NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Jackson, Karen E.; Lyle, Karen H.; Spellman, Regina L.
2006-01-01
A study was performed to examine the influence of varying mesh density on an LS-DYNA simulation of a rectangular-shaped foam projectile impacting the space shuttle leading edge Panel 6. The shuttle leading-edge panels are fabricated of reinforced carbon-carbon (RCC) material. During the study, nine cases were executed with all possible combinations of coarse, baseline, and fine meshes of the foam and panel. For each simulation, the same material properties and impact conditions were specified and only the mesh density was varied. In the baseline model, the shell elements representing the RCC panel are approximately 0.2-in. on edge, whereas the foam elements are about 0.5-in. on edge. The element nominal edge-length for the baseline panel was halved to create a fine panel (0.1-in. edge length) mesh and doubled to create a coarse panel (0.4-in. edge length) mesh. In addition, the element nominal edge-length of the baseline foam projectile was halved (0.25-in. edge length) to create a fine foam mesh and doubled (1.0-in. edge length) to create a coarse foam mesh. The initial impact velocity of the foam was 775 ft/s. The simulations were executed in LS-DYNA for 6 ms of simulation time. Contour plots of resultant panel displacement and effective stress in the foam were compared at four discrete time intervals. Also, time-history responses of internal and kinetic energy of the panel, kinetic and hourglass energy of the foam, and resultant contact force were plotted to determine the influence of mesh density.
NASA Technical Reports Server (NTRS)
Jackson, Karen E.; Fasanella, Edwin L.; Lyle, Karen H.; Spellman, Regina L.
2004-01-01
A study was performed to examine the influence of varying mesh density on an LS-DYNA simulation of a rectangular-shaped foam projectile impacting the space shuttle leading edge Panel 6. The shuttle leading-edge panels are fabricated of reinforced carbon-carbon (RCC) material. During the study, nine cases were executed with all possible combinations of coarse, baseline, and fine meshes of the foam and panel. For each simulation, the same material properties and impact conditions were specified and only the mesh density was varied. In the baseline model, the shell elements representing the RCC panel are approximately 0.2-in. on edge, whereas the foam elements are about 0.5-in. on edge. The element nominal edge-length for the baseline panel was halved to create a fine panel (0.1-in. edge length) mesh and doubled to create a coarse panel (0.4-in. edge length) mesh. In addition, the element nominal edge-length of the baseline foam projectile was halved (0.25-in. edge length) to create a fine foam mesh and doubled (1.0- in. edge length) to create a coarse foam mesh. The initial impact velocity of the foam was 775 ft/s. The simulations were executed in LS-DYNA version 960 for 6 ms of simulation time. Contour plots of resultant panel displacement and effective stress in the foam were compared at five discrete time intervals. Also, time-history responses of internal and kinetic energy of the panel, kinetic and hourglass energy of the foam, and resultant contact force were plotted to determine the influence of mesh density. As a final comparison, the model with a fine panel and fine foam mesh was executed with slightly different material properties for the RCC. For this model, the average degraded properties of the RCC were replaced with the maximum degraded properties. Similar comparisons of panel and foam responses were made for the average and maximum degraded models.
Predicting mesh density for adaptive modelling of the global atmosphere.
Weller, Hilary
2009-11-28
The shallow water equations are solved using a mesh of polygons on the sphere, which adapts infrequently to the predicted future solution. Infrequent mesh adaptation reduces the cost of adaptation and load-balancing and will thus allow for more accurate mapping on adaptation. We simulate the growth of a barotropically unstable jet adapting the mesh every 12 h. Using an adaptation criterion based largely on the gradient of the vorticity leads to a mesh with around 20 per cent of the cells of a uniform mesh that gives equivalent results. This is a similar proportion to previous studies of the same test case with mesh adaptation every 1-20 min. The prediction of the mesh density involves solving the shallow water equations on a coarse mesh in advance of the locally refined mesh in order to estimate where features requiring higher resolution will grow, decay or move to. The adaptation criterion consists of two parts: that resolved on the coarse mesh, and that which is not resolved and so is passively advected on the coarse mesh. This combination leads to a balance between resolving features controlled by the large-scale dynamics and maintaining fine-scale features.
Mesh control information of windmill designed by Solidwork program
NASA Astrophysics Data System (ADS)
Mulyana, T.; Sebayang, D.; Rafsanjani, A. M. D.; Adani, J. H. D.; Muhyiddin, Y. S.
2017-12-01
This paper presents the mesh control information imposed on the windmill already designed. The accuracy of Simulation results is influenced by the quality of the created mesh. However, compared to the quality of the mesh is made, the simulation time running will be done software also increases. The smaller the size of the elements created when making the mesh, the better the mesh quality will be generated. When adjusting the mesh size, there is a slider that acts as the density regulator of the element. SolidWorks Simulation also has Mesh Control facility. Features that can adjust mesh density only in the desired part. The best results of mesh control obtained for both static and thermal simulation have ratio 1.5.
Zhang, Xiaoyan; Kim, Daeseung; Shen, Shunyao; Yuan, Peng; Liu, Siting; Tang, Zhen; Zhang, Guangming; Zhou, Xiaobo; Gateno, Jaime
2017-01-01
Accurate surgical planning and prediction of craniomaxillofacial surgery outcome requires simulation of soft tissue changes following osteotomy. This can only be achieved by using an anatomically detailed facial soft tissue model. The current state-of-the-art of model generation is not appropriate to clinical applications due to the time-intensive nature of manual segmentation and volumetric mesh generation. The conventional patient-specific finite element (FE) mesh generation methods are to deform a template FE mesh to match the shape of a patient based on registration. However, these methods commonly produce element distortion. Additionally, the mesh density for patients depends on that of the template model. It could not be adjusted to conduct mesh density sensitivity analysis. In this study, we propose a new framework of patient-specific facial soft tissue FE mesh generation. The goal of the developed method is to efficiently generate a high-quality patient-specific hexahedral FE mesh with adjustable mesh density while preserving the accuracy in anatomical structure correspondence. Our FE mesh is generated by eFace template deformation followed by volumetric parametrization. First, the patient-specific anatomically detailed facial soft tissue model (including skin, mucosa, and muscles) is generated by deforming an eFace template model. The adaptation of the eFace template model is achieved by using a hybrid landmark-based morphing and dense surface fitting approach followed by a thin-plate spline interpolation. Then, high-quality hexahedral mesh is constructed by using volumetric parameterization. The user can control the resolution of hexahedron mesh to best reflect clinicians’ need. Our approach was validated using 30 patient models and 4 visible human datasets. The generated patient-specific FE mesh showed high surface matching accuracy, element quality, and internal structure matching accuracy. They can be directly and effectively used for clinical simulation of facial soft tissue change. PMID:29027022
Zhang, Xiaoyan; Kim, Daeseung; Shen, Shunyao; Yuan, Peng; Liu, Siting; Tang, Zhen; Zhang, Guangming; Zhou, Xiaobo; Gateno, Jaime; Liebschner, Michael A K; Xia, James J
2018-04-01
Accurate surgical planning and prediction of craniomaxillofacial surgery outcome requires simulation of soft tissue changes following osteotomy. This can only be achieved by using an anatomically detailed facial soft tissue model. The current state-of-the-art of model generation is not appropriate to clinical applications due to the time-intensive nature of manual segmentation and volumetric mesh generation. The conventional patient-specific finite element (FE) mesh generation methods are to deform a template FE mesh to match the shape of a patient based on registration. However, these methods commonly produce element distortion. Additionally, the mesh density for patients depends on that of the template model. It could not be adjusted to conduct mesh density sensitivity analysis. In this study, we propose a new framework of patient-specific facial soft tissue FE mesh generation. The goal of the developed method is to efficiently generate a high-quality patient-specific hexahedral FE mesh with adjustable mesh density while preserving the accuracy in anatomical structure correspondence. Our FE mesh is generated by eFace template deformation followed by volumetric parametrization. First, the patient-specific anatomically detailed facial soft tissue model (including skin, mucosa, and muscles) is generated by deforming an eFace template model. The adaptation of the eFace template model is achieved by using a hybrid landmark-based morphing and dense surface fitting approach followed by a thin-plate spline interpolation. Then, high-quality hexahedral mesh is constructed by using volumetric parameterization. The user can control the resolution of hexahedron mesh to best reflect clinicians' need. Our approach was validated using 30 patient models and 4 visible human datasets. The generated patient-specific FE mesh showed high surface matching accuracy, element quality, and internal structure matching accuracy. They can be directly and effectively used for clinical simulation of facial soft tissue change.
Higuchi, Masatoshi; Moroi, Akinori; Yoshizawa, Kunio; Kosaka, Akihiko; Ikawa, Hiroumi; Iguchi, Ran; Saida, Yuriko; Hotta, Asami; Tsutsui, Takamitsu; Ueki, Koichiro
2016-09-01
The purpose of this study was to compare bone regenerative capability following use of polytetrafluoroethylene (ePTFE) membrane against that when various densities of pore titanium meshes are used with and without low intensity pulsed ultrasound (LIPUS). Adult male white rabbits were divided into 8 groups. In 4 groups, after incising along the nasal bone, four 3 × 8 mm bone defects were made in both sides and covered by an ePTFE membrane (group E: n = 15), a high density pore titanium mesh (group H: n = 15), a low density pore titanium mesh (group L: n = 15), and no mesh (control) (group C: n = 15). Furthermore, LIPUS was irradiated after surgery in 4 groups (groups EL, HL, LL and CL, in each n = 15). The rabbits were sacrificed at 1, 2 and 8 weeks postoperative, and formalin-fixed specimens were embedded in acrylic resin. The specimens were stained with hematoxylin and eosin. For immunohistochemical analysis, the specimens were treated with bone morphogenetic protein (BMP)-2 antibody. Group H had significantly higher values than groups L, E, and C regarding bone area ratio and labeling index of BMP-2 positive cells (P < 0.05). Furthermore, Group HL also had significantly higher values than the other groups regarding bone area ratio and labeling index of BMP-2 positive cells at 1, 2 and 8 weeks postoperative (P < 0.05). The results suggested that high density pore titanium mesh could induce new bone regeneration more than low density pore titanium mesh and ePTFE membrane. New bone formation may increase following LIPUS application. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Carro, Jose Luis Porrero; Riu, Sol Villar; Lojo, Beatriz Ramos; Latorre, Lucia; Garcia, Maria Teresa Alonso; Pardo, Benito Alcaide; Naranjo, Oscar Bonachia; Herrero, Alberto Marcos; Cabezudo, Carlos Sanchez; Herreras, Esther Quiros
2017-12-01
We present a randomized clinical trial to compare postoperative pain, complications, feeling of a foreign body, and recurrence between heavyweight and lightweight meshes in patients with bilateral groin hernia. Sixty-seven patients with bilateral hernia were included in our study. In each patient, the side of the lightweight mesh was decided by random numbers table. Pain score was measured by visual analogue scale, on 1st, 3rd, 5th, and 7th postoperative day, and one year after the surgery. There were no statistically significative differences between both meshes in postoperative complications. About differences of pain average, there were statistically significant differences only on the 1st postoperative day (P <0.01) and the 7th postoperative day (P <0.05). In the review after a year, there were no statistically significative differences in any parameter. In our study, we did not find statistically significative differences between lightweight and heavyweight meshes in postoperative pain, complications, feeling of a foreign body, and recurrence, except pain on 1st and 7th postoperative day.
Electrochemical reduction of UO2 in LiCl-Li2O molten salt using porous and nonporous anode shrouds
NASA Astrophysics Data System (ADS)
Choi, Eun-Young; Won, Chan Yeon; Cha, Ju-Sun; Park, Wooshin; Im, Hun Suk; Hong, Sun-Seok; Hur, Jin-Mok
2014-01-01
Electrochemical reductions of uranium oxide in a molten LiCl-Li2O electrolyte were carried out using porous and nonporous anode shrouds. The study focused on the effect of the type of anode shroud on the current density by running experiments with six anode shrouds. Dense ceramics, MgO, and MgO (3 wt%) stabilized ZrO2 (ZrO2-MgO) were used as nonporous shrouds. STS 20, 100, and 300 meshes and ZrO2-MgO coated STS 40 mesh were used as porous shrouds. The current densities (0.34-0.40 A cm-2) of the electrolysis runs using the nonporous anode shrouds were much lower than those (0.76-0.79 A cm-2) of the runs using the porous shrouds. The ZrO2-MgO shroud (600-700 MPa at 25 °C) showed better bending strength than that of MgO (170 MPa at 25 °C). The high current densities achieved in the electrolysis runs using the porous anode shrouds were attributed to the transport of O2- ions through the pores in meshes of the shroud wall. ZrO2-MgO coating on STS mesh was chemically unstable in a molten LiCl-Li2O electrolyte containing Li metal. The electrochemical reduction runs using STS 20, 100, and 300 meshes showed similar current densities in spite of their different opening sizes. The STS mesh shrouds which were immersed in a LiCl-Li2O electrolyte were stable without any damage or corrosion.
NASA Astrophysics Data System (ADS)
He, Jianmei
2017-11-01
Present metal artificial bones for bone grafts have the problems like too heavy and excessive elastic modulus compared with natural bones. In this study, three-dimensionally (3D) free-formable titanium mesh plates for bone graft applications was introduced to improve these problems. Fundamental mesh shapes and patterns were designed under different base shapes and design parameters through three dimensional CAD tools from higher flexibility and strength points of view. Based on the designed mesh shape and patterns, sample specimens of titanium mesh plates with different base shapes and design variables were manufactured through laser processing. Tensile properties of the sample titanium mesh plates like volume density, tensile elastic modulus were experimentally and analytically evaluated. Experimental results showed that such titanium mesh plates had much higher flexibility and their mechanical properties could be controlled to close to the natural bones. More details on the mechanical properties of titanium mesh plates including compression, bending, torsion and durability will be carried out in future study.
Li, Zuoping; Kindig, Matthew W; Subit, Damien; Kent, Richard W
2010-11-01
The purpose of this paper was to investigate the sensitivity of the structural responses and bone fractures of the ribs to mesh density, cortical thickness, and material properties so as to provide guidelines for the development of finite element (FE) thorax models used in impact biomechanics. Subject-specific FE models of the second, fourth, sixth and tenth ribs were developed to reproduce dynamic failure experiments. Sensitivity studies were then conducted to quantify the effects of variations in mesh density, cortical thickness, and material parameters on the model-predicted reaction force-displacement relationship, cortical strains, and bone fracture locations for all four ribs. Overall, it was demonstrated that rib FE models consisting of 2000-3000 trabecular hexahedral elements (weighted element length 2-3mm) and associated quadrilateral cortical shell elements with variable thickness more closely predicted the rib structural responses and bone fracture force-failure displacement relationships observed in the experiments (except the fracture locations), compared to models with constant cortical thickness. Further increases in mesh density increased computational cost but did not markedly improve model predictions. A ±30% change in the major material parameters of cortical bone lead to a -16.7 to 33.3% change in fracture displacement and -22.5 to +19.1% change in the fracture force. The results in this study suggest that human rib structural responses can be modeled in an accurate and computationally efficient way using (a) a coarse mesh of 2000-3000 solid elements, (b) cortical shells elements with variable thickness distribution and (c) a rate-dependent elastic-plastic material model. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Molecular surface mesh generation by filtering electron density map.
Giard, Joachim; Macq, Benoît
2010-01-01
Bioinformatics applied to macromolecules are now widely spread and in continuous expansion. In this context, representing external molecular surface such as the Van der Waals Surface or the Solvent Excluded Surface can be useful for several applications. We propose a fast and parameterizable algorithm giving good visual quality meshes representing molecular surfaces. It is obtained by isosurfacing a filtered electron density map. The density map is the result of the maximum of Gaussian functions placed around atom centers. This map is filtered by an ideal low-pass filter applied on the Fourier Transform of the density map. Applying the marching cubes algorithm on the inverse transform provides a mesh representation of the molecular surface.
Hydrogen atom kinetics in capacitively coupled plasmas
NASA Astrophysics Data System (ADS)
Nunomura, Shota; Katayama, Hirotaka; Yoshida, Isao
2017-05-01
Hydrogen (H) atom kinetics has been investigated in capacitively coupled very high frequency (VHF) discharges at powers of 16-780 mW cm-2 and H2 gas pressures of 0.1-2 Torr. The H atom density has been measured using vacuum ultra violet absorption spectroscopy (VUVAS) with a micro-discharge hollow cathode lamp as a VUV light source. The measurements have been performed in two different electrode configurations of discharges: conventional parallel-plate diode and triode with an intermediate mesh electrode. We find that in the triode configuration, the H atom density is strongly reduced across the mesh electrode. The H atom density varies from ˜1012 cm-3 to ˜1010 cm-3 by crossing the mesh with 0.2 mm in thickness and 36% in aperture ratio. The fluid model simulations for VHF discharge plasmas have been performed to study the H atom generation, diffusion and recombination kinetics. The simulations suggest that H atoms are generated in the bulk plasma, by the electron impact dissociation (e + H2 \\to e + 2H) and the ion-molecule reaction (H2 + + H2 \\to {{{H}}}3+ + H). The diffusion of H atoms is strongly limited by a mesh electrode, and thus the mesh geometry influences the spatial distribution of the H atoms. The loss of H atoms is dominated by the surface recombination.
Autoclaved Sand-Lime Products with a Polypropylene Mesh
NASA Astrophysics Data System (ADS)
Kostrzewa, Paulina; Stępień, Anna
2017-10-01
The paper presents the results of the research on modifications of silicate bricks with a polypropylene mesh and their influence on physical, mechanical and microstructural properties of such bricks. The main goal of the paper was to determine effects of the polypropylene mesh on sand-lime product parameters. The analysis has focused on compressive strength, water absorption, bulk density and structural features of the material. The obtained product is characterized by improved basic performance characteristics compared to traditional silicate products. Using the polypropylene mesh increased compressive strength by 25% while decreasing the product density. The modified products retain their form and do not disintegrate after losing their bearing capacity.
NASA Astrophysics Data System (ADS)
Sekiguchi, Koki; He, Jianmei
2017-11-01
GUM Metal has characteristics of lower elasticity rigidity, large elastic deformation, higher strength and biocompatibility etc. When it is used for implant applications, there is still problem like overloading on the natural-bone because of its high rigidity compared with the human bones. Therefore, the purpose of this study is to create more flexible meshed plates for implant applications from the viewpoints of elastic rigidity and volume density. Basic mesh shapes are designed, devised and applied for meshed GUM Metal plates using three dimensional (3D) CAD tools. Experimental evaluation on tensile fatigue characteristics of meshed GUM Metal plate specimens are carried out. Analytical approaches on stress evaluation are also executed through finite element method to obtain the S-N curve for fatigue characteristic evaluation.
Transport of phase space densities through tetrahedral meshes using discrete flow mapping
NASA Astrophysics Data System (ADS)
Bajars, Janis; Chappell, David J.; Søndergaard, Niels; Tanner, Gregor
2017-01-01
Discrete flow mapping was recently introduced as an efficient ray based method determining wave energy distributions in complex built up structures. Wave energy densities are transported along ray trajectories through polygonal mesh elements using a finite dimensional approximation of a ray transfer operator. In this way the method can be viewed as a smoothed ray tracing method defined over meshed surfaces. Many applications require the resolution of wave energy distributions in three-dimensional domains, such as in room acoustics, underwater acoustics and for electromagnetic cavity problems. In this work we extend discrete flow mapping to three-dimensional domains by propagating wave energy densities through tetrahedral meshes. The geometric simplicity of the tetrahedral mesh elements is utilised to efficiently compute the ray transfer operator using a mixture of analytic and spectrally accurate numerical integration. The important issue of how to choose a suitable basis approximation in phase space whilst maintaining a reasonable computational cost is addressed via low order local approximations on tetrahedral faces in the position coordinate and high order orthogonal polynomial expansions in momentum space.
A moving mesh finite difference method for equilibrium radiation diffusion equations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xiaobo, E-mail: xwindyb@126.com; Huang, Weizhang, E-mail: whuang@ku.edu; Qiu, Jianxian, E-mail: jxqiu@xmu.edu.cn
2015-10-01
An efficient moving mesh finite difference method is developed for the numerical solution of equilibrium radiation diffusion equations in two dimensions. The method is based on the moving mesh partial differential equation approach and moves the mesh continuously in time using a system of meshing partial differential equations. The mesh adaptation is controlled through a Hessian-based monitor function and the so-called equidistribution and alignment principles. Several challenging issues in the numerical solution are addressed. Particularly, the radiation diffusion coefficient depends on the energy density highly nonlinearly. This nonlinearity is treated using a predictor–corrector and lagged diffusion strategy. Moreover, the nonnegativitymore » of the energy density is maintained using a cutoff method which has been known in literature to retain the accuracy and convergence order of finite difference approximation for parabolic equations. Numerical examples with multi-material, multiple spot concentration situations are presented. Numerical results show that the method works well for radiation diffusion equations and can produce numerical solutions of good accuracy. It is also shown that a two-level mesh movement strategy can significantly improve the efficiency of the computation.« less
Mellano, Erin M; Nakamura, Leah Y; Choi, Judy M; Kang, Diana C; Grisales, Tamara; Raz, Shlomo; Rodriguez, Larissa V
2016-01-01
Vaginal mesh complications necessitating excision are increasingly prevalent. We aim to study whether subclinical chronically infected mesh contributes to the development of delayed-onset mesh complications or recurrent urinary tract infections (UTIs). Women undergoing mesh removal from August 2013 through May 2014 were identified by surgical code for vaginal mesh removal. Only women undergoing removal of anti-incontinence mesh were included. Exclusion criteria included any women undergoing simultaneous prolapse mesh removal. We abstracted preoperative and postoperative information from the medical record and compared mesh culture results from patients with and without mesh extrusion, de novo recurrent UTIs, and delayed-onset pain. One hundred seven women with only anti-incontinence mesh removed were included in the analysis. Onset of complications after mesh placement was within the first 6 months in 70 (65%) of 107 and delayed (≥6 months) in 37 (35%) of 107. A positive culture from the explanted mesh was obtained from 82 (77%) of 107 patients, and 40 (37%) of 107 were positive with potential pathogens. There were no significant differences in culture results when comparing patients with delayed-onset versus immediate pain, extrusion with no extrusion, and de novo recurrent UTIs with no infections. In this large cohort of patients with mesh removed for a diverse array of complications, cultures of the explanted vaginal mesh demonstrate frequent low-density bacterial colonization. We found no differences in culture results from women with delayed-onset pain versus acute pain, vaginal mesh extrusions versus no extrusions, or recurrent UTIs using standard culture methods. Chronic prosthetic infections in other areas of medicine are associated with bacterial biofilms, which are resistant to typical culture techniques. Further studies using culture-independent methods are needed to investigate the potential role of chronic bacterial infections in delayed vaginal mesh complications.
A preliminary study of the Caprella scaura amphipod culture for potential use in aquaculture
NASA Astrophysics Data System (ADS)
Baeza-Rojano, Elena; Calero-Cano, Sandra; Hachero-Cruzado, Ismael; Guerra-García, José Manuel
2013-10-01
The caprellid amphipod Caprella scaura Templeton, 1836 was investigated as a mass culture organism, for potential use as natural prey in aquaculture. C. scaura showed good population growth during 3 months of culturing with nauplii of Artemia sp. and microalgae as food source. A final mean population size of 12,510.67 individuals/tank and a maximum density of 10,460 individuals m- 2 were obtained; a 50-fold increase of the initial population was observed. Juveniles were the most abundant stage in the culture (86.0% of total), followed by mature females (5.4%) and immature males (3.1%). Three kinds of plastic mesh with different complexity levels were used as artificial substrates for amphipods to attach to and shelter. There were no significant differences in the total number of individuals present on each kind of mesh, although female and male adults were more abundant in folded meshes with larger pore diameter. This research demonstrated that the caprellid amphipod C. scaura may be readily cultured at high densities with a variety of mesh morphologies allowing more efficient use of tank volume and improved handling.
It's like night and day: Diel net-effects on Cercopagidae densities in the Laurentian Great Lakes
Armenio, Patricia M.; Bunnell, David B.; Adams, Jean V.; Watson, Nicole M.; Woelmer, Whitney
2017-01-01
In the Laurentian Great Lakes, zooplankters are often sampled using standard ≤153 μm mesh nets without regard to the time of day they are collected. We sampled Cercopagidae during 2013–2014 in northern Lake Huron during day, dusk, and night using two different nets (a 0.5 m wide 153 μm mesh “standard” net and a 0.75 m wide 285 μm mesh “Bythotrephes” net) to determine if there were any differences in their sampled densities. Bythotrephes densities with the standard net were approximately 2.07-fold greater when captured at night than during the day. No time of day bias occurred with the Bythotrephes net. Nighttime Bythotrephes densities did not differ between the two net types. Cercopagis densities did not vary with net type or the time of day in this study, but future work should revisit this result given our low sample size and the low occurrence of Cercopagis in Lake Huron. To reduce bias and calculate accurate density estimates, Cercopagidae should be sampled at night if using a standard net or any time of day with the Bythotrephes net. Given the large impact of invasive predatory cladocerans Bythotrephes longimanus and Cercopagis pengoi on food webs since their invasion in the Laurentian Great Lakes in the 1980s, proper estimation of their densities is essential.
NASA Astrophysics Data System (ADS)
Yuan, H. Z.; Wang, Y.; Shu, C.
2017-12-01
This paper presents an adaptive mesh refinement-multiphase lattice Boltzmann flux solver (AMR-MLBFS) for effective simulation of complex binary fluid flows at large density ratios. In this method, an AMR algorithm is proposed by introducing a simple indicator on the root block for grid refinement and two possible statuses for each block. Unlike available block-structured AMR methods, which refine their mesh by spawning or removing four child blocks simultaneously, the present method is able to refine its mesh locally by spawning or removing one to four child blocks independently when the refinement indicator is triggered. As a result, the AMR mesh used in this work can be more focused on the flow region near the phase interface and its size is further reduced. In each block of mesh, the recently proposed MLBFS is applied for the solution of the flow field and the level-set method is used for capturing the fluid interface. As compared with existing AMR-lattice Boltzmann models, the present method avoids both spatial and temporal interpolations of density distribution functions so that converged solutions on different AMR meshes and uniform grids can be obtained. The proposed method has been successfully validated by simulating a static bubble immersed in another fluid, a falling droplet, instabilities of two-layered fluids, a bubble rising in a box, and a droplet splashing on a thin film with large density ratios and high Reynolds numbers. Good agreement with the theoretical solution, the uniform-grid result, and/or the published data has been achieved. Numerical results also show its effectiveness in saving computational time and virtual memory as compared with computations on uniform meshes.
Airplane Mesh Development with Grid Density Studies
NASA Technical Reports Server (NTRS)
Cliff, Susan E.; Baker, Timothy J.; Thomas, Scott D.; Lawrence, Scott L.; Rimlinger, Mark J.
1999-01-01
Automatic Grid Generation Wish List Geometry handling, including CAD clean up and mesh generation, remains a major bottleneck in the application of CFD methods. There is a pressing need for greater automation in several aspects of the geometry preparation in order to reduce set up time and eliminate user intervention as much as possible. Starting from the CAD representation of a configuration, there may be holes or overlapping surfaces which require an intensive effort to establish cleanly abutting surface patches, and collections of many patches may need to be combined for more efficient use of the geometrical representation. Obtaining an accurate and suitable body conforming grid with an adequate distribution of points throughout the flow-field, for the flow conditions of interest, is often the most time consuming task for complex CFD applications. There is a need for a clean unambiguous definition of the CAD geometry. Ideally this would be carried out automatically by smart CAD clean up software. One could also define a standard piece-wise smooth surface representation suitable for use by computational methods and then create software to translate between the various CAD descriptions and the standard representation. Surface meshing remains a time consuming, user intensive procedure. There is a need for automated surface meshing, requiring only minimal user intervention to define the overall density of mesh points. The surface mesher should produce well shaped elements (triangles or quadrilaterals) whose size is determined initially according to the surface curvature with a minimum size for flat pieces, and later refined by the user in other regions if necessary. Present techniques for volume meshing all require some degree of user intervention. There is a need for fully automated and reliable volume mesh generation. In addition, it should be possible to create both surface and volume meshes that meet guaranteed measures of mesh quality (e.g. minimum and maximum angle, stretching ratios, etc.).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swift, D.W.
The author develops a code to simulate the dynamics in the magnetosphere system. The calculation involves a single level, structured, curvilinear 2D mesh. The mesh density is varied to support regions which demand higher resolution.
Zhao, Yan-feng; Lu, Ping; Zhou, Xiao-nan; Qu, Chang-feng
2010-03-01
To study the surgical management of enophthalmos after severe malar maxillary complex fracture. The X-ray and CT examination were performed before operation to diagnose the orbital fracture and intraorbital tissue displacement. The fractured orbital rim was repositioned intraoperatively, followed by implantation of shaped titanium mesh to rebuild the orbital floor. The Medpor was inserted above the titanium mesh to correct the enophthalmos. From Sept. 2007 to Jan. 2009, 6 cases of enophthalmos after severe malar-maxillary complex fracture were treated. The enophthalmos was corrected or improved obviously in all the patients. The enophthalmos after severe malar-maxillary complex fracture can be corrected or obviously improved. Shaped titanium mesh can be used to rebuild the orbital floor with the Medpor to reconstruct the intraorbital tissue volume.
Comparison of Hall Thruster Plume Expansion Model with Experimental Data (Preprint)
2006-07-01
Cartesian mesh. AQUILA, the focus of this study, is a hybrid PIC model that tracks particles along an unstructured tetrahedral mesh. COLISEUM is capable...measurements of the ion current density profile, ion energy distributions, and ion species fraction distributions using a nude Faraday probe...Spacecraft and Rockets, Vol.37 No.1. 6 Oh, D. and Hastings, D., “Three Dimensional PIC -DSMC Simulations of Hall Thruster Plumes and Analysis for
Lopes, Laís Fernanda de Palma; Agostini, Vanessa Ochi; Muxagata, Erik
2018-04-15
Many organizations have suggested the use of the Calanoid copepod Acartia tonsa in protocols for acute toxicity tests. Nevertheless, these protocols present some problems, such as using 60-180µm meshes to separate specific stages of A. tonsa or carrying out the tests using small volumes that reflect high densities of A. tonsa that do not occur in nature, which could lead to distorted results. In addition, ecotoxicological studies may use statistical approaches that are inadequate for the type of data being analysed. For these reasons, some methodological approaches for bioassays using A. tonsa need to be clarified and revised. In this study, we present information about (i) the retention of copepodite stages of A. tonsa on 180, 330 and 500µm net meshes; (ii) tested storage volumes of 1 organism per 5, 10 or 20mL in each test container (TC); and (iii) considerations about the statistics employed. The results demonstrated that a net mesh of 180µm is capable of retaining all copepodite stages (CI to CVI), contrasting with the recommendation of using a 180µm mesh to separate out adults only. Coarser meshes (330 and 500µm) can also retain different proportions of all copepodite stages, but cannot separate out one developmental stage only. Twenty-five millilitres of medium in an open TC, commonly employed in bioassays simulating densities of 1 organism 5mL -1 , completely evaporated, and the results showed that the TCs need to be covered (e.g., PVC film) and filled with a minimum of 100mL of culture medium (simulating densities of 1 organism 20mL -1 ) to avoid evaporation and increases in salinity. The current use of ANOVA in ecotoxicological studies with proportions of surviving organisms should also be reconsidered since the data are discrete and have a binomial distribution; general linear models (GLMs) are considered more adequate. The information presented here suggests some adjustments that hopefully will enable the improvement of the procedures and methods employed in studies of acute toxicity using the copepod A. tonsa. Copyright © 2017 Elsevier Inc. All rights reserved.
Effect of catalysts on dc corona discharge poisoning
NASA Astrophysics Data System (ADS)
Pekárek, S.
2011-02-01
The processes of ozone generation in non-thermal plasma produced by an electrical discharge in air at atmospheric pressure are burdened by the presence of nitrogen oxides, which on the one hand contribute to ozone generation and on the other hand are responsible for unpleasant discharge poisoning. The term discharge poisoning refers to the situation when the discharge ozone formation completely breaks down. Discharge poisoning can be affected by placing a catalyst in the discharge chamber. For the dc hollow needle to mesh corona discharge enhanced by the flow of air through the needle electrode we studied the effect of titanium dioxide TiO2, ZSM-5 zeolite or Cu++ZSM-5 zeolite on discharge poisoning by monitoring the ozone, nitrogen monoxide and nitrogen dioxide discharge production. We found that placing globules of any of these catalysts on the mesh decreases the energy density of the onset of discharge poisoning, and this energy density is smallest for a discharge with globules of a TiO2 on the mesh.
Campbell, J Q; Coombs, D J; Rao, M; Rullkoetter, P J; Petrella, A J
2016-09-06
The purpose of this study was to seek broad verification and validation of human lumbar spine finite element models created using a previously published automated algorithm. The automated algorithm takes segmented CT scans of lumbar vertebrae, automatically identifies important landmarks and contact surfaces, and creates a finite element model. Mesh convergence was evaluated by examining changes in key output variables in response to mesh density. Semi-direct validation was performed by comparing experimental results for a single specimen to the automated finite element model results for that specimen with calibrated material properties from a prior study. Indirect validation was based on a comparison of results from automated finite element models of 18 individual specimens, all using one set of generalized material properties, to a range of data from the literature. A total of 216 simulations were run and compared to 186 experimental data ranges in all six primary bending modes up to 7.8Nm with follower loads up to 1000N. Mesh convergence results showed less than a 5% difference in key variables when the original mesh density was doubled. The semi-direct validation results showed that the automated method produced results comparable to manual finite element modeling methods. The indirect validation results showed a wide range of outcomes due to variations in the geometry alone. The studies showed that the automated models can be used to reliably evaluate lumbar spine biomechanics, specifically within our intended context of use: in pure bending modes, under relatively low non-injurious simulated in vivo loads, to predict torque rotation response, disc pressures, and facet forces. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Pineda, Evan J.; Bednarcyk, Brett A.; Arnold, Steven M.; Waas, Anthony M.
2013-01-01
A mesh objective crack band model was implemented within the generalized method of cells micromechanics theory. This model was linked to a macroscale finite element model to predict post-peak strain softening in composite materials. Although a mesh objective theory was implemented at the microscale, it does not preclude pathological mesh dependence at the macroscale. To ensure mesh objectivity at both scales, the energy density and the energy release rate must be preserved identically across the two scales. This requires a consistent characteristic length or localization limiter. The effects of scaling (or not scaling) the dimensions of the microscale repeating unit cell (RUC), according to the macroscale element size, in a multiscale analysis was investigated using two examples. Additionally, the ramifications of the macroscale element shape, compared to the RUC, was studied.
Page, P C; Labuschagne, K; Venter, G J; Schoeman, J P; Guthrie, A J
2014-06-16
The efficacy of untreated and alphacypermethrin-treated high density polyethylene (HDPE) mesh against Culicoides biting midges (Diptera: Ceratopogonidae) was determined using Onderstepoort downdraught black light traps and a contact bioassay. Three traps were operated overnight in four replicates of a 3×3 randomised Latin square design near horses under South African field conditions. Both the untreated and alphacypermethrin-treated HDPE mesh significantly (P<0.05) reduced the numbers of Culicoides midges, predominantly Culicoides (Avaritia) imicola Kieffer, collected in the light traps by 4.2 and 7.2 times, respectively. A repellent effect of the alphacypermethrin-treated mesh was not confirmed because the number of midges collected in the light traps with untreated and alphacypermethrin-treated HDPE mesh was not significantly different (P=0.656). Bioassay of the insecticidal contact efficacy indicated median C. imicola mortality of 100% from 30 and 10 min following exposure to the alphacypermethrin-treated HDPE mesh for 1 or 3 min, respectively. In the bioassay, mortality was significantly higher (P=0.016) at 5 min post exposure in the midges exposed to the alphacypermethrin-treated mesh for 3 min (74.8%) compared to the 1 min exposure group (59.5%). The HDPE mesh could be used to reduce exposure of housed animals to Culicoides midges, specifically C. imicola, and viruses transmitted by these midges. Mesh treated with alphacypermethrin had the additional benefit of a rapid insecticidal effect on C. imicola. Copyright © 2014 Elsevier B.V. All rights reserved.
Nune, K C; Kumar, A; Murr, L E; Misra, R D K
2016-02-01
Three-dimensional cellular scaffolds are receiving significant attention in bone tissue engineering to treat segmental bone defects. However, there are indications of lack of significant osteoinductive ability of three-dimensional cellular scaffolds. In this regard, the objective of the study is to elucidate the interplay between bone morphogenetic protein (BMP-2) and osteoblast functions on 3D mesh structures with different porosities and pore size that were fabricated by electron beam melting. Self-assembled dendritic microstructure with interconnected cellular-type morphology of BMP-2 on 3D scaffolds stimulated osteoblast functions including adhesion, proliferation, and mineralization, with prominent effect on 2-mm mesh. Furthermore, immunofluorescence studies demonstrated higher density and viability of osteoblasts on lower porosity mesh structure (2 mm) as compared to 3- and 4-mm mesh structures. Enhanced filopodia cellular extensions with extensive cell spreading was observed on BMP-2 treated mesh structures, a behavior that is attributed to the unique self-assembled structure of BMP-2 that effectively communicates with the cells. The study underscores the potential of BMP-2 in imparting osteoinductive capability to the 3D printed scaffolds. © 2015 Wiley Periodicals, Inc.
Rakhmatia, Yunia Dwi; Ayukawa, Yasunori; Furuhashi, Akihiro; Koyano, Kiyoshi
2014-01-01
The objective of this study was to evaluate the optimal thickness and porosity of novel titanium mesh membranes to enhance bone augmentation, prevent soft tissue ingrowth, and prevent membrane exposure. Six types of novel titanium meshes with different thicknesses and pore sizes, along with three commercially available membranes, were used to cover surgically created calvarial defects in 6-week-old Sprague-Dawley rats. The animals were killed after 4 or 8 weeks. Microcomputed tomographic analyses were performed to analyze the three-dimensional bone volume and bone mineral density. Soft tissue ingrowth was also evaluated histologically and histomorphometrically. The novel titanium membranes used in this study were as effective at augmenting bone in the rat calvarial defect model as the commercially available membranes. The greatest bone volume was observed on 100-μm-thick membranes with larger pores, although these membranes promoted growth of bone with lower mineral density. Soft tissue ingrowth when 100-μm membranes were used was increased at 4 weeks but decreased again by 8 weeks to a level not statistically significantly different from other membranes. Membrane thickness affects the total amount of new bone formation, and membrane porosity is an essential factor for guided bone regeneration, especially during the initial healing period, although the final bone volume obtained is essentially the same. Newly developed titanium mesh membranes of 100 μm in thickness and with large pores appear to be optimal for guided bone regeneration.
An Idealized, Single Radial Swirler, Lean-Direct-Injection (LDI) Concept Meshing Script
NASA Technical Reports Server (NTRS)
Iannetti, Anthony C.; Thompson, Daniel
2008-01-01
To easily study combustor design parameters using computational fluid dynamics codes (CFD), a Gridgen Glyph-based macro (based on the Tcl scripting language) dubbed BladeMaker has been developed for the meshing of an idealized, single radial swirler, lean-direct-injection (LDI) combustor. BladeMaker is capable of taking in a number of parameters, such as blade width, blade tilt with respect to the perpendicular, swirler cup radius, and grid densities, and producing a three-dimensional meshed radial swirler with a can-annular (canned) combustor. This complex script produces a data format suitable for but not specific to the National Combustion Code (NCC), a state-of-the-art CFD code developed for reacting flow processes.
Dynamic mesh for TCAD modeling with ECORCE
NASA Astrophysics Data System (ADS)
Michez, A.; Boch, J.; Touboul, A.; Saigné, F.
2016-08-01
Mesh generation for TCAD modeling is challenging. Because densities of carriers can change by several orders of magnitude in thin areas, a significant change of the solution can be observed for two very similar meshes. The mesh must be defined at best to minimize this change. To address this issue, a criterion based on polynomial interpolation on adjacent nodes is proposed that adjusts accurately the mesh to the gradients of Degrees of Freedom. Furthermore, a dynamic mesh that follows changes of DF in DC and transient mode is a powerful tool for TCAD users. But, in transient modeling, adding nodes to a mesh induces oscillations in the solution that appears as spikes at the current collected at the contacts. This paper proposes two schemes that solve this problem. Examples show that using these techniques, the dynamic mesh generator of the TCAD tool ECORCE handle semiconductors devices in DC and transient mode.
Murr, L E; Gaytan, S M; Medina, F; Lopez, H; Martinez, E; Machado, B I; Hernandez, D H; Martinez, L; Lopez, M I; Wicker, R B; Bracke, J
2010-04-28
In this paper, we examine prospects for the manufacture of patient-specific biomedical implants replacing hard tissues (bone), particularly knee and hip stems and large bone (femoral) intramedullary rods, using additive manufacturing (AM) by electron beam melting (EBM). Of particular interest is the fabrication of complex functional (biocompatible) mesh arrays. Mesh elements or unit cells can be divided into different regions in order to use different cell designs in different areas of the component to produce various or continually varying (functionally graded) mesh densities. Numerous design elements have been used to fabricate prototypes by AM using EBM of Ti-6Al-4V powders, where the densities have been compared with the elastic (Young) moduli determined by resonant frequency and damping analysis. Density optimization at the bone-implant interface can allow for bone ingrowth and cementless implant components. Computerized tomography (CT) scans of metal (aluminium alloy) foam have also allowed for the building of Ti-6Al-4V foams by embedding the digital-layered scans in computer-aided design or software models for EBM. Variations in mesh complexity and especially strut (or truss) dimensions alter the cooling and solidification rate, which alters the alpha-phase (hexagonal close-packed) microstructure by creating mixtures of alpha/alpha' (martensite) observed by optical and electron metallography. Microindentation hardness measurements are characteristic of these microstructures and microstructure mixtures (alpha/alpha') and sizes.
NASA Astrophysics Data System (ADS)
Helwani, Z.; Fatra, W.; Arifin, L.; Othman, M. R.; Syapsan
2018-04-01
In this study, the manual hydraulic press was designed to prepare the briquettes from selected biomass waste. Each biomass was sun-dried and milled into small particle sizes before mixing with crude glycerol that used as a biomass binder. The effects of applied pressure levels of 100, 110, 120 bars, the particle size of 60, 80 and 100 mesh and the binder composition on the density, compressive strength and calorific heating value of the prepared briquettes were investigated using response surface methodology (RSM). Results showed that the briquettes have an average inside diameter, average outside diameter, and height of 12, 38, and 25-30 mm, respectively. The density of the briquettes increased with increasing the applied pressure, was in the range of 623-923 kg/m3. The densest briquettes were obtained at 80 mesh of particle size, 53:47 binder composition ratio and 110 bars of pressurizing. The heating value of the briquette reached up to 28.99 MJ/kg obtained on the particle size of 80 mesh, 53:47 binder composition, and 110 bars and the best compressive strength of 6.991 kg/cm2 obtained at a particle size of 100 mesh, 60:40 binder composition, and 120 bars. Process conditions influence the calorific value significantly.
Canopy Density Mapping on Ultracam-D Aerial Imagery in Zagros Woodlands, Iran
NASA Astrophysics Data System (ADS)
Erfanifard, Y.; Khodaee, Z.
2013-09-01
Canopy density maps express different characteristics of forest stands, especially in woodlands. Obtaining such maps by field measurements is so expensive and time-consuming. It seems necessary to find suitable techniques to produce these maps to be used in sustainable management of woodland ecosystems. In this research, a robust procedure was suggested to obtain these maps by very high spatial resolution aerial imagery. It was aimed to produce canopy density maps by UltraCam-D aerial imagery, newly taken in Zagros woodlands by Iran National Geographic Organization (NGO), in this study. A 30 ha plot of Persian oak (Quercus persica) coppice trees was selected in Zagros woodlands, Iran. The very high spatial resolution aerial imagery of the plot purchased from NGO, was classified by kNN technique and the tree crowns were extracted precisely. The canopy density was determined in each cell of different meshes with different sizes overlaid on the study area map. The accuracy of the final maps was investigated by the ground truth obtained by complete field measurements. The results showed that the proposed method of obtaining canopy density maps was efficient enough in the study area. The final canopy density map obtained by a mesh with 30 Ar (3000 m2) cell size had 80% overall accuracy and 0.61 KHAT coefficient of agreement which shows a great agreement with the observed samples. This method can also be tested in other case studies to reveal its capability in canopy density map production in woodlands.
NASA Astrophysics Data System (ADS)
Wu, Shijia; He, Weihua; Yang, Wulin; Ye, Yaoli; Huang, Xia; Logan, Bruce E.
2017-07-01
Microbial fuel cells (MFCs) need to have a compact architecture, but power generation using low strength domestic wastewater is unstable for closely-spaced electrode designs using thin anodes (flat mesh or small diameter graphite fiber brushes) due to oxygen crossover from the cathode. A composite anode configuration was developed to improve performance, by joining the mesh and brushes together, with the mesh used to block oxygen crossover to the brushes, and the brushes used to stabilize mesh potentials. In small, fed-batch MFCs (28 mL), the composite anode produced 20% higher power densities than MFCs using only brushes, and 150% power densities compared to carbon mesh anodes. In continuous flow tests at short hydraulic retention times (HRTs, 2 or 4 h) using larger MFCs (100 mL), composite anodes had stable performance, while brush anode MFCs exhibited power overshoot in polarization tests. Both configurations exhibited power overshoot at a longer HRT of 8 h due to lower effluent CODs. The use of composite anodes reduced biomass growth on the cathode (1.9 ± 0.2 mg) compared to only brushes (3.1 ± 0.3 mg), and increased coulombic efficiencies, demonstrating that they successfully reduced oxygen contamination of the anode and the bio-fouling of cathode.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei, Zi-an; Ma, J. X., E-mail: jxma@ustc.edu.cn
Ion sheaths formed in the up- and downstream sides of a negatively biased metal plate/mesh in an ion-beam-background-plasma system were experimentally investigated in a double plasma device. Measured potential profiles near the plate exhibit asymmetric structure, showing thicker sheath in the downstream side. The presence of the ion beam causes the shrink of the sheaths on both sides. The sheath thickness decreases with the increase of beam energy and density. Furthermore, the sheaths near the mesh are substantially thinner than that near the plate because of the partial transmission of the mesh to the ions. In addition, the increase ofmore » neutral gas pressure leads to the reduction of the beam energy and density, resulting in the increase of the sheath thickness.« less
Decay of grid turbulence in superfluid helium-4: Mesh dependence
NASA Astrophysics Data System (ADS)
Yang, J.; Ihas, G. G.
2018-03-01
Temporal decay of grid turbulence is experimentally studied in superfluid 4He in a large square channel. The second sound attenuation method is used to measure the turbulent vortex line density (L) with a phase locked tracking technique to minimize frequency shift effects induced by temperature fluctuations. Two different grids (0.8 mm and 3.0 mm mesh) are pulled to generate turbulence. Different power laws for decaying behavior are predicted by a theory. According to this theory, L should decay as t‑11/10 when the length scale of energy containing eddies grows from the grid mesh size to the size of the channel. At later time, after the energy containing eddy size becomes comparable to the channel, L should follow t‑3/2. Our recent experimental data exhibit evidence for t‑11/10 during the early time and t‑2 instead of t‑3/2 for later time. Moreover, a consistent bump/plateau feature is prominent between the two decay regimes for smaller (0.8 mm) grid mesh holes but absent with a grid mesh hole of 3.0 mm. This implies that in the large channel different types of turbulence are generated, depending on mesh hole size (mesh Reynolds number) compared to channel Reynolds number.
Huang, W.; Zheng, Lingyun; Zhan, X.
2002-01-01
Accurate modelling of groundwater flow and transport with sharp moving fronts often involves high computational cost, when a fixed/uniform mesh is used. In this paper, we investigate the modelling of groundwater problems using a particular adaptive mesh method called the moving mesh partial differential equation approach. With this approach, the mesh is dynamically relocated through a partial differential equation to capture the evolving sharp fronts with a relatively small number of grid points. The mesh movement and physical system modelling are realized by solving the mesh movement and physical partial differential equations alternately. The method is applied to the modelling of a range of groundwater problems, including advection dominated chemical transport and reaction, non-linear infiltration in soil, and the coupling of density dependent flow and transport. Numerical results demonstrate that sharp moving fronts can be accurately and efficiently captured by the moving mesh approach. Also addressed are important implementation strategies, e.g. the construction of the monitor function based on the interpolation error, control of mesh concentration, and two-layer mesh movement. Copyright ?? 2002 John Wiley and Sons, Ltd.
NASA Astrophysics Data System (ADS)
Breier, A.; Bittrich, L.; Hahn, J.; Spickenheuer, A.
2017-10-01
For the sustainable repair of abdominal wall hernia the application of hernia meshes is required. One reason for the relapse of hernia after surgery is seen in an inadequate adaption of the mechanical properties of the mesh to the movements of the abdominal wall. Differences in the stiffness of the mesh and the abdominal tissue cause tension, friction and stress resulting in a deficient tissue response and subsequently in a recurrence of a hernia, preferentially in the marginal area of the mesh. Embroidery technology enables a targeted influence on the mechanical properties of the generated textile structure by a directed thread deposition. Textile parameters like stitch density, alignment and angle can be changed easily and locally in the embroidery pattern to generate a space-resolved mesh with mechanical properties adapted to the requirement of the surrounding tissue. To determine those requirements the movements of the abdominal wall and the resulting distortions need to be known. This study was conducted to gain optical data of the abdominal wall movements by non-invasive ARAMIS-measurement on 39 test persons to estimate direction and value of the major strains.
Mesh-size effects on drift sample composition as determined with a triple net sampler
Slack, K.V.; Tilley, L.J.; Kennelly, S.S.
1991-01-01
Nested nets of three different mesh apertures were used to study mesh-size effects on drift collected in a small mountain stream. The innermost, middle, and outermost nets had, respectively, 425 ??m, 209 ??m and 106 ??m openings, a design that reduced clogging while partitioning collections into three size groups. The open area of mesh in each net, from largest to smallest mesh opening, was 3.7, 5.7 and 8.0 times the area of the net mouth. Volumes of filtered water were determined with a flowmeter. The results are expressed as (1) drift retained by each net, (2) drift that would have been collected by a single net of given mesh size, and (3) the percentage of total drift (the sum of the catches from all three nets) that passed through the 425 ??m and 209 ??m nets. During a two day period in August 1986, Chironomidae larvae were dominant numerically in all 209 ??m and 106 ??m samples and midday 425 ??m samples. Large drifters (Ephemerellidae) occurred only in 425 ??m or 209 ??m nets, but the general pattern was an increase in abundance and number of taxa with decreasing mesh size. Relatively more individuals occurred in the larger mesh nets at night than during the day. The two larger mesh sizes retained 70% of the total sediment/detritus in the drift collections, and this decreased the rate of clogging of the 106 ??m net. If an objective of a sampling program is to compare drift density or drift rate between areas or sampling dates, the same mesh size should be used for all sample collection and processing. The mesh aperture used for drift collection should retain all species and life stages of significance in a study. The nested net design enables an investigator to test the adequacy of drift samples. ?? 1991 Kluwer Academic Publishers.
Small herbivores suppress algal accumulation on Agatti atoll, Indian Ocean
NASA Astrophysics Data System (ADS)
Cernohorsky, Nicole H.; McClanahan, Timothy R.; Babu, Idrees; Horsák, Michal
2015-12-01
Despite large herbivorous fish being generally accepted as the main group responsible for preventing algal accumulation on coral reefs, few studies have experimentally examined the relative importance of herbivore size on algal communities. This study used exclusion cages with two different mesh sizes (1 × 1 cm and 6 × 6 cm) to investigate the impact of different-sized herbivores on algal accumulation rates on the shallow (<2 m) back-reef of Agatti atoll, Lakshadweep. The fine-mesh cages excluded all visible herbivores, which had rapid and lasting effects on the benthic communities, and, after 127 d of deployment, there was a visible and significant increase in algae (mainly macroalgae) with algal volume being 13 times greater than in adjacent open areas. The coarse-mesh cages excluded larger fishes (>8 cm body depth) while allowing smaller fishes to access the plots. In contrast to the conclusions of most previous studies, the exclusion of large herbivores had no significant effect on the accumulation of benthic algae and the amount of algae present within the coarse-mesh cages was relatively consistent throughout the experimental period (around 50 % coverage and 1-2 mm height). The difference in algal accumulation between the fine-mesh and coarse-mesh cages appears to be related to the actions of small individuals from 12 herbivorous fish species (0.17 ind. m-2 and 7.7 g m-2) that were able to enter through the coarse mesh. Although restricted to a single habitat, these results suggest that when present in sufficient densities and diversity, small herbivorous fishes can prevent the accumulation of algal biomass on coral reefs.
Unnikrishnan, Ginu U.; Morgan, Elise F.
2011-01-01
Inaccuracies in the estimation of material properties and errors in the assignment of these properties into finite element models limit the reliability, accuracy, and precision of quantitative computed tomography (QCT)-based finite element analyses of the vertebra. In this work, a new mesh-independent, material mapping procedure was developed to improve the quality of predictions of vertebral mechanical behavior from QCT-based finite element models. In this procedure, an intermediate step, called the material block model, was introduced to determine the distribution of material properties based on bone mineral density, and these properties were then mapped onto the finite element mesh. A sensitivity study was first conducted on a calibration phantom to understand the influence of the size of the material blocks on the computed bone mineral density. It was observed that varying the material block size produced only marginal changes in the predictions of mineral density. Finite element (FE) analyses were then conducted on a square column-shaped region of the vertebra and also on the entire vertebra in order to study the effect of material block size on the FE-derived outcomes. The predicted values of stiffness for the column and the vertebra decreased with decreasing block size. When these results were compared to those of a mesh convergence analysis, it was found that the influence of element size on vertebral stiffness was less than that of the material block size. This mapping procedure allows the material properties in a finite element study to be determined based on the block size required for an accurate representation of the material field, while the size of the finite elements can be selected independently and based on the required numerical accuracy of the finite element solution. The mesh-independent, material mapping procedure developed in this study could be particularly helpful in improving the accuracy of finite element analyses of vertebroplasty and spine metastases, as these analyses typically require mesh refinement at the interfaces between distinct materials. Moreover, the mapping procedure is not specific to the vertebra and could thus be applied to many other anatomic sites. PMID:21823740
NASA Astrophysics Data System (ADS)
Zhao, Yichao; Xiao, Xinyan; Ye, Zhihao; Ji, Qiang; Xie, Wei
2018-02-01
A mechanical durable superhydrophobic copper-plated stainless steel mesh was successfully fabricated by an electrodeposition process and 1-octadecanethiol modification. The as-prepared superhydrophobic mesh displays water contact angle of 153° and shows excellent anti-corrosion and water-oil separation properties in the condition of 0.1 A/cm2 current density for 35 s. In comparison with bare stainless steel mesh, the corrosion current of the as-prepared superhydrophobic mesh is close to 1/6 of the former. Meanwhile, the as-prepared superhydrophobic mesh could continuously separate oil from oil-water mixtures. The separation efficiency of continuous separation is as high as 96% and shows less than 1% decrease after ten cycles.
2012-02-01
x Approved for public release; distribution unlimited. I-DEAS/ TMG Thermal analysis software IR Initial Review ITAR International Traffic in Arms...the finite element code I- DEAS/ TMG . A mesh refinement study was conducted on the first panel to determine the mesh density required to accurately...ng neer ng, pera ons ec no ogy oe ng esearc ec no ogy • heat transfer analysis conducted with I-DEAS/ TMG exercises mapping of temperatures to
Adaptive Mesh Refinement for Microelectronic Device Design
NASA Technical Reports Server (NTRS)
Cwik, Tom; Lou, John; Norton, Charles
1999-01-01
Finite element and finite volume methods are used in a variety of design simulations when it is necessary to compute fields throughout regions that contain varying materials or geometry. Convergence of the simulation can be assessed by uniformly increasing the mesh density until an observable quantity stabilizes. Depending on the electrical size of the problem, uniform refinement of the mesh may be computationally infeasible due to memory limitations. Similarly, depending on the geometric complexity of the object being modeled, uniform refinement can be inefficient since regions that do not need refinement add to the computational expense. In either case, convergence to the correct (measured) solution is not guaranteed. Adaptive mesh refinement methods attempt to selectively refine the region of the mesh that is estimated to contain proportionally higher solution errors. The refinement may be obtained by decreasing the element size (h-refinement), by increasing the order of the element (p-refinement) or by a combination of the two (h-p refinement). A successful adaptive strategy refines the mesh to produce an accurate solution measured against the correct fields without undue computational expense. This is accomplished by the use of a) reliable a posteriori error estimates, b) hierarchal elements, and c) automatic adaptive mesh generation. Adaptive methods are also useful when problems with multi-scale field variations are encountered. These occur in active electronic devices that have thin doped layers and also when mixed physics is used in the calculation. The mesh needs to be fine at and near the thin layer to capture rapid field or charge variations, but can coarsen away from these layers where field variations smoothen and charge densities are uniform. This poster will present an adaptive mesh refinement package that runs on parallel computers and is applied to specific microelectronic device simulations. Passive sensors that operate in the infrared portion of the spectrum as well as active device simulations that model charge transport and Maxwell's equations will be presented.
NASA Astrophysics Data System (ADS)
Tao, Y. B.; Liu, Y. W.; Gao, F.; Chen, X. Y.; He, Y. L.
2009-09-01
An anisotropic porous media model for mesh regenerator used in pulse tube refrigerator (PTR) is established. Formulas for permeability and Forchheimer coefficient are derived which include the effects of regenerator configuration and geometric parameters, oscillating flow, operating frequency, cryogenic temperature. Then, the fluid flow and heat transfer performances of mesh regenerator are numerically investigated under different mesh geometric parameters and material properties. The results indicate that the cooling power of the PTR increases with the increases of specific heat capacity and density of the regenerator mesh material, and decreases with the increases of penetration depth and thermal conductivity ratio ( a). The cooling power at a = 0.1 is 0.5-2.0 W higher than that at a = 1. Optimizing the filling scale of different mesh configurations (such as 75% #200 twill and 25% #250 twill) and adopting multi segments regenerator with stainless steel meshes at the cold end can enhance the regenerator's efficiency and achieve better heat transfer performance.
Highly flexible transparent electrodes based on mesh-patterned rigid indium tin oxide.
Sakamoto, Kosuke; Kuwae, Hiroyuki; Kobayashi, Naofumi; Nobori, Atsuki; Shoji, Shuichi; Mizuno, Jun
2018-02-12
We developed highly bendable transparent indium tin oxide (ITO) electrodes with a mesh pattern for use in flexible electronic devices. The mesh patterns lowered tensile stress and hindered propagation of cracks. Simulations using the finite element method confirmed that the mesh patterns decreased tensile stress by over 10% because of the escaped strain to the flexible film when the electrodes were bent. The proposed patterned ITO electrodes were simply fabricated by photolithography and wet etching. The resistance increase ratio of a mesh-patterned ITO electrode after bending 1000 times was at least two orders of magnitude lower than that of a planar ITO electrode. In addition, crack propagation was stopped by the mesh pattern of the patterned ITO electrode. A mesh-patterned ITO electrode was used in a liquid-based organic light-emitting diode (OLED). The OLED displayed the same current density-voltage-luminance (J-V-L) curves before and after bending 100 times. These results indicate that the developed mesh-patterned ITO electrodes are attractive for use in flexible electronic devices.
On Spurious Numerics in Solving Reactive Equations
NASA Technical Reports Server (NTRS)
Kotov, D. V; Yee, H. C.; Wang, W.; Shu, C.-W.
2013-01-01
The objective of this study is to gain a deeper understanding of the behavior of high order shock-capturing schemes for problems with stiff source terms and discontinuities and on corresponding numerical prediction strategies. The studies by Yee et al. (2012) and Wang et al. (2012) focus only on solving the reactive system by the fractional step method using the Strang splitting (Strang 1968). It is a common practice by developers in computational physics and engineering simulations to include a cut off safeguard if densities are outside the permissible range. Here we compare the spurious behavior of the same schemes by solving the fully coupled reactive system without the Strang splitting vs. using the Strang splitting. Comparison between the two procedures and the effects of a cut off safeguard is the focus the present study. The comparison of the performance of these schemes is largely based on the degree to which each method captures the correct location of the reaction front for coarse grids. Here "coarse grids" means standard mesh density requirement for accurate simulation of typical non-reacting flows of similar problem setup. It is remarked that, in order to resolve the sharp reaction front, local refinement beyond standard mesh density is still needed.
Kishan, Alysha; Walker, Taneidra; Sears, Nick; Wilems, Thomas; Cosgriff-Hernandez, Elizabeth
2018-05-01
To better mimic native tissue microenvironments, current efforts have moved beyond single growth factor delivery to more complex multiple growth factor delivery with distinct release profiles. Electrospun gelatin, a widely investigated drug delivery vehicle, requires postprocessing crosslinking techniques that generate a mesh with uniform crosslinking density, limiting the ability to deliver multiple factors at different rates. Herein, we describe a method to independently control release of multiple factors from a single electrospun gelatin mesh. Two in situ crosslinking modalities, photocrosslinking of methacyrlated gelatin and reactive crosslinking of gelatin with a diisocyanate, are coelectrospun to generate distinct fiber populations with different crosslinking chemistry and density in a single mesh. The photocrosslinked gelatin-methacrylate resulted in a relatively rapid release of a model protein (48 ± 12% at day 1, 96 ± 3% at day 10) due to diffusion of embedded protein from the crosslinked fibers. The reactive crosslinking system displayed a more sustained release (7 ± 5% at day 1, 33 ± 2% at day 10) that was attributed to the conjugation of protein to gelatin with the diisocyanate, requiring degradation of gelatin prior to diffusion out of the fibers. Both modalities displayed tunable release profiles. Subsequent release studies of a cospun mesh with two different crosslinked fiber populations confirmed that the cospun mesh displayed multifactor release with independent release profiles. Overall, this bimodal, in situ crosslinking approach enables the delivery of multiple factors with distinct release kinetics from a single mesh and is expected to have broad utility in tissue engineering. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1155-1164, 2018. © 2018 Wiley Periodicals, Inc.
Junwei Ma; Han Yuan; Sunderam, Sridhar; Besio, Walter; Lei Ding
2017-07-01
Neural activity inside the human brain generate electrical signals that can be detected on the scalp. Electroencephalograph (EEG) is one of the most widely utilized techniques helping physicians and researchers to diagnose and understand various brain diseases. Due to its nature, EEG signals have very high temporal resolution but poor spatial resolution. To achieve higher spatial resolution, a novel tri-polar concentric ring electrode (TCRE) has been developed to directly measure Surface Laplacian (SL). The objective of the present study is to accurately calculate SL for TCRE based on a realistic geometry head model. A locally dense mesh was proposed to represent the head surface, where the local dense parts were to match the small structural components in TCRE. Other areas without dense mesh were used for the purpose of reducing computational load. We conducted computer simulations to evaluate the performance of the proposed mesh and evaluated possible numerical errors as compared with a low-density model. Finally, with achieved accuracy, we presented the computed forward lead field of SL for TCRE for the first time in a realistic geometry head model and demonstrated that it has better spatial resolution than computed SL from classic EEG recordings.
NASA Astrophysics Data System (ADS)
Delandmeter, Philippe; Lambrechts, Jonathan; Legat, Vincent; Vallaeys, Valentin; Naithani, Jaya; Thiery, Wim; Remacle, Jean-François; Deleersnijder, Eric
2018-03-01
The discontinuous Galerkin (DG) finite element method is well suited for the modelling, with a relatively small number of elements, of three-dimensional flows exhibiting strong velocity or density gradients. Its performance can be highly enhanced by having recourse to r-adaptivity. Here, a vertical adaptive mesh method is developed for DG finite elements. This method, originally designed for finite difference schemes, is based on the vertical diffusion of the mesh nodes, with the diffusivity controlled by the density jumps at the mesh element interfaces. The mesh vertical movement is determined by means of a conservative arbitrary Lagrangian-Eulerian (ALE) formulation. Though conservativity is naturally achieved, tracer consistency is obtained by a suitable construction of the mesh vertical velocity field, which is defined in such a way that it is fully compatible with the tracer and continuity equations at a discrete level. The vertically adaptive mesh approach is implemented in the three-dimensional version of the geophysical and environmental flow Second-generation Louvain-la-Neuve Ice-ocean Model (SLIM 3D; www.climate.be/slim). Idealised benchmarks, aimed at simulating the oscillations of a sharp thermocline, are dealt with. Then, the relevance of the vertical adaptivity technique is assessed by simulating thermocline oscillations of Lake Tanganyika. The results are compared to measured vertical profiles of temperature, showing similar stratification and outcropping events.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Staley, Martin
Metamesh is a general-purpose C++ library for creating "mesh" data structures from smaller parts. That is, rather than providing a traditional "mesh format," as many libraries do, or a GUI for building meshes, Metamesh provides tools by which the mesh structures themselves can be built. Consider that a mesh in up to three dimensions can contain nodes (0d entities), edges (1d), faces (2d), and cells (3d). Edges are typically defined from two nodes. Faces can be defined from nodes or edges; and cells from nodes, edges, or faces. Someone might also wish to allow for general faces or cells, ormore » for only a specific variant - say, triangular faces and tetrahedral cells. Moreover, a mesh can have the same or a lesser dimension than that of its enclosing space. In 3d, say, one could have a full 3d mesh, a 2d "sheet" mesh without cells, a 1d "string" mesh with neither faces nor cells, or even a 1d "point cloud." And, aside from the mesh structure itself, additional data might be wanted: velocities at nodes, say, or fluxes across faces, or an average density in each cell. Metamesh supports all of this, through C++ generics and template metaprogramming techniques. Users fit Metamesh constructs together to define a mesh layout, and Metamesh then automatically provides the newly constructed mesh with functionality. Metamesh also provides facilities for spinning, extruding, visualizing, and performing I/O of whatever meshes a user builds.« less
Shelter effect efficacy of sand fences: A comparison of systems in a wind tunnel
NASA Astrophysics Data System (ADS)
Wang, Tao; Qu, Jianjun; Ling, Yuquan; Liu, Benli; Xiao, Jianhua
2018-02-01
The Lanzhou-Xinjiang High-speed Railway runs through an expansive wind area in the Gobi Desert and blown-sand disasters are a critical issue affecting its operation. To strengthen the blown-sand disaster shelter systems along the railway, the shelter effects of punching plate and wire mesh fences with approximately equal porosity (48%) were simulated in a wind tunnel. The experimental results showed that the wind velocity was reduced to a higher extent by the punching plate fence than by the wire mesh fence. When a single row of sand fencing was used, the wind velocity reduction coefficient (Rcz) values downwind of the punching plate fence and wire mesh fence reached 71.77% and 39.37%, respectively. When double rows of sand fencing were used, the Rcz values downwind of the punching plate and wire mesh fences were approximately 87.48% and 60.81%, respectively. For the flow field structure on the leeward side of the fencing, the deceleration zone behind the punching plate fence was more pronounced than that behind the wire mesh fence. The vortex zone was not obvious and the reverse flow disappeared for both types of fences, which indicates that the turbulent intensity was small. The sand-trapping efficiency of the wire mesh fence was close to that of punching plate fence. When a single row of sand fencing was set up, the total mass flux density decreased, on average, by 65.85% downwind of the wire mesh fence, and 75.06% downwind of the punching plate fence; when double rows of sand fencing were present, the total mass flux density decreased, on average, by 84.53% downwind of the wire mesh fence and 84.51% downwind of the punching plate fence. In addition, the wind-proof efficiency and the sand-proof efficiency of the punching plate fence and the wire mesh fence decreased with increasing wind velocities. Consequently, punching plate and wire mesh fences may effectively control the sand hazard in the expansive wind area of the Gobi Desert.
Causes of declining survival of lake trout stocked in U.S. waters of Lake Superior in 1963-1986
Hansen, Michael J.; Ebener, Mark P.; Schorfhaar, Richard G.; Schram, Stephen T.; Schreiner, Donald R.; Selgeby, James H.; Taylor, William W.
1996-01-01
Survival of the 1963-1982 year-classes of stocked yearling lake trout Salvelinus namaycush declined significantly over time in Lake Superior. To investigate possible causes of this decline, a Ricker model of stock-recruitment was used to describe the catch per effort (CPE) of age-7 stocked lake trout in the Michigan, Minnesota, and Wisconsin waters of Lake Superior as functions of the numbers of yearlings stocked 6 years earlier (an index of density dependence), the density (CPE) of wild adult lake trout (an index of predation), and large-mesh (a?Y 114-mm stretch-measure) gill-net fishing effort (an index of fishing mortality). Declining CPE of stocked lake trout in Michigan and Wisconsin was significantly associated with increasing large-mesh gillnet fishing effort. Declining CPE of stocked lake trout in Minnesota was significantly associated with increasing density of wild lake trout. Declining survival of stocked lake trout may therefore have been caused by increased mortality in large-mesh gill-net fisheries in Michigan and Wisconsin, and by predation by wild lake trout that recently recolonized the Minnesota area. We recommend that experimental management be pursued to determine the relative importance of large-mesh gillnet fishing effort and of predation by wild lake trout on the survival of stocked lake trout in U.S. waters of Lake Superior.
Mesh refinement in a two-dimensional large eddy simulation of a forced shear layer
NASA Technical Reports Server (NTRS)
Claus, R. W.; Huang, P. G.; Macinnes, J. M.
1989-01-01
A series of large eddy simulations are made of a forced shear layer and compared with experimental data. Several mesh densities were examined to separate the effect of numerical inaccuracy from modeling deficiencies. The turbulence model that was used to represent small scale, 3-D motions correctly predicted some gross features of the flow field, but appears to be structurally incorrect. The main effect of mesh refinement was to act as a filter on the scale of vortices that developed from the inflow boundary conditions.
Adaptive, Tactical Mesh Networking: Control Base MANET Model
2010-09-01
pp. 316–320 Available: IEEE Xplore , http://ieeexplore.ieee.org [Accessed: June 9, 2010]. [5] N. Sidiropoulos, “Multiuser Transmit Beamforming...Mobile Mesh Segments of TNT Testbed .......... 11 Figure 5. Infrastructure and Ad Hoc Mode of IEEE 802.11................................ 13 Figure...6. The Power Spectral Density of OFDM................................................ 14 Figure 7. A Typical IEEE 802.16 Network
Simon, David D; Andrews, Sharon M; Robinson-Zeigler, Rebecca; Valdes, Thelma; Woods, Terry O
2018-02-01
Current mechanical testing of surgical mesh focuses primarily on tensile properties even though implanted devices are not subjected to pure tensile loads. Our objective was to determine the flexural (bending) properties of surgical mesh and determine if they correlate with mesh tensile properties. The flexural rigidity values of 11 different surgical mesh designs were determined along three textile directions (machine, cross-machine, and 45° to machine; n = 5 for each) using ASTM D1388-14 while tracking surface orientation. Tensile testing was also performed on the same specimens using ASTM D882-12. Linear regressions were performed to compare mesh flexural rigidity to mesh thickness, areal mass density, filament diameter, ultimate tensile strength, and maximum extension. Of 33 mesh specimen groups, 30 had significant differences in flexural rigidity values when comparing surface orientations (top and bottom). Flexural rigidity and mesh tensile properties also varied with textile direction (machine and cross-machine). There was no strong correlation between the flexural and tensile properties, with mesh thickness having the best overall correlation with flexural rigidity. Currently, surface orientation is not indicated on marketed surgical mesh, and a single mesh may behave differently depending on the direction of loading. The lack of correlation between flexural stiffness and tensile properties indicates the need to examine mesh bending stiffness to provide a more comprehensive understanding of surgical mesh mechanical behaviors. Further investigation is needed to determine if these flexural properties result in the surgical mesh behaving mechanically different depending on implantation direction. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 854-862, 2018. © 2017 Wiley Periodicals, Inc.
Three distinct modes in a surface micro-discharge in atmospheric pressure He + N{sub 2} mixtures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Dong; Liu, Dingxin, E-mail: liudingxin@mail.xjtu.edu.cn; He, Tongtong
2015-12-15
A surface micro-discharge in atmospheric pressure He + N{sub 2} mixtures is studied in this paper with an emphasis on the discharge modes. With the N{sub 2} admixture increasing from 0.1% to 20%, the discharge evolves from a spatially diffuse mode to a filamentary mode during positive half-cycles of the applied voltage. However during the negative half-cycles, an additional patterned mode emerges between the diffuse and the filamentary modes, which has not been reported before to exist in surface micro-discharges. In the diffuse and patterned modes, the plasmas cover almost the entirety of the mesh area during one cycle after plasma ignitionmore » in all mesh elements, and the discharge power increases linearly with the applied voltage. In contrast, plasma coverage of the mesh area is only partial in the filamentary mode and the plasma is more unstable with the discharge power increasing exponentially with the applied voltage. As the surface micro-discharge evolves through the three modes, the density of excited species changes significantly, for instance, the density of N{sub 2}{sup +}(B) drops by ∼20-fold from [N{sub 2}] = 0.2% to 20%. The N{sub 2}{sup +}(B) is predicted to be generated mainly through successive processes of Penning ionization by helium metastables and electron-impact excitation of N{sub 2}{sup +}(X), the latter is most responsible for the density decrease of N{sub 2}{sup +}(B) because much more N{sub 2}{sup +}(X) is converted to N{sub 4}{sup +}(X) as the increase of N{sub 2} fraction. Also, the electron density and electron temperature decrease with the discharge mode transition.« less
Facial expression reconstruction on the basis of selected vertices of triangle mesh
NASA Astrophysics Data System (ADS)
Peszor, Damian; Wojciechowska, Marzena
2016-06-01
Facial expression reconstruction is an important issue in the field of computer graphics. While it is relatively easy to create an animation based on meshes constructed through video recordings, this kind of high-quality data is often not transferred to another model because of lack of intermediary, anthropometry-based way to do so. However, if a high-quality mesh is sampled with sufficient density, it is possible to use obtained feature points to encode the shape of surrounding vertices in a way that can be easily transferred to another mesh with corresponding feature points. In this paper we present a method used for obtaining information for the purpose of reconstructing changes in facial surface on the basis of selected feature points.
NASA Astrophysics Data System (ADS)
Wu, Kailiang; Tang, Huazhong
2018-06-01
The paper studies the physical-constraints-preserving (PCP) schemes for multi-dimensional special relativistic magnetohydrodynamics with a general equation of state (EOS) on more general meshes. It is an extension of the work (Wu and Tang in Math. Models Methods Appl. Sci. 27:1871-1928, 2017) which focuses on the ideal EOS and uniform Cartesian meshes. The general EOS without a special expression poses some additional difficulties in discussing the mathematical properties of admissible state set with the physical constraints on the fluid velocity, density and pressure. Rigorous analyses are provided for the PCP property of finite volume or discontinuous Galerkin schemes with the Lax-Friedrichs (LxF)-type flux on a general mesh with non-self-intersecting polytopes. Those are built on a more general form of generalized LxF splitting property and a different convex decomposition technique. It is shown in theory that the PCP property is closely connected with a discrete divergence-free condition, which is proposed on the general mesh and milder than that in Wu and Tang (2017).
Promoting Wired Links in Wireless Mesh Networks: An Efficient Engineering Solution
Barekatain, Behrang; Raahemifar, Kaamran; Ariza Quintana, Alfonso; Triviño Cabrera, Alicia
2015-01-01
Wireless Mesh Networks (WMNs) cannot completely guarantee good performance of traffic sources such as video streaming. To improve the network performance, this study proposes an efficient engineering solution named Wireless-to-Ethernet-Mesh-Portal-Passageway (WEMPP) that allows effective use of wired communication in WMNs. WEMPP permits transmitting data through wired and stable paths even when the destination is in the same network as the source (Intra-traffic). Tested with four popular routing protocols (Optimized Link State Routing or OLSR as a proactive protocol, Dynamic MANET On-demand or DYMO as a reactive protocol, DYMO with spanning tree ability and HWMP), WEMPP considerably decreases the end-to-end delay, jitter, contentions and interferences on nodes, even when the network size or density varies. WEMPP is also cost-effective and increases the network throughput. Moreover, in contrast to solutions proposed by previous studies, WEMPP is easily implemented by modifying the firmware of the actual Ethernet hardware without altering the routing protocols and/or the functionality of the IP/MAC/Upper layers. In fact, there is no need for modifying the functionalities of other mesh components in order to work with WEMPPs. The results of this study show that WEMPP significantly increases the performance of all routing protocols, thus leading to better video quality on nodes. PMID:25793516
Ayturk, Ugur M; Puttlitz, Christian M
2011-08-01
The primary objective of this study was to generate a finite element model of the human lumbar spine (L1-L5), verify mesh convergence for each tissue constituent and perform an extensive validation using both kinematic/kinetic and stress/strain data. Mesh refinement was accomplished via convergence of strain energy density (SED) predictions for each spinal tissue. The converged model was validated based on range of motion, intradiscal pressure, facet force transmission, anterolateral cortical bone strain and anterior longitudinal ligament deformation predictions. Changes in mesh resolution had the biggest impact on SED predictions under axial rotation loading. Nonlinearity of the moment-rotation curves was accurately simulated and the model predictions on the aforementioned parameters were in good agreement with experimental data. The validated and converged model will be utilised to study the effects of degeneration on the lumbar spine biomechanics, as well as to investigate the mechanical underpinning of the contemporary treatment strategies.
Khan, Arshad; Lee, Sangeon; Jang, Taehee; Xiong, Ze; Zhang, Cuiping; Tang, Jinyao; Guo, L Jay; Li, Wen-Di
2016-06-01
A new structure of flexible transparent electrodes is reported, featuring a metal mesh fully embedded and mechanically anchored in a flexible substrate, and a cost-effective solution-based fabrication strategy for this new transparent electrode. The embedded nature of the metal-mesh electrodes provides a series of advantages, including surface smoothness that is crucial for device fabrication, mechanical stability under high bending stress, strong adhesion to the substrate with excellent flexibility, and favorable resistance against moisture, oxygen, and chemicals. The novel fabrication process replaces vacuum-based metal deposition with an electrodeposition process and is potentially suitable for high-throughput, large-volume, and low-cost production. In particular, this strategy enables fabrication of a high-aspect-ratio (thickness to linewidth) metal mesh, substantially improving conductivity without considerably sacrificing transparency. Various prototype flexible transparent electrodes are demonstrated with transmittance higher than 90% and sheet resistance below 1 ohm sq(-1) , as well as extremely high figures of merit up to 1.5 × 10(4) , which are among the highest reported values in recent studies. Finally using our embedded metal-mesh electrode, a flexible transparent thin-film heater is demonstrated with a low power density requirement, rapid response time, and a low operating voltage. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The ESA/MBB unfurlable mesh antenna development for mobile services
NASA Astrophysics Data System (ADS)
Kellermeier, H.; Vorbrugg, H.; Pontoppidan, K.; Eaton, D. C. G.
Mobile services via satellite in the 800-900 MHz frequency range have recently been studied by SPAR Aerospace Ltd in the M-SAT phase B using various unfurlable offset reflector concepts between 9 and 5 m aperture diameters for 6-, 4- and 2-beam coverage. For a 2-beam coverage of Canada and U.S.A. two offset antennas each of 5 m aperture diameter are required. The MBB offset unfurlable mesh antenna (UMA) developed since 1983 under an ESA contract is one of the attractive candidates: The design concept chosen uses foldable radial ribs of carbon fibre which deploy a gold plated molybdenum mesh on adjustable stand-offs. This concept is applicable for offset aperture diameters up to 12 m since the carbon fibre ribs are double folded and provide for a high package density when stowed at the spacecraft during launch. The electrical analysis performed by TICRA/Copenhagen was assisted by electrical measurements on mesh samples, verifying that main charactertics as ohmic resistance, transmission loss and passive intermodulation products (PIMP) lie within the required tolerances if the mesh is pretensioned to a certain configuration. For on-orbit testing and retrieval by the Shuttle the reflector shows a unique design feature of retractability by the reversable deployment sequence.
Practical implementation of tetrahedral mesh reconstruction in emission tomography
Boutchko, R.; Sitek, A.; Gullberg, G. T.
2014-01-01
This paper presents a practical implementation of image reconstruction on tetrahedral meshes optimized for emission computed tomography with parallel beam geometry. Tetrahedral mesh built on a point cloud is a convenient image representation method, intrinsically three-dimensional and with a multi-level resolution property. Image intensities are defined at the mesh nodes and linearly interpolated inside each tetrahedron. For the given mesh geometry, the intensities can be computed directly from tomographic projections using iterative reconstruction algorithms with a system matrix calculated using an exact analytical formula. The mesh geometry is optimized for a specific patient using a two stage process. First, a noisy image is reconstructed on a finely-spaced uniform cloud. Then, the geometry of the representation is adaptively transformed through boundary-preserving node motion and elimination. Nodes are removed in constant intensity regions, merged along the boundaries, and moved in the direction of the mean local intensity gradient in order to provide higher node density in the boundary regions. Attenuation correction and detector geometric response are included in the system matrix. Once the mesh geometry is optimized, it is used to generate the final system matrix for ML-EM reconstruction of node intensities and for visualization of the reconstructed images. In dynamic PET or SPECT imaging, the system matrix generation procedure is performed using a quasi-static sinogram, generated by summing projection data from multiple time frames. This system matrix is then used to reconstruct the individual time frame projections. Performance of the new method is evaluated by reconstructing simulated projections of the NCAT phantom and the method is then applied to dynamic SPECT phantom and patient studies and to a dynamic microPET rat study. Tetrahedral mesh-based images are compared to the standard voxel-based reconstruction for both high and low signal-to-noise ratio projection datasets. The results demonstrate that the reconstructed images represented as tetrahedral meshes based on point clouds offer image quality comparable to that achievable using a standard voxel grid while allowing substantial reduction in the number of unknown intensities to be reconstructed and reducing the noise. PMID:23588373
Practical implementation of tetrahedral mesh reconstruction in emission tomography
NASA Astrophysics Data System (ADS)
Boutchko, R.; Sitek, A.; Gullberg, G. T.
2013-05-01
This paper presents a practical implementation of image reconstruction on tetrahedral meshes optimized for emission computed tomography with parallel beam geometry. Tetrahedral mesh built on a point cloud is a convenient image representation method, intrinsically three-dimensional and with a multi-level resolution property. Image intensities are defined at the mesh nodes and linearly interpolated inside each tetrahedron. For the given mesh geometry, the intensities can be computed directly from tomographic projections using iterative reconstruction algorithms with a system matrix calculated using an exact analytical formula. The mesh geometry is optimized for a specific patient using a two stage process. First, a noisy image is reconstructed on a finely-spaced uniform cloud. Then, the geometry of the representation is adaptively transformed through boundary-preserving node motion and elimination. Nodes are removed in constant intensity regions, merged along the boundaries, and moved in the direction of the mean local intensity gradient in order to provide higher node density in the boundary regions. Attenuation correction and detector geometric response are included in the system matrix. Once the mesh geometry is optimized, it is used to generate the final system matrix for ML-EM reconstruction of node intensities and for visualization of the reconstructed images. In dynamic PET or SPECT imaging, the system matrix generation procedure is performed using a quasi-static sinogram, generated by summing projection data from multiple time frames. This system matrix is then used to reconstruct the individual time frame projections. Performance of the new method is evaluated by reconstructing simulated projections of the NCAT phantom and the method is then applied to dynamic SPECT phantom and patient studies and to a dynamic microPET rat study. Tetrahedral mesh-based images are compared to the standard voxel-based reconstruction for both high and low signal-to-noise ratio projection datasets. The results demonstrate that the reconstructed images represented as tetrahedral meshes based on point clouds offer image quality comparable to that achievable using a standard voxel grid while allowing substantial reduction in the number of unknown intensities to be reconstructed and reducing the noise.
The Aerogel Mesh Contamination Collector
1993-07-01
patent pending 2.1 Introduction The new method of contamination prevention and collection described herein employs ultra-low density silica aerogel and a... silica aerogel and the Section 2.2 presents the fabrication of the acrogel me:sh contamination collector (AMCC). The device is a heterostructure...monolithic photonic devices and lightweight optics). This report series will focus on silica aerogels almost exclusively. It is also of interest to note that
Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology
Fu, Tian-Ming; Hong, Guosong; Viveros, Robert D.; Zhou, Tao
2017-01-01
Implantable electrical probes have led to advances in neuroscience, brain−machine interfaces, and treatment of neurological diseases, yet they remain limited in several key aspects. Ideally, an electrical probe should be capable of recording from large numbers of neurons across multiple local circuits and, importantly, allow stable tracking of the evolution of these neurons over the entire course of study. Silicon probes based on microfabrication can yield large-scale, high-density recording but face challenges of chronic gliosis and instability due to mechanical and structural mismatch with the brain. Ultraflexible mesh electronics, on the other hand, have demonstrated negligible chronic immune response and stable long-term brain monitoring at single-neuron level, although, to date, it has been limited to 16 channels. Here, we present a scalable scheme for highly multiplexed mesh electronics probes to bridge the gap between scalability and flexibility, where 32 to 128 channels per probe were implemented while the crucial brain-like structure and mechanics were maintained. Combining this mesh design with multisite injection, we demonstrate stable 128-channel local field potential and single-unit recordings from multiple brain regions in awake restrained mice over 4 mo. In addition, the newly integrated mesh is used to validate stable chronic recordings in freely behaving mice. This scalable scheme for mesh electronics together with demonstrated long-term stability represent important progress toward the realization of ideal implantable electrical probes allowing for mapping and tracking single-neuron level circuit changes associated with learning, aging, and neurodegenerative diseases. PMID:29109247
NASA Astrophysics Data System (ADS)
Shen, Junyu; Wang, Mei; Zhao, Liang; Zhang, Peili; Jiang, Jian; Liu, Jinxuan
2018-06-01
The development of highly efficient, robust, and cheap water oxidation electrodes is a major challenge in constructing industrially applicable electrolyzers for large-scale production of hydrogen from water. Herein we report a hierarchical stainless steel mesh electrode which features Ni(Fe)OxHy-coated self-supported nanocone arrays. Through a facile, mild, low-cost and readily scalable two-step fabrication procedure, the electrochemically active area of the optimized electrode is enlarged by a factor of 3.1 and the specific activity is enhanced by a factor of 250 at 265 mV overpotential compared with that of a corresponding pristine stainless steel mesh electrode. Moreover, the charge-transfer resistance is reduced from 4.47 Ω for the stainless steel mesh electrode to 0.13 Ω for the Ni(Fe)OxHy-coated nanocone array stainless steel mesh electrode. As a result, the cheap and easily fabricated electrode displays 280 and 303 mV low overpotentials to achieve high current densities of 500 and 1000 mA cmgeo-2, respectively, for oxygen evolution reaction in 1 M KOH. More importantly, the electrode exhibits a good stability over 340 h of chronopotentiometric test at 50 mA cmgeo-2 and only a slight attenuation (4.2%, ∼15 mV) in catalytic activity over 82 h electrolysis at a constant current density of 500 mA cmgeo-2.
Quinoa - Adaptive Computational Fluid Dynamics, 0.2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bakosi, Jozsef; Gonzalez, Francisco; Rogers, Brandon
Quinoa is a set of computational tools that enables research and numerical analysis in fluid dynamics. At this time it remains a test-bed to experiment with various algorithms using fully asynchronous runtime systems. Currently, Quinoa consists of the following tools: (1) Walker, a numerical integrator for systems of stochastic differential equations in time. It is a mathematical tool to analyze and design the behavior of stochastic differential equations. It allows the estimation of arbitrary coupled statistics and probability density functions and is currently used for the design of statistical moment approximations for multiple mixing materials in variable-density turbulence. (2) Inciter,more » an overdecomposition-aware finite element field solver for partial differential equations using 3D unstructured grids. Inciter is used to research asynchronous mesh-based algorithms and to experiment with coupling asynchronous to bulk-synchronous parallel code. Two planned new features of Inciter, compared to the previous release (LA-CC-16-015), to be implemented in 2017, are (a) a simple Navier-Stokes solver for ideal single-material compressible gases, and (b) solution-adaptive mesh refinement (AMR), which enables dynamically concentrating compute resources to regions with interesting physics. Using the NS-AMR problem we plan to explore how to scale such high-load-imbalance simulations, representative of large production multiphysics codes, to very large problems on very large computers using an asynchronous runtime system. (3) RNGTest, a test harness to subject random number generators to stringent statistical tests enabling quantitative ranking with respect to their quality and computational cost. (4) UnitTest, a unit test harness, running hundreds of tests per second, capable of testing serial, synchronous, and asynchronous functions. (5) MeshConv, a mesh file converter that can be used to convert 3D tetrahedron meshes from and to either of the following formats: Gmsh, (http://www.geuz.org/gmsh), Netgen, (http://sourceforge.net/apps/mediawiki/netgen-mesher), ExodusII, (http://sourceforge.net/projects/exodusii), HyperMesh, (http://www.altairhyperworks.com/product/HyperMesh).« less
Mesh refinement in finite element analysis by minimization of the stiffness matrix trace
NASA Technical Reports Server (NTRS)
Kittur, Madan G.; Huston, Ronald L.
1989-01-01
Most finite element packages provide means to generate meshes automatically. However, the user is usually confronted with the problem of not knowing whether the mesh generated is appropriate for the problem at hand. Since the accuracy of the finite element results is mesh dependent, mesh selection forms a very important step in the analysis. Indeed, in accurate analyses, meshes need to be refined or rezoned until the solution converges to a value so that the error is below a predetermined tolerance. A-posteriori methods use error indicators, developed by using the theory of interpolation and approximation theory, for mesh refinements. Some use other criterions, such as strain energy density variation and stress contours for example, to obtain near optimal meshes. Although these methods are adaptive, they are expensive. Alternatively, a priori methods, until now available, use geometrical parameters, for example, element aspect ratio. Therefore, they are not adaptive by nature. An adaptive a-priori method is developed. The criterion is that the minimization of the trace of the stiffness matrix with respect to the nodal coordinates, leads to a minimization of the potential energy, and as a consequence provide a good starting mesh. In a few examples the method is shown to provide the optimal mesh. The method is also shown to be relatively simple and amenable to development of computer algorithms. When the procedure is used in conjunction with a-posteriori methods of grid refinement, it is shown that fewer refinement iterations and fewer degrees of freedom are required for convergence as opposed to when the procedure is not used. The mesh obtained is shown to have uniform distribution of stiffness among the nodes and elements which, as a consequence, leads to uniform error distribution. Thus the mesh obtained meets the optimality criterion of uniform error distribution.
Improving finite element results in modeling heart valve mechanics.
Earl, Emily; Mohammadi, Hadi
2018-06-01
Finite element analysis is a well-established computational tool which can be used for the analysis of soft tissue mechanics. Due to the structural complexity of the leaflet tissue of the heart valve, the currently available finite element models do not adequately represent the leaflet tissue. A method of addressing this issue is to implement computationally expensive finite element models, characterized by precise constitutive models including high-order and high-density mesh techniques. In this study, we introduce a novel numerical technique that enhances the results obtained from coarse mesh finite element models to provide accuracy comparable to that of fine mesh finite element models while maintaining a relatively low computational cost. Introduced in this study is a method by which the computational expense required to solve linear and nonlinear constitutive models, commonly used in heart valve mechanics simulations, is reduced while continuing to account for large and infinitesimal deformations. This continuum model is developed based on the least square algorithm procedure coupled with the finite difference method adhering to the assumption that the components of the strain tensor are available at all nodes of the finite element mesh model. The suggested numerical technique is easy to implement, practically efficient, and requires less computational time compared to currently available commercial finite element packages such as ANSYS and/or ABAQUS.
A multi-block adaptive solving technique based on lattice Boltzmann method
NASA Astrophysics Data System (ADS)
Zhang, Yang; Xie, Jiahua; Li, Xiaoyue; Ma, Zhenghai; Zou, Jianfeng; Zheng, Yao
2018-05-01
In this paper, a CFD parallel adaptive algorithm is self-developed by combining the multi-block Lattice Boltzmann Method (LBM) with Adaptive Mesh Refinement (AMR). The mesh refinement criterion of this algorithm is based on the density, velocity and vortices of the flow field. The refined grid boundary is obtained by extending outward half a ghost cell from the coarse grid boundary, which makes the adaptive mesh more compact and the boundary treatment more convenient. Two numerical examples of the backward step flow separation and the unsteady flow around circular cylinder demonstrate the vortex structure of the cold flow field accurately and specifically.
DNS and modeling of the interaction between turbulent premixed flames and walls
NASA Technical Reports Server (NTRS)
Poinsot, T. J.; Haworth, D. C.
1992-01-01
The interaction between turbulent premixed flames and walls is studied using a two-dimensional full Navier-Stokes solver with simple chemistry. The effects of wall distance on the local and global flame structure are investigated. Quenching distances and maximum wall heat fluxes during quenching are computed in laminar cases and are found to be comparable to experimental and analytical results. For turbulent cases, it is shown that quenching distances and maximum heat fluxes remain of the same order as for laminar flames. Based on simulation results, a 'law-of-the-wall' model is derived to describe the interaction between a turbulent premixed flame and a wall. This model is constructed to provide reasonable behavior of flame surface density near a wall under the assumption that flame-wall interaction takes place at scales smaller than the computational mesh. It can be implemented in conjunction with any of several recent flamelet models based on a modeled surface density equation, with no additional constraints on mesh size or time step.
Spatially resolved spectroscopy analysis of the XMM-Newton large program on SN1006
NASA Astrophysics Data System (ADS)
Li, Jiang-Tao; Decourchelle, Anne; Miceli, Marco; Vink, Jacco; Bocchino, Fabrizio
2016-04-01
We perform analysis of the XMM-Newton large program on SN1006 based on our newly developed methods of spatially resolved spectroscopy analysis. We extract spectra from low and high resolution meshes. The former (3596 meshes) is used to roughly decompose the thermal and non-thermal components and characterize the spatial distributions of different parameters, such as temperature, abundances of different elements, ionization age, and electron density of the thermal component, as well as photon index and cutoff frequency of the non-thermal component. On the other hand, the low resolution meshes (583 meshes) focus on the interior region dominated by the thermal emission and have enough counts to well characterize the Si lines. We fit the spectra from the low resolution meshes with different models, in order to decompose the multiple plasma components at different thermal and ionization states and compare their spatial distributions. In this poster, we will present the initial results of this project.
Cortical bone fracture analysis using XFEM - case study.
Idkaidek, Ashraf; Jasiuk, Iwona
2017-04-01
We aim to achieve an accurate simulation of human cortical bone fracture using the extended finite element method within a commercial finite element software abaqus. A two-dimensional unit cell model of cortical bone is built based on a microscopy image of the mid-diaphysis of tibia of a 70-year-old human male donor. Each phase of this model, an interstitial bone, a cement line, and an osteon, are considered linear elastic and isotropic with material properties obtained by nanoindentation, taken from literature. The effect of using fracture analysis methods (cohesive segment approach versus linear elastic fracture mechanics approach), finite element type, and boundary conditions (traction, displacement, and mixed) on cortical bone crack initiation and propagation are studied. In this study cohesive segment damage evolution for a traction separation law based on energy and displacement is used. In addition, effects of the increment size and mesh density on analysis results are investigated. We find that both cohesive segment and linear elastic fracture mechanics approaches within the extended finite element method can effectively simulate cortical bone fracture. Mesh density and simulation increment size can influence analysis results when employing either approach, and using finer mesh and/or smaller increment size does not always provide more accurate results. Both approaches provide close but not identical results, and crack propagation speed is found to be slower when using the cohesive segment approach. Also, using reduced integration elements along with the cohesive segment approach decreases crack propagation speed compared with using full integration elements. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Application of confocal laser microscopy for monitoring mesh implants in herniology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zakharov, V P; Belokonev, V I; Bratchenko, I A
2011-04-30
The state of the surface of mesh implants and their encapsulation region in herniology is investigated by laser confocal microscopy. A correlation between the probability of developing relapses and the size and density of implant microdefects is experimentally shown. The applicability limits of differential reverse scattering for monitoring the post-operation state of implant and adjacent tissues are established based on model numerical experiments. (optical technologies in biophysics and medicine)
Deeken, Corey R; Abdo, Michael S; Frisella, Margaret M; Matthews, Brent D
2011-01-01
For meshes to be used effectively for hernia repair, it is imperative that engineers and surgeons standardize the terminology and techniques related to physicomechanical evaluation of these materials. The objectives of this study were to propose standard techniques, perform physicomechanical testing, and classify materials commonly used for inguinal hernia repair. Nine meshes were evaluated: 4 polypropylene, 1 polyester, 1 polytetrafluoroethylene, and 3 partially absorbable. Physical properties were determined through image analysis, laser micrometry, and density measurements. Biomechanical properties were determined through suture retention, tear resistance, uniaxial, and ball burst testing with specimens tested in 2 different orientations. A 1-way ANOVA with Tukey's post-test or a t-test were performed, with p < 0.05. Significant differences were observed due to both mesh type and orientation. Areas of interstices ranged from 0.33 ± 0.01 mm² for ProLite (Atrium Medical Corp) and C-QUR Lite (Atrium Medical Corp) Large to 4.10 ± 0.06 mm² for ULTRAPRO (Ethicon), and filament diameters ranged from 99.00 ±8.1 μm for ProLite Ultra (Atrium Medical Corp) and C-QUR Lite Small to 338.8 ± 3.7 μm for Parietex Flat Sheet TEC (Covidien). These structural characteristics influenced biomechanical properties such as tear resistance and tensile strength. ProLite Ultra, C-QUR Lite Small, ULTRAPRO and INFINIT (WL Gore & Associates) did not resist tearing as effectively as the others. All meshes exhibited supraphysiologic burst strengths except INFINIT and ULTRAPRO. Significant differences exist between the physicomechanical properties of polypropylene, polyester, polytetrafluoroethylene, and partially absorbable mesh prostheses commonly used for inguinal hernia repair. Orientation of the mesh was also shown to be critical for the success of meshes, particularly those demonstrating anisotropy. Copyright © 2011 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology.
Fu, Tian-Ming; Hong, Guosong; Viveros, Robert D; Zhou, Tao; Lieber, Charles M
2017-11-21
Implantable electrical probes have led to advances in neuroscience, brain-machine interfaces, and treatment of neurological diseases, yet they remain limited in several key aspects. Ideally, an electrical probe should be capable of recording from large numbers of neurons across multiple local circuits and, importantly, allow stable tracking of the evolution of these neurons over the entire course of study. Silicon probes based on microfabrication can yield large-scale, high-density recording but face challenges of chronic gliosis and instability due to mechanical and structural mismatch with the brain. Ultraflexible mesh electronics, on the other hand, have demonstrated negligible chronic immune response and stable long-term brain monitoring at single-neuron level, although, to date, it has been limited to 16 channels. Here, we present a scalable scheme for highly multiplexed mesh electronics probes to bridge the gap between scalability and flexibility, where 32 to 128 channels per probe were implemented while the crucial brain-like structure and mechanics were maintained. Combining this mesh design with multisite injection, we demonstrate stable 128-channel local field potential and single-unit recordings from multiple brain regions in awake restrained mice over 4 mo. In addition, the newly integrated mesh is used to validate stable chronic recordings in freely behaving mice. This scalable scheme for mesh electronics together with demonstrated long-term stability represent important progress toward the realization of ideal implantable electrical probes allowing for mapping and tracking single-neuron level circuit changes associated with learning, aging, and neurodegenerative diseases. Copyright © 2017 the Author(s). Published by PNAS.
Hsu, Yung-Ting; Al-Hezaimi, Khalid; Galindo-Moreno, Pablo; O'Valle, Francisco; Al-Rasheed, Abdulaziz; Wang, Hom-Lay
2017-09-01
Vertical bone augmentation (VBA) remains unpredictable and challenging for most clinicians. This study aims to compare hard tissue outcomes of VBA, with and without recombinant human bone morphogenetic protein (rhBMP)-2, under space-making titanium mesh in a canine model. Eleven male beagle dogs were used in the study. Experimental ridge defects were created to form atrophic ridges. VBA was performed via guided bone regeneration using titanium mesh and allografts. In experimental hemimandibles, rhBMP-2/absorbable collagen sponge was well mixed with allografts prior to procedures, whereas a control buffer was applied within controls. Dogs were euthanized after a 4-month healing period. Clinical and radiographic examinations were performed to assess ridge dimensional changes. In addition, specimens were used for microcomputed tomography (micro-CT) assessment and histologic analysis. Membrane exposure was found on five of 11 (45.5%) rhBMP-2-treated sites, whereas it was found on nine of 11 (81.8%) non-rhBMP-2-treated sites. Within 4 months of healing, rhBMP-2-treated sites showed better radiographic bone density, greater defect fill, and significantly more bone gain in ridge height (P <0.05) than controls. Experimental hemimandibles exhibited lower rates of membrane exposure and a noteworthy, ectopic bone formation above the mesh in 72% of sites. Results from micro-CT also suggested a trend of less vertical bone gain and bone mineral density in controls (P >0.05). Under light microscope, predominant lamellar patterns were found in the specimen obtained from rhBMP-2 sites. With inherent limitations of the canine model and the concern of such a demanding surgical technique, current findings suggest that the presence of rhBMP-2 in a composite graft allows an increase of vertical gain, with formation of ectopic bone over the titanium mesh in comparison with non-rhBMP-2 sites.
NASA Astrophysics Data System (ADS)
Wang, Yang; Ma, Guowei; Ren, Feng; Li, Tuo
2017-12-01
A constrained Delaunay discretization method is developed to generate high-quality doubly adaptive meshes of highly discontinuous geological media. Complex features such as three-dimensional discrete fracture networks (DFNs), tunnels, shafts, slopes, boreholes, water curtains, and drainage systems are taken into account in the mesh generation. The constrained Delaunay triangulation method is used to create adaptive triangular elements on planar fractures. Persson's algorithm (Persson, 2005), based on an analogy between triangular elements and spring networks, is enriched to automatically discretize a planar fracture into mesh points with varying density and smooth-quality gradient. The triangulated planar fractures are treated as planar straight-line graphs (PSLGs) to construct piecewise-linear complex (PLC) for constrained Delaunay tetrahedralization. This guarantees the doubly adaptive characteristic of the resulted mesh: the mesh is adaptive not only along fractures but also in space. The quality of elements is compared with the results from an existing method. It is verified that the present method can generate smoother elements and a better distribution of element aspect ratios. Two numerical simulations are implemented to demonstrate that the present method can be applied to various simulations of complex geological media that contain a large number of discontinuities.
Optimal design of permeable fiber network structures for fog harvesting.
Park, Kyoo-Chul; Chhatre, Shreerang S; Srinivasan, Siddarth; Cohen, Robert E; McKinley, Gareth H
2013-10-29
Fog represents a large untapped source of potable water, especially in arid climates. Numerous plants and animals use textural and chemical features on their surfaces to harvest this precious resource. In this work, we investigate the influence of the surface wettability characteristics, length scale, and weave density on the fog-harvesting capability of woven meshes. We develop a combined hydrodynamic and surface wettability model to predict the overall fog-collection efficiency of the meshes and cast the findings in the form of a design chart. Two limiting surface wettability constraints govern the re-entrainment of collected droplets and clogging of mesh openings. Appropriate tuning of the wetting characteristics of the surfaces, reducing the wire radii, and optimizing the wire spacing all lead to more efficient fog collection. We use a family of coated meshes with a directed stream of fog droplets to simulate a natural foggy environment and demonstrate a five-fold enhancement in the fog-collecting efficiency of a conventional polyolefin mesh. The design rules developed in this work can be applied to select a mesh surface with optimal topography and wetting characteristics to harvest enhanced water fluxes over a wide range of natural convected fog environments.
Testing hydrodynamics schemes in galaxy disc simulations
NASA Astrophysics Data System (ADS)
Few, C. G.; Dobbs, C.; Pettitt, A.; Konstandin, L.
2016-08-01
We examine how three fundamentally different numerical hydrodynamics codes follow the evolution of an isothermal galactic disc with an external spiral potential. We compare an adaptive mesh refinement code (RAMSES), a smoothed particle hydrodynamics code (SPHNG), and a volume-discretized mesh-less code (GIZMO). Using standard refinement criteria, we find that RAMSES produces a disc that is less vertically concentrated and does not reach such high densities as the SPHNG or GIZMO runs. The gas surface density in the spiral arms increases at a lower rate for the RAMSES simulations compared to the other codes. There is also a greater degree of substructure in the SPHNG and GIZMO runs and secondary spiral arms are more pronounced. By resolving the Jeans length with a greater number of grid cells, we achieve more similar results to the Lagrangian codes used in this study. Other alterations to the refinement scheme (adding extra levels of refinement and refining based on local density gradients) are less successful in reducing the disparity between RAMSES and SPHNG/GIZMO. Although more similar, SPHNG displays different density distributions and vertical mass profiles to all modes of GIZMO (including the smoothed particle hydrodynamics version). This suggests differences also arise which are not intrinsic to the particular method but rather due to its implementation. The discrepancies between codes (in particular, the densities reached in the spiral arms) could potentially result in differences in the locations and time-scales for gravitational collapse, and therefore impact star formation activity in more complex galaxy disc simulations.
NASA Astrophysics Data System (ADS)
Gaytan, S. M.; Murr, L. E.; Martinez, E.; Martinez, J. L.; Machado, B. I.; Ramirez, D. A.; Medina, F.; Collins, S.; Wicker, R. B.
2010-12-01
The microstructures and mechanical behavior of simple, as-fabricated, solid geometries (with a density of 8.4 g/cm3), as-fabricated and fabricated and annealed femoral (knee) prototypes, and reticulated mesh components (with a density of 1.5 g/cm3) all produced by additive manufacturing (AM) using electron beam melting (EBM) of Co-26Cr-6Mo-0.2C powder are examined and compared in this study. Microstructures and microstructural issues are examined by optical metallography (OM), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectrometry (EDS), and X-ray diffraction (XRD), while mechanical properties included selective specimen tensile testing and Vickers microindentation hardness (HV) and Rockwell C-scale hardness (HRC) measurements. Orthogonal (X-Y) melt scanning of the electron beam during AM produced unique, orthogonal and related Cr23C6 carbide (precipitate) arrays (a controlled microstructural architecture) with dimensions of 2 μm in the build plane perpendicular to the build direction, while connected carbide columns were formed in the vertical plane, parallel to the build direction, with microindentation hardnesses ranging from 4.4 to 5.9 GPa, corresponding to a yield stress and ultimate tensile strength (UTS) of 0.51 and 1.45 GPa with elongations ranging from 1.9 to 5.3 pct. Annealing produced an equiaxed fcc grain structure with some grain boundary carbides, frequent annealing twins, and often a high density of intrinsic {111} stacking faults within the grains. The reticulated mesh strut microstructure consisted of dense carbide arrays producing an average microindentation hardness of 6.2 GPa or roughly 25 pct higher than the fully dense components.
Error driven remeshing strategy in an elastic-plastic shakedown problem
NASA Astrophysics Data System (ADS)
Pazdanowski, Michał J.
2018-01-01
A shakedown based approach has been for many years successfully used to calculate the distributions of residual stresses in bodies made of elastic-plastic materials and subjected to cyclic loads exceeding their bearing capacity. The calculations performed indicated the existence of areas characterized by extremely high gradients and rapid changes of sign over small areas in the stress field sought. In order to account for these changes in sign, relatively dense nodal meshes had to be used during calculations in disproportionately large parts of considered bodies, resulting in unnecessary expenditure of computer resources. Therefore the effort was undertaken to limit the areas of high mesh densities and drive the mesh regeneration algorithm by selected error indicators.
NASA Astrophysics Data System (ADS)
Aziznia, Amin; Oloman, Colin W.; Gyenge, Előd L.
2014-11-01
The Swiss-roll single-cell mixed reactant (SR-MRFC) borohydride - oxygen fuel cell equipped with Pt/carbon cloth 3D anode and either MnO2 or Ag gas-diffusion cathodes is investigated by a combination of experimental studies and preliminary mathematical modeling of the polarization curve. We investigate the effects of four variables: cathode side metallic mesh fluid distributor, separator type (Nafion 112® vs. Viledon®), cathode catalyst (MnO2 vs. Ag), and the hydrophilic pore volume fraction of the gas-diffusion cathode. Using a two-phase feed of alkaline borohydride solution (1 M NaBH4 - 2 M NaOH) and O2 gas in an SR-MRFC equipped with Pt/C 3D anode, MnO2 gas diffusion cathode, Viledon® porous diaphragm, expanded mesh cathode-side fluid distributor, the maximum superficial power density is 2230 W m-2 at 323 K and 105 kPa(abs). The latter superficial power density is almost 3.5 times higher than our previously reported superficial power density for the same catalyst combinations. Furthermore, with a Pt anode and Ag cathode catalyst combination, a superficial power density of 2500 W m-2 is achieved with superior performance durability compared to the MnO2 cathode. The fuel cell results are substantiated by impedance spectroscopy analysis and preliminary mathematical model predictions based on mixed potential theory.
An Immersed Boundary-Lattice Boltzmann Method for Simulating Particulate Flows
NASA Astrophysics Data System (ADS)
Zhang, Baili; Cheng, Ming; Lou, Jing
2013-11-01
A two-dimensional momentum exchange-based immersed boundary-lattice Boltzmann method developed by X.D. Niu et al. (2006) has been extended in three-dimensions for solving fluid-particles interaction problems. This method combines the most desirable features of the lattice Boltzmann method and the immersed boundary method by using a regular Eulerian mesh for the flow domain and a Lagrangian mesh for the moving particles in the flow field. The non-slip boundary conditions for the fluid and the particles are enforced by adding a force density term into the lattice Boltzmann equation, and the forcing term is simply calculated by the momentum exchange of the boundary particle density distribution functions, which are interpolated by the Lagrangian polynomials from the underlying Eulerian mesh. This method preserves the advantages of lattice Boltzmann method in tracking a group of particles and, at the same time, provides an alternative approach to treat solid-fluid boundary conditions. Numerical validations show that the present method is very accurate and efficient. The present method will be further developed to simulate more complex problems with particle deformation, particle-bubble and particle-droplet interactions.
Estimating neuromuscular stimulation within the human torso with Taser stimulus.
Sun, Hongyu; Webster, John G
2007-11-07
Designers of electromuscular incapacitation devices need to know efficacy. Which areas of nerve and muscle are stimulated and are these areas adequate to cause incapacitation? This paper focuses on efficacy, which used a torso-sized finite element model with a mesh of about 5 mm. To estimate the neuromuscular regions stimulated by the Taser X26, calculations of electric current density and field strength values with 1 A inserted into the torso using the Utah 3D mesh were made. Field-times-duration values for given Taser stimulation were calculated. Then the region where the motor nerve was stimulated by the Taser was estimated by using a field-times-duration threshold from Reilly (1998 'Applied Bioelectricity: From Electrical Stimulation to Electropathology ' (New York: Springer)). Neuromuscular stimulation occurred up to about 19 cm away from the darts and included the spinal cord. The current density at the heart for dart separation less than 10 cm was smaller than for larger dart separation. Users of finite element computer models will find information for torso models and their creation, meshing and operation.
Estimating neuromuscular stimulation within the human torso with Taser® stimulus
NASA Astrophysics Data System (ADS)
Sun, Hongyu; Webster, John G.
2007-11-01
Designers of electromuscular incapacitation devices need to know efficacy. Which areas of nerve and muscle are stimulated and are these areas adequate to cause incapacitation? This paper focuses on efficacy, which used a torso-sized finite element model with a mesh of about 5 mm. To estimate the neuromuscular regions stimulated by the Taser® X26, calculations of electric current density and field strength values with 1 A inserted into the torso using the Utah 3D mesh were made. Field-times-duration values for given Taser stimulation were calculated. Then the region where the motor nerve was stimulated by the Taser was estimated by using a field-times-duration threshold from Reilly (1998 Applied Bioelectricity: From Electrical Stimulation to Electropathology (New York: Springer)). Neuromuscular stimulation occurred up to about 19 cm away from the darts and included the spinal cord. The current density at the heart for dart separation less than 10 cm was smaller than for larger dart separation. Users of finite element computer models will find information for torso models and their creation, meshing and operation.
The Effects of Dissipation and Coarse Grid Resolution for Multigrid in Flow Problems
NASA Technical Reports Server (NTRS)
Eliasson, Peter; Engquist, Bjoern
1996-01-01
The objective of this paper is to investigate the effects of the numerical dissipation and the resolution of the solution on coarser grids for multigrid with the Euler equation approximations. The convergence is accomplished by multi-stage explicit time-stepping to steady state accelerated by FAS multigrid. A theoretical investigation is carried out for linear hyperbolic equations in one and two dimensions. The spectra reveals that for stability and hence robustness of spatial discretizations with a small amount of numerical dissipation the grid transfer operators have to be accurate enough and the smoother of low temporal accuracy. Numerical results give grid independent convergence in one dimension. For two-dimensional problems with a small amount of numerical dissipation, however, only a few grid levels contribute to an increased speed of convergence. This is explained by the small numerical dissipation leading to dispersion. Increasing the mesh density and hence making the problem over resolved increases the number of mesh levels contributing to an increased speed of convergence. If the steady state equations are elliptic, all grid levels contribute to the convergence regardless of the mesh density.
Toward Effective Shell Modeling of Wrinkled Thin-Film Membranes Exhibiting Stress Concentrations
NASA Technical Reports Server (NTRS)
Tessler, Alexander; Sleight, David W.
2004-01-01
Geometrically nonlinear shell finite element analysis has recently been applied to solar-sail membrane problems in order to model the out-of-plane deformations due to structural wrinkling. Whereas certain problems lend themselves to achieving converged nonlinear solutions that compare favorably with experimental observations, solutions to tensioned membranes exhibiting high stress concentrations have been difficult to obtain even with the best nonlinear finite element codes and advanced shell element technology. In this paper, two numerical studies are presented that pave the way to improving the modeling of this class of nonlinear problems. The studies address the issues of mesh refinement and stress-concentration alleviation, and the effects of these modeling strategies on the ability to attain converged nonlinear deformations due to wrinkling. The numerical studies demonstrate that excessive mesh refinement in the regions of stress concentration may be disadvantageous to achieving wrinkled equilibrium states, causing the nonlinear solution to lock in the membrane response mode, while totally discarding the very low-energy bending response that is necessary to cause wrinkling deformation patterns. An element-level, strain-energy density criterion is suggested for facilitating automated, adaptive mesh refinements specifically aimed at the modeling of thin-film membranes undergoing wrinkling deformations.
Louri, A; Furlonge, S; Neocleous, C
1996-12-10
A prototype of a novel topology for scaleable optical interconnection networks called the optical multi-mesh hypercube (OMMH) is experimentally demonstrated to as high as a 150-Mbit/s data rate (2(7) - 1 nonreturn-to-zero pseudo-random data pattern) at a bit error rate of 10(-13)/link by the use of commercially available devices. OMMH is a scaleable network [Appl. Opt. 33, 7558 (1994); J. Lightwave Technol. 12, 704 (1994)] architecture that combines the positive features of the hypercube (small diameter, connectivity, symmetry, simple routing, and fault tolerance) and the mesh (constant node degree and size scaleability). The optical implementation method is divided into two levels: high-density local connections for the hypercube modules, and high-bit-rate, low-density, long connections for the mesh links connecting the hypercube modules. Free-space imaging systems utilizing vertical-cavity surface-emitting laser (VCSEL) arrays, lenslet arrays, space-invariant holographic techniques, and photodiode arrays are demonstrated for the local connections. Optobus fiber interconnects from Motorola are used for the long-distance connections. The OMMH was optimized to operate at the data rate of Motorola's Optobus (10-bit-wide, VCSEL-based bidirectional data interconnects at 150 Mbits/s). Difficulties encountered included the varying fan-out efficiencies of the different orders of the hologram, misalignment sensitivity of the free-space links, low power (1 mW) of the individual VCSEL's, and noise.
Spatial Convergence of Three Dimensional Turbulent Flows
NASA Technical Reports Server (NTRS)
Park, Michael A.; Anderson, W. Kyle
2016-01-01
Finite-volume and finite-element schemes, both implemented within the FUN3D flow solver, are evaluated for several test cases described on the Turbulence-Modeling Resource (TMR) web site. The cases include subsonic flow over a hemisphere cylinder, subsonic flow over a swept bump configuration, and supersonic flow in a square duct. The finite- volume and finite-element schemes are both used to obtain solutions for the first two cases, whereas only the finite-volume scheme is used for the supersonic duct. For the hemisphere cylinder, finite-element solutions obtained on tetrahedral meshes are compared with finite- volume solutions on mixed-element meshes. For the swept bump, finite-volume solutions have been obtained for both hexahedral and tetrahedral meshes and are compared with finite-element solutions obtained on tetrahedral meshes. For the hemisphere cylinder and the swept bump, solutions are obtained on a series of meshes with varying grid density and comparisons are made between drag coefficients, pressure distributions, velocity profiles, and profiles of the turbulence working variable. The square duct shows small variation due to element type or the spatial accuracy of turbulence model convection. It is demonstrated that the finite-element scheme on tetrahedral meshes yields similar accuracy as the finite- volume scheme on mixed-element and hexahedral grids, and demonstrates less sensitivity to the mesh topology (biased tetrahedral grids) than the finite-volume scheme.
NASA Astrophysics Data System (ADS)
Sun, Peng; Yi, Huan; Peng, Tianquan; Jing, Yuting; Wang, Ruijing; Wang, Huanwen; Wang, Xuefeng
2017-02-01
Manganese dioxide is a promising electrode material for electrochemical supercapacitors, but its poor electronic conductivity (10-5∼10-6 S cm-1) limits the fast charge/discharge rate for practical applications. In the present work, we use the chemical vapor deposition (CVD) method to grow highly conductive carbon nanotube (CNT) networks on flexible Ni mesh, on which MnO2 nanoflake layers are deposited by a simple solution method, forming a hierarchical core-shell structure. Under the optimized mass loading, the as-fabricated MnO2 nanoflake@CNTs/Ni mesh electrode exhibits a high specific capacitance of 1072 F g-1 at 1 A g-1 in three-electrode configuration. Due to advantageous features of these core-shell electrodes (e.g., high conductivity, direct current path, structure stability), the as-assembled symmetric supercapacitor (SSC) based on MnO2@CNTs/Ni mesh has a wide working voltage (2.0 V) in 1 M Na2SO4 aqueous electrolyte. Finally an impressive energy density of 94.4 Wh kg-1 at 1000 W kg-1 and a high power density of 30.2 kW kg-1 at 33.6 Wh kg-1 have been achieved for the as-assembled SSC, which exhibits a great potential as a low-cost, high energy density and attractive wearable energy storage device.
Lateral Membrane Diffusion Modulated by a Minimal Actin Cortex
Heinemann, Fabian; Vogel, Sven K.; Schwille, Petra
2013-01-01
Diffusion of lipids and proteins within the cell membrane is essential for numerous membrane-dependent processes including signaling and molecular interactions. It is assumed that the membrane-associated cytoskeleton modulates lateral diffusion. Here, we use a minimal actin cortex to directly study proposed effects of an actin meshwork on the diffusion in a well-defined system. The lateral diffusion of a lipid and a protein probe at varying densities of membrane-bound actin was characterized by fluorescence correlation spectroscopy (FCS). A clear correlation of actin density and reduction in mobility was observed for both the lipid and the protein probe. At high actin densities, the effect on the protein probe was ∼3.5-fold stronger compared to the lipid. Moreover, addition of myosin filaments, which contract the actin mesh, allowed switching between fast and slow diffusion in the minimal system. Spot variation FCS was in accordance with a model of fast microscopic diffusion and slower macroscopic diffusion. Complementing Monte Carlo simulations support the analysis of the experimental FCS data. Our results suggest a stronger interaction of the actin mesh with the larger protein probe compared to the lipid. This might point toward a mechanism where cortical actin controls membrane diffusion in a strong size-dependent manner. PMID:23561523
Burner liner thermal-structural load modeling
NASA Technical Reports Server (NTRS)
Maffeo, R.
1986-01-01
The software package Transfer Analysis Code to Interface Thermal/Structural Problems (TRANCITS) was developed. The TRANCITS code is used to interface temperature data between thermal and structural analytical models. The use of this transfer module allows the heat transfer analyst to select the thermal mesh density and thermal analysis code best suited to solve the thermal problem and gives the same freedoms to the stress analyst, without the efficiency penalties associated with common meshes and the accuracy penalties associated with the manual transfer of thermal data.
Arregui-Dalmases, Carlos; Del Pozo, Eduardo; Duprey, Sonia; Lopez-Valdes, Francisco J; Lau, Anthony; Subit, Damien; Kent, Richard
2010-06-01
The objectives of this study were to examine the axial response of the clavicle under quasistatic compressions replicating the body boundary conditions and to quantify the sensitivity of finite element-predicted fracture in the clavicle to several parameters. Clavicles were harvested from 14 donors (age range 14-56 years). Quasistatic axial compression tests were performed using a custom rig designed to replicate in situ boundary conditions. Prior to testing, high-resolution computed tomography (CT) scans were taken of each clavicle. From those images, finite element models were constructed. Factors varied parametrically included the density used to threshold cortical bone in the CT scans, the presence of trabecular bone, the mesh density, Young's modulus, the maximum stress, and the element type (shell vs. solid, triangular vs. quadrilateral surface elements). The experiments revealed significant variability in the peak force (2.41 +/- 0.72 kN) and displacement to peak force (4.9 +/- 1.1 mm), with age (p < .05) and with some geometrical traits of the specimens. In the finite element models, the failure force and location were moderately dependent upon the Young's modulus. The fracture force was highly sensitive to the yield stress (80-110 MPa). Neither fracture location nor force was strongly dependent on mesh density as long as the element size was less than 5 x 5 mm(2). Both the fracture location and force were strongly dependent upon the threshold density used to define the thickness of the cortical shell.
Manual for automatic generation of finite element models of spiral bevel gears in mesh
NASA Technical Reports Server (NTRS)
Bibel, G. D.; Reddy, S.; Kumar, A.
1994-01-01
The goal of this research is to develop computer programs that generate finite element models suitable for doing 3D contact analysis of faced milled spiral bevel gears in mesh. A pinion tooth and a gear tooth are created and put in mesh. There are two programs: Points.f and Pat.f to perform the analysis. Points.f is based on the equation of meshing for spiral bevel gears. It uses machine tool settings to solve for an N x M mesh of points on the four surfaces, pinion concave and convex, and gear concave and convex. Points.f creates the file POINTS.OUT, an ASCI file containing N x M points for each surface. (N is the number of node points along the length of the tooth, and M is nodes along the height.) Pat.f reads POINTS.OUT and creates the file tl.out. Tl.out is a series of PATRAN input commands. In addition to the mesh density on the tooth face, additional user specified variables are the number of finite elements through the thickness, and the number of finite elements along the tooth full fillet. A full fillet is assumed to exist for both the pinion and gear.
SANTA BARBARA CLUSTER COMPARISON TEST WITH DISPH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saitoh, Takayuki R.; Makino, Junichiro, E-mail: saitoh@elsi.jp
2016-06-01
The Santa Barbara cluster comparison project revealed that there is a systematic difference between entropy profiles of clusters of galaxies obtained by Eulerian mesh and Lagrangian smoothed particle hydrodynamics (SPH) codes: mesh codes gave a core with a constant entropy, whereas SPH codes did not. One possible reason for this difference is that mesh codes are not Galilean invariant. Another possible reason is the problem of the SPH method, which might give too much “protection” to cold clumps because of the unphysical surface tension induced at contact discontinuities. In this paper, we apply the density-independent formulation of SPH (DISPH), whichmore » can handle contact discontinuities accurately, to simulations of a cluster of galaxies and compare the results with those with the standard SPH. We obtained the entropy core when we adopt DISPH. The size of the core is, however, significantly smaller than those obtained with mesh simulations and is comparable to those obtained with quasi-Lagrangian schemes such as “moving mesh” and “mesh free” schemes. We conclude that both the standard SPH without artificial conductivity and Eulerian mesh codes have serious problems even with such an idealized simulation, while DISPH, SPH with artificial conductivity, and quasi-Lagrangian schemes have sufficient capability to deal with it.« less
Automated hexahedral mesh generation from biomedical image data: applications in limb prosthetics.
Zachariah, S G; Sanders, J E; Turkiyyah, G M
1996-06-01
A general method to generate hexahedral meshes for finite element analysis of residual limbs and similar biomedical geometries is presented. The method utilizes skeleton-based subdivision of cross-sectional domains to produce simple subdomains in which structured meshes are easily generated. Application to a below-knee residual limb and external prosthetic socket is described. The residual limb was modeled as consisting of bones, soft tissue, and skin. The prosthetic socket model comprised a socket wall with an inner liner. The geometries of these structures were defined using axial cross-sectional contour data from X-ray computed tomography, optical scanning, and mechanical surface digitization. A tubular surface representation, using B-splines to define the directrix and generator, is shown to be convenient for definition of the structure geometries. Conversion of cross-sectional data to the compact tubular surface representation is direct, and the analytical representation simplifies geometric querying and numerical optimization within the mesh generation algorithms. The element meshes remain geometrically accurate since boundary nodes are constrained to lie on the tubular surfaces. Several element meshes of increasing mesh density were generated for two residual limbs and prosthetic sockets. Convergence testing demonstrated that approximately 19 elements are required along a circumference of the residual limb surface for a simple linear elastic model. A model with the fibula absent compared with the same geometry with the fibula present showed differences suggesting higher distal stresses in the absence of the fibula. Automated hexahedral mesh generation algorithms for sliced data represent an advancement in prosthetic stress analysis since they allow rapid modeling of any given residual limb and optimization of mesh parameters.
NASA Astrophysics Data System (ADS)
Wang, Andrew; Gyenge, Előd L.
2015-05-01
The electrochemical oxidation of BH4- in a molten NaOH-KOH eutectic mixture (0.515:0.485 mole fractions), is investigated for the first time by cyclic voltammetry and electrochemical impedance spectroscopy. Anodically oxidized Ni is electrocatalytically more active than Pt for BH4- oxidation in the molten alkali electrolyte as shown by the more than three times higher exchange current density (i.e. 15.8 mA cm-2 vs. 4.6 mA cm-2 at 185 °C). Next the proof-of-concept for a novel BH4-/IO4- molten alkali electrolyte battery is presented. Using oxidized Ni mesh anode and Pt mesh cathode a maximum power density of 63 mW cm-2 is achieved at 185 °C.
Numerical Simulations of Spacecraft Charging: Selected Applications
NASA Astrophysics Data System (ADS)
Moulton, J. D.; Delzanno, G. L.; Meierbachtol, C.; Svyatskiy, D.; Vernon, L.; Borovsky, J.; Thomsen, M. F.
2016-12-01
The electrical charging of spacecraft due to bombarding charged particles affects their performance and operation. We study this charging using CPIC, a particle-in-cell code specifically designed for studying plasma-material interactions. CPIC is based on multi-block curvilinear meshes, resulting in near-optimal computational performance while maintaining geometric accuracy. It is interfaced to a mesh generator that creates a computational mesh conforming to complex objects like a spacecraft. Relevant plasma parameters can be imported from the SHIELDS framework (currently under development at LANL), which simulates geomagnetic storms and substorms in the Earth's magnetosphere. Selected physics results will be presented, together with an overview of the code. The physics results include spacecraft-charging simulations with geometry representative of the Van Allen Probes spacecraft, focusing on the conditions that can lead to significant spacecraft charging events. Second, results from a recent study that investigates the conditions for which a high-power (>keV) electron beam could be emitted from a magnetospheric spacecraft will be presented. The latter study proposes a spacecraft-charging mitigation strategy based on the plasma contactor technology that might allow beam experiments to operate in the low-density magnetosphere. High-power electron beams could be used for instance to establish magnetic-field-line connectivity between ionosphere and magnetosphere and help solving long-standing questions in ionospheric/magnetospheric physics.
Redwing: A MOOSE application for coupling MPACT and BISON
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frederick N. Gleicher; Michael Rose; Tom Downar
Fuel performance and whole core neutron transport programs are often used to analyze fuel behavior as it is depleted in a reactor. For fuel performance programs, internal models provide the local intra-pin power density, fast neutron flux, burnup, and fission rate density, which are needed for a fuel performance analysis. The fuel performance internal models have a number of limitations. These include effects on the intra-pin power distribution by nearby assembly elements, such as water channels and control rods, and the further limitation of applicability to a specified fuel type such as low enriched UO2. In addition, whole core neutronmore » transport codes need an accurate intra-pin temperature distribution in order to calculate neutron cross sections. Fuel performance simulations are able to model the intra-pin fuel displacement as the fuel expands and densifies. These displacements must be accurately modeled in order to capture the eventual mechanical contact of the fuel and the clad; the correct radial gap width is needed for an accurate calculation of the temperature distribution of the fuel rod. Redwing is a MOOSE-based application that enables coupling between MPACT and BISON for transport and fuel performance coupling. MPACT is a 3D neutron transport and reactor core simulator based on the method of characteristics (MOC). The development of MPACT began at the University of Michigan (UM) and now is under the joint development of ORNL and UM as part of the DOE CASL Simulation Hub. MPACT is able to model the effects of local assembly elements and is able calculate intra-pin quantities such as the local power density on a volumetric mesh for any fuel type. BISON is a fuel performance application of Multi-physics Object Oriented Simulation Environment (MOOSE), which is under development at Idaho National Laboratory. BISON is able to solve the nonlinearly coupled mechanical deformation and heat transfer finite element equations that model a fuel element as it is depleted in a nuclear reactor. Redwing couples BISON and MPACT in a single application. Redwing maps and transfers the individual intra-pin quantities such as fission rate density, power density, and fast neutron flux from the MPACT volumetric mesh to the individual BISON finite element meshes. For a two-way coupling Redwing maps and transfers the individual pin temperature field and axially dependent coolant densities from the BISON mesh to the MPACT volumetric mesh. Details of the mapping are given. Redwing advances the simulation with the MPACT solution for each depletion time step and then advances the multiple BISON simulations for fuel performance calculations. Sub-cycle advancement can be applied to the individual BISON simulations and allows multiple time steps to be applied to the fuel performance simulations. Currently, only loose coupling where data from a previous time step is applied to the current time step is performed.« less
Kaminsky, Jan; Rodt, Thomas; Gharabaghi, Alireza; Forster, Jan; Brand, Gerd; Samii, Madjid
2005-06-01
The FE-modeling of complex anatomical structures is not solved satisfyingly so far. Voxel-based as opposed to contour-based algorithms allow an automated mesh generation based on the image data. Nonetheless their geometric precision is limited. We developed an automated mesh-generator that combines the advantages of voxel-based generation with improved representation of the geometry by displacement of nodes on the object-surface. Models of an artificial 3D-pipe-section and a skullbase were generated with different mesh-densities using the newly developed geometric, unsmoothed and smoothed voxel generators. Compared to the analytic calculation of the 3D-pipe-section model the normalized RMS error of the surface stress was 0.173-0.647 for the unsmoothed voxel models, 0.111-0.616 for the smoothed voxel models with small volume error and 0.126-0.273 for the geometric models. The highest element-energy error as a criterion for the mesh quality was 2.61x10(-2) N mm, 2.46x10(-2) N mm and 1.81x10(-2) N mm for unsmoothed, smoothed and geometric voxel models, respectively. The geometric model of the 3D-skullbase resulted in the lowest element-energy error and volume error. This algorithm also allowed the best representation of anatomical details. The presented geometric mesh-generator is universally applicable and allows an automated and accurate modeling by combining the advantages of the voxel-technique and of improved surface-modeling.
A third-order moving mesh cell-centered scheme for one-dimensional elastic-plastic flows
NASA Astrophysics Data System (ADS)
Cheng, Jun-Bo; Huang, Weizhang; Jiang, Song; Tian, Baolin
2017-11-01
A third-order moving mesh cell-centered scheme without the remapping of physical variables is developed for the numerical solution of one-dimensional elastic-plastic flows with the Mie-Grüneisen equation of state, the Wilkins constitutive model, and the von Mises yielding criterion. The scheme combines the Lagrangian method with the MMPDE moving mesh method and adaptively moves the mesh to better resolve shock and other types of waves while preventing the mesh from crossing and tangling. It can be viewed as a direct arbitrarily Lagrangian-Eulerian method but can also be degenerated to a purely Lagrangian scheme. It treats the relative velocity of the fluid with respect to the mesh as constant in time between time steps, which allows high-order approximation of free boundaries. A time dependent scaling is used in the monitor function to avoid possible sudden movement of the mesh points due to the creation or diminishing of shock and rarefaction waves or the steepening of those waves. A two-rarefaction Riemann solver with elastic waves is employed to compute the Godunov values of the density, pressure, velocity, and deviatoric stress at cell interfaces. Numerical results are presented for three examples. The third-order convergence of the scheme and its ability to concentrate mesh points around shock and elastic rarefaction waves are demonstrated. The obtained numerical results are in good agreement with those in literature. The new scheme is also shown to be more accurate in resolving shock and rarefaction waves than an existing third-order cell-centered Lagrangian scheme.
Liao, Ke; Zhu, Min; Ding, Lei
2013-08-01
The present study investigated the use of transform sparseness of cortical current density on human brain surface to improve electroencephalography/magnetoencephalography (EEG/MEG) inverse solutions. Transform sparseness was assessed by evaluating compressibility of cortical current densities in transform domains. To do that, a structure compression method from computer graphics was first adopted to compress cortical surface structure, either regular or irregular, into hierarchical multi-resolution meshes. Then, a new face-based wavelet method based on generated multi-resolution meshes was proposed to compress current density functions defined on cortical surfaces. Twelve cortical surface models were built by three EEG/MEG softwares and their structural compressibility was evaluated and compared by the proposed method. Monte Carlo simulations were implemented to evaluate the performance of the proposed wavelet method in compressing various cortical current density distributions as compared to other two available vertex-based wavelet methods. The present results indicate that the face-based wavelet method can achieve higher transform sparseness than vertex-based wavelet methods. Furthermore, basis functions from the face-based wavelet method have lower coherence against typical EEG and MEG measurement systems than vertex-based wavelet methods. Both high transform sparseness and low coherent measurements suggest that the proposed face-based wavelet method can improve the performance of L1-norm regularized EEG/MEG inverse solutions, which was further demonstrated in simulations and experimental setups using MEG data. Thus, this new transform on complicated cortical structure is promising to significantly advance EEG/MEG inverse source imaging technologies. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Finite-element 3D simulation tools for high-current relativistic electron beams
NASA Astrophysics Data System (ADS)
Humphries, Stanley; Ekdahl, Carl
2002-08-01
The DARHT second-axis injector is a challenge for computer simulations. Electrons are subject to strong beam-generated forces. The fields are fully three-dimensional and accurate calculations at surfaces are critical. We describe methods applied in OmniTrak, a 3D finite-element code suite that can address DARHT and the full range of charged-particle devices. The system handles mesh generation, electrostatics, magnetostatics and self-consistent particle orbits. The MetaMesh program generates meshes of conformal hexahedrons to fit any user geometry. The code has the unique ability to create structured conformal meshes with cubic logic. Organized meshes offer advantages in speed and memory utilization in the orbit and field solutions. OmniTrak is a versatile charged-particle code that handles 3D electric and magnetic field solutions on independent meshes. The program can update both 3D field solutions from the calculated beam space-charge and current-density. We shall describe numerical methods for orbit tracking on a hexahedron mesh. Topics include: 1) identification of elements along the particle trajectory, 2) fast searches and adaptive field calculations, 3) interpolation methods to terminate orbits on material surfaces, 4) automatic particle generation on multiple emission surfaces to model space-charge-limited emission and field emission, 5) flexible Child law algorithms, 6) implementation of the dual potential model for 3D magnetostatics, and 7) assignment of charge and current from model particle orbits for self-consistent fields.
Calculation of Water Entry Problem for Free-falling Bodies Using a Developed Cartesian Cut Cell Mesh
NASA Astrophysics Data System (ADS)
Wenhua, Wang; Yanying, Wang
2010-05-01
This paper describes the development of free surface capturing method on Cartesian cut cell mesh to water entry problem for free-falling bodies with body-fluid interaction. The incompressible Euler equations for a variable density fluid system are presented as governing equations and the free surface is treated as a contact discontinuity by using free surface capturing method. In order to be convenient for dealing with the problem with moving body boundary, the Cartesian cut cell technique is adopted for generating the boundary-fitted mesh around body edge by cutting solid regions out of a background Cartesian mesh. Based on this mesh system, governing equations are discretized by finite volume method, and at each cell edge inviscid flux is evaluated by means of Roe's approximate Riemann solver. Furthermore, for unsteady calculation in time domain, a time accurate solution is achieved by a dual time-stepping technique with artificial compressibility method. For the body-fluid interaction, the projection method of momentum equations and exact Riemann solution are applied in the calculation of fluid pressure on the solid boundary. Finally, the method is validated by test case of water entry for free-falling bodies.
Constrained sheath optics for high thrust density, low specific impulse ion thrusters
NASA Technical Reports Server (NTRS)
Wilbur, Paul J.; Han, Jian-Zhang
1987-01-01
The results of an experimental study showing that a contoured, fine wire mesh attached to the screen grid can be used to control the divergence characteristics of ion beamlets produced at low net-to-total accelerating voltage ratios are presented. The influence of free and constrained-sheath optics systems on beamlet divergence characteristics are found to be similar in the operating regime investigated, but it was found that constrained-sheath optics systems can be operated at higher perveance levels than free-sheath ones. The concept of a fine wire interference probe that can be used to study ion beamlet focusing behavior is introduced. This probe is used to demonstrate beamlet focusing to a diameter about one hundreth of the screen grid extraction aperture diameter. Additional testing is suggested to define an optimally contoured mesh that could yield well focused beamlets at net-to-total accelerating voltage ratios below about 0.1.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hughes, Justin Matthew
These are the slides for a graduate presentation at Mississippi State University. It covers the following: the BRL Shaped-Charge Geometry in PAGOSA, mesh refinement study, surrogate modeling using a radial basis function network (RBFN), ruling out parameters using sensitivity analysis (equation of state study), uncertainty quantification (UQ) methodology, and sensitivity analysis (SA) methodology. In summary, a mesh convergence study was used to ensure that solutions were numerically stable by comparing PDV data between simulations. A Design of Experiments (DOE) method was used to reduce the simulation space to study the effects of the Jones-Wilkins-Lee (JWL) Parameters for the Composition Bmore » main charge. Uncertainty was quantified by computing the 95% data range about the median of simulation output using a brute force Monte Carlo (MC) random sampling method. Parameter sensitivities were quantified using the Fourier Amplitude Sensitivity Test (FAST) spectral analysis method where it was determined that detonation velocity, initial density, C1, and B1 controlled jet tip velocity.« less
Merali, N.; Almeida, R.A.R.; Hussain, A.
2015-01-01
Introduction We present a case on conservative management of salvaging the mesh in an immunocompromised morbidly obese patient, who developed a synergistic gangrene infection following a primary open mesh repair of an incisional hernia. Presentation of case Our patient presented with a surgical wound infection, comorbidities were Chronic Lymphoblastic Leukemia (CLL), Body Mass Index (BMI) of 50, hypertension and diet controlled type-2 diabetes. In surgery, wide necrotic wound debridement, early and repetitive wound drainages with the use of a large pore polypropylene mesh and a detailed surgical follow up was required. High dose intravenous broad-spectrum antibiotic treatment and Negative Pressure Wound Therapy (NPWT) was administrated in combination with adopting a multidisciplinary approach was key to our success. Discussion Stoppa Re et al. complied a series of 360 ventral hernia mesh repairs reporting an infection rate of 12% that were managed conservatively. However, our selective case is unique within current literature, being the first to illustrate mesh salvage in a morbid obese patient with CLL. Recent modifications in mesh morphology, such as lower density, wide pores, and lighter weight has led to considerable improvements regarding infection avoidance. Conclusion This case has demonstrated how a planned multidisciplinary action can produce prosperous results in a severely obese immunocompromised patient with an SSI, following an incisional hernia repair. PMID:26322822
Merali, N; Almeida, R A R; Hussain, A
2015-01-01
We present a case on conservative management of salvaging the mesh in an immunocompromised morbidly obese patient, who developed a synergistic gangrene infection following a primary open mesh repair of an incisional hernia. Our patient presented with a surgical wound infection, comorbidities were Chronic Lymphoblastic Leukemia (CLL), Body Mass Index (BMI) of 50, hypertension and diet controlled type-2 diabetes. In surgery, wide necrotic wound debridement, early and repetitive wound drainages with the use of a large pore polypropylene mesh and a detailed surgical follow up was required. High dose intravenous broad-spectrum antibiotic treatment and Negative Pressure Wound Therapy (NPWT) was administrated in combination with adopting a multidisciplinary approach was key to our success. Stoppa Re et al. complied a series of 360 ventral hernia mesh repairs reporting an infection rate of 12% that were managed conservatively. However, our selective case is unique within current literature, being the first to illustrate mesh salvage in a morbid obese patient with CLL. Recent modifications in mesh morphology, such as lower density, wide pores, and lighter weight has led to considerable improvements regarding infection avoidance. This case has demonstrated how a planned multidisciplinary action can produce prosperous results in a severely obese immunocompromised patient with an SSI, following an incisional hernia repair. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Parallel flow diffusion battery
Yeh, H.C.; Cheng, Y.S.
1984-01-01
A parallel flow diffusion battery for determining the mass distribution of an aerosol has a plurality of diffusion cells mounted in parallel to an aerosol stream, each diffusion cell including a stack of mesh wire screens of different density.
Parallel flow diffusion battery
Yeh, Hsu-Chi; Cheng, Yung-Sung
1984-08-07
A parallel flow diffusion battery for determining the mass distribution of an aerosol has a plurality of diffusion cells mounted in parallel to an aerosol stream, each diffusion cell including a stack of mesh wire screens of different density.
NASA Astrophysics Data System (ADS)
Ren, Zhengyong; Qiu, Lewen; Tang, Jingtian; Wu, Xiaoping; Xiao, Xiao; Zhou, Zilong
2018-01-01
Although accurate numerical solvers for 3-D direct current (DC) isotropic resistivity models are current available even for complicated models with topography, reliable numerical solvers for the anisotropic case are still an open question. This study aims to develop a novel and optimal numerical solver for accurately calculating the DC potentials for complicated models with arbitrary anisotropic conductivity structures in the Earth. First, a secondary potential boundary value problem is derived by considering the topography and the anisotropic conductivity. Then, two a posteriori error estimators with one using the gradient-recovery technique and one measuring the discontinuity of the normal component of current density are developed for the anisotropic cases. Combing the goal-oriented and non-goal-oriented mesh refinements and these two error estimators, four different solving strategies are developed for complicated DC anisotropic forward modelling problems. A synthetic anisotropic two-layer model with analytic solutions verified the accuracy of our algorithms. A half-space model with a buried anisotropic cube and a mountain-valley model are adopted to test the convergence rates of these four solving strategies. We found that the error estimator based on the discontinuity of current density shows better performance than the gradient-recovery based a posteriori error estimator for anisotropic models with conductivity contrasts. Both error estimators working together with goal-oriented concepts can offer optimal mesh density distributions and highly accurate solutions.
A Novel Approach to Visualizing Dark Matter Simulations.
Kaehler, R; Hahn, O; Abel, T
2012-12-01
In the last decades cosmological N-body dark matter simulations have enabled ab initio studies of the formation of structure in the Universe. Gravity amplified small density fluctuations generated shortly after the Big Bang, leading to the formation of galaxies in the cosmic web. These calculations have led to a growing demand for methods to analyze time-dependent particle based simulations. Rendering methods for such N-body simulation data usually employ some kind of splatting approach via point based rendering primitives and approximate the spatial distributions of physical quantities using kernel interpolation techniques, common in SPH (Smoothed Particle Hydrodynamics)-codes. This paper proposes three GPU-assisted rendering approaches, based on a new, more accurate method to compute the physical densities of dark matter simulation data. It uses full phase-space information to generate a tetrahedral tessellation of the computational domain, with mesh vertices defined by the simulation's dark matter particle positions. Over time the mesh is deformed by gravitational forces, causing the tetrahedral cells to warp and overlap. The new methods are well suited to visualize the cosmic web. In particular they preserve caustics, regions of high density that emerge, when several streams of dark matter particles share the same location in space, indicating the formation of structures like sheets, filaments and halos. We demonstrate the superior image quality of the new approaches in a comparison with three standard rendering techniques for N-body simulation data.
Comparison of Hall Thruster Plume Expansion Model with Experimental Data
2006-05-23
focus of this study, is a hybrid particle- in-cell ( PIC ) model that tracks particles along an unstructured tetrahedral mesh. * Research Engineer...measurements of the ion current density profile, ion energy distributions, and ion species fraction distributions using a nude Faraday probe, retarding...Vol.37 No.1. 6 Oh, D. and Hastings, D., “Three Dimensional PIC -DSMC Simulations of Hall Thruster Plumes and Analysis for Realistic Spacecraft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gleicher, Frederick; Ortensi, Javier; DeHart, Mark
Accurate calculation of desired quantities to predict fuel behavior requires the solution of interlinked equations representing different physics. Traditional fuels performance codes often rely on internal empirical models for the pin power density and a simplified boundary condition on the cladding edge. These simplifications are performed because of the difficulty of coupling applications or codes on differing domains and mapping the required data. To demonstrate an approach closer to first principles, the neutronics application Rattlesnake and the thermal hydraulics application RELAP-7 were coupled to the fuels performance application BISON under the master application MAMMOTH. A single fuel pin was modeledmore » based on the dimensions of a Westinghouse 17x17 fuel rod. The simulation consisted of a depletion period of 1343 days, roughly equal to three full operating cycles, followed by a station blackout (SBO) event. The fuel rod was depleted for 1343 days for a near constant total power loading of 65.81 kW. After 1343 days the fission power was reduced to zero (simulating a reactor shut-down). Decay heat calculations provided the time-varying energy source after this time. For this problem, Rattlesnake, BISON, and RELAP-7 are coupled under MAMMOTH in a split operator approach. Each system solves its physics on a separate mesh and, for RELAP-7 and BISON, on only a subset of the full problem domain. Rattlesnake solves the neutronics over the whole domain that includes the fuel, cladding, gaps, water, and top and bottom rod holders. Here BISON is applied to the fuel and cladding with a 2D axi-symmetric domain, and RELAP-7 is applied to the flow of the circular outer water channel with a set of 1D flow equations. The mesh on the Rattlesnake side can either be 3D (for low order transport) or 2D (for diffusion). BISON has a matching ring structure mesh for the fuel so both the power density and local burn up are copied accurately from Rattlesnake. At each depletion time step, Rattlesnake calculates a power density, fission density rate, burn-up distribution and fast flux based on the current water density and fuel temperature. These are then mapped to the BISON mesh for a fuels performance solve. BISON calculates the fuel temperature and cladding surface temperature based upon the current power density and bulk fluid temperature. RELAP-7 then calculates the fluid temperature, water density fraction and water phase velocity based upon the cladding surface temperature. The fuel temperature and the fluid density are then passed back to Rattlesnake for another neutronics calculation. Six Picard or fixed-point style iterations are preformed in this manner to obtain consistent tightly coupled and stable results. For this paper a set of results from the detailed calculation are provided for both during depletion and the SBO event. We demonstrate that a detailed calculation closer to first principles can be done under MAMMOTH between different applications on differing domains.« less
NASA Astrophysics Data System (ADS)
Sonntag, Simon J.; Kaufmann, Tim A. S.; Büsen, Martin R.; Laumen, Marco; Linde, Torsten; Schmitz-Rode, Thomas; Steinseifer, Ulrich
2013-04-01
Heart disease is one of the leading causes of death in the world. Due to a shortage in donor organs artificial hearts can be a bridge to transplantation or even serve as a destination therapy for patients with terminal heart insufficiency. A pusher plate driven pulsatile membrane pump, the Total Artificial Heart (TAH) ReinHeart, is currently under development at the Institute of Applied Medical Engineering of RWTH Aachen University.This paper presents the methodology of a fully coupled three-dimensional time-dependent Fluid Structure Interaction (FSI) simulation of the TAH using a commercial partitioned block-Gauss-Seidel coupling package. Partitioned coupling of the incompressible fluid with the slender flexible membrane as well as a high fluid/structure density ratio of about unity led inherently to a deterioration of the stability (‘artificial added mass instability’). The objective was to conduct a stable simulation with high accuracy of the pumping process. In order to achieve stability, a combined resistance and pressure outlet boundary condition as well as the interface artificial compressibility method was applied. An analysis of the contact algorithm and turbulence condition is presented. Independence tests are performed for the structural and the fluid mesh, the time step size and the number of pulse cycles. Because of the large deformation of the fluid domain, a variable mesh stiffness depending on certain mesh properties was specified for the fluid elements. Adaptive remeshing was avoided. Different approaches for the mesh stiffness function are compared with respect to convergence, preservation of mesh topology and mesh quality. The resulting mesh aspect ratios, mesh expansion factors and mesh orthogonalities are evaluated in detail. The membrane motion and flow distribution of the coupled simulations are compared with a top-view recording and stereo Particle Image Velocimetry (PIV) measurements, respectively, of the actual pump.
NASA Astrophysics Data System (ADS)
Heya, Akira; Matsuo, Naoto
2018-04-01
The guidelines for a bottom-up approach of nanographene formation from pentacene using heated tungsten were investigated using a novel method called hot mesh deposition (HMD). In this method, a heated W mesh was set between a pentacene source and a quartz substrate. Pentacene molecules were decomposed by the heated W mesh. The generated pentacene-based decomposed precursors were then deposited on the quartz substrate. The pentacene dimer (peripentacene) was obtained from pentacene by HMD using two heated catalysts. As expected from the calculation with the density functional theory in the literature, it was confirmed that the pentacene dimer can be formed by a reaction between pentacene and 6,13-dihydropentacene. This technique can be applied to the formation of novel nanographene on various substrates without metal catalysts.
A performance comparison of ultrasonically aided electric propulsion extractor configurations
NASA Astrophysics Data System (ADS)
Dong, L.; Song, W.; Kang, X. M.; Zhao, W. S.
2012-08-01
As a novel propulsion technology, ultrasonically aided electric propulsion (UAEP) offers a high specific impulse and a high thrust density. In this paper, the effects of extractor grid configuration on performance of a UAEP thruster have been investigated by both experimental studies and numerical simulation. Relationships between spray current and operation parameters, including applied voltage, propellant flow rate, and vibration power and frequency, are explored for different extractor mesh sizes and shapes. Numerical simulation is also carried out for a better understanding of the formation of capillary standing waves as well as the electric field distribution in the acceleration zone. Experimental results show that compared with a circular shaped extractor, a reticular shaped extractor is able to produce a higher spray current. The current density increases with a denser mesh, which agrees well with the numerical simulation results. This phenomenon indicates that optimizing extractors with appropriate shapes and sizes can be an effective way to improve the performance of a UAEP system. A performance evaluation based on hydrodynamic and electrostatic calculations indicates that the present UAEP system can produce a thrust competitive to that of the colloid thruster with an emitter array.
Automatic two- and three-dimensional mesh generation based on fuzzy knowledge processing
NASA Astrophysics Data System (ADS)
Yagawa, G.; Yoshimura, S.; Soneda, N.; Nakao, K.
1992-09-01
This paper describes the development of a novel automatic FEM mesh generation algorithm based on the fuzzy knowledge processing technique. A number of local nodal patterns are stored in a nodal pattern database of the mesh generation system. These nodal patterns are determined a priori based on certain theories or past experience of experts of FEM analyses. For example, such human experts can determine certain nodal patterns suitable for stress concentration analyses of cracks, corners, holes and so on. Each nodal pattern possesses a membership function and a procedure of node placement according to this function. In the cases of the nodal patterns for stress concentration regions, the membership function which is utilized in the fuzzy knowledge processing has two meanings, i.e. the “closeness” of nodal location to each stress concentration field as well as “nodal density”. This is attributed to the fact that a denser nodal pattern is required near a stress concentration field. What a user has to do in a practical mesh generation process are to choose several local nodal patterns properly and to designate the maximum nodal density of each pattern. After those simple operations by the user, the system places the chosen nodal patterns automatically in an analysis domain and on its boundary, and connects them smoothly by the fuzzy knowledge processing technique. Then triangular or tetrahedral elements are generated by means of the advancing front method. The key issue of the present algorithm is an easy control of complex two- or three-dimensional nodal density distribution by means of the fuzzy knowledge processing technique. To demonstrate fundamental performances of the present algorithm, a prototype system was constructed with one of object-oriented languages, Smalltalk-80 on a 32-bit microcomputer, Macintosh II. The mesh generation of several two- and three-dimensional domains with cracks, holes and junctions was presented as examples.
Electromagnetic Scattering From a Polygonal Thin Metallic Plate Using Quadrilateral Meshing
NASA Technical Reports Server (NTRS)
Deshpande, Manohar D.
2003-01-01
The problem of electromagnetic (EM) scattering from irregularly shaped, thin, metallic flat plates in free space is solved using the electric field integral equation (EFIE) approach in conjunction with the method of moments (MoM) with quadrilateral meshing. An irregularly shaped thin plate is discretized into quadrilateral patches and the unknown electric surface current over the plate is expressed in terms of proper basis functions over these patches. The basis functions for the electric surface current density that satisfy the proper boundary conditions on these quadrilateral patches are derived. The unknown surface current density on these quadrilateral patches is determined by setting up and solving the electric field integral equation by the application of the MoM. From the knowledge of the surface current density, the EM scattering from various irregularly shaped plates is determined and compared with the earlier published results. The novelty in the present approach is the use of quadrilateral patches instead of well known and often used triangular patches. The numerical results obtained using the quadrilateral patches compare favorably with measured results.
Natural gas storage with activated carbon from a bituminous coal
Sun, Jielun; Rood, M.J.; Rostam-Abadi, M.; Lizzio, A.A.
1996-01-01
Granular activated carbons ( -20 + 100 mesh; 0.149-0.84 mm) were produced by physical activation and chemical activation with KOH from an Illinois bituminous coal (IBC-106) for natural gas storage. The products were characterized by BET surface area, micropore volume, bulk density, and methane adsorption capacities. Volumetric methane adsorption capacities (Vm/Vs) of some of the granular carbons produced by physical activation are about 70 cm3/cm3 which is comparable to that of BPL, a commercial activated carbon. Vm/Vs values above 100 cm3/cm3 are obtainable by grinding the granular products to - 325 mesh (<0.044 mm). The increase in Vm/Vs is due to the increase in bulk density of the carbons. Volumetric methane adsorption capacity increases with increasing pore surface area and micropore volume when normalizing with respect to sample bulk volume. Compared with steam-activated carbons, granular carbons produced by KOH activation have higher micropore volume and higher methane adsorption capacities (g/g). Their volumetric methane adsorption capacities are lower due to their lower bulk densities. Copyright ?? 1996 Elsevier Science Ltd.
Shrink-wrapped isosurface from cross sectional images
Choi, Y. K.; Hahn, J. K.
2010-01-01
Summary This paper addresses a new surface reconstruction scheme for approximating the isosurface from a set of tomographic cross sectional images. Differently from the novel Marching Cubes (MC) algorithm, our method does not extract the iso-density surface (isosurface) directly from the voxel data but calculates the iso-density point (isopoint) first. After building a coarse initial mesh approximating the ideal isosurface by the cell-boundary representation, it metamorphoses the mesh into the final isosurface by a relaxation scheme, called shrink-wrapping process. Compared with the MC algorithm, our method is robust and does not make any cracks on surface. Furthermore, since it is possible to utilize lots of additional isopoints during the surface reconstruction process by extending the adjacency definition, theoretically the resulting surface can be better in quality than the MC algorithm. According to experiments, it is proved to be very robust and efficient for isosurface reconstruction from cross sectional images. PMID:20703361
Gelatin Methacrylate Microspheres for Growth Factor Controlled Release
Nguyen, Anh H.; McKinney, Jay; Miller, Tobias; Bongiorno, Tom; McDevitt, Todd C.
2014-01-01
Gelatin has been commonly used as a delivery vehicle for various biomolecules for tissue engineering and regenerative medicine applications due to its simple fabrication methods, inherent electrostatic binding properties, and proteolytic degradability. Compared to traditional chemical cross-linking methods, such as the use of glutaraldehyde (GA), methacrylate modification of gelatin offers an alternative method to better control the extent of hydrogel cross-linking. Here we examined the physical properties and growth factor delivery of gelatin methacrylate (GMA) microparticles formulated with a wide range of different cross-linking densities (15–90%). Less methacrylated MPs had decreased elastic moduli and larger mesh sizes compared to GA MPs, with increasing methacrylation correlating to greater moduli and smaller mesh sizes. As expected, an inverse correlation between microparticle cross-linking density and degradation was observed, with the lowest cross-linked GMA MPs degrading at the fastest rate, comparable to GA MPs. Interestingly, GMA MPs at lower cross-linking densities could be loaded with up to a 10-fold higher relative amount of growth factor over conventional GA cross-linked MPs, despite an order of magnitude greater gelatin content of GA MPs. Moreover, a reduced GMA cross-linking density resulted in more complete release of bone morphogenic protein 4 (BMP4) and basic fibroblast growth factor (bFGF) and accelerated release rate with collagenase treatment. These studies demonstrate that GMA MPs provide a more flexible platform for growth factor delivery by enhancing the relative binding capacity and permitting proteolytic degradation tunability, thereby offering a more potent controlled release system for growth factor delivery. PMID:25463489
Convergence study of global meshing on enamel-cement-bracket finite element model
NASA Astrophysics Data System (ADS)
Samshuri, S. F.; Daud, R.; Rojan, M. A.; Basaruddin, K. S.; Abdullah, A. B.; Ariffin, A. K.
2017-09-01
This paper presents on meshing convergence analysis of finite element (FE) model to simulate enamel-cement-bracket fracture. Three different materials used in this study involving interface fracture are concerned. Complex behavior ofinterface fracture due to stress concentration is the reason to have a well-constructed meshing strategy. In FE analysis, meshing size is a critical factor that influenced the accuracy and computational time of analysis. The convergence study meshing scheme involving critical area (CA) and non-critical area (NCA) to ensure an optimum meshing sizes are acquired for this FE model. For NCA meshing, the area of interest are at the back of enamel, bracket ligature groove and bracket wing. For CA meshing, area of interest are enamel area close to cement layer, the cement layer and bracket base. The value of constant NCA meshing tested are meshing size 1 and 0.4. The value constant CA meshing tested are 0.4 and 0.1. Manipulative variables are randomly selected and must abide the rule of NCA must be higher than CA. This study employed first principle stresses due to brittle failure nature of the materials used. Best meshing size are selected according to convergence error analysis. Results show that, constant CA are more stable compare to constant NCA meshing. Then, 0.05 constant CA meshing are tested to test the accuracy of smaller meshing. However, unpromising result obtained as the errors are increasing. Thus, constant CA 0.1 with NCA mesh of 0.15 until 0.3 are the most stable meshing as the error in this region are lowest. Convergence test was conducted on three selected coarse, medium and fine meshes at the range of NCA mesh of 0.15 until 3 and CA mesh area stay constant at 0.1. The result shows that, at coarse mesh 0.3, the error are 0.0003% compare to 3% acceptable error. Hence, the global meshing are converge as the meshing size at CA 0.1 and NCA 0.15 for this model.
Unstructured Finite Elements and Dynamic Meshing for Explicit Phase Tracking in Multiphase Problems
NASA Astrophysics Data System (ADS)
Chandra, Anirban; Yang, Fan; Zhang, Yu; Shams, Ehsan; Sahni, Onkar; Oberai, Assad; Shephard, Mark
2017-11-01
Multi-phase processes involving phase change at interfaces, such as evaporation of a liquid or combustion of a solid, represent an interesting class of problems with varied applications. Large density ratio across phases, discontinuous fields at the interface and rapidly evolving geometries are some of the inherent challenges which influence the numerical modeling of multi-phase phase change problems. In this work, a mathematically consistent and robust computational approach to address these issues is presented. We use stabilized finite element methods on mixed topology unstructured grids for solving the compressible Navier-Stokes equations. Appropriate jump conditions derived from conservations laws across the interface are handled by using discontinuous interpolations, while the continuity of temperature and tangential velocity is enforced using a penalty parameter. The arbitrary Lagrangian-Eulerian (ALE) technique is utilized to explicitly track the interface motion. Mesh at the interface is constrained to move with the interface while elsewhere it is moved using the linear elasticity analogy. Repositioning is applied to the layered mesh that maintains its structure and normal resolution. In addition, mesh modification is used to preserve the quality of the volumetric mesh. This work is supported by the U.S. Army Grants W911NF1410301 and W911NF16C0117.
Zhang, Yeshui; Nahil, Mohamad A; Wu, Chunfei; Williams, Paul T
2017-11-01
A stainless-steel mesh loaded with nickel catalyst was produced and used for the pyrolysis-catalysis of waste high-density polyethylene with the aim of producing high-value carbon products, including carbon nanotubes (CNTs). The catalysis temperature and plastic-to-catalyst ratio were investigated to determine the influence on the formation of different types of carbon deposited on the nickel-stainless-steel mesh catalyst. Increasing temperature from 700 to 900°C resulted in an increase in the carbon deposited on the nickel-loaded stainless-steel mesh catalyst from 32.5 to 38.0 wt%. The increase in sample-to-catalyst ratio reduced the amount of carbon deposited on the mesh catalyst in terms of g carbon g -1 plastic. The carbons were found to be largely composed of filamentous carbons, with negligible disordered (amorphous) carbons. Transmission electron microscopy analysis of the filamentous carbons revealed them to be composed of a large proportion (estimated at ∼40%) multi-walled carbon nanotubes (MWCNTs). The optimum process conditions for CNT production, in terms of yield and graphitic nature, determined by Raman spectroscopy, was catalysis temperature of 800°C and plastic-to-catalyst ratio of 1:2, where a mass of 334 mg of filamentous/MWCNTs g -1 plastic was produced.
Murr, L E; Amato, K N; Li, S J; Tian, Y X; Cheng, X Y; Gaytan, S M; Martinez, E; Shindo, P W; Medina, F; Wicker, R B
2011-10-01
Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platelets while the mesh and foam structures were characterized by α(')-martensite with some residual α. The Co-29Cr-6Mo containing 0.22% C formed columnar (directional) Cr(23)C(6) carbides spaced ~2 μm in the build direction, while HIP-annealed Co-Cr alloy exhibited an intrinsic stacking fault microstructure. A log-log plot of relative stiffness versus relative density for Ti-6Al-4V and Co-29Cr-6Mo open-cellular mesh and foams resulted in a fitted line with a nearly ideal slope, n = 2.1. A stress shielding design graph constructed from these data permitted mesh and foam implant prototypes to be fabricated for compatible bone stiffness. Copyright © 2011 Elsevier Ltd. All rights reserved.
Vibration characteristics of OH-58A helicopter main rotor transmission
NASA Technical Reports Server (NTRS)
Lewicki, David G.; Coy, John J.
1987-01-01
Experimental vibration tests covering a range of torque and speed conditions were performed on the OH-58A helicopter main rotor transmission at the NASA Lewis Research Center. Signals from accelerometers located on the transmission housing were analyzed by using Fourier spectra, power spectral density functions, and averaging techniques. Most peaks of the Fourier spectra occurred at the spiral bevel and planetary gear mesh harmonics. The highest level of vibration occurred at the spiral bevel meshing frequency. Transmission speed and vibration measurement location had a significant effect on measured vibration; transmission torque and measurement direction had a small effect.
Accurate evaluation of exchange fields in finite element micromagnetic solvers
NASA Astrophysics Data System (ADS)
Chang, R.; Escobar, M. A.; Li, S.; Lubarda, M. V.; Lomakin, V.
2012-04-01
Quadratic basis functions (QBFs) are implemented for solving the Landau-Lifshitz-Gilbert equation via the finite element method. This involves the introduction of a set of special testing functions compatible with the QBFs for evaluating the Laplacian operator. The results by using QBFs are significantly more accurate than those via linear basis functions. QBF approach leads to significantly more accurate results than conventionally used approaches based on linear basis functions. Importantly QBFs allow reducing the error of computing the exchange field by increasing the mesh density for structured and unstructured meshes. Numerical examples demonstrate the feasibility of the method.
NASA Astrophysics Data System (ADS)
Ramirez, Diana Alejandra
The fabrication of Cu components were first built by additive manufacturing using electron beam melting (EBM) from low-purity, atomized Cu powder containing a high density of Cu2O precipitates leading to a novel example of precipitate-dislocation architecture. These microstructures exhibit cell-like arrays (1-3microm) in the horizontal reference plane perpendicular to the build direction with columnar-like arrays extending from ~12 to >60 microm in length and corresponding spatial dimensions of 1-3 microm. These observations were observed by the use of optical metallography, and scanning and transmission electron microscopy. The hardness measurements were taken both on the atomized powder and the Cu components. The hardness for these architectures ranged from ~HV 83 to 88, in contrast to the original Cu powder microindentation hardness of HV 72 and the commercial Cu base plate hardness of HV 57. These observations were utilized for the fabrication of open-cellular copper structures by additive manufacturing using EBM and illustrated the ability to fabricate some form of controlled microstructural architecture by EBM parameter alteration or optimizing. The fabrication of these structures ranged in densities from 0.73g/cm3 to 6.67g/cm3. These structures correspond to four different articulated mesh arrays. While these components contained some porosity as a consequence of some unmelted regions, the Cu2O precipitates also contributed to a reduced density. Using X-ray Diffraction showed the approximate volume fraction estimated to be ~2%. The addition of precipitates created in the EBM melt scan formed microstructural arrays which contributed to hardening contributing to the strength of mesh struts and foam ligaments. The measurements of relative stiffness versus relative density plots for Cu compared very closely with Ti-6Al-4V open cellular structures - both mesh and foams. The Cu reticulated mesh structures exhibit a slope of n = 2 in contrast to a slope of n = 2.4 for the stochastic Cu foams, consistent with the Gibson-Ashby foam model where n = 2. These open cellular structure components exhibit considerable potential for novel, complex, multi-functional electrical and thermal management systems, especially complex, monolithic heat exchange device.
NASA Technical Reports Server (NTRS)
Bibel, George; Lewicki, David G. (Technical Monitor)
2002-01-01
A procedure was developed to perform tooth contact analysis between a face gear meshing with a spur pinion using finite element analysis. The face gear surface points from a previous analysis were used to create a connected tooth solid model without gaps or overlaps. The face gear surface points were used to create a five tooth face gear Patran model (with rim) using Patran PCL commands. These commands were saved in a series of session files suitable for Patran input. A four tooth spur gear that meshes with the face gear was designed and constructed with Patran PCL commands. These commands were also saved in a session files suitable for Patran input. The orientation of the spur gear required for meshing with the face gear was determined. The required rotations and translations are described and built into the session file for the spur gear. The Abaqus commands for three-dimensional meshing were determined and verified for a simplified model containing one spur tooth and one face gear tooth. The boundary conditions, loads, and weak spring constraints were determined to make the simplified model work. The load steps and load increments to establish contact and obtain a realistic load was determined for the simplified two tooth model. Contact patterns give some insight into required mesh density. Building the two gears in two different local coordinate systems and rotating the local coordinate systems was verified as an easy way to roll the gearset through mesh. Due to limitation of swap space, disk space and time constraints of the summer period, the larger model was not completed.
NASA Technical Reports Server (NTRS)
Papazian, Peter B.; Perala, Rodney A.; Curry, John D.; Lankford, Alan B.; Keller, J. David
1988-01-01
Using three different current injection methods and a simple voltage probe, transfer impedances for Solid Rocket Motor (SRM) joints, wire meshes, aluminum foil, Thorstrand and a graphite composite motor case were measured. In all cases, the surface current distribution for the particular current injection device was calculated analytically or by finite difference methods. The results of these calculations were used to generate a geometric factor which was the ratio of total injected current to surface current density. The results were validated in several ways. For wire mesh measurements, results showed good agreement with calculated results for a 14 by 18 Al screen. SRM joint impedances were independently verified. The filiment wound case measurement results were validated only to the extent that their curve shape agrees with the expected form of transfer impedance for a homogeneous slab excited by a plane wave source.
Accurate Grid-based Clustering Algorithm with Diagonal Grid Searching and Merging
NASA Astrophysics Data System (ADS)
Liu, Feng; Ye, Chengcheng; Zhu, Erzhou
2017-09-01
Due to the advent of big data, data mining technology has attracted more and more attentions. As an important data analysis method, grid clustering algorithm is fast but with relatively lower accuracy. This paper presents an improved clustering algorithm combined with grid and density parameters. The algorithm first divides the data space into the valid meshes and invalid meshes through grid parameters. Secondly, from the starting point located at the first point of the diagonal of the grids, the algorithm takes the direction of “horizontal right, vertical down” to merge the valid meshes. Furthermore, by the boundary grid processing, the invalid grids are searched and merged when the adjacent left, above, and diagonal-direction grids are all the valid ones. By doing this, the accuracy of clustering is improved. The experimental results have shown that the proposed algorithm is accuracy and relatively faster when compared with some popularly used algorithms.
The formation of disc galaxies in high-resolution moving-mesh cosmological simulations
NASA Astrophysics Data System (ADS)
Marinacci, Federico; Pakmor, Rüdiger; Springel, Volker
2014-01-01
We present cosmological hydrodynamical simulations of eight Milky Way-sized haloes that have been previously studied with dark matter only in the Aquarius project. For the first time, we employ the moving-mesh code AREPO in zoom simulations combined with a comprehensive model for galaxy formation physics designed for large cosmological simulations. Our simulations form in most of the eight haloes strongly disc-dominated systems with realistic rotation curves, close to exponential surface density profiles, a stellar mass to halo mass ratio that matches expectations from abundance matching techniques, and galaxy sizes and ages consistent with expectations from large galaxy surveys in the local Universe. There is no evidence for any dark matter core formation in our simulations, even so they include repeated baryonic outflows by supernova-driven winds and black hole quasar feedback. For one of our haloes, the object studied in the recent `Aquila' code comparison project, we carried out a resolution study with our techniques, covering a dynamic range of 64 in mass resolution. Without any change in our feedback parameters, the final galaxy properties are reassuringly similar, in contrast to other modelling techniques used in the field that are inherently resolution dependent. This success in producing realistic disc galaxies is reached, in the context of our interstellar medium treatment, without resorting to a high density threshold for star formation, a low star formation efficiency, or early stellar feedback, factors deemed crucial for disc formation by other recent numerical studies.
Köckerling, F; Alam, N N; Antoniou, S A; Daniels, I R; Famiglietti, F; Fortelny, R H; Heiss, M M; Kallinowski, F; Kyle-Leinhase, I; Mayer, F; Miserez, M; Montgomery, A; Morales-Conde, S; Muysoms, F; Narang, S K; Petter-Puchner, A; Reinpold, W; Scheuerlein, H; Smietanski, M; Stechemesser, B; Strey, C; Woeste, G; Smart, N J
2018-04-01
Although many surgeons have adopted the use of biologic and biosynthetic meshes in complex abdominal wall hernia repair, others have questioned the use of these products. Criticism is addressed in several review articles on the poor standard of studies reporting on the use of biologic meshes for different abdominal wall repairs. The aim of this consensus review is to conduct an evidence-based analysis of the efficacy of biologic and biosynthetic meshes in predefined clinical situations. A European working group, "BioMesh Study Group", composed of invited surgeons with a special interest in surgical meshes, formulated key questions, and forwarded them for processing in subgroups. In January 2016, a workshop was held in Berlin where the findings were presented, discussed, and voted on for consensus. Findings were set out in writing by the subgroups followed by consensus being reached. For the review, 114 studies and background analyses were used. The cumulative data regarding biologic mesh under contaminated conditions do not support the claim that it is better than synthetic mesh. Biologic mesh use should be avoided when bridging is needed. In inguinal hernia repair biologic and biosynthetic meshes do not have a clear advantage over the synthetic meshes. For prevention of incisional or parastomal hernias, there is no evidence to support the use of biologic/biosynthetic meshes. In complex abdominal wall hernia repairs (incarcerated hernia, parastomal hernia, infected mesh, open abdomen, enterocutaneous fistula, and component separation technique), biologic and biosynthetic meshes do not provide a superior alternative to synthetic meshes. The routine use of biologic and biosynthetic meshes cannot be recommended.
Passalía, Claudio; Nocetti, Emanuel; Alfano, Orlando; Brandi, Rodolfo
2017-03-01
An experimental comparative study of different meshes as support materials for photocatalytic applications in gas phase is presented. The photocatalytic oxidation of dichloromethane in air was addressed employing different coated meshes in a laboratory-scale, continuous reactor. Two fiberglass meshes and a stainless steel mesh were studied regarding the catalyst load, adherence, and catalytic activity. Titanium dioxide photocatalyst was immobilized on the meshes by dip-coating cycles. Results indicate the feasibility of the dichloromethane elimination in the three cases. When the number of coating cycles was doubled, the achieved conversion levels were increased twofold for stainless steel and threefold for the fiberglass meshes. One of the fiberglass meshes (FG2) showed the highest reactivity per mass of catalyst and per catalytic surface area.
Initial Comparison of Direct and Legacy Modeling Approaches for Radial Core Expansion Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shemon, Emily R.
2016-10-10
Radial core expansion in sodium-cooled fast reactors provides an important reactivity feedback effect. As the reactor power increases due to normal start up conditions or accident scenarios, the core and surrounding materials heat up, causing both grid plate expansion and bowing of the assembly ducts. When the core restraint system is designed correctly, the resulting structural deformations introduce negative reactivity which decreases the reactor power. Historically, an indirect procedure has been used to estimate the reactivity feedback due to structural deformation which relies upon perturbation theory and coupling legacy physics codes with limited geometry capabilities. With advancements in modeling andmore » simulation, radial core expansion phenomena can now be modeled directly, providing an assessment of the accuracy of the reactivity feedback coefficients generated by indirect legacy methods. Recently a new capability was added to the PROTEUS-SN unstructured geometry neutron transport solver to analyze deformed meshes quickly and directly. By supplying the deformed mesh in addition to the base configuration input files, PROTEUS-SN automatically processes material adjustments including calculation of region densities to conserve mass, calculation of isotopic densities according to material models (for example, sodium density as a function of temperature), and subsequent re-homogenization of materials. To verify the new capability of directly simulating deformed meshes, PROTEUS-SN was used to compute reactivity feedback for a series of contrived yet representative deformed configurations for the Advanced Burner Test Reactor design. The indirect legacy procedure was also performed to generate reactivity feedback coefficients for the same deformed configurations. Interestingly, the legacy procedure consistently overestimated reactivity feedbacks by 35% compared to direct simulations by PROTEUS-SN. This overestimation indicates that the legacy procedures are in fact not conservative and could be overestimating reactivity feedback effects that are closely tied to reactor safety. We conclude that there is indeed value in performing direct simulation of deformed meshes despite the increased computational expense. PROTEUS-SN is already part of the SHARP multi-physics toolkit where both thermal hydraulics and structural mechanical feedback modeling can be applied but this is the first comparison of direct simulation to legacy techniques for radial core expansion.« less
Khandaker, Morshed; Riahinezhad, Shahram; Williams, Wendy R.; Wolf, Roman
2017-01-01
The effect of depositing a collagen (CG)-poly-ε-caprolactone (PCL) nanofiber mesh (NFM) at the microgrooves of titanium (Ti) on the mechanical stability and osseointegration of the implant with bone was investigated using a rabbit model. Three groups of Ti samples were produced: control Ti samples where there were no microgrooves or CG-PCL NFM, groove Ti samples where microgrooves were machined on the circumference of Ti, and groove-NFM Ti samples where CG-PCL NFM was deposited on the machined microgrooves. Each group of Ti samples was implanted in the rabbit femurs for eight weeks. The mechanical stability of the Ti/bone samples were quantified by shear strength from a pullout tension test. Implant osseointegration was evaluated by a histomorphometric analysis of the percentage of bone and connective tissue contact with the implant surface. The bone density around the Ti was measured by micro–computed tomography (μCT) analysis. This study found that the shear strength of groove-NFM Ti/bone samples was significantly higher compared to control and groove Ti/bone samples (p < 0.05) and NFM coating influenced the bone density around Ti samples. In vivo histomorphometric analyses show that bone growth into the Ti surface increased by filling the microgrooves with CG-PCL NFM. The study concludes that a microgroove assisted CG-PCL NFM coating may benefit orthopedic implants. PMID:28608839
Investigating the importance of flow when utilizing hyaluronan scaffolds for tissue engineering.
Donegan, Gail C; Hunt, John A; Rhodes, Nicholas
2010-02-01
Esterified hyaluronan scaffolds offer significant advantages for tissue engineering. They are recognized by cellular receptors, interact with many other extracellular matrix proteins and their metabolism is mediated by intrinsic cellular pathways. In this study differences in the viability and structural integrity of vascular tissue models cultured on hyaluronan scaffolds under laminar flow conditions highlighted potential differences in the biodegradation kinetics, processes and end-products, depending on the culture environment. Critical factors are likely to include seeding densities and the duration and magnitude of applied biomechanical stress. Proteomic evaluation of the timing and amount of remodelling protein expression, the resulting biomechanical changes arising from this response and metabolic cell viability assay, together with examination of tissue morphology, were conducted in vascular tissue models cultured on esterified hyaluronan felt and PTFE mesh scaffolds. The vascular tissue models were derived using complete cell sheets derived from harvested and expanded umbilical cord vein cells. This seeding method utilizes high-density cell populations from the outset, while the cells are already supported by their own abundant extracellular matrix. Type I and type IV collagen expression in parallel with MMP-1 and MMP-2 expression were monitored in the tissue models over a 10 day culture period under laminar flow regimes using protein immobilization technologies. Uniaxial tensile testing and scanning electron microscopy were used to compare the resulting effects of hydrodynamic stimulation upon structural integrity, while viability assays were conducted to evaluate the effects of shear on metabolic function. The proteomic results showed that the hyaluronan felt-supported tissues expressed higher levels of all remodelling proteins than those cultured on PTFE mesh. Overall, a 21% greater expression of type I collagen, 24% higher levels of type IV collagen, 24% higher levels of MMP-1 and 34% more MMP-2 were observed during hydrodynamic stress. This was coupled with a loss of structural integrity in these models after the introduction of laminar flow, as compared to the increases in all mechanical properties observed in the PTFE mesh-supported tissues. However, under flow conditions, the hyaluronan-supported tissues showed some recovery of the viability originally lost during static culture conditions, in contrast to PTFE mesh-based models, where initial gains were followed by a decline in metabolic viability after applied shear stress. Proteomic, cell viability and mechanical testing data emphasized the need for extended in vitro evaluations to enable better understanding of multi-stage remodelling and reparative processes in tissues cultured on biodegradable scaffolds. This study also highlighted the possibility that in high-density tissue culture with a biodegradable component, dynamic conditions may be more conducive to optimal tissue development than the static environment because they facilitate the efficient removal of high concentrations of degradation end-products accumulating in the pericellular space.
NASA Astrophysics Data System (ADS)
Guo, Zhikui; Chen, Chao; Tao, Chunhui
2016-04-01
Since 2007, there are four China Da yang cruises (CDCs), which have been carried out to investigate polymetallic sulfides in the southwest Indian ridge (SWIR) and have acquired both gravity data and bathymetry data on the corresponding survey lines(Tao et al., 2014). Sandwell et al. (2014) published a new global marine gravity model including the free air gravity data and its first order vertical gradient (Vzz). Gravity data and its gradient can be used to extract unknown density structure information(e.g. crust thickness) under surface of the earth, but they contain all the mass effect under the observation point. Therefore, how to get accurate gravity and its gradient effect of the existing density structure (e.g. terrain) has been a key issue. Using the bathymetry data or ETOPO1 (http://www.ngdc.noaa.gov/mgg/global/global.html) model at a full resolution to calculate the terrain effect could spend too much computation time. We expect to develop an effective method that takes less time but can still yield the desired accuracy. In this study, a constant-density polyhedral model is used to calculate the gravity field and its vertical gradient, which is based on the work of Tsoulis (2012). According to gravity field attenuation with distance and variance of bathymetry, we present an adaptive mesh refinement and coarsening strategies to merge both global topography data and multi-beam bathymetry data. The local coarsening or size of mesh depends on user-defined accuracy and terrain variation (Davis et al., 2011). To depict terrain better, triangular surface element and rectangular surface element are used in fine and coarse mesh respectively. This strategy can also be applied to spherical coordinate in large region and global scale. Finally, we applied this method to calculate Bouguer gravity anomaly (BGA), mantle Bouguer anomaly(MBA) and their vertical gradient in SWIR. Further, we compared the result with previous results in the literature. Both synthetic model tests and field applications indicate that the adaptive terrain correction method can be adopted as a rapid and accurate tool of marine gravity data processing. References Davis, K. &Kass, M.A. & Li, Y., 2011. Rapid gravity and gravity gradiometry terrain corrections via an adaptive quadtree mesh discretization, EXPLOR GEOPHYS, 42, 88-97. Sandwell, D.T., Müller, R.D., Smith, W.H., Garcia, E. & Francis, R., 2014. New global marine gravity model from CryoSat-2 and Jason-1 reveals buried tectonic structure, SCIENCE, 346, 65-67. Tao, C., Li, H., Jin, X., Zhou, J., Wu, T., He, Y., Deng, X., Gu, C., Zhang, G. & Liu, W., 2014. Seafloor hydrothermal activity and polymetallic sulfide exploration on the southwest Indian ridge, CHINESE SCI BULL, 59, 2266-2276. Tsoulis, D., 2012. Analytical computation of the full gravity tensor of a homogeneous arbitrarily shaped polyhedral source using line integrals, GEOPHYSICS, 77, F1-F11.
Exercise Balikatan 2012 Technology Insertion Quicklook Report
2012-05-15
expanded polystyrene panels covered with a thin layer of cement, sand, fiberglass, and other additives. A permanent 200 sq ft building with windows... Expanded Polystyrene 1.5# density pre-cut panels and GFRC -Glass Fiber Reinforced Concrete Structural coating (Fiberglass Mesh, Portland Cement, Silica
Bashur, Chris A; Dahlgren, Linda A; Goldstein, Aaron S
2006-11-01
Engineered ligament tissues are promising materials for the repair of tears and ruptures, but require the development of biomaterial scaffolds that not only support physiologically relevant loads, but also possess architectures capable of orienting cell adhesion and extracellular matrix deposition. Based on evidence that micron-scale topographic features induce cell orientation through a contact guidance phenomenon, we postulate that oriented micron-scale fiber meshes-formed by the electrospinning process-can regulate cell morphology. To test this, fused fiber meshes of poly(d,l-lactic-co-glycolic acid) (PLGA) were electrospun onto rigid supports under conditions that produced mean fiber diameters of 0.14-3.6 microm, and angular standard deviations of 31-60 degrees . Analysis of the morphology of adherent NIH 3T3 fibroblasts indicated that projected cell area and aspect ratio increased systematically with both increasing fiber diameter and degree of fiber orientation. Importantly, cell morphology on 3.6 microm fibers was similar to that on spincoated PLGA films. Finally, cell densities on electrospun meshes were not significantly different from spincoated PLGA, indicating that cell proliferation is not sensitive to fiber diameter or orientation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popov, Emilian L.; Pointer, William David
This work assesses the influence of assumptions made when generating a mesh of a wire-wrappedgeometry. The contact region between a wire and its adjacent pin is commonly modeled by eitherembedding the wire to the adjacent pin or trimming the wire so that a gap separates the wire from itsadjacent pin. These models are referred to as close-gap and open-gap approaches herein and are applied totwo geometries. The first geometry consists of a single pin wire-wrapped subchannel. A polyhedral meshand a hexahedral mesh are generated. The second and third geometry are a 7-pin and a 19-pinwire-wrapped bundles meshed with polyhedral elementsmore » only. Pressure drops are obtained with theSTAR-CCM+computational fluid dynamic package. Sensitivity analyses of the mesh density, the meshtype, and the turbulent models are performed. Numerical results show that the best match to theexperimental data and to the Cheng-Todreas correlation is obtained with the combination of a hexahedralmesh, the shear stress transport (SST) turbulent model, and the open-gap approach. In the case of the 7-pingeometry, the best results are obtained with the open-gap approach and the SST turbulent model. The19-pin geometry yields contradictory results to the 7-pin geometry results, and thus will require furtherinvestigations.« less
Cosmology in one dimension: Vlasov dynamics.
Manfredi, Giovanni; Rouet, Jean-Louis; Miller, Bruce; Shiozawa, Yui
2016-04-01
Numerical simulations of self-gravitating systems are generally based on N-body codes, which solve the equations of motion of a large number of interacting particles. This approach suffers from poor statistical sampling in regions of low density. In contrast, Vlasov codes, by meshing the entire phase space, can reach higher accuracy irrespective of the density. Here, we perform one-dimensional Vlasov simulations of a long-standing cosmological problem, namely, the fractal properties of an expanding Einstein-de Sitter universe in Newtonian gravity. The N-body results are confirmed for high-density regions and extended to regions of low matter density, where the N-body approach usually fails.
Ultimate Strength of Ferro-Geopolymer Composite Built-Up I Joist
NASA Astrophysics Data System (ADS)
Vipin, K. T.; Ganesan, N.; Indira, P. V.
2017-07-01
An experimental study was carried out to study the behaviour of ferro-geopolymer built-up I- joist with different types of mesh reinforcements under flexure. Mesh reinforcements considered in this study are square welded meshes, square woven meshes and hexagonal meshes. First crack load as well as ultimate strength of ferro-geopolymer built-up I-joist in flexure was obtained. An attempt was made to predict the first crack load and ultimate moment capacity of the specimen.
Single chamber microbial fuel cell with spiral anode for dairy wastewater treatment.
Mardanpour, Mohammad Mahdi; Nasr Esfahany, Mohsen; Behzad, Tayebeh; Sedaqatvand, Ramin
2012-01-01
This study reports on the fabrication of a novel annular single chamber microbial fuel cell (ASCMFC) with spiral anode. The stainless steel mesh anode with graphite coating was used as anode. Dairy wastewater, containing complex organic matter, was used as substrate. ASCMFC had been operated for 450 h and results indicated a high open circuit voltage (about 810 mV) compared with previously published results. The maximum power density of 20.2 W/m(3) obtained in this study is significantly greater than the power densities reported in previous studies. Besides, a maximum coulombic efficiency of 26.87% with 91% COD removal was achieved. Good bacterial adhesion on the spiral anode is clearly shown in SEM micrographs. High power density and a successful performance in wastewater treatment in ASCMFC suggest it as a promising alternative to conventional MFCs for power generation and wastewater treatment. ASCMFC performance as a power generator was characterized based on polarization behavior and cell potentials. Copyright © 2012 Elsevier B.V. All rights reserved.
Predicting the dynamic fracture of steel via a non-local strain-energy density failure criterion.
DOT National Transportation Integrated Search
2014-06-01
Predicting the onset of fracture in a material subjected to dynamic loading conditions has typically been heavily mesh-dependent, and often must be specifically calibrated for each geometric design. This can lead to costly models and even : costlier ...
Matthews, Brent D; Pratt, Broc L; Pollinger, Harrison S; Backus, Charles L; Kercher, Kent W; Sing, R F; Heniford, B Todd
2003-10-01
The development of intra-abdominal adhesions, bowel obstruction, and enterocutaneous fistulas are potentially severe complications related to the intraperitoneal placement of prosthetic biomaterials. The purpose of this study was to determine the natural history of adhesion formation to polypropylene mesh and two types of polytetrafluoroethylene (ePTFE) mesh when placed intraperitoneally in a rabbit model that simulates laparoscopic ventral hernia repair. Thirty New Zealand white rabbits were used for this study. A 10-cm midline incision was performed for intra-abdominal access and a 2 cm x 2 cm piece of mesh (n = 60) was sewn to an intact peritoneum on each side of the midline. Two types of ePTFE mesh (Dual Mesh and modified Dual Mesh, W.L. Gore & Assoc., Flagstaff, AZ) and polypropylene mesh were compared. The rate of adhesion formation was evaluated by direct visualization using microlaparoscopy (2-mm endoscope/trocar) at 7 days, 3 weeks, 9 weeks, and 16 weeks after mesh implantation. Adhesions to the prosthetic mesh were scored for extent (%) using the Modified Diamond Scale (0 = 0%, 1
Assessment of Near-Field Sonic Boom Simulation Tools
NASA Technical Reports Server (NTRS)
Casper, J. H.; Cliff, S. E.; Thomas, S. D.; Park, M. A.; McMullen, M. S.; Melton, J. E.; Durston, D. A.
2008-01-01
A recent study for the Supersonics Project, within the National Aeronautics and Space Administration, has been conducted to assess current in-house capabilities for the prediction of near-field sonic boom. Such capabilities are required to simulate the highly nonlinear flow near an aircraft, wherein a sonic-boom signature is generated. There are many available computational fluid dynamics codes that could be used to provide the near-field flow for a sonic boom calculation. However, such codes have typically been developed for applications involving aerodynamic configuration, for which an efficiently generated computational mesh is usually not optimum for a sonic boom prediction. Preliminary guidelines are suggested to characterize a state-of-the-art sonic boom prediction methodology. The available simulation tools that are best suited to incorporate into that methodology are identified; preliminary test cases are presented in support of the selection. During this phase of process definition and tool selection, parallel research was conducted in an attempt to establish criteria that link the properties of a computational mesh to the accuracy of a sonic boom prediction. Such properties include sufficient grid density near shocks and within the zone of influence, which are achieved by adaptation and mesh refinement strategies. Prediction accuracy is validated by comparison with wind tunnel data.
Miao, Linli; Wang, Fang; Wang, Lu; Zou, Ting; Brochu, Gaétan; Guidoin, Robert
2015-01-01
Inguinal hernia repairs are among the most frequent operations performed worldwide. This study aims to provide further understanding of structural characteristics of hernia prostheses, and better comprehensive evaluation. Weight, porosity, pore size and other physical characteristics were evaluated; warp knitting structures were thoroughly discussed. Two methods referring to ISO 7198:1998, i.e., weight method and area method, were employed to calculate porosity. Porosity ranged from 37.3% to 69.7% measured by the area method, and 81.1% to 89.6% by the weight method. Devices with two-guide bar structures displayed both higher porosity (57.7%–69.7%) and effective porosity (30.8%–60.1%) than single-guide bar structure (37.3%–62.4% and 0%–5.9%, respectively). Filament diameter, stitch density and loop structure combined determined the thickness, weight and characteristics of pores. They must be well designed to avoid zero effective porosity regarding a single-bar structure. The area method was more effective in characterizing flat sheet meshes while the weight method was perhaps more accurate in describing stereoscopic void space for 3D structure devices. This article will give instructive clues for engineers to improve mesh structures, and better understanding of warp knitting meshes for surgeons. PMID:28793704
Medical subject heading (MeSH) annotations illuminate maize genetics and evolution
USDA-ARS?s Scientific Manuscript database
In the modern era, high-density marker panels and/or whole-genome sequencing,coupled with advanced phenotyping pipelines and sophisticated statistical methods, have dramatically increased our ability to generate lists of candidate genes or regions that are putatively associated with phenotypes or pr...
Orenstein, Sean B; Saberski, Ean R; Kreutzer, Donald L; Novitsky, Yuri W
2012-08-01
While synthetic prosthetics have essentially become mandatory for hernia repair, mesh-induced chronic inflammation and scarring can lead to chronic pain and limited mobility. Mesh propensity to induce such adverse effects is likely related to the prosthetic's material, weight, and/or pore size. We aimed to compare histopathologic responses to various synthetic meshes after short- and long-term implantations in mice. Samples of macroporous polyester (Parietex [PX]), heavyweight microporous polypropylene (Trelex[TX]), midweight microporous polypropylene (ProLite[PL]), lightweight macroporous polypropylene (Ultrapro[UP]), and expanded polytetrafluoroethylene (DualMesh[DM]) were implanted subcutaneously in mice. Four and 12 wk post-implantation, meshes were assessed for inflammation, foreign body reaction (FBR), and fibrosis. All meshes induced varying levels of inflammatory responses. PX induced the greatest inflammatory response and marked FBR. DM induced moderate FBR and a strong fibrotic response with mesh encapsulation at 12 wk. UP and PL had the lowest FBR, however, UP induced a significant chronic inflammatory response. Although inflammation decreased slightly for TX, marked FBR was present throughout the study. Of the three polypropylene meshes, fibrosis was greatest for TX and slightly reduced for PL and UP. For UP and PL, there was limited fibrosis within each mesh pore. Polyester mesh induced the greatest FBR and lasting chronic inflammatory response. Likewise, marked fibrosis and encapsulation was seen surrounding ePTFE. Heavier polypropylene meshes displayed greater early and persistent fibrosis; the reduced-weight polypropylene meshes were associated with the least amount of fibrosis. Mesh pore size was inversely proportional to bridging fibrosis. Moreover, reduced-weight polypropylene meshes demonstrated the smallest FBR throughout the study. Overall, we demonstrated that macroporous, reduced-weight polypropylene mesh exhibited the highest degree of biocompatibility at sites of mesh implantation. Copyright © 2012 Elsevier Inc. All rights reserved.
Changes in pelvic organ prolapse mesh mechanical properties following implantation in rats.
Ulrich, Daniela; Edwards, Sharon L; Alexander, David L J; Rosamilia, Anna; Werkmeister, Jerome A; Gargett, Caroline E; Letouzey, Vincent
2016-02-01
Pelvic organ prolapse (POP) is a multifactorial disease that manifests as the herniation of the pelvic organs into the vagina. Surgical methods for prolapse repair involve the use of a synthetic polypropylene mesh. The use of this mesh has led to significantly higher anatomical success rates compared with native tissue repairs, and therefore, despite recent warnings by the Food and Drug Administration regarding the use of vaginal mesh, the number of POP mesh surgeries has increased over the last few years. However, mesh implantation is associated with higher postsurgery complications, including pain and erosion, with higher consecutive rates of reoperation when placed vaginally. Little is known on how the mechanical properties of the implanted mesh itself change in vivo. It is assumed that the mechanical properties of these meshes remain unchanged, with any differences in mechanical properties of the formed mesh-tissue complex attributed to the attached tissue alone. It is likely that any changes in mesh mechanical properties that do occur in vivo will have an impact on the biomechanical properties of the formed mesh-tissue complex. The objective of the study was to assess changes in the multiaxial mechanical properties of synthetic clinical prolapse meshes implanted abdominally for up to 90 days, using a rat model. Another objective of the study was to assess the biomechanical properties of the formed mesh-tissue complex following implantation. Three nondegradable polypropylene clinical synthetic mesh types for prolapse repair (Gynemesh PS, Polyform Lite, and Restorelle) and a partially degradable polypropylene/polyglecaprone mesh (UltraPro) were mechanically assessed before and after implantation (n = 5/ mesh type) in Sprague Dawley rats for 30 (Gynemesh PS, Polyform Lite, and Restorelle) and 90 (UltraPro and Polyform Lite) days. Stiffness and permanent extension following cyclic loading, and breaking load, of the preimplanted mesh types, explanted mesh-tissue complexes, and explanted meshes were assessed using a multi-axial (ball-burst) method. The 4 clinical meshes varied from each other in weight, thickness, porosity, and pore size and showed significant differences in stiffness and breaking load before implantation. Following 30 days of implantation, the mechanical properties of some mesh types altered, with significant decreases in mesh stiffness and breaking load, and increased permanent extension. After 90 days these changes were more obvious, with significant decreases in stiffness and breaking load and increased permanent extension. Similar biomechanical properties of formed mesh-tissue complexes were observed for mesh types of different preimplant stiffness and structure after 90 days implantation. This is the first study to report on intrinsic changes in the mechanical properties of implanted meshes and how these changes have an impact on the estimated tissue contribution of the formed mesh-tissue complex. Decreased mesh stiffness, strength, and increased permanent extension following 90 days of implantation increase the biomechanical contribution of the attached tissue of the formed mesh-tissue complex more than previously thought. This needs to be considered when using meshes for prolapse repair. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Zhang, Xiaoyuan; Cheng, Shaoan; Liang, Peng; Huang, Xia; Logan, Bruce E
2011-01-01
The combined use of brush anodes and glass fiber (GF1) separators, and plastic mesh supporters were used here for the first time to create a scalable microbial fuel cell architecture. Separators prevented short circuiting of closely-spaced electrodes, and cathode supporters were used to avoid water gaps between the separator and cathode that can reduce power production. The maximum power density with a separator and supporter and a single cathode was 75 ± 1 W/m(3). Removing the separator decreased power by 8%. Adding a second cathode increased power to 154 ± 1 W/m(3). Current was increased by connecting two MFCs connected in parallel. These results show that brush anodes, combined with a glass fiber separator and a plastic mesh supporter, produce a useful MFC architecture that is inherently scalable due to good insulation between the electrodes and a compact architecture. Copyright © 2010 Elsevier Ltd. All rights reserved.
Computational Study of the Richtmyer-Meshkov Instability with a Complex Initial Condition
NASA Astrophysics Data System (ADS)
McFarland, Jacob; Reilly, David; Greenough, Jeffrey; Ranjan, Devesh
2014-11-01
Results are presented for a computational study of the Richtmyer-Meshkov instability with a complex initial condition. This study covers experiments which will be conducted at the newly-built inclined shock tube facility at the Georgia Institute of Technology. The complex initial condition employed consists of an underlying inclined interface perturbation with a broadband spectrum of modes superimposed. A three-dimensional staggered mesh arbitrary Lagrange Eulerian (ALE) hydrodynamics code developed at Lawerence Livermore National Laboratory called ARES was used to obtain both qualitative and quantitative results. Qualitative results are discussed using time series of density plots from which mixing width may be extracted. Quantitative results are also discussed using vorticity fields, circulation components, and energy spectra. The inclined interface case is compared to the complex interface case in order to study the effect of initial conditions on shocked, variable-density flows.
Chughtai, Bilal; Mao, Jialin; Buck, Jessica; Kaplan, Steven; Sedrakyan, Art
2015-06-02
To assess the use of mesh in pelvic organ prolapse surgery, and compare short term outcomes between procedures using and not using mesh. All inclusive, population based cohort study. Statewide surgical care captured in the New York Statewide Planning and Research Cooperative System. Women who underwent prolapse repair procedures in New York state from 2008 to 2011. 90 day safety events and reinterventions within one year, after propensity score matching. Categorical, time to event, and subgroup analyses (<65 and ≥ 65 year age groups) were conducted. Of 27,991 patients in total, 7338 and 20, 653 underwent prolapse repair procedures with and without mesh, respectively. Mesh use increased by 44.7%, from 1461 procedures in 2008 to 2114 procedures in 2011. Most patients in the cohort were younger than 65 years (62.3% (n=17,424/27, 991)). However, more patients were aged 65 years and older in the mesh group than in the non-mesh group (44.3% (n=3249) v 35.4% (n=7318)). Complications after surgery were not common, irrespective of the use or non-use of mesh. After propensity score matching, patients who received the surgery with mesh had a higher chance of having a reintervention within one year (mesh 3.3% v no mesh 2.2%, hazard ratio 1.47 (95% confidence interval 1.21 to 1.79)) and were more likely to have urinary retention within 90 days (mesh 7.5% v no mesh 5.6%, risk ratio 1.33 (95% confidence interval 1.18 to 1.51)), compared with those who received surgery without mesh. In subgroup analyses based on age, mesh use was associated with an increased risk of reintervention within one year in patients under age 65 years, and increased risk of urinary retention in patients aged 65 years and over. Despite multiple warnings released by the US Food and Drug Administration since 2008, use of mesh in pelvic organ prolapse surgery continues to grow. In this statewide comprehensive study, mesh procedures were associated with an increased risk of reinterventions within one year and urinary retention after surgery. © Chughtai et al 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sackett, S.J.
JASON solves general electrostatics problems having either slab or cylindrical symmetry. More specifically, it solves the self-adjoint elliptic equation, div . (KgradV) - ..gamma..V + rho = 0 in an aritrary two-dimensional domain. For electrostatics, V is the electrostatic potential, K is the dielectric tensor, and rho is the free-charge density. The parameter ..gamma.. is identically zero for electrostatics but may have a positive nonzero value in other cases (e.g., capillary surface problems with gravity loading). The system of algebraic equations used in JASON is generated by the finite element method. Four-node quadrilateral elements are used for most of themore » mesh. Triangular elements, however, are occasionally used on boundaries to avoid severe mesh distortions. 15 figures. (RWR)« less
NASA Astrophysics Data System (ADS)
Balsara, Dinshaw S.; Dumbser, Michael
2015-10-01
Several advances have been reported in the recent literature on divergence-free finite volume schemes for Magnetohydrodynamics (MHD). Almost all of these advances are restricted to structured meshes. To retain full geometric versatility, however, it is also very important to make analogous advances in divergence-free schemes for MHD on unstructured meshes. Such schemes utilize a staggered Yee-type mesh, where all hydrodynamic quantities (mass, momentum and energy density) are cell-centered, while the magnetic fields are face-centered and the electric fields, which are so useful for the time update of the magnetic field, are centered at the edges. Three important advances are brought together in this paper in order to make it possible to have high order accurate finite volume schemes for the MHD equations on unstructured meshes. First, it is shown that a divergence-free WENO reconstruction of the magnetic field can be developed for unstructured meshes in two and three space dimensions using a classical cell-centered WENO algorithm, without the need to do a WENO reconstruction for the magnetic field on the faces. This is achieved via a novel constrained L2-projection operator that is used in each time step as a postprocessor of the cell-centered WENO reconstruction so that the magnetic field becomes locally and globally divergence free. Second, it is shown that recently-developed genuinely multidimensional Riemann solvers (called MuSIC Riemann solvers) can be used on unstructured meshes to obtain a multidimensionally upwinded representation of the electric field at each edge. Third, the above two innovations work well together with a high order accurate one-step ADER time stepping strategy, which requires the divergence-free nonlinear WENO reconstruction procedure to be carried out only once per time step. The resulting divergence-free ADER-WENO schemes with MuSIC Riemann solvers give us an efficient and easily-implemented strategy for divergence-free MHD on unstructured meshes. Several stringent two- and three-dimensional problems are shown to work well with the methods presented here.
Current Density and Continuity in Discretized Models
ERIC Educational Resources Information Center
Boykin, Timothy B.; Luisier, Mathieu; Klimeck, Gerhard
2010-01-01
Discrete approaches have long been used in numerical modelling of physical systems in both research and teaching. Discrete versions of the Schrodinger equation employing either one or several basis functions per mesh point are often used by senior undergraduates and beginning graduate students in computational physics projects. In studying…
Spatial heterogeneity in the carrying capacity of sika deer in Japan.
Iijima, Hayato; Ueno, Mayumi
2016-06-09
Carrying capacity is 1 driver of wildlife population dynamics. Although in previous studies carrying capacity was considered to be a fixed entity, it may differ among locations due to environmental variation. The factors underlying variability in carrying capacity, however, have rarely been examined. Here, we investigated spatial heterogeneity in the carrying capacity of Japanese sika deer ( Cervus nippon ) from 2005 to 2014 in Yamanashi Prefecture, central Japan (mesh with grid cells of 5.5×4.6 km) by state-space modeling. Both carrying capacity and density dependence differed greatly among cells. Estimated carrying capacities ranged from 1.34 to 98.4 deer/km 2 . According to estimated population dynamics, grid cells with larger proportions of artificial grassland and deciduous forest were subject to lower density dependence and higher carrying capacity. We conclude that population dynamics of ungulates may vary spatially through spatial variation in carrying capacity and that the density level for controlling ungulate abundance should be based on the current density level relative to the carrying capacity for each area.
Forecasting Lightning Threat Using WRF Proxy Fields
NASA Technical Reports Server (NTRS)
McCaul, E. W., Jr.
2010-01-01
Objectives: Given that high-resolution WRF forecasts can capture the character of convective outbreaks, we seek to: 1. Create WRF forecasts of LTG threat (1-24 h), based on 2 proxy fields from explicitly simulated convection: - graupel flux near -15 C (captures LTG time variability) - vertically integrated ice (captures LTG threat area). 2. Calibrate each threat to yield accurate quantitative peak flash rate densities. 3. Also evaluate threats for areal coverage, time variability. 4. Blend threats to optimize results. 5. Examine sensitivity to model mesh, microphysics. Methods: 1. Use high-resolution 2-km WRF simulations to prognose convection for a diverse series of selected case studies. 2. Evaluate graupel fluxes; vertically integrated ice (VII). 3. Calibrate WRF LTG proxies using peak total LTG flash rate densities from NALMA; relationships look linear, with regression line passing through origin. 4. Truncate low threat values to make threat areal coverage match NALMA flash extent density obs. 5. Blend proxies to achieve optimal performance 6. Study CAPS 4-km ensembles to evaluate sensitivities.
Wang, Y T; Meheš, M M; Naseem, H-R; Ibrahim, M; Butt, M A; Ahmed, N; Wahab Bin Adam, M A; Issah, A-W; Mohammed, I; Goldstein, S D; Cartwright, K; Abdullah, F
2014-08-01
Inguinal hernia repair is the most common general surgery operation performed globally. However, the adoption of tension-free hernia repair with mesh has been limited in low-income settings, largely due to a lack of technical training and resources. The present study evaluates the impact of a 2-day training course instructing use of polypropylene mesh for inguinal hernia repair on the practice patterns of sub-Saharan African physicians. A surgical training course on tension-free mesh repair of hernias was provided to 16 physicians working in rural Ghanaian and Liberian hospitals. Three physicians were requested to prospectively record all their inguinal hernia surgeries, performed with or without mesh, during the 14-month period following the training. Demographic variables, diagnoses, and complications were collected by an independent data collector for mesh and non-mesh procedures. Surgery with mesh increased significantly following intervention, from near negligible levels prior to the training to 8.1 % of all inguinal hernia repairs afterwards. Mesh repair accounted for 90.8 % of recurrent hernia repairs and 2.9 % of primary hernia repairs after training. Overall complication rates between mesh and non-mesh procedures were not significantly different (p = 0.20). Three physicians who participated in an intensive education course were routinely using mesh for inguinal hernia repair 14 months after the training. This represents a significant change in practice pattern. Complication rates between patients who underwent inguinal hernia repairs with and without mesh were comparable. The present study provides evidence that short-term surgical training initiatives can have a substantial impact on local healthcare practice in resource-limited settings.
Superhydrophobic hierarchical structure carbon mesh films for oil/water separation application
NASA Astrophysics Data System (ADS)
Lu, Zhaoxia; Huang, Xing; Wang, Lisheng
2017-08-01
In this study, we showed that a superoleophobic mesh with the self-cleaning ability could be readily prepared by a facile spray-coating method on stainless steel mesh. Poly(methyl methacrylate) was employed to provide a stable strength between carbon nanotubes and steel mesh surface. The effect of opening size of these steel meshes on surface wetting has been investigated. The dynamics of liquid droplets was investigated as well. The as-prepared meshes exhibited both superhydrophobicity and superoleophilicity and could effectively separate water from the oil and water mixture. The present study contributes to the development of oil and water separation materials for marine industrial application.
NASA Astrophysics Data System (ADS)
Venkatachari, Balaji Shankar; Chang, Chau-Lyan
2016-11-01
The focus of this study is scale-resolving simulations of the canonical normal shock- isotropic turbulence interaction using unstructured tetrahedral meshes and the space-time conservation element solution element (CESE) method. Despite decades of development in unstructured mesh methods and its potential benefits of ease of mesh generation around complex geometries and mesh adaptation, direct numerical or large-eddy simulations of turbulent flows are predominantly carried out using structured hexahedral meshes. This is due to the lack of consistent multi-dimensional numerical formulations in conventional schemes for unstructured meshes that can resolve multiple physical scales and flow discontinuities simultaneously. The CESE method - due to its Riemann-solver-free shock capturing capabilities, non-dissipative baseline schemes, and flux conservation in time as well as space - has the potential to accurately simulate turbulent flows using tetrahedral meshes. As part of the study, various regimes of the shock-turbulence interaction (wrinkled and broken shock regimes) will be investigated along with a study on how adaptive refinement of tetrahedral meshes benefits this problem. The research funding for this paper has been provided by Revolutionary Computational Aerosciences (RCA) subproject under the NASA Transformative Aeronautics Concepts Program (TACP).
Mesh-based phase contrast Fourier transform imaging
NASA Astrophysics Data System (ADS)
Tahir, Sajjad; Bashir, Sajid; MacDonald, C. A.; Petruccelli, Jonathan C.
2017-04-01
Traditional x-ray radiography is limited by low attenuation contrast in materials of low electron density. Phase contrast imaging offers the potential to improve the contrast between such materials, but due to the requirements on the spatial coherence of the x-ray beam, practical implementation of such systems with tabletop (i.e. non-synchrotron) sources has been limited. One phase imaging technique employs multiple fine-pitched gratings. However, the strict manufacturing tolerances and precise alignment requirements have limited the widespread adoption of grating-based techniques. In this work, we have investigated a recently developed technique that utilizes a single grid of much coarser pitch. Our system consisted of a low power 100 μm spot Mo source, a CCD with 22 μm pixel pitch, and either a focused mammography linear grid or a stainless steel woven mesh. Phase is extracted from a single image by windowing and comparing data localized about harmonics of the mesh in the Fourier domain. The effects on the diffraction phase contrast and scattering amplitude images of varying grid types and periods, and of varying the width of the window function used to separate the harmonics were investigated. Using the wire mesh, derivatives of the phase along two orthogonal directions were obtained and combined to form improved phase contrast images.
Evaluation on Compressive Characteristics of Medical Stents Applied by Mesh Structures
NASA Astrophysics Data System (ADS)
Hirayama, Kazuki; He, Jianmei
2017-11-01
There are concerns about strength reduction and fatigue fracture due to stress concentration in currently used medical stents. To address these problems, meshed stents applied by mesh structures were interested for achieving long life and high strength perfromance of medical stents. The purpose of this study is to design basic mesh shapes to obatin three dimensional (3D) meshed stent models for mechanical property evaluation. The influence of introduced design variables on compressive characteristics of meshed stent models are evaluated through finite element analysis using ANSYS Workbench code. From the analytical results, the compressive stiffness are changed periodically with compressive directions, average results need to be introduced as the mean value of compressive stiffness of meshed stents. Secondly, compressive flexibility of meshed stents can be improved by increasing the angle proportional to the arm length of the mesh basic shape. By increasing the number of basic mesh shapes arranged in stent’s circumferential direction, compressive rigidity of meshed stent tends to be increased. Finaly reducing the mesh line width is found effective to improve compressive flexibility of meshed stents.
Chughtai, Bilal; Barber, Matthew D; Mao, Jialin; Forde, James C; Normand, Sharon-Lise T; Sedrakyan, Art
2017-03-01
Mesh, a synthetic graft, has been used in pelvic organ prolapse (POP) repair and stress urinary incontinence (SUI) to augment and strengthen weakened tissue. Polypropylene mesh has come under scrutiny by the US Food and Drug Administration. To examine the rates of mesh complications and invasive reintervention after the placement of vaginal mesh for POP repair or SUI surgery. This investigation was an observational cohort study at inpatient and ambulatory surgery settings in New York State. Participants were women who underwent transvaginal repair for POP or SUI with mesh between January 1, 2008, and December 31, 2012, and were followed up through December 31, 2013. They were divided into the following 4 groups based on the amount of mesh exposure: transvaginal POP repair surgery with mesh and concurrent sling use (vaginal mesh plus sling group), transvaginal POP repair with mesh and no concurrent sling use (vaginal mesh group), transvaginal POP repair without mesh but concurrent sling use for SUI (POP sling group), and sling for SUI alone (SUI sling group). The primary outcome was the occurrence of mesh complications and repeated invasive intervention within 1 year after the initial mesh implantation. A time-to-event analysis was performed to examine the occurrence of mesh erosions and subsequent reintervention. Secondary analyses of an age association (<65 vs ≥65 years) were conducted. The study identified 41 604 women who underwent 1 of the 4 procedures. The mean (SD) age of women at their initial mesh implantation was 56.2 (13.0) years. The highest risk of erosions was found in the vaginal mesh plus sling group (2.72%; 95% CI, 2.31%-3.21%) and the lowest in the SUI sling group (1.57%; 95% CI, 1.41%-1.74%). The risk of repeated surgery with concomitant erosion diagnosis was also the highest in the vaginal mesh plus sling group (2.13%; 95% CI, 1.76%-2.56%) and the lowest in the SUI sling group (1.16%; 95% CI, 1.03%-1.31%). The combined use of POP mesh and SUI mesh sling was associated with the highest erosion and repeated intervention risk, while mesh sling alone had the lowest erosion and repeated intervention risk. There is evidence for a dose-response relationship between the amount of mesh used and subsequent mesh erosions, complications, and invasive repeated intervention.
Wireless Sensor Networks - Node Localization for Various Industry Problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Derr, Kurt; Manic, Milos
Fast, effective monitoring following airborne releases of toxic substances is critical to mitigate risks to threatened population areas. Wireless sensor nodes at fixed predetermined locations may monitor such airborne releases and provide early warnings to the public. A challenging algorithmic problem is determining the locations to place these sensor nodes while meeting several criteria: 1) provide complete coverage of the domain, and 2) create a topology with problem dependent node densities, while 3) minimizing the number of sensor nodes. This manuscript presents a novel approach to determining optimal sensor placement, Advancing Front mEsh generation with Constrained dElaunay Triangulation and Smoothingmore » (AFECETS) that addresses these criteria. A unique aspect of AFECETS is the ability to determine wireless sensor node locations for areas of high interest (hospitals, schools, high population density areas) that require higher density of nodes for monitoring environmental conditions, a feature that is difficult to find in other research work. The AFECETS algorithm was tested on several arbitrary shaped domains. AFECETS simulation results show that the algorithm 1) provides significant reduction in the number of nodes, in some cases over 40%, compared to an advancing front mesh generation algorithm, 2) maintains and improves optimal spacing between nodes, and 3) produces simulation run times suitable for real-time applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gleicher, Frederick N.; Williamson, Richard L.; Ortensi, Javier
The MOOSE neutron transport application RATTLESNAKE was coupled to the fuels performance application BISON to provide a higher fidelity tool for fuel performance simulation. This project is motivated by the desire to couple a high fidelity core analysis program (based on the self-adjoint angular flux equations) to a high fidelity fuel performance program, both of which can simulate on unstructured meshes. RATTLESNAKE solves self-adjoint angular flux transport equation and provides a sub-pin level resolution of the multigroup neutron flux with resonance treatment during burnup or a fast transient. BISON solves the coupled thermomechanical equations for the fuel on a sub-millimetermore » scale. Both applications are able to solve their respective systems on aligned and unaligned unstructured finite element meshes. The power density and local burnup was transferred from RATTLESNAKE to BISON with the MOOSE Multiapp transfer system. Multiple depletion cases were run with one-way data transfer from RATTLESNAKE to BISON. The eigenvalues are shown to agree well with values obtained from the lattice physics code DRAGON. The one-way data transfer of power density is shown to agree with the power density obtained from an internal Lassman-style model in BISON.« less
Wireless Sensor Networks - Node Localization for Various Industry Problems
Derr, Kurt; Manic, Milos
2015-06-01
Fast, effective monitoring following airborne releases of toxic substances is critical to mitigate risks to threatened population areas. Wireless sensor nodes at fixed predetermined locations may monitor such airborne releases and provide early warnings to the public. A challenging algorithmic problem is determining the locations to place these sensor nodes while meeting several criteria: 1) provide complete coverage of the domain, and 2) create a topology with problem dependent node densities, while 3) minimizing the number of sensor nodes. This manuscript presents a novel approach to determining optimal sensor placement, Advancing Front mEsh generation with Constrained dElaunay Triangulation and Smoothingmore » (AFECETS) that addresses these criteria. A unique aspect of AFECETS is the ability to determine wireless sensor node locations for areas of high interest (hospitals, schools, high population density areas) that require higher density of nodes for monitoring environmental conditions, a feature that is difficult to find in other research work. The AFECETS algorithm was tested on several arbitrary shaped domains. AFECETS simulation results show that the algorithm 1) provides significant reduction in the number of nodes, in some cases over 40%, compared to an advancing front mesh generation algorithm, 2) maintains and improves optimal spacing between nodes, and 3) produces simulation run times suitable for real-time applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Straub, AP; Yip, NY; Elimelech, M
2014-01-01
Pressure-retarded osmosis (PRO) has the potential to generate sustainable energy from salinity gradients. PRO is typically considered for operation with river water and seawater, but a far greater energy of mixing can be harnessed from hypersaline solutions. This study investigates the power density that can be obtained in PRO from such concentrated solutions. Thin-film composite membranes with an embedded woven mesh were supported by tricot fabric feed spacers in a specially designed crossflow cell to maximize the operating pressure of the system, reaching a stable applied hydraulic pressure of 48 bar (700 psi) for more than 10 h. Operation atmore » this increased hydraulic pressure allowed unprecedented power densities, up to 60 W/m(2) with a 3 M (180 g/L) NaCl draw solution. Experimental power densities demonstrate reasonable agreement with power densities modeled using measured membrane properties, indicating high-pressure operation does not drastically alter membrane performance. Our findings exhibit the promise of the generation of power from high-pressure PRO with concentrated solutions.« less
Which drugs are risk factors for the development of gastroesophageal reflux disease?
Mungan, Zeynel; Pınarbaşı Şimşek, Binnur
2017-12-01
Gastroesophageal reflux disease (GERD), which is common in many communities, is associated with structural factors, eating habits, and the use of certain drugs. The use of such drugs can lead to the emergence of GERD and can also exacerbate existing reflux symptoms. These drugs can contribute to GERD by directly causing mucosal damage, by reducing lower esophageal sphincter pressure (LESP), or by affecting esophagogastric motility. In this article, we report our investigation of the relationships between GERD and medications within the scope of the "Turkish GERD Consensus Group." For the medication groups for which sufficient data were obtained (Figure 1), a systematic literature review in English was conducted using the keywords "gastroesophageal reflux" [MeSH Terms] and "anti-inflammatory agents, non-steroidal" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "acetylsalicylic acid" [MeSH Terms], "gastroesophageal reflux" [All Fields] and "estrogenic agents" [All Fields], "gastroesophageal reflux" [All Fields] and "progesterones" [All Fields], "gastroesophageal reflux" [All Fields] and "hormone replacement therapy" [All Fields], "gastroesophageal reflux" [MeSH Terms] and "diphosphonates" [MeSH Terms] OR "diphosphonates" [All Fields], "calcium channel blockers" [MeSH Terms] and "gastroesophageal reflux" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "nitrates" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "antidepressive agents" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "benzodiazepines" [MeSH Terms] and "hypnotic drugs" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "cholinergic antagonists" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "theophylline" [MeSH Terms], and "gastroesophageal reflux [MeSH Terms] AND "anti-asthmatic agents" [MeSH Terms]. The studies were analyzed and the results are presented here.
NASA Astrophysics Data System (ADS)
Davris, Theodoros; Lyulin, Alexey V.
2016-05-01
The significant drop of the storage modulus under uniaxial deformation (Payne effect) restrains the performance of the elastomer-based composites and the development of possible new applications. In this paper molecular-dynamics (MD) computer simulations using LAMMPS MD package have been performed to study the mechanical properties of a coarse-grained model of this family of nanocomposite materials. Our goal is to provide simulational insights into the viscoelastic properties of filled elastomers, and try to connect the macroscopic mechanics with composite microstructure, the strength of the polymer-filler interactions and the polymer mobility at different scales. To this end we simulate random copolymer films capped between two infinite solid (filler aggregate) walls. We systematically vary the strength of the polymer-substrate adhesion interactions, degree of polymer confinement (film thickness), polymer crosslinking density, and study their influence on the equilibrium and non-equilibrium structure, segmental dynamics, and the mechanical properties of the simulated systems. The glass-transition temperature increases once the mesh size became smaller than the chain radius of gyration; otherwise it remained invariant to mesh-size variations. This increase in the glass-transition temperature was accompanied by a monotonic slowing-down of segmental dynamics on all studied length scales. This observation is attributed to the correspondingly decreased width of the bulk density layer that was obtained in films whose thickness was larger than the end-to-end distance of the bulk polymer chains. To test this hypothesis additional simulations were performed in which the crystalline walls were replaced with amorphous or rough walls.
Koniges, Alice; Liu, Wangyi; Lidia, Steven; ...
2016-04-01
We explore the simulation challenges and requirements for experiments planned on facilities such as the NDCX-II ion accelerator at LBNL, currently undergoing commissioning. Hydrodynamic modeling of NDCX-II experiments include certain lower temperature effects, e.g., surface tension and target fragmentation, that are not generally present in extreme high-energy laser facility experiments, where targets are completely vaporized in an extremely short period of time. Target designs proposed for NDCX-II range from metal foils of order one micron thick (thin targets) to metallic foam targets several tens of microns thick (thick targets). These high-energy-density experiments allow for the study of fracture as wellmore » as the process of bubble and droplet formation. We incorporate these physics effects into a code called ALE-AMR that uses a combination of Arbitrary Lagrangian Eulerian hydrodynamics and Adaptive Mesh Refinement. Inclusion of certain effects becomes tricky as we must deal with non-orthogonal meshes of various levels of refinement in three dimensions. A surface tension model used for droplet dynamics is implemented in ALE-AMR using curvature calculated from volume fractions. Thick foam target experiments provide information on how ion beam induced shock waves couple into kinetic energy of fluid flow. Although NDCX-II is not fully commissioned, experiments are being conducted that explore material defect production and dynamics.« less
Preliminary SAGE Simulations of Volcanic Jets Into a Stratified Atmosphere
NASA Astrophysics Data System (ADS)
Peterson, A. H.; Wohletz, K. H.; Ogden, D. E.; Gisler, G. R.; Glatzmaier, G. A.
2007-12-01
The SAGE (SAIC Adaptive Grid Eulerian) code employs adaptive mesh refinement in solving Eulerian equations of complex fluid flow desirable for simulation of volcanic eruptions. The goal of modeling volcanic eruptions is to better develop a code's predictive capabilities in order to understand the dynamics that govern the overall behavior of real eruption columns. To achieve this goal, we focus on the dynamics of underexpended jets, one of the fundamental physical processes important to explosive eruptions. Previous simulations of laboratory jets modeled in cylindrical coordinates were benchmarked with simulations in CFDLib (Los Alamos National Laboratory), which solves the full Navier-Stokes equations (includes viscous stress tensor), and showed close agreement, indicating that adaptive mesh refinement used in SAGE may offset the need for explicit calculation of viscous dissipation.We compare gas density contours of these previous simulations with the same initial conditions in cylindrical and Cartesian geometries to laboratory experiments to determine both the validity of the model and the robustness of the code. The SAGE results in both geometries are within several percent of the experiments for position and density of the incident (intercepting) and reflected shocks, slip lines, shear layers, and Mach disk. To expand our study into a volcanic regime, we simulate large-scale jets in a stratified atmosphere to establish the code's ability to model a sustained jet into a stable atmosphere.
NASA Astrophysics Data System (ADS)
Kenamond, Mack; Bement, Matthew; Shashkov, Mikhail
2014-07-01
We present a new discretization for 2D arbitrary Lagrangian-Eulerian hydrodynamics in rz geometry (cylindrical coordinates) that is compatible, total energy conserving and symmetry preserving. In the first part of the paper, we describe the discretization of the basic Lagrangian hydrodynamics equations in axisymmetric 2D rz geometry on general polygonal meshes. It exactly preserves planar, cylindrical and spherical symmetry of the flow on meshes aligned with the flow. In particular, spherical symmetry is preserved on polar equiangular meshes. The discretization conserves total energy exactly up to machine round-off on any mesh. It has a consistent definition of kinetic energy in the zone that is exact for a velocity field with constant magnitude. The method for discretization of the Lagrangian equations is based on ideas presented in [2,3,7], where the authors use a special procedure to distribute zonal mass to corners of the zone (subzonal masses). The momentum equation is discretized in its “Cartesian” form with a special definition of “planar” masses (area-weighted). The principal contributions of this part of the paper are as follows: a definition of “planar” subzonal mass for nodes on the z axis (r=0) that does not require a special procedure for movement of these nodes; proof of conservation of the total energy; formulated for general polygonal meshes. We present numerical examples that demonstrate the robustness of the new method for Lagrangian equations on a variety of grids and test problems including polygonal meshes. In particular, we demonstrate the importance of conservation of total energy for correctly modeling shock waves. In the second part of the paper we describe the remapping stage of the arbitrary Lagrangian-Eulerian algorithm. The general idea is based on the following papers [25-28], where it was described for Cartesian coordinates. We describe a distribution-based algorithm for the definition of remapped subzonal densities and a local constrained-optimization-based approach for each zone to find the subzonal mass fluxes. In this paper we give a systematic and complete description of the algorithm for the axisymmetric case and provide justification for our approach. The ALE algorithm conserves total energy on arbitrary meshes and preserves symmetry when remapping from one equiangular polar mesh to another. The principal contributions of this part of the paper are the extension of this algorithm to general polygonal meshes and 2D rz geometry with requirement of symmetry preservation on special meshes. We present numerical examples that demonstrate the robustness of the new ALE method on a variety of grids and test problems including polygonal meshes and some realistic experiments. We confirm the importance of conservation of total energy for correctly modeling shock waves.
Does expanded polytetrafluoroethylene mesh really shrink after laparoscopic ventral hernia repair?
Carter, P R; LeBlanc, K A; Hausmann, M G; Whitaker, J M; Rhynes, V K; Kleinpeter, K P; Allain, B W
2012-06-01
The shrinkage of mesh has been cited as a possible explanation for hernia recurrence. Expanded polytetrafluoroethylene (ePTFE) is unique in that it can be visualized on computed tomography (CT). Some animal studies have shown a greater than 40% rate of contraction of ePTFE; however, very few human studies have been performed. A total of 815 laparoscopic incisional/ventral hernia (LIVH) repairs were performed by a single surgical group. DualMesh Plus (ePTFE) (WL Gore & Associates, Newark, DE) was placed in the majority of these patients using both transfascial sutures and tack fixation. Fifty-eight patients had postoperative CTs of the abdomen and pelvis with ePTFE and known transverse diameter of the implanted mesh. The prosthesis was measured on the CT using the AquariusNet software program (TeraRecon, San Mateo, CA), which outlines the mesh and calculates the total length. Data were collected regarding the original mesh size, known linear dimension of mesh, seroma formation, and time interval since mesh implantation in months. The mean shrinkage rate was 6.7%. The duration of implantation ranged from 6 weeks to 78 months, with a median of 15 months. Seroma was seen in 8.6% (5) of patients. No relationship was identified between the percentage of shrinkage and the original mesh size (P = 0.78), duration of time implanted (P = 0.57), or seroma formation (P = 0.074). In 27.5% (16) of patients, no shrinkage of mesh was identified. Of the patients who did experience mesh shrinkage, the range of shrinkage was 2.6-25%. Our results are markedly different from animal studies and show that ePTFE has minimal shrinkage after LIVH repair. The use of transfascial sutures in addition to tack fixation may have an implication on the mesh contraction rates.
MRI Evaluation of an Elastic TPU Mesh under Pneumoperitoneum in IPOM Position in a Porcine Model.
Lambertz, A; van den Hil, L C L; Ciritsis, A; Eickhoff, R; Kraemer, N A; Bouvy, N D; Müllen, A; Klinge, U; Neumann, U P; Klink, C D
2018-06-01
The frequency of laparoscopic approaches increased in hernia surgery over the past years. After mesh placement in IPOM position, the real extent of the meshes configurational changes after termination of pneumoperitoneum is still largely unknown. To prevent a later mesh folding it might be useful to place the mesh while it is kept under tension. Conventionally used meshes may lose their Effective Porosity under these conditions due to poor elastic properties. The aim of this study was to evaluate a newly developed elastic thermoplastic polyurethane (TPU) containing mesh that retains its Effective Porosity under mechanical strain in IPOM position in a porcine model. It was visualized under pneumoperitoneum using MRI in comparison to polyvinylidenefluoride (PVDF) meshes with similar structure. In each of ten minipigs, a mesh (TPU containing or native PVDF, 10 × 20 cm) was randomly placed in IPOM position at the center of the abdominal wall. After 8 weeks, six pigs underwent MRI evaluation with and without pneumoperitoneum to assess the visibility and elasticity of the mesh. Finally, pigs were euthanized and abdominal walls were explanted for histological and immunohistochemical assessment. The degree of adhesion formation was documented. Laparoscopic implantation of elastic TPU meshes in IPOM position was feasible and safe in a minipig model. Mesh position could be precisely visualized and assessed with and without pneumoperitoneum using MRI after 8 weeks. Elastic TPU meshes showed a significantly higher surface increase under pneumoperitoneum in comparison to PVDF. Immunohistochemically, the amount of CD45-positive cells was significantly lower and the Collagen I/III ratio was significantly higher in TPU meshes after 8 weeks. There were no differences regarding adhesion formation between study groups. The TPU mesh preserves its elastic properties in IPOM position in a porcine model after 8 weeks. Immunohistochemistry indicates superior biocompatibility regarding CD45-positive cells and Collagen I/III ratio in comparison to PVDF meshes with a similar structure.
NASA Astrophysics Data System (ADS)
Seddik, H.; Greve, R.; Zwinger, T.; Gillet-Chaulet, F.; Gagliardini, O.
2010-12-01
A three-dimensional, thermo-mechanically coupled model is applied to the Greenland ice sheet. The model implements the full-Stokes equations for the ice dynamics, and the system is solved with the finite-element method (FEM) using the open source multi-physics package Elmer (http://www.csc.fi/elmer/). The finite-element mesh for the computational domain has been created using the Greenland surface and bedrock DEM data with a spatial resolution of 5 km (SeaRise community effort, based on Bamber and others, 2001). The study is particularly aimed at better understanding the ice dynamics near the major Greenland ice streams. The meshing procedure starts with the bedrock footprint where a mesh with triangle elements and a resolution of 5 km is constructed. Since the resulting mesh is unnecessarily dense in areas with slow ice dynamics, an anisotropic mesh adaptation procedure has been introduced. Using the measured surface velocities to evaluate the Hessian matrix of the velocities, a metric tensor is computed at the mesh vertices in order to define the adaptation scheme. The resulting meshed footprint obtained with the automatic tool YAMS shows a high density of elements in the vicinities of the North-East Greenland Ice Stream (NEGIS), the Jakobshavn ice stream (JIS) and the Kangerdlugssuaq (KL) and Helheim (HH) glaciers. On the other hand, elements with a coarser resolution are generated away from the ice streams and domain margins. The final three-dimensional mesh is obtained by extruding the 2D footprint with 21 vertical layers, so that the resulting mesh contains 400860 wedge elements and 233583 nodes. The numerical solution of the Stokes and the heat transfer equations involves direct and iterative solvers depending on the simulation case, and both methods are coupled with stabilization procedures. The boundary conditions are such that the temperature at the surface uses the present-day mean annual air temperature given by a parameterization or directly from the available data, the geothermal heat flux at the bedrock is prescribed as spatially constant and the lateral sides are open boundaries. A non-linear Weertman law is used for the basal sliding. The project goal is to better assess the effects of dynamical changes of the Greenland ice sheet on sea level rise under global-warming conditions. Hence, the simulations have been conducted in order to investigate the ice sheet evolution using the climate forcing experiments defined in the SeaRISE project. For that purpose, four different experiments have been conducted, (i) constant climate control run beginning at present (epoch 2004-1-1 0:0:0) and running up to 500 years holding the climate constant to its present state, (ii) constant climate forcing with increased basal lubrication, (iii) AR4 climate run forced by anomalies derived from results given in the IPCC 4th Assessment Report (AR4) for the A1B emission scenario, (iv) AR4 climate run with increased basal lubrication.
Properties of bio-based medium density fiberboard
Sangyeob Lee; Todd F. Shupe; Chung Y. Hse
2006-01-01
In order to utilize agricultural waste fibers as an alternative resource for composites, a number of variables were investigated to determine whether the mechanical and physical properties of agro-based fiberboard could be improved. Fibers were classified into four different mesh sizes and used to evaluated the effect of fiber size on the mechanical and physical...
NASA Technical Reports Server (NTRS)
Anderson, John R.; Wilbur, Paul J.
1989-01-01
The potential usefulness of the constrained sheath optics concept as a means of controlling the divergence of low energy, high current density ion beams is examined numerically and experimentally. Numerical results demonstrate that some control of the divergence of typical ion beamlets can be achieved at perveance levels of interest by contouring the surface of the constrained sheath properly. Experimental results demonstrate that a sheath can be constrained by a wire mesh attached to the screen plate of the ion optics system. The numerically predicted beamlet divergence characteristics are shown to depart from those measured experimentally, and additional numerical analysis is used to demonstrate that this departure is probably due to distortions of the sheath caused by the fact that it attempts to conform to the individual wires that make up the sheath constraining mesh. The concept is considered potentially useful in controlling the divergence of ion beamlets in applications where low divergence, low energy, high current density beamlets are being sought, but more work is required to demonstrate this for net beam ion energies as low as 5 eV.
First principles calculation of thermo-mechanical properties of thoria using Quantum ESPRESSO
NASA Astrophysics Data System (ADS)
Malakkal, Linu; Szpunar, Barbara; Zuniga, Juan Carlos; Siripurapu, Ravi Kiran; Szpunar, Jerzy A.
2016-05-01
In this work, we have used Quantum ESPRESSO (QE), an open source first principles code, based on density-functional theory, plane waves, and pseudopotentials, along with quasi-harmonic approximation (QHA) to calculate the thermo-mechanical properties of thorium dioxide (ThO2). Using Python programming language, our group developed qe-nipy-advanced, an interface to QE, which can evaluate the structural and thermo-mechanical properties of materials. We predicted the phonon contribution to thermal conductivity (kL) using the Slack model. We performed the calculations within local density approximation (LDA) and generalized gradient approximation (GGA) with the recently proposed version for solids (PBEsol). We employed a Monkhorst-Pack 5 × 5 × 5 k-points mesh in reciprocal space with a plane wave cut-off energy of 150 Ry to obtain the convergence of the structure. We calculated the dynamical matrices of the lattice on a 4 × 4 × 4 mesh. We have predicted the heat capacity, thermal expansion and the phonon contribution to thermal conductivity, as a function of temperature up to 1400K, and compared them with the previous work and known experimental results.
Combined in vivo and ex vivo analysis of mesh mechanics in a porcine hernia model.
Kahan, Lindsey G; Lake, Spencer P; McAllister, Jared M; Tan, Wen Hui; Yu, Jennifer; Thompson, Dominic; Brunt, L Michael; Blatnik, Jeffrey A
2018-02-01
Hernia meshes exhibit variability in mechanical properties, and their mechanical match to tissue has not been comprehensively studied. We used an innovative imaging model of in vivo strain tracking and ex vivo mechanical analysis to assess effects of mesh properties on repaired abdominal walls in a porcine model. We hypothesized that meshes with dissimilar mechanical properties compared to native tissue would alter abdominal wall mechanics more than better-matched meshes. Seven mini-pigs underwent ventral hernia creation and subsequent open repair with one of two heavyweight polypropylene meshes. Following mesh implantation with attached radio-opaque beads, fluoroscopic images were taken at insufflation pressures from 5 to 30 mmHg on postoperative days 0, 7, and 28. At 28 days, animals were euthanized and ex vivo mechanical testing performed on full-thickness samples across repaired abdominal walls. Testing was conducted on 13 mini-pig controls, and on meshes separately. Stiffness and anisotropy (the ratio of stiffness in the transverse versus craniocaudal directions) were assessed. 3D reconstructions of repaired abdominal walls showed stretch patterns. As pressure increased, both meshes expanded, with no differences between groups. Over time, meshes contracted 17.65% (Mesh A) and 0.12% (Mesh B; p = 0.06). Mesh mechanics showed that Mesh A deviated from anisotropic native tissue more than Mesh B. Compared to native tissue, Mesh A was stiffer both transversely and craniocaudally. Explanted repaired abdominal walls of both treatment groups were stiffer than native tissue. Repaired tissue became less anisotropic over time, as mesh properties prevailed over native abdominal wall properties. This technique assessed 3D stretch at the mesh level in vivo in a porcine model. While the abdominal wall expanded, mesh-ingrown areas contracted, potentially indicating stresses at mesh edges. Ex vivo mechanics demonstrate that repaired tissue adopts mesh properties, suggesting that a better-matched mesh could reduce changes to abdominal wall mechanics.
Rieder, Erwin; Stoiber, Martin; Scheikl, Verena; Poglitsch, Marcus; Dal Borgo, Andrea; Prager, Gerhard; Schima, Heinrich
2011-01-01
Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks. Copyright © 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
No Flares from Gamma-Ray Burst Afterglow Blast Waves Encountering Sudden Circumburst Density Change
NASA Astrophysics Data System (ADS)
Gat, Ilana; van Eerten, Hendrik; MacFadyen, Andrew
2013-08-01
Afterglows of gamma-ray bursts are observed to produce light curves with the flux following power-law evolution in time. However, recent observations reveal bright flares at times on the order of minutes to days. One proposed explanation for these flares is the interaction of a relativistic blast wave with a circumburst density transition. In this paper, we model this type of interaction computationally in one and two dimensions, using a relativistic hydrodynamics code with adaptive mesh refinement called RAM, and analytically in one dimension. We simulate a blast wave traveling in a stellar wind environment that encounters a sudden change in density, followed by a homogeneous medium, and compute the observed radiation using a synchrotron model. We show that flares are not observable for an encounter with a sudden density increase, such as a wind termination shock, nor for an encounter with a sudden density decrease. Furthermore, by extending our analysis to two dimensions, we are able to resolve the spreading, collimation, and edge effects of the blast wave as it encounters the change in circumburst medium. In all cases considered in this paper, we find that a flare will not be observed for any of the density changes studied.
Patterning of polymer nanofiber meshes by electrospinning for biomedical applications
Neves, Nuno M; Campos, Rui; Pedro, Adriano; Cunha, José; Macedo, Francisco; Reis, Rui L
2007-01-01
The end-product of the electrospinning process is typically a randomly aligned fiber mesh or membrane. This is a result of the electric field generated between the drop of polymer solution at the needle and the collector. The developed electric field causes the stretching of the fibers and their random deposition. By judicious selection of the collector architecture, it is thus possible to develop other morphologies on the nanofiber meshes. The aim of this work is to prepare fiber meshes using various patterned collectors with specific dimensions and designs and to evaluate how those patterns can affect the properties of the meshes relevant to biomedical applications. This study aims at verifying whether it is possible to control the architecture of the fiber meshes by tailoring the geometry of the collector. Three different metallic collector topographies are used to test this hypothesis. Electrospun nonwoven patterned meshes of polyethylene oxide (PEO) and poly(ε-capro-lactone) (PCL) were successfully prepared. Those fiber meshes were analyzed by scanning electron microscopy (SEM). Both mechanical properties of the meshes and cell contacting experiments were performed to test the effect of the produced patterns over the properties of the meshes relevant for biomedical applications. The present study will evaluate cell adhesion sensitivity to the patterns generated and the effect of those patterns on the tensile properties of the fiber meshes. PMID:18019842
A New Method for Reduction of Photomultiplier Signal-Induced Noise
NASA Technical Reports Server (NTRS)
Koble, Andrea; DeYoung, Russell
2000-01-01
For lidar measurements of ozone, photomultiplier tube (PMT) detector signal-induced noise represents a fundamental problem that complicates the extraction of information from lidar data. A new method is developed to significantly reduce signal-induced noise in lidar receiver PMT detectors. The electron optics of the lidar photomultiplier detector is modified to filter the source of signal-induced noise. A mesh electrode external to the PMT is utilized to control photoemission and disorient electron trajectories from the photocathode to the first dynode. Experiments were taken both with simulated and actual lidar return signals at Langley Research Center. Results show at least 40 percent more accurate ozone number density values with a mesh voltage of 60 V applied than with no voltage applied.
The Analysis of Adhesively Bonded Advanced Composite Joints Using Joint Finite Elements
NASA Technical Reports Server (NTRS)
Stapleton, Scott E.; Waas, Anthony M.
2012-01-01
The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various joint configurations, including double cantilever beam and single lap joints.
Implementation of tetrahedral-mesh geometry in Monte Carlo radiation transport code PHITS
NASA Astrophysics Data System (ADS)
Furuta, Takuya; Sato, Tatsuhiko; Han, Min Cheol; Yeom, Yeon Soo; Kim, Chan Hyeong; Brown, Justin L.; Bolch, Wesley E.
2017-06-01
A new function to treat tetrahedral-mesh geometry was implemented in the particle and heavy ion transport code systems. To accelerate the computational speed in the transport process, an original algorithm was introduced to initially prepare decomposition maps for the container box of the tetrahedral-mesh geometry. The computational performance was tested by conducting radiation transport simulations of 100 MeV protons and 1 MeV photons in a water phantom represented by tetrahedral mesh. The simulation was repeated with varying number of meshes and the required computational times were then compared with those of the conventional voxel representation. Our results show that the computational costs for each boundary crossing of the region mesh are essentially equivalent for both representations. This study suggests that the tetrahedral-mesh representation offers not only a flexible description of the transport geometry but also improvement of computational efficiency for the radiation transport. Due to the adaptability of tetrahedrons in both size and shape, dosimetrically equivalent objects can be represented by tetrahedrons with a much fewer number of meshes as compared its voxelized representation. Our study additionally included dosimetric calculations using a computational human phantom. A significant acceleration of the computational speed, about 4 times, was confirmed by the adoption of a tetrahedral mesh over the traditional voxel mesh geometry.
Implementation of tetrahedral-mesh geometry in Monte Carlo radiation transport code PHITS.
Furuta, Takuya; Sato, Tatsuhiko; Han, Min Cheol; Yeom, Yeon Soo; Kim, Chan Hyeong; Brown, Justin L; Bolch, Wesley E
2017-06-21
A new function to treat tetrahedral-mesh geometry was implemented in the particle and heavy ion transport code systems. To accelerate the computational speed in the transport process, an original algorithm was introduced to initially prepare decomposition maps for the container box of the tetrahedral-mesh geometry. The computational performance was tested by conducting radiation transport simulations of 100 MeV protons and 1 MeV photons in a water phantom represented by tetrahedral mesh. The simulation was repeated with varying number of meshes and the required computational times were then compared with those of the conventional voxel representation. Our results show that the computational costs for each boundary crossing of the region mesh are essentially equivalent for both representations. This study suggests that the tetrahedral-mesh representation offers not only a flexible description of the transport geometry but also improvement of computational efficiency for the radiation transport. Due to the adaptability of tetrahedrons in both size and shape, dosimetrically equivalent objects can be represented by tetrahedrons with a much fewer number of meshes as compared its voxelized representation. Our study additionally included dosimetric calculations using a computational human phantom. A significant acceleration of the computational speed, about 4 times, was confirmed by the adoption of a tetrahedral mesh over the traditional voxel mesh geometry.
Evans, Alistair R.; McHenry, Colin R.
2015-01-01
The reliability of finite element analysis (FEA) in biomechanical investigations depends upon understanding the influence of model assumptions. In producing finite element models, surface mesh resolution is influenced by the resolution of input geometry, and influences the resolution of the ensuing solid mesh used for numerical analysis. Despite a large number of studies incorporating sensitivity studies of the effects of solid mesh resolution there has not yet been any investigation into the effect of surface mesh resolution upon results in a comparative context. Here we use a dataset of crocodile crania to examine the effects of surface resolution on FEA results in a comparative context. Seven high-resolution surface meshes were each down-sampled to varying degrees while keeping the resulting number of solid elements constant. These models were then subjected to bite and shake load cases using finite element analysis. The results show that incremental decreases in surface resolution can result in fluctuations in strain magnitudes, but that it is possible to obtain stable results using lower resolution surface in a comparative FEA study. As surface mesh resolution links input geometry with the resulting solid mesh, the implication of these results is that low resolution input geometry and solid meshes may provide valid results in a comparative context. PMID:26056620
NASA Technical Reports Server (NTRS)
Rafferty, Connor S.; Biegel, Bryan A.; Yu, Zhi-Ping; Ancona, Mario G.; Bude, J.; Dutton, Robert W.; Saini, Subhash (Technical Monitor)
1998-01-01
A density-gradient (DG) model is used to calculate quantum-mechanical corrections to classical carrier transport in MOS (Metal Oxide Semiconductor) inversion/accumulation layers. The model is compared to measured data and to a fully self-consistent coupled Schrodinger and Poisson equation (SCSP) solver. Good agreement is demonstrated for MOS capacitors with gate oxide as thin as 21 A. It is then applied to study carrier distribution in ultra short MOSFETs (Metal Oxide Semiconductor Field Effect Transistor) with surface roughness. This work represents the first implementation of the DG formulation on multidimensional unstructured meshes. It was enabled by a powerful scripting approach which provides an easy-to-use and flexible framework for solving the fourth-order PDEs (Partial Differential Equation) of the DG model.
NASA Astrophysics Data System (ADS)
Zuo, S.; Dai, S.; Ren, Y.; Yu, Z.
2017-12-01
Scientifically revealing the spatial heterogeneity and the relationship between the fragmentation of urban landscape and the direct carbon emissions are of great significance to land management and urban planning. In fact, the linear and nonlinear effects among the various factors resulted in the carbon emission spatial map. However, there is lack of the studies on the direct and indirect relations between the carbon emission and the city functional spatial form changes, which could not be reflected by the land use change. The linear strength and direction of the single factor could be calculated through the correlation and Geographically Weighted Regression (GWR) analysis, the nonlinear power of one factor and the interaction power of each two factors could be quantified by the Geodetector analysis. Therefore, we compared the landscape fragmentation metrics of the urban land cover and functional district patches to characterize the landscape form and then revealed the relations between the landscape fragmentation level and the direct the carbon emissions based on the three methods. The results showed that fragmentation decreased and the fragmented patches clustered at the coarser resolution. The direct CO2 emission density and the population density increased when the fragmentation level aggregated. The correlation analysis indicated the weak linear relation between them. The spatial variation of GWR output indicated the fragmentation indicator (MESH) had the positive influence on the carbon emission located in the relatively high emission region, and the negative effects regions accounted for the small part of the area. The Geodetector which explores the nonlinear relation identified the DIVISION and MESH as the most powerful direct factor for the land cover patches, NP and PD for the functional district patches, and the interactions between fragmentation indicator (MESH) and urban sprawl metrics (PUA and DIS) had the greatly increased explanation powers on the urban carbon emission. Overall, this study provides a framework to understand the relation between the urban landscape fragmentation and the carbon emission for the low carbon city construction planning in the other cities.
Morphology and linear-elastic moduli of random network solids.
Nachtrab, Susan; Kapfer, Sebastian C; Arns, Christoph H; Madadi, Mahyar; Mecke, Klaus; Schröder-Turk, Gerd E
2011-06-17
The effective linear-elastic moduli of disordered network solids are analyzed by voxel-based finite element calculations. We analyze network solids given by Poisson-Voronoi processes and by the structure of collagen fiber networks imaged by confocal microscopy. The solid volume fraction ϕ is varied by adjusting the fiber radius, while keeping the structural mesh or pore size of the underlying network fixed. For intermediate ϕ, the bulk and shear modulus are approximated by empirical power-laws K(phi)proptophin and G(phi)proptophim with n≈1.4 and m≈1.7. The exponents for the collagen and the Poisson-Voronoi network solids are similar, and are close to the values n=1.22 and m=2.11 found in a previous voxel-based finite element study of Poisson-Voronoi systems with different boundary conditions. However, the exponents of these empirical power-laws are at odds with the analytic values of n=1 and m=2, valid for low-density cellular structures in the limit of thin beams. We propose a functional form for K(ϕ) that models the cross-over from a power-law at low densities to a porous solid at high densities; a fit of the data to this functional form yields the asymptotic exponent n≈1.00, as expected. Further, both the intensity of the Poisson-Voronoi process and the collagen concentration in the samples, both of which alter the typical pore or mesh size, affect the effective moduli only by the resulting change of the solid volume fraction. These findings suggest that a network solid with the structure of the collagen networks can be modeled in quantitative agreement by a Poisson-Voronoi process. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Shepard, Jaclyn A.; Huang, Alyssa; Shikanova, Ariella; Shea, Lonnie D.
2010-01-01
In regenerative medicine, hydrogels are employed to fill defects and support the infiltration of cells that can ultimately regenerate tissue. Gene delivery within hydrogels targeting infiltrating cells has the potential to promote tissue formation, but the delivery efficiency of nonviral vectors within hydrogels is low hindering their applicability in tissue regeneration. To improve their functionality, we have conducted a mechanistic study to investigate the contribution of cell migration and matrix degradation on gene delivery. In this report, lipoplexes were entrapped within hydrogels based on poly(ethylene glycol) (PEG) crosslinked with peptides containing matrix metalloproteinase degradable sequences. The mesh size of these hydrogels is substantially less than the size of the entrapped lipoplexes, which can function to retain vectors. Cell migration and transfection were simultaneously measured within hydrogels with varying density of cell adhesion sites (Arg-Gly-Asp peptides) and solids content. Increasing RGD density increased expression levels up to 100-fold, while greater solids content sustained expression levels for 16 days. Increasing RGD density and decreasing solids content increased cell migration, which indicates expression levels increase with increased cell migration. Initially exposing cells to vector resulted in transient expression that declined after 2 days, verifying the requirement of migration to sustain expression. Transfected cells were predominantly located within the population of migrating cells for hydrogels that supported cell migration. Although the small mesh size retained at least 70% of the lipoplexes in the absence of cells after 32 days, the presence of cells decreased retention to 10% after 16 days. These results indicate that vectors retained within hydrogels contact migrating cells, and that persistent cell migration can maintain elevated expression levels. Thus matrix degradation and cell migration are fundamental design parameters for maximizing gene delivery from hydrogels. PMID:20450944
Gao, Yue; Krpata, David M; Criss, Cory N; Liu, Lijia; Posielski, Natasza; Rosen, Michael J; Novitsky, Yuri W
2014-08-01
The aim of this study was to reveal the effect of fibroblast or mesenchymal stem cell (MSC) coating on the mesh-induced production of IL-1β, IL-6, and VEGF by macrophages. Four commonly used surgical meshes were tested in this study, including Parietex, SoftMesh, TIGR, and Strattice. One-square-centimeter pieces of each mesh were placed on top of a monolayer of human fibroblasts or rat MSCs. The coating status was monitored with a light microscope. The human promonocytic cell line U937 was induced to differentiate into macrophages (MΦ). Three weeks later, meshes were transferred to new 24-well plates and cocultured with the MΦs for 72 h. Culture medium was collected and analyzed for IL-1β, IL-6, and VEGF production using standard ELISA essays. Parallel mesh samples were fixed with paraformaldehyde or glutaraldehyde for histology or transmission electronic microscopy (TEM) analyses, respectively. Uncoated meshes induced increased production of all three cytokines compared with macrophages cultured alone. HF coating further increased the production of both IL-6 and VEGF but reduced IL-1β production. Except for the SoftMesh group, MSC coating significantly blunted release of all cytokines to levels even lower than with MΦs cultured alone. MΦs tended to deteriorate in the presence of MSCs. Both histology and TEM revealed intimate interactions between cell-coated meshes and MΦs. Cytokine response to fibroblast coating varied, while MSC coating blunted the immunogenic effect of both synthetic and biologic meshes in vitro. Cell coating appears to affect mesh biocompatibility and may become a key process in mesh evolution.
Meshes optimized for discrete exterior calculus (DEC).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mousley, Sarah C.; Deakin, Michael; Knupp, Patrick
We study the optimization of an energy function used by the meshing community to measure and improve mesh quality. This energy is non-traditional because it is dependent on both the primal triangulation and its dual Voronoi (power) diagram. The energy is a measure of the mesh's quality for usage in Discrete Exterior Calculus (DEC), a method for numerically solving PDEs. In DEC, the PDE domain is triangulated and this mesh is used to obtain discrete approximations of the continuous operators in the PDE. The energy of a mesh gives an upper bound on the error of the discrete diagonal approximationmore » of the Hodge star operator. In practice, one begins with an initial mesh and then makes adjustments to produce a mesh of lower energy. However, we have discovered several shortcomings in directly optimizing this energy, e.g. its non-convexity, and we show that the search for an optimized mesh may lead to mesh inversion (malformed triangles). We propose a new energy function to address some of these issues.« less
Hybrid seine for full fish community collections
McKenna, James E.; Waldt, Emily M.; Abbett, Ross; David, Anthony; Snyder, James
2013-01-01
Seines are simple and effective fish collection gears, but the net mesh size influences how well the catch represents the fish communities. We designed and tested a hybrid seine with a dual-mesh bag (1/4″ and 1/8″) and compared the fish assemblage collected by each mesh. The fine-mesh net retained three times as many fish and collected more species (as many as eight), including representatives of several rare species, than did the coarser mesh. The dual-mesh bag permitted us to compare both sizes and species retained by each layer and to develop species-specific abundance correction factors, which allowed comparison of catches with the coarse-mesh seine used for earlier collections. The results indicate that a hybrid seine with coarse-mesh wings and a fine-mesh bag would enhance future studies of fish communities, especially when small-bodied fishes or early life stages are the research focus.
Moon, I S; Chai, J K; Cho, K S; Wikesjö, U M; Kim, C K
1996-10-01
This study evaluates periodontal repair and biomaterial reaction following implantation of a polyglactin mesh with or without porous resorbable calcium carbonate (RCC) or porous replamineform hydroxyapatite (RHA) in conjunction with reconstructive surgery. Ligature- and surgically-induced interproximal periodontal defects of left and right mandibular premolar teeth in 7 dogs were used. Bilaterally, mesial defects of the 2nd, 3rd and 4th premolar teeth were treated with polyglactin mesh, polyglactin mesh and RHA, or polyglactin mesh and RCC, respectively. The polyglactin mesh, shaped according to the contour of the defect, was adapted to the experimental teeth; its coronal margin positioned immediately apical to the cemento-enamel junction. Gingival flap margins were adapted and sutured to cover the polyglactin mesh completely. Clinical healing was generally uneventful. The dogs were sacrificed to provide block sections for histologic evaluation at 1, 3, 6, 12, 26, 32 and 56 weeks following wound closure. Generally, cementum regeneration was observed beginning at week 6 in all groups. Bone regeneration was observed from week 3 in polyglactin mesh-treated groups, and from week 6 in polyglactin mesh+RCC or polyglactin mesh+RHA treated groups. Bone regeneration appeared enhanced in polyglactin mesh+RCC or polyglactin mesh+RHA treated defects at week 12 and 26, with little difference between the three experimental conditions at week 56. Polyglactin mesh degradation was observed at week 3 and appeared complete at week 12. The RHA did not appear to resorb, while the RCC was gradually replaced by bone from week 3. Within limitations of the study conditions, periodontal regeneration was observed following implantation of a polyglactin mesh with or without RCC or RHA in conjunction with reconstructive surgery. As a conclusion, there seems to be no significant difference in periodontal regeneration after 12 months of healing between the group treated with the membrane only, and the group treated with the membrane and the bone substitution material. Changes in connective fiber orientation over the 1st 12 weeks of healing may suggest that "fibrous encapsulation" observed in earlier studies may only represent a transient stage in periodontal regeneration.
Park, Ji Sun; Song, Yookyung; Park, Daseul; Kim, Yeon-Won; Kim, Yoon Jin
2018-06-22
A facile one-pot synthetic method for preparing the Ag nanoparticle inks with a bimodal size distribution was newly devised and they were successfully employed as a conducting filler to form the metal-mesh type transparent conducting electrodes on the flexible substrate. Bimodal-sized Ag nanoparticles were synthesized through the polyol process, and their size variation was occurred via finely tuned composition ratio between Ag + ions and polymeric capping agents. The prepared bimodal-sized Ag nanoparticles exhibited the form of well-dispersed Ag nanoparticle inks without adding any dispersants and dispersion process. By filling the patterned micro-channels engraved on the flexible polymer substrate using a bimodal-sized Ag nanoparticle ink, a metal-mesh type transparent electrode (transmittance: 90% at 550 nm, haze: 1.5, area: 8 × 8 cm 2 ) was fabricated. By applying DC voltage to the mesh type electrode, a flexible transparent joule heater was successfully achieved with a performance of 4.5 °C s -1 heat-up rate at a low input power density.
NASA Astrophysics Data System (ADS)
Park, Ji Sun; Song, Yookyung; Park, Daseul; Kim, Yeon-Won; Kim, Yoon Jin
2018-06-01
A facile one-pot synthetic method for preparing the Ag nanoparticle inks with a bimodal size distribution was newly devised and they were successfully employed as a conducting filler to form the metal-mesh type transparent conducting electrodes on the flexible substrate. Bimodal-sized Ag nanoparticles were synthesized through the polyol process, and their size variation was occurred via finely tuned composition ratio between Ag+ ions and polymeric capping agents. The prepared bimodal-sized Ag nanoparticles exhibited the form of well-dispersed Ag nanoparticle inks without adding any dispersants and dispersion process. By filling the patterned micro-channels engraved on the flexible polymer substrate using a bimodal-sized Ag nanoparticle ink, a metal-mesh type transparent electrode (transmittance: 90% at 550 nm, haze: 1.5, area: 8 × 8 cm2) was fabricated. By applying DC voltage to the mesh type electrode, a flexible transparent joule heater was successfully achieved with a performance of 4.5 °C s‑1 heat-up rate at a low input power density.
Textile properties of synthetic prolapse mesh in response to uniaxial loading.
Barone, William R; Moalli, Pamela A; Abramowitch, Steven D
2016-09-01
Although synthetic mesh is associated with superior anatomic outcomes for the repair of pelvic organ prolapse, the benefits of mesh have been questioned because of the relatively high complication rates. To date, the mechanisms that result in such complications are poorly understood, yet the textile characteristics of mesh products are believed to play an important role. Interestingly, the pore diameter of synthetic mesh has been shown to impact the host response after hernia repair greatly, and such findings have served as design criteria for prolapse meshes, with larger pores viewed as more favorable. Although pore size and porosity are well-characterized before implantation, the changes in these textile properties after implantation are unclear; the application of mechanical forces has the potential to greatly alter pore geometries in vivo. Understanding the impact of mechanical loading on the textile properties of mesh is essential for the development of more effective devices for prolapse repair. The objective of this study was to determine the effect of tensile loading and pore orientation on mesh porosity and pore dimensions. In this study, the porosity and pore diameter of 4 currently available prolapse meshes were examined in response to uniaxial tensile loads of 0.1, 5, and 10 N while mimicking clinical loading conditions. The textile properties were compared with those observed for the unloaded mesh. Meshes included Gynemesh PS (Ethicon, Somerville, NJ), UltraPro (Artisyn; Ethicon), Restorelle (Coloplast, Minneapolis, MN), and Alyte Y-mesh (Bard, Covington, GA). In addition to the various pore geometries, 3 orientations of Restorelle (0-, 5-, 45-degree offset) and 2 orientations of UltraPro (0-, 90-degree offset) were examined. In response to uniaxial loading, both porosity and pore diameter dramatically decreased for most mesh products. The application of 5 N led to reductions in porosity for nearly all groups, with values decreasing by as much as 87% (P < .05). On loading to 10 N of force, nearly all mesh products that were tested were found to have porosities that approached 0% and 0 pores with diameters >1 mm. In this study, it was shown that the pore size of current prolapse meshes dramatically decreases in response to mechanical loading. These findings suggest that prolapse meshes, which are more likely to experience tensile forces in vivo relative to hernia repair meshes, have pores that are unfavorable for tissue integration after surgical tensioning and/or loading in urogynecologic surgeries. Such decreases in pore geometry support the hypothesis that regional increases in the concentration of mesh leads to an enhanced local foreign body response. Although pore deformation in transvaginal meshes requires further characterization, the findings presented here provide a mechanical understanding that can be used to recognize potential areas of concern for complex mesh geometries. Understanding mesh mechanics in response to surgical and in vivo loading conditions may provide improved design criteria for mesh and a refinement of surgical techniques, ultimately leading to better patient outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.
Conservative management of mesh-site infection in hernia repair surgery: a case series.
Meagher, H; Clarke Moloney, M; Grace, P A
2015-04-01
The aim of this study is to assess the outcome of conservative management of infected mesh grafts following abdominal wall hernia repair. This study retrospectively examined the charts of patients who developed mesh-site infection following surgery for abdominal hernia repair to determine how effective conservative management in the form of antibiotics and wound management was on the resolution of infection and wound healing. Over a period of 30 months, 13 patients developed infected mesh grafts post-hernia repair surgery. Twelve patients were successfully treated conservatively with local wound care and antibiotics if clinically indicated. One patient returned to theatre to have the infected mesh removed. Of the patients that healed eleven were treated with negative pressure wound therapy (VAC(®)). This series of case studies indicate that conservative management of abdominal wall-infected hernia mesh cases is likely to be successful.
Zimkowski, Michael M.; Rentschler, Mark E.; Schoen, Jonathan A.; Mandava, Nageswara; Shandas, Robin
2014-01-01
Approximately 400,000 ventral hernia repair surgeries are performed each year in the United States. Many of these procedures are performed using laparoscopic minimally invasive techniques and employ the use of surgical mesh. The use of surgical mesh has been shown to reduce recurrence rates compared to standard suture repairs. The placement of surgical mesh in a ventral hernia repair procedure can be challenging, and may even complicate the procedure. Others have attempted to provide commercial solutions to the problems of mesh placement, but these have not been well accepted by the clinical community. In this article, two versions of shape memory polymer (SMP)-modified surgical mesh, and unmodified surgical mesh, were compared by performing laparoscopic manipulation in an acute porcine model. Also, SMP-integrated polyester surgical meshes were implanted in four rats for 30–33 days to evaluate chronic biocompatibility and capacity for tissue integration. Porcine results show that the modified mesh provides a controlled, temperature-activated, automated deployment when compared to an unmodified mesh. In rats, results indicate that implanted SMP-modified meshes exhibit exceptional biocompatibility and excellent integration with surrounding tissue with no noticeable differences from the unmodified counterpart. This article provides further evidence that an SMP-modified surgical mesh promises reduction in surgical placement time and that such a mesh is not substantially different from unmodified meshes in chronic biocompatibility. PMID:24327401
Mirjavan, Mohammad; Asayesh, Azita; Asgharian Jeddi, Ali Asghar
2017-02-01
Surgical mesh is being used for healing hernia, pelvic organ prolapse, skull injuries and urinary incontinence. In this research the effect of fabric structure on the mechanical properties of warp knitted surgical meshes in comparison to abdominal fascia has been investigated. For this purpose, warp knitted surgical mesh with five different structures (Tricot, Pin-hole-net, quasi-Sandfly, Sandfly and quasi-Marquissite) were produced using polypropylene monofilament. Thereafter, their mechanical properties such as uniaxial tensile behavior in various directions (wale-wise (90°), course-wise (0°) and diagonal (45°)), bending resistance and crease recovery were analyzed. The meshes demonstrated different elastic modulus in various directions, which can be attributed to the pore shape (pore angle) and underlap angle in the structure of mesh. Except Pin-hole-net mesh, other produced meshes exhibited better level of orthotropy in comparison to abdominal fascia. The most flexible mesh in both wale-wise and course-wise directions was quasi-Sandfly and thereafter quasi-Marquissite. Tricot and Pin-hole-net manifested the highest crease recovery in wale-wise and coursewise directions respectively. The most desirable mesh in terms of porosity was quasi-Marquissite mesh. Overall, the quasi-Marquissite mesh was selected as the most suitable surgical mesh considering all advantages and disadvantages of each produced mesh in this study. Copyright © 2016 Elsevier Ltd. All rights reserved.
Highly Symmetric and Congruently Tiled Meshes for Shells and Domes
Rasheed, Muhibur; Bajaj, Chandrajit
2016-01-01
We describe the generation of all possible shell and dome shapes that can be uniquely meshed (tiled) using a single type of mesh face (tile), and following a single meshing (tiling) rule that governs the mesh (tile) arrangement with maximal vertex, edge and face symmetries. Such tiling arrangements or congruently tiled meshed shapes, are frequently found in chemical forms (fullerenes or Bucky balls, crystals, quasi-crystals, virus nano shells or capsids), and synthetic shapes (cages, sports domes, modern architectural facades). Congruently tiled meshes are both aesthetic and complete, as they support maximal mesh symmetries with minimal complexity and possess simple generation rules. Here, we generate congruent tilings and meshed shape layouts that satisfy these optimality conditions. Further, the congruent meshes are uniquely mappable to an almost regular 3D polyhedron (or its dual polyhedron) and which exhibits face-transitive (and edge-transitive) congruency with at most two types of vertices (each type transitive to the other). The family of all such congruently meshed polyhedra create a new class of meshed shapes, beyond the well-studied regular, semi-regular and quasi-regular classes, and their duals (platonic, Catalan and Johnson). While our new mesh class is infinite, we prove that there exists a unique mesh parametrization, where each member of the class can be represented by two integer lattice variables, and moreover efficiently constructable. PMID:27563368
Lu, S; Hu, W; Zhang, Z; Ji, Z; Zhang, T
2018-05-18
This study evaluated the manufacturing method and anti-adhesion properties of a new composite mesh in the rat model, which was made from sirolimus (SRL) grafts on a poly(L-lactic acid) (PLLA)-modified polypropylene (PP) hernia mesh. PLLA was first grafted onto argon-plasma-treated native PP mesh through catalysis of stannous chloride. SRL was grafted onto the surface of PP-PLLA meshes using catalysis of 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and 4-dimethylaminopyridine (DMAP) in a CH 2 Cl 2 solvent. Sprague-Dawley female rats received either SRL-coated meshes, PP-PLLA meshes, or native PP meshes to repair abdominal wall defects. At different intervals, rats were euthanized by a lethal dose of chloral hydrate and adhesion area and tenacity were evaluated. Sections of the mesh with adjacent tissues were assessed histologically. Attenuated total reflection Fourier transformed infrared (ATR-FTIR) spectroscopy indicated the existence of a C=O group absorption peak (1724.1 cm -1 ), and scanning electron microscope morphological analysis indicated that the surface of the PP mesh was covered with SRL. Compared to the native PP meshes and PP-PLLA meshes, SRL-coated meshes demonstrated the greatest ability to decrease the formation of adhesions (P < 0.05) and inflammation. The SRL-coated composite mesh showed minimal formation of intra-abdominal adhesions in a rat model of abdominal wall defect repair.
Berrevoet, F; Tollens, T; Berwouts, L; Bertrand, C; Muysoms, F; De Gols, J; Meir, E; De Backer, A
2014-01-01
A variety of anti-adhesive composite mesh products have become available to use inside the peritoneal cavity. However, reimbursement of these meshes by the Belgian Governemental Health Agency (RIZIV/INAMI) can only be obtained after conducting a prospective study with at least one year of clinical follow-up. This -Belgian multicentric cohort study evaluated the experience with the use of Proceed®-mesh in laparoscopic ventral hernia repair. During a 25 month period 210 adult patients underwent a laparoscopic primary or incisional hernia repair using an intra-abdominal placement of Proceed®-mesh. According to RIZIV/INAMI criteria recurrence rate after 1 year was the primary objective, while postoperative morbidity, including seroma formation, wound and mesh infections, quality of life and recurrences after 2 years were evaluated as secondary endpoints (NCT00572962). In total 97 primary ventral and 103 incisional hernias were repaired, of which 28 (13%) were recurrent. There were no conversions to open repair, no enterotomies, no mesh infections and no mortality. One year cumulative follow-up showed 10 recurrences (n = 192, 5.2%) and chronic discomfort or pain in 4.7% of the patients. Quality of life could not be analyzed due to incomplete data set. More than 5 years after introduction of this mesh to the market, this prospective multicentric study documents a favorable experience with the Proceed mesh in laparoscopic ventral hernia repair. However, it remains to be discussed whether reimbursement of these meshes in Belgium should be limited to the current strict criteria and therefore can only be obtained after at least 3-4 years of clinical data gathering and necessary follow-up. Copyright© Acta Chirurgica Belgica.
Endogan, T; Ozyaylali, I; Kulacoglu, H; Serbetci, K; Kiyak, G; Hasirci, N
2013-01-01
Prosthetic mesh repair for abdominal wall hernias is widely used because of its technical simplicity and low hernia recurrence rates. The most commonly used material is pure polypropylene mesh, although newer composite materials are recommended by some centers due to their advantages.However, these meshes are more expensive than pure polypropylene meshes. Resterilization of a pure polypropylene mesh has been shown to be quite safe, and many centers prefer slicing a large mesh into smaller pieces, suitable for any hernia type or defect size. Nevertheless there is no data about the safety after resterilization of the composite meshes. The present study was carried out to investigate the effects of resterilization and in vitro degradation in phosphate buffered saline solution on the physical structure and the mechanical properties of partially absorbable lightweight meshes. Two composite meshes were used in the study: One mesh consists of monofilament polypropylene and monofilament polyglecaprone -a copolymer of glycolide and epsilon(ε)- caprolactone - (Ultrapro®, 28 g m2, Ethicon, Hamburg,Germany), and the other one consisted of multifilament polypropylene and multifilament polyglactine (Vypro II®, 30g m2, Ethicon, Hamburg, Germany). Two large meshes were cut into rectangular specimens sized 50 x 20 mm for mechanical testing and 20 x 20 mm for in vitro degradation experiments.Meshes were divided into control group with no resterilization and gas resterilization. Ethylene oxide gas sterilization was performed at 55°C for 4.5 hours. In vitro degradation in 0.01M phosphate buffered saline (PBS, pH 7.4) solution at 37 ± 1°C for 8 weeks was applied to one subgroup in each mesh group. Tensiometric measurements and scanning electronmicroscopic evaluations were completed for control and resterilization specimens. Regardless of resterilization, when the meshes were exposed to in vitro degradation, all mechanical parameters decreased significantly. Highest reduction in mechanical properties was observed for Ultrapro due to the degradation of absorbable polyglecaprone and polyglactin parts of these meshes. It was observed that resterilization by ethylene oxide did not determine significant difference on the degradation characteristics and almost similar physical structures were observed for resterilized and non-resterilized meshes. For VyproII meshes, no significant mechanical difference was observed between resterilized and non-resterilized meshes after degradation while resterilized Ultrapro meshes exhibited stronger characteristics than non-resterilized counterparts, after degradation. Resterilization with ethylene oxide did not affect the mechanical properties of partially absorbable compositemeshes. No important surface changes were observed inscanning electron microscopy after resterilization. Celsius.
Ditzel, M; Deerenberg, E B; Grotenhuis, N; Harlaar, J J; Monkhorst, K; Bastiaansen-Jenniskens, Y M; Jeekel, J; Lange, J F
2013-10-01
In laparoscopic incisional hernia repair, direct contact between the prosthesis and the abdominal viscera is inevitable, which may lead to an inflammatory reaction resulting in abdominal adhesion formation. This study compared five different synthetic and biologic meshes in terms of adhesion formation, shrinkage, incorporation, and histologic characteristics after a period of 30 and 90 days. In 85 rats, a mesh was positioned intraperitoneally in direct contact with the viscera. Five different meshes were implanted: Prolene (polypropylene), Parietex composite (collagen-coated polyester), Strattice (porcine dermis, non-cross-linked), Surgisis (porcine small intestine submucosa, non-cross-linked), and Permacol (porcine dermis, cross-linked). The meshes were tested in terms of adhesion formation, shrinkage, and incorporation after a period of 30 and 90 days. Additionally, collagen formation after 90 days was determined. Significantly less adhesion formation was observed with Parietex composite (5 %; interquartile range [IQR], 2-5 %) and Strattice (5 %; IQR, 4-10 %) in the long term. In contrast, organs were attached to Permacol with four of seven meshes (57 %), and adhesion coverage of Surgisis mesh was present in 66 % (IQR, 0-100 %) of the cases. After 90 days, the best incorporation was seen with the Parietex composite mesh (79 %; IQR, 61-83 %). After 90 days, major alterations in adhesion formation were seen compared with 30 days. Histologically, Strattice and Parietex composite showed a new mesothelial layer on the visceral side of the mesh. Microscopic degradation and new collagen formation were seen in the Surgisis group. Parietex composite mesh demonstrated the best long-term results compared with all the other meshes. The biologic non-cross-linked mesh, Strattice, showed little adhesion formation and moderate shrinkage but poor incorporation. Biologic meshes are promising, but varying results require a more detailed investigation and demonstrate that biologic meshes are not necessarily superior to synthetic meshes. The significant changes that take place between 30 and 90 days should lead to careful interpretation of short-term experimental results.
Haskins, Ivy N; Voeller, Guy R; Stoikes, Nathaniel F; Webb, David L; Chandler, Robert G; Phillips, Sharon; Poulose, Benjamin K; Rosen, Michael J
2017-05-01
The use of mesh during ventral hernia repair (VHR) is a well-accepted concept. However, the ideal location of mesh placement remains strongly debated. Although VHR with onlay mesh placement has historically been associated with a high rate of wound events, this surgical approach is technically less challenging than VHR with sublay mesh placement. The purpose of this study was to compare 30-day wound events after onlay mesh placement with adhesive fixation vs those after sublay mesh placement using the Americas Hernia Society Quality Collaborative database. All patients undergoing elective, open VHR with synthetic mesh placement from January 2013 through January 2016 were identified within the Americas Hernia Society Quality Collaborative. Only patients with clean wounds were included. Patients were divided into 2 groups: onlay mesh placement with the use of adhesive and sublay mesh placement. The association of mesh location with 30-day wound events was investigated using a matched analysis. A total of 1,854 patients met inclusion criteria; 1,761 (95.0%) underwent sublay mesh placement and 93 (5.0%) underwent onlay mesh placement with the use of adhesive. A 2:1 sublay to onlay matched analysis was performed based on factors previously shown to influence wound events after VHR. After matching, both groups had a lower mean Ventral Hernia Working Group grade and fewer associated comorbidities. There was no statistically significant difference between the sublay and onlay groups with respect to 30-day surgical site infections (2.9% vs 5.5%; p = 0.30), surgical site occurrences (15.2% vs 7.7%; p = 0.08), or surgical site occurrences requiring procedural intervention (8.2% vs 5.5%; p = 0.42). Ventral hernia repair with onlay mesh placement is a safe alternative to VHR with sublay mesh placement in low-risk patients. Additional studies are needed to determine the long-term mesh outcomes and recurrence rates in both of these groups. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Assigning categorical information to Japanese medical terms using MeSH and MEDLINE.
Onogi, Yuzo
2007-01-01
This paper reports on the assigning of MeSH (Medical Subject Headings) categories to Japanese terms in an English-Japanese dictionary using the titles and abstracts of articles indexed in MEDLINE. In a previous study, 30,000 of 80,000 terms in the dictionary were mapped to MeSH terms by normalized comparison. It was reasoned that if the remaining dictionary terms appeared in MEDLINE-indexed articles that are indexed using MeSH terms, then relevancies between the dictionary terms and MeSH terms could be calculated, and thus MeSH categories assigned. This study compares two approaches for calculating the weight matrix. One is the TF*IDF method and the other uses the inner product of two weight matrices. About 20,000 additional dictionary terms were identified in MEDLINE-indexed articles published between 2000 and 2004. The precision and recall of these algorithms were evaluated separately for MeSH terms and non-MeSH terms. Unfortunately, the precision and recall of the algorithms was not good, but this method will help with manual assignment of MeSH categories to dictionary terms.
2013-01-01
Background Screening of houses might have impact on density of indoor host-seeking Anopheles mosquitoes. A randomized trial of screening windows and doors with metal mesh, and closing openings on eves and walls by mud was conducted to assess if reduce indoor densities of biting mosquitoes. Methods Mosquitoes were collected in forty houses using Centers for Diseases Control and Prevention (CDC) light traps biweekly in March and April 2011. A randomization of houses into control and intervention groups was done based on the baseline data. Windows and doors of 20 houses were screened by metal mesh, and openings on the walls and eves closed by mud and the rest 20 houses were used as control group. Mosquitoes were collected biweekly in October and November 2011 from both control and intervention houses. A Generalized Estimating Equations (GEE) with a negative binomial error distribution was used to account for over dispersion of Anopheles arabiensis and culicine counts and repeated catches made in the same house. Results Screening doors and windows, and closing openings on eves and wall by mud reduced the overall indoor densities of An. arabiensis by 40%. The effect of screenings pronounced on unfed An. arabiensis by resulting 42% reduction in houses with interventions. The total costs for screening windows and doors, and to close openings on the eves and walls by mud was 7.34 USD per house. Conclusion Screening houses reduced indoor density of An. arabiensis, and it was cheap and can easily incorporated into malaria vector strategies by local communities, but improving doors and windows fitness for screening should be considered during house construction to increase the efficacy of screenings. PMID:24028542
Massebo, Fekadu; Lindtjørn, Bernt
2013-09-12
Screening of houses might have impact on density of indoor host-seeking Anopheles mosquitoes. A randomized trial of screening windows and doors with metal mesh, and closing openings on eves and walls by mud was conducted to assess if reduce indoor densities of biting mosquitoes. Mosquitoes were collected in forty houses using Centers for Diseases Control and Prevention (CDC) light traps biweekly in March and April 2011. A randomization of houses into control and intervention groups was done based on the baseline data. Windows and doors of 20 houses were screened by metal mesh, and openings on the walls and eves closed by mud and the rest 20 houses were used as control group. Mosquitoes were collected biweekly in October and November 2011 from both control and intervention houses. A Generalized Estimating Equations (GEE) with a negative binomial error distribution was used to account for over dispersion of Anopheles arabiensis and culicine counts and repeated catches made in the same house. Screening doors and windows, and closing openings on eves and wall by mud reduced the overall indoor densities of An. arabiensis by 40%. The effect of screenings pronounced on unfed An. arabiensis by resulting 42% reduction in houses with interventions. The total costs for screening windows and doors, and to close openings on the eves and walls by mud was 7.34 USD per house. Screening houses reduced indoor density of An. arabiensis, and it was cheap and can easily incorporated into malaria vector strategies by local communities, but improving doors and windows fitness for screening should be considered during house construction to increase the efficacy of screenings.
Tofu wastewater treatment by sediment microbial fuel cells
NASA Astrophysics Data System (ADS)
Rinaldi, W.; Abubakar; Rahmi, R. F.; Silmina
2018-03-01
This research aimed to measure power density generated by sediment microbial fuel cells (SMFCs) by varying anode position and wastewater concentration. Anode position was varied at 2 cm and 4 cm under the surface of sediment, while wastewater concentration varied into 25%, 50%, 75% and 100%. The electrodes employed was stainless steel mesh, while the organic subtrate source was taken from wastewater of soybean washing and boiling process. The sediment was taken from the Lamnyong River around the outlet of tofu industry wastewater. SMFCs was run until the power density was relatively small. The produced electricity represented in power density. The results of this research showed that power density was decreased over time. Generated power density by varying 2 cm and 4 cm position of anode under the sediment surface was not significantly different, while the lowest wastewater concentration, 25%, gave the highest power density.
Tam, Vernissia; Winger, Daniel G.; Nason, Katie S.
2015-01-01
Structured Abstract Background Equipoise exists regarding whether mesh cruroplasty during laparoscopic large hiatal hernia repair improves symptomatic outcomes compared to suture repair. Data Source Systematic literature review (MEDLINE and EMBASE) identified 13 studies (1194 patients; 521 suture and 673 mesh) comparing mesh versus suture cruroplasty during laparoscopic repair of large hiatal hernia. We abstracted data regarding symptom assessment, objective recurrence, and reoperation and performed meta-analysis. Conclusions The majority of studies reported significant symptom improvement. Data were insufficient to evaluate symptomatic versus asymptomatic recurrence. Time to evaluation was skewed toward longer follow-up after suture cruroplasty. Odds of recurrence (OR 0.51, 95% CI 0.30–0.87; overall p=0.014) but not need for reoperation (OR 0.42, 95% CI 0.13–1.37; overall p=0.149) were less after mesh cruroplasty. Quality of evidence supporting routine use of mesh cruroplasty is low. Mesh should be used at surgeon discretion until additional studies evaluating symptomatic outcomes, quality of life and long-term recurrence are available. PMID:26520872
Schoettler, Jan; Jussli-Melchers, Jill; Grothusen, Christina; Stracke, Lars; Schoeneich, Felix; Stohn, Simon; Hoffmann, Grischa; Cremer, Jochen
2011-10-01
Saphenous vein graft patency is frequently limited by degeneration. Experimental studies have indicated that rigid external support of venous grafts by a flexible, tubular nitinol mesh may improve graft patency. The study presented was part of a prospective, randomized, multicenter first-in-man trial investigating the safety and effectiveness of nitinol-supported venous grafts in coronary artery bypass graft (CABG) surgery. From our clinic, 25 subjects with multivessel coronary artery disease requiring saphenous vein graft CABG of the right coronary artery (RCA) and the circumflex artery were entered into the trial. Subjects were randomized to receive a mesh-supported graft on one of these arteries; the other vessel received an untreated vein graft. Graft patency was assessed by coronary angiography nine months after surgery. The implantation of mesh grafts was simple and safe. In 10 cases, a nitinol mesh-supported venous graft was anastomosed to the circumflex artery and in 15 cases to the RCA. All patients survived the observation period. A total of 72% of the patients underwent control coronary angiography. The patency rate of mesh-supported grafts was 27.8% nine months postoperatively. Conventional vein grafts showed an 85.7% patency, and arterial grafts had a 100% patency. No complications directly related to the implantation of mesh-supported grafts were observed. The promising experimental results of mesh-supported venous grafts could not be reproduced in the study presented. A critical item seems to be correct selection of nitinol mesh diameter, the anastomotic method and fixation of the mesh tube to the venous graft.
Array-based, parallel hierarchical mesh refinement algorithms for unstructured meshes
Ray, Navamita; Grindeanu, Iulian; Zhao, Xinglin; ...
2016-08-18
In this paper, we describe an array-based hierarchical mesh refinement capability through uniform refinement of unstructured meshes for efficient solution of PDE's using finite element methods and multigrid solvers. A multi-degree, multi-dimensional and multi-level framework is designed to generate the nested hierarchies from an initial coarse mesh that can be used for a variety of purposes such as in multigrid solvers/preconditioners, to do solution convergence and verification studies and to improve overall parallel efficiency by decreasing I/O bandwidth requirements (by loading smaller meshes and in memory refinement). We also describe a high-order boundary reconstruction capability that can be used tomore » project the new points after refinement using high-order approximations instead of linear projection in order to minimize and provide more control on geometrical errors introduced by curved boundaries.The capability is developed under the parallel unstructured mesh framework "Mesh Oriented dAtaBase" (MOAB Tautges et al. (2004)). We describe the underlying data structures and algorithms to generate such hierarchies in parallel and present numerical results for computational efficiency and effect on mesh quality. Furthermore, we also present results to demonstrate the applicability of the developed capability to study convergence properties of different point projection schemes for various mesh hierarchies and to a multigrid finite-element solver for elliptic problems.« less
Conservative discretization of the Landau collision integral
Hirvijoki, E.; Adams, M. F.
2017-03-28
Here we describe a density, momentum-, and energy-conserving discretization of the nonlinear Landau collision integral. The method is suitable for both the finite-element and discontinuous Galerkin methods and does not require structured meshes. The conservation laws for the discretization are proven algebraically and demonstrated numerically for an axially symmetric nonlinear relaxation problem using a finite-element implementation.
Tissue response to collagen containing polypropylene meshes in an ovine vaginal repair model.
Darzi, Saeedeh; Urbankova, Iva; Su, Kai; White, Jacinta; Lo, Camden; Alexander, David; Werkmeister, Jerome A; Gargett, Caroline E; Deprest, Jan
2016-07-15
Pelvic Organ Prolapse (POP) is the herniation of pelvic organs into the vagina. Despite broad acceptance of mesh use in POP surgical repair, the complication rate is unacceptable. We hypothesized that collagen-containing polypropylene (PP) mesh types could modulate mesh-tissue integration and reduce long-term inflammation, thereby reducing mesh-associated complications. This study compared the long-term tissue response to an unmodified PP mesh and two collagen containing meshes in an ovine model which has similar pelvic anatomy and vaginal size to human. Three commercially available macroporous PP meshes, uncoated PP mesh (Avaulta Solo) (PP), the same textile PP mesh layered with a sheet of cross-linked porcine acellular matrix (Avaulta Plus) (PP-ACM) and a different yet also macroporous PP (Sofradim) mesh coated with solubilized atelocollagen (Ugytex) (PP-sCOL) were implanted in the ovine vagina and tissue explanted after 60 and 180days. The macrophage phenotype and response to implanted meshes, and vascularity were quantified by immunostaining and morphometry. We quantified changes in extracellular matrix composition biochemically and collagen organisation and percentage area around the interface of the mesh implants by Sirius Red birefringence and morphometry. PP-ACM induced a more sustained inflammatory response, indicated by similar CD45(+) leukocytes but reduced CD163(+) M2 macrophages at 60days (P<0.05). PP-sCOL increased Von Willebrand Factor (vWF)-immunoreactive vessel profiles after 60days. At the micro-molecular level, collagen birefringence quantification revealed significantly fewer mature collagen fibrils (red, thick fibrils) at the mesh-tissue interface than control tissue for all mesh types (P<0.001) but still significantly greater than the proportion of immature (green thin fibrils) at 60days (P<0.05). The proportion of mature collagen fibrils increased with time around the mesh filaments, particularly those containing collagen. The total collagen percent area at the mesh interface was greatest around the PP-ACM mesh at 60days (P<0.05). By 180days the total mature and immature collagen fibres at the interface of the mesh filaments resembled that of native tissue. In particular, these results suggest that both meshes containing collagen evoke different types of tissue responses at different times during the healing response yet both ultimately lead to physiological tissue formation approaching that of normal tissue. Pelvic organ prolapse (POP) is the descent of the pelvic organs to the vagina. POP affects more than 25% of all women and the lifetime risk of undergoing POP surgery is 19%. Although synthetic polypropylene (PP) meshes have improved the outcome of the surgical treatment for POP, there was an unacceptable rate of adverse events including mesh exposure and contracture. It is hypothesized that coating the PP meshes with collagen would provide a protective effect by preventing severe mesh adhesions to the wound, resulting in a better controlled initial inflammatory response, and diminished risk of exposure. In this study we assessed the effect of two collagen-containing PP meshes on the long-term vaginal tissue response using new techniques to quantify these tissue responses. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Computer aided stress analysis of long bones utilizing computer tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marom, S.A.
1986-01-01
A computer aided analysis method, utilizing computed tomography (CT) has been developed, which together with a finite element program determines the stress-displacement pattern in a long bone section. The CT data file provides the geometry, the density and the material properties for the generated finite element model. A three-dimensional finite element model of a tibial shaft is automatically generated from the CT file by a pre-processing procedure for a finite element program. The developed pre-processor includes an edge detection algorithm which determines the boundaries of the reconstructed cross-sectional images of the scanned bone. A mesh generation procedure than automatically generatesmore » a three-dimensional mesh of a user-selected refinement. The elastic properties needed for the stress analysis are individually determined for each model element using the radiographic density (CT number) of each pixel with the elemental borders. The elastic modulus is determined from the CT radiographic density by using an empirical relationship from the literature. The generated finite element model, together with applied loads, determined from existing gait analysis and initial displacements, comprise a formatted input for the SAP IV finite element program. The output of this program, stresses and displacements at the model elements and nodes, are sorted and displayed by a developed post-processor to provide maximum and minimum values at selected locations in the model.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Z.; Department of Applied Mathematics and Mechanics, University of Science and Technology Beijing, Beijing 100083; Lin, P.
In this paper, we investigate numerically a diffuse interface model for the Navier–Stokes equation with fluid–fluid interface when the fluids have different densities [48]. Under minor reformulation of the system, we show that there is a continuous energy law underlying the system, assuming that all variables have reasonable regularities. It is shown in the literature that an energy law preserving method will perform better for multiphase problems. Thus for the reformulated system, we design a C{sup 0} finite element method and a special temporal scheme where the energy law is preserved at the discrete level. Such a discrete energy lawmore » (almost the same as the continuous energy law) for this variable density two-phase flow model has never been established before with C{sup 0} finite element. A Newton method is introduced to linearise the highly non-linear system of our discretization scheme. Some numerical experiments are carried out using the adaptive mesh to investigate the scenario of coalescing and rising drops with differing density ratio. The snapshots for the evolution of the interface together with the adaptive mesh at different times are presented to show that the evolution, including the break-up/pinch-off of the drop, can be handled smoothly by our numerical scheme. The discrete energy functional for the system is examined to show that the energy law at the discrete level is preserved by our scheme.« less
NASA Astrophysics Data System (ADS)
Patel, Jitendra Kumar; Natarajan, Ganesh
2017-12-01
We discuss the development and assessment of a robust numerical algorithm for simulating multiphase flows with complex interfaces and high density ratios on arbitrary polygonal meshes. The algorithm combines the volume-of-fluid method with an incremental projection approach for incompressible multiphase flows in a novel hybrid staggered/non-staggered framework. The key principles that characterise the algorithm are the consistent treatment of discrete mass and momentum transport and the similar discretisation of force terms appearing in the momentum equation. The former is achieved by invoking identical schemes for convective transport of volume fraction and momentum in the respective discrete equations while the latter is realised by representing the gravity and surface tension terms as gradients of suitable scalars which are then discretised in identical fashion resulting in a balanced formulation. The hybrid staggered/non-staggered framework employed herein solves for the scalar normal momentum at the cell faces, while the volume fraction is computed at the cell centroids. This is shown to naturally lead to similar terms for pressure and its correction in the momentum and pressure correction equations respectively, which are again treated discretely in a similar manner. We show that spurious currents that corrupt the solution may arise both from an unbalanced formulation where forces (gravity and surface tension) are discretised in dissimilar manner and from an inconsistent approach where different schemes are used to convect the mass and momentum, with the latter prominent in flows which are convection-dominant with high density ratios. Interestingly, the inconsistent approach is shown to perform as well as the consistent approach even for high density ratio flows in some cases while it exhibits anomalous behaviour for other scenarios, even at low density ratios. Using a plethora of test problems of increasing complexity, we conclusively demonstrate that the consistent transport and balanced force treatment results in a numerically stable solution procedure and physically consistent results. The algorithm proposed in this study qualifies as a robust approach to simulate multiphase flows with high density ratios on unstructured meshes and may be realised in existing flow solvers with relative ease.
Male infertility after mesh hernia repair: A prospective study.
Hallén, Magnus; Sandblom, Gabriel; Nordin, Pär; Gunnarsson, Ulf; Kvist, Ulrik; Westerdahl, Johan
2011-02-01
Several animal studies have raised concern about the risk for obstructive azoospermia owing to vasal fibrosis caused by the use of alloplastic mesh prosthesis in inguinal hernia repair. The aim of this study was to determine the prevalence of male infertility after bilateral mesh repair. In a prospective study, a questionnaire inquiring about involuntary childlessness, investigation for infertility and number of children was sent by mail to a group of 376 men aged 18-55 years, who had undergone bilateral mesh repair, identified in the Swedish Hernia Register (SHR). Questionnaires were also sent to 2 control groups, 1 consisting of 186 men from the SHR who had undergone bilateral repair without mesh, and 1 consisting of 383 men identified in the general population. The control group from the SHR was matched 2:1 for age and years elapsed since operation. The control group from the general population was matched 1:1 for age and marital status. The overall response rate was 525 of 945 (56%). Method of approach (anterior or posterior), type of mesh, and testicular status at the time of the repair had no significant impact on the answers to the questions. Nor did subgroup analysis of the men ≤40 years old reveal any significant differences. The results of this prospective study in men do not support the hypothesis that bilateral inguinal hernia repair with alloplastic mesh prosthesis causes male infertility at a significantly greater rate than those operated without mesh. Copyright © 2011 Mosby, Inc. All rights reserved.
Spatial heterogeneity in the carrying capacity of sika deer in Japan
Iijima, Hayato; Ueno, Mayumi
2016-01-01
Abstract Carrying capacity is 1 driver of wildlife population dynamics. Although in previous studies carrying capacity was considered to be a fixed entity, it may differ among locations due to environmental variation. The factors underlying variability in carrying capacity, however, have rarely been examined. Here, we investigated spatial heterogeneity in the carrying capacity of Japanese sika deer ( Cervus nippon ) from 2005 to 2014 in Yamanashi Prefecture, central Japan (mesh with grid cells of 5.5×4.6 km) by state-space modeling. Both carrying capacity and density dependence differed greatly among cells. Estimated carrying capacities ranged from 1.34 to 98.4 deer/km 2 . According to estimated population dynamics, grid cells with larger proportions of artificial grassland and deciduous forest were subject to lower density dependence and higher carrying capacity. We conclude that population dynamics of ungulates may vary spatially through spatial variation in carrying capacity and that the density level for controlling ungulate abundance should be based on the current density level relative to the carrying capacity for each area. PMID:29692470
Component extraction on CT volumes of assembled products using geometric template matching
NASA Astrophysics Data System (ADS)
Muramatsu, Katsutoshi; Ohtake, Yutaka; Suzuki, Hiromasa; Nagai, Yukie
2017-03-01
As a method of non-destructive internal inspection, X-ray computed tomography (CT) is used not only in medical applications but also for product inspection. Some assembled products can be divided into separate components based on density, which is known to be approximately proportional to CT values. However, components whose densities are similar cannot be distinguished using the CT value driven approach. In this study, we proposed a new component extraction algorithm from the CT volume, using a set of voxels with an assigned CT value with the surface mesh as the template rather than the density. The method has two main stages: rough matching and fine matching. At the rough matching stage, the position of candidate targets is identified roughly from the CT volume, using the template of the target component. At the fine matching stage, these candidates are precisely matched with the templates, allowing the correct position of the components to be detected from the CT volume. The results of two computational experiments showed that the proposed algorithm is able to extract components with similar density within the assembled products on CT volumes.
Monte Carlo design of optimal wire mesh collimator for breast tumor imaging process
NASA Astrophysics Data System (ADS)
Saad, W. H. M.; Roslan, R. E.; Mahdi, M. A.; Choong, W.-S.; Saion, E.; Saripan, M. I.
2011-08-01
This paper presents the modeling of breast tumor imaging process using wire mesh collimator gamma camera. Previous studies showed that the wire mesh collimator has a potential to improve the sensitivity of the tumor detection. In this paper, we extend our research significantly, to find an optimal configuration of the wire mesh collimator specifically for semi-compressed breast tumor detection, by looking into four major factors: weight, sensitivity, spatial resolution and tumor contrast. The numbers of layers in the wire mesh collimator is varied to optimize the collimator design. The statistical variations of the results are studied by simulating multiple realizations for each experiment using different starting random numbers. All the simulation environments are modeled using Monte Carlo N-Particle Code (MCNP). The quality of the detection is measured directly by comparing the sensitivity, spatial resolution and tumor contrast of the images produced by the wire mesh collimator and benchmarked that with a standard multihole collimator. The proposed optimal configuration of the wire mesh collimator is optimized by selecting the number of layers in wire mesh collimator, where the tumor contrast shows a relatively comparable value to the multihole collimator, when it is tested with uniformly semi-compressed breast phantom. The wire mesh collimator showed higher number of sensitivity because of its loose arrangement while the spatial resolution of wire mesh collimator does not shows much different compared to the multihole collimator. With a relatively good tumor contrast and spatial resolution, and increased in sensitivity, a new proposed wire mesh collimator gives a significant improvement in the wire mesh collimator design for breast cancer imaging process. The proposed collimator configuration is reduced to 44.09% from the total multihole collimator weight.
Muir, Kathryn B; Smoot, Charles P; Viera, Jennifer L; Sirkin, Maxwell R; Yoon, Brian; Bader, Julia; Smiley, Rebecca; Holt, Danielle; Hofmann, Luke J
2018-04-01
Controversy exists regarding the appropriate timing for placement of permanent intra-abdominal mesh after inadvertent enterotomy during elective hernia repair. The aim of this study was to examine mesh placement at variable postoperative periods and the subsequent risk of infection. Fifty rodents were divided into five groups. Groups one to four underwent laparotomy, enterotomy, and repair. Physiomesh® was placed at the index operation one, three, or seven days postoperatively in Groups 1, 2, 3, and 4. Group 5 underwent mesh placement only. Necropsy with mesh harvest was performed seven days after placement. Cultures of mesh were obtained and Fisher's exact test was used to compare groups. Bacterial growth postsonication was identified in 30, 30, 50, and 90 per cent versus 20 per cent in controls. Compared with controls, there was significantly increased risk of mesh infection when it was placed seven days after enterotomy (P = 0.006). There was no significant difference in bacterial growth when mesh was placed at the time of enterotomy, one or three days later. The risk of bacterial contamination of permanent mesh placed immediately after inadvertent enterotomy during elective hernia repair is as safe as placing mesh at one or three days. Placing mesh at seven days significantly increased the risk of mesh contamination.
Longest, P Worth; Vinchurkar, Samir
2007-04-01
A number of research studies have employed a wide variety of mesh styles and levels of grid convergence to assess velocity fields and particle deposition patterns in models of branching biological systems. Generating structured meshes based on hexahedral elements requires significant time and effort; however, these meshes are often associated with high quality solutions. Unstructured meshes that employ tetrahedral elements can be constructed much faster but may increase levels of numerical diffusion, especially in tubular flow systems with a primary flow direction. The objective of this study is to better establish the effects of mesh generation techniques and grid convergence on velocity fields and particle deposition patterns in bifurcating respiratory models. In order to achieve this objective, four widely used mesh styles including structured hexahedral, unstructured tetrahedral, flow adaptive tetrahedral, and hybrid grids have been considered for two respiratory airway configurations. Initial particle conditions tested are based on the inlet velocity profile or the local inlet mass flow rate. Accuracy of the simulations has been assessed by comparisons to experimental in vitro data available in the literature for the steady-state velocity field in a single bifurcation model as well as the local particle deposition fraction in a double bifurcation model. Quantitative grid convergence was assessed based on a grid convergence index (GCI), which accounts for the degree of grid refinement. The hexahedral mesh was observed to have GCI values that were an order of magnitude below the unstructured tetrahedral mesh values for all resolutions considered. Moreover, the hexahedral mesh style provided GCI values of approximately 1% and reduced run times by a factor of 3. Based on comparisons to empirical data, it was shown that inlet particle seedings should be consistent with the local inlet mass flow rate. Furthermore, the mesh style was found to have an observable effect on cumulative particle depositions with the hexahedral solution most closely matching empirical results. Future studies are needed to assess other mesh generation options including various forms of the hybrid configuration and unstructured hexahedral meshes.
NASA Technical Reports Server (NTRS)
Hoerz, Friedrich; Cintala, Mark J.; Bernhard, Ronald P.; Cardenas, Frank; Davidson, William; Haynes, Gerald; See, Thomas H.; Winkler, Jerry; Gray, Barry
1993-01-01
The utility of multiple-mesh targets as potential lightweight shields to protect spacecraft in low-Earth orbit against collisional damage is explored. Earlier studies revealed that single meshes comminute hypervelocity impactors with efficiencies comparable to contiguous targets. Multiple interaction of projectile fragments with any number of meshes should lead to increased comminution, deceleration, and dispersion of the projectile, such that all debris exiting the mesh stack possesses low specific energies (ergs/sq cm) that would readily be tolerated by many flight systems. The study is conceptually exploring the sensitivity of major variables such as impact velocity, the specific areal mass (g/sq cm) of the total mesh stack (SM), and the separation distance (S) between individual meshes. Most experiments employed five or ten meshes with total SM typically less than 0.5 the specific mass of the impactor, and silicate glass impactors rather than metal projectiles. While projectile comminution increases with increasing impact velocity due to progressively higher shock stresses, encounters with multiple-meshes at low velocity (1-2 km/s) already lead to significant disruption of the glass impactors, with the resulting fragments being additionally decelerated and dispersed by subsequent meshes, and, unlike most contiguous single-plate bumpers, leading to respectable performance at low velocity. Total specific bumper mass must be the subject of careful trade-off studies; relatively massive bumpers will generate too much debris being dislodged from the bumper itself, while exceptionally lightweight designs will not cause sufficient comminution, deceleration, or dispersion of the impactor. Separation distance was found to be a crucial design parameter, as it controls the dispersion of the fragment cloud. Substantial mass savings could result if maximum separation distances were employed. The total mass of debris dislodged by multiple-mesh stacks is modestly smaller than that of single, contiguous-membrane shields. The cumulative surface area of all penetration holes in multiple mesh stacks is an order of magnitude smaller than that in analog multiple-foil shields, suggesting good long-term performance of the mesh designs. Due to different experimental conditions, direct and quantitative comparison with other lightweight shields is not possible at present.
An efficient and robust 3D mesh compression based on 3D watermarking and wavelet transform
NASA Astrophysics Data System (ADS)
Zagrouba, Ezzeddine; Ben Jabra, Saoussen; Didi, Yosra
2011-06-01
The compression and watermarking of 3D meshes are very important in many areas of activity including digital cinematography, virtual reality as well as CAD design. However, most studies on 3D watermarking and 3D compression are done independently. To verify a good trade-off between protection and a fast transfer of 3D meshes, this paper proposes a new approach which combines 3D mesh compression with mesh watermarking. This combination is based on a wavelet transformation. In fact, the used compression method is decomposed to two stages: geometric encoding and topologic encoding. The proposed approach consists to insert a signature between these two stages. First, the wavelet transformation is applied to the original mesh to obtain two components: wavelets coefficients and a coarse mesh. Then, the geometric encoding is done on these two components. The obtained coarse mesh will be marked using a robust mesh watermarking scheme. This insertion into coarse mesh allows obtaining high robustness to several attacks. Finally, the topologic encoding is applied to the marked coarse mesh to obtain the compressed mesh. The combination of compression and watermarking permits to detect the presence of signature after a compression of the marked mesh. In plus, it allows transferring protected 3D meshes with the minimum size. The experiments and evaluations show that the proposed approach presents efficient results in terms of compression gain, invisibility and robustness of the signature against of many attacks.
A Numerical Study of Mesh Adaptivity in Multiphase Flows with Non-Newtonian Fluids
NASA Astrophysics Data System (ADS)
Percival, James; Pavlidis, Dimitrios; Xie, Zhihua; Alberini, Federico; Simmons, Mark; Pain, Christopher; Matar, Omar
2014-11-01
We present an investigation into the computational efficiency benefits of dynamic mesh adaptivity in the numerical simulation of transient multiphase fluid flow problems involving Non-Newtonian fluids. Such fluids appear in a range of industrial applications, from printing inks to toothpastes and introduce new challenges for mesh adaptivity due to the additional ``memory'' of viscoelastic fluids. Nevertheless, the multiscale nature of these flows implies huge potential benefits for a successful implementation. The study is performed using the open source package Fluidity, which couples an unstructured mesh control volume finite element solver for the multiphase Navier-Stokes equations to a dynamic anisotropic mesh adaptivity algorithm, based on estimated solution interpolation error criteria, and conservative mesh-to-mesh interpolation routine. The code is applied to problems involving rheologies ranging from simple Newtonian to shear-thinning to viscoelastic materials and verified against experimental data for various industrial and microfluidic flows. This work was undertaken as part of the EPSRC MEMPHIS programme grant EP/K003976/1.
Karell, Mara A; Langstaff, Helen K; Halazonetis, Demetrios J; Minghetti, Caterina; Frelat, Mélanie; Kranioti, Elena F
2016-09-01
The commingling of human remains often hinders forensic/physical anthropologists during the identification process, as there are limited methods to accurately sort these remains. This study investigates a new method for pair-matching, a common individualization technique, which uses digital three-dimensional models of bone: mesh-to-mesh value comparison (MVC). The MVC method digitally compares the entire three-dimensional geometry of two bones at once to produce a single value to indicate their similarity. Two different versions of this method, one manual and the other automated, were created and then tested for how well they accurately pair-matched humeri. Each version was assessed using sensitivity and specificity. The manual mesh-to-mesh value comparison method was 100 % sensitive and 100 % specific. The automated mesh-to-mesh value comparison method was 95 % sensitive and 60 % specific. Our results indicate that the mesh-to-mesh value comparison method overall is a powerful new tool for accurately pair-matching commingled skeletal elements, although the automated version still needs improvement.
van Iersel, Jan J; Formijne Jonkers, Hendrik A; Paulides, Tim J C; Verheijen, Paul M; Draaisma, Werner A; Consten, Esther C J; Broeders, Ivo A M J
2017-11-01
Laparoscopic ventral mesh rectopexy is being increasingly performed internationally to treat rectal prolapse syndromes. Robotic assistance appears advantageous for this procedure, but literature regarding robot-assisted ventral mesh rectopexy is limited. The primary objective of this study was to assess the safety and effectiveness of robot-assisted ventral mesh rectopexy in the largest consecutive series of patients to date. This study is a retrospective cross-sectional analysis of prospectively collected data. The study was conducted in a tertiary referral center. All of the patients undergoing robot-assisted ventral mesh rectopexy for rectal prolapse syndromes between 2010 and 2015 were evaluated. Preoperative and postoperative (mesh and nonmesh) morbidity and functional outcome were analyzed. The actuarial recurrence rates were calculated using the Kaplan-Meier method. A total of 258 patients underwent robot-assisted ventral mesh rectopexy (mean ± SD follow-up = 23.5 ± 21.8 mo; range, 0.2 - 65.1 mo). There were no conversions and only 5 intraoperative complications (1.9%). Mortality (0.4%) and major (1.9%) and minor (<30 d) early morbidity (7.0%) were acceptably low. Only 1 (1.3%) mesh-related complication (asymptomatic vaginal mesh erosion) was observed. A significant improvement in obstructed defecation (78.6%) and fecal incontinence (63.7%) were achieved for patients (both p < 0.0005). At final follow-up, a new onset of fecal incontinence and obstructed defecation was induced or worsened in 3.9% and 0.4%. The actuarial 5-year external rectal prolapse and internal rectal prolapse recurrence rates were 12.9% and 10.4%. This was a retrospective study including patients with minimal follow-up. No validated scores were used to assess function. The study was monocentric, and there was no control group. Robot-assisted ventral mesh rectopexy is a safe and effective technique to treat rectal prolapse syndromes, providing an acceptable recurrence rate and good symptomatic relief with minimal morbidity. See Video Abstract at http://links.lww.com/DCR/A427.
Im, So-Min; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin
2017-02-01
The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture ( P <.05) and the control group ( P <.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.
Criman, Erik T.; Kurata, Wendy E.; Matsumoto, Karen W.; Aubin, Harry T.; Campbell, Carmen E.
2016-01-01
Background: The reported incidence of mesh infection in contaminated operative fields is as high as 30% regardless of the material used. Recently, mesenchymal stem cells (MSCs) have been shown to possess favorable immunomodulatory properties and improve tissue incorporation when seeded onto bioprosthetics. The aim of this study was to evaluate whether seeding noncrosslinked bovine pericardium (Veritas Collagen Matrix) with allogeneic bone marrow–derived MSCs improves infection resistance in vivo after inoculation with Escherichia coli (E. coli). Methods: Rat bone marrow–derived MSCs at passage 3 were seeded onto bovine pericardium and cultured for 7 days before implantation. Additional rats (n = 24) were implanted subcutaneously with MSC-seeded or unseeded mesh and inoculated with 7 × 105 colony-forming units of E. coli or saline before wound closure (group 1, unseeded mesh/saline; group 2, unseeded mesh/E. coli; group 3, MSC-seeded mesh/E. coli; 8 rats per group). Meshes were explanted at 4 weeks and underwent microbiologic and histologic analyses. Results: MSC-seeded meshes inoculated with E. coli demonstrated superior bacterial clearance and preservation of mesh integrity compared with E. coli–inoculated unseeded meshes (87.5% versus 0% clearance; p = 0.001). Complete mesh degradation concurrent with abscess formation was observed in 100% of rats in the unseeded/E. coli group, which is in contrast to 12.5% of rats in the MSC-seeded/E. coli group. Histologic evaluation determined that remodeling characteristics of E. coli–inoculated MSC-seeded meshes were similar to those of uninfected meshes 4 weeks after implantation. Conclusions: Augmenting a bioprosthetic material with stem cells seems to markedly enhance resistance to bacterial infection in vivo and preserve mesh integrity. PMID:27482490
NASA Astrophysics Data System (ADS)
Zheng, H. W.; Shu, C.; Chew, Y. T.
2008-07-01
In this paper, an object-oriented and quadrilateral-mesh based solution adaptive algorithm for the simulation of compressible multi-fluid flows is presented. The HLLC scheme (Harten, Lax and van Leer approximate Riemann solver with the Contact wave restored) is extended to adaptively solve the compressible multi-fluid flows under complex geometry on unstructured mesh. It is also extended to the second-order of accuracy by using MUSCL extrapolation. The node, edge and cell are arranged in such an object-oriented manner that each of them inherits from a basic object. A home-made double link list is designed to manage these objects so that the inserting of new objects and removing of the existing objects (nodes, edges and cells) are independent of the number of objects and only of the complexity of O( 1). In addition, the cells with different levels are further stored in different lists. This avoids the recursive calculation of solution of mother (non-leaf) cells. Thus, high efficiency is obtained due to these features. Besides, as compared to other cell-edge adaptive methods, the separation of nodes would reduce the memory requirement of redundant nodes, especially in the cases where the level number is large or the space dimension is three. Five two-dimensional examples are used to examine its performance. These examples include vortex evolution problem, interface only problem under structured mesh and unstructured mesh, bubble explosion under the water, bubble-shock interaction, and shock-interface interaction inside the cylindrical vessel. Numerical results indicate that there is no oscillation of pressure and velocity across the interface and it is feasible to apply it to solve compressible multi-fluid flows with large density ratio (1000) and strong shock wave (the pressure ratio is 10,000) interaction with the interface.
Mesh Convergence Requirements for Composite Damage Models
NASA Technical Reports Server (NTRS)
Davila, Carlos G.
2016-01-01
The ability of the finite element method to accurately represent the response of objects with intricate geometry and loading renders the finite element method as an extremely versatile analysis technique for structural analysis. Finite element analysis is routinely used in industry to calculate deflections, stress concentrations, natural frequencies, buckling loads, and much more. The method works by discretizing complex problems into smaller, simpler approximations that are valid over small uniform domains. For common analyses, the maximum size of the elements that can be used is often be determined by experience. However, to verify the quality of a solution, analyses with several levels of mesh refinement should be performed to ensure that the solution has converged. In recent years, the finite element method has been used to calculate the resistance of structures, and in particular that of composite structures. A number of techniques such as cohesive zone modeling, the virtual crack closure technique, and continuum damage modeling have emerged that can be used to predict cracking, delaminations, fiber failure, and other composite damage modes that lead to structural collapse. However, damage models present mesh refinement requirements that are not well understood. In this presentation, we examine different mesh refinement issues related to the representation of damage in composite materials. Damage process zone sizes and their corresponding mesh requirements will be discussed. The difficulties of modeling discontinuities and the associated need for regularization techniques will be illustrated, and some unexpected element size constraints will be presented. Finally, some of the difficulties in constructing models of composite structures capable of predicting transverse matrix cracking will be discussed. It will be shown that to predict the initiation and propagation of transverse matrix cracks, their density, and their saturation may require models that are significantly more refined than those that have been contemplated in the past.
Analytical Round Robin for Elastic-Plastic Analysis of Surface Cracked Plates: Phase I Results
NASA Technical Reports Server (NTRS)
Wells, D. N.; Allen, P. A.
2012-01-01
An analytical round robin for the elastic-plastic analysis of surface cracks in flat plates was conducted with 15 participants. Experimental results from a surface crack tension test in 2219-T8 aluminum plate provided the basis for the inter-laboratory study (ILS). The study proceeded in a blind fashion given that the analysis methodology was not specified to the participants, and key experimental results were withheld. This approach allowed the ILS to serve as a current measure of the state of the art for elastic-plastic fracture mechanics analysis. The analytical results and the associated methodologies were collected for comparison, and sources of variability were studied and isolated. The results of the study revealed that the J-integral analysis methodology using the domain integral method is robust, providing reliable J-integral values without being overly sensitive to modeling details. General modeling choices such as analysis code, model size (mesh density), crack tip meshing, or boundary conditions, were not found to be sources of significant variability. For analyses controlled only by far-field boundary conditions, the greatest source of variability in the J-integral assessment is introduced through the constitutive model. This variability can be substantially reduced by using crack mouth opening displacements to anchor the assessment. Conclusions provide recommendations for analysis standardization.
Dense mesh sampling for video-based facial animation
NASA Astrophysics Data System (ADS)
Peszor, Damian; Wojciechowska, Marzena
2016-06-01
The paper describes an approach for selection of feature points on three-dimensional, triangle mesh obtained using various techniques from several video footages. This approach has a dual purpose. First, it allows to minimize the data stored for the purpose of facial animation, so that instead of storing position of each vertex in each frame, one could store only a small subset of vertices for each frame and calculate positions of others based on the subset. Second purpose is to select feature points that could be used for anthropometry-based retargeting of recorded mimicry to another model, with sampling density beyond that which can be achieved using marker-based performance capture techniques. Developed approach was successfully tested on artificial models, models constructed using structured light scanner, and models constructed from video footages using stereophotogrammetry.
Validation of Magnetic Resonance Thermometry by Computational Fluid Dynamics
NASA Astrophysics Data System (ADS)
Rydquist, Grant; Owkes, Mark; Verhulst, Claire M.; Benson, Michael J.; Vanpoppel, Bret P.; Burton, Sascha; Eaton, John K.; Elkins, Christopher P.
2016-11-01
Magnetic Resonance Thermometry (MRT) is a new experimental technique that can create fully three-dimensional temperature fields in a noninvasive manner. However, validation is still required to determine the accuracy of measured results. One method of examination is to compare data gathered experimentally to data computed with computational fluid dynamics (CFD). In this study, large-eddy simulations have been performed with the NGA computational platform to generate data for a comparison with previously run MRT experiments. The experimental setup consisted of a heated jet inclined at 30° injected into a larger channel. In the simulations, viscosity and density were scaled according to the local temperature to account for differences in buoyant and viscous forces. A mesh-independent study was performed with 5 mil-, 15 mil- and 45 mil-cell meshes. The program Star-CCM + was used to simulate the complete experimental geometry. This was compared to data generated from NGA. Overall, both programs show good agreement with the experimental data gathered with MRT. With this data, the validity of MRT as a diagnostic tool has been shown and the tool can be used to further our understanding of a range of flows with non-trivial temperature distributions.
Cold dark matter. 1: The formation of dark halos
NASA Technical Reports Server (NTRS)
Gelb, James M.; Bertschinger, Edmund
1994-01-01
We use numerical simulations of critically closed cold dark matter (CDM) models to study the effects of numerical resolution on observable quantities. We study simulations with up to 256(exp 3) particles using the particle-mesh (PM) method and with up to 144(exp 3) particles using the adaptive particle-particle-mesh (P3M) method. Comparisons of galaxy halo distributions are made among the various simulations. We also compare distributions with observations, and we explore methods for identifying halos, including a new algorithm that finds all particles within closed contours of the smoothed density field surrounding a peak. The simulated halos show more substructure than predicted by the Press-Schechter theory. We are able to rule out all omega = 1 CDM models for linear amplitude sigma(sub 8) greater than or approximately = 0.5 because the simulations produce too many massive halos compared with the observations. The simulations also produce too many low-mass halos. The distribution of halos characterized by their circular velocities for the P3M simulations is in reasonable agreement with the observations for 150 km/s less than or = V(sub circ) less than or = 350 km/s.
Simulations of a Molecular Cloud experiment using CRASH
NASA Astrophysics Data System (ADS)
Trantham, Matthew; Keiter, Paul; Vandervort, Robert; Drake, R. Paul; Shvarts, Dov
2017-10-01
Recent laboratory experiments explore molecular cloud radiation hydrodynamics. The experiment irradiates a gold foil with a laser producing x-rays to drive the implosion or explosion of a foam ball. The CRASH code, an Eulerian code with block-adaptive mesh refinement, multigroup diffusive radiation transport, and electron heat conduction developed at the University of Michigan to design and analyze high-energy-density experiments, is used to perform a parameter search in order to identify optically thick, optically thin and transition regimes suitable for these experiments. Specific design issues addressed by the simulations are the x-ray drive temperature, foam density, distance from the x-ray source to the ball, as well as other complicating issues such as the positioning of the stalk holding the foam ball. We present the results of this study and show ways the simulations helped improve the quality of the experiment. This work is funded by the LLNL under subcontract B614207 and NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, Grant Number DE-NA0002956.
Chronic pain after open inguinal hernia repair.
Nikkolo, Ceith; Lepner, Urmas
2016-01-01
Following the widespread use of mesh repairs, recurrence rates after inguinal hernia surgery have become acceptable and focus has shifted from recurrence to chronic pain. Although pain can be controlled with analgesics, chronic postsurgical pain is a major clinical problem, which can significantly influence the patient's quality of life. The rate of chronic pain after inguinal hernia mesh repair can reach 51.6%. The reasons for posthernioplasty chronic pain are often unclear. It has been linked to nerve injury and nerve entrapment, but there is also association between the rate of chronic pain and the type of mesh used for hernia repair. As there are >160 meshes available in the market, it is difficult to choose a mesh whose usage would result in the best outcome. Different mesh characteristics have been studied, among them weight of mesh has probably gained the most attention. The choice of adequate therapy for chronic groin pain after inguinal hernia repair is controversial. The European Hernia Society recommends that a multidisciplinary approach at a pain clinic should be considered for the treatment of chronic postoperative pain. Although surgical treatment of chronic posthernioplasty pain is limited because of the lack of relevant research data, resection of entrapped nerves, mesh removal in the case of mesh related pain or removal of fixation sutures can be beneficial for the patient with severe pain after inguinal hernia surgery. One drawback of published studies is the lack of consensus over definition of chronic pain, which makes it complicated to compare the results of different studies and to conduct meta-analyses and systematic reviews. Therefore, a uniform definition of chronic pain and its best assessment methods should be developed in order to conduct top quality multicenter randomized trials. Further research to develop meshes with optimal parameters is of vital importance and should be encouraged.
Fortelny, René H.; Petter-Puchner, Alexander H.; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl
2014-01-01
Background: Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit® mesh by W. L. Gore & Associates. Methods: This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Results: Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Conclusion: Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair. PMID:25593969
Fortelny, René H; Petter-Puchner, Alexander H; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl
2014-01-01
Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit(®) mesh by W. L. Gore & Associates. This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.
NASA Astrophysics Data System (ADS)
Marzec, K.; Kucaba-Pietal, A.
2016-09-01
A series of numerical analysis have been performed to investigate heat transfer characteristics of an impingement cooling array of ten jets directed to the flat surface with different heat flux qw(x). A three-dimensional finite element model was used to solve equations of heat and mass transfer. The study focused on thermal stresses reduction on a cooled surface and aims at answering the question how the Nusselt number distribution on the cooled surface is affected by various inlet flow parameters for different heat flux distributions. The setup consists of a cylindrical plenum with an inline array of ten impingement jets. Simulation has been performed using the Computational Fluid Dynamics (CFD) code Ansys CFX. The k - ω shear stress transport (SST) turbulence model is used in calculations. The numerical analysis of the different mesh density results in good convergence of the GCI index, what excluded mesh size dependency. The physical model is simplified by using the steady state analysis and the incompressible and viscous flow of the fluid.
Carmona, Jesús; Climent, Miguel-Ángel; Antón, Carlos; de Vera, Guillem; Garcés, Pedro
2015-01-01
This article shows the research carried out by the authors focused on how the shape of structural reinforced concrete elements treated with electrochemical chloride extraction can affect the efficiency of this process. Assuming the current use of different anode systems, the present study considers the comparison of results between conventional anodes based on Ti-RuO2 wire mesh and a cement-based anodic system such as a paste of graphite-cement. Reinforced concrete elements of a meter length were molded to serve as laboratory specimens, to closely represent authentic structural supports, with circular and rectangular sections. Results confirm almost equal performances for both types of anode systems when electrochemical chloride extraction is applied to isotropic structural elements. In the case of anisotropic ones, such as rectangular sections with no uniformly distributed rebar, differences in electrical flow density were detected during the treatment. Those differences were more extreme for Ti-RuO2 mesh anode system. This particular shape effect is evidenced by obtaining the efficiencies of electrochemical chloride extraction in different points of specimens.
Performance of a 260 Hz pulse tube cooler with metal fiber as the regenerator material
NASA Astrophysics Data System (ADS)
Wang, Xiaotao; Zhang, Shuang; Yu, Guoyao; Dai, Wei; Luo, Ercang
2014-01-01
Pulse tube coolers operating at higher frequency lead to a high energy density and result in a more compact system. This paper describes the performance of a 300 Hz pulse tube cooler driven by a linear compressor. Such high frequency operation leads to decreased thermal penetration, which requires a smaller hydraulic diameter and smaller wire diameter in the regenerator. In our previous experiments, the stainless steel mesh with a mesh number of 635 was used as the regenerator material, and a no-load temperature of 63 K was obtained. Both the numerical and experimental results indicate this material causes a large loss in the regenerator. A stainless steel fiber regenerator is introduced and studied in this article. Because this fiber has a wide range of wire diameter and porosity, such material might be more suitable for higher frequency pulse tube coolers. With the fiber as the regenerator material and after a series of optimizations, a no-load temperature of 45 K is acquired in the experiment. Influences of various parameters such as frequency and inertance tube length have been investigated experimentally.
Yu, Zeyun; Holst, Michael J.; Hayashi, Takeharu; Bajaj, Chandrajit L.; Ellisman, Mark H.; McCammon, J. Andrew; Hoshijima, Masahiko
2009-01-01
A general framework of image-based geometric processing is presented to bridge the gap between three-dimensional (3D) imaging that provides structural details of a biological system and mathematical simulation where high-quality surface or volumetric meshes are required. A 3D density map is processed in the order of image pre-processing (contrast enhancement and anisotropic filtering), feature extraction (boundary segmentation and skeletonization), and high-quality and realistic surface (triangular) and volumetric (tetrahedral) mesh generation. While the tool-chain described is applicable to general types of 3D imaging data, the performance is demonstrated specifically on membrane-bound organelles in ventricular myocytes that are imaged and reconstructed with electron microscopic (EM) tomography and two-photon microscopy (T-PM). Of particular interest in this study are two types of membrane-bound Ca2+-handling organelles, namely, transverse tubules (T-tubules) and junctional sarcoplasmic reticulum (jSR), both of which play an important role in regulating the excitation-contraction (E-C) coupling through dynamic Ca2+ mobilization in cardiomyocytes. PMID:18835449
Yu, Zeyun; Holst, Michael J; Hayashi, Takeharu; Bajaj, Chandrajit L; Ellisman, Mark H; McCammon, J Andrew; Hoshijima, Masahiko
2008-12-01
A general framework of image-based geometric processing is presented to bridge the gap between three-dimensional (3D) imaging that provides structural details of a biological system and mathematical simulation where high-quality surface or volumetric meshes are required. A 3D density map is processed in the order of image pre-processing (contrast enhancement and anisotropic filtering), feature extraction (boundary segmentation and skeletonization), and high-quality and realistic surface (triangular) and volumetric (tetrahedral) mesh generation. While the tool-chain described is applicable to general types of 3D imaging data, the performance is demonstrated specifically on membrane-bound organelles in ventricular myocytes that are imaged and reconstructed with electron microscopic (EM) tomography and two-photon microscopy (T-PM). Of particular interest in this study are two types of membrane-bound Ca(2+)-handling organelles, namely, transverse tubules (T-tubules) and junctional sarcoplasmic reticulum (jSR), both of which play an important role in regulating the excitation-contraction (E-C) coupling through dynamic Ca(2+) mobilization in cardiomyocytes.
Nava, José L; Sirés, Ignasi; Brillas, Enric
2014-01-01
This paper compares the performance of 2D (plate) and 3D (mesh) boron-doped diamond (BDD) electrodes, fitted into a filter-press reactor, during the electrochemical incineration of indigo textile dye as a model organic compound in chloride medium. The electrolyses were carried out in the FM01-LC reactor at mean fluid velocities between 0.9 ≤ u ≤ 10.4 and 1.2 ≤ u ≤ 13.9 cm s(-1) for the 2D BDD and the 3D BDD electrodes, respectively, at current densities of 5.63 and 15 mA cm(-2). The oxidation of the organic matter was promoted, on the one hand, via the physisorbed hydroxyl radicals (BDD(·OH)) formed from water oxidation at the BDD surface and, on the other hand, via active chlorine formed from the oxidation of chloride ions on BDD. The performance of 2D BDD and 3D BDD electrodes in terms of current efficiency, energy consumption, and charge passage during the treatments is discussed.
2017-01-01
PURPOSE The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr–Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS Glass fiber mesh- and Cr–Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair. PMID:28243388
Huang, Wen-Chen; Yang, Jenn-Ming
2017-03-01
The purpose of this study was to explore the association between mesh location and de novo stress urinary incontinence (SUI) after transvaginal mesh procedures. We retrospectively analyzed a database of women who had received transvaginal mesh procedures for stage III or greater cystocele according to the Pelvic Organ Prolapse Quantification system. Only data for women who neither reported SUI preoperatively nor had received concomitant anti-incontinence surgery were included for analyses. The mesh location was investigated by sonography via the percentage of the urethra covered by mesh, defined as the number calculated by dividing the portion of the urethral length covered by mesh (the distance from the bladder neck to the point of the urethra, which was indicated by an imaginary line at the level of the lower [caudal] mesh end and perpendicular to the urethra) by the total urethral length (the distance from the bladder neck to the external urethral meatus) in the sagittal plane. The resting, straining, coughing, and squeezing mesh locations of women who did (n = 29) and did not (n = 54) report SUI at the 12-month follow-up were compared. At the 12-month follow-up, women who reported SUI had a significantly smaller straining percentage of the urethra covered by mesh (mean ± SD, 28.5% ± 9.6%) compared with continent women (35.2% ± 15.8%), indicating a more proximal straining mesh location. Sonography is useful in investigating the location of the transvaginal mesh. De novo SUI after transvaginal mesh procedures is associated with a more proximal straining mesh location. © 2017 by the American Institute of Ultrasound in Medicine.
Anisotropic evaluation of synthetic surgical meshes.
Saberski, E R; Orenstein, S B; Novitsky, Y W
2011-02-01
The material properties of meshes used in hernia repair contribute to the overall mechanical behavior of the repair. The anisotropic potential of synthetic meshes, representing a difference in material properties (e.g., elasticity) in different material axes, is not well defined to date. Haphazard orientation of anisotropic mesh material can contribute to inconsistent surgical outcomes. We aimed to characterize and compare anisotropic properties of commonly used synthetic meshes. Six different polypropylene (Trelex(®), ProLite™, Ultrapro™), polyester (Parietex™), and PTFE-based (Dualmesh(®), Infinit) synthetic meshes were selected. Longitudinal and transverse axes were defined for each mesh, and samples were cut in each axis orientation. Samples underwent uniaxial tensile testing, from which the elastic modulus (E) in each axis was determined. The degree of anisotropy (λ) was calculated as a logarithmic expression of the ratio between the elastic modulus in each axis. Five of six meshes displayed significant anisotropic behavior. Ultrapro™ and Infinit exhibited approximately 12- and 20-fold differences between perpendicular axes, respectively. Trelex(®), ProLite™, and Parietex™ were 2.3-2.4 times. Dualmesh(®) was the least anisotropic mesh, without marked difference between the axes. Anisotropy of synthetic meshes has been underappreciated. In this study, we found striking differences between elastic properties of perpendicular axes for most commonly used synthetic meshes. Indiscriminate orientation of anisotropic mesh may adversely affect hernia repairs. Proper labeling of all implants by manufacturers should be mandatory. Understanding the specific anisotropic behavior of synthetic meshes should allow surgeons to employ rational implant orientation to maximize outcomes of hernia repair.
Lerdsirisopon, Sopon; Frisella, Margaret M; Matthews, Brent D; Deeken, Corey R
2011-12-01
This study aimed to determine whether the strength and extensibility of hernia repair materials are negatively influenced by the application of helical titanium tacks. This study evaluated 14 meshes including bare polypropylene, macroporous polytetrafluoroethylene, absorbable barrier, partially absorbable mesh, and expanded polytetrafluoroethylene materials. Each mesh provided 15 specimens, which were prepared in 7.5 × 7.5-cm squares. Of these, 5 "undamaged" specimens were subjected to ball-burst testing to determine their biomechanical properties before application of helical titanium tacks (ProTack). To 10 "damaged" specimens 7 tacks were applied 1 cm apart in a 3.5-cm-diameter circle using a tacking force of 25 to 28 N. The tacks were removed from five of the specimens before ball-burst testing and left intact in the remaining five specimens. The application of tacks had no effect on the tensile strength of Dualmesh, ProLite Ultra, Infinit, Ultrapro, C-QUR Lite (<6 in.), Prolene Soft, or Physiomesh, but the tensile strengths were reduced for Bard Mesh, C-QUR, ProLite, and C-QUR Lite (>6 in.). Most of the meshes did not exhibit significantly different tensile strengths between removal of tacks and tacks left intact. Exceptions included C-QUR, Prolene, Ultrapro, and Bard Soft Mesh, which were weaker with removal of tacks than with tacks left intact during the test. Damage due to the application of helical titanium tacks also caused increased strain at a stress of 16 N/cm for all the meshes except C-QUR Lite (>6 in.) and Physiomesh. Many of the meshes evaluated in this study exhibited damage in the form of reduced tensile strength and increased extensibility after the application of tacks compared with the corresponding "undamaged" meshes. Meshes with smaller interstices and larger filaments were influenced negatively by the application of helical titanium tacks, whereas mesh designs with larger interstices and smaller filaments tended to maintain their baseline mechanical properties.
2016-09-01
Hernia formation occurs at closed stoma sites in up to 30% of patients. The Reinforcement of Closure of Stoma Site (ROCSS) randomized controlled trial is evaluating whether placement of biological mesh during stoma closure safely reduces hernia rates compared with closure without mesh, without increasing surgical or wound complications. This paper aims to report recruitment, deliverability and safety from the internal feasibility study. A multicentre, patient and assessor blinded, randomized controlled trial, delivered through surgical trainee research networks. A 90-patient internal feasibility study assessed recruitment, randomization, deliverability and early (30 day) safety of the novel surgical technique (ClinicalTrials.gov registration number NCT02238964). The feasibility study recruited 90 patients from the 104 considered for entry (45 to mesh, 45 to no mesh). Seven of eight participating centres randomized patients within 30 days of opening. Overall, 41% of stomas were created for malignant disease and 73% were ileostomies. No mesh-specific complications occurred. Thirty-one postoperative adverse events were experienced by 31 patients, including surgical site infection (9%) and postoperative ileus (6%). One mesh was removed for re-access to the abdominal cavity, for reasons unrelated to the mesh. Independent review by the Data Monitoring and Ethics Committee of adverse event data by treatment allocation found no safety concerns. Multicentre randomization to this trial of biological mesh is feasible, with no early safety concerns. Progression to the full Phase III trial has continued. ROCSS shows that trainee research networks can efficiently develop and deliver complex interventional surgical trials. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.
NASA Astrophysics Data System (ADS)
Fernandez, D.; Torregrosa, A.; Weiss-Penzias, P. S.; Oliphant, A. J.; Dodge, C.; Bowman, M.; Wilson, S.; Mairs, A. A.; Gravelle, M.; Barkley, T.
2016-12-01
At multiple sites across central CA, several passive fog water collectors have been deployed for the past 3 years. All of the sites employ standard Raschel polypropylene mesh as the fog collection medium and five of them also integrated a novel polypropylene mesh of German manufacture with a 3-dimensional internal structure. Additionally, six metal mesh manufactured by McMaster-Carr of various hole sizing were coated with a POSS-PEMA substance at the Massachusetts Institute of Technology and deployed in parallel with the Raschel mesh at six distinct locations. Finally, fluorine-free versions of the POSS-PEMA substance were generated by NBD Nanotechnology and coated on a much finer mesh substrate. Three of those and one control (uncoated mesh) were deployed at one of the fog collection sites for one season, along with a standard Raschel mesh. Preliminary results from one intercomparison from just one pair of mesh over two seasons seem to reveal a wind speed and also, possibly, a droplet-size dependence on the fog collection efficiency for the mesh. This study will continue to intercompare the various mesh in conjunction with the wind speed and direction data. If a collection efficiency dependence on mesh size or coating is confirmed, it may point to interesting and relevant mechanisms for fog droplet capture and collection hitherto unobserved in field conditions.
Blázquez, Rebeca; Sánchez-Margallo, Francisco Miguel; Álvarez, Verónica; Usón, Alejandra; Casado, Javier G
2016-02-01
Surgical meshes are widely used in clinics to reinforce soft tissue's defects, and to give support to prolapsed organs. However, the implantation of surgical meshes is commonly related with an inflammatory response being difficult to eradicate without removing the mesh. Here we hypothesize that the combined use of surgical meshes and mesenchymal stem cells (MSCs) could be a useful tool to reduce the inflammatory reaction secondary to mesh implantation. In vitro determinations of viability, metabolic activity and immunomodulation assays were performed on MSCs-coated meshes. Magnetic resonance imaging, evaluation by laparoscopic optical system and histology were performed for safety assessment. Finally, flow cytometry and qRT-PCR were used to elucidate the mechanism of action of MSCs-coated meshes. Our results demonstrate the feasibility to obtain MSCs-coated surgical meshes and their cryopreservability to be used as an 'off the shelf' product. These biological meshes fulfill the safety aspects as non-adverse effects were observed when compared to controls. Moreover, both in vitro and in vivo studies demonstrated that, local immunomodulation of implanted meshes is mediated by a macrophage polarization towards an anti-inflammatory phenotype. In conclusion, the combined usage of surgical meshes with MSCs fulfills the safety requirements for a future clinical application, providing an anti-inflammatory environment that could reduce the inflammatory processes commonly observed after surgical mesh implantation. Surgical meshes are medical devices widely used in clinics to resolve hernias and organs' prolapses, among other disorders. However, the implantation of surgical meshes is commonly related with an inflammatory response being difficult to eradicate without removing the mesh, causing pain and discomfort in the patient. Previously, the anti-inflammatory, immunomodulatory and pro-regenerative ability of mesenchymal stem cells (MSCs) have been described. To our knowledge, this is the first report where the anti-inflammatory and pro-regenerative ability of MSCs have been successfully applied in combination with surgical meshes, reducing the inflammatory processes commonly observed after mesh implantation. Moreover, our in vitro and in vivo results highlight the safety and efficacy of these bioactive meshes as a 'ready to use' medical product. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Robust moving mesh algorithms for hybrid stretched meshes: Application to moving boundaries problems
NASA Astrophysics Data System (ADS)
Landry, Jonathan; Soulaïmani, Azzeddine; Luke, Edward; Ben Haj Ali, Amine
2016-12-01
A robust Mesh-Mover Algorithm (MMA) approach is designed to adapt meshes of moving boundaries problems. A new methodology is developed from the best combination of well-known algorithms in order to preserve the quality of initial meshes. In most situations, MMAs distribute mesh deformation while preserving a good mesh quality. However, invalid meshes are generated when the motion is complex and/or involves multiple bodies. After studying a few MMA limitations, we propose the following approach: use the Inverse Distance Weighting (IDW) function to produce the displacement field, then apply the Geometric Element Transformation Method (GETMe) smoothing algorithms to improve the resulting mesh quality, and use an untangler to revert negative elements. The proposed approach has been proven efficient to adapt meshes for various realistic aerodynamic motions: a symmetric wing that has suffered large tip bending and twisting and the high-lift components of a swept wing that has moved to different flight stages. Finally, the fluid flow problem has been solved on meshes that have moved and they have produced results close to experimental ones. However, for situations where moving boundaries are too close to each other, more improvements need to be made or other approaches should be taken, such as an overset grid method.
Three-dimensional analysis of implanted magnetic-resonance-visible meshes.
Sindhwani, Nikhil; Feola, Andrew; De Keyzer, Frederik; Claus, Filip; Callewaert, Geertje; Urbankova, Iva; Ourselin, Sebastien; D'hooge, Jan; Deprest, Jan
2015-10-01
Our primary objective was to develop relevant algorithms for quantification of mesh position and 3D shape in magnetic resonance (MR) images. In this proof-of-principle study, one patient with severe anterior vaginal wall prolapse was implanted with an MR-visible mesh. High-resolution MR images of the pelvis were acquired 6 weeks and 8 months postsurgery. 3D models were created using semiautomatic segmentation techniques. Conformational changes were recorded quantitatively using part-comparison analysis. An ellipticity measure is proposed to record longitudinal conformational changes in the mesh arms. The surface that is the effective reinforcement provided by the mesh is calculated using a novel methodology. The area of this surface is the effective support area (ESA). MR-visible mesh was clearly outlined in the images, which allowed us to longitudinally quantify mesh configuration between 6 weeks and 8 months after implantation. No significant changes were found in mesh position, effective support area, conformation of the mesh's main body, and arm length during the period of observation. Ellipticity profiles show longitudinal conformational changes in posterior arms. This paper proposes novel methodologies for a systematic 3D assessment of the position and morphology of MR-visible meshes. A novel semiautomatic tool was developed to calculate the effective area of support provided by the mesh, a potentially clinically important parameter.
NASA Technical Reports Server (NTRS)
Thompkins, W. T., Jr.
1982-01-01
A FORTRAN-IV computer program was developed for the calculation of the inviscid transonic/supersonic flow field in a fully three dimensional blade passage of an axial compressor rotor or stator. Rotors may have dampers (part span shrouds). MacCormack's explicit time marching method is used to solve the unsteady Euler equations on a finite difference mesh. This technique captures shocks and smears them over several grid points. Input quantities are blade row geometry, operating conditions and thermodynamic quanities. Output quantities are three velocity components, density and internal energy at each mesh point. Other flow quanities are calculated from these variables. A short graphics package is included with the code, and may be used to display the finite difference grid, blade geometry and static pressure contour plots on blade to blade calculation surfaces or blade suction and pressure surfaces. The flow in a low aspect ratio transonic compressor was analyzed and compared with high response total pressure probe measurements and gas fluorescence static density measurements made in the MIT blowdown wind tunnel. These comparisons show that the computed flow fields accurately model the measured shock wave locations and overall aerodynamic performance.
Zero dimensional model of atmospheric SMD discharge and afterglow in humid air
NASA Astrophysics Data System (ADS)
Smith, Ryan; Kemaneci, Efe; Offerhaus, Bjoern; Stapelmann, Katharina; Peter Brinkmann, Ralph
2016-09-01
A novel mesh-like Surface Micro Discharge (SMD) device designed for surface wound treatment is simulated by multiple time-scaled zero-dimensional models. The chemical dynamics of the discharge are resolved in time at atmospheric pressure in humid conditions. Simulated are the particle densities of electrons, 26 ionic species, and 26 reactive neutral species including: O3, NO, and HNO3. The total of 53 described species are constrained by 624 reactions within the simulated plasma discharge volume. The neutral species are allowed to diffuse into a diffusive gas regime which is of primary interest. Two interdependent zero-dimensional models separated by nine orders of magnitude in temporal resolution are used to accomplish this; thereby reducing the computational load. Through variation of control parameters such as: ignition frequency, deposited power density, duty cycle, humidity level, and N2 content, the ideal operation conditions for the SMD device can be predicted. The described model has been verified by matching simulation parameters and comparing results to that of previous works. Current operating conditions of the experimental mesh-like SMD were matched and results are compared to the simulations. Work supported by SFB TR 87.
Evidence-based outcomes for mesh-based surgery for pelvic organ prolapse.
Mettu, Jayadev R; Colaco, Marc; Badlani, Gopal H
2014-07-01
In light of all the recent controversy regarding the use of synthetic mesh for pelvic organ prolapse, we did a retrospective review of the evidence-based outcomes and complications for its use. A total of 18 of the most recent studies in the last 5 years were selected. Studies selected were prospective randomized or quasi-randomized controlled trials that included surgical operations for pelvic organ prolapse for this review. Additionally, Cochrane review and meta-analysis of outcomes and complication were also analyzed. In terms of outcomes, the definition of successful surgery is currently being debated. Synthetic mesh provides superior anatomical and subjective cure rates compared with native tissue repair. Success rates varied greatly depending on the nature of prolapse and surgical approach. Furthermore, recurrence rates for mesh-based surgery are significantly lower than that for native tissue repair. The main unique complication of mesh is exposure and was reported in a mean of 11.4% of patients, with 6.8% of patients requiring surgical partial excision of mesh. Mesh significantly improves anatomical outcomes with sacrocolpopexy and vaginal repair. Mesh does create the unique complication which can be reduced with training and proper patient selection. Further development of better materials is vital rather than reverting to tissue-based repair. Ultimately, the decision to use mesh should be based upon a patient's personal goals and preferences after an informed conversation with her physician.
NO FLARES FROM GAMMA-RAY BURST AFTERGLOW BLAST WAVES ENCOUNTERING SUDDEN CIRCUMBURST DENSITY CHANGE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gat, Ilana; Van Eerten, Hendrik; MacFadyen, Andrew
2013-08-10
Afterglows of gamma-ray bursts are observed to produce light curves with the flux following power-law evolution in time. However, recent observations reveal bright flares at times on the order of minutes to days. One proposed explanation for these flares is the interaction of a relativistic blast wave with a circumburst density transition. In this paper, we model this type of interaction computationally in one and two dimensions, using a relativistic hydrodynamics code with adaptive mesh refinement called RAM, and analytically in one dimension. We simulate a blast wave traveling in a stellar wind environment that encounters a sudden change inmore » density, followed by a homogeneous medium, and compute the observed radiation using a synchrotron model. We show that flares are not observable for an encounter with a sudden density increase, such as a wind termination shock, nor for an encounter with a sudden density decrease. Furthermore, by extending our analysis to two dimensions, we are able to resolve the spreading, collimation, and edge effects of the blast wave as it encounters the change in circumburst medium. In all cases considered in this paper, we find that a flare will not be observed for any of the density changes studied.« less
The impact of stellar feedback on the density and velocity structure of the interstellar medium
NASA Astrophysics Data System (ADS)
Grisdale, Kearn; Agertz, Oscar; Romeo, Alessandro B.; Renaud, Florent; Read, Justin I.
2017-04-01
We study the impact of stellar feedback in shaping the density and velocity structure of neutral hydrogen (H I) in disc galaxies. For our analysis, we carry out ˜4.6 pc resolution N-body+adaptive mesh refinement hydrodynamic simulations of isolated galaxies, set up to mimic a Milky Way and a Large and Small Magellanic Cloud. We quantify the density and velocity structure of the interstellar medium using power spectra and compare the simulated galaxies to observed H I in local spiral galaxies from THINGS (The H I Nearby Galaxy Survey). Our models with stellar feedback give an excellent match to the observed THINGS H I density power spectra. We find that kinetic energy power spectra in feedback-regulated galaxies, regardless of galaxy mass and size, show scalings in excellent agreement with supersonic turbulence (E(k) ∝ k-2) on scales below the thickness of the H I layer. We show that feedback influences the gas density field, and drives gas turbulence, up to large (kpc) scales. This is in stark contrast to density fields generated by large-scale gravity-only driven turbulence. We conclude that the neutral gas content of galaxies carries signatures of stellar feedback on all scales.
Monitoring and evaluation of wire mesh forming life
NASA Astrophysics Data System (ADS)
Enemuoh, Emmanuel U.; Zhao, Ping; Kadlec, Alec
2018-03-01
Forming tables are used with stainless steel wire mesh conveyor belts to produce variety of products. The forming tables will typically run continuously for several days, with some hours of scheduled downtime for maintenance, cleaning and part replacement after several weeks of operation. The wire mesh conveyor belts show large variation in their remaining life due to associated variations in their nominal thicknesses. Currently the industry is dependent on seasoned operators to determine the replacement time for the wire mesh formers. The drawback of this approach is inconsistency in judgements made by different operators and lack of data knowledge that can be used to develop decision making system that will be more consistent with wire mesh life prediction and replacement time. In this study, diagnostic measurements about the health of wire mesh former is investigated and developed. The wire mesh quality characteristics considered are thermal measurement, tension property, gage thickness, and wire mesh wear. The results show that real time thermal sensor and wear measurements would provide suitable data for the estimation of wire mesh failure, therefore, can be used as a diagnostic parameter for developing structural health monitoring (SHM) system for stainless steel wire mesh formers.
Combined synchrotron X-ray tomography and X-ray powder diffraction using a fluorescing metal foil.
Kappen, P; Arhatari, B D; Luu, M B; Balaur, E; Caradoc-Davies, T
2013-06-01
This study realizes the concept of simultaneous micro-X-ray computed tomography and X-ray powder diffraction using a synchrotron beamline. A thin zinc metal foil was placed in the primary, monochromatic synchrotron beam to generate a divergent wave to propagate through the samples of interest onto a CCD detector for tomographic imaging, thus removing the need for large beam illumination and high spatial resolution detection. Both low density materials (kapton tubing and a piece of plant) and higher density materials (Egyptian faience) were investigated, and elemental contrast was explored for the example of Cu and Ni meshes. The viability of parallel powder diffraction using the direct beam transmitted through the foil was demonstrated. The outcomes of this study enable further development of the technique towards in situ tomography∕diffraction studies combining micrometer and crystallographic length scales, and towards elemental contrast imaging and reconstruction methods using well defined fluorescence outputs from combinations of known fluorescence targets (elements).
Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse.
Takazawa, Naoko; Fujisaki, Akiko; Yoshimura, Yasukuni; Tsujimura, Akira; Horie, Shigeo
2018-03-01
This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP). This retrospective cohort study involved 91 women who underwent surgical management of POP with originally designed small mesh between July 2014 and August 2015. This mesh is 56% smaller than the mesh widely used in Japan, and it has only two arms delivered into each right and left sacrospinous ligament. The main study outcome was the anatomic cure rate defined as recurrence of POP quantification (POP-Q) stage II or more. We also assessed changes in the overactive bladder symptom score (OABSS) and prolapse quality of life questionnaire (P-QOL) and evaluated adverse events. Finally, we compared patient backgrounds between the patients with and without recurrence. Prolapse recurred in 10 of 91 patients (11.0%), and all patients with recurrence were diagnosed as POP-Q stage II. As adverse events, only mesh erosion occurred in two (2.2%) and pelvic pain in one (1.1%) of the 91 patients. The OABSS and P-QOL were significantly improved by the operation. When we compared patient backgrounds between the patients with and without recurrence, body mass index was the only factor influencing affecting recurrence. Transvaginal minimal mesh repair resulted in successful outcomes with low mesh-related complications and anatomic recurrence at one year. Furthermore, significant improvement in QOL was offered by this procedure. Our minimal mesh technique should be considered as one treatment option for the management of POP.
Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse
Takazawa, Naoko; Fujisaki, Akiko; Yoshimura, Yasukuni; Tsujimura, Akira
2018-01-01
Purpose This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP). Materials and Methods This retrospective cohort study involved 91 women who underwent surgical management of POP with originally designed small mesh between July 2014 and August 2015. This mesh is 56% smaller than the mesh widely used in Japan, and it has only two arms delivered into each right and left sacrospinous ligament. The main study outcome was the anatomic cure rate defined as recurrence of POP quantification (POP-Q) stage II or more. We also assessed changes in the overactive bladder symptom score (OABSS) and prolapse quality of life questionnaire (P-QOL) and evaluated adverse events. Finally, we compared patient backgrounds between the patients with and without recurrence. Results Prolapse recurred in 10 of 91 patients (11.0%), and all patients with recurrence were diagnosed as POP-Q stage II. As adverse events, only mesh erosion occurred in two (2.2%) and pelvic pain in one (1.1%) of the 91 patients. The OABSS and P-QOL were significantly improved by the operation. When we compared patient backgrounds between the patients with and without recurrence, body mass index was the only factor influencing affecting recurrence. Conclusions Transvaginal minimal mesh repair resulted in successful outcomes with low mesh-related complications and anatomic recurrence at one year. Furthermore, significant improvement in QOL was offered by this procedure. Our minimal mesh technique should be considered as one treatment option for the management of POP. PMID:29520390
Laparoscopic Mesh Fixation Using Laser-Assisted Tissue Soldering in a Porcine Model
Soltz, Barbara A.; Stadler, Istvan; Soltz, Robert
2009-01-01
Background and Objective: Animal studies using open surgical models indicate that collagen solder is capable of fixation of surgical meshes without interfering with tissue integration, increasing adhesions, or increasing inflammation intraperitoneally. This study describes development of instrumentation and techniques for laparoscopic herniorrhaphy using laser-assisted soldering technology. Study Design and Methods: Anesthetized 20 kg to 25 kg female Yorkshire pigs underwent laparoscopy with a 3-trocar technique. Parietex TET, Parietex TEC, and Prolene mesh segments (5 × 5 cm) were embedded in 55% collagen solder. Segments were inserted by using a specially designed introducer and affixed to the peritoneum by using prototype laser devices (1.45 µ, 4.5 W continuous wave, 5-mm spot, 55° C set temperature) and a custom laparoscopic handpiece (IPOM). Parietex PCO mesh was inserted and affixed using the Endo-hernia stapler (Control). Animals were recovered and underwent second-look laparoscopy at 6 weeks. Mesh sites were harvested after animals were euthanized. Results: The mesh-solder constructs were easily inserted and affixed in an IPOM approach. Prolene mesh tended to curl at its edges as the solder was melted. Postoperative healing was similar to that in Control segments in all cases. Discussion and Conclusion: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce the use of staples or other foreign bodies for laparoscopic mesh fixation, prevent tissue ischemia and possibly nerve entrapment, which result in severe postoperative pain and morbidity. Laser-assisted mesh fixation is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted. PMID:19793465
Latent Heat Thermal Energy Storage: Effect of Metallic Mesh Size on Storage Time and Capacity
NASA Astrophysics Data System (ADS)
Shuja, S. Z.; Yilbas, B. S.
2015-11-01
Use of metallic meshes in latent heat thermal storage system shortens the charging time (total melting of the phase change material), which is favorable in practical applications. In the present study, effect of metallic mesh size on the thermal characteristics of latent heat thermal storage system is investigated. Charging time is predicted for various mesh sizes, and the influence of the amount of mesh material on the charging capacity is examined. An experiment is carried out to validate the numerical predictions. It is found that predictions of the thermal characteristics of phase change material with presence of metallic meshes agree well with the experimental data. High conductivity of the metal meshes enables to transfer heat from the edges of the thermal system towards the phase change material while forming a conduction tree in the system. Increasing number of meshes in the thermal system reduces the charging time significantly due to increased rate of conduction heat transfer in the thermal storage system; however, increasing number of meshes lowers the latent heat storage capacity of the system.
NASA Technical Reports Server (NTRS)
Singh, Rajendra; Houser, Donald R.
1993-01-01
This paper discusses analytical and experimental approaches that will be needed to understand dynamic, vibro-acoustic and design characteristics of high power density rotorcraft transmissions. Complexities associated with mathematical modeling of such systems will be discussed. An overview of research work planned during the next several years will be presented, with emphasis on engineering science issues such as gear contact mechanics, multi-mesh drive dynamics, parameter uncertainties, vibration transmission through bearings, and vibro-acoustic characteristics of geared rotor systems and housing-mount structures. A few examples of work in progress are cited.
Calculations for reproducible autologous skin cell-spray grafting.
Esteban-Vives, Roger; Young, Matthew T; Zhu, Toby; Beiriger, Justin; Pekor, Chris; Ziembicki, Jenny; Corcos, Alain; Rubin, Peter; Gerlach, Jörg C
2016-12-01
Non-cultured, autologous cell-spray grafting is an alternative to mesh grafting for larger partial- and deep partial-thickness burn wounds. The treatment uses a suspension of isolated cells, from a patient's donor site skin tissue, and cell-spray deposition onto the wound that facilitates re-epithelialization. Existing protocols for therapeutic autologous skin cell isolation and cell-spray grafting have defined the donor site area to treatment area ratio of 1:80, substantially exceeding the coverage of conventional mesh grafting. However, ratios of 1:100 are possible by maximizing the wound treatment area with harvested cells from a given donor site skin tissue according to a given burn area. Although cell isolation methods are very well described in the literature, a rational approach addressing critical aspects of these techniques are of interest in planning clinical study protocols. We considered in an experimental study the cell yield as a function of the donor site skin tissue, the cell density for spray grafting, the liquid spray volume, the sprayed distribution area, and the percentage of surface coverage. The experimental data was then used for the development of constants and mathematical equations to give a rationale for the cell isolation and cell-spray grafting processes and in planning for clinical studies. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Thin Thermal-Insulation Blankets for Very High Temperatures
NASA Technical Reports Server (NTRS)
Choi, Michael K.
2003-01-01
Thermal-insulation blankets of a proposed type would be exceptionally thin and would endure temperatures up to 2,100 C. These blankets were originally intended to protect components of the NASA Solar Probe spacecraft against radiant heating at its planned closest approach to the Sun (a distance of 4 solar radii). These blankets could also be used on Earth to provide thermal protection in special applications (especially in vacuum chambers) for which conventional thermal-insulation blankets would be too thick or would not perform adequately. A blanket according to the proposal (see figure) would be made of molybdenum, titanium nitride, and carbon- carbon composite mesh, which melt at temperatures of 2,610, 2,930, and 2,130 C, respectively. The emittance of molybdenum is 0.24, while that of titanium nitride is 0.03. Carbon-carbon composite mesh is a thermal insulator. Typically, the blanket would include 0.25-mil (.0.00635-mm)-thick hot-side and cold-side cover layers of molybdenum. Titanium nitride would be vapor-deposited on both surfaces of each cover layer. Between the cover layers there would be 10 inner layers of 0.15-mil (.0.0038-mm)-thick molybdenum with vapor-deposited titanium nitride on both sides of each layer. The thickness of each titanium nitride coat would be about 1,000 A. The cover and inner layers would be interspersed with 0.25-mil (0.00635-mm)-thick layers of carbon-carbon composite mesh. The blanket would have total thickness of 4.75 mils (approximately equal to 0.121 mm) and an areal mass density of 0.7 kilograms per square meter. One could, of course, increase the thermal- insulation capability of the blanket by increasing number of inner layers (thereby unavoidably increasing the total thickness and mass density).
Suture, synthetic, or biologic in contaminated ventral hernia repair.
Bondre, Ioana L; Holihan, Julie L; Askenasy, Erik P; Greenberg, Jacob A; Keith, Jerrod N; Martindale, Robert G; Roth, J Scott; Liang, Mike K
2016-02-01
Data are lacking to support the choice between suture, synthetic mesh, or biologic matrix in contaminated ventral hernia repair (VHR). We hypothesize that in contaminated VHR, suture repair is associated with the lowest rate of surgical site infection (SSI). A multicenter database of all open VHR performed at from 2010-2011 was reviewed. All patients with follow-up of 1 mo and longer were included. The primary outcome was SSI as defined by the Centers for Disease Control and Prevention. The secondary outcome was hernia recurrence (assessed clinically or radiographically). Multivariate analysis (stepwise regression for SSI and Cox proportional hazard model for recurrence) was performed. A total of 761 VHR were reviewed for a median (range) follow-up of 15 (1-50) mo: there were 291(38%) suture, 303 (40%) low-density and/or mid-density synthetic mesh, and 167(22%) biologic matrix repair. On univariate analysis, there were differences in the three groups including ethnicity, ASA, body mass index, institution, diabetes, primary versus incisional hernia, wound class, hernia size, prior VHR, fascial release, skin flaps, and acute repair. The unadjusted outcomes for SSI (15.1%; 17.8%; 21.0%; P = 0.280) and recurrence (17.8%; 13.5%; 21.5%; P = 0.074) were not statistically different between groups. On multivariate analysis, biologic matrix was associated with a nonsignificant reduction in both SSI and recurrences, whereas synthetic mesh associated with fewer recurrences compared to suture (hazard ratio = 0.60; P = 0.015) and nonsignificant increase in SSI. Interval estimates favored biologic matrix repair in contaminated VHR; however, these results were not statistically significant. In the absence of higher level evidence, surgeons should carefully balance risk, cost, and benefits in managing contaminated ventral hernia repair. Copyright © 2016 Elsevier Inc. All rights reserved.
Yousefsani, Seyed Abdolmajid; Shamloo, Amir; Farahmand, Farzam
2018-04-01
A transverse-plane hyperelastic micromechanical model of brain white matter tissue was developed using the embedded element technique (EET). The model consisted of a histology-informed probabilistic distribution of axonal fibers embedded within an extracellular matrix, both described using the generalized Ogden hyperelastic material model. A correcting method, based on the strain energy density function, was formulated to resolve the stiffness redundancy problem of the EET in large deformation regime. The model was then used to predict the homogenized tissue behavior and the associated localized responses of the axonal fibers under quasi-static, transverse, large deformations. Results indicated that with a sufficiently large representative volume element (RVE) and fine mesh, the statistically randomized microstructure implemented in the RVE exhibits directional independency in transverse plane, and the model predictions for the overall and local tissue responses, characterized by the normalized strain energy density and Cauchy and von Mises stresses, are independent from the modeling parameters. Comparison of the responses of the probabilistic model with that of a simple uniform RVE revealed that only the first one is capable of representing the localized behavior of the tissue constituents. The validity test of the model predictions for the corona radiata against experimental data from the literature indicated a very close agreement. In comparison with the conventional direct meshing method, the model provided almost the same results after correcting the stiffness redundancy, however, with much less computational cost and facilitated geometrical modeling, meshing, and boundary conditions imposing. It was concluded that the EET can be used effectively for detailed probabilistic micromechanical modeling of the white matter in order to provide more accurate predictions for the axonal responses, which are of great importance when simulating the brain trauma or tumor growth. Copyright © 2018 Elsevier Ltd. All rights reserved.
Multiphase flow modelling of explosive volcanic eruptions using adaptive unstructured meshes
NASA Astrophysics Data System (ADS)
Jacobs, Christian T.; Collins, Gareth S.; Piggott, Matthew D.; Kramer, Stephan C.
2014-05-01
Explosive volcanic eruptions generate highly energetic plumes of hot gas and ash particles that produce diagnostic deposits and pose an extreme environmental hazard. The formation, dispersion and collapse of these volcanic plumes are complex multiscale processes that are extremely challenging to simulate numerically. Accurate description of particle and droplet aggregation, movement and settling requires a model capable of capturing the dynamics on a range of scales (from cm to km) and a model that can correctly describe the important multiphase interactions that take place. However, even the most advanced models of eruption dynamics to date are restricted by the fixed mesh-based approaches that they employ. The research presented herein describes the development of a compressible multiphase flow model within Fluidity, a combined finite element / control volume computational fluid dynamics (CFD) code, for the study of explosive volcanic eruptions. Fluidity adopts a state-of-the-art adaptive unstructured mesh-based approach to discretise the domain and focus numerical resolution only in areas important to the dynamics, while decreasing resolution where it is not needed as a simulation progresses. This allows the accurate but economical representation of the flow dynamics throughout time, and potentially allows large multi-scale problems to become tractable in complex 3D domains. The multiphase flow model is verified with the method of manufactured solutions, and validated by simulating published gas-solid shock tube experiments and comparing the numerical results against pressure gauge data. The application of the model considers an idealised 7 km by 7 km domain in which the violent eruption of hot gas and volcanic ash high into the atmosphere is simulated. Although the simulations do not correspond to a particular eruption case study, the key flow features observed in a typical explosive eruption event are successfully captured. These include a shock wave resulting from the sudden high-velocity inflow of gas and ash; the formation of a particle-laden plume rising several hundred metres into the atmosphere; the eventual collapse of the plume which generates a volcanic ash fountain and a fast ground-hugging pyroclastic density current; and the growth of a dilute convective region that rises above the ash fountain as a result of buoyancy effects. The results from Fluidity are also compared with results from MFIX, a fixed structured mesh-based multiphase flow code, that uses the same set-up. The key flow features are also captured in MFIX, providing at least some confidence in the plausibility of the numerical results in the absence of quantitative field data. Finally, it is shown by a convergence analysis that Fluidity offers the same solution accuracy for reduced computational cost using an adaptive mesh, compared to the same simulation performed with a uniform fixed mesh.
Bindi, Marco; Rivelli, Matteo; Solej, Mario; Enrico, Stefano; Martino, Valter
2016-01-01
Abstract Laparoscopic transabdominal preperitoneal inguinal hernia repair is a safe and effective technique. In this study we tested the hypothesis that self-gripping mesh used with the laparoscopic approach is comparable to polypropylene mesh in terms of perioperative complications, against a lower overall cost of the procedure. We carried out a prospective randomized trial comparing a group of 30 patients who underwent laparoscopic inguinal hernia repair with self-gripping mesh versus a group of 30 patients who received polypropylene mesh with fibrin glue fixation. There were no statistically significant differences between the two groups with regard to intraoperative variables, early or late intraoperative complications, chronic pain or recurrence. Self-gripping mesh in transabdominal hernia repair was found to be a valid alternative to polypropylene mesh in terms of complications, recurrence and postoperative pain. The cost analysis and comparability of outcomes support the preferential use of self-gripping mesh. PMID:28352842
Zhang, Kun; Han, Jin-song; Zhu, Fu-li; Yao, Ying
2012-09-01
To evaluate the complications after trans-vaginal mesh-augmented pelvic floor reconstruction in treatment of pelvic organ prolapse (POP). From February 2007 to October 2009, vaginal mesh procedures were performed on 91 women with POP stage III-IV in Peking University Third Hospital. The operative complications were studied. Ninety patients underwent successful surgery among 91 patients. Follow-up rate was 94% (85/90) at a median follow-up of 28.4 (15 - 44) months. One patient underwent intraoperative organ injuries, and 10 patients had postoperation mesh-related complications. The rate of mesh-related complications was 2% (2/85), 2% (2/85), 4% (3/85), 4% (3/85) on 6, 6 - 12, 12 - 24 and more than 24 months following up, respectively. Seven patients underwent conservative treatment and the symptoms were improved. Three patients underwent the second surgery, and the symptoms were cured or relieved. The incidence of mesh-related complications was low, and interventions were effective in vaginal mesh procedure.
Reynolds, W Stuart; Gold, Karen P; Ni, Shenghua; Kaufman, Melissa R; Dmochowski, Roger R; Penson, David F
2013-04-01
Prompted by increased reports of complications with the use of mesh for pelvic organ prolapse (POP) surgery, the FDA issued an initial public health notification (PHN) in 2008. We proposed to determine if the numbers of POP cases augmented with surgical mesh performed in U.S. Medicare beneficiaries changed relative to this PHN. Using administrative healthcare claims for beneficiaries enrolled in the U.S. Medicare program from 2008 to 2009, we identified women who underwent POP surgery with and without surgical mesh by procedural and diagnosis coding. In addition to comparing cases with and without mesh, we also calculated rates (number of cases per 100,000 female beneficiaries) and compared these relative to the timing of the PHN. We identified 104,185 POP procedures, of which 27,839 (26.7%) included mesh material and 76,346 (73.3%) did not. Between the last three quarters of 2008 and the first three of 2009, the rates of mesh cases increased (40.3-42.1, P < 0.001) and those without mesh decreased (115.5-111.4, P < 0.001). Inpatient procedures decreased and outpatient procedures increased for both those with and without mesh augmentation. For inpatient procedures, the relative use of biologic graft and synthetic mesh material did not vary over the study period. A substantial number of Medicare beneficiaries underwent mesh POP procedures in 2008-2009. However, despite the PHN cautioning about potential mesh complications, the numbers of mesh cases continued to rise in the immediate period after the PHN. Copyright © 2012 Wiley Periodicals, Inc.
Selective laser vaporization of polypropylene sutures and mesh
NASA Astrophysics Data System (ADS)
Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.
2012-02-01
Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.
A fast solver for the Helmholtz equation based on the generalized multiscale finite-element method
NASA Astrophysics Data System (ADS)
Fu, Shubin; Gao, Kai
2017-11-01
Conventional finite-element methods for solving the acoustic-wave Helmholtz equation in highly heterogeneous media usually require finely discretized mesh to represent the medium property variations with sufficient accuracy. Computational costs for solving the Helmholtz equation can therefore be considerably expensive for complicated and large geological models. Based on the generalized multiscale finite-element theory, we develop a novel continuous Galerkin method to solve the Helmholtz equation in acoustic media with spatially variable velocity and mass density. Instead of using conventional polynomial basis functions, we use multiscale basis functions to form the approximation space on the coarse mesh. The multiscale basis functions are obtained from multiplying the eigenfunctions of a carefully designed local spectral problem with an appropriate multiscale partition of unity. These multiscale basis functions can effectively incorporate the characteristics of heterogeneous media's fine-scale variations, thus enable us to obtain accurate solution to the Helmholtz equation without directly solving the large discrete system formed on the fine mesh. Numerical results show that our new solver can significantly reduce the dimension of the discrete Helmholtz equation system, and can also obviously reduce the computational time.
Elastic Behavior and Platelet Retraction in Low- and High-Density Fibrin Gels
Wufsus, Adam R.; Rana, Kuldeepsinh; Brown, Andrea; Dorgan, John R.; Liberatore, Matthew W.; Neeves, Keith B.
2015-01-01
Fibrin is a biopolymer that gives thrombi the mechanical strength to withstand the forces imparted on them by blood flow. Importantly, fibrin is highly extensible, but strain hardens at low deformation rates. The density of fibrin in clots, especially arterial clots, is higher than that in gels made at plasma concentrations of fibrinogen (3–10 mg/mL), where most rheology studies have been conducted. Our objective in this study was to measure and characterize the elastic regimes of low (3–10 mg/mL) and high (30–100 mg/mL) density fibrin gels using shear and extensional rheology. Confocal microscopy of the gels shows that fiber density increases with fibrinogen concentration. At low strains, fibrin gels act as thermal networks independent of fibrinogen concentration. Within the low-strain regime, one can predict the mesh size of fibrin gels by the elastic modulus using semiflexible polymer theory. Significantly, this provides a link between gel mechanics and interstitial fluid flow. At moderate strains, we find that low-density fibrin gels act as nonaffine mechanical networks and transition to affine mechanical networks with increasing strains within the moderate regime, whereas high-density fibrin gels only act as affine mechanical networks. At high strains, the backbone of individual fibrin fibers stretches for all fibrin gels. Platelets can retract low-density gels by >80% of their initial volumes, but retraction is attenuated in high-density fibrin gels and with decreasing platelet density. Taken together, these results show that the nature of fibrin deformation is a strong function of fibrin fiber density, which has ramifications for the growth, embolization, and lysis of thrombi. PMID:25564864
Porrero, Jose L; Cano-Valderrama, Oscar; Castillo, María J; Marcos, Alberto; Tejerina, Gabriel; Cendrero, Manuel; Porrero, Belén; Alonso, María T; Torres, Antonio J
2018-02-02
importance of mesh overlap on recurrence after open umbilical hernia repair has been poorly studied. a retrospective cohort study was performed with patients who underwent open umbilical hernia repair with bilayer prosthesis between 2004 and 2015. 1538 patients were included. Fifty patients (3.3%) had a mesh overlap lower than 1 cm. After a mean follow-up of 4.1 years 53 patients (3.5%) developed a recurrence. Recurrence was associated with a mesh overlap smaller than 1 cm (10.2% vs. 3.3%, p = 0.010, OR = 3.3). In the logistic regression model an overlap smaller than 1 cm was not statistically associated with recurrence (OR = 2.5, p = 0.123). Female gender, postoperative complications and prosthesis size were associated with hernia recurrence. mesh overlap seems to be an important factor for hernia recurrence. A mesh overlap of at least 1 cm should be used until more studies are performed about this issue. Copyright © 2018 Elsevier Inc. All rights reserved.
Drag Prediction for the DLR-F6 Wing/Body and DPW Wing using CFL3D and OVERFLOW Overset Mesh
NASA Technical Reports Server (NTRS)
Sclanfani, Anthony J.; Vassberg, John C.; Harrison, Neal A.; DeHaan, Mark A.; Rumsey, Christopher L.; Rivers, S. Melissa; Morrison, Joseph H.
2007-01-01
A series of overset grids was generated in response to the 3rd AIAA CFD Drag Prediction Workshop (DPW-III) which preceded the 25th Applied Aerodynamics Conference in June 2006. DPW-III focused on accurate drag prediction for wing/body and wing-alone configurations. The grid series built for each configuration consists of a coarse, medium, fine, and extra-fine mesh. The medium mesh is first constructed using the current state of best practices for overset grid generation. The medium mesh is then coarsened and enhanced by applying a factor of 1.5 to each (I,J,K) dimension. The resulting set of parametrically equivalent grids increase in size by a factor of roughly 3.5 from one level to the next denser level. CFD simulations were performed on the overset grids using two different RANS flow solvers: CFL3D and OVERFLOW. The results were post-processed using Richardson extrapolation to approximate grid converged values of lift, drag, pitching moment, and angle-of-attack at the design condition. This technique appears to work well if the solution does not contain large regions of separated flow (similar to that seen n the DLR-F6 results) and appropriate grid densities are selected. The extra-fine grid data helped to establish asymptotic grid convergence for both the OVERFLOW FX2B wing/body results and the OVERFLOW DPW-W1/W2 wing-alone results. More CFL3D data is needed to establish grid convergence trends. The medium grid was utilized beyond the grid convergence study by running each configuration at several angles-of-attack so drag polars and lift/pitching moment curves could be evaluated. The alpha sweep results are used to compare data across configurations as well as across flow solvers. With the exception of the wing/body drag polar, the two codes compare well qualitatively showing consistent incremental trends and similar wing pressure comparisons.
The numerical simulation study of hemodynamics of the new dense-mesh stent
NASA Astrophysics Data System (ADS)
Ma, Jiali; Yuan, Zhishan; Yu, Xuebao; Feng, Zhaowei; Miao, Weidong; Xu, Xueli; Li, Juntao
2017-09-01
The treatment of aortic aneurysm in new dense mesh stent is based on the principle of hemodynamic changes. But the mechanism is not yet very clear. This paper analyzed and calculated the hemodynamic situation before and after the new dense mesh stent implanting by the method of numerical simulation. The results show the dense mesh stent changed and impacted the blood flow in the aortic aneurysm. The changes include significant decrement of blood velocity, pressure and shear forces, while ensuring blood can supply branches, which means the new dense mesh stent's hemodynamic mechanism in the treatment of aortic aneurysm is clearer. It has very important significance in developing new dense mesh stent in order to cure aortic aneurysm.
NASA Astrophysics Data System (ADS)
Mastracci, Brian; Guo, Wei
2018-01-01
The superfluid phase of helium-4, known as He ii, exhibits extremely small kinematic viscosity and may be a useful tool for economically producing and studying high Reynolds number turbulent flow. Such applications are not currently possible because a comprehensive understanding of the complex two-fluid behavior of He ii is lacking. This situation could be remedied by a systematic investigation of simple, well controlled turbulence that can be directly compared with theoretical models. To this end, we have developed a new apparatus that combines flow visualization with second sound attenuation to study turbulence in the wake of a mesh grid towed through a He ii filled channel. One of three mesh grids (mesh number M = 3, 3.75, or 5 mm) can be pulled at speeds between 0.1 and 60 cm/s through a cast acrylic flow channel which has a 16 mm × 16 mm cross section and measures 330 mm long. The motion of solidified deuterium tracer particles, with diameter of the order 1 μm, in the resulting flow is captured by a high speed camera, and a particle tracking velocimetry algorithm resolves the Lagrangian particle trajectories through the turbulent flow field. A pair of oscillating superleak second sound transducers installed in the channel allows complementary measurement of vortex line density in the superfluid throughout the turbulent decay process. Success in early experiments demonstrates the effectiveness of both probes, and preliminary analysis of the data shows that both measurements strongly correlate with each other. Further investigations will provide comprehensive information that can be used to address open questions about turbulence in He ii and move toward the application of this fluid to high Reynolds number fluid research.
Endogan, T; Ozyaylali, I; Kulacoglu, H; Serbetci, K; Kiyak, G; Hasirci, N
2013-06-01
Prosthetic mesh repair for abdominal wall hernias is widely used because of its technical simplicity and low hernia recurrence rates. The most commonly used material is pure polypropylene mesh, however newer composite materials are recommended by some centers because of their advantages. However, these meshes are more expensive than pure polypropylene meshes. Resterilisation of a pure polypropylene mesh has been shown to be quite safe, and many centers prefer slicing a large mesh into smaller pieces that suitable for hernia type or defect size. Nevertheless there is no data about the safety after resterilisation of the composite meshes. To search the effects of resterilisation and In vitro degradation in phosphate buffered saline solution on the physical structure and the mechanical properties of partially absorbable lightweigth meshes. Laboratory-based research. Two composite meshes were used in the study: One mesh is consisted of monofilament polypropylene and monofilament polyglecaprone--a copolymer of glycolide and epsilon (ε)-caprolactone--(Ultrapro®, 28 g/m2, Ethicon, Hamburg, Germany),andthe otherone consisted of multifilamentpolypropyleneandmultifilament polyglactine (Vypro II®, 30 g/m2,Ethicon, Hamburg, Germany). Two large meshes were cut into rectangular specimens sized 50x20 mm for mechanical testing and 20x20 mm for In vitro degradation experiments. Meshes were divided into control group with no resterilisation and gas resterilisation. Ethylene oxide gas sterilisation was performed at 55°C for 4.5 hours. In vitro degradation in 0.01 M phosphate buffered saline (PBS, pH 7.4) solution at 37 ± 1°C for 8 weeks was applied to one subgroup in each mesh group. Tensiometric measurements and scanning electron microscopyic evaluations were completed for control and resterilisation specimens. Regardless of resterilisation, when meshes were exposed to In vitro degradation, all mechanical parameters decreased significantly. Highest reduction in mechanical properties was observed for Ultrapro due to the degradation of absorbable polyglecaprone and polyglactin parts of these meshes. It was observed that resterilisation by ethylene oxide did not have significant difference on the degradation characteristics and almost similar physical structures were observed for resterilised and non-resterilised meshes. For Vypro II meshes, no significant mechanical difference was observedbetweenresterilised andnon-resterilised meshes after degradationwhile resterilised Ultrapro meshes exhibited stronger characteristics than non-resterilised counterparts, after degradation. Resterilisation with ethylene oxide did not affect the mechanical properties of partially absorbable composite meshes. No important surface changeswere observed in scanning electron microscopy after resterilisation.
N-body simulations for f(R) gravity using a self-adaptive particle-mesh code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao Gongbo; Koyama, Kazuya; Li Baojiu
2011-02-15
We perform high-resolution N-body simulations for f(R) gravity based on a self-adaptive particle-mesh code MLAPM. The chameleon mechanism that recovers general relativity on small scales is fully taken into account by self-consistently solving the nonlinear equation for the scalar field. We independently confirm the previous simulation results, including the matter power spectrum, halo mass function, and density profiles, obtained by Oyaizu et al.[Phys. Rev. D 78, 123524 (2008)] and Schmidt et al.[Phys. Rev. D 79, 083518 (2009)], and extend the resolution up to k{approx}20 h/Mpc for the measurement of the matter power spectrum. Based on our simulation results, we discussmore » how the chameleon mechanism affects the clustering of dark matter and halos on full nonlinear scales.« less
On the electromagnetic scattering from infinite rectangular grids with finite conductivity
NASA Technical Reports Server (NTRS)
Christodoulou, C. G.; Kauffman, J. F.
1986-01-01
A variety of methods can be used in constructing solutions to the problem of mesh scattering. However, each of these methods has certain drawbacks. The present paper is concerned with a new technique which is valid for all spacings. The new method involved, called the fast Fourier transform-conjugate gradient method (FFT-CGM), represents an iterative technique which employs the conjugate gradient method to improve upon each iterate, utilizing the fast Fourier transform. The FFT-CGM method provides a new accurate model which can be extended and applied to the more difficult problems of woven mesh surfaces. The formulation of the FFT-conjugate gradient method for aperture fields and current densities for a planar periodic structure is considered along with singular operators, the formulation of the FFT-CG method for thin wires with finite conductivity, and reflection coefficients.
NASA Astrophysics Data System (ADS)
Zimkowski, Michael M.
About 600,000 hernia repair surgeries are performed each year. The use of laparoscopic minimally invasive techniques has become increasingly popular in these operations. Use of surgical mesh in hernia repair has shown lower recurrence rates compared to other repair methods. However in many procedures, placement of surgical mesh can be challenging and even complicate the procedure, potentially leading to lengthy operating times. Various techniques have been attempted to improve mesh placement, including use of specialized systems to orient the mesh into a specific shape, with limited success and acceptance. In this work, a programmed novel Shape Memory Polymer (SMP) was integrated into commercially available polyester surgical meshes to add automatic unrolling and tissue conforming functionalities, while preserving the intrinsic structural properties of the original surgical mesh. Tensile testing and Dynamic Mechanical Analysis was performed on four different SMP formulas to identify appropriate mechanical properties for surgical mesh integration. In vitro testing involved monitoring the time required for a modified surgical mesh to deploy in a 37°C water bath. An acute porcine model was used to test the in vivo unrolling of SMP integrated surgical meshes. The SMP-integrated surgical meshes produced an automated, temperature activated, controlled deployment of surgical mesh on the order of several seconds, via laparoscopy in the animal model. A 30 day chronic rat model was used to test initial in vivo subcutaneous biocompatibility. To produce large more clinical relevant sizes of mesh, a mold was developed to facilitate manufacturing of SMP-integrated surgical mesh. The mold is capable of manufacturing mesh up to 361 cm2, which is believed to accommodate the majority of clinical cases. Results indicate surgical mesh modified with SMP is capable of laparoscopic deployment in vivo, activated by body temperature, and possesses the necessary strength and biocompatibility to function as suitable ventral hernia repair mesh, while offering a reduction in surgical operating time and improving mesh placement characteristics. Future work will include ball-burst tests similar to ASTM D3787-07, direct surgeon feedback studies, and a 30 day chronic porcine model to evaluate the SMP surgical mesh in a realistic hernia repair environment, using laparoscopic techniques for typical ventral hernia repair.
Gondal, Mohammed A; Sadullah, Muhammad S; Dastageer, Mohamed A; McKinley, Gareth H; Panchanathan, Divya; Varanasi, Kripa K
2014-08-27
Surfaces which possess extraordinary water attraction or repellency depend on surface energy, surface chemistry, and nano- and microscale surface roughness. Synergistic superhydrophilic-underwater superoleophobic surfaces were fabricated by spray deposition of nanostructured TiO2 on stainless steel mesh substrates. The coated meshes were then used to study gravity driven oil-water separation, where only the water from the oil-water mixture is allowed to permeate through the mesh. Oil-water separation efficiencies of up to 99% could be achieved through the coated mesh of pore sizes 50 and 100 μm, compared to no separation at all, that was observed in the case of uncoated meshes of the same material and pore sizes. An adsorbed water on the TiO2 coated surface, formation of a water-film between the wires that form the mesh and the underwater superoleophobicity of the structured surface are the key factors that contribute to the enhanced efficiency observed in oil-water separation. The nature of the oil-water separation process using this coated mesh (in which the mesh allows water to pass through the porous structure but resists wetting by the oil phase) minimizes the fouling of mesh so that the need for frequent replacement of the separating medium is reduced. The fabrication approach presented here can be applied for coating large surface areas and to develop a large-scale oil-water separation facility for oil-field applications and petroleum industries.
Ventral hernia repair with poly-4-hydroxybutyrate mesh.
Plymale, Margaret A; Davenport, Daniel L; Dugan, Adam; Zachem, Amanda; Roth, John Scott
2018-04-01
Biomaterial research has made available a biologically derived fully resorbable poly-4-hydroxybutyrate (P4HB) mesh for use in ventral and incisional hernia repair (VIHR). This study evaluates outcomes of patients undergoing VIHR with P4HB mesh. An IRB-approved prospective pilot study was conducted to assess clinical and quality of life (QOL) outcomes for patients undergoing VIHR with P4HB mesh. Perioperative characteristics were defined. Clinical outcomes, employment status, QOL using 12-item short form survey (SF-12), and pain assessments were followed for 24 months postoperatively. 31 patients underwent VIHR with bioresorbable mesh via a Rives-Stoppa approach with retrorectus mesh placement. The median patient age was 52 years, median body mass index was 33 kg/m 2 , and just over half of the patients were female. Surgical site occurrences occurred in 19% of patients, most of which were seroma. Hernia recurrence rate was 0% (median follow-up = 414 days). Patients had significantly improved QOL at 24 months compared to baseline for SF-12 physical component summary and role emotional (p < 0.05). Ventral hernia repair with P4HB bioresorbable mesh results in favorable outcomes. Early hernia recurrence was not identified among the patient cohort. Quality of life improvements were noted at 24 months versus baseline for this cohort of patients with bioresorbable mesh. Use of P4HB mesh for ventral hernia repair was found to be feasible in this patient population. (ClinicalTrials.gov Identifier: NCT01863030).
Macrophage polarization in response to ECM coated polypropylene mesh
Wolf, MT; Dearth, CL; Ranallo, CA; LoPresti, S; Carey, LE; Daly, KA; Brown, BN; Badylak, SF
2015-01-01
The host response to implanted biomaterials is a highly regulated process that influences device functionality and clinical outcome. Non-degradable biomaterials, such as knitted polypropylene mesh, frequently elicit a chronic foreign body reaction with resultant fibrosis. Previous studies have shown that an extracellular matrix (ECM) hydrogel coating of polypropylene mesh reduces the intensity of the foreign body reaction, though the mode of action is unknown. Macrophage participation plays a key role in the development of the foreign body reaction to biomaterials, and therefore the present study investigated macrophage polarization following mesh implantation. Spatiotemporal analysis of macrophage polarization was conducted in response to uncoated polypropylene mesh and mesh coated with hydrated and dry forms of ECM hydrogels derived from either dermis or urinary bladder. Pro-inflammatory M1 macrophages (CD86+/CD68+), alternatively activated M2 macrophages (CD206+/CD68+), and foreign body giant cells were quantified between 3-35 days. Uncoated polypropylene mesh elicited a dominant M1 response at the mesh fiber surface, which was decreased by each ECM coating type beginning at 7 days. The diminished M1 response was accompanied by a reduction in the number of foreign body giant cells at 14 and 35 days, though there was a minimal effect upon the number of M2 macrophages at any time. These results show that ECM coatings attenuate the M1 macrophage response and increase the M2/M1 ratio to polypropylene mesh in vivo. PMID:24856104
Laparoscopic mesh fixation using laser-assisted tissue soldering in a porcine model.
Lanzafame, Raymond J; Soltz, Barbara A; Stadler, Istvan; Soltz, Robert
2009-01-01
Animal studies using open surgical models indicate that collagen solder is capable of fixation of surgical meshes without interfering with tissue integration, increasing adhesions, or increasing inflammation intraperitoneally. This study describes development of instrumentation and techniques for laparoscopic herniorrhaphy using laser-assisted soldering technology. Anesthetized 20 kg to 25 kg female Yorkshire pigs underwent laparoscopy with a 3-trocar technique. Parietex TET, Parietex TEC, and Prolene mesh segments (5 x 5 cm) were embedded in 55% collagen solder. Segments were inserted by using a specially designed introducer and affixed to the peritoneum by using prototype laser devices (1.45 micro, 4.5 W continuous wave, 5-mm spot, 55 degrees C set temperature) and a custom laparoscopic handpiece (IPOM). Parietex PCO mesh was inserted and affixed using the Endo-hernia stapler (Control). Animals were recovered and underwent second-look laparoscopy at 6 weeks. Mesh sites were harvested after animals were euthanized. The mesh-solder constructs were easily inserted and affixed in an IPOM approach. Prolene mesh tended to curl at its edges as the solder was melted. Postoperative healing was similar to that in Control segments in all cases. Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce the use of staples or other foreign bodies for laparoscopic mesh fixation, prevent tissue ischemia and possibly nerve entrapment, which result in severe postoperative pain and morbidity. Laser-assisted mesh fixation is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted.
Abbott, Sara; Unger, Cecile A; Evans, Janelle M; Jallad, Karl; Mishra, Kevita; Karram, Mickey M; Iglesia, Cheryl B; Rardin, Charles R; Barber, Matthew D
2014-02-01
The purpose of this study was to describe the evaluation and management of synthetic mesh-related complications after surgery for stress urinary incontinence (SUI) and/or pelvic organ prolapse (POP). We conducted a multicenter, retrospective analysis of women who attended 4 US tertiary referral centers for evaluation of mesh-related complications after surgery for SUI and/or POP from January 2006 to December 2010. Demographic, clinical, and surgical data were abstracted from the medical record, and complications were classified according to the Expanded Accordion Severity Classification. Three hundred forty-seven patients sought management of synthetic mesh-related complications over the study period. Index surgeries were performed for the following indications: SUI (sling only), 49.9%; POP (transvaginal mesh [TVM] or sacrocolpopexy only), 25.6%; and SUI + POP (sling + TVM or sacrocolpopexy), 24.2%. Median time to evaluation was 5.8 months (range, 0-65.2). Thirty percent of the patients had dyspareunia; 42.7% of the patients had mesh erosion; and 34.6% of the patients had pelvic pain. Seventy-seven percent of the patients had a grade 3 or 4 (severe) complication. Patients with TVM or sacrocolpopexy were more likely to have mesh erosion and vaginal symptoms compared with sling only. The median number of treatments for mesh complications was 2 (range, 1-9); 60% of the women required ≥2 interventions. Initial treatment intervention was surgical for 49% of subjects. Of those treatments that initially were managed nonsurgically, 59.3% went on to surgical intervention. Most of the women who seek management of synthetic mesh complication after POP or SUI surgery have severe complications that require surgical intervention; a significant proportion require >1 surgical procedure. The pattern of complaints differs by index procedure. Copyright © 2014 Mosby, Inc. All rights reserved.
Effect of Codend Circumference on the Size Selection of Square-Mesh Codends in Trawl Fisheries
De Carlo, Francesco; Lucchetti, Alessandro
2016-01-01
It is well established that increasing mesh number in the circumference of a diamond-mesh trawl codend can reduce size selection for round fish, whereas selection for flat fish species is unaffected. This effect has also been documented in Mediterranean trawl fisheries. In contrast, no information is available with regard to the effect of increasing mesh number in the circumference of square-mesh codends on the size selection of round fish and flat fish species. A field study was devised to bridge this gap and formulate proposals aimed at improving trawl fishery management. Size selection data were collected for a round fish species, red mullet (Mullus barbatus), and two flat fish species, Mediterranean scaldfish (Arnoglossus laterna) and solenette (Buglossidium luteum). Fishing trials were conducted in the Adriatic Sea (Central Mediterranean) using three square-mesh codends that differed only in mesh number around the circumference. Results demonstrated that increasing the number of meshes from 107 to 213 reduced the 50% retention length (L50) for red mullet by 2.5 cm but did not affect size selection for the two flat fish species. In some fisheries, regulatory provisions regarding the number of meshes in the circumference should therefore be carefully considered both for diamond- and square-mesh codends. PMID:27472058
Calculation methods study on hot spot stress of new girder structure detail
NASA Astrophysics Data System (ADS)
Liao, Ping; Zhao, Renda; Jia, Yi; Wei, Xing
2017-10-01
To study modeling calculation methods of new girder structure detail's hot spot stress, based on surface extrapolation method among hot spot stress method, a few finite element analysis models of this welded detail were established by finite element software ANSYS. The influence of element type, mesh density, different local modeling methods of the weld toe and extrapolation methods was analyzed on hot spot stress calculation results at the toe of welds. The results show that the difference of the normal stress in the thickness direction and the surface direction among different models is larger when the distance from the weld toe is smaller. When the distance from the toe is greater than 0.5t, the normal stress of solid models, shell models with welds and non-weld shell models tends to be consistent along the surface direction. Therefore, it is recommended that the extrapolated point should be selected outside the 0.5t for new girder welded detail. According to the results of the calculation and analysis, shell models have good grid stability, and extrapolated hot spot stress of solid models is smaller than that of shell models. So it is suggested that formula 2 and solid45 should be carried out during the hot spot stress extrapolation calculation of this welded detail. For each finite element model under different shell modeling methods, the results calculated by formula 2 are smaller than those of the other two methods, and the results of shell models with welds are the largest. Under the same local mesh density, the extrapolated hot spot stress decreases gradually with the increase of the number of layers in the thickness direction of the main plate, and the variation range is within 7.5%.
NASA Astrophysics Data System (ADS)
Haakonsen, Christian Bernt; Hutchinson, Ian H.
2013-10-01
Mach probes can be used to measure transverse flow in magnetized plasmas, but what they actually measure in strongly non-uniform plasmas has not been definitively established. A fluid treatment in previous work has suggested that the diamagnetic drifts associated with background density and temperature gradients affect transverse flow measurements, but detailed computational study is required to validate and elaborate on those results; it is really a kinetic problem, since the probe deforms and introduces voids in the ion and electron distribution functions. A new code, the Plasma-Object Simulator with Iterated Trajectories (POSIT) has been developed to self-consistently compute the steady-state six-dimensional ion and electron distribution functions in the perturbed plasma. Particle trajectories are integrated backwards in time to the domain boundary, where arbitrary background distribution functions can be specified. This allows POSIT to compute the ion and electron density at each node of its unstructured mesh, update the potential based on those densities, and then iterate until convergence. POSIT is used to study the impact of a background density gradient on transverse Mach probe measurements, and the results compared to the previous fluid theory. C.B. Haakonsen was supported in part by NSF/DOE Grant No. DE-FG02-06ER54512, and in part by an SCGF award administered by ORISE under DOE Contract No. DE-AC05-06OR23100.
Improvement of finite element meshes - Heat transfer in an infinite cylinder
NASA Technical Reports Server (NTRS)
Kittur, Madan G.; Huston, Ronald L.; Oswald, Fred B.
1989-01-01
An extension of a structural finite element mesh improvement technique to heat conduction analysis is presented. The mesh improvement concept was originally presented by Prager in studying tapered, axially loaded bars. It was further shown that an improved mesh can be obtained by minimizing the trace of the stiffnes matrix. These procedures are extended and applied to the analysis of heat conduction in an infinitely long hollow circular cylinder.
Improvement in finite element meshes: Heat transfer in an infinite cylinder
NASA Technical Reports Server (NTRS)
Kittur, Madan G.; Huston, Ronald L.; Oswald, Fred B.
1988-01-01
An extension of a structural finite element mesh improvement technique to heat conduction analysis is presented. The mesh improvement concept was originally presented by Prager in studying tapered, axially loaded bars. It was further shown that an improved mesh can be obtained by minimizing the trace of the stiffness matrix. These procedures are extended and applied to the analysis of heat conduction in an infinitely long hollow circular cylinder.
Dong, Zhiyong; Kujawa, Stacy Ann; Wang, Cunchuan; Zhao, Hong
2018-04-23
The aim of this study was to systematically review the available clinical trials examining male infertility after inguinal hernias were repaired using mesh procedures. The Cochrane Library, PubMed, Embase, Web of Science, and Chinese Biomedical Medicine Database were investigated. The Jada score was used to evaluate the quality of the studies, "Oxford Centre for Evidence-based Medicine-Levels of Evidence" was used to assess the level of the trials, and descriptive analysis was used to evaluate the studies. Twenty nine related trials with a total of 36,552 patients were investigated, including seven randomized controlled trials (RCTs) with 616 patients and 10 clinical trials (1230 patients) with mesh or non-mesh repairs. The Jada score showed that there were six high quality RCTs and one low quality RCT. Levels of evidence determined from the Oxford Centre for Evidence-based Medicine further demonstrated that those six high quality RCTs also had high levels of evidence. It was found that serum testosterone, LH, and FSH levels declined in the laparoscopic group compared to the open group; however, the testicular volume only slightly increased without statistical significance. Testicular and sexual functions remained unchanged after both laparoscopic transabdominal preperitoneal hernia repair (TAPP) and totally extra-peritoneal repair (TEP). We also compared the different meshes used post-surgeries. VyproII/Timesh lightweight mesh had a diminished effect on sperm motility compared to Marlex heavyweight mesh after a one-year follow-up, but there was no effect after 3 years. Additionally, various open hernia repair procedures (Lichtenstein, mesh plug method, posterior pre-peritoneal mesh repair, and anterior tension-free repair) did not cause infertility. This systematic review suggests that hernia repair with mesh either in an open or a laparoscopic procedure has no significant effect on male fertility.
NASA Astrophysics Data System (ADS)
Wang, Wan-Sheng; Xiang, Yuan-Yuan; Wang, Qiang-Hua; Wang, Fa; Yang, Fan; Lee, Dung-Hai
2012-01-01
We study the electronic instabilities of near 1/4 electron doped graphene using the singular-mode functional renormalization group, with a self-adaptive k mesh to improve the treatment of the van Hove singularities, and variational Monte Carlo method. At 1/4 doping the system is a chiral spin-density wave state exhibiting the anomalous quantized Hall effect. When the doping deviates from 1/4, the dx2-y2+idxy Cooper pairing becomes the leading instability. Our results suggest that near 1/4 electron or hole doping (away from the neutral point) the graphene is either a Chern insulator or a topoligical superconductor.
Adaptive grid methods for RLV environment assessment and nozzle analysis
NASA Technical Reports Server (NTRS)
Thornburg, Hugh J.
1996-01-01
Rapid access to highly accurate data about complex configurations is needed for multi-disciplinary optimization and design. In order to efficiently meet these requirements a closer coupling between the analysis algorithms and the discretization process is needed. In some cases, such as free surface, temporally varying geometries, and fluid structure interaction, the need is unavoidable. In other cases the need is to rapidly generate and modify high quality grids. Techniques such as unstructured and/or solution-adaptive methods can be used to speed the grid generation process and to automatically cluster mesh points in regions of interest. Global features of the flow can be significantly affected by isolated regions of inadequately resolved flow. These regions may not exhibit high gradients and can be difficult to detect. Thus excessive resolution in certain regions does not necessarily increase the accuracy of the overall solution. Several approaches have been employed for both structured and unstructured grid adaption. The most widely used involve grid point redistribution, local grid point enrichment/derefinement or local modification of the actual flow solver. However, the success of any one of these methods ultimately depends on the feature detection algorithm used to determine solution domain regions which require a fine mesh for their accurate representation. Typically, weight functions are constructed to mimic the local truncation error and may require substantial user input. Most problems of engineering interest involve multi-block grids and widely disparate length scales. Hence, it is desirable that the adaptive grid feature detection algorithm be developed to recognize flow structures of different type as well as differing intensity, and adequately address scaling and normalization across blocks. These weight functions can then be used to construct blending functions for algebraic redistribution, interpolation functions for unstructured grid generation, forcing functions to attract/repel points in an elliptic system, or to trigger local refinement, based upon application of an equidistribution principle. The popularity of solution-adaptive techniques is growing in tandem with unstructured methods. The difficultly of precisely controlling mesh densities and orientations with current unstructured grid generation systems has driven the use of solution-adaptive meshing. Use of derivatives of density or pressure are widely used for construction of such weight functions, and have been proven very successful for inviscid flows with shocks. However, less success has been realized for flowfields with viscous layers, vortices or shocks of disparate strength. It is difficult to maintain the appropriate mesh point spacing in the various regions which require a fine spacing for adequate resolution. Mesh points often migrate from important regions due to refinement of dominant features. An example of this is the well know tendency of adaptive methods to increase the resolution of shocks in the flowfield around airfoils, but in the incorrect location due to inadequate resolution of the stagnation region. This problem has been the motivation for this research.
da Rosa, Fernando William Figueiredo; Pohl, Pedro Henrique Isoldi; Mader, Ana Maria Amaral Antônio; de Paiva, Carla Peluso; dos Santos, Aline Amaro; Bianco, Bianca; Rodrigues, Luciano Miller Reis
2015-01-01
ABSTRACT Objective To evaluate inflammatory reaction, fibrosis and neovascularization in dural repairs in Wistar rats using four techniques: simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Methods Thirty Wistar rats were randomized in five groups: the first was the control group, submitted to dural tear only. The others underwent durotomy and simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Animals were euthanized and the spine was submitted to histological evaluation with a score system (ranging from zero to 3) for inflammation, neovascularization and fibrosis. Results Fibrosis was significantly different between simple suture and silicon mesh (p=0.005) and between simple suture and mesh with suture (p=0.015), showing that fibrosis is more intense when a foreign body is used in the repair. Bovine membrane was significantly different from mesh plus suture (p=0.011) regarding vascularization. Inflammation was significantly different between simple suture and bovine collagen membrane. Conclusion Silicon mesh, compared to other commercial products available, is a possible alternative for dural repair. More studies are necessary to confirm these findings. PMID:26761555
Koo, Kevin; Gormley, E Ann
2017-02-01
Prompted by patients' changing perceptions of transvaginal mesh, this study examines how mesh has been reported in the news following the 2011 US Food and Drug Administration (FDA) updated notification about the use of mesh in the treatment of pelvic organ prolapse. Two national newspaper databases were queried for articles discussing transvaginal mesh published within 3 years of the FDA announcement. Content analysis included headline subjects, mesh-related complications, quoted sources, and the FDA recommendations. To determine whether more widely read sources publish higher quality reporting, a subgroup analysis was conducted based on newspaper circulation. Ninety-five articles met inclusion criteria. Mesh-related litigation was the most common headline subject (36 articles, 38%), and 54% of all articles referenced legal action. Fifty-seven articles (60%) cited at least one mesh-related complication. Only 18 articles (19%) quoted surgeons who use transvaginal mesh. For the FDA update, 40% of articles that first reported the announcement accurately specified that it applies to mesh for prolapse, not incontinence. This ambiguity persisted: half of all articles cited the warning, but only 23% distinguished between prolapse and incontinence. Higher newspaper circulation did not significantly improve the quality of reporting about the content or context of the FDA's recommendations. Despite frequent media coverage of transvaginal mesh and its complications since 2011, very few news sources that cited the FDA warning distinguished between prolapse and incontinence. Given prevalent reporting of mesh-related litigation, the findings raise concern about how patients perceive the safety and efficacy of transvaginal mesh, regardless of indication. Neurourol. Urodynam. 36:329-332, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
RICH: OPEN-SOURCE HYDRODYNAMIC SIMULATION ON A MOVING VORONOI MESH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yalinewich, Almog; Steinberg, Elad; Sari, Re’em
2015-02-01
We present here RICH, a state-of-the-art two-dimensional hydrodynamic code based on Godunov’s method, on an unstructured moving mesh (the acronym stands for Racah Institute Computational Hydrodynamics). This code is largely based on the code AREPO. It differs from AREPO in the interpolation and time-advancement schemeS as well as a novel parallelization scheme based on Voronoi tessellation. Using our code, we study the pros and cons of a moving mesh (in comparison to a static mesh). We also compare its accuracy to other codes. Specifically, we show that our implementation of external sources and time-advancement scheme is more accurate and robustmore » than is AREPO when the mesh is allowed to move. We performed a parameter study of the cell rounding mechanism (Lloyd iterations) and its effects. We find that in most cases a moving mesh gives better results than a static mesh, but it is not universally true. In the case where matter moves in one way and a sound wave is traveling in the other way (such that relative to the grid the wave is not moving) a static mesh gives better results than a moving mesh. We perform an analytic analysis for finite difference schemes that reveals that a Lagrangian simulation is better than a Eulerian simulation in the case of a highly supersonic flow. Moreover, we show that Voronoi-based moving mesh schemes suffer from an error, which is resolution independent, due to inconsistencies between the flux calculation and the change in the area of a cell. Our code is publicly available as open source and designed in an object-oriented, user-friendly way that facilitates incorporation of new algorithms and physical processes.« less
Bona, Stefano; Rosati, Riccardo; Opocher, Enrico; Fiore, Barbara; Montorsi, Marco
2018-03-01
Mesh repair has significantly reduced recurrence rate after groin hernia surgery. Recently, attention has shifted to issues such as chronic pain and discomfort, leading to development of lightweight and partially re-absorbable meshes. The aim of the study was to evaluate the effect of lightweight mesh vs heavyweight mesh on post-operative pain, discomfort and quality of life in short and medium term after inguinal hernia surgery. Eight hundred and eight patients with primary inguinal hernia were allocated to anterior repair (Lichtenstein technique) using a lightweight mesh (Ultrapro ® ) or a heavyweight mesh (Prolene ® ). Primary outcomes were incidence of chronic pain and discomfort at 6-month follow-up. Secondary endpoints were quality of life (QoL), pain and complication at 1 week, 1 and 6 months. At 6 months, 25% of patients reported pain of some intensity; severe pain was reported by 1% of patients in both groups. A statistically significant difference in favour of lightweight mesh was found at multivariable analysis for pain (1 week and 6 months after surgery: p = 0.02 and p = 0.04, respectively) and QoL at 1 month and 6 months (p = 0.05 and p = 0.02, respectively). There was no difference in complication rate and no hernia recurrences were detected. The use of lightweight mesh in anterior Lichtenstein inguinal hernia repair significantly reduced the incidence of pain and favourably affected the perceived quality of life at 6 months after surgery compared to heavyweight mesh.
NASA Astrophysics Data System (ADS)
Zaini, H.; Abubakar, S.; Rihayat, T.; Suryani, S.
2018-03-01
Removal of heavy metal content in wastewater has been largely done by various methods. One effective and efficient method is the adsorption method. This study aims to reduce manganese (II) content in wastewater based on column adsorption method using absorbent material from bagasse. The fixed variable consisted of 50 g adsorbent, 10 liter adsorbate volume, flow rate of 7 liters / min. Independent variable of particle size with variation 10 – 30 mesh and contact time with variation 0 - 240 min and respon variable concentration of adsorbate (ppm), pH and conductivity. The results showed that the adsorption process of manganese metal is influenced by particle size and contact time. The adsorption kinetics takes place according to pseudo-second order kinetics with an equilibrium adsorption capacity (qe: mg / g) for 10 mesh adsorbent particles: 0.8947; 20 mesh adsorbent particles: 0.4332 and 30 mesh adsorbent particles: 1.0161, respectively. Highest removal efficience for 10 mesh adsorbent particles: 49.22% on contact time 60 min; 20 mesh adsorbent particles: 35,25% on contact time 180 min and particle 30 mesh adsorbent particles: 51,95% on contact time 150 min.
Wolf, Matthew T.; Carruthers, Christopher A.; Dearth, Christopher L.; Crapo, Peter M.; Huber, Alexander; Burnsed, Olivia A.; Londono, Ricardo; Johnson, Scott A.; Daly, Kerry A.; Stahl, Elizabeth C.; Freund, John M.; Medberry, Christopher J.; Carey, Lisa E.; Nieponice, Alejandro; Amoroso, Nicholas J.; Badylak, Stephen F.
2013-01-01
Surgical mesh devices composed of synthetic materials are commonly used for ventral hernia repair. These materials provide robust mechanical strength and are quickly incorporated into host tissue; factors which contribute to reduced hernia recurrence rates. However, such mesh devices cause a foreign body response with the associated complications of fibrosis and patient discomfort. In contrast, surgical mesh devices composed of naturally occurring extracellular matrix (ECM) are associated with constructive tissue remodeling, but lack the mechanical strength of synthetic materials. A method for applying a porcine dermal ECM hydrogel coating to a polypropylene mesh is described herein with the associated effects upon the host tissue response and biaxial mechanical behavior. Uncoated and ECM coated heavy-weight BARD™ Mesh were compared to the light-weight ULTRAPRO™ and BARD™ Soft Mesh devices in a rat partial thickness abdominal defect overlay model. The ECM coated mesh attenuated the pro-inflammatory response compared to all other devices, with a reduced cell accumulation and fewer foreign body giant cells. The ECM coating degraded by 35 days, and was replaced with loose connective tissue compared to the dense collagenous tissue associated with the uncoated polypropylene mesh device. Biaxial mechanical characterization showed that all of the mesh devices were of similar isotropic stiffness. Upon explantation, the light-weight mesh devices were more compliant than the coated or uncoated heavy-weight devices. The present study shows that an ECM coating alters the default host response to a polypropylene mesh, but not the mechanical properties in an acute in vivo abdominal repair model. PMID:23873846
Multiple-relaxation-time lattice Boltzmann method for immiscible fluids at high Reynolds numbers.
Fakhari, Abbas; Lee, Taehun
2013-02-01
The lattice Boltzmann method for immiscible multiphase flows with large density ratio is extended to high Reynolds number flows using a multiple-relaxation-time (MRT) collision operator, and its stability and accuracy are assessed by simulating the Kelvin-Helmholtz instability. The MRT model is successful at damping high-frequency oscillations in the kinetic energy emerging from traveling waves generated by the inclusion of curvature. Numerical results are shown to be in good agreement with prior studies using adaptive mesh refinement techniques applied to the Navier-Stokes equations. Effects of viscosity and surface tension, as well as density ratio, are investigated in terms of the Reynolds and Weber numbers. It is shown that increasing the Reynolds number results in a more chaotic interface evolution and eventually shattering of the interface, while surface tension is shown to have a stabilizing effect.
Histologic Inflammatory Response to Transvaginal Polypropylene Mesh: A Systematic Review.
Thomas, Dominique; Demetres, Michelle; Anger, Jennifer T; Chughtai, Bilal
2018-01-01
To evaluate the inflammatory response following transvaginal implantation of polypropylene (PP) mesh. A comprehensive literature search was performed in the following databases from inception in April 2017: Ovid MEDLINE, Ovid EMBASE, and The Cochrane Library (Wiley). The studies retrieved were screened for eligibility against predefined inclusion and exclusion criteria. Twenty-three articles were included in this review. Following the implantation of PP mesh, there are immediate and local inflammatory responses. PP mesh elicits an inflammatory response that decreases over time; however, no studies documented a complete resolution. Further studies are needed to determine if there is a complete resolution of inflammation or if it persists. Copyright © 2017 Elsevier Inc. All rights reserved.
Fortelny, René H; Hofmann, Anna; May, Christopher; Köckerling, Ferdinand
2016-01-01
Although recently published guidelines recommend against the use of synthetic non-absorbable materials in cases of potentially contaminated or contaminated surgical fields due to the increased risk of infection (1, 2), the use of bio-prosthetic meshes for abdominal wall or ventral hernia repair is still controversially discussed in such cases. Bio-prosthetic meshes have been recommended due to less susceptibility for infection and the decreased risk of subsequent mesh explantation. The purpose of this review is to elucidate if there are any indications for the use of biological and biosynthetic meshes in incarcerated abdominal wall hernias based on the recently published literature. A literature search of the Medline database using the PubMed search engine, using the keywords returned 486 articles up to June 2015. The full text of 486 articles was assessed and 13 relevant papers were identified including 5 retrospective case cohort studies, 2 case-controlled studies, and 6 case series. The results of Franklin et al. (3-5) included the highest number of biological mesh repairs (Surgisis(®)) by laparoscopic IPOM in infected fields, which demonstrated a very low incidence of infection and recurrence (0.7 and 5.2%). Han et al. (6) reported in his retrospective study, the highest number of treated patients due to incarcerated hernias by open approach using acellular dermal matrix (ADM(®)) with very low rate of infection as well as recurrences (1.6 and 15.9%). Both studies achieved acceptable outcome in a follow-up of at least 3.5 years compared to the use of synthetic mesh in this high-risk population (7). Currently, there is a very limited evidence for the use of biological and biosynthetic meshes in strangulated hernias in either open or laparo-endoscopic repair. Finally, there is an urgent need to start with randomized controlled comparative trials as well as to support registries with data to achieve more knowledge for tailored indication for the use of biological meshes.
A tuned mesh-generation strategy for image representation based on data-dependent triangulation.
Li, Ping; Adams, Michael D
2013-05-01
A mesh-generation framework for image representation based on data-dependent triangulation is proposed. The proposed framework is a modified version of the frameworks of Rippa and Garland and Heckbert that facilitates the development of more effective mesh-generation methods. As the proposed framework has several free parameters, the effects of different choices of these parameters on mesh quality are studied, leading to the recommendation of a particular set of choices for these parameters. A mesh-generation method is then introduced that employs the proposed framework with these best parameter choices. This method is demonstrated to produce meshes of higher quality (both in terms of squared error and subjectively) than those generated by several competing approaches, at a relatively modest computational and memory cost.
Christoffersen, M W; Helgstrand, F; Rosenberg, J; Kehlet, H; Bisgaard, T
2013-11-01
Repair for a small (≤ 2 cm) umbilical and epigastric hernia is a minor surgical procedure. The most common surgical repair techniques are a sutured repair or a repair with mesh reinforcement. However, the optimal repair technique with regard to risk of reoperation for recurrence is not well documented. The aim of the present study was in a nationwide setup to investigate the reoperation rate for recurrence after small open umbilical and epigastric hernia repairs using either sutured or mesh repair. This was a prospective cohort study based on intraoperative registrations from the Danish Ventral Hernia Database (DVHD) of patients undergoing elective open mesh and sutured repair for small (≤ 2 cm) umbilical and epigastric hernias. Patients were included during a 4-year study period. A complete follow-up was obtained by combining intraoperative data from the DVHD with data from the Danish National Patient Register. The cumulative reoperation rates were obtained using cumulative incidence plot and compared with the log rank test. In total, 4,786 small (≤ 2 cm) elective open umbilical and epigastric hernia repairs were included. Age was median 48 years (range 18-95 years). Follow-up was 21 months (range 0-47 months). The cumulated reoperation rates for recurrence were 2.2 % for mesh reinforcement and 5.6 % for sutured repair (P = 0.001). The overall cumulated reoperation rate for sutured and mesh repairs was 4.8 %. In conclusion, reoperation rate for recurrence for small umbilical and epigastric hernias was significantly lower after mesh repair compared with sutured repair. Mesh reinforcement should be routine in even small umbilical or epigastric hernias to lower the risk of reoperation for recurrence avoid recurrence.
Finite Element in Angle Unit Sphere Meshing for Charged Particle Transport.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ortega, Mario Ivan; Drumm, Clifton R.
Finite element in angle formulations of the charged particle transport equation require the discretization of the unit sphere. In Sceptre, a three-dimensional surface mesh of a sphere is transformed into a two-dimensional mesh. Projection of a sphere onto a two-dimensional surface is well studied with map makers spending the last few centuries attempting to create maps that preserve proportion and area. Using these techniques, various meshing schemes for the unit sphere were investigated.
Mesh for prolapse surgery: Why the fuss?
Rajshekhar, Smita; Mukhopadhyay, Sambit; Klinge, Uwe
2015-06-01
Pelvic organ prolapse is a common gynaecological problem. Surgical techniques to repair prolapse have been constantly evolving to reduce the recurrence of prolapse and need for reoperation. Grafts made of synthetic and biological materials became popular in the last decade as they were intended to provide extra support to native tissue repairs. However, serious complications related to use of synthetic meshes have been reported and there is increasing medico-legal concern about mesh use in prolapse surgery. Some mesh products already have been withdrawn from the market and the FDA has introduced stricter surveillance of new and existing products. Large randomized studies comparing mesh with non-mesh procedures are lacking which creates uncertainty for the surgeon and their patients.The small cohorts of the RCTs available with short follow-up periods just allow the conclusion that the mesh repair can be helpful in the short to medium term but unfortunately are not able to prove safety for all patients. In particular, current clinical reports cannot define for which indication what material may be superior compared to non-mesh repair.Quality control through long-term individual and national mesh registries is needed to keep a record of all surgeons using mesh and all devices being used, monitoring their effectiveness and safety data. Meshes with better biocompatibility designed specifically for use in vaginal surgery may provide superior clinical results, where the reduction of complications may allow a wider range of indications. © The Author(s) 2015.
Hernández-Gascón, B; Peña, E; Melero, H; Pascual, G; Doblaré, M; Ginebra, M P; Bellón, J M; Calvo, B
2011-11-01
The material properties of meshes used in hernia surgery contribute to the overall mechanical behaviour of the repaired abdominal wall. The mechanical response of a surgical mesh has to be defined since the haphazard orientation of an anisotropic mesh can lead to inconsistent surgical outcomes. This study was designed to characterize the mechanical behaviour of three surgical meshes (Surgipro®, Optilene® and Infinit®) and to describe a mechanical constitutive law that accurately reproduces the experimental results. Finally, through finite element simulation, the behaviour of the abdominal wall was modelled before and after surgical mesh implant. Uniaxial loading of mesh samples in two perpendicular directions revealed the isotropic response of Surgipro® and the anisotropic behaviour of Optilene® and Infinit®. A phenomenological constitutive law was used to reproduce the measured experimental curves. To analyze the mechanical effect of the meshes once implanted in the abdomen, finite element simulation of the healthy and partially herniated repaired rabbit abdominal wall served to reproduce wall behaviour before and after mesh implant. In all cases, maximal displacements were lower and maximal principal stresses higher in the implanted abdomen than the intact wall model. Despite the fact that no mesh showed a behaviour that perfectly matched that of abdominal muscle, the Infinit® mesh was able to best comply with the biomechanics of the abdominal wall. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Melman, L; Jenkins, E D; Hamilton, N A; Bender, L C; Brodt, M D; Deeken, C R; Greco, S C; Frisella, M M; Matthews, B D
2011-04-01
Biologic meshes have unique physical properties as a result of manufacturing techniques such as decellularization, crosslinking, and sterilization. The purpose of this study is to directly compare the biocompatibility profiles of five different biologic meshes, AlloDerm(®) (non-crosslinked human dermal matrix), PeriGuard(®) (crosslinked bovine pericardium), Permacol(®) (crosslinked porcine dermal matrix), Strattice(®) (non-crosslinked porcine dermal matrix), and Veritas(®) (non-crosslinked bovine pericardium), using a porcine model of ventral hernia repair. Full-thickness fascial defects were created in 20 Yucatan minipigs and repaired with the retromuscular placement of biologic mesh 3 weeks later. Animals were euthanized at 1 month and the repair sites were subjected to tensile testing and histologic analysis. Samples of unimplanted (de novo) meshes and native porcine abdominal wall were also analyzed for their mechanical properties. There were no significant differences in the biomechanical characteristics between any of the mesh-repaired sites at 1 month postimplantation or between the native porcine abdominal wall without implanted mesh and the mesh-repaired sites (P > 0.05 for all comparisons). Histologically, non-crosslinked materials exhibited greater cellular infiltration, extracellular matrix (ECM) deposition, and neovascularization compared to crosslinked meshes. While crosslinking differentiates biologic meshes with regard to cellular infiltration, ECM deposition, scaffold degradation, and neovascularization, the integrity and strength of the repair site at 1 month is not significantly impacted by crosslinking or by the de novo strength/stiffness of the mesh.
Shultz, Mary
2006-01-01
Introduction: Given the common use of acronyms and initialisms in the health sciences, searchers may be entering these abbreviated terms rather than full phrases when searching online systems. The purpose of this study is to evaluate how various MEDLINE Medical Subject Headings (MeSH) interfaces map acronyms and initialisms to the MeSH vocabulary. Methods: The interfaces used in this study were: the PubMed MeSH database, the PubMed Automatic Term Mapping feature, the NLM Gateway Term Finder, and Ovid MEDLINE. Acronyms and initialisms were randomly selected from 2 print sources. The test data set included 415 randomly selected acronyms and initialisms whose related meanings were found to be MeSH terms. Each acronym and initialism was entered into each MEDLINE MeSH interface to determine if it mapped to the corresponding MeSH term. Separately, 46 commonly used acronyms and initialisms were tested. Results: While performance differed widely, the success rates were low across all interfaces for the randomly selected terms. The common acronyms and initialisms tested at higher success rates across the interfaces, but the differences between the interfaces remained. Conclusion: Online interfaces do not always map medical acronyms and initialisms to their corresponding MeSH phrases. This may lead to inaccurate results and missed information if acronyms and initialisms are used in search strategies. PMID:17082832
Grubnik, Vladimir V; Grubnik, Aleksandra V; Vorotyntseva, Kseniya O
2014-06-01
Laparoscopic incisional and ventral hernia repair (LIVHR) was first reported by Le Blanc and Booth in 1993. Many studies are available in the literature that have shown that laparoscopic repair of incisional and ventral hernia is preferred over open repair because of lower recurrence rates (less than 10%), less wound morbidity, less pain, and early return to work. To identify the long-term outcomes between the different types of meshes and two techniques of mesh fixation, i.e., tacks (method Double crown) and transfascial polypropylene sutures. A total of 92 patients underwent LIVHR at our department between January 2009 and August 2012. The hernias were umbilical in 26 patients, paraumbilical in 15 patients and incisional in 51 patients. All patients admitted for LIVHR were randomized to either group I (tacker fixation of ePTFE meshes) or group II (suture fixation of meshes with nitinol frame) using computer-generated random numbers with block randomization and sealed envelopes for concealed allocation. The mean mesh fixation time was significantly higher in the tacker fixation group (117 ±15 min vs. 72 ±6 min, p < 0.01). There were no conversions in either group. The median postoperative hospital stay was 3.5 ±1.5 days. All patients were followed up at 1, 3, 6, 12 and every 6 months thereafter postoperatively. There were 5 recurrences in the study population. In group I there were 4 patients with recurrence, and only 1 patient in the group with meshes with a nitinol frame. Meshes of the new generation with a nitinol framework can significantly improve laparoscopic ventral hernia repair. The fixation of these meshes is very simple using 3-4 transfascial sutures. The absence of shrinkage of these meshes makes the probability of recurrence minimal. Absence of tackers allows postoperative pain to be minimized. We consider that these new meshes can significantly improve laparoscopic ventral hernia repair.
Liu, Yu; Zhang, Zhongkai; Lei, Jiuhou; Cao, Jinxiang; Yu, Pengcheng; Zhang, Xiao; Xu, Liang; Zhao, Yaodong
2016-09-01
In this work, the design and construction of the Keda Space Plasma EXperiment (KSPEX), which aims to study the boundary layer processes of ionospheric depletions, are described in detail. The device is composed of three stainless-steel sections: two source chambers at both ends and an experimental chamber in the center. KSPEX is a steady state experimental device, in which hot filament arrays are used to produce plasmas in the two sources. A Macor-mesh design is adopted to adjust the plasma density and potential difference between the two plasmas, which creates a boundary layer with a controllable electron density gradient and inhomogeneous radial electric field. In addition, attachment chemicals can be released into the plasmas through a tailor-made needle valve which leads to the generation of negative ions plasmas. Ionospheric depletions can be modeled and simulated using KSPEX, and many micro-physical processes of the formation and evolution of an ionospheric depletion can be experimentally studied.
Tan, Jiubin; Lu, Zhengang
2007-02-05
This paper presents the experimental study on an inductive mesh composed of contiguous metallic rings fabricated using UV-lithography on quartz glass. Experimental results indicate that, at the same period and linewidth as square mesh, ring mesh has better transmissivity for its higher obscuration ratio, stronger electromagnetic shielding performance for its smaller maximum aperture, and less degradation of imaging quality for its lower ratio and uniform distribution of high order diffraction energy. It is therefore concluded that this kind of ring mesh can be used as high-pass filters to provide electromagnetic shielding of optical transparent elements.
Jaffee, B A
2004-09-01
Soil cages (polyvinyl chloride pipe with mesh-covered ends) were used to determine how the quantity of two organic amendments affected the nematode-trapping fungi Dactylellina haptotyla and Arthrobotrys oligospora, which were studied independently in two different vineyards. Each cage contained 80 cm(3) of field soil (120 g dry weight equivalent), fungal inoculum (two alginate pellets, each weighing 1.9 mg and containing assimilative hyphae of one fungus), and dried grape or alfalfa leaves (0, 360, or 720 mg equivalent to 0, 4,500, or 9,000 kg/ha) with a C:N of 28:1 and 8:1, respectively. Cages were buried in the vineyards, recovered after 25 to 39 days, and returned to the laboratory where fungus population density and trapping were quantified. Dactylellina haptotyla population density and trapping were most enhanced by the smaller quantity of alfalfa amendment and were not enhanced by the larger quantity of alfalfa amendment. Arthrobotrys oligospora population density was most enhanced by the larger quantity of alfalfa amendment, but A. oligospora trapped few or no nematodes, regardless of amendment. Trapping and population density were correlated for D. haptotyla but not for A. oligospora.
[Development of better tolerated prosthetic materials: applications in gynecological surgery].
Debodinance, P; Delporte, P; Engrand, J B; Boulogne, M
2002-10-01
Meshes have come to be widely used for surgical repair of the dysfunctional pelvic floor. The problem to date has been mesh intolerance. History. The first meshes were made with silver filigrees or stainless steel. Non-metallic and non-absorbable synthetic prostheses include nylon, silastic, polytetrafluoroethylene as well as expansive polyester and polypropylene forms. Most of the absorbable prostheses are made of polyglycolic acid and polyglactine 910. Classification. Four groups of biomaterials can be described according to pore size. Mechanical and biological properties. The mechanical properties of meshes have been tested industrially for resistance, pliability, elasticity and ductile qualities. These properties depend on type of tissue structure (woven or knitted) and the type of fiber used (mono and multi-filaments). The goal is to obtain a "silent" material, i.e. a material which does not trigger a host tissue reaction. Introducing the foreign body induces a "scarring" response. This fibroblastic reaction replaces the inflammatory reaction, leading to progressive colonization of the prosthesis. The major risk is infection caused by a disturbance of the inflammatory phase and bacterial development. Bacteria can be trapped in fibrotic tissue, with the risk of delayed infection. Immunological reactions may have an additive effect. These problems are not encountered with absorbable meshes. An ideal implant material must: not undergo physical modification by tissue fluids, be chemically inert, not trigger inflammatory or foreign body cell response in body tissues, be noncarcinogenic and nonallergenic, be capable of resisting mechanical stress and sterilization, and be able to be manufactured in the necessary shape. Polyester, polypropylene and expansive polytetrafluoroethylene fulfill these criteria. The ideal mesh. Eleven criteria are proposed. Complications for hernia repair. Infection and seroma are the most frequent complications with micro-porous meshes. Macro-porous meshes can cause erosive phenomena and adhesions. Retraction of synthetic tissues is observed in 20 to 30% of cases. Meshes in gynecology. In gynecology surgery, meshes made their first appearance in trans-abdominal sacrocolpopexy and slings. A detailed review of complications found in 32 articles studying slings and 22 studying sacrocolpopexy with approximately 10 types of meshes shows that intolerance of slings has oscillated between 1% with Prolene and 31% with Gore-Tex; for abdominal sacrocolpopexy the rate was between 1.7% with Prolene and 20% with Teflon. Rejection phenomena appear during the first year and are proportional to the surface area of the synthetic tissue and the proximity of the vaginal scar. New materials have been proposed over the last ten years for prolapse surgery, notably for cystocele, which accounts for 70% of all repair procedures. Nearly fifteen studies have reported a level of intolerance reaching 6%, the large majority of the meshes used being Prolene meshes. Our personal experience with 87 repair procedures has led us to the conclusion that Prolene is the most adapted mesh, allowing free tension between the bladder and the anterior vaginal wall. Continuous evaluation is needed to study these replacement materials which should in theory, improve the rate of recurrence, which is at present 20% with classic procedures not using a mesh.
Syringe-Injectable Electronics with a Plug-and-Play Input/Output Interface.
Schuhmann, Thomas G; Yao, Jun; Hong, Guosong; Fu, Tian-Ming; Lieber, Charles M
2017-09-13
Syringe-injectable mesh electronics represent a new paradigm for brain science and neural prosthetics by virtue of the stable seamless integration of the electronics with neural tissues, a consequence of the macroporous mesh electronics structure with all size features similar to or less than individual neurons and tissue-like flexibility. These same properties, however, make input/output (I/O) connection to measurement electronics challenging, and work to-date has required methods that could be difficult to implement by the life sciences community. Here we present a new syringe-injectable mesh electronics design with plug-and-play I/O interfacing that is rapid, scalable, and user-friendly to nonexperts. The basic design tapers the ultraflexible mesh electronics to a narrow stem that routes all of the device/electrode interconnects to I/O pads that are inserted into a standard zero insertion force (ZIF) connector. Studies show that the entire plug-and-play mesh electronics can be delivered through capillary needles with precise targeting using microliter-scale injection volumes similar to the standard mesh electronics design. Electrical characterization of mesh electronics containing platinum (Pt) electrodes and silicon (Si) nanowire field-effect transistors (NW-FETs) demonstrates the ability to interface arbitrary devices with a contact resistance of only 3 Ω. Finally, in vivo injection into mice required only minutes for I/O connection and yielded expected local field potential (LFP) recordings from a compact head-stage compatible with chronic studies. Our results substantially lower barriers for use by new investigators and open the door for increasingly sophisticated and multifunctional mesh electronics designs for both basic and translational studies.
Kassem, M I; El-Haddad, H M
2016-10-01
To compare polypropylene mesh positioned onlay supported by omentum and/or peritoneum versus inlay implantation of polypropylene-based composite mesh in patients with complicated wide-defect ventral hernias. This was a prospective randomized study carried out on 60 patients presenting with complicated large ventral hernia in the period from January 2012 to January 2016 in the department of Gastrointestinal Surgery unit and Surgical Emergency of the Main Alexandria University Hospital, Egypt. Large hernia had an abdominal wall defect that could not be closed. Patients were divided into two groups of 30 patients according to the type of mesh used to deal with the large abdominal wall defect. The study included 38 women (63.3 %) and 22 men (37.7 %); their mean age was 46.5 years (range, 25-70). Complicated incisional hernia was the commonest presentation (56.7 %).The operative and mesh fixation times were longer in the polypropylene group. Seven wound infections and two recurrences were encountered in the propylene group. Mean follow-up was 28.7 months (2-48 months). Composite mesh provided, in one session, satisfactory results in patients with complicated large ventral hernia. The procedure is safe and effective in lowering operative time with a trend of low wound complication and recurrence rates.
Li, Na; Hu, Yi; Lu, Yong-Ze; Zeng, Raymond J; Sheng, Guo-Ping
2016-07-01
In the recent years, anaerobic membrane bioreactor (AnMBR) technology is being considered as a very attractive alternative for wastewater treatment due to the striking advantages such as upgraded effluent quality. However, fouling control is still a problem for the application of AnMBR. This study investigated the performance of an AnMBR using mesh filter as support material to treat low-strength wastewater via in-situ biogas sparging. It was found that mesh AnMBR exhibited high and stable chemical oxygen demand (COD) removal efficiencies with values of 95 ± 5 % and an average methane yield of 0.24 L CH4/g CODremoved. Variation of transmembrane pressure (TMP) during operation indicated that mesh fouling was mitigated by in-situ biogas sparging and the fouling rate was comparable to that of aerobic membrane bioreactor with mesh filter reported in previous researches. The fouling layer formed on the mesh exhibited non-uniform structure; the porosity became larger from bottom layer to top layer. Biogas sparging could not change the composition but make thinner thickness of cake layer, which might be benefit for reducing membrane fouling rate. It was also found that ultrasonic cleaning of fouled mesh was able to remove most foulants on the surface or pores. This study demonstrated that in-situ biogas sparging enhanced the performance of AnMBRs with mesh filter in low-strength wastewater treatment. Apparently, AnMBRs with mesh filter can be used as a promising and sustainable technology for wastewater treatment.
Knight, Katrina M; Moalli, Pamela A; Abramowitch, Steven D
2018-05-01
Pelvic organ prolapse (POP) meshes are exposed to predominately tensile loading conditions in vivo that can lead to pore collapse by 70-90%, decreasing overall porosity and providing a plausible mechanism for the contraction/shrinkage of mesh observed following implantation. To prevent pore collapse, we proposed to design synthetic meshes with a macrostructure that results in auxetic behavior, the pores expand laterally, instead of contracting when loaded. Such behavior can be achieved with a range of auxetic structures/geometries. This study utilized finite element analysis (FEA) to assess the behavior of mesh models with eight auxetic pore geometries subjected to uniaxial loading to evaluate their potential to allow for pore expansion while simultaneously providing resistance to tensile loading. Overall, substituting auxetic geometries for standard pore geometries yielded more pore expansion, but often at the expense of increased model elongation, with two of the eight auxetics not able to maintain pore expansion at higher levels of tension. Meshes with stable pore geometries that remain open with loading will afford the ingrowth of host tissue into the pores and improved integration of the mesh. Given the demonstrated ability of auxetic geometries to allow for pore size maintenance (and pore expansion), auxetically designed meshes have the potential to significantly impact surgical outcomes and decrease the likelihood of major mesh-related complications.
Nguyen, Thuy-Duong Thi; Bae, Tae-Sung; Yang, Dae-hyeok; Park, Myung-sik; Yoon, Sun-jung
2017-01-01
The management of severe acetabular bone defects in revision reconstructive orthopedic surgery is challenging. In this study, cyclic precalcification (CP) treatment was used on both nanotube-surface Ti-mesh and a bone graft substitute for the acetabular defect model, and its effects were assessed in vitro and in vivo. Nanotube-Ti mesh coated with hydroxyapatite/β-tricalcium phosphate (HA/β-TCP) was manufactured by an anodizing and a sintering method, respectively. An 8 mm diameter defect was created on each acetabulum of eight rabbits, then treated by grafting materials and covered by Ti meshes. At four and eight weeks, postoperatively, biopsies were performed for histomorphometric analyses. The newly-formed bone layers under cyclic precalcified anodized Ti (CP-AT) meshes were superior with regard to the mineralized area at both four and eight weeks, as compared with that under untreated Ti meshes. Active bone regeneration at 2–4 weeks was stronger than at 6–8 weeks, particularly with treated biphasic ceramic (p < 0.05). CP improved the bioactivity of Ti meshes and biphasic grafting materials. Moreover, the precalcified nanotubular Ti meshes could enhance early contact bone formation on the mesh and, therefore, may reduce the collapse of Ti meshes into the defect, increasing the sufficiency of acetabular reconstruction. Finally, cyclic precalcification did not affect bone regeneration by biphasic grafting materials in vivo. PMID:28686210
Ghaffari, Mahsa; Tangen, Kevin; Alaraj, Ali; Du, Xinjian; Charbel, Fady T; Linninger, Andreas A
2017-12-01
In this paper, we present a novel technique for automatic parametric mesh generation of subject-specific cerebral arterial trees. This technique generates high-quality and anatomically accurate computational meshes for fast blood flow simulations extending the scope of 3D vascular modeling to a large portion of cerebral arterial trees. For this purpose, a parametric meshing procedure was developed to automatically decompose the vascular skeleton, extract geometric features and generate hexahedral meshes using a body-fitted coordinate system that optimally follows the vascular network topology. To validate the anatomical accuracy of the reconstructed vasculature, we performed statistical analysis to quantify the alignment between parametric meshes and raw vascular images using receiver operating characteristic curve. Geometric accuracy evaluation showed an agreement with area under the curves value of 0.87 between the constructed mesh and raw MRA data sets. Parametric meshing yielded on-average, 36.6% and 21.7% orthogonal and equiangular skew quality improvement over the unstructured tetrahedral meshes. The parametric meshing and processing pipeline constitutes an automated technique to reconstruct and simulate blood flow throughout a large portion of the cerebral arterial tree down to the level of pial vessels. This study is the first step towards fast large-scale subject-specific hemodynamic analysis for clinical applications. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Miyoshi, T.; Teramura, T.; Ruiz, J.; Kondo, K.; Lien, G. Y.
2016-12-01
Convective weather is known to be highly nonlinear and chaotic, and it is hard to predict their location and timing precisely. Our Big Data Assimilation (BDA) effort has been exploring to use dense and frequent observations to avoid non-Gaussian probability density function (PDF) and to apply an ensemble Kalman filter under the Gaussian error assumption. The phased array weather radar (PAWR) can observe a dense three-dimensional volume scan with 100-m range resolution and 100 elevation angles in only 30 seconds. The BDA system assimilates the PAWR reflectivity and Doppler velocity observations every 30 seconds into 100 ensemble members of storm-scale numerical weather prediction (NWP) model at 100-m grid spacing. The 30-second-update, 100-m-mesh BDA system has been quite successful in multiple case studies of local severe rainfall events. However, with 1000 ensemble members, the reduced-resolution BDA system at 1-km grid spacing showed significant non-Gaussian PDF with every-30-second updates. With a 10240-member ensemble Kalman filter with a global NWP model at 112-km grid spacing, we found roughly 1000 members satisfactory to capture the non-Gaussian error structures. With these in mind, we explore how the density of observations in space and time affects the non-Gaussianity in an ensemble Kalman filter with a simple toy model. In this presentation, we will present the most up-to-date results of the BDA research, as well as the investigation with the toy model on the non-Gaussianity with dense and frequent observations.
Multi-dimensional multi-species modeling of transient electrodeposition in LIGA microfabrication.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Gregory Herbert; Chen, Ken Shuang
2004-06-01
This report documents the efforts and accomplishments of the LIGA electrodeposition modeling project which was headed by the ASCI Materials and Physics Modeling Program. A multi-dimensional framework based on GOMA was developed for modeling time-dependent diffusion and migration of multiple charged species in a dilute electrolyte solution with reduction electro-chemical reactions on moving deposition surfaces. By combining the species mass conservation equations with the electroneutrality constraint, a Poisson equation that explicitly describes the electrolyte potential was derived. The set of coupled, nonlinear equations governing species transport, electric potential, velocity, hydrodynamic pressure, and mesh motion were solved in GOMA, using themore » finite-element method and a fully-coupled implicit solution scheme via Newton's method. By treating the finite-element mesh as a pseudo solid with an arbitrary Lagrangian-Eulerian formulation and by repeatedly performing re-meshing with CUBIT and re-mapping with MAPVAR, the moving deposition surfaces were tracked explicitly from start of deposition until the trenches were filled with metal, thus enabling the computation of local current densities that potentially influence the microstructure and frictional/mechanical properties of the deposit. The multi-dimensional, multi-species, transient computational framework was demonstrated in case studies of two-dimensional nickel electrodeposition in single and multiple trenches, without and with bath stirring or forced flow. Effects of buoyancy-induced convection on deposition were also investigated. To further illustrate its utility, the framework was employed to simulate deposition in microscreen-based LIGA molds. Lastly, future needs for modeling LIGA electrodeposition are discussed.« less
Water Impact Test and Simulation of a Composite Energy Absorbing Fuselage Section
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Jackson, Karen E.; Sparks, Chad; Sareen, Ashish
2003-01-01
In March 2002, a 25-ft/s vertical drop test of a composite fuselage section was conducted onto water. The purpose of the test was to obtain experimental data characterizing the structural response of the fuselage section during water impact for comparison with two previous drop tests that were performed onto a rigid surface and soft soil. For the drop test, the fuselage section was configured with ten 100-lb. lead masses, five per side, that were attached to seat rails mounted to the floor. The fuselage section was raised to a height of 10-ft. and dropped vertically into a 15-ft. diameter pool filled to a depth of 3.5-ft. with water. Approximately 70 channels of data were collected during the drop test at a 10-kHz sampling rate. The test data were used to validate crash simulations of the water impact that were developed using the nonlinear, explicit transient dynamic codes, MSC.Dytran and LS-DYNA. The fuselage structure was modeled using shell and solid elements with a Lagrangian mesh, and the water was modeled with both Eulerian and Lagrangian techniques. The fluid-structure interactions were executed using the fast general coupling in MSC.Dytran and the Arbitrary Lagrange-Euler (ALE) coupling in LS-DYNA. Additionally, the smooth particle hydrodynamics (SPH) meshless Lagrangian technique was used in LS-DYNA to represent the fluid. The simulation results were correlated with the test data to validate the modeling approach. Additional simulation studies were performed to determine how changes in mesh density, mesh uniformity, fluid viscosity, and failure strain influence the test-analysis correlation.
Airflow attenuation and bed net utilization: observations from Africa and Asia.
von Seidlein, Lorenz; Ikonomidis, Konstantin; Bruun, Rasmus; Jawara, Musa; Pinder, Margaret; Knols, Bart Gj; Knudsen, Jakob B
2012-06-15
Qualitative studies suggest that bed nets affect the thermal comfort of users. To understand and reduce this discomfort the effect of bed nets on temperature, humidity, and airflow was measured in rural homes in Asia and Africa, as well as in an experimental wind tunnel. Two investigators with architectural training selected 60 houses in The Gambia, Tanzania, Philippines, and Thailand. Data-loggers were used to measure indoor temperatures in hourly intervals over a 12 months period. In a subgroup of 20 houses airflow, temperature and humidity were measured at five-minute intervals for one night from 21.00 to 6.00 hrs inside and outside of bed nets using sensors and omni-directional thermo-anemometers. An investigator set up a bed net with a mesh size of 220 holes per inch 2 in each study household and slept under the bed net to simulate a realistic environment. The attenuation of airflow caused by bed nets of different mesh sizes was also measured in an experimental wind tunnel. The highest indoor temperatures (49.0 C) were measured in The Gambia. During the hottest months of the year the mean temperature at night (9 pm) was between 33.1 C (The Gambia) and 26.2 C (Thailand). The bed net attenuated the airflow from a minimum of 27% (Philippines) to a maximum of 71% (The Gambia). Overall the bed nets reduced airflow compared to un-attenuated airflow from 9 to 4 cm sec-1 or 52% (p<0.001). In all sites, no statistically significant difference in temperature or humidity was detected between the inside and outside of the bed net. Wind tunnel experiments with 11 different mesh-sized bed nets showed an overall reduction in airflow of 64% (range 55 - 71%) compared to un-attenuated airflow. As expected, airflow decreased with increasing net mesh size. Nets with a mesh of 136 holes inch-2 reduced airflow by 55% (mean; range 51 - 73%). A denser net (200 holes inch-2) attenuated airflow by 59% (mean; range 56 - 74%). Despite concerted efforts to increase the uptake of this intervention in many areas uptake remains poor. Bed nets reduce airflow, but have no influence on temperature and humidity. The discomfort associated with bed nets is likely to be most intolerable during the hottest and most humid period of the year, which frequently coincides with the peak of malaria vector densities and the force of pathogen transmission. These observations suggest thermal discomfort is a factor limiting bed net use and open a range of architectural possibilities to overcome this limitation.
Influence of water on the surface of graphene
NASA Astrophysics Data System (ADS)
Kaya, Yunus; Kalkan, Yalçin; Veenhof, Rob
2018-02-01
We have studied how water modifies the surface of graphene and in particular how the surface conductivity of graphene is affected. According to the literature, two types of interactions should be distinguished: physical, where a water molecule remains intact and is located at some distance from the mesh, and chemical, where a water molecule is imbricated in the graphene bond structure. We have developed theoretical models for both types of interactions using the density functional theory (DFT) with the B3LYP hybrid functional combined with the 6-31G(d) basis set. Our calculations show that the surface conductivity of graphene is reduced in the presence of water.
NASA Technical Reports Server (NTRS)
Nouri, Nima; Panerai, Francesco; Tagavi, Kaveh A.; Mansour, Nagi N.; Martin, Alexandre
2015-01-01
The radiative heat transfer inside a low-density carbon fiber insulator is analyzed using a three-dimensional direct simulation model. A robust procedure is presented for the numerical calculation of the geometric configuration factor to compute the radiative energy exchange processes among the small discretized surface areas of the fibrous material. The methodology is applied to a polygonal mesh of a fibrous insulator obtained from three-dimensional microscale imaging of the real material. The anisotropic values of the radiative conductivity are calculated for that geometry. The results yield both directional and thermal dependence of the radiative conductivity.
Utilization of flax fibers for biomedical applications.
Michel, Sophie A A X; Vogels, Ruben R M; Bouvy, Nicole D; Knetsch, Menno L W; van den Akker, Nynke M S; Gijbels, Marion J J; van der Marel, Cees; Vermeersch, Jan; Molin, Daniel G M; Koole, Leo H
2014-04-01
Over the past decades, a large number of animal-derived materials have been introduced for several biomedical applications. Surprisingly, the use of plant-based materials has lagged behind. To study the feasibility of plant-derived biomedical materials, we chose flax (Linum usitatissimum). Flax fibers possess excellent physical-mechanical properties, are nonbiodegradable, and there is extensive know-how on weaving/knitting of them. One area where they could be useful is as implantable mesh structures in surgery, in particular for the repair of incisional hernias of the abdominal wall. Starting with a bleached flax thread, a prototype mesh was specifically knitted for this study, and its cytocompatibility was studied in vitro and in vivo. The experimental data revealed that application of flax in surgery first requires a robust method to remove endotoxins and purify the flax fiber. Such a method was developed, and purified meshes did not cause loss of cell viability in vitro. In addition, endotoxins determined using limulus amebocyte lysate test were at acceptable levels. In vivo, the flax meshes showed only mild inflammation, comparable to commercial polypropylene meshes. This study revealed that plant-derived biomaterials can provide a new class of implantable materials that could be used as surgical meshes or for other biomedical applications. Copyright © 2013 Wiley Periodicals, Inc.
Mesh size effects on assessments of planktonic hydrozoan abundance and assemblage structure
NASA Astrophysics Data System (ADS)
Nogueira Júnior, Miodeli; Pukanski, Luis Eduardo de M.; Souza-Conceição, José M.
2015-04-01
The choice of appropriate mesh-size is paramount to accurately quantify planktonic assemblages, however there is no such information available for hydrozoans. Here planktonic hydrozoan abundance and assemblage structure were compared using 200 and 500 μm meshes at Babitonga estuary (S Brazil), throughout a year cycle. Species richness and Shannon-Wiener diversity were higher in the 200 μm mesh, while evenness was typically higher in the 500 μm. Assemblage structure was significantly different between meshes (PERMANOVA, P < 0.05; n = 72 pairs of samples) both regarding taxa and size composition. These discrepancies are due to significant underestimation of small hydromedusae by the coarse mesh, like Obelia spp., young Liriope tetraphylla, Podocoryna loyola and others. Yet, larger taxa like Eucheilota maculata and adult L. tetraphylla were more abundant in the coarse mesh on some occasions and others such as Blackfordia virginica and Muggiaea kochi were similarly represented in both meshes. Overall collection efficiency of the coarse mesh (CE500) was 14.4%, with monthly averages between 1.6% and 43.0%, in July (winter) and January (summer) respectively. Differences between the meshes were size-dependent; CE500 was ~ 0.3% for hydrozoans sizing < 0.5 mm, ~ 21% for those between 1 and 2 mm, ~ 56% for those between 2 and 4 mm, and nearly 100% for larger ones, reaching up to 312% for hydrozoans > 8 mm in October. These results suggest that both meshes have their drawbacks and the best choice would depend on the objectives of each study. Nevertheless species richness, total abundances and most taxa were better represented by the 200 μm mesh, suggesting that it is more appropriate to quantitatively sample planktonic hydrozoan assemblages.
Okamoto, Eiji; Kikuchi, Sakiko; Mitamura, Yoshinori
2016-09-01
We have developed a tissue-inducing electrode using titanium mesh to obtain mechanically and electrically stable contact with the tissue for a new transcutaneous communication system using the human body as a conductive medium. In this study, we investigated the electrical properties of the titanium mesh electrode by measuring electrode-tissue interface resistance in vivo. The titanium mesh electrode (Hi-Lex Co., Zellez, Hyogo, Japan) consisted of titanium fibers (diameter of 50 μm), and it has an average pore size of 200 μm and 87 % porosity. The titanium mesh electrode has a diameter of 5 mm and thickness of 1.5 mm. Three titanium mesh electrodes were implanted separately into the dorsal region of the rat. We measured the electrode-electrode impedance using an LCR meter for 12 weeks, and we calculated the tissue resistivity and electrode-tissue interface resistance. The electrode-tissue interface resistance of the titanium mesh electrode decreased slightly until the third POD and then continuously increased to 75 Ω. The electrode-tissue interface resistance of the titanium mesh electrode is stable and it has lower electrode-tissue interface resistance than that of a titanium disk electrode. The extracted titanium mesh electrode after 12 weeks implantation was fixed in 10 % buffered formalin solution and stained with hematoxylin-eosin. Light microscopic observation showed that the titanium mesh electrode was filled with connective tissue, inflammatory cells and fibroblasts with some capillaries in the pores of the titanium mesh. The results indicate that the titanium mesh electrode is a promising electrode for the new transcutaneous communication system.
Effects of mesh-related complications in vaginal surgery on quality of life.
Kowalik, Claudia R; Lakeman, Mariëlle M E; de Kraker, Alyde T; Roovers, Jan Paul W R
2018-06-16
Vaginal mesh surgery is subject of debate due to the impact of mesh-related complications on patient's lives. Not all of these complications are symptomatic. Restoration of the anatomy and improvement of pelvic floor function as a result may counter the experienced discomfort related to adverse events. We hypothesized that health-related quality of life (HR-QoL) is comparable in women after vaginal mesh surgery regardless of the presence or absence of a mesh-specific complication. This was a cross-sectional study of 128 women who had vaginal mesh surgery in a Dutch university hospital between 2007 and 2012. HR-QoL was measured in women with and without mesh complications using standardized QoL questionnaires Urogenital Distress Inventory-6 (UDI-6), Incontinence Impact Questionnaire (IIQ), Defecation Distress Inventory (DDI), and Pelvic Organ Prolapse/Urinary Incontinence Sexual Function Questionnaire (PISQ-12). Complications were scored according to the International Urogynecological Association (IUGA) complication classification. Comparisons between groups were performed with Student's t test and analysis of variance (ANOVA) test. In 29 (23%) women, a mesh-related complication occurred. The domain scores of the UDI-6, DDI, IIQ, and PISQ showed no statistically significant differences between women with and without a mesh-related complication. A post hoc analysis showed similar HR-QoL for those in whom the complication had been resolved and those with persistent symptoms of the complication. Mesh surgery imposes specific complications. When counseling patients about the potential adverse events related to vaginal mesh surgery, it is important to inform them that mesh-related complications do not negatively affect QoL related to micturition, defecation, and sexual functioning.
Pitfalls in retromuscular mesh repair for incisional hernia: the importance of the "fatty triangle".
Conze, J; Prescher, A; Klinge, U; Saklak, M; Schumpelick, V
2004-08-01
Open retromuscular mesh repair has become a standard procedure in incisional hernia repair. This technique led to a significant decrease of recurrences. Recurrences after this technique typically occur at the upper mesh border and are a result of the technical complexity of reaching the postulated underlay of 5 cm in the region of the linea alba. We performed an anatomical study in human corpses to investigate the abdominal wall with its different structures, with emphasis on the overlap of the mesh under the linea alba. The overlap can be achieved by incision of the posterior lamina of the rectus sheath, on both sides close to the linea alba. The incision opens the preperitoneal space and appears in the shape of a "fatty triangle". The anterior lamina of the rectus sheath above the hernia defect remains intact and facilitates a sufficient thrust bearing for a retromuscular mesh implantation. Knowledge of the anatomy and preparation of the "fatty triangle" enables a mesh positioning according to the principles of retromuscular mesh repair.
Stress adapted embroidered meshes with a graded pattern design for abdominal wall hernia repair
NASA Astrophysics Data System (ADS)
Hahn, J.; Bittrich, L.; Breier, A.; Spickenheuer, A.
2017-10-01
Abdominal wall hernias are one of the most relevant injuries of the digestive system with 25 million patients in 2013. Surgery is recommended primarily using allogenic non-absorbable wrap-knitted meshes. These meshes have in common that their stress-strain behaviour is not adapted to the anisotropic behaviour of native abdominal wall tissue. The ideal mesh should possess an adequate mechanical behaviour and a suitable porosity at the same time. An alternative fabrication method to wrap-knitting is the embroidery technology with a high flexibility in pattern design and adaption of mechanical properties. In this study, a pattern generator was created for pattern designs consisting of a base and a reinforcement pattern. The embroidered mesh structures demonstrated different structural and mechanical characteristics. Additionally, the investigation of the mechanical properties exhibited an anisotropic mechanical behaviour for the embroidered meshes. As a result, the investigated pattern generator and the embroidery technology allow the production of stress adapted mesh structures that are a promising approach for hernia reconstruction.
LayTracks3D: A new approach for meshing general solids using medial axis transform
Quadros, William Roshan
2015-08-22
This study presents an extension of the all-quad meshing algorithm called LayTracks to generate high quality hex-dominant meshes of general solids. LayTracks3D uses the mapping between the Medial Axis (MA) and the boundary of the 3D domain to decompose complex 3D domains into simpler domains called Tracks. Tracks in 3D have no branches and are symmetric, non-intersecting, orthogonal to the boundary, and the shortest path from the MA to the boundary. These properties of tracks result in desired meshes with near cube shape elements at the boundary, structured mesh along the boundary normal with any irregular nodes restricted to themore » MA, and sharp boundary feature preservation. The algorithm has been tested on a few industrial CAD models and hex-dominant meshes are shown in the Results section. Work is underway to extend LayTracks3D to generate all-hex meshes.« less
Evaluation on Bending Properties of Biomaterial GUM Metal Meshed Plates for Bone Graft Applications
NASA Astrophysics Data System (ADS)
Suzuki, Hiromichi; He, Jianmei
2017-11-01
There are three bone graft methods for bone defects caused by diseases such as cancer and accident injuries: Autogenous bone grafts, Allografts and Artificial bone grafts. In this study, meshed GUM Metal plates with lower elasticity, high strength and high biocompatibility are introduced to solve the over stiffness & weight problems of ready-used metal implants. Basic mesh shapes are designed and applied to GUM Metal plates using 3D CAD modeling tools. Bending properties of prototype meshed GUM Metal plates are evaluated experimentally and analytically. Meshed plate specimens with 180°, 120° and 60° axis-symmetrical types were fabricated for 3-point bending tests. The pseudo bending elastic moduli of meshed plate specimens obtained from 3-point bending test are ranged from 4.22 GPa to 16.07 GPa, within the elasticity range of natural cortical bones from 2.0 GPa to 30.0 GPa. Analytical approach method is validated by comparison with experimental and analytical results for evaluation on bending property of meshed plates.
Safety of Synthetic Glue Used for Laparoscopic Prolapse Treatment.
Sarasa Castelló, Núria; Toth, Alexandra; Canis, Michel; Botchorishvilli, Revaz
2017-12-29
We detected mesh erosion and serious postoperative complications in 3 women after performing laparoscopic promontofixation (LPF) using glue for mesh fixation. Glue, largely used in hernia surgery repair, is proposed by some gynecologic surgeons because it saves time and is easier to use than traditional sutures. We report 3 cases of postoperative complications after LPF in which glue had been used and provide research in the published literature about the use of glue in LPF. A research of glue use in gynecology mesh fixation was performed through PubMed on October 2016. The search was done using the Medical Subject Heading terms "POP" & "Laparoscopy" & "surgical Mesh" and the word either "glue" or "adhesive. Only 2 articles were found: Willecocq et al [1] and Estrade et al [2]. Neither study focused on postoperative complications. In this publication, we accurately edited video surgeries with an instructive purpose. University Hospital of Clermont-Ferrand, France. Patient A, a 65-year-old woman, complained of pelvic pain and vaginal discharge 1 month after LPF (polypropylene mesh and glue had been used). Wall mesh exposure and purulent discharge were noted. She received antibiotics and underwent mesh ablation surgery; debris of the glue was easily identified. Patient B, a 65-year-old lady with previous hysterectomy consulted for a bulging feeling in her vagina (classification: cystocele +2; rectocele +3 stage). An LPF was performed using polypropylene soft nonabsorbable mesh and glue. One month later, an apical defect of vaginal epithelialization was detected; she received long estrogenic local treatment but had to undergo surgery when presenting malodorous discharge and mesh exposure. The exposed mesh was removed, and pieces of glue were identified, having avoided mesh attachment. Patient C had a previous abdominal hysterectomy and promontofixation using a polyester mesh with glue. She consulted to us for vaginal mesh erosion covered with purulent discharge 3.5 years after LPF in another center. At the surgery, 1 cm of the prosthesis was identified in the vagina, dissected, and sutured. One year later, she consulted for dyspareunia and purulent discharge; vaginal rigid mesh exposure with an epithelization defect and inflammatory signs was seen. During laparoscopy, prosthetic exposition and glue debris on the prosthesis were identified. In all 3 cases, debris of glue were identified in the no integrated mesh area. The suggested reasons of exposure can be the excessive amount of surgical glue applied. Moreover, a large amount of glue may be impairing tissue ingrowth through the mesh pores, causing low fibrosis and poor tissue integration [3]. Glue seems to prevent fibrosis from occurring. Its use in pelvic organ prolapse laparoscopic mesh fixation should be done with caution. No prospective studies reporting long-term comorbidities and results have been published. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.
Gault, Lora V.; Shultz, Mary; Davies, Kathy J.
2002-01-01
Objectives: This study compared the mapping of natural language patron terms to the Medical Subject Headings (MeSH) across six MeSH interfaces for the MEDLINE database. Methods: Test data were obtained from search requests submitted by patrons to the Library of the Health Sciences, University of Illinois at Chicago, over a nine-month period. Search request statements were parsed into separate terms or phrases. Using print sources from the National Library of Medicine, Each parsed patron term was assigned corresponding MeSH terms. Each patron term was entered into each of the selected interfaces to determine how effectively they mapped to MeSH. Data were collected for mapping success, accessibility of MeSH term within mapped list, and total number of MeSH choices within each list. Results: The selected MEDLINE interfaces do not map the same patron term in the same way, nor do they consistently lead to what is considered the appropriate MeSH term. Conclusions: If searchers utilize the MEDLINE database to its fullest potential by mapping to MeSH, the results of the mapping will vary between interfaces. This variance may ultimately impact the search results. These differences should be considered when choosing a MEDLINE interface and when instructing end users. PMID:11999175
Gault, Lora V; Shultz, Mary; Davies, Kathy J
2002-04-01
This study compared the mapping of natural language patron terms to the Medical Subject Headings (MeSH) across six MeSH interfaces for the MEDLINE database. Test data were obtained from search requests submitted by patrons to the Library of the Health Sciences, University of Illinois at Chicago, over a nine-month period. Search request statements were parsed into separate terms or phrases. Using print sources from the National Library of Medicine, Each parsed patron term was assigned corresponding MeSH terms. Each patron term was entered into each of the selected interfaces to determine how effectively they mapped to MeSH. Data were collected for mapping success, accessibility of MeSH term within mapped list, and total number of MeSH choices within each list. The selected MEDLINE interfaces do not map the same patron term in the same way, nor do they consistently lead to what is considered the appropriate MeSH term. If searchers utilize the MEDLINE database to its fullest potential by mapping to MeSH, the results of the mapping will vary between interfaces. This variance may ultimately impact the search results. These differences should be considered when choosing a MEDLINE interface and when instructing end users.
NASA Astrophysics Data System (ADS)
Sanbhal, Noor; Mao, Ying; Sun, Gang; Xu, Rui Fang; Zhang, Qian; Wang, Lu
2018-05-01
Light weight polypropylene (PP) mesh is the most widely used implant among all other synthetic meshes for hernia repair. However, infection is the complication associated to all synthetic meshes after hernia repair. Thus, to manage mesh related infection; antibacterial drug is generally loaded to surgical implants to supply drug locally in mesh implanted site. Nevertheless, PP mesh restricts the loading of antibacterial drug at operated area due to its low wettability. The aim of this study was to introduce a novel antimicrobial PP mesh modified with β-cyclodextrine (CD) and loaded with antimicrobial agent for infection prevention. A cold oxygen plasma treatment was able to activate the surfaces of polypropylene fibers, and then CD was incorporated onto the surfaces of PP fibers. Afterward, triclosan, as a model antibacterial agent, was loaded into CD cavity to provide desired antibacterial functions. The modified polypropylene mesh samples CD-Tric-1, CD-Tric-3 exhibited excellent inhibition zone and continuous antibacterial efficacy against E. coli and S. aureus up to 6 and 7 days respectively. Results of AFM, SEM, FTIR and antibacterial tests evidenced that oxygen plasma process is necessary to increase chemical connection between CD molecules and PP fibers. The samples were also characterized by using EDX, XRD, TGA, DSC and water contact angle.
An exact general remeshing scheme applied to physically conservative voxelization
Powell, Devon; Abel, Tom
2015-05-21
We present an exact general remeshing scheme to compute analytic integrals of polynomial functions over the intersections between convex polyhedral cells of old and new meshes. In physics applications this allows one to ensure global mass, momentum, and energy conservation while applying higher-order polynomial interpolation. We elaborate on applications of our algorithm arising in the analysis of cosmological N-body data, computer graphics, and continuum mechanics problems. We focus on the particular case of remeshing tetrahedral cells onto a Cartesian grid such that the volume integral of the polynomial density function given on the input mesh is guaranteed to equal themore » corresponding integral over the output mesh. We refer to this as “physically conservative voxelization.” At the core of our method is an algorithm for intersecting two convex polyhedra by successively clipping one against the faces of the other. This algorithm is an implementation of the ideas presented abstractly by Sugihara [48], who suggests using the planar graph representations of convex polyhedra to ensure topological consistency of the output. This makes our implementation robust to geometric degeneracy in the input. We employ a simplicial decomposition to calculate moment integrals up to quadratic order over the resulting intersection domain. We also address practical issues arising in a software implementation, including numerical stability in geometric calculations, management of cancellation errors, and extension to two dimensions. In a comparison to recent work, we show substantial performance gains. We provide a C implementation intended to be a fast, accurate, and robust tool for geometric calculations on polyhedral mesh elements.« less
Loft: An Automated Mesh Generator for Stiffened Shell Aerospace Vehicles
NASA Technical Reports Server (NTRS)
Eldred, Lloyd B.
2011-01-01
Loft is an automated mesh generation code that is designed for aerospace vehicle structures. From user input, Loft generates meshes for wings, noses, tanks, fuselage sections, thrust structures, and so on. As a mesh is generated, each element is assigned properties to mark the part of the vehicle with which it is associated. This property assignment is an extremely powerful feature that enables detailed analysis tasks, such as load application and structural sizing. This report is presented in two parts. The first part is an overview of the code and its applications. The modeling approach that was used to create the finite element meshes is described. Several applications of the code are demonstrated, including a Next Generation Launch Technology (NGLT) wing-sizing study, a lunar lander stage study, a launch vehicle shroud shape study, and a two-stage-to-orbit (TSTO) orbiter. Part two of the report is the program user manual. The manual includes in-depth tutorials and a complete command reference.
A critical review of biologic mesh use in ventral hernia repairs under contaminated conditions.
Primus, F E; Harris, H W
2013-02-01
We used an evidence-based approach to determine whether the promotions and claims of superiority of biologic mesh over synthetic mesh use in ventral hernia repairs (VHRs) under contaminated conditions were sound and valid. We searched the Medline database to specifically identify review articles relating to biologic mesh and VHR and critically reviewed these studies using an evidence-based approach. For the past 45 years, four clinical reviews and one systematic review have included biologic meshes as part of a larger discussion on available prosthetics for VHR. All reviews supported biologic mesh use, especially in the setting of contaminated fields. Yet, the primary literature included in these reviews and served as the basis for these conclusions consisted entirely of case series and case reports, which have the lowest level of evidence in determining scientific validity. Furthermore, the FDA has neither cleared nor approved this particular use. The cumulative data regarding biologic mesh use in VHRs under contaminated conditions does not support the claim that it is better than synthetic mesh used under the same conditions. The highly promoted and at least moderately utilized practice of placing biologic mesh in contamination is being done outside of the original intended use, and a re-evaluation of or possible moratorium on biologic mesh use in hernia surgery is seriously warranted. Alternatively, an industry-sponsored national registry of patients in whom ventral hernia repairs involved biologic mesh would substantively add to our understanding regarding how these intriguing biomaterials are being used and their overall clinical efficacy.
Transabdominal preperitoneal herniorrhaphy using laser-assisted tissue soldering in a porcine model.
Lanzafame, Raymond J; Soltz, Barbara A; Stadler, Istvan; Soltz, Robert
2009-01-01
Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45micro, 4.5W CW, 5mm spot, and 55 degrees C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted.
NASA Technical Reports Server (NTRS)
Ricks, Trenton M.; Lacy, Thomas E., Jr.; Pineda, Evan J.; Bednarcyk, Brett A.; Arnold, Steven M.
2013-01-01
A multiscale modeling methodology, which incorporates a statistical distribution of fiber strengths into coupled micromechanics/ finite element analyses, is applied to unidirectional polymer matrix composites (PMCs) to analyze the effect of mesh discretization both at the micro- and macroscales on the predicted ultimate tensile (UTS) strength and failure behavior. The NASA code FEAMAC and the ABAQUS finite element solver were used to analyze the progressive failure of a PMC tensile specimen that initiates at the repeating unit cell (RUC) level. Three different finite element mesh densities were employed and each coupled with an appropriate RUC. Multiple simulations were performed in order to assess the effect of a statistical distribution of fiber strengths on the bulk composite failure and predicted strength. The coupled effects of both the micro- and macroscale discretizations were found to have a noticeable effect on the predicted UTS and computational efficiency of the simulations.
NASA Astrophysics Data System (ADS)
Lee, Hyunjae; Choi, Tae Kyu; Lee, Young Bum; Cho, Hye Rim; Ghaffari, Roozbeh; Wang, Liu; Choi, Hyung Jin; Chung, Taek Dong; Lu, Nanshu; Hyeon, Taeghwan; Choi, Seung Hong; Kim, Dae-Hyeong
2016-06-01
Owing to its high carrier mobility, conductivity, flexibility and optical transparency, graphene is a versatile material in micro- and macroelectronics. However, the low density of electrochemically active defects in graphene synthesized by chemical vapour deposition limits its application in biosensing. Here, we show that graphene doped with gold and combined with a gold mesh has improved electrochemical activity over bare graphene, sufficient to form a wearable patch for sweat-based diabetes monitoring and feedback therapy. The stretchable device features a serpentine bilayer of gold mesh and gold-doped graphene that forms an efficient electrochemical interface for the stable transfer of electrical signals. The patch consists of a heater, temperature, humidity, glucose and pH sensors and polymeric microneedles that can be thermally activated to deliver drugs transcutaneously. We show that the patch can be thermally actuated to deliver Metformin and reduce blood glucose levels in diabetic mice.
N-body simulations for f(R) gravity using a self-adaptive particle-mesh code
NASA Astrophysics Data System (ADS)
Zhao, Gong-Bo; Li, Baojiu; Koyama, Kazuya
2011-02-01
We perform high-resolution N-body simulations for f(R) gravity based on a self-adaptive particle-mesh code MLAPM. The chameleon mechanism that recovers general relativity on small scales is fully taken into account by self-consistently solving the nonlinear equation for the scalar field. We independently confirm the previous simulation results, including the matter power spectrum, halo mass function, and density profiles, obtained by Oyaizu [Phys. Rev. DPRVDAQ1550-7998 78, 123524 (2008)10.1103/PhysRevD.78.123524] and Schmidt [Phys. Rev. DPRVDAQ1550-7998 79, 083518 (2009)10.1103/PhysRevD.79.083518], and extend the resolution up to k˜20h/Mpc for the measurement of the matter power spectrum. Based on our simulation results, we discuss how the chameleon mechanism affects the clustering of dark matter and halos on full nonlinear scales.
Periurban Trypanosoma cruzi–infected Triatoma infestans, Arequipa, Peru
Bowman, Natalie M.; Kawai, Vivian; Waller, Lance A.; Cornejo del Carpio, Juan Geny; Benzaquen, Eleazar Cordova; Gilman, Robert H.; Bern, Caryn
2006-01-01
In Arequipa, Peru, vectorborne transmission of Chagas disease by Triatoma infestans has become an urban problem. We conducted an entomologic survey in a periurban community of Arequipa to identify risk factors for triatomine infestation and determinants of vector population densities. Of 374 households surveyed, triatomines were collected from 194 (52%), and Trypanosoma cruzi–carrying triatomines were collected from 72 (19.3%). Guinea pig pens were more likely than other animal enclosures to be infested and harbored 2.38× as many triatomines. Stacked brick and adobe enclosures were more likely to have triatomines, while wire mesh enclosures were protected against infestation. In human dwellings, only fully stuccoed rooms were protected against infestation. Spatially, households with triatomines were scattered, while households with T. cruzi–infected triatomines were clustered. Keeping small animals in wire mesh cages could facilitate control of T. infestans in this densely populated urban environment. PMID:17073082
Inflow/Outflow Boundary Conditions with Application to FUN3D
NASA Technical Reports Server (NTRS)
Carlson, Jan-Renee
2011-01-01
Several boundary conditions that allow subsonic and supersonic flow into and out of the computational domain are discussed. These boundary conditions are demonstrated in the FUN3D computational fluid dynamics (CFD) code which solves the three-dimensional Navier-Stokes equations on unstructured computational meshes. The boundary conditions are enforced through determination of the flux contribution at the boundary to the solution residual. The boundary conditions are implemented in an implicit form where the Jacobian contribution of the boundary condition is included and is exact. All of the flows are governed by the calorically perfect gas thermodynamic equations. Three problems are used to assess these boundary conditions. Solution residual convergence to machine zero precision occurred for all cases. The converged solution boundary state is compared with the requested boundary state for several levels of mesh densities. The boundary values converged to the requested boundary condition with approximately second-order accuracy for all of the cases.
Microstructure-Based Computational Modeling of Mechanical Behavior of Polymer Micro/Nano Composites
2013-12-01
K. ......... 165 Fig. 5.11. Comparison between experimental data and calibrated numerical models for displacement control tests, at three different...displacement control simulation) for all mesh densities for both work-conjugate and non work-conjugate. ........................ 302 Fig. 9.3. Damage...some large deformation experimental tests (and also accepting the non -uniformity of the strain field). In the established well-known theorem for
Cheng, Yuanyuan; Wu, Bei; Ma, Xiaofan; Lu, Shixiang; Xu, Wenguo; Szunerits, Sabine; Boukherroub, Rabah
2018-04-18
Inspired by the lotus effect and water-repellent properties of water striders' legs, superhydrophobic surfaces have been intensively investigated from both fundamental and applied perspectives for daily and industrial applications. Various techniques are available for the fabrication of artificial superoleophilic/superhydrophobic (SS). However, most of these techniques are tedious and often require hazardous or expensive equipment, which hampers their implementation for practical applications. In the present work, we used a versatile and straightforward technique based on polymer drop-casting for the preparation SS materials that can be implemented on any substrate. High density polyethylene (HDPE) SS coatings were prepared on different substrates (glass, copper mesh and polyurethane (PU) sponge) by drop casting the parent polymer xylene-ethanol solution at room temperature. All the substrates exhibited a superhydrophobic behavior with a water contact angle (WCA) greater than 150°. Furthermore, the corrosion resistance, stability, self-cleaning property, and water/oil separation of the developed materials were also assessed. While copper mesh and PU sponge exhibited good ability for oil and organic solvents separation from water, the HDPE-functionalized PU sponge displayed good adsorption capacity, 32-90 times the weight of adsorbed substance vs. the weight of adsorbent. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Vazquez, Gerardo; Magana, Fernando; Salas-Torres, Osiris
We explore the structural interactions between graphene and transition metals such as palladium (Pd) and titanium (Ti) and the possibility of inducing superconductivity in a graphene sheet in two cases, one by doping its surface with palladium atoms sit on the center of the hexagons of the graphene layer and other by covering the graphene layer with two layers of titanium metal atoms. The results here were obtained from first-principles density functional theory in the local density approximation. The Quantum-Espresso package was used with norm conserving pseudopotentials. All of the structures considered were relaxed to their minimum energy configuration. Phonon frequencies were calculated using the linear-response technique on several phonon wave-vector mesh. The electron-phonon coupling parameter was calculated with several electron momentum k-mesh. The superconducting critical temperature was estimated using the Allen-Dynes formula with μ* = 0.1 - 0.15. We note that palladium and titanium are good candidate materials to show a metal-to-superconductor transition. We thank Dirección General de Asuntos del Personal Académico de la Universidad Nacional Autónoma de México, partial financial support by Grant IN-106514 and we also thank Miztli Super-Computing center the technical assistance.
Design of an essentially non-oscillatory reconstruction procedure on finite-element type meshes
NASA Technical Reports Server (NTRS)
Abgrall, R.
1991-01-01
An essentially non-oscillatory reconstruction for functions defined on finite-element type meshes was designed. Two related problems are studied: the interpolation of possibly unsmooth multivariate functions on arbitrary meshes and the reconstruction of a function from its average in the control volumes surrounding the nodes of the mesh. Concerning the first problem, we have studied the behavior of the highest coefficients of the Lagrange interpolation function which may admit discontinuities of locally regular curves. This enables us to choose the best stencil for the interpolation. The choice of the smallest possible number of stencils is addressed. Concerning the reconstruction problem, because of the very nature of the mesh, the only method that may work is the so called reconstruction via deconvolution method. Unfortunately, it is well suited only for regular meshes as we show, but we also show how to overcome this difficulty. The global method has the expected order of accuracy but is conservative up to a high order quadrature formula only. Some numerical examples are given which demonstrate the efficiency of the method.
Monte Carlo simulation and film dosimetry for electron therapy in vicinity of a titanium mesh
Rostampour, Masoumeh; Roayaei, Mahnaz
2014-01-01
Titanium (Ti) mesh plates are used as a bone replacement in brain tumor surgeries. In the case of radiotherapy, these plates might interfere with the beam path. The purpose of this study is to evaluate the effect of titanium mesh on the dose distribution of electron fields. Simulations were performed using Monte Carlo BEAMnrc and DOSXYZnrc codes for 6 and 10 MeV electron beams. In Monte Carlo simulation, the shape of the titanium mesh was simulated. The simulated titanium mesh was considered as the one which is used in head and neck surgery with a thickness of 0.055 cm. First, by simulation, the percentage depth dose was obtained while the titanium mesh was present, and these values were then compared with the depth dose of homogeneous phantom with no titanium mesh. In the experimental measurements, the values of depth dose with titanium mesh and without titanium mesh in various depths were measured. The experiments were performed using a RW3 phantom with GAFCHROMIC EBT2 film. The results of experimental measurements were compared with values of depth dose obtained by simulation. In Monte Carlo simulation, as well as experimental measurements, for the voxels immediately beyond the titanium mesh, the change of the dose were evaluated. For this purpose the ratio of the dose for the case with titanium to the case without titanium was calculated as a function of titanium depth. For the voxels before the titanium mesh there was always an increase of the dose up to 13% with respect to the same voxel with no titanium mesh. This is because of the increased back scattering effect of the titanium mesh. The results also showed that for the voxel right beyond the titanium mesh, there is an increased or decreased dose to soft tissues, depending on the depth of the titanium mesh. For the regions before the depth of maximum dose, there is an increase of the dose up to 10% compared to the dose of the same depth in homogeneous phantom. Beyond the depth of maximum dose, there was a 16% decrease in dose. For both 6 and 10 MeV, before the titanium mesh, there was always an increase in dose. If titanium mesh is placed in buildup region, it causes an increase of the dose and could lead to overdose of the adjacent tissue, whereas if titanium mesh is placed beyond the buildup region, it would lead to a decrease in dose compared to the homogenous tissue. PACS number: 87.53.Bn PMID:25207397
NASA Astrophysics Data System (ADS)
Yao, Yuan; Capecelatro, Jesse
2018-03-01
We present a numerical study on inertial electrically charged particles suspended in a turbulent carrier phase. Fluid-particle interactions are accounted for in an Eulerian-Lagrangian (EL) framework and coupled to a Fourier-based Ewald summation method, referred to as the particle-particle-particle-mesh (P3M ) method, to accurately capture short- and long-range electrostatic forces in a tractable manner. The EL P3M method is used to assess the competition between drag and Coulomb forces for a range of Stokes numbers and charge densities. Simulations of like- and oppositely charged particles suspended in a two-dimensional Taylor-Green vortex and three-dimensional homogeneous isotropic turbulence are reported. It is found that even in dilute suspensions, the short-range electric potential plays an important role in flows that admit preferential concentration. Suspensions of oppositely charged particles are observed to agglomerate in the form of chains and rings. Comparisons between the particle-mesh method typically employed in fluid-particle calculations and P3M are reported, in addition to one-point and two-point statistics to quantify the level of clustering as a function of Reynolds number, Stokes number, and nondimensional electric settling velocity.
Unified pipe network method for simulation of water flow in fractured porous rock
NASA Astrophysics Data System (ADS)
Ren, Feng; Ma, Guowei; Wang, Yang; Li, Tuo; Zhu, Hehua
2017-04-01
Rock masses are often conceptualized as dual-permeability media containing fractures or fracture networks with high permeability and porous matrix that is less permeable. In order to overcome the difficulties in simulating fluid flow in a highly discontinuous dual-permeability medium, an effective unified pipe network method is developed, which discretizes the dual-permeability rock mass into a virtual pipe network system. It includes fracture pipe networks and matrix pipe networks. They are constructed separately based on equivalent flow models in a representative area or volume by taking the advantage of the orthogonality of the mesh partition. Numerical examples of fluid flow in 2-D and 3-D domain including porous media and fractured porous media are presented to demonstrate the accuracy, robustness, and effectiveness of the proposed unified pipe network method. Results show that the developed method has good performance even with highly distorted mesh. Water recharge into the fractured rock mass with complex fracture network is studied. It has been found in this case that the effect of aperture change on the water recharge rate is more significant in the early stage compared to the fracture density change.
Large-Eddy Simulation of Subsonic Jets
NASA Astrophysics Data System (ADS)
Vuorinen, Ville; Wehrfritz, Armin; Yu, Jingzhou; Kaario, Ossi; Larmi, Martti; Boersma, Bendiks Jan
2011-12-01
The present study deals with development and validation of a fully explicit, compressible Runge-Kutta-4 (RK4) Navier-Stokes solver in the opensource CFD programming environment OpenFOAM. The background motivation is to shift towards explicit density based solution strategy and thereby avoid using the pressure based algorithms which are currently proposed in the standard OpenFOAM release for Large-Eddy Simulation (LES). This shift is considered necessary in strongly compressible flows when Ma > 0.5. Our application of interest is related to the pre-mixing stage in direct injection gas engines where high injection pressures are typically utilized. First, the developed flow solver is discussed and validated. Then, the implementation of subsonic inflow conditions using a forcing region in combination with a simplified nozzle geometry is discussed and validated. After this, LES of mixing in compressible, round jets at Ma = 0.3, 0.5 and 0.65 are carried out. Respectively, the Reynolds numbers of the jets correspond to Re = 6000, 10000 and 13000. Results for two meshes are presented. The results imply that the present solver produces turbulent structures, resolves a range of turbulent eddy frequencies and gives also mesh independent results within satisfactory limits for mean flow and turbulence statistics.
Jiang, Shuyong; Zhou, Tao; Tu, Jian; Shi, Laixin; Chen, Qiang; Yang, Mingbo
2017-01-01
Numerical modeling of microstructure evolution in various regions during uniaxial compression and canning compression of NiTi shape memory alloy (SMA) are studied through combined macroscopic and microscopic finite element simulation in order to investigate plastic deformation of NiTi SMA at 400 °C. In this approach, the macroscale material behavior is modeled with a relatively coarse finite element mesh, and then the corresponding deformation history in some selected regions in this mesh is extracted by the sub-model technique of finite element code ABAQUS and subsequently used as boundary conditions for the microscale simulation by means of crystal plasticity finite element method (CPFEM). Simulation results show that NiTi SMA exhibits an inhomogeneous plastic deformation at the microscale. Moreover, regions that suffered canning compression sustain more homogeneous plastic deformation by comparison with the corresponding regions subjected to uniaxial compression. The mitigation of inhomogeneous plastic deformation contributes to reducing the statistically stored dislocation (SSD) density in polycrystalline aggregation and also to reducing the difference of stress level in various regions of deformed NiTi SMA sample, and therefore sustaining large plastic deformation in the canning compression process. PMID:29027925
Hu, Li; Jiang, Shuyong; Zhou, Tao; Tu, Jian; Shi, Laixin; Chen, Qiang; Yang, Mingbo
2017-10-13
Numerical modeling of microstructure evolution in various regions during uniaxial compression and canning compression of NiTi shape memory alloy (SMA) are studied through combined macroscopic and microscopic finite element simulation in order to investigate plastic deformation of NiTi SMA at 400 °C. In this approach, the macroscale material behavior is modeled with a relatively coarse finite element mesh, and then the corresponding deformation history in some selected regions in this mesh is extracted by the sub-model technique of finite element code ABAQUS and subsequently used as boundary conditions for the microscale simulation by means of crystal plasticity finite element method (CPFEM). Simulation results show that NiTi SMA exhibits an inhomogeneous plastic deformation at the microscale. Moreover, regions that suffered canning compression sustain more homogeneous plastic deformation by comparison with the corresponding regions subjected to uniaxial compression. The mitigation of inhomogeneous plastic deformation contributes to reducing the statistically stored dislocation (SSD) density in polycrystalline aggregation and also to reducing the difference of stress level in various regions of deformed NiTi SMA sample, and therefore sustaining large plastic deformation in the canning compression process.
Baharestani, Mona Mylene; Gabriel, Allen
2011-04-01
The purpose of this study was to examine the clinical outcomes of negative pressure wound therapy (NPWT) using reticulated open-cell foam (ROCF) in the adjunctive management of abdominal wounds with exposed and known infected synthetic mesh. A non randomised, retrospective review of medical records for 21 consecutive patients with infected abdominal wounds treated with NPWT was conducted. All abdominal wounds contained exposed synthetic mesh [composite, polypropylene (PP), or knitted polyglactin 910 (PG) mesh]. Demographic and bacteriological data, wound history, pre-NPWT and comparative post-NPWT, operative procedures and complications, hospital length of stay (LOS) and wound healing outcomes were all analysed. Primary endpoints measured were (1) hospital LOS prior to initiation of NPWT, (2) total time on NPWT, (3) hospital LOS from NPWT initiation to discharge and (4) wound closure status at discharge. A total of 21 patients with abdominal wounds with exposed, infected mesh were treated with NPWT. Aetiology of the wounds was ventral hernia repair (n = 11) and acute abdominal wall defect (n = 10). Prior to NPWT initiation, the mean hospital LOS for the composite, PP and PG meshes were 76 days (range: 21-171 days), 51 days (range: 32-62 days) and 19 days (range: 12-39 days), respectively. The mean hospital LOS following initiation of NPWT for wounds with exposed composite, PP and PG mesh were 28, 31 and 32 days, respectively. Eighteen of the 21 wounds (86%) reached full closure after a mean time of 26 days of NPWT and a mean hospital LOS of 30 days postinitiation of NPWT. Three wounds, all with composite mesh left in situ, did not reach full closure, although all exhibited decreased wound dimensions, granulating beds and decreased surface area exposure of mesh. During NPWT/ROCF, one hypoalbuminemic patient with exposed PP mesh developed an enterocutaneous fistula over a prior enterotomy site. This patient subsequently underwent total mesh extraction, takedown of the fistula and PP mesh replacement followed by reinstitution of NPWT and flap closure. In addition to appropriate systemic antibiotics and nutritional optimisation, the adjunctive use of NPWT resulted in successful closure of 86% of infected abdominal wounds with exposed prosthetic mesh. Patient hospital LOS (except those with PG mesh), operative procedures and readmissions were decreased during NPWT compared with treatment prior to NPWT. Future multi-site prospective, controlled studies would provide a strong evidence base from which treatment decisions could be made in the management of these challenging and costly cases. © 2010 The Authors. © 2010 Blackwell Publishing Ltd and Medicalhelplines.com Inc.
Note: Radial-thrust combo metal mesh foil bearing for microturbomachinery.
Park, Cheol Hoon; Choi, Sang Kyu; Hong, Doo Euy; Yoon, Tae Gwang; Lee, Sung Hwi
2013-10-01
This Note proposes a novel radial-thrust combo metal mesh foil bearing (MMFB). Although MMFBs have advantages such as higher stiffness and damping over conventional air foil bearings, studies related to MMFBs have been limited to radial MMFBs. The novel combo MMFB is composed of a radial top foil, thrust top foils, and a ring-shaped metal mesh damper--fabricated by compressing a copper wire mesh--with metal mesh thrust pads for the thrust bearing at both side faces. In this study, the combo MMFB was fabricated in half-split type to support the rotor for a micro gas turbine generator. The manufacture and assembly process for the half-split-type combo MMFB is presented. In addition, to verify the proposed combo MMFB, motoring test results up to 250,000 rpm and axial displacements as a function of rotational speed are presented.
Issa, Nidal; Ohana, Gil; Bachar, Gil Nissim; Powsner, Eldad
2016-02-01
A totally extraperitoneal (TEP) approach is currently the technique of choice for the laparoscopic repair of bilateral inguinal hernias in our institution. Most other surgeons use two meshes for the TEP repair, one for each side. We prefer a large single mesh when possible since it allows for easier correct placement of the mesh in one stage. We compared our long-term results of both techniques in terms of late complications and recurrence rates. This study retrospectively evaluated the medical records of 108 patients who underwent bilateral laparoscopic TEP repair in our institution between January 2002 and December 2003. Excluded were patients who had a conversion to a transabdominal preperitoneal or open approach. A total of 73 (67 %) patients fulfilled study entrance criteria and were enrolled: 39 had undergone single mesh repair and 34 had undergone double mesh repair. There were no significant group differences in demographics, operating time, postoperative morbidity, or hospital stay. Likewise, after a median follow-up of 102 months (range 94–115 months), there were no significant group differences between the single and double mesh groups in persistent pain (5.8 vs 2.5 %, respectively; p = 0.476) and recurrence (7.6 vs 8.8 %, respectively; p = 0.55). The use of a large single mesh is an effective and safe alternative technique for TEP repair of bilateral inguinal hernias, and is technically easy to perform.
Okeyo, Kennedy Omondi; Kurosawa, Osamu; Yamazaki, Satoshi; Oana, Hidehiro; Kotera, Hidetoshi; Nakauchi, Hiromitsu; Washizu, Masao
2015-10-01
Mechanical methods for inducing differentiation and directing lineage specification will be instrumental in the application of pluripotent stem cells. Here, we demonstrate that minimization of cell-substrate adhesion can initiate and direct the differentiation of human pluripotent stem cells (hiPSCs) into cyst-forming trophoblast lineage cells (TLCs) without stimulation with cytokines or small molecules. To precisely control cell-substrate adhesion area, we developed a novel culture method where cells are cultured on microstructured mesh sheets suspended in a culture medium such that cells on mesh are completely out of contact with the culture dish. We used microfabricated mesh sheets that consisted of open meshes (100∼200 μm in pitch) with narrow mesh strands (3-5 μm in width) to provide support for initial cell attachment and growth. We demonstrate that minimization of cell adhesion area achieved by this culture method can trigger a sequence of morphogenetic transformations that begin with individual hiPSCs attached on the mesh strands proliferating to form cell sheets by self-assembly organization and ultimately differentiating after 10-15 days of mesh culture to generate spherical cysts that secreted human chorionic gonadotropin (hCG) hormone and expressed caudal-related homeobox 2 factor (CDX2), a specific marker of trophoblast lineage. Thus, this study demonstrates a simple and direct mechanical approach to induce trophoblast differentiation and generate cysts for application in the study of early human embryogenesis and drug development and screening.
The Importance of Registries in the Postmarketing Surveillance of Surgical Meshes.
Köckerling, Ferdinand; Simon, Thomas; Hukauf, Martin; Hellinger, Achim; Fortelny, Rene; Reinpold, Wolfgang; Bittner, Reinhard
2017-06-07
To assess the role of registries in the postmarketing surveillance of surgical meshes. To date, surgical meshes are classified as group II medical devices. Class II devices do not require premarket clearance by clinical studies. Ethicon initiated a voluntary market withdrawal of Physiomesh for laparoscopic use after an analysis of unpublished data from the 2 large independent hernia registries-Herniamed German Registry and Danish Hernia Database. This paper now presents the relevant data from the Herniamed Registry. The present analysis compares the prospective perioperative and 1-year follow-up data collected for all patients with incisional hernia who had undergone elective laparoscopic intraperitoneal onlay mesh repair either with Physiomesh (n = 1380) or with other meshes recommended in the guidelines (n = 3834). Patients with Physiomesh repair had a markedly higher recurrence rate compared with the other recommended meshes (12.0% vs 5.0%; P < 0.001). In the multivariable analysis, the recurrence rate was highly significantly influenced by the mesh type used (P < 0.001). If Physiomesh was used, that led to a highly significant increase in the recurrence rate on 1-year follow-up (odds ratio 2.570, 95% CI 2.057, 3.210). The mesh type used also had a significant influence on chronic pain rates. The importance of real-world data for postmarketing surveillance of surgical meshes has been demonstrated in this registry-based study. Randomized controlled trials are needed for premarket approval of new devices. The role of sponsorship of device studies by the manufacturing company must be taken into account.This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0.
Synthetic vaginal mesh for pelvic organ prolapse.
Iglesia, Cheryl B
2011-10-01
The purpose of this review is to summarize recently published comparative trials on synthetic vaginal mesh versus traditional native tissue repairs for pelvic organ prolapse. Although studies suggest benefit from the use of synthetic vaginal mesh for anterior compartment prolapse, data are limited on the use of mesh for posterior and apical prolapse when compared with native tissue repair. The benefits of a more durable repair must be weighed against risks such as the development of de-novo stress incontinence, visceral injury, dyspareunia, pelvic pain and mesh contraction, exposure and extrusion requiring reoperation. Furthermore, the success rates of native tissue repairs are higher than previously considered using updated validated composite outcomes that incorporate both subjective relief of bulge and objective cure defined as prolapse above the hymenal ring. Surgeons placing synthetic mesh for pelvic organ prolapse should counsel patients regarding the potential benefits, risks, and alternatives including native tissue repairs. Level 1 evidence suggests anterior synthetic mesh may be superior to anterior repair. Expert opinion suggests potential benefit of vaginal mesh for recurrences, hysteropexy, and advanced prolapse in patients with medical co-morbidities precluding invasive open and endoscopic sacrocolpopexies; however, comparative clinical trials with long-term data are needed. (C) 2011 Lippincott Williams & Wilkins, Inc.
Prophylactic mesh at end-colostomy construction reduces parastomal hernia rate: a randomized trial.
Lambrecht, J R; Larsen, S G; Reiertsen, O; Vaktskjold, A; Julsrud, L; Flatmark, K
2015-10-01
Parastomal hernia (PSH) is the most common complication of an end-colostomy and about one-quarter of patients need operative repair, which is often unsuccessful. A randomized trial was carried out to compare the results of using mesh or no mesh at the time of formation of a colostomy with the clinical identification of PSH as the primary outcome. In this two-centre randomized trial (Oslo University Hospital and Sykehuset Innlandet Hospital Trust, Norway), patients with rectal cancer undergoing open pelvic surgery were randomized to receive a retromuscular synthetic mesh (study group, n = 32) or no mesh (control group, n = 26) at the time of end-colostomy formation. Postoperative follow up was not blinded and included clinical examination and routine CT. The median period of follow up was 40 (range: 84) months. There were no differences in demographic variables or complications between the study and control groups. PSH developed in two patients of the study group and in 12 of the control group [OR = 0.04 (95% CI: 0.01-0.30) and hazard ratio 0.134 (95% CI: 0.030-0.603); P < 0.001]. The number needed to treat to avoid one PSH was 2.5 patients. CT demonstrated an increase over time in the size of the fascial orifice in patients with PSH without mesh prophylaxis, in contrast to a stable size in patients with mesh and in the control patients who did not develop PSH. The retromuscular insertion of synthetic mesh at the time of formation of an end-colostomy reduced the risk of PSH. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.
Long-term anisotropic mechanical response of surgical meshes used to repair abdominal wall defects.
Hernández-Gascón, B; Peña, E; Pascual, G; Rodríguez, M; Bellón, J M; Calvo, B
2012-01-01
Routine hernia repair surgery involves the implant of synthetic mesh. However, this type of procedure may give rise to pain and bowel incarceration and strangulation, causing considerable patient disability. The purpose of this study was to compare the long-term behaviour of three commercial meshes used to repair the partially herniated abdomen in New Zealand White rabbits: the heavyweight (HW) mesh, Surgipro(®) and lightweight (LW) mesh, Optilene(®), both made of polypropylene (PP), and a mediumweight (MW) mesh, Infinit(®), made of polytetrafluoroethylene (PTFE). The implanted meshes were mechanical and histological assessed at 14, 90 and 180 days post-implant. This behaviour was compared to the anisotropic mechanical behaviour of the unrepaired abdominal wall in control non-operated rabbits. Both uniaxial mechanical tests conducted in craneo-caudal and perpendicular directions and histological findings revealed substantial collagen growth over the repaired hernial defects causing stiffness in the repair zone, and thus a change in the original properties of the meshes. The mechanical behaviour of the healthy tissue in the craneo-caudal direction was not reproduced by any of the implanted meshes after 14 days or 90 days of implant, whereas in the perpendicular direction, SUR and OPT achieved similar behaviour. From a mechanical standpoint, the anisotropic PP-lightweight meshes may be considered a good choice in the long run, which correlates with the structure of the regenerated tissue. Copyright © 2011 Elsevier Ltd. All rights reserved.
Incisional hernia prevention using a cyanoacrilate-fixed retrofascial mesh.
Hoyuela, Carlos; Juvany, Montserrat; Trias, Miquel; Ardid, Jordi; Martrat, Antoni
2018-01-01
The rate of incisional hernia in high-risk patients (obesity, cancer, etc.) is high, even in laparoscopic surgery. The aim of this study is to evaluate the safety of the use of cyanoacrylate fixed prophylactic meshes in the assistance incision in overweight or obese patients undergoing laparoscopic colorectal surgery. A prospective, non-randomized cohort study of patients undergoing elective laparoscopic resection for colorectal cancer between January 2013 and March 2016 was performed. Those with a body mass index greater than 25kg / m 2 were evaluated to implant a prophylactic meshes fixed with cyanoacrylate (Histoacryl®) as reinforcement of the assistance incision. 52 patients were analyzed (mean body mass index: 28.4±2kg / m 2 ). Prophylactic meshes was implanted in 15 patients. The time to put the mesh in place was always less than 5minutes. There was no significant difference in wound infection rate (12% vs. 10%). No mesh had to be explanted. Although the mean follow-up was shorter (14.1±4 vs. 22.3±9 months), there were no incisional hernia in the mesh group. On the other hand, in the non-mesh group, 1 acute evisceration (2.7%) and 4 incisional hernia of the assistance incision were observed (10.8%). There were no significant differences between groups regarding trocar incisional hernia (6.6 vs. 5.4%). The implantation of a reinforcement prophylactic mesh in overweight or obese patients undergoing laparoscopic colorectal surgery is safe and seems to reduce the short-term rate of incisional hernia. Fixation with cyanoacrylate is a rapid method that facilitates the procedure without additional complications. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Glazener, Cathryn; Breeman, Suzanne; Elders, Andrew; Hemming, Christine; Cooper, Kevin; Freeman, Robert; Smith, Anthony; Hagen, Suzanne; Montgomery, Isobel; Kilonzo, Mary; Boyers, Dwayne; McDonald, Alison; McPherson, Gladys; MacLennan, Graeme; Norrie, John
2016-12-01
The use of mesh in prolapse surgery is controversial, leading to a number of enquiries into its safety and efficacy. To compare synthetic non-absorbable mesh inlay, biological graft and mesh kit with a standard repair in terms of clinical effectiveness, adverse effects, quality of life (QoL), costs and cost-effectiveness. Two randomised controlled trials within a comprehensive cohort (CC) study. Allocation was by a remote web-based randomisation system in a 1 :1 : 1 ratio (Primary trial) or 1 : 1 : 2 ratio (Secondary trial), and was minimised on age, type of prolapse repair planned, need for a concomitant continence procedure, need for a concomitant upper vaginal prolapse procedure and surgeon. Participants and outcome assessors were blinded to randomisation; participants were unblinded if they requested the information. Surgeons were not blinded to allocated procedure. Thirty-five UK hospitals. Primary study : 2474 women in the analysis (including 1348 randomised) having primary anterior or posterior prolapse surgery. Secondary study : 398 in the analysis (including 154 randomised) having repeat anterior or posterior prolapse surgery. CC3 : 215 women having either uterine or vault prolapse repair. Anterior or posterior repair alone, or with mesh inlay, biological graft or mesh kit. Prolapse symptoms [Pelvic Organ Prolapse Symptom Score (POP-SS)]; prolapse-specific QoL; cost-effectiveness [incremental cost per quality-adjusted life-year (QALY)]. Primary trials : adjusting for baseline and minimisation covariates, mean POP-SS was similar for each comparison {standard 5.4 [standard deviation (SD) 5.5] vs. mesh 5.5 (SD 5.1), mean difference (MD) 0.00, 95% confidence interval (CI) -0.70 to 0.71; standard 5.5 (SD 5.6) vs. graft 5.6 (SD 5.6), MD -0.15, 95% CI -0.93 to 0.63}. Serious non-mesh adverse effects rates were similar between the groups in year 1 [standard 7.2% vs. mesh 7.8%, risk ratio (RR) 1.08, 95% CI 0.68 to 1.72; standard 6.3% vs. graft 9.8%, RR 1.57, 95% CI 0.95 to 2.59]. There were no statistically significant differences between groups in any other outcome measure. The cumulative mesh complication rates over 2 years were 2 of 430 (0.5%) for standard repair (trial 1), 46 of 435 (10.6%) for mesh inlay and 2 of 368 (0.5%) for biological graft. The CC findings were comparable. Incremental costs were £363 (95% CI -£32 to £758) and £565 (95% CI £180 to £950) for mesh and graft vs. standard, respectively. Incremental QALYs were 0.071 (95% CI -0.004 to 0.145) and 0.039 (95% CI -0.041 to 0.120) for mesh and graft vs. standard, respectively. A Markov decision model extrapolating trial results over 5 years showed standard repair had the highest probability of cost-effectiveness, but results were surrounded by considerable uncertainty. Secondary trials : there were no statistically significant differences between the randomised groups in any outcome measure, but the sample size was too small to be conclusive. The cumulative mesh complication rates over 2 years were 7 of 52 (13.5%) for mesh inlay and 4 of 46 (8.7%) for mesh kit, with no mesh exposures for standard repair. In women who were having primary repairs, there was evidence of no benefit from the use of mesh inlay or biological graft compared with standard repair in terms of efficacy, QoL or adverse effects (other than mesh complications) in the short term. The Secondary trials were too small to provide conclusive results. Women in the Primary trials included some with a previous repair in another compartment. Follow-up is vital to identify any long-term potential benefits and serious adverse effects. Long-term follow-up to at least 6 years after surgery is ongoing to identify recurrence rates, need for further prolapse surgery, adverse effects and cost-effectiveness. Current Controlled Trials ISRCTN60695184. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 20, No. 95. See the NIHR Journals Library website for further project information.
Cheng, X Y; Li, S J; Murr, L E; Zhang, Z B; Hao, Y L; Yang, R; Medina, F; Wicker, R B
2012-12-01
Ti-6Al-4V alloy with two kinds of open cellular structures of stochastic foam and reticulated mesh was fabricated by additive manufacturing (AM) using electron beam melting (EBM), and microstructure and mechanical properties of these samples with high porosity in the range of 62%∼92% were investigated. Optical observations found that the cell struts and ligaments consist of primary α' martensite. These cellular structures have comparable compressive strength (4∼113 MPa) and elastic modulus (0.2∼6.3 GPa) to those of trabecular and cortical bone. The regular mesh structures exhibit higher specific strength than other reported metallic foams under the condition of identical specific stiffness. During the compression, these EBM samples have a brittle response and undergo catastrophic failure after forming crush band at their peak loading. These bands have identical angle of ∼45° with compression axis for the regular reticulated meshes and such failure phenomenon was explained by considering the cell structure. Relative strength and density follow a linear relation as described by the well-known Gibson-Ashby model but its exponential factor is ∼2.2, which is relative higher than the idea value of 1.5 derived from the model. Copyright © 2012 Elsevier Ltd. All rights reserved.
Fet, N; Alizai, P H; Fragoulis, A; Wruck, C; Pufe, T; Tolba, R H; Neumann, U P; Klinge, U
2014-06-01
Hernia repair with prosthetic meshes represents one of the most common surgical procedures in the field of surgery. This intervention is always associated with an ensuing inflammatory response, angiogenesis and fibrotic encapsulation forming a foreign body granuloma (FBG) around the mesh fibres. Several studies have described this inflammatory reaction by characterising inflammatory cell infiltrate around the FBG after mesh explantation. However, very little is known about the real-time progression of such an inflammatory response. The aim of this study was to investigate the feasibility of monitoring the ongoing inflammatory response to mesh implantation using bioluminescence in vivo. Three luciferase transgenic mice strains (FVB/N-Tg(Vegfr2-luc)-Xen, BALB/C-Tg(NFκB-RE-luc)-Xen and Tg(INS/EpRE-Luc)T20Rbl) were used. Mice were anaesthetized with 2 % isoflurane, and two incisions were made on the left and right sides of the abdomen of the mice. A 1-cm(2) propylene mesh was implanted subcutaneously in the right incision wound of each mouse, and the left wound served as control. Two hundred microliters of D-luciferin was injected into the mice, and bioluminescence measurements were done prior to the surgical intervention and subsequently every 3 days. After mesh explantation, histological analysis was done. Statistical analysis was done using prism GraphPad software. Bioluminescence results revealed different time points of maximum signal for the different mice strains. VEGFR2 gene expression peaked on day 6, NFkB on day 12 and ARE on day 3 post mesh implantation. We also observed much higher bioluminescent signal around the FBG surrounding the mesh as compared to the control wound, with p < 0.05 for all the different mice strains. Our results prove the possibility of monitoring the inflammatory reaction after mesh implantation in vivo using bioluminescence signal release. This provides a novel method of accessing and accurately describing the ongoing inflammatory response over a given period of time.
Box truss analysis and technology development. Task 1: Mesh analysis and control
NASA Technical Reports Server (NTRS)
Bachtell, E. E.; Bettadapur, S. S.; Coyner, J. V.
1985-01-01
An analytical tool was developed to model, analyze and predict RF performance of box truss antennas with reflective mesh surfaces. The analysis system is unique in that it integrates custom written programs for cord tied mesh surfaces, thereby drastically reducing the cost of analysis. The analysis system is capable of determining the RF performance of antennas under any type of manufacturing or operating environment by integrating together the various disciplines of design, finite element analysis, surface best fit analysis and RF analysis. The Integrated Mesh Analysis System consists of six separate programs: The Mesh Tie System Model Generator, The Loadcase Generator, The Model Optimizer, The Model Solver, The Surface Topography Solver and The RF Performance Solver. Additionally, a study using the mesh analysis system was performed to determine the effect of on orbit calibration, i.e., surface adjustment, on a typical box truss antenna.
Effect of ground control mesh on dust sampling and explosion mitigation.
Alexander, D W; Chasko, L L
2015-07-01
Researchers from the National Institute for Occupational Safety and Health's Office of Mine Safety and Health Research conducted an assessment of the effects that ground control mesh might have on rock and float coal dust distribution in a coal mine. The increased use of mesh to control roof and rib spall introduces additional elevated surfaces on which rock or coal dust can collect. It is possible to increase the potential for dust explosion propagation if any float coal dust is not adequately inerted. In addition, the mesh may interfere with the collection of representative dust samples when using the pan-and-brush sampling method developed by the U.S. Bureau of Mines and used by the Mine Safety and Health Administration for band sampling. This study estimates the additional coal or rock dust that could accumulate on mesh and develops a means to collect representative dust samples from meshed entries.
The continuing challenge of parastomal hernia: failure of a novel polypropylene mesh repair.
Morris-Stiff, G.; Hughes, L. E.
1998-01-01
In an attempt to reduce the high recurrence rate after repair of parastomal hernia, a technique was devised in which non-absorbable mesh was used to provide a permanent closure of the gap between the emerging bowel and abdominal wall. Seven patients were treated during the period 1990-1992. Five-year follow-up has given disappointing results, with recurrent hernia in 29% of cases and serious complications, including obstruction and dense adhesions to the intra-abdominal mesh, in 57% and a mesh-related abscess in 15% of cases. This study highlights a dual problem--failure of a carefully sutured mesh to maintain an occlusive position, and complications of the mesh itself. The poor results obtained with this technique together with the disappointing results with other methods described in the literature confirms that parastomal hernia presents a continuing challenge. Images Figure 1 Figure 2 PMID:9682640
Effect of ground control mesh on dust sampling and explosion mitigation
Alexander, D.W.; Chasko, L.L.
2017-01-01
Researchers from the National Institute for Occupational Safety and Health’s Office of Mine Safety and Health Research conducted an assessment of the effects that ground control mesh might have on rock and float coal dust distribution in a coal mine. The increased use of mesh to control roof and rib spall introduces additional elevated surfaces on which rock or coal dust can collect. It is possible to increase the potential for dust explosion propagation if any float coal dust is not adequately inerted. In addition, the mesh may interfere with the collection of representative dust samples when using the pan-and-brush sampling method developed by the U.S. Bureau of Mines and used by the Mine Safety and Health Administration for band sampling. This study estimates the additional coal or rock dust that could accumulate on mesh and develops a means to collect representative dust samples from meshed entries. PMID:28936000
Computations of Aerodynamic Performance Databases Using Output-Based Refinement
NASA Technical Reports Server (NTRS)
Nemec, Marian; Aftosmis, Michael J.
2009-01-01
Objectives: Handle complex geometry problems; Control discretization errors via solution-adaptive mesh refinement; Focus on aerodynamic databases of parametric and optimization studies: 1. Accuracy: satisfy prescribed error bounds 2. Robustness and speed: may require over 105 mesh generations 3. Automation: avoid user supervision Obtain "expert meshes" independent of user skill; and Run every case adaptively in production settings.
NASA Technical Reports Server (NTRS)
Woodard, Paul R.; Batina, John T.; Yang, Henry T. Y.
1992-01-01
Quality assessment procedures are described for two-dimensional unstructured meshes. The procedures include measurement of minimum angles, element aspect ratios, stretching, and element skewness. Meshes about the ONERA M6 wing and the Boeing 747 transport configuration are generated using an advancing front method grid generation package of programs. Solutions of Euler's equations for these meshes are obtained at low angle-of-attack, transonic conditions. Results for these cases, obtained as part of a validation study demonstrate accuracy of an implicit upwind Euler solution algorithm.
Anisotropic mesh adaptation for marine ice-sheet modelling
NASA Astrophysics Data System (ADS)
Gillet-Chaulet, Fabien; Tavard, Laure; Merino, Nacho; Peyaud, Vincent; Brondex, Julien; Durand, Gael; Gagliardini, Olivier
2017-04-01
Improving forecasts of ice-sheets contribution to sea-level rise requires, amongst others, to correctly model the dynamics of the grounding line (GL), i.e. the line where the ice detaches from its underlying bed and goes afloat on the ocean. Many numerical studies, including the intercomparison exercises MISMIP and MISMIP3D, have shown that grid refinement in the GL vicinity is a key component to obtain reliable results. Improving model accuracy while maintaining the computational cost affordable has then been an important target for the development of marine icesheet models. Adaptive mesh refinement (AMR) is a method where the accuracy of the solution is controlled by spatially adapting the mesh size. It has become popular in models using the finite element method as they naturally deal with unstructured meshes, but block-structured AMR has also been successfully applied to model GL dynamics. The main difficulty with AMR is to find efficient and reliable estimators of the numerical error to control the mesh size. Here, we use the estimator proposed by Frey and Alauzet (2015). Based on the interpolation error, it has been found effective in practice to control the numerical error, and has some flexibility, such as its ability to combine metrics for different variables, that makes it attractive. Routines to compute the anisotropic metric defining the mesh size have been implemented in the finite element ice flow model Elmer/Ice (Gagliardini et al., 2013). The mesh adaptation is performed using the freely available library MMG (Dapogny et al., 2014) called from Elmer/Ice. Using a setup based on the inter-comparison exercise MISMIP+ (Asay-Davis et al., 2016), we study the accuracy of the solution when the mesh is adapted using various variables (ice thickness, velocity, basal drag, …). We show that combining these variables allows to reduce the number of mesh nodes by more than one order of magnitude, for the same numerical accuracy, when compared to uniform mesh refinement. For transient solutions where the GL is moving, we have implemented an algorithm where the computation is reiterated allowing to anticipate the GL displacement and to adapt the mesh to the transient solution. We discuss the performance and robustness of this algorithm.
Transrectal Mesh Erosion Requiring Bowel Resection.
Kemp, Marta Maria; Slim, Karem; Rabischong, Benoît; Bourdel, Nicolas; Canis, Michel; Botchorishvili, Revaz
To report a case of a transrectal mesh erosion as complication of laparoscopic promontofixation with mesh repair, necessitating bowel resection and subsequent surgical interventions. Sacrocolpopexy has become a standard procedure for vaginal vault prolapse [1], and the laparoscopic approach has gained popularity owing to more rapid recovery and less morbidity [2,3]. Mesh erosion is a well-known complication of surgical treatment for prolapse as reported in several negative evaluations, including a report from the US Food and Drug Administration in 2011 [4]. Mesh complications are more common after surgeries via the vaginal approach [5]; nonetheless, the incidence of vaginal mesh erosion after laparoscopic procedures is as high as 9% [6]. The incidence of transrectal mesh exposure after laparoscopic ventral rectopexy is roughly 1% [7]. The diagnosis may be delayed because of its rarity and variable presentation. In addition, polyester meshes, such as the mesh used in this case, carry a higher risk of exposure [8]. A 57-year-old woman experiencing genital prolapse, with the cervix classified as +3 according to the Pelvic Organ Prolapse Quantification system, underwent laparoscopic standard sacrocolpopexy using polyester mesh. Subtotal hysterectomy and bilateral adnexectomy were performed concomitantly. A 3-year follow-up consultation demonstrated no signs or symptoms of erosion of any type. At 7 years after the surgery, however, the patient presented with rectal discharge, diagnosed as infectious rectocolitis with the isolation of Clostridium difficile. She underwent a total of 5 repair surgeries in a period of 4 months, including transrectal resection of exposed mesh, laparoscopic ablation of mesh with digestive resection, exploratory laparoscopy with abscess drainage, and exploratory laparoscopy with ablation of residual mesh and transverse colostomy. She recovered well after the last intervention, exhibiting no signs of vaginal or rectal fistula and no recurrence of pelvic floor descent. Her intestinal transit was reestablished, and she was satisfied with the treatment. None of the studies that represent the specific female population submitted to laparoscopic promontofixation with transrectal mesh erosion describe the need for more than one intervention or digestive resection [9-12]. Physicians dealing with patients submitted to pelvic reconstructive surgeries with mesh placement should be aware of transrectal and other nonvaginal erosions of mesh, even being rare events. Moreover, they should perform an active search for unusual gynecologic and anorectal signs and symptoms. Most importantly, patients undergoing mesh repair procedures must be warned of the risks of the surgery, including the possibility of several subsequent interventions. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.
Probing the gas density in our Galactic Centre: moving mesh simulations of G2
NASA Astrophysics Data System (ADS)
Steinberg, Elad; Sari, Re'em; Gnat, Orly; Gillessen, Stefan; Plewa, Philipp; Genzel, Reinhard; Eisenhauer, Frank; Ott, Thomas; Pfuhl, Oliver; Habibi, Maryam; Waisberg, Idel; von Fellenberg, Sebastiano; Dexter, Jason; Bauböck, Michi; Rosales, Alejandra Jimenez
2018-01-01
The G2 object has recently passed its pericentre passage in our Galactic Centre. While the Brγ emission shows clear signs of tidal interaction, the change in the observed luminosity is only of about a factor of 2, in contention with all previous predictions. We present high-resolution simulations performed with the moving mesh code, RICH, together with simple analytical arguments that reproduce the observed Brγ emission. In our model, G2 is a gas cloud that undergoes tidal disruption in a dilute ambient medium. We find that during pericentre passage, the efficient cooling of the cloud results in a vertical collapse, compressing the cloud by a factor of ∼5000. By properly taking into account the ionization state of the gas, we find that the cloud is UV starved and are able to reproduce the observed Brγ luminosity. For densities larger than ≈500 cm-3 at pericentre, the cloud fragments due to cooling instabilities and the emitted radiation is inconsistent with observations. For lower densities, the cloud survives the pericentre passage intact and its emitted radiation matches the observed light curve. From the duration of Brγ emission that contains both redshifted and blueshifted components, we show that the cloud is not spherical but rather elongated with a size ratio of 4 at year 2001. The simulated cloud's elongation grows as it travels towards pericentre and is consistent with observations, due to viewing angles. The simulation is also consistent with having a spherical shape at apocentre.
NASA Astrophysics Data System (ADS)
Fu, Yubin; Liu, Jia; Su, Jia; Zhao, Zhongkai; Liu, Yang; Xu, Qian
2012-03-01
Microbial fuel cell (MFC) on the ocean floor is a kind of novel energy- harvesting device that can be developed to drive small instruments to work continuously. The shape of electrode has a great effect on the performance of the MFC. In this paper, several shapes of electrode and cell structure were designed, and their performance in MFC were compared in pairs: Mesh (cell-1) vs. flat plate (cell-2), branch (cell-3) vs. cylinder (cell-4), and forest (cell-5) vs. disk (cell-6) FC. Our results showed that the maximum power densities were 16.50, 14.20, 19.30, 15.00, 14.64, and 9.95 mWm-2 for cell-1, 2, 3, 4, 5 and 6 respectively. And the corresponding diffusion-limited currents were 7.16, 2.80, 18.86, 10.50, 18.00, and 6.900 mA. The mesh and branch anodes showed higher power densities and much higher diffusion-limited currents than the flat plate and the cylinder anodes respectively due to the low diffusion hindrance with the former anodes. The forest cathode improved by 47% of the power density and by 161% of diffusion-limited current than the disk cathode due to the former's extended solid/liquid/gas three-phase boundary. These results indicated that the shape of electrode is a major parameter that determining the diffusion-limited current of an MFC, and the differences in the electrode shape lead to the differences in cell performance. These results would be useful for MFC structure design in practical applications.
Lee, Lawrence; Saleem, Abdulaziz; Landry, Tara; Latimer, Eric; Chaudhury, Prosanto; Feldman, Liane S
2014-01-01
Parastomal hernia (PSH) is common after stoma formation. Studies have reported that mesh prophylaxis reduces PSH, but there are no cost-effectiveness data. Our objective was to determine the cost effectiveness of mesh prophylaxis vs no prophylaxis to prevent PSH in patients undergoing abdominoperineal resection with permanent colostomy for rectal cancer. Using a cohort Markov model, we modeled the costs and effectiveness of mesh prophylaxis vs no prophylaxis at the index operation in a cohort of 60-year-old patients undergoing abdominoperineal resection for rectal cancer during a time horizon of 5 years. Costs were expressed in 2012 Canadian dollars (CAD$) and effectiveness in quality-adjusted life years. Deterministic and probabilistic sensitivity analyses were performed. In patients with stage I to III rectal cancer, prophylactic mesh was dominant (less costly and more effective) compared with no mesh. In patients with stage IV disease, mesh prophylaxis was associated with higher cost (CAD$495 more) and minimally increased effectiveness (0.05 additional quality-adjusted life years), resulting in an incremental cost-effectiveness ratio of CAD$10,818 per quality-adjusted life year. On sensitivity analyses, the decision was sensitive to the probability of mesh infection and the cost of the mesh, and method of diagnosing PSH. In patients undergoing abdominoperineal resection with permanent colostomy for rectal cancer, mesh prophylaxis might be the less costly and more effective strategy compared with no mesh to prevent PSH in patients with stage I to III disease, and might be cost effective in patients with stage IV disease. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Wang, Shuanhu; Wang, Wenbin; Zhu, Bing; Song, Guolei; Jiang, Congqiao
2016-10-01
Parastomal hernia is a very common complication after colostomy, especially end-colostomy. It is unclear whether prophylactic placement of mesh at the time of stoma formation could prevent parastomal hernia formation after surgery for rectal cancer. A systematic review and meta-analysis were conducted to evaluate the efficacy of prophylactic mesh in end-colostomy construction. PubMed, Embase, and the Cochrane Library were searched, covering records entered from their inception to September 2015. Randomized controlled trials (RCTs) comparing stoma with mesh to stoma without mesh after surgery for rectal cancer were included. The primary outcome was the incidence of parastomal hernia. Pooled risk ratios (RR) with 95 % confidence intervals (CI) were obtained using random effects models. Six RCTs containing 309 patients were included. Parastomal hernia occurred in 24.4 % (38 of 156) of patients with mesh and 50.3 % (77 of 153) of patients without mesh. Meta-analysis showed a lower incidence of parastomal hernia (RR, 0.42; 95 % CI 0.22-0.82) and reoperation related to parastomal hernia (RR, 0.23; 95 % CI 0.06-0.89) in patients with mesh. Stoma-related morbidity was similar between mesh group and non-mesh group (RR, 0.65; 95 % CI 0.33-1.30). Prophylactic placement of a mesh at the time of a stoma formation seems to be associated with a significant reduction in the incidence of parastomal hernia and reoperation related to parastomal hernia after surgery for rectal cancer, but not the rate of stoma-related morbidity. However, the results should be interpreted with caution because of the heterogeneity among the studies.
Long-term follow-up of treatment for synthetic mesh complications.
Hansen, Brooke L; Dunn, Guinn Ellen; Norton, Peggy; Hsu, Yvonne; Nygaard, Ingrid
2014-01-01
The objectives of this study are (1) to describe the presenting symptoms, findings, and treatment and (2) to describe the self-reported improvement and function at least 6 months after presentation in women presenting to 1 urogynecology division for complications associated with synthetic vaginal mesh. Women evaluated between 2006 and 2011 were identified by diagnostic codes. We abstracted information from the medical record and attempted to contact all women to complete a follow-up telephone survey questionnaire consisting of several validated instruments. A total of 111 women were evaluated for complications associated with synthetic vaginal mesh. The mean interval from index surgery was 2.4 years. Of these, 84% were referred from outside hospitals. Index surgeries included vaginal mesh kits/vaginally placed mesh (47%), midurethral mesh slings (37%), abdominally placed vaginal mesh (11%), and vaginal mesh kit with concomitantly placed mesh sling (5%). The most common complications were extrusion (65%), contraction (17%), and chronic pelvic pain (16%). A total of 98 women underwent some type of treatment (85 surgical) by urogynecologists, pelvic pain specialists, or physical therapists. Eighty-four (76%) provided follow-up information at mean interval since presentation of 2.3 years. At follow-up, the mean (SD) Pelvic Floor Distress Inventory score was 98 (67), the mean (SD) EQ-5D index score was 0.69 (0.23), and 22% reported vaginal discharge, 15% vaginal bleeding or spotting, and 45% sexual abstinence due to problems related to mesh. A total of 71% reported being overall better, whereas 29% were the same or worse. Two years after tertiary care level multidisciplinary treatment of vaginal mesh complications, many women still report symptoms that negatively impact their quality of life.
Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model
Soltz, Barbara A.; Stadler, Istvan; Soltz, Robert
2009-01-01
Background and Objectives: Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. Methods: Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45µ, 4.5W CW, 5mm spot, and 55°C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. Results: The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. Discussion and Conclusion: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted. PMID:19660214
Resterilized mesh in repair of abdominal wall defects in rats.
Sucullu, Ilker; Akin, Mehmet Levhi; Yitgin, Selahattin; Filiz, Ali Ilker; Kurt, Yavuz
2008-01-01
A variety of negative opinions about repeated usage of relatively expensive resterilized synthetic meshes have been considered. It had been stated that resterilized polypropylene meshes inhibits fibroblastic activity, decreases proliferative activity, and increases apoptosis in human fibroblast culture, in vitro. The purpose of this study is the in vivo evaluation of the resterilized mesh repairs of abdominal hernia defects in rat models of incisional hernia by comparing primer repair and original mesh repairs. The rats (n = 22) were separated into three groups. While the abdominal defect was repaired by primary suture in the control group (CG), the defects were repaired by original mesh (OG) or resterilized mesh (RG) in mesh-repaired groups. After 21 days, the rats were evaluated for tissue tensile strengths, tissue hydroxyproline levels, tissue inflammation, fibrosis, and apoptosis. Although the tensile strengths in OG and RG were significantly higher than those of CG (p < .05 and p < .05), there was no significant difference between two groups. The tissue hydroxyproline levels in OG and RG were also higher than those of CG. The difference was not significant between the two groups. The inflammation and fibrosis indexes in OG and RG were significantly higher than those of CG (p < .0001 for both), but there was no difference between groups. While the apoptosis index in OG and RG was also higher than that of CG (p < .0001 for both), there was no significant difference between OG and RG. The usage of resterilized mesh in abdominal wall repair did not reduce the tissue tensile strength, did not affect the tissue hydroxyproline levels, did not decrease the fibrosis, and did not increase the tissue inflammation and apoptosis. In conclusion, usage of resterilized meshes in abdominal wall defects was as safe as sterilized meshes.
NASA Astrophysics Data System (ADS)
Tachibana, Kunihide; Nakamura, Toshihiro; Kawasaki, Mitsuo; Morita, Tatsuo; Umekawa, Toyofumi; Kawasaki, Masahiro
2018-01-01
We measured water molecule (H2O) density by tunable diode-laser absorption spectroscopy (TDLAS) for applications in dielectric barrier discharges (DBDs) with a gas-water interface. First, the effects of water temperature and presence of gas flow were tested using a Petri dish filled with water and a gas injection nozzle. Second, the TDLAS system was applied to the measurements of H2O density in two types of DBDs; one was a normal (non-inverted) type with a dielectric-covered electrode above a water-filled counter electrode and the other was an inverted type with a water-suspending mesh electrode above a dielectric-covered counter electrode. The H2O density in the normal DBD was close to the density estimated from the saturated vapor pressure, whereas the density in the inverted DBD was about half of that in the former type. The difference is attributed to the upward gas flow in the latter type, that pushes the water molecules up towards the gas-water interface.
Zhou, Tao; Hong, Guosong; Fu, Tian-Ming; Yang, Xiao; Schuhmann, Thomas G.; Viveros, Robert D.; Lieber, Charles M.
2017-01-01
Implantation of electrical probes into the brain has been central to both neuroscience research and biomedical applications, although conventional probes induce gliosis in surrounding tissue. We recently reported ultraflexible open mesh electronics implanted into rodent brains by syringe injection that exhibit promising chronic tissue response and recording stability. Here we report time-dependent histology studies of the mesh electronics/brain-tissue interface obtained from sections perpendicular and parallel to probe long axis, as well as studies of conventional flexible thin-film probes. Confocal fluorescence microscopy images of the perpendicular and parallel brain slices containing mesh electronics showed that the distribution of astrocytes, microglia, and neurons became uniform from 2–12 wk, whereas flexible thin-film probes yield a marked accumulation of astrocytes and microglia and decrease of neurons for the same period. Quantitative analyses of 4- and 12-wk data showed that the signals for neurons, axons, astrocytes, and microglia are nearly the same from the mesh electronics surface to the baseline far from the probes, in contrast to flexible polymer probes, which show decreases in neuron and increases in astrocyte and microglia signals. Notably, images of sagittal brain slices containing nearly the entire mesh electronics probe showed that the tissue interface was uniform and neurons and neurofilaments penetrated through the mesh by 3 mo postimplantation. The minimal immune response and seamless interface with brain tissue postimplantation achieved by ultraflexible open mesh electronics probes provide substantial advantages and could enable a wide range of opportunities for in vivo chronic recording and modulation of brain activity in the future. PMID:28533392
Yu, Sang-Hui; Cho, Hye-Won; Oh, Seunghan; Bae, Ji-Myung
2015-06-01
No study has yet evaluated the strength of complete dentures reinforced with glass fiber meshes with different content and structures. The purpose of this study was to compare the reinforcing effects of glass fiber mesh with different content and structures with that of metal mesh in complete dentures. Two types of glass fiber mesh were used: SES mesh (SES) and glass cloth (GC2, GC3, and GC4). A metal mesh was used for comparison. The complete dentures were made by placing the reinforcement 1 mm away from the tissue surface. A control group was prepared without any reinforcement (n=10). The compressive properties were measured by a universal testing machine at a crosshead speed of 5 mm/min. The results were analyzed with the Kruskal-Wallis test and the Duncan multiple range test (α=.05). The fracture resistance of the SES group was significantly higher than that of the control, GC4, and metal groups (asymptotic P=.004), but not significantly different from the GC2 and GC3 groups. The toughness of the SES and GC3 groups was significantly higher than that of the others (asymptotic P<.001), but not significantly different from that of the GC4 group. SES and GC3, which have different structures but similar volume content, were the most effective in reinforcing complete dentures. The content of the glass fiber mesh seemed more important than the structures. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Zhou, Tao; Hong, Guosong; Fu, Tian-Ming; Yang, Xiao; Schuhmann, Thomas G; Viveros, Robert D; Lieber, Charles M
2017-06-06
Implantation of electrical probes into the brain has been central to both neuroscience research and biomedical applications, although conventional probes induce gliosis in surrounding tissue. We recently reported ultraflexible open mesh electronics implanted into rodent brains by syringe injection that exhibit promising chronic tissue response and recording stability. Here we report time-dependent histology studies of the mesh electronics/brain-tissue interface obtained from sections perpendicular and parallel to probe long axis, as well as studies of conventional flexible thin-film probes. Confocal fluorescence microscopy images of the perpendicular and parallel brain slices containing mesh electronics showed that the distribution of astrocytes, microglia, and neurons became uniform from 2-12 wk, whereas flexible thin-film probes yield a marked accumulation of astrocytes and microglia and decrease of neurons for the same period. Quantitative analyses of 4- and 12-wk data showed that the signals for neurons, axons, astrocytes, and microglia are nearly the same from the mesh electronics surface to the baseline far from the probes, in contrast to flexible polymer probes, which show decreases in neuron and increases in astrocyte and microglia signals. Notably, images of sagittal brain slices containing nearly the entire mesh electronics probe showed that the tissue interface was uniform and neurons and neurofilaments penetrated through the mesh by 3 mo postimplantation. The minimal immune response and seamless interface with brain tissue postimplantation achieved by ultraflexible open mesh electronics probes provide substantial advantages and could enable a wide range of opportunities for in vivo chronic recording and modulation of brain activity in the future.
Kolambkar, Yash M.; Bajin, Mehmet; Wojtowicz, Abigail; Hutmacher, Dietmar W.; García, Andrés J.
2014-01-01
Electrospun nanofiber meshes have emerged as a new generation of scaffold membranes possessing a number of features suitable for tissue regeneration. One of these features is the flexibility to modify their structure and composition to orchestrate specific cellular responses. In this study, we investigated the effects of nanofiber orientation and surface functionalization on human mesenchymal stem cell (hMSC) migration and osteogenic differentiation. We used an in vitro model to examine hMSC migration into a cell-free zone on nanofiber meshes and mitomycin C treatment to assess the contribution of proliferation to the observed migration. Poly (ɛ-caprolactone) meshes with oriented topography were created by electrospinning aligned nanofibers on a rotating mandrel, while randomly oriented controls were collected on a stationary collector. Both aligned and random meshes were coated with a triple-helical, type I collagen-mimetic peptide, containing the glycine-phenylalanine-hydroxyproline-glycine-glutamate-arginine (GFOGER) motif. Our results indicate that nanofiber GFOGER peptide functionalization and orientation modulate cellular behavior, individually, and in combination. GFOGER significantly enhanced the migration, proliferation, and osteogenic differentiation of hMSCs on nanofiber meshes. Aligned nanofiber meshes displayed increased cell migration along the direction of fiber orientation compared to random meshes; however, fiber alignment did not influence osteogenic differentiation. Compared to each other, GFOGER coating resulted in a higher proliferation-driven cell migration, whereas fiber orientation appeared to generate a larger direct migratory effect. This study demonstrates that peptide surface modification and topographical cues associated with fiber alignment can be used to direct cellular behavior on nanofiber mesh scaffolds, which may be exploited for tissue regeneration. PMID:24020454
Castroviejo-Royo, F; Rodríguez-Toves, L A; Martínez-Sagarra-Oceja, J M; Conde-Redondo, C; Mainez-Rodríguez, J A
2015-04-01
The objective of this study was to determine the efficacy as well as the complications associated with transurethral removal (TUR) of intravesical mesh after suburethral sling, transobturator tape-TOT (Monarc™) or "minisling" (MiniArc(®)), in the treatment of female urinary stress incontinence (USI). retrospective and consecutive study on 9 women with bladder perforation after midurethral slings (3 Monarc™ and 6 MiniArc®) placement for urinary stress incontinence. To remove the mesh, transurethral resection with an electrode loop (TUR-E) was used. The technique included: location and total removal of mesh with bipolar resectoscope up to healthy tissue. The median age was 61 years (49-70 years). The median time between midurethral sling placement and onset the sympltoms was 13 months (1-79 months). and between sling placement and mesh removal was 16 months (1-91 months). Five women (55.5%) developed bladder stones. Mean operating time was 29.4 ± 10.4 minutes and mean length of hospital stay was 2.6 ± 0.5 days. The median follow-up after mesh removal was 38 months (range, 14 to 109 months). No complications were found. The use of transurethral resection of intravesical mesh after suburethral slings is easy and the results obtained by our surgical team are excellent. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Astrophysics Data System (ADS)
Xin, Qin; Yao, Xiaolan; Engelstad, Paal E.
2010-09-01
Wireless Mesh Networking is an emerging communication paradigm to enable resilient, cost-efficient and reliable services for the future-generation wireless networks. We study here the minimum-latency communication primitive of gossiping (all-to-all communication) in multi-hop ad-hoc Wireless Mesh Networks (WMNs). Each mesh node in the WMN is initially given a message and the objective is to design a minimum-latency schedule such that each mesh node distributes its message to all other mesh nodes. Minimum-latency gossiping problem is well known to be NP-hard even for the scenario in which the topology of the WMN is known to all mesh nodes in advance. In this paper, we propose a new latency-efficient approximation scheme that can accomplish gossiping task in polynomial time units in any ad-hoc WMN under consideration of Large Interference Range (LIR), e.g., the interference range is much larger than the transmission range. To the best of our knowledge, it is first time to investigate such a scenario in ad-hoc WMNs under LIR, our algorithm allows the labels (e.g., identifiers) of the mesh nodes to be polynomially large in terms of the size of the WMN, which is the first time that the scenario of large labels has been considered in ad-hoc WMNs under LIR. Furthermore, our gossiping scheme can be considered as a framework which can be easily implied to the scenario under consideration of mobility-related issues since we assume that the mesh nodes have no knowledge on the network topology even for its neighboring mesh nodes.
Cristaudo, Adam; Nayak, Arun; Martin, Sarah; Adib, Reza; Martin, Ian
2015-05-01
The totally extraperitoneal (TEP) approach for surgical repair of inguinal hernias has emerged as a popular technique. We conducted a prospective randomised trial to compare patient comfort scores using different mesh types and fixation using this technique. Over a 14 month period, 146 patients underwent 232 TEP inguinal hernia repairs. We compared the comfort scores of patients who underwent these procedures using different types of mesh and fixation. A non-absorbable 15 × 10 cm anatomical mesh fixed with absorbable tacks (Control group) was compared with either a non-absorbable 15 × 10 cm folding slit mesh with absorbable tacks (Group 2), a partially-absorbable 15 × 10 cm mesh with absorbable tacks (Group 3) or a non-absorbable 15 × 10 cm anatomical mesh fixed with 2 ml fibrin sealant (Group 4). Outcomes were compared at 1, 2, 4 and 12 weeks using the Carolina Comfort Scale (CCS) scores. At 1, 2, 4 and 12 weeks, the median global CCS scores were low for all treatment groups. Statistically significant differences were seen only for median CCS scores and subscores with the use of partially-absorbable mesh with absorbable tacks (Group 3) at weeks 2 and 4. However, these were no longer significant at week 12. In this study, the TEP inguinal hernia repair with minimal fixation results in low CCS scores. There were no statistical differences in CCS scores when comparing types of mesh, configuration of the mesh or fixation methods. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kan, Lijuan; Thayer, Patrick; Fan, Huimin
Electrospun microfiber meshes have been shown to support the proliferation and differentiation of many types of stem cells, but the phenotypic fate of c-kit{sup +} human cardiac stem cells (hCSCs) have not been explored. To this end, we utilized thin (~5 µm) elastomeric meshes consisting of aligned 1.7 µm diameter poly (ester-urethane urea) microfibers as substrates to examine their effect on hCSC viability, morphology, proliferation, and differentiation relative to cells cultured on tissue culture polystyrene (TCPS). The results showed that cells on microfiber meshes displayed an elongated morphology aligned in the direction of fiber orientation, lower proliferation rates, but increasedmore » expressions of genes and proteins majorly associated with cardiomyocyte phenotype. The early (NK2 homeobox 5, Nkx2.5) and late (cardiac troponin I, cTnI) cardiomyocyte genes were significantly increased on meshes (Nkx=2.5 56.2±13.0, cTnl=2.9±0.56,) over TCPS (Nkx2.5=4.2±0.9, cTnl=1.6±0.5, n=9, p<0.05 for both groups) after differentiation. In contrast, expressions of smooth muscle markers, Gata6 and myosin heavy chain (SM-MHC), were decreased on meshes. Immunocytochemical analysis with cardiac antibody exhibited the similar pattern of above cardiac differentiation. We conclude that aligned microfiber meshes are suitable for guiding cardiac differentiation of hCSCs and may facilitate stem cell-based therapies for treatment of cardiac diseases. - Highlights: • First study to characterize c-kit{sup +} human cardiac stem cells on microfiber meshes. • Microfiber meshes seem reducing cell proliferation, but no effect on cell viability. • Microfiber meshes facilitate the elongation of human cardiac stem cells in culture. • Cardiac but not smooth muscle differentiation were enhanced on microfiber meshes. • Microfiber meshes may be used as cardiac patches in cell-based cardiac therapy.« less
Nune, K C; Misra, R D K; Li, S J; Hao, Y L; Zhang, W
2016-10-01
The objective of the study is to fundamentally elucidate the biological response of 3D printed mesh structures subjected to plasma electrolytic oxidation process through the study of osteoblast functions. The cellular activity of plasma electrolytic-oxidized mesh structure was explored in terms of cell-to-cell communication involving proliferation, synthesis of extracellular and intracellular proteins, and mineralization. Upon plasma electrolytic oxidation of the mesh structure, a thin layer of bioactive titania with pore size 1-3 µm was nucleated on the surface. The combination of microporous bioactive titania and interconnected porous architecture provided the desired pathway for supply of nutrients and oxygen to cells and tissue and a favorable osteogenic microenvironment for tissue on-growth and in-growth, in relation to the unmodified mesh structure. The formation of a confluent layer as envisaged via electron microscopy and quantitative assessment of the expression level of proteins (actin, vinculin, and fibronectin) point toward the determining role of surface-modified mesh structure in modulating osteoblasts functions. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2488-2501, 2016. © 2016 Wiley Periodicals, Inc.
Beaulieu, A; Reebs, S G
2009-01-01
The present study investigated the effects of bedding material (pine shavings versus beta chip) and running wheel surfaces (standard metal bars versus metal bars covered with a plastic mesh) on the occurrence of wounds on the paws of male and female Syrian (golden) hamsters, Mesocricetus auratus. Four groups of 10 males and 10 females were each assigned to one of the following treatments: pine/no mesh, pine/mesh, chips/no mesh and chips/mesh. Each hamster paw was observed at 1-3-day intervals for 60 days. A total of 1-3 wounds, separate in time, developed on the paws (mostly the hind ones) of almost all animals. Wounds appeared as small pinpricks, cuts or scabs, mostly on the palms. Females ran 15% less than males, yet their front paws were more commonly affected and their wounds tended to last longer. Hamsters with plastic mesh inside their wheels took longer to develop wounds but once they appeared, the wounds were larger and lasted longer. Hamsters on pine shavings developed fewer wounds and had more wound-free days. Hamsters kept running at high levels and many wounds did not heal during the study, suggesting a need for veterinary intervention.
Three new models for evaluation of standard involute spur gear mesh stiffness
NASA Astrophysics Data System (ADS)
Liang, Xihui; Zhang, Hongsheng; Zuo, Ming J.; Qin, Yong
2018-02-01
Time-varying mesh stiffness is one of the main internal excitation sources of gear dynamics. Accurate evaluation of gear mesh stiffness is crucial for gear dynamic analysis. This study is devoted to developing new models for spur gear mesh stiffness evaluation. Three models are proposed. The proposed model 1 can give very accurate mesh stiffness result but the gear bore surface must be assumed to be rigid. Enlighted by the proposed model 1, our research discovers that the angular deflection pattern of the gear bore surface of a pair of meshing gears under a constant torque basically follows a cosine curve. Based on this finding, two other models are proposed. The proposed model 2 evaluates gear mesh stiffness by using angular deflections at different circumferential angles of an end surface circle of the gear bore. The proposed model 3 requires using only the angular deflection at an arbitrary circumferential angle of an end surface circle of the gear bore but this model can only be used for a gear with the same tooth profile among all teeth. The proposed models are accurate in gear mesh stiffness evaluation and easy to use. Finite element analysis is used to validate the accuracy of the proposed models.
Influence of local meshing size on stress intensity factor of orthopedic lag screw
NASA Astrophysics Data System (ADS)
Husain, M. N.; Daud, R.; Basaruddin, K. S.; Mat, F.; Bajuri, M. Y.; Arifin, A. K.
2017-09-01
Linear elastic fracture mechanics (LEFM) concept is generally used to study the influence of crack on the performance of structures. In order to study the LEFM concept on damaged structure, the usage of finite element analysis software is implemented to do the simulation of the structure. Mesh generation is one of the most crucial procedures in finite element method. For the structure that crack or damaged, it is very important to determine the accurate local meshing size at the crack tip of the crack itself in order to get the accurate value of stress intensity factor, KI. Pre crack will be introduced to the lag screw based on the von mises' stress result that had been performed in previous research. This paper shows the influence of local mesh arrangement on numerical value of the stress intensity factor, KI obtained by the displacement method. This study aims to simulate the effect of local meshing which is the singularity region on stress intensity factor, KI to the critical point of failure in screw. Five different set of wedges meshing size are introduced during the simulation of finite element analysis. The number of wedges used to simulate this research is 8, 10, 14, 16 and 20. There are three set of numerical equations used to validate the results which are brown and srawley, gross and brown and Tada equation. The result obtained from the finite element software (ANSYS APDL) has a positive agreement with the numerical analysis which is Brown and Srawley compared to other numerical formula. Radius of first row size of 0.014 and singularity element with 14 numbers of wedges is proved to be the best local meshing for this study.
Evaluation of the Antimicrobial Activity of Lysostaphin-Coated Hernia Repair Meshes▿
Satishkumar, Rohan; Sankar, Sriram; Yurko, Yuliya; Lincourt, Amy; Shipp, John; Heniford, B. Todd; Vertegel, Alexey
2011-01-01
Bacterial infections by antibiotic-resistant Staphylococcus aureus strains are among the most common postoperative complications in surgical hernia repair with synthetic mesh. Surface coating of medical devices/implants using antibacterial peptides and enzymes has recently emerged as a potentially effective method for preventing infections. The objective of this study was to evaluate the in vitro antimicrobial activity of hernia repair meshes coated by the antimicrobial enzyme lysostaphin at different initial concentrations. Lysostaphin was adsorbed on pieces of polypropylene (Ultrapro) mesh with binding yields of ∼10 to 40% at different coating concentrations of between 10 and 500 μg/ml. Leaching of enzyme from the surface of all the samples was studied in 2% (wt/vol) bovine serum albumin in phosphate-buffered saline buffer at 37°C, and it was found that less than 3% of adsorbed enzyme desorbed from the surface after 24 h of incubation. Studies of antibacterial activity against a cell suspension of S. aureus were performed using turbidity assay and demonstrated that the small amount of enzyme leaching from the mesh surface contributes to the lytic activity of the lysostaphin-coated samples. Colony counting data from the broth count (model for bacteria in wound fluid) and wash count (model for colonized bacteria) for the enzyme-coated samples showed significantly decreased numbers of CFU compared to uncoated samples (P < 0.05). A pilot in vivo study showed a dose-dependent efficacy of lysostaphin-coated meshes in a rat model of S. aureus infection. The antimicrobial activity of the lysostaphin-coated meshes suggests that such enzyme-leaching surfaces could be efficient at actively resisting initial bacterial adhesion and preventing subsequent colonization of hernia repair meshes. PMID:21709102
Steady state RANS simulations of temperature fluctuations in single phase turbulent mixing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kickhofel, J.; Fokken, J.; Kapulla, R.
2012-07-01
Single phase turbulent mixing in nuclear power plant circuits where a strong temperature gradient is present is known to precipitate pipe failure due to thermal fatigue. Experiments in a square mixing channel offer the opportunity to study the phenomenon under simple and easily reproducible boundary conditions. Measurements of this kind have been performed extensively at the Paul Scherrer Inst. in Switzerland with a high density of instrumentation in the Generic Mixing Experiment (GEMIX). As a fundamental mixing phenomena study closely related to the thermal fatigue problem, the experimental results from GEMIX are valuable for the validation of CFD codes strivingmore » to accurately simulate both the temperature and velocity fields in single phase turbulent mixing. In the experiments two iso-kinetic streams meet at a shallow angle of 3 degrees and mix in a straight channel of square cross-section under various degrees of density, temperature, and viscosity stratification over a range of Reynolds numbers ranging from 5*10{sup 3} to 1*10{sup 5}. Conductivity measurements, using wire-mesh and wall sensors, as well as optical measurements, using particle image velocimetry, were conducted with high temporal and spatial resolutions (up to 2.5 kHz and 1 mm in the case of the wire mesh sensor) in the mixing zone, downstream of a splitter plate. The present paper communicates the results of RANS modeling of selected GEMIX tests. Steady-state CFD calculations using a RANS turbulence model represent an inexpensive method for analyzing large and complex components in commercial nuclear reactors, such as the downcomer and reactor pressure vessel heads. Crucial to real world applicability, however, is the ability to model turbulent heat fluctuations in the flow; the Turbulent Heat Flux Transport model developed by ANSYS CFX is capable, by implementation of a transport equation for turbulent heat fluxes, of readily modeling these values. Furthermore, the closure of the turbulent heat flux transport equation evokes a transport equation for the variance of the enthalpy. It is therefore possible to compare the modeled fluctuations of the liquid temperature directly with the scalar fluctuations recorded experimentally with the wire-mesh. Combined with a working Turbulent Heat Flux Transport model, complex mixing problems in large geometries could be better understood. We aim for the validation of Reynolds Stress based RANS simulations extended by the Turbulent Heat Flux Transport model by modeling the GEMIX experiments in detail. Numerical modeling has been performed using both BSL and SSG Reynolds Stress Models in a test matrix comprising experimental trials at the GEMIX facility. We expand on the turbulent mixing RANS CFD results of (Manera 2009) in a few ways. In the GEMIX facility we introduce density stratification in the flow while removing the characteristic large scale vorticity encountered in T-junctions and therefore find better conditions to check the diffusive conditions in the model. Furthermore, we study the performance of the model in a very different, simpler scalar fluctuation spectrum. The paper discusses the performance of the model regarding the dissipation of the turbulent kinetic energy and dissipation of the enthalpy variance. A novel element is the analyses of cases with density stratification. (authors)« less
NASA Astrophysics Data System (ADS)
Chao, Tsi-Chian; Tsai, Yi-Chun; Chen, Shih-Kuan; Wu, Shu-Wei; Tung, Chuan-Jong; Hong, Ji-Hong; Wang, Chun-Chieh; Lee, Chung-Chi
2017-08-01
The purpose of this study was to investigate the density heterogeneity pattern as a factor affecting Bragg peak degradation, including shifts in Bragg peak depth (ZBP), distal range (R80 and R20), and distal fall-off (R80-R20) using Monte Carlo N-Particles, eXtension (MCNPX). Density heterogeneities of different patterns with increasing complexity were placed downstream of commissioned proton beams at the Proton and Radiation Therapy Centre of Chang Gung Memorial Hospital, including one 150 MeV wobbling broad beam (10×10 cm2) and one 150 MeV proton pencil beam (FWHM of cross-plane=2.449 cm, FWHM of in-plane=2.256 cm). MCNPX 2.7.0 was used to model the transport and interactions of protons and secondary particles in density heterogeneity patterns and water using its repeated structure geometry. Different heterogeneity patterns were inserted into a 21×21×20 cm3 phantom. Mesh tally was used to track the dose distribution when the proton beam passed through the different density heterogeneity patterns. The results show that different heterogeneity patterns do cause different Bragg peak degradations owing to multiple Coulomb scattering (MCS) occurring in the density heterogeneities. A trend of increasing R20 and R80-R20 with increasing geometry complexity was observed. This means that Bragg peak degradation is mainly caused by the changes to the proton spectrum owing to MCS in the density heterogeneities. In contrast, R80 did not change considerably with different heterogeneity patterns, which indicated that the energy spectrum has only minimum effects on R80. Bragg peak degradation can occur both for a broad proton beam and a pencil beam, but is less significant for the broad beam.
The Hot-Pressing of Hafnium Carbide (Melting Point, 7030 F)
NASA Technical Reports Server (NTRS)
Sanders, William A.; Grisaffe, Salvatore J.
1960-01-01
An investigation was undertaken to determine the effects of the hot-pressing variables (temperature, pressure, and time) on the density and grain size of hafnium carbide disks. The purpose was to provide information necessary for the production of high-density test shapes for the determination of physical and mechanical properties. Hot-pressing of -325 mesh hafnium carbide powder was accomplished with a hydraulic press and an inductively heated graphite die assembly. The ranges investigated for each variable were as follows: temperature, 3500 to 4870 F; pressure, 1000 to 6030 pounds per square inch; and time, 5 to 60 minutes. Hafnium carbide bodies of approximately 98 percent theoretical density can be produced under the following minimal conditions: 4230 F, 3500 pounds per square inch, and 15 minutes. Further increases in temperature and time resulted only in greater grain size.
NASA Astrophysics Data System (ADS)
Wismogroho, Agus Sukarto; Firmansyah, Trisna Bagus; Meidianto, Alwi; Widayatno, Wahyu Bambang; Amal, Muhamad Ikhlasul
2018-05-01
This paper reports the effect of aluminium corrosion reaction on the density, porosity, and thermal insulation capability of porous fire bricks. The reaction between aluminium and alkaline solution produces hydrogen and other sediment products. The test specimens of fire bricks were made from the mixture of castable cement, aluminium powder of 325 mesh in size (0, 0.1, 1, and 2 wt% with respect to castable cement), and 0.185 M KOH solution. The structural examination of the specimens shows the increase of porosity to 22.7 - 30.6% and the decrease of density in the range of 1.135-1.503 g/mL. In addition, the samples possess average pore size of 0.001-0.003 cm3 with the thermal insulation in the range of 47-78%.
Fluid intake from beverages across age groups: a systematic review.
Özen, A E; Bibiloni, M Del Mar; Pons, A; Tur, J A
2015-10-01
Fluid intake, especially water, is essential for human life and also necessary for physical and mental function. The present study aimed to assess beverage consumption across age groups. A systematic review was conducted. Original research in English language publications and available studies (or abstracts in English) from 2000 to 2013 was searched for by using the medical subheading (MeSH) terms: ('beverage' OR 'fluid' [Major]) AND ('consumption' [Mesh] OR 'drinking' [Mesh] OR 'intake' [Mesh]) AND ('child' [Mesh] OR 'adolescent' [Mesh] OR 'adult' [Mesh]). Article selection was restricted to those papers covering healthy populations of all age groups in a nationwide sample, or from a representative sample of the population of a city or cities, which examined the trends or patterns of beverage intake and the determinants of beverage intake. Sixty-five studies were identified with respect to beverage consumption across age groups. The papers were screened by thoroughly reading titles or abstracts. Full-text articles were assessed by three investigators. Total beverage intake varied between 0.6 and 3.5 L day(-1) among all age groups (males more than females). Plain water contributed up to 58%, 75% and 80% of the total beverage intake in children, adolescents and adults, respectively. Milk consumption was higher among children; consumption of soft drinks was higher among adolescents; and the consumption of tea, coffee and alcoholic beverages was higher among adults. Plain water is the main water source for all age groups and the consumption of other beverages varies according to age. © 2014 The British Dietetic Association Ltd.
Slattery, Stuart R.
2015-12-02
In this study we analyze and extend mesh-free algorithms for three-dimensional data transfer problems in partitioned multiphysics simulations. We first provide a direct comparison between a mesh-based weighted residual method using the common-refinement scheme and two mesh-free algorithms leveraging compactly supported radial basis functions: one using a spline interpolation and one using a moving least square reconstruction. Through the comparison we assess both the conservation and accuracy of the data transfer obtained from each of the methods. We do so for a varying set of geometries with and without curvature and sharp features and for functions with and without smoothnessmore » and with varying gradients. Our results show that the mesh-based and mesh-free algorithms are complementary with cases where each was demonstrated to perform better than the other. We then focus on the mesh-free methods by developing a set of algorithms to parallelize them based on sparse linear algebra techniques. This includes a discussion of fast parallel radius searching in point clouds and restructuring the interpolation algorithms to leverage data structures and linear algebra services designed for large distributed computing environments. The scalability of our new algorithms is demonstrated on a leadership class computing facility using a set of basic scaling studies. Finally, these scaling studies show that for problems with reasonable load balance, our new algorithms for both spline interpolation and moving least square reconstruction demonstrate both strong and weak scalability using more than 100,000 MPI processes with billions of degrees of freedom in the data transfer operation.« less
Simón-Allué, R; Ortillés, A; Calvo, B
2018-06-01
Despite the widespread use of synthetic meshes in the surgical treatment of the hernia pathology, the election criteria of a suitable mesh for specific patient continues to be uncertain. Thus, in this work, we propose a methodology to determine in advance potential disadvantages on the use of certain meshes based on the patient-specific abdominal geometry and the mechanical features of the certain meshes. To that purpose, we have first characterized the mechanical behavior of four synthetic meshes through biaxial tests. Secondly, two of these meshes were implanted in several New Zealand rabbits with a total defect previously created on the center of the abdominal wall. After the surgical procedure, specimen were subjected to in vivo pneumoperitoneum tests to determine the immediate post-surgical response of those meshes after implanted in a healthy specimen. Experimental performance was recorded by a stereo rig with the aim of obtaining quantitative information about the pressure-displacement relation of the abdominal wall. Finally, following the procedure presented in prior works (Simón-Allué et al., 2015, 2017), a finite element model was reconstructed from the experimental measurements and tests were computationally reproduced for the healthy and herniated cases. Simulations were compared and validated with the in vivo behavior and results were given along the abdominal wall in terms of displacements, stresses and strain. Mechanical characterization of the meshes revealed Surgipro TM as the most rigid implant and Neomesh SuperSoft® as the softer, while other two meshes (Neomesh Soft®, Neopore®) remained in between. These two meshes were employed in the experimental study and resulted in similar effect in the abdominal wall cavity and both were close to the healthy case. Simulations confirmed this result while showed potential objections in the case of the other two meshes, due to high values in stresses or elongation that may led to discomfort in real tissue. The use of this methodology on human surgery may provide the surgeons with reliable and useful information to avoid certain meshes on specific-patient treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wu, Jie; Li, Xin; Wu, Yang; Liao, Guoxing; Johnston, Priscilla; Topham, Paul D.; Wang, Linge
2017-11-01
An inherent problem that restricts the practical application of superhydrophobic materials is that the superhydrophobic property is not sustainable; it can be diminished, or even lost, when the surface is physically damaged. In this work, we present an efficient approach for the fabrication of superhydrophobic fibrous fabrics with great rinse-resistance where a block copolymer has been electrospun into a nanofibrous mesh while micro-sized beads have been subsequently electrosprayed to give a morphologically composite material. The intricate nano- and microstructure of the composite was then fixed by thermally annealing the block copolymer to induce self-assembly and interdigitation of the microphase separated domains. To demonstrate this approach, a polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene (SEBS) nanofibrous scaffold was produced by electrospinning before SEBS beads were electrosprayed into this mesh to form a hierarchical micro/nanostructure of beads and fibers. The effects of type and density of SEBS beads on the surface morphology and wetting properties of composite membranes were studied extensively. Compared with a neat SEBS fibrous mesh, the composite membrane had enhanced hydrophobic properties. The static water contact angle increased from 139° (±3°) to 156° (±1°), while the sliding angle decreased to 8° (±1°) from nearly 90°. In order to increase the rinse-resistance of the composite membrane, a thermal annealing step was applied to physically bind the fibers and beads. Importantly, after 200 h of water flushing, the hierarchical surface structure and superhydrophobicity of the composite membrane were well retained. This work provides a new route for the creation of superhydrophobic fabrics with potential in self-cleaning applications.
NASA Technical Reports Server (NTRS)
Woodard, Paul R.; Yang, Henry T. Y.; Batina, John T.
1992-01-01
Quality assessment procedures are described for two-dimensional and three-dimensional unstructured meshes. The procedures include measurement of minimum angles, element aspect ratios, stretching, and element skewness. Meshes about the ONERA M6 wing and the Boeing 747 transport configuration are generated using an advancing front method grid generation package of programs. Solutions of Euler's equations for these meshes are obtained at low angle-of-attack, transonic conditions. Results for these cases, obtained as part of a validation study demonstrate the accuracy of an implicit upwind Euler solution algorithm.
Design and fabrication of novel anode flow-field for commercial size solid oxide fuel cells
NASA Astrophysics Data System (ADS)
Canavar, Murat; Timurkutluk, Bora
2017-04-01
In this study, nickel based woven meshes are tested as not only anode current collecting meshes but also anode flow fields instead of the conventional gas channels fabricated by machining. For this purpose, short stacks with different anode flow fields are designed and built by using different number of meshes with various wire diameters and widths of opening. A short stack with classical machined flow channels is also constructed. Performance and impedance measurements of the short stacks with commercial size cells of 81 cm2 active area are performed and compared. The results reveal that it is possible to create solid oxide fuel cell anode flow fields with woven meshes and obtain acceptable power with a proper selection of the mesh number, type and orientation.
A voxel-based finite element model for the prediction of bladder deformation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chai Xiangfei; Herk, Marcel van; Hulshof, Maarten C. C. M.
2012-01-15
Purpose: A finite element (FE) bladder model was previously developed to predict bladder deformation caused by bladder filling change. However, two factors prevent a wide application of FE models: (1) the labor required to construct a FE model with high quality mesh and (2) long computation time needed to construct the FE model and solve the FE equations. In this work, we address these issues by constructing a low-resolution voxel-based FE bladder model directly from the binary segmentation images and compare the accuracy and computational efficiency of the voxel-based model used to simulate bladder deformation with those of a classicalmore » FE model with a tetrahedral mesh. Methods: For ten healthy volunteers, a series of MRI scans of the pelvic region was recorded at regular intervals of 10 min over 1 h. For this series of scans, the bladder volume gradually increased while rectal volume remained constant. All pelvic structures were defined from a reference image for each volunteer, including bladder wall, small bowel, prostate (male), uterus (female), rectum, pelvic bone, spine, and the rest of the body. Four separate FE models were constructed from these structures: one with a tetrahedral mesh (used in previous study), one with a uniform hexahedral mesh, one with a nonuniform hexahedral mesh, and one with a low-resolution nonuniform hexahedral mesh. Appropriate material properties were assigned to all structures and uniform pressure was applied to the inner bladder wall to simulate bladder deformation from urine inflow. Performance of the hexahedral meshes was evaluated against the performance of the standard tetrahedral mesh by comparing the accuracy of bladder shape prediction and computational efficiency. Results: FE model with a hexahedral mesh can be quickly and automatically constructed. No substantial differences were observed between the simulation results of the tetrahedral mesh and hexahedral meshes (<1% difference in mean dice similarity coefficient to manual contours and <0.02 cm difference in mean standard deviation of residual errors). The average equation solving time (without manual intervention) for the first two types of hexahedral meshes increased to 2.3 h and 2.6 h compared to the 1.1 h needed for the tetrahedral mesh, however, the low-resolution nonuniform hexahedral mesh dramatically decreased the equation solving time to 3 min without reducing accuracy. Conclusions: Voxel-based mesh generation allows fast, automatic, and robust creation of finite element bladder models directly from binary segmentation images without user intervention. Even the low-resolution voxel-based hexahedral mesh yields comparable accuracy in bladder shape prediction and more than 20 times faster in computational speed compared to the tetrahedral mesh. This approach makes it more feasible and accessible to apply FE method to model bladder deformation in adaptive radiotherapy.« less
NASA Technical Reports Server (NTRS)
Werner, Christopher R.; Mulugeta, Lealem; Myers, J. G.; Pennline, J. A.
2015-01-01
NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone in the absence of mechanical loading. The model was recently updated to include skeletal loading from exercise and free living activities to maintain healthy bone using a new daily load stimulus (DLS). This new formula was developed based on an extensive review of existing DLS formulas, as discussed in the abstract by Pennline et al. The DLS formula incorporated into the bone remodeling model utilizes strains and stress calculated from finite element model (FEM) of the bone region of interest. The proximal femur was selected for the initial application of the DLS formula, with a specific focus on the femoral neck. METHODS: The FEM was generated from CAD geometry of a femur using de-identified CT data. The femur was meshed using linear tetrahedral elements Figure (1) with higher mesh densities in the femoral neck region, which is the primary region of interest for the initial application of the DLS formula in concert with the DAP bone remodeling model. Nodal loads were applied to the femoral head and the greater trochanter and the base of the femur was held fixed. An L2 norm study was conducted to reduce the length of the femoral shaft without significantly impacting the stresses in the femoral neck. The material properties of the FEM of the proximal femur were separated between cortical and trabecular regions to work with the bone remodeling model. Determining the elements with cortical material properties in the FEM was based off of publicly available CT hip scans [4] that were segmented, cleaned, and overlaid onto the FEM.
DISCO: A 3D Moving-mesh Magnetohydrodynamics Code Designed for the Study of Astrophysical Disks
NASA Astrophysics Data System (ADS)
Duffell, Paul C.
2016-09-01
This work presents the publicly available moving-mesh magnetohydrodynamics (MHD) code DISCO. DISCO is efficient and accurate at evolving orbital fluid motion in two and three dimensions, especially at high Mach numbers. DISCO employs a moving-mesh approach utilizing a dynamic cylindrical mesh that can shear azimuthally to follow the orbital motion of the gas. The moving mesh removes diffusive advection errors and allows for longer time-steps than a static grid. MHD is implemented in DISCO using an HLLD Riemann solver and a novel constrained transport (CT) scheme that is compatible with the mesh motion. DISCO is tested against a wide variety of problems, which are designed to test its stability, accuracy, and scalability. In addition, several MHD tests are performed which demonstrate the accuracy and stability of the new CT approach, including two tests of the magneto-rotational instability, one testing the linear growth rate and the other following the instability into the fully turbulent regime.
Hot water-repellent and mechanically durable superhydrophobic mesh for oil/water separation.
Cao, Min; Luo, Xiaomin; Ren, Huijun; Feng, Jianyan
2018-02-15
The leakage of oil or organic pollutants into the ocean arouses a global catastrophe. The superhydrophobic materials have offered a new idea for the efficient, thorough and automated oil/water separation. However, most of such materials lose superhydrophobicity when exposed to hot water (e.g. >55 °C). In this study, a hot water-repellent superhydrophobic mesh used for oil/water separation was prepared with one-step spray of modified polyurethane and hydrophobic silica nanoparticles on the copper mesh. The as-prepared superhydrophobic mesh could be applied as the effective materials for the separation of oil/water mixture with a temperature up to 100 °C. In addition, the obtained mesh could selectively remove a wide range of organic solvents from water with high absorption capacity and good recyclability. Moreover, the as-prepared superhydrophobic mesh shows excellent mechanical durability, which makes it a promising material for practical oil/water separation. Copyright © 2017 Elsevier Inc. All rights reserved.
Medical Subject Headings (MeSH) for indexing and retrieving open-source healthcare data.
Marc, David T; Khairat, Saif S
2014-01-01
The US federal government initiated the Open Government Directive where federal agencies are required to publish high value datasets so that they are available to the public. Data.gov and the community site Healthdata.gov were initiated to disperse such datasets. However, data searches and retrieval for these sites are keyword driven and severely limited in performance. The purpose of this paper is to address the issue of extracting relevant open-source data by proposing a method of adopting the MeSH framework for indexing and data retrieval. A pilot study was conducted to compare the performance of traditional keywords to MeSH terms for retrieving relevant open-source datasets related to "mortality". The MeSH framework resulted in greater sensitivity with comparable specificity to the keyword search. MeSH showed promise as a method for indexing and retrieving data, yet future research should conduct a larger scale evaluation of the performance of the MeSH framework for retrieving relevant open-source healthcare datasets.
DISCO: A 3D MOVING-MESH MAGNETOHYDRODYNAMICS CODE DESIGNED FOR THE STUDY OF ASTROPHYSICAL DISKS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duffell, Paul C., E-mail: duffell@berkeley.edu
2016-09-01
This work presents the publicly available moving-mesh magnetohydrodynamics (MHD) code DISCO. DISCO is efficient and accurate at evolving orbital fluid motion in two and three dimensions, especially at high Mach numbers. DISCO employs a moving-mesh approach utilizing a dynamic cylindrical mesh that can shear azimuthally to follow the orbital motion of the gas. The moving mesh removes diffusive advection errors and allows for longer time-steps than a static grid. MHD is implemented in DISCO using an HLLD Riemann solver and a novel constrained transport (CT) scheme that is compatible with the mesh motion. DISCO is tested against a wide varietymore » of problems, which are designed to test its stability, accuracy, and scalability. In addition, several MHD tests are performed which demonstrate the accuracy and stability of the new CT approach, including two tests of the magneto-rotational instability, one testing the linear growth rate and the other following the instability into the fully turbulent regime.« less
Tangle-Free Finite Element Mesh Motion for Ablation Problems
NASA Technical Reports Server (NTRS)
Droba, Justin
2016-01-01
Mesh motion is the process by which a computational domain is updated in time to reflect physical changes in the material the domain represents. Such a technique is needed in the study of the thermal response of ablative materials, which erode when strong heating is applied to the boundary. Traditionally, the thermal solver is coupled with a linear elastic or biharmonic system whose sole purpose is to update mesh node locations in response to altering boundary heating. Simple mesh motion algorithms rely on boundary surface normals. In such schemes, evolution in time will eventually cause the mesh to intersect and "tangle" with itself, causing failure. Furthermore, such schemes are greatly limited in the problems geometries on which they will be successful. This paper presents a comprehensive and sophisticated scheme that tailors the directions of motion based on context. By choosing directions for each node smartly, the inevitable tangle can be completely avoided and mesh motion on complex geometries can be modeled accurately.
Graded meshes in bio-thermal problems with transmission-line modeling method.
Milan, Hugo F M; Carvalho, Carlos A T; Maia, Alex S C; Gebremedhin, Kifle G
2014-10-01
In this study, the transmission-line modeling (TLM) applied to bio-thermal problems was improved by incorporating several novel computational techniques, which include application of graded meshes which resulted in 9 times faster in computational time and uses only a fraction (16%) of the computational resources used by regular meshes in analyzing heat flow through heterogeneous media. Graded meshes, unlike regular meshes, allow heat sources to be modeled in all segments of the mesh. A new boundary condition that considers thermal properties and thus resulting in a more realistic modeling of complex problems is introduced. Also, a new way of calculating an error parameter is introduced. The calculated temperatures between nodes were compared against the results obtained from the literature and agreed within less than 1% difference. It is reasonable, therefore, to conclude that the improved TLM model described herein has great potential in heat transfer of biological systems. Copyright © 2014 Elsevier Ltd. All rights reserved.
Effects of Mesh Irregularities on Accuracy of Finite-Volume Discretization Schemes
NASA Technical Reports Server (NTRS)
Diskin, Boris; Thomas, James L.
2012-01-01
The effects of mesh irregularities on accuracy of unstructured node-centered finite-volume discretizations are considered. The focus is on an edge-based approach that uses unweighted least-squares gradient reconstruction with a quadratic fit. For inviscid fluxes, the discretization is nominally third order accurate on general triangular meshes. For viscous fluxes, the scheme is an average-least-squares formulation that is nominally second order accurate and contrasted with a common Green-Gauss discretization scheme. Gradient errors, truncation errors, and discretization errors are separately studied according to a previously introduced comprehensive methodology. The methodology considers three classes of grids: isotropic grids in a rectangular geometry, anisotropic grids typical of adapted grids, and anisotropic grids over a curved surface typical of advancing layer grids. The meshes within the classes range from regular to extremely irregular including meshes with random perturbation of nodes. Recommendations are made concerning the discretization schemes that are expected to be least sensitive to mesh irregularities in applications to turbulent flows in complex geometries.
NASA Astrophysics Data System (ADS)
Grayver, Alexander V.
2015-07-01
This paper presents a distributed magnetotelluric inversion scheme based on adaptive finite-element method (FEM). The key novel aspect of the introduced algorithm is the use of automatic mesh refinement techniques for both forward and inverse modelling. These techniques alleviate tedious and subjective procedure of choosing a suitable model parametrization. To avoid overparametrization, meshes for forward and inverse problems were decoupled. For calculation of accurate electromagnetic (EM) responses, automatic mesh refinement algorithm based on a goal-oriented error estimator has been adopted. For further efficiency gain, EM fields for each frequency were calculated using independent meshes in order to account for substantially different spatial behaviour of the fields over a wide range of frequencies. An automatic approach for efficient initial mesh design in inverse problems based on linearized model resolution matrix was developed. To make this algorithm suitable for large-scale problems, it was proposed to use a low-rank approximation of the linearized model resolution matrix. In order to fill a gap between initial and true model complexities and resolve emerging 3-D structures better, an algorithm for adaptive inverse mesh refinement was derived. Within this algorithm, spatial variations of the imaged parameter are calculated and mesh is refined in the neighborhoods of points with the largest variations. A series of numerical tests were performed to demonstrate the utility of the presented algorithms. Adaptive mesh refinement based on the model resolution estimates provides an efficient tool to derive initial meshes which account for arbitrary survey layouts, data types, frequency content and measurement uncertainties. Furthermore, the algorithm is capable to deliver meshes suitable to resolve features on multiple scales while keeping number of unknowns low. However, such meshes exhibit dependency on an initial model guess. Additionally, it is demonstrated that the adaptive mesh refinement can be particularly efficient in resolving complex shapes. The implemented inversion scheme was able to resolve a hemisphere object with sufficient resolution starting from a coarse discretization and refining mesh adaptively in a fully automatic process. The code is able to harness the computational power of modern distributed platforms and is shown to work with models consisting of millions of degrees of freedom. Significant computational savings were achieved by using locally refined decoupled meshes.
Herford, Alan Scott; Cicciù, Marco
2012-01-01
Purpose: The aim of this investigation was to evaluate whether the addition of the platelet derived growth factor type BB (PDGF-BB) to a collagen matrix applied on a titanium mesh would favor healing and resorption onto the grafted bone. A histologic and radiographic study of two different groups (test and control) was performed. Designs: A surgical procedure was performed on 8 pigs to obtain 16 bilateral mandibular alveolar defects. All the defects were then reconstructed with a mixture of autogenous bovine bone using titanium mesh positioning. Two groups, with a total of 16 defects were created: The first to study collagen sponge and PDGF-BB and the second to control collagen only. The collagen matrix was positioned directly over the mesh and soft tissue was closed without tensions onto both groups without attempting to obtain primary closure. Possible exposure of the titanium mesh as well as the height and volume of the new bone was recorded. Results: New bone formation averaged about 6.68 mm in the test group studied; the control group had less regenerated bone at 4.62 mm. Conclusion: PDGF-BB addition to the collagen matrix induced a strong increase in hard and soft tissue healing and favored bone formation, reducing bone resorption even if the mesh was exposed. PMID:23833493
Warthog: Coupling Status Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Shane W. D.; Reardon, Bradley T.
The Warthog code was developed to couple codes that are developed in both the Multi-Physics Object-Oriented Simulation Environment (MOOSE) from Idaho National Laboratory (INL) and SHARP from Argonne National Laboratory (ANL). The initial phase of this work, focused on coupling the neutronics code PROTEUS with the fuel performance code BISON. The main technical challenge involves mapping the power density solution determined by PROTEUS to the fuel in BISON. This presents a challenge since PROTEUS uses the MOAB mesh format, but BISON, like all other MOOSE codes, uses the libMesh format. When coupling the different codes, one must consider that Warthogmore » is a light-weight MOOSE-based program that uses the Data Transfer Kit (DTK) to transfer data between the various mesh types. Users set up inputs for the codes they want to run, and then Warthog transfers the data between them. Currently Warthog supports XSProc from SCALE or the Sub-Group Application Programming Interface (SGAPI) in PROTEUS for generating cross sections. It supports arbitrary geometries using PROTEUS and BISON. DTK will transfer power densities and temperatures between the codes where the domains overlap. In the past fiscal year (FY), much work has gone into demonstrating two-way coupling for simple pin cells of various materials. XSProc was used to calculate the cross sections, which were then passed to PROTEUS in an external file. PROTEUS calculates the fission/power density, and Warthog uses DTK to pass this information to BISON, where it is used as the heat source. BISON then calculates the temperature profile of the pin cell and sends it back to XSProc to obtain the temperature corrected cross sections. This process is repeated until the convergence criteria (tolerance on BISON solve, or number of time steps) is reached. Models have been constructed and run for both uranium oxide and uranium silicide fuels. These models demonstrate a clear difference in power shape that is not accounted for in a stand-alone BISON run. Future work involves improving the user interface (UI), likely through integration with the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Workbench. Furthermore, automating the input creation would ease the user experience. The next priority is to continue coupling the work with other codes in the SHARP package. Efforts on other projects include work to couple the Nek5000 thermo-hydraulics code to MOOSE, but this is in the preliminary stages.« less
NASA Astrophysics Data System (ADS)
Saye, Robert
2017-09-01
In this two-part paper, a high-order accurate implicit mesh discontinuous Galerkin (dG) framework is developed for fluid interface dynamics, facilitating precise computation of interfacial fluid flow in evolving geometries. The framework uses implicitly defined meshes-wherein a reference quadtree or octree grid is combined with an implicit representation of evolving interfaces and moving domain boundaries-and allows physically prescribed interfacial jump conditions to be imposed or captured with high-order accuracy. Part one discusses the design of the framework, including: (i) high-order quadrature for implicitly defined elements and faces; (ii) high-order accurate discretisation of scalar and vector-valued elliptic partial differential equations with interfacial jumps in ellipticity coefficient, leading to optimal-order accuracy in the maximum norm and discrete linear systems that are symmetric positive (semi)definite; (iii) the design of incompressible fluid flow projection operators, which except for the influence of small penalty parameters, are discretely idempotent; and (iv) the design of geometric multigrid methods for elliptic interface problems on implicitly defined meshes and their use as preconditioners for the conjugate gradient method. Also discussed is a variety of aspects relating to moving interfaces, including: (v) dG discretisations of the level set method on implicitly defined meshes; (vi) transferring state between evolving implicit meshes; (vii) preserving mesh topology to accurately compute temporal derivatives; (viii) high-order accurate reinitialisation of level set functions; and (ix) the integration of adaptive mesh refinement. In part two, several applications of the implicit mesh dG framework in two and three dimensions are presented, including examples of single phase flow in nontrivial geometry, surface tension-driven two phase flow with phase-dependent fluid density and viscosity, rigid body fluid-structure interaction, and free surface flow. A class of techniques known as interfacial gauge methods is adopted to solve the corresponding incompressible Navier-Stokes equations, which, compared to archetypical projection methods, have a weaker coupling between fluid velocity, pressure, and interface position, and allow high-order accurate numerical methods to be developed more easily. Convergence analyses conducted throughout the work demonstrate high-order accuracy in the maximum norm for all of the applications considered; for example, fourth-order spatial accuracy in fluid velocity, pressure, and interface location is demonstrated for surface tension-driven two phase flow in 2D and 3D. Specific application examples include: vortex shedding in nontrivial geometry, capillary wave dynamics revealing fine-scale flow features, falling rigid bodies tumbling in unsteady flow, and free surface flow over a submersed obstacle, as well as high Reynolds number soap bubble oscillation dynamics and vortex shedding induced by a type of Plateau-Rayleigh instability in water ripple free surface flow. These last two examples compare numerical results with experimental data and serve as an additional means of validation; they also reveal physical phenomena not visible in the experiments, highlight how small-scale interfacial features develop and affect macroscopic dynamics, and demonstrate the wide range of spatial scales often at play in interfacial fluid flow.
NASA Astrophysics Data System (ADS)
Saye, Robert
2017-09-01
In this two-part paper, a high-order accurate implicit mesh discontinuous Galerkin (dG) framework is developed for fluid interface dynamics, facilitating precise computation of interfacial fluid flow in evolving geometries. The framework uses implicitly defined meshes-wherein a reference quadtree or octree grid is combined with an implicit representation of evolving interfaces and moving domain boundaries-and allows physically prescribed interfacial jump conditions to be imposed or captured with high-order accuracy. Part one discusses the design of the framework, including: (i) high-order quadrature for implicitly defined elements and faces; (ii) high-order accurate discretisation of scalar and vector-valued elliptic partial differential equations with interfacial jumps in ellipticity coefficient, leading to optimal-order accuracy in the maximum norm and discrete linear systems that are symmetric positive (semi)definite; (iii) the design of incompressible fluid flow projection operators, which except for the influence of small penalty parameters, are discretely idempotent; and (iv) the design of geometric multigrid methods for elliptic interface problems on implicitly defined meshes and their use as preconditioners for the conjugate gradient method. Also discussed is a variety of aspects relating to moving interfaces, including: (v) dG discretisations of the level set method on implicitly defined meshes; (vi) transferring state between evolving implicit meshes; (vii) preserving mesh topology to accurately compute temporal derivatives; (viii) high-order accurate reinitialisation of level set functions; and (ix) the integration of adaptive mesh refinement. In part two, several applications of the implicit mesh dG framework in two and three dimensions are presented, including examples of single phase flow in nontrivial geometry, surface tension-driven two phase flow with phase-dependent fluid density and viscosity, rigid body fluid-structure interaction, and free surface flow. A class of techniques known as interfacial gauge methods is adopted to solve the corresponding incompressible Navier-Stokes equations, which, compared to archetypical projection methods, have a weaker coupling between fluid velocity, pressure, and interface position, and allow high-order accurate numerical methods to be developed more easily. Convergence analyses conducted throughout the work demonstrate high-order accuracy in the maximum norm for all of the applications considered; for example, fourth-order spatial accuracy in fluid velocity, pressure, and interface location is demonstrated for surface tension-driven two phase flow in 2D and 3D. Specific application examples include: vortex shedding in nontrivial geometry, capillary wave dynamics revealing fine-scale flow features, falling rigid bodies tumbling in unsteady flow, and free surface flow over a submersed obstacle, as well as high Reynolds number soap bubble oscillation dynamics and vortex shedding induced by a type of Plateau-Rayleigh instability in water ripple free surface flow. These last two examples compare numerical results with experimental data and serve as an additional means of validation; they also reveal physical phenomena not visible in the experiments, highlight how small-scale interfacial features develop and affect macroscopic dynamics, and demonstrate the wide range of spatial scales often at play in interfacial fluid flow.
Jałyński, Marek; Piskorz, Łukasz; Brocki, Marian
2013-01-01
Introduction Formation of adhesions after laparoscopic hernia repair using the intra-peritoneal onlay mesh (IPOM) procedure can lead to intestinal obstruction or mesh erosion into intestinal lumen. The aims of this study included: measurement of adhesion formation with Dynamesh IPOM after laparoscopic intraperitoneal implantation, and assessment of the occurrence of isolated adhesions at the fastening sites of slowly absorbable sutures. Material and methods Twelve healthy pigs underwent laparoscopic implantation of 2 Dynamesh IPOM mesh fragments each, one was fastened with PDSII, and the other with Maxon sutures. An assessment of adhesion formation was carried out after 6 weeks and included an evaluation of surface area, hardness according to the Zhulke scale, and index values. The occurrence of isolated adhesions at slowly absorbable suture fixation points was also analyzed. Results Adhesions were noted in 83.3% of Dynamesh IPOM meshes. Adhesions covered on average 37.7% of the mesh surface with mean hardness 1.46 and index value 78.8. In groups fixed with PDS in comparison to Maxon sutures adhesions covered mean 31.6% vs. 42.5% (p = 0.62) of the mesh surface, mean hardness was 1.67 vs.1.25 (p = 0.34) and index 85.42 vs. 72.02 (p = 0.95). Conclusions The Dynamesh IPOM mesh, in spite of its anti-adhesive layer of PVDF, does not prevent the formation of adhesions. Adhesion hardness, surface area, and index values of the Dynamesh IPOM mesh are close to the mean values of these parameters for other commercially available 2-layer meshes. Slowly absorbable sutures used for fastening did not increase the risk of adhesion formation. PMID:23847671
Miklos, John R; Chinthakanan, Orawee; Moore, Robert D; Mitchell, Gretchen K; Favors, Sheena; Karp, Deborah R; Northington, Gina M; Nogueiras, Gladys M; Davila, G Willy
2016-06-01
The objective was to report patterns of sling and transvaginal mesh-related complications using the IUGA/ICS classification of prosthesis-related complications. This was a retrospective chart review of all patients who underwent surgical removal of sling, transvaginal mesh, and sacrocolpopexy for mesh-related complications from 2011 to 2013 at three tertiary referral centers. The International Urogynecological Association (IUGA)/International Continence Society (ICS) classification system was utilized. We identified 445 patients with mesh complications, 506 pieces of synthetic mesh were removed, and 587 prostheses-related complications were classified. 3.7 % of patients had viscus organ penetration or vaginal exposure as their presenting chief complaint and 59.7 % were classified as not having any vaginal epithelial separation or category 1. The most common category was spontaneous pain (1Be: 32.5 %) followed by dyspareunia (1Bc: 14.7 %). The sling group was 20 % more likely to have pain compared with the pelvic organ prolapse (POP) mesh group (OR 1.2, 95 % CI 0.8-1.6). The most commonly affected site (S2) was away from the suture line (49 %). Compared with the sling group, the POP group had a higher rate of mesh exposure, which mostly occurred at the suture line area. The majority of patients presented with mesh-related complications more than 1 year post-insertion (T4; average 3.68 ± 2.47 years). Surgeons should be aware that patients with vaginal mesh complications routinely exhibit complications more than 1 year after the implantation with pain as the most common presenting symptom.
Challenging the Myth: Transvaginal Mesh is Not Associated with Carcinogenesis.
Chughtai, Bilal; Sedrakyan, Art; Mao, Jialin; Thomas, Dominique; Eilber, Karyn S; Clemens, J Quentin; Anger, Jennifer T
2017-10-01
We sought to determine if there was a potential link between synthetic polypropylene mesh implantation for transvaginal pelvic organ prolapse and stress urinary incontinence, and carcinogenesis using statewide administrative data. Women who underwent transvaginal surgery for pelvic organ prolapse or stress urinary incontinence with mesh between January 2008 and December 2009 in New York State were identified using ICD-9-CM procedure codes and CPT-4 codes. Patients in the mesh cohort were individually matched to 2 control cohorts based on comorbidities and procedure date. Carcinogenesis was determined before and after matching at 1, 2 and 3 years, and during the entire followup time. A total of 2,229 patients who underwent mesh based pelvic organ prolapse surgery and 10,401 who underwent sling surgery for stress urinary incontinence between January 2008 and December 2009 were included in the study. Mean followup was 6 years (range 5 to 7). Exact matching between the mesh and control cohorts resulted in 1,870 pairs for pelvic organ prolapse mesh and cholecystectomy (1:2), 1,278 pairs for pelvic organ prolapse mesh and hysterectomy (1:1), 7,986 pairs for sling and cholecystectomy (1:1) and 3,810 pairs for sling and hysterectomy (1:1). Transvaginal mesh implantation was not associated with an increased risk of a cancer diagnosis (pelvic/local cancers or any cancer) at 1 year and during the entire followup of up to 7 years. Transvaginal surgery with implantation of mesh was not associated with the development of malignancy at a mean followup of 6 years. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Pascual, Gemma; Hernández-Gascón, Belén; Rodríguez, Marta; Sotomayor, Sandra; Peña, Estefania; Calvo, Begoña; Bellón, Juan M
2012-11-01
Although heavyweight (HW) or lightweight (LW) polypropylene (PP) meshes are widely used for hernia repair, other alternatives have recently appeared. They have the same large-pore structure yet are composed of polytetrafluoroethylene (PTFE). This study compares the long-term (3 and 6 months) behavior of meshes of different pore size (HW compared with LW) and composition (PP compared with PTFE). Partial defects were created in the lateral wall of the abdomen in New Zealand White rabbits and then repaired by the use of a HW or LW PP mesh or a new monofilament, large-pore PTFE mesh (Infinit). At 90 and 180 days after implantation, tissue incorporation, gene and protein expression of neocollagens (reverse transcription-polymerase chain reaction/immunofluorescence), macrophage response (immunohistochemistry), and biomechanical strength were determined. Shrinkage was measured at 90 days. All three meshes induced good host tissue ingrowth, yet the macrophage response was significantly greater in the PTFE implants (P < .05). Collagen 1/3 mRNA levels failed to vary at 90 days yet in the longer term, the LW meshes showed the reduced genetic expression of both collagens (P < .05) accompanied by increased neocollagen deposition, indicating more efficient mRNA translation. After 90-180 days of implant, tensile strengths and elastic modulus values were similar for all 3 implants (P > .05). Host collagen deposition is mesh pore size dependent whereas the macrophage response induced is composition dependent with a greater response shown by PTFE. In the long term, macroporous meshes show comparable biomechanical behavior regardless of their pore size or composition. Copyright © 2012 Mosby, Inc. All rights reserved.
A software platform for continuum modeling of ion channels based on unstructured mesh
NASA Astrophysics Data System (ADS)
Tu, B.; Bai, S. Y.; Chen, M. X.; Xie, Y.; Zhang, L. B.; Lu, B. Z.
2014-01-01
Most traditional continuum molecular modeling adopted finite difference or finite volume methods which were based on a structured mesh (grid). Unstructured meshes were only occasionally used, but an increased number of applications emerge in molecular simulations. To facilitate the continuum modeling of biomolecular systems based on unstructured meshes, we are developing a software platform with tools which are particularly beneficial to those approaches. This work describes the software system specifically for the simulation of a typical, complex molecular procedure: ion transport through a three-dimensional channel system that consists of a protein and a membrane. The platform contains three parts: a meshing tool chain for ion channel systems, a parallel finite element solver for the Poisson-Nernst-Planck equations describing the electrodiffusion process of ion transport, and a visualization program for continuum molecular modeling. The meshing tool chain in the platform, which consists of a set of mesh generation tools, is able to generate high-quality surface and volume meshes for ion channel systems. The parallel finite element solver in our platform is based on the parallel adaptive finite element package PHG which wass developed by one of the authors [1]. As a featured component of the platform, a new visualization program, VCMM, has specifically been developed for continuum molecular modeling with an emphasis on providing useful facilities for unstructured mesh-based methods and for their output analysis and visualization. VCMM provides a graphic user interface and consists of three modules: a molecular module, a meshing module and a numerical module. A demonstration of the platform is provided with a study of two real proteins, the connexin 26 and hemolysin ion channels.
A comparative study on different methods of automatic mesh generation of human femurs.
Viceconti, M; Bellingeri, L; Cristofolini, L; Toni, A
1998-01-01
The aim of this study was to evaluate comparatively five methods for automating mesh generation (AMG) when used to mesh a human femur. The five AMG methods considered were: mapped mesh, which provides hexahedral elements through a direct mapping of the element onto the geometry; tetra mesh, which generates tetrahedral elements from a solid model of the object geometry; voxel mesh which builds cubic 8-node elements directly from CT images; and hexa mesh that automatically generated hexahedral elements from a surface definition of the femur geometry. The various methods were tested against two reference models: a simplified geometric model and a proximal femur model. The first model was useful to assess the inherent accuracy of the meshes created by the AMG methods, since an analytical solution was available for the elastic problem of the simplified geometric model. The femur model was used to test the AMG methods in a more realistic condition. The femoral geometry was derived from a reference model (the "standardized femur") and the finite element analyses predictions were compared to experimental measurements. All methods were evaluated in terms of human and computer effort needed to carry out the complete analysis, and in terms of accuracy. The comparison demonstrated that each tested method deserves attention and may be the best for specific situations. The mapped AMG method requires a significant human effort but is very accurate and it allows a tight control of the mesh structure. The tetra AMG method requires a solid model of the object to be analysed but is widely available and accurate. The hexa AMG method requires a significant computer effort but can also be used on polygonal models and is very accurate. The voxel AMG method requires a huge number of elements to reach an accuracy comparable to that of the other methods, but it does not require any pre-processing of the CT dataset to extract the geometry and in some cases may be the only viable solution.
Giordano, Salvatore; Garvey, Patrick B; Baumann, Donald P; Liu, Jun; Butler, Charles E
2017-02-01
Previous studies suggest that bridged mesh repair for abdominal wall reconstruction may result in worse outcomes than mesh-reinforced, primary fascial closure, particularly when acellular dermal matrix is used. We compared our outcomes of bridged versus reinforced repair using ADM in abdominal wall reconstruction procedures. This retrospective study included 535 consecutive patients at our cancer center who underwent abdominal wall reconstruction either for an incisional hernia or for abdominal wall defects left after excision of malignancies involving the abdominal wall with underlay mesh. A total of 484 (90%) patients underwent mesh-reinforced abdominal wall reconstruction and 51 (10%) underwent bridged repair abdominal wall reconstruction. Acellular dermal matrix was used, respectively, in 98% of bridged and 96% of reinforced repairs. We compared outcomes between these 2 groups using propensity score analysis for risk-adjustment in multivariate analysis and for 1-to-1 matching. Bridged repairs had a greater hernia recurrence rate (33.3% vs 6.2%, P < .001), a greater overall complication rate (59% vs 30%, P = .001), and worse freedom from hernia recurrence (log-rank P <.001) than reinforced repairs. Bridged repairs also had a greater rate of wound dehiscence (26% vs 14%, P = .034) and mesh exposure (10% vs 1%, P = .003) than mesh-reinforced abdominal wall reconstruction. When the treatment method was adjusted for propensity score in the propensity-score-matched pairs (n = 100), we found that the rates of hernia recurrence (32% vs 6%, P = .002), overall complications (32% vs 6%, P = .002), and freedom from hernia recurrence (68% vs 32%, P = .001) rates were worse after bridged repair. We did not observe differences in wound healing and mesh complications between the 2 groups. In our population of primarily cancer patients at MD Anderson Cancer Center bridged repair for abdominal wall reconstruction is associated with worse outcomes than mesh-reinforced abdominal wall reconstruction. Particularly when employing acellular dermal matrix, reinforced repairs should be used for abdominal wall reconstruction whenever possible. Copyright © 2016 Elsevier Inc. All rights reserved.
Polycaprolactone electrospun mesh conjugated with an MSC affinity peptide for MSC homing in vivo.
Shao, Zhenxing; Zhang, Xin; Pi, Yanbin; Wang, Xiaokun; Jia, Zhuqing; Zhu, Jingxian; Dai, Linghui; Chen, Wenqing; Yin, Ling; Chen, Haifeng; Zhou, Chunyan; Ao, Yingfang
2012-04-01
Mesenchymal stem cell (MSC) is a promising cell source candidate in tissue engineering (TE) and regenerative medicine. However, the inability to target MSCs in tissues of interest with high efficiency and engraftment has become a significant barrier for MSC-based therapies. The mobilization and transfer of MSCs to defective/damaged sites in tissues or organs in vivo with high efficacy and efficiency has been a major concern. In the present study, we identified a peptide sequence (E7) with seven amino acids through phage display technology, which has a high specific affinity to bone marrow-derived MSCs. Subsequent analysis suggested that the peptide could efficiently interact specifically with MSCs without any species specificity. Thereafter, E7 was covalently conjugated onto polycaprolactone (PCL) electrospun meshes to construct an "MSC-homing device" for the recruitment of MSCs both in vitro and in vivo. The E7-conjugated PCL electrospun meshes were implanted into a cartilage defect site of rat knee joints, combined with a microfracture procedure to mobilize the endogenous MSCs. After 7 d of implantation, immunofluorescence staining showed that the cells grown into the E7-conjugated PCL electrospun meshes yielded a high positive rate for specific MSC surface markers (CD44, CD90, and CD105) compared with those in arginine-glycine-aspartic acid (RGD)-conjugated PCL electrospun meshes (63.67% vs. 3.03%; 59.37% vs. 2.98%; and 61.45% vs. 3.82%, respectively). Furthermore, the percentage of CD68 positive cells in the E7-conjugated PCL electrospun meshes was much lower than that in the RGD-conjugated PCL electrospun meshes (5.57% vs. 53.43%). This result indicates that E7-conjugated PCL electrospun meshes absorb much less inflammatory cells in vivo than RGD-conjugated PCL electrospun meshes. The results of the present study suggest that the identified E7 peptide sequence has a high specific affinity to MSCs. Covalently conjugating this peptide on the synthetic PCL mesh significantly enhanced the MSC recruitment of PCL in vivo. This method provides a wide range of potential applications in TE. Copyright © 2012 Elsevier Ltd. All rights reserved.
Method and system for mesh network embedded devices
NASA Technical Reports Server (NTRS)
Wang, Ray (Inventor)
2009-01-01
A method and system for managing mesh network devices. A mesh network device with integrated features creates an N-way mesh network with a full mesh network topology or a partial mesh network topology.
Choi, Judy M; Nguyen, Vian; Khavari, Rose; Reeves, Keith; Snyder, Michael; Fletcher, Sophie G
2012-01-01
The use of synthetic mesh for transvaginal pelvic organ prolapse (POP) repair is associated with the rare complication of mesh erosion into hollow viscera. This study presents a single-institution series of complex rectovaginal fistulas (RVFs) after synthetic mesh-augmented POP repair, as well as strategies for identification and management. Institutional review board approval was obtained for this retrospective study. Data were collected and analyzed on all female patients undergoing RVF repair from 2000 to 2011 at our institution. Thirty-seven patients underwent RVF repair at our multidisciplinary center for restorative pelvic medicine. Of these, 10 (27.0%) were associated with POP repairs using mesh. The POP repairs resulting in RVF were transvaginal repair with mesh (n = 8), laparoscopic sacrocolpopexy with concomitant traditional posterior repair (n = 1), and robotic-assisted laparoscopic sacrocolpopexy (n = 1). Time to presentation was an average of 7.1 months after POP repair. Patients underwent a mean of 4.4 surgeries for definitive RVF repair, with 40% of patients requiring a bowel diversion (3 temporary ileostomies and 1 long-term colostomy). Mean follow-up time after last surgery was 9.2 months. On follow-up, 1 patient has a persistent fistula with vaginal mesh extrusion. One patient has persistent pelvic pain. This series highlights the significant impact of synthetic mesh complications in the posterior compartment. These complications should be cautionary for synthetic graft use by those with limited experience, particularly when an alternate choice of traditional repair is available. When symptoms of RVF are present, collaboration with a colon and rectal specialist should be initiated as soon as possible for evaluation and definitive repair.
Research Trend Visualization by MeSH Terms from PubMed.
Yang, Heyoung; Lee, Hyuck Jai
2018-05-30
Motivation : PubMed is a primary source of biomedical information comprising search tool function and the biomedical literature from MEDLINE which is the US National Library of Medicine premier bibliographic database, life science journals and online books. Complimentary tools to PubMed have been developed to help the users search for literature and acquire knowledge. However, these tools are insufficient to overcome the difficulties of the users due to the proliferation of biomedical literature. A new method is needed for searching the knowledge in biomedical field. Methods : A new method is proposed in this study for visualizing the recent research trends based on the retrieved documents corresponding to a search query given by the user. The Medical Subject Headings (MeSH) are used as the primary analytical element. MeSH terms are extracted from the literature and the correlations between them are calculated. A MeSH network, called MeSH Net, is generated as the final result based on the Pathfinder Network algorithm. Results : A case study for the verification of proposed method was carried out on a research area defined by the search query (immunotherapy and cancer and "tumor microenvironment"). The MeSH Net generated by the method is in good agreement with the actual research activities in the research area (immunotherapy). Conclusion : A prototype application generating MeSH Net was developed. The application, which could be used as a "guide map for travelers", allows the users to quickly and easily acquire the knowledge of research trends. Combination of PubMed and MeSH Net is expected to be an effective complementary system for the researchers in biomedical field experiencing difficulties with search and information analysis.
Investigation into the optimal prosthetic material for wound healing of abdominal wall defects
Akcakaya, Adem; Aydogdu, Ibrahim; Citgez, Bulent
2018-01-01
The purpose of this experimental study is to investigate and compare the effects of prosthetic materials used for wound healing of abdominal wall hernias. A total of 60 rats were divided into five equal groups: Group I, control subjected to laparotomy; group II, abdominal wall defect 3×2 cm+polypropylene (PP) mesh; group III, abdominal wall defect 3×2 cm+PP mesh+hyaluronate and carboxymethylcellulose (H-CMC; Seprafilm®); group IV, abdominal wall defect 3×2 cm+polytetrafluoroethylene (PTFE; Composix™); and group V, abdominal wall defect 3×2 cm+polyethylene terephthalate (PET; Dacron®). A total of 14 days after the surgery, rats were sacrificed and the meshes with the surrounding tissue were extracted in block. The breaking strength of the mesh from the fascia was recorded. The healing tissue was examined with the index of histopathology and the hydroxyproline value was analyzed using the Switzer method. Both the breaking strength and histopathological index of the wound healing were significantly improved in groups II and III compared with that in groups IV and V (P<0.001). Hydroxyproline values were the highest in group I (P<0.001). There was also a statistically significant difference between groups II and IV, and group V and the other groups (P<0.001). The present findings demonstrated that PP mesh and PP mesh+H-CMC had a superior breaking strength and improved histopathologic indices compared with PTFE and PET. Furthermore, hydroxyproline values were the lowest in the PET group. In conclusion, wound healing was improved in the PP mesh group and the PP mesh+H-CMC group compared with the PTFE and PET groups according to the present study parameters. PMID:29399133
NASA Technical Reports Server (NTRS)
Stapleton, Scott; Gries, Thomas; Waas, Anthony M.; Pineda, Evan J.
2014-01-01
Enhanced finite elements are elements with an embedded analytical solution that can capture detailed local fields, enabling more efficient, mesh independent finite element analysis. The shape functions are determined based on the analytical model rather than prescribed. This method was applied to adhesively bonded joints to model joint behavior with one element through the thickness. This study demonstrates two methods of maintaining the fidelity of such elements during adhesive non-linearity and cracking without increasing the mesh needed for an accurate solution. The first method uses adaptive shape functions, where the shape functions are recalculated at each load step based on the softening of the adhesive. The second method is internal mesh adaption, where cracking of the adhesive within an element is captured by further discretizing the element internally to represent the partially cracked geometry. By keeping mesh adaptations within an element, a finer mesh can be used during the analysis without affecting the global finite element model mesh. Examples are shown which highlight when each method is most effective in reducing the number of elements needed to capture adhesive nonlinearity and cracking. These methods are validated against analogous finite element models utilizing cohesive zone elements.
Lukban, James C.; Beyer, Roger D.; Moore, Robert D.
2012-01-01
Introduction and Hypothesis. We sought to determine the mesh extrusion (vaginal exposure) rates and subject outcomes following IntePro (Type I polypropylene) mesh “kit” repairs for vaginal prolapse. Methods. Data were pooled from two prospective multicenter studies evaluating the safety and efficacy of the Perigee and Apogee (American Medical Systems, Minnetonka, Minn, USA) to treat anterior and posterior/apical prolapses, respectively. Extrusions involving the anterior compartment (AC) or posterior compartment/apex (PC/A) were recorded. Results. Two hundred sixty women underwent mesh placement, with a total of 368 mesh units inserted (173 in the AC and 195 in the PC/A). Extrusions were noted in 13 (7.5%) of AC implants and 27 (13.8%) of PC/A implants through 12 months. No difference was seen between those with and without extrusion in regard to anatomic cure, postoperative painor quality of life at 1 year. Conclusions. Extrusion had no apparent effect on short-term outcomes. Given the unknown long-term sequellae of vaginal mesh exposure, a thorough assessment of risks and benefits of transvaginal mesh placement should be considered at the time of preoperative planning. PMID:22190952
AXAF VETA-I mirror encircled energy measurements and data reduction
NASA Technical Reports Server (NTRS)
Zhao, Ping; Freeman, Mark D.; Hughes, John P.; Kellogg, Edwin M.; Nguyen, Dan T.; Joy, Marshall; Kolodziejczak, Jeffery J.
1992-01-01
The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.
Prostheses size dependency of the mechanical response of the herniated human abdomen.
Simón-Allué, R; Hernández-Gascón, B; Lèoty, L; Bellón, J M; Peña, E; Calvo, B
2016-12-01
Hernia repairs still exhibit clinical complications, i.e. recurrence, discomfort and pain and mesh features are thought to be highly influent. The aim of this study is to evaluate the impact of the defect size and mesh type in an herniated abdominal wall using numerical models. To do so, we have started from a FE model based on a real human abdomen geometry obtained by MRI, where we have provoked an incisional hernia of three different sizes. The surgical procedure was simulated by covering the hernia with a prostheses, and three surgical meshes with distinct mechanical properties were used for the hernia repair: an isotropic heavy-weight mesh (Surgipro @ ), a slightly anisotropic light-weight mesh (Optilene @ ) and a highly anisotropic medium-weight mesh (Infinit @ ). The mechanical response of the wall to a high intraabdominal pressure (corresponding to a coughing motion) was analyzed here. Our findings suggest that the anisotropy of the mesh becomes more relevant with the increase of the defect size. Additionally, according to our results Optilene @ showed the closest deformation to the natural distensibility of the abdomen while Infinit @ should be carefully used due to its excessive compliance.
Optimization-based mesh correction with volume and convexity constraints
D'Elia, Marta; Ridzal, Denis; Peterson, Kara J.; ...
2016-02-24
In this study, we consider the problem of finding a mesh such that 1) it is the closest, with respect to a suitable metric, to a given source mesh having the same connectivity, and 2) the volumes of its cells match a set of prescribed positive values that are not necessarily equal to the cell volumes in the source mesh. This volume correction problem arises in important simulation contexts, such as satisfying a discrete geometric conservation law and solving transport equations by incremental remapping or similar semi-Lagrangian transport schemes. In this paper we formulate volume correction as a constrained optimizationmore » problem in which the distance to the source mesh defines an optimization objective, while the prescribed cell volumes, mesh validity and/or cell convexity specify the constraints. We solve this problem numerically using a sequential quadratic programming (SQP) method whose performance scales with the mesh size. To achieve scalable performance we develop a specialized multigrid-based preconditioner for optimality systems that arise in the application of the SQP method to the volume correction problem. Numerical examples illustrate the importance of volume correction, and showcase the accuracy, robustness and scalability of our approach.« less
Rosen, Michael J.; Bauer, Joel J.; Harmaty, Marco; Carbonell, Alfredo M.; Cobb, William S.; Matthews, Brent; Goldblatt, Matthew I.; Selzer, Don J.; Poulose, Benjamin K.; Hansson, Bibi M. E.; Rosman, Camiel; Chao, James J.; Jacobsen, Garth R.
2017-01-01
Objective: The aim of the study was to evaluate biosynthetic absorbable mesh in single-staged contaminated (Centers for Disease Control class II and III) ventral hernia (CVH) repair over 24 months. Background: CVH has an increased risk of postoperative infection. CVH repair with synthetic or biologic meshes has reported chronic biomaterial infections and high hernia recurrence rates. Methods: Patients with a contaminated or clean-contaminated operative field and a hernia defect at least 9 cm2 had a biosynthetic mesh (open, sublay, retrorectus, or intraperitoneal) repair with fascial closure (n = 104). Endpoints included overall Kaplan-Meier estimates for hernia recurrence and postoperative wound infection rates at 24 months, and the EQ-5D and Short Form 12 Health Survey (SF-12). Analyses were conducted on the intent-to-treat population, and health outcome measures evaluated using paired t tests. Results: Patients had a mean age of 58 years, body mass index of 28 kg/m2, 77% had contaminated wounds, and 84% completed 24-months follow-up. Concomitant procedures included fistula takedown (n = 24) or removal of infected previously placed mesh (n = 29). Hernia recurrence rate was 17% (n = 16). At the time of CVH repair, intraperitoneal placement of the biosynthetic mesh significantly increased the risk of recurrences (P ≤ 0.04). Surgical site infections (19/104) led to higher risk of recurrence (P < 0.01). Mean 24-month EQ-5D (index and visual analogue) and SF-12 physical component and mental scores improved from baseline (P < 0.05). Conclusions: In this prospective longitudinal study, biosynthetic absorbable mesh showed efficacy in terms of long-term recurrence and quality of life for CVH repair patients and offers an alternative to biologic and permanent synthetic meshes in these complex situations. PMID:28009747
Silveira, Raquel Kelner; Domingie, Sophie; Kirzin, Sylvain; de Melo Filho, Djalma Agripino; Portier, Guillaume
2017-10-01
Ventral mesh rectopexy (VMR) is a surgical option to treat rectal prolapse with pelvic floor dysfunction (PFD). Using synthetic surgical glue to fix the mesh to the anterior rectal wall after ventral dissection could be advantageous in comparison with sutured or stapled fixation. This study aimed to evaluate the safety and efficacy of synthetic surgical glue for mesh fixation compared with suture mesh fixation in VMR. This observational cohort study is a retrospective analysis conducted in a University Hospital Pelvic Surgery Center. All consecutive female patients (n = 176) who underwent laparoscopic or laparotomic VMR between January 2009 and December 2014 were included. Two groups were defined based on mesh fixation technique of the rectal wall: VMR with synthetic glue (n = 66) and VMR with suture (n = 110). The recurrence-free survival after VMR was determined by Kaplan-Meier method and multivariate analysis by Cox regression. Short-term postoperative complications, postoperative symptom improvement, the need for complementary treatment postoperatively, and procedure length were evaluated. A total of 176 females patients (mean age, 58.6 ± 13.7 years) underwent VMR with synthetic mesh. Mean recurrence-free survivals after VMR were 17.16 (CI 95% 16.54-17.80) and 17.33 (CI 95% 16.89-17.77) months in the glue group and the suture group, respectively (p > 0.05). Cox regression identified an independent effect on the recurrence risk of the external rectal prolapse, alone, or in combination with other anatomical abnormalities (HR = 0.37; CI 95% 0.14-0.93; p = 0.03). There was no significant difference of short-term postoperative morbidity, procedure length, postoperative symptom improvement, or need for complementary treatment postoperatively between suture versus glue groups (all p > 0.05). Use of glue to fix the mesh in VMR was safe and had no impact on outcomes. External prolapse was the unique significant predictive factor for recurrence.
Method and apparatus for connecting finite element meshes and performing simulations therewith
Dohrmann, Clark R.; Key, Samuel W.; Heinstein, Martin W.
2003-05-06
The present invention provides a method of connecting dissimilar finite element meshes. A first mesh, designated the master mesh, and a second mesh, designated the slave mesh, each have interface surfaces proximal the other. Each interface surface has a corresponding interface mesh comprising a plurality of interface nodes. Each slave interface node is assigned new coordinates locating the interface node on the interface surface of the master mesh. The slave interface surface is further redefined to be the projection of the slave interface mesh onto the master interface surface.
A methodology for quadrilateral finite element mesh coarsening
Staten, Matthew L.; Benzley, Steven; Scott, Michael
2008-03-27
High fidelity finite element modeling of continuum mechanics problems often requires using all quadrilateral or all hexahedral meshes. The efficiency of such models is often dependent upon the ability to adapt a mesh to the physics of the phenomena. Adapting a mesh requires the ability to both refine and/or coarsen the mesh. The algorithms available to refine and coarsen triangular and tetrahedral meshes are very robust and efficient. However, the ability to locally and conformally refine or coarsen all quadrilateral and all hexahedral meshes presents many difficulties. Some research has been done on localized conformal refinement of quadrilateral and hexahedralmore » meshes. However, little work has been done on localized conformal coarsening of quadrilateral and hexahedral meshes. A general method which provides both localized conformal coarsening and refinement for quadrilateral meshes is presented in this paper. This method is based on restructuring the mesh with simplex manipulations to the dual of the mesh. Finally, this method appears to be extensible to hexahedral meshes in three dimensions.« less
Adaptive Skin Meshes Coarsening for Biomolecular Simulation
Shi, Xinwei; Koehl, Patrice
2011-01-01
In this paper, we present efficient algorithms for generating hierarchical molecular skin meshes with decreasing size and guaranteed quality. Our algorithms generate a sequence of coarse meshes for both the surfaces and the bounded volumes. Each coarser surface mesh is adaptive to the surface curvature and maintains the topology of the skin surface with guaranteed mesh quality. The corresponding tetrahedral mesh is conforming to the interface surface mesh and contains high quality tetrahedral that decompose both the interior of the molecule and the surrounding region (enclosed in a sphere). Our hierarchical tetrahedral meshes have a number of advantages that will facilitate fast and accurate multigrid PDE solvers. Firstly, the quality of both the surface triangulations and tetrahedral meshes is guaranteed. Secondly, the interface in the tetrahedral mesh is an accurate approximation of the molecular boundary. In particular, all the boundary points lie on the skin surface. Thirdly, our meshes are Delaunay meshes. Finally, the meshes are adaptive to the geometry. PMID:21779137
Wu, Xujun; Wang, Yuru; Zhu, Cancan; Tong, Xiaowen; Yang, Ming; Yang, Li; Liu, Zhang; Huang, Weihong; Wu, Feng; Zong, Honghai; Li, Huaifang; He, Hongbing
2016-01-01
Synthetic and biological materials are commonly used for pelvic floor reconstruction. In this study, host tissue response and biomechanical properties of mesh fabricated from co-electrospun poly(l-lactide-co-caprolactone) (PLCL) and fibrinogen (Fg) were compared with those of polypropylene mesh (PPM) in a canine abdominal defect model. Macroscopic, microscopic, histological, and biomechanical evaluations were performed over a 24-week period. The results showed that PLCL/Fg mesh had similar host tissue responses but better initial vascularization and graft site tissue organization than PPM. The efficacy of the PLCL/Fg mesh was further examined in human pelvic floor reconstruction. Operation time, intraoperative blood loss, and pelvic organ prolapse quantification during 6-month follow-up were compared for patients receiving PLCL/Fg mesh versus PPM. According to the pelvic organ prolapse quantification scores, the anterior vaginal wall 3 cm proximal to the hymen point (Aa point), most distal edge of the cervix or vaginal cuff scar point (C point), and posterior fornix point (D point) showed significant improvement (P<0.01) at 1, 3, and 6 months for both groups compared with preoperatively. At 6 months, improvements at the Aa point in the PLCL/Fg group were significantly more (P<0.005) than the PPM group, indicating that, while both materials improve the patient symptoms, PLCL/Fg mesh resulted in more obvious improvement. PMID:26893556
Shekhter, A B; Guller, A E; Istranov, L P; Istranova, E V; Butnaru, D V; Vinarov, A Z; Zakharkina, O L; Kurkov, A V; Kantimerov, D F; Antonov, E N; Marisov, L V; Glybochko, P V
2015-01-01
to perform a comparative morphological study of biocompatibility, biodegradation, and tissue response to implantation of collagen matrices (scaffolds) for tissue engineering in urology and other areas of medicine. Nine matrix types, such as porous materials reconstructed from collagen solution; a collagen sponge-vicryl mesh composite; decellularized and freeze-dried bovine, equine, and fish dermis; small intestinal submucosa, decellularized bovine dura mater; and decellularized human femoral artery, were implanted subcutaneously in 225 rats. The tissues at the implantation site were investigated for a period of 5 to 90 days. Classical histology and nonlinear optical microscopy (NLOM) were applied. The investigations showed no rejection of all the collagen materials. The period of matrix bioresorption varied from 10 days for collagen sponges to 2 months for decellularized and freeze-dried vessels and vicryl meshes. Collagen was prone to macrophage resorption and enzymatic lysis, being replaced by granulation tissue and then fibrous tissue, followed by its involution. NLOM allowed the investigators to study the number, density, interposition, and spatial organization of collagen structures in the matrices and adjacent tissues, and their change over time during implantation. The performed investigation could recommend three matrices: hybrid collagen/vicryl composite; decellularized bovine dermis; and decellularized porcine small intestinal submucosa, which are most adequate for tissue engineering in urology. These and other collagen matrices may be used in different areas of regenerative medicine.
NASA Astrophysics Data System (ADS)
Alby, E.; Elter, R.; Ripoche, C.; Quere, N.; de Strasbourg, INSA
2013-07-01
In a geopolitical very complex context as the Gaza Strip it has to be dealt with an enhancement of an archaeological site. This site is the monastery of St. Hilarion. To enable a cultural appropriation of a place with several identified phases of occupation must undertake extensive archaeological excavation. Excavate in this geographical area is to implement emergency excavations, so the aim of such a project can be questioned for each mission. Real estate pressure is also a motivating setting the documentation because the large population density does not allow systematic studies of underground before construction projects. This is also during the construction of a road that the site was discovered. Site dimensions are 150 m by 80 m. It is located on a sand dune, 300 m from the sea. To implement the survey, four different levels of detail have been defined for terrestrial photogrammetry. The first level elements are similar to objects, capitals, fragment of columns, tiles for example. Modeling of small objects requires the acquisition of very dense point clouds (density: 1 point / 1 mm on average). The object must then be a maximum area of the sensor of the camera, while retaining in the field of view a reference pattern for the scaling of the point cloud generated. The pictures are taken at a short distance from the object, using the images at full resolution. The main obstacle to the modeling of objects is the presence of noise partly due to the studied materials (sand, smooth rock), which do not favor the detection of points of interest quality. Pretreatments of the cloud will be achieved meticulously since the ouster of points on a surface of a small object results in the formation of a hole with a lack of information, useful to resulting mesh. Level 2 focuses on the stratigraphic units such as mosaics. The monastery of St. Hilarion identifies thirteen floors of which has been documented years ago by silver photographs, scanned later. Modeling of pavements is to obtain a three-dimensional model of the mosaic in particular to analyze the subsidence, which it may be subjected. The dense point cloud can go beyond by including the geometric shapes of the pavement. The calculation mesh using high-density point cloud colorization allows cloud sufficient to final rendering. Levels 3 and 4 will allow the survey and representation of loci and sectors. Their modeling can be done by colored mesh or textured by a generic pattern but also by geometric primitives. This method requires the segmentation simple geometrical elements and creates a surface geometry by analysis of the sample points. Statistical tools allow the extraction plans meet the requirements of the operator can monitor quantitatively the quality of the final rendering. Each level has constraints on the accuracy of survey and types of representation especially from the point clouds, which are detailed in the complete article.
Liñero Arana, Ildefonso; Díaz Díaz, Oscar
2006-09-01
Seasonal variations of polychaetes in a Thalassia testudinum bed were studied from June 2000 to April 2001 in Chacopata, northeastern Venezuela. Eight replicate samples were taken monthly with a 15 cm diameter core and the sediment was passed through a 0.5 mm mesh sieve. A total of 1,013 specimens, belonging to 35 species, was collected. The monthly density ranged from 387 ind/m2 (September) to 1,735 ind/m2 in May (x = 989+/-449 ind/m2). Species richness was lowest in August and September (8) and highest (25) in April (x = 18.00+/-5.29). The shoot density of Thalassia showed an average of 284+/-77.60 shoots/m2, with extreme values in February (164) and May (422). Species diversity ranged from 1.25 in August and 3.33 bits/ind in December (x = 2.47+/-0.64). Significant positive correlations were detected among the number of Thalassia shoots, polychaete abundance and species richness, as well as among species richness, polychaete abundance and species diversity. Species number and average density were found within the intervals of mean values reported in similar studies. The higher number of species and organisms obtained in March-April and June-July can be attributed to the recruitment correlated with the regional up-welling.
User Manual for the PROTEUS Mesh Tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Micheal A.; Shemon, Emily R.
2015-06-01
This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a givenmore » mesh tool (such as .axial or .merge) can be used as “mesh” input for any of the mesh tools discussed in this manual.« less
Metal Bonded Titanium Diboride
1952-03-01
removed by leaching in a 1:1 solution of 99.5% acetic acid . Previous attempts to remove iron contaminati.on by leaching in hydrochloric acid resulted in...to cool with the furnace. The fired specimens were measured and sawed into two parts with a diamond cut off wheel . Density determinations were made...first ground on a cast iron lap with 100 mesh silicon carbide. This was followed by two stages of grinding with 500 grit and 800 grit boron carbide on a
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Ching-Fong; Pokharel, Reeju; Brand, Michael J.
Here, we developed a copper/tungsten (Cu/W) composite for mesoscale Materials Science applications using the novel High-Energy Diffraction Microscopy (HEDM) technique. Argon-atomized copper powder was selected as the starting raw powder and screened to remove the extremely large particle fraction. Tungsten particles were collected by milling and screening the -325 mesh tungsten powder between 500 and 635 mesh sieves. Hot pressing of screened Cu powder was performed at 900 °C in Ar/4 %H 2 atmosphere. XRD and ICP results show that the hot-pressed Cu sample consists of about 5 vol% Cu 2O, which is caused by the presence of oxygen onmore » the surface of the starting Cu powder. Hot pressing the copper powder in a pure hydrogen atmosphere was successful in removing most of the surface oxygen. Our process was also implemented for hot pressing the Cu/W composite. The density of the Cu/W composites hot pressed at 950 °C in pure hydrogen was about 94 % of the theoretical density (TD). The hot-pressed Cu/W composites were further hot isostatic pressed at 1050 °C in argon atmosphere, which results in 99.6 % of the TD with the designed Cu grain size and W particle distribution. Tensile specimens with D-notch were machined using the wire EDM method. Furthermore, the processing and consolidation of these materials will be discussed in detail. The HEDM images are also showed and discussed.« less
NASA Astrophysics Data System (ADS)
Raudah; Zulkifli
2018-03-01
The present research focuses on establishing the optimum conditions in converting coffee husk into a densified biomass fuel using starch as a binding agent. A Response Surface Methodology (RSM) approach using Box-Behnken experimental design with three levels (-1, 0, and +1) was employed to obtain the optimum level for each parameter. The briquettes wereproduced by compressing the mixture of coffee husk-starch in a piston and die assembly with the pressure of 2000 psi. Furthermore, starch percentage, pyrolysis time, and particle size were the input parameters for the algorithm. Bomb calorimeter was used to determine the heating value (HHV) of the solid fuel. The result of the study indicated that a combination of 34.71 mesh particle size, 110.93 min pyrolysis time, and 8% starch concentration werethe optimum variables.The HHV and density of the fuel were up to 5644.66 calgr-1 and 0.7069 grcm-3,respectively. The study showed that further research should be conducted to improve the briquette density therefore the coffee husk could be convert into commercialsolid fuel to replace the dependent on fossil fuel.
Poprawa, Izabela
2005-01-01
The eggs of Dactylobiotus dispar, similar to other Tardigrada eggs, are covered with two shells: the vitelline envelope and the chorion. Ultrastructural studies have shown that the oocyte actively participates in the formation of both shells. The process of egg capsule formation begins at the midpoint of vitellogenesis. The chorion at first appears as isolated cones resulting from the exocytotic activity of the oocyte and the ovarian epithelium. Subsequently, connections between the cones are formed. Three layers can be distinguished in the completely developed chorion: (1) the inner layer of medium electron density; (2) the middle, labyrinthine layer; (3) the outer layer of medium electron density with cones (future conical processes). After chorion formation, a vitelline envelope is secreted by the oocyte. The Dactylobiotus dispar egg is covered with small, conical processes with hooked tips. The surface of the chorion is covered with a mesh-like network consisting of elongated interstices. The egg capsule has no micropylar opening.
The YORP effect on 25 143 Itokawa
NASA Astrophysics Data System (ADS)
Breiter, S.; Bartczak, P.; Czekaj, M.; Oczujda, B.; Vokrouhlický, D.
2009-11-01
Context: The asteroid 25143 Itokawa is one of the candidates for the detection of the Yarkovsky-O'Keefe-Radzievskii-Paddack (YORP) effect in the rotation period. Previous studies were carried out up to the 196 608 facets triangulation model and were not able to provide a good theoretical estimate of this effect, raising questions about the influence of the mesh resolution and the centre of mass location on the evolution the rotation period. Aims: The YORP effect on Itokawa is computed for different topography models up to the highest resolution Gaskell mesh of 3 145 728 triangular faces in an attempt to find the best possible YORP estimate. Other, lower resolution models are also studied and the question of the dependence of the rotation period drift on the density distribution inhomogeneities is reexamined. A comparison is made with 433 Eros models possessing a similar resolution. Methods: The Rubincam approximation (zero conductivity) is assumed in the numerical simulation of the YORP effect in rotation period. The mean thermal radiation torques are summed over triangular facets assuming Keplerian heliocentric motion and uniform rotation around a body-fixed axis. Results: There is no evidence of YORP convergence in Gaskell model family. Differently simplified meshes may converge quickly to their parent models, but this does not prove the quality of YORP computed from the latter. We confirm the high sensitivity of the YORP effect to the fine details of the surface for 25 143 Itokawa and 433 Eros. The sensitivity of the Itokawa YORP to the centre of mass shift is weaker than in earlier works, but instead the results prove to be sensitive to the spin axis orientation in the body frame. Conclusions: Either the sensitivity of the YORP effect is a physical phenomenon and all present predictions are questionable, or the present thermal models are too simplified.
A spring system method for a mesh generation problem
NASA Astrophysics Data System (ADS)
Romanov, A.
2018-04-01
A new direct method for the 2d-mesh generation for a simply-connected domain using a spring system is observed. The method can be used with other methods to modify a mesh for growing solid problems. Advantages and disadvantages of the method are shown. Different types of boundary conditions are explored. The results of modelling for different target domains are given. Some applications for composite materials are studied.
Unstructured mesh methods for CFD
NASA Technical Reports Server (NTRS)
Peraire, J.; Morgan, K.; Peiro, J.
1990-01-01
Mesh generation methods for Computational Fluid Dynamics (CFD) are outlined. Geometric modeling is discussed. An advancing front method is described. Flow past a two engine Falcon aeroplane is studied. An algorithm and associated data structure called the alternating digital tree, which efficiently solves the geometric searching problem is described. The computation of an initial approximation to the steady state solution of a given poblem is described. Mesh generation for transient flows is described.
User Manual for the PROTEUS Mesh Tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Micheal A.; Shemon, Emily R
2016-09-19
PROTEUS is built around a finite element representation of the geometry for visualization. In addition, the PROTEUS-SN solver was built to solve the even-parity transport equation on a finite element mesh provided as input. Similarly, PROTEUS-MOC and PROTEUS-NEMO were built to apply the method of characteristics on unstructured finite element meshes. Given the complexity of real world problems, experience has shown that using commercial mesh generator to create rather simple input geometries is overly complex and slow. As a consequence, significant effort has been put into place to create multiple codes that help assist in the mesh generation and manipulation.more » There are three input means to create a mesh in PROTEUS: UFMESH, GRID, and NEMESH. At present, the UFMESH is a simple way to generate two-dimensional Cartesian and hexagonal fuel assembly geometries. The UFmesh input allows for simple assembly mesh generation while the GRID input allows the generation of Cartesian, hexagonal, and regular triangular structured grid geometry options. The NEMESH is a way for the user to create their own mesh or convert another mesh file format into a PROTEUS input format. Given that one has an input mesh format acceptable for PROTEUS, we have constructed several tools which allow further mesh and geometry construction (i.e. mesh extrusion and merging). This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a given mesh tool (such as .axial or .merge) can be used as “mesh” input for any of the mesh tools discussed in this manual.« less
NASA Astrophysics Data System (ADS)
Caviedes-Voullième, Daniel; García-Navarro, Pilar; Murillo, Javier
2012-07-01
SummaryHydrological simulation of rain-runoff processes is often performed with lumped models which rely on calibration to generate storm hydrographs and study catchment response to rain. In this paper, a distributed, physically-based numerical model is used for runoff simulation in a mountain catchment. This approach offers two advantages. The first is that by using shallow-water equations for runoff flow, there is less freedom to calibrate routing parameters (as compared to, for example, synthetic hydrograph methods). The second, is that spatial distributions of water depth and velocity can be obtained. Furthermore, interactions among the various hydrological processes can be modeled in a physically-based approach which may depend on transient and spatially distributed factors. On the other hand, the undertaken numerical approach relies on accurate terrain representation and mesh selection, which also affects significantly the computational cost of the simulations. Hence, we investigate the response of a gauged catchment with this distributed approach. The methodology consists of analyzing the effects that the mesh has on the simulations by using a range of meshes. Next, friction is applied to the model and the response to variations and interaction with the mesh is studied. Finally, a first approach with the well-known SCS Curve Number method is studied to evaluate its behavior when coupled with a shallow-water model for runoff flow. The results show that mesh selection is of great importance, since it may affect the results in a magnitude as large as physical factors, such as friction. Furthermore, results proved to be less sensitive to roughness spatial distribution than to mesh properties. Finally, the results indicate that SCS-CN may not be suitable for simulating hydrological processes together with a shallow-water model.
Physio-Microstructural Properties of Aerated Cement Slurry for Lightweight Structures
Salem, Talal; Hamadna, Sameer; Darsanasiri, A. G. N. D.; Soroushian, Parviz; Balchandra, Anagi; Al-Chaar, Ghassan
2018-01-01
Cementitious composites, including ferrocement and continuous fiber reinforced cement, are increasingly considered for building construction and repair. One alternative in processing of these composites is to infiltrate the reinforcement (continuous fibers or chicken mesh) with a flowable cementitious slurry. The relatively high density of cementitious binders, when compared with polymeric binders, are a setback in efforts to introduce cementitious composites as lower-cost, fire-resistant, and durable alternatives to polymer composites. Aeration of the slurry is an effective means of reducing the density of cementitious composites. This approach, however, compromises the mechanical properties of cementitious binders. An experimental program was undertaken in order to assess the potential for production of aerated slurry with a desired balance of density, mechanical performance, and barrier qualities. The potential for nondestructive monitoring of strength development in aerated cementitious slurry was also investigated. This research produced aerated slurries with densities as low as 0.9 g/cm3 with viable mechanical and barrier qualities for production of composites. The microstructure of these composites was also investigated. PMID:29649163
Physio-Microstructural Properties of Aerated Cement Slurry for Lightweight Structures.
Almalkawi, Areej T; Salem, Talal; Hamadna, Sameer; Darsanasiri, A G N D; Soroushian, Parviz; Balchandra, Anagi; Al-Chaar, Ghassan
2018-04-12
Cementitious composites, including ferrocement and continuous fiber reinforced cement, are increasingly considered for building construction and repair. One alternative in processing of these composites is to infiltrate the reinforcement (continuous fibers or chicken mesh) with a flowable cementitious slurry. The relatively high density of cementitious binders, when compared with polymeric binders, are a setback in efforts to introduce cementitious composites as lower-cost, fire-resistant, and durable alternatives to polymer composites. Aeration of the slurry is an effective means of reducing the density of cementitious composites. This approach, however, compromises the mechanical properties of cementitious binders. An experimental program was undertaken in order to assess the potential for production of aerated slurry with a desired balance of density, mechanical performance, and barrier qualities. The potential for nondestructive monitoring of strength development in aerated cementitious slurry was also investigated. This research produced aerated slurries with densities as low as 0.9 g/cm³ with viable mechanical and barrier qualities for production of composites. The microstructure of these composites was also investigated.
Unsteady density-current equations for highly curved terrain
NASA Technical Reports Server (NTRS)
Sivakumaran, N. S.; Dressler, R. F.
1989-01-01
New nonlinear partial differential equations containing terrain curvature and its rate of change are derived that describe the flow of an atmospheric density current. Unlike the classical hydraulic-type equations for density currents, the new equations are valid for two-dimensional, gradually varied flow over highly curved terrain, hence suitable for computing unsteady (or steady) flows over arbitrary mountain/valley profiles. The model assumes the atmosphere above the density current exerts a known arbitrary variable pressure upon the unknown interface. Later this is specialized to the varying hydrostatic pressure of the atmosphere above. The new equations yield the variable velocity distribution, the interface position, and the pressure distribution that contains a centrifugal component, often significantly larger than its hydrostatic component. These partial differential equations are hyperbolic, and the characteristic equations and characteristic directions are derived. Using these to form a characteristic mesh, a hypothetical unsteady curved-flow problem is calculated, not based upon observed data, merely as an example to illustrate the simplicity of their application to unsteady flows over mountains.
Melo, N F A C; Neumann-Leitão, S; Gusmão, L M O; Martins-Neto, F E; Palheta, G D A
2014-08-01
Lucifer faxoni (BORRADAILE, 1915) and L. typus (EDWARDS, 1837) are species first identified in the neritic and oceanic waters off the Amazon. Samplings were made aboard the vessel "Antares" at 22 stations in July and August, 2001 with a bongo net (500-µm mesh size). Hydrological data were taken simultaneously for comparative purposes. L. faxoni was present at thirteen of the fourteen neritic stations analysed, as well as at five of the eight oceanic stations. L. typus was present at three of the fourteen neritic stations and in one of the eight oceanic stations. The highest density of L. faxoni in the neritic province was 7,000 ind.m(-3) (St. 82) and 159 ind.m(-3) (St. 75) in the oceanic area. For L. typus, the highest density observed was 41 ind.m(-3) (St. 64) in the neritic province. In the oceanic province, the highest single density value was recorded at station 75 (5 ind.m(-3)). Overall, L. faxoni typically presented the highest densities.
Forrester, Joseph D; Gomez, Carlos A; Forrester, Jared A; Nguyen, Mike; Gregg, David; Deresinski, Stan; Banaei, Niaz; Weiser, Thomas G
2015-10-01
Fungal mesh infections are a rare complication of hernia repairs with mesh. The first case of Coccidioides spp. mesh infection is described, and a systematic literature review of all known fungal mesh infections was performed. Nine cases of fungal mesh infection are reviewed. Female and male patients are equally represented, median age is 49.5 years, and critical illness and preinfection antibiotic use were common. Fungal mesh infections are rare, but potentially fatal, complications of hernias repaired with mesh. © 2015 Blackwell Verlag GmbH.
Ashar, B S; Dang, J M; Krause, D; Luke, M C
2011-12-01
The FDA's Center for Devices and Radiological Health (CDRH) is responsible for providing reasonable assurance of safety and effectiveness of all medical devices marketed within the US. To date, CDRH has cleared numerous hernia mesh devices for general use, but has not cleared/approved any mesh devices intended for certain specific uses, such as for infected wounds, hernia prevention, biofilm reduction, or prevention of adhesions. CDRH is requesting that manufacturers seeking specific hernia mesh device labeling claims consult with the Agency to determine the level of evidence necessary for justifying such claims.
Design variability in web geometry of an orb-weaving spider.
Vollrath, F; Downes, M; Krackow, S
1997-10-01
We studied the effect of several variables (environmental and physiological) on web geometry in the garden cross spider Araneus diadematus. Variables were: web support, wind, temperature, humidity, and silk supply. All had an effect. The spiders generally attempted to fit their webs to the shape of the supporting frame (standard, small, vertical, or horizontal). Windy conditions (0.5 m s-1) during web construction caused spiders to build smaller and rounder webs, laying down fewer capture spirals while increasing the distances between capture-spiral meshes. Decreasing temperature from 24 degrees to 12 degrees C caused the capture spiral to have fewer and wider spaced meshes, which did not change overall capture area but reduced the length of capture-spiral threads laid down. Subsequent increase of temperature to 24 degrees C restored the number of meshes laid down, but the wider mesh was retained, causing the capture area to be increased over initial control values. Decreased humidity (from 70 to 20% rH) had the effect of reducing web and capture-spiral size, the latter by reducing mesh number while keeping mesh spacing constant. Subsequent increase of humidity to control level (70%) restored web and capture area. However, this was achieved by laying down capture meshes at larger distances, rather than returning to initial mesh numbers. Silk supply also had a strong effect. Webs built in unnaturally rapid succession by the same spider (4 in 24 h when 1 is the norm) became sequentially smaller, had fewer radii, shorter capture spirals, and were wider meshed.
Inaki, N; Waseda, M; Schurr, M O; Braun, M; Buess, G F
2007-02-01
Laparoscopic mesh fixation using a stapler can lead to complications such as nerve injury and bowel injury. However, mesh fixation by suturing with conventional laparoscopic instruments (CLI) is difficult because of limited degrees of freedom. A manual manipulator--Radius Surgical System (Radius)--whose tip can deflect and rotate, gives the surgeon two additional degrees of freedom. The aim of this study is to evaluate the introduction of Radius to mesh fixation in laparoscopic inguinal hernia repair. A model for inguinal hernia repair was prepared using animal organs in a trainer. Mesh fixation was performed using Radius, stapler, and CLI. Tensile strength during extraction of mesh toward the vertical direction, and execution time, were measured. The mean number of fixation points of Radius, stapler, and CLI was 9.3 +/- 1.5, 8.5 +/- 1.4, and 9.0 +/- 1.0, respectively. The mean tensile strength of fixation of mesh of Radius, stapler, and CLI was 140.7 +/- 48.9, 73.1 +/- 23.4, and 53.6 +/- 31.5 (N), respectively. The mean tensile strength per one fixation point by Radius, stapler, and CLI was 16.5 +/- 5.3, 8.7 +/- 2.8, and 6.3 +/- 3.6 (N), respectively. The mean execution time of Radius, stapler, and CLI was 479 +/- 108, 54 +/- 31, and 431 +/- 77 (sec), respectively. The mesh fixation by Radius was stronger than that by staples and CLI. Two additional degrees of freedom were useful in difficult angles. The introduction of Radius is feasible and facilitates the fixation of mesh with sutures in laparoscopic inguinal hernia repair.
Extrusion-Based 3D Printing of Hierarchically Porous Advanced Battery Electrodes.
Lacey, Steven D; Kirsch, Dylan J; Li, Yiju; Morgenstern, Joseph T; Zarket, Brady C; Yao, Yonggang; Dai, Jiaqi; Garcia, Laurence Q; Liu, Boyang; Gao, Tingting; Xu, Shaomao; Raghavan, Srinivasa R; Connell, John W; Lin, Yi; Hu, Liangbing
2018-03-01
A highly porous 2D nanomaterial, holey graphene oxide (hGO), is synthesized directly from holey graphene powder and employed to create an aqueous 3D printable ink without the use of additives or binders. Stable dispersions of hydrophilic hGO sheets in water (≈100 mg mL -1 ) can be readily achieved. The shear-thinning behavior of the aqueous hGO ink enables extrusion-based printing of fine filaments into complex 3D architectures, such as stacked mesh structures, on arbitrary substrates. The freestanding 3D printed hGO meshes exhibit trimodal porosity: nanoscale (4-25 nm through-holes on hGO sheets), microscale (tens of micrometer-sized pores introduced by lyophilization), and macroscale (<500 µm square pores of the mesh design), which are advantageous for high-performance energy storage devices that rely on interfacial reactions to promote full active-site utilization. To elucidate the benefit of (nano)porosity and structurally conscious designs, the additive-free architectures are demonstrated as the first 3D printed lithium-oxygen (Li-O 2 ) cathodes and characterized alongside 3D printed GO-based materials without nanoporosity as well as nanoporous 2D vacuum filtrated films. The results indicate the synergistic effect between 2D nanomaterials, hierarchical porosity, and overall structural design, as well as the promise of a freeform generation of high-energy-density battery systems. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Wang, Feiyan; Morten, Jan Petter; Spitzer, Klaus
2018-05-01
In this paper, we present a recently developed anisotropic 3-D inversion framework for interpreting controlled-source electromagnetic (CSEM) data in the frequency domain. The framework integrates a high-order finite-element forward operator and a Gauss-Newton inversion algorithm. Conductivity constraints are applied using a parameter transformation. We discretize the continuous forward and inverse problems on unstructured grids for a flexible treatment of arbitrarily complex geometries. Moreover, an unstructured mesh is more desirable in comparison to a single rectilinear mesh for multisource problems because local grid refinement will not significantly influence the mesh density outside the region of interest. The non-uniform spatial discretization facilitates parametrization of the inversion domain at a suitable scale. For a rapid simulation of multisource EM data, we opt to use a parallel direct solver. We further accelerate the inversion process by decomposing the entire data set into subsets with respect to frequencies (and transmitters if memory requirement is affordable). The computational tasks associated with each data subset are distributed to different processes and run in parallel. We validate the scheme using a synthetic marine CSEM model with rough bathymetry, and finally, apply it to an industrial-size 3-D data set from the Troll field oil province in the North Sea acquired in 2008 to examine its robustness and practical applicability.
NASA Astrophysics Data System (ADS)
Cui, Xiangyang; Li, She; Feng, Hui; Li, Guangyao
2017-05-01
In this paper, a novel triangular prism solid and shell interactive mapping element is proposed to solve the coupled magnetic-mechanical formulation in electromagnetic sheet metal forming process. A linear six-node "Triprism" element is firstly proposed for transient eddy current analysis in electromagnetic field. In present "Triprism" element, shape functions are given explicitly, and a cell-wise gradient smoothing operation is used to obtain the gradient matrices without evaluating derivatives of shape functions. In mechanical field analysis, a shear locking free triangular shell element is employed in internal force computation, and a data mapping method is developed to transfer the Lorentz force on solid into the external forces suffered by shell structure for dynamic elasto-plasticity deformation analysis. Based on the deformed triangular shell structure, a "Triprism" element generation rule is established for updated electromagnetic analysis, which means inter-transformation of meshes between the coupled fields can be performed automatically. In addition, the dynamic moving mesh is adopted for air mesh updating based on the deformation of sheet metal. A benchmark problem is carried out for confirming the accuracy of the proposed "Triprism" element in predicting flux density in electromagnetic field. Solutions of several EMF problems obtained by present work are compared with experiment results and those of traditional method, which are showing excellent performances of present interactive mapping element.
An Adaptive Mesh Algorithm: Mapping the Mesh Variables
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scannapieco, Anthony J.
2016-07-25
Both thermodynamic and kinematic variables must be mapped. The kinematic variables are defined on a separate kinematic mesh; it is the duel mesh to the thermodynamic mesh. The map of the kinematic variables is done by calculating the contributions of kinematic variables on the old thermodynamic mesh, mapping the kinematic variable contributions onto the new thermodynamic mesh and then synthesizing the mapped kinematic variables on the new kinematic mesh. In this document the map of the thermodynamic variables will be described.
NASA Astrophysics Data System (ADS)
Rigola, J.; Aljure, D.; Lehmkuhl, O.; Pérez-Segarra, C. D.; Oliva, A.
2015-08-01
The aim of this paper is to carry out a group of numerical experiments over the fluid flow through a valve reed, using the CFD&HT code TermoFluids, an unstructured and parallel object-oriented CFD code for accurate and reliable solving of industrial flows. Turbulent flow and its solution is a very complex problem due to there is a non-lineal interaction between viscous and inertial effects further complicated by their rotational nature, together with the three-dimensionality inherent in these types of flow and the non-steady state solutions. In this work, different meshes, geometrical conditions and LES turbulence models (WALE, VMS, QR and SIGMA) are tested and results compared. On the other hand, the fluid flow boundary conditions are obtained by means of the numerical simulation model of hermetic reciprocating compressors tool, NEST-compressor code. The numerical results presented are based on a specific geometry, where the valve gap opening percentage is 11% of hole diameter and Reynolds numbers given by the one-dimensional model is 4.22 × 105, with density meshes of approximately 8 million CVs. Geometrical aspects related with the orifice's shape and its influence on fluid flow behaviour and pressure drop are analysed in detail, furthermore, flow results for different valve openings are also studied.
NASA Astrophysics Data System (ADS)
de Lucas-Consuegra, Antonio; de la Osa, Ana R.; Calcerrada, Ana B.; Linares, José J.; Horwat, David
2016-07-01
This study reports the preparation, characterization and testing of a sputtered Pd mesh-like anode as an advanced electrocatalyst for H2 production from alkaline ethanol solutions in an Alkaline Membrane Electrolyzer (AEM). Pd anodic catalyst is prepared by magnetron sputtering technique onto a microfiber carbon paper support. Scanning Electron Microscopy images reveal that the used preparation technique enables to cover the surface of the carbon microfibers exposed to the Pd target, leading to a continuous network that also maintains part of the original carbon paper macroporosity. Such novel anodic architecture (organic binder free) presents an excellent electro-chemical performance, with a maximum current density of 700 mA cm-2 at 1.3 V, and, concomitantly, a large H2 production rate with low energy requirement compared to water electrolysis. Potassium hydroxide emerges as the best electrolyte, whereas temperature exerts the expected promotional effect up to 90 °C. On the other hand, a 1 mol L-1 ethanol solution is enough to guarantee an efficient fuel supply without any mass transfer limitation. The proposed system also demonstrates to remain stable over 150 h of operation along five consecutives cycles, producing highly pure H2 (99.999%) at the cathode and potassium acetate as the main anodic product.
Reflectance analysis of porosity gradient in nanostructured silicon layers
NASA Astrophysics Data System (ADS)
Jurečka, Stanislav; Imamura, Kentaro; Matsumoto, Taketoshi; Kobayashi, Hikaru
2017-12-01
In this work we study optical properties of nanostructured layers formed on silicon surface. Nanostructured layers on Si are formed in order to reach high suppression of the light reflectance. Low spectral reflectance is important for improvement of the conversion efficiency of solar cells and for other optoelectronic applications. Effective method of forming nanostructured layers with ultralow reflectance in a broad interval of wavelengths is in our approach based on metal assisted etching of Si. Si surface immersed in HF and H2O2 solution is etched in contact with the Pt mesh roller and the structure of the mesh is transferred on the etched surface. During this etching procedure the layer density evolves gradually and the spectral reflectance decreases exponentially with the depth in porous layer. We analyzed properties of the layer porosity by incorporating the porosity gradient into construction of the layer spectral reflectance theoretical model. Analyzed layer is splitted into 20 sublayers in our approach. Complex dielectric function in each sublayer is computed by using Bruggeman effective media theory and the theoretical spectral reflectance of modelled multilayer system is computed by using Abeles matrix formalism. Porosity gradient is extracted from the theoretical reflectance model optimized in comparison to the experimental values. Resulting values of the structure porosity development provide important information for optimization of the technological treatment operations.
Lu, Benzhuo; Zhou, Y C; Huber, Gary A; Bond, Stephen D; Holst, Michael J; McCammon, J Andrew
2007-10-07
A computational framework is presented for the continuum modeling of cellular biomolecular diffusion influenced by electrostatic driving forces. This framework is developed from a combination of state-of-the-art numerical methods, geometric meshing, and computer visualization tools. In particular, a hybrid of (adaptive) finite element and boundary element methods is adopted to solve the Smoluchowski equation (SE), the Poisson equation (PE), and the Poisson-Nernst-Planck equation (PNPE) in order to describe electrodiffusion processes. The finite element method is used because of its flexibility in modeling irregular geometries and complex boundary conditions. The boundary element method is used due to the convenience of treating the singularities in the source charge distribution and its accurate solution to electrostatic problems on molecular boundaries. Nonsteady-state diffusion can be studied using this framework, with the electric field computed using the densities of charged small molecules and mobile ions in the solvent. A solution for mesh generation for biomolecular systems is supplied, which is an essential component for the finite element and boundary element computations. The uncoupled Smoluchowski equation and Poisson-Boltzmann equation are considered as special cases of the PNPE in the numerical algorithm, and therefore can be solved in this framework as well. Two types of computations are reported in the results: stationary PNPE and time-dependent SE or Nernst-Planck equations solutions. A biological application of the first type is the ionic density distribution around a fragment of DNA determined by the equilibrium PNPE. The stationary PNPE with nonzero flux is also studied for a simple model system, and leads to an observation that the interference on electrostatic field of the substrate charges strongly affects the reaction rate coefficient. The second is a time-dependent diffusion process: the consumption of the neurotransmitter acetylcholine by acetylcholinesterase, determined by the SE and a single uncoupled solution of the Poisson-Boltzmann equation. The electrostatic effects, counterion compensation, spatiotemporal distribution, and diffusion-controlled reaction kinetics are analyzed and different methods are compared.
Complications of pelvic organ prolapse surgery and methods of prevention.
de Tayrac, Renaud; Sentilhes, Loic
2013-11-01
The aim was to review complications associated with pelvic organ prolapse surgery. Every 4 years and as part of the Fifth International Collaboration on Incontinence we reviewed the English-language scientific literature after searching PubMed, Medline, Cochrane library and Cochrane database of systematic reviews, published up to January 2012. Publications were classified as level 1 evidence (randomised controlled trials [RCT] or systematic reviews), level 2 (poor quality RCT, prospective cohort studies), level 3 (case series or retrospective studies) and level 4 (case reports). The highest level of evidence was utilised by the committee to make evidence-based recommendations based upon the Oxford grading system. Grade A recommendation usually depends on consistent level 1 evidence. Grade B recommendation usually depends on consistent level 2 and/or 3 studies, or "majority evidence" from RCTs. Grade C recommendation usually depends on level 4 studies or "majority evidence from level 2/3 studies or Delphi processed expert opinion. Grade D "no recommendation possible" would be used where the evidence is inadequate or conflicting and when expert opinion is delivered without a formal analytical process, such as by Delphi. Transvaginal mesh has a higher re-operation rate than native tissue vaginal repairs (grade A). If a synthetic mesh is placed via the vaginal route, it is recommended that a macroporous polypropylene monofilament mesh should be used. At sacral colpopexy mesh should not be introduced or sutured via the vaginal route and silicone-coated polyester, porcine dermis, fascia lata and polytetrafluoroethylene meshes are not recommended as grafts. Hysterectomy should also be avoided (grade B). There is no evidence to recommend routine local or systemic oestrogen therapy before or after prolapse surgery using mesh. The first cases should be undertaken with the guidance of an experienced surgeon in the relevant technique (grade C). Expert opinion suggests that by whatever the surgical route pre-operative urinary tract infections are treated, smoking is ceased and antibiotic prophylaxis is undertaken. It is recommended that a non-absorbable synthetic mesh should not be inserted into the rectovaginal septum when a rectal injury occurs. The placement of a non-absorbable synthetic mesh into the vesicovaginal septum may be considered after a bladder injury has been repaired, if the repair is considered to be satisfactory. It is possible to perform a hysterectomy in association with the introduction of a non-absorbable synthetic mesh inserted vaginally, but this is not recommended routinely.
Template-free synthesis of multifunctional carbonaceous microcone forests
NASA Astrophysics Data System (ADS)
Wang, Qiang; Yang, Lei; Dai, Bing; Bai, Jie; Yang, Zhenhuai; Guo, Shuai; He, Yurong; Han, Jiecai; Zhu, Jiaqi
2018-01-01
Forests of vertically aligned carbonaceous microcones are fabricated directly on a nickel mesh by microwave-plasma-assisted chemical vapor deposition. The microstructure is formed through a simple one-step process involving self-assembly. The fabricated composite exhibits superhydrophobicity and superoleophilicity as well as low density, owing to which it floats on water and can be used for the in-situ separation of oil from water at the oil/water interface. Furthermore, the composite exhibits pH responsivity, and its water permeability can be varied simply by altering the pH of the aqueous solution. In addition, the composite is suitable for use as an electrode material for supercapacitors owing to its large geometric surface area, porous structure, and superior electrical properties, which allow for fast ion and electron transportation. Thus, this composite consisting of forests of vertically aligned carbonaceous microcones on a nickel mesh is expected to find use in a wide range of fields and applications, including in environmental cleanup, flow switches, and energy storage devices.
Superconducting transition temperature of a boron nitride layer with a high niobium coverage.
NASA Astrophysics Data System (ADS)
Vazquez, Gerardo; Magana, Fernando
We explore the possibility of inducing superconductivity in a Boron Nitride (BN) sheet, by doping its surface with Nb atoms sitting on the center of the hexagons. We used first-principles density functional theory in the general gradient approximation. The Quantum-Espresso package was used with norm conserving pseudo potentials. The structure considered was relaxed to their minimum energy configuration. Phonon frequencies were calculated using the linear-response technique on several phonon wave-vector meshes. The electron-phonon coupling parameter was calculated for a number of k meshes. The superconducting critical temperature was estimated using the Allen-Dynes formula with μ* = 0.1 - 0.15. We note that Nb is a good candidate material to show a superconductor transition for the BN-metal system. We thank Dirección General de Asuntos del Personal Académico de la Universidad Nacional Autónoma de México, partial financial support by Grant IN-106514 and we also thank Miztli Super-Computing center the technical assistance.
The Robustness Analysis of Wireless Sensor Networks under Uncertain Interference
Deng, Changjian
2013-01-01
Based on the complex network theory, robustness analysis of condition monitoring wireless sensor network under uncertain interference is present. In the evolution of the topology of sensor networks, the density weighted algebraic connectivity is taken into account, and the phenomenon of removing and repairing the link and node in the network is discussed. Numerical simulation is conducted to explore algebraic connectivity characteristics and network robustness performance. It is found that nodes density has the effect on algebraic connectivity distribution in the random graph model; high density nodes carry more connections, use more throughputs, and may be more unreliable. Moreover, the results show that, when network should be more error tolerant or robust by repairing nodes or adding new nodes, the network should be better clustered in median and high scale wireless sensor networks and be meshing topology in small scale networks. PMID:24363613
Chang, Xing; Zhou, Xin; Luo, Linzhi; Yang, Chengjia; Pan, Hui; Zhang, Shuyang
2017-09-12
This study aimed to identify hotspots in research on clinical competence measurements from 2012 to 2016. The authors retrieved literature published between 2012 and 2016 from PubMed using selected medical subject headings (MeSH) terms. They used BibExcel software to generate high-frequency MeSH terms and identified hotspots by co-word analysis and cluster analysis. The authors searched 588 related articles and identified 31 high-frequency MeSH terms. In addition, they obtained 6 groups of high-frequency MeSH terms that reflected the domain hotspots. This study identified 6 hotspots of domain research, including studies on influencing factors and perception evaluation, improving and developing measurement tools, feedback measurement, measurement approaches based on computer simulation, the measurement of specific students in different learning phases, and the measurement of students' communication ability. All of these research topics could provide useful information for educators and researchers to continually conduct in-depth studies.
Grundy, Brian R.
1981-01-01
The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume.
Grundy, B.R.
1981-09-29
The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume. 2 figs.
The complete digital workflow in fixed prosthodontics: a systematic review.
Joda, Tim; Zarone, Fernando; Ferrari, Marco
2017-09-19
The continuous development in dental processing ensures new opportunities in the field of fixed prosthodontics in a complete virtual environment without any physical model situations. The aim was to compare fully digitalized workflows to conventional and/or mixed analog-digital workflows for the treatment with tooth-borne or implant-supported fixed reconstructions. A PICO strategy was executed using an electronic (MEDLINE, EMBASE, Google Scholar) plus manual search up to 2016-09-16 focusing on RCTs investigating complete digital workflows in fixed prosthodontics with regard to economics or esthetics or patient-centered outcomes with or without follow-up or survival/success rate analysis as well as complication assessment of at least 1 year under function. The search strategy was assembled from MeSH-Terms and unspecific free-text words: {(("Dental Prosthesis" [MeSH]) OR ("Crowns" [MeSH]) OR ("Dental Prosthesis, Implant-Supported" [MeSH])) OR ((crown) OR (fixed dental prosthesis) OR (fixed reconstruction) OR (dental bridge) OR (implant crown) OR (implant prosthesis) OR (implant restoration) OR (implant reconstruction))} AND {("Computer-Aided Design" [MeSH]) OR ((digital workflow) OR (digital technology) OR (computerized dentistry) OR (intraoral scan) OR (digital impression) OR (scanbody) OR (virtual design) OR (digital design) OR (cad/cam) OR (rapid prototyping) OR (monolithic) OR (full-contour))} AND {("Dental Technology" [MeSH) OR ((conventional workflow) OR (lost-wax-technique) OR (porcelain-fused-to-metal) OR (PFM) OR (implant impression) OR (hand-layering) OR (veneering) OR (framework))} AND {(("Study, Feasibility" [MeSH]) OR ("Survival" [MeSH]) OR ("Success" [MeSH]) OR ("Economics" [MeSH]) OR ("Costs, Cost Analysis" [MeSH]) OR ("Esthetics, Dental" [MeSH]) OR ("Patient Satisfaction" [MeSH])) OR ((feasibility) OR (efficiency) OR (patient-centered outcome))}. Assessment of risk of bias in selected studies was done at a 'trial level' including random sequence generation, allocation concealment, blinding, completeness of outcome data, selective reporting, and other bias using the Cochrane Collaboration tool. A judgment of risk of bias was assigned if one or more key domains had a high or unclear risk of bias. An official registration of the systematic review was not performed. The systematic search identified 67 titles, 32 abstracts thereof were screened, and subsequently, three full-texts included for data extraction. Analysed RCTs were heterogeneous without follow-up. One study demonstrated that fully digitally produced dental crowns revealed the feasibility of the process itself; however, the marginal precision was lower for lithium disilicate (LS2) restorations (113.8 μm) compared to conventional metal-ceramic (92.4 μm) and zirconium dioxide (ZrO2) crowns (68.5 μm) (p < 0.05). Another study showed that leucite-reinforced glass ceramic crowns were esthetically favoured by the patients (8/2 crowns) and clinicians (7/3 crowns) (p < 0.05). The third study investigated implant crowns. The complete digital workflow was more than twofold faster (75.3 min) in comparison to the mixed analog-digital workflow (156.6 min) (p < 0.05). No RCTs could be found investigating multi-unit fixed dental prostheses (FDP). The number of RCTs testing complete digital workflows in fixed prosthodontics is low. Scientifically proven recommendations for clinical routine cannot be given at this time. Research with high-quality trials seems to be slower than the industrial progress of available digital applications. Future research with well-designed RCTs including follow-up observation is compellingly necessary in the field of complete digital processing.