thin vacuum window, currently in use on the CLAS photon tagging system at the Thomas Jefferson National Accelerator Facility, is described. A layer of woven Kevlar cloth supports a much thinner membrane of aluminized Mylar. Notable features of this particular window include its overall length (9.6 m), and the fact that the entire load is supported by the epoxy seal with no mechanical clamping around the edges. Results from a diverse program of materials testing, including a clear dependence of leak rate on relative humidity, are also reported.
An update on Lab Rover: A hospital material transporter
NASA Technical Reports Server (NTRS)
Mattaboni, Paul
1994-01-01
The development of a hospital material transporter, 'Lab Rover', is described. Conventional material transport now utilizes people power, push carts, pneumatic tubes and tracked vehicles. Hospitals are faced with enormous pressure to reduce operating costs. Cyberotics, Inc. developed an Autonomous Intelligent Vehicle (AIV). This battery operated service robot was designed specifically for health care institutions. Applications for the AIV include distribution of clinical lab samples, pharmacy drugs, administrative records, x-ray distribution, meal tray delivery, and certain emergency room applications. The first AIV was installed at Lahey Clinic in Burlington, Mass. Lab Rover was beta tested for one year and has been 'on line' for an additional 2 years.
From e-manufacturing to Internet Product Process Development (IPPD) through remote - labs
NASA Astrophysics Data System (ADS)
Córdoba Nieto, Ernesto; Andres Cifuentes Parra, Paulo; Camilo Parra Díaz, Juan
2014-07-01
This paper presents the research developed at Universidad Nacional de Colombia about the e-Manufacturing platform that is being developed and implemented at LabFabEx (acronym in Spanish as "Laboratorio Fabrica Experimental"). This platform besides has an approach to virtual-remote labs that have been tested by several students and engineers of different industrial fields. At this paper it is shown the physical and communication experimental platform, the general scope and characteristics of this e-Manufacturing platform and the virtual lab approach. This research project is funded by COLCIENCIAS (Administrative Department of science, technology and innovation in Colombia) and the enterprise IMOCOM S.A.
Engineering of a miniaturized, robotic clinical laboratory
Nourse, Marilyn B.; Engel, Kate; Anekal, Samartha G.; Bailey, Jocelyn A.; Bhatta, Pradeep; Bhave, Devayani P.; Chandrasekaran, Shekar; Chen, Yutao; Chow, Steven; Das, Ushati; Galil, Erez; Gong, Xinwei; Gessert, Steven F.; Ha, Kevin D.; Hu, Ran; Hyland, Laura; Jammalamadaka, Arvind; Jayasurya, Karthik; Kemp, Timothy M.; Kim, Andrew N.; Lee, Lucie S.; Liu, Yang Lily; Nguyen, Alphonso; O'Leary, Jared; Pangarkar, Chinmay H.; Patel, Paul J.; Quon, Ken; Ramachandran, Pradeep L.; Rappaport, Amy R.; Roy, Joy; Sapida, Jerald F.; Sergeev, Nikolay V.; Shee, Chandan; Shenoy, Renuka; Sivaraman, Sharada; Sosa‐Padilla, Bernardo; Tran, Lorraine; Trent, Amanda; Waggoner, Thomas C.; Wodziak, Dariusz; Yuan, Amy; Zhao, Peter; Holmes, Elizabeth A.
2018-01-01
Abstract The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay‐configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay‐specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti‐herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration‐cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations. PMID:29376134
The U.S. Lab placed in vacuum chamber for leak test
NASA Technical Reports Server (NTRS)
2000-01-01
In the Operations and Checkout Building, the U.S. Lab, a component of the International Space Station, is lowered into a three-story vacuum chamber. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber for a leak test. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research.
Engineering of a miniaturized, robotic clinical laboratory.
Nourse, Marilyn B; Engel, Kate; Anekal, Samartha G; Bailey, Jocelyn A; Bhatta, Pradeep; Bhave, Devayani P; Chandrasekaran, Shekar; Chen, Yutao; Chow, Steven; Das, Ushati; Galil, Erez; Gong, Xinwei; Gessert, Steven F; Ha, Kevin D; Hu, Ran; Hyland, Laura; Jammalamadaka, Arvind; Jayasurya, Karthik; Kemp, Timothy M; Kim, Andrew N; Lee, Lucie S; Liu, Yang Lily; Nguyen, Alphonso; O'Leary, Jared; Pangarkar, Chinmay H; Patel, Paul J; Quon, Ken; Ramachandran, Pradeep L; Rappaport, Amy R; Roy, Joy; Sapida, Jerald F; Sergeev, Nikolay V; Shee, Chandan; Shenoy, Renuka; Sivaraman, Sharada; Sosa-Padilla, Bernardo; Tran, Lorraine; Trent, Amanda; Waggoner, Thomas C; Wodziak, Dariusz; Yuan, Amy; Zhao, Peter; Young, Daniel L; Robertson, Channing R; Holmes, Elizabeth A
2018-01-01
The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay-configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay-specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti-herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration-cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations.
... Mumps Tests MPV Blood Test Mucus in Urine N Nitrites in Urine P Pap Smear Porphyrin Test ... V Vitamin D Test Vitamin E (tocopherol) Test Y Yeast Infection Test Related MedlinePlus Health Topics Laboratory ...
NASA Astrophysics Data System (ADS)
Brinson, James R.
The current study compared the effects of virtual versus physical laboratory manipulatives on 84 undergraduate non-science majors' (a) conceptual understanding of density and (b) density-related inquiry skill acquisition. A pre-post comparison study design was used, which incorporated all components of an inquiry-guided classroom, except experimental mode, and which controlled for curriculum, instructor, instructional method, time spent on task, and availability of reference resources. Participants were randomly assigned to either a physical or virtual lab group. Pre- and post-assessments of conceptual understanding and inquiry skills were administered to both groups. Paired-samples t tests revealed a significant mean percent correct score increase for conceptual understanding in both the physical lab group (M = .103, SD = .168), t(38) = -3.82, p < .001, r = .53, two-tailed, and the virtual lab group (M = .084, SD = .177), t(44) = -3.20, p = .003, r = .43, two-tailed. However, a one-way ANCOVA (using pretest scores as the covariate) revealed that the main effect of lab group on conceptual learning gains was not significant, F(1, 81) = 0.081, p = .776, two-tailed. An omnibus test of model coefficients within hierarchical logistic regression revealed that a correct response on inquiry pretest scores was not a significant predictor of a correct post-test response, chi 2(1, N = 84) = 1.68, p = .195, and that when lab mode was added to the model, it did not significantly increase the model's predictive ability, chi2(2, N = 84) = 1.95, p = .377. Thus, the data in the current study revealed no significant difference in the effect of physical versus virtual manipulatives when used to teach conceptual understanding and inquiry skills related to density.
3D Animations for Exploring Nucleon Structure
NASA Astrophysics Data System (ADS)
Gorman, Waverly; Burkardt, Matthias
2016-09-01
Over the last few years many intuitive pictures have been developed for the interpretation of electron hadron scattering experiments, such as a mechanism for transverse single-spin asymmetries in semi-inclusive deep-inelastic scattering experiments. While Dr. Burkardt's pictures have been helpful for many researchers in the field, they are still difficult to visualize for broader audiences since they rely mostly on 2-dimensional static images. In order to make more accessible for a broader audience what can be learned from Jefferson Lab experiments, we have started to work on developing 3-dimensional animations for these processes. The goal is to enable the viewer to repeatedly look at the same microscopic mechanism for a specific reaction, with the viewpoint of the observer changing. This should help an audience that is not so familiar with these reactions to better understand what can be learned from various experiments at Jefferson Lab aimed at exploring the nucleon structure. Jefferson Lab Minority/Female Undergraduate Research Assistantship.
NASA Astrophysics Data System (ADS)
Micari, Marina; Pazos, Pilar; Hartmann, Mitra J. Z.
Although there has been a great deal of research on women's experiences in engineering study, there has been little attempt to connect experiential factors to performance in both course and lab. This two-phase study investigated gender differences in undergraduates' experiences in a fluid mechanics course as well as the relationship between experiential factors and student performance in that course. One hundred forty-seven students at a Midwestern research university completed questionnaires related to course experience and perceived engagement. Data were also collected on final grade for 89 students in the second round of data collection. Relative to men, women reported less confidence that they could avoid mistakes in the lab, less experience with mechanical items, less perceived ability in engineering relative to classmates, and less perceived skill in tasks requiring navigation or maneuvering through space. Feelings of engagement were related to grade, but no gender differences were found in either engagement or grade.
Development and design of a late-model fitness test instrument based on LabView
NASA Astrophysics Data System (ADS)
Xie, Ying; Wu, Feiqing
2010-12-01
Undergraduates are pioneers of China's modernization program and undertake the historic mission of rejuvenating our nation in the 21st century, whose physical fitness is vital. A smart fitness test system can well help them understand their fitness and health conditions, thus they can choose more suitable approaches and make practical plans for exercising according to their own situation. following the future trends, a Late-model fitness test Instrument based on LabView has been designed to remedy defects of today's instruments. The system hardware consists of fives types of sensors with their peripheral circuits, an acquisition card of NI USB-6251 and a computer, while the system software, on the basis of LabView, includes modules of user register, data acquisition, data process and display, and data storage. The system, featured by modularization and an open structure, is able to be revised according to actual needs. Tests results have verified the system's stability and reliability.
Caruso, Joseph P; Israel, Natalie; Rowland, Kimberly; Lovelace, Matthew J; Saunders, Mary Jane
2016-03-01
Course-based undergraduate research is known to improve science, technology, engineering, and mathematics student achievement. We tested "The Small World Initiative, a Citizen-Science Project to Crowdsource Novel Antibiotic Discovery" to see if it also improved student performance and the critical thinking of non-science majors in Introductory Biology at Florida Atlantic University (a large, public, minority-dominant institution) in academic year 2014-15. California Critical Thinking Skills Test pre- and posttests were offered to both Small World Initiative (SWI) and control lab students for formative amounts of extra credit. SWI lab students earned significantly higher lecture grades than control lab students, had significantly fewer lecture grades of D+ or lower, and had significantly higher critical thinking posttest total scores than control students. Lastly, more SWI students were engaged while taking critical thinking tests. These results support the hypothesis that utilizing independent course-based undergraduate science research improves student achievement even in nonscience students.
King, Thomas L; Clyburne, Jason A C; Lee, Kenneth; Robinson, Brian J
2013-06-15
Test facilities such as lab basins and wave tanks are essential when evaluating the use of chemical dispersants to treat oil spills at sea. However, these test facilities have boundaries (walls) that provide an ideal environment for surface (interfacial) film formation on seawater. Surface films may form from surfactants naturally present in crude oil as well as dispersant drift/overspray when applied to an oil spill. The objective of this study was to examine the impact of surface film formation on oil spreading rates in a small scale lab basin and on dispersant effectiveness conducted in a large scale wave tank. The process of crude oil spreading on the surface of the basin seawater was influenced in the presence of a surface film as shown using a 1st order kinetic model. In addition, interfacial film formation can greatly influence chemically dispersed crude oil in a large scale dynamic wave tank. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Kilaru, Varun; Barfield, Richard T; Schroeder, James W; Smith, Alicia K
2012-01-01
Recent evidence suggests that DNA methylation changes may underlie numerous complex traits and diseases. The advent of commercial, array-based methods to interrogate DNA methylation has led to a profusion of epigenetic studies in the literature. Array-based methods, such as the popular Illumina GoldenGate and Infinium platforms, estimate the proportion of DNA methylated at single-base resolution for thousands of CpG sites across the genome. These arrays generate enormous amounts of data, but few software resources exist for efficient and flexible analysis of these data. We developed a software package called MethLAB (http://genetics.emory.edu/conneely/MethLAB) using R, an open source statistical language that can be edited to suit the needs of the user. MethLAB features a graphical user interface (GUI) with a menu-driven format designed to efficiently read in and manipulate array-based methylation data in a user-friendly manner. MethLAB tests for association between methylation and relevant phenotypes by fitting a separate linear model for each CpG site. These models can incorporate both continuous and categorical phenotypes and covariates, as well as fixed or random batch or chip effects. MethLAB accounts for multiple testing by controlling the false discovery rate (FDR) at a user-specified level. Standard output includes a spreadsheet-ready text file and an array of publication-quality figures. Considering the growing interest in and availability of DNA methylation data, there is a great need for user-friendly open source analytical tools. With MethLAB, we present a timely resource that will allow users with no programming experience to implement flexible and powerful analyses of DNA methylation data. PMID:22430798
Makransky, Guido; Thisgaard, Malene Warming; Gadegaard, Helen
2016-01-01
To investigate if a virtual laboratory simulation (vLAB) could be used to replace a face to face tutorial (demonstration) to prepare students for a laboratory exercise in microbiology. A total of 189 students who were participating in an undergraduate biology course were randomly selected into a vLAB or demonstration condition. In the vLAB condition students could use a vLAB at home to 'practice' streaking out bacteria on agar plates in a virtual environment. In the demonstration condition students were given a live demonstration from a lab tutor showing them how to streak out bacteria on agar plates. All students were blindly assessed on their ability to perform the streaking technique in the physical lab, and were administered a pre and post-test to determine their knowledge of microbiology, intrinsic motivation to study microbiology, and self-efficacy in the field of microbiology prior to, and after the experiment. The results showed that there were no significant differences between the two groups on their lab scores, and both groups had similar increases in knowledge of microbiology, intrinsic motivation to study microbiology, as well as self-efficacy in the field of microbiology. Our data show that vLABs function just as well as face to face tutorials in preparing students for a physical lab activity in microbiology. The results imply that vLABs could be used instead of face to face tutorials, and a combination of virtual and physical lab exercises could be the future of science education.
NASA Astrophysics Data System (ADS)
Yang, F.; Dong, Z. H.; Ye, X.
2018-05-01
Currently, space robots have been become a very important means of space on-orbit maintenance and support. Many countries are taking deep research and experiment on this. Because space operation attitude is very complicated, it is difficult to model them in research lab. This paper builds up a complete equivalent experiment framework according to the requirement of proposed space soft-contact technology. Also, this paper carries out flexible multi-body dynamics parameters verification for on-orbit soft-contact mechanism, which combines on-orbit experiment data, the built soft-contact mechanism equivalent model and flexible multi-body dynamics equivalent model that is based on KANE equation. The experiment results approve the correctness of the built on-orbit soft-contact flexible multi-body dynamics.
Designing a ruggedisation lab to characterise materials for harsh environments.
Frazzette, Nicholas; Jethva, Janak; Mehta, Khanjan; Stapleton, Joshua J; Randall, Clive
Designing products for use in developing countries presents a unique set of challenges including harsh operating environments, costly repairs and maintenance, and users with varying degrees of education and device familiarity. For products to be robust, adaptable and durable, they need to be ruggedised for environmental factors such as high temperature and humidity as well as different operational conditions such as shock and chemical exposure. The product characterisation and ruggedisation processes require specific expertise and resources that are seldom available outside of large corporations and elite national research labs. There is no standardised process since product needs strongly depend on the context and user base, making it particularly onerous for underfunded start-ups and academic groups. Standardised protocols that identify essential lab testing regimens for specific contexts and user groups can complement field-testing and accelerate the product development process while reducing costs. This article synthesises current methods and strategies for product testing employed by large corporations as well as defence-related entities. A technological and organisational framework for a service-for-fee product characterisation and ruggedisation lab that reduces costs and shortens the timespan from product invention to commercial launch in harsh settings is presented.
Using soil test results to determine fertilizer applications
C. B. Davey
2002-01-01
Using soil test results is a very useful practice IF the sample(s) of soil are good representations of the nursery soil. The lab results can be no more accurate than the samples submitted, and IF you know the texture of the nursery soil, and IF you know which soil extractant was used by the lab, and IF you know what crop is to be grown, and IF, for trees, which species...
Geolab Results from Three Years of Analog Mission Tests
NASA Technical Reports Server (NTRS)
Evans, Cindy A.; Bell, M. S.; Calaway, M. J.
2013-01-01
GeoLab is a prototype glovebox for geological sample examination that was, until November 2012, fully integrated into NASA's Deep Space Habitat Analog Testbed [1,2]. GeoLab allowed us to test science operations related to contained sample examination during simulated exploration missions. The facility, shown in Figure 1 and described elsewhere [1-4], was designed for fostering the development of both instrument technology and operational concepts for sample handling and examination during future missions [3-5]. Even though we recently deintegrated the glovebox from the Deep Space Habitat (Fig. 2), it continues to provide a high-fidelity workspace for testing instruments that could be used for sample characterization. As a testbed, GeoLab supports the development of future science operations that will enhance the early scientific returns from exploration missions, and will help ensure selection of the best samples for Earth return.
Update on SPLAT and cranberry fruitworm degree-days
USDA-ARS?s Scientific Manuscript database
This talk reviews the mating disruption mechanism and work that we have done in the Steffan lab summers 2012-2014. In 2016 we mechanized the deployment of mating disruption with the use of unmanned aerial vehicles. We are not continuing this form of mechanization at this time due to challenges with ...
A Comprehensive Study of Aeroelasticity in Flapping-Wing MAVs
2012-08-31
Microrobotics Lab. In previous research we have established the capability to create artificial insect wings with well defined mechanical properties. We have...assumptions on the aerodynamics. 15. SUBJECT TERMS MAV, insect flight, microrobot 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...facilities and expertise of the Harvard Microrobotics Lab. In previous research we have established the capability to create artificial insect wings
1. Overview of EPA Farm Lab Building 1506, Sioux silo ...
1. Overview of EPA Farm Lab Building 15-06, Sioux silo and slaughter addition (featuring poles from hay shed), facing east-northeast. - Nevada Test Site, Environmental Protection Agency Farm, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV
5. View of interior, EPA Farm Lab Building 1506 slaughter ...
5. View of interior, EPA Farm Lab Building 15-06 slaughter addition (featuring cold slaughter area), facing north-northeast - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV
BioLab: Using Yeast Fermentation as a Model for the Scientific Method.
ERIC Educational Resources Information Center
Pigage, Helen K.; Neilson, Milton C.; Greeder, Michele M.
This document presents a science experiment demonstrating the scientific method. The experiment consists of testing the fermentation capabilities of yeasts under different circumstances. The experiment is supported with computer software called BioLab which demonstrates yeast's response to different environments. (YDS)
Some current applications, limitations and future perspectives of lactic acid bacteria as probiotics
Evivie, Smith Etareri; Huo, Gui-Cheng; Igene, John Oamen; Bian, Xin
2017-01-01
ABSTRACT Several mechanism and non-mechanism-based studies supporting the claim that lactic acid bacteria (LAB) strains confer health benefits and play immune-modulatory roles were examined in this review. Probiotic applications of LAB on global burdens such as obesity and type-2 diabetes were discussed as well as the use of yoghurt and ice cream as important vehicles to convey several beneficial LAB strains. Probiotic and symbiotic dairy products may be used in the nearest future to treat a variety of health disorders. Current studies suggest that lactic acid bacteria possess anti-obesity and anti-diabetic propensities on their hosts and thus can play a crucial role in human health care. Research in the rheological and physicochemical properties of ice cream as well as its applications are also on the increase. These applications face certain hurdles including technological (for less developed countries), consumer acceptability of new functional foods may be influenced by culture, ethics or religion. There is need for more studies on the genetic basis for probiotic properties which will give further understanding regarding novel manipulation skills and applicability in nutrition and health sectors. More studies confirming the direct effects of probiotic LABs in lowering the spread of food-borne and other pathogens are also anticipated. PMID:28659729
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab moves overhead toward the open floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab is lowered toward the floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-06-30
KENNEDY SPACE CENTER, FLA. -- The U.S. Lab, a component of the International Space Station, is moved to the vacuum chamber in the Operations and Checkout Building for testing. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber for a leak test. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research.
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab moves overhead toward the open floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-06-30
KENNEDY SPACE CENTER, FLA. -- The U.S. Lab, a component of the International Space Station, is moved to the vacuum chamber in the Operations and Checkout Building for testing. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber for a leak test. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research.
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab is lowered toward the floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab moves overhead after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab moves overhead after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab reaches the open floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab is lowered toward the floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab is lowered toward the floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-07-07
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building, the U.S. Lab reaches the open floor after being lifted out of the vacuum chamber where it was tested for leaks. The test was very successful. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
Revisiting lab-on-a-chip technology for drug discovery.
Neuži, Pavel; Giselbrecht, Stefan; Länge, Kerstin; Huang, Tony Jun; Manz, Andreas
2012-08-01
The field of microfluidics or lab-on-a-chip technology aims to improve and extend the possibilities of bioassays, cell biology and biomedical research based on the idea of miniaturization. Microfluidic systems allow more accurate modelling of physiological situations for both fundamental research and drug development, and enable systematic high-volume testing for various aspects of drug discovery. Microfluidic systems are in development that not only model biological environments but also physically mimic biological tissues and organs; such 'organs on a chip' could have an important role in expediting early stages of drug discovery and help reduce reliance on animal testing. This Review highlights the latest lab-on-a-chip technologies for drug discovery and discusses the potential for future developments in this field.
Mechanics of Granular Materials (MGM0 Flight Hardware in Bench Test
NASA Technical Reports Server (NTRS)
2000-01-01
Engineering bench system hardware for the Mechanics of Granular Materials (MGM) experiment is tested on a lab bench at the University of Colorado in Boulder. This is done in a horizontal arrangement to reduce pressure differences so the tests more closely resemble behavior in the microgravity of space. Sand and soil grains have faces that can cause friction as they roll and slide against each other, or even cause sticking and form small voids between grains. This complex behavior can cause soil to behave like a liquid under certain conditions such as earthquakes or when powders are handled in industrial processes. MGM experiments aboard the Space Shuttle use the microgravity of space to simulate this behavior under conditions that carnot be achieved in laboratory tests on Earth. MGM is shedding light on the behavior of fine-grain materials under low effective stresses. Applications include earthquake engineering, granular flow technologies (such as powder feed systems for pharmaceuticals and fertilizers), and terrestrial and planetary geology. Nine MGM specimens have flown on two Space Shuttle flights. Another three are scheduled to fly on STS-107. The principal investigator is Stein Sture of the University of Colorado at Boulder. (Credit: University of Colorado at Boulder).
Development of a fatigue testing setup for dielectric elastomer membrane actuators
NASA Astrophysics Data System (ADS)
Hill, M.; Rizzello, G.; Seelecke, S.
2017-04-01
Dielectric elastomers (DE's) represent a transduction technology with high potential in many fields, including industries, due to their low weight, flexibility, and small energy consumption. For industrial applications, it is of fundamental importance to quantify the lifetime of DE technology, in terms of electrical and mechanical fatigue, when operating in realistic environmental conditions. This work contributes toward this direction, by presenting the development of an experimental setup which permits systematic fatigue testing of DE membranes. The setup permits to apply both mechanical and electrical stimuli to several membranes simultaneously, while measuring at the same time their mechanical (force, deformation) and electrical response (capacitance, resistance). In its final state, the setup will allow to test up to 15 DE membranes at the same time for several thousands of cycles. Control of the modules, monitoring of the actuators, and data acquisition are realized on a cRio FPGA-system running with LabVIEW. The setup is located in a climate chamber, in order to investigate the fatigue mechanisms at different environmental conditions, i.e., in terms of temperature and humidity. The setup consists of two main parts, namely a fatigue group and a measurement group. The fatigue group stays permanently in the climate chamber, while the measurement group is assembled to the fatigue group and allows to perform measurements at 20°C.
Raga, Roberto; Pivato, Alberto; Lavagnolo, Maria Cristina; Megido, Laura; Cossu, Raffaello
2018-03-01
In this study, a top cover system is investigated as a control for emissions during the aftercare of new landfills and for old landfills where biogas energy production might not be profitable. Different materials were studied as landfill cover system in lab-scale columns: mechanical-biological pretreated municipal solid waste (MBP); mechanical-biological pretreated biowaste (PB); fine (PBS f ) and coarse (PBS c ) mechanical-biological pretreated mixtures of biowaste and sewage sludge, and natural soil (NS). The effectiveness of these materials in removing methane and sulphur compounds from a gas stream was tested, even coupled with activated carbon membranes. Concentrations of CO 2 , CH 4 , O 2 , N 2 , H 2 S and mercaptans were analysed at different depths along the columns. Methane degradation was assessed using mass balance and the results were expressed in terms of methane oxidation rate (MOR). The highest maximum and mean MOR were observed for MBP (17.2gCH 4 /m 2 /hr and 10.3gCH 4 /m 2 /hr, respectively). Similar values were obtained with PB and PBS c . The lowest values of MOR were obtained for NS (6.7gCH 4 /m 2 /hr) and PBS f (3.6gCH 4 /m 2 /hr), which may be due to their low organic content and void index, respectively. Activated membranes with high load capacity did not seem to have an influence on the methane oxidation process: MBP coupled with 220g/m 2 and 360g/m 2 membranes gave maximum MOR of 16.5gCH 4 /m 2 /hr and 17.4gCH 4 /m 2 /hr, respectively. Activated carbon membranes proved to be very effective on H 2 S adsorption. Furthermore, carbonyl sulphide, ethyl mercaptan and isopropyl mercaptan seemed to be easily absorbed by the filling materials. Copyright © 2017. Published by Elsevier B.V.
Lee, Deog Yong; Seo, Yeon-Soo; Rayamajhi, Nabin; Kang, Mi Lan; Lee, Su In; Yoo, Han Sang
2009-12-01
Lactic acid bacteria (LAB) are a well-used probiotics for health improvements in both humans and animals. Despite of several benefits, non-host-specific LAB showed poor probiotics effects due to difficulty in colonization and competition with normal flora. Therefore, the feasibility of porcine LAB isolates was evaluated as a probiotics. Ten of 49 Lactobacillus spp. isolates harbored 2 approximately 10 kb plasmid DNA. Seven strains were selected based on the safety test, such as hemolytic activity, ammonia, indole, and phenylalanine production. After safety test, five strains were selected again by several tests, such as epithelial adherence, antimicrobial activity, tolerance against acid, bile, heat, and cold-drying, and production of acid and hydrogen peroxide. Then, enzyme profiles (ZYM test) and antibiotics resistance were analyzed for further characterization. Five Lactobacillus reuteri isolates from pig feces were selected by safety and functional tests. The plasmid DNA which was able to develop vector system was detected in the isolates. Together with these approaches, pig-specific Lactobacillus spp. originated from pigs were selected. These strains may be useful tools to develop oral delivery system.
Industrial Automation Mechanic Model Curriculum Project. Final Report.
ERIC Educational Resources Information Center
Toledo Public Schools, OH.
This document describes a demonstration program that developed secondary level competency-based instructional materials for industrial automation mechanics. Program activities included task list compilation, instructional materials research, learning activity packet (LAP) development, construction of lab elements, system implementation,…
2013-01-01
Introduction Blood culture (BC) testing before initiation of antimicrobial therapy is recommended as a standard of care in international sepsis guidelines and has been shown to reduce intensive care unit (ICU) stay, antibiotic use, and costs in hospitalized patients. Whereas microbiological laboratory practice has been highly standardized, shortfalls in the preanalytic procedures in the ICU (that is indication, time-to-incubation, blood volume and numbers of BC sets) have a significant effect on the diagnostic yield. The objective of this study was to gain insights into current practices regarding BC testing in intensive care units. Methods Qualitative survey, data collection by 138 semi-structured telephone interviews in four European countries (Italy, UK, France and Germany) between September and November 2009 in 79 clinical microbiology laboratories (LABs) and 59 ICUs. Results Whereas BC testing is expected to remain the gold standard for sepsis diagnostics in all countries, there are substantial differences regarding preanalytic procedures. The decision to launch BC testing is carried out by physicians vs. ICU nurses in the UK in 92 vs. 8%, in France in 75 vs. 25%, in Italy in 88 vs. 12% and in Germany in 92 vs. 8%. Physicians vs. nurses collect BCs in the UK in 77 vs. 23%, in France in 0 vs. 100%, in Italy in 6 vs. 94% and in Germany in 54 vs. 46%. The mean time from blood collection to incubation in the UK is 2 h, in France 3 h, in Italy 4 h, but 20 h in German remote LABs (2 h in in-house LABs), due to the large number of remote nonresident microbiological laboratories in Germany. There were major differences between the perception of the quality of BC testing between ICUs and LABs. Among German ICU respondents, 62% reported that they have no problems with BC testing, 15% reported time constraints, 15% cost pressure, and only 8% too long time to incubation. However, the corresponding LABs of these German ICUs reported too many false positive results due to preanalytical contaminations (49%), insufficient numbers of incoming BC sets (47%), long transportation time (41%) or cost pressure (18%). Conclusions There are considerable differences in the quality of BC testing across European countries. In Germany, time to incubation is a considerable problem due to the increasing number of remote LABs. This is a major issue of concern to physicians aiming to implement sepsis guidelines in the ICUs. PMID:24144084
3. View of EPA Farm Lab Building 1506 (with sliding ...
3. View of EPA Farm Lab Building 15-06 (with sliding doors open to slaughter addition) and Sioux silo, facing north-northwest - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV
2009-07-01
TEAM AMSIO SMT R CRAWFORD W HARRIS 1 ROCK ISLAND ARSENAL ROCK ISLAND IL 61299-6000 7 BENET LABS AMSTA AR CCB M SOJA E KATHE...SPENCER LAB NEWARK DE 19716 1 DEPT OF MECH ENG UNIV OF NEVADA LAS VEGAS M TRABIA 4505 MARYLAND PKWY BOX 454027 LAS VEGAS NV
Mobile e-Learning for Next Generation Communication Environment
ERIC Educational Resources Information Center
Wu, Tin-Yu; Chao, Han-Chieh
2008-01-01
This article develops an environment for mobile e-learning that includes an interactive course, virtual online labs, an interactive online test, and lab-exercise training platform on the fourth generation mobile communication system. The Next Generation Learning Environment (NeGL) promotes the term "knowledge economy." Inter-networking…
76 FR 159 - Discretionary Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-03
... detection of iron deficiency, another pediatric health issue. Proficiency testing (PT) is a proven method... monthly PT and other lab quality improvement tools to nearly 600 laboratories across the U.S. and beyond... Competition: The participation of large numbers of these labs in voluntary proficiency was by design, and...
Tang, Y; Saris, P E J
2013-10-01
Lactobacillus acidophilus LAB20 has potential to be a probiotic strain because it can be present at high numbers in the jejunum of dog. To specifically detect LAB20 from dog faecal samples, a real-time PCR protocol was developed targeting the novel surface (S) layer protein gene of LAB20. The presence of S-layer protein was verified by N-terminal sequencing of the approximately 50-kDa major band from SDS-PAGE gel. The corresponding S-layer gene was amplified by inverse PCR using homology to known S-layers and sequenced. This novel S-layer protein has low sequence similarity to other S-layer proteins in the N-terminal region (32-211 aa, 7-39%). This enabled designing strain-specific PCR primers. The primer set was utilized to study intestinal persistence of LAB20 in dog that was fed with LAB20 fermented milk for 5 days. The results showed that LAB20 can be detected from dog faecal sample after 6 weeks with 10(4·53) DNA copies g(-1) postadministration. It suggested that LAB20 could be a good candidate to study the mechanism behind its persistence and dominance in dog intestine and maybe utilize it as a probiotic for canine. A real-time PCR method was developed to detect Lactobacillus acidophilus LAB20, a strain that was previously found dominant in canine gastrointestinal (GI) tract. The quantitative detection was based on targeting to variation region of a novel S-layer protein found in LAB20, allowing to specifically enumerate LAB20 from dog faeces. The results showed that the real-time PCR method was sensitive enough to be used in later intervention studies. Interestingly, LAB20 was found to persist in dog GI tract for 6 weeks. Therefore, LAB20 could be a good candidate to study its colonization and potentially utilize as a canine probiotic. © 2013 The Society for Applied Microbiology.
2000-06-28
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building (O&C), an overhead crane hovers over the U.S. Lab, named Destiny, while workers attach cables for lifting the Lab. The Lab will undergo testing in the altitude chamber in the O&C. Destiny is scheduled to fly on mission STS-98 in early 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
2000-06-28
KENNEDY SPACE CENTER, FLA. -- In the Operations and Checkout Building (O&C), an overhead crane hovers over the U.S. Lab, named Destiny, while workers attach cables for lifting the Lab. The Lab will undergo testing in the altitude chamber in the O&C. Destiny is scheduled to fly on mission STS-98 in early 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research
Carrying BioMath education in a Leaky Bucket.
Powell, James A; Kohler, Brynja R; Haefner, James W; Bodily, Janice
2012-09-01
In this paper, we describe a project-based mathematical lab implemented in our Applied Mathematics in Biology course. The Leaky Bucket Lab allows students to parameterize and test Torricelli's law and develop and compare their own alternative models to describe the dynamics of water draining from perforated containers. In the context of this lab students build facility in a variety of applied biomathematical tools and gain confidence in applying these tools in data-driven environments. We survey analytic approaches developed by students to illustrate the creativity this encourages as well as prepare other instructors to scaffold the student learning experience. Pedagogical results based on classroom videography support the notion that the Biology-Applied Math Instructional Model, the teaching framework encompassing the lab, is effective in encouraging and maintaining high-level cognition among students. Research-based pedagogical approaches that support the lab are discussed.
Barbieri, Andrea; Mantovani, Francesca; Bursi, Francesca; Bartolacelli, Ylenia; Manicardi, Marcella; Lauria, Maria Giulia; Boriani, Giuseppe
2018-01-01
Data on stress echocardiography (SE) time-related changes in referral patterns and diagnostic yield for detection of inducible ischemia could enhance Echo Lab quality benchmarks and performance measures. This study aims to evaluate temporal trends in SE test results among ambulatory patients with suspected or known coronary artery disease (CAD) in a tertiary care referral center with moderate (>100/year) volume SE activities and Cath-Lab facility. From January 2004 to December 2015, 1954 patients (mean age 62 ± 12 years, 42% women, 27% with known CAD) underwent SE (1673 exercise SE, 86%, 246 pharmacological SE, 12%, 35 pacing SE, 2%). Time was grouped into three 4 year periods, where clinical data and test results were evaluated. Our series comprised low-to-intermediate pretest probability of CAD throughout the observation period (overall pretest probability of CAD 19% ± 15%). A progressive decline over time in the rate of pharmacological SE instead of a dramatic increment of exercise SE (79%-96%, P < 0.0001) was noted. The use of beta-blockers increased (from 43% to 66%, P < 0.0001), while the use of nitrates decreased (from 11% to 4%, P < 0.0001) over time. We noted a very uncommon occurrence of abnormal test results with a further decrease in the last period (from 11% to 3%, P < 0.0001). We observed, over a 12-year period, a progressive decrease in the frequency of inducible myocardial ischemia among patients with known or suspected CADe referred to our Echo Lab for SE with Cath-Lab facility, and this trend was parallel to changes in SE referral practice. These findings are particularly relevant if we consider the practical implications on diagnostic SE accuracy and risk assessment.
Kopiske, Karl K; Bruno, Nicola; Hesse, Constanze; Schenk, Thomas; Franz, Volker H
2016-06-01
It has often been suggested that visual illusions affect perception but not actions such as grasping, as predicted by the "two-visual-systems" hypothesis of Milner and Goodale (1995, The Visual Brain in Action, Oxford University press). However, at least for the Ebbinghaus illusion, relevant studies seem to reveal a consistent illusion effect on grasping (Franz & Gegenfurtner, 2008. Grasping visual illusions: consistent data and no dissociation. Cognitive Neuropsychology). Two interpretations are possible: either grasping is not immune to illusions (arguing against dissociable processing mechanisms for vision-for-perception and vision-for-action), or some other factors modulate grasping in ways that mimic a vision-for perception effect in actions. It has been suggested that one such factor may be obstacle avoidance (Haffenden Schiff & Goodale, 2001. The dissociation between perception and action in the Ebbinghaus illusion: nonillusory effects of pictorial cues on grasp. Current Biology, 11, 177-181). In four different labs (total N = 144), we conducted an exact replication of previous studies suggesting obstacle avoidance mechanisms, implementing conditions that tested grasping as well as multiple perceptual tasks. This replication was supplemented by additional conditions to obtain more conclusive results. Our results confirm that grasping is affected by the Ebbinghaus illusion and demonstrate that this effect cannot be explained by obstacle avoidance. Copyright © 2016 Elsevier Ltd. All rights reserved.
Engineering lactic acid bacteria for increased industrial functionality.
Bron, Peter A; Kleerebezem, Michiel
2011-01-01
Based on their spoilage-preventing and flavor-contributing characteristics, lactic acid bacteria (LAB) are employed as starter cultures for the fermentation of foods and feeds. In addition, several specific LAB strains are marketed on basis of their beneficial effects on the consumer's health, representing an explosively growing market for the products containing these so-called probiotics. Due to this extensive industrial use there is a strong interest in unraveling the molecular mechanisms involved in industrial robustness, cognate stress resistance, and health-promoting phenotypes of these LAB that may vary drastically between different starter and probiotic strains currently marketed. This review describes some of the post-genomic tools developed, as well as their employment for the identification of bacterial effector molecules involved in the aforementioned industrially relevant phenotypes. Furthermore, it addresses possible strategies to exploit such knowledge into the rational design of LAB strains with increased industrial functionality.
Attack of the Killer Fungus: A Hypothesis-Driven Lab Module †
Sato, Brian K.
2013-01-01
Discovery-driven experiments in undergraduate laboratory courses have been shown to increase student learning and critical thinking abilities. To this end, a lab module involving worm capture by a nematophagous fungus was developed. The goals of this module are to enhance scientific understanding of the regulation of worm capture by soil-dwelling fungi and for students to attain a set of established learning goals, including the ability to develop a testable hypothesis and search for primary literature for data analysis, among others. Students in a ten-week majors lab course completed the lab module and generated novel data as well as data that agrees with the published literature. In addition, learning gains were achieved as seen through a pre-module and post-module test, student self-assessment, class exam, and lab report. Overall, this lab module enables students to become active participants in the scientific method while contributing to the understanding of an ecologically relevant model organism. PMID:24358387
Optical development system lab alignment solutions for the ICESat-2 ATLAS instrument
NASA Astrophysics Data System (ADS)
Evans, T.
The ATLAS Instrument for the ICESat-2 mission at NASA's Goddard Space Flight Center requires an alignment test-bed to prove out new concepts. The Optical Development System (ODS) lab was created to test prototype models of individual instrument components to simulate how they will act as a system. The main ICESat-2 instrument is the Advanced Topographic Laser Altimeter System (ATLAS). It measures ice elevation by transmitting laser pulses, and collecting the reflection in a telescope. Because the round trip time is used to calculate distance, alignment between the outgoing transmitter beam and the incoming receiver beams are critical. An automated closed loop monitoring control system is currently being tested at the prototype level to prove out implementation for the final spacecraft. To achieve an error of less than 2 micro-radians, an active deformable mirror was used to correct the lab wave front from the collimated “ ground reflection” beam. The lab includes a focal plane assembly set up, a one meter diameter collimator optic, and a 0.8 meter flight spare telescope for alignment. ATLAS prototypes and engineering models of transmitter and receiver optics and sub-systems are brought in to develop and integrate systems as well as write procedures to be used in integration and testing. By having a fully integrated system with prototypes and engineering units, lessons can be learned before flight designs are finalized.
Human perception testing methodology for evaluating EO/IR imaging systems
NASA Astrophysics Data System (ADS)
Graybeal, John J.; Monfort, Samuel S.; Du Bosq, Todd W.; Familoni, Babajide O.
2018-04-01
The U.S. Army's RDECOM CERDEC Night Vision and Electronic Sensors Directorate (NVESD) Perception Lab is tasked with supporting the development of sensor systems for the U.S. Army by evaluating human performance of emerging technologies. Typical research questions involve detection, recognition and identification as a function of range, blur, noise, spectral band, image processing techniques, image characteristics, and human factors. NVESD's Perception Lab provides an essential bridge between the physics of the imaging systems and the performance of the human operator. In addition to quantifying sensor performance, perception test results can also be used to generate models of human performance and to drive future sensor requirements. The Perception Lab seeks to develop and employ scientifically valid and efficient perception testing procedures within the practical constraints of Army research, including rapid development timelines for critical technologies, unique guidelines for ethical testing of Army personnel, and limited resources. The purpose of this paper is to describe NVESD Perception Lab capabilities, recent methodological improvements designed to align our methodology more closely with scientific best practice, and to discuss goals for future improvements and expanded capabilities. Specifically, we discuss modifying our methodology to improve training, to account for human fatigue, to improve assessments of human performance, and to increase experimental design consultation provided by research psychologists. Ultimately, this paper outlines a template for assessing human perception and overall system performance related to EO/IR imaging systems.
2000-10-23
In the Space Station Processing Facility, a worker is surprised by the camera as she exits the U.S. Lab, Destiny. Inside the lab is the STS-98 crew, which is taking part in Crew Equipment Interface Test activities, becoming familiar with equipment it will be handling during the mission. The crew comprises Commander Ken Cockrell, Pilot Mark Polansky and Mission Specialists Robert Curbeam, Thomas Jones and Marsha Ivins. The mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. With delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated. The STS-98 launch is scheduled for Jan. 18, 2001
2000-10-23
In the Space Station Processing Facility, STS-98 Mission Specialist Marsha Ivins wields a tool on part of the U.S. Lab, Destiny. The crew is checking out equipment inside the lab as part of Crew Equipment Interface Test activities, becoming familiar with equipment it will be handling during the mission. Others in the crew are Commander Ken Cockrell, Pilot Mark Polansky and Mission Specialists Robert Curbeam and Thomas Jones. The mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. With delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated. The STS-98 launch is scheduled for Jan. 18, 2001
2000-10-23
In the Space Station Processing Facility, STS-98 Mission Specialist Marsha Ivins maneuvers a part of the U.S. Lab, Destiny. The crew is checking out equipment inside the lab as part of Crew Equipment Interface Test activities, becoming familiar with equipment it will be handling during the mission. Others in the crew are Commander Ken Cockrell, Pilot Mark Polansky and Mission Specialists Robert Curbeam and Thomas Jones. The mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. With delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated. The STS-98 launch is scheduled for Jan. 18, 2001
Trading Carbon: Can Cookstoves Light the Way (LBNL Science at the Theater)
Gadgil, Ashok; Booker, Kayje; Rausch, Adam
2018-06-08
Science at the Theater: Get smart about carbon! Learn how families in Africa, using stoves designed by Berkeley Lab, are at the forefront of global carbon reduction. Ashok Gadgil is the driving force behind the Berkeley-Darfur Cookstove. He is a researcher, inventor, renowned humanitarian, and director of Berkeley Lab's Environmental Energy Technologies Division. Kayje Booker is a Berkeley Lab researcher and UC Berkeley graduate student in ecosystem sciences. She is exploring how carbon markets can serve as catalysts for innovation in technologies for the poor. Adam Rausch is a Berkeley Lab researcher and UC Berkeley graduate student in civil environmental engineering. He helps to design and test stove designs in Ethiopia and elsewhere.
STS-98 crew members take part in CEIT
NASA Technical Reports Server (NTRS)
2000-01-01
In the Space Station Processing Facility, a worker is surprised by the camera as she exits the U.S. Lab, Destiny. Inside the lab is the STS-98 crew, which is taking part in Crew Equipment Interface Test activities, becoming familiar with equipment it will be handling during the mission. The crew comprises Commander Ken Cockrell, Pilot Mark Polansky and Mission Specialists Robert Curbeam, Thomas Jones and Marsha Ivins. The mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. With delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated. The STS-98 launch is scheduled for Jan. 18, 2001.
STS-98 crew members take part in CEIT
NASA Technical Reports Server (NTRS)
2000-01-01
In the Space Station Processing Facility, STS-98 Mission Specialist Marsha Ivins maneuvers a part of the U.S. Lab, Destiny. The crew is checking out equipment inside the lab as part of Crew Equipment Interface Test activities, becoming familiar with equipment it will be handling during the mission. Others in the crew are Commander Ken Cockrell, Pilot Mark Polansky and Mission Specialists Robert Curbeam and Thomas Jones. The mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. With delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated. The STS-98 launch is scheduled for Jan. 18, 2001.
High-gradient SRF R&D for ILC at Jefferson Lab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geng, Rongli; Crawford, Anthony; Ciovati, Gianluigi
2008-10-01
Jefferson Lab plays an active role in high-gradient SRF R&D in the frame work of the internationally coordinated ILC S0 program. The S0 aim is to push the yield at 35 MV/m in 9-cell cavities. So far, twelve cavities have been electropolishing (EP) processed and RF tested by using the state-of-the-art recipes at JLab, in close collaboration with FNAL and KEK. Seven of them reached a best gradient of over 31.5 MV/m. Understanding gradient limiting mechanisms in real 9-cell cavities is an important component of our studies. Thermometry and high-resolution optical inspection are used to locate and understand the sourcemore » of gradient limits. Experimenting with selective cavities is still a necessary method for process optimization. One example is the first demonstration of 35 MV/m without detectable Bremsstrahlung X-ray after a light EP is applied to a previously heavy BCP etched 7-cell cavity. Some new understanding has been gained with regard to quench behaviors, field emission behaviors as« less
Why do lab-scale experiments ever resemble geological scale patterning?
NASA Astrophysics Data System (ADS)
Ferdowsi, Behrooz; Jones, Brandon C.; Stein, Jeremy L.; Shinbrot, Troy
2017-11-01
The Earth and other planets are abundant with curious and poorly understood surface patterns. Examples include sand dunes, periodic and aperiodic ridges and valleys, and networks of river and submarine channels. We make the minimalist proposition that the dominant mechanism governing these varied patterns is mass conservation: notwithstanding detailed particulars, the universal rule is mass conservation and there are only a finite number of surface patterns that can result from this process. To test this minimalist proposition, we perform experiments in a vertically vibrated bed of fine grains, and we show that every one of a wide variety of patterns seen in the laboratory is also seen in recorded geomorphologies. We explore a range of experimental driving frequencies and amplitudes, and we complement these experimental results with a non-local cellular automata model that reproduces the surface patterns seen using a minimalist approach that allows a free surface to deform subject to mass conservation and simple known forces such as gravity. These results suggest a common cause for the effectiveness of lab-scale models for geological scale patterning that otherwise ought to have no reasonable correspondence.
Metabolic strategies of beer spoilage lactic acid bacteria in beer.
Geissler, Andreas J; Behr, Jürgen; von Kamp, Kristina; Vogel, Rudi F
2016-01-04
Beer contains only limited amounts of readily fermentable carbohydrates and amino acids. Beer spoilage lactic acid bacteria (LAB) have to come up with metabolic strategies in order to deal with selective nutrient content, high energy demand of hop tolerance mechanisms and a low pH. The metabolism of 26 LAB strains of 6 species and varying spoilage potentialwas investigated in order to define and compare their metabolic capabilities using multivariate statistics and outline possible metabolic strategies. Metabolic capabilities of beer spoilage LAB regarding carbohydrate and amino acids did not correlate with spoilage potential, but with fermentation type (heterofermentative/homofermentative) and species. A shift to mixed acid fermentation by homofermentative (hof) Pediococcus claussenii and Lactobacillus backii was observed as a specific feature of their growth in beer. For heterofermentative (hef) LAB a mostly versatile carbohydrate metabolism could be demonstrated, supplementing the known relevance of organic acids for their growth in beer. For hef LAB a distinct amino acid metabolism, resulting in biogenic amine production, was observed, presumably contributing to energy supply and pH homeostasis.
4. Oblique view of EPA Farm Lab Building 1506 (with ...
4. Oblique view of EPA Farm Lab Building 15-06 (with sliding door open to milking area), Sioux silo and slaughter addition, facing northeast - Nevada Test Site, Environmental Protection Agency Farm, Laboratory Building, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV
77 FR 12867 - Accreditation of ALTOL Chemical and Environmental Lab Inc., as a Commercial Laboratory
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-02
... accredited to test petroleum, petroleum products, organic chemicals and vegetable oils for customs purposes... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Accreditation of ALTOL Chemical..., Department of Homeland Security. ACTION: Notice of accreditation of Altol Chemical and Environmental Lab Inc...
Science Labs: Beyond Isolationism
ERIC Educational Resources Information Center
Cavanagh, Sean
2007-01-01
A national study released in 2005 concluded that most high school students are not exposed to high quality science labs because of these reasons: (a) poor school facilities and organizations; (b) weak teacher preparation; (c) poor design; (d) cluttered state standards; (e) little representation on state tests; and (f) scarce evidence of what…
Virtual Labs vs. Remote Labs: Between Myth & Reality.
ERIC Educational Resources Information Center
Alhalabi, Bassem; Hamza, M. Khalid; Hsu, Sam; Romance, Nancy
Many United States institutions of higher education have established Web-based educational environments that provide higher education curricula via the Internet and diverse modalities. Success has been limited primarily to virtual classrooms (real audio/video transmission) and/or test taking (online form filing). An extensive survey was carried…
Aerobic fitness and performance in elite female futsal players
Subiela, JV; Granda-Vera, J; Castagna, C; Gómez, M; Del Coso, J
2015-01-01
Despite its growing popularity, few studies have investigated specific physiological demands for elite female futsal. The aim of this study was to determine aerobic fitness in elite female futsal players using laboratory and field testing. Fourteen female futsal players from the Venezuelan National team (age =21.2±4.0 years; body mass =58.6±5.6 kg; height =161±5.0 cm) performed a progressive maximal treadmill test under laboratory conditions. Players also performed a progressive intermittent futsal-specific field test for endurance, the Futsal Intermittent Endurance Test (FIET), until volitional fatigue. Outcome variables were exercise heart rate (HR), VO2, post-exercise blood lactate concentrations ([La]b) and running speeds (km · h-1). During the treadmill test, VO2max, maximal aerobic speed (MAS), HR and peak [La]b were 45.3±5.6 ml · kg-1 · min-1, 12.5±1.77 km · h-1, 197±8 beats · min-1 and 11.3±1.4 mmol · l-1, respectively. The FIET total distance, peak running velocity, peak HR and [La]b were 1125.0±121.0 m, 15.2±0.5 km · h-1, 199±8 beats · min-1 and 12.5±2.2 mmol · l-1, respectively. The FIET distance and peak speed were strongly associated (r= 0.85-87, p < 0.0001) with VO2max and MAS, respectively. Peak HR and [La]b were not significantly different between tests. Elite female futsal players possess moderate aerobic fitness. Furthermore, the FIET can be considered as a valid field test to determine aerobic fitness in elite level female futsal players. PMID:28479664
Aerobic fitness and performance in elite female futsal players.
Barbero-Alvarez, J C; Subiela, J V; Granda-Vera, J; Castagna, C; Gómez, M; Del Coso, J
2015-12-01
Despite its growing popularity, few studies have investigated specific physiological demands for elite female futsal. The aim of this study was to determine aerobic fitness in elite female futsal players using laboratory and field testing. Fourteen female futsal players from the Venezuelan National team (age =21.2±4.0 years; body mass =58.6±5.6 kg; height =161±5.0 cm) performed a progressive maximal treadmill test under laboratory conditions. Players also performed a progressive intermittent futsal-specific field test for endurance, the Futsal Intermittent Endurance Test (FIET), until volitional fatigue. Outcome variables were exercise heart rate (HR), VO 2 , post-exercise blood lactate concentrations ([La]b) and running speeds (km · h -1 ). During the treadmill test, VO 2 max, maximal aerobic speed (MAS), HR and peak [La]b were 45.3±5.6 ml · kg -1 · min -1 , 12.5±1.77 km · h -1 , 197±8 beats · min -1 and 11.3±1.4 mmol · l -1 , respectively. The FIET total distance, peak running velocity, peak HR and [La]b were 1125.0±121.0 m, 15.2±0.5 km · h -1 , 199±8 beats · min -1 and 12.5±2.2 mmol · l -1 , respectively. The FIET distance and peak speed were strongly associated (r= 0.85-87, p < 0.0001) with VO 2 max and MAS, respectively. Peak HR and [La]b were not significantly different between tests. Elite female futsal players possess moderate aerobic fitness. Furthermore, the FIET can be considered as a valid field test to determine aerobic fitness in elite level female futsal players.
2017-01-01
Background Laboratory testing is roughly divided into three phases: a pre-analytical phase, an analytical phase and a post-analytical phase. Most analytical errors have been attributed to the analytical phase. However, recent studies have shown that up to 70% of analytical errors reflect the pre-analytical phase. The pre-analytical phase comprises all processes from the time a laboratory request is made by a physician until the specimen is analyzed at the lab. Generally, the pre-analytical phase includes patient preparation, specimen transportation, specimen collection and storage. In the present study, we report the first comprehensive assessment of the frequency and types of pre-analytical errors at the Sulaimani diagnostic labs in Iraqi Kurdistan. Materials and Methods Over 2 months, 5500 venous blood samples were observed in 10 public diagnostic labs of Sulaimani City. The percentages of rejected samples and types of sample inappropriateness were evaluated. The percentage of each of the following pre-analytical errors were recorded: delay in sample transportation, clotted samples, expired reagents, hemolyzed samples, samples not on ice, incorrect sample identification, insufficient sample, tube broken in centrifuge, request procedure errors, sample mix-ups, communication conflicts, misinterpreted orders, lipemic samples, contaminated samples and missed physician’s request orders. The difference between the relative frequencies of errors observed in the hospitals considered was tested using a proportional Z test. In particular, the survey aimed to discover whether analytical errors were recorded and examine the types of platforms used in the selected diagnostic labs. Results The analysis showed a high prevalence of improper sample handling during the pre-analytical phase. In appropriate samples, the percentage error was as high as 39%. The major reasons for rejection were hemolyzed samples (9%), incorrect sample identification (8%) and clotted samples (6%). Most quality control schemes at Sulaimani hospitals focus only on the analytical phase, and none of the pre-analytical errors were recorded. Interestingly, none of the labs were internationally accredited; therefore, corrective actions are needed at these hospitals to ensure better health outcomes. Internal and External Quality Assessment Schemes (EQAS) for the pre-analytical phase at Sulaimani clinical laboratories should be implemented at public hospitals. Furthermore, lab personnel, particularly phlebotomists, need continuous training on the importance of sample quality to obtain accurate test results. PMID:28107395
Najat, Dereen
2017-01-01
Laboratory testing is roughly divided into three phases: a pre-analytical phase, an analytical phase and a post-analytical phase. Most analytical errors have been attributed to the analytical phase. However, recent studies have shown that up to 70% of analytical errors reflect the pre-analytical phase. The pre-analytical phase comprises all processes from the time a laboratory request is made by a physician until the specimen is analyzed at the lab. Generally, the pre-analytical phase includes patient preparation, specimen transportation, specimen collection and storage. In the present study, we report the first comprehensive assessment of the frequency and types of pre-analytical errors at the Sulaimani diagnostic labs in Iraqi Kurdistan. Over 2 months, 5500 venous blood samples were observed in 10 public diagnostic labs of Sulaimani City. The percentages of rejected samples and types of sample inappropriateness were evaluated. The percentage of each of the following pre-analytical errors were recorded: delay in sample transportation, clotted samples, expired reagents, hemolyzed samples, samples not on ice, incorrect sample identification, insufficient sample, tube broken in centrifuge, request procedure errors, sample mix-ups, communication conflicts, misinterpreted orders, lipemic samples, contaminated samples and missed physician's request orders. The difference between the relative frequencies of errors observed in the hospitals considered was tested using a proportional Z test. In particular, the survey aimed to discover whether analytical errors were recorded and examine the types of platforms used in the selected diagnostic labs. The analysis showed a high prevalence of improper sample handling during the pre-analytical phase. In appropriate samples, the percentage error was as high as 39%. The major reasons for rejection were hemolyzed samples (9%), incorrect sample identification (8%) and clotted samples (6%). Most quality control schemes at Sulaimani hospitals focus only on the analytical phase, and none of the pre-analytical errors were recorded. Interestingly, none of the labs were internationally accredited; therefore, corrective actions are needed at these hospitals to ensure better health outcomes. Internal and External Quality Assessment Schemes (EQAS) for the pre-analytical phase at Sulaimani clinical laboratories should be implemented at public hospitals. Furthermore, lab personnel, particularly phlebotomists, need continuous training on the importance of sample quality to obtain accurate test results.
Zheng, Yu; Mou, Jun; Niu, Jiwei; Yang, Shuai; Chen, Lin; Xia, Menglei; Wang, Min
2018-03-01
Lactic acid bacteria (LAB) are essential microbiota for the fermentation and flavor formation of Shanxi aged vinegar, a famous Chinese traditional cereal vinegar that is manufactured using open solid-state fermentation (SSF) technology. However, the dynamics of LAB in this SSF process and the underlying mechanism remain poorly understood. Here, the diversity of LAB and the potential driving factors of the entire process were analyzed by combining culture-independent and culture-dependent methods. Canonical correlation analysis indicated that ethanol, acetic acid, and temperature that result from the metabolism of microorganisms serve as potential driving factors for LAB succession. LAB strains were periodically isolated, and the characteristics of 57 isolates on environmental factor tolerance and substrate utilization were analyzed to understand the succession sequence. The environmental tolerance of LAB from different stages was in accordance with their fermentation conditions. Remarkable correlations were identified between LAB growth and environmental factors with 0.866 of ethanol (70 g/L), 0.756 of acetic acid (10 g/L), and 0.803 of temperature (47 °C). More gentle or harsh environments (less or more than 60 or 80 g/L of ethanol, 5 or 20 g/L of acetic acid, and 30 or 55 °C temperature) did not affect the LAB succession. The utilization capability evaluation of the 57 isolates for 95 compounds proved that strains from different fermentation stages exhibited different predilections on substrates to contribute to the fermentation at different stages. Results demonstrated that LAB succession in the SSF process was driven by the capabilities of environmental tolerance and substrate utilization.
Polarimetry of the polarized hydrogen deuteride HDice target under an electron beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laine, Vivien E.
2013-10-01
The study of the nucleon structure has been a major research focus in fundamental physics in the past decades and still is the main research line of the Thomas Jefferson National Accelerator Facility (Jefferson Lab). For this purpose and to obtain statistically meaningful results, having both a polarized beam and a highly efficient polarized target is essential. For the target, this means high polarization and high relative density of polarized material. A Hydrogen Deuteride (HD) target that presents both such characteristics has been developed first at Brookhaven National Lab (BNL) and brought to the Hall B of Jefferson Lab inmore » 2008. The HD target has been shown to work successfully under a high intensity photon beam (BNL and Jefferson Lab). However, it remained to be seen if the target could stand an electron beam of reasonably high current (nA). In this perspective, the target was tested for the first time in its frozen spin mode under an electron beam at Jefferson Lab in 2012 during the g14 experiment. This dissertation presents the principles and usage procedures of this HD target. The polarimetry of this target with Nuclear Magnetic Resonance (NMR) during the electron beam tests is also discussed. In addition, this dissertation also describes another way to perform target polarimetry with the elastic scattering of electrons off a polarized target by using data taken on helium-3 during the E97-110 experiment that occurred in Jefferson Lab's Hall A in 2003.« less
... measurement for a result of this test. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...
De Vuyst, Luc; Schrijvers, Vincent; Paramithiotis, Spiros; Hoste, Bart; Vancanneyt, Marc; Swings, Jean; Kalantzopoulos, George; Tsakalidou, Effie; Messens, Winy
2002-01-01
Lactic acid bacteria (LAB) were isolated from Greek traditional wheat sourdoughs manufactured without the addition of baker's yeast. Application of sodium dodecyl sulfate-polyacrylamide gel electrophoresis of total cell protein, randomly amplified polymorphic DNA-PCR, DNA-DNA hybridization, and 16S ribosomal DNA sequence analysis, in combination with physiological traits such as fructose fermentation and mannitol production, allowed us to classify the isolated bacteria into the species Lactobacillus sanfranciscensis, Lactobacillus brevis, Lactobacillus paralimentarius, and Weissella cibaria. This consortium seems to be unique for the Greek traditional wheat sourdoughs studied. Strains of the species W. cibaria have not been isolated from sourdoughs previously. No Lactobacillus pontis or Lactobacillus panis strains were found. An L. brevis-like isolate (ACA-DC 3411 t1) could not be identified properly and might be a new sourdough LAB species. In addition, fermentation capabilities associated with the LAB detected have been studied. During laboratory fermentations, all heterofermentative sourdough LAB strains produced lactic acid, acetic acid, and ethanol. Mannitol was produced from fructose that served as an additional electron acceptor. In addition to glucose, almost all of the LAB isolates fermented maltose, while fructose as the sole carbohydrate source was fermented by all sourdough LAB tested except L. sanfranciscensis. Two of the L. paralimentarius isolates tested did not ferment maltose; all strains were homofermentative. In the presence of both maltose and fructose in the medium, induction of hexokinase activity occurred in all sourdough LAB species mentioned above, explaining why no glucose accumulation was found extracellularly. No maltose phosphorylase activity was found either. These data produced a variable fermentation coefficient and a unique sourdough metabolite composition. PMID:12450829
MethLAB: a graphical user interface package for the analysis of array-based DNA methylation data.
Kilaru, Varun; Barfield, Richard T; Schroeder, James W; Smith, Alicia K; Conneely, Karen N
2012-03-01
Recent evidence suggests that DNA methylation changes may underlie numerous complex traits and diseases. The advent of commercial, array-based methods to interrogate DNA methylation has led to a profusion of epigenetic studies in the literature. Array-based methods, such as the popular Illumina GoldenGate and Infinium platforms, estimate the proportion of DNA methylated at single-base resolution for thousands of CpG sites across the genome. These arrays generate enormous amounts of data, but few software resources exist for efficient and flexible analysis of these data. We developed a software package called MethLAB (http://genetics.emory.edu/conneely/MethLAB) using R, an open source statistical language that can be edited to suit the needs of the user. MethLAB features a graphical user interface (GUI) with a menu-driven format designed to efficiently read in and manipulate array-based methylation data in a user-friendly manner. MethLAB tests for association between methylation and relevant phenotypes by fitting a separate linear model for each CpG site. These models can incorporate both continuous and categorical phenotypes and covariates, as well as fixed or random batch or chip effects. MethLAB accounts for multiple testing by controlling the false discovery rate (FDR) at a user-specified level. Standard output includes a spreadsheet-ready text file and an array of publication-quality figures. Considering the growing interest in and availability of DNA methylation data, there is a great need for user-friendly open source analytical tools. With MethLAB, we present a timely resource that will allow users with no programming experience to implement flexible and powerful analyses of DNA methylation data.
De Vuyst, Luc; Schrijvers, Vincent; Paramithiotis, Spiros; Hoste, Bart; Vancanneyt, Marc; Swings, Jean; Kalantzopoulos, George; Tsakalidou, Effie; Messens, Winy
2002-12-01
Lactic acid bacteria (LAB) were isolated from Greek traditional wheat sourdoughs manufactured without the addition of baker's yeast. Application of sodium dodecyl sulfate-polyacrylamide gel electrophoresis of total cell protein, randomly amplified polymorphic DNA-PCR, DNA-DNA hybridization, and 16S ribosomal DNA sequence analysis, in combination with physiological traits such as fructose fermentation and mannitol production, allowed us to classify the isolated bacteria into the species Lactobacillus sanfranciscensis, Lactobacillus brevis, Lactobacillus paralimentarius, and Weissella cibaria. This consortium seems to be unique for the Greek traditional wheat sourdoughs studied. Strains of the species W. cibaria have not been isolated from sourdoughs previously. No Lactobacillus pontis or Lactobacillus panis strains were found. An L. brevis-like isolate (ACA-DC 3411 t1) could not be identified properly and might be a new sourdough LAB species. In addition, fermentation capabilities associated with the LAB detected have been studied. During laboratory fermentations, all heterofermentative sourdough LAB strains produced lactic acid, acetic acid, and ethanol. Mannitol was produced from fructose that served as an additional electron acceptor. In addition to glucose, almost all of the LAB isolates fermented maltose, while fructose as the sole carbohydrate source was fermented by all sourdough LAB tested except L. sanfranciscensis. Two of the L. paralimentarius isolates tested did not ferment maltose; all strains were homofermentative. In the presence of both maltose and fructose in the medium, induction of hexokinase activity occurred in all sourdough LAB species mentioned above, explaining why no glucose accumulation was found extracellularly. No maltose phosphorylase activity was found either. These data produced a variable fermentation coefficient and a unique sourdough metabolite composition.
Hemoglobin Test: MedlinePlus Lab Test Information
... page: https://medlineplus.gov/labtests/hemoglobintest.html Hemoglobin Test To use the sharing features on this page, please enable JavaScript. What is a Hemoglobin Test? A hemoglobin test measures the levels of hemoglobin ...
Procalcitonin Test: MedlinePlus Lab Test Information
... page: https://medlineplus.gov/labtests/procalcitonintest.html Procalcitonin Test To use the sharing features on this page, please enable JavaScript. What is a Procalcitonin Test? A procalcitonin test measures the level of procalcitonin ...
Amylase Test: MedlinePlus Lab Test Information
... page: https://medlineplus.gov/labtests/amylasetest.html Amylase Test To use the sharing features on this page, please enable JavaScript. What is an Amylase Test? An amylase test measures the amount of amylase ...
Hematocrit Test: MedlinePlus Lab Test Information
... page: https://medlineplus.gov/labtests/hematocrittest.html Hematocrit Test To use the sharing features on this page, please enable JavaScript. What is a Hematocrit Test? A hematocrit test is a type of blood ...
F/A-18 forebody vortex control. Volume 2: Rotary-balance tests
NASA Technical Reports Server (NTRS)
Kramer, Brian R.; Suarez, Carlos J.; Malcolm, Gerald N.; Ayers, Bert F.
1994-01-01
A rotary-balance wind tunnel test was conducted on a six percent model of the F/A-18 at the NASA Ames 7 X 10-Foot Low Speed Wind Tunnel. The data reduction was specially written for the test in National Instruments' LabVIEW. The data acquisition, reduction and analysis was performed with a Macintosh computer. The primary objective of the test was to evaluate the effectiveness of several forebody vortex control configurations in a rotary flow field. The devices that were found to be the most effective during the static tests (Volume 1) were investigated and included both mechanical and pneumatic configurations. The mechanical systems evaluated were small, single and dual, rotating nose tip strakes and a vertical nose strake. The jet blowing configuration used nozzles canted inboard 60 degrees. A two segment tangential slot was also evaluated. The different techniques were evaluated at angles of attack of 30 degrees, 45 degrees, 51 degrees, and 60 degrees. Sideslip and Reynolds number were varied for some of the configurations. All of the techniques proved to be effective in the rotating flow field. The vertical nose strake had the largest 'envelope' of effectiveness. Forebody vortex control provides large, robust yawing moments at medium to high angles of attack, even during combat maneuvers such as loaded roll.
NASA Technical Reports Server (NTRS)
1995-01-01
The motor/encoder (henceforth referred to as the UUT) test sequence began with a baseline functional evaluation, which demonstrated that the motor satisfied the operating torque, cogging torque, winding resistance, and mechanical requirements of SOW. In addition, the encoder electrical requirements were verified, as well as the alignment of the encoder outputs relative to the motor shaft position. There were no discrepancies observed in this portion of the test. The UUT was then exposed to a number of environments, including thermal vacuum, thermal cycling, random and sine vibration, and mechanical shock. During the thermal environments, the performance of the UUT under load was verified at specified points in the cycles, as described in ATP 20049. In addition, the UUT was bench tested between the two thermal environments. No anomalies were observed during the thermal tests. The vibration and shock tests were performed by East-West Technology Corporation, West Babylon, New York. The UUT was delivered to the lab in a sealed vibration fixture in order to maintain the cleanliness levels required by the SOW. In addition, a three ounce load was attached to the motor shaft. The attachment method of this load caused damage to the shaft and bearing during random vibration of S/N 0003 on April 28, 1995, and is described further in NCR 00168.
Identification and Characterization of Lactic Acid Bacteria in a Commercial Probiotic Culture
MENCONI, Anita; KALLAPURA, Gopala; LATORRE, Juan D.; MORGAN, Marion J.; PUMFORD, Neil R.; HARGIS, Billy M.; TELLEZ, Guillermo
2014-01-01
The aim of the present study was to describe the identification and characterization (physiological properties) of two strains of lactic acid bacteria (LAB 18 and 48) present in a commercial probiotic culture, FloraMax®-B11. Isolates were characterized morphologically, and identified biochemically. In addition, the MIDI System ID, the Biolog ID System, and 16S rRNA sequence analyses for identification of LAB 18 and LAB 48 strains were used to compare the identification results. Tolerance and resistance to acidic pH, high osmotic concentration of NaCl, and bile salts were tested in broth medium. In vitro assessment of antimicrobial activity against enteropathogenic bacteria and susceptibility to antibiotics were also tested. The results obtained in this study showed tolerance of LAB 18 and LAB 48 to pH 3.0, 6.5% NaCl and a high bile salt concentration (0.6%). Both strains evaluated showed in vitro antibacterial activity against Salmonella enterica serovar Enteritidis, Escherichia coli (O157:H7), and Campylobacter jejuni. These are important characteristics of lactic acid bacteria that should be evaluated when selecting strains to be used as probiotics. Antimicrobial activity of these effective isolates may contribute to efficacy, possibly by direct antimicrobial activity in vivo. PMID:24936379
The U.S. Lab is placed in vacuum chamber for leak test
NASA Technical Reports Server (NTRS)
2000-01-01
With the lid of the three-story vacuum chamber in place, a worker on top checks release of the cables. Inside the chamber is the U.S. Lab, a component of the International Space Station. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber for a leak test. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research.
The U.S. Lab is placed in vacuum chamber for leak test
NASA Technical Reports Server (NTRS)
2000-01-01
A worker in the Operations and Checkout Building checks the placement of the lid on the vacuum chamber containing the U.S. Lab, a component of the International Space Station. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber for a leak test. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research.
The U.S. Lab is placed in vacuum chamber for leak test
NASA Technical Reports Server (NTRS)
2000-01-01
Workers in the Operations and Checkout Building check the placement of the lid on the vacuum chamber containing the U.S. Lab, a component of the International Space Station. The 32,000-pound scientific research lab, named Destiny, is the first Space Station element to spend seven days in the renovated vacuum chamber for a leak test. Destiny is scheduled to be launched on Shuttle mission STS-98, the 5A assembly mission, targeted for Jan. 18, 2001. During the mission, the crew will install the Lab in the Space Station during a series of three space walks. The STS-98 mission will provide the Station with science research facilities and expand its power, life support and control capabilities. The U.S. Lab module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research.
[Identification of lactic acid bacteria in commercial yogurt and their antibiotic resistance].
Qin, Yuxuan; Li, Jing; Wang, Qiuya; Gao, Kexin; Zhu, Baoli; Lv, Na
2013-08-04
To identify lactic acid bacteria (LAB) in commercial yogurts and investigate their antibiotic resistance. LABs were cultured from 5 yogurt brands and the isolates were identified at the species level by 16S rRNA sequence. Genotyping was performed by repetitive extragenic palindromic PCR (rep-PCR). The sensitivity to 7 antibiotics was tested for all LAB isolates by Kirby-Bauer paper diffusion (K-B method). Meanwhile, 9 antibiotic resistance genes (ARGs), including erythromycin resistance genes (ermA and ermB) and tetracycline resistance genes (tetM, tetK, tetS, tetQ, tetO, tetL and tetW), were detected by PCR amplification in the identified LAB isolates. The PCR products were confirmed by sequencing. Total 100 LABs were isolated, including 23 Lactobacillus delbrueckii ssp. bulgaricus, 26 Lactobacillus casei, 30 Streptococcus thermophilus, 5 Lactobacillus acidophilus, 6 Lactobacillus plantarum, and 10 Lactobacillus paracasei. The drug susceptibility test shows that all 100 isolates were resistant to gentamicin and streptomycin, 42 isolates were resistant to vancomycin, and on the contrary all were sensitive to cefalexin, erythromycin, tetracycline and oxytetracycline. Moreover, 5 ARGs were found in the 28 sequencing confirmed isolates, ermB gene was detected in 8 isolates, tet K in 4 isolates, tetL in 2 isolates, tetM in 4 isolates, tetO in 2 isolates. erm A, tet S, tet Q and tet W genes were not detected in the isolates. Antibiotic resistance genes were found in 53.57% (15/28) sequenced isolates, 2 -3 antibiotic resistance genes were detected in 4 isolates of L. delbrueckii ssp. bulgaricus. Some LABs were not labeled in commercial yogurt products. Antibiotic resistance genes tend to be found in the starter culture of L. delbrueckii ssp. Bulgaricus and S. thermophilus. All the LAB isolates were sensitive to erythromycin and tetracycline, even though some carried erythromycin and/or tetracycline resistance genes. We proved again that LAB could carry antibiotic resistance gene(s) though it is sensitive to antibiotics.
NASA Glenn Propulsion Systems Lab (PSL) Icing Facility Update
NASA Technical Reports Server (NTRS)
Thomas, Queito P.
2015-01-01
The NASA Glenn Research Center Propulsion Systems Lab (PSL) was recently upgraded to perform engine inlet ice crystal testing in an altitude environment. The system installed 10 spray bars in the inlet plenum for ice crystal generation using 222 spray nozzles. As an altitude test chamber, PSL is capable of simulation of in-flight icing events in a ground test facility. The system was designed to operate at altitudes from 4,000 ft. to 40,000 ft. at Mach numbers up to 0.8M and inlet total temperatures from -60F to +15F.
Game, cloud architecture and outreach for The BIG Bell Test
NASA Astrophysics Data System (ADS)
Abellan, Carlos; Tura, Jordi; Garcia, Marta; Beduini, Federica; Hirschmann, Alina; Pruneri, Valerio; Acin, Antonio; Marti, Maria; Mitchell, Morgan
The BIG Bell test uses the input from the Bellsters, self-selected human participants introducing zeros and ones through an online videogame, to perform a suite of quantum physics experiments. In this talk, we will explore the videogame, the data infrastructure and the outreach efforts of the BIG Bell test collaboration. First, we will discuss how the game was designed so as to eliminate possible feedback mechanisms that could influence people's behavior. Second, we will discuss the cloud architecture design for scalability as well as explain how we sent each individual bit from the users to the labs. Also, and using all the bits collected via the BIG Bell test interface, we will show a data analysis on human randomness, e.g. are younger Bellsters more random than older Bellsters? Finally, we will talk about the outreach and communication efforts of the BIG Bell test collaboration, exploring both the social media campaigns as well as the close interaction with teachers and educators to bring the project into classrooms.
Sakaridis, I; Soultos, N; Dovas, C I; Papavergou, E; Ambrosiadis, I; Koidis, P
2012-02-01
This study was conducted to isolate psychrotrophic lactic acid bacteria (LAB) from chicken carcasses with inhibitory activity against strains of Salmonella spp. and Listeria monocytogenes. A total of 100 broiler samples were examined for the presence of LAB. Ninety-two LAB isolates that showed antimicrobial effects against Salmonella spp. and L. monocytogenes were further analysed to examine their LAB (Gram-positive, catalase negative, oxidase negative) and psychrotrophic characteristics (ability to grow at 7 °C). Fifty isolates were further selected and identified initially using standard biochemical tests in miniature (Micro-kits API CH 50) and then by sequencing of the 16s-23s rRNA gene boundary region (Intergenic Spacer Region). By molecular identification, these isolates were classified into 5 different LAB species: Lactobacillus salivarius, Lactobacillus reuteri, Lactobacillus johnsonii, Pediococcus acidilactici, and Lactobacillus paralimentarius. None of the isolates produced tyramine or histamine. Copyright © 2011 Elsevier Ltd. All rights reserved.
MTR WING A, TRA604, INTERIOR. BASEMENT. DETAIL OF A19 LAB ...
MTR WING A, TRA-604, INTERIOR. BASEMENT. DETAIL OF A-19 LAB AREA ALONG SOUTH WALL. SIGN ON FLOOR DIRECTS WORKERS TO OBTAIN WHOLE BODY FRISK UPON LEAVING AREA. SIGN ON EQUIPMENT IN CENTER OF VIEW REQUESTS WORKERS TO "NOTIFY HEALTH PHYSICS BEFORE WORKING ON THIS SYSTEM." CAMERA FACING SOUTHWEST. INL NEGATIVE NO. HD46-13-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Annual Conference on Human Retrovirus Testing (7th) held in Chicago, IL on March 3-5, 1992
1993-04-05
Ph.D.; Charles Sehable, M.S.; Judith Wethers , M.S.; Judith Wilber, Ph.D. This conference was supported, in part, by a firancial graot from the...Westerman Bill Roberts Judith Wethers , M.S. U Col Chester Roberts, Ph.D. Julianne Wiese Jeanette V Roman Helen Wiprud Gene F Robertson, Ph.D. JoAnn L Yee...RHgmor Thorstensson, Ph.D., National Judith Wethers , M.S., Director of Testing Bacteriological Lab Services. Retrovirology Lab.. New York Ralph
Screening of lactic acid bacteria from vacuum packaged beef for antimicrobial activity
Oliveira, Roseane B. P.; de L. Oliveira, Afonso; Glória, M. Beatriz A.
2008-01-01
The objective of this study was to isolate lactic acid bacteria (LAB) from vacuum packaged beef and to investigate their antagonist activity. LAB mean counts of 5.19 log cfu/cm2 were obtained from five samples of vacuum packaged beef. Two hundred isolates were selected and screened for the inhibitory effect on five ATCC reference Lactobacillus strains. Thirty six isolates showed activity in the agar spot test against at least two of the indicator strains. However, only six cell free supernatants (CFS) from these isolates exhibited activity against the indicator strains using the well-diffusion test and conditions that eliminated the effects of organic acids and hydrogen peroxide. L. acidophilus was the most sensitive indicator tested, whereas L. plantarum and L. fermentum were the most resistant ones. Identification by MIDI system indicated that these LAB isolates were Lactococcus lactis subsp. cremoris, Pediococcus acidilactici, Lactobacillus delbrueckii subsp. bulgaricus and Lactobacillus casei GC subgroup A. The antagonistic factors produced by most of these LAB against L. acidophilus were resistant to heat treatment (100°C for 10 min) and stable over a wide pH range (4.0 to 9.0). These data suggest that these isolates could be used as promising hurdles aiming increased safety and extended shelf life of meat products. PMID:24031232
Estrous cycle and food availability affect feeding induced by amygdala 5-HT receptor blockade.
Parker, Graham C; Bishop, Christopher; Coscina, Donald V
2002-04-01
We have recently reported that bilateral infusions of the 5-HT receptor antagonist metergoline (MET) into the posterior basolateral amygdala (pBLA) elicit feeding in female rats tested at mid-light cycle. The present study was performed to determine whether (1) testing at two different phases of the estrous cycle, and/or (2) the palatability of the food might modify this effect. Subjects were 18 adult females with bilateral pBLA cannulae. Following familiarization with Froot Loops cereal, a within-subjects design tested all animals for 1- and 2-h food intake under 2 Drug (0.3 nmol MET vs. Vehicle), 2 Estrous Cycle (diestrus vs. estrus) and 2 Food (lab chow vs. Froot Loops) conditions. Rats weighed more at diestrus than at proestrus (P<.05) or estrus (P<.005). Multivariate analyses of variance (MANOVAs) revealed a preference for Froot Loops over lab chow (P<.0001). MET increased feeding regardless of food type (P<.0001). Rats ate more Froot Loops (P<.01), but not lab chow, at diestrus vs. estrus. A three-way interaction (P<.05) showed rats ate more during the first hour in estrus than in diestrus to lab chow but not Froot Loops. These data suggest pBLA MET differentially affects feeding over the estrous cycle depending on the palatability of food available.
Shanks, Ryan A; Robertson, Chuck L; Haygood, Christian S; Herdliksa, Anna M; Herdliska, Heather R; Lloyd, Steven A
2017-01-01
Introductory biology courses provide an important opportunity to prepare students for future courses, yet existing cookbook labs, although important in their own way, fail to provide many of the advantages of semester-long research experiences. Engaging, authentic research experiences aid biology students in meeting many learning goals. Therefore, overlaying a research experience onto the existing lab structure allows faculty to overcome barriers involving curricular change. Here we propose a working model for this overlay design in an introductory biology course and detail a means to conduct this lab with minimal increases in student and faculty workloads. Furthermore, we conducted exploratory factor analysis of the Experimental Design Ability Test (EDAT) and uncovered two latent factors which provide valid means to assess this overlay model's ability to increase advanced experimental design abilities. In a pre-test/post-test design, we demonstrate significant increases in both basic and advanced experimental design abilities in an experimental and comparison group. We measured significantly higher gains in advanced experimental design understanding in students in the experimental group. We believe this overlay model and EDAT factor analysis contribute a novel means to conduct and assess the effectiveness of authentic research experiences in an introductory course without major changes to the course curriculum and with minimal increases in faculty and student workloads.
Zatloukal, Jan; Pouska, Jiri; Kletecka, Jakub; Pradl, Richard; Benes, Jan
2016-12-01
The laboratory analysis provides accurate, but time consuming hemoglobin level estimation especially in the emergency setting. The reliability of time-sparing point of care devices (POCT) remains uncertain. We tested two POCT devices accuracy (HemoCue ® 201 + and Gem ® Premier™3000) in routine emergency department workflow. Blood samples taken from patients admitted to the emergency department were analyzed for hemoglobin concentration using a laboratory reference Beckman Coulter LH 750 (HB LAB ), the HemoCue (HB HC ) and the Gem Premier 3000 (HB GEM ). Pairwise comparison for each device and Hb LAB was performed using correlation and the Bland-Altman methods. The reliability of transfusion decision was assessed using three-zone error grid. A total of 292 measurements were performed in 99 patients. Mean hemoglobin level were 115 ± 33, 110 ± 28 and 111 ± 30 g/l for Hb HC , Hb GEM and Hb LAB respectively. A significant correlation was observed for both devices: Hb HC versus Hb LAB (r 2 = 0.93, p < 0.001) and HB GEM versus HB LAB (r 2 = 0.86, p < 0.001). The Bland-Altman method revealed bias of -3.7 g/l (limits of agreement -20.9 to 13.5) for HB HC and HB LAB and 2.5 g/l (-18.6 to 23.5) for HB GEM and HB LAB , which significantly differed between POCT devices (p < 0.001). Using the error grid methodology: 94 or 91 % of values (Hb HC and Hb GEM ) fell in the zone of acceptable difference (A), whereas 0 and 1 % (Hb HC and Hb GEM ) were unacceptable (zone C). The absolute accuracy of tested POCT devices was low though reaching a high level of correlation with laboratory measurement. The results of the Morey´s error grid were unfavorable for both POCT devices.
Bacteria Culture Test: MedlinePlus Lab Test Information
... Information → Bacteria Culture Test URL of this page: https://medlineplus.gov/labtests/bacteriaculturetest.html Bacteria Culture Test ... 2017 Mar 4]; [about 3 screens]. Available from: https://labtestsonline.org/understanding/analytes/sputum-culture/tab/test/ ...
Blood Glucose Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/bloodglucosetest.html Blood Glucose Test To use the sharing features on this page, please enable JavaScript. What is a Blood Glucose Test? A blood glucose test measures the glucose levels ...
Chloride Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/chloridebloodtest.html Chloride Blood Test To use the sharing features on this page, please enable JavaScript. What is a Chloride Blood Test? A chloride blood test measures the amount of ...
Bilirubin Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/bilirubinbloodtest.html Bilirubin Blood Test To use the sharing features on this page, please enable JavaScript. What is a Bilirubin Blood Test? A bilirubin blood test measures the levels of ...
Potassium Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/potassiumbloodtest.html Potassium Blood Test To use the sharing features on this page, please enable JavaScript. What is a Potassium Blood Test? A potassium blood test measures the amount of ...
Prealbumin Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/prealbuminbloodtest.html Prealbumin Blood Test To use the sharing features on this page, please enable JavaScript. What is a prealbumin blood test? A prealbumin blood test measures prealbumin levels in ...
Ferritin Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/ferritinbloodtest.html Ferritin Blood Test To use the sharing features on this page, please enable JavaScript. What is a Ferritin Blood Test? A ferritin blood test measures the level of ...
Definition of avionics concepts for a heavy lift cargo vehicle. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1989-01-01
A cost effective, multiuser simulation, test, and demonstration facility to support the development of avionics systems for future space vehicles is examined. The technology needs and requirements of future Heavy Lift Cargo Vehicles (HLCVs) are analyzed and serve as the basis for sizing of the avionics facility, although the lab is not limited in use to support of HLCVs. Volume 1 provides a summary of the vehicle avionics trade studies, the avionics lab objectives, a summary of the lab's functional requirements and design, physical facility considerations, and cost estimates.
Window Observational Research Facility (WORF)
NASA Technical Reports Server (NTRS)
Pelfrey, Joseph; Sledd, Annette
2007-01-01
This viewgraph document concerns the Window Observational Research Facility (WORF) Rack, a unique facility designed for use with the US Lab Destiny Module window. WORF will provide valuable resources for Earth Science payloads along with serving the purpose of protecting the lab window. The facility can be used for remote sensing instrumentation test and validation in a shirt sleeve environment. WORF will also provide a training platform for crewmembers to do orbital observations of other planetary bodies. WORF payloads will be able to conduct terrestrial studies utilizing the data collected from utilizing WORF and the lab window.
Evaluation and recommendations for work group integration within the Materials and Processes Lab
NASA Technical Reports Server (NTRS)
Farrington, Phillip A.
1992-01-01
The goal of this study was to evaluate and make recommendations for improving the level of integration of several work groups within the Materials and Processes Lab at the Marshall Space Flight Center. This evaluation has uncovered a variety of projects that could improve the efficiency and operation of the work groups as well as the overall integration of the system. In addition, this study provides the foundation for specification of a computer integrated manufacturing test bed environment in the Materials and Processes Lab.
Validation of a Host Response Assay, Septicyte™ LAB, for Discriminating Sepsis from SIRS in the ICU.
Miller Iii, Russell R; Lopansri, Bert K; Burke, John P; Levy, Mitchell; Opal, Steven; Rothman, Richard E; D'Alessio, Franco R; Sidhaye, Venkataramana K; Aggarwal, Neil R; Balk, Robert; Greenberg, Jared A; Yoder, Mark; Patel, Gourang; Gilbert, Emily; Afshar, Majid; Parada, Jorge P; Martin, Greg S; Esper, Annette M; Kempker, Jordan A; Narasimhan, Mangala; Tsegaye, Adey; Hahn, Stella; Mayo, Paul; van der Poll, Tom; Schultz, Marcus J; Scicluna, Brendon P; Klein Klouwenberg, Peter; Rapisarda, Antony; Seldon, Therese A; McHugh, Leo C; Yager, Thomas D; Cermelli, Silvia; Sampson, Dayle; Rothwell, Victoria; Newman, Richard; Bhide, Shruti; Kirk, James T; Navalkar, Krupa; Davis, Roy F; Brandon, Roslyn A; Brandon, Richard B
2018-04-06
A molecular test to distinguish between sepsis and systemic inflammation of non-infectious etiology could potentially have clinical utility. This study evaluated the diagnostic performance of a molecular host response assay (SeptiCyte™ LAB) designed to distinguish between sepsis and non-infectious systemic inflammation in critically ill adults. The study employed a prospective, observational, non-interventional design, and recruited a heterogeneous cohort of adult critical care patients from seven sites in the USA (N=249). An additional group of 198 patients, recruited in the large MARS consortium trial in the Netherlands (clinicaltrials.gov identifier: NCT01905033), was also tested and analyzed, making a grand total of 447 patients in our study. Performance of SeptiCyte™ LAB was compared to retrospective physician diagnosis by a panel of three experts. In receiver operating characteristic curve analysis, SeptiCyte™ LAB had an estimated area under curve of 0.82-0.89 for discriminating sepsis from non-infectious systemic inflammation. The relative likelihood of sepsis versus non-infectious systemic inflammation was found to increase with increasing test score (range 0-10). In a forward logistic regression analysis, the diagnostic performance of the assay was improved only marginally when used in combination with other clinical and laboratory variables including procalcitonin. Performance of the assay was not significantly affected by demographic variables including age, sex, or race/ethnicity. SeptiCyte™ LAB appears to be a promising diagnostic tool to complement physician assessment of infection likelihood in critically ill adult patients with systemic inflammation. Clinical trial registrations available at clinicaltrials.gov, IDs NCT02127502 and NCT01905033.
Microbes in Mascara: Hypothesis-Driven Research in a Nonmajor Biology Lab †
Burleson, Kathryn M.; Martinez-Vaz, Betsy M.
2011-01-01
In this laboratory exercise, students were taught concepts of microbiology and scientific process through an everyday activity — cosmetic use. The students’ goals for the lab were to develop a hypothesis regarding microbial contamination in cosmetics, learn techniques to culture and differentiate microorganisms from cosmetics, and propose best practices in cosmetics use based on their findings. Prior to the lab, students took a pretest to assess their knowledge of scientific hypotheses, microbiology, and cosmetic safety. In the first week, students were introduced to microbiological concepts and methodologies, and cosmetic terminology and safety. Students completed a hypothesis-writing exercise before formulating and testing their own hypotheses regarding cosmetic contamination. Students provided a cosmetic of their own and, in consultation with their lab group, chose one product for testing. Samples were serially diluted and plated on a variety of selective media. In the second week, students analyzed their plates to determine the presence and diversity of microbes and if their hypotheses were supported. Students completed a worksheet of their results and were given a posttest to assess their knowledge. Average test scores improved from 5.2 (pretest) to 7.8 (posttest), with p-values < 0.0001. Seventy-nine percent (79%) of students correctly identified hypotheses that were not falsifiable or lacked variables, and 89% of students improved their scores on questions concerning safe cosmetic use. Ninety-one percent (91%) of students demonstrated increased knowledge of microbial concepts and methods. Based on our results, this lab is an easy, yet effective, way to enhance knowledge of scientific concepts for nonmajors, while maintaining relevance to everyday life. PMID:23653761
Effect of gravity on the caloric stimulation of the inner ear
NASA Technical Reports Server (NTRS)
Kassemi, Mohammad; Deserranno, Dimitri; Oas, John G.
2004-01-01
Robert Barany won the 1914 Nobel Prize in medicine for his convection hypothesis for caloric stimulation. Microgravity caloric tests aboard the 1983 SpaceLab 1 mission produced nystagmus results that contradicted the basic premise of Barany's convection theory. In this paper, we present a fluid structural analysis of the caloric stimulation of the lateral semicircular canal. Direct numerical simulations indicate that on earth, natural convection is the dominant mechanism for endolymphatic flow. However, in the microgravity environment of orbiting spacecraft, where buoyancy effects are mitigated, an expansive convection becomes the sole mechanism for producing endolymph motion and cupular displacement. Transient 1 g and microgravity case studies are presented to delineate the different dynamic behaviors of the 1 g and microgravity endolymphatic flows. The associated fluid-structural interactions are also analyzed based on the time evolution of cupular displacements.
Histone deacetylase inhibitors (HDIs), such as romidepsin, can inhibit the growth of cancer cells and induce their apoptosis by increasing histone acetylation and altering gene expression. Romidepsin has even been approved by the Food and Drug Administration for the treatment of two types of non-Hodgkin lymphoma, cutaneous T cell lymphoma (CTCL) and peripheral T cell lymphoma. But, as Susan Bates, M.D., in CCR’s Medical Oncology Branch, knows firsthand from her work on phase I and II clinical trials testing romidepsin, many cancers are initially resistant or develop resistance to HDIs. Bates, along with Arup Chakraborty, Ph.D., a postdoctoral fellow in her lab, and their colleagues are interested in understanding cellular mechanisms of HDI resistance with the hope of identifying additional pathways that could be targeted to enhance the anticancer efficacy of HDIs.
A Fluid Mechanical Interpretation of Hysteresis in Rhinomanometry
Groß, T. F.; Peters, F.
2011-01-01
A hysteresis effect in the pressure/flow rate relationship of nasal breathing has frequently been observed in clinical tests and in lab investigations. Explanations that have been given in the literature are missing a fluid mechanic storage effect coming into play in reciprocating flows. This effect depends primarily on the way the rhinomanometric measurements are set up and not so much on the nose flow itself. This is to be shown by calculations and experiments. The experiments are carried out with orifices because they can represent nose flow and are often implemented in rhinomanometric equipment as flow gauges. To mimic reality also a 1 : 1 nose model is used. It is shown where the hysteresis comes from and what the key parameters for its prediction are. With these results hysteresis in nasal breathing appears in a new light. PMID:23724249
VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST ...
VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST TOWER VIEW INCLUDES STRUCTURAL DYNAMICS TEST STAND COLD CALIBRATION TEST STAND AND COMPONENTS TEST LAB. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, R.W.; Zimm, C.B.
1994-07-29
This presentation/paper gives an overview of the Oak Ridge National Lab`s collaboration with private industry in developing electric power applications for magnetic refrigeraters which use high temperature superconductors. Highlighted is the lab`s general approach and technical progress towards advancing magnetic refrigeration technology in the 20-80 K range by specifically developing a prototype magnetic cryocooler with could provide 50 W cooling at 40 K. Included is magnet schematics; a listing of the basic components; load points; magnet charge and cooldown; vendor for induction alloying elements; and performance testing. The projects are in collaboration with Astronautics Corporation of America and included aremore » the proposed projects for FY 1995, key personnel, and the fiscal 1994 budgets.« less
Trading Carbon: Can Cookstoves Light the Way (LBNL Science at the Theater)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gadgil, Ashok; Booker, Kayje; Rausch, Adam
2010-09-20
Science at the Theater: Get smart about carbon! Learn how families in Africa, using stoves designed by Berkeley Lab, are at the forefront of global carbon reduction. Ashok Gadgil is the driving force behind the Berkeley-Darfur Cookstove. He is a researcher, inventor, renowned humanitarian, and director of Berkeley Lab's Environmental Energy Technologies Division. Kayje Booker is a Berkeley Lab researcher and UC Berkeley graduate student in ecosystem sciences. She is exploring how carbon markets can serve as catalysts for innovation in technologies for the poor. Adam Rausch is a Berkeley Lab researcher and UC Berkeley graduate student in civil environmentalmore » engineering. He helps to design and test stove designs in Ethiopia and elsewhere.« less
USDA-ARS?s Scientific Manuscript database
The US National institutes of Health-Centers of Excellence for Influenza Research and Surveillance is a research consortium that funds numerous labs worldwide to conduct influenza A surveillance in diverse animal species. There is no harmonization of testing procedures among these labs; therefore an...
Department of Defense In-House RDT and E Activities Report for Fiscal Year 1990
1990-01-01
equipment systems. Advanced personnel and cargo airdrop system. 1FUNCTIONS/EQUIPMENT!/FACI LITIES Biotechnology lab, materials characterization lab...4 Airworthines. Qualification Test Directorate ..... .................................... 5 Armament Rrsearch . Developaent & Eaguiecring Center...1), exploratory development (6.2), advanced development (6.3), engineering development (6.4), management support (6.5), operational systems support
An LED Solar Simulator for Student Labs
ERIC Educational Resources Information Center
González, Manuel I.
2017-01-01
Measuring voltage-current and voltage-power curves of a photovoltaic module is a nice experiment for high school and undergraduate students. In labs where real sunlight is not available this experiment requires a solar simulator. A prototype of a simulator using LED lamps has been manufactured and tested, and a comparison with classical halogen…
An experimental vaccine for mosquito-borne chikungunya is being tested at sites in the Caribbean as part of a phase II clinical trial being managed by the Frederick National Lab. No vaccine or treatment currently exists for the viral disease, which c
Portable Anthrax Testing with Lab-in-a-Pocket
Finley, Melissa; Koskelo, Markku; Edwards, Thayne
2018-05-30
BaDx (Bacillus anthracis Diagnostics) is a lab-in-a-pocket device to sample, sense, and diagnose bacteria that cause anthrax. It accomplishes these tasks in environments with no power, refrigerated storage, or laboratory equipment. BaDx was designed to be used with minimal or no training, and to keep handlers safe.
DOT National Transportation Integrated Search
2013-12-01
The work completed in this project created a series of online lab modules that : transportation professionals could use as a reference to learn how to conduct, how to : interpret, and the applications of geotechnical lab tests used in practice to det...
Impact of Fab Lab Tulsa on Student Self-Efficacy toward STEM Education
ERIC Educational Resources Information Center
Dubriwny, Nicholas; Pritchett, Nathan; Hardesty, Michelle; Hellman, Chan M.
2016-01-01
Student self-confidence is important to any attempt to increase interest and achievement in Science, Technology, Engineering, and Math (STEM) education. This study presents a longitudinal examination of Fab Lab Tulsa's impact on attitude and self-efficacy toward STEM education among middle-school aged students. Paired samples t-test showed a…
Development of an Experimental Literacy Assessment Battery. Final Report.
ERIC Educational Resources Information Center
Sticht, Thomas G.; Beck, Lawrence J.
This report describes the development of a Literacy Assessment Battery (LAB) for determining the relative efficiency with which adults can comprehend language by reading or listening. Development of the LAB included: the tryout with adults of two listening and reading tests designed for children; experimental studies of a decoding task involving…
Irmo High School's Language Arts Lab: A Golden Opportunity.
ERIC Educational Resources Information Center
Ingle, Judith K.
Since 1984, the Language Arts Lab at Irmo High School (Columbia, South Carolina) has provided: (1) remediation in reading and writing to students with low standardized test scores; and (2) assistance to other students in the areas of study skills, college entrance exam preparation, term papers, reading and reading assignments, grammar, and…
Portable Anthrax Testing with Lab-in-a-Pocket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finley, Melissa; Koskelo, Markku; Edwards, Thayne
2014-10-24
BaDx (Bacillus anthracis Diagnostics) is a lab-in-a-pocket device to sample, sense, and diagnose bacteria that cause anthrax. It accomplishes these tasks in environments with no power, refrigerated storage, or laboratory equipment. BaDx was designed to be used with minimal or no training, and to keep handlers safe.
Workers in SSPF monitor Multi-Equipment Interface Test.
NASA Technical Reports Server (NTRS)
2000-01-01
Workers in the Space Station Processing Facility control room check documentation during a Multi-Equipment Interface Test (MEIT) in the U.S. Lab Destiny. Members of the STS-98 crew are taking part in the MEIT checking out some of the equipment in the Lab. During the STS-98 mission, the crew will install the Lab on the station during a series of three space walks. The crew comprises five members: Commander Kenneth D. Cockrell, Pilot Mark L. Polansky, and Mission Specialists Robert L. Curbeam Jr., Thomas D. Jones (Ph.D.) and Marsha S. Ivins. The mission will provide the station with science research facilities and expand its power, life support and control capabilities. The U.S. Laboratory Module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research. The Lab is planned for launch aboard Space Shuttle Atlantis on the sixth ISS flight, currently targeted no earlier than Aug. 19, 2000.
Workers in SSPF monitor Multi-Equipment Interface Test.
NASA Technical Reports Server (NTRS)
2000-01-01
Workers in the Space Station Processing Facility control room monitor computers during a Multi-Equipment Interface Test (MEIT) in the U.S. Lab Destiny. Members of the STS-98 crew are taking part in the MEIT checking out some of the equipment in the Lab. During the STS-98 mission, the crew will install the Lab on the station during a series of three space walks. The crew comprises five members: Commander Kenneth D. Cockrell, Pilot Mark L. Polansky, and Mission Specialists Robert L. Curbeam Jr., Thomas D. Jones (Ph.D.) and Marsha S. Ivins. The mission will provide the station with science research facilities and expand its power, life support and control capabilities. The U.S. Laboratory Module continues a long tradition of microgravity materials research, first conducted by Skylab and later Shuttle and Spacelab missions. Destiny is expected to be a major feature in future research, providing facilities for biotechnology, fluid physics, combustion, and life sciences research. The Lab is planned for launch aboard Space Shuttle Atlantis on the sixth ISS flight, currently targeted no earlier than Aug. 19, 2000.
Swarmie User Manual: A Rover Used for Multi-agent Swarm Research
NASA Technical Reports Server (NTRS)
Montague, Gilbert
2014-01-01
The ability to create multiple functional yet cost effective robots is crucial for conducting swarming robotics research. The Center Innovation Fund (CIF) swarming robotics project is a collaboration among the KSC Granular Mechanics and Regolith Operations (GMRO) group, the University of New Mexico Biological Computation Lab, and the NASA Ames Intelligent Robotics Group (IRG) that uses rovers, dubbed "Swarmies", as test platforms for genetic search algorithms. This fall, I assisted in the development of the software modules used on the Swarmies and created this guide to provide thorough instructions on how to configure your workspace to operate a Swarmie both in simulation and out in the field.
1997-07-18
Jet Propulsion Research Lab (JPL) workers use a borescope to verify the pressure relief device bellow's integrity on a radioisotope thermoelectric generator (RTG) that has been installed on the Cassini spacecraft in the Payload Hazardous Servicing Facility. The activity is part of the mechanical and electrical verification testing of RTGs during prelaunch processing. RTGs use heat from the natural decay of plutonium to generate electrical power. The three RTGs on Cassini will enable the spacecraft to operate far from the Sun where solar power systems are not feasible. They will provide electrical power to Cassini on it seven year trip to the Saturnian system and during its four year mission at Saturn.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gomez, Steven P.; Sobolik, Steve R.; Matteo, Edward N.
This research aims to describe the microannulus region of the cement sheath-steel casing interface in terms of its compressibility and permeability. Here, a wellbore system mock-up was used for lab-scale testing, and was subjected to confining and casing pressures in a pressure vessel while measuring gas flow along the specimen’s axis. The flow was interpreted as the hydraulic aperture of the microannuli. Numerical joint models were used to calculate stress and displacement conditions of the microannulus region, where the mechanical stiffness and hydraulic aperture were altered in response to the imposed stress state and displacement across the joint interface.
Gomez, Steven P.; Sobolik, Steve R.; Matteo, Edward N.; ...
2016-11-16
This research aims to describe the microannulus region of the cement sheath-steel casing interface in terms of its compressibility and permeability. Here, a wellbore system mock-up was used for lab-scale testing, and was subjected to confining and casing pressures in a pressure vessel while measuring gas flow along the specimen’s axis. The flow was interpreted as the hydraulic aperture of the microannuli. Numerical joint models were used to calculate stress and displacement conditions of the microannulus region, where the mechanical stiffness and hydraulic aperture were altered in response to the imposed stress state and displacement across the joint interface.
ExoGeoLab Pilot Project for Landers, Rovers and Instruments
NASA Astrophysics Data System (ADS)
Foing, Bernard
2010-05-01
We have developed a pilot facility with a Robotic Test Bench (ExoGeoLab) and a Mobile Lab Habitat (ExoHab). They can be used to validate concepts and external instruments from partner institutes. The ExoGeoLab research incubator project, has started in the frame of a collaboration between ILEWG (International Lunar Exploration working Group http://sci.esa.int/ilewg), ESTEC, NASA and academic partners, supported by a design and control desk in the European Space Incubator (ESI), as well as infrastructure. ExoGeoLab includes a sequence of technology and research pilot project activities: - Data analysis and interpretation of remote sensing and in-situ data, and merging of multi-scale data sets - Procurement and integration of geophysical, geo-chemical and astrobiological breadboard instruments on a surface station and rovers - Integration of cameras, environment and solar sensors, Visible and near IR spectrometer, Raman spectrometer, sample handling, cooperative rovers - Delivery of a generic small planetary lander demonstrator (ExoGeoLab lander, Sept 2009) as a platform for multi-instruments tests - Research operations and exploitation of ExoGeoLab test bench for various conceptual configurations, and support for definition and design of science surface packages (Moon, Mars, NEOs, outer moons) - Field tests of lander, rovers and instruments in analogue sites (Utah MDRS 2009 & 2010, Eifel volcanic park in Sept 2009, and future campaigns). Co-authors, ILEWG ExoGeoLab & ExoHab Team: B.H. Foing(1,11)*#, C. Stoker(2,11)*, P. Ehrenfreund(10,11), L. Boche-Sauvan(1,11)*, L. Wendt(8)*, C. Gross(8, 11)*, C. Thiel(9)*, S. Peters(1,6)*, A. Borst(1,6)*, J. Zavaleta(2)*, P. Sarrazin(2)*, D. Blake(2), J. Page(1,4,11), V. Pletser(5,11)*, E. Monaghan(1)*, P. Mahapatra(1)#, A. Noroozi(3), P. Giannopoulos(1,11) , A. Calzada(1,6,11), R. Walker(7), T. Zegers(1, 15) #, G. Groemer(12)# , W. Stumptner(12)#, B. Foing(2,5), J. K. Blom(3)#, A. Perrin(14)#, M. Mikolajczak(14)#, S. Chevrier(14)#, S. Direito(6)#, S. Voute (15)#, A. Olmedo-Soler(17)#, T. E. Zegers(1, 15)#, D. Scheer(12)#, K. Bickert(12)#, D. Schildhammer(12)#, B. Jantscher(1, 11, 12)#, MECA Team(6)#, ExoGeoLab ILEWG ExoHab teams(1,4,11) EuroGeoMars team(1,4,5); 1)ESTEC/SRE-S Postbus 299, 2200 AG Noordwijk, NL, 2)NASA Ames , 3)Delft TU , 4)ESTEC TEC Technology Dir., 5)ESTEC HSF Human Spaceflight, 6)VU Amsterdam, 7)ESTEC Education Office, 8)FU Berlin, 9)Max Planck Goettingen, 10)Leiden/GWU , 11)ILEWG ExoHab Team, 12)Austrian Space Forum (OEWF Innsbruck); 14) Ecole de l'Air, Salons de Provence, 15) Utrecht U., 16) MECA Team, 17) Olmedo Knowledge Systems S.L.; * EuroGeoMars Utah crew , # ILEWG Eifel crew, EuroMoonMars/DOMMEX Utah crew.
NASA Astrophysics Data System (ADS)
Cobb, Bethany E.
2018-01-01
Since 2013, the Physics Department at GWU has used student-centered active learning in the introductory astronomy course “Introduction to the Cosmos.” Class time is spent in groups on questions, math problems, and hands-on activities, with multiple instructors circulating to answer questions and engage with the students. The students have responded positively to this active-learning. Unfortunately, in transitioning to active-learning there was no time to rewrite the labs. Very quickly, the contrast between the dynamic classroom and the traditional labs became apparent. The labs were almost uniformly “cookie-cutter” in that the procedure and analysis were specified step-by-step and there was just one right answer. Students rightly criticized the labs for lacking a clear purpose and including busy-work. Furthermore, this class fulfills the GWU scientific reasoning general education requirement and thus includes learning objectives related to understanding the scientific method, testing hypotheses with data, and considering uncertainty – but the traditional labs did not require these skills. I set out to rejuvenate the lab sequence by writing new inquiry labs based on both topic-specific and scientific reasoning learning objectives. While inquiry labs can be challenging for the students, as they require active thinking and creativity, these labs engage the students more thoroughly in the scientific process. In these new labs, whenever possible, I include real astronomical data and ask the students to use digital tools (SDSS SkyServer, SOHO archive) as if they are real astronomers. To allow students to easily plot, manipulate and analyze data, I built “smart” Excel files using formulas, dropdown menus and macros. The labs are now much more authentic and thought-provoking. Whenever possible, students independently develop questions, hypotheses, and procedures and the scientific method is “scaffolded” over the semester by providing more guidance in the early labs and more independence later on. Finally, in every lab, students must identify and reflect on sources of error. These labs are more challenging for the instructors to run and to grade, but they are much more satisfying when it comes to student learning.
Valx: A system for extracting and structuring numeric lab test comparison statements from text
Hao, Tianyong; Liu, Hongfang; Weng, Chunhua
2017-01-01
Objectives To develop an automated method for extracting and structuring numeric lab test comparison statements from text and evaluate the method using clinical trial eligibility criteria text. Methods Leveraging semantic knowledge from the Unified Medical Language System (UMLS) and domain knowledge acquired from the Internet, Valx takes 7 steps to extract and normalize numeric lab test expressions: 1) text preprocessing, 2) numeric, unit, and comparison operator extraction, 3) variable identification using hybrid knowledge, 4) variable - numeric association, 5) context-based association filtering, 6) measurement unit normalization, and 7) heuristic rule-based comparison statements verification. Our reference standard was the consensus-based annotation among three raters for all comparison statements for two variables, i.e., HbA1c and glucose, identified from all of Type 1 and Type 2 diabetes trials in ClinicalTrials.gov. Results The precision, recall, and F-measure for structuring HbA1c comparison statements were 99.6%, 98.1%, 98.8% for Type 1 diabetes trials, and 98.8%, 96.9%, 97.8% for Type 2 Diabetes trials, respectively. The precision, recall, and F-measure for structuring glucose comparison statements were 97.3%, 94.8%, 96.1% for Type 1 diabetes trials, and 92.3%, 92.3%, 92.3% for Type 2 diabetes trials, respectively. Conclusions Valx is effective at extracting and structuring free-text lab test comparison statements in clinical trial summaries. Future studies are warranted to test its generalizability beyond eligibility criteria text. The open-source Valx enables its further evaluation and continued improvement among the collaborative scientific community. PMID:26940748
Valx: A System for Extracting and Structuring Numeric Lab Test Comparison Statements from Text.
Hao, Tianyong; Liu, Hongfang; Weng, Chunhua
2016-05-17
To develop an automated method for extracting and structuring numeric lab test comparison statements from text and evaluate the method using clinical trial eligibility criteria text. Leveraging semantic knowledge from the Unified Medical Language System (UMLS) and domain knowledge acquired from the Internet, Valx takes seven steps to extract and normalize numeric lab test expressions: 1) text preprocessing, 2) numeric, unit, and comparison operator extraction, 3) variable identification using hybrid knowledge, 4) variable - numeric association, 5) context-based association filtering, 6) measurement unit normalization, and 7) heuristic rule-based comparison statements verification. Our reference standard was the consensus-based annotation among three raters for all comparison statements for two variables, i.e., HbA1c and glucose, identified from all of Type 1 and Type 2 diabetes trials in ClinicalTrials.gov. The precision, recall, and F-measure for structuring HbA1c comparison statements were 99.6%, 98.1%, 98.8% for Type 1 diabetes trials, and 98.8%, 96.9%, 97.8% for Type 2 diabetes trials, respectively. The precision, recall, and F-measure for structuring glucose comparison statements were 97.3%, 94.8%, 96.1% for Type 1 diabetes trials, and 92.3%, 92.3%, 92.3% for Type 2 diabetes trials, respectively. Valx is effective at extracting and structuring free-text lab test comparison statements in clinical trial summaries. Future studies are warranted to test its generalizability beyond eligibility criteria text. The open-source Valx enables its further evaluation and continued improvement among the collaborative scientific community.
My Green Car: The Adventure Begins (Ep. 1) â DOE Lab-Corps Video Series
Saxena, Samveg; Shah, Nihar; Hansen, Dana
2018-06-12
One key difference between a great technology that stays in the lab and one that reaches the marketplace is customer interest. In Episode 1, the Labâs MyGreenCar team gets ready to step outside the lab and test their technologyâs value to consumers in a scientific way. What makes a new technology compelling enough to transition out of the lab and become a consumer product? Thatâs the question Berkeley Lab researchers Samveg Saxena, Nihar Shah, and Dana Hansen plus industry mentor Russell Carrington set out to answer for MyGreenCar, an app providing personalized fuel economy or electric vehicle range estimates for consumers researching new cars. DOEâs Lab-Corps program offered the technology team some answers. The EERE-funded program, based on the National Science Foundationâs I-Corps⢠model for entrepreneurial training, provides tools and training to move energy-related inventions to the marketplace. During Lab-Corpâs intensive six-week session, technology teams interview 100 customer and value chain members to discover which potential products based on their technologies will have significant market pull. A six video series follows the MyGreenCar teamâs Lab-Corps experience, from pre-training preparation with the Labâs Innovation and Partnerships Office through the ups and downs of the customer discovery process. Will the app make it to the marketplace? Youâll just have to watch.
Object Creation and Human Factors Evaluation for Virtual Environments
NASA Technical Reports Server (NTRS)
Lindsey, Patricia F.
1998-01-01
The main objective of this project is to provide test objects for simulated environments utilized by the recently established Army/NASA Virtual Innovations Lab (ANVIL) at Marshall Space Flight Center, Huntsville, Al. The objective of the ANVIL lab is to provide virtual reality (VR) models and environments and to provide visualization and manipulation methods for the purpose of training and testing. Visualization equipment used in the ANVIL lab includes head-mounted and boom-mounted immersive virtual reality display devices. Objects in the environment are manipulated using data glove, hand controller, or mouse. These simulated objects are solid or surfaced three dimensional models. They may be viewed or manipulated from any location within the environment and may be viewed on-screen or via immersive VR. The objects are created using various CAD modeling packages and are converted into the virtual environment using dVise. This enables the object or environment to be viewed from any angle or distance for training or testing purposes.
Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...
Cortisol Test: MedlinePlus Lab Test Information
... page: https://medlineplus.gov/labtests/cortisoltest.html Cortisol Test To use the sharing features on this page, please enable JavaScript. What is a Cortisol Test? Cortisol is a hormone that affects almost every ...
Lipase Test: MedlinePlus Lab Test Information
... page: https://medlineplus.gov/labtests/lipasetest.html Lipase Test To use the sharing features on this page, please enable JavaScript. What is a lipase test? Lipase is a type of protein made by ...
AST Test: MedlinePlus Lab Test Information
... page: https://medlineplus.gov/labtests/asttest.html AST Test To use the sharing features on this page, please enable JavaScript. What is an AST Test? AST (aspartate aminotransferase) is an enzyme that is ...
Chlamydia Test: MedlinePlus Lab Test Information
... page: https://medlineplus.gov/labtests/chlamydiatest.html Chlamydia Test To use the sharing features on this page, please enable JavaScript. What is a Chlamydia Test? Chlamydia is one of the most common sexually ...
... Some labs use different measurements or test different samples. Talk to your provider about the meaning of your ... saliva test. BLOOD TEST Veins and arteries vary in size from one person to another and from one side of ...
Use of Facebook in Teaching: A Case Study of a Fluid Mechanics Course
ERIC Educational Resources Information Center
Mandavgane, Sachin A.
2016-01-01
Fluid mechanics (FM) is a core course of the chemical, mechanical, civil, and aerospace engineering programs. Students have both theory and practical classes in FM. The general expectation is that students should be able to demonstrate the fundamentals learnt in theory and get hands-on experience during the lab course. In this regard, students…
NASA Astrophysics Data System (ADS)
Chambers, Timothy
This dissertation presents the results of an experiment that measured the learning outcomes associated with three different pedagogical approaches to introductory physics labs. These three pedagogical approaches presented students with the same apparatus and covered the same physics content, but used different lab manuals to guide students through distinct cognitive processes in conducting their laboratory investigations. We administered post-tests containing multiple-choice conceptual questions and free-response quantitative problems one week after students completed these laboratory investigations. In addition, we collected data from the laboratory practical exam taken by students at the end of the semester. Using these data sets, we compared the learning outcomes for the three curricula in three dimensions of ability: conceptual understanding, quantitative problem-solving skill, and laboratory skills. Our three pedagogical approaches are as follows. Guided labs lead students through their investigations via a combination of Socratic-style questioning and direct instruction, while students record their data and answers to written questions in the manual during the experiment. Traditional labs provide detailed written instructions, which students follow to complete the lab objectives. Open labs provide students with a set of apparatus and a question to be answered, and leave students to devise and execute an experiment to answer the question. In general, we find that students performing Guided labs perform better on some conceptual assessment items, and that students performing Open labs perform significantly better on experimental tasks. Combining a classical test theory analysis of post-test results with in-lab classroom observations allows us to identify individual components of the laboratory manuals and investigations that are likely to have influenced the observed differences in learning outcomes associated with the different pedagogical approaches. Due to the novel nature of this research and the large number of item-level results we produced, we recommend additional research to determine the reproducibility of our results. Analyzing the data with item response theory yields additional information about the performance of our students on both conceptual questions and quantitative problems. We find that performing lab activities on a topic does lead to better-than-expected performance on some conceptual questions regardless of pedagogical approach, but that this acquired conceptual understanding is strongly context-dependent. The results also suggest that a single "Newtonian reasoning ability" is inadequate to explain student response patterns to items from the Force Concept Inventory. We develop a framework for applying polytomous item response theory to the analysis of quantitative free-response problems and for analyzing how features of student solutions are influenced by problem-solving ability. Patterns in how students at different abilities approach our post-test problems are revealed, and we find hints as to how features of a free-response problem influence its item parameters. The item-response theory framework we develop provides a foundation for future development of quantitative free-response research instruments. Chapter 1 of the dissertation presents a brief history of physics education research and motivates the present study. Chapter 2 describes our experimental methodology and discusses the treatments applied to students and the instruments used to measure their learning. Chapter 3 provides an introduction to the statistical and analytical methods used in our data analysis. Chapter 4 presents the full data set, analyzed using both classical test theory and item response theory. Chapter 5 contains a discussion of the implications of our results and a data-driven analysis of our experimental methods. Chapter 6 describes the importance of this work to the field and discusses the relevance of our research to curriculum development and to future work in physics education research.
Corbel, Vincent; Raymond, Michel; Chandre, Fabrice; Darriet, Frédéric; Hougard, Jean-Marc
2004-04-01
The efficacy of insecticide mixtures of permethrin (pyrethroid) and propoxur (carbamate) was tested by larval bioassays on two strains of Culex quinquefasciatus (Say), one resistant to pyrethroids and the other resistant to carbamates. The method consisted in combining one insecticide at the highest concentration causing no mortality (LC0) with increasing concentrations of the second one. The concentration-mortality regression lines were determined for permethrin and propoxur alone and in combination, and synergism ratios (SR) were calculated in order to determine the magnitude of an increase or decrease in efficacy with use of the mixtures. With the pyrethroid-resistant strain (BK-PER), the results showed that propoxur at LC0 significantly enhanced the insecticidal activity of permethrin (SR50 = 1.54), especially on the upper range of the concentration-mortality regression. Conversely, when permethrin at LC0 was tested with propoxur against the carbamate resistant strain (R-LAB), an antagonistic effect was observed (SR50 = 0.67). With the BK-PER strain, an increased oxidative detoxification (MFO) appeared to be the main mechanism responsible for the synergistic interaction. Nevertheless, antagonism in the R-LAB strain is probably due to a physiological perturbation implying different target sites for pyrethroid (ie sodium channel) and carbamate insecticides [ie acetylcholinesterase (EC 3.3.3.7) and choline acetyltransferase (EC 2.3.1.6)].
Dess, Nancy K.; Madkins, Chardonnay D.; Geary, Bree A.; Chapman, Clinton D.
2013-01-01
Naïve humans and rats voluntarily consume little ethanol at concentrations above ~6% due to its aversive flavor. Developing procedures that boost intake of ethanol or ethanol-paired flavors facilitates research on neural mechanisms of ethanol-associated behaviors and helps identify variables that modulate ethanol intake outside of the lab. The present study explored the impact on consumption of ethanol and ethanol-paired flavors of nutritionally significant parametric variations: ethanol vehicle (gelatin or solution, with or without polycose); ethanol concentration (4% or 10%); and feeding status (chow deprived or ad lib.) during flavor conditioning and flavor preference testing. Individual differences were modeled by testing rats of lines selectively bred for high (HiS) or low (LoS) saccharin intake. A previously reported preference for ethanol-paired flavors was replicated when ethanol had been drunk during conditioning. However, indifference or aversion to ethanol-paired flavors generally obtained when ethanol had been eaten in gelatin during conditioning, regardless of ethanol concentration, feeding status, or caloric value of the vehicle. Modest sex and line variations occurred. Engaging different behavioral systems when eating gelatin, rather than drinking solution, may account for these findings. Implications for parameter selection in future neurobiological research and for understanding conditions that influence ethanol intake outside of the lab are discussed. PMID:24284614
NASA Technical Reports Server (NTRS)
Ballesteros, Erik Nicholas
2014-01-01
Understanding the surface and atmosphere of Mars is critical to current and future development of exploration systems. Dealing with the Martian regolith-the top layer of soil-remains a significant challenge, and much research is still needed. Addressing this need, the Cryogenics Test Lab and Granular Mechanics and Regolith Operations Lab at NASA's Kennedy Space Center are partnering to develop an apparatus that utilizes simulated Martian regolith in an analogous atmospheric environment to gather data about how the material behaves when exposed to water vapor. Martian surface temperatures range from 128 K (-145 C) to 308 K (35 C), and the average pressure is approximately 4.5 Torr; which presents an environment where water can potentially exist in vapor, solid or liquid form. And based on prior Mars missions such as the Phoenix Lander, it is known that water-ice exists just below the surface. This test apparatus will attempt to recreate the conditions that contributed to the Martian ice deposits by exposing a sample to water vapor at low pressure and temperature; thereby forming ice inside the simulant via diffusion. From this, we can better understand the properties and behavior of the regolith, and have more knowledge concerning its ability to store water-and subsequently, how to dig up and extract that water-which will be crucial to sample gathering when the first manned Mars mission takes place.
Oscar Marin and the Creation of a Cognitive Neuropsychology Laboratory.
Posner, Michael I
2015-09-01
During the 1980s, the Cognitive Neuropsychology Laboratory at Good Samaritan Hospital, Portland, Oregon, made important strides in the study of brain injury. Created and headed by Oscar Marin and the author, in affiliation with the University of Oregon, the lab brought together students, fellows, and visiting experts in neurology, psychology, psychiatry, neuropsychology, neurobiology, neurophysiology, and computation. Their patient-focused collaborations produced groundbreaking research in language and its disorders, bradyphrenia, neglect, cerebellar function and impairment, and the psychology of music. The lab hosted the meeting that they documented in the influential 1985 book Attention and Performance XI: Mechanisms of Attention. The lab's members have gone on to lead distinguished careers and continue making major contributions to cognitive neuroscience.
Lab-on-a-chip technologies for genodermatoses: Recent progress and future perspectives.
Hongzhou, Cui; Shuping, Guo; Wenju, Wang; Li, Li; Lulu, Wei; Linjun, Deng; Jingmin, Li; Xiaoli, Ren; Li, Bai
2017-02-01
In recent years, molecular biology has proven to be a great asset in our understanding of mechanisms in genodermatoses. However, bench to bedside translation research lags far behind. Advances in lab-on-a-chip technologies enabled programmable, reconfigurable, and scalable manipulation of a variety of laboratory procedures. Sample preparation, microfluidic reactions, and continuous monitoring systems can be integrated on a small chip. These advantages have attracted attention in various fields of clinical application including diagnosis of inherited skin diseases. This review lists an overview of the underlying genes and mutations and describes prospective application of lab-on-a-chip technologies as solutions to challenges for point-of-care genodematoses diagnosis. Copyright © 2016. Published by Elsevier B.V.
Twists and turns--How we stepped into and had fun in the "boring" lipid field.
Han, Min
2015-11-01
Compared to proteins and RNAs, functional specificities associated with structural variations in fatty acids and lipids have been greatly underexplored. This review describes how our lab naively started to work on lipids 14 years ago, and how we have gradually overcome obstacles to address some interesting biological questions by combining genetics with biochemical methods on the nematode Caenorhabditis elegans. Our studies have revealed lipid variants and their metabolic pathways, in specific tissues, impact development and behaviors by regulating specific signaling events. The review also discusses the general research approach, style of lab management, and funding mechanisms that have facilitated the frequent research direction changes in the lab, including the journey into the lipid field.
Calcium in Urine Test: MedlinePlus Lab Test Information
... medlineplus.gov/labtests/calciuminurinetest.html Calcium in Urine Test To use the sharing features on this page, ... enable JavaScript. What is a Calcium in Urine Test? A calcium in urine test measures the amount ...
Lipoprotein (a) Blood Test: MedlinePlus Lab Test Information
... medlineplus.gov/labtests/lipoproteinabloodtest.html Lipoprotein (a) Blood Test To use the sharing features on this page, ... enable JavaScript. What is a Lipoprotein (a) Blood Test? A lipoprotein (a) test measures the level of ...
ANA (Antinuclear Antibody) Test: MedlinePlus Lab Test Information
... medlineplus.gov/labtests/anaantinuclearantibodytest.html ANA (Antinuclear Antibody) Test To use the sharing features on this page, ... enable JavaScript. What is an ANA (Antinuclear Antibody) Test? An ANA test looks for antinuclear antibodies in ...
Anion Gap Blood Test: MedlinePlus Lab Test Information
... medlineplus.gov/labtests/aniongapbloodtest.html Anion Gap Blood Test To use the sharing features on this page, ... enable JavaScript. What is an Anion Gap Blood Test? An anion gap blood test is a way ...
Prostate-Specific Antigen (PSA) Test: MedlinePlus Lab Test Information
... gov/labtests/prostatespecificantigenpsatest.html Prostate-Specific Antigen (PSA) Test To use the sharing features on this page, ... JavaScript. What is a prostate-specific antigen (PSA) test? A prostate-specific antigen (PSA) test measures the ...
Fecal Occult Blood Test (FOBT): MedlinePlus Lab Test Information
... medlineplus.gov/labtests/fecaloccultbloodtestfobt.html Fecal Occult Blood Test (FOBT) To use the sharing features on this ... enable JavaScript. What is a Fecal Occult Blood Test? A fecal occult blood test (FOBT) looks at ...
Monitoring CO2 invasion processes at the pore scale using geological labs on chip.
Morais, S; Liu, N; Diouf, A; Bernard, D; Lecoutre, C; Garrabos, Y; Marre, S
2016-09-21
In order to investigate at the pore scale the mechanisms involved during CO2 injection in a water saturated pore network, a series of displacement experiments is reported using high pressure micromodels (geological labs on chip - GLoCs) working under real geological conditions (25 < T (°C) < 75 and 4.5 < p (MPa) < 8). The experiments were focused on the influence of three experimental parameters: (i) the p, T conditions, (ii) the injection flow rates and (iii) the pore network characteristics. By using on-chip optical characterization and imaging approaches, the CO2 saturation curves as a function of either time or the number of pore volume injected were determined. Three main mechanisms were observed during CO2 injection, namely, invasion, percolation and drying, which are discussed in this paper. Interestingly, besides conventional mechanisms, two counterintuitive situations were observed during the invasion and drying processes.
Enhancing pre-service physics teachers' creative thinking skills through HOT lab design
NASA Astrophysics Data System (ADS)
Malik, Adam; Setiawan, Agus; Suhandi, Andi; Permanasari, Anna
2017-08-01
A research on the implementation of HOT (Higher Order Thinking) Laboratory has been carried out. This research is aimed to compare increasing of creative thinking skills of pre-service physics teachers who receive physics lesson with HOT Lab and with verification lab for the topic of electric circuit. This research used a quasi-experiment methods with control group pretest-posttest design. The subject of the research is 40 Physics Education pre-service physics teachers of UIN Sunan Gunung Djati Bandung. Research samples were selected by class random sampling technique. Data on pre-service physics teachers' creative thinking skills were collected using test of creative thinking skills in the form of essay. The results of the research reveal that average of N-gain of creative thinking skills are <0,69> for pre-service physics teachers who received lesson with HOT Lab design and <0,39> for pre-service physics teachers who received lesson with verification lab, respectively. Therefore, we conclude that application of HOT Lab design is more effective to increase creative thinking skills in the lesson of electric circuit.
LabVIEW Interface for PCI-SpaceWire Interface Card
NASA Technical Reports Server (NTRS)
Lux, James; Loya, Frank; Bachmann, Alex
2005-01-01
This software provides a LabView interface to the NT drivers for the PCISpaceWire card, which is a peripheral component interface (PCI) bus interface that conforms to the IEEE-1355/ SpaceWire standard. As SpaceWire grows in popularity, the ability to use SpaceWire links within LabVIEW will be important to electronic ground support equipment vendors. In addition, there is a need for a high-level LabVIEW interface to the low-level device- driver software supplied with the card. The LabVIEW virtual instrument (VI) provides graphical interfaces to support all (1) SpaceWire link functions, including message handling and routing; (2) monitoring as a passive tap using specialized hardware; and (3) low-level access to satellite mission-control subsystem functions. The software is supplied in a zip file that contains LabVIEW VI files, which provide various functions of the PCI-SpaceWire card, as well as higher-link-level functions. The VIs are suitably named according to the matching function names in the driver manual. A number of test programs also are provided to exercise various functions.
Assessment of Student Learning in Modern Experiments in the Introductory Calculus-Based Physics Labs
NASA Astrophysics Data System (ADS)
Woodahl, Brian; Ross, John; Lang, Sarah; Scott, Derek; Williams, Jeremy
2010-10-01
With the advent of newer microelectronic sensors it's now possible to modernize introductory physics labs with the latest technology and this may allow for enhanced student participation/learning in the experiments. For example, force plate sensors can digitize and record the force on an object, later it can be analyzed in detail (i.e, impulse from force vs. time). Small 3-axis accelerometers can record 3-dim, time-dependent acceleration of objects undergoing complex motions. These devices are small, fairly easy to use, and importantly, are likely to enhance student learning by ``personalizing'' data collection, i.e. making the student an active part of the measurement process and no longer a passive observer. To assess whether these new high-tech labs enhance student learning, we have implemented pre- and post- test sessions to measure the effectiveness of student learning. Four of our calculus-based lab sections were used: Two sections the control group, using the previous ``old technology'' labs, the other two, the experimental group, using the new ``modern technology'' labs. Initial returns of assessment data offer some surprising insight.
Using SDO Data in the Classroom to Do Real Science -- A Community College Laboratory Investigation
NASA Astrophysics Data System (ADS)
Dave, T. A.; Hildreth, S.; Lee, S.; Scherrer, D. K.
2013-12-01
The incredible accessibility of extremely high spatial and temporal resolution data from the Solar Dynamics Observatory creates an opportunity for students to do almost real-time investigation in an Astronomy Lab. We are developing a short series of laboratory exercises using SDO data, targeted for Community College students in an introductory lab class, extendable to high school and university students. The labs initially lead students to explore what SDO can do, online, through existing SDO video clips taken on specific dates. Students then investigate solar events using the Heliophysics Events Knowledgebase (HEK), and make their own online movies of events, to discuss and share with classmates. Finally, students can investigate specific events and areas, selecting specific dates, locations, wavelength regions, and time cadences to create and gather their own SDO datasets for more detailed investigation. In exploring the Sun using actual data, students actually do real science. We are in the process of beta testing the sequence of labs, and are seeking interested community college, university, and high school astronomy lab teachers who might consider trying the labs themselves.
Atmospheric simulation using a liquid crystal wavefront-controlling device
NASA Astrophysics Data System (ADS)
Brooks, Matthew R.; Goda, Matthew E.
2004-10-01
Test and evaluation of laser warning devices is important due to the increased use of laser devices in aerial applications. This research consists of an atmospheric aberrating system to enable in-lab testing of various detectors and sensors. This system employs laser light at 632.8nm from a Helium-Neon source and a spatial light modulator (SLM) to cause phase changes using a birefringent liquid crystal material. Measuring outgoing radiation from the SLM using a CCD targetboard and Shack-Hartmann wavefront sensor reveals an acceptable resemblance of system output to expected atmospheric theory. Over three turbulence scenarios, an error analysis reveals that turbulence data matches theory. A wave optics computer simulation is created analogous to the lab-bench design. Phase data, intensity data, and a computer simulation affirm lab-bench results so that the aberrating SLM system can be operated confidently.
Blank, Fidela S J; Miller, Moses; Nichols, James; Smithline, Howard; Crabb, Gillian; Pekow, Penelope
2009-04-01
The purpose of this study is to compare blood glucose levels measured by a point of care (POC) device to laboratory measurement using the same sample venous blood from patients with suspected diabetic ketoacidosis (DKA). A descriptive correlational design was used for this IRB-approved quality assurance project. The study site was the 50-bed BMC emergency department (ED) which has an annual census of over 100,000 patient visits. The convenience sample consisted of 54 blood samples from suspected DKA patients with orders for hourly blood draws for glucose measurement. Spearman correlations of the glucose POC values, reference lab values, and differences between the two, were evaluated. A chi-square test was used to evaluate the association between the acidosis status and FDA acceptability of POC values. Patient age range was 10-86 years; 63% were females; 46% had a final diagnosis of DKA. POC values underestimated glucose levels 93% of the time. There was a high correlation between the lab value and the magnitude of the difference, (lab minus POC value) indicating that the higher the true glucose value, the greater the difference between the lab and the POC value. A chi-square test showed no overall association between acidosis and FDA-acceptability. The POC values underestimated lab reported glucose levels in 50 of 54 cases even with the use of same venous sample sent to the lab, which make it highly unreliable for use in monitoring suspected DKA patients.
Xie, Wen; Liu, Yang; Wang, Shaoli; Wu, Qingjun; Pan, Huipeng; Yang, Xin; Guo, Litao; Zhang, Youjun
2014-01-01
Abstract Whitefly biotypes B and Q are the two most damaging members of the Bemisia tabaci (Hemiptera: Aleyrodidae) species complex. Control of B. tabaci (and especially of Q) has been impaired by resistance to commonly used insecticides. To find new insecticides for B. tabaci management in China, we investigated the sensitivity of eggs, larvae, and adults of laboratory strains of B and Q (named Lab-B and Lab-Q) and field strains of Q to several insecticides. For eggs, larvae, and adults of B. tabaci and for six insecticides (cyantraniliprole, chlorantraniliprole, pyriproxyfen, buprofezin, acetamiprid, and thiamethoxam), LC 50 values were higher for Lab-Q than for Lab-B; avermectin LC 50 values, however, were low for adults of both Lab-Q and Lab-B. Based on the laboratory results, insecticides were selected to test against eggs, larvae, and adults of four field strains of B. tabaci Q. Although the field strains differed in their sensitivity to the insecticides, the eggs and larvae of all strains were highly sensitive to cyantraniliprole, and the adults of all strains were highly sensitive to avermectin. The eggs, larvae, and adults of B. tabaci Q were generally more resistant than those of B. tabaci B to the tested insecticides. B. tabaci Q eggs and larvae were sensitive to cyantraniliprole and pyriproxyfen, whereas B. tabaci Q adults were sensitive to avermectin. Field trials should be conducted with cyantraniliprole, pyriproxyfen, and avermectin for control of B. tabaci Q and B in China. PMID:25434040
Fluid-structural dynamics of ground-based and microgravity caloric tests
NASA Technical Reports Server (NTRS)
Kassemi, M.; Oas, J. G.; Deserranno, Dimitri
2005-01-01
Microgravity caloric tests aboard the 1983 SpaceLab1 mission produced nystagmus results with an intensity comparable to those elicited during post- and pre- flight tests, thus contradicting the basic premise of Barany's convection hypothesis for caloric stimulation. In this work, we present a dynamic fluid structural analysis of the caloric stimulation of the lateral semicircular canal based on two simultaneous driving forces for the endolymphatic flow: natural convection driven by the temperature-dependent density variation in the bulk fluid and expansive convection caused by direct volumetric displacement of the endolymph during the thermal irrigation. Direct numerical simulations indicate that on earth, the natural convection mechanism is dominant. But in the microgravity environment of orbiting spacecraft, where buoyancy effects are mitigated, expansive convection becomes the sole mechanism for producing cupular displacement. A series of transient 1 g and microgravity case studies are presented to delineate the differences between the dynamics of the 1 g and microgravity endolymphatic flows. The impact of these different flow dynamics on the endolymph-cupula fluid-structural interactions is also analyzed based on the time evolutions of cupular displacement and velocity and the transcupular pressure differences.
Fluid-structural dynamics of ground-based and microgravity caloric tests.
Kassemi, M; Oas, J G; Deserranno, Dimitri
2005-01-01
Microgravity caloric tests aboard the 1983 SpaceLab1 mission produced nystagmus results with an intensity comparable to those elicited during post- and pre- flight tests, thus contradicting the basic premise of Barany's convection hypothesis for caloric stimulation. In this work, we present a dynamic fluid structural analysis of the caloric stimulation of the lateral semicircular canal based on two simultaneous driving forces for the endolymphatic flow: natural convection driven by the temperature-dependent density variation in the bulk fluid and expansive convection caused by direct volumetric displacement of the endolymph during the thermal irrigation. Direct numerical simulations indicate that on earth, the natural convection mechanism is dominant. But in the microgravity environment of orbiting spacecraft, where buoyancy effects are mitigated, expansive convection becomes the sole mechanism for producing cupular displacement. A series of transient 1 g and microgravity case studies are presented to delineate the differences between the dynamics of the 1 g and microgravity endolymphatic flows. The impact of these different flow dynamics on the endolymph-cupula fluid-structural interactions is also analyzed based on the time evolutions of cupular displacement and velocity and the transcupular pressure differences.
Bone Marrow Test: MedlinePlus Lab Test Information
... this page: https://medlineplus.gov/labtests/bonemarrowtest.html Bone Marrow Test To use the sharing features on this page, please enable JavaScript. What Are Bone Marrow Tests? Bone marrow is a soft, spongy ...
Albumin Blood Test: MedlinePlus Lab Test Information
... Information → Albumin Blood Test URL of this page: https://medlineplus.gov/labtests/albuminbloodtest.html Albumin Blood Test ... 2017 Apr 26]; [about 3 screens]. Available from: https://www.liverfoundation.org/for-patients/about-the-liver/ ...
MPV Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/mpvbloodtest.html MPV Blood Test To use the sharing features on this page, please enable JavaScript. What is an MPV Blood Test? MPV stands for mean platelet volume. Platelets are ...
Flu (Influenza) Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/fluinfluenzatest.html Flu (Influenza) Test To use the sharing features on this page, please enable JavaScript. What is a Flu (Influenza) Test? Influenza, known as the flu , is a respiratory ...
ALT Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/altbloodtest.html ALT Blood Test To use the sharing features on this page, please enable JavaScript. What is an ALT Blood Test? ALT, which stands for alanine transaminase, is an ...
CCDs in the Mechanics Lab--A Competitive Alternative? (Part I).
ERIC Educational Resources Information Center
Pinto, Fabrizio
1995-01-01
Reports on the implementation of a relatively low-cost, versatile, and intuitive system to teach basic mechanics based on the use of a Charge-Coupled Device (CCD) camera and inexpensive image-processing and analysis software. Discusses strengths and limitations of CCD imaging technologies. (JRH)
Teaming introductory biology and research labs in support of undergraduate education.
Heitz, Jean G; Giffen, Cynthia J
2010-09-01
Numerous studies have indicated the need to improve the general level of science literacy among students and to increase the number of students electing science as a career. One mechanism for doing this is to involve undergraduates in research. This article reports how our Introductory Biology 152 course has worked synergistically with mentors in research labs on the University of Wisconsin-Madison campus to increase undergraduate retention in research and at the same time improve their higher order inquiry and communication skills.
Hardware and Software Integration to Support Real-Time Space Link Emulation
NASA Technical Reports Server (NTRS)
Murawski, Robert; Bhasin, Kul; Bittner, David; Sweet, Aaron; Coulter, Rachel; Schwab, Devin
2012-01-01
Prior to operational use, communications hardware and software must be thoroughly tested and verified. In space-link communications, field testing equipment can be prohibitively expensive and cannot test to non-ideal situations. In this paper, we show how software and hardware emulation tools can be used to accurately model the characteristics of a satellite communication channel in a lab environment. We describe some of the challenges associated with developing an emulation lab and present results to demonstrate the channel modeling. We then show how network emulation software can be used to extend a hardware emulation model without requiring additional network and channel simulation hardware.
Hardware and Software Integration to Support Real-Time Space-Link Emulation
NASA Technical Reports Server (NTRS)
Murawski, Robert; Bhasin, Kul; Bittner, David
2012-01-01
Prior to operational use, communications hardware and software must be thoroughly tested and verified. In space-link communications, field testing equipment can be prohibitively expensive and cannot test to non-ideal situations. In this paper, we show how software and hardware emulation tools can be used to accurately model the characteristics of a satellite communication channel in a lab environment. We describe some of the challenges associated with developing an emulation lab and present results to demonstrate the channel modeling. We then show how network emulation software can be used to extend a hardware emulation model without requiring additional network and channel simulation hardware.
Chloride influence on the formation of lanthanum hexaboride: An in-situ diffraction study
Mattox, Tracy M.; Groome, Chloe; Doran, Andrew; ...
2018-01-31
LaB 6 has been a material of interest for decades due to its thermionic emission, plasmonic properties, and low work function, and researchers continue to discover new properties even now. In order to meet growing interest in customizing these properties, it is important to gain better control over the system and a better understanding of the fundamental mechanism of LaB 6 crystal growth and formation. Traditional synthetic methods require very high temperatures, at which point crystallization happens too quickly to be readily studied. Our discovery that LaB 6 may be made using lower temperatures has made it possible to slowmore » down crystal formation enough for lattice growth to be observed. Here, we report an in situ diffraction study of the reaction between LaCl 3 and NaBH 4 . In observing the evolution of the (1 1 1), (1 1 0), and (2 0 0) lattice planes of LaB 6, we have discovered that the Cl of LaCl3 has a strong influence on crystal formation, and that excess Cl, temperature and heating rate may all be used as tools to control the LaB 6 final product.« less
Chloride influence on the formation of lanthanum hexaboride: An in-situ diffraction study
NASA Astrophysics Data System (ADS)
Mattox, Tracy M.; Groome, Chloe; Doran, Andrew; Beavers, Christine M.; Urban, Jeffrey J.
2018-03-01
LaB6 has been a material of interest for decades due to its thermionic emission, plasmonic properties, and low work function, and researchers continue to discover new properties even now. In order to meet growing interest in customizing these properties, it is important to gain better control over the system and a better understanding of the fundamental mechanism of LaB6 crystal growth and formation. Traditional synthetic methods require very high temperatures, at which point crystallization happens too quickly to be readily studied. Our discovery that LaB6 may be made using lower temperatures has made it possible to slow down crystal formation enough for lattice growth to be observed. We report here an in situ diffraction study of the reaction between LaCl3 and NaBH4. In observing the evolution of the (1 1 1), (1 1 0), and (2 0 0) lattice planes of LaB6, we have discovered that the Cl of LaCl3 has a strong influence on crystal formation, and that excess Cl, temperature and heating rate may all be used as tools to control the LaB6 final product.
Chloride influence on the formation of lanthanum hexaboride: An in-situ diffraction study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mattox, Tracy M.; Groome, Chloe; Doran, Andrew
LaB 6 has been a material of interest for decades due to its thermionic emission, plasmonic properties, and low work function, and researchers continue to discover new properties even now. In order to meet growing interest in customizing these properties, it is important to gain better control over the system and a better understanding of the fundamental mechanism of LaB 6 crystal growth and formation. Traditional synthetic methods require very high temperatures, at which point crystallization happens too quickly to be readily studied. Our discovery that LaB 6 may be made using lower temperatures has made it possible to slowmore » down crystal formation enough for lattice growth to be observed. Here, we report an in situ diffraction study of the reaction between LaCl 3 and NaBH 4 . In observing the evolution of the (1 1 1), (1 1 0), and (2 0 0) lattice planes of LaB 6, we have discovered that the Cl of LaCl3 has a strong influence on crystal formation, and that excess Cl, temperature and heating rate may all be used as tools to control the LaB 6 final product.« less
... transport the sample from home to the lab. Examples of some common laboratory tests that require advance preparation include: Glucose tolerance, fasting, and two-hour post-prandial blood glucose tests : fasting or eating meals ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Iain; Regnier, Cindy
Science at the Theater: Berkeley Lab scientists reveal the latest research on how to reduce your carbon footprint at home, work, and when you shop. Learn how even small choices can have a big impact. Iain Walker's research focuses on optimizing the energy use and comfort of buildings. He's a staff scientist in the Energy Performance of Buildings Group, which is part of Berkeley Lab's Environmen...tal Energy Technologies Division. He's also executive editor of Home Energy Magazine. Cindy Regnier is a Project Manager in the Environmental Energy Technologies Division at Berkeley Lab. She has over 13 years of mechanical engineeringmore » design experience, with a focus on low-energy buildings. Her projects have included several LEED Platinum buildings and the design of a 200,000 sf carbon neutral, net-zero energy science museum in San Francisco. Eric Masanet is Acting Deputy Leader of the International Energy Studies Group at Berkeley Lab. His research focuses on life-cycle assessments and energy efficiency analysis. He holds a joint research appointment in the Institute of Transportation Studies at UC Berkeley.« less
Fully On-line Introductory Physics with a Lab
NASA Astrophysics Data System (ADS)
Schatz, Michael
We describe the development and implementation of a college-level introductory physics (mechanics) course and laboratory that is suited for both on-campus and on-line environments. The course emphasizes a ``Your World is Your Lab'' approach whereby students first examine and capture on video (using cellphones) motion in their immediate surroundings, and then use free, open-source software both to extract data from the video and to apply physics principles to build models that describe, predict, and visualize the observations. Each student reports findings by creating a video lab report and posting it online; these video lab reports are then distributed to the rest of the class for peer review. In this talk, we will discuss the student and instructor experiences in courses offered to three distinct audiences in different venues: (1) a Massively Open On-line Course (MOOC) for off-campus participants, (2) a flipped/blended course for on-campus students, and, most recently, (3) a fully-online course for off-campus students.
ERIC Educational Resources Information Center
Florine, Sara; Hammond, Paul; Pomart, Katrina; Balschweid, Mark
2002-01-01
Describes some inquiry-based labs in which students identify starch in popped popcorn, then determine whether starch is present in the kernels prior to them being cooked. Students distinguish monocot and dicot stems as well as determining whether boiling kills tissues in seeds that have been soaked in water. (DDR)
Williams works with LOCAD-PTS Experiment Hardware in the US Lab during Expedition 15
2007-05-05
ISS015-E-06773 (5 May 2007) --- Astronaut Sunita L. Williams, Expedition 15 flight engineer, sets up a video camera inside a flame resistant covering to film a chip during Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) Swab Operations in the Destiny laboratory of the International Space Station.
Williams works with LOCAD-PTS in Destiny lab
2007-04-01
ISS014-E-18822 (31 March 2007) --- Astronaut Sunita L. Williams, Expedition 14 flight engineer, works with the Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) experiment in the Destiny laboratory of the International Space Station. LOCAD-PTS is a handheld device for rapid detection of biological and chemical substances onboard the station.
Williams works with LOCAD-PTS in Destiny lab
2007-04-01
ISS014-E-18818 (31 March 2007) --- Astronaut Sunita L. Williams, Expedition 14 flight engineer, works with the Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) experiment in the Destiny laboratory of the International Space Station. LOCAD-PTS is a handheld device for rapid detection of biological and chemical substances onboard the station.
ISS Expedition 18 Lab-On-a-Chip Applications Development (LOCAD) OPS
2009-01-10
ISS018-E-018995 (10 Jan. 2009) --- Astronaut Sandra Magnus, Expedition 18 flight engineer, works with the Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) experiment in the Destiny laboratory of the International Space Station. LOCAD-PTS is a handheld device for rapid detection of biological and chemical substances onboard the station.
Williams works with LOCAD-PTS in Destiny lab
2007-04-01
ISS014-E-18811 (31 March 2007) --- Astronaut Sunita L. Williams, Expedition 14 flight engineer, works with the Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) experiment in the Destiny laboratory of the International Space Station. LOCAD-PTS is a handheld device for rapid detection of biological and chemical substances onboard the station.
40 CFR 63.786 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... level of sample dilution must be factored in. (2) Repeatability. First, at the 0.1-5 percent analyte... percent analyte range the results would be suspect if duplicates vary by more than 5 percent relative and...) Reproducibility. First, at the 0.1-5 percent analyte range the results would be suspect if lab to lab variation...
40 CFR 63.786 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... level of sample dilution must be factored in. (2) Repeatability. First, at the 0.1-5 percent analyte... percent analyte range the results would be suspect if duplicates vary by more than 5 percent relative and...) Reproducibility. First, at the 0.1-5 percent analyte range the results would be suspect if lab to lab variation...
Stepaniak, Pieter S; Soliman Hamad, Mohamed A; Dekker, Lukas R C; Koolen, Jacques J
2014-01-01
In this study, we sought to analyze the stochastic behavior of Catherization Laboratories (Cath Labs) procedures in our institution. Statistical models may help to improve estimated case durations to support management in the cost-effective use of expensive surgical resources. We retrospectively analyzed all the procedures performed in the Cath Labs in 2012. The duration of procedures is strictly positive (larger than zero) and has mostly a large minimum duration. Because of the strictly positive character of the Cath Lab procedures, a fit of a lognormal model may be desirable. Having a minimum duration requires an estimate of the threshold (shift) parameter of the lognormal model. Therefore, the 3-parameter lognormal model is interesting. To avoid heterogeneous groups of observations, we tested every group-cardiologist-procedure combination for the normal, 2- and 3-parameter lognormal distribution. The total number of elective and emergency procedures performed was 6,393 (8,186 h). The final analysis included 6,135 procedures (7,779 h). Electrophysiology (intervention) procedures fit the 3-parameter lognormal model 86.1% (80.1%). Using Friedman test statistics, we conclude that the 3-parameter lognormal model is superior to the 2-parameter lognormal model. Furthermore, the 2-parameter lognormal is superior to the normal model. Cath Lab procedures are well-modelled by lognormal models. This information helps to improve and to refine Cath Lab schedules and hence their efficient use.
Dewan, Sailendra; Tamang, Jyoti Prakash
2007-10-01
Ethnic people of the Himalayan regions of India, Nepal, Bhutan and China consume a variety of indigenous fermented milk products made from cows milk as well as yaks milk. These lesser-known ethnic fermented foods are dahi, mohi, chhurpi, somar, philu and shyow. The population of lactic acid bacteria (LAB) ranged from 10(7) to 10(8) cfu/g in these Himalayan milk products. A total of 128 isolates of LAB were isolated from 58 samples of ethnic fermented milk products collected from different places of India, Nepal and Bhutan. Based on phenotypic characterization including API sugar test, the dominant lactic acid bacteria were identified as Lactobacillus bifermentans, Lactobacillus paracasei subsp. pseudoplantarum, Lactobacillus kefir, Lactobacillus hilgardii, Lactobacillus alimentarius, Lactobacillus paracasei subsp. paracasei, Lactobacillus plantarum, Lactococcus lactis subsp. lactis, Lactococcus lactis subsp. cremoris and Enterococcus faecium. LAB produced a wide spectrum of enzymes and showed high galactosidase, leucine-arylamidase and phosphatase activities. They showed antagonistic properties against selected Gram-negative bacteria. None of the strains produced bacteriocin and biogenic amines under the test conditions used. Most strains of LAB coagulated skim milk with a moderate drop in pH. Some strains of LAB showed a high degree of hydrophobicity, suggesting these strains may have useful adhesive potential. This paper is the first report on functional lactic acid bacterial composition in some lesser-known ethnic fermented milk products of the Himalayas.
Butler, Éile; Oien, Rut F; Lindholm, Christina; Olofsson, Tobias C; Nilson, Bo; Vásquez, Alejandra
2016-10-01
Treatment and management of chronic wounds is a large burden on the health sector and causes substantial suffering for the patients. We believe that 13 lactic acid bacteria (LAB) symbionts isolated from the honey crop of the honeybee are important players in the antimicrobial action of honey, by producing antimicrobial substances and can be used in combination with heather honey as an effective treatment in wound management. A total of 22 patients with chronic ulcers were included; culture-dependent and molecular-based (MALDI-MS and 16S rRNA gene sequencing) techniques were used to identify bacteria from chronic wounds. These clinical isolates were used for in vitro antimicrobial testing with standardised viable LAB and sterilised heather honey mixture. Twenty of the patients' wounds were polymicrobial and 42 different species were isolated. Patient isolates that were tested in vitro were inhibited by the LAB and honey combination with inhibitory zones comparable with different antibiotics. LAB and heather honey in combination presents a new topical option in chronic wound management because of the healing properties of honey, antimicrobial metabolite production from the LAB and their bactericidal effect on common chronic wound pathogens. This new treatment may be a stepping stone towards an alternative solution to antibiotics. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Chalil Madathil, Kapil; Greenstein, Joel S
2017-11-01
Collaborative virtual reality-based systems have integrated high fidelity voice-based communication, immersive audio and screen-sharing tools into virtual environments. Such three-dimensional collaborative virtual environments can mirror the collaboration among usability test participants and facilitators when they are physically collocated, potentially enabling moderated usability tests to be conducted effectively when the facilitator and participant are located in different places. We developed a virtual collaborative three-dimensional remote moderated usability testing laboratory and employed it in a controlled study to evaluate the effectiveness of moderated usability testing in a collaborative virtual reality-based environment with two other moderated usability testing methods: the traditional lab approach and Cisco WebEx, a web-based conferencing and screen sharing approach. Using a mixed methods experimental design, 36 test participants and 12 test facilitators were asked to complete representative tasks on a simulated online shopping website. The dependent variables included the time taken to complete the tasks; the usability defects identified and their severity; and the subjective ratings on the workload index, presence and satisfaction questionnaires. Remote moderated usability testing methodology using a collaborative virtual reality system performed similarly in terms of the total number of defects identified, the number of high severity defects identified and the time taken to complete the tasks with the other two methodologies. The overall workload experienced by the test participants and facilitators was the least with the traditional lab condition. No significant differences were identified for the workload experienced with the virtual reality and the WebEx conditions. However, test participants experienced greater involvement and a more immersive experience in the virtual environment than in the WebEx condition. The ratings for the virtual environment condition were not significantly different from those for the traditional lab condition. The results of this study suggest that participants were productive and enjoyed the virtual lab condition, indicating the potential of a virtual world based approach as an alternative to conventional approaches for synchronous usability testing. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hardware Design and Testing of SUPERball, A Modular Tensegrity Robot
NASA Technical Reports Server (NTRS)
Sabelhaus, Andrew P.; Bruce, Jonathan; Caluwaerts, Ken; Chen, Yangxin; Lu, Dizhou; Liu, Yuejia; Agogino, Adrian K.; SunSpiral, Vytas; Agogino, Alice M.
2014-01-01
We are developing a system of modular, autonomous "tensegrity end-caps" to enable the rapid exploration of untethered tensegrity robot morphologies and functions. By adopting a self-contained modular approach, different end-caps with various capabilities (such as peak torques, or motor speeds), can be easily combined into new tensegrity robots composed of rods, cables, and actuators of different scale (such as in length, mass, peak loads, etc). As a first step in developing this concept, we are in the process of designing and testing the end-caps for SUPERball (Spherical Underactuated Planetary Exploration Robot), a project at the Dynamic Tensegrity Robotics Lab (DTRL) within NASA Ames's Intelligent Robotics Group. This work discusses the evolving design concepts and test results that have gone into the structural, mechanical, and sensing aspects of SUPERball. This representative tensegrity end-cap design supports robust and repeatable untethered mobility tests of the SUPERball, while providing high force, high displacement actuation, with a low-friction, compliant cabling system.
Ignatova, Tseteslava; Iliev, Ilia; Kirilov, Nikolai; Vassileva, Tonka; Dalgalarrondo, Michèle; Haertlé, Thomas; Chobert, Jean-Marc; Ivanova, Iskra
2009-10-28
Eighteen lactic acid bacteria (LAB) strains isolated from dairy products, all identified as Lactobacillus delbrueckii subsp. bulgaricus, were tested for their ability to grow on three different oligosaccharides: fructo-oligosaccharides (FOS), gluco-oligosaccharides (GOS) and galacto-oligosaccharides (GalOS). The growth of LAB on different oligosaccharides was very different. Study of the antimicrobial activities of these LAB indicated that the system of uptake of unusual sugars influenced in a specific way the production of antimicrobial substances (bacteriocins) specific against gram-negative bacteria. The added oligosaccharides induced LAB to form end-products of a typical mixed acid fermentation. The utilization of different types of oligosaccharides may help to explain the ability of Lactobacillus strains to compete with other bacteria in the ecosystem of the human gastro-intestinal tract.
2012-05-14
CAPE CANAVERAL, Fla. – Inside the Operations and Checkout Building, Rudy Werlink gives students a first-hand look at the workings of the sound testing area of cryogenics lab. The 26 honor students in chemistry and biology and their teachers got a chance to visit a number of high-tech labs at Kennedy Space Center as part of an effort to encourage students in the areas of science, technology, engineering and math. The tenth and eleventh grade students from Terry Parker High School in Jacksonville, Fla., visited a number of vastly different labs during their one-day tour. The group's visit to Kennedy was hosted by the Education Office as part of a nationwide effort by the National Lab Network to help introduce the nation's students to science careers. Photo credit: NASA/Jim Grossmann
2012-05-14
CAPE CANAVERAL, Fla. – Inside the Operations and Checkout Building, Rudy Werlink gives students a first-hand look at the workings of the sound testing area of cryogenics lab. The 26 honor students in chemistry and biology and their teachers got a chance to visit a number of high-tech labs at Kennedy Space Center as part of an effort to encourage students in the areas of science, technology, engineering and math. The tenth and eleventh grade students from Terry Parker High School in Jacksonville, Fla., visited a number of vastly different labs during their one-day tour. The group's visit to Kennedy was hosted by the Education Office as part of a nationwide effort by the National Lab Network to help introduce the nation's students to science careers. Photo credit: NASA/Jim Grossmann
... common measurements for results of these tests. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your health ...
Khan, Hafiz Azhar Ali; Akram, Waseem; Iqbal, Javaid; Naeem-Ullah, Unsar
2015-01-01
The house fly, Musca domestica L., is an important ectoparasite with the ability to develop resistance to insecticides used for their control. Thiamethoxam, a neonicotinoid, is a relatively new insecticide and effectively used against house flies with a few reports of resistance around the globe. To understand the status of resistance to thiamethoxam, eight adult house fly strains were evaluated under laboratory conditions. In addition, to assess the risks of resistance development, cross-resistance potential and possible biochemical mechanisms, a field strain of house flies was selected with thiamethoxam in the laboratory. The results revealed that the field strains showed varying level of resistance to thiamethoxam with resistance ratios (RR) at LC50 ranged from 7.66-20.13 folds. Continuous selection of the field strain (Thia-SEL) for five generations increased the RR from initial 7.66 fold to 33.59 fold. However, resistance declined significantly when the Thia-SEL strain reared for the next five generations without exposure to thiamethoxam. Compared to the laboratory susceptible reference strain (Lab-susceptible), the Thia-SEL strain showed cross-resistance to imidacloprid. Synergism tests revealed that S,S,S-tributylphosphorotrithioate (DEF) and piperonyl butoxide (PBO) produced synergism of thiamethoxam effects in the Thia-SEL strain (2.94 and 5.00 fold, respectively). In addition, biochemical analyses revealed that the activities of carboxylesterase (CarE) and mixed function oxidase (MFO) in the Thia-SEL strain were significantly higher than the Lab-susceptible strain. It seems that metabolic detoxification by CarE and MFO was a major mechanism for thiamethoxam resistance in the Thia-SEL strain of house flies. The results could be helpful in the future to develop an improved control strategy against house flies.