Science.gov

Sample records for membrane contactor accounting

  1. Superhydrophobic Membrane Contactor for Acid Gas Removal

    NASA Astrophysics Data System (ADS)

    Faiqotul Himma, Nurul; Gede Wenten, I.

    2017-07-01

    Gas-liquid membrane contactor has gained a great attention as an alternative to conventional absorption columns in acid gas removal from natural gas or post-combustion. The membrane contactor offers high mass transfer area and excellent operational flexibility. However, hydrophobic microporous membranes commonly used are still susceptible to wetting by liquid absorbents, leading to the deterioration of absorption performance in long-term operation. Therefore, many studies were recently directed to improve the membrane wetting resistant by endowing superhydrophobicity. This article then presents a review on superhydrophobic membrane development and its application for acid gas removal using membrane contactor. An overview of gas-liquid membrane contactor is firstly presented, followed by the preparation of superhydrophobic membranes. The performances of superhydrophobic membranes in acid gas absorption are then discussed, and the recommendation for future research is finally outlined. This review may provide an insight into the further development of superhydrophobic membrane contactor.

  2. Mathematical modeling of liquid/liquid hollow fiber membrane contactor accounting for interfacial transport phenomena: Extraction of lanthanides as a surrogate for actinides

    SciTech Connect

    Rogers, J.D.

    1994-08-04

    This report is divided into two parts. The second part is divided into the following sections: experimental protocol; modeling the hollow fiber extractor using film theory; Graetz model of the hollow fiber membrane process; fundamental diffusive-kinetic model; and diffusive liquid membrane device-a rigorous model. The first part is divided into: membrane and membrane process-a concept; metal extraction; kinetics of metal extraction; modeling the membrane contactor; and interfacial phenomenon-boundary conditions-applied to membrane transport.

  3. Low cost membrane contactors based on hollow fibres

    NASA Astrophysics Data System (ADS)

    Dohnal, Mirko; Vesely, Tomas; Raudensky, Miroslav

    2012-04-01

    Membrane contactors are used to solve different chemical engineering tasks (e.g. water saturation with gases). Such elements are traditionally used for bubble less oxidation of blood. However, their industrial applications are rather limited by their high investment costs. This is probably the main reason why membrane contactors are not used so widely, e.g. classical absorbers, etc. If potted bundles of hollow fibres are available, then it is a relatively simple task to design an ad hoc membrane contactor. However, it must be emphasised that to achieve the highest mass transfer efficiency requires a rather time-consuming tuning of each ad hoc designed contactor. To check the differences by water evaporation were aligned two modes, the water inside the hollow fibre membrane and fan air outside, next with the water outsides and flowing pressure air inside the membrane.

  4. Membrane contactors for CO2 capture processes - critical review

    NASA Astrophysics Data System (ADS)

    Nogalska, Adrianna; Trojanowska, Anna; Garcia-Valls, Ricard

    2017-07-01

    The use of membrane contactor in industrial processes is wide, and lately it started to be used in CO2 capture process mainly for gas purification or to reduce the emission. Use of the membrane contactor provides high contact surface area so the size of the absorber unit significantly decreases, which is an important factor for commercialization. The research has been caried out regarding the use of novel materials for the membrane production and absorbent solution improvements. The present review reveals the progress in membrane contactor systems for CO2 capture processes concerning solution for ceramic membrane wetting, comparison study of different polymers used for fabrication and methods of enzyme immobilization for biocomposite membrane. Also information about variety of absorbent solutions is described.

  5. Carbon Dioxide Absorption in a Membrane Contactor with Color Change

    ERIC Educational Resources Information Center

    Pantaleao, Ines; Portugal, Ana F.; Mendes, Adelio; Gabriel, Joaquim

    2010-01-01

    A pedagogical experiment is described to examine the physical absorption of gases, in this case carbon dioxide, in a hollow fiber membrane contactor (HFMC) where the absorption concentration profile can be followed by a color change. The HFMC is used to teach important concepts and can be used in interesting applications for students, such as…

  6. Carbon Dioxide Absorption in a Membrane Contactor with Color Change

    ERIC Educational Resources Information Center

    Pantaleao, Ines; Portugal, Ana F.; Mendes, Adelio; Gabriel, Joaquim

    2010-01-01

    A pedagogical experiment is described to examine the physical absorption of gases, in this case carbon dioxide, in a hollow fiber membrane contactor (HFMC) where the absorption concentration profile can be followed by a color change. The HFMC is used to teach important concepts and can be used in interesting applications for students, such as…

  7. Membrane contactor assisted extraction/reaction process employing ionic liquids

    DOEpatents

    Lin, Yupo J [Naperville, IL; Snyder, Seth W [Lincolnwood, IL

    2012-02-07

    The present invention relates to a functionalized membrane contactor extraction/reaction system and method for extracting target species from multi-phase solutions utilizing ionic liquids. One preferred embodiment of the invented method and system relates to an extraction/reaction system wherein the ionic liquid extraction solutions act as both extraction solutions and reaction mediums, and allow simultaneous separation/reactions not possible with prior art technology.

  8. Application of PTFE membrane for ammonia removal in a membrane contactor.

    PubMed

    Ahn, Y T; Hwang, Y H; Shin, H S

    2011-01-01

    The feasibility of a membrane contactor system for ammonia removal was studied. The mass transfer coefficient was used to quantitatively compare the effect of various operation conditions on ammonia removal efficiency. Effective removal of ammonia was possible with a Polytetrafluoroethylene (PTFE) membrane contactor system at all tested conditions. Among the various operation parameters, contact time and solution pH showed significant effect on the ammonia removal mechanism. The overall ammonia removal rate was not affected by influent suspended solution concentration unlike other pressure driven membrane filtration processes. Also the osmotic distillation phenomena which deteriorate the mass transfer efficiency can be minimized by preheating of influent wastewater. A membrane contactor system can be a possible alternative to treat high strength nitrogen wastewater by optimizing operation conditions such as stripping solution flow rate, influent wastewater temperature, and influent pH.

  9. Hollow fiber gas-liquid membrane contactors for acid gas capture: a review.

    PubMed

    Mansourizadeh, A; Ismail, A F

    2009-11-15

    Membrane contactors using microporous membranes for acid gas removal have been extensively reviewed and discussed. The microporous membrane acts as a fixed interface between the gas and the liquid phase without dispersing one phase into another that offers a flexible modular and energy efficient device. The gas absorption process can offer a high selectivity and a high driving force for transport even at low concentrations. Using hollow fiber gas-liquid membrane contactors is a promising alternative to conventional gas absorption systems for acid gas capture from gas streams. Important aspects of membrane contactor as an efficient energy devise for acid gas removal including liquid absorbents, membrane characteristics, combination of membrane and absorbent, mass transfer, membrane modules, model development, advantages and disadvantages were critically discussed. In addition, current status and future potential in research and development of gas-liquid membrane contactors for acid gas removal were also briefly discussed.

  10. Ammonia recovery from landfill leachate using hydrophobic membrane contactors.

    PubMed

    Amaral, Míriam C S; Magalhães, Nátalie C; Moravia, Wagner G; Ferreira, Carolina D

    2016-11-01

    This article aims to evaluate membrane contactors capability to remove and recover ammonia from landfill leachate (LFL). A hydrophobic hollow fiber membrane module was used to achieve such purpose. A sulfuric acid diluted solution was used as extraction solution to speed up ammonia content removal. Several factors that have influence on ammonia removal and recovery capability such as ammonia solution pH, concentration of sulfuric acid solutions and flow rate of liquid phases have been examined. Microfiltration was the method used as pretreatment. The results have shown that membrane contactor operated with LFL (pH 10), 0.1 M acid solution and liquid flow rate up to 0.5 L min(-1) achieved 99.9% of ammonia removal, which corresponds to 79.1% of ammonia recovery from the extraction solution, and it is capable to produce highly purified ammonium sulfate solutions (41.2%, wt wt(-1)) to be used as fertilizer. The concentration of total ammonia nitrogen (TAN) in the residual LFL complies with Brazilian law requirements of 20.0 mg L(-1) of TAN, regarding the disposal of effluents.

  11. Pre-Combustion Carbon Capture by a Nanoporous, Superhydrophobic Membrane Contactor Process

    SciTech Connect

    Meyer, Howard; Zhou, S James; Ding, Yong; Bikson, Ben

    2012-03-31

    This report summarizes progress made during Phase I and Phase II of the project: "Pre-Combustion Carbon Capture by a Nanoporous, Superhydrophobic Membrane Contactor Process," under contract DE-FE-0000646. The objective of this project is to develop a practical and cost effective technology for CO{sub 2} separation and capture for pre-combustion coal-based gasification plants using a membrane contactor/solvent absorption process. The goals of this technology development project are to separate and capture at least 90% of the CO{sub 2} from Integrated Gasification Combined Cycle (IGCC) power plants with less than 10% increase in the cost of energy services. Unlike conventional gas separation membranes, the membrane contactor is a novel gas separation process based on the gas/liquid membrane concept. The membrane contactor is an advanced mass transfer device that operates with liquid on one side of the membrane and gas on the other. The membrane contactor can operate with pressures that are almost the same on both sides of the membrane, whereas the gas separation membranes use the differential pressure across the membrane as driving force for separation. The driving force for separation for the membrane contactor process is the chemical potential difference of CO{sub 2} in the gas phase and in the absorption liquid. This process is thus easily tailored to suit the needs for pre-combustion separation and capture of CO{sub 2}. Gas Technology Institute (GTI) and PoroGen Corporation (PGC) have developed a novel hollow fiber membrane technology that is based on chemically and thermally resistant commercial engineered polymer poly(ether ether ketone) or PEEK. The PEEK membrane material used in the membrane contactor during this technology development program is a high temperature engineered plastic that is virtually non-destructible under the operating conditions encountered in typical gas absorption applications. It can withstand contact with most of the common treating

  12. Emulsion-liquid-membrane extraction of copper using a hollow-fiber contactor

    SciTech Connect

    Hu, S.Y.B.; Wiencek, J.M.

    1998-03-01

    A novel extraction technique using an emulsion liquid membrane within a hollow-fiber contactor was developed and utilized to extract copper using LIX 84 extractant. Emulsion liquid membranes are capable of extracting metals from dilute waste streams to levels much below those possible by equilibrium-limited solvent extraction. Utilizing an emulsion liquid membrane within a hollow-fiber contactor retains the advantages of emulsion-liquid-membrane extraction, namely, simultaneous extraction and stripping, while eliminating problems encountered in dispersive contacting methods, such as swelling and leakage of the liquid membrane. Mathematical models for extraction in hollow-fiber contactors were developed. The models satisfactorily predict the outcome of both simple solvent extraction and emulsion-liquid-membrane extraction of copper by LIX 84 in a hollow-fiber contactor over a wide range of conditions. Emulsion-liquid-membrane extraction performs exceptionally well when the extraction is close to equilibrium limit. It is also capable of extracting a solute f/rom very dilute solutions. Stability of the liquid membrane is not crucial when used in hollow-fiber contactors; the surfactant in liquid membrane can be reduced or even eliminated without severely impairing the performance.

  13. Stripping of acetone from water with microfabricated and membrane gas-liquid contactors.

    PubMed

    Constantinou, Achilleas; Ghiotto, Francesco; Lam, Koon Fung; Gavriilidis, Asterios

    2014-01-07

    Stripping of acetone from water utilizing nitrogen as a sweeping gas in co-current flow was conducted in a microfabricated glass/silicon gas-liquid contactor. The chip consisted of a microchannel divided into a gas and a liquid chamber by 10 μm diameter micropillars located next to one of the channel walls. The channel length was 35 mm, the channel width was 220 μm and the microchannel depth 100 μm. The micropillars were wetted by the water/acetone solution and formed a 15 μm liquid film between them and the nearest channel wall, leaving a 195 μm gap for gas flow. In addition, acetone stripping was performed in a microchannel membrane contactor, utilizing a hydrophobic PTFE membrane placed between two microstructured acrylic plates. Microchannels for gas and liquid flows were machined in the plates and had a depth of 850 μm and 200 μm respectively. In both contactors the gas/liquid interface was stabilized: in the glass/silicon contactor by the hydrophilic micropillars, while in the PTFE/acrylic one by the hydrophobic membrane. For both contactors separation efficiency was found to increase by increasing the gas/liquid flow rate ratio, but was not affected when increasing the inlet acetone concentration. Separation was more efficient in the microfabricated contactor due to the very thin liquid layer employed.

  14. Membrane contactor assisted water extraction system for separating hydrogen peroxide from a working solution, and method thereof

    DOEpatents

    Snyder, Seth W.; Lin, Yupo J.; Hestekin' Jamie A.; Henry, Michael P.; Pujado, Peter; Oroskar, Anil; Kulprathipanja, Santi; Randhava, Sarabjit

    2010-09-21

    The present invention relates to a membrane contactor assisted extraction system and method for extracting a single phase species from multi-phase working solutions. More specifically one preferred embodiment of the invention relates to a method and system for membrane contactor assisted water (MCAWE) extraction of hydrogen peroxide (H.sub.2O.sub.2) from a working solution.

  15. Research News: Emulsion Liquid Membrane Extraction in a Hollow-Fiber Contactor

    NASA Technical Reports Server (NTRS)

    Wiencek, John M.; Hu, Shih-Yao

    2000-01-01

    This article describes how ELMs (emulsion liquid membranes) can be used for extraction. The article addresses the disadvantages of ELM extraction in a stirred contactor, and the advantages of SELMs (supported emulsion liquid membranes). The introduction of the article provides background information on liquid-liquid solvent extraction and dispersion-free solvent extraction.

  16. Research News: Emulsion Liquid Membrane Extraction in a Hollow-Fiber Contactor

    NASA Technical Reports Server (NTRS)

    Wiencek, John M.; Hu, Shih-Yao

    2000-01-01

    This article describes how ELMs (emulsion liquid membranes) can be used for extraction. The article addresses the disadvantages of ELM extraction in a stirred contactor, and the advantages of SELMs (supported emulsion liquid membranes). The introduction of the article provides background information on liquid-liquid solvent extraction and dispersion-free solvent extraction.

  17. Membrane contactor/separator for an advanced ozone membrane reactor for treatment of recalcitrant organic pollutants in water

    SciTech Connect

    Chan, Wai Kit; Joueet, Justine; Heng, Samuel; Yeung, King Lun; Schrotter, Jean-Christophe

    2012-05-15

    An advanced ozone membrane reactor that synergistically combines membrane distributor for ozone gas, membrane contactor for pollutant adsorption and reaction, and membrane separator for clean water production is described. The membrane reactor represents an order of magnitude improvement over traditional semibatch reactor design and is capable of complete conversion of recalcitrant endocrine disrupting compounds (EDCs) in water at less than three minutes residence time. Coating the membrane contactor with alumina and hydrotalcite (Mg/Al=3) adsorbs and traps the organics in the reaction zone resulting in 30% increase of total organic carbon (TOC) removal. Large surface area coating that diffuses surface charges from adsorbed polar organic molecules is preferred as it reduces membrane polarization that is detrimental to separation. - Graphical abstract: Advanced ozone membrane reactor synergistically combines membrane distributor for ozone, membrane contactor for sorption and reaction and membrane separator for clean water production to achieve an order of magnitude enhancement in treatment performance compared to traditional ozone reactor. Highlights: Black-Right-Pointing-Pointer Novel reactor using membranes for ozone distributor, reaction contactor and water separator. Black-Right-Pointing-Pointer Designed to achieve an order of magnitude enhancement over traditional reactor. Black-Right-Pointing-Pointer Al{sub 2}O{sub 3} and hydrotalcite coatings capture and trap pollutants giving additional 30% TOC removal. Black-Right-Pointing-Pointer High surface area coating prevents polarization and improves membrane separation and life.

  18. Modeling multicomponent gas separation using hollow-fiber membrane contactors

    SciTech Connect

    Coker, D.T.; Freeman, B.D.; Fleming, G.K.

    1998-06-01

    A model developed for multicomponent gas separation using hollow-fiber contactors permits simulation of cocurrent, countercurrent, and crossflow contacting patterns with permeate purging (or sweep). The numerical approach proposed permits simulation to much higher stage cuts than previously published work and provides rapid and stable solutions for cases with many components, with widely varying permeability coefficients. This new approach also permits the rational and straightforward incorporation of effects such as permeate sweep, pressure-dependent permeability coefficients, and bore side pressure gradients. Simulation results are presented for separation of commercially significant multicomponent gas mixtures using polymer permeation properties similar to those of polysulfone. The effect of permeate purging on separation performance is explored for air separation. The influence of pressure ratio on hydrogen separation performance for a refinery stream is presented. Air is modeled as a four-component mixture of O{sub 2}, N{sub 2}, CO{sub 2}, and H{sub 2}O and the refinery stream contains five components: H{sub 2}, CH{sub 4}, C{sub 2}H{sub 4}, C{sub 2}H{sub 6}, and C{sub 3}H{sub 8}. In air separation, permeate purging with a small fraction of the residue stream provides a very effective method for improving module efficiency for drying but is not efficient for improving nitrogen purity or recovery. In multicomponent mixtures, maxima in the compositions of components of intermediate permeability may be observed as a function of distance along the hollow fiber. This result suggests the use of membrane staging to capture these components at their maximum concentration.

  19. Separation of boric acid in liquid waste with anion exchange membrane contactor

    SciTech Connect

    Park, J.K.; Lee, K.J.

    1995-12-31

    In order to separate boric acid in liquid waste, some possible technologies were investigated and the membrane contactor without dispersion and density differences was selected. The separation experiments on a Celgard 3401{reg_sign} hydrophilic microporous membrane contactor were first performed to obtain the basic data and to determine the properties of the contactor. The experimental conditions were as follows: boric acid concentrations up to 2.0 M, pH 7.0, temperatures of 25 and 55 C, and flow rates of 100, 300, 500, and 800 cm{sup 3}/min. Secondly, an AFN{reg_sign} anion exchange membrane contactor was tested at temperatures of 40 and 55 C and flow rate 400 cm{sup 3}/min. Boric acid solutions were prepared by the same method as that for Celgard 3401{reg_sign} but contained 5.0{times}10{sup {minus}4} M cobalt chloride (CoCl{sub 2}). To simulate membrane contractors, parameters such as the differential diffusion coefficients of boric acid and the mass transfer coefficients in the AFN membrane were measured, and regression models estimating the diffusion coefficient at several conditions were developed. The Celgard 3401{reg_sign} membrane contactor was simulated and compared with experimental data. Simulation results agreed with the experimental data well when a proper correction factor was utilized. The correction factor was independent of the solution temperature and was 8.75 at the flow rates of 300--800 cm{sup 3}/min. This correction factor was also applied to simulate the AFN{reg_sign} resulted in a good agreement with experiment at 40 C, but not 55 C. The retention on cobalt was also better at 40 c than 55 C. The simulating computer program was also applied to a life size contactor designed conceptually.

  20. Membrane contactors in the beverage industry for controlling the water gas composition.

    PubMed

    Criscuoli, Alessandra; Drioli, Enrico; Moretti, Ugo

    2003-03-01

    In the work described here, membrane contactors are used for coupling the removal of species (oxygen and hydrogen sulfide) present in the water with the water carbonation process. We include both experiments and a theoretical study devoted to the analysis of the transport phenomena that occur in the membrane contactor. The main resistance to mass transport was located at the liquid side. Correlations between Sherwood and Reynolds numbers on the shell side that are suitable for the membrane contactor used to carry out our experiments have been determined. In particular, for Re > 1.6, the expression proposed by Yang and Cussler in 1986: Sh = 0.90 Re(0.40) Sc(0.33) describes the behavior of the system; whereas, for Re between 0.03 and 0.3, a new expression is proposed: Sh = 0.435 Re(1.2)Sc(0.33). A comparison with traditional equipment is also furnished. Membrane contactors offer reduced size, CO(2) consumption, and capital costs.

  1. The use of emulsions, microemulsions, and hollow fiber contactors as liquid membranes

    SciTech Connect

    Wiencek, J.M.; Hu, S.Y.; Raghuraman, B.

    1995-12-01

    Liquid membranes as a generic concept have primarily involved the use of either porous solid film impregnated with a liquid carrier or emulsified systems employed in a stirred contactor. Although such systems can display high selectivities and reasonable flux, the stability of the liquid membrane to rupture (i.e. leakage) and unwanted water transport (i.e. swell) have limited their commercial application. Our lab has focused on developing improved emulsion liquid membranes. In particular, we have investigated the possibility of employing microemulsions as liquid membranes to separate metals (especially mercury) from contaminated water. Our most current work on the use of hollow fiber contactors as a means of minimizing swell and leakage in emulsion liquid membrane systems will also be presented.

  2. Recovery of volatile fatty acids via membrane contactor using flat membranes: experimental and theoretical analysis.

    PubMed

    Tugtas, Adile Evren

    2014-07-01

    Volatile fatty acid (VFA) separation from synthetic VFA solutions and leachate was investigated via the use of a membrane contactor. NaOH was used as a stripping solution to provide constant concentration gradient of VFAs in both sides of a membrane. Mass flux (12.23 g/m(2)h) and selectivity (1.599) observed for acetic acid were significantly higher than those reported in the literature and were observed at feed pH of 3.0, flow rate of 31.5 ± 0.9 mL/min, and stripping solution concentration of 1.0 N. This study revealed that the flow rate, stripping solution strength, and feed pH affect the mass transfer of VFAs through the PTFE membrane. Acetic and propionic acid separation performances observed in the present study provided a cost effective and environmental alternative due to elimination of the use of extractants.

  3. Numerical simulation of reactive extraction of benzoic acid from wastewater via membrane contactors.

    PubMed

    Ghadiri, Mehdi; Shirazian, Saeed

    2017-04-01

    Membrane-based non-dispersive solvent extraction is used in many chemical processes due to its significant benefits such as straightforward scale-up and low energy consumption. A mechanistic model was developed to predict recovery of benzoic acid (BA) from wastewater using membrane contactors. Model equations were derived for benzoic acid transport in the membrane module, and solved using FEM. The model findings were compared with experimental results, and an average deviation of 4% was observed between experimental and simulation results. Simulations showed that change in organic phase flowrate and initial concentration of BA does not have considerable effect on the removal efficiency of benzoic acid. In addition, increasing feed flowrate leads to the enhancement of convective mass transfer flux in the tube side of membrane contactor which decreases removal efficiency of benzoic acid.

  4. Membrane contactor/separator for an advanced ozone membrane reactor for treatment of recalcitrant organic pollutants in water

    NASA Astrophysics Data System (ADS)

    Kit Chan, Wai; Jouët, Justine; Heng, Samuel; Lun Yeung, King; Schrotter, Jean-Christophe

    2012-05-01

    An advanced ozone membrane reactor that synergistically combines membrane distributor for ozone gas, membrane contactor for pollutant adsorption and reaction, and membrane separator for clean water production is described. The membrane reactor represents an order of magnitude improvement over traditional semibatch reactor design and is capable of complete conversion of recalcitrant endocrine disrupting compounds (EDCs) in water at less than three minutes residence time. Coating the membrane contactor with alumina and hydrotalcite (Mg/Al=3) adsorbs and traps the organics in the reaction zone resulting in 30% increase of total organic carbon (TOC) removal. Large surface area coating that diffuses surface charges from adsorbed polar organic molecules is preferred as it reduces membrane polarization that is detrimental to separation.

  5. Extraction with emulsion liquid membranes in a hollow-fiber contactor

    SciTech Connect

    Raghuraman, B.; Wiencek, J. . Dept. of Chemical and Biochemical Engineering)

    1993-11-01

    Aqueous streams contaminated with heavy metal ions may be produced as effluents from industrial plants or during attempts to remediate solids loaded with heavy metals, such as contaminated soils. Metals of particular concern include copper, zinc, cadmium, nickel, mercury, lead, and chromium. An extraction system for heavy metals recovery from dilute waste streams, which can accomplish both extraction and stripping in one step, is an emulsion liquid membrane (ELM). The ELM extraction in a stirred contactor has two main disadvantages. On prolonged contact with the feed stream (greater than 10 min), the emulsion swells with water, increasing the internal-phase volume and in a stirred contactor the internal-phase contents leak into the feed stream because of membrane rupture. This work focuses on the use of microporous hollow-fiber contactors (HFC) as an alternate contacting method to direct batch/continuous dispersion of emulsion liquid membranes. This method of contact will retain the primary advantage that emulsion liquid membrane separations offer, namely, extraction and stripping in a single processing step which circumvents the limits of equilibrium inherent in conventional solvent extraction. However, because hollow-fiber membranes, by their design, allow for high surface area contacting without the high shear rates typically encountered with an agitator, this will result in improved efficiency of extraction by reducing membrane swelling and leakage.

  6. Liposome and niosome preparation using a membrane contactor for scale-up.

    PubMed

    Pham, Thi Thuy; Jaafar-Maalej, Chiraz; Charcosset, Catherine; Fessi, Hatem

    2012-06-01

    The scaling-up ability of liposome and niosome production, from laboratory scale using a syringe-pump device to a pilot scale using the membrane contactor module, was investigated. For this aim, an ethanol injection-based method was applied for liposome and niosome preparation. The syringe-pump device was used for laboratory scale batches production (30 ml for liposomes, 20 ml for niosomes) then a pilot scale (750 ml for liposomes, 1000 ml for niosomes) were obtained using the SPG membrane contactor. Resulted nanovesicles were characterized in terms of mean vesicles size, polydispersity index (PdI) and zeta potential. The drug encapsulation efficiency (E.E.%) was evaluated using two drug-models: caffeine and spironolactone, a hydrophilic and a lipophilic molecule, respectively. As results, nanovectors mean size using the syringe-pump device was comprised between 82 nm and 95 nm for liposomes and between 83 nm and 127 nm for niosomes. The optimal E.E. of caffeine within niosomes, was found around 9.7% whereas the spironolactone E.E. reached 95.6% which may be attributed to its lipophilic properties. For liposomes these values were about 9.7% and 86.4%, respectively. It can be clearly seen that the spironolactone E.E. was slightly higher within niosomes than liposomes. Optimized formulations, which offered smaller size and higher E.E., were selected for pilot scale production using the SPG membrane. It has been found that vesicles characteristics (size and E.E.%) were reproducible using the membrane contactor module. Thus, the current study demonstrated the usefulness of the membrane contactor as a device for scaling-up both liposome and niosome preparations with small mean sizes. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Emergency membrane contactor based absorption system for ammonia leaks in water treatment plants.

    PubMed

    Shao, Jiahui; Fang, Xuliang; He, Yiliang; Jin, Qiang

    2008-01-01

    Abstract Because of the suspected health risks of trihalomethanes (THMs), more and more water treatment plants have replaced traditional chlorine disinfection process with chloramines but often without the proper absorption system installed in the case of ammonia leaks in the storage room. A pilot plant membrane absorption system was developed and installed in a water treatment plant for this purpose. Experimentally determined contact angle, surface tension, and corrosion tests indicated that the sulfuric acid was the proper choice as the absorbent for leaking ammonia using polypropylene hollow fiber membrane contactor. Effects of several operating conditions on the mass transfer coefficient, ammonia absorption, and removal efficiency were examined, including the liquid concentration, liquid velocity, and feed gas concentration. Under the operation conditions investigated, the gas absorption efficiency over 99.9% was achieved. This indicated that the designed pilot plant membrane absorption system was effective to absorb the leaking ammonia in the model storage room. The removal rate of the ammonia in the model storage room was also experimentally and theoretically found to be primarily determined by the ammonia suction flow rate from the ammonia storage room to the membrane contactor. The ammonia removal rate of 99.9% was expected to be achieved within 1.3 h at the ammonia gas flow rate of 500 m3/h. The success of the pilot plant membrane absorption system developed in this study illustrated the potential of this technology for ammonia leaks in water treatment plant, also paved the way towards a larger scale application.

  8. A new process for drug loaded nanocapsules preparation using a membrane contactor.

    PubMed

    Charcosset, Catherine; Fessi, Hatem

    2005-12-01

    In this paper, we describe a new process for the preparation of drug loaded nanocapsules using a membrane contactor which may be scaled up for industrial applications. Nanocapsules are prepared according to the nanoprecipitation method. The organic phase (solvent, polymer, oil, and drug) is pressed through the pores of an ultrafiltration membrane via the filtrate side. The aqueous phase (water and surfactant) circulates inside the membrane module, and sweeps away the nanocaspules forming at the pore outlets. Two model drugs are selected for the preparation of drug loaded nanocapsules: indomethacin and vitamin E. It is shown that indomethacin loaded nanocapsules with a mean diameter of 240 nm and vitamin E loaded nanocapsules with a mean diameter of 230 nm are obtained with a 150,000 daltons ultrafiltration membrane, a transmembrane pressure of 3 bar, and a crossflow rate of 1.7 m.s(- 1). High fluxes are also obtained (around 0.6 m3/h.m2), leading to the preparation of 1.8 10(- 3) m3 drug loaded nanocapsules in 8 min. The advantage of this membrane contactor compared to other processes for drug loaded nanocapsules preparation is shown to be its scale-up ability.

  9. Analysis of ammonia separation from purge gases in microporous hollow fiber membrane contactors.

    PubMed

    Karami, M R; Keshavarz, P; Khorram, M; Mehdipour, M

    2013-09-15

    In this study, a mathematical model was developed to analyze the separation of ammonia from the purge gas of ammonia plants using microporous hollow fiber membrane contactors. A numerical procedure was proposed to solve the simultaneous linear and non linear partial differential equations in the liquid, membrane and gas phases for non-wetted or partially wetted conditions. An equation of state was applied in the model instead of Henry's law because of high solubility of ammonia in water. The experimental data of CO₂-water system in the literature was used to validate the model due to the lack of data for ammonia-water system. The model showed that the membrane contactor can separate ammonia very effectively and with recoveries higher than 99%. SEM images demonstrated that ammonia caused some micro-cracks on the surfaces of polypropylene fibers, which could be an indication of partial wetting of membrane in long term applications. However, the model results revealed that the membrane wetting did not have significant effect on the absorption of ammonia because of very high solubility of ammonia in water. It was also found that the effect of gas velocity on the absorption flux was much more than the effect of liquid velocity. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Liquid-liquid extraction of uranium(VI) in the system with a membrane contactor.

    PubMed

    Biełuszka, Paweł; Zakrzewska, Grażyna; Chajduk, Ewelina; Dudek, Jakub

    Raising role of the nuclear power industry, including governmental plans for the construction of first nuclear power plant in Poland, creates increasing demand for the uranium-based nuclear fuels. The project implemented by Institute of Nuclear Chemistry and Technology concerns the development of effective methods for uranium extraction from low-grade ores and phosphorites for production of yellow cake-U3O8. The Liqui-Cel(®) Extra-Flow 2.5 × 8 Membrane Contactor produced by CELGARD LLC (Charlotte, NC) company is the main component of the installation for liquid-liquid extraction applied for processing of post leaching liquors. In the process of membrane extraction the uranyl ions from aqueous phase are transported through the membrane into organic phase. The flow of two phases in the system was arranged in co-current mode. The very important element of the work was a selection of extracting agents appropriate for the membrane process. After preliminary experiments comprising tests of membrane resistivity and determination of extraction efficiency, di(2-ethylhexyl)phosphoric acid was found to be most favourable. An important aspect of the work was the adjustment of hydrodynamic conditions in the capillary module. To avoid the membrane wettability by organic solvent and mixing two phases equal pressure drops along the membrane module to minimize the transmembrane pressure, were assumed. Determination of pressure drop along the module was conducted using Bernoulli equation. The integrated process of extraction/re-extraction conducted in continuous mode with application of two contactors was designed.

  11. Innovative use of membrane contactor as condenser for heat recovery in carbon capture.

    PubMed

    Yan, Shuiping; Zhao, Shuaifei; Wardhaugh, Leigh; Feron, Paul H M

    2015-02-17

    The gas-liquid membrane contactor generally used as a nonselective gas absorption enhancement device is innovatively proposed as a condenser for heat recovery in liquid-absorbent-based carbon capture. The membrane condenser is used as a heat exchanger to recover the latent heat of the exiting vapor from the desorber, and it can help achieve significant energy savings when proper membranes with high heat-transfer coefficients are used. Theoretical thermodynamic analysis of mass and heat transfer in the membrane condensation system shows that heat recovery increases dramatically as inlet gas temperature rises and outlet gas temperature falls. The optimal split mass flow rate is determined by the inlet gas temperature and the overall heat-transfer coefficient in the condensation system. The required membrane area is also strongly dependent on the overall heat-transfer coefficient, particularly at higher inlet gas temperatures. Mass transfer across the membrane has an insignificant effect on heat transfer and heat recovery, suggesting that membrane wetting may not be an issue when a membrane condenser is used for heat recovery. Our analysis provides important insights into the energy recovery performance of the membrane condensation system as well as selection of operational parameters, such as split mass flow rate and membrane area, thickness, and thermal conductivity.

  12. Hybrid membrane contactor system for creating semi-breathing air

    NASA Astrophysics Data System (ADS)

    Timofeev, D. V.

    2012-02-01

    Typically, the equipment to create an artificial climate does not involve changing the composition of the respiratory air. In particular in medical institutions assumes the existence of plant of artificial climate and disinfection in operating rooms and intensive care wards. The use of a hybrid membrane-absorption systems for the generation of artificial atmospheres are improving the respiratory system, blood is enriched or depleted of various gases, resulting in increased stamina, there is a better, faster or slower metabolism, improves concentration and memory. Application of the system contributes to easy and rapid recovery after the operation. By adding a special component, with drug activity, air ionization, and adjust its composition, you can create a special, more favorable for patients with the atmosphere. These factors allow for the treatment and rehabilitation of patients and reduce mortality of heavy patients.

  13. Effect of polymer concentration on the structure and performance of PEI hollow fiber membrane contactor for CO2 stripping.

    PubMed

    Naim, R; Ismail, A F

    2013-04-15

    A series of polyetherimide (PEI) hollow fiber membranes with various polymer concentrations (13-16 wt.%) for CO2 stripping process in membrane contactor application was fabricated via wet phase inversion method. The PEI membranes were characterized in terms of liquid entry pressure, contact angle, gas permeation and morphology analysis. CO2 stripping performance was investigated via membrane contactor system in a stainless steel module with aqueous diethanolamine as liquid absorbent. The hollow fiber membranes showed decreasing patterns in gas permeation, contact angle, mean pore size and effective surface porosity with increasing polymer concentration. On the contrary, wetting pressure of PEI membranes has enhanced significantly with polymer concentration. Various polymer concentrations have different effects on the CO2 stripping flux in which membrane with 14 wt.% polymer concentration showed the highest stripping flux of 2.7 × 10(-2)mol/m(2)s. From the performance comparison with other commercial membrane, it is anticipated that the PEI membrane has a good prospect in CO2 stripping via membrane contactor. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Tube-side mass transfer for hollow fibre membrane contactors operated in the low Graetz range.

    PubMed

    Wang, C Y; Mercer, E; Kamranvand, F; Williams, L; Kolios, A; Parker, A; Tyrrel, S; Cartmell, E; McAdam, E J

    2017-02-01

    Transformation of the tube-side mass transfer coefficient derived in hollow fibre membrane contactors (HFMC) of different characteristic length scales (equivalent diameter and fibre length) has been studied when operated in the low Graetz range (Gz<10). Within the low Gz range, mass transfer is generally described by the Graetz problem (Sh=3.67) which assumes that the concentration profile comprises a constant shape over the fibre radius. In this study, it is experimentally evidenced that this assumption over predicts mass transfer within the low Graetz range. Furthermore, within the low Gz range (below 2), a proportional relationship between the experimentally determined mass transfer coefficient (Kov ) and the Graetz number has been identified. For Gz numbers below 2, the experimental Sh number approached unity, which suggests that mass transfer is strongly dependent upon diffusion. However, within this diffusion controlled region of mass transfer, tube-side fluid velocity remained important. For Gz numbers above 2, Sh could be satisfactorily described by extension to the Lévêque solution, which can be ascribed to the constrained growth of the concentration boundary layer adjacent to the fibre wall. Importantly this study demonstrates that whilst mass transfer in the low Graetz range does not explicitly conform to either the Graetz problem or classical Lévêque solution, it is possible to transform the experimentally derived overall mass transfer coefficient (Kov ) between characteristic length scales (dh and L). T h is was corroborated by comparison of the empirical relationship determined in this study (Sh=0.36Gz) with previously published studies operated in the low Gz range. This analysis provides important insight for process design when slow tube-side flows, or low Schmidt numbers (coincident with gases) constrain operation of hollow fibre membrane contactors to the low Gz range.

  15. Stability study and lyophilization of vitamin E-loaded nanocapsules prepared by membrane contactor.

    PubMed

    Khayata, N; Abdelwahed, W; Chehna, M F; Charcosset, C; Fessi, H

    2012-12-15

    In this research, we studied the accelerated stability of vitamin E-loaded nanocapsules (NCs) prepared by the nanoprecipitation method. Vitamin E-loaded NCs were optimized firstly at the laboratory scale and then scaled up using the membrane contactor technique. The optimum conditions of the membrane contactor preparation (pilot scale) produced vitamin E-loaded NCs with an average size of 253 nm, polydispersity index 0.19 and a zeta potential -16 mV. The average size, polydispersity index and zeta potential values were 185 nm, 0.12 and -15 mV, respectively for the NCs prepared at laboratory scale. No significant changes were noticed in these values after 3 and 6 months of storage at high temperature (40±2 °C) and relative humidity (75±5%) in spite of vitamin E sensitivity to light, heat and oxygen. The entrapment efficiency of NCs prepared at pilot scale was 97% at the beginning of the stability study, and became (95%, 59%) after 3 and 6 months of storage, respectively. These values at lab-scale were (98%, 96%, and 89%) at time zero and after 3 and 6 months of storage, respectively. This confirms the ability of vitamin E encapsulation to preserve its stability, which is one major goal of our work. Lyophilization of the optimized formula at lab-scale was also performed. Four types of cryoprotectants were tested (poly(vinyl pyrrolidone), sucrose, mannitol, and glucose). Freeze-dried NCs prepared with sucrose were found acceptable. The other lyophilized NCs obtained at different conditions presented large aggregates. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Microbial degradation of phenol in high-salinity solutions in suspensions and hollow fiber membrane contactors.

    PubMed

    Juang, Ruey-Shin; Wu, Cheng-Ying

    2007-01-01

    A microporous polypropylene (PP) hollow fiber membrane contactor was used as a bioreactor to degrade phenol in aqueous solutions by Pseudomonas putida BCRC 14365 at 30 degrees C. The fibers were pre-wetted by ethanol to make them more hydrophilic. The initial cell density was fixed at 0.025 gl(-1). The effects of added NaCl concentration (0-1.78 M) and pH (3-8) in substrate solution on the biodegradation were studied. The experimental results by suspended cells were discussed. It was shown that the cells in microporous hollow fibers were unable to tolerate substrate solution pH to a larger range than those in suspensions. The suspended cells grew well on 100 mg l(-1) of phenol only at NaCl concentrations below 0.44 M. However, the cells in microporous hollow fibers could completely degrade 500 mg l(-1) of phenol in solutions containing NaCl concentration up to 1.52 M, which was due to the enhanced tolerance limit to salinity effect by the membrane-attached biofilms and the sufficiently slow mass transfer of NaCl through the membrane pores.

  17. Performance of polydimethylsiloxane membrane contactor process for selective hydrogen sulfide removal from biogas.

    PubMed

    Tilahun, Ebrahim; Bayrakdar, Alper; Sahinkaya, Erkan; Çalli, Bariş

    2017-03-01

    H2S in biogas affects the co-generation performance adversely by corroding some critical components within the engine and it has to be removed in order to improve the biogas quality. This work presents the use of polydimethylsiloxane (PDMS) membrane contactor for selective removal of H2S from the biogas. Experiments were carried out to evaluate the effects of different pH of absorption liquid, biogas flowrate and temperature on the absorption performances. The results revealed that at the lowest loading rate (91mg H2S/m(2)·h) more than 98% H2S and 59% CO2 absorption efficiencies were achieved. The CH4 content in the treated gas increased from 60 to 80% with nearly 5% CH4 loss. Increasing the pH (7-10) and loading rate (91-355mg H2S/m(2)·h) enhanced the H2S absorption capacity, and the maximum H2S/CO2 and H2S/CH4 selectivity factors were 2.5 and 58, respectively. Temperature played a key role in the process and lower temperature was beneficial for intensifying H2S absorption performance. The highest H2S fluxes at pH 10 and 7 were 3.4g/m(2)·d and 1.8g/m(2)·d with overall mass transfer coefficients of 6.91×10(-6) and 4.99×10(-6)m/s, respectively. The results showed that moderately high H2S fluxes with low CH4 loss may be achieved by using a robust and cost-effective membrane based absorption process for desulfurization of biogas. A tubular PDMS membrane contactor was tested for the first time to remove H2S from biogas under slightly alkaline conditions and the suggested process could be a promising for real scale applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Operation of a breadboard liquid-sorbent/membrane-contactor system for removing carbon dioxide and water vapor from air

    NASA Technical Reports Server (NTRS)

    Mccray, Scott B.; Ray, Rod; Newbold, David D.; Millard, Douglas L.; Friesen, Dwayne T.; Foerg, Sandra

    1992-01-01

    Processes to remove and recover carbon dioxide (CO2) and water vapor from air are essential for successful long-duration space missions. This paper presents results of a developmental program focused on the use of a liquid-sorbent/membrane-contactor (LSMC) system for removal of CO2 and water vapor from air. In this system, air from the spacecraft cabin atmosphere is circulated through one side of a hollow-fiber membrane contactor. On the other side of the membrane contactor is flowed a liquid sorbent, which absorbs the CO2 and water vapor from the feed air. The liquid sorbent is then heated to desorb the CO2 and water vapor. The CO2 is subsequently removed from the system as a concentrated gas stream, whereas the water vapor is condensed, producing a water stream. A breadboard system based on this technology was designed and constructed. Tests showed that the LSMC breadboard system can produce a CO2 stream and a liquid-water stream. Details are presented on the operation of the system, as well as the effects on performance of variations in feed conditions.

  19. Operation of a breadboard liquid-sorbent/membrane-contactor system for removing carbon dioxide and water vapor from air

    NASA Technical Reports Server (NTRS)

    Mccray, Scott B.; Ray, Rod; Newbold, David D.; Millard, Douglas L.; Friesen, Dwayne T.; Foerg, Sandra

    1992-01-01

    Processes to remove and recover carbon dioxide (CO2) and water vapor from air are essential for successful long-duration space missions. This paper presents results of a developmental program focused on the use of a liquid-sorbent/membrane-contactor (LSMC) system for removal of CO2 and water vapor from air. In this system, air from the spacecraft cabin atmosphere is circulated through one side of a hollow-fiber membrane contactor. On the other side of the membrane contactor is flowed a liquid sorbent, which absorbs the CO2 and water vapor from the feed air. The liquid sorbent is then heated to desorb the CO2 and water vapor. The CO2 is subsequently removed from the system as a concentrated gas stream, whereas the water vapor is condensed, producing a water stream. A breadboard system based on this technology was designed and constructed. Tests showed that the LSMC breadboard system can produce a CO2 stream and a liquid-water stream. Details are presented on the operation of the system, as well as the effects on performance of variations in feed conditions.

  20. Recovery of methane from anaerobic process effluent using poly-di-methyl-siloxane membrane contactors.

    PubMed

    Cookney, J; Cartmell, E; Jefferson, B; McAdam, E J

    2012-01-01

    This paper demonstrates the potential for recovering dissolved methane from low temperature anaerobic processes treating domestic wastewater. In the absence of methane recovery, ca. 45% of the produced methane is released as a fugitive emission which results in a net carbon footprint of -0.47 kg CO(2e) m(-3). A poly-di-methyl-siloxane (PDMS) membrane contactor was applied to support sweep gas desorption of dissolved methane using nitrogen. The dense membrane structure controlled gaseous mass transfer thus recovery was maximised at low liquid velocities. At the lowest liquid velocity, V(L), of 0.0025 m s(-1), 72% of the dissolved methane was recovered. A vacuum was also trialled as an alternative to sweep-gas operation. At vacuum pressures below 30 mbar, reasonable methane recovery was observed at an intermediate V(L) of 0.0056 m s(-1). Results from this study demonstrate that dissolved methane recovery could increase net electrical production from low temperature anaerobic processes by ca. +0.043 kWh(e) m(-3) and reduce the net carbon footprint to +0.01 kg CO(2e) m(-3). However, further experimental work to optimise the gas-side hydrodynamics is required as well as validation of the long-term impacts of biofouling on process performance.

  1. Effect of disintegrated sludge recycling on membrane permeability in a membrane bioreactor combined with a turbulent jet flow ozone contactor.

    PubMed

    Hwang, Byung-Kook; Kim, Jae-Hyuk; Ahn, Chang Hoon; Lee, Chung-Hak; Song, Jae-Yoon; Ra, Young-Hyun

    2010-03-01

    We have combined a turbulent jet flow ozone contactor (TJC) with a membrane bioreactor (MBR) to establish a zero-discharge system in terms of excess sludge in the MBR. The TJC-MBR system was compared with the conventional MBR (Control-MBR) with respect to i) the size and zeta potential of the sludge particles, ii) the loosely bound extra-cellular polymeric substances (EPSs) and tightly bound EPS of the microbial flocs, iii) the porosity and biovolume of the bio-cake accumulated on the membrane, and iv) the membrane permeability. The TJC system generated the ozonated sludge with a negligible amount of loosely bound EPS and a positive zeta potential. As a result, when such ozonated sludge was recycled, the average size of the sludge particles (e.g., microbial flocs) increased in the TJC-MBR. Consequently the bio-cake formed in the TJC-MBR had greater porosity than that in the Control-MBR, giving rise to higher membrane permeability in the TJC-MBR.

  2. Application of hollow fiber membrane contactors for catalyst recovery in the WPO process.

    PubMed

    Ortiz, Inmaculada; Urtiaga, Ane; Abellán, M José; San Román, Fresnedo

    2003-03-01

    In this work the use of a membrane based liquid extraction process for recovery of the homogeneous catalyst employed in the wet peroxide oxidation process (WPO) is studied. In the WPO process the oxidation agent is the hydroxyl radical that is obtained by using a combination of hydrogen peroxide and a mixture of Fe(II), Cu(II), and Mn(II) in aqueous solution. The mixture of metallic cations permits the almost total degradation of the refractory organic compounds, but the use of metallic salts as catalysts induces additional pollution. To recover the homogeneous catalyst of the WPO process by means of non-dispersive solvent extraction (NDSX) two hollow fiber membrane contactors are employed, one for the extraction step and the second for the back-extraction step. From the initial assays, the extractant LIX 622N was selected for Cu(II) recovery and Cyanex 272 for Fe(II) and Mn(II) recovery. Selective separation of Fe(II) and Mn(II) can be obtained by adjusting the pH of the feed aqueous phase. The three metals are stripped using sulfuric acid to give concentrated solutions of CuSO(4), FeSO(4), and MnSO(4) that can be recycled to the formulation of the catalyst solution of the WPO process. A mathematical model has been proposed to describe the recovery of Cu. Two design parameters are required: the membrane mass transport coefficient of the extraction and stripping modules (k(m) = 3.07 x 10(-7) m/sec) and the equilibrium parameter of the extraction reaction (K(Ex) = 0.0832).

  3. A portable membrane contactor sampler for analysis of noble gases in groundwater.

    PubMed

    Matsumoto, Takuya; Han, Liang-Feng; Jaklitsch, Manfred; Aggarwal, Pradeep K

    2013-01-01

    To enable a wider use of dissolved noble gas concentrations and isotope ratios in groundwater studies, we have developed an efficient and portable sampling device using a commercially available membrane contactor. The device separates dissolved gases from a stream of water and collects them in a small copper tube (6 mm in diameter and 100 mm in length with two pinch-off clamps) for noble gas analysis by mass spectrometry. We have examined the performance of the sampler using a tank of homogeneous water prepared in the laboratory and by field testing. We find that our sampling device can extract heavier noble gases (Ar, Kr, and Xe) more efficiently than the lighter ones (He and Ne). An extraction time of about 60 min at a flow rate of 3 L/min is sufficient for all noble gases extracted in the sampler to attain equilibrium with the dissolved phase. The extracted gas sample did not indicate fractionation of helium ((3) He/(4) He) isotopes or other noble gas isotopes. Field performance of the sampling device was tested using a groundwater well in Vienna and results were in excellent agreement with those obtained from the conventional copper tube sampling method. © 2012, National Ground Water Association.

  4. Preparation of Bovine Serum Albumin (BSA) nanoparticles by desolvation using a membrane contactor: a new tool for large scale production.

    PubMed

    Yedomon, B; Fessi, H; Charcosset, C

    2013-11-01

    Albumin nanoparticles are attractive drug delivery systems as they can be prepared under soft conditions and incorporate several kinds of molecules. The aim of this study was to upscale the desolvation process for preparing Bovine Serum Albumin (BSA) nanoparticles using a membrane contactor. At a first step, the BSA nanoparticles were prepared at small scale using a syringe pump. BSA nanoparticles of 139 nm in size, with a polydispersity index of 0.046, were obtained at the optimal conditions: pH 8.2, 100 mg mL(-1) BSA albumin solution (2 mL), and 1 mL min(-1) flow rate of ethanol addition (8 mL). The upscaling with a membrane contactor was achieved by permeating ethanol through the pores of a Shirasu Porous Glass (SPG Technology Co., Japan) membrane and circulating the aqueous phase tangentially to the membrane surface. By increasing the pressure of the ethanol from 1 to 2.7 bars, a progressive decrease in nanoparticle size was obtained with a high nanoparticles yield (around 94-96%). In addition, the flow rate of the circulating phase did not affect the BSA nanoparticle characteristics. At the optimal conditions (pH 8.2, 100 mg mL(-1) BSA albumin solution, pressure of ethanol 2.7 bars, flow rate of the circulating phase 30.7 mL s(-1)), the BSA nanoparticles showed similar characteristics to those obtained with the syringe pump. Large batches of BSA nanoparticles were prepared up to 10 g BSA. The BSA nanoparticles were stable at least during 2 months at 4 °C, and their characteristics were reproducible. It was then concluded that the membrane contactor technique could be a suitable method for the preparation of albumin nanoparticles at large scale with properties similar to that obtained at small scale.

  5. Ammonia removal in the carbon contactor of a hybrid membrane process.

    PubMed

    Stoquart, Céline; Servais, Pierre; Barbeau, Benoit

    2014-12-15

    The hybrid membrane process (HMP) coupling powdered activated carbon (PAC) and low-pressure membrane filtration is emerging as a promising new option to remove dissolved contaminants from drinking water. Yet, defining optimal HMP operating conditions has not been confirmed. In this study, ammonia removal occurring in the PAC contactor of an HMP was simulated at lab-scale. Kinetics were monitored using three PAC concentrations (1-5-10 g L(-1)), three PAC ages (0-10-60 days), two temperatures (7-22 °C), in ambient influent condition (100 μg N-NH4 L(-1)) as well as with a simulated peak pollution scenario (1000 μg N-NH4L(-1)). The following conclusions were drawn: i) Using a colonized PAC in the HMP is essential to reach complete ammonia removal, ii) an older PAC offers a higher resilience to temperature decrease as well as lower operating costs; ii) PAC concentration inside the HMP reactor is not a key operating parameter as under the conditions tested, PAC colonization was not limited by the available surface; iii) ammonia flux limited biomass growth and iv) hydraulic retention time was a critical parameter. In the case of a peak pollution, the process was most probably phosphate-limited but a mixed adsorption/nitrification still allowed reaching a 50% ammonia removal. Finally, a kinetic model based on these experiments is proposed to predict ammonia removal occurring in the PAC reactor of the HMP. The model determines the relative importance of the adsorption and biological oxidation of ammonia on colonized PAC, and demonstrates the combined role of nitrification and residual adsorption capacity of colonized PAC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Modeling the Transverse Shell-side Mass Transfer in Hollow Fiber Membrane Contactors at Low Reynolds Numbers

    NASA Astrophysics Data System (ADS)

    Kirsch, V. A.; Volkov, V. V.; Bildukevich, A. V.

    A method for calculating the external mass transfer in a contactor with a transverse confined flow of a viscous incompressible liquid (gas) past hollow fibers at low Reynolds numbers is proposed. The method is based on the concept of regular arrays of parallel fibers with a well-defined flowfield. As a simplest model system, a row of parallel fibers is considered, for which dependences of a drag force and an efficiency of a solute retention on the inter-fiber distance, membrane mass transfer coefficient, Peclet and Reynolds numbers are computed. The influence of the fluid inertia on the mass transport is studied. It is shown that a linear Stokes equations can be used for as higher Re numbers, as denser is the fiber array. In this case the flow field is independent on the Re number, and analytical solutions for the flowfield and fiber sorption efficiency (fiber Sherwood number) can be used.

  7. Liquid-phase membrane extraction of targeted pesticides from manufacturing wastewaters in a hollow fibre contactor with feed-stream recycle.

    PubMed

    Đorđević, Jelena; Vladisavljević, Goran T; Trtić-Petrović, Tatjana

    2017-01-01

    A two-phase membrane extraction in a hollow fibre contactor with feed-stream recycle was applied to remove selected pesticides (tebufenozide, linuron, imidacloprid, acetamiprid and dimethoate) from their mixed aqueous solutions. The contactor consisted of 50 polypropylene hollow fibres impregnated with 5% tri-n-octylphosphine oxide in di-n-hexyl ether. For low-polar pesticides with log P ≥ 2 (tebufenozide and linuron), the maximum removal efficiency increased linearly from 85% to 96% with increasing the feed flow rate. The maximum removal efficiencies of more polar pesticides were significantly higher under feed recirculation (86%) than in a continuous single-pass operation (30%). It was found from the Wilson's plot that the mass transfer resistance of the liquid membrane can be neglected for low-polar pesticides. The pesticide removals from commercial formulations were similar to those from pure pesticide solutions, indicating that built-in adjuvants did not affect the extraction process.

  8. A system for field gas-extraction of 85Kr, 39Ar and 81Kr using SuperPhobic membrane contactors

    NASA Astrophysics Data System (ADS)

    Burk, L.; Suckow, A.; Cook, P.; Mathouchanh, E.

    2013-12-01

    Radioactive noble gas isotopes are established tools for assessing groundwater movement and transport processes on time scales of decades (85Kr), centuries (39Ar) and many millenia (81Kr). While the atomic trap trace analysis (ATTA) technology promises small sample sizes for these isotopes, field gas extraction will remain the method of choice for several years to come. Recently CSIRO obtained decommissioned radiocarbon gas proportional counters and targets to use them for 85Kr. We aim for a sample size of 50μL Kr corresponding to the gas extracted from 500-1000L water. Flinders University and CSIRO have developed a field-deployable extraction system for large volume gas-extraction in the field. It uses two membrane contactors (MEMBRANA SuperPhobic 4x13) allowing flow rates of up to 50L/min in serial mode. Switching to parallel flow through both contactors is possible, allowing even higher water flow rates. The system automatically logs water temperature, water pressure, water flow rate, gas pressure of the sample, vacuum pressure at the contactor and all valve states, using an Endress + Hauser RSG40 Memograph M. The use of SuperPhobic contactors results in ten times less water in the gas fraction than reported for earlier systems. With the two contactors in serial configuration, gas extraction efficiencies, determined for O2, N2 and Ar, are better than 95% at 5L/min water flow. They are still above 80% for flow rates up to 20L/min in parallel configuration for O2, N2 and Ar. No measurable isotopic fractionation of the target isotope ratios of argon and krypton is to be expected at these high extraction efficiencies.

  9. New photocatalytic contactors obtained by PECVD deposition of TiO 2 thin layers on the surface of macroporous supports. PECVD TiO2-based membranes as photocatalytic contactors

    NASA Astrophysics Data System (ADS)

    Zhou, M.; Roualdès, S.; Ayral, A.

    2015-07-01

    Two different kinds of PECVD anatase-based composite membranes have been successfully prepared by PECVD synthesis (at 150 °C)/post-annealing (at 300 °C) of a titania film deposited on macroporous supports as a top-layer or a skin-coverage. Photocatalytic activity of PECVD anatase films has been proved performing Pilkington test and methylene blue degradation determination in a lab-scale diffusion cell. Measurements of methylene blue degradation and water flow in a pilot-scale dynamic unit have enabled to show the performance of PECVD anatase-based membranes in terms of permeation and photocatalytic properties. Whereas bi-layered membranes present higher photo-degradation ability (up to 2.5 × 10-8 mol s-1 m-2 destroyed methylene blue moles per unit of time and of membrane surface area), skin-covered membranes are characterized by higher water permeance (up to 6800 L h-1 m-2 bar-1). So both kinds of membranes should have an interest as photocatalytic contactors.

  10. Centrifugal Contactor Efficiency Measurements

    SciTech Connect

    Mincher, Bruce Jay; Tillotson, Richard Dean; Grimes, Travis Shane

    2017-01-01

    The contactor efficiency of a 2-cm acrylic centrifugal contactor, fabricated by ANL using 3D printer technology was measured by comparing a contactor test run to 5-min batch contacts. The aqueous phase was ~ 3 ppm depleted uranium in 3 M HNO3, and the organic phase was 1 M DAAP/dodecane. Sampling during the contactor run showed that equilibrium was achieved within < 3 minutes. The contactor efficiency at equilibrium was 95% to 100 %, depending on flowrate.

  11. Recovery of ammonia from domestic wastewater effluents as liquid fertilizers by integration of natural zeolites and hollow fibre membrane contactors.

    PubMed

    Sancho, I; Licon, E; Valderrama, C; de Arespacochaga, N; López-Palau, S; Cortina, J L

    2017-04-15

    The integration of up-concentration processes to increase the efficiency of primary sedimentation, as a solution to achieve energy neutral wastewater treatment plants, requires further post-treatment due to the missing ammonium removal stage. This study evaluated the use of zeolites as a post-treatment step, an alternative to the biological removal process. A natural granular clinoptilolite zeolite was evaluated as a sorbent media to remove low levels (up to 100mg-N/L) of ammonium from treated wastewater using batch and fixed bed columns. After being activated to the Na-form (Z-Na), the granular zeolite shown an ammonium exchange capacity of 29±0.8mgN-NH4(+)/g in single ammonium solutions and 23±0.8mgN-NH4(+)/g in treated wastewater simulating up-concentration effluent at pH=8. The equilibrium removal data were well described by the Langmuir isotherm. The ammonium adsorption into zeolites is a very fast process when compared with polymeric materials (zeolite particle diffusion coefficient around 3×10(-12)m(2)/s). Column experiments with solutions containing 100mgN-NH4(+)/L provide effective sorption and elution rates with concentration factors between 20 and 30 in consecutive operation cycles. The loaded zeolite was regenerated using 2g NaOH/L solution and the rich ammonium/ammonia concentrates 2-3g/L in NaOH were used in a liquid-liquid membrane contactor system in a closed-loop configuration with nitric and phosphoric acid as stripping solutions. The ammonia recovery ratio exceeded 98%. Ammonia nitrate and di-ammonium phosphate concentrated solutions reached up to 2-5% wt. of N.

  12. Large-scale preparation of clove essential oil and eugenol-loaded liposomes using a membrane contactor and a pilot plant.

    PubMed

    Sebaaly, Carine; Greige-Gerges, Hélène; Agusti, Géraldine; Fessi, Hatem; Charcosset, Catherine

    2016-01-01

    Based on our previous study where optimal conditions were defined to encapsulate clove essential oil (CEO) into liposomes at laboratory scale, we scaled-up the preparation of CEO and eugenol (Eug)-loaded liposomes using a membrane contactor (600 mL) and a pilot plant (3 L) based on the principle of ethanol injection method, both equipped with a Shirasu Porous Glass membrane for injection of the organic phase into the aqueous phase. Homogenous, stable, nanometric-sized and multilamellar liposomes with high phospholipid, Eug loading rates and encapsulation efficiency of CEO components were obtained. Saturation of phospholipids and drug concentration in the organic phase may control the liposome stability. Liposomes loaded with other hydrophobic volatile compounds could be prepared at large scale using the ethanol injection method and a membrane for injection.

  13. Membrane bioreactor with a porous hydrophobic membrane as a gas-liquid contactor for waste gas treatment

    SciTech Connect

    Reij, M.W.; Gooijer, K.D. de; Bont, J.A.M. de; Hartmans, S. )

    1995-01-20

    A novel type of bioreactor for waste gas treatment has been designed. The reactor contains a microporous hydrophobic membrane to create a large interface between the waste gas and the aqueous phase. To test the new reactor, propene was chosen because of its high air/water partition coefficient, which causes a low water concentration and hampers its removal from air. Propene transfer from air to a suspension of propene-utilizing Xanthobacter Py2 cells in the membrane bioreactor proved to be controlled by mass transfer in the liquid phase. The resistance of the membrane was negligible. Simulated propene transfer rates agreed well with the experimental data. A stable biofilm of Xanthobacter Py2 developed on the membrane during prolonged operation. The propene flux into the biofilm was 1 [times] 10[sup [minus]6] mol m[sup [minus]2] s[sup [minus]1] at a propene concentration of 9.3 [times] 10[sup [minus]2] mol m[sup [minus]3] in the gas phase.

  14. Improvement of anaerobic digestion performance by continuous nitrogen removal with a membrane contactor treating a substrate rich in ammonia and sulfide.

    PubMed

    Lauterböck, B; Nikolausz, M; Lv, Z; Baumgartner, M; Liebhard, G; Fuchs, W

    2014-04-01

    The effect of reduced ammonia levels on anaerobic digestion was investigated. Two reactors were fed with slaughterhouse waste, one with a hollow fiber membrane contractor for ammonia removal and one without. Different organic loading rates (OLR) and free ammonia and sulfide concentrations were investigated. In the reactor with the membrane contactor, the NH4-N concentration was reduced threefold. At a moderate OLR (3.1 kg chemical oxygen demand - COD/m(3)/d), this reactor performed significantly better than the reference reactor. At high OLR (4.2 kg COD/m(3)/d), the reference reactor almost stopped producing methane (0.01 Nl/gCOD). The membrane reactor also showed a stable process with a methane yield of 0.23 Nl/g COD was achieved. Both reactors had predominantly a hydrogenotrophic microbial consortium, however in the membrane reactor the genus Methanosaeta (acetoclastic) was also detected. In general, all relevant parameters and the methanogenic consortium indicated improved anaerobic digestion of the reactor with the membrane. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Clove essential oil-in-cyclodextrin-in-liposomes in the aqueous and lyophilized states: From laboratory to large scale using a membrane contactor.

    PubMed

    Sebaaly, Carine; Charcosset, Catherine; Stainmesse, Serge; Fessi, Hatem; Greige-Gerges, Hélène

    2016-03-15

    This work is dedicated to prepare liposomal dry powder formulations of inclusion complexes of clove essential oil (CEO) and its main component eugenol (Eug). Ethanol injection method and membrane contactor were applied to prepare liposomes at laboratory and large scale, respectively. Various liposomal formulations were tested: (1) free hydroxypropyl-β-cyclodextrin loaded liposomes; (2) drug in hydroxypropyl-β-cyclodextrin in liposomes (DCL); (3) DCL2 obtained by double loading technique, where the drug is added in the organic phase and the inclusion complex in the aqueous phase. Liposomes were characterized for their particle size, polydispersity index, Zeta potential, morphology, encapsulation efficiency of CEO components and Eug loading rate. Reproducible results were obtained with both injection devices. Compared to Eug-loaded liposomes, DCL and DCL2 improved the loading rate of Eug and possessed smaller vesicles size. The DPPH(•) scavenging activity of Eug and CEO was maintained upon incorporation of Eug and CEO into DCL and DCL2. Contrary to DCL2, DCL formulations were stable after 1 month of storage at 4°C and upon reconstitution of the dried lyophilized cakes. Hence, DCL in aqueous and lyophilized forms, are considered as a promising carrier system to preserve volatile and hydrophobic drugs enlarging their application in cosmetic, pharmaceutical and food industries. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Quantifying the loss of methane through secondary gas mass transport (or 'slip') from a micro-porous membrane contactor applied to biogas upgrading.

    PubMed

    McLeod, Andrew; Jefferson, Bruce; McAdam, Ewan J

    2013-07-01

    Secondary gas transport during the separation of a binary gas with a micro-porous hollow fibre membrane contactor (HMFC) has been studied for biogas upgrading. In this application, the loss or 'slip' of the secondary gas (methane) during separation is a known concern, specifically since methane possesses the intrinsic calorific value. Deionised (DI) water was initially used as the physical solvent. Under these conditions, carbon dioxide (CO2) and methane (CH4) absorption were dependent upon liquid velocity (V(L)). Whilst the highest CO2 flux was recorded at high V(L), selectivity towards CO2 declined due to low residence times and a diminished gas-side partial pressure, and resulted in slip of approximately 5.2% of the inlet methane. Sodium hydroxide was subsequently used as a comparative chemical absorption solvent. Under these conditions, CO2 mass transfer increased by increasing gas velocity (VG) which is attributed to the excess of reactive hydroxide ions present in the solvent, and the fast conversion of dissolved CO2 to carbonate species reinitiating the concentration gradient at the gas-liquid interface. At high gas velocities, CH4 slip was reduced to 0.1% under chemical conditions. Methane slip is therefore dependent upon whether the process is gas phase or liquid phase controlled, since methane mass transport can be adequately described by Henry's law within both physical and chemical solvents. The addition of an electrolyte was found to further retard CH4 absorption via the salting out effect. However, their applicability to physical solvents is limited since electrolytic concentration similarly impinges upon the solvents' capacity for CO2. This study illustrates the significance of secondary gas mass transport, and furthermore demonstrates that gas-phase controlled systems are recommended where greater selectivity is required.

  17. Plasma contactor research, 1990

    NASA Technical Reports Server (NTRS)

    Williams, John D.; Wilbur, Paul J.

    1991-01-01

    Emissive and Langmuir probes were used to measure plasma potential profiles, plasma densities, electron energy distributions, and plasma noise levels near a hollow cathode-based plasma contactor emitting electrons. The effects of electron emission current (100 to 1500 mA) and contactor flowrate (2 to 10 sccm (Xenon)) on these data are examined. Retarding potential analyzer (RPA) measurements showing that high energy ions generally stream from a contactor along with the electrons being emitted are also presented, and a mechanism by which this occurs is postulated. This mechanism, which involves a high rate of ionization induced between electrons and atoms flowing together from the hollow cathode orifice, results in a region of high positive space charge and high positive potential. Langmuir and RPA probe data suggests that both electrons and ions expand spherically from this potential hill region. In addition to experimental observations, a simple one-dimensional model which describes the electron emission process and predicts the phenomena just mentioned is presented and is shown to agree qualitatively with these observations. Experimental results of the first stage of bilateral cooperation with the Italian Institute of Interplanetary Space Physics (IFSI CNR) are presented. Sharp, well-defined double layers were observed downstream of a contactor collecting electrons from an ambient plasma created in the IFSI Facility. The voltage drop across these double layers was observed to increase with the current drawn from the ambient plasma. This observation, which was not as clear in previous IFSI tests conducted at higher neutral pressures, is in agreement with previous experimental observations made at both Colorado State University and NASA Lewis Research Center. Greater double layer voltage drops, multiple double layers, and higher noise levels in the region near the double layers were also observed when a magnetic field was imposed and oriented perpendicular to the

  18. Plasma contactors for electrodynamic tether

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Wilbur, Paul J.

    1986-01-01

    The role plasma contactors play in effective electrodynamic tether operation is discussed. Hollow cathodes and hollow cathode-based plasma sources have been identified as leading candidates for the electrodynamic tether plasma contactor. Present experimental efforts to evaluate the suitability of these devices as plasma contactors, conducted concurrently at NASA Lewis Research Center and Colorado State University, are reviewed. These research programs include the definition of preliminary plasma contactor designs, and the characterization of their operation both as electron emitters and electron collectors to and from a simulated space plasma. Results indicate that ampere-level electron currents, sufficient for electrodynamic tether operation, can be exchanged between hollow cathode-based plasma contactors and a dilute plasma.

  19. Isolation contactor state control system

    DOEpatents

    Bissontz, Jay E.

    2017-05-16

    A controller area network (CAN) installed on a hybrid electric vehicle provides one node with control of high voltage power distribution system isolation contactors and the capacity to energize a secondary electro-mechanical relay device. The output of the secondary relay provides a redundant and persistent backup signal to the output of the node. The secondary relay is relatively immune to CAN message traffic interruptions and, as a result, the high voltage isolation contactor(s) are less likely to transition open in the event that the intelligent output driver should fail.

  20. Testing of pyrochemical centrifugal contactors

    SciTech Connect

    Chow, L.S.; Carls, E.L.; Basco, J.K.; Johnson, T.R.

    1996-08-01

    A centrifugal contactor that performs oxidation and reduction exchange reactions between molten metals and salts at 500 degrees Centigrade has been tested successfully at Argonne National Laboratory (ANL). The design is based on contactors for aqueous- organic systems operation near room temperature. In tests to demonstrate the performance of the pyrocontactor, cadmium and LICl- KCl eutectic salt were the immiscible solvent phases, and rare earths were the distributing solutes. The tests showed that the pyrocontactor mixed and separated the phases well, with stage efficiencies approaching 99% at rotor speeds near 2700 rpm. The contactor ran smoothly and reliably over the entire range of speeds that was tested.

  1. Plasma contactor research - 1991

    NASA Technical Reports Server (NTRS)

    Buchholtz, Brett; Williams, John D.; Wilbur, Paul J.

    1992-01-01

    A report describing the operating principles of hollow-cathode-based plasma contactors emitting or collecting electrons from an ambient plasma is summarized. Preliminary experiments conducted to determine the noise generated by these plasma contactors in the emission-current return line and in the plasma near it are described. These noise data are measured as current fluctuations in the return line and to the Langmuir probe and then analyzed using a fast Fourier transform technique. The spectral compositions of the data are characterized using power spectral density plots which are examined to identify possible noise source(s) and production mechanism(s). The precautions taken in the construction and calibration of the instrumentation to assure adequate frequency response are described. Experimental results show that line-current noise levels are typically 2 percent of the electron current being emitted or collected. However, noise levels increase to as much as 20 percent of the electron current at a few electron-collection operating conditions. The frequencies associated with most of the noise were harmonics of the 60 Hz input to system power supplies. Plasma noise had characteristics similar in magnitude and frequency to those for the return-line noise, but they contained additional features at frequencies considered to be related to ion-acoustic instabilities. Also discussed is a new probe positioning system built to facilitate future plasma-contractor research.

  2. FLUID CONTACTOR APPARATUS

    DOEpatents

    Spence, R.; Streeton, R.J.W.

    1956-04-17

    The fluid contactor apparatus comprises a cylindrical column mounted co- axially and adapted to rotate within a cylindrical vessel, for the purpose of extracting a solute from am aqueous solution by means of an organic solvent. The column is particularly designed to control the vortex pattern so as to reduce the height of the vortices while, at the same time, the width of the annular radius in the radial direction between the vessel and column is less than half the radius of the column. A plurality of thin annular fins are spaced apart along the rotor approximately twice the radial dimension of the column such that two contrarotating substantially circular vortices are contained within each pair of fins as the column is rotated.

  3. Contactor/filter improvements

    DOEpatents

    Stelman, D.

    1988-06-30

    A contactor/filter arrangement for removing particulate contaminants from a gaseous stream is described. The filter includes a housing having a substantially vertically oriented granular material retention member with upstream and downstream faces, a substantially vertically oriented microporous gas filter element, wherein the retention member and the filter element are spaced apart to provide a zone for the passage of granular material therethrough. A gaseous stream containing particulate contaminants passes through the gas inlet means as well as through the upstream face of the granular material retention member, passing through the retention member, the body of granular material, the microporous gas filter element, exiting out of the gas outlet means. A cover screen isolates the filter element from contact with the moving granular bed. In one embodiment, the granular material is comprised of porous alumina impregnated with CuO, with the cover screen cleaned by the action of the moving granular material as well as by backflow pressure pulses. 6 figs.

  4. Plasma contactor development for Space Station

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Hamley, John A.; Sarmiento, Charles J.; Manzella, David H.; Sarver-Verhey, Timothy; Soulas, George C.; Nelson, Amy

    1993-01-01

    Plasma contactors have been baselined for the Space Station (SS) to control the electrical potentials of surfaces to eliminate/mitigate damaging interactions with the space environment. The system represents a dual-use technology which is a direct outgrowth of the NASA electric propulsion program and, in particular, the technology development effort on ion thrustor systems. The plasma contactor subsystems include the plasma contactor unit, a power electronics unit, and an expellant management unit. Under this pre-flight development program these will all be brought to breadboard or engineering model status. Development efforts for the plasma contactor include optimizing the design and configuration of the contactor, validating its required lifetime, and characterizing the contactor plume and electromagnetic interference. The plasma contactor unit design selected for the SS is an enclosed keeper, xenon hollow cathode plasma source. This paper discusses the test results and development status of the plasma contactor unit subsystem for the SS.

  5. Contactor/filter improvements

    DOEpatents

    Stelman, David

    1989-01-01

    A contactor/filter arrangement for removing particulate contaminants from a gaseous stream includes a housing having a substantially vertically oriented granular material retention member with upstream and downstream faces, a substantially vertically oriented microporous gas filter element, wherein the retention member and the filter element are spaced apart to provide a zone for the passage of granular material therethrough. The housing further includes a gas inlet means, a gas outlet means, and means for moving a body of granular material through the zone. A gaseous stream containing particulate contaminants passes through the gas inlet means as well as through the upstream face of the granular material retention member, passing through the retention member, the body of granular material, the microporous gas filter element, exiting out of the gas outlet means. Disposed on the upstream face of the filter element is a cover screen which isolates the filter element from contact with the moving granular bed and collects a portion of the particulates so as to form a dust cake having openings small enough to exclude the granular material, yet large enough to receive the dust particles. In one embodiment, the granular material is comprised of prous alumina impregnated with CuO, with the cover screen cleaned by the action of the moving granular material as well as by backflow pressure pulses.

  6. Electric vehicle drive train with contactor protection

    DOEpatents

    Konrad, C.E.; Benson, R.A.

    1994-11-29

    A drive train for an electric vehicle includes a traction battery, a power drive circuit, a main contactor for connecting and disconnecting the traction battery and the power drive circuit, a voltage detector across contacts of the main contactor, and a controller for controlling the main contactor to prevent movement of its contacts to the closed position when the voltage across the contacts exceeds a predetermined threshold, to thereby protect the contacts of the contactor. The power drive circuit includes an electric traction motor and a DC-to-AC inverter with a capacitive input filter. The controller also inhibits the power drive circuit from driving the motor and thereby discharging the input capacitor if the contacts are inadvertently opened during motoring. A precharging contactor is controlled to charge the input filter capacitor prior to closing the main contactor to further protect the contacts of the main contactor. 3 figures.

  7. Electric vehicle drive train with contactor protection

    DOEpatents

    Konrad, Charles E.; Benson, Ralph A.

    1994-01-01

    A drive train for an electric vehicle includes a traction battery, a power drive circuit, a main contactor for connecting and disconnecting the traction battery and the power drive circuit, a voltage detector across contacts of the main contactor, and a controller for controlling the main contactor to prevent movement of its contacts to the closed position when the voltage across the contacts exceeds a predetermined threshold, to thereby protect the contacts of the contactor. The power drive circuit includes an electric traction motor and a DC-to-AC inverter with a capacitive input filter. The controller also inhibits the power drive circuit from driving the motor and thereby discharging the input capacitor if the contacts are inadvertently opened during motoring. A precharging contactor is controlled to charge the input filter capacitor prior to closing the main contactor to further protect the contacts of the main contactor.

  8. Space plasma contactor research, 1987

    NASA Technical Reports Server (NTRS)

    Wilbur, Paul J.

    1988-01-01

    A simple model describing the process of electron collection from a low pressure ambient plasma in the absence of magnetic field and contactor velocity effects is presented. Experimental measurments of the plasma surrounding the contactor are used to demonstrate that a double-sheath generally develops and separates the ambient plasma from a higher density, anode plasma located adjacent to the contactor. Agreement between the predictions of the model and experimental measurements obtained at the electron collection current levels ranging to 1 A suggests the surface area at the ambient plasma boundary of the double-sheath is equal to the electron current being collected divided by the ambient plasma random electron current density; the surface area of the higher density anode plasma boundary of the double-sheath is equal to the ion current being emitted across this boundary divided by the ion current density required to sustain a stable sheath; and the voltage drop across the sheath is determined by the requirement that the ion and electron currents counterflowing across the boundaries be at space-charge limited levels. The efficiency of contactor operation is shown to improve when significant ionization and excitation is induced by electrons that stream from the ambient plasma through the double-sheath and collide with neutral atoms being supplied through the hollow cathode.

  9. ENGINEERING BULLETIN: ROTATING BIOLOGICAL CONTACTORS

    EPA Science Inventory

    Rotating biological contactors employ aerobic fixed-film treatment to degrade either organic and/or nitrogenous (ammonia-nitrogen) constituents present in aqueous waste streams. ixed-film systems provide a surface to which the biomass can adhere. Treatment is achieved as the wast...

  10. New 3-dimensional CFD modeling of CO2 and H2S simultaneous stripping from water within PVDF hollow fiber membrane contactor

    NASA Astrophysics Data System (ADS)

    Bahlake, Ahmad; Farivar, Foad; Dabir, Bahram

    2016-07-01

    In this paper a 3-dimensional modeling of simultaneous stripping of carbon dioxide (CO2) and hydrogen sulfide (H2S) from water using hollow fiber membrane made of polyvinylidene fluoride is developed. The water, containing CO2 and H2S enters to the membrane as feed. At the same time, pure nitrogen flow in the shell side of a shell and tube hollow fiber as the solvent. In the previous methods of modeling hollow fiber membranes just one of the membranes was modeled and the results expand to whole shell and tube system. In this research the whole hollow fiber shell and tube module is modeled to reduce the errors. Simulation results showed that increasing the velocity of solvent flow and decreasing the velocity of the feed are leads to increase in the system yield. However the effect of the feed velocity on the process is likely more than the influence of changing the velocity of the gaseous solvent. In addition H2S stripping has higher yield in comparison with CO2 stripping. This model is compared to the previous modeling methods and shows that the new model is more accurate. Finally, the effect of feed temperature is studied using response surface method and the operating conditions of feed temperature, feed velocity, and solvent velocity is optimized according to synergistic effects. Simulation results show that, in the optimum operating conditions the removal percentage of H2S and CO2 are 27 and 21 % respectively.

  11. Mass Transfer in 12-CM Centrifugal Contactors

    SciTech Connect

    Chesna, J.C.

    2001-06-26

    One eight-stage unit (8-pack) of centrifugal contactors was tested in both extraction and stripping modes. Efficiencies approaching 100 percent were obtained in both modes. The contactors were operated successfully at a wide range of combined flow rates, including the HEF conditions. This report discusses the results of that test.

  12. Plasma contactor technology for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Hamley, John A.; Sarver-Verhey, Timothy; Soulas, George C.; Parkes, James; Ohlinger, Wayne L.; Schaffner, Michael S.; Nelson, Amy

    1993-01-01

    Hollow cathode plasma contactors were baselined for Space Station Freedom (SSF) to control the electrical potentials of surfaces to eliminate/mitigate damaging interactions with the space environment. The system represents a dual-use technology which is a direct outgrowth of the NASA electric propulsion program and in particular the technology development effort on ion thruster systems. Specific efforts include optimizing the design and configuration of the contactor, validating its required lifetime, and characterizing the contactor plume and electromagnetic interference. The plasma contact or subsystems include the plasma contact or unit, a power electronics unit, and an expellant management unit. Under this program these will all be brought to breadboard and engineering model development status. New test facilities were developed, and existing facilities were augmented, to support characterizations and life testing of contactor components and systems. The magnitude, scope, and status of the plasma contactor hardware development program now underway and preliminary test results on system components are discussed.

  13. Research on the displacement control method of asynchronous modular contactor

    NASA Astrophysics Data System (ADS)

    He, Gong; Ming, Zong

    2017-01-01

    Ac contactor is a kind of low voltage electrical appliances with large usage and wide application. Because of the frequent operation, contactor life must be long enough to ensure the reliable operation of power system. The electrical life of the contactor, as the key to affect the service life of the contactor, is mainly affected by the arc developed in the breaking and closing course. This paper concentrates on a new type of asynchronous modular contactor. To get the contactor movement characteristics, the dynamic model of the electromagnetic system is established by MATLAB/SIMULINK. Then, according to the displacement curve of contactor, the breaking process and closing process is planned. The thought of closed loop control, by adjusting the parameters of PID controller, enables the contactor to operate as the planning displacement curve. In addition, to achieve no arc or micro arc breaking and no bounce or micro bounce closing , a displacement closed loop control system for contactor is designed.

  14. A Scale for Rating Fire-Prevention Contactors

    Treesearch

    M.L. Doolittle

    1979-01-01

    A scale is constructed to help fire-prevention program administrators determine if an individual contactor is effective at influencing people. The 24 items in the scale indicate the qualities that an effective contactor should have.

  15. Nonlinear Poisson-Boltzmann model of charged lipid membranes: Accounting for the presence of zwitterionic lipids

    NASA Astrophysics Data System (ADS)

    Mengistu, Demmelash H.; May, Sylvio

    2008-09-01

    The nonlinear Poisson-Boltzmann model is used to derive analytical expressions for the free energies of both mixed anionic-zwitterionic and mixed cationic-zwitterionic lipid membranes as function of the mole fraction of charged lipids. Accounting explicitly for the electrostatic properties of the zwitterionic lipid species affects the free energy of anionic and cationic membranes in a qualitatively different way: That of an anionic membrane changes monotonously as a function of the mole fraction of charged lipids, whereas it passes through a pronounced minimum for a cationic membrane.

  16. High-current plasma contactor neutralizer system

    NASA Technical Reports Server (NTRS)

    Beattie, J. R.; Williamson, W. S.; Matossian, J. N.; Vourgourakis, E. J.; Burch, J. L.

    1989-01-01

    A plasma-contactor neutralizer system is described, for the stabilizing the Orbiter's potential during flights of the Atmospheric Laboratory for Applications and Science missions. The plasma contactor neutralizer will include a Xe plasma source that can provide steady-state ion-emission currents of up to 1.5 A. The Orbiter's potential will be maintained near that of the surrounding space plasma during electron-beam accelerator firings through a combination of ion emission from the Xe plasma source and electron collection from the ambient space plasma. Configuration diagrams and block diagrams are presented along with the performance characteristics of the system.

  17. Micro contactor based on isotachophoretic sample transport.

    PubMed

    Goet, Gabriele; Baier, Tobias; Hardt, Steffen

    2009-12-21

    It is demonstrated how isotachophoresis (ITP) in a microfluidic device may be utilized to bring two small sample volumes into contact in a well-controlled manner. The ITP contactor serves a similar purpose as micromixers that are designed to mix two species rapidly in a microfluidic channel. In contrast to many micromixers, the ITP contactor does not require complex channel architectures and allows a sample processing in the spirit of "digital microfluidics", i.e. the samples always remain in a compact volume. It is shown that the ITP zone transport through microchannels proceeds in a reproducible and predictable manner, and that the sample trajectories follow simple relationships obtained from Ohm's law. Firstly, the micro contactor can be used to synchronize two ITP zones having reached a channel at different points in time. Secondly, fulfilling its actual purpose it is capable of bringing two samples in molecular contact via an interpenetration of ITP zones. It is demonstrated that the contacting time is proportional to the ITP zone extension. This opens up the possibility of using that type of device as a special type of micromixer with "mixing times" significantly below one second and an option to regulate the duration of contact through specific parameters such as the sample volume. Finally, it is shown how the micro contactor can be utilized to conduct a hybridization reaction between two ITP zones containing complementary DNA strands.

  18. Hollow cathode-based plasma contactor experiments for electrodynamic tether

    NASA Astrophysics Data System (ADS)

    Patterson, Michael J.

    1987-01-01

    The role plasma contactors play in effective electrodynamic tether operation is discussed. Hollow cathodes and hollow cathode-based plasma sources have been identified as leading candidates for the electrodynamic tether plasma contactor. Present experimental efforts to evaluate the suitability of these devices as plasma contactors are reviewed. This research includes the definition of preliminary plasma contactor designs, and the characterization of their operation as electron collectors from a simulated space plasma. The discovery of an 'ignited mode' regime of high contactor efficiency and low impedance is discussed, as well as is the application of recent models of the plasma coupling process to contactor operation. Results indicate that ampere-level electron currents can be exchanged between hollow cathode-based plasma contactors and a dilute plasma in this regime. A discussion of design considerations for plasma contactors is given which includes expressions defining the total mass flow rate and power requirements of plasma contactors operating in both the cathodic and anodic regimes, and correlation of this to the tether current. Finally, future ground and spaceflight experiments are proposed to resolve critical issues of plasma contactor operation.

  19. Hollow cathode-based plasma contactor experiments for electrodynamic tether

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.

    1987-01-01

    The role plasma contactors play in effective electrodynamic tether operation is discussed. Hollow cathodes and hollow cathode-based plasma sources have been identified as leading candidates for the electrodynamic tether plasma contactor. Present experimental efforts to evaluate the suitability of these devices as plasma contactors are reviewed. This research includes the definition of preliminary plasma contactor designs, and the characterization of their operation as electron collectors from a simulated space plasma. The discovery of an 'ignited mode' regime of high contactor efficiency and low impedance is discussed, as well as is the application of recent models of the plasma coupling process to contactor operation. Results indicate that ampere-level electron currents can be exchanged between hollow cathode-based plasma contactors and a dilute plasma in this regime. A discussion of design considerations for plasma contactors is given which includes expressions defining the total mass flow rate and power requirements of plasma contactors operating in both the cathodic and anodic regimes, and correlation of this to the tether current. Finally, future ground and spaceflight experiments are proposed to resolve critical issues of plasma contactor operation.

  20. Continuous fluidized-bed contactor with recycle of sorbent

    DOEpatents

    Scott, Charles D.; Petersen, James N.; Davison, Brian H.

    1996-01-01

    A continuous fluidized-bed contactor containing sorbent particles is used to remove solutes from liquid solvents. As the sorbent particles, for example gel beads, sorb the solute, for example metal ion species, the sorbent particles tend to decrease in diameter. These smaller loaded sorbent particles rise to the top of the contactor, as larger sorbent particles remain at the bottom of the contactor as a result of normal hydraulic forces. The smaller loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor. Alternatively, the loaded sorbent particles may also slightly increase in diameter, or exhibit no change in diameter but an increase in density. As a result of normal hydraulic forces the larger loaded sorbent particles fall to the bottom of the contactor. The larger loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor.

  1. Continuous fluidized-bed contactor with recycle of sorbent

    DOEpatents

    Scott, C.D.; Petersen, J.N.; Davison, B.H.

    1996-07-09

    A continuous fluidized-bed contactor containing sorbent particles is used to remove solutes from liquid solvents. As the sorbent particles, for example gel beads, sorb the solute, for example metal ion species, the sorbent particles tend to decrease in diameter. These smaller loaded sorbent particles rise to the top of the contactor, and larger sorbent particles remain at the bottom of the contactor as a result of normal hydraulic forces. The smaller loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor. Alternatively, the loaded sorbent particles may also slightly increase in diameter, or exhibit no change in diameter but an increase in density. As a result of normal hydraulic forces the larger loaded sorbent particles fall to the bottom of the contactor. The larger loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor. 8 figs.

  2. Accountability.

    ERIC Educational Resources Information Center

    Lashway, Larry

    1999-01-01

    This issue reviews publications that provide a starting point for principals looking for a way through the accountability maze. Each publication views accountability differently, but collectively these readings argue that even in an era of state-mandated assessment, principals can pursue proactive strategies that serve students' needs. James A.…

  3. Development of a mechanistic model for prediction of CO2 capture from gas mixtures by amine solutions in porous membranes.

    PubMed

    Ghadiri, Mehdi; Marjani, Azam; Shirazian, Saeed

    2017-06-01

    A mechanistic model was developed in order to predict capture and removal of CO2 from air using membrane technology. The considered membrane was a hollow-fiber contactor module in which gas mixture containing CO2 was assumed as feed while 2-amino-2-metyl-1-propanol (AMP) was used as an absorbent. The mechanistic model was developed according to transport phenomena taking into account mass transfer and chemical reaction between CO2 and amine in the contactor module. The main aim of modeling was to track the composition and flux of CO2 and AMP in the membrane module for process optimization. For modeling of the process, the governing equations were computed using finite element approach in which the whole model domain was discretized into small cells. To confirm the simulation findings, model outcomes were compared with experimental data and good consistency was revealed. The results showed that increasing temperature of AMP solution increases CO2 removal in the hollow-fiber membrane contactor.

  4. Extraction and quantification of SO2 content in wines using a hollow fiber contactor.

    PubMed

    Plaza, Andrea; Romero, Julio; Silva, Wladimir; Morales, Elizabeth; Torres, Alejandra; Aguirre, María J

    2014-10-01

    Sulfites [Formula: see text] or sulfur dioxide (SO2) is a preservative widely used in fruits and fruit-derived products. This study aims to propose a membrane contactor process for the selective removal and recovery of SO2 from wines in order to obtain its reliable quantification. Currently, the aspiration and Ripper methods offer a difficult quantification of the sulfite content in red wines because they involve evaporation steps of diluted compounds and a colorimetric assay, respectively. Therefore, an inexpensive and accurate methodology is not currently available for continuous monitoring of SO2 in the liquids food industry. Red wine initially acidified at pH < 1 was treated by membrane extraction at 25 ℃. This operation is based on a hydrophobic Hollow Fiber Contactor, which separates the acidified red wine in the shell side and a diluted aqueous sodium hydroxide solution as receiving solution into the lumenside in countercurrent. Sulfite and bisulfite in the acidified red wine become molecular SO2, which is evaporated through the membrane pores filled with gas. Thus, SO2 is trapped in a colorless solution and the membrane contactor controls its transfer, decreasing experimental error induced in classical methods. Experimental results using model solutions with known concentration values of [Formula: see text] show an average extraction percentage of 98.91 after 4 min. On the other hand, two types of Chilean Cabernet Sauvignon wines were analyzed with the same system to quantify the content of free and total sulfites. Results show a good agreement between these methods and the proposed technique, which shows a lower experimental variability.

  5. Corrosion abatement in sulfuric acid alkylation unit horizontal contactors

    SciTech Connect

    Schutt, H.U.

    1997-09-01

    The need to increase throughput in alkylation plants has resulted in higher operating temperatures and higher water levels in alkylation acids than projected by design. Combined with higher flow rates, the more severe process environment causes carbon steel to corrode at increased rates. Carbon steel is the main material of construction for horizontal contactors (Stratco reactors). A leak to the atmosphere in the hydraulic end cone of one contactor and the realization that basic corrosion data are not available for high throughput process conditions in alkylation units prompted a laboratory study to develop the lacking expertise. Corrosion in alkylation unit horizontal contactors is successfully mitigated by saturating fresh alkylation acid with ferrous sulfate.

  6. Modeling the expansion of a contactor plasma

    NASA Astrophysics Data System (ADS)

    Hogan, E. A.; Delzanno, G.; Camporeale, E.; Borovsky, J. E.; MacDonald, E.; Thomsen, M. F.

    2012-12-01

    Plasma contactor technology is widely used on board spacecraft to keep spacecraft charging levels under control. On the International Space Station, for instance, it is used to prevent high current discharges between differently charged surfaces. It consists of emitting a neutral plasma to create a plasma reservoir near the spacecraft in order to balance the currents collected by the spacecraft from the magnetospheric environment. One approach to modeling the contactor plasma plume applies a self-similar solution in order to gain insight into the plume dynamics without requiring expensive numerical simulations [1, 2]. Typically, hydrodynamic fluid equations are used to model the plasma behavior. We present a comparison of different self-similar plume models existing in the literature [1, 2] and compare these with our Particle-In-Cell simulations in the near-field to assess their validity. We will consider both the unmagnetized and the magnetized limit, treating the magnitude and angle (relative to the plasma injection velocity) of the magnetic field as a parameter. [1] F. F. Gabdullin, A. G. Korsun, E. M. Tverdokhlebova, 'The plasma plume emitted onboard the international space station under the effect of the geomagnetic field', IEEE Trans. Plasma Science 36(5) 2207 (2008). [2] M. Merino, E. Ahedo, C. Bombardelli, H. Urrutxua, J. Pelaez, 'Hypersonic plasma plume expansion in space', 32nd International Electric Propulsion Conference, IEPC-2011-086, Wiesbaden, Germany, 2011.

  7. Model of electron collecting plasma contactors

    NASA Technical Reports Server (NTRS)

    Davis, V. A.; Katz, I.; Mandell, M. J.; Parks, D. E.

    1991-01-01

    In laboratory experiments, plasma contactors are observed to collect ampere-level electron currents with low impedance. In order to extend the laboratory experience to the low-earth-orbit environment, a model of plasma contactors is being developed. Laboratory results are being used to support and validate the model development. The important physical processes observed in the laboratory are that the source plasma is separated from the background plasma by a double layer and that ionization of the expellant gas by the collected electrons creates the bulk of the ions that leave the source plasma. The model, which uses Poisson's equation with a physical charge density that includes the ion and electron components of both the source and the ambient plasmas, reproduces this phenomenon for typical experimental parameters. The calculations, in agreement with the laboratory results, show little convergence of the accelerated electrons. The angular momentum of the incoming electrons dramatically reduces the peak electron density. These electrons ionize enough gas to generate the source plasma. Calculations show that the increase in ionization rate with potential produces a steep rise in collected current with increasing potential as seen in the laboratory.

  8. Modeling the expansion of a contactor plasma

    NASA Astrophysics Data System (ADS)

    Hogan, Erik; Delzanno, Gian Luca; Camporeale, Enrico; Borovsky, Joseph; MacDonald, Elizabeth; Thomsen, Michelle

    2012-10-01

    Plasma contactor technology is widely used on board spacecraft to keep spacecraft charging levels under control. On the International Space Station, for instance, it is used to prevent high current discharges between differently charged surfaces. It consists of emitting a neutral plasma to create a plasma reservoir near the spacecraft in order to balance the currents collected by the spacecraft from the magnetospheric environment. One approach to modeling the contactor plasma plume applies a self-similar solution in order to gain insight into the plume dynamics without requiring expensive numerical simulations [1, 2]. Typically, hydrodynamic fluid equations are used to model the plasma behavior. We present a comparison of different self-similar plume models existing in the literature [1, 2] and compare these with our Particle-In-Cell simulations in the near-field to assess their validity. We will consider both the unmagnetized and the magnetized limit. [4pt] [1] F. F. Gabdullin, A. G. Korsun, E. M. Tverdokhlebova, IEEE Trans. Plasma Science 36(5) 2207 (2008). [2] M. Merino, E. Ahedo, C. Bombardelli, H. Urrutxua, J. Pelaez, ``Hypersonic plasma plume expansion in space,'' 32nd International Electric Propulsion Conference, IEPC-2011-086, Wiesbaden, Germany, 2011.

  9. Accountability,

    DTIC Science & Technology

    1987-05-01

    A186 869 CCOUNTABILITY(U) AIR WAR COLL KAXNELL FB AL / UNCLASSIFI F/G 5/5 U EEEEEEEmohhhiIsoflfflflfl..fflfl ll EEsonE~hh i .~. ~~ 1 p 1 V "p h...n(D LEG 1 0 1987 -0 ACCOIINTABILITY By CHAPLAIN LIEUTENANT COLONEL EDWARD E. GALLOWAY .1T_ *v 4 AIR UNIVERSITY APPROVED FOR PUBLIC UNITED STATES AIR...1scu,;s ion of wlvece andl to(: whloi leadlers ;ire accountable, followedl by an hnistocical gl1imnpse at . 1 ii i Lryi.ad:± rs and how their s3ucces 3e5

  10. A unifying mechanism accounts for sensing of membrane curvature by BAR domains, amphipathic helices and membrane-anchored proteins.

    PubMed

    Bhatia, Vikram Kjøller; Hatzakis, Nikos S; Stamou, Dimitrios

    2010-06-01

    The discovery of proteins that recognize membrane curvature created a paradigm shift by suggesting that membrane shape may act as a cue for protein localization that is independent of lipid or protein composition. Here we review recent data on membrane curvature sensing by three structurally unrelated motifs: BAR domains, amphipathic helices and membrane-anchored proteins. We discuss the conclusion that the curvature of the BAR dimer is not responsible for sensing and that the sensing properties of all three motifs can be rationalized by the physicochemical properties of the curved membrane itself. We thus anticipate that membrane curvature will promote the redistribution of proteins that are anchored in membranes through any type of hydrophobic moiety, a thesis that broadens tremendously the implications of membrane curvature for protein sorting, trafficking and signaling in cell biology.

  11. Plasma contactors for use with electodynamic tethers for power generation

    NASA Technical Reports Server (NTRS)

    Hastings, D. E.; Gatsonis, N. A.

    1988-01-01

    Plasma contactors are proposed as a means of making good electrical contact between biased surfaces such as found at the ends of an electrodynamic tether and the space environment. The plasma contactor emits a plasma cloud which facilitates the electrical connection. The physics of this plasma cloud is investigated for contactors used as electron collectors. The central question addressed is whether the electrons collected by a plasma contactor come from the far field or by ionization of local neutral gas. This question is important because the system implications are different for the two mechanisms. It is shown that contactor clouds in space will consist of a spherical core possibly containing a shock wave. Outside of the core the cloud will expand anisotropically across the magnetic field leading to a turbulent cigar shape structure along the field. This outer region is itself divided into two regions by the ion response to the electric field. A two-dimensional theory for the outer regions of the cloud is developed. The current voltage characteristic of an Argon plasma contactor cloud is estimated for several ion currents in the range of 1 to 100 Amperes. It is suggested that the major source of collected electrons comes by ionization of neutral gas while collection of electrons from the far field is relatively small.

  12. Development of Centrifugal Contactor with High Reliability

    SciTech Connect

    Okamura, Nobuo; Takeuchi, Masayuki; Ogino, Hideki; Kase, Takeshi; Koizumi, Tsutomu

    2007-07-01

    In Japan Atomic Energy Agency (JAEA), an innovative centrifugal contactor system has been developed for a future reprocessing plant. It was confirmed that it had a higher extraction capacity through the uranium test already. But it was necessary that it had the higher mechanical reliability to be applied in a reprocessing plant. In this study, two types of driving units that use a ball bearing or a magnetic bearing have been developed for it. It was confirmed that they had enough abilities trough endurance tests. The driving unit with ball bearing could be operated continuously for 5000 hours that was equal to a term of an annual operation. It was found that it could be operated for a year without maintenance. JAEA will continue to improve them and select more advantageous one on the basis of economy and lifetime in near future. (authors)

  13. Wet air oxidation of formic acid using nanoparticle-modified polysulfone hollow fibers as gas-liquid contactors.

    PubMed

    Hogg, Seth R; Muthu, Satish; O'Callaghan, Michael; Lahitte, Jean-Francois; Bruening, Merlin L

    2012-03-01

    Catalytic wet air oxidation (CWAO) using membrane contactors is attractive for remediation of aqueous pollutants, but previous studies of even simple reactions such as formic acid oxidation required multiple passes through tubular ceramic membrane contactors to achieve high conversion. This work aims to increase single-pass CWAO conversions by using polysulfone (PS) hollow fibers as contactors to reduce diffusion distances in the fiber lumen. Alternating adsorption of polycations and citrate-stabilized platinum colloids in fiber walls provides catalytically active PS hollow fibers. Using a single PS fiber, 50% oxidation of a 50 mM formic acid feed solution results from a single pass through the fiber lumen (15 cm length) with a solution residence time of 40 s. Increasing the number of PS fibers to five while maintaining the same volumetric flow rate leads to over 90% oxidation, suggesting that further scale up in the number of fibers will facilitate high single pass conversions at increased flow rates. The high conversion compared to prior studies with ceramic fibers stems from shorter diffusion distances in the fiber lumen. However, the activity of the Pt catalyst is 20-fold lower than in previous ceramic fibers. Focusing the Pt deposition near the fiber lumen and limiting pore wetting to this region might increase the activity of the catalyst. © 2012 American Chemical Society

  14. ISS Plasma Contactor Units Operations During Strong Geomagnetic Activity

    NASA Astrophysics Data System (ADS)

    Alred, J.; Mikatarian, R.; Barsamian, H.; Minow, J.; Koontz, S.

    2003-12-01

    The large structure and high voltage arrays of the ISS represent a complex system that interacts with the Earth's ionosphere. To mitigate spacecraft charging problems on the ISS, two Plasma Contactor Units discharge ionized xenon gas to "clamp" the potential of the ISS with respect to the low Earth orbit plasma. The Plasma Interaction Model, a model of ISS plasma interaction developed from the basic physics of the interaction phenomena, includes magnetic induction effects, plasma temperature and density effects, interaction of the high voltage solar arrays with ionospheric plasma, and accounts for other conductive areas on the ISS. To augment this model, the PCU discharge current has been monitored for the ISS in a variety of flight attitudes as well as during the annual seasons. A review of the PCU discharge currents shows a correlation to the geomagnetic activity. The variation in the PCU discharge current during strong geomagnetic activity will be presented. Also, the PCU discharge currents during periods of low geomagnetic activity will be discussed. The presentation will conclude with a comparison of satellite plasma measurements during different stages of geomagnetic activity.

  15. Modeling of rotating disc contactor (RDC) column

    NASA Astrophysics Data System (ADS)

    Ismail, Wan Nurul Aiffah; Zakaria, Siti Aisyah; Noor, Nor Fashihah Mohd; Sulong, Ibrahim; Arshad, Khairil Anuar

    2014-12-01

    Liquid-liquid extraction is one of the most important separation processes. Different kinds of liquid-liquid extractor such as Rotating Disc Contactor (RDC) Column being used in industries. The study of liquid-liquid extraction in an RDC column has become a very important subject to be discussed not just among chemical engineers but mathematician as well. In this research, the modeling of small diameter RDC column using the chemical system involving cumene/isobutryric asid/water are analyzed by the method of Artificial Neural Network (ANN). In the previous research, we begin the process of analyzed the data using methods of design of the experiments (DOE) to identify which factor and their interaction factor are significant and to determine the percentage of contribution of the variance for each factor. From the result obtained, we continue the research by discussed the development and validation of an artificial neural network model in estimating the concentration of continuous and concentration of dispersed outlet for an RDC column. It is expected that an efficient and reliable model will be formed to predict RDC column performance as an alternative to speed up the simulation process.

  16. Physical processes associated with current collection by plasma contactors

    NASA Technical Reports Server (NTRS)

    Katz, Ira; Davis, Victoria A.

    1990-01-01

    Recent flight data confirms laboratory observations that the release of neutral gas increases plasma sheath currents. Plasma contactors are devices which release a partially ionized gas in order to enhance the current flow between a spacecraft and the space plasma. Ionization of the expellant gas and the formation of a double layer between the anode plasma and the space plasma are the dominant physical processes. A theory is presented of the interaction between the contactor plasma and the background plasma. The conditions for formation of a double layer between the two plasmas are derived. Double layer formation is shown to be a consequence of the nonlinear response of the plasmas to changes in potential. Numerical calculations based upon this model are compared with laboratory measurements of current collection by hollow cathode-based plasma contactors.

  17. Development of novel contactor for nuclear solvent extraction

    SciTech Connect

    Kumar, Shekhar; Kumar, Rajnish; Sivakumar, D.; Balamurugan, M.; Koganti, S.B.

    2008-07-01

    For current designs of radiochemical plants, solvent-extraction contactors with no periodic maintenance like pulse column are the first choice. In addition, as costs of specialty solvents for nuclear extraction are quite high, there is a demand for operation at extreme phase ratios. Recently a novel mixer-settler was visualized and developed for this kind of service. The mixer of the novel contactor is based on rotated helical tubes and does not involve any mechanical moving part. Mass-transfer runs were carried out with aqueous nitric acid and 30% TBP solvent at A/O of 0.25-200 (in extraction) and A/O of 0.25-10 (in back-extraction mode). The developed contactor exhibited nearly 100% efficiency for all the cases. (authors)

  18. Prognostic and Diagnostic Technology for DC Actuated Contactors and Motor Starters

    NASA Astrophysics Data System (ADS)

    Zhou, Xin; Zou, Lian; Briggs, Roger

    Unpredicted contactor failure can interrupt production and affect the uptime and throughput of manufacturing. Usually the life of a contactor is based on the manufacturers' life test data. However, due to the way of how the contactor is operated and the environment it is operated in, the working life of a contactor can vary significantly. In this paper, a novel technology has been investigated to predict potential failures of DC actuated contactors by monitoring their DC coil current and contactor currents. Three parameters are derived from this set of data to monitor the health of contactors: contact over-travel, armature pull-in time and coil current differential. Contact over-travel provides information on the remaining life of contacts and coil current differential provides indication of contact weld and carrier jam due to debris. The armature pull-in time provides information on contactor closing speed. Prototype contactors have been built and AC4 tests have been carried out for evaluation. Test results show that the contact over-travel parameter agrees well with contact mass loss data taken after contactors failed. The derived armature pull-in time agrees well with that measured by a laser displacement sensor. The defined parameters provide effective monitoring and prediction of potential contactor failures.

  19. Applicability of hydroxylamine nitrate reductant in pulse-column contactors

    SciTech Connect

    Reif, D.J.

    1983-05-01

    Uranium and plutonium separations were made from simulated breeder reactor spent fuel dissolver solution with laboratory-sized pulse column contactors. Hydroxylamine nitrate (HAN) was used for reduction of plutonium (1V). An integrated extraction-partition system, simulating a breeder fuel reprocessing flowsheet, carried out a partial partition of uranium and plutonium in the second contactor. Tests have shown that acceptable coprocessing can be ontained using HAN as a plutonium reductant. Pulse column performance was stable even though gaseous HAN oxidation products were present in the column. Gas evolution rates up to 0.27 cfm/ft/sup 2/ of column cross section were tested and found acceptable.

  20. Cathodes Delivered for Space Station Plasma Contactor System

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.

    1999-01-01

    The International Space Station's (ISS) power system is designed with high-voltage solar arrays that typically operate at output voltages of 140 to 160 volts (V). The ISS grounding scheme electrically ties the habitat modules, structure, and radiators to the negative tap of the solar arrays. Without some active charge control method, this electrical configuration and the plasma current balance would cause the habitat modules, structure, and radiators to float to voltages as large as -120 V with respect to the ambient space plasma. With such large negative floating potentials, the ISS could have deleterious interactions with the space plasma. These interactions could include arcing through insulating surfaces and sputtering of conductive surfaces as ions are accelerated by the spacecraft plasma sheath. A plasma contactor system was baselined on the ISS to prevent arcing and sputtering. The sole requirement for the system is contained within a single directive (SSP 30000, paragraph 3.1.3.2.1.8): "The Space Station structure floating potential at all points on the Space Station shall be controlled to within 40 V of the ionospheric plasma potential using a plasma contactor." NASA is developing this plasma contactor as part of the ISS electrical power system. For ISS, efficient and rapid emission of high electron currents is required from the plasma contactor system under conditions of variable and uncertain current demand. A hollow cathode plasma source is well suited for this application and was, therefore, selected as the design approach for the station plasma contactor system. In addition to the plasma source, which is referred to as a hollow cathode assembly, or HCA, the plasma contactor system includes two other subsystems. These are the power electronics unit and the xenon gas feed system. The Rocketdyne Division of Boeing North American is responsible for the design, fabrication, assembly, test, and integration of the plasma contactor system. Because of

  1. Rotating Biological Contactors (RBC's). Student Manual. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Zickefoose, Charles S.

    This student manual provides the textual material for a unit on rotating biological contactors (RBC's). Topic areas considered include: (1) flow patterns of water through RBC installations; (2) basic concepts (shaft and stage); (3) characteristics of biomass; (4) mechanical features (bearings, mechanical drive systems, and air drive systems); (5)…

  2. Effectiveness of Forestry Agency Personnel as Fire Prevention Contactors

    Treesearch

    M.L. Doolittle

    1980-01-01

    A major responsibility of county forest rangers in North Carolina is fire prevention. Personal contact with the public is essential to the successful performance of this function. A survey of 50 North Carolina rangers revealed that the degree of success for each ranger was directly related to the specific effort put forth as a contactor.

  3. Design Attributes and Scale Up Testing of Annular Centrifugal Contactors

    SciTech Connect

    David H. Meikrantz; Jack D. Law

    2005-04-01

    Annular centrifugal contactors are being used for rapid yet efficient liquid- liquid processing in numerous industrial and government applications. Commercialization of this technology began eleven years ago and now units with throughputs ranging from 0.25 to 700 liters per minute are readily available. Separation, washing, and extraction processes all benefit from the use of this relatively new commercial tool. Processing advantages of this technology include: low in-process volume per stage, rapid mixing and separation in a single unit, connection-in-series for multi-stage use, and a wide operating range of input flow rates and phase ratios without adjustment. Recent design enhancements have been added to simplify maintenance, improve inspection ability, and provide increased reliability. Cartridge-style bearing and mechanical rotary seal assemblies that can include liquid-leak sensors are employed to enhance remote operations, minimize maintenance downtime, prevent equipment damage, and extend service life. Clean-in-place capability eliminates the need for disassembly, facilitates the use of contactors for feed clarification, and can be automated for continuous operation. In nuclear fuel cycle studies, aqueous based separations are being developed that efficiently partition uranium, actinides, and fission products via liquid-liquid solvent extraction. Thus, annular centrifugal contactors are destined to play a significant role in the design of such new processes. Laboratory scale studies using mini-contactors have demonstrated feasibility for many such separation processes but validation at an engineering scale is needed to support actual process design.

  4. Advanced electric propulsion and space plasma contactor research

    NASA Technical Reports Server (NTRS)

    Wilbur, Paul J.

    1987-01-01

    A theory of the plasma contacting process is described and experimental results obtained using three different hollow cathode-based plasma contactors are presented. The existence of a sheath across which the bulk of the voltage drop associated with the contacting process occurs is demonstrated. Test results are shown to agree with a model of a spherical, space-charge-limited double sheath. The concept of ignited mode contactor operation is discussed, which is shown to enhance contactor efficiency when it is collecting electrons. An investigation of the potentials in the plasma plumes downstream of contactors operating at typical conditions is presented. Results of tests performed on hollow cathodes operating at high interelectrode pressures (up to about 1000 Torr) on ammonia are presented and criteria that are necessary to ensure that the cathode will operate properly in this regime are presented. These results suggest that high pressure hollow cathode operation is difficult to achieve and that special care must be taken to assure that the electron emission region remains diffuse and attached to the low work function insert. Experiments conducted to verify results obtained previously using a ring cusp ion source equipped with a moveable anode are described and test results are reported. A theoretical study of hollow cathode operation at high electron emission currents is presented. Preliminary experiments using the constrained sheath optics concept to achieve ion extraction under conditions of high beam current density, low net accelerating voltage and well columniated beamlet formation are discussed.

  5. MEMBRANE BIOTREATMENT OF VOC-LADEN AIR

    EPA Science Inventory

    The paper discusses membrane biotreatment of air laden with volatile organic compounds (VOCs). Microporous flat-sheet and hollow-fiber membrane contactors were used to support air-liquid mass transfer interfaces. These modules were used in a two-step process to transfer VOCs fr...

  6. MEMBRANE BIOTREATMENT OF VOC-LADEN AIR

    EPA Science Inventory

    The paper discusses membrane biotreatment of air laden with volatile organic compounds (VOCs). Microporous flat-sheet and hollow-fiber membrane contactors were used to support air-liquid mass transfer interfaces. These modules were used in a two-step process to transfer VOCs fr...

  7. High Current 270 VDC Contactor and Current Sensor System Design and Development

    DTIC Science & Technology

    1998-09-01

    HVDC contactor. Eaton Corporation has developed a design, completed a critical design review, developed a test plan, constructed the prototype test...4 DISCUSSIONS AND RECOMMENDATIONS, CONCLUSIONS 4.1 Discussions and Recommendations The HVDC contactor incorporates an arc chute with a permanent...power supply failed and required repair. The dielectric withstands voltage of the HVDC contactor was reduced below the acceptable limits of the

  8. Modelling of nitric acid and U(VI) Co-extraction in annular centrifugal contactors

    NASA Astrophysics Data System (ADS)

    Gaubert, E. T.; Jobson, M.; Birket, J. E.; Denniss, I. S.; May, I.

    2000-07-01

    British Nuclear Fuels Limited (BNFL) is currently developing novel flow sheets for an advanced PUREX process using centrifugal contactors. This technology provides two major advantages. Firstly, centrifugal contactors can process high throughputs of liquid, while being an equipment of small size, compared to pulsed columns for example. Secondly, during the reprocessing of actinides with diluted tributyl phosphate (TBP) solutions, centrifugal contactors also minimize solvent hydrolysis and radiolysis because of the very short contact times involved.

  9. Accounting for misalignments and thermal fluctuations in fluorescence correlation spectroscopy experiments on membranes.

    PubMed

    Sanguigno, Luigi; Cosenza, Chiara; Causa, Filippo; Netti, Paolo Antonio

    2013-03-21

    Several authors have exploited the ability of the fluorescence correlation spectroscopy to probe motion at the molecular level. In a couple of decades, all their efforts have allowed the application of this technique even to the diffusion measurement of cellular components. Nowadays, the fluorescence correlation spectroscopy is considered a standard tool to measure diffusion in cells both in vivo and in vitro. Unfortunately, while the interpretation and the set-up have been consolidated for 3D diffusion measurements (i.e. diffusion in an aqueous solution), the experiments carried out on flat elements, such as membranes, show unusually high relative errors. Furthermore, long tail correlations are generally detected and ascribed to diffusion anomalies. The 2D fluorescence correlation measurements have been interpreted under certain hypotheses, whereby the membrane is assumed to be perfectly flat, motionless and aligned with the optical axes. Here, we investigated the robustness of these hypotheses, trying to understand, in an elementary but not trivial way, how misalignments and thermal fluctuations affect the temporal correlation of the intensity fluctuation collected during measurements on membranes.

  10. Remove volatile organic compounds (VOCs) with membrane separation techniques.

    PubMed

    Zhang, Lin; Weng, Huan-xin; Chen, Huan-lin; Gao, Cong-jie

    2002-04-01

    Membrane separation, a new technology for removing VOCs including pervaporation, vapor permeation, membrane contactor, and membrane bioreactor was presented. Comparing with traditional techniques, these special techniques are an efficient and energy-saving technology. Vapor permeation can be applied to recovery of organic solvents from exhaust streams. Membrane contactor could be used for removing or recovering VOCs from air or wastewater. Pervaporation and vapor permeation are viable methods for removing VOCs from wastewater to yield a VOC concentrate which could either be destroyed by conventional means, or be recycled for reuse.

  11. Polyvinylidene fluoride/siloxane nanofibrous membranes for long-term continuous CO2 -capture with large absorption-flux enhancement.

    PubMed

    Lin, Yi-Feng; Wang, Chi-Sen; Ko, Chia-Chieh; Chen, Chien-Hua; Chang, Kai-Shiun; Tung, Kuo-Lun; Lee, Kueir-Rarn

    2014-02-01

    In a CO2 membrane contactor system, CO2 passes through a hydrophobic porous membrane in the gas phase to contact the amine absorbent in the liquid phase. Consequently, additional CO2 gas is absorbed by amine absorbents. This study examines highly porous polyvinylidene fluoride (PVDF)/siloxane nanofibrous layers that are modified with hydrophobic fluoroalkylsilane (FAS) functional groups and successfully coated onto a macroporous Al2 O3 membrane. The performance of these materials in a membrane contactor system for CO2 absorption is also investigated. Compared with pristine PVDF nanofibrous membranes, the PVDF/siloxane nanofibrous membranes exhibit greater solvent resistance and mechanical strength, making them more suitable for use in CO2 capture by the membrane contactor. The PVDF/siloxane nanofibrous layer in highly porous FAS-modified membranes can prevent the wetting of the membrane by the amine absorbent; this extends the periods of continuous CO2 absorption and results in a high CO2 absorption flux with a minimum of 500 % enhancement over that of the uncoated membranes. This study suggests the potential use of an FAS-modified PVDF/siloxane nanofibrous membrane in a membrane contactor system for CO2 absorption. The resulting hydrophobic membrane contactor also demonstrates the potential for large-scale CO2 absorption during post-combustion processes in power plants.

  12. Thirty Stage Annular Centrifugal Contactor Thermal Profile Measurements

    SciTech Connect

    David H. Meikrantz; Troy G. Garn; Jack D. Law

    2010-02-01

    A thirty stage 5 cm annular centrifugal contactor cascade has been assembled and tested to obtain thermal profiles during both ambient and heated input conditions of operation. Thermocouples were installed on every stage as well as feed inputs and Real-time data was taken during experiments lasting from two to eight hours at total flow rates of 0.5 to 1.4 liters per minute. Ambient temperature profile results show that only a small amount of heat is generated by the mechanical energy of the contactors. Steady state temperature profiles mimic the ambient temperature of the lab but are higher toward the middle of the cascade. Heated inlet solutions gave temperature profiles with smaller temperature gradients, more driven by the temperature of the inlet solutions than ambient lab temperature. Temperature effects of solution mixing, even at rotor speeds of 4000 rpm, were not measurable.

  13. Centrifugal contactor operations for UREX process flowsheet. An update

    SciTech Connect

    Pereira, Candido; Vandegrift, George F.

    2014-08-01

    The uranium extraction (UREX) process separates uranium, technetium, and a fraction of the iodine from the other components of the irradiated fuel in nitric acid solution. In May 2012, the time, material, and footprint requirements for treatment of 260 L batches of a solution containing 130 g-U/L were evaluated for two commercial annular centrifugal contactors from CINC Industries. These calculated values were based on the expected volume and concentration of fuel arising from treatment of a single target solution vessel (TSV). The general conclusions of that report were that a CINC V-2 contactor would occupy a footprint of 3.2 m 2 (0.25 m x 15 m) if each stage required twice the nominal footprint of an individual stage, and approximately 1,131 minutes or nearly 19 hours is required to process all of the feed solution. A CINC V-5 would require approximately 9.9 m 2 (0.4 m x 25 m) of floor space but would require only 182 minutes or ~ 3 hours to process the spent target solution. Subsequent comparison with the Modular Caustic Side Solvent Extraction Unit (MCU) at Savannah River Site (SRS) in October 2013 suggested that a more compact arrangement is feasible, and the linear dimension for the CINC V-5 may be reduced to about 8 m; a comparable reduction for the CINC V-2 yields a length of 5 m. That report also described an intermediate-scale (10 cm) contactor design developed by Argonne in the early 1980s that would better align with the SHINE operations as they stood in May 2012. In this report, we revisit the previous evaluation of contactor operations after discussions with CINC Industries and analysis of the SHINE process flow diagrams for the cleanup of the TSV, which were not available at the time of the first assessment.

  14. Biological Treatment of Composition B Wastewaters. 1. Rotating Biological Contactor

    DTIC Science & Technology

    1986-09-01

    Hazardous Materials Agency ATTN: AMXTH-TE-D Aberdeen Proving Ground, MD 21010-5401 2 Commander Holston Army Ammunition Plant ATTN: SMCHO-EN Kingsport ...NA pilot-scale rotating biological contactor (RBC) was used to treat wastewaters from explosives production at Holston Army Ammunition Plant . At...waters will be similar to those from Holston Army kimunition Plant (HSAAP), presently the sole domestic source of RDX and S...... Aithoiigh more than

  15. Corrosion abatement in sulfuric acid alkylation unit horizontal contactors

    SciTech Connect

    Schutt, H.U.

    1999-03-01

    A leak to the atmosphere in the hydraulic end cone of a horizontal contactor and the realization that basic corrosion data are not available for high-throughput process conditions in alkylation units prompted a laboratory study to develop the lacking expertise. Corrosion in the horizontal contractor of an alkylation unit was mitigated successfully by saturating fresh alkylation acid with ferrous sulfate (FeSO{sub 4}).

  16. Effective Transport Properties Accounting for Electrochemical Reactions of Proton-Exchange Membrane Fuel Cell Catalyst Layers

    SciTech Connect

    Pharoah, Jon; Choi, Hae-Won; Chueh, Chih-Che; Harvey, David

    2011-07-01

    There has been a rapidly growing interest in three-dimensional micro-structural reconstruction of fuel cell electrodes so as to derive more accurate descriptors of the pertinent geometric and effective transport properties. Due to the limited accessibility of experiments based reconstruction techniques, such as dual-beam focused ion beam-scanning electro microscopy or micro X-Ray computed tomography, within sample micro-structures of the catalyst layers in polymer electrolyte membrane fuel cells (PEMFCs), a particle based numerical model is used in this study to reconstruct sample microstructure of the catalyst layers in PEMFCs. Then the reconstructed sample structure is converted into the computational grid using body-fitted/cut-cell based unstructured meshing technique. Finally, finite volume methods (FVM) are applied to calculate effective properties on computational sample domains.

  17. Hollow cathode heater development for the Space Station plasma contactor

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    1993-01-01

    A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater design. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Three heaters have been tested to date using direct current power supplies. Performance testing was conducted to determine input current and power requirements for achieving activation and ignition temperatures, single unit operational repeatability, and unit-to-unit operational repeatability. Comparisons of performance testing data at the ignition input current level for the three heaters show the unit-to-unit repeatability of input power and tube temperature near the cathode tip to be within 3.5 W and 44 degrees C, respectively. Cyclic testing was then conducted to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Two additional heaters were subsequently fabricated and have completed 3178 cycles to date in an on-going test.

  18. Integration issues of a plasma contactor Power Electronics Unit

    NASA Technical Reports Server (NTRS)

    Pinero, Luis R.; York, Kenneth W.; Bowers, Glen E.

    1995-01-01

    A hollow cathode-based plasma contactor is baselined on International Space Station Alpha (ISSA) for spacecraft charge control. The plasma contactor system consists of a hollow cathode assembly (HCA), a power electronics unit (PEU), and an expellant management unit (EMU). The plasma contactor has recently been required to operate in a cyclic mode to conserve xenon expellant and extend system life. Originally, a DC cathode heater converter was baselined for a continuous operation mode because only a few ignitions of the hollow cathode were expected. However, for cyclic operation, a DC heater supply can potentially result in hollow cathode heater component failure due to the DC electrostatic field. This can prevent the heater from attaining the proper cathode tip temperature for reliable ignition of the hollow cathode. To mitigate this problem, an AC cathode heater supply was therefore designed, fabricated, and installed into a modified PEU. The PEU was tested using resistive loads and then integrated with an engineering model hollow cathode to demonstrate stable steady-state operation. Integration issues such as the effect of line and load impedance on the output of the AC cathode heater supply and the characterization of the temperature profile of the heater under AC excitation were investigated.

  19. Integration issues of a plasma contactor Power Electronics Unit

    NASA Astrophysics Data System (ADS)

    Pinero, Luis R.; York, Kenneth W.; Bowers, Glen E.

    1995-06-01

    A hollow cathode-based plasma contactor is baselined on International Space Station Alpha (ISSA) for spacecraft charge control. The plasma contactor system consists of a hollow cathode assembly (HCA), a power electronics unit (PEU), and an expellant management unit (EMU). The plasma contactor has recently been required to operate in a cyclic mode to conserve xenon expellant and extend system life. Originally, a DC cathode heater converter was baselined for a continuous operation mode because only a few ignitions of the hollow cathode were expected. However, for cyclic operation, a DC heater supply can potentially result in hollow cathode heater component failure due to the DC electrostatic field. This can prevent the heater from attaining the proper cathode tip temperature for reliable ignition of the hollow cathode. To mitigate this problem, an AC cathode heater supply was therefore designed, fabricated, and installed into a modified PEU. The PEU was tested using resistive loads and then integrated with an engineering model hollow cathode to demonstrate stable steady-state operation. Integration issues such as the effect of line and load impedance on the output of the AC cathode heater supply and the characterization of the temperature profile of the heater under AC excitation were investigated.

  20. Functional testing of the space station plasma contactor

    NASA Astrophysics Data System (ADS)

    Patterson, Michael J.; Hamley, John A.; Sarver-Verhey, Timothy R.; Soulas, George C.

    1995-03-01

    A plasma contactor system has been baselined for the International Space Station Alpha (ISSA) to control the electrical potentials of surfaces to eliminate/mitigate damaging interactions with the space environment. The system represents a dual-use technology which is a direct outgrowth of the NASA electric propulsion program and, in particular, the technology development effort on ion thruster systems. The plasma contactor subsystems include a hollow cathode assembly, a power electronics unit, and an expellant management unit. Under a pre-flight development program these subsystems are being developed to the level of maturity appropriate for transfer to U.S. industry for final development. Development efforts for the hollow cathode assembly include design selection and refinement, validating its required lifetime, and quantifying the cathode performance and interface specifications. To date, cathode components have demonstrated over 10,000 hours lifetime, and a hollow cathode assembly has demonstrated over 3,000 ignitions. Additionally, preliminary integration testing of a hollow cathode assembly with a breadboard power electronics unit has been completed. This paper discusses test results and the development status of the plasma contactor subsystems for ISSA, and in particular, the hollow cathode assembly.

  1. Integration issues of a plasma contactor power electronics unit

    SciTech Connect

    Pinero, L.R.; York, K.W.; Bowers, G.E.

    1995-12-31

    A hollow cathode-based plasma contactor is baselined on International Space Station Alpha (ISSA) for spacecraft charge control. The plasma contactor system consists of a hollow cathode assembly (HCA), a power electronics unit (PEU), and an expellant management unit (EMU). The plasma contactor has recently been required to operate in a cyclic mode to conserve xenon expellant and extend system life. Originally, a DC cathode heater converter was baselined for a continuous operation mode because only a few ignitions of the hollow cathode were expected. However, for cyclic operation, a DC heater supply can potentially result in hollow cathode heater component failure due to the DC electrostatic field. This can prevent the heater from attaining the proper cathode tip temperature for reliable ignition of the hollow cathode. To mitigate this problem, an AC cathode heater supply was therefore designed, fabricated, and installed into a modified PEU. The PEU was tested using resistive loads and then integrated with an engineering model hollow cathode to demonstrate stable steady-state operation. Integration issues such as the effect of line and load impedance on the output of the AC cathode heater supply and the characterization of the temperature profile of the heater under AC excitation were investigated.

  2. Composite perfluorohydrocarbon membranes, their preparation and use

    DOEpatents

    Ding, Yong; Bikson, Benjamin

    2017-04-04

    Composite porous hydrophobic membranes are prepared by forming a perfluorohydrocarbon layer on the surface of a preformed porous polymeric substrate. The substrate can be formed from poly (aryl ether ketone) and a perfluorohydrocarbon layer can be chemically grafted to the surface of the substrate. The membranes can be utilized for a broad range of fluid separations, such as microfiltration, nanofiltration, ultrafiltration as membrane contactors for membrane distillation and for degassing and dewatering of fluids. The membranes can further contain a dense ultra-thin perfluorohydrocarbon layer superimposed on the porous poly (aryl ether ketone) substrate and can be utilized as membrane contactors or as gas separation. membranes for natural gas treatment and gas dehydration.

  3. A Computer Model for Teaching the Dynamic Behavior of AC Contactors

    ERIC Educational Resources Information Center

    Ruiz, J.-R. R.; Espinosa, A. G.; Romeral, L.

    2010-01-01

    Ac-powered contactors are extensively used in industry in applications such as automatic electrical devices, motor starters, and heaters. In this work, a practical session that allows students to model and simulate the dynamic behavior of ac-powered electromechanical contactors is presented. Simulation is carried out using a rigorous parametric…

  4. Plasma contactor modeling with NASCAP/LEO - Extending laboratory results to space systems

    NASA Technical Reports Server (NTRS)

    Davis, V. A.; Katz, I.; Mandell, M. J.

    1990-01-01

    In the laboratory, hollow cathode-based plasma contactors have been observed to both emit and collect ampere-level electron currents with low impedance. The laboratory behavior of hollow cathode-based plasma contactors and the limited space experience with hollow cathodes suggest that, for many applications, a hollow cathode-based plasma contactor is the ideal device to provide electrical connection with the space plasma. In order to confidently extend the laboratory experience to the low-earth-orbit environment, a series of plasma contactor computer models has been developed. Calculations show that a hollow cathode plasma contactor that collects 0.5 A in the laboratory will only collect 2.4 mA in space. The simplest way to boost the collected current is to increase the gas flow. A mole of gas is enough to collect ampere level currents for 5-1/2 hours.

  5. THE TESTING OF COMMERCIALLY AVAILABLE ENGINEERING AND PLANT SCALE ANNULAR CENTRIFUGAL CONTACTORS FOR THE PROCESSING OF SPENT NUCLEAR FUEL

    SciTech Connect

    Jack D. Law; David Meikrantz; Troy Garn; Nick Mann; Scott Herbst

    2006-10-01

    Annular centrifugal contactors are being evaluated for process scale solvent extraction operations in support of United State Advanced Fuel Cycle Initiative goals. These contactors have the potential for high stage efficiency if properly employed and optimized for the application. Commercially available centrifugal contactors are being tested at the Idaho National Laboratory to support this program. Hydraulic performance and mass transfer efficiency have been measured for portions of an advanced nuclear fuel cycle using 5-cm diameter annular centrifugal contactors. Advanced features, including low mix sleeves and clean-in-place rotors, have also been evaluated in 5-cm and 12.5-cm contactors.

  6. Extended residence time centrifugal contactor design modification and centrifugal contactor vane plate valving apparatus for extending mixing zone residence time

    DOEpatents

    Wardle, Kent E.

    2017-06-06

    The present invention provides an annular centrifugal contactor, having a housing adapted to receive a plurality of flowing liquids; a rotor on the interior of the housing; an annular mixing zone, wherein the annular mixing zone has a plurality of fluid retention reservoirs with ingress apertures near the bottom of the annular mixing zone and egress apertures located above the ingress apertures of the annular mixing zone; and an adjustable vane plate stem, wherein the stem can be raised to restrict the flow of a liquid into the rotor or lowered to increase the flow of the liquid into the rotor.

  7. Liquid–Liquid Mixing Studies in Annular Centrifugal Contactors Comparing Stationary Mixing Vane Options

    SciTech Connect

    Wardle, Kent E.

    2015-11-10

    Comparative studies of multiphase operation of annular centrifugal contactors showing the impact of housing stationary mixing vane configuration. A number of experimental results for several different mixing vane options are reported with selected measurements in a lab-scale 5 cm contactor and 12.5 cm engineering-scale unit. Fewer straight vanes give greater mixingzone hold-up compared to curved vanes. Quantitative comparison of droplet size distribution also showed a significant decrease in mean diameter for four straight vanes versus eight curved vanes. This set of measurements gives a compelling case for careful consideration of mixing vane geometry when evaluating hydraulic operation and extraction process efficiency of annular centrifugal contactors.

  8. Liquid–liquid mixing studies in annular centrifugal contactors comparing stationary mixing vane options

    SciTech Connect

    Wardle, Kent E.

    2015-09-11

    Comparative studies of multiphase operation of an annular centrifugal contactor show the impact of housing stationary mixing vane configuration. A number of experimental results for several different mixing vane options are reported for operation of a 12.5 cm engineering-scale contactor unit. Fewer straight vanes give greater mixing-zone hold-up compared to curved vanes. Quantitative comparison of droplet size distribution also showed a significant decrease in mean diameter for four straight vanes versus eight curved vanes. This set of measurements gives a compelling case for careful consideration of mixing vane geometry when evaluating hydraulic operation and extraction process efficiency of annular centrifugal contactors.

  9. Indicators for technological, environmental and economic sustainability of ozone contactors.

    PubMed

    Zhang, Jie; Tejada-Martinez, Andres E; Lei, Hongxia; Zhang, Qiong

    2016-09-15

    Various studies have attempted to improve disinfection efficiency as a way to improve the sustainability of ozone disinfection which is a critical unit process for water treatment. Baffling factor, CT10, and log-inactivation are commonly used indicators for quantifying disinfection credits. However the applicability of these indicators and the relationship between these indicators have not been investigated in depth. This study simulated flow, tracer transport, and chemical species transport in a full-scale ozone contactor operated by the City of Tampa Water Department and six other modified designs using computational fluid dynamics (CFD). Through analysis of the simulation results, we found that baffling factor and CT10 are not optimal indicators of disinfection performance. We also found that the relationship between effluent CT obtained from CT transport simulation and baffling factor depends on the location of ozone release. In addition, we analyzed the environmental and economic impacts of ozone contactor designs and upgrades and developed a composite indicator to quantify the sustainability in technological, environmental and economic dimensions.

  10. Extraction of phenol in wastewater with annular centrifugal contactors.

    PubMed

    Xu, Jin-Quan; Duan, Wu-Hua; Zhou, Xiu-Zhu; Zhou, Jia-Zhen

    2006-04-17

    Solvent extraction is an effective way to treat and recover the phenolic compounds from the high content phenolic wastewater at present. The experimental study on treating the wastewater containing phenol has been carried out with QH-1extractant (the amine mixture) and annular centrifugal contactors. The distribution ratio of phenol was 108.6 for QH-1-phenol system. The mass-transfer process of phenol for the system was mainly controlled by diffusion. When the flow ratio (aqueous/organic) was changed from 1/1 to 4/1, the rotor speed was changed from 2500 to 4000 r/min, and the total flow of two phases was changed from 20 to 70 mL/min, the mass-transfer efficiency E of the single-stage centrifugal contactor was more than 95%. When the flow ratio was changed from 4.4/1 to 4.9/1, the rotor speed was 3000 r/min, and the total flow of two phases was changed from 43.0 to 47.0 mL/min, the extraction rate rho of the three-stage cascade was more than 99%. When 15% NaOH was used for stripping of phenol in QH-1, the stripping efficiency of the three-stage cascade was also more than 99% under the experimental conditions.

  11. Solvent-resistant microporous polymide membranes

    DOEpatents

    Miller, W.K.; McCray, S.B.; Friesen, D.T.

    1998-03-10

    An asymmetric microporous membrane with exceptional solvent resistance and highly desirable permeability is disclosed. The membrane is made by a solution-casting or solution-spinning process from a copolyamic acid comprising the condensation reaction product in a solvent of at least three reactants selected from certain diamines and dianhydrides and post-treated to imidize and in some cases cross-link the copolyamic acid. The membrane is useful as an uncoated membrane for ultrafiltration, microfiltration, and membrane contactor applications, or may be used as a support for a permselective coating to form a composite membrane useful in gas separations, reverse osmosis, nanofiltration, pervaporation, or vapor permeation.

  12. Solvent-resistant microporous polymide membranes

    DOEpatents

    Miller, Warren K.; McCray, Scott B.; Friesen, Dwayne T.

    1998-01-01

    An asymmetric microporous membrane with exceptional solvent resistance and highly desirable permeability is disclosed. The membrane is made by a solution-casting or solution-spinning process from a copolyamic acid comprising the condensation reaction product in a solvent of at least three reactants selected from certain diamines and dianhydrides and post-treated to imidize and in some cases cross-link the copolyamic acid. The membrane is useful as an uncoated membrane for ultrafiltration, microfiltration, and membrane contactor applications, or may be used as a support for a permselective coating to form a composite membrane useful in gas separations, reverse osmosis, nanofiltration, pervaporation, or vapor permeation.

  13. Identification And Characterization Of The Solids Found In Extraction Contactor SEP-401 In June 2012

    SciTech Connect

    Fondeur, F. F.; Fink, S. D.

    2012-12-10

    The Modular Caustic-Side Solvent Extraction Unit (MCU) recently conducted an outage that included maintenance on the centrifugal contactors. Operations personnel observed solids or deposits in two contactors and attempted to collect samples for analyses by Savannah River National Laboratory (SRNL). The residues found in Extraction Contactor SEP-401 are a mixture of amorphous silica, aluminosilicate, titanium, and debris from low alloy steel. The solids contain low concentrations of plutonium and strontium. These isotopes are associated with the titanium that came from the monosodium titanate (MST) added in the Actinide Removal Process (ARP) most likely as leached Ti from the MST that precipitated subsequently in MCU. An attempt was also made to obtain samples from the contents of Wash Contactor SEP-702. However, sampling provide ineffective.

  14. OZONE CONTACTOR FLOW VISUALIZATION AND CHARACTERIZATION USING 3-DIMENSIONAL LASER INDUCED FLUORESCENCE

    EPA Science Inventory

    Hydrodynamics of ozone contactors have a crucial impact on efficient inactivation of pathogens such as Cryptosporidium as well as control of disinfection byproducts such as bromate. Improper mixing behaviors including short-circuiting, internal recirculation and presence...

  15. OZONE CONTACTOR FLOW VISUALIZATION AND CHARACTERIZATION USING 3-DIMENSIONAL LASER INDUCED FLUORESCENCE

    EPA Science Inventory

    Hydrodynamics of ozone contactors have a crucial impact on efficient inactivation of pathogens such as Cryptosporidium as well as control of disinfection byproducts such as bromate. Improper mixing behaviors including short-circuiting, internal recirculation and presence...

  16. Rotating arc cutoff with a Fluarc switch or a Rollarc contactor in SF6

    NASA Astrophysics Data System (ADS)

    Duplay, C.

    1983-05-01

    The principles of rotating arc cutoff are reviewed, and applications to circuit breakers and contactors are indicated. The Rollarc (trademark) contactor offers high cutoff power (10 KA at 7.2 KV) and an extremely low level of overvoltage. The Fluorarc (trademark) circuit breaker is similar to the Rollarc, using a magnetic coil to shift the arc, but uses knife switches which are separated from the coil/arc assembly. Fluorarc is sealed for life, and requires no maintenance.

  17. Status of Hollow Cathode Heater Development for the Space Station Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    1994-01-01

    A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Heater tests included testing of the heater unit alone and plasma contactor and ion thruster testing. To date, eight heaters have been or are being processed through heater unit testing, two through plasma contactor testing and three through ion thruster testing, all using direct current power supplies. Comparisons of data from heater unit performance tests before cyclic testing, plasma contactor tests, and ion thruster tests at the ignition input current level show the average deviation of input power and tube temperature near the cathode tip to be +/-0.9 W and +/- 21 C, respectively. Heater unit testing included cyclic testing to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Four additional heaters successfully completed 6300, 6300, 700, and 700 cycles. Heater unit testing is currently ongoing for three heaters which have to date accumulated greater than 7250, greater than 5500, and greater than 5500 cycles, respectively.

  18. An investigation of conducted and radiated emissions from a hollow-cathode plasma contactor

    NASA Technical Reports Server (NTRS)

    Buchholtz, Brett W.; Wilbur, Paul J.

    1993-01-01

    An investigation conducted on the electrical interference induced by the operation of a hollow-cathode plasma contractor in a ground-based facility is described. The types of electrical interference, or noise, which are important to Space Station Freedom designers are classified as either conducted or radiated emissions. The procedures required to perform conducted and radiated emission measurements on a plasma contactor are examined. The experimental data obtained are typically examined in the frequency domain (i.e. amplitudes of the noise fluctuations versus frequency). Results presented indicate the conducted emissions, which are the current fluctuations from the contactor into the space station wiring, are affected by operating parameters such as expellant flow rate and discharge current. The radiated emissions, which are the electromagnetic waves induced and emitted by the contactor, appear to be influenced by the contactor emission current. Other experimental results suggest possible sources which are responsible for the observed noise. For example, the influence of the plasma environment downstream from the contactor on noise emission levels is described. In addition, a brief discussion is given on the correlation between conducted and radiated emissions and the mechanisms through which both are influenced by the plasma downstream of the contactor.

  19. Cost/performance comparison between pulse columns and centrifugal contactors designed to process Clinch River Breeder Reactor fuel

    SciTech Connect

    Ciucci, J.A. Jr.

    1983-12-01

    A comparison between pulse columns and centrifugal contactors was made to determine which type of equipment was more advantageous for use in the primary decontamination cycle of a remotely operated fuel reprocessing plant. Clinch River Breeder Reactor (CRBR) fuel was chosen as the fuel to be processed in the proposed 1 metric tonne/day reprocessing facility. The pulse columns and centrifugal contactors were compared on a performance and total cost basis. From this comparison, either the pulse columns or the centrifugal contactors will be recommended for use in a fuel reprocessing plant built to reprocess CRBR fuel. The reliability, solvent exposure to radiation, required time to reach steady state, and the total costs were the primary areas of concern for the comparison. The pulse column units were determined to be more reliable than the centrifugal contactors. When a centrifugal contactor motor fails, it can be remotely changed in less than one eight hour shift. Pulse columns expose the solvent to approximately five times as much radiation dose as the centrifugal contactor units; however, the proposed solvent recovery system adequately cleans the solvent for either case. The time required for pulse columns to reach steady state is many times longer than the time required for centrifugal contactors to reach steady state. The cost comparison between the two types of contacting equipment resulted in centrifugal contactors costing 85% of the total cost of pulse columns when the contactors were stacked on three levels in the module. If the centrifugal contactors were all positioned on the top level of a module with the unoccupied volume in the module occupied by other equipment, the centrifugal contactors cost is 66% of the total cost of pulse columns. Based on these results, centrifugal contactors are recommended for use in a remotely operated reprocessing plant built to reprocess CRBR fuel.

  20. Discharge ignition behavior of the Space Station plasma contactor

    NASA Technical Reports Server (NTRS)

    Sarver-Verhey, Timothy R.; Hamley, John A.

    1995-01-01

    Ignition testing of hollow cathode assemblies being developed for the Space Station plasma contactor system has been initiated to validate reliable multiple restart capability. An ignition approach was implemented that was derived from an earlier arcjet program that successfully demonstrated over 11,600 ignitions. For this, a test profile was developed to allow accelerated cyclic testing at expected operating conditions. To date, one hollow cathode assembly has been used to demonstrate multiple ignitions. A prototype hollow cathode assembly has achieved 3,615 successful ignitions at a nominal anode voltage of 18.0 V. During the ignition testing several parameters were investigated, of which the heater power and pre-heat time were the only parameters found to significantly impact ignition rate.

  1. Simulation of citric acid production by rotating disk contactor.

    PubMed

    Sakurai, A; Imai, H; Takenaka, Y; Sakakibara, M

    1997-12-20

    A simple model was presented to describe the time courses of citric acid production by a rotating disc contactor (RDC) using Aspergillus niger. The model is expressed by Monod-type cell growth, Luedeking-Piret-type citric acid production rate equations, and the diffusion equation for oxygen in the biofilm. The model contains five parameters which were determined by the nonlinear least squares method by fitting the numerical solution to the experimental data. In solving the equations, the cell density of the biofilm was estimated from the value of cellular mass per unit of biofilm area using an empirical equation. The experimental time courses in citric acid production period were well simulated with this model. The relation between the specific biofilm surface area and the rate of citric acid production was also explained by the simulation using the average values of five parameters of twelve runs. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 56: 689-696, 1997.

  2. Performance analysis of rotating disc contactor (RDC) column

    NASA Astrophysics Data System (ADS)

    Aiffah, Wan Nurul; Aisyah, Siti; Fashihah, Nor; Anuar, Khairil

    2014-06-01

    Liquid-liquid extraction is one of the most important separation processes. Different kinds of liquid-liquid extrator such as Rotating Disc Contactor (RDC) Column being used in industries. The study of liquid-liquid extraction in an RDC column has be come a very important subject to be discussed not just amongst chemical engineers but mathematicans as well. In this study, the performance of small diameter column RDC using the chemical system involving cumene/isobutryric asid/water are analyzed by the method of design of the experiments (DOE). DOE are applied to estimated the effect of four independent variable; protor speed, flow rate, concentration of continuous inlet and dispersed inlet and their interaction factor to detemine the most significant factor that effect the concentration of continuous and dispersed outlet as output parameters.

  3. Experimental and modeling study on removal of pharmaceutically active compounds in rotating biological contactors.

    PubMed

    Vasiliadou, I A; Molina, R; Martínez, F; Melero, J A

    2014-06-15

    The aim of this work was to study the biological removal of pharmaceutical compounds in rotating biological contactors (RBCs) under continuous operation. A two-stage RBC was used, providing a total surface area of 1.41 m(2). Four pharmaceuticals of different therapeutic classes; caffeine, sulfamethoxazole, ranitidine and carbamazepine, were studied. Six experimental scenarios were applied to the RBC-system by varying substrates' loadings (12-54 gCOD/d), volumetric flow rate (2-5L/d), and pharmaceuticals' concentration (20-50 μg/L). The different conditions resulted to different solid retention times (SRT: 7-21 d) in each scenario. The increase of SRT due to variations of the operating conditions seemed to have a positive effect on pharmaceuticals' removal. Likewise, a negative correlation was observed between substrates' loading and pharmaceuticals' removal. An increase of initial pharmaceuticals' concentration resulted to decrease of SRT and pharmaceuticals' removal, suggesting a toxic effect to the biofilm. The maximum removals achieved were greater than 85% for all pharmaceuticals. Finally, a mathematical model which includes biofilm growth, substrates' utilization and pharmaceuticals' elimination was developed. The model predicts the contribution of sorption and biodegradation on pharmaceuticals' elimination taking into account the diffusion of pharmaceuticals inside biofilm.

  4. Selective aqueous extraction of organics coupled with trapping by membrane separation

    SciTech Connect

    van Eikeren, P.; Brose, D.J.; Ray, R.J.

    1991-08-20

    This patent describes improvement in an organic/aqueous extraction process for the extraction of an organic solute from an organic solvent or solvent mixture with an aqueous-based extractant. The improvement comprises continuously recycling the aqueous-based extractant through a membrane separation process that selectively removes the organic solute from the aqueous-based extractant, the membrane separation process being selected from at least one of reverse osmosis, nanofiltration, ultrafiltration, membrane distillation, pervaporation, membrane contactor and supported-liquid membrane.

  5. ISS And Space Environment Interactions Without Operating Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Carruth, M. R., Jr.; Ferguson, Dale; Suggs,Rob; McCollum, Matt

    2001-01-01

    The International Space Station (ISS) will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur. The details of interaction effects on spacecraft have not been addressed until driven by design. This was true for ISS. If the structure is allowed to float highly negative impinging ions can sputter exposed conductors which can degrade the primary surface and also generate contamination due to the sputtered material. Arcing has been known to occur on solar arrays that float negative of the ambient plasma. This can also generate electromagnetic interference and voltage transients. Much of the ISS structure and pressure module surfaces exposed to space is anodized aluminum. The anodization

  6. ISS And Space Environment Interactions Without Operating Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Carruth, M. R., Jr.; Ferguson, Dale; Suggs,Rob; McCollum, Matt

    2001-01-01

    The International Space Station (ISS) will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur. The details of interaction effects on spacecraft have not been addressed until driven by design. This was true for ISS. If the structure is allowed to float highly negative impinging ions can sputter exposed conductors which can degrade the primary surface and also generate contamination due to the sputtered material. Arcing has been known to occur on solar arrays that float negative of the ambient plasma. This can also generate electromagnetic interference and voltage transients. Much of the ISS structure and pressure module surfaces exposed to space is anodized aluminum. The anodization

  7. Evaluating hydraulic and disinfection efficiencies of a full-scale ozone contactor using a RANS-based modeling framework.

    PubMed

    Zhang, Jie; Tejada-Martínez, Andrés E; Zhang, Qiong; Lei, Hongxia

    2014-04-01

    The capability of predicting hydraulic and disinfection efficiencies of ozone disinfection contactors is essential for evaluating existing contactors and improving future designs. Previous attempts based on ideal and non-ideal models for the hydraulics and simplified mechanisms for chemical reaction modeling have resulted in low accuracy and are restricted to contactors with simple geometries. This manuscript develops a modeling framework for the ozonation process by combining computational fluid dynamics (CFD) with a kinetics-based reaction modeling for the first time. This computational framework has been applied to the full-scale ozone contactor operated by the City of Tampa Water Department. Flow fields, residence time distribution, ozone concentration distribution, and concentration-contact time (CT) distribution within the contactor have been predicted via the computational framework. The predictions of ozone and bromate concentrations at sample points agree well with physical experimental data measured in the contactor. The predicted CT values at the contactor outlet demonstrate that the disinfection performance of the ozone contactor operated by the City of Tampa Water Department is sufficient to meet regulation requirements. The impact of seasonal flow rate change on disinfection performance is found to be significant and deserves attention during the management and operation of a water treatment plant.

  8. Development of a Power Electronics Unit for the Space Station Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Hamley, John A.; Hill, Gerald M.; Patterson, Michael J.; Saggio, Joseph, Jr.; Terdan, Fred; Mansell, Justin D.

    1994-01-01

    A hollow cathode plasma contactor has been baselined as a charge control device for the Space Station (SS) to prevent deleterious interactions of coated structural components with the ambient plasma. NASA LeRC Work Package 4 initiated the development of a plasma contactor system comprised of a Power Electronics Unit (PEU), an Expellant Management Unit (EMU), a command and data interface, and a Plasma Contactor Unit (PCU). A breadboard PEU was designed and fabricated. The breadboard PEU contains a cathode heater and discharge power supply, which were required to operate the PCU, a control and auxiliary power converter, an EMU interface, a command and telemetry interface, and a controller. The cathode heater and discharge supplies utilized a push-pull topology with a switching frequency of 20 kHz and pulse-width-modulated (PWM) control. A pulse ignition circuit derived from that used in arcjet power processors was incorporated in the discharge supply for discharge ignition. An 8088 based microcontroller was utilized in the breadboard model to provide a flexible platform for controller development with a simple command/data interface incorporating a direct connection to SS Mulitplexer/Demultiplexer (MDM) analog and digital I/O cards. Incorporating this in the flight model would eliminate the hardware and software overhead associated with a 1553 serial interface. The PEU autonomously operated the plasma contactor based on command inputs and was successfully integrated with a prototype plasma contactor unit demonstrating reliable ignition of the discharge and steady-state operation.

  9. Hydraulic Performance and Mass Transfer Efficiency of Engineering Scale Centrifugal Contactors

    SciTech Connect

    David Meikrantz; Troy Garn; Nick Mann; Jack Law; Terry Todd

    2007-09-01

    Annular centrifugal contactors (ACCs) are being evaluated for process-scale solvent extraction operations in support of Advanced Fuel Cycle Initiative (AFCI) separations goals. Process-scale annular centrifugal contactors have the potential for high stage efficiency if properly employed and optimized for the application. Hydraulic performance issues related to flow instability and classical flooding are likely unimportant, especially for units with high throughputs. However, annular mixing increases rapidly with increasing rotor diameter while maintaining a fixed g force at the rotor wall. In addition, for engineering/process-scale contactors, elevated rotor speeds and/or throughput rates, can lead to organic phase foaming at the rotor discharge collector area. Foam buildup in the upper rotor head area can aspirate additional vapor from the contactor housing resulting in a complete loss of separation equilibrium. Variable speed drives are thus desirable to optimize and balance the operating parameters to help ensure acceptable performance. Proper venting of larger contactors is required to balance pressures across individual stages and prevent vapor lock due to foam aspiration.

  10. Membrane Technologies in Wine Industry: An Overview.

    PubMed

    El Rayess, Youssef; Mietton-Peuchot, Martine

    2016-09-09

    Membrane processes are increasingly reported for various applications in wine industry such as microfiltration, electrodialysis, and reverse osmosis, but also emerging processes as bipolar electrodialysis and membrane contactor. Membrane-based processes are playing a critical role in the field of separation/purification, clarification, stabilization, concentration, and de-alcoholization of wine products. They begin to be an integral part of the winemaking process. This review will provide an overview of recent developments, applications, and published literature in membrane technologies applied in wine industry.

  11. Mesoporous fluorocarbon-modified silica aerogel membranes enabling long-term continuous CO2 capture with large absorption flux enhancements.

    PubMed

    Lin, Yi-Feng; Chen, Chien-Hua; Tung, Kuo-Lun; Wei, Te-Yu; Lu, Shih-Yuan; Chang, Kai-Shiun

    2013-03-01

    The use of a membrane contactor combined with a hydrophobic porous membrane and an amine absorbent has attracted considerable attention for the capture of CO2 because of its extensive use, low operational costs, and low energy consumption. The hydrophobic porous membrane interface prevents the passage of the amine absorbent but allows the penetration of CO2 molecules that are captured by the amine absorbent. Herein, highly porous SiO2 aerogels modified with hydrophobic fluorocarbon functional groups (CF3 ) were successfully coated onto a macroporous Al2 O3 membrane; their performance in a membrane contactor for CO2 absorption is discussed. The SiO2 aerogel membrane modified with CF3 functional groups exhibits the highest CO2 absorption flux and can be continuously operated for CO2 absorption for extended periods of time. This study suggests that a SiO2 aerogel membrane modified with CF3 functional groups could potentially be used in a membrane contactor for CO2 absorption. Also, the resulting hydrophobic SiO2 aerogel membrane contactor is a promising technology for large-scale CO2 absorption during the post-combustion process in power plants. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Advanced electric propulsion and space plasma contactor research

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1986-01-01

    A series of experiments performed on an 8 cm dia. ring cusp magnetic field ion thruster are described. The results show the effects of anode and cathode position and size, ring cusp axial location and discharge chamber length on plasma ion energy cost and extracted ion fraction. Thruster performance is shown to be improved substantially when optimum values of these parameters are used. Investigations into the basic plasma phenomena associated with the process of plasma contacting are described. The results show the process of electron collection from a background plasma to a hollow cathode plasma contactor exhibits a higher impedance than the process of electron emission from the hollow cathode. The importance of having cold ions present to facilitate the plasma contacting process is shown. Results of experiments into the behavior of hollow cathodes operating at high interelectrode pressures (up to approx. 100 Torr) on nitrogen and ammonia are presented. They suggest that diffuse emission from the insert of a hollow cathode can be sustained at high interelectrode pressures if the cathode is made of non-conducting material and the cathode internal pressure is reduced by evacuating the cathode interior. A theoretical model of discharge chamber operation developed for inert gas thrusters is extended so it can be used to evaluste the performance of mercury ion thrusters. Predictions of the model are compared to experimental results obtained on two 30 cm dia. thrusters.

  13. Groundwater treatment in a field pilot methanotrophic rotating biological contactor

    SciTech Connect

    Belcher, D.M.; Vira, A.; Dooley, M.A.; Johnson, J.C.

    1995-12-31

    A pilot-scale rotating biological contactor (RBC) was operated under field conditions for approximately 1 month to remove chlorinated and nonchlorinated organic compounds from groundwater. Methanotrophic conditions were successfully established and maintained in the RBC during the field program. Results of the pilot program indicated that low concentrations of cis-1,2-dichloroethene (cis-DCE) and vinyl chloride could be treated to below the maximum contaminant levels (MCLs) of 70 ad 2 {micro}g/L, respectively. Maximum removal rates for cis-DCE and vinyl chloride measured during the pilot study were 2.14 {micro}g cis-DCE/ft{sup 2} disc media-minute (952 {micro}g cis-DCE/mg volatile solids [VS]-day) and 0.3 {micro}g vinyl chloride/ft{sup 2}-minute (143 {micro}g vinyl chloride/mg VS-day), respectively. Chlorinated ethene removal efficiencies decreased after the first 2 weeks of operation. Low concentrations of toluene, ethylbenzene, and total xylenes (TEX) were effectively removed from groundwater throughout the course of the pilot study. The maximum observed TEX removal rate was 3.0 {micro}g TEX/ft{sup 2}-minute.

  14. Life Cycle Tests on a Hollow Cathode Based Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Vaughn, Jason A.; Schneider, Todd A.; Munafo, Paul (Technical Monitor)

    2001-01-01

    The propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta II unmanned expendable booster with a mission duration of 12 days. A 5-km conductive tether is attached to the Delta II second stage and collects current from the low Earth orbit (LEO) plasma, and a Hollow Cathode Plasma Contactor (HCPC) emits the collected electrons from the Delta II, completing the electrical circuit to the ambient plasma. The HCPC for the ProSEDS mission have made it necessary to turn off the HCPC once a minute throughout the entire mission. Because of the unusual operating requirements by the ProSEDS mission, an engineering development unit of the HCPC was built to demonstrate the HCPC design would start reliably for the life of the ProSEDS mission. During the life test the engineering unit cycled for over 10,000 on/off cycles without missing a single start, and during that same test the HCPC unit demonstrated the capability to emit 0 to 5 A electron emission current. The performance of the HCPC unit during this life test will be discussed.

  15. Life Cycle Tests on a Hollow Cathode Based Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Vaughn, Jason A.; Schneider, Todd A.; Munafo, Paul (Technical Monitor)

    2001-01-01

    The propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta II unmanned expendable booster with a mission duration of 12 days. A 5-km conductive tether is attached to the Delta II second stage and collects current from the low Earth orbit (LEO) plasma, and a Hollow Cathode Plasma Contactor (HCPC) emits the collected electrons from the Delta II, completing the electrical circuit to the ambient plasma. The HCPC for the ProSEDS mission have made it necessary to turn off the HCPC once a minute throughout the entire mission. Because of the unusual operating requirements by the ProSEDS mission, an engineering development unit of the HCPC was built to demonstrate the HCPC design would start reliably for the life of the ProSEDS mission. During the life test the engineering unit cycled for over 10,000 on/off cycles without missing a single start, and during that same test the HCPC unit demonstrated the capability to emit 0 to 5 A electron emission current. The performance of the HCPC unit during this life test will be discussed.

  16. Liquid–liquid mixing studies in annular centrifugal contactors comparing stationary mixing vane options

    DOE PAGES

    Wardle, Kent E.

    2015-09-11

    Comparative studies of multiphase operation of an annular centrifugal contactor show the impact of housing stationary mixing vane configuration. A number of experimental results for several different mixing vane options are reported for operation of a 12.5 cm engineering-scale contactor unit. Fewer straight vanes give greater mixing-zone hold-up compared to curved vanes. Quantitative comparison of droplet size distribution also showed a significant decrease in mean diameter for four straight vanes versus eight curved vanes. This set of measurements gives a compelling case for careful consideration of mixing vane geometry when evaluating hydraulic operation and extraction process efficiency of annular centrifugalmore » contactors.« less

  17. Extended test of a xenon hollow cathode for a space plasma contactor

    NASA Technical Reports Server (NTRS)

    Sarver-Verhey, Timothy R.

    1994-01-01

    Implementation of a hollow cathode plasma contactor for charge control on the Space Station has required validation of long-life hollow cathodes. A test series of hollow cathodes and hollow cathode plasma contactors was initiated as part of the plasma contactor development program. An on-going wear-test of a hollow cathode has demonstrated cathode operation in excess of 4700 hours with small changes in operating parameters. The discharge experienced 4 shutdowns during the test, all of which were due to test facility failures or expellant replenishment. In all cases, the cathode was reignited at approximately 42 volts and resumed typical operation. This test represents the longest demonstrated stable operation of a high current (greater than 1A) xenon hollow cathode reported to date.

  18. Continuing life test of a xenon hollow cathode for a space plasma contactor

    NASA Technical Reports Server (NTRS)

    Sarver-Verhey, Timothy R.

    1994-01-01

    Implementation of a hollow cathode plasma contactor for charge control on the Space Station has required validation of long-life hollow cathodes. A test series of hollow cathodes and hollow cathode plasma contactors was initiated as part of the plasma contactor development program. An on-going wear-test of a hollow cathode has demonstrated cathode operation in excess of 10,000 hours with small changes in operating parameters. The discharge has experienced 10 shutdowns during the test, all of which were due to test facility failures or expellant replenishment. In all cases, the cathode was re-ignited at approximately 42 volts and resumed typical operation. This test represents the longest demonstrated stable operation of a high current (greater than 1 A) xenon hollow cathode reported to date.

  19. Apparatus for supporting contactors used in extracting nuclear materials from liquids

    DOEpatents

    Leonard, Ralph A.; Frank, Robert C.

    1991-01-01

    Apparatus is provided for supporting one or more contactor stages used to remove radioactive materials from aqueous solutions. The contactor stages include a housing having an internal rotor, a motor secured to the top of the housing for rotating the rotor, and a drain in the bottom of the housing. The support apparatus includes two or more vertical members each secured to a ground support that is horizontal and perpendicular to the frame member, and a horizontally disposed frame member. The frame member may be any suitable shape, but is preferably a rectangular tube having substantially flat, spaced top and bottom surfaces separated by substantially vertical side surfaces. The top and bottom surfaces each have an opening through which the contactor housing is secured so that the motor is above the frame and the drain is below the frame during use.

  20. Reliability Optimization Design for Contact Springs of AC Contactors Based on Adaptive Genetic Algorithm

    NASA Astrophysics Data System (ADS)

    Zhao, Sheng; Su, Xiuping; Wu, Ziran; Xu, Chengwen

    The paper illustrates the procedure of reliability optimization modeling for contact springs of AC contactors under nonlinear multi-constraint conditions. The adaptive genetic algorithm (AGA) is utilized to perform reliability optimization on the contact spring parameters of a type of AC contactor. A method that changes crossover and mutation rates at different times in the AGA can effectively avoid premature convergence, and experimental tests are performed after optimization. The experimental result shows that the mass of each optimized spring is reduced by 16.2%, while the reliability increases to 99.9% from 94.5%. The experimental result verifies the correctness and feasibility of this reliability optimization designing method.

  1. Design, performance, and evaluation of a direct-current contactor for space nuclear electrical systems

    NASA Technical Reports Server (NTRS)

    Mueller, L. A.; Medwid, D. W.; Koutnik, E. A.; Powell, A. H.

    1972-01-01

    A direct-current contactor for use in large space power systems was designed, built, and tested. It was developed to be operational in an environment of 540 C and at a pressure of 0.0001 N/sq m or lower. The contactor is rated to pass 10 A continuously and to interrupt a 20-A current at 10,000 V. It was tested to determine the corona threshold level and the leakage current at different temperatures. Also, it was tested for its closing and interruption ability.

  2. Real-time UV-visible spectroscopy analysis of purple membrane-polyacrylamide film formation taking into account Fano line shapes and scattering.

    PubMed

    Gomariz, María; Blaya, Salvador; Acebal, Pablo; Carretero, Luis

    2014-01-01

    We theoretically and experimentally analyze the formation of thick Purple Membrane (PM) polyacrylamide (PA) films by means of optical spectroscopy by considering the absorption of bacteriorhodopsin and scattering. We have applied semiclassical quantum mechanical techniques for the calculation of absorption spectra by taking into account the Fano effects on the ground state of bacteriorhodopsin. A model of the formation of PM-polyacrylamide films has been proposed based on the growth of polymeric chains around purple membrane. Experimentally, the temporal evolution of the polymerization process of acrylamide has been studied as function of the pH solution, obtaining a good correspondence to the proposed model. Thus, due to the formation of intermediate bacteriorhodopsin-doped nanogel, by controlling the polymerization process, an alternative methodology for the synthesis of bacteriorhodopsin-doped nanogels can be provided.

  3. Real-Time UV-Visible Spectroscopy Analysis of Purple Membrane-Polyacrylamide Film Formation Taking into Account Fano Line Shapes and Scattering

    PubMed Central

    Gomariz, María; Blaya, Salvador; Acebal, Pablo; Carretero, Luis

    2014-01-01

    We theoretically and experimentally analyze the formation of thick Purple Membrane (PM) polyacrylamide (PA) films by means of optical spectroscopy by considering the absorption of bacteriorhodopsin and scattering. We have applied semiclassical quantum mechanical techniques for the calculation of absorption spectra by taking into account the Fano effects on the ground state of bacteriorhodopsin. A model of the formation of PM-polyacrylamide films has been proposed based on the growth of polymeric chains around purple membrane. Experimentally, the temporal evolution of the polymerization process of acrylamide has been studied as function of the pH solution, obtaining a good correspondence to the proposed model. Thus, due to the formation of intermediate bacteriorhodopsin-doped nanogel, by controlling the polymerization process, an alternative methodology for the synthesis of bacteriorhodopsin-doped nanogels can be provided. PMID:25329473

  4. High-Resolution Coarse-Grained Model of Hydrated Anion-Exchange Membranes that Accounts for Hydrophobic and Ionic Interactions through Short-Ranged Potentials.

    PubMed

    Lu, Jibao; Jacobson, Liam C; Perez Sirkin, Yamila A; Molinero, Valeria

    2017-01-10

    Molecular simulations provide a versatile tool to study the structure, anion conductivity, and stability of anion-exchange membrane (AEM) materials and can provide a fundamental understanding of the relation between structure and property of membranes that is key for their use in fuel cells and other applications. The quest for large spatial and temporal scales required to model the multiscale structure and transport processes in the polymer electrolyte membranes, however, cannot be met with fully atomistic models, and the available coarse-grained (CG) models suffer from several challenges associated with their low-resolution. Here, we develop a high-resolution CG force field for hydrated polyphenylene oxide/trimethylamine chloride (PPO/TMACl) membranes compatible with the mW water model using a hierarchical parametrization approach based on Uncertainty Quantification and reference atomistic simulations modeled with the Generalized Amber Force Field (GAFF) and TIP4P/2005 water. The parametrization weighs multiple properties, including coordination numbers, radial distribution functions (RDFs), self-diffusion coefficients of water and ions, relative vapor pressure of water in the solution, hydration enthalpy of the tetramethylammonium chloride (TMACl) salt, and cohesive energy of its aqueous solutions. We analyze the interdependence between properties and address how to compromise between the accuracies of the properties to achieve an overall best representability. Our optimized CG model FFcomp quantitatively reproduces the diffusivities and RDFs of the reference atomistic model and qualitatively reproduces the experimental relative vapor pressure of water in solutions of tetramethylammonium chloride. These properties are of utmost relevance for the design and operation of fuel cell membranes. To our knowledge, this is the first CG model that includes explicitly each water and ion and accounts for hydrophobic, ionic, and intramolecular interactions explicitly

  5. Single Stage Contactor Testing Of The Next Generation Solvent Blend

    SciTech Connect

    Herman, D. T.; Peters, T. B.; Duignan, M. R.; Williams, M. R.; Poirier, M. R.; Brass, E. A.; Garrison, A. G.; Ketusky, E. T.

    2014-01-06

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

  6. Surface-Roughness-Based Virtual Textiles: Evaluation Using a Multi-Contactor Display.

    PubMed

    Philpott, Matthew; Summers, Ian R

    2015-01-01

    Virtual textiles, generated in response to exploratory movements, are presented to the fingertip via a 24-contactor vibrotactile array. Software models are based on surface-roughness profiles from real textiles. Results suggest that distinguishable "textile-like" surfaces are produced, but these lack the necessary accuracy for reliable matching to real textiles.

  7. An experimental investigation of hollow cathode-based plasma contactors. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Williams, John D.

    1991-01-01

    Experimental results are presented which describe operation of the plasma environment associated with a hollow cathod-based plasma contactor collecting electrons from or emitting them to an ambient, low density Maxwellian plasma. A one-dimensional, phenomenological model of the near-field electron collection process, which was formulated from experimental observations, is presented. It considers three regions, namely, a plasma cloud adjacent to the contactor, an ambient plasma from which electrons are collected, and a double layer region that develops between the contactor plasma cloud and the ambient plasma regions. Results of the electron emission experiments are also presented. An important observation is made using a retarding potential analyzer (RPA) which shows that high energy ions generally stream from a contactor along with the electrons being emitted. A mechanism for this phenomenon is presented and it involves a high rate of ionization induced between electrons and atoms flowing together from the hollow cathode orifice. This can result in the development of a region of high positive potential. Langmuir and RPA probe data suggest that both electrons and ions expand spherically from this hill region. In addition to experimental observations, a one-dimensional model which describes the electron emission process and predicts the phenomena just mentioned is presented and shown to agree qualitatively with these observations.

  8. Using 3D LIF to Investigate and Improve Performance of a Multichamber Ozone Contactor

    EPA Science Inventory

    Three-dimensional laser-induced fluorescence (3DLIF) was applied to visualize and quantitatively analyze hydrodynamics and mixing in a multi-chamber ozone contactor, the most widely used design for water disinfection. The results suggested that the mixing was characterized by ext...

  9. Validation of a simple method for predicting the disinfection performance in a flow-through contactor.

    PubMed

    Pfeiffer, Valentin; Barbeau, Benoit

    2014-02-01

    Despite its shortcomings, the T10 method introduced by the United States Environmental Protection Agency (USEPA) in 1989 is currently the method most frequently used in North America to calculate disinfection performance. Other methods (e.g., the Integrated Disinfection Design Framework, IDDF) have been advanced as replacements, and more recently, the USEPA suggested the Extended T10 and Extended CSTR (Continuous Stirred-Tank Reactor) methods to improve the inactivation calculations within ozone contactors. To develop a method that fully considers the hydraulic behavior of the contactor, two models (Plug Flow with Dispersion and N-CSTR) were successfully fitted with five tracer tests results derived from four Water Treatment Plants and a pilot-scale contactor. A new method based on the N-CSTR model was defined as the Partially Segregated (Pseg) method. The predictions from all the methods mentioned were compared under conditions of poor and good hydraulic performance, low and high disinfectant decay, and different levels of inactivation. These methods were also compared with experimental results from a chlorine pilot-scale contactor used for Escherichia coli inactivation. The T10 and Extended T10 methods led to large over- and under-estimations. The Segregated Flow Analysis (used in the IDDF) also considerably overestimated the inactivation under high disinfectant decay. Only the Extended CSTR and Pseg methods produced realistic and conservative predictions in all cases. Finally, a simple implementation procedure of the Pseg method was suggested for calculation of disinfection performance.

  10. Theory of plasma contactors in ground-based experiments and low Earth orbit

    NASA Technical Reports Server (NTRS)

    Gerver, M. J.; Hastings, Daniel E.; Oberhardt, M. R.

    1990-01-01

    Previous theoretical work on plasma contactors as current collectors has fallen into two categories: collisionless double layer theory (describing space charge limited contactor clouds) and collisional quasineutral theory. Ground based experiments at low current are well explained by double layer theory, but this theory does not scale well to power generation by electrodynamic tethers in space, since very high anode potentials are needed to draw a substantial ambient electron current across the magnetic field in the absence of collisions (or effective collisions due to turbulence). Isotropic quasineutral models of contactor clouds, extending over a region where the effective collision frequency upsilon sub e exceeds the electron cyclotron frequency omega sub ce, have low anode potentials, but would collect very little ambient electron current, much less than the emitted ion current. A new model is presented, for an anisotropic contactor cloud oriented along the magnetic field, with upsilon sub e less than omega sub ce. The electron motion along the magnetic field is nearly collisionless, forming double layers in that direction, while across the magnetic field the electrons diffuse collisionally and the potential profile is determined by quasineutrality. Using a simplified expression for upsilon sub e due to ion acoustic turbulence, an analytic solution has been found for this model, which should be applicable to current collection in space. The anode potential is low and the collected ambient electron current can be several times the emitted ion current.

  11. Rotating biological contactors: Wastewater treatment. (Latest citations from the NTIS bibliographic database). Published Search

    SciTech Connect

    1995-10-01

    The bibliography contains citations concerning wastewater treatment using rotating biological contactors (RBC). Citations focus on reaction kinetics, operational modeling, and removal efficiencies. Biological oxygen demand (BOD) and nitrogen removal are discussed. Citations examine performance of RBCs in industrial and municipal applications. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  12. Evaluation of high-efficiency gas liquid contactors for natural gas processing

    SciTech Connect

    Palla, N.; Lee, A.L.

    1995-06-01

    The objectives of this program are to develop and evaluate advanced processing technologies that can reduce the cost of upgrading sub quality natural gas to pipeline standards. The successful application of cost-effective, new technologies will facilitate the production of sub quality natural gas that otherwise would be too expensive to produce. The overall program is focused on the following activities: evaluation of the potential of structured packing for the removal of acid gases from natural gases, and expansion of the currently available database of the fluid dynamics of rotating gas liquid contactors. The natural gas sweetening, structured packing field tests are scheduled to be conducted in calendar year 1995. Design, procurement and construction of the field test unit. Expansion of the available data base on the hydraulic characteristics of a rotating gas-liquid contactor is being pursued through a series of laboratory experiments. A 100 GPM, low pressure rotary contactor system has been assembled at IGT`s Energy Development Center to examine the fluid dynamic behavior of this type of contactor. The studies are determining the effects of liquid viscosity, liquid surface tension and operating conditions on liquid residence times and flooding limits.

  13. Using 3D LIF to Investigate and Improve Performance of a Multichamber Ozone Contactor

    EPA Science Inventory

    Three-dimensional laser-induced fluorescence (3DLIF) was applied to visualize and quantitatively analyze hydrodynamics and mixing in a multi-chamber ozone contactor, the most widely used design for water disinfection. The results suggested that the mixing was characterized by ext...

  14. International Space Station (ISS) Plasma Contactor Unit (PCU) Utilization Plan Assessment Update

    NASA Technical Reports Server (NTRS)

    Hernandez-Pellerano, Amri; Iannello, Christopher J.; Wollack, Edward J.; Wright, Kenneth H.; Garrett, Henry B.; Ging, Andrew T.; Katz, Ira; Keith, R. Lloyd; Minow, Joseph I.; Willis, Emily M.; Schneider, Todd A.; Whittlesey, Albert C.

    2014-01-01

    The NASA Engineering and Safety Center (NESC) received a request to support the Assessment of the International Space Station (ISS) Plasma Contactor Unit (PCU) Utilization Update. The NESC conducted an earlier assessment of the use of the PCU in 2009. This document contains the outcome of the assessment update.

  15. Temperature control in a 30 stage, 5-cm Centrifugal Contactor Pilot Plant

    SciTech Connect

    Jack D. Law; Troy G. Garn; David H. Meikrantz

    2009-09-01

    Temperature profile testing was performed using a 30 stage 5-cm centrifugal contactor pilot plant. These tests were performed to evaluate the ability to control process temperature by adjusting feed solution temperatures. This would eliminate the need for complex jacketed heat exchanger installation on the centrifugal contactors. Thermocouples were installed on the inlet and outlets of each stage, as well as directly in the mixing zone of several of the contactor stages. Lamp oil, a commercially available alkane mixture of C14 to C18 chains, and tap water adjusted to pH 2 with nitric acid were the solution feeds for the temperature profile testing. Temperature data profiles for an array of total throughputs and contactor rpm values for both single-phase and two-phase systems were collected with selected profiles. The total throughput ranged from 0.5-1.4 L/min with rotor speeds from 3500-4000 rpm. Inlet solution temperatures ranging from ambient up to 50 °C were tested. Results of the two-phase temperature profile testing are detailed

  16. Evaluation of Argonne 9-cm and 10-cm Annular Centrifugal Contactors for SHINE Solution Processing

    SciTech Connect

    Wardle, Kent E.; Pereira, Candido; Vandegrift, George

    2015-02-01

    Work is in progress to evaluate the SHINE Medical Technologies process for producing Mo-99 for medical use from the fission of dissolved low-enriched uranium (LEU). This report addresses the use of Argonne annular centrifugal contactors for periodic treatment of the process solution. In a letter report from FY 2013, Pereira and Vandegrift compared the throughput and physical footprint for the two contactor options available from CINC Industries: the V-02 and V-05, which have rotor diameters of 5 cm and 12.7 cm, respectively. They suggested that an intermediately sized “Goldilocks” contactor might provide a better balance between throughput and footprint to meet the processing needs for the uranium extraction (UREX) processing of the SHINE solution to remove undesired fission products. Included with the submission of this letter report are the assembly drawings for two Argonne-design contactors that are in this intermediate range—9-cm and 10-cm rotors, respectively. The 9-cm contactor (drawing number CE-D6973A, stamped February 15, 1978) was designed as a single-stage unit and built and tested in the late 1970s along with other size units, both smaller and larger. In subsequent years, a significant effort to developed annular centrifugal contactors was undertaken to support work at Hanford implementing the transuranic extraction (TRUEX) process. These contactors had a 10-cm rotor diameter and were fully designed as multistage units with four stages per assembly (drawing number CMT-E1104, stamped March 14, 1990). From a technology readiness perspective, these 10-cm units are much farther ahead in the design progression and, therefore, would require significantly less re-working to make them ready for UREX deployment. Additionally, the overall maximum throughput of ~12 L/min is similar to that of the 9-cm unit (10 L/min), and the former could be efficiently operated over much of the same range of throughput. As a result, only the 10-cm units are considered here

  17. Evaluation of 5-cm Centrifugal Contactor Hydraulic and Mass Transfer Performance for Caustic-Side Solvent Extraction of Cesium

    SciTech Connect

    Birdwell, J.F.

    2001-09-12

    A test program has been conducted in which the use of pilot-scale centrifugal solvent extraction contactors for cesium removal from an alkaline waste stream has been successfully demonstrated. The program was designed specifically to evaluate the use of centrifugal contactors having 5-cm-diam rotors for the removal of cesium from alkaline high-level waste (HLW) that was generated and is being stored at the U.S. Department of Energy's Savannah River Site (SRS). The removal of cesium from this waste is highly desirable because it will reduce the volume of waste that must be treated and disposed of as HLW. The parameters applied in the test effort are those that have been established for the Caustic-Side Solvent Extraction (CSSX) process, a multistage extraction operation that has been designed by researchers at Oak Ridge National Laboratory (ORNL) and Argonne National Laboratory (ANL). In the CSSX process, cesium is extracted by calix(4)arene-bis-(fert-octylbenzo-crown-6), commonly referred to as BOBCalixC6. The extract is scrubbed with dilute (0.05 M) nitric acid, both to remove coextracted elements (primarily potassium and sodium) and to adjust the pH of the extract to facilitate recovery of the cesium. The scrubbed solvent is contacted with 0.001 M HNO{sub 3}, which results in the stripping of the cesium from the solvent into the aqueous acid. The CSSX process flow rates have been established so to produce a cesium concentration in the strip effluent that is 12 to 15 times the concentration in the waste stream that enters the extraction section of the cascade. Results from initial hydraulic testing of a commercially available 5-cm contactor under CSSX conditions indicated that the mixing of feed solutions within the unit (which is critical to efficient solute transfer) was limited by a feature of the contactor that was designed to increase throughput and improve separation performance. In the design, phase separation is improved by reducing turbulence within the

  18. Review of hydrophilic PP membrane for organic waste removal

    NASA Astrophysics Data System (ADS)

    Ariono, Danu; Wardani, Anita Kusuma

    2017-05-01

    The acceleration of industrialization in developing countries has given an impact of environmental pollution rapidly, such as contamination of groundwater with organic waste. To solve this problem, some membrane techniques have been performed to remove organic waste from water, such as membrane contactors, membrane bioreactors, and supported liquid membranes. Polypropylene (PP) membrane is one of the promising candidates for these membrane processes due to its chemical stability, low cost, good mechanical resistance, and being easily available. However, different processes require membranes with different surface properties. Hydrophobic PP membranes with excellent chemical stability can be directly used in membrane contactors, in which the organic phase wets the porous membrane and slightly excessive pressure applied to the other phase. On the other hand, hydrophilization of PP membrane is necessary for some other processes, such as for fouling reduction on membrane bioreactors due to organic matters deposition. The aim of this paper is to give a brief overview of removal of organic waste by PP membrane. Moreover, the effects of PP surface hydrophilization on antifouling properties are also discussed.

  19. Evaluation of high-efficiency gas-liquid contactors for natural gas processing. Semi-annual report, April--September 1994

    SciTech Connect

    1994-11-01

    Objective was to ensure reliable supply of high-quality natural gas by reducing the cost of treating subquality natural gas containing H{sub 2}O, CO{sub 2}, H{sub 2}S and/or trace quantities of other gaseous impurities by applying high-efficiency rotating and structured packing gas liquid contactors. The work included analysis of base case residence time, viscosity studies on low pressure rotary contactor system, and surface tension studies on the contactor.

  20. Temperature Profile Measurements in a Newly Constructed 30-Stage 5 cm Centrifugal Contactor pilot Plant

    SciTech Connect

    Troy G. Garn; Dave H. Meikrantz; Mitchell R. Greenhalgh; Jack D. Law

    2008-09-01

    An annular centrifugal contactor pilot plant incorporating 30 stages of commercial 5 cm CINC V-02 units has been built and operated at INL during the past year. The pilot plant includes an automated process control and data acquisitioning system. The primary purpose of the pilot plant is to evaluate the performance of a large number of inter-connected centrifugal contactors and obtain temperature profile measurements within a 30-stage cascade. Additional solvent extraction flowsheet testing using stable surrogates is also being considered. Preliminary hydraulic testing was conducted with all 30 contactors interconnected for continuous counter-current flow. Hydraulic performance and system operational tests were conducted successfully but with higher single-stage rotor speeds found necessary to maintain steady interstage flow at flowrates of 1 L/min and higher. Initial temperature profile measurements were also completed in this configuration studying the performance during single aqueous and two-phase counter-current flow at ambient and elevated inlet solution temperatures. Temperature profile testing of two discreet sections of the cascade required additional feed and discharge connections. Lamp oil, a commercially available alkane mixture of C14 to C18 chains, and tap water adjusted to pH 2 were the solution feeds for all the testing described in this report. Numerous temperature profiles were completed using a newly constructed 30-stage centrifugal contactor pilot plant. The automated process control and data acquisition system worked very well throughout testing. Temperature data profiles for an array of total flowrates (FT) and contactor rpm values for both single-phase and two-phase systems have been collected with selected profiles and comparisons reported. Total flowrates (FT) ranged from 0.5-1.4 L/min with rotor speeds from 3500-4000 rpm. Solution inlet temperatures ranging from ambient up to 50° C were tested. Ambient temperature testing shows that a

  1. Theory of plasma contactors in ground-based experiments and low earth orbit

    NASA Technical Reports Server (NTRS)

    Gerver, M. J.; Hastings, D. E.; Oberhardt, M. R.

    1990-01-01

    An examination of several models of electron collection by plasma contactors leads to a definition of the range of validity and applicability for each model. It is noted that most present ground-based experiments are of limited relevance to space applications of plasma contactors, since they operate in a regime where the magnetic field and effective collisions are at most only marginally important. An exception is the experiment of Stenzel and Urrutia (1986), which examined a plasma whose electron Larmor radius was small by comparison to the scale of the potential, and in which the anomalous transport of electrons across the magnetic field was important. The enhanced electron current was not continuous in time, but occurred in periodic bursts as the instabilities periodically emerged, saturated, and decayed.

  2. Hybrid multiphase CFD simulation for liquid-liquid interfacial area prediction in annular centrifugal contactors

    SciTech Connect

    Wardle, K.E.

    2013-07-01

    Liquid-liquid contacting equipment used in solvent extraction processes has the dual purpose of mixing and separating two immiscible fluids. Consequently, such devices inherently encompass a wide variety of multiphase flow regimes. A hybrid multiphase computational fluid dynamics (CFD) solver which combines the Eulerian multi-fluid method with VOF (volume of fluid) sharp interface capturing has been developed for application to annular centrifugal contactors. This solver has been extended to enable prediction of mean droplet size and liquid-liquid interfacial area through a single moment population balance method. Simulations of liquid-liquid mixing in a simplified geometry and a model annular centrifugal contactor are reported with droplet breakup/coalescence models being calibrated versus available experimental data. Quantitative comparison is made for two different housing vane geometries and it is found that the predicted droplet size is significantly smaller for vane geometries which result in higher annular liquid holdup.

  3. Measurement of Noise Produced by a Plasma Contactor Operating in Ground Based Facilities

    NASA Technical Reports Server (NTRS)

    Snyder, Steve

    1996-01-01

    Methods to measure electric field fluctuations accurately in a plasma with an active monopole antenna are described. It is shown that the conductive surfaces of the antenna must be adequately isolated from the ambient plasma and that the monopole must be sufficiently short to avoid antenna amplifier saturation. Experimental results illustrate that the noise produced by plasma contactor operation and sensed by the antenna is due to plasma phenomena and is not induced by laboratory power supplies. A good correlation is shown between the current fluctuations in the contactor electrical circuit and the noise detected by the antenna. A large body of experimental data support the conclusion that the majority of noise sensed by the antenna at frequencies less than 1 MHz is due to current fluctuations (electrostatic waves) in the plasma adjacent to the antenna and not to electromagnetic wave radiation. Caution is suggested when comparing antenna noise measurements to conventional specifications for radiated emissions.

  4. Catalytic membrane reactor for water and wastewater treatment

    NASA Astrophysics Data System (ADS)

    Heng, Samuel

    A double membrane reactor was fabricated and assessed for continuous treatment of water containing organic contaminants by ozonation. This innovative reactor consisted of a zeolite membrane prepared on the inner surface of a porous a-alumina support, which served as water selective extractor and active contactor, and a porous stainless membrane which was the ozone gas diffuser. The coupling of membrane separation and chemical oxidation was found to be highly beneficial to both processes. The total organic carbon (TOC) removal rate at the retentate was enhanced by up to 2.2 times, as compared to membrane ozonation. Simultaneously, clean water (< 2 mg C.L-1 ) was consistently produced on the permeate side, using a feed solution containing up to 1000 mg C.L-1, while the retentate was concentrated and treated. Most significantly, the addition of an adsorbing material, as a bed or a coated layer, onto the pores of the membrane support, was shown to further enhance TOC degradation, permeated TOC concentration, permeate flux, and moreover, ozone yield. The achievements of this project included: (1) The development of a novel low-temperature zeolite membrane activation method that generates consistently high quality membranes (i.e. high reproducibility and fewer defects). (2) The demonstration that gamma-alumina and gamma-alumina supported catalysts do not have significant activity and that the TOC removal enhancement usually observed during catalytic ozonation was due primarily to the contribution of adsorption and metal leaching. Thermogravimetric analysis (TGA) and elemental analysis (EA) of the spent catalyst showed that, during catalytic ozonation, oxygenated by-products of increased adsorbability were concentrated onto the gamma-alumina contactor, and were subsequently degraded. (3) The development of a method for coating high surface area gamma-alumina layers onto the grains of zeolite membrane support used as the active membrane contactor.

  5. Entrainment of Solvent in Aqueous Stream from CINC V-5 Contactor

    SciTech Connect

    Fink, S. D.; Restivo, M. L.; Peters, T. B.; Fowley, M. D.; Burns, D. B.; Smith, W. M. Jr.; Fondeur, F. F.; Crump, S. L.; Norato, M. A.; Herman, D. T.; Nash, C. A.

    2005-04-29

    Personnel completed a rapid study of organic entrainment during operation of a CINC V-5 contactor under prototypical conditions covering the range of expected MCU operation. The study only considered the entrainment of organic into the strip acid effluent destined for the Defense Waste Processing Facility. Based on this work, the following observations are noted: (1) Concentrations of total organic from the contactor discharge, based upon modifier measurements, in the acid typically averaged 330 ppm{sub m}, for a range to 190-610 ppm{sub m}. (2) Entrained droplet sizes remained below 18 microns for samples collected at the decanter outlet and below 11 microns for samples taken from the contactor discharge. (3) Scouting tests showed that a vendor coalescer material promotes coalescence of smaller size droplets from the decanter effluent. (4) Personnel observed a previously unreported organic impurity in the solvent used for this study. Additional efforts are needed to ascertain the source of the impurity and its implication on the overall process. (5) Process throughputs and planned operating conditions result in very stable hydraulics, suggesting that the MCU stripping stages will have spare operating capacity. (6) The V-5 contactors show operated with relatively cool surfaces under the planned operating conditions. (7) If operating conditions result in an imbalance of the relative mixing and separation conditions within the contactor, a very stable emulsion may result. In this instance, the emulsion remained stable for weeks. The imbalance in this study resulted from use of improperly sized weir plates. (8) Personnel demonstrated an effective means of recovering emulsified solvent following a non-optimal equipment configuration. The protocols developed may offer benefit for MCU and SWPF operations. (9) This study developed and demonstrated the effectiveness of several analytical methods for support of the Caustic-Side Solvent Extraction process including infrared

  6. Characterization of full-scale carbon contactors for siloxane removal from biogas using online Fourier transform infrared spectroscopy.

    PubMed

    Hepburn, C A; Martin, B D; Simms, N; McAdam, E J

    2015-01-01

    In this study, online Fourier transform infrared (FTIR) spectroscopy has been used to generate the first comprehensive characterization of full-scale carbon contactors for siloxane removal from biogas. Using FTIR, two clear operational regions within the exhaustion cycle were evidenced: an initial period of pseudo-steady state where the outlet siloxane concentration was consistently below the proposed siloxane limits; and a second period characterized by a progressive rise in outlet siloxane concentration during and after breakthrough. Due to the sharp breakthrough front identified, existing detection methods (which comprise field sampling coupled with laboratory-based chromatographic determination) are insufficiently responsive to define breakthrough, thus carbon contactors currently remain in service while providing limited protection to the combined heat and power engine. Integration of the exhaustion cycle to breakthrough identified average specific media capacities of 8.5-21.5 gsiloxane kg(-1)GAC, which are lower than that has been reported for vapour phase granular activated carbon (GAC). Further speciation of the biogas phase identified co-separation of organic compounds (alkanes and aromatics), which will inevitably reduce siloxane capacity. However, comparison of the five full-scale contactors identified that greater media capacity was accessible through operating contactors at velocities sufficient to diminish axial dispersion effects. In addition to enabling significant insight into gas phase GAC contactors, the use of FTIR for online control of GAC for siloxane removal is also presented.

  7. Hydraulic and Clean-in-Place Evaluations for a 12.5-cm Annular Centrifugal Contactor at INL

    SciTech Connect

    Troy G. Garn; David H. Meikrantz; Nick R. Mann; Jack D. Law; Terry A. Todd

    2008-09-01

    Hydraulic and Clean-in-Place Evaluations for a 12.5 cm Annular Centrifugal Contactor at the INL Troy G. Garn, Dave H. Meikrantz, Nick R. Mann, Jack D. Law, Terry A. Todd Idaho National Laboratory Commercially available, Annular Centrifugal Contactors (ACC) are currently being evaluated for processing dissolved nuclear fuel solutions to selectively partition integrated elements using solvent extraction technologies. These evaluations include hydraulic and clean-in-place (CIP) testing of a commercially available 12.5 cm unit. Data from these evaluations is used to support design of future nuclear fuel reprocessing facilities. Hydraulic testing provides contactor throughput performance data on two-phase systems for a wide range of operating conditions. Hydraulic testing results on a simple two-phase oil and water system followed by a 30 % Tributyl phosphate in N-dodecane / nitric acid pair are reported. Maximum total throughputs for this size contactor ranged from 20 to 32 liters per minute without significant other phase carryover. A relatively new contactor design enhancement providing Clean-in-Place capability for ACCs was also investigated. Spray nozzles installed into the central rotor shaft allow the rotor internals to be cleaned, offline. Testing of the solids capture of a diatomaceous earth/water slurry feed followed by CIP testing was performed. Solids capture efficiencies of >95% were observed for all tests and short cold water cleaning pulses proved successful at removing solids from the rotor.

  8. PUMA - a new mathematical model for the rapid calculation of steady-state concentration profiles in mixer-settler extraction, partitioning, and stripping contactors using the Purex process

    SciTech Connect

    Geldard, J.F.

    1986-11-01

    The mathematical basis for a computer code PUMA (Plutonium-Uranium-Matrix-Algorithm) is described. The code simulates steady-state concentration profiles of solvent extraction contactors used in the Purex process, directly without first generating the transient behavior. The computational times are reduced, with no loss of accuracy, by about tenfold over those required by codes that generate the steady-state profiles via transient state conditions. Previously developed codes that simulate the steady-state conditions directly are not applicable to partitioning contactors, whereas PUMA is applicable to all contactors in the Purex process. Since most difficulties are encountered with partitioning contactors when simulating steady-state profiles via transient state conditions, it is with these contactors that the greatest saving in computer times is achieved.

  9. Sweeping Gas Membrane Desalination Using Commercial Hydrophobic Hollow Fiber Membranes

    SciTech Connect

    EVANS, LINDSEY; MILLER, JAMES E.

    2002-01-01

    Water shortages affect 88 developing countries that are home to half of the world's population. In these places, 80-90% of all diseases and 30% of all deaths result from poor water quality. Furthermore, over the next 25 years, the number of people affected by severe water shortages is expected to increase fourfold. Low cost methods of purifying freshwater, and desalting seawater are required to contend with this destabilizing trend. Membrane distillation (MD) is an emerging technology for separations that are traditionally accomplished via conventional distillation or reverse osmosis. As applied to desalination, MD involves the transport of water vapor from a saline solution through the pores of a hydrophobic membrane. In sweeping gas MD, a flowing gas stream is used to flush the water vapor from the permeate side of the membrane, thereby maintaining the vapor pressure gradient necessary for mass transfer. Since liquid does not penetrate the hydrophobic membrane, dissolved ions are completely rejected by the membrane. MD has a number of potential advantages over conventional desalination including low temperature and pressure operation, reduced membrane strength requirements, compact size, and 100% rejection of non-volatiles. The present work evaluated the suitability of commercially available technology for sweeping gas membrane desalination. Evaluations were conducted with Celgard Liqui-Cel{reg_sign} Extra-Flow 2.5X8 membrane contactors with X-30 and X-40 hydrophobic hollow fiber membranes. Our results show that sweeping gas membrane desalination systems are capable of producing low total dissolved solids (TDS) water, typically 10 ppm or less, from seawater, using low grade heat. However, there are several barriers that currently prevent sweeping gas MD from being a viable desalination technology. The primary problem is that large air flows are required to achieve significant water yields, and the costs associated with transporting this air are prohibitive. To

  10. Operational Status of the International Space Station Plasma Contactor Hollow Cathode Assemblies July 2001 to May 2013

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Yim, John T.; Patterson, Michael J.; Dalton, Penni J.

    2013-01-01

    The International Space Station has onboard two Aerojet Rocketdyne developed plasma contactor units that perform the function of charge control. The plasma contactor units contain NASA Glenn Research Center developed hollow cathode assemblies. NASA Glenn Research Center monitors the on-orbit operation of the flight hollow cathode assemblies. As of May 31, 2013, HCA.001-F has been ignited and operated 123 times and has accumulated 8072 hours of operation, whereas, HCA.003-F has been ignited and operated 112 times and has accumulated 9664 hours of operation. Monitored hollow cathode ignition times and anode voltage magnitudes indicate that they continue to operate nominally.

  11. Operational Status of the International Space Station Plasma Contactor Hollow Cathode Assemblies from July 2011 to May 2013

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Yim, John T.; Patterson, Michael J.; Dalton, Penni J.

    2014-01-01

    The International Space Station has onboard two Aerojet Rocketdyne developed plasma contactor units that perform the function of charge control. The plasma contactor units contain NASA Glenn Research Center developed hollow cathode assemblies. NASA Glenn Research Center monitors the onorbit operation of the flight hollow cathode assemblies. As of May 31, 2013, HCA.001-F has been ignited and operated 123 times and has accumulated 8072 hours of operation, whereas, HCA.003-F has been ignited and operated 112 times and has accumulated 9664 hours of operation. Monitored hollow cathode ignition times and anode voltage magnitudes indicate that they continue to operate nominally.

  12. DETERMINATION OF LIQUID FILM THICKNESS FOLLOWING DRAINING OF CONTACTORS, VESSELS, AND PIPES IN THE MCU PROCESS

    SciTech Connect

    Poirier, M; Fernando Fondeur, F; Samuel Fink, S

    2006-06-06

    The Department of Energy (DOE) identified the caustic side solvent extraction (CSSX) process as the preferred technology to remove cesium from radioactive waste solutions at the Savannah River Site (SRS). As a result, Washington Savannah River Company (WSRC) began designing and building a Modular CSSX Unit (MCU) in the SRS tank farm to process liquid waste for an interim period until the Salt Waste Processing Facility (SWPF) begins operations. Both the solvent and the strip effluent streams could contain high concentrations of cesium which must be removed from the contactors, process tanks, and piping prior to performing contactor maintenance. When these vessels are drained, thin films or drops will remain on the equipment walls. Following draining, the vessels will be flushed with water and drained to remove the flush water. The draining reduces the cesium concentration in the vessels by reducing the volume of cesium-containing material. The flushing, and subsequent draining, reduces the cesium in the vessels by diluting the cesium that remains in the film or drops on the vessel walls. MCU personnel requested that Savannah River National Laboratory (SRNL) researchers conduct a literature search to identify models to calculate the thickness of the liquid films remaining in the contactors, process tanks, and piping following draining of salt solution, solvent, and strip solution. The conclusions from this work are: (1) The predicted film thickness of the strip effluent is 0.010 mm on vertical walls, 0.57 mm on horizontal walls and 0.081 mm in horizontal pipes. (2) The predicted film thickness of the salt solution is 0.015 mm on vertical walls, 0.74 mm on horizontal walls, and 0.106 mm in horizontal pipes. (3) The predicted film thickness of the solvent is 0.022 mm on vertical walls, 0.91 mm on horizontal walls, and 0.13 mm in horizontal pipes. (4) The calculated film volume following draining is: (a) Salt solution receipt tank--1.6 gallons; (b) Salt solution feed

  13. Vacuum contactor retrofit of a low-voltage power circuit breaker

    SciTech Connect

    Fischer, J.D.

    1995-12-31

    Due to a misapplication of low-voltage power circuit breakers on high-cycling motor-starting services, the electrically operated mechanisms failed due to the large number of spring-charging, closing and opening cycles. Various options for correcting the problem were evaluated, and a vacuum contactor retrofit of the circuit breaker was selected for some of them. The vacuum starter units are electrically and mechanically interchangeable with the power circuit breakers. The paper discusses the design considerations and operating differences resulting from the technology conversion. It also discusses the differences in rating, function, and application.

  14. Keeping Accountability Systems Accountable

    ERIC Educational Resources Information Center

    Foote, Martha

    2007-01-01

    The standards and accountability movement in education has undeniably transformed schooling throughout the United States. Even before President Bush signed the No Child Left Behind (NCLB) Act into law in January 2002, mandating annual public school testing in English and math for grades 3-8 and once in high school, most states had already…

  15. Correlation of Hollow Cathode Assembly and Plasma Contactor Data from Ground Testing and In-Space Operation on the International Space Station

    NASA Technical Reports Server (NTRS)

    Kovalkeski, Scott D.; Patterson, Michael J.; Soulas, George C.

    2001-01-01

    Charge control on the International Space Station (ISS) is currently being provided by two plasma contactor units (PCUs). The plasma contactor includes a hollow cathode assembly (HCA), power processing unit and Xe gas feed system. The hollow cathode assemblies in use in the ISS plasma contactors were designed and fabricated at the NASA Glenn Research Center. Prequalification testing of development HCAs as well as acceptance testing of the flight HCAs is presented. Integration of the HCAs into the Boeing North America built PCU and acceptance testing of the PCU are summarized in this paper. Finally, data from the two on-orbit PCUs is presented.

  16. A Review of Testing of Hollow Cathodes for the International Space Station Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Kovaleski, S. D.; Patterson, M. J.; Soulas, G. C.; Sarver-Verhey, T. R.

    2001-01-01

    Since October 2000, two plasma contactors have been providing charge control on the International Space Station (ISS). At the heart of each of the two plasma contactors is a hollow cathode assembly (HCA) that produces the contacting xenon plasma. The HCA is the result of 9 years of design and testing at the NASA Glenn Research Center. This paper summarizes HCA testing that has been performed to date. As of this time, one cathode has demonstrated approximately 28,000 hr of lifetime during constant, high current use. Another cathode, HCA.014. has demonstrated 42,000 ignitions before cathode heater failure. In addition to these cathodes, four cathodes. HCA.006, HCA.003, HCA.010, and HCA.013 have undergone cyclic testing to simulate the variable current demand expected on the ISS. HCA.006 accumulated 8,000 hr of life test operation prior to being voluntarily stopped for analysis before the flight units were fabricated. HCA.010 has accumulated 15,876 hr of life testing, and 4,424 ignitions during ignition testing. HCA.003 and HCA.0 13 have accumulated 12,415 and 18,823 hr of life testing respectively.

  17. Drop mass transfer in a microfluidic chip compared to a centrifugal contactor

    DOE PAGES

    Nemer, Martin B.; Roberts, Christine C.; Hughes, Lindsey G.; ...

    2014-06-13

    A model system was developed for enabling a multiscale understanding of centrifugal-contactor liquid–liquid extraction.The system consisted of Nd(III) + xylenol orange in the aqueous phase buffered to pH =5.5 by KHP, and dodecane + thenoyltrifluroroacetone (HTTA) + tributyphosphate (TBP) in the organic phase. Diffusion constants were measured for neodymium in both the organic and aqueous phases, and the Nd(III) partition coefficients were measured at various HTTA and TBP concentrations. A microfluidic channel was used as a high-shear model environment to observe mass-transfer on a droplet scale with xylenol orange as the aqueous-phase metal indicator; mass-transfer rates were measured quantitatively inmore » both diffusion and reaction limited regimes on the droplet scale. Lastly, the microfluidic results were comparable to observations made for the same system in a laboratory scale liquid–liquid centrifugal contactor, indicating that single drop microfluidic experiments can provide information on mass transfer in complicated flows and geometries.« less

  18. Calibrating and deriving physical parameters using plasma contactor data from the international space station

    NASA Astrophysics Data System (ADS)

    Bering, Edgar A.; Koontz, Steven L.; Evans, David S.; Katz, Ira; Gardner, Barbara M.; Suggs, Robert M.; Minow, Joseph I.; Dalton, Penni J.; Feruson, Dale C.; Hillard, G. Barry; Counts, Jerry L.; Barsamian, Hagop; Kern, John; Mikatarian, Ronald

    2003-12-01

    The International Space Station (ISS) regularly passes through the southern auroral oval south of Australia. The ISS has two plasma contactors that emit the electron currents needed to balance electron collection by surfaces such as the lattice of bare rods on the solar array masts. These electron currents exceed 0.1 A at times. The largest currents are observed in the auroral oval south of Australia. On the space station, the solar array 40 m long masts each have over 400 m of stainless steel tensioning rods. When subject to orbital v × B· l induced potentials, the rods collect substantial currents from the ionosphere. Maximum v × B· l potentials are generated near the magnetic poles. The plasma contactor emission current can be converted to an estimate of plasma density and calibrated using Floating Potential Probe (FPP) and other data. These measurements show that the plasma density in the nighttime auroral ionosphere is frequently several times that predicted by the International Reference Ionosphere (IRI)-90 and IRI2001 models.

  19. Calibrating and deriving physical parameters using plasma contactor data from the International Space Station

    NASA Astrophysics Data System (ADS)

    Bering, E.

    The International Space Station (ISS) regularly passes through the southern auroral oval south of Australia. The ISS has two plasma contactors that emit the electron currents needed to balance electron collection by surfaces such as the lattice of bare rods on the solar array masts. These electron currents exceed 0.1 A at times. The largest currents are observed in the auroral oval south of Australia. On the space station, the solar array 40 m long masts each have over 400 m of stainless steel tensioning rods. When subject to orbital v×B-l induced potentials, the rods collect substantial currents from the ionosphere. Maximum v×B-l potentials are generated near the magnetic poles. The plasma contactor emission current can be converted to an estimate of plasma density and calibrated using Floating potential Probe (FPP) and other data. These measurements show that the plasma density in the nighttime auroral ionosphere is frequently several times that predicted by the International Reference Ionosphere (IRI)-90 and IRI-2001 models.

  20. Drop mass transfer in a microfluidic chip compared to a centrifugal contactor

    SciTech Connect

    Nemer, Martin B.; Roberts, Christine C.; Hughes, Lindsey G.; Wyatt, Nicholas B.; Brooks, Carlton F.; Rao, Rekha

    2014-06-13

    A model system was developed for enabling a multiscale understanding of centrifugal-contactor liquid–liquid extraction.The system consisted of Nd(III) + xylenol orange in the aqueous phase buffered to pH =5.5 by KHP, and dodecane + thenoyltrifluroroacetone (HTTA) + tributyphosphate (TBP) in the organic phase. Diffusion constants were measured for neodymium in both the organic and aqueous phases, and the Nd(III) partition coefficients were measured at various HTTA and TBP concentrations. A microfluidic channel was used as a high-shear model environment to observe mass-transfer on a droplet scale with xylenol orange as the aqueous-phase metal indicator; mass-transfer rates were measured quantitatively in both diffusion and reaction limited regimes on the droplet scale. Lastly, the microfluidic results were comparable to observations made for the same system in a laboratory scale liquid–liquid centrifugal contactor, indicating that single drop microfluidic experiments can provide information on mass transfer in complicated flows and geometries.

  1. INACTIVATION OF CRYPTOSPORIDIUM OOCYSTS IN A PILOT-SCALE OZONE BUBBLE-DIFFUSER CONTACTOR - II: MODEL VALIDATION AND APPLICATION

    EPA Science Inventory

    The ADR model developed in Part I of this study was successfully validated with experimenta data obtained for the inactivation of C. parvum and C. muris oocysts with a pilot-scale ozone-bubble diffuser contactor operated with treated Ohio River water. Kinetic parameters, required...

  2. Design and evaluation of hydraulic baffled-channel PAC contactor for taste and odor removal from drinking water supplies.

    PubMed

    Kim, Young-Il; Bae, Byung-Uk

    2007-05-01

    Based on the concept of hydraulic flocculator, a baffled-channel powdered activated carbon (PAC) contactor, placed before the rapid-mixing basin, was designed and evaluated for removal of taste and odor (T&O) in drinking water. PAC adsorption kinetic tests for raw water samples were conducted for selection of design parameters related to contact time and degree of mixing. Within the tested range of velocity gradient (G) from 18 to 83s(-1), mixing had a relatively minor effect on the adsorption kinetics of the PAC. The hydrodynamic characteristics of the pilot-scale horizontally and vertically baffled-channel PAC contactor were investigated by tracer tests. It was found that the plug flow fractions of vertically baffled-channel PAC contactor (vBPC) were higher than those of the horizontally baffled-channel PAC contactor (hBPC) for the same bend width or bend height. However, the hBPC seems to be more appropriate than the vBPC in terms of construction and maintenance. The geosmin and MIB removal rate increased with the number of baffles, PAC dose and contact time increased regardless of bend width in the pilot-scale hBPC. The pair of full-scale hBPCs at Pohang water treatment plant, having a design capacity of 6.5x10(4)m(3)/d with 20min of hydraulic retention time with a safety factor of 2, was designed based on lab- and pilot-scale experimental results. Under a velocity gradient of 20s(-1), the number of baffles to be installed was calculated to be 20 with a space of about 2m between each baffle, resulting in a hydraulic head loss through the contactor of about 0.056m. The successful application of hBPC for T&O removal from drinking water supplies should provide momentum for developing more effective treatment methods.

  3. Properties of the Auroral Zone Ionosphere Inferred Using Plasma Contactor Data From the International Space Station

    NASA Astrophysics Data System (ADS)

    Koontz, S. L.; Bering, E. A.; Evans, D. S.; Katz, I.; Gardner, B. M.; Suggs, R. M.; Minow, J. I.; Dalton, P. J.; Ferguson, D. C.; Hillard, G. B.; Counts, J. L.; Barsamian, H.; Kern, J.; Mikatarian, R.

    2001-12-01

    Comparison of the auroral electron precipitation maps produced by the NOAA POES satellite constellation with the flight path of the International Space Station (ISS) reveals that ISS regularly passes through the southern auroral oval south of Australia. During the first few months of 2001, ISS configuration and flight attitude were such that tensioning rods on the space station solar array masts could collect current from the ionosphere in the same way as a bare wire antenna or electrodynamic tether. The ISS has two plasma contactors that emit the electron currents needed to balance electron collection by surfaces such as the lattice of bare rods on the solar array masts. During this period, these electron currents exceeded 0.1 A at times. The largest currents were observed in the auroral oval south of Australia, often after orbital sunset. On the space station, the solar array 40 m long masts each have over 400 m of stainless steel tensioning rods. When subject to orbital vxBṡl induced potentials, the rods collect substantial currents from the ionosphere. Models of the mast collection processes based upon J. R. Sanmartin's bare wire collection theory have been incorporated into computer codes that integrate models of the station geometry, orbital motion, earth's magnetic field, and ionosphere to obtain plasma contactor emission currents. During the period being analyzed, the station flew in an orientation such that the masts were perpendicular to the orbital velocity vector, and parallel to the earth's surface. Maximum vxBṡl potentials are generated near the magnetic poles. The current drawn by the masts is linearly proportional to the plasma density. The plasma contactor emission current can be converted to an estimate of plasma density. These measurements show that the plasma density in the nighttime auroral ionosphere is frequently several times that predicted by the International Reference Ionosphere (IRI)-90 and IRI-2001 models. We will discuss how the

  4. Examination of Organic Carryover from 2-cm Contactors to Support the Modular CSSX Unit

    SciTech Connect

    Nash, Charles A.; Norato, Michael A.; Walker; D. Douglas; Pierce, Robert A.; Eubanks, Ronnye A.; Clark, James D.; Smith, Wilson M. Jr.; Crump, Stephen L.; Nelson, D. Zane; Fink, Samuel D.; Peters, Thomas B.; May, Cecil G.; Herman, David T.; Bolton, Henry L.

    2005-04-29

    A bank of four 2-cm centrifugal contactors was operated in countercurrent fashion to help address questions about organic carryover for the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). The contactors, having weirs sized for strip operation, were used to examine carryover for both strip effluent (SE) and decontaminated salt solution (DSS). Since only one bank of contactors was available in the short time frame of this work, the organic phase and only one aqueous phase were present in the flow loops at a time. Personnel maintained flowsheet-typical organic phase to aqueous phase (O:A) flow ratios when varying flow rates. Solvent from two different batches were tested with strip solution. In addition, potential mitigations of pH adjustment and coalescing media were examined. The experiment found that organic carryover after decanting averaged 220 ppm by mass with a range of 74 to 417 ppm of Isopar{reg_sign} L for strip effluent (SE)/organic solvent contacts. These values are based on measured modifier. Values were bounded by a value of 95 ppm based upon Isopar{reg_sign} L values as reported. The higher modifier-based numbers are considered more reliable at this time. Carryover of Isopar{reg_sign} L in DSS simulant averaged 77 ppm by mass with a range of 70 to 88 ppm of Isopar{reg_sign} L based on modifier content. The carryover was bounded by a value of 19 ppm based upon Isopar{reg_sign} L values as reported. More work is needed to resolve the discrepancy between modifier and Isopar{reg_sign} L values. The work did not detect organic droplets greater than 18 microns in SE. Strip output contained droplets down to 0.5 micron in size. Droplets in DSS were almost monodisperse by comparison, having a size range 4.7 +/- 1.6 micron in one test and 5.2 +/- 0.8 micron in the second demonstration. Optical microscopy provided qualitative results confirming the integrity of droplet size measurements in this work. Acidic or basic adjustments of aqueous strip solution

  5. On the Operational Status of the ISS Plasma Contactor Hollow Cathodes

    NASA Technical Reports Server (NTRS)

    Burke, Thomas P. (Technical Monitor); Carpenter, Christian B.

    2004-01-01

    The Plasma Contactor Unit (PCU) was developed by the Rocketdyne division of The Boeing Company to control charging of the International Space Station (ISS). Each PCU contains a Hollow Cathode Assembly (HCA), which emits the charge control electrons. The HCAs were designed and fabricated at NASA s Glenn Research Center (GRC). GRC's HCA development program included manufacture of engineering, qualification, and flight model HCAs as well as qualification and wear tests. GRC tracks the on-orbit data for the flight HCAs in order to ascertain their overall health. As of April 5, 2004, 43 ignitions and over 6000 hours have been accumulated on a single unit. The flight HCAs continue to operate flawlessly. This paper will discuss the operation of the HCAs during ground tests and on-orbit operation from initial startup to April 30, 2004.

  6. Bioaugmentation for treating transient 4-fluorocinnamic acid shock loads in a rotating biological contactor.

    PubMed

    Amorim, Catarina L; Duque, Anouk F; Afonso, Carlos M M; Castro, Paula M L

    2013-09-01

    A rotating biological contactor (RBC) was used to treat shock loadings of 4-fluorocinnamic acid (4-FCA). Intermittent 4-FCA shocks of 35 mg L(-1) were applied (ca. 3 months) with only limited mineralization occurring and accumulation of 4-fluorobenzoate (4-FBA) as an intermediate. After bioaugmentation with a degrading bacterium the RBC was able to deal with 4-FCA intermittent loading of 80 mg L(-1) however, a gradual decline in RBC performance occurred, leading to 4-FBA accumulation. The degrading strain was recovered from the biofilm during 2 months but intermittent feeding may have led to diminishing strain numbers. Distinct bacterial communities in the 1st and the 5th and 10th stages of the RBC were revealed by denaturating gradient gel electrophoresis. Several isolates retrieved from the RBC transformed 4-FCA into 4-FBA but only two strains mineralized the compound. Bioaugmentation allowed removal of the fluorinated compound however intermittent feeding may have compromised the bioreactor efficiency.

  7. Hollow cathodes as electron emitting plasma contactors Theory and computer modeling

    NASA Technical Reports Server (NTRS)

    Davis, V. A.; Katz, I.; Mandell, M. J.; Parks, D. E.

    1987-01-01

    Several researchers have suggested using hollow cathodes as plasma contactors for electrodynamic tethers, particularly to prevent the Shuttle Orbiter from charging to large negative potentials. Previous studies have shown that fluid models with anomalous scattering can describe the electron transport in hollow cathode generated plasmas. An improved theory of the hollow cathode plasmas is developed and computational results using the theory are compared with laboratory experiments. Numerical predictions for a hollow cathode plasma source of the type considered for use on the Shuttle are presented, as are three-dimensional NASCAP/LEO calculations of the emitted ion trajectories and the resulting potentials in the vicinity of the Orbiter. The computer calculations show that the hollow cathode plasma source makes vastly superior contact with the ionospheric plasma compared with either an electron gun or passive ion collection by the Orbiter.

  8. Thermal Analysis of AC Contactor Using Thermal Network Finite Difference Analysis Method

    NASA Astrophysics Data System (ADS)

    Niu, Chunping; Chen, Degui; Li, Xingwen; Geng, Yingsan

    To predict the thermal behavior of switchgear quickly, the Thermal Network Finite Difference Analysis method (TNFDA) is adopted in thermal analysis of AC contactor in the paper. The thermal network model is built with nodes, thermal resistors and heat generators, and it is solved using finite difference method (FDM). The main circuit and the control system are connected by thermal resistors network, which solves the problem of multi-sources interaction in the application of TNFDA. The temperature of conducting wires is calculated according to the heat transfer process and the fundamental equations of thermal conduction. It provides a method to solve the problem of boundary conditions in applying the TNFDA. The comparison between the results of TNFDA and measurements shows the feasibility and practicability of the method.

  9. Bacterial Cellulose Production by Gluconacetobacter sp. RKY5 in a Rotary Biofilm Contactor

    NASA Astrophysics Data System (ADS)

    Kim, Yong-Jun; Kim, Jin-Nam; Wee, Young-Jung; Park, Don-Hee; Ryu, Hwa-Won

    A rotary biofilm contactor (RBC) inoculated with Gluconacetobacter sp. RKY5 was used as a bioreactor for improved bacterial cellulose production. The optimal number of disk for bacterial cellulose production was found to be eight, at which bacterial cellulose and cell concentrations were 5.52 and 4.98 g/L. When the aeration rate was maintained at 1.25 vvm, bacterial cellulose and cell concentrations were maximized (5.67 and 5.25 g/L, respectively). The optimal rotation speed of impeller in RBC was 15 rpm. When the culture pH in RBC was not controlled during fermentation, the maximal amount of bacterial cellulose (5.53 g/L) and cells (4.91 g/L) was obtained. Under the optimized culture conditions, bacterial cellulose and cell concentrations in RBC reached to 6.17 and 5.58 g/L, respectively.

  10. The use of the fungus Dichomitus squalens for degradation in rotating biological contactor conditions.

    PubMed

    Novotný, Ceněk; Trošt, Nina; Šlušla, Martin; Svobodová, Kateřina; Mikesková, Hana; Válková, Hana; Malachová, Kateřina; Pavko, Aleksander

    2012-06-01

    Biodegradation potential of Dichomitus squalens in biofilm cultures and rotating biological contactor (RBC) was investigated. The fungus formed thick biofilms on inert and lignocellulosic supports and exhibited stable activities of laccase and manganese peroxidase to reach 40-62 and 25-32% decolorization of anthraquinone Remazol Brilliant Blue R and heterocyclic phthalocyanine dyes, respectively. The decolorization ceased when glucose concentration dropped to 1 mmol l(-1). In RBC reactor, respective decolorizations of Remazol Brilliant Blue R and heterocyclic Methylene Blue and Azure B dyes (50 mg l(-1)) attained 99%, 93%, and 59% within 7, 40 and 200 h. The fungus exhibited tolerance to coliform and non-coliform bacteria on rich organic media, the inhibition occurred only on media containing tryptone and NaCl. The degradation efficiency in RBC reactor, capability to decolorize a wide range of dye structures and tolerance to bacterial stress make D. squalens an organism applicable to remediation of textile wastewaters.

  11. Accounting Curriculum.

    ERIC Educational Resources Information Center

    Prickett, Charlotte

    This curriculum guide describes the accounting curriculum in the following three areas: accounting clerk, bookkeeper, and nondegreed accountant. The competencies and tasks complement the Arizona validated listing in these areas. The guide lists 24 competencies for nondegreed accountants, 10 competencies for accounting clerks, and 11 competencies…

  12. Turbulent dispersion results from gel-sphere processes and application to centrifugal contactors

    SciTech Connect

    Haas, P.A.

    1986-07-01

    Three different devices using controlled velocities of organic liquids were applied to disperse aqueous solutions as drops. One consisted of simple tubes of small diameters. A second contained motionless mixer units inside large tubes. The third employed couette flow of the organic liquid between a cylindrical rotor and a stationary cylinder. These devices were applied to gel-sphere processes in which the liquid drops are converted into solid gel spheres of hydrated metal oxides. The gel-sphere products are good, strong spheres and allow good measurement of the sphere and the drop-size distributions. The drop diameters must be controlled and predictable to allow preparation of product spheres of the desired sizes. Empirical correlations were determined for application to the gel-sphere processes. The theory of turbulent dispersion based on eddy velocities has been developed by Kolmorogoff, Hinze, and others. Davies reviewed this theory and the agreement of theory with four types of dispersion devices for energy dissipation rates of 6 to 400,000 W/g. The gel-sphere results for drop-size distribution are for energy dissipation rates of 10/sup -3/ to 1.5 W/g. Those combined results support the theory of turbulence as the dispersion mechanism over a range of 10/sup 9/ for the rate of energy dissipation. The turbulent dispersion with Couette flow is the mechanism for mixing in an advanced design of centrifugal contactors for solvent extraction. The theory of turbulence is applied to predict drop sizes and mixing power for centrifugal contactors as developed at Oak Ridge National Laboratory (ORNL). 14 refs., 7 figs., 6 tabs.

  13. Sliding-cavity fluid contactors in low-gravity fluids, materials, and biotechnology research.

    PubMed

    Todd, Paul; Vellinger, John C; Sengupta, Shramik; Sportiello, Michael G; Greenberg, Alan R; Krantz, William B

    2002-10-01

    The well-known method of sliding-cavity fluid contactors used by Gosting for diffusion measurements and by Tiselius in electrophoresis has found considerable use in low-gravity research. To date, sliding-cavity contactors have been used in liquid diffusion experiments, interfacial transport experiments, biomolecular crystal growth, biphasic extraction, multistage extraction, microencapsulation, seed germination, invertebrate development, and thin-film casting. Sliding-cavity technology has several advantages for spaceflight: it is simple, it accommodates small samples, samples can be fully enclosed, phases can be combined, multiple samples can be processed at high sample density, real-time observations can be made, and mixed and diffused samples can be compared. An analysis of the transport phenomena that govern the sliding-cavity method is offered. During sliding of one liquid over another flow rates between 0.001 and 0.1m/sec are developed, giving Reynolds numbers in the range 0.1-100. Assuming no slip at liquid-solid boundaries shear rates are of the order 1sec(-1). The measured consequence is the transfer of 2-5% of the content of a cavity to the opposite cavity. In the absence of gravity, buoyancy-driven transport is assumed absent. Transport processes are limited to (1) molecular diffusion, in which reactants diffuse toward one another at rates that depend on their diffusion coefficient and concentration gradient (Fick's second law), (2) solutocapillary (Marangoni) flow driven by surface-tension gradients, (3) capillary flow (drop spreading) at liquid-solid three-phase lines leading to immiscible phase demixing, and (4) vapor-phase diffusive mass transfer in evaporative processes. Quantitative treatment of these phenomena has been accomplished over the past few years in low-gravity research in space and on aircraft.

  14. Evaluation of Mass Transfer Performance for Caustic-Side Solvent Extraction of Cesium in a Conventional 5-cm Centrifugal Contactor

    SciTech Connect

    Birdwell, Jr. J.F.

    2002-02-19

    Tests have been conducted to determine if satisfactory mass transfer performance is achieved using a fully pumping 5-cm centrifugal contactor under conditions present in the Caustic-Side Solvent Extraction (CSSX) process. Tests utilized a commercially available contactor that had been modified by installation of a rotor housing bottom that had straight radial vanes on the process side. As received from the vendor, the housing bottom was equipped with curved (impeller-type) vanes that were intended to promote phase separation by minimizing mixing of influent solutions. Stage efficiencies exceeding 85% were obtained under conditions, present in the extraction section of the CSSX flowsheet. Under CSSX stripping conditions the stage efficiency exceeded 90%. In both cases, the efficiencies obtained exceed the minimum requirement for acceptable transfer of cesium in the CSSX process.

  15. Accomplishing Equilibrium in ALSEP: Demonstrations of Modified Process Chemistry on 3-D Printed Enhanced Annular Centrifugal Contactors

    SciTech Connect

    Brown, M. Alex; Wardle, Kent E.; Lumetta, Gregg; Gelis, Artem V.

    2016-12-01

    Here, the major components of the modified ALSEP process have been demonstrated on a modified 2-cm annular centrifugal contactor with an enhanced mixing zone using stable fission products and radiotracers. The results show that by decreasing the pH of the minor actinide stripping solution, using HEDTA instead of DTPA, and increasing contact time, the process is very effective in separating americium from the lanthanides and the fission products.

  16. Accomplishing Equilibrium in ALSEP: Demonstrations of Modified Process Chemistry on 3-D Printed Enhanced Annular Centrifugal Contactors

    DOE PAGES

    Brown, M. Alex; Wardle, Kent E.; Lumetta, Gregg; ...

    2016-01-01

    The major components of the modified ALSEP process have been demonstrated on a modified 2-cm annular centrifugal contactor with an enhanced mixing zone using stable fission products and radiotracers. The results show that by decreasing the pH of the minor actinide stripping solution, using HEDTA instead of DTPA, and increasing contact time, the process is very effective in separating americium from the lanthanides and the fission products.

  17. Future beam experiments in the magnetosphere with plasma contactors: How do we get the charge off the spacecraft?

    NASA Astrophysics Data System (ADS)

    Delzanno, G. L.; Borovsky, J. E.; Thomsen, M. F.; Moulton, J. D.; MacDonald, E. A.

    2015-05-01

    The idea of using a high-voltage electron beam with substantial current to actively probe magnetic field line connectivity in space has been discussed since the 1970s. However, its experimental realization onboard a magnetospheric spacecraft has never been accomplished because the tenuous magnetospheric plasma cannot provide the return current necessary to keep spacecraft charging under control. In this work, we perform Particle-In-Cell simulations to investigate the conditions under which a high-voltage electron beam can be emitted from a spacecraft and explore solutions that can mitigate spacecraft charging. The electron beam cannot simply be compensated for by an ion beam of equal current, because the Child-Langmuir space charge limit is violated under conditions of interest. On the other hand, releasing a high-density neutral contactor plasma prior and during beam emission is critical in aiding beam emission. We show that after an initial transient controlled by the size of the contactor cloud where the spacecraft potential rises, the spacecraft potential can settle into conditions that allow for electron beam emission. A physical explanation of this result in terms of ion emission into spherical geometry from the surface of the plasma cloud is presented, together with scaling laws of the peak spacecraft potential varying the ion mass and beam current. These results suggest that a strategy where the contactor plasma and the electron beam operate simultaneously might offer a pathway to perform beam experiments in the magnetosphere.

  18. Clean-in-Place and Reliability Testing of a Commercial 12.5 cm Annular Centrifugal Contactor at the INL

    SciTech Connect

    N. R. Mann; T. G. Garn; D. H. Meikrantz; J. D. Law; T. A. Todd

    2007-09-01

    The renewed interest in advancing nuclear energy has spawned the research of advanced technologies for recycling nuclear fuel. A significant portion of the advanced fuel cycle includes the recovery of selected actinides by solvent extraction methods utilizing centrifugal contactors. Although the use of centrifugal contactors for solvent extraction is widely known, their operation is not without challenges. Solutions generated from spent fuel dissolution contain unknown quantities of undissolved solids. A majority of these solids will be removed via various methods of filtration. However, smaller particles are expected to carry through to downstream solvent extraction processes and equipment. In addition, solids/precipitates brought about by mechanical or chemical upsets are another potential area of concern. During processing, particulate captured in the rotor assembly by high centrifugal forces eventually forms a cake-like structure on the inner wall introducing balance problems and negatively affecting phase separations. One of the features recently developed for larger engineering scale Annular Centrifugal Contactors (ACCs) is the Clean-In-Place (CIP) capability. Engineered spray nozzles were installed into the hollow central rotor shaft in all four quadrants of the rotor assembly. This arrangement allows for a very convenient and effective method of solids removal from within the rotor assembly.

  19. Clean-in-Place and Reliability Testing of a Commercial 12.5-cm Annular Centrifugal Contactor at the INL

    SciTech Connect

    N. R. Mann; T. G. Garn; D. H. Meikrantz; J. D. Law; T. A. Todd

    2007-09-01

    The renewed interest in advancing nuclear energy has spawned the research of advanced technologies for recycling nuclear fuel. A significant portion of the advanced fuel cycle includes the recovery of selected actinides by solvent extraction methods utilizing centrifugal contactors. Although the use of centrifugal contactors for solvent extraction is widely known, their operation is not without challenges. Solutions generated from spent fuel dissolution contain unknown quantities of undissolved solids. A majority of these solids will be removed via various methods of filtration. However, smaller particles are expected to carry through to downstream solvent extraction processes and equipment. In addition, solids/precipitates brought about by mechanical or chemical upsets are another potential area of concern. During processing, particulate captured in the rotor assembly by high centrifugal forces eventually forms a cake-like structure on the inner wall introducing balance problems and negatively affecting phase separations. One of the features recently developed for larger engineering scale Annular Centrifugal Contactors (ACCs) is the Clean-In-Place (CIP) capability. Engineered spray nozzles were installed into the hollow central rotor shaft in all four quadrants of the rotor assembly. This arrangement allows for a very convenient and effective method of solids removal from within the rotor assembly.

  20. Life Testing of the Hollow Cathode Plasma Contactor for the ProSEDS Mission

    NASA Technical Reports Server (NTRS)

    Vaughn, Jason A.; Schneider, Todd A.; Finckenor, Miria M.; Munafo, Paul M. (Technical Monitor)

    2001-01-01

    The Propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta 11 unmanned expendable booster. A 5-km conductive tether is attached to the Delta 11 second stage and collects current from the low Earth orbit (LEO) plasma. A hollow cathode plasma contactor emits the collected electrons from the Delta II, completing the electrical circuit with the ambient plasma. The current flowing through the tether generates thrust based on the Lorentz Force Law. The thrust will be generated opposite to the velocity vector, slowing down the spacecraft and causing it to de-orbit in approximately 14 days compared to the normal 6 months. A 10-km non-conductive tether is between the conductive tether and an endmass containing several scientific instruments. The ProSEDS mission lifetime was set at I day because most of the primary objectives can be met in that time. The extended ProSEDS mission will be for as many days as possible, until the Delta 11 second stage burns up or the tether is severed by a micrometeoroid or space debris particle. The Hollow Cathode Plasma Contactor (HCPC) unit has been designed for a 12-day mission. Because of the science requirements to measure the background ambient plasma, the HCPC must operate on a duty cycle. Later in the ProSEDS mission, the HCPC is operated in a manner to allow charging of the secondary battery. Due to the unusual operating requirements by the ProSEDS mission, a development unit of the HCPC was built for thorough testing. This developmental unit was tested for a simulated ProSEDS mission, with measurements of the ability to start and stop during the duty cycle. These tests also provided valuable data for the ProSEDS software requirements. Qualification tests of the HCPC flight hardware are also discussed.

  1. Evaluation of a New Remote Handling Design for High Throughput Annular Centrifugal Contactors

    SciTech Connect

    David H. Meikrantz; Troy G. Garn; Jack D. Law; Lawrence L. Macaluso

    2009-09-01

    Advanced designs of nuclear fuel recycling plants are expected to include more ambitious goals for aqueous based separations including; higher separations efficiency, high-level waste minimization, and a greater focus on continuous processes to minimize cost and footprint. Therefore, Annular Centrifugal Contactors (ACCs) are destined to play a more important role for such future processing schemes. Previous efforts defined and characterized the performance of commercial 5 cm and 12.5 cm single-stage ACCs in a “cold” environment. The next logical step, the design and evaluation of remote capable pilot scale ACCs in a “hot” or radioactive environment was reported earlier. This report includes the development of remote designs for ACCs that can process the large throughput rates needed in future nuclear fuel recycling plants. Novel designs were developed for the remote interconnection of contactor units, clean-in-place and drain connections, and a new solids removal collection chamber. A three stage, 12.5 cm diameter rotor module has been constructed and evaluated for operational function and remote handling in highly radioactive environments. This design is scalable to commercial CINC ACC models from V-05 to V-20 with total throughput rates ranging from 20 to 650 liters per minute. The V-05R three stage prototype was manufactured by the commercial vendor for ACCs in the U.S., CINC mfg. It employs three standard V-05 clean-in-place (CIP) units modified for remote service and replacement via new methods of connection for solution inlets, outlets, drain and CIP. Hydraulic testing and functional checks were successfully conducted and then the prototype was evaluated for remote handling and maintenance suitability. Removal and replacement of the center position V-05R ACC unit in the three stage prototype was demonstrated using an overhead rail mounted PaR manipulator. This evaluation confirmed the efficacy of this innovative design for interconnecting and cleaning

  2. Randomly Accountable

    ERIC Educational Resources Information Center

    Kane, Thomas J.; Staiger, Douglas O.; Geppert, Jeffrey

    2002-01-01

    The accountability debate tends to devolve into a battle between the pro-testing and anti-testing crowds. When it comes to the design of a school accountability system, the devil is truly in the details. A well-designed accountability plan may go a long way toward giving school personnel the kinds of signals they need to improve performance.…

  3. School Accountability.

    ERIC Educational Resources Information Center

    Evers, Williamson M., Ed.; Walberg, Herbert J., Ed.

    This book presents the perspectives of experts from the fields of history, economics, political science, and psychology on what is known about accountability, what still needs to be learned, what should be done right now, and what should be avoided in devising accountability systems. The common myths about accountability are dispelled and how it…

  4. Pit membrane structure is highly variable and accounts for a major resistance to water flow through tracheid pits in stems and roots of two boreal conifer species.

    PubMed

    Schulte, Paul J; Hacke, Uwe G; Schoonmaker, Amanda L

    2015-10-01

    The flow of xylem sap in conifers is strongly dependent on the presence of a low resistance path through bordered pits, particularly through the pores present in the margo of the pit membrane. A computational fluid dynamics approach was taken, solving the Navier-Stokes equation for models based on the geometry of pits observed in tracheids from stems and roots of Picea mariana (black spruce) and Picea glauca (white spruce). Model solutions demonstrate a close, inverse relationship between the total resistance of bordered pits and the total area of margo pores. Flow through the margo was dominated by a small number of the widest pores. Particularly for pits where the margo component of flow resistance was low relative to that of the torus, pore location near the inner edge of the margo allowed for greater flow than that occurring through similar-sized pores near the outer edge of the margo. Results indicate a surprisingly large variation in pit structure and flow characteristics. Nonetheless, pits in roots have lower resistance to flow than those in stems because the pits were wider and consisted of a margo with a larger area in pores.

  5. Preferential binding of positive nanoparticles on cell membranes is due to electrostatic interactions: A too simplistic explanation that does not take into account the nanoparticle protein corona.

    PubMed

    Forest, Valérie; Pourchez, Jérémie

    2017-01-01

    The internalization of nanoparticles by cells (and more broadly the nanoparticle/cell interaction) is a crucial issue both for biomedical applications (for the design of nanocarriers with enhanced cellular uptake to reach their intracellular therapeutic targets) and in a nanosafety context (as the internalized dose is one of the key factors in cytotoxicity). Many parameters can influence the nanoparticle/cell interaction, among them, the nanoparticle physico-chemical features, and especially the surface charge. It is generally admitted that positive nanoparticles are more uptaken by cells than neutral or negative nanoparticles. It is supposedly due to favorable electrostatic interactions with negatively charged cell membrane. However, this theory seems too simplistic as it does not consider a fundamental element: the nanoparticle protein corona. Indeed, once introduced in a biological medium nanoparticles adsorb proteins at their surface, forming a new interface defining the nanoparticle "biological identity". This adds a new level of complexity in the interactions with biological systems that cannot be any more limited to electrostatic binding. These interactions will then influence cell behavior. Based on a literature review and on an example of our own experience the parameters involved in the nanoparticle protein corona formation as well as in the nanoparticle/cell interactions are discussed.

  6. Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    1994-01-01

    A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.

  7. Surface Charging Controlling of the Chinese Space Station with Hollow Cathode Plasma Contactor

    NASA Astrophysics Data System (ADS)

    Jiang, Kai; Wang, Xianrong; Qin, Xiaogang; Yang, Shengsheng; Yang, Wei; Zhao, Chengxuan; Chen, Yifeng; Shi, Liang; Tang, Daotan; Xie, Kan

    2016-07-01

    A highly charged manned spacecraft threatens the life of an astronaut and extravehicular activity, which can be effectively reduced by controlling the spacecraft surface charging. In this article, the controlling of surface charging on Chinese Space Station (CSS) is investigated, and a method to reduce the negative potential to the CSS is the emission electron with a hollow cathode plasma contactor. The analysis is obtained that the high voltage (HV) solar array of the CSS collecting electron current can reach 4.5 A, which can be eliminated by emitting an adequate electron current on the CSS. The theoretical analysis and experimental results are addressed, when the minimum xenon flow rate of the hollow cathode is 4.0 sccm, the emission electron current can neutralize the collected electron current, which ensures that the potential of the CSS can be controlled in a range of less than 21 V, satisfied with safety voltage. The results can provide a significant reference value to define a flow rate to the potential controlling programme for CSS.

  8. Energy-efficient treatment of organic wastewater streams using a rotatable bioelectrochemical contactor (RBEC).

    PubMed

    Cheng, Ka Yu; Ho, Goen; Cord-Ruwisch, Ralf

    2012-12-01

    A membraneless bioelectrochemical system - rotatable bio-electrochemical contactor (RBEC) consists of an array of rotatable electrode disks was developed to convert the chemical energy from wastewater organics (acetate) directly into electricity. Each rotatable electrode disk had an upper-air exposing and a lower-water submerging halves. Intermittent rotation (180°) enabled each halve to alternately serve as anode and cathode. Removal of chemical oxygen demand (COD) was increased by 15% (from 0.79 to 0.91 kg COD m(-3) d(-1)) by allowing electron flow from the lower to the upper disk halves. Coupling with a potentiostat could alleviate cathodic limitation and increased COD removal to 1.32 kg COD m(-3) day(-1) (HRT 5h). About 40% of the COD removed was via current, indicating that the biofilm could use the lower half disk as electron acceptor. The RBEC removed COD more energy-efficiently than conventional activated sludge processes as active aeration is not required (0.47 vs. 0.7-2.0 kW h kg COD(-1)).

  9. Continuous treatment of coloured industry wastewater using immobilized Phanerochaete chrysosporium in a rotating biological contactor reactor.

    PubMed

    Pakshirajan, Kannan; Kheria, Sumeet

    2012-06-30

    Coloured industry wastewaters often contain dyes and other toxic ingredients, and, therefore, pose serious threat to the receiving environment. Among the available methods the eco-friendly biological method has gained maximum attention due to its many advantages over the traditional methods. In the present study, continuous biological treatment of coloured wastewater from a textile dyeing industry was investigated using the white rot fungus Phanerochaete chrysosporium in a rotating biological contactor (RBC) reactor. The raw wastewater was diluted with an equal volume of either distilled water or media containing glucose at varying concentrations to study its effect on the decolourization process. Results revealed that the wastewater could be decolourized to an extent of more than 64% when diluted with media containing glucose; and, a maximum decolourization efficiency of 83% was obtained with 10 g/l glucose concentration. COD removal efficiencies were also found to be consistent with the decolourization efficiencies of the wastewaters. Further, the results were correlated with the enzyme activities of manganese peroxidase (MnP) and lignin peroxidase (LiP) by the fungus, which were found to play some significant role in decolourization of the wastewater. Results of replacing the costly carbon source glucose in the decolourization media with the more cheap molasses, however, revealed very high COD removal efficiency, but low decolourization efficiency of the industry wastewater. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Experimental design and statistical analysis in Rotating Disc Contactor (RDC) column

    NASA Astrophysics Data System (ADS)

    Ismail, Wan Nurul Aiffah; Zakaria, Siti Aisyah; Noor, Nor Fashihah Mohd; Ariffin, Wan Nor Munirah

    2015-12-01

    The purpose of this paper is to examine the performance of the liquid-liquid extraction in Rotating Disc Contactor (RDC) Column that being used in industries. In this study, the performance of small diameter column RDC using the chemical system involving cumene/isobutryric asid/water are analyzed by the method of design of the experiments (DOE) and also Multiple Linear Regression (MLR). The DOE method are used to estimated the effect of four independent. Otherwise, by using Multiple Linear Regression (MLR) is to justify the relationship between the input variables and output variables and also to determine which variable are more influence for both output variable. The input variables for both method include rotor speed (Nr); ratio of flow (Fd); concentration of continuous inlet (Ccin); concentration of dispersed inlet (Cdin); interaction between Nr with Fd; interaction between Nr with Ccin; interaction Nr with Cdin. Meanwhile the output variables are concentration of continuous outlet (Ccout) and concentration of dispersed outlet (Cdout) on RDC column performance. By using this two method, we have two linear model represent two output of Ccout and Cdout for MLR. Lastly, the researcher want to determine which input variable that give more influence to output variable by using this two method. Based on the result, we obtained that rotor speed (Nr) more influence to dependent variable, Ccout and concentration of continuous inlet (Ccin) more influence to dependent variable, Cdout according the two method that was used.

  11. Hydraulic characteristics of an anoxic rotating biological contactor: influence of biofilm.

    PubMed

    Teixeira, P; Alves, M; Oliveira, R

    2001-10-01

    The hydraulic characteristics of an anoxic rotating biological contactor were studied under different flow rates. The experiments were carried out with the reactor clean (without biomass) and containing denitrifying biofilm (Alcaligenes denitrificans) covering the disks. Residence Time Distribution (RTD) experiments were performed by the stimulus-response technique using lithium chloride as tracer. Experiments without biomass revealed the existence of hydraulic dead volumes (around 40% for hydraulic residence time of 0.94 and 2 hours) that occur in corners, where stagnant eddies form. When in normal operation, with the disks covered by biofilm and with biogas production, these values decreased significantly. For hydraulic residence time (HRT) of 2 hours a minimum dead volume was observed, being appropriate to run the reactor under this condition, from the hydraulic viewpoint. The Dispersion number decreased with increasing HRT from 0.94 h on, for both types of experiment, without, and in the presence of biomass. For this HRT the dispersion number was maximal in both situations. A considerable diffusion of tracer into the biofilm was detected, being faster in the more hydrated biofilm, and Justifying the long tails observed in the RTD experimental curves.

  12. Rotating biological contactor reactor with biofilm promoting mats for treatment of benzene and xylene containing wastewater.

    PubMed

    Sarayu, K; Sandhya, S

    2012-12-01

    A novel rotating biological contactor (RBC) bioreactor immobilized with microorganisms was designed to remove volatile organic compounds (VOC), such as benzene and xylene from emissions, and its performance was investigated. Gas-phase VOCs stripped by air injection were 98 % removed in the RBC when the superficial air flow rate was 375 ml/h (1,193 and 1,226 mg/l of benzene and xylene, respectively). The maximum removal rate was observed to be 1,007 and 1,872 mg/m(3)/day for benzene and xylene, respectively. The concentration profile of benzene and xylene along the RBC was dependent on the air flow rate and the degree of microbial adaptation. Air flow rate and residence time were found to be the most important operational parameters for the RBC reactor. By manipulating these operational parameters, the removal efficiency and capacity of the bioreactor could be enhanced. The kinetic constant K (s) demonstrated a linear relationship that indicated the maximum removal of benzene and xylene in RBC reactor. The phylogenic profile shows the presence of bacterium like Pseudomonas sp., Bacillus sp., and Enterococcus sp., which belonged to the phylum Firmicutes, and Proteobacteria that were responsible for the 98 % organic removal in the RBC.

  13. Mass Transfer Testing of a 12.5-cm Rotor Centrifugal Contactor

    SciTech Connect

    D. H. Meikrantz; T. G. Garn; J. D. Law; N. R. Mann; T. A. Todd

    2008-09-01

    TRUEX mass transfer tests were performed using a single stage commercially available 12.5 cm centrifugal contactor and stable cerium (Ce) and europium (Eu). Test conditions included throughputs ranging from 2.5 to 15 Lpm and rotor speeds of 1750 and 2250 rpm. Ce and Eu extraction forward distribution coefficients ranged from 13 to 19. The first and second stage strip back distributions were 0.5 to 1.4 and .002 to .004, respectively, throughout the dynamic test conditions studied. Visual carryover of aqueous entrainment in all organic phase samples was estimated at < 0.1 % and organic carryover into all aqueous phase samples was about ten times less. Mass transfer efficiencies of = 98 % for both Ce and Eu in the extraction section were obtained over the entire range of test conditions. The first strip stage mass transfer efficiencies ranged from 75 to 93% trending higher with increasing throughput. Second stage mass transfer was greater than 99% in all cases. Increasing the rotor speed from 1750 to 2250 rpm had no significant effect on efficiency for all throughputs tested.

  14. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    SciTech Connect

    Howard S. Meyer

    2002-06-01

    A new project was initiated this quarter to develop gas/liquid membranes for natural gas upgrading. Efforts have concentrated on legal agreements, including alternative field sites. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.

  15. Impaired Lysosomal Integral Membrane Protein 2-dependent Peroxiredoxin 6 Delivery to Lamellar Bodies Accounts for Altered Alveolar Phospholipid Content in Adaptor Protein-3-deficient pearl Mice.

    PubMed

    Kook, Seunghyi; Wang, Ping; Young, Lisa R; Schwake, Michael; Saftig, Paul; Weng, Xialian; Meng, Ying; Neculai, Dante; Marks, Michael S; Gonzales, Linda; Beers, Michael F; Guttentag, Susan

    2016-04-15

    The Hermansky Pudlak syndromes (HPS) constitute a family of disorders characterized by oculocutaneous albinism and bleeding diathesis, often associated with lethal lung fibrosis. HPS results from mutations in genes of membrane trafficking complexes that facilitate delivery of cargo to lysosome-related organelles. Among the affected lysosome-related organelles are lamellar bodies (LB) within alveolar type 2 cells (AT2) in which surfactant components are assembled, modified, and stored. AT2 from HPS patients and mouse models of HPS exhibit enlarged LB with increased phospholipid content, but the mechanism underlying these defects is unknown. We now show that AT2 in the pearl mouse model of HPS type 2 lacking the adaptor protein 3 complex (AP-3) fails to accumulate the soluble enzyme peroxiredoxin 6 (PRDX6) in LB. This defect reflects impaired AP-3-dependent trafficking of PRDX6 to LB, because pearl mouse AT2 cells harbor a normal total PRDX6 content. AP-3-dependent targeting of PRDX6 to LB requires the transmembrane protein LIMP-2/SCARB2, a known AP-3-dependent cargo protein that functions as a carrier for lysosomal proteins in other cell types. Depletion of LB PRDX6 in AP-3- or LIMP-2/SCARB2-deficient mice correlates with phospholipid accumulation in lamellar bodies and with defective intraluminal degradation of LB disaturated phosphatidylcholine. Furthermore, AP-3-dependent LB targeting is facilitated by protein/protein interaction between LIMP-2/SCARB2 and PRDX6 in vitro and in vivo Our data provide the first evidence for an AP-3-dependent cargo protein required for the maturation of LB in AT2 and suggest that the loss of PRDX6 activity contributes to the pathogenic changes in LB phospholipid homeostasis found HPS2 patients.

  16. Bench-Scale Development of a Hybrid Membrane-Absorption CO{sub 2} Capture Process: Preliminary Cost Assessment

    SciTech Connect

    Freeman, Brice; Kniep, Jay; Pingjiao, Hao; Baker, Richard; Rochelle, Gary; Chen, Eric; Frailie, Peter; Ding, Junyuan; Zhang, Yue

    2014-03-31

    This report describes a study of capture costs for a hybrid membrane-absorption capture system based on Membrane Technology and Research, Inc. (MTR)’s low-pressure membrane contactors and the University of Texas at Austin’s 5 m piperazine (PZ) Advanced Flash Stripper (AFS; 5 m PZ AFS) based CO2 capture system. The report is submitted for NETL review, and may be superseded by a final topical report on this topic that will be submitted to satisfy the Task 2 report requirement of the current project (DE-FE0013118).

  17. Absorption of sparingly soluble gases by reactive media in self-aerated gas-liquid contactors: A scale-up procedure

    SciTech Connect

    Zundelevich, Y.

    1995-01-01

    Absorption of sparingly soluble gases, such as NO or O{sub 2}, is greatly enhanced if the latter react with the media. Among a dozen of reactive solvents for NO{sub x} abatement, aqueous acidic urea appears the most economically and environmentally attractive because urea is a cheap reagent and because products of reaction of urea with nitrous acid, formed in the liquid phase via absorption of NO and NO{sub 2}, are carbon dioxide and nitrogen, which can be directly released into the atmosphere. That makes urea process unique among other wet scrubbing processes that routinely produce secondary waste. Its full potential has never been realized, perhaps due to the lack of an efficient gas-liquid contactor to overcome low solubility of NO in aqueous solutions. LLNL has recently designed and built a bench scale gas-liquid contactor for nitric acid regeneration with oxygen. The contactor proved very effective in overcoming the problem of low solubility of oxygen converting back to nitric acid approximately 99% of nitrous acid formed at the cathode (which would otherwise convert to NO{sub x}). The bench scale contactor consists of a 12 inch diameter tank with self-inducting impeller/aerator of very high gas capacity. The aerator represents a 3.5 inch turbine mounted on a vertical shaft inside the draft tube equipped with a stator. During operation the lower half of the turbine induces liquid and the upper half induces gas from the draft tube. The new contactor offers two approaches to solving the NO{sub x} pollution problem. Where full recovery of nitric acid is desired, oxygen can be fed into the contactor to convert nitrous acid into nitric. This approach was demonstrated at LLNL. Alternately, in the proposed acidic urea process nitrous acid, as it forms from NO{sub x}, would be converted to nitrogen, water and carbon dioxide.

  18. Authentic Accountability

    ERIC Educational Resources Information Center

    Eckert, Eileen; Bell, Alexandra

    2004-01-01

    Current accountability policy that bases assessment on validity and reliability criteria in the positivist research tradition is counterproductive to serving adult learners and their communities. In this article, we outline a framework for accountability that allows for the emergence and demonstration of the full range of program outcomes and…

  19. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    SciTech Connect

    Howard S. Meyer

    2003-01-01

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues.

  20. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    SciTech Connect

    Howard S. Meyer

    2002-10-01

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. KPS and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues.

  1. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    SciTech Connect

    Howard S. Meyer

    2002-06-30

    Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50--70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.

  2. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    SciTech Connect

    Howard S. Meyer

    2003-04-01

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. KPS and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Potting and module materials testing were initiated. Preliminary design

  3. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    SciTech Connect

    Howard S. Meyer

    2002-06-01

    Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment has been initiated. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50--70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.

  4. Packed cage rotating biological contactor system for treatment of cyanide wastewater.

    PubMed

    Sirianuntapiboon, Suntud; Chuamkaew, Chollada

    2007-01-01

    The aim of this work was to study the efficiency of the packed cage rotating biological contactor (RBC) system with synthetic wastewater (SWW) containing 800 mg/l BOD(5) with various cyanide residue concentrations and hydraulic loading time. The results showed that cyanide had a negative effect to both the system's efficiency and bio-film quality. An increase in cyanide concentration led to a decrease in bio-film growth and the consequent reduction in the removal efficiency of the system. Also, the effluent suspended solids (SS) of the system was increased with increasing cyanide concentrations because the bio-film detached from the media due to the toxicity of the cyanide residue. The system showed the highest COD, BOD(5), TKN and cyanide removal efficiencies of 94.0 +/- 1.6%, 94.8 +/- 0.9%, 59.1 +/- 2.8% and 95.5 +/- 0.6%, respectively, with SWW containing 5 mg/l cyanide under HRT of 8 days, while they were only 88.8 +/- 0.7%, 89.5 +/- 0.5%, 40.3 +/- 1.1% and 93.60 +/- 0.09%, respectively, with SWW containing 40 mg/l cyanide. In addition, the effluent ammonia, nitrite and nitrate were increased with increases in cyanide concentration or loading. However, the system with SWW containing the highest cyanide concentration of 40 mg/l showed almost constant COD and BOD(5) removal efficiencies of 89% and 90%, even when the system was controlled under the lowest HRT of 8 h.

  5. Biofilm growth of Chlorella sorokiniana in a rotating biological contactor based photobioreactor.

    PubMed

    Blanken, W; Janssen, M; Cuaresma, M; Libor, Z; Bhaiji, T; Wijffels, R H

    2014-12-01

    Microalgae biofilms could be used as a production platform for microalgae biomass. In this study, a photobioreactor design based on a rotating biological contactor (RBC) was used as a production platform for microalgae biomass cultivated in biofilm. In the photobioreactor, referred to as Algadisk, microalgae grow in biofilm on vertical rotating disks partially submerged in a growth medium. The objective is to evaluate the potential of the Algadisk photobioreactor with respect to the effects of disk roughness, disk rotation speed and CO2 concentration. These objectives where evaluated in relationship to productivity, photosynthetic efficiency, and long-term cultivation stability in a lab-scale Algadisk system. Although the lab-scale Algadisk system is used, operation parameters evaluated are relevant for scale-up. Chlorella Sorokiniana was used as model microalgae. In the lab-scale Algadisk reactor, productivity of 20.1 ± 0.7 g per m(2) disk surface per day and a biomass yield on light of 0.9 ± 0.04 g dry weight biomass per mol photons were obtained. Different disk rotation speeds did demonstrate minimal effects on biofilm growth and on the diffusion of substrate into the biofilm. CO2 limitation, however, drastically reduced productivity to 2-4 g per m(2) disk surface per day. Productivity could be maintained over a period of 21 weeks without re-inoculation of the Algadisk. Productivity decreased under extreme conditions such as pH 9-10, temperature above 40°C, and with low CO2 concentrations. Maximal productivity, however, was promptly recovered when optimal cultivation conditions were reinstated. These results exhibit an apparent opportunity to employ the Algadisk photobioreactor at large scale for microalgae biomass production if diffusion does not limit the CO2 supply. © 2014 Wiley Periodicals, Inc.

  6. An electrically driven gas-liquid-liquid contactor for bioreactor and other applications

    SciTech Connect

    Tsouris, C.; Borole, A.P.; Kaufman, E.N.; DePaoli, D.W.

    1999-05-01

    An electrically driven gas-liquid-liquid bioreactor is described here, in which an aqueous medium containing a biocatalyst is introduced as a discontinuous phase into an organic-continuous liquid phase containing a substrate to be converted by the biocatalyst. A gas discontinuous phase, which may be needed to provide oxygen or a gaseous substrate to the biocatalyst, is also introduced into the bioreactor. In contrast to previous work on electrically driven contactors, it was found that the electroconvection generated by the electric field between parallel-plate electrodes may be employed to increase the volume fraction of the discontinuous gas phase in the bioreactor, providing the means for enhanced mass transfer. The electrically driven bioreactor was utilized for oil desulfurization experiments with Rhodococcus sp. IGTS8 bacteria as the biocatalyst. The organic phase used in the experiments was hexadecane containing dibenzothiophene, a model sulfur compound, that is oxidatively desulfurized to 2-hydroxybiphenyl (2-HBP) by the bacteria in the presence of air or oxygen. The gas volume fraction was increased by 60% by the application of a pulsed electric field, thus providing a means for increased transport of oxygen needed for oxidative desulfurization. The velocity of droplets and bubbles was measured by a phase Doppler velocimeter. The average rising velocity of bubbles was decreased from 13 to less than 3 cm/s and the average horizontal velocity was increased from 0 to 5 cm/s as the field strength was increased from 0 to 4 kV/cm. Desulfurization rates ranged from 1.0 to 5.50 mg of 2-HBP/g of dry cells/h. The desulfurization rate with aeration was doubled under the electric field as compared to the zero-field desulfurization under the same conditions.

  7. Membrane technology in microalgae cultivation and harvesting: a review.

    PubMed

    Bilad, M R; Arafat, Hassan A; Vankelecom, Ivo F J

    2014-11-15

    Membrane processes have long been applied in different stages of microalgae cultivation and processing. These processes include microfiltration, ultrafiltration, dialysis, forward osmosis, membrane contactors and membrane spargers. They are implemented in many combinations, both as a standalone and as a coupled system (in membrane biomass retention photobioreactors (BR-MPBRs) or membrane carbonation photobioreactors (C-MPBRs). To provide sufficient background on these applications, an overview of membrane materials and membrane processes of interest in microalgae cultivation and processing is provided in this work first. Afterwards, discussion about specific aspects of membrane applications in microbial cultivation and harvesting is provided, including membrane fouling. Many of the membrane processes were shown to be promising options in microalgae cultivation. Yet, significant process optimizations are still required when they are applied to enable microalgae biomass bulk production to become competitive as a raw material for biofuel production. Recent developments of the coupled systems (BR-MPBR and C-MPBR) bring significant promises to improve the volumetric productivity of a cultivation system and the efficiency of inorganic carbon capture, respectively.

  8. Evaluation of the Hydraulic Capacity and Mass Transfer Efficiency of the CSSX Process with the Optimized Solvent in a Single Stage of 5.5-cm-Diameter Centrifugal Contactor

    SciTech Connect

    Law, Jack Douglas; Tillotson, Richard Dean; Todd, Terry Allen

    2002-09-01

    The Caustic-Side Solvent Extraction (CSSX) process has been selected for the separation of cesium from Savannah River Site high-level waste. The solvent composition used in the CSSX process was recently optimized so that the solvent is no longer supersaturated with respect to the calixarene crown ether extractant. Hydraulic performance and mass transfer efficiency testing of a single stage of 5.5-cm ORNL-designed centrifugal contactor has been performed for the CSSX process with the optimized solvent. Maximum throughputs of the 5.5-cm centrifugal contactor, as a function of contactor rotor speed, have been measured for the extraction, scrub, strip, and wash sections of the CSSX flowsheet at the baseline organic/aqueous flow ratios (O/A) of the process, as well as at O/A’s 20% higher and 20% lower than the baseline. Maximum throughputs are comparable to the design throughput of the contactor, as well as with throughputs obtained previously in a 5-cm centrifugal contactor with the non-optimized CSSX solvent formulation. The 20% variation in O/A had minimal effect on contactor throughput. Additionally, mass transfer efficiencies have been determined for the extraction and strip sections of the flowsheet. Efficiencies were lower than the process goal of greater than or equal to 80%, ranging from 72 to 75% for the extraction section and from 36 to 60% in the strip section. Increasing the mixing intensity and/or the solution level in the mixing zone of the centrifugal contactor (residence time) could potentially increase efficiencies. Several methods are available to accomplish this including (1) increasing the size of the opening in the bottom of the rotor, resulting in a contactor which is partially pumping instead of fully pumping, (2) decreasing the number of vanes in the contactor, (3) increasing the vane height, or (4) adding vanes on the rotor and baffles on the housing of the contactor. The low efficiency results obtained stress the importance of proper design

  9. Evaluation of the Hydraulic Performance and Mass Transfer Efficiency of the CSSX Process with the Optimized Solvent in a Single Stage of 5.5-Cm Diameter Centrifugal Contactor

    SciTech Connect

    Law, J.D.; Tillotson, R.D.; Todd, T.A.

    2002-09-19

    The Caustic-Side Solvent Extraction (CSSX) process has been selected for the separation of cesium from Savannah River Site high-level waste. The solvent composition used in the CSSX process was recently optimized so that the solvent is no longer supersaturated with respect to the calixarene crown ether extractant. Hydraulic performance and mass transfer efficiency testing of a single stage of 5.5-cm ORNL-designed centrifugal contactor has been performed for the CSSX process with the optimized solvent. Maximum throughputs of the 5.5-cm centrifugal contactor, as a function of contactor rotor speed, have been measured for the extraction, scrub, strip, and wash sections of the CSSX flowsheet at the baseline organic/aqueous flow ratios (O/A) of the process, as well as at O/A's 20% higher and 20% lower than the baseline. Maximum throughputs are comparable to the design throughput of the contactor, as well as with throughputs obtained previously in a 5-cm centrifugal contactor with the non-optimized CSSX solvent formulation. The 20% variation in O/A had minimal effect on contactor throughput. Additionally, mass transfer efficiencies have been determined for the extraction and strip sections of the flowsheet. Efficiencies were lower than the process goal of greater than or equal to 80%, ranging from 72 to 75% for the extraction section and from 36 to 60% in the strip section. Increasing the mixing intensity and/or the solution level in the mixing zone of the centrifugal contactor (residence time) could potentially increase efficiencies. Several methods are available to accomplish this including (1) increasing the size of the opening in the bottom of the rotor, resulting in a contactor which is partially pumping instead of fully pumping, (2) decreasing the number of vanes in the contactor, (3) increasing the vane height, or (4) adding vanes on the rotor and baffles on the housing of the contactor. The low efficiency results obtained stress the importance of proper design of

  10. Centrifugal contactor with liquid mixing and flow control vanes and method of mixing liquids of different phases

    DOEpatents

    Jubin, Robert T.; Randolph, John D.

    1991-01-01

    The invention is directed to a centrifugal contactor for solvent extraction systems. The centrifugal contactor is provided with an annular vertically oriented mixing chamber between the rotor housing and the rotor for mixing process liquids such as the aqueous and organic phases of the solvent extraction process used for nuclear fuel reprocessing. A set of stationary helically disposed vanes carried by the housing is in the lower region of the mixing chamber at a location below the process-liquid inlets for the purpose of urging the liquids in an upward direction toward the inlets and enhancing the mixing of the liquids and mass transfer between the liquids. The upper region of the mixing vessel above the inlets for the process liquids is also provided with a set helically disposed vanes carried by the housing for urging the process liquids in a downward direction when the liquid flow rates through the inlets are relatively high and the liquids contact the vane set in the upper region. The use of these opposing vane sets in the mixing zone maintains the liquid in the mixing zone at suitable levels.

  11. Painless Accountability.

    ERIC Educational Resources Information Center

    Brown, R. W.; And Others

    The computerized Painless Accountability System is a performance objective system from which instructional programs are developed. Three main simplified behavioral response levels characterize this system: (1) cognitive, (2) psychomotor, and (3) affective domains. Each of these objectives are classified by one of 16 descriptors. The second major…

  12. Accounting Specialist.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Center on Education and Training for Employment.

    This publication identifies 20 subjects appropriate for use in a competency list for the occupation of accounting specialist, 1 of 12 occupations within the business/computer technologies cluster. Each unit consists of a number of competencies; a list of competency builders is provided for each competency. Titles of the 20 units are as follows:…

  13. Accountability Overboard

    ERIC Educational Resources Information Center

    Chieppo, Charles D.; Gass, James T.

    2009-01-01

    This article reports that special interest groups opposed to charter schools and high-stakes testing have hijacked Massachusetts's once-independent board of education and stand poised to water down the Massachusetts Comprehensive Assessment System (MCAS) tests and the accountability system they support. President Barack Obama and Massachusetts…

  14. Accountability Overboard

    ERIC Educational Resources Information Center

    Chieppo, Charles D.; Gass, James T.

    2009-01-01

    This article reports that special interest groups opposed to charter schools and high-stakes testing have hijacked Massachusetts's once-independent board of education and stand poised to water down the Massachusetts Comprehensive Assessment System (MCAS) tests and the accountability system they support. President Barack Obama and Massachusetts…

  15. CaBr{sub 2} hydrolysis for HBr production using a direct sparging contactor.

    SciTech Connect

    Yang, J.; Panchal, C. B.; Doctor, R. D.; Energy Systems

    2009-09-01

    The calcium-bromine cycle being investigated is a novel continuous hybrid cycle for hydrogen production employing both heat and electricity. Calcium bromide (CaBr{sub 2}) hydrolysis generates hydrogen bromide (HBr) which is electrolyzed to produce hydrogen. The CaBr{sub 2} hydrolysis at 1050 K (777 C) is endothermic with the heat of reaction {delta}G{sub T} = 181.5 KJ/mol (43.38 kcal/mol) and the Gibbs free energy change is positive at 99.6 kJ/mol (23.81 kcal/mol). What makes this hydrolysis reaction attractive is both its rate and that well over half the thermodynamic requirements for water-splitting heat of reaction of {delta}G{sub T} = 285.8 KJ/mol (68.32 kcal/mol) are supplied at this stage using heat rather than electricity. Molten-phase calcium bromide reactors may overcome the technical barriers associated with earlier hydrolysis approaches using supported solid-phase calcium bromide studied in the Japanese UT-3 cycle. Before constructing the experiment two design concepts were evaluated using COMSOL{trademark} multi-physics models; (1) the first involved sparging steam into a calcium-bromide melt, while (2) the second considered a 'spray-dryer' contactor spraying molten calcium bromide counter-currently to upward-flowing steam. A recent paper describes this work. These studies indicated that sparging steam into a calcium-bromide melt is more feasible than spraying molten calcium bromide droplets into steam. Hence, an experimental sparging hydrolysis reactor using a mullite tube (ID 70 mm) was constructed capable of holding 0.3-0.5 kg (1.5-2.5 x 10{sup -3} kg mol) CaBr{sub 2} forming a melt with a maximum 0.08 m (8 cm) depth. Sparging steam at a steam rate of 0.02 mol/mol of CaBr{sub 2} per minute (1.2-2.3 x 10{sup -5} kg/s), into this molten bath promptly yielded HBr in a stable operation that converted up to 25% of the calcium bromide. The kinetic constant derived from the experimental data was 2.17 x 10{sup -12} kmol s{sup -1} m{sup -2} MPa{sup -1} for

  16. Removal of diatrizoate with catalytically active membranes incorporating microbially produced palladium nanoparticles.

    PubMed

    Hennebel, Tom; De Corte, Simon; Vanhaecke, Lynn; Vanherck, Katrien; Forrez, Ilse; De Gusseme, Bart; Verhagen, Pieter; Verbeken, Kim; Van der Bruggen, Bart; Vankelecom, Ivo; Boon, Nico; Verstraete, Willy

    2010-03-01

    There is an increasing concern about the fate of iodinated contrast media (ICM) in the environment. Limited removal efficiencies of currently applied techniques such as advanced oxidation processes require more performant strategies. The aim of this study was to establish an innovative degradation process for diatrizoate, a highly recalcitrant ICM, by using biogenic Pd nanoparticles as free suspension or immobilized in polyvinylidene fluoride (PVDF) and polysulfone (PSf) membranes. As measured by HPLC-UV, the removal of 20mg L(-1) diatrizoate by a 10mg L(-1) Pd suspension was completed after 4h at a pH of 10. LC-MS analysis provided evidence for the sequential hydrodeiodination of diatrizoate. Pd did not lose its activity after incorporation in the PVDF and PSf matrix and the highest activity (k(cat)=30.0+/-0.4h(-1) L g(-1) Pd) was obtained with a casting solution of 10% PSf and 500mg L(-1) Pd. Subsequently, water containing 20mg L(-1) diatrizoate was treated in a membrane contactor, in which the water was supplied at one side of the membrane while hydrogen was provided at the other side. In a fed batch configuration, a removal efficiency of 77% after a time period of 48h was obtained. This work showed that membrane contactors with encapsulated biogenic nanoparticles can be instrumental for treatment of water contaminated with diatrizoate.

  17. An innovative membrane bioreactor for methane biohydroxylation.

    PubMed

    Pen, N; Soussan, L; Belleville, M-P; Sanchez, J; Charmette, C; Paolucci-Jeanjean, D

    2014-12-01

    In this study, a membrane bioreactor (MBR) was developed for efficient, safe microbial methane hydroxylation with Methylosinus trichosporium OB3b. This innovative MBR, which couples a bioreactor with two gas/liquid macroporous membrane contactors supplying the two gaseous substrates (methane and oxygen) was operated in fed-batch mode. The feasibility and the reproducibility of this new biohydroxylation process were first demonstrated. The mass transfer within this MBR was twice that observed in a batch reactor in similar conditions. The productivity reached with this MBR was 75±25mgmethanol(gdrycell)(-1)h(-1). Compared to the literature, this value is 35times higher than that obtained with the only other fed-batch membrane bioreactor reported, which was run with dense membranes, and is comparable to those obtained with bioreactors fed by bubble-spargers. However, in the latter case, an explosive gas mixture can be formed, a problem that is avoided with the MBR. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Removal of phenols from wastewater using liquid membranes in a microporous hollow-fiber-membrane extractor

    SciTech Connect

    Nanoti, A.; Ganguly, S.K.; Goswami, A.N.; Rawat, B.S.

    1997-10-01

    Phenols occur as toxic contaminants in effluent waters from industries such as oil refining, coke and coal processing, phenolic resin manufacture, and several other chemical and metallurgical operations. This paper reports experimental data on the removal of phenol from aqueous solutions using emulsion liquid membranes in a microporous hollow-fiber extractor. The hollow-fiber extractor appears to offer significant advantages over conventional liquid-liquid contactors for this separation because emulsion leakage and swell are practically eliminated even when treating high phenolic feeds. The overall mass-transfer coefficients are seen to be more strongly dependent on the phase flow rates among the parameters studied. The experimental mass-transfer coefficients have been predicted by a resistance-in-series model.

  19. Red cell membrane disorders.

    PubMed

    Narla, J; Mohandas, N

    2017-05-01

    Significant advances have been made in our understanding of the structural basis for altered cell function in various inherited red cell membrane disorders with reduced red cell survival and resulting hemolytic anemia. The current review summarizes these advances as they relate to defining the molecular and structural basis for disorders involving altered membrane structural organization (hereditary spherocytosis [HS] and hereditary elliptocytosis [HE]) and altered membrane transport function (hereditary overhydrated stomatocytosis and hereditary xerocytosis). Mutations in genes encoding membrane proteins that account for these distinct red cell phenotypes have been identified. These molecular insights have led to improved understanding of the structural basis for altered membrane function in these disorders. Weakening of vertical linkage between the lipid bilayer and spectrin-based membrane skeleton leads to membrane loss in HS. In contrast, weakening of lateral linkages among different skeletal proteins leads to membrane fragmentation and decreased surface area in HE. The degrees of membrane loss and resultant increases in cell sphericity determine the severity of anemia in these two disorders. Splenectomy leads to amelioration of anemia by increasing the circulatory red cell life span of spherocytic red cells that are normally sequestered by the spleen. Disordered membrane cation permeability and resultant increase or decrease in red cell volume account for altered cellular deformability of hereditary overhydrated stomatocytosis and hereditary xerocytosis, respectively. Importantly, splenectomy is not beneficial in these two membrane transport disorders and in fact contraindicated due to severe postsplenectomy thrombotic complications. © 2017 John Wiley & Sons Ltd.

  20. Use of the electrically driven emulsion-phase contactor for a biphasic liquid-liquid enzyme system

    SciTech Connect

    Scott, T.C.; Cosgrove, J.M.; DePaoli, D.W.

    1995-12-31

    An alternative approach to the operation of bioprocessing systems within non-aqueous environments would require the development of reaction systems that would provide effective interfacial contact between the biocatalyst, contained within an aqueous phase, and the organic phase containing the substrate. A biphasic liquid-liquid (BLL) reactor that provides for intimate liquid-liquid contact would be the most probable approach for this application. For the BLL reactions considered in this work, the overall effectiveness of the system will depend on both compatibility of the biocatalyst with the chemical species present and intrinsic reaction and interfacial transport phenomena typically involved with liquid-liquid operations. The focus of this article is to investigate the removal and oxidation of p-cresol dissolved in toluene by aqueous-phase horseradish peroxidase. Contacting of the liquid-liquid biphasic enzyme system is carried out in an advanced solvent extraction contacting device, the electrically driven emulsion-phase contactor (EPC).

  1. 3D printed modular centrifugal contactors and method for separating moieties using 3D printed optimized surfaces

    DOEpatents

    Wardle, Kent E.

    2017-08-29

    The present invention provides an annular centrifugal contactor, having a housing to receive a plurality of liquids; a rotor inside the housing; an annular mixing zone, with a plurality of fluid retention reservoirs; and an adjustable stem that can be raised to restrict the flow of a liquid into the rotor or lowered to increase the flow of liquid into the rotor. The invention also provides a method for transferring moieties from a first liquid to a second liquid, the method having the steps of combining the fluids in a housing whose interior has helically shaped first channels; subjecting the fluids to a spinning rotor to produce a mixture, whereby the channels simultaneously conduct the mixture downwardly and upwardly; and passing the mixture through the rotor to contact second channels, whereby the channels pump the second liquid through a first aperture while the first fluid exits a second aperture.

  2. Control of nitratation in an oxygen-limited autotrophic nitrification/denitrification rotating biological contactor through disc immersion level variation.

    PubMed

    Courtens, Emilie N P; Boon, Nico; De Clippeleir, Haydée; Berckmoes, Karla; Mosquera, Mariela; Seuntjens, Dries; Vlaeminck, Siegfried E

    2014-03-01

    With oxygen supply playing a crucial role in an oxygen-limited autotrophic nitrification/denitrification (OLAND) rotating biological contactor (RBC), its controlling factors were investigated in this study. Disc rotation speeds (1.8 and 3.6rpm) showed no influence on the process performance of a lab-scale RBC, although abiotic experiments showed a significant effect on the oxygenation capacity. Estimations of the biological oxygen uptake rate revealed that 85-89% of the oxygen was absorbed by the microorganisms during the air exposure of the discs. Indeed, increasing the disc immersion (50 to 75-80%) could significantly suppress undesired nitratation, on the short and long term. The presented results demonstrated that nitratation could be controlled by the immersion level and revealed that oxygen control in an OLAND RBC should be predominantly based on the atmospheric exposure percentage of the discs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Membranes for corrosive oxidations. Final CRADA report.

    SciTech Connect

    Snyder, S. W.; Energy Systems

    2010-02-01

    The objective of this project is to develop porous hydrophilic membranes that are highly resistant to oxidative and corrosive conditions and to deploy them for recovery and purification of high tonnage chemicals such as hydrogen peroxide and other oxychemicals. The research team patented a process for membrane-based separation of hydrogen peroxide (US Patent No. 5,662,878). The process is based on using a hydrophilic membrane to separate hydrogen peroxide from the organic working solution. To enable this process, a new method for producing hydrophilic membrane materials (Patent No.6,464,880) was reported. We investigated methods of producing these hydrophilic materials and evaluated separations performance in comparison to membrane stability. It was determined that at the required membrane flux, membrane stability was not sufficient to design a commercial process. This work was published (Hestekin et al., J. Membrane Science 2006). To meet the performance needs of the process, we developed a membrane contactor method to extract the hydrogen peroxide, then we surveyed several commercial and pre-commercial membrane materials. We identified pre-commercial hydrophilic membranes with the required selectivity, flux, and stability to meet the needs of the process. In addition, we invented a novel reaction/separations format that greatly increases the performance of the process. To test the performance of the membranes and the new formats we procured and integrated reactor/membrane separations unit that enables controlled mixing, flow, temperature control, pressure control, and sampling. The results were used to file a US non-provisional patent application (ANL-INV 03-12). Hydrogen peroxide is widely used in pulp and paper applications, environmental treatment, and other industries. Virtually all hydrogen peroxide production is now based on a process featuring catalytic hydrogenation followed by auto-oxidation of suitable organic carrier molecules. This process has several

  4. International Space Station (ISS) Plasma Contactor Unit (PCU) Utilization Plan Assessment Update

    NASA Technical Reports Server (NTRS)

    Hernandez-Pellerano, Amri; Iannello, Christopher J.; Garrett, Henry B.; Ging, Andrew T.; Katz, Ira; Keith, R. Lloyd; Minow, Joseph I.; Willis, Emily M.; Schneider, Todd A.; Whittlesey, Edward J.; Wollack, Edward J.; Wright, Kenneth H.

    2014-01-01

    The International Space Station (ISS) vehicle undergoes spacecraft charging as it interacts with Earth's ionosphere and magnetic field. The interaction can result in a large potential difference developing between the ISS metal chassis and the local ionosphere plasma environment. If an astronaut conducting extravehicular activities (EVA) is exposed to the potential difference, then a possible electrical shock hazard arises. The control of this hazard was addressed by a number of documents within the ISS Program (ISSP) including Catastrophic Safety Hazard for Astronauts on EVA (ISS-EVA-312-4A_revE). The safety hazard identified the risk for an astronaut to experience an electrical shock in the event an arc was generated on an extravehicular mobility unit (EMU) surface. A catastrophic safety hazard, by the ISS requirements, necessitates mitigation by a two-fault tolerant system of hazard controls. Traditionally, the plasma contactor units (PCUs) on the ISS have been used to limit the charging and serve as a "ground strap" between the ISS structure and the surrounding ionospheric plasma. In 2009, a previous NASA Engineering and Safety Center (NESC) team evaluated the PCU utilization plan (NESC Request #07-054-E) with the objective to assess whether leaving PCUs off during non-EVA time periods presented risk to the ISS through assembly completion. For this study, in situ measurements of ISS charging, covering the installation of three of the four photovoltaic arrays, and laboratory testing results provided key data to underpin the assessment. The conclusion stated, "there appears to be no significant risk of damage to critical equipment nor excessive ISS thermal coating damage as a result of eliminating PCU operations during non- EVA times." In 2013, the ISSP was presented with recommendations from Boeing Space Environments for the "Conditional" Marginalization of Plasma Hazard. These recommendations include a plan that would keep the PCUs off during EVAs when the

  5. Evaluation of high-efficiency gas-liquid contactors for natural gas processing. Second semiannual technical progress report, April 1, 1993--September 30, 1993

    SciTech Connect

    Not Available

    1993-12-01

    The objective of this proposed program is to evaluate the potential of rotating gas-liquid contactors for natural gas processing by expanding the currently available database. This expansion will focus on application of this technology to environments representative of those typically encountered in natural gas processing plants. Operational and reliability concerns will be addressed while generating pertinent engineering data relating to the mass-transfer process. Work to be performed this reporting period are: complete all negotiations and processing of agreements; complete assembly, modifications, shakedown, and conduct fluid dynamic studies using the plastic rotary contactor unit; confirmation of project test matrix; and locate, and transport an amine plant and dehydration plant. Accomplishment for this period are presented.

  6. Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent

    SciTech Connect

    Herman, D. T.; Duignan, M. R.; Williams, M. R.; Peters, T. B.; Poirier, M. R.; Fondeur, F. F.

    2013-07-31

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05 M) concentration of the MaxCalix as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. Stage efficiency and mass distribution ratios were determined by measuring Cs concentration in the aqueous and organic phases during single contactor testing. The nominal cesium distribution ratio, D(Cs) measured for extraction ranged from 37-60. The data showed greater than 96% stage efficiency for extraction. No significant differences were noted for operations at 4, 8 or 12 gpm aqueous salt simulant feed flow rates. The first scrub test (contact with weak caustic solution) yielded average scrub D(Cs) values of 3.3 to 5.2 and the second scrub test produced an average value of 1.8 to 2.3. For stripping behavior, the “first stage” D Cs) values ranged from 0.04 to 0.08. The efficiency of the low flow (0.27 gpm aqueous) was calculated to be 82.7%. The Spreadsheet

  7. Hybrid Membrane/Absorption Process for Post-combustion CO2 Capture

    SciTech Connect

    Li, Shiguang; Shou, S.; Pyrzynski, Travis; Makkuni, Ajay; Meyer, Howard

    2013-12-31

    This report summarizes scientific/technical progress made for bench-scale membrane contactor technology for post-combustion CO2 capture from DOE Contract No. DE-FE-0004787. Budget Period 1 (BP1) membrane absorber, Budget Period 2 (BP2) membrane desorber and Budget Period 3 (BP3) integrated system and field testing studies have been completed successfully and met or exceeded the technical targets (≥ 90% CO2 removal and CO2 purity of 97% in one membrane stage). Significant breakthroughs are summarized below: BP1 research: The feasibility of utilizing the poly (ether ether ketone), PEEK, based hollow fiber contractor (HFC) in combination with chemical solvents to separate and capture at least 90% of the CO2 from simulated flue gases has been successfully established. Excellent progress has been made as we have achieved the BP1 goal: ≥ 1,000 membrane intrinsic CO2 permeance, ≥ 90% CO2 removal in one stage, ≤ 2 psi gas side pressure drop, and ≥ 1 (sec)-1 mass transfer coefficient. Initial test results also show that the CO2 capture performance, using activated Methyl Diethanol Amine (aMDEA) solvent, was not affected by flue gas contaminants O2 (~3%), NO2 (66 ppmv), and SO2 (145 ppmv). BP2 research: The feasibility of utilizing the PEEK HFC for CO2-loaded solvent regeneration has been successfully established High CO2 stripping flux, one order of magnitude higher than CO2 absorption flux, have been achieved. Refined economic evaluation based on BP1 membrane absorber and BP2 membrane desorber laboratory test data indicate that the CO2 capture costs are 36% lower than DOE’s benchmark amine absorption technology. BP3 research: A bench-scale system utilizing a membrane absorber and desorber was integrated into a continuous CO2 capture process using contactors containing 10 to 20 ft2 of membrane area. The integrated process operation was stable through a 100-hour laboratory test, utilizing a simulated flue gas stream. Greater than 90% CO2 capture combined with 97

  8. Contactor Energy Requirements for Capturing CO2 From ambient air using NaOH determined in a pilot-scale prototype system

    NASA Astrophysics Data System (ADS)

    Stolaroff, J. K.; Keith, D.; Lowry, G.

    2005-12-01

    Systems for capturing CO2 from ambient air for sequestration have recently been proposed (e.g. Dubey et al., 2002; Zeman and Lackner, 2004; Keith et al., 2004). Capture from ambient air has a number of structural advantages over capture from point sources; in particular it makes possible future emissions scenarios with negative net CO2 emissions. The systems suggested use either a Ca(OH)2 or NaOH solution to capture CO2 and then regenerate the solution in a chemical loop. The energy requirements of such a system, however, have been hotly disputed (Herzog, 2003). The energy requirements and effectiveness of the chemical regeneration are well established as they are practiced on a large scale in the industrial kraft process used in pulp and paper production, but the energy and land use requirements of a contactor for this system are uncertain as this component of the system is not implemented industrially. In this research, we address the most controversial component of the system, the contactor, which extracts CO2 from air into solution. A prototype contactor with a spray tower design is constructed (1m by 6m), and CO2 absorption by a NaOH solution spray (5 l/min) is measured. The CO2 absorption efficiency and energy requirements per unit CO2 absorbed are calculated. The energy requirements of the contactor are found to be on the order of 10-40 kJ/mol-CO2, which is small compared to the energy of combustion of fossil fuels, and compared with the energy required for the regeneration steps. Thus, a NaOH-based spray tower design can serve as an energy-efficient contactor for capturing CO2 from ambient air. Dubey, M. K., Ziock, H., Rueff, G., Elliott, S., and Smith, W. S. (2002). ``Extraction of carbon dioxide from the atmosphere through engineered chemical sinkage''. ACS -- Division of Fuel Chemistry Reprints, 47(1):81--84. Herzog, H. (2003). Assessing the feasibility of capturing co2 from the air. Technical report, MIT Laboratory for Energy and the Environment. Keith

  9. Design and development of a self-regenerative contained-liquid membrane process for combined SO{sub x} and NO{sub x} removal. Final report

    SciTech Connect

    Varanasi, S.; LeBlanc, S.E.

    1992-11-01

    The lack of an efficient, cost effective process for the removal of sulfur compounds from gas streams (either gasified coal or flue gases resulting from coal combustion) is a major obstacle to the economic utilization of high sulfur Ohio coal. The most economically favorable processes for the desulfurization of flue gases are the regenerable processes as opposed to the `throwaway` processes. In addition, recovery of sulfur from these gases in the form of elemental sulfur or H{sub 2}SO{sub 4} does seem to be an essential step in the economic utilization of high sulfur coal. n light of these observations, a recently proposed FGD process which regenerates the scrubbing liquor ``in-situ`` as well as recovering a concentrated S0{sub 2} stream for use in sulfuric acid production, is quite promising. Conventional processes, presently in operation, employ large packed tower scrubbers for S0{sub 2} absorption which results in very high capital expenditures and operating costs. Recent developments in membrane technology can now provide us with an alternative to these large packed towers for stack gas cleanup. In this research we have investigated the use of novel membrane contactors for replacing more conventional packed absorbers. Contained-liquid membranes, exploiting carrier mediated transpose, enable the scrubbing liquid to be regenerated ``in-site,`` in a single process unit. Microporous single-ply polymeric membranes have recently been used in gas-liquid and liquid-liquid contactors. These membranes are fashioned into a tubular shape (i.e. long, thin fibers) for use in mass transfer contactors.

  10. Flow and fouling in membrane filters: Effects of membrane morphology

    NASA Astrophysics Data System (ADS)

    Sanaei, Pejman; Cummings, Linda J.

    2015-11-01

    Membrane filters are widely-used in microfiltration applications. Many types of filter membranes are produced commercially, for different filtration applications, but broadly speaking the requirements are to achieve fine control of separation, with low power consumption. The answer to this problem might seem obvious: select the membrane with the largest pore size and void fraction consistent with the separation requirements. However, membrane fouling (an inevitable consequence of successful filtration) is a complicated process, which depends on many parameters other than membrane pore size and void fraction; and which itself greatly affects the filtration process and membrane functionality. In this work we formulate mathematical models that can (i) account for the membrane internal morphology (internal structure, pore size & shape, etc.); (ii) fouling of membranes with specific morphology; and (iii) make some predictions as to what type of membrane morphology might offer optimum filtration performance.

  11. Membrane stabilizer

    DOEpatents

    Mingenbach, William A.

    1988-01-01

    A device is provided for stabilizing a flexible membrane secured within a frame, wherein a plurality of elongated arms are disposed radially from a central hub which penetrates the membrane, said arms imposing alternately against opposite sides of the membrane, thus warping and tensioning the membrane into a condition of improved stability. The membrane may be an opaque or translucent sheet or other material.

  12. Oxygen-limited autotrophic nitrification-denitrification (OLAND) in a rotating biological contactor treating high-salinity wastewater.

    PubMed

    Windey, Kim; De Bo, Inge; Verstraete, Willy

    2005-11-01

    A lab-scale rotating biological contactor (RBC) reactor operated under OLAND conditions was slowly adapted during 178 days to increasing salt concentrations going up to 30 g NaCl L(-1). The reactor performed well during this experimental period. However, the removal capacity of the reactor was lower under high-salinity conditions. A removal efficiency of 84% was achieved at a N loading rate of 725 mg N L(-1) d(-1) and a salt concentration of 30 g L(-1). The effect of salt shock loading and adaptation to 30 g NaCl L(-1) on the specific nitritation and anammox activity of the biomass was investigated in short-term batch experiments. A salt shock loading of 30 g L(-1) caused a 43% decrease in specific nitritation activity and 96% loss of specific anammox activity compared to reference biomass (not exposed to salt). The salt-adapted biomass (3-4 weeks) showed a specific nitritation activity that was 23% lower, and a specific anammox activity that was 58% lower, compared to the reference biomass. Overall, these results demonstrate that the OLAND process can have the potential to treat ammonium-rich brines after adaptation to high salinity.

  13. Oxygen-limited nitrogen removal in a lab-scale rotating biological contactor treating an ammonium-rich wastewater.

    PubMed

    Pynaert, K; Wyffels, S; Sprengers, R; Boeckx, P; Van Cleemput, O; Verstraete, W

    2002-01-01

    A lab-scale Rotating Biological Contactor (RBC) was operated with the purpose of oxygen-limited (autotrophic) nitrification-denitrification of an ammonium-rich synthetic wastewater without Chemical Oxygen Demand (COD). Based on the field observations that RBCs receiving anaerobic effluents come to anoxic ammonium removal, the RBC was inoculated with methanogenic sludge. Some 100 days after the addition of the anaerobic sludge to the reactor as a possible means of a rapid initiation of the nitrogen (N) removal process, a maximum ammonium removal of 1,550 mg N m(-2) d(-1) was achieved. Batch tests with 15N labeled ammonium and nitrite indicated that a large part of that N was removed via oxygen-limited oxidation of ammonium with nitrite as the electron acceptor. The other part was removed via conventional denitrification, presumably with COD released from lysis of cells. Species identification of the most abundant microorganisms revealed that Nitrosomonas spp. were the dominant ammonium-oxidizers in the sludge. Thus far, the molecular characterization of the sludge could not show the presence of Planctomycetes among the most dominant species. Overall this experiment confirms the property of the RBC system to remove ammonium to nitrogen gas without the use of heterotrophic carbon source.

  14. Application of annular centrifugal contactors in the hot test of the improved total partitioning process for high level liquid waste.

    PubMed

    Duan, Wuhua; Chen, Jing; Wang, Jianchen; Wang, Shuwei; Feng, Xiaogui; Wang, Xinghai; Li, Shaowei; Xu, Chao

    2014-08-15

    High level liquid waste (HLLW) produced from the reprocessing of the spent nuclear fuel still contains moderate amounts of uranium, transuranium (TRU) actinides, (90)Sr, (137)Cs, etc., and thus constitutes a permanent hazard to the environment. The partitioning and transmutation (P&T) strategy has increasingly attracted interest for the safe treatment and disposal of HLLW, in which the partitioning of HLLW is one of the critical technical issues. An improved total partitioning process, including a TRPO (tri-alkylphosphine oxide) process for the removal of actinides, a CESE (crown ether strontium extraction) process for the removal of Sr, and a CECE (calixcrown ether cesium extraction) process for the removal of Cs, has been developed to treat Chinese HLLW. A 160-hour hot test of the improved total partitioning process was carried out using 72-stage 10-mm-dia annular centrifugal contactors (ACCs) and genuine HLLW. The hot test results showed that the average DFs of total α activity, Sr and Cs were 3.57 × 10(3), 2.25 × 10(4) and 1.68 × 10(4) after the hot test reached equilibrium, respectively. During the hot test, 72-stage 10-mm-dia ACCs worked stable, continuously with no stage failing or interruption of the operation.

  15. Biological waste gas treatment with a modified rotating biological contactor. Iota. Control of biofilm growth and long-term performance.

    PubMed

    Vinage, I; von Rohr, P Rudolf

    2003-11-01

    In this work, we introduce a modified rotating biological contactor (RBC) system and demonstrate its feasibility by applying the newly devised process to the biological treatment of artificial waste gas. In the proposed system, the waste gas is introduced to the bioreactor in the spacings between the rotating discs through a hollow shaft, thus allowing for intimate gas-liquid contact. A 91-l modified RBC containing 20 biofilm support discs 40 cm in diameter was used in the experiments. Toluene was used as the model pollutant, and the system was operated under standard operating conditions for more than one year in order to investigate its long-term performance and assess its ability to control the growth of the biofilm. It was demonstrated that the proposed system allows to efficiently control the growth of the biofilm, thus overcoming the clogging problem inherent in most conventional methods for the biological treatment of waste gas. Moreover, the system was shown to exhibit stationary long-term performance for a period of more than one year, hence indicating its feasibility for industrial application.

  16. Biological nitrogen removal from landfill leachate by deammonification assisted by heterotrophic denitrification in a rotating biological contactor (RBC).

    PubMed

    Cema, G; Wiszniowski, J; Zabczyński, S; Zabłocka-Godlewska, E; Raszka, A; Surmacz-Górska, J

    2007-01-01

    Due to negative environmental effects of nitrogen discharge to recipients and increasingly stringent effluent standards, effective nitrogen removal is necessity. Biological methods are the simplest and cheapest way to treat wastewater; however, it may become an extremely expensive option when high influent nitrogen concentrations are measured and there is a lack of biodegradable organic carbon. Therefore, there is a great need to find new solutions and improve existing technologies. The deammonification is an excellent example of such a new process that requires considerably low amounts of organic carbon and oxygen in comparison to conventional nitrification/denitrification. The main objective of presented research was to investigate an Anammox process accompanied with autotrophic nitrification and heterotrophic denitrification in one rotating biological contactor (RBC). During the research period, it was possible to carry out the Anammox process in low temperature below 20 'C. Additionally, it was found that the process is insensitive to high nitrite concentration in the reactor, up to 100 g NO2-N m(-3), resulting only in a temporary decrease in removal rates. Furthermore, analysis of data indicated that the Stover-Kincannon model can be used for the description of ammonium and nitrite removal processes.

  17. Decolorization of bleach plant effluent by mucoralean and white-rot fungi in a rotating biological contactor reactor.

    PubMed

    Driessel, B V; Christov, L

    2001-01-01

    Bleach plant effluents from the pulp and paper industry generated during bleaching with chlorine-containing chemicals are highly colored and also partly toxic due to the presence of chloro-organics, hence the need for pretreatment prior to discharge. In a rotating biological contactor (RBC) reactor effluent decolorization was studied using Coriolus versicolor, a white-rot fungus and Rhizomucor pusillus strain RM7, a mucoralean fungus. Decolorization by both fungi was directly proportional to initial color intensities. It was found that the extent of decolorization was not adversely affected by color intensity, except at the lowest level tested. It was shown that decolorization of 53 to 73% could be attained using a hydraulic retention time of 23 h. With R. pusillus, 55% of AOX were removed compared to 40% by C. versicolor. Fungal treatment with both R. pusillus and C. versicolor rendered the effluent essentially nontoxic. Addition of glucose to decolorization media stimulated color removal by C. versicolor, but not with R. pusillus. Ligninolytic enzymes (manganese peroxidase and laccase) were only detected in effluent treated by C. versicolor. It seems that there are definite differences in the decoloring mechanisms between the white-rot fungus (adsorption + biodegradation) and the mucoralean fungus (adsorption). This aspect needs to be investigated in greater detail to verify the mode responsible for the decolorization activity in both types of fungi.

  18. Low-ammonia niche of ammonia-oxidizing archaea in rotating biological contactors of a municipal wastewater treatment plant

    PubMed Central

    Sauder, Laura A; Peterse, Francien; Schouten, Stefan; Neufeld, Josh D

    2012-01-01

    The first step of nitrification is catalysed by both ammonia-oxidizing bacteria (AOB) and archaea (AOA), but physicochemical controls on the relative abundance and function of these two groups are not yet fully understood, especially in freshwater environments. This study investigated ammonia-oxidizing populations in nitrifying rotating biological contactors (RBCs) from a municipal wastewater treatment plant. Individual RBC stages are arranged in series, with nitrification at each stage creating an ammonia gradient along the flowpath. This RBC system provides a valuable experimental system for testing the hypothesis that ammonia concentration determines the relative abundance of AOA and AOB. The results demonstrate that AOA increased as ammonium decreased across the RBC flowpath, as indicated by qPCR for thaumarchaeal amoA and 16S rRNA genes, and core lipid (CL) and intact polar lipid (IPL) crenarchaeol abundances. Overall, there was a negative logarithmic relationship (R2 = 0.51) between ammonium concentration and the relative abundance of AOA amoA genes. A single AOA population was detected in the RBC biofilms; this phylotype shared low amoA and 16S rRNA gene homology with existing AOA cultures and enrichments. These results provide evidence that ammonia availability influences the relative abundances of AOA and AOB, and that AOA are abundant in some municipal wastewater treatment systems. PMID:22639927

  19. Landfill leachate treatment using a rotating biological contactor and an upward-flow anaerobic sludge bed reactor

    SciTech Connect

    Castillo, E. Vergara, M.; Moreno, Y.

    2007-07-01

    This paper describes the feasibility of an aerobic system (rotating biological contactor, RBC) and a biological anaerobic system (upward-flow anaerobic sludge bed reactor) at small scale for the treatment of a landfill leachate. In the first phase of the aerobic system study, a cyclic-batch RBC system was used to select perforated acetate discs among three different acetate disc configurations. These discs were chosen on the basis of high COD removal (65%) and biological stability. In the second phase, the RBC system (using four stages) was operated continuously at different hydraulic retention times (HRT), at different rotational speeds, and with varying organic concentrations of the influent leachate (2500-9000 mg L{sup -1}). Forty percent of the total surface area of each perforated disc was submerged in the leachate. A COD removal of about 52% was obtained at an HRT of 24 h and a rotational speed of 6 rpm. For the anaerobic system, the reactor was evaluated with a volumetric organic load of 3273 g-COD m{sup -3} day{sup -1} at an HRT of 54, 44, 39, 24 and 17 h. At these conditions, the system reached COD removal efficiencies of 62%, 61%, 59%, 44% and 24%, respectively.

  20. Biodegradation and detoxification potential of rotating biological contactor (RBC) with Irpex lacteus for remediation of dye-containing wastewater.

    PubMed

    Malachova, Katerina; Rybkova, Zuzana; Sezimova, Hana; Cerven, Jiri; Novotny, Cenek

    2013-12-01

    Use of fungal organisms in rotating biological contactors (RBC) for bioremediation of liquid industrial wastes has so far been limited in spite of their significant biodegradation potential. The purpose was to investigate the power of RBC using Irpex lacteus for decolorization and detoxification of industrial dyes and dyeing textile liquors. Recalcitrant dye Methylene Blue (150 mg L(-1)) was decolorized within 70 days, its mutagenicity removed, and the biological toxicity decreased more than 10-fold. I. lacteus biofilm in the RBC completely decolorized within 26 and 47 days dyeing liquors containing disperse or reactive dyes adjusted to pH4.5 and 5-fold diluted with the growth medium, respectively. Their respective biological toxicity values were reduced 10- to 10(4)-fold in dependence of the test used. A battery of toxicity tests comprising Vibrio fisheri, Lemna minor and Sinapis alba was efficient to monitor the toxicity of textile dyes and wastewaters. Strong decolorization and detoxification power of RBC using I. lacteus biofilms was demonstrated.

  1. Rejuvenation of Spent Media via Supported Emulsion Liquid Membranes

    NASA Technical Reports Server (NTRS)

    Wiencek, John M.

    2002-01-01

    The overall goal of this project is to maximize the reuseability of spent fermentation media. Supported emulsion liquid membrane separation, a highly efficient extraction technique, is used to remove inhibitory byproducts during fermentation; thus, improving the yield while reducing the need for fresh water. The key objectives of this study are: Develop an emulsion liquid membrane system targeting low molecular weight organic acids which has minimal toxicity on a variety of microbial systems; Conduct mass transfer studies to allow proper modeling and design of a supported emulsion liquid membrane system; Investigate the effect of gravity on emulsion coalescence within the membrane unit; Access the effect of water re-use on fermentation yields in a model microbial system; Develop a perfusion-type fermentor utilizing a supported emulsion liquid membrane system to control inhibitory fermentation byproducts; Work for the coming year will focus on the determination of toxicity of various solvents, selection of the emulsifying agents, as well as characterizing the mass transfer of hollow-fiber contactors.

  2. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    SciTech Connect

    Howard S. Meyer

    2003-07-01

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Design and cost estimation for this new site are underway. Potting

  3. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    SciTech Connect

    Howard S. Meyer

    2003-10-01

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Design and cost estimation for this new site are underway. A Haz

  4. The plasma properties and electron emission characteristics of near-zero differential resistance of hollow cathode-based plasma contactors with a discharge chamber

    SciTech Connect

    Xie, Kan; Farnell, Casey C.; Williams, John D.

    2014-08-15

    The formation of electron emission-bias voltage (I-V) characteristics of near-zero differential resistance in the cathodic plasma contactor for bare electrodynamic tether applications, based on a hollow cathode embedded in a ring-cusp ionization stage, is studied. The existence of such an I-V regime is important to achieve low impedance performance without being affected by the space plasma properties for a cathodic plasma contactor. Experimental data on the plasma structure and properties downstream from the ionization stage are presented as functions of the xenon flow rate and the electron emission current. The electrons were emitted from the cathode to the cylindrical vacuum chamber wall (r = 0.9 m) under ≈10{sup −5 }Torr of vacuum pressure. The ring-cusp configuration selected for the plasma contactor created a 125-Gauss axial field near the cathode orifice, along with a large-volume 50-Gauss magnitude pocket in the stage. A baseline ion energy cost of ≈300 eV/ion was measured in the ionization stage when no electrons were emitted to the vacuum chamber wall. In addition, the anode fall growth limited the maximum propellant unitization to below ≈75% in the discharge loss curves for this ion stage. Detailed measurements on the plasma properties were carried out for the no-electron emission and 3 A emission conditions. The experimental data are compared with 1-D models, and the effectiveness of the model is discussed. The four key issues that played important roles in the process of building the near-zero different resistance I-V regime are: a significant amount of ionization by the emission electrons, a decrease in the number of reflected electrons in the plume, the electron-temperature increment, and low initial ion energy at the source outlet.

  5. Evaluation of high-efficiency gas-liquid contactors for natural gas processing. Semi-annual report, October 1993--March 1994

    SciTech Connect

    Not Available

    1994-05-01

    The objective of this proposed program is to evaluate the potential of rotating gas-liquid contactors for natural gas processing by expanding the currently available database. This expansion will focus on application of this technology to environments representative of those typically encountered in natural gas processing plants. Operational and reliability concerns will be addressed while generating pertinent engineering data relating to the mass-transfer process. Accomplishments for this period are described for Task 6 -- Fluid Dynamic Studies and Task 7 -- Mass Transfer Coefficient Studies.

  6. Evaluation of high-efficiency gas-liquid contactors for natural gas processing. Semi-annual report, April--September 1995

    SciTech Connect

    1995-11-01

    The objective of this proposed program is to ensure reliable supply of high-quality natural gas by reducing the cost of treating subquality natural gas containing H{sub 2}O, CO{sub 2}, H{sub 2}S and/or trace quantities of other gaseous impurities by applying high-efficiency rotating and structured packing gas liquid contactors. Work accomplished during this reporting period are discussed for the following tasks: Task 2, field experimental site seletion; Task 3, field experimental skid unit design and preliminary economic evaluations; and Task 6, fluid dynamic studies.

  7. Accounting Fundamentals for Non-Accountants

    EPA Pesticide Factsheets

    The purpose of this module is to provide an introduction and overview of accounting fundamentals for non-accountants. The module also covers important topics such as communication, internal controls, documentation and recordkeeping.

  8. Membrane stabilizer

    DOEpatents

    Mingenbach, W.A.

    1988-02-09

    A device is provided for stabilizing a flexible membrane secured within a frame, wherein a plurality of elongated arms are disposed radially from a central hub which penetrates the membrane, said arms imposing alternately against opposite sides of the membrane, thus warping and tensioning the membrane into a condition of improved stability. The membrane may be an opaque or translucent sheet or other material. 10 figs.

  9. Enrichment and characterization of an anammox bacterium from a rotating biological contactor treating ammonium-rich leachate.

    PubMed

    Egli, K; Fanger, U; Alvarez, P J; Siegrist, H; van der Meer, J R; Zehnder, A J

    2001-03-01

    Anaerobic ammonium oxidation with nitrite to N2 (anammox) is a recently discovered microbial reaction with interesting potential for nitrogen removal from wastewater. We enriched an anammox culture from a rotating disk contactor (near Kölliken, Switzerland) that was used to treat ammonium-rich leachate with low organic carbon content. This enrichment led to a relative population size of 88% anammox bacteria. The microorganism carrying out the anammox reaction was identified by analysis of the 16S rDNA sequence and by fluorescence in situ hybridization (FISH) with 16S-rRNA-targeting probes. The percentage sequence identity between the 16S rDNA sequences of the Kölliken anammox organism and the archetype anammox strain Candidatus Brocadia anammoxidans was 90.9%, but between 98.5 and 98.9% with Candidatus Kuenenia stuttgartiensis, an organism identified in biofilms by molecular methods. The Kölliken culture catalyzed the anaerobic oxidation of ammonium with nitrite in a manner seemingly identical to that of Candidatus B. anammoxidans, but exhibited higher tolerance to phosphate (up to 20 mM) and to nitrite (up to 13 mM) and was active at lower cell densities. Anammox activity was observed only between pH 6.5 and 9, with an optimum at pH 8 and a temperature optimum at 37 degrees C. Hydroxylamine and hydrazine, which are intermediates of the anammox reaction of Candidatus B. anammoxidans, were utilized by the Kölliken organisms, and approximately 15% of the nitrite utilized during autotrophic growth was converted to nitrate. Electron microscopy showed a protein-rich region in the center of the cells surrounded by a doughnut-shaped region containing ribosomes and DNA. This doughnut-shape region was observed with FISH as having a higher fluorescence intensity. Similar to Candidatus B. anammoxidans, the Kölliken anammox organism typically formed homogenous clusters containing up to several hundred cells within an extracellular matrix.

  10. The effects of a realistic hollow cathode plasma contactor model on the simulation of bare electrodynamic tether systems

    NASA Astrophysics Data System (ADS)

    Blash, Derek M.

    The region known as Low-Earth Orbit (LEO) has become populated with artificial satellites and space debris since humanities initial venture into the region. This has turned LEO into a hazardous region. Since LEO is very valuable to many different countries, there has been a push to prevent further buildup and talk of even deorbiting spent satellites and debris already in LEO. One of the more attractive concepts available for deorbiting debris and spent satellites is a Bare Electrodynamic Tether (BET). A BET is a propellantless propulsion technique in which two objects are joined together by a thin conducting material. When these tethered objects are placed in LEO, the tether sweeps across the magnetic field lines of the Earth and induces an electromotive force (emf) along the tether. Current from the space plasma is collected on the bare tether under the action of the induced emf, and this current interacts with the Earth's magnetic field to create a drag force that can be used to deorbit spent satellites and space debris. A Plasma Contactor (PC) is used to close the electrical circuit between the BET and the ionospheric plasma. The PC requires a voltage and, depending on the device, a gas flow to emit electrons through a plasma bridge to the ionospheric plasma. The PC also can require a plasma discharge electrode and a heater to condition the PC for operation. These parameters as well as the PC performance are required to build an accurate simulation of a PC and, therefore, a BET deorbiting system. This thesis focuses on the development, validation, and implementation of a simulation tool to model the effects of a realistic hollow cathode PC system model on a BET deorbit system.

  11. Simultaneous Production and Recovery of Fumaric Acid from Immobilized Rhizopus oryzae with a Rotary Biofilm Contactor and an Adsorption Column

    PubMed Central

    Cao, N.; Du, J.; Gong, C. S.; Tsao, G. T.

    1996-01-01

    An integrated system of simultaneous fermentation-adsorption for the production and recovery of fumaric acid from glucose by Rhizopus oryzae was investigated. The system was constructed such that growing Rhizopus mycelia were self-immobilized on the plastic discs of a rotary biofilm contactor during the nitrogen-rich growth phase. During the nongrowth, production phase, the biofilm was alternately exposed to liquid medium and air upon rotation of the discs in the horizontal fermentation vessel. The product of fermentation, fumaric acid, was removed simultaneously and continuously by a coupled adsorption column, thereby moderating inhibition, enhancing the fermentation rate, and sustaining cell viability. Another beneficial effect of the removal of fumaric acid is release of hydroxyl ions from a polyvinyl pyridine adsorbent into the circulating fermentation broth. This moderates the decrease in pH that would otherwise occur. Polyvinyl pyridine and IRA-900 gave the highest loading for this type of fermentation. This fermentation system is capable of producing fumaric acid with an average yield of 85 g/liter from 100 g of glucose per liter within 20 h under repetitive fed-batch cycles. On a weight yield basis, 91% of the theoretical maximum was obtained with a productivity of 4.25 g/liter/h. This is in contrast to stirred-tank fermentation supplemented with calcium carbonate, whose average weight yield was 65% after 72 h with a productivity of 0.9 g/liter/h. The immobilized reactor was operated repetitively for 2 weeks without loss of biological activity. PMID:16535381

  12. Accounting: Accountants Need Verbal Skill Training

    ERIC Educational Resources Information Center

    Whitaker, Bruce L.

    1978-01-01

    Verbal skills training is one aspect of accounting education not usually included in secondary and postsecondary accounting courses. The author discusses the need for verbal competency and methods of incorporating it into accounting courses, particularly a variation of the Keller plan of individualized instruction. (MF)

  13. Reduction of VOC emissions by a membrane-based gas absorption process.

    PubMed

    Li, Rui; Xu, Jun; Wang, Lianjun; Li, Jiansheng; Sun, Xiuyun

    2009-01-01

    A membrane-based gas absorption (MGA) process was evaluated for the removal of volatile organic compounds (VOCs) based on C6H6/N2 mixture. The absorption of C6H6 from a C6H6/N2 mixture was investigated using a hydrophobic polypropylene hollow fiber membrane contactor and the aqueous solution of N-formyl morpholine (NFM) as absorbent. The effects of various factors on the overall mass transfer coefficient was investigated. The experimental results showed that the removal efficiency of C6H6 could reach 99.5% in present studied system. A mathematical model based on resistance-in-series concept was presented to predict the value of overall mass transfer coefficient. The average error between the predicted and experimental values is 7.9%. In addition, conventional packed columns for VOCs removal was also evaluated for comparison.

  14. Dialysis membranes for blood purification.

    PubMed

    Sakai, K

    2000-01-01

    All of the artificial membranes in industrial use, such as a reverse-osmosis membrane, dialysis membrane, ultrafiltration membrane, microfiltration membrane and gas separation membrane, also have therapeutic applications. The most commonly used artificial organ is the artificial kidney, a machine that performs treatment known as hemodialysis. This process cleanses the body of a patient with renal failure by dialysis and filtration, simple physicochemical processes. Hemodialysis membranes are used to remove accumulated uremic toxins, excess ions and water from the patient via the dialysate, and to supply (deficit) insufficient ions from the dialysate. Dialysis membranes used clinically in the treatment of patients with renal failure account for by far the largest volume of membranes used worldwide; more than 70 million square meters are used a year. Almost all dialyzers now in use are of the hollow-fiber type. A hollow-fiber dialyzer contains a bundle of approximately 10000 hollow fibers, each with an inner diameter of about 200 microm when wet. The membrane thickness is about 20-45 microm, and the length is 160-250 mm. The walls of the hollow fibers function as the dialysis membrane. Various materials, including cellulose-based materials and synthetic polymers, are used for dialysis membranes. This paper reviews blood purification, hemodialysis and dialysis membranes.

  15. Impact of PAC Fines in Fouling of Polymeric and Ceramic Low-Pressure Membranes for Drinking Water Treatment

    PubMed Central

    Oligny, Laurent; Bérubé, Pierre R.; Barbeau, Benoit

    2016-01-01

    This study assessed the issue of membrane fouling in a Hybrid Membrane Process (HMP) due to the export of powdered activated carbon (PAC) fines from a pretreatment contactor. Two parallel pilot-scale ceramic and polymeric membranes were studied. Reversible and irreversible foulings were measured following three cleaning procedures: Physical backwashing (BW), chemically enhanced backwashing (CEB) and Clean-in-Place (CIP). The impacts on fouling of membrane type, operation flux increase and the presence/absence of the PAC pretreatment were investigated. Membranes without pretreatment were operated in parallel as a control. In addition, CIP washwaters samples were analyzed to measure organic and inorganic foulants removed from the membranes. It was observed that for the polymeric membranes, fouling generally increased with the presence of the PAC pretreatment because of the export of fines. On the contrary, the ceramic membranes were not significantly impacted by their presence. The analysis of CIP washwaters showed a greater total organic carbon (TOC) content on membranes with a PAC pretreatment while no similar conclusion could be made for inorganic foulants. PMID:27399788

  16. Impact of PAC Fines in Fouling of Polymeric and Ceramic Low-Pressure Membranes for Drinking Water Treatment.

    PubMed

    Oligny, Laurent; Bérubé, Pierre R; Barbeau, Benoit

    2016-07-07

    This study assessed the issue of membrane fouling in a Hybrid Membrane Process (HMP) due to the export of powdered activated carbon (PAC) fines from a pretreatment contactor. Two parallel pilot-scale ceramic and polymeric membranes were studied. Reversible and irreversible foulings were measured following three cleaning procedures: Physical backwashing (BW), chemically enhanced backwashing (CEB) and Clean-in-Place (CIP). The impacts on fouling of membrane type, operation flux increase and the presence/absence of the PAC pretreatment were investigated. Membranes without pretreatment were operated in parallel as a control. In addition, CIP washwaters samples were analyzed to measure organic and inorganic foulants removed from the membranes. It was observed that for the polymeric membranes, fouling generally increased with the presence of the PAC pretreatment because of the export of fines. On the contrary, the ceramic membranes were not significantly impacted by their presence. The analysis of CIP washwaters showed a greater total organic carbon (TOC) content on membranes with a PAC pretreatment while no similar conclusion could be made for inorganic foulants.

  17. The effects of non-solvent on surface morphology and hydrophobicity of dip-coated polypropylene membrane

    NASA Astrophysics Data System (ADS)

    Faiqotul Himma, Nurul; Kusuma Wardani, Anita; Gede Wenten, I.

    2017-05-01

    Polypropylene (PP) has been widely used for fabrication of hydrophobic microporous membrane due to its good thermal and chemical stability. However, the hydrophobicity of PP is inadequate to prevent membrane wetting which hinders its application in long-term operation of membrane contactor and other hydrophobic membrane processes. Endowing the membrane with superhydrophobicity has become an attractive way to improve wetting resistance. In this work, superhydrophobic PP membrane was prepared by coating with roughened polymer film. A simple technique of two-step dip-coating was used for deposition of the non-solvent solution and polymer solution. The effects of five non-solvent types were investigated, including ethanol, isopropyl alcohol (IPA), acetone, methyl ethyl ketone (MEK), and cyclohexanone. All non-solvents increased the surface roughness, leading to an improvement of membrane hydrophobicity. Superhydrophobic PP membranes with high water contact angle (WCA) of 150.4° and 151.3° have been successfully prepared by using IPA and MEK, respectively. Morphology characterization revealed that both modified membranes had more uniform and larger number of smaller aggregates which might minimize surface area in contact with liquid, resulting in increased contact angle. As the coating was conducted separately, the utilization of non-solvent could be more effective.

  18. Characterization of an Autotrophic Nitrogen-Removing Biofilm from a Highly Loaded Lab-Scale Rotating Biological Contactor

    PubMed Central

    Pynaert, Kris; Smets, Barth F.; Wyffels, Stijn; Beheydt, Daan; Siciliano, Steven D.; Verstraete, Willy

    2003-01-01

    In this study, a lab-scale rotating biological contactor (RBC) treating a synthetic NH4+ wastewater devoid of organic carbon and showing high N losses was examined for several important physiological and microbial characteristics. The RBC biofilm removed 89% ± 5% of the influent N at the highest surface load of approximately 8.3 g of N m−2 day−1, with N2 as the main end product. In batch tests, the RBC biomass showed good aerobic and anoxic ammonium oxidation (147.8 ± 7.6 and 76.5 ± 6.4 mg of NH4+-N g of volatile suspended solids [VSS]−1 day−1, respectively) and almost no nitrite oxidation (< 1 mg of N g of VSS−1 day−1). The diversity of aerobic ammonia-oxidizing bacteria (AAOB) and planctomycetes in the biofilm was characterized by cloning and sequencing of PCR-amplified partial 16S rRNA genes. Phylogenetic analysis of the clones revealed that the AAOB community was fairly homogeneous and was dominated by Nitrosomonas-like species. Close relatives of the known anaerobic ammonia-oxidizing bacterium (AnAOB) Kuenenia stuttgartiensis dominated the planctomycete community and were most probably responsible for anoxic ammonium oxidation in the RBC. Use of a less specific planctomycete primer set, not amplifying the AnAOB, showed a high diversity among other planctomycetes, with representatives of all known groups present in the biofilm. The spatial organization of the biofilm was characterized using fluorescence in situ hybridization (FISH) with confocal scanning laser microscopy (CSLM). The latter showed that AAOB occurred side by side with putative AnAOB (cells hybridizing with probe PLA46 and AMX820/KST1275) throughout the biofilm, while other planctomycetes hybridizing with probe PLA886 (not detecting the known AnAOB) were present as very conspicuous spherical structures. This study reveals that long-term operation of a lab-scale RBC on a synthetic NH4+ wastewater devoid of organic carbon yields a stable biofilm in which two bacterial groups, thought

  19. Photocatalytic oxidation of 2,4,6-trichlorophenol in water using a cocurrent downflow contactor reactor (CDCR).

    PubMed

    Ochuma, Idoko J; Fishwick, Robert P; Wood, Joseph; Winterbottom, J Mike

    2007-06-18

    The heterogeneous photocatalytic oxidation of aqueous solutions of 2,4,6-trichlorophenol (2,4,6-TCP) as a model pollutant in industrial wastewater has been carried out in a pilot scale cocurrent downflow contactor reactor (CDCR). The reactions were carried out in the presence of Ultra-Violet radiation, O(2) and TiO(2) photocatalyst (VP Aeroperl P25/20). The TiO(2) was characterized by Dynamic Vapour Sorption (DVS) technique giving specific surface area and surface energy of 46.06 m(2)g(-1) and 80.12 mJ m(-2), respectively. The CDC reactor was fitted with an internally and vertically mounted 1.0 kW or 2.0 kW UV lamp. The reactions were carried out at 50 degrees C and 1 bar, with the reactor being operated in closed loop recycle mode and suspended photocatalyst being re-circulated. The CDC reactor, a device of very high mass transfer efficiency giving unusually large gas hold-up of approximately 50%, was operated with oxygen mass transfer and dissolution in the zone above the UV lamp (high mass transfer zone) and along and around the UV lamp housing (reaction zone). Under optimized reaction conditions, 100% conversion of 2,4,6-TCP was achieved in 180 min using 15 dm(3) solutions with initial concentration of 120 mg dm(-3). A combination of TiO(2) photocatalyst, UV irradiation and oxidant was observed to give the most rapid photodegradation and photomineralization of the 2,4,6-TCP in comparison with irradiation only. Using the 1 kW or 2 kW UV lamps, conversion of 100 mg dm(-3) of 2,4,6-TCP after 30 min was 62.51% and 90.71%, respectively, with initial reaction rates of 1.33 x 10(-5) and 4.22 x 10(-5) mol min(-1), respectively, and rate constants 0.0046 and 0.29 min(-1), respectively.

  20. International Accounting and the Accounting Educator.

    ERIC Educational Resources Information Center

    Laribee, Stephen F.

    The American Assembly of Collegiate Schools of Business (AACSB) has been instrumental in internationalizing the accounting curriculum by means of accreditation requirements and standards. Colleges and universities have met the AACSB requirements either by providing separate international accounting courses or by integrating international topics…

  1. International Accounting and the Accounting Educator.

    ERIC Educational Resources Information Center

    Laribee, Stephen F.

    The American Assembly of Collegiate Schools of Business (AACSB) has been instrumental in internationalizing the accounting curriculum by means of accreditation requirements and standards. Colleges and universities have met the AACSB requirements either by providing separate international accounting courses or by integrating international topics…

  2. How "accountable" are accountable care organizations?

    PubMed

    Addicott, Rachael; Shortell, Stephen M

    2014-01-01

    The establishment of accountable care organizations (ACOs) in the Affordable Care Act (ACA) was intended to support both cost savings and high-quality care. However, a key challenge will be to ensure that governance and accountability mechanisms are sufficient to support those twin ambitions. This exploratory study considers how recently developed ACOs have established governance structures and accountability mechanisms, particularly focusing on attempts at collaborative accountability and shared governance arrangements. Four case studies of ACOs across the United States were undertaken, with data collected throughout 2012. These involved 34 semistructured interviews with ACO administrative and clinical leaders, observation of nine meetings, and a review of documentary materials from each ACO. We identified very few examples of physicians being held to account as a collective and therefore only limited evidence of collaborative accountability impacting on behavior change. However, ACO leaders do have many mechanisms available to stimulate change across physicians. The challenge is to determine governance structure(s) and accountability mechanisms that facilitate the most effective combination of approaches, measures, incentives, and sanctions to achieve the goals of more accountable care. Accountability structures and processes will need to be tailored to local membership composition, historical evolution, and current stage of development. There are also some common lessons to be drawn. Shared goals and incentives should be reflected through performance criteria. It is important to align measures and thresholds across payers to ensure ACOs are not unnecessarily burdened or compromised by reporting on different and potentially disjointed measures. Finally, emphasis needs to be placed on the importance of credible, transparent data. This exploratory study provides early evidence regarding how ACOs are establishing their governance and accountability arrangements and

  3. A Harmonious Accounting Duo?

    ERIC Educational Resources Information Center

    Schapperle, Robert F.; Hardiman, Patrick F.

    1992-01-01

    Accountants have urged "harmonization" of standards between the Governmental Accounting Standards Board and the Financial Accounting Standards Board, recommending similar reporting of like transactions. However, varying display of similar accounting events does not necessarily indicate disharmony. The potential for problems because of…

  4. Custom accounts receivable modeling.

    PubMed

    Veazie, J

    1994-04-01

    In hospital and clinic management, accounts are valued as units and handled equally--a $20 account receives the same minimum number of statements as a $20,000 account. Quite often, the sheer number of accounts a hospital or clinic has to handle forces executives to manage accounts by default and failure--accounts mature on an aging track and, if left unpaid by patients, eventually are sent to collections personnel. Of the bad-debt accounts placed with collections agencies, many are misclassified as charity or hardship cases, while others could be collected by hospital or clinic staff with a limited amount of additional effort.

  5. The Excitable Membrane

    PubMed Central

    Offner, Franklin F.

    1972-01-01

    The model of the excitable membrane assumes common channels for Na+ and K+; the two ion species interact within the pores through their electrostatic forces. The electric field varies across the membrane and with time, as a result of ionic redistribution. Ionic flow is primarily controlled by energy barriers at the two interfaces and by Ca++ adsorption at the external interface. When the membrane is polarized, the high electric field at the external interface acting on the membrane fixed charge keeps the effective channel diameter small, so that only dihydrated ions can cross the interface. The higher energy required to partially dehydrate Na+ accounts for its lower permeability when polarized. Depolarized, the channel entrance can expand, permitting quadrihydrated ions to pass; the large initial Na+ flow is the result of the large concentration ratio across the interface. The effect at the internal interface is symmetric; Na+ crosses with greater difficulty when the membrane is depolarized. Na+ inactivation occurs when the ion distribution within the membrane has assumed its new steady-state value. Calculations based on parameters consistent with physicochemical data agree generally with a wide range of experiments. The model does not obey the two fundamental Hodgkin-Huxley (HH) postulates (independence principle, ion flow proportional to thermodynamic potential). In several instances the model predicts experimental results which are not predicted by the HH equations. ImagesFIGURE 12 PMID:4655662

  6. Safeguards Accountability Network accountability and materials management

    SciTech Connect

    Carnival, G.J.; Meredith, E.M.

    1985-01-01

    The Safeguards Accountability Network (SAN) is an on-line accountability system used by Rocky Flats Plant to provide accountability control of its nuclear material inventory. The system is also used to monitor and evaluate the use of the nuclear material inventory against programmatic objectives for materials management. The SAN system utilizes two Harris 800 Computers as central processing units. Enhancement plans are currently being formulated to provide automated data collection from process operations on the shop floor and from non-destructive analysis safeguards instrumentation. SAN, discussed in this paper, is an excellent system for basic accountability control of nuclear materials inventories and is a quite useful tool in evaluating the efficient use of nuclear materials inventories at Rocky Flats Plant.

  7. Sulfonamide antibiotic removal and nitrogen recovery from synthetic urine by the combination of rotating advanced oxidation contactor and methylene urea synthesis process.

    PubMed

    Fukahori, S; Fujiwara, T; Ito, R; Funamizu, N

    2015-01-01

    The combination of nitrogen recovery and pharmaceutical removal processes for livestock urine treatment were investigated to suppress the discharge of pollutants and recover nitrogen as resources. We combined methylene urea synthesis from urea and adsorption and photocatalytic decomposition of sulfonamide antibiotic using rotating advanced oxidation contactor (RAOC) contained for obtaining both safe fertilizer and reclaimed water. The methylene urea synthesis could recover urea in synthetic urine, however, almost all sulfonamide antibiotic was also incorporated, which is unfavorable from a safety aspect if the methylene urea is to be used as fertilizer. Conversely, RAOC could remove sulfonamide antibiotic without consuming urea. It was also confirmed that the methylene urea could be synthesized from synthetic urine treated by RAOC. Thus, we concluded that RAOC should be inserted prior to the nitrogen recovery process for effective treatment of urine and safe use of methylene urea as fertilizer.

  8. Multicomponent membranes

    DOEpatents

    Kulprathipanja, Santi; Kulkarni, Sudhir S.; Funk, Edward W.

    1988-01-01

    A multicomponent membrane which may be used for separating various components which are present in a fluid feed mixture comprises a mixture of a plasticizer such as a glycol and an organic polymer cast upon a porous organic polymer support. The membrane may be prepared by casting an emulsion or a solution of the plasticizer and polymer on the porous support, evaporating the solvent and recovering the membrane after curing.

  9. Spermatozoa in the sperm-peak-fraction of the boar ejaculate show a lower flow of Ca(2+) under capacitation conditions post-thaw which might account for their higher membrane stability after cryopreservation.

    PubMed

    Hossain, Md Sharoare; Johannisson, Anders; Siqueira, Amanda Pimenta; Wallgren, Margareta; Rodriguez-Martinez, Heriberto

    2011-10-01

    Boar spermatozoa collected in the ejaculate sperm peak-portion (P1, first 10 mL of the sperm-rich fraction, SRF), had shown a higher resilience to freezing and thawing compared to spermatozoa from the rest of the ejaculate (2nd portion of the SRF plus the post-sperm-rich fraction, PSRF), even when using a simplified freezing technique, as long as spermatozoa were incubated in their own seminal plasma (SP). This experiment studied the stability of P1- and SRF-P1 boar spermatozoa frozen in MiniFlatPacks (MFP), post-thaw, using flow cytometry. Since spermatozoa from either portion showed similar cryosurvival and low proportions of unstable membranes (<3%, annexin-V/propidium iodide staining), and only a tendency for SRF-P1 live spermatozoa to depict acrosome exocytosis (FITC-PNA/PI/H33342); they were explored for Ca(2+) contents using a Fluo-4 probe under in vitro capacitating conditions (mBO+ medium), as well they were tested for their ability to sustain a short Ca(2+)-ionophore (A23187) in vitro challenge. The proportions of live spermatozoa depicting high Ca(2+)-levels were initially <2% but increased over incubation time, particularly in SRF-P1(P<0.05), while proportions of live spermatozoa with low Ca(2+)-levels were basically constant over incubation time (~11-14%), for either portion. Incubation in capacitation medium did not modify the proportions of low-Ca(2+) but dramatically increased the proportions of high-Ca(2+) spermatozoa (P<0.001) already after 15 min exposure, highest for SRF-P1 spermatozoa. While the proportion of live spermatozoa with intact acrosome was significantly decreased among SRF-P1 (P<0.001), that of P1-spermatozoa remained unchanged, probably owing to the lowest relative content of cytosolic Ca(2+). The results suggest that spermatozoa in the P1-portion are more resilient to express acrosome exocytosis post-thaw compared to those bathing in the rest of the SRF-fraction when cryopreserved using a simplified technique, in MFPs.

  10. Accountable Care Organizations and Oral Health Accountability.

    PubMed

    Mayberry, Melanie E

    2017-05-01

    Accountable care organizations agree to be accountable for the cost and outcomes of an attributed population. However, in many, no provisions have been made to account for oral health. There are several social, medical, and financial implications for health care provider and payer systems and health care outcomes when oral health is not accounted for in patient management. How can an organization strive to improve population health without including the oral health system? Total systemic health for a population must include oral health. Accountable care organizations are positioned to change the course of oral health in the United States and close the disparities that exist among vulnerable populations, including seniors. Such efforts will reduce health care costs. Opportunities abound to expand points of entry into the health care system via dental or medical care. Closing the great divide between 2 historically isolated professions will position the United States to make gains in true population health. I provide evidence of the need to mandate access to oral health care services for all Americans-specifically adults, because legislation currently exists for pediatric dental coverage.

  11. LMAL Accounting Office 1936

    NASA Technical Reports Server (NTRS)

    1936-01-01

    Accounting Office: The Langley Memorial Aeronautical Laboratory's accounting office, 1936, with photographs of the Wright brothers on the wall. Although the Lab was named after Samuel P. Langley, most of the NACA staff held the Wrights as their heroes.

  12. The Accounting Capstone Problem

    ERIC Educational Resources Information Center

    Elrod, Henry; Norris, J. T.

    2012-01-01

    Capstone courses in accounting programs bring students experiences integrating across the curriculum (University of Washington, 2005) and offer unique (Sanyal, 2003) and transformative experiences (Sill, Harward, & Cooper, 2009). Students take many accounting courses without preparing complete sets of financial statements. Accountants not only…

  13. Intelligent Accountability in Education

    ERIC Educational Resources Information Center

    O'Neill, Onora

    2013-01-01

    Systems of accountability are "second order" ways of using evidence of the standard to which "first order" tasks are carried out for a great variety of purposes. However, more accountability is not always better, and processes of holding to account can impose high costs without securing substantial benefits. At their worst,…

  14. Accounting Education in Crisis

    ERIC Educational Resources Information Center

    Turner, Karen F.; Reed, Ronald O.; Greiman, Janel

    2011-01-01

    Almost on a daily basis new accounting rules and laws are put into use, creating information that must be known and learned by the accounting faculty and then introduced to and understood by the accounting student. Even with the 150 hours of education now required for CPA licensure, it is impossible to teach and learn all there is to learn. Over…

  15. Accounting & Computing Curriculum Guide.

    ERIC Educational Resources Information Center

    Avani, Nathan T.; And Others

    This curriculum guide consists of materials for use in teaching a competency-based accounting and computing course that is designed to prepare students for employability in the following occupational areas: inventory control clerk, invoice clerk, payroll clerk, traffic clerk, general ledger bookkeeper, accounting clerk, account information clerk,…

  16. Managerial Accounting. Study Guide.

    ERIC Educational Resources Information Center

    Plachta, Leonard E.

    This self-instructional study guide is part of the materials for a college-level programmed course in managerial accounting. The study guide is intended for use by students in conjuction with a separate textbook, Horngren's "Accounting for Management Control: An Introduction," and a workbook, Curry's "Student Guide to Accounting for Management…

  17. Automated Accounting. Instructor Guide.

    ERIC Educational Resources Information Center

    Moses, Duane R.

    This curriculum guide was developed to assist business instructors using Dac Easy Accounting College Edition Version 2.0 software in their accounting programs. The module consists of four units containing assignment sheets and job sheets designed to enable students to master competencies identified in the area of automated accounting. The first…

  18. Intelligent Accountability in Education

    ERIC Educational Resources Information Center

    O'Neill, Onora

    2013-01-01

    Systems of accountability are "second order" ways of using evidence of the standard to which "first order" tasks are carried out for a great variety of purposes. However, more accountability is not always better, and processes of holding to account can impose high costs without securing substantial benefits. At their worst,…

  19. Accounting & Computing Curriculum Guide.

    ERIC Educational Resources Information Center

    Avani, Nathan T.; And Others

    This curriculum guide consists of materials for use in teaching a competency-based accounting and computing course that is designed to prepare students for employability in the following occupational areas: inventory control clerk, invoice clerk, payroll clerk, traffic clerk, general ledger bookkeeper, accounting clerk, account information clerk,…

  20. Development of a Supported Emulsion Liquid Membrane System for Propionic Acid Separation in a Microgravity Environment

    NASA Technical Reports Server (NTRS)

    Li, Jin; Hu, Shih-Yao B.; Wiencek, John M.

    2001-01-01

    Perstractive fermentation is a good way to increase the productivity of bioreactors. Using Propionibacteria as the model system, the feasibility of using supported emulsion liquid membrane (SELM) for perstractive fermentation is assessed in this study. Five industrial solvents were considered as the solvent for preparing the SELM. The more polar a solvent is, the higher the partition coefficient. However, toxicity of a solvent also increases with its polarity. CO-1055 (industrial decanol/octanol blend) has the highest partition coefficient toward propionic acid among the solvents that has no molecular toxicity toward Propionibacteria. A preliminary extraction study was conducted using tetradecane as solvent in a hydrophobic hollow fiber contactor. The result confirmed that SELM eliminates the equilibrium limitation of conventional liquid-liquid extraction, and allows the use of a non-toxic solvent with low partition coefficient.

  1. Development of a Supported Emulsion Liquid Membrane System for Propionic Acid Separation in a Microgravity Environment

    NASA Technical Reports Server (NTRS)

    Li, Jin; Hu, Shih-Yao B.; Wiencek, John M.

    2001-01-01

    Perstractive fermentation is a good way to increase the productivity of bioreactors. Using Propionibacteria as the model system, the feasibility of using supported emulsion liquid membrane (SELM) for perstractive fermentation is assessed in this study. Five industrial solvents were considered as the solvent for preparing the SELM. The more polar a solvent is, the higher the partition coefficient. However, toxicity of a solvent also increases with its polarity. CO-1055 (industrial decanol/octanol blend) has the highest partition coefficient toward propionic acid among the solvents that has no molecular toxicity toward Propionibacteria. A preliminary extraction study was conducted using tetradecane as solvent in a hydrophobic hollow fiber contactor. The result confirmed that SELM eliminates the equilibrium limitation of conventional liquid-liquid extraction, and allows the use of a non-toxic solvent with low partition coefficient.

  2. [Epiretinal membranes].

    PubMed

    Dupas, B; Tadayoni, R; Gaudric, A

    2015-11-01

    Idiopathic epiretinal membranes represent a common condition, and are present in approximately 10% of people over the age of 70 years. They are idiopathic in 80% of cases, or may be secondary to various conditions such as a prior retinal detachment, or vascular or inflammatory retinal diseases. The main symptoms are visual loss and metamorphopsia. The diagnosis of epiretinal membrane is currently facilitated by OCT, which provides prognostic and therapeutic decision-making assistance. Surgery for epiretinal membranes is currently well codified through sutureless vitrectomy and dyes. Dissection of the membrane (with or without associated peeling of the internal limiting membrane) ensures good anatomical and functional results, while being relatively minimally invasive. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. Effect of oscillatory flow on the performance of a novel cross-flow affinity membrane device

    SciTech Connect

    Najarian, S.; Bellhouse, B.J.

    1997-01-01

    This paper presents the results of an investigation into the effect of oscillatory flow in a membrane-based affinity contactor. This device was designed to accommodate a tubular affinity membrane, and the flow direction of working fluid was tangential to the surface of the membrane. Cibacron Blue F3G-A was utilized as the capturing ligand and bovine serum albumin as the target molecule. The dye molecules were immobilized covalently via spaced molecules (polyethylenimine) onto the pores of a microfiltration membrane with a pore size rating of 0.45{mu}m. Bovine serum albumin was pumped through the annular space between the concentric screw-threaded insert and the tubular membrane in oscillatory flow with a mean flow component. The effects of pulsation frequency and stroke length were investigated. It was found that, as a result of the pulsatile flow, the protein recovery was increased by a factor of 2. To make the interpretation of the results easier, various dimensionless groups were defined specifically for this system and the experimental data were reported in terms of these groups. 25 refs., 5 figs.

  4. Production of surfactin and fengycin by Bacillus subtilis in a bubbleless membrane bioreactor.

    PubMed

    Coutte, François; Lecouturier, Didier; Yahia, Saliha Ait; Leclère, Valérie; Béchet, Max; Jacques, Philippe; Dhulster, Pascal

    2010-06-01

    Surfactin and fengycin are lipopeptide biosurfactants produced by Bacillus subtilis. This work describes for the first time the use of bubbleless bioreactors for the production of these lipopeptides by B. subtilis ATCC 21332 with aeration by a hollow fiber membrane air-liquid contactor to prevent foam formation. Three different configurations were tested: external aeration module made from either polyethersulfone (reactor BB1) or polypropylene (reactor BB2) and a submerged module in polypropylene (reactor BB3). Bacterial growth, glucose consumption, lipopeptide production, and oxygen uptake rate were monitored during the culture in the bioreactors. For all the tested membranes, the bioreactors were of satisfactory bacterial growth and lipopeptide production. In the three configurations, surfactin production related to the culture volume was in the same range: 242, 230, and 188 mg l(-1) for BB1, BB2, and BB3, respectively. Interestingly, high differences were observed for fengycin production: 47 mg l(-1) for BB1, 207 mg l(-1) for BB2, and 393 mg l(-1) for BB3. A significant proportion of surfactin was adsorbed on the membranes and reduced the volumetric oxygen mass transfer coefficient. The degree of adsorption depended on both the material and the structure of the membrane and was higher with the submerged polypropylene membrane.

  5. Accounting: "Balancing Out" the Accounting Program.

    ERIC Educational Resources Information Center

    Babcock, Coleen

    1979-01-01

    The vocational accounting laboratory is a viable, meaningful educational experience for high school seniors, due to the uniqueness of its educational approach and the direct involvement of the professional and business community. A balance of experiences is provided to match individual needs and goals of students. (CT)

  6. LIQUID CYCLONE CONTACTOR

    DOEpatents

    Whatley, M.E.; Woods, W.M.

    1962-09-01

    This invention relates to liquid-liquid extraction systems. The invention, an improved hydroclone system, comprises a series of serially connected, axially aligned hydroclones, each of which is provided with an axially aligned overflow chamber. The chambers are so arranged that rotational motion of a fluid being passed through the system is not lost in passing from chamber to chamber; consequently, this system is highly efficient in contacting and separating two immiscible liquids. (AEC)

  7. Protein-Induced Membrane Curvature Alters Local Membrane Tension

    PubMed Central

    Rangamani, Padmini; Mandadap, Kranthi K.; Oster, George

    2014-01-01

    Adsorption of proteins onto membranes can alter the local membrane curvature. This phenomenon has been observed in biological processes such as endocytosis, tubulation, and vesiculation. However, it is not clear how the local surface properties of the membrane, such as membrane tension, change in response to protein adsorption. In this article, we show that the partial differential equations arising from classical elastic model of lipid membranes, which account for simultaneous changes in shape and membrane tension due to protein adsorption in a local region, cannot be solved for nonaxisymmetric geometries using straightforward numerical techniques; instead, a viscous-elastic formulation is necessary to fully describe the system. Therefore, we develop a viscous-elastic model for inhomogeneous membranes of the Helfrich type. Using the newly available viscous-elastic model, we find that the lipids flow to accommodate changes in membrane curvature during protein adsorption. We show that, at the end of protein adsorption process, the system sustains a residual local tension to balance the difference between the actual mean curvature and the imposed spontaneous curvature. We also show that this change in membrane tension can have a functional impact such as altered response to pulling forces in the presence of proteins. PMID:25099814

  8. Crystalline Membranes

    NASA Technical Reports Server (NTRS)

    Tsapatsis, Michael (Inventor); Lai, Zhiping (Inventor)

    2008-01-01

    In certain aspects, the invention features methods for forming crystalline membranes (e.g., a membrane of a framework material, such as a zeolite) by inducing secondary growth in a layer of oriented seed crystals. The rate of growth of the seed crystals in the plane of the substrate is controlled to be comparable to the rate of growth out of the plane. As a result, a crystalline membrane can form a substantially continuous layer including grains of uniform crystallographic orientation that extend through the depth of the layer.

  9. Emerging accounting trends accounting for leases.

    PubMed

    Valletta, Robert; Huggins, Brian

    2010-12-01

    A new model for lease accounting can have a significant impact on hospitals and healthcare organizations. The new approach proposes a "right-of-use" model that involves complex estimates and significant administrative burden. Hospitals and health systems that draw heavily on lease arrangements should start preparing for the new approach now even though guidance and a final rule are not expected until mid-2011. This article highlights a number of considerations from the lessee point of view.

  10. Biological membranes

    PubMed Central

    Watson, Helen

    2015-01-01

    Biological membranes allow life as we know it to exist. They form cells and enable separation between the inside and outside of an organism, controlling by means of their selective permeability which substances enter and leave. By allowing gradients of ions to be created across them, membranes also enable living organisms to generate energy. In addition, they control the flow of messages between cells by sending, receiving and processing information in the form of chemical and electrical signals. This essay summarizes the structure and function of membranes and the proteins within them, and describes their role in trafficking and transport, and their involvement in health and disease. Techniques for studying membranes are also discussed. PMID:26504250

  11. Strategies for the purification of membrane proteins.

    PubMed

    Smith, Sinead Marian

    2011-01-01

    Although membrane proteins account for 20-30% of the coding regions of all sequenced genomes and play crucial roles in many fundamental cell processes, there are relatively few membranes proteins with known 3D structure. This is likely due to technical challenges associated with membrane protein extraction, solubilisation, and purification. Membrane proteins are classified based on the level of interaction with membrane lipid bilayers, with peripheral membrane proteins associating non-covalently with the membrane, and integral membrane proteins associating more strongly by means of hydrophobic interactions. Generally speaking, peripheral membrane proteins can be purified by milder techniques than integral membrane proteins, whose extraction requires phospholipid bilayer disruption by detergents. Here, important criteria for strategies of membrane protein purification are addressed, with a focus on the initial stages of membrane protein solublilisation, where problems are most frequently encountered. Protocols are outlined for the successful extraction of peripheral membrane proteins, solubilisation of integral membrane proteins, and detergent removal which is important not only for retaining native protein stability and biological functions, but also for the efficiency of later purification techniques.

  12. The Accountability Illusion: Massachusetts

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  13. The Coming Accounting Crisis

    ERIC Educational Resources Information Center

    Eaton, Tim V.

    2007-01-01

    The accounting profession is facing a potential crisis not only from the overall shortage of accounting faculty driven by smaller numbers of new faculty entering the profession as many existing faculty retire but also from changes that have been less well documented. This includes: (1) changes in attitude towards the roles of teaching, service and…

  14. The Evolution of Accountability

    ERIC Educational Resources Information Center

    Webb, P. Taylor

    2011-01-01

    Campus 2020: Thinking ahead is a policy in British Columbia (BC), Canada, that attempted to hold universities accountable to performance. Within, I demonstrate how this Canadian articulation of educational accountability intended to develop "governmentality constellations" to control the university and regulate its knowledge output. This…

  15. The Accountability Illusion: Florida

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  16. Computerizing the Accounting Curriculum.

    ERIC Educational Resources Information Center

    Nash, John F.; England, Thomas G.

    1986-01-01

    Discusses the use of computers in college accounting courses. Argues that the success of new efforts in using computers in teaching accounting is dependent upon increasing instructors' computer skills, and choosing appropriate hardware and software, including commercially available business software packages. (TW)

  17. Cluster Guide. Accounting Occupations.

    ERIC Educational Resources Information Center

    Beaverton School District 48, OR.

    Based on a recent task inventory of key occupations in the accounting cluster taken in the Portland, Oregon, area, this curriculum guide is intended to assist administrators and teachers in the design and implementation of high school accounting cluster programs. The guide is divided into four major sections: program organization and…

  18. PLATO IV Accountancy Index.

    ERIC Educational Resources Information Center

    Pondy, Dorothy, Comp.

    The catalog was compiled to assist instructors in planning community college and university curricula using the 48 computer-assisted accountancy lessons available on PLATO IV (Programmed Logic for Automatic Teaching Operation) for first semester accounting courses. It contains information on lesson access, lists of acceptable abbreviations for…

  19. Teaching Accounting with Computers.

    ERIC Educational Resources Information Center

    Shaoul, Jean

    This paper addresses the numerous ways that computers may be used to enhance the teaching of accounting and business topics. It focuses on the pedagogical use of spreadsheet software to improve the conceptual coverage of accounting principles and practice, increase student understanding by involvement in the solution process, and reduce the amount…

  20. The Accountability Illusion: Illinois

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  1. Accountability in Education.

    ERIC Educational Resources Information Center

    Chippendale, P. R., Ed.; Wilkes, Paula V., Ed.

    This collection of papers delivered at a conference on accountability held at Darling Downs Institute of Advanced Education in Australia examines the meaning of accountability in education for teachers, lecturers, government, parents, administrators, education authorities, and the society at large. In Part 1, W. G. Walker attempts to answer the…

  2. The Accountability Illusion: Colorado

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  3. The Accountability Illusion: Montana

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  4. The Accountability Illusion: Arizona

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  5. The Accountability Illusion: Wyoming

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  6. The Accountability Illusion: Maine

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  7. The Accountability Illusion: Delaware

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  8. The Choreography of Accountability

    ERIC Educational Resources Information Center

    Webb, P. Taylor

    2006-01-01

    The prevailing performance discourse in education claims school improvements can be achieved through transparent accountability procedures. The article identifies how teachers generate performances of their work in order to satisfy accountability demands. By identifying sources of teachers' knowledge that produce choreographed performances, I…

  9. The Accountability Illusion: Minnesota

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  10. The Accountability Illusion: Wisconsin

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  11. The Accountability Illusion: Vermont

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  12. The Accountability Illusion: Idaho

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  13. Public Accountancy Handbook.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Office of the Professions.

    The laws, rules and regulations of the State Education Department governing public accountancy practice in New York State are provided in this handbook. Licensure requirements are also described, and the forms for obtaining a license and first registration as a certified public accountant are provided. The booklet is divided into the following…

  14. Public Accountancy Handbook.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Office of the Professions.

    A reference guide to laws, rules, and regulations that govern public accountancy practice in New York State is presented. In addition to identifying licensing requirements/procedures for certified public accountants, general provisions of Title VIII of the Education Law are covered, along with state management, professional misconduct, and…

  15. Deterrents to Accountability.

    ERIC Educational Resources Information Center

    Hencley, Stephen P.

    This speech assesses potential deterrents to the implementation of accountability in education. The author divides these deterrents into (1) philosophical-ideological; humanist-behaviorist conflicts, individuality versus "techno-urban fascism," and accountability systems tied to the achievement of cognitive objectives at the lower end of Bloom's…

  16. Leadership for Accountability.

    ERIC Educational Resources Information Center

    Lashway, Larry

    2001-01-01

    This document explores issues of leadership for accountability and reviews five resources on the subject. These include: (1) "Accountability by Carrots and Sticks: Will Incentives and Sanctions Motivate Students, Teachers, and Administrators for Peak Performance?" (Larry Lashway); (2) "Organizing Schools for Teacher Learning"…

  17. The Accountability Illusion: Kansas

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  18. The Accountability Illusion: Washington

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  19. The Choreography of Accountability

    ERIC Educational Resources Information Center

    Webb, P. Taylor

    2006-01-01

    The prevailing performance discourse in education claims school improvements can be achieved through transparent accountability procedures. The article identifies how teachers generate performances of their work in order to satisfy accountability demands. By identifying sources of teachers' knowledge that produce choreographed performances, I…

  20. Accountability in Education.

    ERIC Educational Resources Information Center

    Chippendale, P. R., Ed.; Wilkes, Paula V., Ed.

    This collection of papers delivered at a conference on accountability held at Darling Downs Institute of Advanced Education in Australia examines the meaning of accountability in education for teachers, lecturers, government, parents, administrators, education authorities, and the society at large. In Part 1, W. G. Walker attempts to answer the…

  1. The Evolution of Accountability

    ERIC Educational Resources Information Center

    Webb, P. Taylor

    2011-01-01

    Campus 2020: Thinking ahead is a policy in British Columbia (BC), Canada, that attempted to hold universities accountable to performance. Within, I demonstrate how this Canadian articulation of educational accountability intended to develop "governmentality constellations" to control the university and regulate its knowledge output. This…

  2. The Accountability Illusion: Ohio

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  3. The Accountability Illusion: Nevada

    ERIC Educational Resources Information Center

    Thomas B. Fordham Institute, 2009

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states submit accountability plans to the U.S. Department of Education detailing the rules and…

  4. Evaluation method of membrane performance in membrane distillation process for seawater desalination.

    PubMed

    Chung, Seungjoon; Seo, Chang Duck; Choi, Jae-Hoon; Chung, Jinwook

    2014-01-01

    Membrane distillation (MD) is an emerging desalination technology as an energy-saving alternative to conventional distillation and reverse osmosis method. The selection of appropriate membrane is a prerequisite for the design of an optimized MD process. We proposed a simple approximation method to evaluate the performance of membranes for MD process. Three hollow fibre-type commercial membranes with different thicknesses and pore sizes were tested. Experimental results showed that one membrane was advantageous due to the highest flux, whereas another membrane was due to the lowest feed temperature drop. Regression analyses and multi-stage calculations were used to account for the trade-offeffects of flux and feed temperature drop. The most desirable membrane was selected from tested membranes in terms of the mean flux in a multi-stage process. This method would be useful for the selection of the membranes without complicated simulation techniques.

  5. Treatment of phenol in synthetic saline wastewater by solvent extraction and two-phase membrane biodegradation.

    PubMed

    Juang, Ruey-Shin; Huang, Wen-Ching; Hsu, Ya-Han

    2009-05-15

    Phenol in synthetic saline (100gL(-1) NaCl) and acidic (pH 3) wastewater was treated by a hybrid solvent extraction and two-phase membrane biodegradation process at 30 degrees C. Kerosene was adopted to be the organic solvent because it was biocompatible and had a suitable partition coefficient for phenol. Phenol in water was first extracted by kerosene in a batch stirred vessel and the loaded solvent was passed through the lumen of a polyvinylidene fluoride (PVDF) hollow-fiber membrane contactor; in the meantime, Pseudomonas putida BCRC 14365 in mineral salt medium was flowed across the shell, to which tetrasodium phyophosphate (1gL(-1)) was added as a dispersing agent. The effect of the initial phenol level in wastewater (110-2400mgL(-1)) on phenol removal and cell growth was experimentally studied. At a cell concentration of 0.023gL(-1), it was shown that the removal of phenol from saline wastewater was more efficient at a level of 2000mgL(-1) when 0.02-m(2) membrane module was used. The effects of bigger membrane module size (0.19m(2) area) and higher initial cell concentration (0.092-0.23gL(-1)) on the performance of such a hybrid process for the treatment of higher-level phenol in saline wastewater was also evaluated and discussed.

  6. Reactor performance in terms of COD and nitrogen removal and bacterial community structure of a three-stage rotating bioelectrochemical contactor.

    PubMed

    Sayess, Rassil R; Saikaly, Pascal E; El-Fadel, Mutasem; Li, Dong; Semerjian, Lucy

    2013-02-01

    Integrating microbial fuel cell (MFC) into rotating biological contactor (RBC) creates an opportunity for enhanced removal of COD and nitrogen coupled with energy generation from wastewater. In this study, a three-stage rotating bioelectrochemical contactor (referred to as RBC-MFC unit) integrating MFC with RBC technology was constructed for simultaneous removal of carbonaceous and nitrogenous compounds and electricity generation from a synthetic medium containing acetate and ammonium. The performance of the RBC-MFC unit was compared to a control reactor (referred to as RBC unit) that was operated under the same conditions but without current generation (i.e. open-circuit mode). The effect of hydraulic loading rate (HLR) and COD/N ratio on the performance of the two units was investigated. At low (3.05 gCOD g⁻¹N) and high COD/N ratio (6.64 gCOD g⁻¹N), both units achieved almost similar COD and ammonia-nitrogen removal. However, the RBC-MFC unit achieved significantly higher denitrification and nitrogen removal compared to the RBC unit indicating improved denitrification at the cathode due to current flow. The average voltage under 1000 Ω external resistance ranged between 0.03 and 0.30 V and between 0.02 and 0.21 V for stages 1 and 2 of the RBC-MFC unit. Pyrosequencing analysis of bacterial 16S rRNA gene revealed high bacterial diversity at the anode and cathode of both units. Genera that play a role in nitrification (Nitrospira; Nitrosomonas), denitrification (Comamonas; Thauera) and electricity generation (Geobacter) were identified at the electrodes. Geobacter was only detected on the anode of the RBC-MFC unit. Nitrifiers and denitrifiers were more abundant in the RBC-MFC unit compared to the RBC unit and were largely present on the cathode of both units suggesting that most of the nitrogen removal occurred at the cathode. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Human Resource Accounting.

    DTIC Science & Technology

    1984-12-01

    I AD-RI54 787 HUMAN RESOURCE ACCOUNTING (U) NAVAL POSTGRADUATE SCHOOL 1/2 F MONTEREY CR J C MARTINS DEC 84 1UNCLASSIFIED /G 5/9 NL -~~ .. 2. . L...Monterey, California JUN1im THESISG HUMAN RESOURCE ACCOUNTING by Joaquim C. Martins LLJ.. December 1984 Thesis Advisor: R.A. McGonigal Approved for...REPORT & PECRI00 COVERED Master’s Thesis; Human Resource Accounting Dcme 94- ’ 6. PERFORMING ORG. REPORT NUMBER 7. AUTOR(*) . CONTRACT OR GRANT NUMBER

  8. Metamaterial membranes

    NASA Astrophysics Data System (ADS)

    Restrepo-Flórez, Juan Manuel; Maldovan, Martin

    2017-01-01

    We introduce a new class of metamaterial device to achieve separation of compounds by using coordinate transformations and metamaterial theory. By rationally designing the spatial anisotropy for mass diffusion, we simultaneously concentrate different compounds in different spatial locations, leading to separation of mixtures across a metamaterial membrane. The separation of mixtures into their constituent compounds is critically important in biophysics, biomedical, and chemical applications. We present a practical case where a mixture of oxygen and nitrogen diffusing through a polymeric planar matrix is separated. This work opens doors to new paradigms in membrane separations via coordinate transformations and metamaterials by introducing novel properties and unconventional mass diffusion phenomena.

  9. Readability of Accounting Books.

    ERIC Educational Resources Information Center

    Razek, Joseph R.; And Others

    1982-01-01

    This article describes the results of a survey of the readability of most of the intermediate and advanced accounting textbooks currently in use at colleges and universities throughout the United States. (CT)

  10. Accounting Equals Applied Algebra.

    ERIC Educational Resources Information Center

    Roberts, Sondra

    1997-01-01

    Argues that students should be given mathematics credits for completing accounting classes. Demonstrates that, although the terminology is different, the mathematical concepts are the same as those used in an introductory algebra class. (JOW)

  11. Species accounts. Chapter 4

    Treesearch

    Margaret K. Trani; W. Mark Ford; Brian R., eds. Chapman

    2007-01-01

    Narrative accounts for each species are presented by several authors in a consistent format to convey specific information relative to that mammal. The orders are arranged phylogenetically; families and species are arranged alphabetically to facilitate finding a particular species.

  12. Ideas for the Accounting Classroom.

    ERIC Educational Resources Information Center

    Kerby, Debra; Romine, Jeff

    2003-01-01

    Innovative ideas for accounting education include having students study accounting across historical periods, using businesses for student research, exploring nontraditional accounting careers, and collaborating with professional associations. (SK)

  13. Ideas for the Accounting Classroom.

    ERIC Educational Resources Information Center

    Kerby, Debra; Romine, Jeff

    2003-01-01

    Innovative ideas for accounting education include having students study accounting across historical periods, using businesses for student research, exploring nontraditional accounting careers, and collaborating with professional associations. (SK)

  14. Zeolite membranes: microstructure characterization and permeation mechanisms.

    PubMed

    Yu, Miao; Noble, Richard D; Falconer, John L

    2011-11-15

    Since their first synthesis in the 1940s, zeolites have found wide applications in catalysis, ion-exchange, and adsorption. Although the uniform, molecular-size pores of zeolites and their excellent thermal and chemical stability suggest that zeolites could be an ideal membrane material, continuous polycrystalline zeolite layers for separations were first prepared in the 1990s. Initial attempts to grow continuous zeolite layers on porous supports by in situ hydrothermal synthesis have resulted in membranes with the potential to separate molecules based on differences in molecular size and adsorption strength. Since then, further synthesis efforts have led to the preparation of many types of zeolite membranes and better quality membranes. However, the microstructure features of these membranes, such as defect size, number, and distribution as well as structure flexibility were poorly understood, and the fundamental mechanisms of permeation (adsorption and diffusion), especially for mixtures, were not clear. These gaps in understanding have hindered the design and control of separation processes using zeolite membranes. In this Account, we describe our efforts to characterize microstructures of zeolite membranes and to understand the fundamental adsorption and diffusion behavior of permeating solutes. This Account will focus on the MFI membranes which have been the most widely used but will also present results on other types of zeolite membranes. Using permeation, x-ray diffraction, and optical measurements, we found that the zeolite membrane structures are flexible. The size of defects changed due to adsorption and with variations in temperature. These changes in defect sizes can significantly affect the permeation properties of the membranes. We designed methods to measure mixture adsorption in zeolite crystals from the liquid phase, pure component adsorption in zeolite membranes, and diffusion through zeolite membranes. We hope that better understanding can lead

  15. 76 FR 81295 - Cost Accounting Standards: Cost Accounting Standards 412 and 413-Cost Accounting Standards...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... 9904 Cost Accounting Standards: Cost Accounting Standards 412 and 413--Cost Accounting Standards... Policy 48 CFR Part 9904 Cost Accounting Standards: Cost Accounting Standards 412 and 413--Cost Accounting Standards Pension Harmonization Rule AGENCY: Cost Accounting Standards Board, Office of Federal Procurement...

  16. Collaborative flowsheet development studies using cobalt dicarbollide and phosphine oxide for the partitioning of radionuclides from Idaho Chemical Processing Plant high-activity liquid waste with centrifugal contactors

    SciTech Connect

    Law, J.D.; Herbst, R.S.; Todd, T.A.

    1996-12-31

    Two solvent extraction technologies under development in Russia for the partitioning of radionuclides from radioactive wastes were tested at the Idaho Chemical Processing Plant (ICPP) with simulated high-activity liquid waste (HAW) on a continuous basis using 24 stages of 2-cm diameter centrifugal contactors. Two flowsheet tests were conducted with chlorinated cobalt dicarbollide (ChCoDiC) to evaluate the separation of cesium and strontium from ICPP HAW. Also, a flowsheet test was performed with a derivative of phosphine oxide (POR) to evaluate the separation of actinides, rare earths, and technetium from ICPP HAW. All experiments utilized a non-radioactive HAW simulant prepared to emulate the macro (or matrix) constituents of actual ICPP HAW at their average tank composition. The behavior of the species of interest was monitored using the stable forms of Sr and Cs, europium as a surrogate for americium, and rhenium as a surrogate for technetium. Removal efficiencies and distribution coefficients were determined for each flowsheet at steady-state conditions. Results of this testing indicate the POR and ChCoDiC processes can be used to effectively treat ICPP HAW. This series of tests is a continuation of ongoing efforts to evaluate the applicability of these Russian developed technologies to U.S. nuclear wastes under the auspices of a joint program between the U.S. Department of Energy and the Russian Ministry of Atomic Energy.

  17. Experimental and Model Studies on Continuous Separation of 2-Phenylpropionic Acid Enantiomers by Enantioselective Liquid-Liquid Extraction in Centrifugal Contactor Separators.

    PubMed

    Feng, Xiaofeng; Tang, Kewen; Zhang, Pangliang; Yin, Shuangfeng

    2016-03-01

    Multistage enantioselective liquid-liquid extraction (ELLE) of 2-phenylpropionic acid (2-PPA) enantiomers using hydroxypropyl-β-cyclodextrin (HP-β-CD) as extractant was studied experimentally in a counter-current cascade of centrifugal contactor separators (CCSs). Performance of the process was evaluated by purity (enantiomeric excess, ee) and yield (Y). A multistage equilibrium model was established on the basis of single-stage model for chiral extraction of 2-PPA enantiomers and the law of mass conservation. A series of experiments on the extract phase/washing phase ratio (W/O ratio), extractant concentration, the pH value of aqueous phase, and the number of stages was conducted to verify the multistage equilibrium model. It was found that model predictions were in good agreement with the experimental results. The model was applied to predict and optimize the symmetrical separation of 2-PPA enantiomers. The optimal conditions for symmetric separation involves a W/O ratio of 0.6, pH of 2.5, and HP-β-CD concentration of 0.1 mol L(-1) at a temperature of 278 K, where eeeq (equal enantiomeric excess) can reach up to 37% and Yeq (equal yield) to 69%. By simulation and optimization, the minimum number of stages was evaluated at 98 and 106 for eeeq > 95% and eeeq > 97%.

  18. Biofilm establishment and heavy metal removal capacity of an indigenous mining algal-microbial consortium in a photo-rotating biological contactor.

    PubMed

    Orandi, S; Lewis, D M; Moheimani, N R

    2012-09-01

    An indigenous mining algal-microbial consortium was immobilised within a laboratory-scale photo-rotating biological contactor (PRBC) that was used to investigate the potential for heavy metal removal from acid mine drainage (AMD). The microbial consortium, dominated by Ulothrix sp., was collected from the AMD at the Sar Cheshmeh copper mine in Iran. This paper discusses the parameters required to establish an algal-microbial biofilm used for heavy metal removal, including nutrient requirements and rotational speed. The PRBC was tested using synthesised AMD with the multi-ion and acidic composition of wastewater (containing 18 elements, and with a pH of 3.5 ± 0.5), from which the microbial consortium was collected. The biofilm was successfully developed on the PRBC's disc consortium over 60 days of batch-mode operation. The PRBC was then run continuously with a 24 h hydraulic residence time (HRT) over a ten-week period. Water analysis, performed on a weekly basis, demonstrated the ability of the algal-microbial biofilm to remove 20-50 % of the various metals in the order Cu > Ni > Mn > Zn > Sb > Se > Co > Al. These results clearly indicate the significant potential for indigenous AMD microorganisms to be exploited within a PRBC for AMD treatment.

  19. Membrane magic

    SciTech Connect

    Buecker, B.

    2005-09-01

    The Kansas Power and Light Co.'s La Cyne generating station has found success with membrane filtration water pretreatment technology. The article recounts the process followed in late 2004 to install a Pall Aria 4 microfilter in Unit 1 makeup water system at the plant to produce cleaner water for reverse osmosis feed. 2 figs., 2 photos.

  20. Accounting for the environment.

    PubMed

    Lutz, E; Munasinghe, M

    1991-03-01

    Environmental awareness in the 1980s has led to efforts to improve the current UN System of National Accounts (SNA) for better measurement of the value of environmental resources when estimating income. National governments, the UN, the International Monetary Fund, and the World Bank are interested in solving this issue. The World Bank relies heavily on national aggregates in income accounts compiled by means of the SNA that was published in 1968 and stressed gross domestic product (GDP). GDP measures mainly market activity, but it takes does not consider the consumption of natural capital, and indirectly inhibits sustained development. The deficiencies of the current method of accounting are inconsistent treatment of manmade and natural capital, the omission of natural resources and their depletion from balance sheets, and pollution cleanup costs from national income. In the calculation of GDP pollution is overlooked, and beneficial environmental inputs are valued at zero. The calculation of environmentally adjusted net domestic product (EDP) and environmentally adjusted net income (ENI) would lower income and growth rate, as the World Resources Institute found with respect to Indonesia for 1971-84. When depreciation for oil, timber, and top soil was included the net domestic product (NDP) was only 4% compared with a 7.1% GDP. The World Bank has advocated environmental accounting since 1983 in SNA revisions. The 1989 revised Blue Book of the SNA takes environment concerns into account. Relevant research is under way in Mexico and Papua New Guinea using the UN Statistical Office framework as a system for environmentally adjusted economic accounts that computes EDP and ENI and integrates environmental data with national accounts while preserving SNA concepts.

  1. Thinking about Accountability

    PubMed Central

    Deber, Raisa B.

    2014-01-01

    Accountability is a key component of healthcare reforms, in Canada and internationally, but there is increasing recognition that one size does not fit all. A more nuanced understanding begins with clarifying what is meant by accountability, including specifying for what, by whom, to whom and how. These papers arise from a Partnership for Health System Improvement (PHSI), funded by the Canadian Institutes of Health Research (CIHR), on approaches to accountability that examined accountability across multiple healthcare subsectors in Ontario. The partnership features collaboration among an interdisciplinary team, working with senior policy makers, to clarify what is known about best practices to achieve accountability under various circumstances. This paper presents our conceptual framework. It examines potential approaches (policy instruments) and postulates that their outcomes may vary by subsector depending upon (a) the policy goals being pursued, (b) governance/ownership structures and relationships and (c) the types of goods and services being delivered, and their production characteristics (e.g., contestability, measurability and complexity). PMID:25305385

  2. Suppressing membrane height fluctuations leads to a membrane-mediated interaction among proteins.

    PubMed

    Sapp, Kayla; Maibaum, Lutz

    2016-11-01

    Membrane-induced interactions can play a significant role in the spatial distribution of membrane-bound proteins. We develop a model that combines a continuum description of lipid bilayers with a discrete particle model of proteins to probe the emerging structure of the combined membrane-protein system. Our model takes into account the membrane's elastic behavior, the steric repulsion between proteins, and the quenching of membrane shape fluctuations due to the presence of the proteins. We employ coupled Langevin equations to describe the dynamics of the system. We show that coupling to the membrane induces an attractive interaction among proteins, which may contribute to the clustering of proteins in biological membranes. We investigate the lateral protein diffusion and find that it is reduced due to transient fluctuations in membrane shape.

  3. Accountability for Productivity

    ERIC Educational Resources Information Center

    Wellman, Jane

    2010-01-01

    Productivity gains in higher education won't be made just by improving cost effectiveness or even performance. They need to be documented, communicated, and integrated into a strategic agenda to increase attainment. This requires special attention to "accountability" for productivity, meaning public presentation and communication of evidence about…

  4. Accountability Update, March 2000.

    ERIC Educational Resources Information Center

    Washington State Higher Education Coordinating Board, Olympia.

    This report provides the Washington State legislature, the Governor, and other interested parties with an update on the accountability performance of each of the state's public baccalaureate institutions (Central Washington University, Eastern Washington University, Evergreen State College, Washington State University, Western Washington…

  5. The Accountability Illusion

    ERIC Educational Resources Information Center

    Cronin, John; Dahlin, Michael; Xiang, Yun; McCahon, Donna

    2009-01-01

    The intent of the No Child Left Behind (NCLB) Act of 2001 is to hold schools accountable for ensuring that all their students achieve mastery in reading and math, with a particular focus on groups that have traditionally been left behind. Under NCLB, states have leeway to: (1) Craft their own academic standards, select their own tests, and define…

  6. Full Accounting for Curriculum.

    ERIC Educational Resources Information Center

    Paddock, Marie-Louise

    1988-01-01

    Given the curriculum's importance in the educational process, curriculum evaluation should be considered as essential as a district financial audit. When Fenwick English conducted a 1979 curriculum audit of Columbus, Ohio, schools, the accounting firm encountered numerous problems concerning development, review, and management practices. Planning…

  7. Accountability: A Rationale.

    ERIC Educational Resources Information Center

    Brademas, John

    1974-01-01

    The idea of accountability has by now been interpreted in ways which are different enough from one another to have permitted a certain ambiguity to creep into the notion in its present use within the educational community. The principal purpose of this report is, therefore, to try to set forth some clearer statement of what the idea of…

  8. Fiscal Accounting Manual.

    ERIC Educational Resources Information Center

    California State Dept. of Housing and Community Development, Sacramento. Indian Assistance Program.

    Written in simple, easy to understand form, the manual provides a vehicle for the untrained person in bookkeeping to control funds received from grants for Indian Tribal Councils and Indian organizations. The method used to control grants (federal, state, or private) is fund accounting, designed to organize rendering services on a non-profit…

  9. Institutional Accountability Report, 2000.

    ERIC Educational Resources Information Center

    Santa Fe Community Coll., Gainesville, FL. Office of Institutional Research and Planning.

    This document discusses Santa Fe Community College's (SFCC) (Florida) five accountability measures. The type of data available provided on these measures is as follows: (1) District High School Enrollment Report and Retention and Success Rate Report; (2) Associate of Arts Degree Transfer Performance in the State University System; (3) Licensure…

  10. Accounting 202, 302.

    ERIC Educational Resources Information Center

    Manitoba Dept. of Education, Winnipeg.

    This teaching guide consists of guidelines for conducting two secondary-level introductory accounting courses. Intended for vocational business education students, the courses are designed to introduce financial principles and practices important to personal and business life, to promote development of clerical and bookkeeping skills sufficient…

  11. Educational Accounting Procedures.

    ERIC Educational Resources Information Center

    Tidwell, Sam B.

    This chapter of "Principles of School Business Management" reviews the functions, procedures, and reports with which school business officials must be familiar in order to interpret and make decisions regarding the school district's financial position. Among the accounting functions discussed are financial management, internal auditing,…

  12. Planning for Accountability.

    ERIC Educational Resources Information Center

    Cuneo, Tim; Bell, Shareen; Welsh-Gray, Carol

    1999-01-01

    Through its Challenge 2000 program, Joint Venture: Silicon Valley Network's 21st Century Education Initiative has been working with K-12 schools to improve student performance in literature, math, and science. Clearly stated standards, appropriate assessments, formal monitoring, critical friends, and systemwide accountability are keys to success.…

  13. Community Accountability Conferencing.

    ERIC Educational Resources Information Center

    Thorsborne, Margaret

    Community Accountability Conferencing (CAC) was first introduced in Queensland, Australia schools in early 1994 after a serious assault in the school community. Some family members, students, and staff were dissatisfied with the solution of suspending the offenders. Seeking an alternative, comprehensive intervention strategy, the school community…

  14. Legal responsibility and accountability.

    PubMed

    Cox, Chris

    2010-06-01

    Shifting boundaries in healthcare roles have led to anxiety among some nurses about their legal responsibilities and accountabilities. This is partly because of a lack of education about legal principles that underpin healthcare delivery. This article explains the law in terms of standards of care, duty of care, vicarious liability and indemnity insurance.

  15. The New Accountability.

    ERIC Educational Resources Information Center

    Tucker, Marc S.; Clark, Charles S.

    1999-01-01

    The only way public schools can keep up with the economic facts of life is by learning how to educate virtually all students to a much higher standard at current costs. Three contemporary models of school accountability are the systems used in Kentucky, Chicago, and Edmonton, Canada. (MLF)

  16. Professional Capital as Accountability

    ERIC Educational Resources Information Center

    Fullan, Michael; Rincón-Gallardo, Santiago; Hargreaves, Andy

    2015-01-01

    This paper seeks to clarify and spells out the responsibilities of policy makers to create the conditions for an effective accountability system that produces substantial improvements in student learning, strengthens the teaching profession, and provides transparency of results to the public. The authors point out that U.S. policy makers will need…

  17. Planning for Accountability.

    ERIC Educational Resources Information Center

    Cuneo, Tim; Bell, Shareen; Welsh-Gray, Carol

    1999-01-01

    Through its Challenge 2000 program, Joint Venture: Silicon Valley Network's 21st Century Education Initiative has been working with K-12 schools to improve student performance in literature, math, and science. Clearly stated standards, appropriate assessments, formal monitoring, critical friends, and systemwide accountability are keys to success.…

  18. Democracy, Accountability, and Education

    ERIC Educational Resources Information Center

    Levinson, Meira

    2011-01-01

    Educational standards, assessments, and accountability systems are of immense political moment around the world. But there is no developed theory exploring the role that these systems should play within a democratic polity in particular. On the one hand, well-designed standards are public goods, supported by assessment and accountability…

  19. Making Accountability Really Count

    ERIC Educational Resources Information Center

    Resnick, Lauren B.

    2006-01-01

    Standards-based education has now reached a stage where it is possible to evaluate its overall effectiveness. Several earlier papers in the special issue of "Educational Measurement: Issues and Practice" on "Test Scores and State Accountability" (Volume 24, Number 4) examined specific state policies and their effects on schools…

  20. Viewpoints on Accountability.

    ERIC Educational Resources Information Center

    Educational Innovators Press, Tucson, AZ.

    This booklet contains five papers which examine the activities, successes, and pitfalls encountered by educators who are introducing accountability techniques into instructional programs where they did not exist in the past. The papers are based on actual programs and offer possible solutions in the areas considered, which are 1) performance…

  1. Democracy, Accountability, and Education

    ERIC Educational Resources Information Center

    Levinson, Meira

    2011-01-01

    Educational standards, assessments, and accountability systems are of immense political moment around the world. But there is no developed theory exploring the role that these systems should play within a democratic polity in particular. On the one hand, well-designed standards are public goods, supported by assessment and accountability…

  2. Curtail Accountability, Cultivate Attainability

    ERIC Educational Resources Information Center

    Wraga, William G.

    2011-01-01

    The current test-driven accountability movement, codified in the No Child Left Behind Act of 2001 ([NCLB] 2002), was a misguided idea that will have the effect not of improving the education of children and youth, but of indicting the public school system of the United States. To improve education in the United States, politicians, policy makers,…

  3. Student Attendance Accounting Manual.

    ERIC Educational Resources Information Center

    Freitas, Joseph M.

    In response to state legislation authorizing procedures for changes in academic calendars and measurement of student workload in California community colleges, this manual from the Chancellor's Office provides guidelines for student attendance accounting. Chapter 1 explains general items such as the academic calendar, admissions policies, student…

  4. Accountability in Hawaii.

    ERIC Educational Resources Information Center

    Min, Kellet I.

    After describing recent school reforms in Hawaii, this paper discusses the state's efforts to ensure greater accountability and to deal with two issues: student evaluation and the measurement of indicators used in state-by-state comparisons. During the past few years, Hawaii has been involved in many reform initiatives, including implementating…

  5. Full Accounting for Curriculum.

    ERIC Educational Resources Information Center

    Paddock, Marie-Louise

    1988-01-01

    Given the curriculum's importance in the educational process, curriculum evaluation should be considered as essential as a district financial audit. When Fenwick English conducted a 1979 curriculum audit of Columbus, Ohio, schools, the accounting firm encountered numerous problems concerning development, review, and management practices. Planning…

  6. Student Attendance Accounting Manual.

    ERIC Educational Resources Information Center

    Freitas, Joseph M.

    In response to state legislation authorizing procedures for changes in academic calendars and measurement of student workload in California community colleges, this manual from the Chancellor's Office provides guidelines for student attendance accounting. Chapter 1 explains general items such as the academic calendar, admissions policies, student…

  7. Higher Education Accountability Plans

    ERIC Educational Resources Information Center

    Washington Higher Education Coordinating Board, 2003

    2003-01-01

    Washington state's public four-year universities and college have submitted their 2003-05 accountability plans to the Higher Education Coordinating Board (HECB). The state operating budget directs the Board to review these plans and set biennial performance targets for each institution. For 2003-05, the four-year institutions are reporting on a…

  8. Accounting 202, 302.

    ERIC Educational Resources Information Center

    Manitoba Dept. of Education, Winnipeg.

    This teaching guide consists of guidelines for conducting two secondary-level introductory accounting courses. Intended for vocational business education students, the courses are designed to introduce financial principles and practices important to personal and business life, to promote development of clerical and bookkeeping skills sufficient…

  9. Curtail Accountability, Cultivate Attainability

    ERIC Educational Resources Information Center

    Wraga, William G.

    2011-01-01

    The current test-driven accountability movement, codified in the No Child Left Behind Act of 2001 ([NCLB] 2002), was a misguided idea that will have the effect not of improving the education of children and youth, but of indicting the public school system of the United States. To improve education in the United States, politicians, policy makers,…

  10. Excel in the Accounting Curriculum: Perceptions from Accounting Professors

    ERIC Educational Resources Information Center

    Ramachandran Rackliffe, Usha; Ragland, Linda

    2016-01-01

    Public accounting firms emphasize the importance of accounting graduates being proficient in Excel. Since many accounting graduates often aspire to work in public accounting, a question arises as to whether there should be an emphasis on Excel in accounting education. The purpose of this paper is to specifically look at this issue by examining…

  11. 18 CFR 367.1420 - Account 142, Customer accounts receivable.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 142, Customer... GAS ACT Balance Sheet Chart of Accounts Current and Accrued Assets § 367.1420 Account 142, Customer accounts receivable. (a) This account must include amounts due from customers for service, and...

  12. A Pariah Profession? Some Student Perceptions of Accounting and Accountancy.

    ERIC Educational Resources Information Center

    Fisher, Roy; Murphy, Vivienne

    1995-01-01

    Existing literature and a survey of 106 undergraduate accounting students in the United Kingdom were analyzed for perceptions of the accounting profession and the academic discipline of accounting. Results suggest that among accounting and nonaccounting students alike, there exist coexisting perceptions of accounting as having high status and low…

  13. A Pariah Profession? Some Student Perceptions of Accounting and Accountancy.

    ERIC Educational Resources Information Center

    Fisher, Roy; Murphy, Vivienne

    1995-01-01

    Existing literature and a survey of 106 undergraduate accounting students in the United Kingdom were analyzed for perceptions of the accounting profession and the academic discipline of accounting. Results suggest that among accounting and nonaccounting students alike, there exist coexisting perceptions of accounting as having high status and low…

  14. Excel in the Accounting Curriculum: Perceptions from Accounting Professors

    ERIC Educational Resources Information Center

    Ramachandran Rackliffe, Usha; Ragland, Linda

    2016-01-01

    Public accounting firms emphasize the importance of accounting graduates being proficient in Excel. Since many accounting graduates often aspire to work in public accounting, a question arises as to whether there should be an emphasis on Excel in accounting education. The purpose of this paper is to specifically look at this issue by examining…

  15. MATERIAL CONTROL ACCOUNTING INMM

    SciTech Connect

    Hasty, T.

    2009-06-14

    Since 1996, the Mining and Chemical Combine (MCC - formerly known as K-26), and the United States Department of Energy (DOE) have been cooperating under the cooperative Nuclear Material Protection, Control and Accounting (MPC&A) Program between the Russian Federation and the U.S. Governments. Since MCC continues to operate a reactor for steam and electricity production for the site and city of Zheleznogorsk which results in production of the weapons grade plutonium, one of the goals of the MPC&A program is to support implementation of an expanded comprehensive nuclear material control and accounting (MC&A) program. To date MCC has completed upgrades identified in the initial gap analysis and documented in the site MC&A Plan and is implementing additional upgrades identified during an update to the gap analysis. The scope of these upgrades includes implementation of MCC organization structure relating to MC&A, establishing material balance area structure for special nuclear materials (SNM) storage and bulk processing areas, and material control functions including SNM portal monitors at target locations. Material accounting function upgrades include enhancements in the conduct of physical inventories, limit of error inventory difference procedure enhancements, implementation of basic computerized accounting system for four SNM storage areas, implementation of measurement equipment for improved accountability reporting, and both new and revised site-level MC&A procedures. This paper will discuss the implementation of MC&A upgrades at MCC based on the requirements established in the comprehensive MC&A plan developed by the Mining and Chemical Combine as part of the MPC&A Program.

  16. Carbon dioxide transport through membranes.

    PubMed

    Missner, Andreas; Kügler, Philipp; Saparov, Sapar M; Sommer, Klaus; Mathai, John C; Zeidel, Mark L; Pohl, Peter

    2008-09-12

    Several membrane channels, like aquaporin-1 (AQP1) and the RhAG protein of the rhesus complex, were hypothesized to be of physiological relevance for CO(2) transport. However, the underlying assumption that the lipid matrix imposes a significant barrier to CO(2) diffusion was never confirmed experimentally. Here we have monitored transmembrane CO(2) flux (J(CO2)) by imposing a CO(2) concentration gradient across planar lipid bilayers and detecting the resulting small pH shift in the immediate membrane vicinity. An analytical model, which accounts for the presence of both carbonic anhydrase and buffer molecules, was fitted to the experimental pH profiles using inverse problems techniques. At pH 7.4, the model revealed that J(CO2) was entirely rate-limited by near-membrane unstirred layers (USL), which act as diffusional barriers in series with the membrane. Membrane tightening by sphingomyelin and cholesterol did not alter J(CO2) confirming that membrane resistance was comparatively small. In contrast, a pH-induced shift of the CO(2) hydration-dehydration equilibrium resulted in a relative membrane contribution of about 15% to the total resistance (pH 9.6). Under these conditions, a membrane CO(2) permeability (3.2 +/- 1.6 cm/s) was estimated. It indicates that cellular CO(2) uptake (pH 7.4) is always USL-limited, because the USL size always exceeds 1 mum. Consequently, facilitation of CO(2) transport by AQP1, RhAG, or any other protein is highly unlikely. The conclusion was confirmed by the observation that CO(2) permeability of epithelial cell monolayers was always the same whether AQP1 was overexpressed in both the apical and basolateral membranes or not.

  17. Organic Electrolyte Permselective Membranes.

    DTIC Science & Technology

    ORGANIC SOLVENTS), (*STORAGE BATTERIES, (*BATTERY SEPARATORS, MEMBRANES ), (* MEMBRANES , TRANSPORT PROPERTIES), LITHIUM, COPPER COMPOUNDS, DIFFUSION, CHLORIDES, IONS, ELECTRODIALYSIS , ION EXCHANGE RESINS.

  18. Bridging the accountability gap.

    PubMed

    Johnson, J E

    1991-01-01

    Accountability for patient care is a responsibility shared by nursing and hospital administration. Inherent in professional nursing is the responsibility for the achievement of patient outcomes, while administrators assume more indirect responsibilities related to managerial functions, strategic planning and legal obligations. Historically, the poor communication and conflict between these groups have been a barrier to achieving true institutional accountability for patient care. Collaboration rather than conflict can be promoted in health care institutions by making organizational changes that promote communication and clarify ambiguities in job responsibilities. Such changes include redefining the nurse's job to reflect its scope and purpose; integrating nursing into the hospital environment via regular forums for information exchange and participation in hospital committees; considering that the delegation of patient care is implicit in nursing practice and patient-care management; and strengthening the nursing work force by improving compensation and benefits packages for nurses.

  19. Managing global accounts.

    PubMed

    Yip, George S; Bink, Audrey J M

    2007-09-01

    Global account management--which treats a multinational customer's operations as one integrated account, with coherent terms for pricing, product specifications, and service--has proliferated over the past decade. Yet according to the authors' research, only about a third of the suppliers that have offered GAM are pleased with the results. The unhappy majority may be suffering from confusion about when, how, and to whom to provide it. Yip, the director of research and innovation at Capgemini, and Bink, the head of marketing communications at Uxbridge College, have found that GAM can improve customer satisfaction by 20% or more and can raise both profits and revenues by at least 15% within just a few years of its introduction. They provide guidelines to help companies achieve similar results. The first steps are determining whether your products or services are appropriate for GAM, whether your customers want such a program, whether those customers are crucial to your strategy, and how GAM might affect your competitive advantage. If moving forward makes sense, the authors' exhibit, "A Scorecard for Selecting Global Accounts," can help you target the right customers. The final step is deciding which of three basic forms to offer: coordination GAM (in which national operations remain relatively strong), control GAM (in which the global operation and the national operations are fairly balanced), and separate GAM (in which a new business unit has total responsibility for global accounts). Given the difficulty and expense of providing multiple varieties, the vast majority of companies should initially customize just one---and they should be careful not to start with a choice that is too ambitious for either themselves or their customers to handle.

  20. First-Person Accounts.

    ERIC Educational Resources Information Center

    Gribs, H.; And Others

    1995-01-01

    Personal accounts describe the lives of 2 individuals with deaf-blindness, one an 87-year-old woman who was deaf from birth and became totally blind over a 50-year period and the other of a woman who became deaf-blind as a result of a fever at the age of 7. Managing activities of daily life and experiencing sensory hallucinations are among topics…

  1. Integrated Cost Accounting System.

    DTIC Science & Technology

    1992-07-27

    few other companies. Harvard Business Review contained articles explaining the ideas behind the new costing methods and examples of applications...technical report. Peter Drucker in an article in Harvard Business Review ’carefully explains that accounting must change in response to the changes in...Kaplan in a Harvard Business Review article develop the idea of four levels of activities: facility sustaining activities; product-sustaining activities

  2. Hospitals' Internal Accountability

    PubMed Central

    Kraetschmer, Nancy; Jass, Janak; Woodman, Cheryl; Koo, Irene; Kromm, Seija K.; Deber, Raisa B.

    2014-01-01

    This study aimed to enhance understanding of the dimensions of accountability captured and not captured in acute care hospitals in Ontario, Canada. Based on an Ontario-wide survey and follow-up interviews with three acute care hospitals in the Greater Toronto Area, we found that the two dominant dimensions of hospital accountability being reported are financial and quality performance. These two dimensions drove both internal and external reporting. Hospitals' internal reports typically included performance measures that were required or mandated in external reports. Although respondents saw reporting as a valuable mechanism for hospitals and the health system to monitor and track progress against desired outcomes, multiple challenges with current reporting requirements were communicated, including the following: 58% of survey respondents indicated that performance-reporting resources were insufficient; manual data capture and performance reporting were prevalent, with the majority of hospitals lacking sophisticated tools or technology to effectively capture, analyze and report performance data; hospitals tended to focus on those processes and outcomes with high measurability; and 53% of respondents indicated that valuable cross-system accountability, performance measures or both were not captured by current reporting requirements. PMID:25305387

  3. Methods applicable to membrane nanodomain studies?

    PubMed

    Ashrafzadeh, Parham; Parmryd, Ingela

    2015-01-01

    Membrane nanodomains are dynamic liquid entities surrounded by another type of dynamic liquid. Diffusion can take place inside, around and in and out of the domains, and membrane components therefore continuously shift between domains and their surroundings. In the plasma membrane, there is the further complexity of links between membrane lipids and proteins both to the extracellular matrix and to intracellular proteins such as actin filaments. In addition, new membrane components are continuously delivered and old ones removed. On top of this, cells move. Taking all of this into account imposes great methodological challenges, and in the present chapter we discuss some methods that are currently used for membrane nanodomain studies, what information they can provide and their weaknesses.

  4. Inflation Accounting Methods and their Effectiveness.

    DTIC Science & Technology

    accounting and current cost accounting are explained as the major inflation accounting methods. Inflation accounting standards announced in the United...inflation accounting, constant purchasing power accounting, constant dollar accounting, current cost accounting , current value.

  5. Omniphobic Membrane for Robust Membrane Distillation

    SciTech Connect

    Lin, SH; Nejati, S; Boo, C; Hu, YX; Osuji, CO; Ehmelech, M

    2014-11-01

    In this work, we fabricate an omniphobic microporous membrane for membrane distillation (MD) by modifying a hydrophilic glass fiber membrane with silica nanoparticles followed by surface fluorination and polymer coating. The modified glass fiber membrane exhibits an anti-wetting property not only against water but also against low surface tension organic solvents that easily wet a hydrophobic polytetrafluoroethylene (PTFE) membrane that is commonly used in MD applications. By comparing the performance of the PTFE and omniphobic membranes in direct contact MD experiments in the presence of a surfactant (sodium dodecyl sulfate, SDS), we show that SDS wets the hydrophobic PTFE membrane but not the omniphobic membrane. Our results suggest that omniphobic membranes are critical for MD applications with feed waters containing surface active species, such as oil and gas produced water, to prevent membrane pore wetting.

  6. Materials for next-generation molecularly selective synthetic membranes

    NASA Astrophysics Data System (ADS)

    Koros, William J.; Zhang, Chen

    2017-03-01

    Materials research is key to enable synthetic membranes for large-scale, energy-efficient molecular separations. Materials with rigid, engineered pore structures add an additional degree of freedom to create advanced membranes by providing entropically moderated selectivities. Scalability -- the capability to efficiently and economically pack membranes into practical modules -- is a critical yet often neglected factor to take into account for membrane materials screening. In this Progress Article, we highlight continuing developments and identify future opportunities in scalable membrane materials based on these rigid features, for both gas and liquid phase applications. These advanced materials open the door to a new generation of membrane processes beyond existing materials and approaches.

  7. Materials for next-generation molecularly selective synthetic membranes.

    PubMed

    Koros, William J; Zhang, Chen

    2017-03-01

    Materials research is key to enable synthetic membranes for large-scale, energy-efficient molecular separations. Materials with rigid, engineered pore structures add an additional degree of freedom to create advanced membranes by providing entropically moderated selectivities. Scalability - the capability to efficiently and economically pack membranes into practical modules - is a critical yet often neglected factor to take into account for membrane materials screening. In this Progress Article, we highlight continuing developments and identify future opportunities in scalable membrane materials based on these rigid features, for both gas and liquid phase applications. These advanced materials open the door to a new generation of membrane processes beyond existing materials and approaches.

  8. Osmotic pressure effect on membrane fouling in a submerged anaerobic membrane bioreactor and its experimental verification.

    PubMed

    Chen, Jianrong; Zhang, Meijia; Wang, Aijun; Lin, Hongjun; Hong, Huachang; Lu, Xiaofeng

    2012-12-01

    A laboratory-scale submerged anaerobic membrane bioreactor (SAnMBR) treating sewage was used to investigate the membrane fouling mechanism. Characterization of cake layer formed on membrane surface showed that cake layer was hydrated, rich of extracellular polymeric substances (EPS) and negative charged with the charge density of 0.21-0.46 meq/kg MLSS. Detailed analysis revealed a new membrane fouling mechanism, osmotic pressure during cake layer filtration process due to the interception of ions. An osmotic pressure model was then developed to elaborate the existence of osmotic pressure and to estimate the contribution of osmotic pressure to membrane fouling. The calculated results showed that osmotic pressure accounted for the largest fraction of total operation pressure, indicating that osmotic pressure generated by the retained ions was one of the major mechanisms responsible for membrane fouling problem in MBRs. These findings provided a new insight into membrane fouling in MBRs. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Demonstrating marketing accountability.

    PubMed

    Gombeski, William R; Britt, Jason; Taylor, Jan; Riggs, Karen; Wray, Tanya; Adkins, Wanda; Springate, Suzanne

    2008-01-01

    Pressure on health care marketers to demonstrate effectiveness of their strategies and show their contribution to organizational goals is growing. A seven-tiered model based on the concepts of structure (having the right people, systems), process (doing the right things in the right way), and outcomes (results) is discussed. Examples of measures for each tier are provided and the benefits of using the model as a tool for measuring, organizing, tracking, and communicating appropriate information are provided. The model also provides a framework for helping management understand marketing's value and can serve as a vehicle for demonstrating marketing accountability.

  10. Performance and Accountability Report

    NASA Technical Reports Server (NTRS)

    2003-01-01

    The NASA Fiscal Year 2002 Performance and Accountability Report is presented. Over the past year, significant changes have been implemented to greatly improve NASA's management while continuing to break new ground in science and technology. Excellent progress has been made in implementing the President's Management Agenda. NASA is leading the government in its implementation of the five government-wide initiatives. NASA received an unqualified audit opinion on FY 2002 financial statements. The vast majority of performance goals have been achieved, furthering each area of NASA's mission. The contents include: 1) NASA Vision and Mission; 2) Management's Discussion and Analysis; 3) Performance; and 4) Financial.

  11. Computerised Accounting Software; A Curriculum That Enhances an Accounting Programme

    ERIC Educational Resources Information Center

    Machera, Robert P.; Machera, Precious C.

    2017-01-01

    There has been an outcry in commerce and industry about students who fail to perform in the accounting department due to lack of "practical accounting skills". It is from this background that the researchers were motivated to investigate the impact of a Computerised Accounting Software Curriculum that enhances an Accounting Programme. At…

  12. 76 FR 53378 - Cost Accounting Standards: Accounting for Insurance Costs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... BUDGET Office of Federal Procurement Policy 48 CFR Part 9904 Cost Accounting Standards: Accounting for Insurance Costs AGENCY: Cost Accounting Standards Board (Board), Office of Federal Procurement Policy (OFPP... Office of Federal Procurement Policy (OFPP), Cost Accounting Standards (CAS) Board, is providing public...

  13. New Frontiers: Training Forensic Accountants within the Accounting Program

    ERIC Educational Resources Information Center

    Ramaswamy, Vinita

    2007-01-01

    Accountants have recently been subject to very unpleasant publicity following the collapse of Enron and other major companies. There has been a plethora of accounting failures and accounting restatements of falsified earnings, with litigations and prosecutions taking place every day. As the FASB struggles to tighten the loopholes in accounting,…

  14. 18 CFR 367.9040 - Account 904, Uncollectible accounts.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Account 904, Uncollectible accounts. 367.9040 Section 367.9040 Conservation of Power and Water Resources FEDERAL ENERGY... accounts. This account must be charged with amounts sufficient to provide for losses from uncollectible...

  15. 18 CFR 367.9040 - Account 904, Uncollectible accounts.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 904, Uncollectible accounts. 367.9040 Section 367.9040 Conservation of Power and Water Resources FEDERAL ENERGY... accounts. This account must be charged with amounts sufficient to provide for losses from uncollectible...

  16. 18 CFR 367.9040 - Account 904, Uncollectible accounts.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Account 904, Uncollectible accounts. 367.9040 Section 367.9040 Conservation of Power and Water Resources FEDERAL ENERGY... accounts. This account must be charged with amounts sufficient to provide for losses from uncollectible...

  17. 18 CFR 367.9040 - Account 904, Uncollectible accounts.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Account 904, Uncollectible accounts. 367.9040 Section 367.9040 Conservation of Power and Water Resources FEDERAL ENERGY... accounts. This account must be charged with amounts sufficient to provide for losses from uncollectible...

  18. New Frontiers: Training Forensic Accountants within the Accounting Program

    ERIC Educational Resources Information Center

    Ramaswamy, Vinita

    2007-01-01

    Accountants have recently been subject to very unpleasant publicity following the collapse of Enron and other major companies. There has been a plethora of accounting failures and accounting restatements of falsified earnings, with litigations and prosecutions taking place every day. As the FASB struggles to tighten the loopholes in accounting,…

  19. The Integration of Behavioral Accounting in Undergraduate Accounting Curricula.

    ERIC Educational Resources Information Center

    Buchanan, Phillip G.; Cao, Le Thi

    1986-01-01

    The study reported here is part of a continuing project with the goal of determining the place of behavioral accounting in the accounting curricula. While the first two studies focused on the graduate accounting curricula and the practitioners' opinions on the subject, this study concentrates on the behavioral accounting content of undergraduate…

  20. Oxidation of Pu(III) by nitric acid in tri-n-butyl phosphate solutions. Part II. Chemical methods for the suppression of oxidation to improve plutonium separation in contactor operation

    SciTech Connect

    Sze, Y.K.; Gosselin, J.A.

    1983-12-01

    A systematic method has been used to screen a number of potential stabilizers (holding reductants) for Pu(III) in tri-n-butyl phosphate/diluent solutions used in irradiated fuel reprocessing systems. The conditions assumed were similar to those used in solvent extraction contactor operations. Of the reagents tested, oximes as a group appeared to be very effective. Acetaldoxime, in particular, was selected for extensive tests and was used as a Pu(III) stabilizer, in both the aqueous and organic phases, in contactor runs for plutonium partition from thorium and uranium. In the best results, the plutonium loss to the thorium/uranium stream was 2.8 X 10/sup -5/ g/l or 0.0046%; without using acetaldoxime, the loss was 12%. Rates of plutonium reduction in 1.5 M nitric acid have been compared for a number of reducing agents under identical conditions. Some derivatives of hydroxylamine were found to be much more effective than hydroxylamine itself.

  1. Physical basis of some membrane shaping mechanisms

    PubMed Central

    2016-01-01

    In vesicular transport pathways, membrane proteins and lipids are internalized, externalized or transported within cells, not by bulk diffusion of single molecules, but embedded in the membrane of small vesicles or thin tubules. The formation of these ‘transport carriers’ follows sequential events: membrane bending, fission from the donor compartment, transport and eventually fusion with the acceptor membrane. A similar sequence is involved during the internalization of drug or gene carriers inside cells. These membrane-shaping events are generally mediated by proteins binding to membranes. The mechanisms behind these biological processes are actively studied both in the context of cell biology and biophysics. Bin/amphiphysin/Rvs (BAR) domain proteins are ideally suited for illustrating how simple soft matter principles can account for membrane deformation by proteins. We review here some experimental methods and corresponding theoretical models to measure how these proteins affect the mechanics and the shape of membranes. In more detail, we show how an experimental method employing optical tweezers to pull a tube from a giant vesicle may give important quantitative insights into the mechanism by which proteins sense and generate membrane curvature and the mechanism of membrane scission. This article is part of the themed issue ‘Soft interfacial materials: from fundamentals to formulation’. PMID:27298443

  2. Optimizing internal structure of membrane filters

    NASA Astrophysics Data System (ADS)

    Cummings, Linda; Sanaei, Pejman

    2016-11-01

    Membrane filters are in widespread use, and manufacturers have considerable interest in improving their performance, in terms of particle retention properties, and total throughput over the filter lifetime. In this regard, it has long been known that membrane properties should not be uniform over the membrane depth; rather, membrane permeability should decrease in the direction of flow. While much research effort has been focused on investigating favorable membrane permeability gradients, this work has been largely empirical in nature. We present a simple, first-principles model for flow through and fouling of a membrane filter, accounting for permeability gradients via variable pore size. Our model accounts for two fouling modes: sieving; and particle adsorption within pores. For filtration driven by a fixed pressure drop, flux through the membrane eventually goes to zero, as fouling occurs and pores close. We address issues of filter performance as the internal pore structure is varied, by comparing the total throughput obtained with equal-resistance membranes. Within certain classes of pore profiles we are able to find the optimum pore profile that maximizes total throughput over the filter lifetime, while maintaining acceptable particle removal from the feed. Partial support from NSF DMS 1261596 is gratefully acknowledged.

  3. Anion permselective membrane

    NASA Technical Reports Server (NTRS)

    Hodgdon, R. B.; Waite, W. A.

    1980-01-01

    The efforts on the synthesis of polymer anion redox membranes were mainly concentrated in two areas, membrane development and membrane fabrication. Membrane development covered the preparation and evaluation of experimental membranes systems with improved resistance stability and/or lower permeability. Membrane fabrication covered the laboratory scale production of prime candidate membranes in quantities of up to two hundred and sizes up to 18 inches x 18 inches (46 cm x 46 cm). These small (10 in x 11 in) and medium sized membranes were mainly for assembly into multicell units. Improvements in processing procedures and techniques for preparing such membrane sets lifted yields to over 90 percent.

  4. Where Are the Accounting Professors?

    ERIC Educational Resources Information Center

    Chang, Jui-Chin; Sun, Huey-Lian

    2008-01-01

    Accounting education is facing a crisis of shortage of accounting faculty. This study discusses the reasons behind the shortage and offers suggestions to increase the supply of accounting faculty. Our suggestions are as followings. First, educators should begin promoting accounting academia as one of the career choices to undergraduate and…

  5. Revamping High School Accounting Courses.

    ERIC Educational Resources Information Center

    Bittner, Joseph

    2002-01-01

    Provides ideas for updating accounting courses: convert to semester length; focus on financial reporting/analysis, financial statements, the accounting cycle; turn textbook exercises into practice sets for the accounting cycle; teach about corporate accounting; and address individual line items on financial statements. (SK)

  6. Accountability and the New Essentials.

    ERIC Educational Resources Information Center

    Dowd, Steven B.

    The current emphasis in education on accountability is tending toward "push-button accountability." The challenge is to evaluate access and retention as well as other educationally relevant goals to define "quality" or "accountability." In higher education, accountability should be proven through assessment and should consist of proof that what…

  7. Automated Accounting. Payroll. Instructor Module.

    ERIC Educational Resources Information Center

    Moses, Duane R.

    This teacher's guide was developed to assist business instructors using Dac Easy Accounting Payroll Version 3.0 edition software in their accounting programs. The module contains assignment sheets and job sheets designed to enable students to master competencies identified in the area of automated accounting--payroll. Basic accounting skills are…

  8. Accountability and the New Essentials.

    ERIC Educational Resources Information Center

    Dowd, Steven B.

    The current emphasis in education on accountability is tending toward "push-button accountability." The challenge is to evaluate access and retention as well as other educationally relevant goals to define "quality" or "accountability." In higher education, accountability should be proven through assessment and should consist of proof that what…

  9. Where Are the Accounting Professors?

    ERIC Educational Resources Information Center

    Chang, Jui-Chin; Sun, Huey-Lian

    2008-01-01

    Accounting education is facing a crisis of shortage of accounting faculty. This study discusses the reasons behind the shortage and offers suggestions to increase the supply of accounting faculty. Our suggestions are as followings. First, educators should begin promoting accounting academia as one of the career choices to undergraduate and…

  10. Selecting a Roof Membrane.

    ERIC Educational Resources Information Center

    Waldron, Larry W.

    1990-01-01

    Offers a brief synopsis of the unique characteristics of the following roof membranes: (1) built-up roofing; (2) elastoplastic membranes; (3) modified bitumen membranes; (4) liquid applied membranes; and (5) metal roofing. A chart compares the characteristics of the raw membranes only. (MLF)

  11. Magnetic Membrane System

    DOEpatents

    McElfresh, Michael W.; ; Lucas, Matthew S.

    2004-12-30

    The present invention provides a membrane with magnetic particles. In one embodiment the membrane is created by mixing particles in a non-magnetic base. The membrane may act as an actuator, a sensor, a pump, a valve, or other device. A magnet is operatively connected to the membrane. The magnet acts on and changes the shape of the membrane.

  12. Pain: A Statistical Account

    PubMed Central

    Thacker, Michael A.; Moseley, G. Lorimer

    2017-01-01

    Perception is seen as a process that utilises partial and noisy information to construct a coherent understanding of the world. Here we argue that the experience of pain is no different; it is based on incomplete, multimodal information, which is used to estimate potential bodily threat. We outline a Bayesian inference model, incorporating the key components of cue combination, causal inference, and temporal integration, which highlights the statistical problems in everyday perception. It is from this platform that we are able to review the pain literature, providing evidence from experimental, acute, and persistent phenomena to demonstrate the advantages of adopting a statistical account in pain. Our probabilistic conceptualisation suggests a principles-based view of pain, explaining a broad range of experimental and clinical findings and making testable predictions. PMID:28081134

  13. Automated attendance accounting system

    NASA Technical Reports Server (NTRS)

    Chapman, C. P. (Inventor)

    1973-01-01

    An automated accounting system useful for applying data to a computer from any or all of a multiplicity of data terminals is disclosed. The system essentially includes a preselected number of data terminals which are each adapted to convert data words of decimal form to another form, i.e., binary, usable with the computer. Each data terminal may take the form of a keyboard unit having a number of depressable buttons or switches corresponding to selected data digits and/or function digits. A bank of data buffers, one of which is associated with each data terminal, is provided as a temporary storage. Data from the terminals is applied to the data buffers on a digit by digit basis for transfer via a multiplexer to the computer.

  14. Financial accounting for radiology executives.

    PubMed

    Seidmann, Abraham; Mehta, Tushar

    2005-03-01

    The authors review the role of financial accounting information from the perspective of a radiology executive. They begin by introducing the role of pro forma statements. They discuss the fundamental concepts of accounting, including the matching principle and accrual accounting. The authors then explore the use of financial accounting information in making investment decisions in diagnostic medical imaging. The paper focuses on critically evaluating the benefits and limitations of financial accounting for decision making in a radiology practice.

  15. Membrane Systems in Cyanobacteria

    SciTech Connect

    Liberton, Michelle L.; Pakrasi, Himadri B.

    2008-01-01

    Cyanobacteria are photosynthetic prokaryotes with highly differentiated membrane systems. In addition to a Gram-negative-type cell envelope with plasma membrane and outer membrane separated by a periplasmic space, cyanobacteria have an internal system of thylakoid membranes where the fully functional electron transfer chains of photosynthesis and respiration reside. The presence of different membrane systems lends these cells a unique complexity among bacteria. Cyanobacteria must be able to reorganize the membranes, synthesize new membrane lipids, and properly target proteins to the correct membrane system. The outer membrane, plasma membrane, and thylakoid membranes each have specialized roles in the cyanobacterial cell. Understanding the organization, functionality, protein composition and dynamics of the membrane systems remains a great challenge in cyanobacterial cell biology.

  16. Tethered bilayer lipid membranes (tBLMs): interest and applications for biological membrane investigations.

    PubMed

    Rebaud, Samuel; Maniti, Ofelia; Girard-Egrot, Agnès P

    2014-12-01

    Biological membranes play a central role in the biology of the cell. They are not only the hydrophobic barrier allowing separation between two water soluble compartments but also a supra-molecular entity that has vital structural functions. Notably, they are involved in many exchange processes between the outside and inside cellular spaces. Accounting for the complexity of cell membranes, reliable models are needed to acquire current knowledge of the molecular processes occurring in membranes. To simplify the investigation of lipid/protein interactions, the use of biomimetic membranes is an approach that allows manipulation of the lipid composition of specific domains and/or the protein composition, and the evaluation of the reciprocal effects. Since the middle of the 80's, lipid bilayer membranes have been constantly developed as models of biological membranes with the ultimate goal to reincorporate membrane proteins for their functional investigation. In this review, after a brief description of the planar lipid bilayers as biomimetic membrane models, we will focus on the construction of the tethered Bilayer Lipid Membranes, the most promising model for efficient membrane protein reconstitution and investigation of molecular processes occurring in cell membranes. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Gas transport across hyperthin membranes.

    PubMed

    Wang, Minghui; Janout, Vaclav; Regen, Steven L

    2013-12-17

    The use of organic polymeric membranes to separate gaseous mixtures provides an attractive alternative to other methods such as selective adsorption and cryogenic distillation. The primary advantages of membrane-based separations are their relative energy efficiency and lower costs. Because the flux of a gas across a membrane is inversely proportional to the membrane's thickness, this method relies on fabricating membranes that are as thin as possible. However, as researchers have tried to produce "hyperthin" membranes (less than 100 nm), these membranes often form defects and lose their permeation selectivity. In this Account, we review some of the progress in our laboratories at Lehigh University to create hyperthin membranes with high permeation selectivities. We focus special attention on gaseous permeants that are relevant for the production of clean energy (H2 and CO2 formed from CH4) and the reduction of global warming (CO2 and N2, the major components of flue gas). Our studies make extensive use of Langmuir-Blodgett (LB) methods and porous surfactants derived from calix[6]arenes. We specially designed each surfactant to form cohesive monolayers and multilayers, and we introduced a "gluing" technique, where we cross-link porous surfactants containing quaternary ammonium groups ionically with polymeric counterions. Using ellipsometry, atomic force microscopy, X-ray photoelectron spectroscopy, monolayer isotherm, surface viscosity, and permeation measurements, we have characterized these hyperthin films. While molecular sieving appears to make a significant contribution to the permeation selectivity of some of these membranes, solution-diffusion pathways predominate. We also describe initial studies in which we formed hyperthin films from poly(ethylene glycol)-based polyelectrolytes using layer-by-layer deposition (LbL) methods. We have found remarkably high H2/CO2 and CO2/N2 permeation selectivities with these LB- and LbL-based hyperthin membranes. These

  18. NASA Accountability Report

    NASA Technical Reports Server (NTRS)

    1997-01-01

    NASA is piloting fiscal year (FY) 1997 Accountability Reports, which streamline and upgrade reporting to Congress and the public. The document presents statements by the NASA administrator, and the Chief Financial Officer, followed by an overview of NASA's organizational structure and the planning and budgeting process. The performance of NASA in four strategic enterprises is reviewed: (1) Space Science, (2) Mission to Planet Earth, (3) Human Exploration and Development of Space, and (4) Aeronautics and Space Transportation Technology. Those areas which support the strategic enterprises are also reviewed in a section called Crosscutting Processes. For each of the four enterprises, there is discussion about the long term goals, the short term objectives and the accomplishments during FY 1997. The Crosscutting Processes section reviews issues and accomplishments relating to human resources, procurement, information technology, physical resources, financial management, small and disadvantaged businesses, and policy and plans. Following the discussion about the individual areas is Management's Discussion and Analysis, about NASA's financial statements. This is followed by a report by an independent commercial auditor and the financial statements.

  19. Holding services to account

    PubMed Central

    Clegg, J

    2008-01-01

    Background Recently, the frequency of audit inspections of health services for people with intellectual disability (ID) in the UK has increased, from occasional inquiries to a systematic audit of all services. From 2008, a process of continuous audit ‘surveillance’ of specialist health services is to be introduced. Similar regimes of inspection are in place for social care services. Aim To explore the conceptual positions which inform audit, through detailed examination of the investigation into the learning disability service at Sutton and Merton. Findings Audit is distinct from evaluation because it neither provides opportunities for service staff to give an account of their work nor represents a search for knowledge. Audit investigates adherence to government policy. In ID, audits measure aspirations derived from normalisation, despite research showing that some of these aspirations have not been achieved by any service. As audit consumes significant public resource, it is questionable whether the dominant finding of the Healthcare Commission's investigation into Sutton and Merton, that the ID service was chronically under-funded, represents value for money. Discussion and conclusions While basic checks on minimum standards will always be necessary, service excellence requires not audit but research-driven evaluation. Audits inhibit rather than open-up debate about improving support to people with ID. They impose an ideology, squander resource, and demoralise carers and staff. Evaluations challenge the implicit management-versus-professional binary enacted by audit, and can inform new care systems which make effective use of all those engaged with people with ID. PMID:18498335

  20. Spills, drills, and accountability

    SciTech Connect

    1993-12-31

    NRDC seeks preventive approaches to oil pollution on U.S. coasts. The recent oil spills in Spain and Scotland have highlighted a fact too easy to forget in a society that uses petroleum every minute of every day: oil is profoundly toxic. One tiny drop on a bald eagle`s egg has been known to kill the embryo inside. Every activity involving oil-drilling for it, piping it, shipping it-poses risks that must be taken with utmost caution. Moreover, oil production is highly polluting. It emits substantial air pollution, such as nitrogen oxides that can form smog and acid rain. The wells bring up great quantities of toxic waste: solids, liquids and sludges often contaminated by oil, toxic metals, or even radioactivity. This article examines the following topics focusing on oil pollution control and prevention in coastal regions of the USA: alternate energy sources and accountability of pollutor; ban on offshore drilling as exemplified by the energy policy act; tanker free zones; accurate damage evaluations. Policy of the National Resource Defence Council is articulated.

  1. Your accounts. National Savings.

    PubMed

    Hepburn, P F

    1984-01-01

    National Savings must be regarded as a conservative investment option and different types of contract suit different types of taxpayer and investor. The three main attractions are as follows: National Savings Certificates including the index-linked issue and the returns on SAYE contracts are free of all forms of taxation and thus in most cases provide attractive potential for those who pay tax at the highest rate. In the majority of cases returns are guaranteed, often over long periods of time, and even when returns are variable they can generally be expected to be very competitive compared with all other forms of conservative saving, both long-term and short-term. Interest is paid or credited without deduction of tax at source, this being a particular attraction to those who pay no tax. Table 1 shows how differing marginal tax rates are extremely significant, although accessibility should also be taken into account and this is perhaps where National Savings carry some drawbacks, especially during the first 12 months.

  2. Accounting Issues: An Essay Series. Part II--Accounts Receivable

    ERIC Educational Resources Information Center

    Laux, Judith A.

    2007-01-01

    This is the second in a series of articles designed to help academics refocus the introductory accounting course on the theoretical underpinnings of accounting. Intended as a supplement for the principles course, this article connects the asset Accounts Receivable to the essential theoretical constructs, discusses the inherent tradeoffs and…

  3. Accounting: The Integration of Computers into the Accounting Class.

    ERIC Educational Resources Information Center

    Brown, Dorothy Lee

    1980-01-01

    Since computers are universally accepted in business today, the accounting classroom is the appropriate place to teach their use. A California high school accounting committee's recommendation led to the school's development of a computer processing program within the accounting department. The program's curriculum is described. (CT)

  4. 18 CFR 367.2320 - Account 232, Accounts payable.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... payable. This account must include all amounts payable by the service company within one year that are not... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 232, Accounts payable. 367.2320 Section 367.2320 Conservation of Power and Water Resources FEDERAL ENERGY...

  5. Solving Accounting Problems: Differences between Accounting Experts and Novices.

    ERIC Educational Resources Information Center

    Marshall, P. Douglas

    2002-01-01

    Performance of 90 accounting experts (faculty and practitioners) and 60 novices (senior accounting majors) was compared. Experts applied more accounting principles to solving problems. There were no differences in types of principles applied and no correlation between (1) principles applied and number of breadth comments or (2) importance placed…

  6. [Removal of CO2 from simulated flue gas of power plants by membrane-based gas absorption processes].

    PubMed

    Yang, Ming-Fen; Fang, Meng-Xiang; Zhang, Wei-Feng; Wang, Shu-Yuan; Xu, Zhi-Kang; Luo, Zhong-Yang; Cen, Ke-Fa

    2005-07-01

    Three typical absorbents such as aqueous of aminoacetic acid potassium (AAAP), monoethanolamine (MEA) and methyldiethanolamine(MDEA) are selected to investigate the performance of CO2 separation from flue gas via membrane contactors made of hydrophobic hollow fiber polypropylene porous membrane. Impacts of absorbents, concentrations and flow rates of feeding gas and absorbent solution, cyclic loading of CO2 on the removal rate and the mass transfer velocity of CO2 are discussed. The results demonstrate that the mass transfer velocity was 7.1 mol x (m2 x s)(-1) for 1 mol x L(-1) MEA with flow rate of 0.1 m x s(-1) and flue gas with that of 0.211 m x s(-1). For 1 mol L(-1) AAAP with flow rate of 0.05 m x s(-1) and flue gas of 0.211 m x s(-1), CO2 removal rate (eta) was 93.2 % and eta was 98% for 4 mol x L(-1) AAAP under the same conditions. AAAP being absorbent, eta was higher than 90% in a wider range of concentrations of CO2. It indicates that membrane-based absorption process is a widely-applied and promising way of CO2 removal from flue gas of power plants, which not only appropriates for CO2 removal of flue gas of widely-used PF and NGCC, but also for that of flue gas of IGCC can be utilized widely in future.

  7. Accountability report - fiscal year 1997

    SciTech Connect

    1998-04-01

    This document contains the US NRC`s accountability report for fiscal year 1997. Topics include uses of funds, financial condition, program performance, management accountability, and the audited financial statement.

  8. V5 AND V10 CONTACTOR TESTING WITH THE NEXT GENERATION (CSSX) SOLVENT FOR THE SAVANNAH RIVER SITE INTEGRATED SALT DISPOSITION PROCESS

    SciTech Connect

    Restivo, M.; Peters, T.; Pierce, R.; Fondeur, F.; Steeper, T.; Williams, M.; Giddings, B.; Hickman, B.; Fink, S.

    2012-01-17

    program to test the full size strip (V5) and extraction (V10) centrifugal contactors and the associated strip and extraction effluent coalescers to determine the hydraulic and mass transfer characteristics with the NGS. The test program evaluated the amount of organic carryover and the droplet size of the carryover phases using several analytical methods. Provisions were also made to enable an evaluation of coalescer performance. Stage efficiency and mass distribution ratios were determined using Cs mass transfer measurements. Using 20 millimolar (mM) extractant (instead of 50 mM), the nominal D(Cs) measured was 16.0-17.5. The data indicate that equilibrium is achieved rapidly and maintained throughout sampling. The data showed good stage efficiency for extraction (Tests 1A-1D), ranging from 98.2% for Test 1A to 90.5% for Test 1D. No statistically-significant differences were noted for operations at 12 gpm aqueous flow when compared with either 4 gpm or 8 gpm of aqueous flow. The stage efficiencies equal or exceed those previously measured using the baseline CSSX solvent system. The nominal target for scrub Cs distribution values are {approx}1.0-2.5. The first scrub test yielded an average scrub value of 1.21 and the second scrub test produced an average value of 0.78. Both values are considered acceptable. Stage efficiency was not calculated for the scrub tests. For stripping behavior, six tests were completed in a manner to represent the first strip stage. For three tests at the baseline flow ratios (O:A of 3.75:1) but at different total flow rates, the D(Cs) values were all similar at {approx}0.052. Similar behavior was observed for two tests performed at an O:A ratio of 7:1 instead of 3.75:1. The data for the baseline strip tests exhibited acceptable stage efficiency, ranging from 82.0% for low flow to 89-90% for medium and high flow. The difference in efficiency may be attributable to the low volume in the contactor housing at lower flow rates. The concentrations of

  9. Rapid Preparation of a Plasma Membrane Fraction: Western Blot Detection of Translocated Glucose Transporter 4 from Plasma Membrane of Muscle and Adipose Cells and Tissues.

    PubMed

    Yamamoto, Norio; Yamashita, Yoko; Yoshioka, Yasukiyo; Nishiumi, Shin; Ashida, Hitoshi

    2016-08-01

    Membrane proteins account for 70% to 80% of all pharmaceutical targets, indicating their clinical relevance and underscoring the importance of identifying differentially expressed membrane proteins that reflect distinct disease properties. The translocation of proteins from the bulk of the cytosol to the plasma membrane is a critical step in the transfer of information from membrane-embedded receptors or transporters to the cell interior. To understand how membrane proteins work, it is important to separate the membrane fraction of cells. This unit provides a protocol for rapidly obtaining plasma membrane fractions for western blot analysis. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.

  10. Model Accounting Program. Adopters Guide.

    ERIC Educational Resources Information Center

    Beaverton School District 48, OR.

    The accounting cluster demonstration project conducted at Aloha High School in the Beaverton, Oregon, school district developed a model curriculum for high school accounting. The curriculum is based on interviews with professionals in the accounting field and emphasizes the use of computers. It is suitable for use with special needs students as…

  11. 46 CFR Sec. 5 - Accounting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Accounting. Sec. 5 Section 5 Shipping MARITIME... Sec. 5 Accounting. The General Agent shall record the amounts of compensation paid from the NSA... Accounting Office, at which time the Maritime Administration will take custody of the records. ...

  12. Standardized Testing and School Accountability

    ERIC Educational Resources Information Center

    Wiliam, Dylan

    2010-01-01

    This article explores the use of standardized tests to hold schools accountable. The history of testing for accountability is reviewed, and it is shown that currently between-school differences account for less than 10% of the variance in student scores, in part because the progress of individuals is small compared to the spread of achievement…

  13. How to Professionalize Accounting Programs

    ERIC Educational Resources Information Center

    Allyn, Robert G.

    1977-01-01

    The author, a certified public accountant on the State Board for Public Accountancy of New York, Discusses education and training programs to "professionalize" accounting, particularly the need for innovative learning modules that integrate the traditional sequence of courses in baccalaureate programs. (MF)

  14. Model Accounting Program. Adopters Guide.

    ERIC Educational Resources Information Center

    Beaverton School District 48, OR.

    The accounting cluster demonstration project conducted at Aloha High School in the Beaverton, Oregon, school district developed a model curriculum for high school accounting. The curriculum is based on interviews with professionals in the accounting field and emphasizes the use of computers. It is suitable for use with special needs students as…

  15. Mastering the Vocabulary of Accounting.

    ERIC Educational Resources Information Center

    Tischler, Helene

    Developed for use by students in an introductory accounting course, these learning modules deal with mastering the vocabulary of accounting. Focus of the modules is on vocabulary appearing in the first six chapters of the text, "Accounting Principles" by Niswonger and Fess. Covered in the individual modules are the following topics:…

  16. An Accounting Writing Proficiency Survey

    ERIC Educational Resources Information Center

    Firch, Tim; Campbell, Annhenrie; Filling, Steven; Lindsay, David H.

    2011-01-01

    Although there has been much discussion about improving college student writing with college-level courses, little is known about how accounting programs, in particular, are addressing the writing proficiency challenge. This study surveys the 852 accounting programs in the United States to identify the frequency and types of accounting writing…

  17. Accounting Systems for School Districts.

    ERIC Educational Resources Information Center

    Atwood, E. Barrett, Jr.

    1983-01-01

    Advises careful analysis and improvement of existing school district accounting systems prior to investment in new ones. Emphasizes the importance of attracting and maintaining quality financial staffs, developing an accounting policies and procedures manual, and designing a good core accounting system before purchasing computer hardware and…

  18. 46 CFR Sec. 5 - Accounting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 8 2011-10-01 2011-10-01 false Accounting. Sec. 5 Section 5 Shipping MARITIME... Sec. 5 Accounting. The General Agent shall record the amounts of compensation paid from the NSA... Accounting Office, at which time the Maritime Administration will take custody of the records....

  19. 46 CFR Sec. 5 - Accounting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 8 2012-10-01 2012-10-01 false Accounting. Sec. 5 Section 5 Shipping MARITIME... Sec. 5 Accounting. The General Agent shall record the amounts of compensation paid from the NSA... Accounting Office, at which time the Maritime Administration will take custody of the records....

  20. 46 CFR Sec. 5 - Accounting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 8 2013-10-01 2013-10-01 false Accounting. Sec. 5 Section 5 Shipping MARITIME... Sec. 5 Accounting. The General Agent shall record the amounts of compensation paid from the NSA... Accounting Office, at which time the Maritime Administration will take custody of the records....

  1. 46 CFR Sec. 5 - Accounting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 8 2014-10-01 2014-10-01 false Accounting. Sec. 5 Section 5 Shipping MARITIME... Sec. 5 Accounting. The General Agent shall record the amounts of compensation paid from the NSA... Accounting Office, at which time the Maritime Administration will take custody of the records....

  2. Accounting Instruction Builds Economic Literacy.

    ERIC Educational Resources Information Center

    Albaugh, Thomas A.; Porreca, Anthony G.

    1985-01-01

    A study of 236 11th-grade accounting students was conducted to measure the economic literacy of students enrolled in high school business education. It was found that those students who had accounting instruction had mean scores that were higher than those students who did not have accounting instruction. (CT)

  3. Vocational Accounting and Computing Programs.

    ERIC Educational Resources Information Center

    Avani, Nathan T.

    1986-01-01

    Describes an "Accounting and Computing" program in Michigan that emphasizes computerized accounting procedures. This article describes the program curriculum and duty areas (such as handling accounts receivable), presents a list of sample tasks in each duty area, and specifies components of each task. Computer equipment necessary for this program…

  4. Mastering the Vocabulary of Accounting.

    ERIC Educational Resources Information Center

    Tischler, Helene

    Developed for use by students in an introductory accounting course, these learning modules deal with mastering the vocabulary of accounting. Focus of the modules is on vocabulary appearing in the first six chapters of the text, "Accounting Principles" by Niswonger and Fess. Covered in the individual modules are the following topics:…

  5. Poly/vinyl alcohol/ membranes for reverse osmosis

    NASA Technical Reports Server (NTRS)

    Katz, M. G.; Wydeven, T., Jr.

    1981-01-01

    A description is presented of the results of studies of the water and salt transport properties of PVA membranes, taking into account radiation crosslinked PVA membranes, diffusive salt permeability through PVA membranes, and heat treated PVA membranes. The experimental findings support an occurrence of independent water, and salt permeation processes. It is suggested that the salt permeation is governed by a solution-diffusion transport mechanism. The preparation of thin skinned, asymmetric PVA membranes is also discussed. The employed method has a certain similarity to the classical phase inversion method, which is widely applied in the casting of asymmetric reverse osmosis membranes. Instead of using a gelling bath composed of a nonsolvent for the membrane material and miscible with the solvent from which the membrane is cast, a 'complexing' bath is used, which is a solution of a complexing agent in water.

  6. Poly/vinyl alcohol/ membranes for reverse osmosis

    NASA Technical Reports Server (NTRS)

    Katz, M. G.; Wydeven, T., Jr.

    1981-01-01

    A description is presented of the results of studies of the water and salt transport properties of PVA membranes, taking into account radiation crosslinked PVA membranes, diffusive salt permeability through PVA membranes, and heat treated PVA membranes. The experimental findings support an occurrence of independent water, and salt permeation processes. It is suggested that the salt permeation is governed by a solution-diffusion transport mechanism. The preparation of thin skinned, asymmetric PVA membranes is also discussed. The employed method has a certain similarity to the classical phase inversion method, which is widely applied in the casting of asymmetric reverse osmosis membranes. Instead of using a gelling bath composed of a nonsolvent for the membrane material and miscible with the solvent from which the membrane is cast, a 'complexing' bath is used, which is a solution of a complexing agent in water.

  7. Experimenting with Liquid Membranes.

    ERIC Educational Resources Information Center

    Lamb, J. D.; And Others

    1980-01-01

    Outlined are two experiments using liquid membranes that illustrate carrier-facilitated transport, where chemical species are ushered across the membrane by selective "carrier" molecules residing in the membrane. The use of liquid membranes as models for studying and describing biological transport mechanisms is explored. (CS)

  8. Composite sensor membrane

    DOEpatents

    Majumdar, Arun; Satyanarayana, Srinath; Yue, Min

    2008-03-18

    A sensor may include a membrane to deflect in response to a change in surface stress, where a layer on the membrane is to couple one or more probe molecules with the membrane. The membrane may deflect when a target molecule reacts with one or more probe molecules.

  9. 40 CFR 97.520 - Establishment of compliance accounts, assurance accounts, and general accounts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Establishment of compliance accounts, assurance accounts, and general accounts. 97.520 Section 97.520 Protection of Environment ENVIRONMENTAL... persons who have an ownership interest with respect to TR NOX Ozone Season allowances held in the...

  10. 40 CFR 97.720 - Establishment of compliance accounts, assurance accounts, and general accounts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Establishment of compliance accounts, assurance accounts, and general accounts. 97.720 Section 97.720 Protection of Environment ENVIRONMENTAL... persons who have an ownership interest with respect to TR SO2 Group 2 allowances held in the...

  11. 40 CFR 97.420 - Establishment of compliance accounts, assurance accounts, and general accounts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Establishment of compliance accounts, assurance accounts, and general accounts. 97.420 Section 97.420 Protection of Environment ENVIRONMENTAL... persons who have an ownership interest with respect to TR NOX Annual allowances held in the...

  12. 40 CFR 97.420 - Establishment of compliance accounts, assurance accounts, and general accounts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Establishment of compliance accounts, assurance accounts, and general accounts. 97.420 Section 97.420 Protection of Environment ENVIRONMENTAL... persons who have an ownership interest with respect to TR NOX Annual allowances held in the...

  13. 40 CFR 97.620 - Establishment of compliance accounts, assurance accounts, and general accounts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Establishment of compliance accounts, assurance accounts, and general accounts. 97.620 Section 97.620 Protection of Environment ENVIRONMENTAL... persons who have an ownership interest with respect to TR SO2 Group 1 allowances held in the...

  14. 40 CFR 97.620 - Establishment of compliance accounts, assurance accounts, and general accounts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Establishment of compliance accounts, assurance accounts, and general accounts. 97.620 Section 97.620 Protection of Environment ENVIRONMENTAL... persons who have an ownership interest with respect to TR SO2 Group 1 allowances held in the...

  15. 40 CFR 97.720 - Establishment of compliance accounts, assurance accounts, and general accounts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Establishment of compliance accounts, assurance accounts, and general accounts. 97.720 Section 97.720 Protection of Environment ENVIRONMENTAL... persons who have an ownership interest with respect to TR SO2 Group 2 allowances held in the...

  16. 40 CFR 97.520 - Establishment of compliance accounts, assurance accounts, and general accounts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Establishment of compliance accounts, assurance accounts, and general accounts. 97.520 Section 97.520 Protection of Environment ENVIRONMENTAL... persons who have an ownership interest with respect to TR NOX Ozone Season allowances held in the...

  17. Membrane position control

    NASA Technical Reports Server (NTRS)

    Su, Ji (Inventor); Harrison, Joycelyn S. (Inventor)

    2004-01-01

    A membrane structure includes at least one electroactive bending actuator fixed to a supporting base. Each electroactive bending actuator is operatively connected to the membrane for controlling membrane position. Any displacement of each electroactive bending actuator effects displacement of the membrane. More specifically, the operative connection is provided by a guiding wheel assembly and a track, wherein displacement of the bending actuator effects translation of the wheel assembly along the track, thereby imparting movement to the membrane.

  18. Nanoporous Membrane Immunosensor

    DTIC Science & Technology

    2000-01-01

    Another aspect of the invention is a method for detecting an analyte in a test sample, having 5 the steps: (a) modifying a side of a semipermeable... side of the membrane with the membrane modifiers; (c) drawing the test sample through the membrane, osmotically or with the application of...immunoassay labels on the side of the membrane with the membrane modifiers, where these labels have label binding ligands where these label binding

  19. Polymer Diffusion in Lipid Membranes

    NASA Astrophysics Data System (ADS)

    Prasad, Ashok

    2005-03-01

    Motivated by experiments on fluorescently labeled DNA molecules on a supported lipid bilayer, we have examined theoretically diffusion of polymers in two dimensions. The key experimental finding we focus on is the scaling of the diffusion constant of the center of mass, D˜1/N. This implies that no effective hydrodynamic coupling exists between the diffusing DNA segments in the membrane. We construct our theoretical model using the phenomenological hydrodynamic model of supported membranes proposed by Evans and Sackmann. Our model is based on the pre-averaged Oseen tensor, and is similar to the model of Komura and Seki, but elaborated and extended to take explicit account of self-avoidance. We find that the 1/N scaling of D can be understood as a consequence of membrane hydrodynamics in the presence of a supporting surface. Further experimental consequences of the model, in particular the diffusion constant for DNA in free standing membranes, will also be discussed. This work was supported by the NSF through grants DMR-9984471 and DMR-0403997. JK is a Cottrell Scholar of Research Corporation.

  20. The Escherichia coli Peripheral Inner Membrane Proteome*

    PubMed Central

    Papanastasiou, Malvina; Orfanoudaki, Georgia; Koukaki, Marina; Kountourakis, Nikos; Sardis, Marios Frantzeskos; Aivaliotis, Michalis; Karamanou, Spyridoula; Economou, Anastassios

    2013-01-01

    Biological membranes are essential for cell viability. Their functional characteristics strongly depend on their protein content, which consists of transmembrane (integral) and peripherally associated membrane proteins. Both integral and peripheral inner membrane proteins mediate a plethora of biological processes. Whereas transmembrane proteins have characteristic hydrophobic stretches and can be predicted using bioinformatics approaches, peripheral inner membrane proteins are hydrophilic, exist in equilibria with soluble pools, and carry no discernible membrane targeting signals. We experimentally determined the cytoplasmic peripheral inner membrane proteome of the model organism Escherichia coli using a multidisciplinary approach. Initially, we extensively re-annotated the theoretical proteome regarding subcellular localization using literature searches, manual curation, and multi-combinatorial bioinformatics searches of the available databases. Next we used sequential biochemical fractionations coupled to direct identification of individual proteins and protein complexes using high resolution mass spectrometry. We determined that the proposed cytoplasmic peripheral inner membrane proteome occupies a previously unsuspected ∼19% of the basic E. coli BL21(DE3) proteome, and the detected peripheral inner membrane proteome occupies ∼25% of the estimated expressed proteome of this cell grown in LB medium to mid-log phase. This value might increase when fleeting interactions, not studied here, are taken into account. Several proteins previously regarded as exclusively cytoplasmic bind membranes avidly. Many of these proteins are organized in functional or/and structural oligomeric complexes that bind to the membrane with multiple interactions. Identified proteins cover the full spectrum of biological activities, and more than half of them are essential. Our data suggest that the cytoplasmic proteome displays remarkably dynamic and extensive communication with