Which drugs are risk factors for the development of gastroesophageal reflux disease?
Mungan, Zeynel; Pınarbaşı Şimşek, Binnur
2017-12-01
Gastroesophageal reflux disease (GERD), which is common in many communities, is associated with structural factors, eating habits, and the use of certain drugs. The use of such drugs can lead to the emergence of GERD and can also exacerbate existing reflux symptoms. These drugs can contribute to GERD by directly causing mucosal damage, by reducing lower esophageal sphincter pressure (LESP), or by affecting esophagogastric motility. In this article, we report our investigation of the relationships between GERD and medications within the scope of the "Turkish GERD Consensus Group." For the medication groups for which sufficient data were obtained (Figure 1), a systematic literature review in English was conducted using the keywords "gastroesophageal reflux" [MeSH Terms] and "anti-inflammatory agents, non-steroidal" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "acetylsalicylic acid" [MeSH Terms], "gastroesophageal reflux" [All Fields] and "estrogenic agents" [All Fields], "gastroesophageal reflux" [All Fields] and "progesterones" [All Fields], "gastroesophageal reflux" [All Fields] and "hormone replacement therapy" [All Fields], "gastroesophageal reflux" [MeSH Terms] and "diphosphonates" [MeSH Terms] OR "diphosphonates" [All Fields], "calcium channel blockers" [MeSH Terms] and "gastroesophageal reflux" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "nitrates" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "antidepressive agents" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "benzodiazepines" [MeSH Terms] and "hypnotic drugs" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "cholinergic antagonists" [MeSH Terms], "gastroesophageal reflux" [MeSH Terms] and "theophylline" [MeSH Terms], and "gastroesophageal reflux [MeSH Terms] AND "anti-asthmatic agents" [MeSH Terms]. The studies were analyzed and the results are presented here.
A Moving Mesh Finite Element Algorithm for Singular Problems in Two and Three Space Dimensions
NASA Astrophysics Data System (ADS)
Li, Ruo; Tang, Tao; Zhang, Pingwen
2002-04-01
A framework for adaptive meshes based on the Hamilton-Schoen-Yau theory was proposed by Dvinsky. In a recent work (2001, J. Comput. Phys.170, 562-588), we extended Dvinsky's method to provide an efficient moving mesh algorithm which compared favorably with the previously proposed schemes in terms of simplicity and reliability. In this work, we will further extend the moving mesh methods based on harmonic maps to deal with mesh adaptation in three space dimensions. In obtaining the variational mesh, we will solve an optimization problem with some appropriate constraints, which is in contrast to the traditional method of solving the Euler-Lagrange equation directly. The key idea of this approach is to update the interior and boundary grids simultaneously, rather than considering them separately. Application of the proposed moving mesh scheme is illustrated with some two- and three-dimensional problems with large solution gradients. The numerical experiments show that our methods can accurately resolve detail features of singular problems in 3D.
Bhattarai, Arjun Kumar; Zarrin, Aein; Lee, Joon
2017-01-01
To investigate the public health domains, key informatics concepts, and information and communications technologies (ICTs) applied in articles that are tagged with the MeSH term "public health informatics" and primarily focus on applying ICTs to public health. The MeSH term "public health informatics" was searched on MEDLINE-PubMed. The results of the search were then screened in two steps in order to only include articles about applying ICTs to public health problems. First, articles were screened based on their titles and abstracts. Second, a full-text review was conducted to ensure the relevance of the included articles. All articles were charted based on public health domain, information technology, article type, and informatics concept. 515 articles were included. Communicable disease monitoring (N=235), public health policy and research (N=201), and public health awareness (N=85) constituted the majority of the articles. Inconsistent results were found regarding the validity of syndromic surveillance and the effectiveness of PHI integration within the healthcare systems. PHI articles with an ICT focus cover a wide range of themes. Collectively, the included articles emphasized the need for further research in interoperability, data quality, appropriate data sources, accessible health information, and communication. The limitations of the study include:1) only one database was searched; 2) by using MeSH tags as a selection criterion, PHI articles without the "public health informatics" MeSH term were excluded. Due to the multi-disciplinary nature of PHI, MeSH identifiers were not assigned consistently. Current MeSH-tagged articles indicate that a comprehensive approach is required to integrate PHI into the healthcare system.
Discontinuous Skeletal Gradient Discretisation methods on polytopal meshes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Di Pietro, Daniele A.; Droniou, Jérôme; Manzini, Gianmarco
Here, in this work we develop arbitrary-order Discontinuous Skeletal Gradient Discretisations (DSGD) on general polytopal meshes. Discontinuous Skeletal refers to the fact that the globally coupled unknowns are broken polynomials on the mesh skeleton. The key ingredient is a high-order gradient reconstruction composed of two terms: (i) a consistent contribution obtained mimicking an integration by parts formula inside each element and (ii) a stabilising term for which sufficient design conditions are provided. An example of stabilisation that satisfies the design conditions is proposed based on a local lifting of high-order residuals on a Raviart–Thomas–Nédélec subspace. We prove that the novelmore » DSGDs satisfy coercivity, consistency, limit-conformity, and compactness requirements that ensure convergence for a variety of elliptic and parabolic problems. Lastly, links with Hybrid High-Order, non-conforming Mimetic Finite Difference and non-conforming Virtual Element methods are also studied. Numerical examples complete the exposition.« less
Discontinuous Skeletal Gradient Discretisation methods on polytopal meshes
Di Pietro, Daniele A.; Droniou, Jérôme; Manzini, Gianmarco
2017-11-21
Here, in this work we develop arbitrary-order Discontinuous Skeletal Gradient Discretisations (DSGD) on general polytopal meshes. Discontinuous Skeletal refers to the fact that the globally coupled unknowns are broken polynomials on the mesh skeleton. The key ingredient is a high-order gradient reconstruction composed of two terms: (i) a consistent contribution obtained mimicking an integration by parts formula inside each element and (ii) a stabilising term for which sufficient design conditions are provided. An example of stabilisation that satisfies the design conditions is proposed based on a local lifting of high-order residuals on a Raviart–Thomas–Nédélec subspace. We prove that the novelmore » DSGDs satisfy coercivity, consistency, limit-conformity, and compactness requirements that ensure convergence for a variety of elliptic and parabolic problems. Lastly, links with Hybrid High-Order, non-conforming Mimetic Finite Difference and non-conforming Virtual Element methods are also studied. Numerical examples complete the exposition.« less
MeSH key terms for validation and annotation of gene expression clusters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rechtsteiner, A.; Rocha, L. M.
2004-01-01
Integration of different sources of information is a great challenge for the analysis of gene expression data, and for the field of Functional Genomics in general. As the availability of numerical data from high-throughput methods increases, so does the need for technologies that assist in the validation and evaluation of the biological significance of results extracted from these data. In mRNA assaying with microarrays, for example, numerical analysis often attempts to identify clusters of co-expressed genes. The important task to find the biological significance of the results and validate them has so far mostly fallen to the biological expert whomore » had to perform this task manually. One of the most promising avenues to develop automated and integrative technology for such tasks lies in the application of modern Information Retrieval (IR) and Knowledge Management (KM) algorithms to databases with biomedical publications and data. Examples of databases available for the field are bibliographic databases c ntaining scientific publications (e.g. MEDLINE/PUBMED), databases containing sequence data (e.g. GenBank) and databases of semantic annotations (e.g. the Gene Ontology Consortium and Medical Subject Headings (MeSH)). We present here an approach that uses the MeSH terms and their concept hierarchies to validate and obtain functional information for gene expression clusters. The controlled and hierarchical MeSH vocabulary is used by the National Library of Medicine (NLM) to index all the articles cited in MEDLINE. Such indexing with a controlled vocabulary eliminates some of the ambiguity due to polysemy (terms that have multiple meanings) and synonymy (multiple terms have similar meaning) that would be encountered if terms would be extracted directly from the articles due to differing article contexts or author preferences and background. Further, the hierarchical organization of the MeSH terms can illustrate the conceptuallfunctional relationships of genes associated with MeSH terms. MeSH terms can be associated with genes through co-occurrence of these in MEDLINE citations, i.e. the genes occur in titles or abstracts and the MeSH terms are assigned by experts. To identify MeSH terms associated with a group of genes we used the tool MESHGENE developed at the Information Dynamics Lab at HP Labs (http://www-idl.hpl.hp.com/meshgene/). When presented with a list of human genes, MESHGENE uses some sophisticated techniques to search for these gene symbols in the titles and abstracts of all MEDLINE citations. MeSH terms and the number of co-occurrences can be retrieved. Gene symbols that are aliases of each other are pooled from several databases. This addresses the problem of synonymy, the fact that several symbols can refer to the same gene. MESHGENE employs some sophisticated algorithms that disregards symbols that are likely to be acronyms for other concepts than a gene. This addresses the problem of polysemy, i.e. possible multiple meanings of a gene symbol. We applied our approach to gene expression data from herpes virus infected human fibroblast cells. The data contains 12 time-points, between 1/2 hrs and 48 hrs after infection. Singular Value Decomposition was used to identify the dominant modes of expression. 75% of the variance in the expression data was captured by the first two modes, the first exhibiting a monotonly increasing expression pattern and the second a more transient pattern. Projection of the gene expression vectors onto this first two modes identified 3 statistically significant clusters of co-expressed genes. 500 genes from cluster 1 and 300 genes from clusters 2 and 3 each were uploaded to MESHGENE and the MeSH terms and co-occurrence values were retrieved. MeSH terms were also obtained for 5 groups of randomly selected genes with similar numbers of genes. The log was taken of the co-occurrence values and for each MeSH term these log co-occurrence values were summed for each group over the genes in that group. A matrix with 8 columns for the 8 groups of genes and with 14,000 rows with the MeSH terms was obtained. To analyze this association matrix we used a Latent Semantic Analysis (LSA) approach. We applied SVD to this gene-group vs. MeSH term association matrix. The first 2 modes that capture most of the variation (and therefore most times also information) in the association matrix were highly associated with MeSH terms that occurred uniquely or disproportionally in the 3 gene clusters. MeSH terms highly associated with the 5 groups of randomly selected genes were associated with the lower modes. These modes seem to just capture 'noise' in the association matrix. This result by itself is of great interest for gene expression analysis. We were able to show that the 3 clusters of genes not only separated in 'expression space' but also in the MeSH term space with which they are associated through the literature.« less
SEAODV: A Security Enhanced AODV Routing Protocol for Wireless Mesh Networks
NASA Astrophysics Data System (ADS)
Li, Celia; Wang, Zhuang; Yang, Cungang
In this paper, we propose a Security Enhanced AODV routing protocol (SEAODV) for wireless mesh networks (WMN). SEAODV employs Blom's key pre-distribution scheme to compute the pairwise transient key (PTK) through the flooding of enhanced HELLO message and subsequently uses the established PTK to distribute the group transient key (GTK). PTK and GTK authenticate unicast and broadcast routing messages respectively. In WMN, a unique PTK is shared by each pair of nodes, while GTK is shared secretly between the node and all its one-hop neighbours. A message authentication code (MAC) is attached as the extension to the original AODV routing message to guarantee the message's authenticity and integrity in a hop-by-hop fashion. Security analysis and performance evaluation show that SEAODV is more effective in preventing identified routing attacks and outperforms ARAN and SAODV in terms of computation cost and route acquisition latency.
Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology
Fu, Tian-Ming; Hong, Guosong; Viveros, Robert D.; Zhou, Tao
2017-01-01
Implantable electrical probes have led to advances in neuroscience, brain−machine interfaces, and treatment of neurological diseases, yet they remain limited in several key aspects. Ideally, an electrical probe should be capable of recording from large numbers of neurons across multiple local circuits and, importantly, allow stable tracking of the evolution of these neurons over the entire course of study. Silicon probes based on microfabrication can yield large-scale, high-density recording but face challenges of chronic gliosis and instability due to mechanical and structural mismatch with the brain. Ultraflexible mesh electronics, on the other hand, have demonstrated negligible chronic immune response and stable long-term brain monitoring at single-neuron level, although, to date, it has been limited to 16 channels. Here, we present a scalable scheme for highly multiplexed mesh electronics probes to bridge the gap between scalability and flexibility, where 32 to 128 channels per probe were implemented while the crucial brain-like structure and mechanics were maintained. Combining this mesh design with multisite injection, we demonstrate stable 128-channel local field potential and single-unit recordings from multiple brain regions in awake restrained mice over 4 mo. In addition, the newly integrated mesh is used to validate stable chronic recordings in freely behaving mice. This scalable scheme for mesh electronics together with demonstrated long-term stability represent important progress toward the realization of ideal implantable electrical probes allowing for mapping and tracking single-neuron level circuit changes associated with learning, aging, and neurodegenerative diseases. PMID:29109247
Assigning categorical information to Japanese medical terms using MeSH and MEDLINE.
Onogi, Yuzo
2007-01-01
This paper reports on the assigning of MeSH (Medical Subject Headings) categories to Japanese terms in an English-Japanese dictionary using the titles and abstracts of articles indexed in MEDLINE. In a previous study, 30,000 of 80,000 terms in the dictionary were mapped to MeSH terms by normalized comparison. It was reasoned that if the remaining dictionary terms appeared in MEDLINE-indexed articles that are indexed using MeSH terms, then relevancies between the dictionary terms and MeSH terms could be calculated, and thus MeSH categories assigned. This study compares two approaches for calculating the weight matrix. One is the TF*IDF method and the other uses the inner product of two weight matrices. About 20,000 additional dictionary terms were identified in MEDLINE-indexed articles published between 2000 and 2004. The precision and recall of these algorithms were evaluated separately for MeSH terms and non-MeSH terms. Unfortunately, the precision and recall of the algorithms was not good, but this method will help with manual assignment of MeSH categories to dictionary terms.
Field test of quantum key distribution in the Tokyo QKD Network.
Sasaki, M; Fujiwara, M; Ishizuka, H; Klaus, W; Wakui, K; Takeoka, M; Miki, S; Yamashita, T; Wang, Z; Tanaka, A; Yoshino, K; Nambu, Y; Takahashi, S; Tajima, A; Tomita, A; Domeki, T; Hasegawa, T; Sakai, Y; Kobayashi, H; Asai, T; Shimizu, K; Tokura, T; Tsurumaru, T; Matsui, M; Honjo, T; Tamaki, K; Takesue, H; Tokura, Y; Dynes, J F; Dixon, A R; Sharpe, A W; Yuan, Z L; Shields, A J; Uchikoga, S; Legré, M; Robyr, S; Trinkler, P; Monat, L; Page, J-B; Ribordy, G; Poppe, A; Allacher, A; Maurhart, O; Länger, T; Peev, M; Zeilinger, A
2011-05-23
A secure communication network with quantum key distribution in a metropolitan area is reported. Six different QKD systems are integrated into a mesh-type network. GHz-clocked QKD links enable us to demonstrate the world-first secure TV conferencing over a distance of 45km. The network includes a commercial QKD product for long-term stable operation, and application interface to secure mobile phones. Detection of an eavesdropper, rerouting into a secure path, and key relay via trusted nodes are demonstrated in this network.
Meshable: searching PubMed abstracts by utilizing MeSH and MeSH-derived topical terms.
Kim, Sun; Yeganova, Lana; Wilbur, W John
2016-10-01
Medical Subject Headings (MeSH(®)) is a controlled vocabulary for indexing and searching biomedical literature. MeSH terms and subheadings are organized in a hierarchical structure and are used to indicate the topics of an article. Biologists can use either MeSH terms as queries or the MeSH interface provided in PubMed(®) for searching PubMed abstracts. However, these are rarely used, and there is no convenient way to link standardized MeSH terms to user queries. Here, we introduce a web interface which allows users to enter queries to find MeSH terms closely related to the queries. Our method relies on co-occurrence of text words and MeSH terms to find keywords that are related to each MeSH term. A query is then matched with the keywords for MeSH terms, and candidate MeSH terms are ranked based on their relatedness to the query. The experimental results show that our method achieves the best performance among several term extraction approaches in terms of topic coherence. Moreover, the interface can be effectively used to find full names of abbreviations and to disambiguate user queries. https://www.ncbi.nlm.nih.gov/IRET/MESHABLE/ CONTACT: sun.kim@nih.gov Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.
Why language matters: a tour through hand hygiene literature.
Pires, Daniela; Tartari, Ermira; Bellissimo-Rodrigues, Fernando; Pittet, Didier
2017-01-01
Hand hygiene has evolved over the last decades and many terminologies emerged. We aimed to analyse the evolution in the frequency of utilization of key hand hygiene terms in the literature along the years. We identified keywords and Medical Subject Headings (MeSH) used in MEDLINE® indexation related to hand hygiene by searching international guidelines and the MeSH database. We performed a MEDLINE® search combining the selected keywords and MeSH and analysed the number of publications retrieved yearly. The literature search yielded 9019 publications when all hand hygiene related search terms were combined, between 1921 and November 2016. The total number of publications per year increased from a median of 4 (IQR 3, 6) in the 1950's to 554 (IQR 478, 583) between 2011 and 2015. The most frequently used keywords are hand disinfection, hand hygiene, hand washing, handrub, hand sanitizer and alcohol-based hand rub (ABHR). Until the 1990s, hand disinfection and hand washing were the most frequently used terms. Whilst the last decade has seen a remarkable increase in publications mentioning hand disinfection and hand hygiene and for the first time handrub, hand sanitizers and ABHR were introduced in the literature. Hand disinfection, hand hygiene and hand sanitizers are the main MeSH used by MEDLINE®. Since 2013 hand hygiene is the most frequently used MeSH and keyword. The change seen in literature in the last two decades, from hand washing and hand disinfection to hand hygiene, most probably reflect the paradigm shift favouring use of ABHR over soap and water promoted by international guidelines in the early 2000s.
A knowledge-driven approach to biomedical document conceptualization.
Zheng, Hai-Tao; Borchert, Charles; Jiang, Yong
2010-06-01
Biomedical document conceptualization is the process of clustering biomedical documents based on ontology-represented domain knowledge. The result of this process is the representation of the biomedical documents by a set of key concepts and their relationships. Most of clustering methods cluster documents based on invariant domain knowledge. The objective of this work is to develop an effective method to cluster biomedical documents based on various user-specified ontologies, so that users can exploit the concept structures of documents more effectively. We develop a flexible framework to allow users to specify the knowledge bases, in the form of ontologies. Based on the user-specified ontologies, we develop a key concept induction algorithm, which uses latent semantic analysis to identify key concepts and cluster documents. A corpus-related ontology generation algorithm is developed to generate the concept structures of documents. Based on two biomedical datasets, we evaluate the proposed method and five other clustering algorithms. The clustering results of the proposed method outperform the five other algorithms, in terms of key concept identification. With respect to the first biomedical dataset, our method has the F-measure values 0.7294 and 0.5294 based on the MeSH ontology and gene ontology (GO), respectively. With respect to the second biomedical dataset, our method has the F-measure values 0.6751 and 0.6746 based on the MeSH ontology and GO, respectively. Both results outperforms the five other algorithms in terms of F-measure. Based on the MeSH ontology and GO, the generated corpus-related ontologies show informative conceptual structures. The proposed method enables users to specify the domain knowledge to exploit the conceptual structures of biomedical document collections. In addition, the proposed method is able to extract the key concepts and cluster the documents with a relatively high precision. Copyright 2010 Elsevier B.V. All rights reserved.
Minguet, Fernando; Salgado, Teresa M; van den Boogerd, Lucienne; Fernandez-Llimos, Fernando
2015-01-01
The Medical Subject Headings (MeSH) is the National Library of Medicine (NLM) controlled vocabulary for indexing articles. Inaccuracies in the MeSH thesaurus have been reported for several areas including pharmacy. To assess the quality of pharmacy-specific MeSH assignment to articles indexed in pharmacy journals. The 10 journals containing the highest number of articles published in 2012 indexed under the MeSH 'Pharmacists' were identified. All articles published over a 5-year period (2008-2012) in the 10 previously selected journals were retrieved from PubMed. MeSH terms used to index these articles were extracted and pharmacy-specific MeSH terms were identified. The frequency of use of pharmacy-specific MeSH terms was calculated across journals. A total of 6989 articles were retrieved from the 10 pharmacy journals, of which 328 (4.7%) were articles not fully indexed and therefore did not contain any MeSH terms assigned. Among the 6661 articles fully indexed, the mean number of MeSH terms was 10.1 (SD = 4.0), being 1.0 (SD = 1.3) considered as Major MeSH. Both values significantly varied across journals. The mean number of pharmacy-specific MeSH terms per article was 0.9 (SD = 1.2). A total of 3490 (52.4%) of the 6661 articles were indexed in pharmacy journals without a single pharmacy-specific MeSH. Of the total 67193 MeSH terms assigned to articles, on average 10.5% (SD = 13.9) were pharmacy-specific MeSH. A statistically significant different pattern of pharmacy-specific MeSH assignment was identified across journals (Kruskal-Wallis P < 0.001). The quality of assignment of the existing pharmacy-specific MeSH terms to articles indexed in pharmacy journals can be improved to further enhance evidence gathering in pharmacy. Over half of the articles published in the top-10 journals publishing pharmacy literature were indexed without a single pharmacy-specific MeSH. Copyright © 2015 Elsevier Inc. All rights reserved.
Gault, Lora V.; Shultz, Mary; Davies, Kathy J.
2002-01-01
Objectives: This study compared the mapping of natural language patron terms to the Medical Subject Headings (MeSH) across six MeSH interfaces for the MEDLINE database. Methods: Test data were obtained from search requests submitted by patrons to the Library of the Health Sciences, University of Illinois at Chicago, over a nine-month period. Search request statements were parsed into separate terms or phrases. Using print sources from the National Library of Medicine, Each parsed patron term was assigned corresponding MeSH terms. Each patron term was entered into each of the selected interfaces to determine how effectively they mapped to MeSH. Data were collected for mapping success, accessibility of MeSH term within mapped list, and total number of MeSH choices within each list. Results: The selected MEDLINE interfaces do not map the same patron term in the same way, nor do they consistently lead to what is considered the appropriate MeSH term. Conclusions: If searchers utilize the MEDLINE database to its fullest potential by mapping to MeSH, the results of the mapping will vary between interfaces. This variance may ultimately impact the search results. These differences should be considered when choosing a MEDLINE interface and when instructing end users. PMID:11999175
Gault, Lora V; Shultz, Mary; Davies, Kathy J
2002-04-01
This study compared the mapping of natural language patron terms to the Medical Subject Headings (MeSH) across six MeSH interfaces for the MEDLINE database. Test data were obtained from search requests submitted by patrons to the Library of the Health Sciences, University of Illinois at Chicago, over a nine-month period. Search request statements were parsed into separate terms or phrases. Using print sources from the National Library of Medicine, Each parsed patron term was assigned corresponding MeSH terms. Each patron term was entered into each of the selected interfaces to determine how effectively they mapped to MeSH. Data were collected for mapping success, accessibility of MeSH term within mapped list, and total number of MeSH choices within each list. The selected MEDLINE interfaces do not map the same patron term in the same way, nor do they consistently lead to what is considered the appropriate MeSH term. If searchers utilize the MEDLINE database to its fullest potential by mapping to MeSH, the results of the mapping will vary between interfaces. This variance may ultimately impact the search results. These differences should be considered when choosing a MEDLINE interface and when instructing end users.
Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology.
Fu, Tian-Ming; Hong, Guosong; Viveros, Robert D; Zhou, Tao; Lieber, Charles M
2017-11-21
Implantable electrical probes have led to advances in neuroscience, brain-machine interfaces, and treatment of neurological diseases, yet they remain limited in several key aspects. Ideally, an electrical probe should be capable of recording from large numbers of neurons across multiple local circuits and, importantly, allow stable tracking of the evolution of these neurons over the entire course of study. Silicon probes based on microfabrication can yield large-scale, high-density recording but face challenges of chronic gliosis and instability due to mechanical and structural mismatch with the brain. Ultraflexible mesh electronics, on the other hand, have demonstrated negligible chronic immune response and stable long-term brain monitoring at single-neuron level, although, to date, it has been limited to 16 channels. Here, we present a scalable scheme for highly multiplexed mesh electronics probes to bridge the gap between scalability and flexibility, where 32 to 128 channels per probe were implemented while the crucial brain-like structure and mechanics were maintained. Combining this mesh design with multisite injection, we demonstrate stable 128-channel local field potential and single-unit recordings from multiple brain regions in awake restrained mice over 4 mo. In addition, the newly integrated mesh is used to validate stable chronic recordings in freely behaving mice. This scalable scheme for mesh electronics together with demonstrated long-term stability represent important progress toward the realization of ideal implantable electrical probes allowing for mapping and tracking single-neuron level circuit changes associated with learning, aging, and neurodegenerative diseases. Copyright © 2017 the Author(s). Published by PNAS.
Ditzel, M; Deerenberg, E B; Grotenhuis, N; Harlaar, J J; Monkhorst, K; Bastiaansen-Jenniskens, Y M; Jeekel, J; Lange, J F
2013-10-01
In laparoscopic incisional hernia repair, direct contact between the prosthesis and the abdominal viscera is inevitable, which may lead to an inflammatory reaction resulting in abdominal adhesion formation. This study compared five different synthetic and biologic meshes in terms of adhesion formation, shrinkage, incorporation, and histologic characteristics after a period of 30 and 90 days. In 85 rats, a mesh was positioned intraperitoneally in direct contact with the viscera. Five different meshes were implanted: Prolene (polypropylene), Parietex composite (collagen-coated polyester), Strattice (porcine dermis, non-cross-linked), Surgisis (porcine small intestine submucosa, non-cross-linked), and Permacol (porcine dermis, cross-linked). The meshes were tested in terms of adhesion formation, shrinkage, and incorporation after a period of 30 and 90 days. Additionally, collagen formation after 90 days was determined. Significantly less adhesion formation was observed with Parietex composite (5 %; interquartile range [IQR], 2-5 %) and Strattice (5 %; IQR, 4-10 %) in the long term. In contrast, organs were attached to Permacol with four of seven meshes (57 %), and adhesion coverage of Surgisis mesh was present in 66 % (IQR, 0-100 %) of the cases. After 90 days, the best incorporation was seen with the Parietex composite mesh (79 %; IQR, 61-83 %). After 90 days, major alterations in adhesion formation were seen compared with 30 days. Histologically, Strattice and Parietex composite showed a new mesothelial layer on the visceral side of the mesh. Microscopic degradation and new collagen formation were seen in the Surgisis group. Parietex composite mesh demonstrated the best long-term results compared with all the other meshes. The biologic non-cross-linked mesh, Strattice, showed little adhesion formation and moderate shrinkage but poor incorporation. Biologic meshes are promising, but varying results require a more detailed investigation and demonstrate that biologic meshes are not necessarily superior to synthetic meshes. The significant changes that take place between 30 and 90 days should lead to careful interpretation of short-term experimental results.
NASA Astrophysics Data System (ADS)
Maljaars, Jakob M.; Labeur, Robert Jan; Möller, Matthias
2018-04-01
A generic particle-mesh method using a hybridized discontinuous Galerkin (HDG) framework is presented and validated for the solution of the incompressible Navier-Stokes equations. Building upon particle-in-cell concepts, the method is formulated in terms of an operator splitting technique in which Lagrangian particles are used to discretize an advection operator, and an Eulerian mesh-based HDG method is employed for the constitutive modeling to account for the inter-particle interactions. Key to the method is the variational framework provided by the HDG method. This allows to formulate the projections between the Lagrangian particle space and the Eulerian finite element space in terms of local (i.e. cellwise) ℓ2-projections efficiently. Furthermore, exploiting the HDG framework for solving the constitutive equations results in velocity fields which excellently approach the incompressibility constraint in a local sense. By advecting the particles through these velocity fields, the particle distribution remains uniform over time, obviating the need for additional quality control. The presented methodology allows for a straightforward extension to arbitrary-order spatial accuracy on general meshes. A range of numerical examples shows that optimal convergence rates are obtained in space and, given the particular time stepping strategy, second-order accuracy is obtained in time. The model capabilities are further demonstrated by presenting results for the flow over a backward facing step and for the flow around a cylinder.
Factor Analytic Approach to Transitive Text Mining using Medline Descriptors
NASA Astrophysics Data System (ADS)
Stegmann, J.; Grohmann, G.
Matrix decomposition methods were applied to examples of noninteractive literature sets sharing implicit relations. Document-by-term matrices were created from downloaded PubMed literature sets, the terms being the Medical Subject Headings (MeSH descriptors) assigned to the documents. The loadings of the factors derived from singular value or eigenvalue matrix decomposition were sorted according to absolute values and subsequently inspected for positions of terms relevant to the discovery of hidden connections. It was found that only a small number of factors had to be screened to find key terms in close neighbourhood, being separated by a small number of terms only.
Non-ideal magnetohydrodynamics on a moving mesh
NASA Astrophysics Data System (ADS)
Marinacci, Federico; Vogelsberger, Mark; Kannan, Rahul; Mocz, Philip; Pakmor, Rüdiger; Springel, Volker
2018-05-01
In certain astrophysical systems, the commonly employed ideal magnetohydrodynamics (MHD) approximation breaks down. Here, we introduce novel explicit and implicit numerical schemes of ohmic resistivity terms in the moving-mesh code AREPO. We include these non-ideal terms for two MHD techniques: the Powell 8-wave formalism and a constrained transport scheme, which evolves the cell-centred magnetic vector potential. We test our implementation against problems of increasing complexity, such as one- and two-dimensional diffusion problems, and the evolution of progressive and stationary Alfvén waves. On these test problems, our implementation recovers the analytic solutions to second-order accuracy. As first applications, we investigate the tearing instability in magnetized plasmas and the gravitational collapse of a rotating magnetized gas cloud. In both systems, resistivity plays a key role. In the former case, it allows for the development of the tearing instability through reconnection of the magnetic field lines. In the latter, the adopted (constant) value of ohmic resistivity has an impact on both the gas distribution around the emerging protostar and the mass loading of magnetically driven outflows. Our new non-ideal MHD implementation opens up the possibility to study magneto-hydrodynamical systems on a moving mesh beyond the ideal MHD approximation.
MeSH Now: automatic MeSH indexing at PubMed scale via learning to rank.
Mao, Yuqing; Lu, Zhiyong
2017-04-17
MeSH indexing is the task of assigning relevant MeSH terms based on a manual reading of scholarly publications by human indexers. The task is highly important for improving literature retrieval and many other scientific investigations in biomedical research. Unfortunately, given its manual nature, the process of MeSH indexing is both time-consuming (new articles are not immediately indexed until 2 or 3 months later) and costly (approximately ten dollars per article). In response, automatic indexing by computers has been previously proposed and attempted but remains challenging. In order to advance the state of the art in automatic MeSH indexing, a community-wide shared task called BioASQ was recently organized. We propose MeSH Now, an integrated approach that first uses multiple strategies to generate a combined list of candidate MeSH terms for a target article. Through a novel learning-to-rank framework, MeSH Now then ranks the list of candidate terms based on their relevance to the target article. Finally, MeSH Now selects the highest-ranked MeSH terms via a post-processing module. We assessed MeSH Now on two separate benchmarking datasets using traditional precision, recall and F 1 -score metrics. In both evaluations, MeSH Now consistently achieved over 0.60 in F-score, ranging from 0.610 to 0.612. Furthermore, additional experiments show that MeSH Now can be optimized by parallel computing in order to process MEDLINE documents on a large scale. We conclude that MeSH Now is a robust approach with state-of-the-art performance for automatic MeSH indexing and that MeSH Now is capable of processing PubMed scale documents within a reasonable time frame. http://www.ncbi.nlm.nih.gov/CBBresearch/Lu/Demo/MeSHNow/ .
Shultz, Mary
2006-01-01
Introduction: Given the common use of acronyms and initialisms in the health sciences, searchers may be entering these abbreviated terms rather than full phrases when searching online systems. The purpose of this study is to evaluate how various MEDLINE Medical Subject Headings (MeSH) interfaces map acronyms and initialisms to the MeSH vocabulary. Methods: The interfaces used in this study were: the PubMed MeSH database, the PubMed Automatic Term Mapping feature, the NLM Gateway Term Finder, and Ovid MEDLINE. Acronyms and initialisms were randomly selected from 2 print sources. The test data set included 415 randomly selected acronyms and initialisms whose related meanings were found to be MeSH terms. Each acronym and initialism was entered into each MEDLINE MeSH interface to determine if it mapped to the corresponding MeSH term. Separately, 46 commonly used acronyms and initialisms were tested. Results: While performance differed widely, the success rates were low across all interfaces for the randomly selected terms. The common acronyms and initialisms tested at higher success rates across the interfaces, but the differences between the interfaces remained. Conclusion: Online interfaces do not always map medical acronyms and initialisms to their corresponding MeSH phrases. This may lead to inaccurate results and missed information if acronyms and initialisms are used in search strategies. PMID:17082832
Martinho-Dias, Daniel; Sousa-Pinto, Bernardo; Botelho-Souza, Júlio; Soares, António; Delgado, Luís; Fonseca, João Almeida
2018-01-01
We performed a MeSH term-based bibliometric analysis aiming to assess the publication trends of EAACI journals, namely Allergy, Pediatric Allergy and Immunology (PAI) (from 1990 to 2015) and Clinical and Translational Allergy (CTA) (from its inception in 2011 to 2015). We also aimed to discuss the impact of the creation of CTA in the publication topics of Allergy and PAI. We analysed a total of 1973 articles and 23,660 MeSH terms. Most MeSH terms in the three journals fell in the category of "basic immunology and molecular biology" (BIMB). During the studied period, we observed an increase in the proportion of MeSH terms on BIMB, and a decreasing proportion of terms on allergic rhinitis and aeroallergens. The observed changes in Allergy and PAI publication topics hint at a possible impact from CTA creation.
A short note on the use of the red-black tree in Cartesian adaptive mesh refinement algorithms
NASA Astrophysics Data System (ADS)
Hasbestan, Jaber J.; Senocak, Inanc
2017-12-01
Mesh adaptivity is an indispensable capability to tackle multiphysics problems with large disparity in time and length scales. With the availability of powerful supercomputers, there is a pressing need to extend time-proven computational techniques to extreme-scale problems. Cartesian adaptive mesh refinement (AMR) is one such method that enables simulation of multiscale, multiphysics problems. AMR is based on construction of octrees. Originally, an explicit tree data structure was used to generate and manipulate an adaptive Cartesian mesh. At least eight pointers are required in an explicit approach to construct an octree. Parent-child relationships are then used to traverse the tree. An explicit octree, however, is expensive in terms of memory usage and the time it takes to traverse the tree to access a specific node. For these reasons, implicit pointerless methods have been pioneered within the computer graphics community, motivated by applications requiring interactivity and realistic three dimensional visualization. Lewiner et al. [1] provides a concise review of pointerless approaches to generate an octree. Use of a hash table and Z-order curve are two key concepts in pointerless methods that we briefly discuss next.
Wang, Xinheng
2008-01-01
Wireless telemedicine using GSM and GPRS technologies can only provide low bandwidth connections, which makes it difficult to transmit images and video. Satellite or 3G wireless transmission provides greater bandwidth, but the running costs are high. Wireless networks (WLANs) appear promising, since they can supply high bandwidth at low cost. However, the WLAN technology has limitations, such as coverage. A new wireless networking technology named the wireless mesh network (WMN) overcomes some of the limitations of the WLAN. A WMN combines the characteristics of both a WLAN and ad hoc networks, thus forming an intelligent, large scale and broadband wireless network. These features are attractive for telemedicine and telecare because of the ability to provide data, voice and video communications over a large area. One successful wireless telemedicine project which uses wireless mesh technology is the Emergency Room Link (ER-LINK) in Tucson, Arizona, USA. There are three key characteristics of a WMN: self-organization, including self-management and self-healing; dynamic changes in network topology; and scalability. What we may now see is a shift from mobile communication and satellite systems for wireless telemedicine to the use of wireless networks based on mesh technology, since the latter are very attractive in terms of cost, reliability and speed.
An Interpreted Language and System for the Visualization of Unstructured Meshes
NASA Technical Reports Server (NTRS)
Moran, Patrick J.; Gerald-Yamasaki, Michael (Technical Monitor)
1998-01-01
We present an interpreted language and system supporting the visualization of unstructured meshes and the manipulation of shapes defined in terms of mesh subsets. The language features primitives inspired by geometric modeling, mathematical morphology and algebraic topology. The adaptation of the topology ideas to an interpreted environment, along with support for programming constructs such, as user function definition, provide a flexible system for analyzing a mesh and for calculating with shapes defined in terms of the mesh. We present results demonstrating some of the capabilities of the language, based on an implementation called the Shape Calculator, for tetrahedral meshes in R^3.
Characterization of the mechanism of drug-drug interactions from PubMed using MeSH terms.
Lu, Yin; Figler, Bryan; Huang, Hong; Tu, Yi-Cheng; Wang, Ju; Cheng, Feng
2017-01-01
Identifying drug-drug interaction (DDI) is an important topic for the development of safe pharmaceutical drugs and for the optimization of multidrug regimens for complex diseases such as cancer and HIV. There have been about 150,000 publications on DDIs in PubMed, which is a great resource for DDI studies. In this paper, we introduced an automatic computational method for the systematic analysis of the mechanism of DDIs using MeSH (Medical Subject Headings) terms from PubMed literature. MeSH term is a controlled vocabulary thesaurus developed by the National Library of Medicine for indexing and annotating articles. Our method can effectively identify DDI-relevant MeSH terms such as drugs, proteins and phenomena with high accuracy. The connections among these MeSH terms were investigated by using co-occurrence heatmaps and social network analysis. Our approach can be used to visualize relationships of DDI terms, which has the potential to help users better understand DDIs. As the volume of PubMed records increases, our method for automatic analysis of DDIs from the PubMed database will become more accurate.
Bekhuis, Tanja; Demner-Fushman, Dina; Crowley, Rebecca S.
2013-01-01
Objectives: We analyzed the extent to which comparative effectiveness research (CER) organizations share terms for designs, analyzed coverage of CER designs in Medical Subject Headings (MeSH) and Emtree, and explored whether scientists use CER design terms. Methods: We developed local terminologies (LTs) and a CER design terminology by extracting terms in documents from five organizations. We defined coverage as the distribution over match type in MeSH and Emtree. We created a crosswalk by recording terms to which design terms mapped in both controlled vocabularies. We analyzed the hits for queries restricted to titles and abstracts to explore scientists' language. Results: Pairwise LT overlap ranged from 22.64% (12/53) to 75.61% (31/41). The CER design terminology (n = 78 terms) consisted of terms for primary study designs and a few terms useful for evaluating evidence, such as opinion paper and systematic review. Patterns of coverage were similar in MeSH and Emtree (gamma = 0.581, P = 0.002). Conclusions: Stakeholder terminologies vary, and terms are inconsistently covered in MeSH and Emtree. The CER design terminology and crosswalk may be useful for expert searchers. For partially mapped terms, queries could consist of free text for modifiers such as nonrandomized or interrupted added to broad or related controlled terms. PMID:23646024
Pascual, Gemma; Hernández-Gascón, Belén; Rodríguez, Marta; Sotomayor, Sandra; Peña, Estefania; Calvo, Begoña; Bellón, Juan M
2012-11-01
Although heavyweight (HW) or lightweight (LW) polypropylene (PP) meshes are widely used for hernia repair, other alternatives have recently appeared. They have the same large-pore structure yet are composed of polytetrafluoroethylene (PTFE). This study compares the long-term (3 and 6 months) behavior of meshes of different pore size (HW compared with LW) and composition (PP compared with PTFE). Partial defects were created in the lateral wall of the abdomen in New Zealand White rabbits and then repaired by the use of a HW or LW PP mesh or a new monofilament, large-pore PTFE mesh (Infinit). At 90 and 180 days after implantation, tissue incorporation, gene and protein expression of neocollagens (reverse transcription-polymerase chain reaction/immunofluorescence), macrophage response (immunohistochemistry), and biomechanical strength were determined. Shrinkage was measured at 90 days. All three meshes induced good host tissue ingrowth, yet the macrophage response was significantly greater in the PTFE implants (P < .05). Collagen 1/3 mRNA levels failed to vary at 90 days yet in the longer term, the LW meshes showed the reduced genetic expression of both collagens (P < .05) accompanied by increased neocollagen deposition, indicating more efficient mRNA translation. After 90-180 days of implant, tensile strengths and elastic modulus values were similar for all 3 implants (P > .05). Host collagen deposition is mesh pore size dependent whereas the macrophage response induced is composition dependent with a greater response shown by PTFE. In the long term, macroporous meshes show comparable biomechanical behavior regardless of their pore size or composition. Copyright © 2012 Mosby, Inc. All rights reserved.
Update on Development of Mesh Generation Algorithms in MeshKit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Rajeev; Vanderzee, Evan; Mahadevan, Vijay
2015-09-30
MeshKit uses a graph-based design for coding all its meshing algorithms, which includes the Reactor Geometry (and mesh) Generation (RGG) algorithms. This report highlights the developmental updates of all the algorithms, results and future work. Parallel versions of algorithms, documentation and performance results are reported. RGG GUI design was updated to incorporate new features requested by the users; boundary layer generation and parallel RGG support were added to the GUI. Key contributions to the release, upgrade and maintenance of other SIGMA1 libraries (CGM and MOAB) were made. Several fundamental meshing algorithms for creating a robust parallel meshing pipeline in MeshKitmore » are under development. Results and current status of automated, open-source and high quality nuclear reactor assembly mesh generation algorithms such as trimesher, quadmesher, interval matching and multi-sweeper are reported.« less
Surgical mesh for ventral incisional hernia repairs: Understanding mesh design
Rastegarpour, Ali; Cheung, Michael; Vardhan, Madhurima; Ibrahim, Mohamed M; Butler, Charles E; Levinson, Howard
2016-01-01
Surgical mesh has become an indispensable tool in hernia repair to improve outcomes and reduce costs; however, efforts are constantly being undertaken in mesh development to overcome postoperative complications. Common complications include infection, pain, adhesions, mesh extrusion and hernia recurrence. Reducing the complications of mesh implantation is of utmost importance given that hernias occur in hundreds of thousands of patients per year in the United States. In the present review, the authors present the different types of hernia meshes, discuss the key properties of mesh design, and demonstrate how each design element affects performance and complications. The present article will provide a basis for surgeons to understand which mesh to choose for patient care and why, and will explain the important technological aspects that will continue to evolve over the ensuing years. PMID:27054138
Improved ALE mesh velocities for complex flows
Bakosi, Jozsef; Waltz, Jacob I.; Morgan, Nathaniel Ray
2017-05-31
A key choice in the development of arbitrary Lagrangian-Eulerian solution algorithms is how to move the computational mesh. The most common approaches are smoothing and relaxation techniques, or to compute a mesh velocity field that produces smooth mesh displacements. We present a method in which the mesh velocity is specified by the irrotational component of the fluid velocity as computed from a Helmholtz decomposition, and excess compression of mesh cells is treated through a noniterative, local spring-force model. This approach allows distinct and separate control over rotational and translational modes. In conclusion, the utility of the new mesh motion algorithmmore » is demonstrated on a number of 3D test problems, including problems that involve both shocks and significant amounts of vorticity.« less
Bindi, Marco; Rivelli, Matteo; Solej, Mario; Enrico, Stefano; Martino, Valter
2016-01-01
Abstract Laparoscopic transabdominal preperitoneal inguinal hernia repair is a safe and effective technique. In this study we tested the hypothesis that self-gripping mesh used with the laparoscopic approach is comparable to polypropylene mesh in terms of perioperative complications, against a lower overall cost of the procedure. We carried out a prospective randomized trial comparing a group of 30 patients who underwent laparoscopic inguinal hernia repair with self-gripping mesh versus a group of 30 patients who received polypropylene mesh with fibrin glue fixation. There were no statistically significant differences between the two groups with regard to intraoperative variables, early or late intraoperative complications, chronic pain or recurrence. Self-gripping mesh in transabdominal hernia repair was found to be a valid alternative to polypropylene mesh in terms of complications, recurrence and postoperative pain. The cost analysis and comparability of outcomes support the preferential use of self-gripping mesh. PMID:28352842
Mesh Nanoelectronics: Seamless Integration of Electronics with Tissues.
Dai, Xiaochuan; Hong, Guosong; Gao, Teng; Lieber, Charles M
2018-02-20
Nanobioelectronics represents a rapidly developing field with broad-ranging opportunities in fundamental biological sciences, biotechnology, and medicine. Despite this potential, seamless integration of electronics has been difficult due to fundamental mismatches, including size and mechanical properties, between the elements of the electronic and living biological systems. In this Account, we discuss the concept, development, key demonstrations, and future opportunities of mesh nanoelectronics as a general paradigm for seamless integration of electronics within synthetic tissues and live animals. We first describe the design and realization of hybrid synthetic tissues that are innervated in three dimensions (3D) with mesh nanoelectronics where the mesh serves as both as a tissue scaffold and as a platform of addressable electronic devices for monitoring and manipulating tissue behavior. Specific examples of tissue/nanoelectronic mesh hybrids highlighted include 3D neural tissue, cardiac patches, and vascular constructs, where the nanoelectronic devices have been used to carry out real-time 3D recording of electrophysiological and chemical signals in the tissues. This novel platform was also exploited for time-dependent 3D spatiotemporal mapping of cardiac tissue action potentials during cell culture and tissue maturation as well as in response to injection of pharmacological agents. The extension to simultaneous real-time monitoring and active control of tissue behavior is further discussed for multifunctional mesh nanoelectronics incorporating both recording and stimulation devices, providing the unique capability of bidirectional interfaces to cardiac tissue. In the case of live animals, new challenges must be addressed, including minimally invasive implantation, absence of deleterious chronic tissue response, and long-term capability for monitoring and modulating tissue activity. We discuss each of these topics in the context of implantation of mesh nanoelectronics into rodent brains. First, we describe the design of ultraflexible mesh nanoelectronics with size features and mechanical properties similar to brain tissue and a novel syringe-injection methodology that allows the mesh nanoelectronics to be precisely delivered to targeted brain regions in a minimally invasive manner. Next, we discuss time-dependent histology studies showing seamless and stable integration of mesh nanoelectronics within brain tissue on at least one year scales without evidence of chronic immune response or glial scarring characteristic of conventional implants. Third, armed with facile input/output interfaces, we describe multiplexed single-unit recordings that demonstrate stable tracking of the same individual neurons and local neural circuits for at least 8 months, long-term monitoring and stimulation of the same groups of neurons, and following changes in individual neuron activity during brain aging. Moving forward, we foresee substantial opportunities for (1) continued development of mesh nanoelectronics through, for example, broadening nanodevice signal detection modalities and taking advantage of tissue-like properties for selective cell targeting and (2) exploiting the unique capabilities of mesh nanoelectronics for tackling critical scientific and medical challenges such as understanding and potentially ameliorating cell and circuit level changes associated with natural and pathological aging, as well as using mesh nanoelectronics as active tissue scaffolds for regenerative medicine and as neuroprosthetics for monitoring and treating neurological diseases.
NASA Technical Reports Server (NTRS)
DeCristofaro, Michael A.; Lansdowne, Chatwin A.; Schlesinger, Adam M.
2014-01-01
NASA has identified standardized wireless mesh networking as a key technology for future human and robotic space exploration. Wireless mesh networks enable rapid deployment, provide coverage in undeveloped regions. Mesh networks are also self-healing, resilient, and extensible, qualities not found in traditional infrastructure-based networks. Mesh networks can offer lower size, weight, and power (SWaP) than overlapped infrastructure-perapplication. To better understand the maturity, characteristics and capability of the technology, we developed an 802.11 mesh network consisting of a combination of heterogeneous commercial off-the-shelf devices and opensource firmware and software packages. Various streaming applications were operated over the mesh network, including voice and video, and performance measurements were made under different operating scenarios. During the testing several issues with the currently implemented mesh network technology were identified and outlined for future work.
Tissue-like Neural Probes for Understanding and Modulating the Brain.
Hong, Guosong; Viveros, Robert D; Zwang, Theodore J; Yang, Xiao; Lieber, Charles M
2018-03-19
Electrophysiology tools have contributed substantially to understanding brain function, yet the capabilities of conventional electrophysiology probes have remained limited in key ways because of large structural and mechanical mismatches with respect to neural tissue. In this Perspective, we discuss how the general goal of probe design in biochemistry, that the probe or label have a minimal impact on the properties and function of the system being studied, can be realized by minimizing structural, mechanical, and topological differences between neural probes and brain tissue, thus leading to a new paradigm of tissue-like mesh electronics. The unique properties and capabilities of the tissue-like mesh electronics as well as future opportunities are summarized. First, we discuss the design of an ultraflexible and open mesh structure of electronics that is tissue-like and can be delivered in the brain via minimally invasive syringe injection like molecular and macromolecular pharmaceuticals. Second, we describe the unprecedented tissue healing without chronic immune response that leads to seamless three-dimensional integration with a natural distribution of neurons and other key cells through these tissue-like probes. These unique characteristics lead to unmatched stable long-term, multiplexed mapping and modulation of neural circuits at the single-neuron level on a year time scale. Last, we offer insights on several exciting future directions for the tissue-like electronics paradigm that capitalize on their unique properties to explore biochemical interactions and signaling in a "natural" brain environment.
Theodosiou, T; Vizirianakis, I S; Angelis, L; Tsaftaris, A; Darzentas, N
2011-12-01
PubMed is the most widely used database of biomedical literature. To the detriment of the user though, the ranking of the documents retrieved for a query is not content-based, and important semantic information in the form of assigned Medical Subject Headings (MeSH) terms is not readily presented or productively utilized. The motivation behind this work was the discovery of unanticipated information through the appropriate ranking of MeSH term pairs and, indirectly, documents. Such information can be useful in guiding novel research and following promising trends. A web-based tool, called MeSHy, was developed implementing a mainly statistical algorithm. The algorithm takes into account the frequencies of occurrences, concurrences, and the semantic similarities of MeSH terms in retrieved PubMed documents to create MeSH term pairs. These are then scored and ranked, focusing on their unexpectedly frequent or infrequent occurrences. MeSHy presents results through an online interactive interface facilitating further manipulation through filtering and sorting. The results themselves include the MeSH term pairs, along with MeSH categories, the score, and document IDs, all of which are hyperlinked for convenience. To highlight the applicability of the tool, we report the findings of an expert in the pharmacology field on querying the molecularly-targeted drug imatinib and nutrition-related flavonoids. To the best of our knowledge, MeSHy is the first publicly available tool able to directly provide such a different perspective on the complex nature of published work. Implemented in Perl and served by Apache2 at http://bat.ina.certh.gr/tools/meshy/ with all major browsers supported. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Salinas, P.; Pavlidis, D.; Jacquemyn, C.; Lei, Q.; Xie, Z.; Pain, C.; Jackson, M.
2017-12-01
It is well known that the pressure gradient into a production well increases with decreasing distance to the well. To properly capture the local pressure drawdown into the well a high grid or mesh resolution is required; moreover, the location of the well must be captured accurately. In conventional simulation models, the user must interact with the model to modify grid resolution around wells of interest, and the well location is approximated on a grid defined early in the modelling process.We report a new approach for improved simulation of near wellbore flow in reservoir scale models through the use of dynamic mesh optimisation and the recently presented double control volume finite element method. Time is discretized using an adaptive, implicit approach. Heterogeneous geologic features are represented as volumes bounded by surfaces. Within these volumes, termed geologic domains, the material properties are constant. Up-, cross- or down-scaling of material properties during dynamic mesh optimization is not required, as the properties are uniform within each geologic domain. A given model typically contains numerous such geologic domains. Wells are implicitly coupled with the domain, and the fluid flows is modelled inside the wells. The method is novel for two reasons. First, a fully unstructured tetrahedral mesh is used to discretize space, and the spatial location of the well is specified via a line vector, ensuring its location even if the mesh is modified during the simulation. The well location is therefore accurately captured, the approach allows complex well trajectories and wells with many laterals to be modelled. Second, computational efficiency is increased by use of dynamic mesh optimization, in which an unstructured mesh adapts in space and time to key solution fields (preserving the geometry of the geologic domains), such as pressure, velocity or temperature, this also increases the quality of the solutions by placing higher resolution where required to reduce an error metric based on the Hessian of the field. This allows the local pressure drawdown to be captured without user¬ driven modification of the mesh. We demonstrate that the method has wide application in reservoir ¬scale models of geothermal fields, and regional models of groundwater resources.
Pedano, Nicolás; Pastor, Carlos; Arredondo, Jorge; Poveda, Ignacio; Ruiz, Jaime; Montón, Soledad; Molina, María; Hernández-Lizoain, José Luis
2012-02-01
The process of mesh fixation and the potential risk of associated chronic pain are always surgeon's main concerns in hernia surgery. A wide variety of lightweight mesh models are currently available on the market to overcome some of these problems showing good preliminary results, but no data representing the medium- or long-term results. The present study aims to report the clinical outcomes of two institutional series of patients who underwent hernia repair using a partially absorbable auto adherent mesh (Parietene™ Progrip™--PP). A prospective analysis was performed including unselected patients with primary groin hernia who underwent a standardized Lichtenstein procedure using the PP mesh at two tertiary institutions. During the 2-year study period, 181 patients (167 males; 14 females) with a median age of 63 years (19-85 years) were operated on at both centers. Short-term complications occurred in 27 patients (15%), the most commonly seen being urinary retention (6%) followed by hematoma (5%) and acute orchitis (2%). With a median follow-up of 17 months (12-29 months), 4 patients (2%) had a feeling of a foreign body in the groin, and 7 (4%) developed chronic pain. A total of four patients (2%) developed recurrence. In our experience, the use of the PP mesh for hernioplasties offers a potential benefit not only in the short-term period but also in a medium-term follow-up with low recurrence and late chronic pain rates. However, this particular mesh does not fully prevent all complications and chronic pain and recurrent hernias have been reported for the first time.
Su, Yan; Andrews, James; Huang, Hong; Wang, Yue; Kong, Liangliang; Cannon, Peter; Xu, Ping
2016-05-23
PubMed is a widely used database for scientists to find biomedical-related literature. Due to the complexity of the selected research subject and its interdisciplinary nature, as well as the exponential growth in the number of disparate pieces of biomedical literature, it is an overwhelming challenge for scientists to define the right search strategies and quickly locate all related information. Specialized subsets and groupings of controlled vocabularies, such as Medical Subject Headings (MeSH), can enhance information retrieval in specialized domains, such as stem cell research. There is a need to develop effective search strategies and convenient solutions for knowledge organization in stem cell research. The understanding of the interrelationships between these MeSH terms also facilitates the building of knowledge organization systems in related subject fields. This study collected empirical data for MeSH-related terms from stem cell literature and developed a novel approach that uses both automation and expert-selection to create a set of terms that supports enhanced retrieval. The selected MeSH terms were reconstructed into a classified thesaurus that can guide researchers towards a successful search and knowledge organization of stem cell literature. First, 4253 MeSH terms were harvested from a sample of 5527 stem cell related research papers from the PubMed database. Next, unrelated terms were filtered out based on term frequency and specificity. Precision and recall measures were used to help identify additional valuable terms, which were mostly non-MeSH terms. The study identified 15 terms that specifically referred to stem cell research for information retrieval, which would yield a higher precision (97.7 %) and recall (94.4 %) rates in comparison to other approaches. In addition, 128 root MeSH terms were selected to conduct knowledge organization of stem cell research in categories of anatomy, disease, and others. This study presented a novel strategy and procedure to reengineer term selections of the MeSH thesaurus for literature retrieval and knowledge organization using stem cell research as a case. It could help scientists to select their own search terms and build up a thesaurus-based knowledge organization system in interested and interdisciplinary research subject areas.
Developing Creative and Critical Thinkers
2009-12-01
competitive advantage and long-term success. Strategic thinking meshes anticipated requirements with future organizational capabilities to ensure the organization wins in the future. Examples of failures in strategic thinking abound. They include the recent failures of U.S. auto companies to understand the key factors facing their industry. Of greater significance is our own failure of strategic thinking in the formulation and acceptance of the many pre-war assumptions about Iraq. The core elements of strategic thinking are the ability to think creatively and critically
NASA Technical Reports Server (NTRS)
Wey, Thomas; Liu, Nan-Suey
2015-01-01
This paper summarizes the procedures of (1) generating control volumes anchored at the nodes of a mesh; and (2) generating staggered control volumes via mesh reconstructions, in terms of either mesh realignment or mesh refinement, as well as presents sample results from their applications to the numerical solution of a single-element LDI combustor using a releasable edition of the National Combustion Code (NCC).
A promising new device for the prevention of parastomal hernia.
Hoffmann, Henry; Oertli, Daniel; Soysal, Savas; Zingg, Urs; Hahnloser, Dieter; Kirchhoff, Philipp
2015-06-01
Parastomal hernia (PSH) is the most frequent long-term stoma complication with serious negative effects on quality of life. Surgical revision is often required and has a substantial morbidity and recurrence rate. The development of PSH requires revisional surgery with a substantial perioperative morbidity and high failure rate in the long-term follow-up. Prophylactic parastomal mesh insertion during stoma creation has the potential to reduce the rate of PSH, but carries the risk of early and late mesh-related complications such as infection, fibrosis, mesh shrinkage, and/or bowel erosion. We developed a new stomaplasty ring (KORING), which is easy to implant, avoids potential mesh-related complications, and has a high potential of long-term prevention of PSH. Here we describe the technique and the first use. © The Author(s) 2014.
Issa, Nidal; Ohana, Gil; Bachar, Gil Nissim; Powsner, Eldad
2016-02-01
A totally extraperitoneal (TEP) approach is currently the technique of choice for the laparoscopic repair of bilateral inguinal hernias in our institution. Most other surgeons use two meshes for the TEP repair, one for each side. We prefer a large single mesh when possible since it allows for easier correct placement of the mesh in one stage. We compared our long-term results of both techniques in terms of late complications and recurrence rates. This study retrospectively evaluated the medical records of 108 patients who underwent bilateral laparoscopic TEP repair in our institution between January 2002 and December 2003. Excluded were patients who had a conversion to a transabdominal preperitoneal or open approach. A total of 73 (67 %) patients fulfilled study entrance criteria and were enrolled: 39 had undergone single mesh repair and 34 had undergone double mesh repair. There were no significant group differences in demographics, operating time, postoperative morbidity, or hospital stay. Likewise, after a median follow-up of 102 months (range 94–115 months), there were no significant group differences between the single and double mesh groups in persistent pain (5.8 vs 2.5 %, respectively; p = 0.476) and recurrence (7.6 vs 8.8 %, respectively; p = 0.55). The use of a large single mesh is an effective and safe alternative technique for TEP repair of bilateral inguinal hernias, and is technically easy to perform.
Meta-analysis of Prolene Hernia System mesh versus Lichtenstein mesh in open inguinal hernia repair.
Sanjay, Pandanaboyana; Watt, David G; Ogston, Simon A; Alijani, Afshin; Windsor, John A
2012-10-01
This study was designed to systematically analyse all published randomized clinical trials comparing the Prolene Hernia System (PHS) mesh and Lichtenstein mesh for open inguinal hernia repair. A literature search was performed using the Cochrane Colorectal Cancer Group Controlled Trials Register, the Cochrane Central Register of Controlled Trials in the Cochrane Library, MEDLINE, Embase and Science Citation Index Expanded. Randomized trials comparing the Lichtenstein Mesh repair (LMR) with the Prolene Hernia System were included. Statistical analysis was performed using Review Manager Version 5.1 software. The primary outcome measures were hernia recurrence and chronic pain after operation. Secondary outcome measures included surgical time, peri-operative complications, time to return to work, early and long-term postoperative complications. Six randomized clinical trials were identified as suitable, containing 1313 patients. There was no statistical difference between the two types of repair in operation time, time to return to work, incidence of chronic groin pain, hernia recurrence or long-term complications. The PHS group had a higher rate of peri-operative complications, compared to Lichtenstein mesh repair (risk ratio (RR) 0.71, 95% confidence interval 0.55-0.93, P=0.01). The use of PHS mesh was associated with an increased risk of peri-operative complications compared to LMR. Both mesh repair techniques have comparable short- and long-term outcomes. Copyright © 2012 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.
An adaptive mesh-moving and refinement procedure for one-dimensional conservation laws
NASA Technical Reports Server (NTRS)
Biswas, Rupak; Flaherty, Joseph E.; Arney, David C.
1993-01-01
We examine the performance of an adaptive mesh-moving and /or local mesh refinement procedure for the finite difference solution of one-dimensional hyperbolic systems of conservation laws. Adaptive motion of a base mesh is designed to isolate spatially distinct phenomena, and recursive local refinement of the time step and cells of the stationary or moving base mesh is performed in regions where a refinement indicator exceeds a prescribed tolerance. These adaptive procedures are incorporated into a computer code that includes a MacCormack finite difference scheme wih Davis' artificial viscosity model and a discretization error estimate based on Richardson's extrapolation. Experiments are conducted on three problems in order to qualify the advantages of adaptive techniques relative to uniform mesh computations and the relative benefits of mesh moving and refinement. Key results indicate that local mesh refinement, with and without mesh moving, can provide reliable solutions at much lower computational cost than possible on uniform meshes; that mesh motion can be used to improve the results of uniform mesh solutions for a modest computational effort; that the cost of managing the tree data structure associated with refinement is small; and that a combination of mesh motion and refinement reliably produces solutions for the least cost per unit accuracy.
Damarell, Raechel A; Tieman, Jennifer J; Sladek, Ruth M
2013-07-02
PubMed translations of OvidSP Medline search filters offer searchers improved ease of access. They may also facilitate access to PubMed's unique content, including citations for the most recently published biomedical evidence. Retrieving this content requires a search strategy comprising natural language terms ('textwords'), rather than Medical Subject Headings (MeSH). We describe a reproducible methodology that uses a validated PubMed search filter translation to create a textword-only strategy to extend retrieval to PubMed's unique heart failure literature. We translated an OvidSP Medline heart failure search filter for PubMed and established version equivalence in terms of indexed literature retrieval. The PubMed version was then run within PubMed to identify citations retrieved by the filter's MeSH terms (Heart failure, Left ventricular dysfunction, and Cardiomyopathy). It was then rerun with the same MeSH terms restricted to searching on title and abstract fields (i.e. as 'textwords'). Citations retrieved by the MeSH search but not the textword search were isolated. Frequency analysis of their titles/abstracts identified natural language alternatives for those MeSH terms that performed less effectively as textwords. These terms were tested in combination to determine the best performing search string for reclaiming this 'lost set'. This string, restricted to searching on PubMed's unique content, was then combined with the validated PubMed translation to extend the filter's performance in this database. The PubMed heart failure filter retrieved 6829 citations. Of these, 834 (12%) failed to be retrieved when MeSH terms were converted to textwords. Frequency analysis of the 834 citations identified five high frequency natural language alternatives that could improve retrieval of this set (cardiac failure, cardiac resynchronization, left ventricular systolic dysfunction, left ventricular diastolic dysfunction, and LV dysfunction). Together these terms reclaimed 157/834 (18.8%) of lost citations. MeSH terms facilitate precise searching in PubMed's indexed subset. They may, however, work less effectively as search terms prior to subject indexing. A validated PubMed search filter can be used to develop a supplementary textword-only search strategy to extend retrieval to PubMed's unique content. A PubMed heart failure search filter is available on the CareSearch website (http://www.caresearch.com.au) providing access to both indexed and non-indexed heart failure evidence.
Mesh for prolapse surgery: Why the fuss?
Rajshekhar, Smita; Mukhopadhyay, Sambit; Klinge, Uwe
2015-06-01
Pelvic organ prolapse is a common gynaecological problem. Surgical techniques to repair prolapse have been constantly evolving to reduce the recurrence of prolapse and need for reoperation. Grafts made of synthetic and biological materials became popular in the last decade as they were intended to provide extra support to native tissue repairs. However, serious complications related to use of synthetic meshes have been reported and there is increasing medico-legal concern about mesh use in prolapse surgery. Some mesh products already have been withdrawn from the market and the FDA has introduced stricter surveillance of new and existing products. Large randomized studies comparing mesh with non-mesh procedures are lacking which creates uncertainty for the surgeon and their patients.The small cohorts of the RCTs available with short follow-up periods just allow the conclusion that the mesh repair can be helpful in the short to medium term but unfortunately are not able to prove safety for all patients. In particular, current clinical reports cannot define for which indication what material may be superior compared to non-mesh repair.Quality control through long-term individual and national mesh registries is needed to keep a record of all surgeons using mesh and all devices being used, monitoring their effectiveness and safety data. Meshes with better biocompatibility designed specifically for use in vaginal surgery may provide superior clinical results, where the reduction of complications may allow a wider range of indications. © The Author(s) 2015.
Tissue response to collagen containing polypropylene meshes in an ovine vaginal repair model.
Darzi, Saeedeh; Urbankova, Iva; Su, Kai; White, Jacinta; Lo, Camden; Alexander, David; Werkmeister, Jerome A; Gargett, Caroline E; Deprest, Jan
2016-07-15
Pelvic Organ Prolapse (POP) is the herniation of pelvic organs into the vagina. Despite broad acceptance of mesh use in POP surgical repair, the complication rate is unacceptable. We hypothesized that collagen-containing polypropylene (PP) mesh types could modulate mesh-tissue integration and reduce long-term inflammation, thereby reducing mesh-associated complications. This study compared the long-term tissue response to an unmodified PP mesh and two collagen containing meshes in an ovine model which has similar pelvic anatomy and vaginal size to human. Three commercially available macroporous PP meshes, uncoated PP mesh (Avaulta Solo) (PP), the same textile PP mesh layered with a sheet of cross-linked porcine acellular matrix (Avaulta Plus) (PP-ACM) and a different yet also macroporous PP (Sofradim) mesh coated with solubilized atelocollagen (Ugytex) (PP-sCOL) were implanted in the ovine vagina and tissue explanted after 60 and 180days. The macrophage phenotype and response to implanted meshes, and vascularity were quantified by immunostaining and morphometry. We quantified changes in extracellular matrix composition biochemically and collagen organisation and percentage area around the interface of the mesh implants by Sirius Red birefringence and morphometry. PP-ACM induced a more sustained inflammatory response, indicated by similar CD45(+) leukocytes but reduced CD163(+) M2 macrophages at 60days (P<0.05). PP-sCOL increased Von Willebrand Factor (vWF)-immunoreactive vessel profiles after 60days. At the micro-molecular level, collagen birefringence quantification revealed significantly fewer mature collagen fibrils (red, thick fibrils) at the mesh-tissue interface than control tissue for all mesh types (P<0.001) but still significantly greater than the proportion of immature (green thin fibrils) at 60days (P<0.05). The proportion of mature collagen fibrils increased with time around the mesh filaments, particularly those containing collagen. The total collagen percent area at the mesh interface was greatest around the PP-ACM mesh at 60days (P<0.05). By 180days the total mature and immature collagen fibres at the interface of the mesh filaments resembled that of native tissue. In particular, these results suggest that both meshes containing collagen evoke different types of tissue responses at different times during the healing response yet both ultimately lead to physiological tissue formation approaching that of normal tissue. Pelvic organ prolapse (POP) is the descent of the pelvic organs to the vagina. POP affects more than 25% of all women and the lifetime risk of undergoing POP surgery is 19%. Although synthetic polypropylene (PP) meshes have improved the outcome of the surgical treatment for POP, there was an unacceptable rate of adverse events including mesh exposure and contracture. It is hypothesized that coating the PP meshes with collagen would provide a protective effect by preventing severe mesh adhesions to the wound, resulting in a better controlled initial inflammatory response, and diminished risk of exposure. In this study we assessed the effect of two collagen-containing PP meshes on the long-term vaginal tissue response using new techniques to quantify these tissue responses. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Feed-forward control of gear mesh vibration using piezoelectric actuators
NASA Technical Reports Server (NTRS)
Montague, Gerald T.; Kascak, Albert F.; Palazzolo, Alan; Manchala, Daniel; Thomas, Erwin
1994-01-01
This paper presents a novel means for suppressing gear mesh-related vibrations. The key components in this approach are piezoelectric actuators and a high-frequency, analog feed-forward controller. Test results are presented and show up to a 70-percent reduction in gear mesh acceleration and vibration control up to 4500 Hz. The principle of the approach is explained by an analysis of a harmonically excited, general linear vibratory system.
Zhao, Fangkun; Shi, Bei; Liu, Ruixin; Zhou, Wenkai; Shi, Dong; Zhang, Jinsong
2018-04-03
The distribution pattern and knowledge structure of choroidal neovascularization (CNV) was surveyed based on literatures in PubMed. Published scientific papers about CNV were retrieved from Jan 1st, 2012 to May 31st, 2017. Extracted MeSH terms were analyzed quantitatively by using Bibliographic Item Co-Occurrence Matrix Builder (BICOMB) and high-frequency MeSH terms were identified. Hierarchical cluster analysis was conducted by SPSS 19.0 according to the MeSH term-source article matrix. High-frequency MeSH terms co-occurrence matrix was constructed to support strategic diagram and social network analysis (SNA). According to the searching strategy, all together 2366 papers were included, and the number of annual papers changed slightly from Jan 1st, 2012 to May 31st, 2017. Among all the extracted MeSH terms, 44 high-frequency MeSH terms were identified and hotspots were clustered into 6 categories. In the strategic diagram, clinical drug therapy, pathology and diagnosis related researches of CNV were well developed. In contrast, the metabolism, etiology, complications, prevention and control of CNV in animal models, and genetics related researches of CNV were relatively immature, which offers potential research space for future study. As for the SNA result, the position status of each component was described by the centrality values. The studies on CNV are relatively divergent and the 6 research categories concluded from this study could reflect the publication trends on CNV to some extent. By providing a quantitative bibliometric research across a 5-year span, it could help to depict an overall command of the latest topics and provide some hints for researchers when launching new projects.
Wang, Y T; Meheš, M M; Naseem, H-R; Ibrahim, M; Butt, M A; Ahmed, N; Wahab Bin Adam, M A; Issah, A-W; Mohammed, I; Goldstein, S D; Cartwright, K; Abdullah, F
2014-08-01
Inguinal hernia repair is the most common general surgery operation performed globally. However, the adoption of tension-free hernia repair with mesh has been limited in low-income settings, largely due to a lack of technical training and resources. The present study evaluates the impact of a 2-day training course instructing use of polypropylene mesh for inguinal hernia repair on the practice patterns of sub-Saharan African physicians. A surgical training course on tension-free mesh repair of hernias was provided to 16 physicians working in rural Ghanaian and Liberian hospitals. Three physicians were requested to prospectively record all their inguinal hernia surgeries, performed with or without mesh, during the 14-month period following the training. Demographic variables, diagnoses, and complications were collected by an independent data collector for mesh and non-mesh procedures. Surgery with mesh increased significantly following intervention, from near negligible levels prior to the training to 8.1 % of all inguinal hernia repairs afterwards. Mesh repair accounted for 90.8 % of recurrent hernia repairs and 2.9 % of primary hernia repairs after training. Overall complication rates between mesh and non-mesh procedures were not significantly different (p = 0.20). Three physicians who participated in an intensive education course were routinely using mesh for inguinal hernia repair 14 months after the training. This represents a significant change in practice pattern. Complication rates between patients who underwent inguinal hernia repairs with and without mesh were comparable. The present study provides evidence that short-term surgical training initiatives can have a substantial impact on local healthcare practice in resource-limited settings.
Emerging medical informatics research trends detection based on MeSH terms.
Lyu, Peng-Hui; Yao, Qiang; Mao, Jin; Zhang, Shi-Jing
2015-01-01
The aim of this study is to analyze the research trends of medical informatics over the last 12 years. A new method based on MeSH terms was proposed to identify emerging topics and trends of medical informatics research. Informetric methods and visualization technologies were applied to investigate research trends of medical informatics. The metric of perspective factor (PF) embedding MeSH terms was appropriately employed to assess the perspective quality for journals. The emerging MeSH terms have changed dramatically over the last 12 years, identifying two stages of medical informatics: the "medical imaging stage" and the "medical informatics stage". The focus of medical informatics has shifted from acquisition and storage of healthcare data by integrating computational, informational, cognitive and organizational sciences to semantic analysis for problem solving and clinical decision-making. About 30 core journals were determined by Bradford's Law in the last 3 years in this area. These journals, with high PF values, have relative high perspective quality and lead the trend of medical informatics.
Chang, Xing; Zhou, Xin; Luo, Linzhi; Yang, Chengjia; Pan, Hui; Zhang, Shuyang
2017-09-12
This study aimed to identify hotspots in research on clinical competence measurements from 2012 to 2016. The authors retrieved literature published between 2012 and 2016 from PubMed using selected medical subject headings (MeSH) terms. They used BibExcel software to generate high-frequency MeSH terms and identified hotspots by co-word analysis and cluster analysis. The authors searched 588 related articles and identified 31 high-frequency MeSH terms. In addition, they obtained 6 groups of high-frequency MeSH terms that reflected the domain hotspots. This study identified 6 hotspots of domain research, including studies on influencing factors and perception evaluation, improving and developing measurement tools, feedback measurement, measurement approaches based on computer simulation, the measurement of specific students in different learning phases, and the measurement of students' communication ability. All of these research topics could provide useful information for educators and researchers to continually conduct in-depth studies.
The contribution of morphological knowledge to French MeSH mapping for information retrieval.
Zweigenbaum, P.; Darmoni, S. J.; Grabar, N.
2001-01-01
MeSH-indexed Internet health directories must provide a mapping from natural language queries to MeSH terms so that both health professionals and the general public can query their contents. We describe here the design of lexical knowledge bases for mapping French expressions to MeSH terms, and the initial evaluation of their contribution to Doc'CISMeF, the search tool of a MeSH-indexed directory of French-language medical Internet resources. The observed trend is in favor of the use of morphological knowledge as a moderate (approximately 5%) but effective factor for improving query to term mapping capabilities. PMID:11825295
Cooper, Gregory F.; Miller, Randolph A.
1998-01-01
Abstract Objective: A primary goal of the University of Pittsburgh's 1990-94 UMLS-sponsored effort was to develop and evaluate PostDoc (a lexical indexing system) and Pindex (a statistical indexing system) comparatively, and then in combination as a hybrid system. Each system takes as input a portion of the free text from a narrative part of a patient's electronic medical record and returns a list of suggested MeSH terms to use in formulating a Medline search that includes concepts in the text. This paper describes the systems and reports an evaluation. The intent is for this evaluation to serve as a step toward the eventual realization of systems that assist healthcare personnel in using the electronic medical record to construct patient-specific searches of Medline. Design: The authors tested the performances of PostDoc, Pindex, and a hybrid system, using text taken from randomly selected clinical records, which were stratified to include six radiology reports, six pathology reports, and six discharge summaries. They identified concepts in the clinical records that might conceivably be used in performing a patient-specific Medline search. Each system was given the free text of each record as an input. The extent to which a system-derived list of MeSH terms captured the relevant concepts in these documents was determined based on blinded assessments by the authors. Results: PostDoc output a mean of approximately 19 MeSH terms per report, which included about 40% of the relevant report concepts. Pindex output a mean of approximately 57 terms per report and captured about 45% of the relevant report concepts. A hybrid system captured approximately 66% of the relevant concepts and output about 71 terms per report. Conclusion: The outputs of PostDoc and Pindex are complementary in capturing MeSH terms from clinical free text. The results suggest possible approaches to reduce the number of terms output while maintaining the percentage of terms captured, including the use of UMLS semantic types to constrain the output list to contain only clinically relevant MeSH terms. PMID:9452986
Computational Systems for Multidisciplinary Applications
NASA Technical Reports Server (NTRS)
Soni, Bharat; Haupt, Tomasz; Koomullil, Roy; Luke, Edward; Thompson, David
2002-01-01
In this paper, we briefly describe our efforts to develop complex simulation systems. We focus first on four key infrastructure items: enterprise computational services, simulation synthesis, geometry modeling and mesh generation, and a fluid flow solver for arbitrary meshes. We conclude by presenting three diverse applications developed using these technologies.
Long-term anisotropic mechanical response of surgical meshes used to repair abdominal wall defects.
Hernández-Gascón, B; Peña, E; Pascual, G; Rodríguez, M; Bellón, J M; Calvo, B
2012-01-01
Routine hernia repair surgery involves the implant of synthetic mesh. However, this type of procedure may give rise to pain and bowel incarceration and strangulation, causing considerable patient disability. The purpose of this study was to compare the long-term behaviour of three commercial meshes used to repair the partially herniated abdomen in New Zealand White rabbits: the heavyweight (HW) mesh, Surgipro(®) and lightweight (LW) mesh, Optilene(®), both made of polypropylene (PP), and a mediumweight (MW) mesh, Infinit(®), made of polytetrafluoroethylene (PTFE). The implanted meshes were mechanical and histological assessed at 14, 90 and 180 days post-implant. This behaviour was compared to the anisotropic mechanical behaviour of the unrepaired abdominal wall in control non-operated rabbits. Both uniaxial mechanical tests conducted in craneo-caudal and perpendicular directions and histological findings revealed substantial collagen growth over the repaired hernial defects causing stiffness in the repair zone, and thus a change in the original properties of the meshes. The mechanical behaviour of the healthy tissue in the craneo-caudal direction was not reproduced by any of the implanted meshes after 14 days or 90 days of implant, whereas in the perpendicular direction, SUR and OPT achieved similar behaviour. From a mechanical standpoint, the anisotropic PP-lightweight meshes may be considered a good choice in the long run, which correlates with the structure of the regenerated tissue. Copyright © 2011 Elsevier Ltd. All rights reserved.
Tainaka, Hitoshi; Takahashi, Hikari; Umezawa, Masakazu; Tanaka, Hiromitsu; Nishimune, Yoshitake; Oshio, Shigeru; Takeda, Ken
2012-01-01
Bisphenol A (BPA) is known to be an endocrine disruptor that affects the development of reproductive system. The aim of the present study was to investigate a group of testicular genes dysregulated by prenatal exposure to BPA. Pregnant ICR mice were treated with BPA by subcutaneous administration on days 7 and 14 of pregnancy. Tissue and blood samples were collected from 6-week-old male offspring. Testes were subjected to gene expression analysis using a testis-specific microarray (Testis2), consisting of 2,482 mouse cDNA clones annotated with Medical Subject Headings (MeSH) terms indicative of testicular components and functions. To interpret the microarray data, we used the MeSH terms significantly associated with the altered genes. As a result, MeSH terms related to androgens and Sertoli cells were extracted in BPA-treated groups. Among the genes related to Sertoli cells, downregulation of Msi1h, Ncoa1, Nid1, Hspb2, and Gata6 were detected in the testis of mice treated with BPA (twice administered 50 mg/kg). The MeSH terms associated with this group of genes may provide useful means to interpret the testicular toxicity of BPA. This article concludes that prenatal BPA exposure downregulates expression of genes associated with Sertoli cell function and affects the reproductive function of male offspring. Additionally, a method using MeSH to extract a group of genes was useful for predicting the testicular and reproductive toxicity of prenatal BPA exposure.
Köckerling, F; Alam, N N; Antoniou, S A; Daniels, I R; Famiglietti, F; Fortelny, R H; Heiss, M M; Kallinowski, F; Kyle-Leinhase, I; Mayer, F; Miserez, M; Montgomery, A; Morales-Conde, S; Muysoms, F; Narang, S K; Petter-Puchner, A; Reinpold, W; Scheuerlein, H; Smietanski, M; Stechemesser, B; Strey, C; Woeste, G; Smart, N J
2018-04-01
Although many surgeons have adopted the use of biologic and biosynthetic meshes in complex abdominal wall hernia repair, others have questioned the use of these products. Criticism is addressed in several review articles on the poor standard of studies reporting on the use of biologic meshes for different abdominal wall repairs. The aim of this consensus review is to conduct an evidence-based analysis of the efficacy of biologic and biosynthetic meshes in predefined clinical situations. A European working group, "BioMesh Study Group", composed of invited surgeons with a special interest in surgical meshes, formulated key questions, and forwarded them for processing in subgroups. In January 2016, a workshop was held in Berlin where the findings were presented, discussed, and voted on for consensus. Findings were set out in writing by the subgroups followed by consensus being reached. For the review, 114 studies and background analyses were used. The cumulative data regarding biologic mesh under contaminated conditions do not support the claim that it is better than synthetic mesh. Biologic mesh use should be avoided when bridging is needed. In inguinal hernia repair biologic and biosynthetic meshes do not have a clear advantage over the synthetic meshes. For prevention of incisional or parastomal hernias, there is no evidence to support the use of biologic/biosynthetic meshes. In complex abdominal wall hernia repairs (incarcerated hernia, parastomal hernia, infected mesh, open abdomen, enterocutaneous fistula, and component separation technique), biologic and biosynthetic meshes do not provide a superior alternative to synthetic meshes. The routine use of biologic and biosynthetic meshes cannot be recommended.
Lukban, James C.; Beyer, Roger D.; Moore, Robert D.
2012-01-01
Introduction and Hypothesis. We sought to determine the mesh extrusion (vaginal exposure) rates and subject outcomes following IntePro (Type I polypropylene) mesh “kit” repairs for vaginal prolapse. Methods. Data were pooled from two prospective multicenter studies evaluating the safety and efficacy of the Perigee and Apogee (American Medical Systems, Minnetonka, Minn, USA) to treat anterior and posterior/apical prolapses, respectively. Extrusions involving the anterior compartment (AC) or posterior compartment/apex (PC/A) were recorded. Results. Two hundred sixty women underwent mesh placement, with a total of 368 mesh units inserted (173 in the AC and 195 in the PC/A). Extrusions were noted in 13 (7.5%) of AC implants and 27 (13.8%) of PC/A implants through 12 months. No difference was seen between those with and without extrusion in regard to anatomic cure, postoperative painor quality of life at 1 year. Conclusions. Extrusion had no apparent effect on short-term outcomes. Given the unknown long-term sequellae of vaginal mesh exposure, a thorough assessment of risks and benefits of transvaginal mesh placement should be considered at the time of preoperative planning. PMID:22190952
Reconfigurable lattice mesh designs for programmable photonic processors.
Pérez, Daniel; Gasulla, Ivana; Capmany, José; Soref, Richard A
2016-05-30
We propose and analyse two novel mesh design geometries for the implementation of tunable optical cores in programmable photonic processors. These geometries are the hexagonal and the triangular lattice. They are compared here to a previously proposed square mesh topology in terms of a series of figures of merit that account for metrics that are relevant to on-chip integration of the mesh. We find that that the hexagonal mesh is the most suitable option of the three considered for the implementation of the reconfigurable optical core in the programmable processor.
Key concepts in consumer and community engagement: a scoping meta-review.
Sarrami-Foroushani, Pooria; Travaglia, Joanne; Debono, Deborah; Braithwaite, Jeffrey
2014-06-13
Although consumer and community engagement (CCE) in health care is receiving increasing attention, research and practice in this area are hampered by the variability of concepts and terminology commonly employed. This scoping meta-review aims to identify key CCE concepts and examine terminology used to describe them. In a scoping meta-review, an extensive list of 47 phrases and 11 Medical Subject Headings (MeSH) was used to undertake a comprehensive and systematic search in PubMed Central, Embase, EBM reviews, CINAHL, APAPsycNET, and Scopus. 59 systematic reviews met the selection criteria and were included in the final analysis. The analysis identified nine different concepts related to CCE: shared decision making, self-management, CCE in health care systems, community-based health promotion, providing access to health care, rehabilitation, participation in research, collaboration in research design and conduct, and peer support. The identified concepts differ from each other in many aspects including the aim of the activity, the role of consumers and the type of professionals' involvement. Each concept was described by a range of terms, with some terms shared by different concepts. In addition, two overlapping concepts of patient-centeredness and patient empowerment were recognised. This study describes CCE-related key concepts and provides new insight into their relationship with different CCE-related terms. Identification of key CCE-related concepts and terms will be useful to focus future studies and initiatives and enhance production of CCE-related evidence.
Key concepts in consumer and community engagement: a scoping meta-review
2014-01-01
Background Although consumer and community engagement (CCE) in health care is receiving increasing attention, research and practice in this area are hampered by the variability of concepts and terminology commonly employed. This scoping meta-review aims to identify key CCE concepts and examine terminology used to describe them. Methods In a scoping meta-review, an extensive list of 47 phrases and 11 Medical Subject Headings (MeSH) was used to undertake a comprehensive and systematic search in PubMed Central, Embase, EBM reviews, CINAHL, APAPsycNET, and Scopus. Results 59 systematic reviews met the selection criteria and were included in the final analysis. The analysis identified nine different concepts related to CCE: shared decision making, self-management, CCE in health care systems, community-based health promotion, providing access to health care, rehabilitation, participation in research, collaboration in research design and conduct, and peer support. The identified concepts differ from each other in many aspects including the aim of the activity, the role of consumers and the type of professionals’ involvement. Each concept was described by a range of terms, with some terms shared by different concepts. In addition, two overlapping concepts of patient-centeredness and patient empowerment were recognised. Conclusions This study describes CCE-related key concepts and provides new insight into their relationship with different CCE-related terms. Identification of key CCE-related concepts and terms will be useful to focus future studies and initiatives and enhance production of CCE-related evidence. PMID:24923771
2013-01-01
Background PubMed translations of OvidSP Medline search filters offer searchers improved ease of access. They may also facilitate access to PubMed’s unique content, including citations for the most recently published biomedical evidence. Retrieving this content requires a search strategy comprising natural language terms (‘textwords’), rather than Medical Subject Headings (MeSH). We describe a reproducible methodology that uses a validated PubMed search filter translation to create a textword-only strategy to extend retrieval to PubMed’s unique heart failure literature. Methods We translated an OvidSP Medline heart failure search filter for PubMed and established version equivalence in terms of indexed literature retrieval. The PubMed version was then run within PubMed to identify citations retrieved by the filter’s MeSH terms (Heart failure, Left ventricular dysfunction, and Cardiomyopathy). It was then rerun with the same MeSH terms restricted to searching on title and abstract fields (i.e. as ‘textwords’). Citations retrieved by the MeSH search but not the textword search were isolated. Frequency analysis of their titles/abstracts identified natural language alternatives for those MeSH terms that performed less effectively as textwords. These terms were tested in combination to determine the best performing search string for reclaiming this ‘lost set’. This string, restricted to searching on PubMed’s unique content, was then combined with the validated PubMed translation to extend the filter’s performance in this database. Results The PubMed heart failure filter retrieved 6829 citations. Of these, 834 (12%) failed to be retrieved when MeSH terms were converted to textwords. Frequency analysis of the 834 citations identified five high frequency natural language alternatives that could improve retrieval of this set (cardiac failure, cardiac resynchronization, left ventricular systolic dysfunction, left ventricular diastolic dysfunction, and LV dysfunction). Together these terms reclaimed 157/834 (18.8%) of lost citations. Conclusions MeSH terms facilitate precise searching in PubMed’s indexed subset. They may, however, work less effectively as search terms prior to subject indexing. A validated PubMed search filter can be used to develop a supplementary textword-only search strategy to extend retrieval to PubMed’s unique content. A PubMed heart failure search filter is available on the CareSearch website (http://www.caresearch.com.au) providing access to both indexed and non-indexed heart failure evidence. PMID:23819658
NASA Astrophysics Data System (ADS)
Garcia-Fresnillo, L.; Shemet, V.; Chyrkin, A.; de Haart, L. G. J.; Quadakkers, W. J.
2014-12-01
In the present study the long-term behaviour of two ferritic steels, Crofer 22 APU and Crofer 22H, in contact with a Ni-mesh during exposure in simulated anode gas, Ar-4%H2-2%H2O, at 700 and 800 °C for exposure times up to 3000 h was investigated. Ni diffusion from the Ni-mesh into the steel resulted in the formation of an austenitic zone whereas diffusion of iron and chromium from the steel into the Ni-mesh resulted in the formation of chromia base oxides in the Ni-mesh. Depending on the chemical composition of the steel, the temperature and the exposure time, interdiffusion processes between ferritic steel and Ni-mesh also resulted in σ-phase formation at the austenite-ferrite interface and in Laves-phase dissolution in the austenitic zone. The extent and morphology of the σ-phase formation are discussed on the basis of thermodynamic considerations, including reaction paths in the ternary alloy system Fe-Ni-Cr.
Long-term follow-up results of umbilical hernia repair.
Venclauskas, Linas; Jokubauskas, Mantas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas
2017-12-01
Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias (< 2 cm) had a recurrence in the suture repair group. Logistic regression analysis showed that body mass index (BMI) > 30 kg/m 2 , diabetes and wound infection were independent risk factors for umbilical hernia recurrence. The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m 2 , diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence.
[Deep infiltrating endometriosis surgical management and pelvic nerves injury].
Fermaut, M; Nyangoh Timoh, K; Lebacle, C; Moszkowicz, D; Benoit, G; Bessede, T
2016-05-01
Deep pelvic endometriosis surgery may need substantial excisions, which in turn expose to risks of injury to the pelvic nerves. To limit functional complications, nerve-sparing surgical techniques have been developed but should be adapted to the specific multifocal character of endometriotic lesions. The objective was to identify the anatomical areas where the pelvic nerves are most at risk of injury during endometriotic excisions. The Medline and Embase databases have been searched for available literature using the keywords "hypogastric nerve or hypogastric plexus [Mesh] or autonomic pathway [Mesh], anatomy, endometriosis, surgery [Mesh]". All relevant French and English publications, selected based on their available abstracts, have been reviewed. Five female adult fresh cadavers have been dissected to localize the key anatomical areas where the pelvic nerves are most at risk of injury. Six anatomical areas of high risk for pelvic nerves have been identified, analysed and described. Pelvic nerves can be damaged during the dissection of retrorectal space and the anterolateral rectal excision. Furthermore, before an uterosacral ligament excision, a parametrial excision, a colpectomy or a dissection of the vesico-uterine ligament, the hypogastric nerves, splanchnic nerves, inferior hypogastric plexus and its efferent pathways must be mapped out to avoid injury. The distance between the deep uterin vein and the pelvic splanchnic nerves were measured on four cadavers and varied from 2.5cm to 4cm. Six key anatomical pitfalls must be known in order to limit the functional complications of the endometriotic surgical excision. Applying nerve-sparing surgical techniques for endometriosis would lead to less urinary functional complications and a better short-term postoperative satisfaction. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
2018-02-15
conservation equations. The closure problem hinges on the evaluation of the filtered chemical production rates. In MRA/MSR, simultaneous large-eddy...simulations of a reactive flow are performed at different mesh resolution levels. The solutions at each coarser mesh level are constrained by the filtered ...include the replacement of chemical production rates with those filtered from the underlying fine mesh and the construction of ‘exact’ forms for
An Angular Method with Position Control for Block Mesh Squareness Improvement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, J.; Stillman, D.
We optimize a target function de ned by angular properties with a position control term for a basic stencil with a block-structured mesh, to improve element squareness in 2D and 3D. Comparison with the condition number method shows that besides a similar mesh quality regarding orthogonality can be achieved as the former does, the new method converges faster and provides a more uniform global mesh spacing in our numerical tests.
Solution adaptive grids applied to low Reynolds number flow
NASA Astrophysics Data System (ADS)
de With, G.; Holdø, A. E.; Huld, T. A.
2003-08-01
A numerical study has been undertaken to investigate the use of a solution adaptive grid for flow around a cylinder in the laminar flow regime. The main purpose of this work is twofold. The first aim is to investigate the suitability of a grid adaptation algorithm and the reduction in mesh size that can be obtained. Secondly, the uniform asymmetric flow structures are ideal to validate the mesh structures due to mesh refinement and consequently the selected refinement criteria. The refinement variable used in this work is a product of the rate of strain and the mesh cell size, and contains two variables Cm and Cstr which determine the order of each term. By altering the order of either one of these terms the refinement behaviour can be modified.
Reliability optimization design of the gear modification coefficient based on the meshing stiffness
NASA Astrophysics Data System (ADS)
Wang, Qianqian; Wang, Hui
2018-04-01
Since the time varying meshing stiffness of gear system is the key factor affecting gear vibration, it is important to design the meshing stiffness to reduce vibration. Based on the effect of gear modification coefficient on the meshing stiffness, considering the random parameters, reliability optimization design of the gear modification is researched. The dimension reduction and point estimation method is used to estimate the moment of the limit state function, and the reliability is obtained by the forth moment method. The cooperation of the dynamic amplitude results before and after optimization indicates that the research is useful for the reduction of vibration and noise and the improvement of the reliability.
Biomechanical properties of synthetic surgical meshes for pelvic prolapse repair.
Todros, S; Pavan, P G; Natali, A N
2015-03-01
Synthetic meshes are widely used for surgical repair of different kind of prolapses. In the light of the experience of abdominal wall repair, similar prostheses are currently used in the pelvic region, to restore physiological anatomy after organ prolapse into the vaginal wall, that represent a recurrent dysfunction. For this purpose, synthetic meshes are surgically positioned in contact with the anterior and/or posterior vaginal wall, to inferiorly support prolapsed organs. Nonetheless, while mesh implantation restores physiological anatomy, it is often associated with different complications in the vaginal region. These potentially dangerous effects induce the surgical community to reconsider the safety and efficacy of mesh transvaginal placement. For this purpose, the evaluation of state-of-the-art research may provide the basis for a comprehensive analysis of mesh compatibility and functionality. The aim of this work is to review synthetic surgical meshes for pelvic organs prolapse repair, taking into account the mechanics of mesh material and structure, and to relate them with pelvic and vaginal tissue biomechanics. Synthetic meshes are currently available in different chemical composition, fiber and textile conformations. Material and structural properties are key factors in determining mesh biochemical and mechanical compatibility in vivo. The most significant results on vaginal tissue and surgical meshes mechanical characterization are here reported and discussed. Moreover, computational models of the pelvic region, which could support the surgeon in the evaluation of mesh performances in physiological conditions, are recalled. Copyright © 2015 Elsevier Ltd. All rights reserved.
Modelling atmospheric flows with adaptive moving meshes
NASA Astrophysics Data System (ADS)
Kühnlein, Christian; Smolarkiewicz, Piotr K.; Dörnbrack, Andreas
2012-04-01
An anelastic atmospheric flow solver has been developed that combines semi-implicit non-oscillatory forward-in-time numerics with a solution-adaptive mesh capability. A key feature of the solver is the unification of a mesh adaptation apparatus, based on moving mesh partial differential equations (PDEs), with the rigorous formulation of the governing anelastic PDEs in generalised time-dependent curvilinear coordinates. The solver development includes an enhancement of the flux-form multidimensional positive definite advection transport algorithm (MPDATA) - employed in the integration of the underlying anelastic PDEs - that ensures full compatibility with mass continuity under moving meshes. In addition, to satisfy the geometric conservation law (GCL) tensor identity under general moving meshes, a diagnostic approach is proposed based on the treatment of the GCL as an elliptic problem. The benefits of the solution-adaptive moving mesh technique for the simulation of multiscale atmospheric flows are demonstrated. The developed solver is verified for two idealised flow problems with distinct levels of complexity: passive scalar advection in a prescribed deformational flow, and the life cycle of a large-scale atmospheric baroclinic wave instability showing fine-scale phenomena of fronts and internal gravity waves.
Exploiting MeSH indexing in MEDLINE to generate a data set for word sense disambiguation.
Jimeno-Yepes, Antonio J; McInnes, Bridget T; Aronson, Alan R
2011-06-02
Evaluation of Word Sense Disambiguation (WSD) methods in the biomedical domain is difficult because the available resources are either too small or too focused on specific types of entities (e.g. diseases or genes). We present a method that can be used to automatically develop a WSD test collection using the Unified Medical Language System (UMLS) Metathesaurus and the manual MeSH indexing of MEDLINE. We demonstrate the use of this method by developing such a data set, called MSH WSD. In our method, the Metathesaurus is first screened to identify ambiguous terms whose possible senses consist of two or more MeSH headings. We then use each ambiguous term and its corresponding MeSH heading to extract MEDLINE citations where the term and only one of the MeSH headings co-occur. The term found in the MEDLINE citation is automatically assigned the UMLS CUI linked to the MeSH heading. Each instance has been assigned a UMLS Concept Unique Identifier (CUI). We compare the characteristics of the MSH WSD data set to the previously existing NLM WSD data set. The resulting MSH WSD data set consists of 106 ambiguous abbreviations, 88 ambiguous terms and 9 which are a combination of both, for a total of 203 ambiguous entities. For each ambiguous term/abbreviation, the data set contains a maximum of 100 instances per sense obtained from MEDLINE.We evaluated the reliability of the MSH WSD data set using existing knowledge-based methods and compared their performance to that of the results previously obtained by these algorithms on the pre-existing data set, NLM WSD. We show that the knowledge-based methods achieve different results but keep their relative performance except for the Journal Descriptor Indexing (JDI) method, whose performance is below the other methods. The MSH WSD data set allows the evaluation of WSD algorithms in the biomedical domain. Compared to previously existing data sets, MSH WSD contains a larger number of biomedical terms/abbreviations and covers the largest set of UMLS Semantic Types. Furthermore, the MSH WSD data set has been generated automatically reusing already existing annotations and, therefore, can be regenerated from subsequent UMLS versions.
Long-term follow-up results of umbilical hernia repair
Venclauskas, Linas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas
2017-01-01
Introduction Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. Aim To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. Material and methods A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. Results One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias (< 2 cm) had a recurrence in the suture repair group. Logistic regression analysis showed that body mass index (BMI) > 30 kg/m2, diabetes and wound infection were independent risk factors for umbilical hernia recurrence. Conclusions The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m2, diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence. PMID:29362649
Summary on several key techniques in 3D geological modeling.
Mei, Gang
2014-01-01
Several key techniques in 3D geological modeling including planar mesh generation, spatial interpolation, and surface intersection are summarized in this paper. Note that these techniques are generic and widely used in various applications but play a key role in 3D geological modeling. There are two essential procedures in 3D geological modeling: the first is the simulation of geological interfaces using geometric surfaces and the second is the building of geological objects by means of various geometric computations such as the intersection of surfaces. Discrete geometric surfaces that represent geological interfaces can be generated by creating planar meshes first and then spatially interpolating; those surfaces intersect and then form volumes that represent three-dimensional geological objects such as rock bodies. In this paper, the most commonly used algorithms of the key techniques in 3D geological modeling are summarized.
Glazener, Cathryn; Breeman, Suzanne; Elders, Andrew; Hemming, Christine; Cooper, Kevin; Freeman, Robert; Smith, Anthony; Hagen, Suzanne; Montgomery, Isobel; Kilonzo, Mary; Boyers, Dwayne; McDonald, Alison; McPherson, Gladys; MacLennan, Graeme; Norrie, John
2016-12-01
The use of mesh in prolapse surgery is controversial, leading to a number of enquiries into its safety and efficacy. To compare synthetic non-absorbable mesh inlay, biological graft and mesh kit with a standard repair in terms of clinical effectiveness, adverse effects, quality of life (QoL), costs and cost-effectiveness. Two randomised controlled trials within a comprehensive cohort (CC) study. Allocation was by a remote web-based randomisation system in a 1 :1 : 1 ratio (Primary trial) or 1 : 1 : 2 ratio (Secondary trial), and was minimised on age, type of prolapse repair planned, need for a concomitant continence procedure, need for a concomitant upper vaginal prolapse procedure and surgeon. Participants and outcome assessors were blinded to randomisation; participants were unblinded if they requested the information. Surgeons were not blinded to allocated procedure. Thirty-five UK hospitals. Primary study : 2474 women in the analysis (including 1348 randomised) having primary anterior or posterior prolapse surgery. Secondary study : 398 in the analysis (including 154 randomised) having repeat anterior or posterior prolapse surgery. CC3 : 215 women having either uterine or vault prolapse repair. Anterior or posterior repair alone, or with mesh inlay, biological graft or mesh kit. Prolapse symptoms [Pelvic Organ Prolapse Symptom Score (POP-SS)]; prolapse-specific QoL; cost-effectiveness [incremental cost per quality-adjusted life-year (QALY)]. Primary trials : adjusting for baseline and minimisation covariates, mean POP-SS was similar for each comparison {standard 5.4 [standard deviation (SD) 5.5] vs. mesh 5.5 (SD 5.1), mean difference (MD) 0.00, 95% confidence interval (CI) -0.70 to 0.71; standard 5.5 (SD 5.6) vs. graft 5.6 (SD 5.6), MD -0.15, 95% CI -0.93 to 0.63}. Serious non-mesh adverse effects rates were similar between the groups in year 1 [standard 7.2% vs. mesh 7.8%, risk ratio (RR) 1.08, 95% CI 0.68 to 1.72; standard 6.3% vs. graft 9.8%, RR 1.57, 95% CI 0.95 to 2.59]. There were no statistically significant differences between groups in any other outcome measure. The cumulative mesh complication rates over 2 years were 2 of 430 (0.5%) for standard repair (trial 1), 46 of 435 (10.6%) for mesh inlay and 2 of 368 (0.5%) for biological graft. The CC findings were comparable. Incremental costs were £363 (95% CI -£32 to £758) and £565 (95% CI £180 to £950) for mesh and graft vs. standard, respectively. Incremental QALYs were 0.071 (95% CI -0.004 to 0.145) and 0.039 (95% CI -0.041 to 0.120) for mesh and graft vs. standard, respectively. A Markov decision model extrapolating trial results over 5 years showed standard repair had the highest probability of cost-effectiveness, but results were surrounded by considerable uncertainty. Secondary trials : there were no statistically significant differences between the randomised groups in any outcome measure, but the sample size was too small to be conclusive. The cumulative mesh complication rates over 2 years were 7 of 52 (13.5%) for mesh inlay and 4 of 46 (8.7%) for mesh kit, with no mesh exposures for standard repair. In women who were having primary repairs, there was evidence of no benefit from the use of mesh inlay or biological graft compared with standard repair in terms of efficacy, QoL or adverse effects (other than mesh complications) in the short term. The Secondary trials were too small to provide conclusive results. Women in the Primary trials included some with a previous repair in another compartment. Follow-up is vital to identify any long-term potential benefits and serious adverse effects. Long-term follow-up to at least 6 years after surgery is ongoing to identify recurrence rates, need for further prolapse surgery, adverse effects and cost-effectiveness. Current Controlled Trials ISRCTN60695184. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 20, No. 95. See the NIHR Journals Library website for further project information.
Design and simulation of origami structures with smooth folds
Peraza Hernandez, E. A.; Lagoudas, D. C.
2017-01-01
Origami has enabled new approaches to the fabrication and functionality of multiple structures. Current methods for origami design are restricted to the idealization of folds as creases of zeroth-order geometric continuity. Such an idealization is not proper for origami structures of non-negligible fold thickness or maximum curvature at the folds restricted by material limitations. For such structures, folds are not properly represented as creases but rather as bent regions of higher-order geometric continuity. Such fold regions of arbitrary order of continuity are termed as smooth folds. This paper presents a method for solving the following origami design problem: given a goal shape represented as a polygonal mesh (termed as the goal mesh), find the geometry of a single planar sheet, its pattern of smooth folds, and the history of folding motion allowing the sheet to approximate the goal mesh. The parametrization of the planar sheet and the constraints that allow for a valid pattern of smooth folds are presented. The method is tested against various goal meshes having diverse geometries. The results show that every determined sheet approximates its corresponding goal mesh in a known folded configuration having fold angles obtained from the geometry of the goal mesh. PMID:28484322
Design and simulation of origami structures with smooth folds.
Peraza Hernandez, E A; Hartl, D J; Lagoudas, D C
2017-04-01
Origami has enabled new approaches to the fabrication and functionality of multiple structures. Current methods for origami design are restricted to the idealization of folds as creases of zeroth-order geometric continuity. Such an idealization is not proper for origami structures of non-negligible fold thickness or maximum curvature at the folds restricted by material limitations. For such structures, folds are not properly represented as creases but rather as bent regions of higher-order geometric continuity. Such fold regions of arbitrary order of continuity are termed as smooth folds . This paper presents a method for solving the following origami design problem: given a goal shape represented as a polygonal mesh (termed as the goal mesh ), find the geometry of a single planar sheet, its pattern of smooth folds, and the history of folding motion allowing the sheet to approximate the goal mesh. The parametrization of the planar sheet and the constraints that allow for a valid pattern of smooth folds are presented. The method is tested against various goal meshes having diverse geometries. The results show that every determined sheet approximates its corresponding goal mesh in a known folded configuration having fold angles obtained from the geometry of the goal mesh.
Mesh electronics: a new paradigm for tissue-like brain probes.
Hong, Guosong; Yang, Xiao; Zhou, Tao; Lieber, Charles M
2018-06-01
Existing implantable neurotechnologies for understanding the brain and treating neurological diseases have intrinsic properties that have limited their capability to achieve chronically-stable brain interfaces with single-neuron spatiotemporal resolution. These limitations reflect what has been dichotomy between the structure and mechanical properties of living brain tissue and non-living neural probes. To bridge the gap between neural and electronic networks, we have introduced the new concept of mesh electronics probes designed with structural and mechanical properties such that the implant begins to 'look and behave' like neural tissue. Syringe-implanted mesh electronics have led to the realization of probes that are neuro-attractive and free of the chronic immune response, as well as capable of stable long-term mapping and modulation of brain activity at the single-neuron level. This review provides a historical overview of a 10-year development of mesh electronics by highlighting the tissue-like design, syringe-assisted delivery, seamless neural tissue integration, and single-neuron level chronic recording stability of mesh electronics. We also offer insights on unique near-term opportunities and future directions for neuroscience and neurology that now are available or expected for mesh electronics neurotechnologies. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
2013-01-01
Background Multicellular organisms consist of cells of many different types that are established during development. Each type of cell is characterized by the unique combination of expressed gene products as a result of spatiotemporal gene regulation. Currently, a fundamental challenge in regulatory biology is to elucidate the gene expression controls that generate the complex body plans during development. Recent advances in high-throughput biotechnologies have generated spatiotemporal expression patterns for thousands of genes in the model organism fruit fly Drosophila melanogaster. Existing qualitative methods enhanced by a quantitative analysis based on computational tools we present in this paper would provide promising ways for addressing key scientific questions. Results We develop a set of computational methods and open source tools for identifying co-expressed embryonic domains and the associated genes simultaneously. To map the expression patterns of many genes into the same coordinate space and account for the embryonic shape variations, we develop a mesh generation method to deform a meshed generic ellipse to each individual embryo. We then develop a co-clustering formulation to cluster the genes and the mesh elements, thereby identifying co-expressed embryonic domains and the associated genes simultaneously. Experimental results indicate that the gene and mesh co-clusters can be correlated to key developmental events during the stages of embryogenesis we study. The open source software tool has been made available at http://compbio.cs.odu.edu/fly/. Conclusions Our mesh generation and machine learning methods and tools improve upon the flexibility, ease-of-use and accuracy of existing methods. PMID:24373308
Low Profile Mesh Plating for Patella Fractures: Video of a Novel Surgical Technique.
Verbeek, Diederik O; Hickerson, Lindsay E; Warner, Stephen J; Helfet, David L; Lorich, Dean G
2016-08-01
Patella fractures can be challenging to treat particularly in the presence of inferior pole comminution. In this video we present a novel surgical technique for the treatment of patella fractures using a small fragment low profile mesh plate. Key points are the surgical exposure with direct visualization of the articular reduction, the preparation of the mesh plate to accommodate patellar anatomy and the augmentation of the construct using Krackow sutures to address inferior pole comminution. Low profile mesh plating allows for multiplanar fixation of patella fractures while avoiding implant and fixation problems related to tension band fixation. Our early experience with this technique is encouraging and it appears that this technique is useful for the treatment of the majority of patella fractures.
Parallel performance optimizations on unstructured mesh-based simulations
Sarje, Abhinav; Song, Sukhyun; Jacobsen, Douglas; ...
2015-06-01
This paper addresses two key parallelization challenges the unstructured mesh-based ocean modeling code, MPAS-Ocean, which uses a mesh based on Voronoi tessellations: (1) load imbalance across processes, and (2) unstructured data access patterns, that inhibit intra- and inter-node performance. Our work analyzes the load imbalance due to naive partitioning of the mesh, and develops methods to generate mesh partitioning with better load balance and reduced communication. Furthermore, we present methods that minimize both inter- and intranode data movement and maximize data reuse. Our techniques include predictive ordering of data elements for higher cache efficiency, as well as communication reduction approaches.more » We present detailed performance data when running on thousands of cores using the Cray XC30 supercomputer and show that our optimization strategies can exceed the original performance by over 2×. Additionally, many of these solutions can be broadly applied to a wide variety of unstructured grid-based computations.« less
Gao, Yue; Krpata, David M; Criss, Cory N; Liu, Lijia; Posielski, Natasza; Rosen, Michael J; Novitsky, Yuri W
2014-08-01
The aim of this study was to reveal the effect of fibroblast or mesenchymal stem cell (MSC) coating on the mesh-induced production of IL-1β, IL-6, and VEGF by macrophages. Four commonly used surgical meshes were tested in this study, including Parietex, SoftMesh, TIGR, and Strattice. One-square-centimeter pieces of each mesh were placed on top of a monolayer of human fibroblasts or rat MSCs. The coating status was monitored with a light microscope. The human promonocytic cell line U937 was induced to differentiate into macrophages (MΦ). Three weeks later, meshes were transferred to new 24-well plates and cocultured with the MΦs for 72 h. Culture medium was collected and analyzed for IL-1β, IL-6, and VEGF production using standard ELISA essays. Parallel mesh samples were fixed with paraformaldehyde or glutaraldehyde for histology or transmission electronic microscopy (TEM) analyses, respectively. Uncoated meshes induced increased production of all three cytokines compared with macrophages cultured alone. HF coating further increased the production of both IL-6 and VEGF but reduced IL-1β production. Except for the SoftMesh group, MSC coating significantly blunted release of all cytokines to levels even lower than with MΦs cultured alone. MΦs tended to deteriorate in the presence of MSCs. Both histology and TEM revealed intimate interactions between cell-coated meshes and MΦs. Cytokine response to fibroblast coating varied, while MSC coating blunted the immunogenic effect of both synthetic and biologic meshes in vitro. Cell coating appears to affect mesh biocompatibility and may become a key process in mesh evolution.
Mirjavan, Mohammad; Asayesh, Azita; Asgharian Jeddi, Ali Asghar
2017-02-01
Surgical mesh is being used for healing hernia, pelvic organ prolapse, skull injuries and urinary incontinence. In this research the effect of fabric structure on the mechanical properties of warp knitted surgical meshes in comparison to abdominal fascia has been investigated. For this purpose, warp knitted surgical mesh with five different structures (Tricot, Pin-hole-net, quasi-Sandfly, Sandfly and quasi-Marquissite) were produced using polypropylene monofilament. Thereafter, their mechanical properties such as uniaxial tensile behavior in various directions (wale-wise (90°), course-wise (0°) and diagonal (45°)), bending resistance and crease recovery were analyzed. The meshes demonstrated different elastic modulus in various directions, which can be attributed to the pore shape (pore angle) and underlap angle in the structure of mesh. Except Pin-hole-net mesh, other produced meshes exhibited better level of orthotropy in comparison to abdominal fascia. The most flexible mesh in both wale-wise and course-wise directions was quasi-Sandfly and thereafter quasi-Marquissite. Tricot and Pin-hole-net manifested the highest crease recovery in wale-wise and coursewise directions respectively. The most desirable mesh in terms of porosity was quasi-Marquissite mesh. Overall, the quasi-Marquissite mesh was selected as the most suitable surgical mesh considering all advantages and disadvantages of each produced mesh in this study. Copyright © 2016 Elsevier Ltd. All rights reserved.
A tuned mesh-generation strategy for image representation based on data-dependent triangulation.
Li, Ping; Adams, Michael D
2013-05-01
A mesh-generation framework for image representation based on data-dependent triangulation is proposed. The proposed framework is a modified version of the frameworks of Rippa and Garland and Heckbert that facilitates the development of more effective mesh-generation methods. As the proposed framework has several free parameters, the effects of different choices of these parameters on mesh quality are studied, leading to the recommendation of a particular set of choices for these parameters. A mesh-generation method is then introduced that employs the proposed framework with these best parameter choices. This method is demonstrated to produce meshes of higher quality (both in terms of squared error and subjectively) than those generated by several competing approaches, at a relatively modest computational and memory cost.
Summary on Several Key Techniques in 3D Geological Modeling
2014-01-01
Several key techniques in 3D geological modeling including planar mesh generation, spatial interpolation, and surface intersection are summarized in this paper. Note that these techniques are generic and widely used in various applications but play a key role in 3D geological modeling. There are two essential procedures in 3D geological modeling: the first is the simulation of geological interfaces using geometric surfaces and the second is the building of geological objects by means of various geometric computations such as the intersection of surfaces. Discrete geometric surfaces that represent geological interfaces can be generated by creating planar meshes first and then spatially interpolating; those surfaces intersect and then form volumes that represent three-dimensional geological objects such as rock bodies. In this paper, the most commonly used algorithms of the key techniques in 3D geological modeling are summarized. PMID:24772029
Analysis of the vibratory excitation arising from spiral bevel gears
NASA Technical Reports Server (NTRS)
Mark, William D.
1987-01-01
Tools required to understand and predict in terms of its underlying causes the vibratory excitation arising from meshing spiral bevel gears are developed. A generalized three component transmission error of meshing spiral bevel gears is defined. Equations are derived that yield the three components of the generalized transmission error in terms of deviations of tooth running surfaces from equispaced perfect spherical involute surfaces and tooth/gearbody elastic deformations arising from the three components of the generalized force transmitted by the meshing gears. A method for incorporating these equations into the equations of motion of a gear system is described. Equations are derived for the three components of the generalized force transmitted by the gears which are valid whenever inertial effects of the meshing gears and their supports are negligible. Bearing offsets from the positions occupied by the shaft centerlines of perfect spherical involute bevel gears and bearing/bearing support flexibilities enter into the computation of these forces.
Puso, M. A.; Kokko, E.; Settgast, R.; ...
2014-10-22
An embedded mesh method using piecewise constant multipliers originally proposed by Puso et al. (CMAME, 2012) is analyzed here to determine effects of the pressure stabilization term and small cut cells. The approach is implemented for transient dynamics using the central difference scheme for the time discretization. It is shown that the resulting equations of motion are a stable linear system with a condition number independent of mesh size. Furthermore, we show that the constraints and the stabilization terms can be recast as non-proportional damping such that the time integration of the scheme is provably stable with a critical timemore » step computed from the undamped equations of motion. Effects of small cuts are discussed throughout the presentation. A mesh study is conducted to evaluate the effects of the stabilization on the discretization error and conditioning and is used to recommend an optimal value for stabilization scaling parameter. Several nonlinear problems are also analyzed and compared with comparable conforming mesh results. Finally, we show several demanding problems highlighting the robustness of the proposed approach.« less
Trends and topics in eye disease research in PubMed from 2010 to 2014.
Boudry, Christophe; Denion, Eric; Mortemousque, Bruno; Mouriaux, Fréderic
2016-01-01
The purpose of this study is to provide a report on scientific production during the period 2010-2014 in order to identify the major topics as well as the predominant actors (journals, countries, continents) involved in the field of eye disease. A PubMed search was carried out to extract articles related to eye diseases during the period 2010-2014. Data were downloaded and processed through developed PHP scripts for further analysis. A total of 62,123 articles were retrieved. A total of 3,368 different journals were found, and 19 journals were identified as "core journals" according to Braford's law. English was by far the predominant language. A total of 853,182 MeSH terms were found, representing an average of 13.73 (SD = 4.98) MeSH terms per article. Among these 853,182 MeSH terms, 14,689 different MeSH terms were identified. Vision Disorders, Glaucoma, Diabetic Retinopathy, Macular Degeneration, and Cataract were the most frequent five MeSH terms related to eye diseases. The analysis of the total number of publications showed that Europe and Asia were the most productive continents, and the USA and China the most productive countries. Interestingly, using the mean Five-Year Impact Factor, the two most productive continents were North America and Oceania. After adjustment for population, the overall ranking positions changed in favor of smaller countries (i.e. Iceland, Switzerland, Denmark, and New Zealand), while after adjustment for Gross Domestic Product (GDP), the overall ranking positions changed in favor of some developing countries (Malawi, Guatemala, Singapore). Due to the large number of articles included and the numerous parameters analyzed, this study provides a wide view of scientific productivity related to eye diseases during the period 2010-2014 and allows us to better understand this field.
Mesh Deformation Based on Fully Stressed Design: The Method and Two-Dimensional Examples
NASA Technical Reports Server (NTRS)
Hsu, Su-Yuen; Chang, Chau-Lyan
2007-01-01
Mesh deformation in response to redefined boundary geometry is a frequently encountered task in shape optimization and analysis of fluid-structure interaction. We propose a simple and concise method for deforming meshes defined with three-node triangular or four-node tetrahedral elements. The mesh deformation method is suitable for large boundary movement. The approach requires two consecutive linear elastic finite-element analyses of an isotropic continuum using a prescribed displacement at the mesh boundaries. The first analysis is performed with homogeneous elastic property and the second with inhomogeneous elastic property. The fully stressed design is employed with a vanishing Poisson s ratio and a proposed form of equivalent strain (modified Tresca equivalent strain) to calculate, from the strain result of the first analysis, the element-specific Young s modulus for the second analysis. The theoretical aspect of the proposed method, its convenient numerical implementation using a typical linear elastic finite-element code in conjunction with very minor extra coding for data processing, and results for examples of large deformation of two-dimensional meshes are presented in this paper. KEY WORDS: Mesh deformation, shape optimization, fluid-structure interaction, fully stressed design, finite-element analysis, linear elasticity, strain failure, equivalent strain, Tresca failure criterion
Gulzari, Usman Ali; Sajid, Muhammad; Anjum, Sheraz; Agha, Shahrukh; Torres, Frank Sill
2016-01-01
A Mesh topology is one of the most promising architecture due to its regular and simple structure for on-chip communication. Performance of mesh topology degraded greatly by increasing the network size due to small bisection width and large network diameter. In order to overcome this limitation, many researchers presented modified Mesh design by adding some extra links to improve its performance in terms of network latency and power consumption. The Cross-By-Pass-Mesh was presented by us as an improved version of Mesh topology by intelligent addition of extra links. This paper presents an efficient topology named Cross-By-Pass-Torus for further increase in the performance of the Cross-By-Pass-Mesh topology. The proposed design merges the best features of the Cross-By-Pass-Mesh and Torus, to reduce the network diameter, minimize the average number of hops between nodes, increase the bisection width and to enhance the overall performance of the network. In this paper, the architectural design of the topology is presented and analyzed against similar kind of 2D topologies in terms of average latency, throughput and power consumption. In order to certify the actual behavior of proposed topology, the synthetic traffic trace and five different real embedded application workloads are applied to the proposed as well as other competitor network topologies. The simulation results indicate that Cross-By-Pass-Torus is an efficient candidate among its predecessor's and competitor topologies due to its less average latency and increased throughput at a slight cost in network power and energy for on-chip communication.
CONSTRUCTION OF SCALAR AND VECTOR FINITE ELEMENT FAMILIES ON POLYGONAL AND POLYHEDRAL MESHES
GILLETTE, ANDREW; RAND, ALEXANDER; BAJAJ, CHANDRAJIT
2016-01-01
We combine theoretical results from polytope domain meshing, generalized barycentric coordinates, and finite element exterior calculus to construct scalar- and vector-valued basis functions for conforming finite element methods on generic convex polytope meshes in dimensions 2 and 3. Our construction recovers well-known bases for the lowest order Nédélec, Raviart-Thomas, and Brezzi-Douglas-Marini elements on simplicial meshes and generalizes the notion of Whitney forms to non-simplicial convex polygons and polyhedra. We show that our basis functions lie in the correct function space with regards to global continuity and that they reproduce the requisite polynomial differential forms described by finite element exterior calculus. We present a method to count the number of basis functions required to ensure these two key properties. PMID:28077939
CONSTRUCTION OF SCALAR AND VECTOR FINITE ELEMENT FAMILIES ON POLYGONAL AND POLYHEDRAL MESHES.
Gillette, Andrew; Rand, Alexander; Bajaj, Chandrajit
2016-10-01
We combine theoretical results from polytope domain meshing, generalized barycentric coordinates, and finite element exterior calculus to construct scalar- and vector-valued basis functions for conforming finite element methods on generic convex polytope meshes in dimensions 2 and 3. Our construction recovers well-known bases for the lowest order Nédélec, Raviart-Thomas, and Brezzi-Douglas-Marini elements on simplicial meshes and generalizes the notion of Whitney forms to non-simplicial convex polygons and polyhedra. We show that our basis functions lie in the correct function space with regards to global continuity and that they reproduce the requisite polynomial differential forms described by finite element exterior calculus. We present a method to count the number of basis functions required to ensure these two key properties.
Sadava, Emmanuel E; Krpata, David M; Gao, Yue; Rosen, Michael J; Novitsky, Yuri W
2014-01-01
In recent years, major advances have been accomplished in abdominal wall reconstruction. Introduction of newer prostheses have improved outcomes, but elimination of mesh-related morbidity is still an elusive issue. It is believed that host foreign body reaction to prosthesis plays an important role in the biology of these complications, so understanding of the molecular mechanisms behind mesh-tissue interactions may be a key for upcoming therapies. It appears that increasing biocompatibility of both synthetic prosthesis and biologic scaffolds might be the main avenues to achieve better outcomes. This manuscript provides an overview of major effectors of wound healing with particular emphasis on how their modulation might improve outcomes in tissue remodeling and mesh integration. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.
Hong, Guosong; Fu, Tian-Ming; Zhou, Tao; Schuhmann, Thomas G; Huang, Jinlin; Lieber, Charles M
2015-10-14
Syringe-injectable mesh electronics with tissue-like mechanical properties and open macroporous structures is an emerging powerful paradigm for mapping and modulating brain activity. Indeed, the ultraflexible macroporous structure has exhibited unprecedented minimal/noninvasiveness and the promotion of attractive interactions with neurons in chronic studies. These same structural features also pose new challenges and opportunities for precise targeted delivery in specific brain regions and quantitative input/output (I/O) connectivity needed for reliable electrical measurements. Here, we describe new results that address in a flexible manner both of these points. First, we have developed a controlled injection approach that maintains the extended mesh structure during the "blind" injection process, while also achieving targeted delivery with ca. 20 μm spatial precision. Optical and microcomputed tomography results from injections into tissue-like hydrogel, ex vivo brain tissue, and in vivo brains validate our basic approach and demonstrate its generality. Second, we present a general strategy to achieve up to 100% multichannel I/O connectivity using an automated conductive ink printing methodology to connect the mesh electronics and a flexible flat cable, which serves as the standard "plug-in" interface to measurement electronics. Studies of resistance versus printed line width were used to identify optimal conditions, and moreover, frequency-dependent noise measurements show that the flexible printing process yields values comparable to commercial flip-chip bonding technology. Our results address two key challenges faced by syringe-injectable electronics and thereby pave the way for facile in vivo applications of injectable mesh electronics as a general and powerful tool for long-term mapping and modulation of brain activity in fundamental neuroscience through therapeutic biomedical studies.
Exploiting MeSH indexing in MEDLINE to generate a data set for word sense disambiguation
2011-01-01
Background Evaluation of Word Sense Disambiguation (WSD) methods in the biomedical domain is difficult because the available resources are either too small or too focused on specific types of entities (e.g. diseases or genes). We present a method that can be used to automatically develop a WSD test collection using the Unified Medical Language System (UMLS) Metathesaurus and the manual MeSH indexing of MEDLINE. We demonstrate the use of this method by developing such a data set, called MSH WSD. Methods In our method, the Metathesaurus is first screened to identify ambiguous terms whose possible senses consist of two or more MeSH headings. We then use each ambiguous term and its corresponding MeSH heading to extract MEDLINE citations where the term and only one of the MeSH headings co-occur. The term found in the MEDLINE citation is automatically assigned the UMLS CUI linked to the MeSH heading. Each instance has been assigned a UMLS Concept Unique Identifier (CUI). We compare the characteristics of the MSH WSD data set to the previously existing NLM WSD data set. Results The resulting MSH WSD data set consists of 106 ambiguous abbreviations, 88 ambiguous terms and 9 which are a combination of both, for a total of 203 ambiguous entities. For each ambiguous term/abbreviation, the data set contains a maximum of 100 instances per sense obtained from MEDLINE. We evaluated the reliability of the MSH WSD data set using existing knowledge-based methods and compared their performance to that of the results previously obtained by these algorithms on the pre-existing data set, NLM WSD. We show that the knowledge-based methods achieve different results but keep their relative performance except for the Journal Descriptor Indexing (JDI) method, whose performance is below the other methods. Conclusions The MSH WSD data set allows the evaluation of WSD algorithms in the biomedical domain. Compared to previously existing data sets, MSH WSD contains a larger number of biomedical terms/abbreviations and covers the largest set of UMLS Semantic Types. Furthermore, the MSH WSD data set has been generated automatically reusing already existing annotations and, therefore, can be regenerated from subsequent UMLS versions. PMID:21635749
An efficient and robust 3D mesh compression based on 3D watermarking and wavelet transform
NASA Astrophysics Data System (ADS)
Zagrouba, Ezzeddine; Ben Jabra, Saoussen; Didi, Yosra
2011-06-01
The compression and watermarking of 3D meshes are very important in many areas of activity including digital cinematography, virtual reality as well as CAD design. However, most studies on 3D watermarking and 3D compression are done independently. To verify a good trade-off between protection and a fast transfer of 3D meshes, this paper proposes a new approach which combines 3D mesh compression with mesh watermarking. This combination is based on a wavelet transformation. In fact, the used compression method is decomposed to two stages: geometric encoding and topologic encoding. The proposed approach consists to insert a signature between these two stages. First, the wavelet transformation is applied to the original mesh to obtain two components: wavelets coefficients and a coarse mesh. Then, the geometric encoding is done on these two components. The obtained coarse mesh will be marked using a robust mesh watermarking scheme. This insertion into coarse mesh allows obtaining high robustness to several attacks. Finally, the topologic encoding is applied to the marked coarse mesh to obtain the compressed mesh. The combination of compression and watermarking permits to detect the presence of signature after a compression of the marked mesh. In plus, it allows transferring protected 3D meshes with the minimum size. The experiments and evaluations show that the proposed approach presents efficient results in terms of compression gain, invisibility and robustness of the signature against of many attacks.
Long-term results after artificial iris implantation in patients with aniridia.
Rickmann, Annekatrin; Szurman, Peter; Januschowski, Kai; Waizel, Maria; Spitzer, Martin S; Boden, Karl T; Szurman, Gesine B
2016-07-01
The custom-made, flexible artificial iris developed by HumanOptics and Koch can reconstruct the anterior segment of patients with aniridia. The aim of this study was to evaluate the long-term clinical outcome and complication spectrum after artificial iris implantation and the role of the embedded fiber mesh in view of specific complications. In this retrospective interventional case series, patients received an artificial iris between 2004 and 2013. Only eyes with a minimum follow-up period of 2 years were included. Indications were congenital, traumatic, or iatrogenic aniridia. The artificial iris was used either with or without embedded fiber mesh for partial or full prostheses. We included 34 patients (mean age 48.8 years; SD ±17.2) with a mean follow-up of 50.0 months (SD ±18.9 months). No repositioning of prostheses was necessary. In cases of keratopathy (17.6 %) visual function increased from baseline mean 1.6 logMAR (SD ±0.7) to 1.2 logMAR (SD ±0.7) after artificial iris implantation. The remaining iris tissue darkened during the follow-up in 23.5 % (83.3 % with and 10.7 % without mesh), 8.8 % developed glaucoma (50 % with and 0 % without mesh) and 14.7 % needed consecutive surgery after prostheses implantation (50 % with and 7.1 % without mesh). In three out of seven trauma cases (42.9 %) silicone oil was spilled into the anterior chamber after 2.5 years on average. The artificial iris prosthesis revealed a good clinical outcome in terms of long-term stability, cosmetic appearance, visual function, and represents a good functional iris diaphragm for compartmentalisation. Complications such as glaucoma, darkening of iris tissue, and need for consecutive anterior segment surgery are clearly associated with implants with integrated fiber mesh, but not to those without. Hence, the use of full iris prostheses without embedded fiber mesh, even in cases with remnant iris, and the use of slightly smaller implants than officially recommended may be beneficial.
Automated Patent Categorization and Guided Patent Search using IPC as Inspired by MeSH and PubMed.
Eisinger, Daniel; Tsatsaronis, George; Bundschus, Markus; Wieneke, Ulrich; Schroeder, Michael
2013-04-15
Document search on PubMed, the pre-eminent database for biomedical literature, relies on the annotation of its documents with relevant terms from the Medical Subject Headings ontology (MeSH) for improving recall through query expansion. Patent documents are another important information source, though they are considerably less accessible. One option to expand patent search beyond pure keywords is the inclusion of classification information: Since every patent is assigned at least one class code, it should be possible for these assignments to be automatically used in a similar way as the MeSH annotations in PubMed. In order to develop a system for this task, it is necessary to have a good understanding of the properties of both classification systems. This report describes our comparative analysis of MeSH and the main patent classification system, the International Patent Classification (IPC). We investigate the hierarchical structures as well as the properties of the terms/classes respectively, and we compare the assignment of IPC codes to patents with the annotation of PubMed documents with MeSH terms.Our analysis shows a strong structural similarity of the hierarchies, but significant differences of terms and annotations. The low number of IPC class assignments and the lack of occurrences of class labels in patent texts imply that current patent search is severely limited. To overcome these limits, we evaluate a method for the automated assignment of additional classes to patent documents, and we propose a system for guided patent search based on the use of class co-occurrence information and external resources.
Conceptual mapping of user's queries to medical subject headings.
Zieman, Y. L.; Bleich, H. L.
1997-01-01
This paper describes a way to map users' queries to relevant Medical Subject Headings (MeSH terms) used by the National Library of Medicine to index the biomedical literature. The method, called SENSE (SEarch with New SEmantics), transforms words and phrases in the users' queries into primary conceptual components and compares these components with those of the MeSH vocabulary. Similar to the way in which most numbers can be split into numerical factors and expressed as their product--for example, 42 can be expressed as 2*21, 6*7, 3*14, 2*3*7,--so most medical concepts can be split into "semantic factors" and expressed as their juxtaposition. Note that if we split 42 into its primary factors, the breakdown is unique: 2*3*7. Similarly, when we split medical concepts into their "primary semantic factors" the breakdown is also unique. For example, the MeSH term 'renovascular hypertension' can be split morphologically into reno, vascular, hyper, and tension--morphemes that can then be translated into their primary semantic factors--kidney, blood vessel, high, and pressure. By "factoring" each MeSH term in this way, and by similarly factoring the user's query, we can match query to MeSH term by searching for combinations of common factors. Unlike UMLS and other methods that match at the level of words or phrases, SENSE matches at the level of concepts; in this way, a wide variety of words and phrases that have the same meaning produce the same match. Now used in PaperChase, the method is surprisingly powerful in matching users' queries to Medical Subject Headings. PMID:9357680
Weintraub, A Y; Friedman, T; Baumfeld, Y; Neuman, M; Krissi, H
2015-12-01
The aim of this study was to assess patient-centered long term outcomes following anterior vaginal repair with mesh. In January 2015, we identified 124 women who underwent anterior pelvic floor repair with mesh between January 2006 and February 2009. Patient records were reviewed and demographic, clinical, intra-operative and post-operative follow-up data retrieved. Telephone interviews were conducted to access information on clinical outcomes. Associations between baseline characteristics and long term symptoms were assessed by multivariable logistic regression models. Seventy-nine women were reached and consented to participate. Patients were interviewed 79-104 months after surgery. Their mean age at the time of surgery was 62.48 ± 9.53 years; all had stage III cystocele with a mean POP Q point Ba of 5.32 ± 1.47. Twenty-four (30%) had a previous hysterectomy and 26 (33%) had a previous pelvic organ prolapse or stress urinary incontinence operation. At telephone interviews, recurrence of prolapse symptoms was reported by 11 (13.9%) patients, mostly in the posterior compartment. Only 6 needed a corrective procedure. One patient had her mesh removed due to dyspareunia. Eleven (13.9%) reported lower urinary tract symptoms other than prolapse, as follows: stress urinary incontinence (1), overactive bladder (8) and dyspareunia (2). Long term rates of recurrent prolapse, dyspareunia and lower urinary tract symptoms were low for patients who underwent anterior vaginal wall mesh augmentation surgery for symptomatic cystoceles. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
Automated Patent Categorization and Guided Patent Search using IPC as Inspired by MeSH and PubMed
2013-01-01
Document search on PubMed, the pre-eminent database for biomedical literature, relies on the annotation of its documents with relevant terms from the Medical Subject Headings ontology (MeSH) for improving recall through query expansion. Patent documents are another important information source, though they are considerably less accessible. One option to expand patent search beyond pure keywords is the inclusion of classification information: Since every patent is assigned at least one class code, it should be possible for these assignments to be automatically used in a similar way as the MeSH annotations in PubMed. In order to develop a system for this task, it is necessary to have a good understanding of the properties of both classification systems. This report describes our comparative analysis of MeSH and the main patent classification system, the International Patent Classification (IPC). We investigate the hierarchical structures as well as the properties of the terms/classes respectively, and we compare the assignment of IPC codes to patents with the annotation of PubMed documents with MeSH terms. Our analysis shows a strong structural similarity of the hierarchies, but significant differences of terms and annotations. The low number of IPC class assignments and the lack of occurrences of class labels in patent texts imply that current patent search is severely limited. To overcome these limits, we evaluate a method for the automated assignment of additional classes to patent documents, and we propose a system for guided patent search based on the use of class co-occurrence information and external resources. PMID:23734562
Orenstein, Sean B; Saberski, Ean R; Kreutzer, Donald L; Novitsky, Yuri W
2012-08-01
While synthetic prosthetics have essentially become mandatory for hernia repair, mesh-induced chronic inflammation and scarring can lead to chronic pain and limited mobility. Mesh propensity to induce such adverse effects is likely related to the prosthetic's material, weight, and/or pore size. We aimed to compare histopathologic responses to various synthetic meshes after short- and long-term implantations in mice. Samples of macroporous polyester (Parietex [PX]), heavyweight microporous polypropylene (Trelex[TX]), midweight microporous polypropylene (ProLite[PL]), lightweight macroporous polypropylene (Ultrapro[UP]), and expanded polytetrafluoroethylene (DualMesh[DM]) were implanted subcutaneously in mice. Four and 12 wk post-implantation, meshes were assessed for inflammation, foreign body reaction (FBR), and fibrosis. All meshes induced varying levels of inflammatory responses. PX induced the greatest inflammatory response and marked FBR. DM induced moderate FBR and a strong fibrotic response with mesh encapsulation at 12 wk. UP and PL had the lowest FBR, however, UP induced a significant chronic inflammatory response. Although inflammation decreased slightly for TX, marked FBR was present throughout the study. Of the three polypropylene meshes, fibrosis was greatest for TX and slightly reduced for PL and UP. For UP and PL, there was limited fibrosis within each mesh pore. Polyester mesh induced the greatest FBR and lasting chronic inflammatory response. Likewise, marked fibrosis and encapsulation was seen surrounding ePTFE. Heavier polypropylene meshes displayed greater early and persistent fibrosis; the reduced-weight polypropylene meshes were associated with the least amount of fibrosis. Mesh pore size was inversely proportional to bridging fibrosis. Moreover, reduced-weight polypropylene meshes demonstrated the smallest FBR throughout the study. Overall, we demonstrated that macroporous, reduced-weight polypropylene mesh exhibited the highest degree of biocompatibility at sites of mesh implantation. Copyright © 2012 Elsevier Inc. All rights reserved.
Mesh Algorithms for PDE with Sieve I: Mesh Distribution
Knepley, Matthew G.; Karpeev, Dmitry A.
2009-01-01
We have developed a new programming framework, called Sieve, to support parallel numerical partial differential equation(s) (PDE) algorithms operating over distributed meshes. We have also developed a reference implementation of Sieve in C++ as a library of generic algorithms operating on distributed containers conforming to the Sieve interface. Sieve makes instances of the incidence relation, or arrows, the conceptual first-class objects represented in the containers. Further, generic algorithms acting on this arrow container are systematically used to provide natural geometric operations on the topology and also, through duality, on the data. Finally, coverings and duality are used to encode notmore » only individual meshes, but all types of hierarchies underlying PDE data structures, including multigrid and mesh partitions. In order to demonstrate the usefulness of the framework, we show how the mesh partition data can be represented and manipulated using the same fundamental mechanisms used to represent meshes. We present the complete description of an algorithm to encode a mesh partition and then distribute a mesh, which is independent of the mesh dimension, element shape, or embedding. Moreover, data associated with the mesh can be similarly distributed with exactly the same algorithm. The use of a high level of abstraction within the Sieve leads to several benefits in terms of code reuse, simplicity, and extensibility. We discuss these benefits and compare our approach to other existing mesh libraries.« less
Progressive simplification and transmission of building polygons based on triangle meshes
NASA Astrophysics Data System (ADS)
Li, Hongsheng; Wang, Yingjie; Guo, Qingsheng; Han, Jiafu
2010-11-01
Digital earth is a virtual representation of our planet and a data integration platform which aims at harnessing multisource, multi-resolution, multi-format spatial data. This paper introduces a research framework integrating progressive cartographic generalization and transmission of vector data. The progressive cartographic generalization provides multiple resolution data from coarse to fine as key scales and increments between them which is not available in traditional generalization framework. Based on the progressive simplification algorithm, the building polygons are triangulated into meshes and encoded according to the simplification sequence of two basic operations, edge collapse and vertex split. The map data at key scales and encoded increments between them are stored in a multi-resolution file. As the client submits requests to the server, the coarsest map is transmitted first and then the increments. After data decoding and mesh refinement the building polygons with more details will be visualized. Progressive generalization and transmission of building polygons is demonstrated in the paper.
Risk factors for bladder cancer: challenges of conducting a literature search using PubMed.
Joshi, Ashish; Preslan, Elicia
2011-04-01
The objective of this study was to assess the risk factors for bladder cancer using PubMed articles from January 2000 to December 2009. The study also aimed to describe the challenges encountered in the methodology of a literature search for bladder cancer risk factors using PubMed. Twenty-six categories of risk factors for bladder cancer were identified using the National Cancer Institute Web site and the Medical Subject Headings (MeSH) Web site. A total of 1,338 PubMed searches were run using the term "urinary bladder cancer" and a risk factor term (e.g., "cigarette smoking") and were screened to identify 260 articles for final analysis. The search strategy had an overall precision of 3.42 percent, relative recall of 12.64 percent, and an F-measure of 5.39 percent. Although search terms derived from MeSH had the highest overall precision and recall, the differences did not reach significance, which indicates that for generalized, free-text searches of the PubMed database, the searchers' own terms are generally as effective as MeSH terms.
Parallel Performance Optimizations on Unstructured Mesh-based Simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarje, Abhinav; Song, Sukhyun; Jacobsen, Douglas
2015-01-01
© The Authors. Published by Elsevier B.V. This paper addresses two key parallelization challenges the unstructured mesh-based ocean modeling code, MPAS-Ocean, which uses a mesh based on Voronoi tessellations: (1) load imbalance across processes, and (2) unstructured data access patterns, that inhibit intra- and inter-node performance. Our work analyzes the load imbalance due to naive partitioning of the mesh, and develops methods to generate mesh partitioning with better load balance and reduced communication. Furthermore, we present methods that minimize both inter- and intranode data movement and maximize data reuse. Our techniques include predictive ordering of data elements for higher cachemore » efficiency, as well as communication reduction approaches. We present detailed performance data when running on thousands of cores using the Cray XC30 supercomputer and show that our optimization strategies can exceed the original performance by over 2×. Additionally, many of these solutions can be broadly applied to a wide variety of unstructured grid-based computations.« less
Runge-Kutta discontinuous Galerkin method using a new type of WENO limiters on unstructured meshes
NASA Astrophysics Data System (ADS)
Zhu, Jun; Zhong, Xinghui; Shu, Chi-Wang; Qiu, Jianxian
2013-09-01
In this paper we generalize a new type of limiters based on the weighted essentially non-oscillatory (WENO) finite volume methodology for the Runge-Kutta discontinuous Galerkin (RKDG) methods solving nonlinear hyperbolic conservation laws, which were recently developed in [32] for structured meshes, to two-dimensional unstructured triangular meshes. The key idea of such limiters is to use the entire polynomials of the DG solutions from the troubled cell and its immediate neighboring cells, and then apply the classical WENO procedure to form a convex combination of these polynomials based on smoothness indicators and nonlinear weights, with suitable adjustments to guarantee conservation. The main advantage of this new limiter is its simplicity in implementation, especially for the unstructured meshes considered in this paper, as only information from immediate neighbors is needed and the usage of complicated geometric information of the meshes is largely avoided. Numerical results for both scalar equations and Euler systems of compressible gas dynamics are provided to illustrate the good performance of this procedure.
Gondal, Mohammed A; Sadullah, Muhammad S; Dastageer, Mohamed A; McKinley, Gareth H; Panchanathan, Divya; Varanasi, Kripa K
2014-08-27
Surfaces which possess extraordinary water attraction or repellency depend on surface energy, surface chemistry, and nano- and microscale surface roughness. Synergistic superhydrophilic-underwater superoleophobic surfaces were fabricated by spray deposition of nanostructured TiO2 on stainless steel mesh substrates. The coated meshes were then used to study gravity driven oil-water separation, where only the water from the oil-water mixture is allowed to permeate through the mesh. Oil-water separation efficiencies of up to 99% could be achieved through the coated mesh of pore sizes 50 and 100 μm, compared to no separation at all, that was observed in the case of uncoated meshes of the same material and pore sizes. An adsorbed water on the TiO2 coated surface, formation of a water-film between the wires that form the mesh and the underwater superoleophobicity of the structured surface are the key factors that contribute to the enhanced efficiency observed in oil-water separation. The nature of the oil-water separation process using this coated mesh (in which the mesh allows water to pass through the porous structure but resists wetting by the oil phase) minimizes the fouling of mesh so that the need for frequent replacement of the separating medium is reduced. The fabrication approach presented here can be applied for coating large surface areas and to develop a large-scale oil-water separation facility for oil-field applications and petroleum industries.
Macrophage polarization in response to ECM coated polypropylene mesh
Wolf, MT; Dearth, CL; Ranallo, CA; LoPresti, S; Carey, LE; Daly, KA; Brown, BN; Badylak, SF
2015-01-01
The host response to implanted biomaterials is a highly regulated process that influences device functionality and clinical outcome. Non-degradable biomaterials, such as knitted polypropylene mesh, frequently elicit a chronic foreign body reaction with resultant fibrosis. Previous studies have shown that an extracellular matrix (ECM) hydrogel coating of polypropylene mesh reduces the intensity of the foreign body reaction, though the mode of action is unknown. Macrophage participation plays a key role in the development of the foreign body reaction to biomaterials, and therefore the present study investigated macrophage polarization following mesh implantation. Spatiotemporal analysis of macrophage polarization was conducted in response to uncoated polypropylene mesh and mesh coated with hydrated and dry forms of ECM hydrogels derived from either dermis or urinary bladder. Pro-inflammatory M1 macrophages (CD86+/CD68+), alternatively activated M2 macrophages (CD206+/CD68+), and foreign body giant cells were quantified between 3-35 days. Uncoated polypropylene mesh elicited a dominant M1 response at the mesh fiber surface, which was decreased by each ECM coating type beginning at 7 days. The diminished M1 response was accompanied by a reduction in the number of foreign body giant cells at 14 and 35 days, though there was a minimal effect upon the number of M2 macrophages at any time. These results show that ECM coatings attenuate the M1 macrophage response and increase the M2/M1 ratio to polypropylene mesh in vivo. PMID:24856104
Search and Graph Database Technologies for Biomedical Semantic Indexing: Experimental Analysis.
Segura Bedmar, Isabel; Martínez, Paloma; Carruana Martín, Adrián
2017-12-01
Biomedical semantic indexing is a very useful support tool for human curators in their efforts for indexing and cataloging the biomedical literature. The aim of this study was to describe a system to automatically assign Medical Subject Headings (MeSH) to biomedical articles from MEDLINE. Our approach relies on the assumption that similar documents should be classified by similar MeSH terms. Although previous work has already exploited the document similarity by using a k-nearest neighbors algorithm, we represent documents as document vectors by search engine indexing and then compute the similarity between documents using cosine similarity. Once the most similar documents for a given input document are retrieved, we rank their MeSH terms to choose the most suitable set for the input document. To do this, we define a scoring function that takes into account the frequency of the term into the set of retrieved documents and the similarity between the input document and each retrieved document. In addition, we implement guidelines proposed by human curators to annotate MEDLINE articles; in particular, the heuristic that says if 3 MeSH terms are proposed to classify an article and they share the same ancestor, they should be replaced by this ancestor. The representation of the MeSH thesaurus as a graph database allows us to employ graph search algorithms to quickly and easily capture hierarchical relationships such as the lowest common ancestor between terms. Our experiments show promising results with an F1 of 69% on the test dataset. To the best of our knowledge, this is the first work that combines search and graph database technologies for the task of biomedical semantic indexing. Due to its horizontal scalability, ElasticSearch becomes a real solution to index large collections of documents (such as the bibliographic database MEDLINE). Moreover, the use of graph search algorithms for accessing MeSH information could provide a support tool for cataloging MEDLINE abstracts in real time. ©Isabel Segura Bedmar, Paloma Martínez, Adrián Carruana Martín. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 01.12.2017.
Kelly, Michelle; Macdougall, Katherine; Olabisi, Oluwafisayo; McGuire, Neil
2017-02-01
Polypropylene is a material that is commonly used to treat pelvic floor conditions such as pelvic organ prolapse (POP) and stress urinary incontinence (SUI). Owing to the nature of complications experienced by some patients implanted with either incontinence or prolapse meshes, the biocompatibility of polypropylene has recently been questioned. This literature review considers the in vivo response to polypropylene following implantation in animal models. The specific areas explored in this review are material selection, impact of anatomical location, and the structure, weight and size of polypropylene mesh types. All relevant abstracts from original articles investigating the host response of mesh in vivo were reviewed. Papers were obtained and categorised into various mesh material types: polypropylene, polypropylene composites, and other synthetic and biologically derived mesh. Polypropylene mesh fared well in comparison with other material types in terms of host response. It was found that a lightweight, large-pore mesh is the most appropriate structure. The evidence reviewed shows that polypropylene evokes a less inflammatory or similar host response when compared with other materials used in mesh devices.
Research Trend Visualization by MeSH Terms from PubMed.
Yang, Heyoung; Lee, Hyuck Jai
2018-05-30
Motivation : PubMed is a primary source of biomedical information comprising search tool function and the biomedical literature from MEDLINE which is the US National Library of Medicine premier bibliographic database, life science journals and online books. Complimentary tools to PubMed have been developed to help the users search for literature and acquire knowledge. However, these tools are insufficient to overcome the difficulties of the users due to the proliferation of biomedical literature. A new method is needed for searching the knowledge in biomedical field. Methods : A new method is proposed in this study for visualizing the recent research trends based on the retrieved documents corresponding to a search query given by the user. The Medical Subject Headings (MeSH) are used as the primary analytical element. MeSH terms are extracted from the literature and the correlations between them are calculated. A MeSH network, called MeSH Net, is generated as the final result based on the Pathfinder Network algorithm. Results : A case study for the verification of proposed method was carried out on a research area defined by the search query (immunotherapy and cancer and "tumor microenvironment"). The MeSH Net generated by the method is in good agreement with the actual research activities in the research area (immunotherapy). Conclusion : A prototype application generating MeSH Net was developed. The application, which could be used as a "guide map for travelers", allows the users to quickly and easily acquire the knowledge of research trends. Combination of PubMed and MeSH Net is expected to be an effective complementary system for the researchers in biomedical field experiencing difficulties with search and information analysis.
Tam, Vernissia; Luketich, James D; Levy, Ryan M; Christie, Neil A; Awais, Omar; Shende, Manisha; Nason, Katie S
2017-10-01
Equipoise still exists regarding routine mesh cruroplasty during laparoscopic paraesophageal hernia (PEH). We aimed to determine whether selective mesh cruroplasty is associated with differences in recurrence and patient-reported outcomes. We compared symptom outcomes (n = 688) and radiographic recurrences (n = 101; at least 10% [or 2 cm] of stomach above hiatus) for 795 non-emergent PEH repair with fundoplication (n = 106 with mesh). Heartburn, regurgitation, epigastric pain, and anti-reflux medication use decreased significantly in both groups while postoperative dysphagia (mesh; p = 0.14), and bloating (non-mesh; p = 0.32), were unchanged. Radiographic recurrence rates were similar (15 mesh [22%] versus 86 non-mesh [17%]; p = 0.32; median 27 [IQR 14, 53] months), but was associated with surgical dissatisfaction (13% vs 4%; p = 0.007). Selective mesh cruroplasty was not associated with differences in symptom outcomes or radiographic recurrence rates during laparoscopic PEH repair. Radiographic recurrence was associated with dissatisfaction, emphasizing the need for continued focus on reducing recurrences. Copyright © 2017. Published by Elsevier Inc.
Kabirzadeh, Azar; Siamian, Hasan; Abadi, Ebrahim Bagherian Farah; Saravi, Benyamin Mohseni
2013-01-01
NONE DECLARED. Keywords are the most important tools for Information retrieval. They are usually used for retrieval of articles based on contents of information reserved from printed and electronic resources. Retrieval of appropriate keywords from Medical Subject Headings (MeSH) can impact with exact, correctness and short time on information retrieval. Regarding the above mentioned matters, this study was done to compare the Latin keywords was in the articles published in the Journal of Mazandaran University of Medical Sciences. This is a descriptive study. The data were extracted from the key words of Englsih abstracts of articles published in the years 2009-2010 in the Journal of Mazandaran University of Medical Sciences by census method. Checklist of data collection is designed, based on research objectives and literature review which has face validity. Compliance rate in this study was to determine if the keywords cited in this article as a full subject of the main subject headings in a MeSH (Bold and the selected word) is a perfect adjustment. If keywords were cited in the article but the main heading is not discussed in the following main topics to be discussed with reference to See and See related it has considered has partial adjustment. Out of 148 articles published in 12 issues in proposed time of studying, 72 research papers were analyzed. The average numbers of authors in each article were 4 ± 1. Results showed that most of specialty papers 42 (58. 4%), belonging to the (Department of Clinical Sciences) School of Medicine, 11 (15.3%) Basic Science, 6(8.4%) Pharmacy, Nursing and Midwifery 5(6.9%), 4(5.5%) Health, paramedical Sciences 3(4.2%), and non medical article 1(1.3%) school of medicine. In general, results showed that 80 (30%) of key words have been used to complete the adjustment. Also, only 1(1.4%) had complete adjustment with all the MeSH key words and in 8 articles(11.4%) key words of had no adjustment with MeSH. The results showed that only 17 articles could be retrieved if the search words are selected from the MeSH. In this case the expected 100% of published articles titles at this university the validity of exchange of research projects which is something noteworthy. The lack of correlation between number of authors and matching of Keywords with MeSH, may mean all of the papers' authors did not take part in writing and it is understanding that only one author wrote the paper.
Mesh-type acoustic vector sensor
NASA Astrophysics Data System (ADS)
Zalalutdinov, M. K.; Photiadis, D. M.; Szymczak, W. G.; McMahon, J. W.; Bucaro, J. A.; Houston, B. H.
2017-07-01
Motivated by the predictions of a theoretical model developed to describe the acoustic flow force exerted on closely spaced nano-fibers in a viscous medium, we have demonstrated a novel concept for a particle velocity-based directional acoustic sensor. The central element of the concept exploits the acoustically induced normal displacement of a fine mesh as a measure of the collinear projection of the particle velocity in the sound wave. The key observations are (i) the acoustically induced flow force on an individual fiber within the mesh is nearly independent of the fiber diameter and (ii) the mesh-flow interaction can be well-described theoretically by a nearest neighbor coupling approximation. Scaling arguments based on these two observations indicate that the refinement of the mesh down to the nanoscale leads to significant improvements in performance. The combination of the two dimensional nature of the mesh together with the nanoscale dimensions provides a dramatic gain in the total length of fiber exposed to the flow, leading to a sensitivity enhancement by orders of magnitude. We describe the fabrication of a prototype mesh sensor equipped with optical readout. Preliminary measurements carried out over a considerable bandwidth together with the results of numerical simulations are in good agreement with the theory, thus providing a proof of concept.
Safdari, Reza; Shahmoradi, Leila; Hosseini-Beheshti, Molouk-Sadat; Nejad, Ahmadreza Farzaneh; Hosseiniravandi, Mohammad
2015-10-01
Encyclopedias and their compilation have become so prevalent as a valid cultural medium in the world. The daily development of computer industry and the expansion of various sciences have made indispensable the compilation of electronic, specialized encyclopedias, especially the web-based ones. This is an applied-developmental study conducted in 2014. First, the main terms in the field of medical informatics were gathered using MeSH Online 2014 and the supplementary terms of each were determined, and then the tree diagram of the terms was drawn based on their relationship in MeSH. Based on the studies done by the researchers, the tree diagram of the encyclopedia was drawn with respect to the existing areas in this field, and the terms gathered were put in related domains. In MeSH, 75 preferred terms together with 249 supplementary ones were indexed. One of the informatics' sub-branches is biomedical informatics and health which itself consists of three sub-divisions of bioinformatics, clinical informatics, and health informatics. Medical informatics which is a subdivision of clinical informatics has developed from the three fields of medical sciences, management and social sciences, and computational sciences and mathematics. Medical Informatics is created of confluence and fusion and applications of the three major scientific branches include health and biological sciences, social sciences and management sciences, computing and mathematical sciences, and according to that the structure of MeSH is weak for future development of Encyclopedia of Medical Informatics.
Hinton, Elizabeth G; Oelschlegel, Sandra; Vaughn, Cynthia J; Lindsay, J Michael; Hurst, Sachiko M; Earl, Martha
2013-01-01
This study utilizes an informatics tool to analyze a robust literature search service in an academic medical center library. Structured interviews with librarians were conducted focusing on the benefits of such a tool, expectations for performance, and visual layout preferences. The resulting application utilizes Microsoft SQL Server and .Net Framework 3.5 technologies, allowing for the use of a web interface. Customer tables and MeSH terms are included. The National Library of Medicine MeSH database and entry terms for each heading are incorporated, resulting in functionality similar to searching the MeSH database through PubMed. Data reports will facilitate analysis of the search service.
LIMSI @ 2014 Clinical Decision Support Track
2014-11-01
MeSH and BoW runs) was based on the automatic generation of disease hypotheses for which we used data from OrphaNet [4] and the Disease Symptom Knowledge...with the MeSH terms of the top 5 disease hypotheses generated for the case reports. Compared to the other participants we achieved low scores...clinical question types. Query expansion (for both MeSH and BoW runs) was based on the automatic generation of disease hypotheses for which we used data
Sayer, T; Lim, J; Gauld, J M; Hinoul, P; Jones, P; Franco, N; Van Drie, D; Slack, M
2012-04-01
This study was designed to evaluate clinical outcomes ≥2 years following surgery with polypropylene mesh and vaginal support device (VSD) in women with vaginal prolapse, in a prospective, multi-center setting. Patients re-consented for this extended follow-up (n = 110), with anatomic evaluation using Pelvic Organ Prolapse Quantification (POP-Q) and validated questionnaires to assess pelvic symptoms and sexual function. Complications were recorded (safety set; n = 121). Median length of follow-up was 29 months (range 24-34 months). The primary anatomic success, defined as POP-Q 0-I, was 69.1%; however, in 84.5% of the cases, the leading vaginal edge was above the hymen. Pelvic symptoms and sexual function improved significantly from baseline (p < 0.01). Mesh exposure rate was 9.1%. Five percent reported stress urinary incontinence and 3.3% required further prolapse surgery. These results indicate this non-anchored mesh repair is a safe and effective treatment for women with symptomatic vaginal prolapse in the medium term.
A comparative study on different methods of automatic mesh generation of human femurs.
Viceconti, M; Bellingeri, L; Cristofolini, L; Toni, A
1998-01-01
The aim of this study was to evaluate comparatively five methods for automating mesh generation (AMG) when used to mesh a human femur. The five AMG methods considered were: mapped mesh, which provides hexahedral elements through a direct mapping of the element onto the geometry; tetra mesh, which generates tetrahedral elements from a solid model of the object geometry; voxel mesh which builds cubic 8-node elements directly from CT images; and hexa mesh that automatically generated hexahedral elements from a surface definition of the femur geometry. The various methods were tested against two reference models: a simplified geometric model and a proximal femur model. The first model was useful to assess the inherent accuracy of the meshes created by the AMG methods, since an analytical solution was available for the elastic problem of the simplified geometric model. The femur model was used to test the AMG methods in a more realistic condition. The femoral geometry was derived from a reference model (the "standardized femur") and the finite element analyses predictions were compared to experimental measurements. All methods were evaluated in terms of human and computer effort needed to carry out the complete analysis, and in terms of accuracy. The comparison demonstrated that each tested method deserves attention and may be the best for specific situations. The mapped AMG method requires a significant human effort but is very accurate and it allows a tight control of the mesh structure. The tetra AMG method requires a solid model of the object to be analysed but is widely available and accurate. The hexa AMG method requires a significant computer effort but can also be used on polygonal models and is very accurate. The voxel AMG method requires a huge number of elements to reach an accuracy comparable to that of the other methods, but it does not require any pre-processing of the CT dataset to extract the geometry and in some cases may be the only viable solution.
Publication trends in the medical informatics literature: 20 years of "Medical Informatics" in MeSH
2009-01-01
Background The purpose of this study is to identify publication output, and research areas, as well as descriptively and quantitatively characterize the field of medical informatics through publication trend analysis over a twenty year period (1987–2006). Methods A bibliometric analysis of medical informatics citations indexed in Medline was performed using publication trends, journal frequency, impact factors, MeSH term frequencies and characteristics of citations. Results There were 77,023 medical informatics articles published during this 20 year period in 4,644 unique journals. The average annual article publication growth rate was 12%. The 50 identified medical informatics MeSH terms are rarely assigned together to the same document and are almost exclusively paired with a non-medical informatics MeSH term, suggesting a strong interdisciplinary trend. Trends in citations, journals, and MeSH categories of medical informatics output for the 20-year period are summarized. Average impact factor scores and weighted average impact factor scores increased over the 20-year period with two notable growth periods. Conclusion There is a steadily growing presence and increasing visibility of medical informatics literature over the years. Patterns in research output that seem to characterize the historic trends and current components of the field of medical informatics suggest it may be a maturing discipline, and highlight specific journals in which the medical informatics literature appears most frequently, including general medical journals as well as informatics-specific journals. PMID:19159472
Safety of Synthetic Glue Used for Laparoscopic Prolapse Treatment.
Sarasa Castelló, Núria; Toth, Alexandra; Canis, Michel; Botchorishvilli, Revaz
2017-12-29
We detected mesh erosion and serious postoperative complications in 3 women after performing laparoscopic promontofixation (LPF) using glue for mesh fixation. Glue, largely used in hernia surgery repair, is proposed by some gynecologic surgeons because it saves time and is easier to use than traditional sutures. We report 3 cases of postoperative complications after LPF in which glue had been used and provide research in the published literature about the use of glue in LPF. A research of glue use in gynecology mesh fixation was performed through PubMed on October 2016. The search was done using the Medical Subject Heading terms "POP" & "Laparoscopy" & "surgical Mesh" and the word either "glue" or "adhesive. Only 2 articles were found: Willecocq et al [1] and Estrade et al [2]. Neither study focused on postoperative complications. In this publication, we accurately edited video surgeries with an instructive purpose. University Hospital of Clermont-Ferrand, France. Patient A, a 65-year-old woman, complained of pelvic pain and vaginal discharge 1 month after LPF (polypropylene mesh and glue had been used). Wall mesh exposure and purulent discharge were noted. She received antibiotics and underwent mesh ablation surgery; debris of the glue was easily identified. Patient B, a 65-year-old lady with previous hysterectomy consulted for a bulging feeling in her vagina (classification: cystocele +2; rectocele +3 stage). An LPF was performed using polypropylene soft nonabsorbable mesh and glue. One month later, an apical defect of vaginal epithelialization was detected; she received long estrogenic local treatment but had to undergo surgery when presenting malodorous discharge and mesh exposure. The exposed mesh was removed, and pieces of glue were identified, having avoided mesh attachment. Patient C had a previous abdominal hysterectomy and promontofixation using a polyester mesh with glue. She consulted to us for vaginal mesh erosion covered with purulent discharge 3.5 years after LPF in another center. At the surgery, 1 cm of the prosthesis was identified in the vagina, dissected, and sutured. One year later, she consulted for dyspareunia and purulent discharge; vaginal rigid mesh exposure with an epithelization defect and inflammatory signs was seen. During laparoscopy, prosthetic exposition and glue debris on the prosthesis were identified. In all 3 cases, debris of glue were identified in the no integrated mesh area. The suggested reasons of exposure can be the excessive amount of surgical glue applied. Moreover, a large amount of glue may be impairing tissue ingrowth through the mesh pores, causing low fibrosis and poor tissue integration [3]. Glue seems to prevent fibrosis from occurring. Its use in pelvic organ prolapse laparoscopic mesh fixation should be done with caution. No prospective studies reporting long-term comorbidities and results have been published. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.
The complete digital workflow in fixed prosthodontics: a systematic review.
Joda, Tim; Zarone, Fernando; Ferrari, Marco
2017-09-19
The continuous development in dental processing ensures new opportunities in the field of fixed prosthodontics in a complete virtual environment without any physical model situations. The aim was to compare fully digitalized workflows to conventional and/or mixed analog-digital workflows for the treatment with tooth-borne or implant-supported fixed reconstructions. A PICO strategy was executed using an electronic (MEDLINE, EMBASE, Google Scholar) plus manual search up to 2016-09-16 focusing on RCTs investigating complete digital workflows in fixed prosthodontics with regard to economics or esthetics or patient-centered outcomes with or without follow-up or survival/success rate analysis as well as complication assessment of at least 1 year under function. The search strategy was assembled from MeSH-Terms and unspecific free-text words: {(("Dental Prosthesis" [MeSH]) OR ("Crowns" [MeSH]) OR ("Dental Prosthesis, Implant-Supported" [MeSH])) OR ((crown) OR (fixed dental prosthesis) OR (fixed reconstruction) OR (dental bridge) OR (implant crown) OR (implant prosthesis) OR (implant restoration) OR (implant reconstruction))} AND {("Computer-Aided Design" [MeSH]) OR ((digital workflow) OR (digital technology) OR (computerized dentistry) OR (intraoral scan) OR (digital impression) OR (scanbody) OR (virtual design) OR (digital design) OR (cad/cam) OR (rapid prototyping) OR (monolithic) OR (full-contour))} AND {("Dental Technology" [MeSH) OR ((conventional workflow) OR (lost-wax-technique) OR (porcelain-fused-to-metal) OR (PFM) OR (implant impression) OR (hand-layering) OR (veneering) OR (framework))} AND {(("Study, Feasibility" [MeSH]) OR ("Survival" [MeSH]) OR ("Success" [MeSH]) OR ("Economics" [MeSH]) OR ("Costs, Cost Analysis" [MeSH]) OR ("Esthetics, Dental" [MeSH]) OR ("Patient Satisfaction" [MeSH])) OR ((feasibility) OR (efficiency) OR (patient-centered outcome))}. Assessment of risk of bias in selected studies was done at a 'trial level' including random sequence generation, allocation concealment, blinding, completeness of outcome data, selective reporting, and other bias using the Cochrane Collaboration tool. A judgment of risk of bias was assigned if one or more key domains had a high or unclear risk of bias. An official registration of the systematic review was not performed. The systematic search identified 67 titles, 32 abstracts thereof were screened, and subsequently, three full-texts included for data extraction. Analysed RCTs were heterogeneous without follow-up. One study demonstrated that fully digitally produced dental crowns revealed the feasibility of the process itself; however, the marginal precision was lower for lithium disilicate (LS2) restorations (113.8 μm) compared to conventional metal-ceramic (92.4 μm) and zirconium dioxide (ZrO2) crowns (68.5 μm) (p < 0.05). Another study showed that leucite-reinforced glass ceramic crowns were esthetically favoured by the patients (8/2 crowns) and clinicians (7/3 crowns) (p < 0.05). The third study investigated implant crowns. The complete digital workflow was more than twofold faster (75.3 min) in comparison to the mixed analog-digital workflow (156.6 min) (p < 0.05). No RCTs could be found investigating multi-unit fixed dental prostheses (FDP). The number of RCTs testing complete digital workflows in fixed prosthodontics is low. Scientifically proven recommendations for clinical routine cannot be given at this time. Research with high-quality trials seems to be slower than the industrial progress of available digital applications. Future research with well-designed RCTs including follow-up observation is compellingly necessary in the field of complete digital processing.
Research on regional numerical weather prediction
NASA Technical Reports Server (NTRS)
Kreitzberg, C. W.
1976-01-01
Extension of the predictive power of dynamic weather forecasting to scales below the conventional synoptic or cyclonic scales in the near future is assessed. Lower costs per computation, more powerful computers, and a 100 km mesh over the North American area (with coarser mesh extending beyond it) are noted at present. Doubling the resolution even locally (to 50 km mesh) would entail a 16-fold increase in costs (including vertical resolution and halving the time interval), and constraints on domain size and length of forecast. Boundary conditions would be provided by the surrounding 100 km mesh, and time-varying lateral boundary conditions can be considered to handle moving phenomena. More physical processes to treat, more efficient numerical techniques, and faster computers (improved software and hardware) backing up satellite and radar data could produce further improvements in forecasting in the 1980s. Boundary layer modeling, initialization techniques, and quantitative precipitation forecasting are singled out among key tasks.
Adaptive mesh refinement and load balancing based on multi-level block-structured Cartesian mesh
NASA Astrophysics Data System (ADS)
Misaka, Takashi; Sasaki, Daisuke; Obayashi, Shigeru
2017-11-01
We developed a framework for a distributed-memory parallel computer that enables dynamic data management for adaptive mesh refinement and load balancing. We employed simple data structure of the building cube method (BCM) where a computational domain is divided into multi-level cubic domains and each cube has the same number of grid points inside, realising a multi-level block-structured Cartesian mesh. Solution adaptive mesh refinement, which works efficiently with the help of the dynamic load balancing, was implemented by dividing cubes based on mesh refinement criteria. The framework was investigated with the Laplace equation in terms of adaptive mesh refinement, load balancing and the parallel efficiency. It was then applied to the incompressible Navier-Stokes equations to simulate a turbulent flow around a sphere. We considered wall-adaptive cube refinement where a non-dimensional wall distance y+ near the sphere is used for a criterion of mesh refinement. The result showed the load imbalance due to y+ adaptive mesh refinement was corrected by the present approach. To utilise the BCM framework more effectively, we also tested a cube-wise algorithm switching where an explicit and implicit time integration schemes are switched depending on the local Courant-Friedrichs-Lewy (CFL) condition in each cube.
Synthetic vaginal mesh for pelvic organ prolapse.
Iglesia, Cheryl B
2011-10-01
The purpose of this review is to summarize recently published comparative trials on synthetic vaginal mesh versus traditional native tissue repairs for pelvic organ prolapse. Although studies suggest benefit from the use of synthetic vaginal mesh for anterior compartment prolapse, data are limited on the use of mesh for posterior and apical prolapse when compared with native tissue repair. The benefits of a more durable repair must be weighed against risks such as the development of de-novo stress incontinence, visceral injury, dyspareunia, pelvic pain and mesh contraction, exposure and extrusion requiring reoperation. Furthermore, the success rates of native tissue repairs are higher than previously considered using updated validated composite outcomes that incorporate both subjective relief of bulge and objective cure defined as prolapse above the hymenal ring. Surgeons placing synthetic mesh for pelvic organ prolapse should counsel patients regarding the potential benefits, risks, and alternatives including native tissue repairs. Level 1 evidence suggests anterior synthetic mesh may be superior to anterior repair. Expert opinion suggests potential benefit of vaginal mesh for recurrences, hysteropexy, and advanced prolapse in patients with medical co-morbidities precluding invasive open and endoscopic sacrocolpopexies; however, comparative clinical trials with long-term data are needed. (C) 2011 Lippincott Williams & Wilkins, Inc.
Emerging trend prediction in biomedical literature.
Moerchen, Fabian; Fradkin, Dmitriy; Dejori, Mathaeus; Wachmann, Bernd
2008-11-06
We present a study on how to predict new emerging trends in the biomedical domain based on textual data. We thereby propose a way of anticipating the transformation of arbitrary information into ground truth knowledge by predicting the inclusion of new terms into the MeSH ontology. We also discuss the preparation of a dataset for the evaluation of emerging trend prediction algorithms that is based on PubMed abstracts and related MeSH terms. The results suggest that early prediction of emerging trends is possible.
Tam, Vernissia; Winger, Daniel G.; Nason, Katie S.
2015-01-01
Structured Abstract Background Equipoise exists regarding whether mesh cruroplasty during laparoscopic large hiatal hernia repair improves symptomatic outcomes compared to suture repair. Data Source Systematic literature review (MEDLINE and EMBASE) identified 13 studies (1194 patients; 521 suture and 673 mesh) comparing mesh versus suture cruroplasty during laparoscopic repair of large hiatal hernia. We abstracted data regarding symptom assessment, objective recurrence, and reoperation and performed meta-analysis. Conclusions The majority of studies reported significant symptom improvement. Data were insufficient to evaluate symptomatic versus asymptomatic recurrence. Time to evaluation was skewed toward longer follow-up after suture cruroplasty. Odds of recurrence (OR 0.51, 95% CI 0.30–0.87; overall p=0.014) but not need for reoperation (OR 0.42, 95% CI 0.13–1.37; overall p=0.149) were less after mesh cruroplasty. Quality of evidence supporting routine use of mesh cruroplasty is low. Mesh should be used at surgeon discretion until additional studies evaluating symptomatic outcomes, quality of life and long-term recurrence are available. PMID:26520872
Adherence to ICCS nomenclature guidelines in subsequent literature: a bibliometric study.
Dannaway, Jasan; Ng, Heryanto; Deshpande, Aniruddh V
2013-09-01
Since the publication of the 2006 International Children's Continence Society (ICCS) guidelines on terminologies for lower urinary tract dysfunction in children, little is known of their impact. In this study, we aim to quantify the adherence to the guidelines in the published literature, and to examine whether Medical Subject Headings (MeSH) in MEDLINE reflect the recommended "new" ICCS terminology. Seven pairs of pre-specified paired terms (obsolete and recommended by the ICCS) were searched, limited to paediatric literature published between 2002 and 2010. Their use in the literature was compared between the pre-guideline (2002-2005) and post-guideline (2007-2010) period and across geographical regions. MeSH in MEDLINE were examined for the use of ICCS preferred terminology. Publications in paediatric urinary incontinence have shown a 49% increase from 2002-2005 to 2007-2010 (55-82 per year). There was about a fourfold increase in the likelihood of usage of ICCS recommended terminologies post ICCS guideline publication (OR: 4.19, 95% CI: 3.04-5.78, P < 0.001). Approximately 25% of the studies published between 2007 and 2010 used obsolete terminologies. Analysis indicated satisfactory uptake for most terms, with the exception of "urotherapy." There was no significant geographical variation in uptake. More than half of the ICCS-recommended terms (4/7) did not appear in the current MeSH indexing tree and scope notes. Overall uptake of recommended terms following release of ICCS terminology guidelines was encouraging although it remains suboptimal for certain terms. Efforts need to be made to improve the current MEDLINE indexing so that MeSH terms reflect terminology recommended by the ICCS. Copyright © 2012 Wiley Periodicals, Inc.
Automatic generation of endocardial surface meshes with 1-to-1 correspondence from cine-MR images
NASA Astrophysics Data System (ADS)
Su, Yi; Teo, S.-K.; Lim, C. W.; Zhong, L.; Tan, R. S.
2015-03-01
In this work, we develop an automatic method to generate a set of 4D 1-to-1 corresponding surface meshes of the left ventricle (LV) endocardial surface which are motion registered over the whole cardiac cycle. These 4D meshes have 1- to-1 point correspondence over the entire set, and is suitable for advanced computational processing, such as shape analysis, motion analysis and finite element modelling. The inputs to the method are the set of 3D LV endocardial surface meshes of the different frames/phases of the cardiac cycle. Each of these meshes is reconstructed independently from border-delineated MR images and they have no correspondence in terms of number of vertices/points and mesh connectivity. To generate point correspondence, the first frame of the LV mesh model is used as a template to be matched to the shape of the meshes in the subsequent phases. There are two stages in the mesh correspondence process: (1) a coarse matching phase, and (2) a fine matching phase. In the coarse matching phase, an initial rough matching between the template and the target is achieved using a radial basis function (RBF) morphing process. The feature points on the template and target meshes are automatically identified using a 16-segment nomenclature of the LV. In the fine matching phase, a progressive mesh projection process is used to conform the rough estimate to fit the exact shape of the target. In addition, an optimization-based smoothing process is used to achieve superior mesh quality and continuous point motion.
Safdari, Reza; Shahmoradi, Leila; Hosseini-beheshti, Molouk-sadat; Nejad, Ahmadreza Farzaneh; Hosseiniravandi, Mohammad
2015-01-01
Introduction: Encyclopedias and their compilation have become so prevalent as a valid cultural medium in the world. The daily development of computer industry and the expansion of various sciences have made indispensable the compilation of electronic, specialized encyclopedias, especially the web-based ones. Materials and Methods: This is an applied-developmental study conducted in 2014. First, the main terms in the field of medical informatics were gathered using MeSH Online 2014 and the supplementary terms of each were determined, and then the tree diagram of the terms was drawn based on their relationship in MeSH. Based on the studies done by the researchers, the tree diagram of the encyclopedia was drawn with respect to the existing areas in this field, and the terms gathered were put in related domains. Findings: In MeSH, 75 preferred terms together with 249 supplementary ones were indexed. One of the informatics’ sub-branches is biomedical informatics and health which itself consists of three sub-divisions of bioinformatics, clinical informatics, and health informatics. Medical informatics which is a subdivision of clinical informatics has developed from the three fields of medical sciences, management and social sciences, and computational sciences and mathematics. Results and Discussion: Medical Informatics is created of confluence and fusion and applications of the three major scientific branches include health and biological sciences, social sciences and management sciences, computing and mathematical sciences, and according to that the structure of MeSH is weak for future development of Encyclopedia of Medical Informatics. PMID:26635440
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yuzhou, E-mail: yuzhousun@126.com; Chen, Gensheng; Li, Dongxia
2016-06-08
This paper attempts to study the application of mesh-free method in the numerical simulations of the higher-order continuum structures. A high-order bending beam considers the effect of the third-order derivative of deflections, and can be viewed as a one-dimensional higher-order continuum structure. The moving least-squares method is used to construct the shape function with the high-order continuum property, the curvature and the third-order derivative of deflections are directly interpolated with nodal variables and the second- and third-order derivative of the shape function, and the mesh-free computational scheme is establish for beams. The coupled stress theory is introduced to describe themore » special constitutive response of the layered rock mass in which the bending effect of thin layer is considered. The strain and the curvature are directly interpolated with the nodal variables, and the mesh-free method is established for the layered rock mass. The good computational efficiency is achieved based on the developed mesh-free method, and some key issues are discussed.« less
Mapping proteins to disease terminologies: from UniProt to MeSH
Mottaz, Anaïs; Yip, Yum L; Ruch, Patrick; Veuthey, Anne-Lise
2008-01-01
Background Although the UniProt KnowledgeBase is not a medical-oriented database, it contains information on more than 2,000 human proteins involved in pathologies. However, these annotations are not standardized, which impairs the interoperability between biological and clinical resources. In order to make these data easily accessible to clinical researchers, we have developed a procedure to link diseases described in the UniProtKB/Swiss-Prot entries to the MeSH disease terminology. Results We mapped disease names extracted either from the UniProtKB/Swiss-Prot entry comment lines or from the corresponding OMIM entry to the MeSH. Different methods were assessed on a benchmark set of 200 disease names manually mapped to MeSH terms. The performance of the retained procedure in term of precision and recall was 86% and 64% respectively. Using the same procedure, more than 3,000 disease names in Swiss-Prot were mapped to MeSH with comparable efficiency. Conclusions This study is a first attempt to link proteins in UniProtKB to the medical resources. The indexing we provided will help clinicians and researchers navigate from diseases to genes and from genes to diseases in an efficient way. The mapping is available at: . PMID:18460185
Zhang, Yeshui; Nahil, Mohamad A; Wu, Chunfei; Williams, Paul T
2017-11-01
A stainless-steel mesh loaded with nickel catalyst was produced and used for the pyrolysis-catalysis of waste high-density polyethylene with the aim of producing high-value carbon products, including carbon nanotubes (CNTs). The catalysis temperature and plastic-to-catalyst ratio were investigated to determine the influence on the formation of different types of carbon deposited on the nickel-stainless-steel mesh catalyst. Increasing temperature from 700 to 900°C resulted in an increase in the carbon deposited on the nickel-loaded stainless-steel mesh catalyst from 32.5 to 38.0 wt%. The increase in sample-to-catalyst ratio reduced the amount of carbon deposited on the mesh catalyst in terms of g carbon g -1 plastic. The carbons were found to be largely composed of filamentous carbons, with negligible disordered (amorphous) carbons. Transmission electron microscopy analysis of the filamentous carbons revealed them to be composed of a large proportion (estimated at ∼40%) multi-walled carbon nanotubes (MWCNTs). The optimum process conditions for CNT production, in terms of yield and graphitic nature, determined by Raman spectroscopy, was catalysis temperature of 800°C and plastic-to-catalyst ratio of 1:2, where a mass of 334 mg of filamentous/MWCNTs g -1 plastic was produced.
Muench, Eugene V.
1971-01-01
A computerized English/Spanish correlation index to five biomedical library classification schemes and a computerized English/Spanish, Spanish/English listings of MeSH are described. The index was accomplished by supplying appropriate classification numbers of five classification schemes (National Library of Medicine; Library of Congress; Dewey Decimal; Cunningham; Boston Medical) to MeSH and a Spanish translation of MeSH The data were keypunched, merged on magnetic tape, and sorted in a computer alphabetically by English and Spanish subject headings and sequentially by classification number. Some benefits and uses of the index are: a complete index to classification schemes based on MeSH terms; a tool for conversion of classification numbers when reclassifying collections; a Spanish index and a crude Spanish translation of five classification schemes; a data base for future applications, e.g., automatic classification. Other classification schemes, such as the UDC, and translations of MeSH into other languages can be added. PMID:5172471
Medical Subject Headings (MeSH) for indexing and retrieving open-source healthcare data.
Marc, David T; Khairat, Saif S
2014-01-01
The US federal government initiated the Open Government Directive where federal agencies are required to publish high value datasets so that they are available to the public. Data.gov and the community site Healthdata.gov were initiated to disperse such datasets. However, data searches and retrieval for these sites are keyword driven and severely limited in performance. The purpose of this paper is to address the issue of extracting relevant open-source data by proposing a method of adopting the MeSH framework for indexing and data retrieval. A pilot study was conducted to compare the performance of traditional keywords to MeSH terms for retrieving relevant open-source datasets related to "mortality". The MeSH framework resulted in greater sensitivity with comparable specificity to the keyword search. MeSH showed promise as a method for indexing and retrieving data, yet future research should conduct a larger scale evaluation of the performance of the MeSH framework for retrieving relevant open-source healthcare datasets.
Facile Fabrication of a Polyethylene Mesh for Oil/Water Separation in a Complex Environment.
Zhao, Tianyi; Zhang, Dongmei; Yu, Cunming; Jiang, Lei
2016-09-14
Low cost, eco-friendly, and easily scaled-up processes are needed to fabricate efficient oil/water separation materials, especially those useful in harsh environments such as highly acidic, alkaline, and salty environments, to deal with serious oil spills and industrial organic pollutants. Herein, a highly efficient oil/water separation mesh with durable chemical stability was fabricated by simply scratching and pricking a conventional polyethylene (PE) film. Multiscaled morphologies were obtained by this scratching and pricking process and provided the mesh with a special wettability performance termed superhydrophobicity, superoleophilicity, and low water adhesion, while the inert chemical properties of PE delivered chemical etching resistance to the fabricated mesh. In addition to a highly efficient oil/corrosive liquid separation, the fabricated PE mesh was also reusable and exhibited ultrafast oil/water separation solely by gravity. The easy operation, chemical durability, reusability, and efficiency of the novel PE mesh give it high potential for use in industrial and consumer applications.
Budget of Turbulent Kinetic Energy in a Shock Wave Boundary-Layer Interaction
NASA Technical Reports Server (NTRS)
Vyas, Manan A.; Waindim, Mbu; Gaitonde, Datta V.
2016-01-01
Implicit large-eddy simulation (ILES) of a shock wave/boundary-layer interaction (SBLI) was performed. Quantities present in the exact equation of the turbulent kinetic energy transport were accumulated and used to calculate terms like production, dissipation, molecular diffusion, and turbulent transport. The present results for a turbulent boundary layer were validated by comparison with direct numerical simulation data. It was found that a longer development domain was necessary for the boundary layer to reach an equilibrium state and a finer mesh resolution would improve the predictions. In spite of these findings, trends of the present budget match closely with that of the direct numerical simulation. Budgets for the SBLI region are presented at key axial stations. These budgets showed interesting dynamics as the incoming boundary layer transforms and the terms of the turbulent kinetic energy budget change behavior within the interaction region.
Deiterding, Ralf
2011-01-01
Numerical simulation can be key to the understanding of the multidimensional nature of transient detonation waves. However, the accurate approximation of realistic detonations is demanding as a wide range of scales needs to be resolved. This paper describes a successful solution strategy that utilizes logically rectangular dynamically adaptive meshes. The hydrodynamic transport scheme and the treatment of the nonequilibrium reaction terms are sketched. A ghost fluid approach is integrated into the method to allow for embedded geometrically complex boundaries. Large-scale parallel simulations of unstable detonation structures of Chapman-Jouguet detonations in low-pressure hydrogen-oxygen-argon mixtures demonstrate the efficiency of the described techniquesmore » in practice. In particular, computations of regular cellular structures in two and three space dimensions and their development under transient conditions, that is, under diffraction and for propagation through bends are presented. Some of the observed patterns are classified by shock polar analysis, and a diagram of the transition boundaries between possible Mach reflection structures is constructed.« less
USDA-ARS?s Scientific Manuscript database
The objectives of this study were to characterize wireless sensor nodes that we developed in terms of power consumption and functionality, and compare the performance of mesh and non-mesh wireless sensor networks (WSNs) comprised mainly of infrared thermometer thermocouples located on a center pivot...
Rosen, Michael J.; Bauer, Joel J.; Harmaty, Marco; Carbonell, Alfredo M.; Cobb, William S.; Matthews, Brent; Goldblatt, Matthew I.; Selzer, Don J.; Poulose, Benjamin K.; Hansson, Bibi M. E.; Rosman, Camiel; Chao, James J.; Jacobsen, Garth R.
2017-01-01
Objective: The aim of the study was to evaluate biosynthetic absorbable mesh in single-staged contaminated (Centers for Disease Control class II and III) ventral hernia (CVH) repair over 24 months. Background: CVH has an increased risk of postoperative infection. CVH repair with synthetic or biologic meshes has reported chronic biomaterial infections and high hernia recurrence rates. Methods: Patients with a contaminated or clean-contaminated operative field and a hernia defect at least 9 cm2 had a biosynthetic mesh (open, sublay, retrorectus, or intraperitoneal) repair with fascial closure (n = 104). Endpoints included overall Kaplan-Meier estimates for hernia recurrence and postoperative wound infection rates at 24 months, and the EQ-5D and Short Form 12 Health Survey (SF-12). Analyses were conducted on the intent-to-treat population, and health outcome measures evaluated using paired t tests. Results: Patients had a mean age of 58 years, body mass index of 28 kg/m2, 77% had contaminated wounds, and 84% completed 24-months follow-up. Concomitant procedures included fistula takedown (n = 24) or removal of infected previously placed mesh (n = 29). Hernia recurrence rate was 17% (n = 16). At the time of CVH repair, intraperitoneal placement of the biosynthetic mesh significantly increased the risk of recurrences (P ≤ 0.04). Surgical site infections (19/104) led to higher risk of recurrence (P < 0.01). Mean 24-month EQ-5D (index and visual analogue) and SF-12 physical component and mental scores improved from baseline (P < 0.05). Conclusions: In this prospective longitudinal study, biosynthetic absorbable mesh showed efficacy in terms of long-term recurrence and quality of life for CVH repair patients and offers an alternative to biologic and permanent synthetic meshes in these complex situations. PMID:28009747
Silveira, Raquel Kelner; Domingie, Sophie; Kirzin, Sylvain; de Melo Filho, Djalma Agripino; Portier, Guillaume
2017-10-01
Ventral mesh rectopexy (VMR) is a surgical option to treat rectal prolapse with pelvic floor dysfunction (PFD). Using synthetic surgical glue to fix the mesh to the anterior rectal wall after ventral dissection could be advantageous in comparison with sutured or stapled fixation. This study aimed to evaluate the safety and efficacy of synthetic surgical glue for mesh fixation compared with suture mesh fixation in VMR. This observational cohort study is a retrospective analysis conducted in a University Hospital Pelvic Surgery Center. All consecutive female patients (n = 176) who underwent laparoscopic or laparotomic VMR between January 2009 and December 2014 were included. Two groups were defined based on mesh fixation technique of the rectal wall: VMR with synthetic glue (n = 66) and VMR with suture (n = 110). The recurrence-free survival after VMR was determined by Kaplan-Meier method and multivariate analysis by Cox regression. Short-term postoperative complications, postoperative symptom improvement, the need for complementary treatment postoperatively, and procedure length were evaluated. A total of 176 females patients (mean age, 58.6 ± 13.7 years) underwent VMR with synthetic mesh. Mean recurrence-free survivals after VMR were 17.16 (CI 95% 16.54-17.80) and 17.33 (CI 95% 16.89-17.77) months in the glue group and the suture group, respectively (p > 0.05). Cox regression identified an independent effect on the recurrence risk of the external rectal prolapse, alone, or in combination with other anatomical abnormalities (HR = 0.37; CI 95% 0.14-0.93; p = 0.03). There was no significant difference of short-term postoperative morbidity, procedure length, postoperative symptom improvement, or need for complementary treatment postoperatively between suture versus glue groups (all p > 0.05). Use of glue to fix the mesh in VMR was safe and had no impact on outcomes. External prolapse was the unique significant predictive factor for recurrence.
Balanced Central Schemes for the Shallow Water Equations on Unstructured Grids
NASA Technical Reports Server (NTRS)
Bryson, Steve; Levy, Doron
2004-01-01
We present a two-dimensional, well-balanced, central-upwind scheme for approximating solutions of the shallow water equations in the presence of a stationary bottom topography on triangular meshes. Our starting point is the recent central scheme of Kurganov and Petrova (KP) for approximating solutions of conservation laws on triangular meshes. In order to extend this scheme from systems of conservation laws to systems of balance laws one has to find an appropriate discretization of the source terms. We first show that for general triangulations there is no discretization of the source terms that corresponds to a well-balanced form of the KP scheme. We then derive a new variant of a central scheme that can be balanced on triangular meshes. We note in passing that it is straightforward to extend the KP scheme to general unstructured conformal meshes. This extension allows us to recover our previous well-balanced scheme on Cartesian grids. We conclude with several simulations, verifying the second-order accuracy of our scheme as well as its well-balanced properties.
Campbell, J Q; Coombs, D J; Rao, M; Rullkoetter, P J; Petrella, A J
2016-09-06
The purpose of this study was to seek broad verification and validation of human lumbar spine finite element models created using a previously published automated algorithm. The automated algorithm takes segmented CT scans of lumbar vertebrae, automatically identifies important landmarks and contact surfaces, and creates a finite element model. Mesh convergence was evaluated by examining changes in key output variables in response to mesh density. Semi-direct validation was performed by comparing experimental results for a single specimen to the automated finite element model results for that specimen with calibrated material properties from a prior study. Indirect validation was based on a comparison of results from automated finite element models of 18 individual specimens, all using one set of generalized material properties, to a range of data from the literature. A total of 216 simulations were run and compared to 186 experimental data ranges in all six primary bending modes up to 7.8Nm with follower loads up to 1000N. Mesh convergence results showed less than a 5% difference in key variables when the original mesh density was doubled. The semi-direct validation results showed that the automated method produced results comparable to manual finite element modeling methods. The indirect validation results showed a wide range of outcomes due to variations in the geometry alone. The studies showed that the automated models can be used to reliably evaluate lumbar spine biomechanics, specifically within our intended context of use: in pure bending modes, under relatively low non-injurious simulated in vivo loads, to predict torque rotation response, disc pressures, and facet forces. Copyright © 2016 Elsevier Ltd. All rights reserved.
MeSHLabeler: improving the accuracy of large-scale MeSH indexing by integrating diverse evidence.
Liu, Ke; Peng, Shengwen; Wu, Junqiu; Zhai, Chengxiang; Mamitsuka, Hiroshi; Zhu, Shanfeng
2015-06-15
Medical Subject Headings (MeSHs) are used by National Library of Medicine (NLM) to index almost all citations in MEDLINE, which greatly facilitates the applications of biomedical information retrieval and text mining. To reduce the time and financial cost of manual annotation, NLM has developed a software package, Medical Text Indexer (MTI), for assisting MeSH annotation, which uses k-nearest neighbors (KNN), pattern matching and indexing rules. Other types of information, such as prediction by MeSH classifiers (trained separately), can also be used for automatic MeSH annotation. However, existing methods cannot effectively integrate multiple evidence for MeSH annotation. We propose a novel framework, MeSHLabeler, to integrate multiple evidence for accurate MeSH annotation by using 'learning to rank'. Evidence includes numerous predictions from MeSH classifiers, KNN, pattern matching, MTI and the correlation between different MeSH terms, etc. Each MeSH classifier is trained independently, and thus prediction scores from different classifiers are incomparable. To address this issue, we have developed an effective score normalization procedure to improve the prediction accuracy. MeSHLabeler won the first place in Task 2A of 2014 BioASQ challenge, achieving the Micro F-measure of 0.6248 for 9,040 citations provided by the BioASQ challenge. Note that this accuracy is around 9.15% higher than 0.5724, obtained by MTI. The software is available upon request. © The Author 2015. Published by Oxford University Press.
MeSHLabeler: improving the accuracy of large-scale MeSH indexing by integrating diverse evidence
Liu, Ke; Peng, Shengwen; Wu, Junqiu; Zhai, Chengxiang; Mamitsuka, Hiroshi; Zhu, Shanfeng
2015-01-01
Motivation: Medical Subject Headings (MeSHs) are used by National Library of Medicine (NLM) to index almost all citations in MEDLINE, which greatly facilitates the applications of biomedical information retrieval and text mining. To reduce the time and financial cost of manual annotation, NLM has developed a software package, Medical Text Indexer (MTI), for assisting MeSH annotation, which uses k-nearest neighbors (KNN), pattern matching and indexing rules. Other types of information, such as prediction by MeSH classifiers (trained separately), can also be used for automatic MeSH annotation. However, existing methods cannot effectively integrate multiple evidence for MeSH annotation. Methods: We propose a novel framework, MeSHLabeler, to integrate multiple evidence for accurate MeSH annotation by using ‘learning to rank’. Evidence includes numerous predictions from MeSH classifiers, KNN, pattern matching, MTI and the correlation between different MeSH terms, etc. Each MeSH classifier is trained independently, and thus prediction scores from different classifiers are incomparable. To address this issue, we have developed an effective score normalization procedure to improve the prediction accuracy. Results: MeSHLabeler won the first place in Task 2A of 2014 BioASQ challenge, achieving the Micro F-measure of 0.6248 for 9,040 citations provided by the BioASQ challenge. Note that this accuracy is around 9.15% higher than 0.5724, obtained by MTI. Availability and implementation: The software is available upon request. Contact: zhusf@fudan.edu.cn PMID:26072501
Evidence-based outcomes for mesh-based surgery for pelvic organ prolapse.
Mettu, Jayadev R; Colaco, Marc; Badlani, Gopal H
2014-07-01
In light of all the recent controversy regarding the use of synthetic mesh for pelvic organ prolapse, we did a retrospective review of the evidence-based outcomes and complications for its use. A total of 18 of the most recent studies in the last 5 years were selected. Studies selected were prospective randomized or quasi-randomized controlled trials that included surgical operations for pelvic organ prolapse for this review. Additionally, Cochrane review and meta-analysis of outcomes and complication were also analyzed. In terms of outcomes, the definition of successful surgery is currently being debated. Synthetic mesh provides superior anatomical and subjective cure rates compared with native tissue repair. Success rates varied greatly depending on the nature of prolapse and surgical approach. Furthermore, recurrence rates for mesh-based surgery are significantly lower than that for native tissue repair. The main unique complication of mesh is exposure and was reported in a mean of 11.4% of patients, with 6.8% of patients requiring surgical partial excision of mesh. Mesh significantly improves anatomical outcomes with sacrocolpopexy and vaginal repair. Mesh does create the unique complication which can be reduced with training and proper patient selection. Further development of better materials is vital rather than reverting to tissue-based repair. Ultimately, the decision to use mesh should be based upon a patient's personal goals and preferences after an informed conversation with her physician.
Laparoscopy-like operative vaginoscopy: a new approach to manage mesh erosions.
Billone, Valentina; Amorim-Costa, Célia; Campos, Sara; Rabischong, Benoĭt; Bourdel, Nicolas; Canis, Michel; Botchorishvili, Revaz
2015-01-01
Mesh erosion through the vagina is the most common complication of synthetic mesh used for pelvic organ prolapse repair. However, conventional transvaginal mesh excision has many technical limitations. We aimed at creating and describing a new surgical technique for transvaginal removal of exposed mesh that would enable better exposition and access, thus facilitating optimal treatment. A step-by-step video showing the technique. A university tertiary care hospital. Five patients previously submitted to pelvic organ prolapse repair using synthetic mesh, presenting mesh erosion through the vagina. Mesh excision using a laparoscopy-like operative vaginoscopy in which standard laparoscopic instruments are used through a single-incision laparoscopic surgery port device placed in the vagina. In all cases, a very good exposure of the mesh was achieved, a minimal tissue traction was required, and the procedures were performed in a very ergonomic way. All the patients were discharged on the same day of the surgery and had a painless postoperative course. So far, there have been no cases of relapse. This seems to be a simple, cheap, and valuable minimally invasive technique with many advantages in comparison with the conventional approach. More cases and time are necessary to access its long-term efficacy. It may possibly be used for the management of other conditions. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.
Chughtai, Bilal; Mao, Jialin; Buck, Jessica; Kaplan, Steven; Sedrakyan, Art
2015-06-02
To assess the use of mesh in pelvic organ prolapse surgery, and compare short term outcomes between procedures using and not using mesh. All inclusive, population based cohort study. Statewide surgical care captured in the New York Statewide Planning and Research Cooperative System. Women who underwent prolapse repair procedures in New York state from 2008 to 2011. 90 day safety events and reinterventions within one year, after propensity score matching. Categorical, time to event, and subgroup analyses (<65 and ≥ 65 year age groups) were conducted. Of 27,991 patients in total, 7338 and 20, 653 underwent prolapse repair procedures with and without mesh, respectively. Mesh use increased by 44.7%, from 1461 procedures in 2008 to 2114 procedures in 2011. Most patients in the cohort were younger than 65 years (62.3% (n=17,424/27, 991)). However, more patients were aged 65 years and older in the mesh group than in the non-mesh group (44.3% (n=3249) v 35.4% (n=7318)). Complications after surgery were not common, irrespective of the use or non-use of mesh. After propensity score matching, patients who received the surgery with mesh had a higher chance of having a reintervention within one year (mesh 3.3% v no mesh 2.2%, hazard ratio 1.47 (95% confidence interval 1.21 to 1.79)) and were more likely to have urinary retention within 90 days (mesh 7.5% v no mesh 5.6%, risk ratio 1.33 (95% confidence interval 1.18 to 1.51)), compared with those who received surgery without mesh. In subgroup analyses based on age, mesh use was associated with an increased risk of reintervention within one year in patients under age 65 years, and increased risk of urinary retention in patients aged 65 years and over. Despite multiple warnings released by the US Food and Drug Administration since 2008, use of mesh in pelvic organ prolapse surgery continues to grow. In this statewide comprehensive study, mesh procedures were associated with an increased risk of reinterventions within one year and urinary retention after surgery. © Chughtai et al 2015.
Extended bounds limiter for high-order finite-volume schemes on unstructured meshes
NASA Astrophysics Data System (ADS)
Tsoutsanis, Panagiotis
2018-06-01
This paper explores the impact of the definition of the bounds of the limiter proposed by Michalak and Ollivier-Gooch in [56] (2009), for higher-order Monotone-Upstream Central Scheme for Conservation Laws (MUSCL) numerical schemes on unstructured meshes in the finite-volume (FV) framework. A new modification of the limiter is proposed where the bounds are redefined by utilising all the spatial information provided by all the elements in the reconstruction stencil. Numerical results obtained on smooth and discontinuous test problems of the Euler equations on unstructured meshes, highlight that the newly proposed extended bounds limiter exhibits superior performance in terms of accuracy and mesh sensitivity compared to the cell-based or vertex-based bounds implementations.
Jani, Saurin D; Argraves, Gary L; Barth, Jeremy L; Argraves, W Scott
2010-04-01
An important objective of DNA microarray-based gene expression experimentation is determining inter-relationships that exist between differentially expressed genes and biological processes, molecular functions, cellular components, signaling pathways, physiologic processes and diseases. Here we describe GeneMesh, a web-based program that facilitates analysis of DNA microarray gene expression data. GeneMesh relates genes in a query set to categories available in the Medical Subject Headings (MeSH) hierarchical index. The interface enables hypothesis driven relational analysis to a specific MeSH subcategory (e.g., Cardiovascular System, Genetic Processes, Immune System Diseases etc.) or unbiased relational analysis to broader MeSH categories (e.g., Anatomy, Biological Sciences, Disease etc.). Genes found associated with a given MeSH category are dynamically linked to facilitate tabular and graphical depiction of Entrez Gene information, Gene Ontology information, KEGG metabolic pathway diagrams and intermolecular interaction information. Expression intensity values of groups of genes that cluster in relation to a given MeSH category, gene ontology or pathway can be displayed as heat maps of Z score-normalized values. GeneMesh operates on gene expression data derived from a number of commercial microarray platforms including Affymetrix, Agilent and Illumina. GeneMesh is a versatile web-based tool for testing and developing new hypotheses through relating genes in a query set (e.g., differentially expressed genes from a DNA microarray experiment) to descriptors making up the hierarchical structure of the National Library of Medicine controlled vocabulary thesaurus, MeSH. The system further enhances the discovery process by providing links between sets of genes associated with a given MeSH category to a rich set of html linked tabular and graphic information including Entrez Gene summaries, gene ontologies, intermolecular interactions, overlays of genes onto KEGG pathway diagrams and heatmaps of expression intensity values. GeneMesh is freely available online at http://proteogenomics.musc.edu/genemesh/.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mille, M; Lee, C; Failla, G
Purpose: To use the Attila deterministic solver as a supplement to Monte Carlo for calculating out-of-field organ dose in support of epidemiological studies looking at the risks of second cancers. Supplemental dosimetry tools are needed to speed up dose calculations for studies involving large-scale patient cohorts. Methods: Attila is a multi-group discrete ordinates code which can solve the 3D photon-electron coupled linear Boltzmann radiation transport equation on a finite-element mesh. Dose is computed by multiplying the calculated particle flux in each mesh element by a medium-specific energy deposition cross-section. The out-of-field dosimetry capability of Attila is investigated by comparing averagemore » organ dose to that which is calculated by Monte Carlo simulation. The test scenario consists of a 6 MV external beam treatment of a female patient with a tumor in the left breast. The patient is simulated by a whole-body adult reference female computational phantom. Monte Carlo simulations were performed using MCNP6 and XVMC. Attila can export a tetrahedral mesh for MCNP6, allowing for a direct comparison between the two codes. The Attila and Monte Carlo methods were also compared in terms of calculation speed and complexity of simulation setup. A key perquisite for this work was the modeling of a Varian Clinac 2100 linear accelerator. Results: The solid mesh of the torso part of the adult female phantom for the Attila calculation was prepared using the CAD software SpaceClaim. Preliminary calculations suggest that Attila is a user-friendly software which shows great promise for our intended application. Computational performance is related to the number of tetrahedral elements included in the Attila calculation. Conclusion: Attila is being explored as a supplement to the conventional Monte Carlo radiation transport approach for performing retrospective patient dosimetry. The goal is for the dosimetry to be sufficiently accurate for use in retrospective epidemiological investigations.« less
NASA Astrophysics Data System (ADS)
Kim, Bu-Jong; Hwang, Young-Jin; Park, Jin-Seok
2017-04-01
Hybrid-type transparent conductive electrodes (TCEs) were fabricated by coating copper (Cu) meshes with carbon nanotube (CNT) via electrophoretic deposition, and with nickel (Ni) via electroplating. For the fabricated electrodes, the effects of the coating with CNT and Ni on their transmittance and reflectance in the visible-light range, electrical sheet resistance, and chromatic parameters (e.g., redness and yellowness) were characterized. Also, an oxidation stability test was performed by exposing the electrodes to air for 20 d at 85 °C and 85% temperature and humidity conditions, respectively. It was discovered that the CNT coating considerably reduced the reflectance of the Cu meshes, and that the Ni coating effectively protected the Cu meshes against oxidation. Furthermore, after the coating with CNT, both the redness and yellowness of the Cu mesh regardless of the Ni coating approached almost zero, indicating a natural color. The experiment results confirmed that the hybrid-type Cu meshes with combined Ni-CNT coating improved characteristics in terms of reflectance, sheet resistance, oxidation stability, and color, superior to those of the primitive Cu mesh, and also simultaneously satisfied most of the requirements for TCEs.
NASA Astrophysics Data System (ADS)
Grayver, Alexander V.
2015-07-01
This paper presents a distributed magnetotelluric inversion scheme based on adaptive finite-element method (FEM). The key novel aspect of the introduced algorithm is the use of automatic mesh refinement techniques for both forward and inverse modelling. These techniques alleviate tedious and subjective procedure of choosing a suitable model parametrization. To avoid overparametrization, meshes for forward and inverse problems were decoupled. For calculation of accurate electromagnetic (EM) responses, automatic mesh refinement algorithm based on a goal-oriented error estimator has been adopted. For further efficiency gain, EM fields for each frequency were calculated using independent meshes in order to account for substantially different spatial behaviour of the fields over a wide range of frequencies. An automatic approach for efficient initial mesh design in inverse problems based on linearized model resolution matrix was developed. To make this algorithm suitable for large-scale problems, it was proposed to use a low-rank approximation of the linearized model resolution matrix. In order to fill a gap between initial and true model complexities and resolve emerging 3-D structures better, an algorithm for adaptive inverse mesh refinement was derived. Within this algorithm, spatial variations of the imaged parameter are calculated and mesh is refined in the neighborhoods of points with the largest variations. A series of numerical tests were performed to demonstrate the utility of the presented algorithms. Adaptive mesh refinement based on the model resolution estimates provides an efficient tool to derive initial meshes which account for arbitrary survey layouts, data types, frequency content and measurement uncertainties. Furthermore, the algorithm is capable to deliver meshes suitable to resolve features on multiple scales while keeping number of unknowns low. However, such meshes exhibit dependency on an initial model guess. Additionally, it is demonstrated that the adaptive mesh refinement can be particularly efficient in resolving complex shapes. The implemented inversion scheme was able to resolve a hemisphere object with sufficient resolution starting from a coarse discretization and refining mesh adaptively in a fully automatic process. The code is able to harness the computational power of modern distributed platforms and is shown to work with models consisting of millions of degrees of freedom. Significant computational savings were achieved by using locally refined decoupled meshes.
Finite element meshing approached as a global minimization process
DOE Office of Scientific and Technical Information (OSTI.GOV)
WITKOWSKI,WALTER R.; JUNG,JOSEPH; DOHRMANN,CLARK R.
2000-03-01
The ability to generate a suitable finite element mesh in an automatic fashion is becoming the key to being able to automate the entire engineering analysis process. However, placing an all-hexahedron mesh in a general three-dimensional body continues to be an elusive goal. The approach investigated in this research is fundamentally different from any other that is known of by the authors. A physical analogy viewpoint is used to formulate the actual meshing problem which constructs a global mathematical description of the problem. The analogy used was that of minimizing the electrical potential of a system charged particles within amore » charged domain. The particles in the presented analogy represent duals to mesh elements (i.e., quads or hexes). Particle movement is governed by a mathematical functional which accounts for inter-particles repulsive, attractive and alignment forces. This functional is minimized to find the optimal location and orientation of each particle. After the particles are connected a mesh can be easily resolved. The mathematical description for this problem is as easy to formulate in three-dimensions as it is in two- or one-dimensions. The meshing algorithm was developed within CoMeT. It can solve the two-dimensional meshing problem for convex and concave geometries in a purely automated fashion. Investigation of the robustness of the technique has shown a success rate of approximately 99% for the two-dimensional geometries tested. Run times to mesh a 100 element complex geometry were typically in the 10 minute range. Efficiency of the technique is still an issue that needs to be addressed. Performance is an issue that is critical for most engineers generating meshes. It was not for this project. The primary focus of this work was to investigate and evaluate a meshing algorithm/philosophy with efficiency issues being secondary. The algorithm was also extended to mesh three-dimensional geometries. Unfortunately, only simple geometries were tested before this project ended. The primary complexity in the extension was in the connectivity problem formulation. Defining all of the interparticle interactions that occur in three-dimensions and expressing them in mathematical relationships is very difficult.« less
Huang, Yuansheng; Yang, Zhirong; Wang, Jing; Zhuo, Lin; Li, Zhixia; Zhan, Siyan
2016-05-06
To compare the performance of search strategies to retrieve systematic reviews of diagnostic test accuracy from The Cochrane Library. Databases of CDSR and DARE in the Cochrane Library were searched for systematic reviews of diagnostic test accuracy published between 2008 and 2012 through nine search strategies. Each strategy consists of one group or combination of groups of searching filters about diagnostic test accuracy. Four groups of diagnostic filters were used. The Strategy combing all the filters was used as the reference to determine the sensitivity, precision, and the sensitivity x precision product for another eight Strategies. The reference Strategy retrieved 8029 records, of which 832 were eligible. The strategy only composed of MeSH terms about "accuracy measures" achieved the highest values in both precision (69.71%) and product (52.45%) with a moderate sensitivity (75.24%). The combination of MeSH terms and free text words about "accuracy measures" contributed little to increasing the sensitivity. Strategies composed of filters about "diagnosis" had similar sensitivity but lower precision and product to those composed of filters about "accuracy measures". MeSH term "exp'diagnosis' " achieved the lowest precision (9.78%) and product (7.91%), while its hyponym retrieved only half the number of records at the expense of missing 53 target articles. The precision was negatively correlated with sensitivities among the nine strategies. Compared to the filters about "diagnosis", the filters about "accuracy measures" achieved similar sensitivities but higher precision. When combining both terms, sensitivity of the strategy was enhanced obviously. The combination of MeSH terms and free text words about the same concept seemed to be meaningless for enhancing sensitivity. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Pelvic organ prolapse (POP) surgery: the evidence for the repairs.
Gomelsky, Alex; Penson, David F; Dmochowski, Roger R
2011-06-01
What is known on the subject? and What does the study add? Substantial experience of the outcomes has been gathered regarding the acute and sub-acute experience with various types of corrective procedures for POP. These include long-term POP correction as well as more recent recognition of improvement in functional disorders associated with POP such as UI, colorectal dysfunction, and sexual dysfunction. Long-term follow-up is available for some of the older types of interventions and current multicentre trials are being accrued with longer term follow-up for new interventions including mesh-type repairs. The study adds a condensed and summarized version of the current literature regarding the various interventions for POP and also provides an overview of the current controversies and areas where knowledge is incomplete and in need of further elaboration for definitive answers regarding optimization of surgical care for POP. Our aim is to summarise the available data on the transvaginal placement of synthetic mesh for pelvic organ prolapse (POP) repair, with a focus on the outcomes and complications of commercial POP-repair kits. As the stability and durability of autologous tissues may be questionable, nonabsorbable, synthetic materials are an attractive alternative for providing additional support during POP surgery. These materials are not novel, and most have been used for many years in surgical applications, e.g. hernia repairs. While theoretically appealing, the implantation of synthetic mesh in the pelvis may be associated with inherent adverse consequences, such as erosion, extrusion, and infection. Additionally, the routine use of these materials may carry potential long-term complications, such as dyspareunia, chronic pelvic pain, and vaginal distortion. The success and failure of mesh-augmented POP repair is related not only to the synthetic material itself, but also to patient- and surgeon-related factors. Recent warnings by the USA Food and Drug Administration and other groups regarding adverse events further complicate the decision to use synthetic mesh. © 2011 THE AUTHORS; BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.
Tasneem, Asba; Aberle, Laura; Ananth, Hari; Chakraborty, Swati; Chiswell, Karen; McCourt, Brian J.; Pietrobon, Ricardo
2012-01-01
Background The ClinicalTrials.gov registry provides information regarding characteristics of past, current, and planned clinical studies to patients, clinicians, and researchers; in addition, registry data are available for bulk download. However, issues related to data structure, nomenclature, and changes in data collection over time present challenges to the aggregate analysis and interpretation of these data in general and to the analysis of trials according to clinical specialty in particular. Improving usability of these data could enhance the utility of ClinicalTrials.gov as a research resource. Methods/Principal Results The purpose of our project was twofold. First, we sought to extend the usability of ClinicalTrials.gov for research purposes by developing a database for aggregate analysis of ClinicalTrials.gov (AACT) that contains data from the 96,346 clinical trials registered as of September 27, 2010. Second, we developed and validated a methodology for annotating studies by clinical specialty, using a custom taxonomy employing Medical Subject Heading (MeSH) terms applied by an NLM algorithm, as well as MeSH terms and other disease condition terms provided by study sponsors. Clinical specialists reviewed and annotated MeSH and non-MeSH disease condition terms, and an algorithm was created to classify studies into clinical specialties based on both MeSH and non-MeSH annotations. False positives and false negatives were evaluated by comparing algorithmic classification with manual classification for three specialties. Conclusions/Significance The resulting AACT database features study design attributes parsed into discrete fields, integrated metadata, and an integrated MeSH thesaurus, and is available for download as Oracle extracts (.dmp file and text format). This publicly-accessible dataset will facilitate analysis of studies and permit detailed characterization and analysis of the U.S. clinical trials enterprise as a whole. In addition, the methodology we present for creating specialty datasets may facilitate other efforts to analyze studies by specialty groups. PMID:22438982
Tasneem, Asba; Aberle, Laura; Ananth, Hari; Chakraborty, Swati; Chiswell, Karen; McCourt, Brian J; Pietrobon, Ricardo
2012-01-01
The ClinicalTrials.gov registry provides information regarding characteristics of past, current, and planned clinical studies to patients, clinicians, and researchers; in addition, registry data are available for bulk download. However, issues related to data structure, nomenclature, and changes in data collection over time present challenges to the aggregate analysis and interpretation of these data in general and to the analysis of trials according to clinical specialty in particular. Improving usability of these data could enhance the utility of ClinicalTrials.gov as a research resource. The purpose of our project was twofold. First, we sought to extend the usability of ClinicalTrials.gov for research purposes by developing a database for aggregate analysis of ClinicalTrials.gov (AACT) that contains data from the 96,346 clinical trials registered as of September 27, 2010. Second, we developed and validated a methodology for annotating studies by clinical specialty, using a custom taxonomy employing Medical Subject Heading (MeSH) terms applied by an NLM algorithm, as well as MeSH terms and other disease condition terms provided by study sponsors. Clinical specialists reviewed and annotated MeSH and non-MeSH disease condition terms, and an algorithm was created to classify studies into clinical specialties based on both MeSH and non-MeSH annotations. False positives and false negatives were evaluated by comparing algorithmic classification with manual classification for three specialties. The resulting AACT database features study design attributes parsed into discrete fields, integrated metadata, and an integrated MeSH thesaurus, and is available for download as Oracle extracts (.dmp file and text format). This publicly-accessible dataset will facilitate analysis of studies and permit detailed characterization and analysis of the U.S. clinical trials enterprise as a whole. In addition, the methodology we present for creating specialty datasets may facilitate other efforts to analyze studies by specialty groups.
USDA-ARS?s Scientific Manuscript database
Such Biomedical vocabularies and ontologies aid in recapitulating biological knowledge. The annotation of gene products is mainly accelerated by Gene Ontology (GO) and more recently by Medical Subject Headings (MeSH). MeSH is the National Library of Medicine's controlled vocabulary and it is making ...
Haskins, Ivy N; Voeller, Guy R; Stoikes, Nathaniel F; Webb, David L; Chandler, Robert G; Phillips, Sharon; Poulose, Benjamin K; Rosen, Michael J
2017-05-01
The use of mesh during ventral hernia repair (VHR) is a well-accepted concept. However, the ideal location of mesh placement remains strongly debated. Although VHR with onlay mesh placement has historically been associated with a high rate of wound events, this surgical approach is technically less challenging than VHR with sublay mesh placement. The purpose of this study was to compare 30-day wound events after onlay mesh placement with adhesive fixation vs those after sublay mesh placement using the Americas Hernia Society Quality Collaborative database. All patients undergoing elective, open VHR with synthetic mesh placement from January 2013 through January 2016 were identified within the Americas Hernia Society Quality Collaborative. Only patients with clean wounds were included. Patients were divided into 2 groups: onlay mesh placement with the use of adhesive and sublay mesh placement. The association of mesh location with 30-day wound events was investigated using a matched analysis. A total of 1,854 patients met inclusion criteria; 1,761 (95.0%) underwent sublay mesh placement and 93 (5.0%) underwent onlay mesh placement with the use of adhesive. A 2:1 sublay to onlay matched analysis was performed based on factors previously shown to influence wound events after VHR. After matching, both groups had a lower mean Ventral Hernia Working Group grade and fewer associated comorbidities. There was no statistically significant difference between the sublay and onlay groups with respect to 30-day surgical site infections (2.9% vs 5.5%; p = 0.30), surgical site occurrences (15.2% vs 7.7%; p = 0.08), or surgical site occurrences requiring procedural intervention (8.2% vs 5.5%; p = 0.42). Ventral hernia repair with onlay mesh placement is a safe alternative to VHR with sublay mesh placement in low-risk patients. Additional studies are needed to determine the long-term mesh outcomes and recurrence rates in both of these groups. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Hong, Ling; Li, Huai-Fang; Sun, Jing; Zhu, Jian-Long; Ai, Gui-hai; Li, Li; Zhang, Bo; Chi, Feng-li; Tong, Xiao-Wen
2012-01-01
To explore the feasibility and effectiveness of a modified posterior vaginal mesh suspension method in treating female rectocele with intractable constipation. Descriptive study (Canadian Task Force classification II-3). The study was performed in the Study Center for Female Pelvic Dysfunction Disease, Department of Obstetrics and Gynecology, Tongji Hospital, Tongji University School of Medicine, Shanghai, China. The Study Center includes 15 physicians, most of whom have received advanced training in pelvic floor dysfunctional disease and can skillfully perform many types of operations in patients with such disease. Almost 1500 operations to treat pelvic floor dysfunctional disease are performed every year at the center. Thirty-six women with rectocele with intractable constipation. Posterior vaginal mesh suspension. All patients were followed up for 15 to 36 months. In 29 patients, the condition was cured completely; in 5 patients it had improved; and in 2 patients, the intervention had no effect. Insofar as recovery and improved results, the overall effectiveness rate was 94.4%. Posterior vaginal mesh suspension is an effective, harmless, and convenient method for treatment of female rectocele with intractable constipation. It has positive short-term curative effects, with few complications and sequelae. However, the long-term effects of posterior vaginal mesh suspension should be evaluated. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.
Caveney, Maxx; Haddad, Devin; Matthews, Catherine; Badlani, Gopal; Mirzazadeh, Majid
2017-11-01
Vaginal reconstructive surgery can be performed with or without mesh. We sought to determine comparative rates of perioperative complications of native tissue versus vaginal mesh repairs for pelvic organ prolapse. Using the National Surgical Quality Improvement Program (NSQIP) database, we concatenated surgical data from vaginal procedures for prolapse repair, including anterior and posterior colporrhaphy, paravaginal defect repair, enterocele repair, and vaginal colpopexy using Current Procedural Terminology (CPT) coding. We stratified this data by the modifier associated with mesh usage at the time of the procedure. We then compared 30-day perioperative outcomes, postoperative complications (bleeding, infection, etc), and readmission rates between women with and without mesh-based repairs. We identified 10 657 vaginal reconstructive procedures without mesh and 959 mesh-based repairs from 2009 through 2013. Patients undergoing mesh repair were more likely to experience at least one complication than native tissue repair (9.28% vs 6.15%, P < 0.001), with the overall complication rate also being higher in the mesh group (11.37% vs 9.39%, P = 0.03). Procedures with mesh had a higher rate of perioperative bleeding requiring transfusion than native tissue repair (2.3% vs 0.49%, P < 0.001), and organ surgical site infection (SSI) (0.52% vs 0.17%, P = 0.02). There were no significant differences in rates of readmission, superficial, or deep SSIs, pneumonia, urinary tract infection, sepsis, or renal failure. The use of vaginal mesh for pelvic organ prolapse repair appears to result in a higher rate of perioperative complications than native tissue repair. Patients undergoing these procedures should be counselled preoperatively concerning these risks. © 2017 Wiley Periodicals, Inc.
Long-term follow-up of treatment for synthetic mesh complications.
Hansen, Brooke L; Dunn, Guinn Ellen; Norton, Peggy; Hsu, Yvonne; Nygaard, Ingrid
2014-01-01
The objectives of this study are (1) to describe the presenting symptoms, findings, and treatment and (2) to describe the self-reported improvement and function at least 6 months after presentation in women presenting to 1 urogynecology division for complications associated with synthetic vaginal mesh. Women evaluated between 2006 and 2011 were identified by diagnostic codes. We abstracted information from the medical record and attempted to contact all women to complete a follow-up telephone survey questionnaire consisting of several validated instruments. A total of 111 women were evaluated for complications associated with synthetic vaginal mesh. The mean interval from index surgery was 2.4 years. Of these, 84% were referred from outside hospitals. Index surgeries included vaginal mesh kits/vaginally placed mesh (47%), midurethral mesh slings (37%), abdominally placed vaginal mesh (11%), and vaginal mesh kit with concomitantly placed mesh sling (5%). The most common complications were extrusion (65%), contraction (17%), and chronic pelvic pain (16%). A total of 98 women underwent some type of treatment (85 surgical) by urogynecologists, pelvic pain specialists, or physical therapists. Eighty-four (76%) provided follow-up information at mean interval since presentation of 2.3 years. At follow-up, the mean (SD) Pelvic Floor Distress Inventory score was 98 (67), the mean (SD) EQ-5D index score was 0.69 (0.23), and 22% reported vaginal discharge, 15% vaginal bleeding or spotting, and 45% sexual abstinence due to problems related to mesh. A total of 71% reported being overall better, whereas 29% were the same or worse. Two years after tertiary care level multidisciplinary treatment of vaginal mesh complications, many women still report symptoms that negatively impact their quality of life.
Fog water collection effectiveness: Mesh intercomparisons
Fernandez, Daniel; Torregrosa, Alicia; Weiss-Penzias, Peter; Zhang, Bong June; Sorensen, Deckard; Cohen, Robert; McKinley, Gareth; Kleingartner, Justin; Oliphant, Andrew; Bowman, Matthew
2018-01-01
To explore fog water harvesting potential in California, we conducted long-term measurements involving three types of mesh using standard fog collectors (SFC). Volumetric fog water measurements from SFCs and wind data were collected and recorded in 15-minute intervals over three summertime fog seasons (2014–2016) at four California sites. SFCs were deployed with: standard 1.00 m2 double-layer 35% shade coefficient Raschel; stainless steel mesh coated with the MIT-14 hydrophobic formulation; and FogHa-Tin, a German manufactured, 3-dimensional spacer fabric deployed in two orientations. Analysis of 3419 volumetric samples from all sites showed strong relationships between mesh efficiency and wind speed. Raschel mesh collected 160% more fog water than FogHa-Tin at wind speeds less than 1 m s–1 and 45% less for wind speeds greater than 5 m s–1. MIT-14 coated stainless-steel mesh collected more fog water than Raschel mesh at all wind speeds. At low wind speeds of < 1 m s–1 the coated stainless steel mesh collected 3% more and at wind speeds of 4–5 m s–1, it collected 41% more. FogHa-Tin collected 5% more fog water when the warp of the weave was oriented vertically, per manufacturer specification, than when the warp of the weave was oriented horizontally. Time series measurements of three distinct mesh across similar wind regimes revealed inconsistent lags in fog water collection and inconsistent performance. Since such differences occurred under similar wind-speed regimes, we conclude that other factors play important roles in mesh performance, including in-situ fog event and aerosol dynamics that affect droplet-size spectra and droplet-to-mesh surface interactions.
Biomechanical analyses of mesh fixation in TAPP and TEP hernia repair.
Schwab, R; Schumacher, O; Junge, K; Binnebösel, M; Klinge, U; Becker, H P; Schumpelick, V
2008-03-01
Reliable laparoscopic fixation of meshes prior to their fibrous incorporation is intended to minimize recurrences following transabdominal preperitoneal hernia repair (TAPP) and totally extraperitoneal repair (TEP) repair of inguinal hernias. However, suture-, tack- and staple-based fixation systems are associated with postoperative chronic inguinal pain. Initial fixation with fibrin sealant offers an atraumatic alternative, but there is little data demonstrating directly whether fibrin-based mesh adhesion provides adequate biomechanical stability for repair of inguinal hernia by TAPP and TEP. Using a newly developed, standardized simulation model for abdominal wall hernias, sublay repairs were performed with six different types of commercially available hernia mesh. The biomechanical stability achieved, and the protection afforded by the mesh-hernia overlap, were compared for three different techniques: nonfixation, point-by-point suture fixation, and fibrin sealant fixation. Mesh dislocation from the repaired hernia defect was consistently seen with nonfixation. This was reliably prevented with all six mesh types when fixed using either sutures or fibrin sealant. The highest stress resistance across the whole abdominal wall was found following superficial fixation with fibrin sealant across the mesh types. There was a highly statistically significant improvement in fixation stability with fibrin sealant versus fixation using eight single sutures (p = 0.008), as assessed by the range of achievable peak pressure stress up to 200 mmHg. To ensure long-term freedom from recurrence, intraoperative mesh-hernia overlap must be retained. This can be achieved with fibrin sealant up to the incorporation of the mesh - without trauma and with biomechanical stability.
NASA Astrophysics Data System (ADS)
Xin, Qin; Yao, Xiaolan; Engelstad, Paal E.
2010-09-01
Wireless Mesh Networking is an emerging communication paradigm to enable resilient, cost-efficient and reliable services for the future-generation wireless networks. We study here the minimum-latency communication primitive of gossiping (all-to-all communication) in multi-hop ad-hoc Wireless Mesh Networks (WMNs). Each mesh node in the WMN is initially given a message and the objective is to design a minimum-latency schedule such that each mesh node distributes its message to all other mesh nodes. Minimum-latency gossiping problem is well known to be NP-hard even for the scenario in which the topology of the WMN is known to all mesh nodes in advance. In this paper, we propose a new latency-efficient approximation scheme that can accomplish gossiping task in polynomial time units in any ad-hoc WMN under consideration of Large Interference Range (LIR), e.g., the interference range is much larger than the transmission range. To the best of our knowledge, it is first time to investigate such a scenario in ad-hoc WMNs under LIR, our algorithm allows the labels (e.g., identifiers) of the mesh nodes to be polynomially large in terms of the size of the WMN, which is the first time that the scenario of large labels has been considered in ad-hoc WMNs under LIR. Furthermore, our gossiping scheme can be considered as a framework which can be easily implied to the scenario under consideration of mobility-related issues since we assume that the mesh nodes have no knowledge on the network topology even for its neighboring mesh nodes.
NASA Astrophysics Data System (ADS)
Zhou, Feng; Chen, Guoxian; Huang, Yuefei; Yang, Jerry Zhijian; Feng, Hui
2013-04-01
A new geometrical conservative interpolation on unstructured meshes is developed for preserving still water equilibrium and positivity of water depth at each iteration of mesh movement, leading to an adaptive moving finite volume (AMFV) scheme for modeling flood inundation over dry and complex topography. Unlike traditional schemes involving position-fixed meshes, the iteration process of the AFMV scheme moves a fewer number of the meshes adaptively in response to flow variables calculated in prior solutions and then simulates their posterior values on the new meshes. At each time step of the simulation, the AMFV scheme consists of three parts: an adaptive mesh movement to shift the vertices position, a geometrical conservative interpolation to remap the flow variables by summing the total mass over old meshes to avoid the generation of spurious waves, and a partial differential equations(PDEs) discretization to update the flow variables for a new time step. Five different test cases are presented to verify the computational advantages of the proposed scheme over nonadaptive methods. The results reveal three attractive features: (i) the AMFV scheme could preserve still water equilibrium and positivity of water depth within both mesh movement and PDE discretization steps; (ii) it improved the shock-capturing capability for handling topographic source terms and wet-dry interfaces by moving triangular meshes to approximate the spatial distribution of time-variant flood processes; (iii) it was able to solve the shallow water equations with a relatively higher accuracy and spatial-resolution with a lower computational cost.
Porcine dermis implants in soft-tissue reconstruction: current status
Smart, Neil J; Bryan, Nicholas; Hunt, John A; Daniels, Ian R
2014-01-01
Soft-tissue reconstruction for a variety of surgical conditions, such as abdominal wall hernia or pelvic organ prolapse, remains a challenge. There are numerous meshes available that may be simply categorized as either synthetic or biologic. Within biologic meshes, porcine dermal meshes have come to dominate the market. This review examines the current evidence for their use and the limitations of knowledge. Although there is increasing evidence to support their safety, long-term follow-up studies that support their efficacy are lacking. Numerous clinical trials that remain ongoing may help elucidate their precise role in soft-tissue reconstruction. PMID:24648721
Identification of iPhone and iPad applications for obstetrics and gynecology providers.
Farag, Sara; Chyjek, Kathy; Chen, Katherine T
2014-11-01
To systematically identify the number of applications ("apps") compatible with the iPhone and the iPad that are potentially useful to obstetrician-gynecologists (ob-gyns). Obstetrics and gynecology MeSH terms were searched in the Apple iTunes Store. A master list of unique apps was created and the apps were divided into categories and subcategories. A total of 1,816 unique apps using 55 different obstetrics and gynecology MeSH terms were found. Of these unique apps, 242 apps (13.3%) were considered potentially useful to ob-gyns. The MeSH terms that yielded the highest number of potentially useful apps were "gynecology" (23%), "breast cancer" (17%), "obstetrics" (14%), and "pregnancy" (12%). Less than 15% of apps found were considered potentially useful to ob-gyns. Thus, the obstetrics and gynecology community is in need of an organized effort to identify, review, and determine the accuracy of apps that can potentially improve the performance of health care providers and lead to better patient outcomes. We propose the formation of a committee to guide in this important task.
Matrix multiplication on the Intel Touchstone Delta
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huss-Lederman, S.; Jacobson, E.M.; Tsao, A.
1993-12-31
Matrix multiplication is a key primitive in block matrix algorithms such as those found in LAPACK. We present results from our study of matrix multiplication algorithms on the Intel Touchstone Delta, a distributed memory message-passing architecture with a two-dimensional mesh topology. We obtain an implementation that uses communication primitives highly suited to the Delta and exploits the single node assembly-coded matrix multiplication. Our algorithm is completely general, able to deal with arbitrary mesh aspect ratios and matrix dimensions, and has achieved parallel efficiency of 86% with overall peak performance in excess of 8 Gflops on 256 nodes for an 8800more » {times} 8800 matrix. We describe our algorithm design and implementation, and present performance results that demonstrate scalability and robust behavior over varying mesh topologies.« less
Mapping Japanese medical terms to UMLS Metathesaurus.
Onogi, Yuzo; Ohe, Kazuhiko; Tanaka, Masaaki; Nozoe, Atsutake; Sasaki, Tetsuro; Sato, Megumi; Kikuchi, Yuko; Shinohara, Tsuneki; Suzuki, Hiromichi; Kaihara, Shigekoto; Seyama, Yousuke
2004-01-01
This paper introduces and reports the results for a project to map Japanese medical terms to the UMLS Metathesaurus. The "Thesaurus for Medical and Health related Terms version 5" published in 2003 by the Japan Medical Abstracts Society and UMLS version 2002AC provided by NLM were used in this study. The goal was to judge the validity of the correlation between the Japanese and English terms that belong to the same MeSH concept. Fifteen medicine, nursing, and library science professionals, excluding JAMAS, used a custom designed Web interface to perform this task. About 10% of the concepts were judged as invalid, and the reasoning behind these failures were analyzed. Experience from this project can be used to estimate the manpower required to revise the Japanese thesaurus after future revisions to UMLS or MeSH.
3D face analysis by using Mesh-LBP feature
NASA Astrophysics Data System (ADS)
Wang, Haoyu; Yang, Fumeng; Zhang, Yuming; Wu, Congzhong
2017-11-01
Objective: Face Recognition is one of the widely application of image processing. Corresponding two-dimensional limitations, such as the pose and illumination changes, to a certain extent restricted its accurate rate and further development. How to overcome the pose and illumination changes and the effects of self-occlusion is the research hotspot and difficulty, also attracting more and more domestic and foreign experts and scholars to study it. 3D face recognition fusing shape and texture descriptors has become a very promising research direction. Method: Our paper presents a 3D point cloud based on mesh local binary pattern grid (Mesh-LBP), then feature extraction for 3D face recognition by fusing shape and texture descriptors. 3D Mesh-LBP not only retains the integrity of the 3D geometry, is also reduces the need for recognition process of normalization steps, because the triangle Mesh-LBP descriptor is calculated on 3D grid. On the other hand, in view of multi-modal consistency in face recognition advantage, construction of LBP can fusing shape and texture information on Triangular Mesh. In this paper, some of the operators used to extract Mesh-LBP, Such as the normal vectors of the triangle each face and vertex, the gaussian curvature, the mean curvature, laplace operator and so on. Conclusion: First, Kinect devices obtain 3D point cloud face, after the pretreatment and normalization, then transform it into triangular grid, grid local binary pattern feature extraction from face key significant parts of face. For each local face, calculate its Mesh-LBP feature with Gaussian curvature, mean curvature laplace operator and so on. Experiments on the our research database, change the method is robust and high recognition accuracy.
Improvements to the Unstructured Mesh Generator MESH3D
NASA Technical Reports Server (NTRS)
Thomas, Scott D.; Baker, Timothy J.; Cliff, Susan E.
1999-01-01
The AIRPLANE process starts with an aircraft geometry stored in a CAD system. The surface is modeled with a mesh of triangles and then the flow solver produces pressures at surface points which may be integrated to find forces and moments. The biggest advantage is that the grid generation bottleneck of the CFD process is eliminated when an unstructured tetrahedral mesh is used. MESH3D is the key to turning around the first analysis of a CAD geometry in days instead of weeks. The flow solver part of AIRPLANE has proven to be robust and accurate over a decade of use at NASA. It has been extensively validated with experimental data and compares well with other Euler flow solvers. AIRPLANE has been applied to all the HSR geometries treated at Ames over the course of the HSR program in order to verify the accuracy of other flow solvers. The unstructured approach makes handling complete and complex geometries very simple because only the surface of the aircraft needs to be discretized, i.e. covered with triangles. The volume mesh is created automatically by MESH3D. AIRPLANE runs well on multiple platforms. Vectorization on the Cray Y-MP is reasonable for a code that uses indirect addressing. Massively parallel computers such as the IBM SP2, SGI Origin 2000, and the Cray T3E have been used with an MPI version of the flow solver and the code scales very well on these systems. AIRPLANE can run on a desktop computer as well. AIRPLANE has a future. The unstructured technologies developed as part of the HSR program are now targeting high Reynolds number viscous flow simulation. The pacing item in this effort is Navier-Stokes mesh generation.
Merali, N.; Almeida, R.A.R.; Hussain, A.
2015-01-01
Introduction We present a case on conservative management of salvaging the mesh in an immunocompromised morbidly obese patient, who developed a synergistic gangrene infection following a primary open mesh repair of an incisional hernia. Presentation of case Our patient presented with a surgical wound infection, comorbidities were Chronic Lymphoblastic Leukemia (CLL), Body Mass Index (BMI) of 50, hypertension and diet controlled type-2 diabetes. In surgery, wide necrotic wound debridement, early and repetitive wound drainages with the use of a large pore polypropylene mesh and a detailed surgical follow up was required. High dose intravenous broad-spectrum antibiotic treatment and Negative Pressure Wound Therapy (NPWT) was administrated in combination with adopting a multidisciplinary approach was key to our success. Discussion Stoppa Re et al. complied a series of 360 ventral hernia mesh repairs reporting an infection rate of 12% that were managed conservatively. However, our selective case is unique within current literature, being the first to illustrate mesh salvage in a morbid obese patient with CLL. Recent modifications in mesh morphology, such as lower density, wide pores, and lighter weight has led to considerable improvements regarding infection avoidance. Conclusion This case has demonstrated how a planned multidisciplinary action can produce prosperous results in a severely obese immunocompromised patient with an SSI, following an incisional hernia repair. PMID:26322822
Merali, N; Almeida, R A R; Hussain, A
2015-01-01
We present a case on conservative management of salvaging the mesh in an immunocompromised morbidly obese patient, who developed a synergistic gangrene infection following a primary open mesh repair of an incisional hernia. Our patient presented with a surgical wound infection, comorbidities were Chronic Lymphoblastic Leukemia (CLL), Body Mass Index (BMI) of 50, hypertension and diet controlled type-2 diabetes. In surgery, wide necrotic wound debridement, early and repetitive wound drainages with the use of a large pore polypropylene mesh and a detailed surgical follow up was required. High dose intravenous broad-spectrum antibiotic treatment and Negative Pressure Wound Therapy (NPWT) was administrated in combination with adopting a multidisciplinary approach was key to our success. Stoppa Re et al. complied a series of 360 ventral hernia mesh repairs reporting an infection rate of 12% that were managed conservatively. However, our selective case is unique within current literature, being the first to illustrate mesh salvage in a morbid obese patient with CLL. Recent modifications in mesh morphology, such as lower density, wide pores, and lighter weight has led to considerable improvements regarding infection avoidance. This case has demonstrated how a planned multidisciplinary action can produce prosperous results in a severely obese immunocompromised patient with an SSI, following an incisional hernia repair. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hewett, D.W.; Yu-Jiuan Chen
The authors describe how they hold onto orthogonal mesh discretization when dealing with curved boundaries. Special difference operators were constructed to approximate numerical zones split by the domain boundary; the operators are particularly simple for this rectangular mesh. The authors demonstrated that this simple numerical approach, termed Dynamic Alternating Direction Implicit, turned out to be considerably more efficient than more complex grid-adaptive algorithms that were tried previously.
Anisotropic mesh adaptation for marine ice-sheet modelling
NASA Astrophysics Data System (ADS)
Gillet-Chaulet, Fabien; Tavard, Laure; Merino, Nacho; Peyaud, Vincent; Brondex, Julien; Durand, Gael; Gagliardini, Olivier
2017-04-01
Improving forecasts of ice-sheets contribution to sea-level rise requires, amongst others, to correctly model the dynamics of the grounding line (GL), i.e. the line where the ice detaches from its underlying bed and goes afloat on the ocean. Many numerical studies, including the intercomparison exercises MISMIP and MISMIP3D, have shown that grid refinement in the GL vicinity is a key component to obtain reliable results. Improving model accuracy while maintaining the computational cost affordable has then been an important target for the development of marine icesheet models. Adaptive mesh refinement (AMR) is a method where the accuracy of the solution is controlled by spatially adapting the mesh size. It has become popular in models using the finite element method as they naturally deal with unstructured meshes, but block-structured AMR has also been successfully applied to model GL dynamics. The main difficulty with AMR is to find efficient and reliable estimators of the numerical error to control the mesh size. Here, we use the estimator proposed by Frey and Alauzet (2015). Based on the interpolation error, it has been found effective in practice to control the numerical error, and has some flexibility, such as its ability to combine metrics for different variables, that makes it attractive. Routines to compute the anisotropic metric defining the mesh size have been implemented in the finite element ice flow model Elmer/Ice (Gagliardini et al., 2013). The mesh adaptation is performed using the freely available library MMG (Dapogny et al., 2014) called from Elmer/Ice. Using a setup based on the inter-comparison exercise MISMIP+ (Asay-Davis et al., 2016), we study the accuracy of the solution when the mesh is adapted using various variables (ice thickness, velocity, basal drag, …). We show that combining these variables allows to reduce the number of mesh nodes by more than one order of magnitude, for the same numerical accuracy, when compared to uniform mesh refinement. For transient solutions where the GL is moving, we have implemented an algorithm where the computation is reiterated allowing to anticipate the GL displacement and to adapt the mesh to the transient solution. We discuss the performance and robustness of this algorithm.
Köhler, Gernot; Fischer, Ines; Kaltenböck, Richard; Schrittwieser, Rudolf
2018-04-05
Patients with umbilical or epigastric hernias benefit from mesh- based repairs, and even more so if a concomitant rectus diastasis (RD) is present. The ideal technique is, however, still under debate. In this study we introduce the minimal invasive linea alba reconstruction (MILAR) with the supraaponeurotic placement of a fully absorbable synthetic mesh. Midline reconstruction with anterior rectus sheath repair and mesh augmentation by an open approach is a well-known surgical technique for ventral hernia repair. Between December 1, 2016, and November 30, 2017, 20 patients with symptomatic umbilical and/or epigastric hernias, and coexisting RD underwent a minimally invasive complete reconstruction of the midline through a small access route. The inner part of both incised and medialized anterior rectus sheaths was replaced by a fully absorbable synthetic mesh placed in a supraaponeurotic position. Patients were hospitalized for an average of 4 days and the mean operating time was 79 minutes. The mean hernia defect size was 1.5 cm in diameter and the mean mesh size was recorded as 15.8 cm in length and 5.2 cm in width. Two patients sustained surgical postoperative complications in terms of symptomatic seroma occurrences with successful interventional treatment.The early results (mean follow-up period of 5 months) showed no recurrences and only 1 patient reported occasional pain following exertion without rest. MILAR is a modification of the recently published endoscopic linea alba reconstruction restoring the normal anatomy of the abdominal wall. A new linea alba is formed with augmentation of autologous tissue consisting of the plicated anterior rectus sheaths. Supraaponeurotic placement of a fully absorbable synthetic mesh eliminates potential long-term mesh-associated complications. Regarding MILAR, there is no need for endoscopic equipment due to the uniquely designed flexible lighted retractors, meaning one assistant less is required.
Darmoni, Stéfan J; Soualmia, Lina F; Letord, Catherine; Jaulent, Marie-Christine; Griffon, Nicolas; Thirion, Benoît; Névéol, Aurélie
2012-07-01
As more scientific work is published, it is important to improve access to the biomedical literature. Since 2000, when Medical Subject Headings (MeSH) Concepts were introduced, the MeSH Thesaurus has been concept based. Nevertheless, information retrieval is still performed at the MeSH Descriptor or Supplementary Concept level. The study assesses the benefit of using MeSH Concepts for indexing and information retrieval. Three sets of queries were built for thirty-two rare diseases and twenty-two chronic diseases: (1) using PubMed Automatic Term Mapping (ATM), (2) using Catalog and Index of French-language Health Internet (CISMeF) ATM, and (3) extrapolating the MEDLINE citations that should be indexed with a MeSH Concept. Type 3 queries retrieve significantly fewer results than type 1 or type 2 queries (about 18,000 citations versus 200,000 for rare diseases; about 300,000 citations versus 2,000,000 for chronic diseases). CISMeF ATM also provides better precision than PubMed ATM for both disease categories. Using MeSH Concept indexing instead of ATM is theoretically possible to improve retrieval performance with the current indexing policy. However, using MeSH Concept information retrieval and indexing rules would be a fundamentally better approach. These modifications have already been implemented in the CISMeF search engine.
Large area nanoscale metal meshes for use as transparent conductive layers.
Jin, Yuanhao; Li, Qunqing; Chen, Mo; Li, Guanhong; Zhao, Yudan; Xiao, Xiaoyang; Wang, Jiaping; Jiang, Kaili; Fan, Shoushan
2015-10-21
We report on the experimental realization of using super-aligned carbon nanotubes (SACNTs) as etching masks for the fabrication of large area nanoscale metal meshes. This method can easily be extended to different metals on both rigid and flexible substrates. The as-fabricated metal meshes, including the ones made of gold, copper, and aluminum, are suitable for use as transparent conductive layers (TCLs). The metal meshes, which are similar to the SACNT networks in their dimensional features of tens of nanometers, exhibit compatible performance in terms of optical transmittance and sheet resistance. Moreover, because the metal meshes are fabricated as an integrated material, there is no junction resistance between the interconnected metal nanostructures, which markedly lowers their sheet resistance at high temperatures. The fabrication of such an effective etching mask involves a simple drawing process of the SACNT networks prepared and a common deposition process. This approach should be easy to extend to various research fields and has broad prospects in commercial applications.
Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
Singh, Tejinder P.; Dunnican, Ward J.; Binetti, Brian R.
2012-01-01
Background: Repairing large hiatal hernias using mesh has been shown to reduce recurrence. Drawbacks to mesh include added time to place and secure the prosthesis as well as complications such as esophageal erosion. We used a laparoscopic technique for repair of hiatal hernias (HH) >5cm, incorporating primary crural repair with onlay fixation of a synthetic polyglycolicacid:trimethylene carbonate (PGA:TMC) absorbable tissue reinforcement. The purpose of this report is to present short-term follow-up data. Methods: Patients with hiatal hernia types I-III and defects >5cm were included. Primary closure of the hernia defect was performed using interrupted nonpledgeted sutures, followed by PGA:TMC mesh onlay fixed with absorbable tacks. A fundoplication was then performed. Evaluation of patients was carried out at routine follow-up visits. Outcomes measured were symptoms of gastroesophageal reflux disease (GERD), or other symptoms suspicious for recurrence. Patients exhibiting these complaints underwent further evaluation including radiographic imaging and endoscopy. Results: Follow-up data were analyzed on 11 patients. Two patients were male; 9 were female. The mean age was 60 years. The mean length of follow-up was 13 months. There were no complications related to the mesh. One patient suffered from respiratory failure, one from gas bloat syndrome, and another had a superficial port-site infection. One patient developed a recurrent hiatal hernia. Conclusions: In this small series, laparoscopic repair of hiatal hernias >5cm with onlay fixation of PGA:TMC tissue reinforcement has short-term outcomes with a reasonably low recurrence rate. However, due to the preliminary and nonrandomized nature of the data, no strong comparison can be made with other types of mesh repairs. Additional data collection is warranted. PMID:22906331
Jacob, Dietmar A; Schug-Pass, Christine; Sommerer, Florian; Tannapfel, Andrea; Lippert, Hans; Köckerling, Ferdinand
2012-02-01
The use of a mesh with good biocompatibility properties is of decisive importance for the avoidance of recurrences and chronic pain in endoscopic hernia repair surgery. As we know from numerous experiments and clinical experience, large-pore, lightweight polypropylene meshes possess the best biocompatibility. However, large-pore meshes of different polymers may be used as well and might be an alternative solution. Utilizing a totally extraperitoneal technique in an established animal model, 20 domestic pigs were implanted with either a lightweight large-pore polypropylene (PP) mesh (Optilene® LP) or a medium-weight large-pore knitted polytetrafluorethylene (PTFE) mesh (GORE® INFINIT® mesh). After 94 days, the pigs were sacrificed and postmortem diagnostic laparoscopy was performed, followed by explantation of the specimens for macroscopic, histological and immunohistochemical evaluation. The mean mesh shrinkage rate was 14.2% for Optilene® LP vs. 24.7% for INFINIT® mesh (p = 0.017). The partial volume of the inflammatory cells was 11.2% for Optilene® LP vs. 13.9% for INFINIT (n.s.). CD68 was significantly higher for INFINIT (11.8% vs. 5.6%, p = 0.007). The markers of cell turnover, namely Ki67 and the apoptotic index, were comparable at 6.4% vs. 12.4% (n.s.) and 1.6% vs. 2.0% (n.s.). In the extracellular matrix, TGF-β was 35.4% for Optilene® LP and 31.0% for INFINIT® (n.s.). Collagen I (pos/300 μm) deposits were 117.8 and 114.9, respectively. In our experimental examinations, Optilene® LP and INFINIT® showed a comparable biocompatibility in terms of chronic inflammatory reaction; however, the shrinkage rate was significantly higher for INFINIT® after 3 months. The higher shrinkage rate of INFINIT® should be taken into account when choosing the mesh size for an adequate hernia overlap.
Pain and convalescence following laparoscopic ventral hernia repair.
Eriksen, Jens Ravn
2011-12-01
Severe pain is usual after laparoscopic ventral hernia repair (LVHR). Mesh fixation with titanium tacks may play a key role in the development of acute and chronic pain and alternative fixation methods should therefore be investigated. This PhD thesis was based on three studies and aimed too: 1) assess the intensity and impact of postoperative pain by detailed patient-reported description of pain and convalescence after LVHR (Study I), 2) evaluate the feasibility of fibrin sealant (FS) for mesh fixation in an experimental pig model (Study II), and 3) investigate FS vs. tacks for mesh fixation in LVHR in a randomised, double-blinded, clinical controlled study with acute postoperative pain as the primary outcome (Study III). In Study I - a prospective descriptive study - 35 patients were prospectively included and underwent LVHR. Scores of pain, quality of life, convalescence, fatigue, and general well-being were obtained from each patient. Follow-up was six months. Average pain from postoperative day (POD) 0-2 and POD 0-6 measured on a 0-100 mm visual analogue scale (VAS) was 61 and 48, respectively. Pain scores reached preoperative values at POD 30. The incidence of severe chronic pain was 7%. No parameter predicted postoperative pain significantly. Significant correlations were found between pain, and general well-being (rS= -0.8, p < 0.001), satisfaction (rS= -0.67, p < quality of life score (rS= -0.63, p < 0.001) six months postoperatively. Patients resumed normal daily activity at POD 14. In Study II - a randomised experimental study in pigs - nine pigs were operated laparoscopically with insertion of two different meshes fixed with either FS or tacks. All pigs were euthanized on POD 30. The primary outcome parameter was strength of ingrowth between the mesh and the anterior abdominal wall. A mechanical peel test was performed for each tissue sample. The secondary outcome parameters were grade and strength of adhesions to the mesh, shrinkage and displacement/folding of the mesh and histological parameters. All nine pigs survived without complications until sacrifice. No meshes were displaced from their initial position at autopsy, but in two cases mesh folding was observed. No significant difference in strength of ingrowth was found between different fixation methods or mesh types. Furthermore, no significant difference was found in grade or strength of adhesions or any histological parameters. In Study III - a randomised, controlled, double-blinded, multicenter trial - 40 patients with umbilical hernia defects between 1.5-5 cm, were randomly assigned to receive FS or titanium tacks for mesh fixation in LVHR. Patients, care givers and those assessing the outcomes were blinded to group assignment. The primary outcome was average pain from POD 0-2 (VAS score). Secondary outcome parameters were fatigue, general well-being and time to resume normal daily activity. Follow-up was one month for all. Patients in the FS group reported significantly less pain at POD 0-2 (median VAS 38 (range 6-98) vs. 60 (18-96), p = 0.01). Absolute VAS score difference between groups was 20 mm (95% CI 4-35 mm) at activity, and 19 mm (95% CI 3-34 mm) at rest. Patients in the FS group reported significantly less discomfort from POD 0-2 and POD 0-10, compared with the tack group. No significant difference was found in fatigue score between groups. No significant difference in hospital stay, hernia diameter, or morphine consumption in the post anesthesia care unit was found between groups. Patients in the FS group resumed normal daily activity at POD 7 (1-66) versus POD 18 (1-95) in the tack group (p = 0.03). No recurrences were observed. No adverse events or side effects were observed. No significant differences in predefined complications were found between groups. In conclusion, pain is a significant clinical problem after LVHR with impact on general well-being, quality of life and patient satisfaction. This issue must have first priority in future ventral hernia repair research. It is now documented, that the simple application of fibrin glue instead of titanium tacks for mesh fixation in LVHR of defects < 5 cm significantly reduced acute pain, discomfort and the period of convalescence. Long-term follow-up will show the value of FS fixation in terms of chronic pain and recurrence. As FS potentially may solve many of the outcome problems associated with LVHR, future studies should include larger hernia defects including large incisional hernias, as the operative technique may be different.
Adapting to life: ocean biogeochemical modelling and adaptive remeshing
NASA Astrophysics Data System (ADS)
Hill, J.; Popova, E. E.; Ham, D. A.; Piggott, M. D.; Srokosz, M.
2014-05-01
An outstanding problem in biogeochemical modelling of the ocean is that many of the key processes occur intermittently at small scales, such as the sub-mesoscale, that are not well represented in global ocean models. This is partly due to their failure to resolve sub-mesoscale phenomena, which play a significant role in vertical nutrient supply. Simply increasing the resolution of the models may be an inefficient computational solution to this problem. An approach based on recent advances in adaptive mesh computational techniques may offer an alternative. Here the first steps in such an approach are described, using the example of a simple vertical column (quasi-1-D) ocean biogeochemical model. We present a novel method of simulating ocean biogeochemical behaviour on a vertically adaptive computational mesh, where the mesh changes in response to the biogeochemical and physical state of the system throughout the simulation. We show that the model reproduces the general physical and biological behaviour at three ocean stations (India, Papa and Bermuda) as compared to a high-resolution fixed mesh simulation and to observations. The use of an adaptive mesh does not increase the computational error, but reduces the number of mesh elements by a factor of 2-3. Unlike previous work the adaptivity metric used is flexible and we show that capturing the physical behaviour of the model is paramount to achieving a reasonable solution. Adding biological quantities to the adaptivity metric further refines the solution. We then show the potential of this method in two case studies where we change the adaptivity metric used to determine the varying mesh sizes in order to capture the dynamics of chlorophyll at Bermuda and sinking detritus at Papa. We therefore demonstrate that adaptive meshes may provide a suitable numerical technique for simulating seasonal or transient biogeochemical behaviour at high vertical resolution whilst minimising the number of elements in the mesh. More work is required to move this to fully 3-D simulations.
Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy
2013-11-01
The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.
Bona, Stefano; Rosati, Riccardo; Opocher, Enrico; Fiore, Barbara; Montorsi, Marco
2018-03-01
Mesh repair has significantly reduced recurrence rate after groin hernia surgery. Recently, attention has shifted to issues such as chronic pain and discomfort, leading to development of lightweight and partially re-absorbable meshes. The aim of the study was to evaluate the effect of lightweight mesh vs heavyweight mesh on post-operative pain, discomfort and quality of life in short and medium term after inguinal hernia surgery. Eight hundred and eight patients with primary inguinal hernia were allocated to anterior repair (Lichtenstein technique) using a lightweight mesh (Ultrapro ® ) or a heavyweight mesh (Prolene ® ). Primary outcomes were incidence of chronic pain and discomfort at 6-month follow-up. Secondary endpoints were quality of life (QoL), pain and complication at 1 week, 1 and 6 months. At 6 months, 25% of patients reported pain of some intensity; severe pain was reported by 1% of patients in both groups. A statistically significant difference in favour of lightweight mesh was found at multivariable analysis for pain (1 week and 6 months after surgery: p = 0.02 and p = 0.04, respectively) and QoL at 1 month and 6 months (p = 0.05 and p = 0.02, respectively). There was no difference in complication rate and no hernia recurrences were detected. The use of lightweight mesh in anterior Lichtenstein inguinal hernia repair significantly reduced the incidence of pain and favourably affected the perceived quality of life at 6 months after surgery compared to heavyweight mesh.
Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse.
Takazawa, Naoko; Fujisaki, Akiko; Yoshimura, Yasukuni; Tsujimura, Akira; Horie, Shigeo
2018-03-01
This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP). This retrospective cohort study involved 91 women who underwent surgical management of POP with originally designed small mesh between July 2014 and August 2015. This mesh is 56% smaller than the mesh widely used in Japan, and it has only two arms delivered into each right and left sacrospinous ligament. The main study outcome was the anatomic cure rate defined as recurrence of POP quantification (POP-Q) stage II or more. We also assessed changes in the overactive bladder symptom score (OABSS) and prolapse quality of life questionnaire (P-QOL) and evaluated adverse events. Finally, we compared patient backgrounds between the patients with and without recurrence. Prolapse recurred in 10 of 91 patients (11.0%), and all patients with recurrence were diagnosed as POP-Q stage II. As adverse events, only mesh erosion occurred in two (2.2%) and pelvic pain in one (1.1%) of the 91 patients. The OABSS and P-QOL were significantly improved by the operation. When we compared patient backgrounds between the patients with and without recurrence, body mass index was the only factor influencing affecting recurrence. Transvaginal minimal mesh repair resulted in successful outcomes with low mesh-related complications and anatomic recurrence at one year. Furthermore, significant improvement in QOL was offered by this procedure. Our minimal mesh technique should be considered as one treatment option for the management of POP.
Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse
Takazawa, Naoko; Fujisaki, Akiko; Yoshimura, Yasukuni; Tsujimura, Akira
2018-01-01
Purpose This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP). Materials and Methods This retrospective cohort study involved 91 women who underwent surgical management of POP with originally designed small mesh between July 2014 and August 2015. This mesh is 56% smaller than the mesh widely used in Japan, and it has only two arms delivered into each right and left sacrospinous ligament. The main study outcome was the anatomic cure rate defined as recurrence of POP quantification (POP-Q) stage II or more. We also assessed changes in the overactive bladder symptom score (OABSS) and prolapse quality of life questionnaire (P-QOL) and evaluated adverse events. Finally, we compared patient backgrounds between the patients with and without recurrence. Results Prolapse recurred in 10 of 91 patients (11.0%), and all patients with recurrence were diagnosed as POP-Q stage II. As adverse events, only mesh erosion occurred in two (2.2%) and pelvic pain in one (1.1%) of the 91 patients. The OABSS and P-QOL were significantly improved by the operation. When we compared patient backgrounds between the patients with and without recurrence, body mass index was the only factor influencing affecting recurrence. Conclusions Transvaginal minimal mesh repair resulted in successful outcomes with low mesh-related complications and anatomic recurrence at one year. Furthermore, significant improvement in QOL was offered by this procedure. Our minimal mesh technique should be considered as one treatment option for the management of POP. PMID:29520390
Le Teuff, Isabelle; Huberlant, Stephanie; Carteron, Patrick; Letouzey, Vincent; de Tayrac, Renaud
2017-01-01
Objectives Synthetic mesh surgery for both abdominal and urogenital hernia repair is often unsatisfactory in the long-term due to postoperative complications. We hypothesized that a semi-degradable mesh hybrid may provide more appropriate biocompatibility with comparable mechanical properties. The aim was to compare its in vivo biocompatibility with a commercial polypropylene (PP) mesh. Methods 72 rats were randomly allocated to either our new composite mesh (monofilament PP mesh knitted with polylactic-acid-fibers (PLA)) or to a commercially available PP mesh that was used as a control. 15, 90, and 180 days after implantation into the rat abdomen mesh tissue complexes were analysed for erosion, contraction, foreign body reaction, tissue integration and biomechanical properties. Results No differences were seen in regard to clinical parameters including erosion, contraction or infection rates between the two groups. Biomechanical properties including breaking load, stiffness and deformation did not show any significant differences between the different materials at any timepoint. Macrophage staining did not reveal any significant differences between the two groups or between timepoints either. In regard to collagen I there was significantly less collagen I in the PP group compared to the PP/ PLA group at day 180. Collagen III did not show any significant differences at any timepoint between the two groups. Conclusion A PP/PLA hybrid mesh, leaving a low amount of PP after PLA degradation seems to have comparable biomechanical properties like PP at 180 days due to enhanced collagen production without significant differences in erosion, contraction, herniation or infection rates. PMID:28598983
Moving Particles Through a Finite Element Mesh
Peskin, Adele P.; Hardin, Gary R.
1998-01-01
We present a new numerical technique for modeling the flow around multiple objects moving in a fluid. The method tracks the dynamic interaction between each particle and the fluid. The movements of the fluid and the object are directly coupled. A background mesh is designed to fit the geometry of the overall domain. The mesh is designed independently of the presence of the particles except in terms of how fine it must be to track particles of a given size. Each particle is represented by a geometric figure that describes its boundary. This figure overlies the mesh. Nodes are added to the mesh where the particle boundaries intersect the background mesh, increasing the number of nodes contained in each element whose boundary is intersected. These additional nodes are then used to describe and track the particle in the numerical scheme. Appropriate element shape functions are defined to approximate the solution on the elements with extra nodes. The particles are moved through the mesh by moving only the overlying nodes defining the particles. The regular finite element grid remains unchanged. In this method, the mesh does not distort as the particles move. Instead, only the placement of particle-defining nodes changes as the particles move. Element shape functions are updated as the nodes move through the elements. This method is especially suited for models of moderate numbers of moderate-size particles, where the details of the fluid-particle coupling are important. Both the complications of creating finite element meshes around appreciable numbers of particles, and extensive remeshing upon movement of the particles are simplified in this method. PMID:28009377
Nune, K C; Misra, R D K; Li, S J; Hao, Y L; Zhang, W
2016-10-01
The objective of the study is to fundamentally elucidate the biological response of 3D printed mesh structures subjected to plasma electrolytic oxidation process through the study of osteoblast functions. The cellular activity of plasma electrolytic-oxidized mesh structure was explored in terms of cell-to-cell communication involving proliferation, synthesis of extracellular and intracellular proteins, and mineralization. Upon plasma electrolytic oxidation of the mesh structure, a thin layer of bioactive titania with pore size 1-3 µm was nucleated on the surface. The combination of microporous bioactive titania and interconnected porous architecture provided the desired pathway for supply of nutrients and oxygen to cells and tissue and a favorable osteogenic microenvironment for tissue on-growth and in-growth, in relation to the unmodified mesh structure. The formation of a confluent layer as envisaged via electron microscopy and quantitative assessment of the expression level of proteins (actin, vinculin, and fibronectin) point toward the determining role of surface-modified mesh structure in modulating osteoblasts functions. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2488-2501, 2016. © 2016 Wiley Periodicals, Inc.
Mesh quality oriented 3D geometric vascular modeling based on parallel transport frame.
Guo, Jixiang; Li, Shun; Chui, Yim Pan; Qin, Jing; Heng, Pheng Ann
2013-08-01
While a number of methods have been proposed to reconstruct geometrically and topologically accurate 3D vascular models from medical images, little attention has been paid to constantly maintain high mesh quality of these models during the reconstruction procedure, which is essential for many subsequent applications such as simulation-based surgical training and planning. We propose a set of methods to bridge this gap based on parallel transport frame. An improved bifurcation modeling method and two novel trifurcation modeling methods are developed based on 3D Bézier curve segments in order to ensure the continuous surface transition at furcations. In addition, a frame blending scheme is implemented to solve the twisting problem caused by frame mismatch of two successive furcations. A curvature based adaptive sampling scheme combined with a mesh quality guided frame tilting algorithm is developed to construct an evenly distributed, non-concave and self-intersection free surface mesh for vessels with distinct radius and high curvature. Extensive experiments demonstrate that our methodology can generate vascular models with better mesh quality than previous methods in terms of surface mesh quality criteria. Copyright © 2013 Elsevier Ltd. All rights reserved.
Unstructured Adaptive Meshes: Bad for Your Memory?
NASA Technical Reports Server (NTRS)
Biswas, Rupak; Feng, Hui-Yu; VanderWijngaart, Rob
2003-01-01
This viewgraph presentation explores the need for a NASA Advanced Supercomputing (NAS) parallel benchmark for problems with irregular dynamical memory access. This benchmark is important and necessary because: 1) Problems with localized error source benefit from adaptive nonuniform meshes; 2) Certain machines perform poorly on such problems; 3) Parallel implementation may provide further performance improvement but is difficult. Some examples of problems which use irregular dynamical memory access include: 1) Heat transfer problem; 2) Heat source term; 3) Spectral element method; 4) Base functions; 5) Elemental discrete equations; 6) Global discrete equations. Nonconforming Mesh and Mortar Element Method are covered in greater detail in this presentation.
NASA Technical Reports Server (NTRS)
Jentink, Thomas Neil; Usab, William J., Jr.
1990-01-01
An explicit, Multigrid algorithm was written to solve the Euler and Navier-Stokes equations with special consideration given to the coarse mesh boundary conditions. These are formulated in a manner consistent with the interior solution, utilizing forcing terms to prevent coarse-mesh truncation error from affecting the fine-mesh solution. A 4-Stage Hybrid Runge-Kutta Scheme is used to advance the solution in time, and Multigrid convergence is further enhanced by using local time-stepping and implicit residual smoothing. Details of the algorithm are presented along with a description of Jameson's standard Multigrid method and a new approach to formulating the Multigrid equations.
A bottom-up approach to MEDLINE indexing recommendations.
Jimeno-Yepes, Antonio; Wilkowski, Bartłomiej; Mork, James G; Van Lenten, Elizabeth; Fushman, Dina Demner; Aronson, Alan R
2011-01-01
MEDLINE indexing performed by the US National Library of Medicine staff describes the essence of a biomedical publication in about 14 Medical Subject Headings (MeSH). Since 2002, this task is assisted by the Medical Text Indexer (MTI) program. We present a bottom-up approach to MEDLINE indexing in which the abstract is searched for indicators for a specific MeSH recommendation in a two-step process. Supervised machine learning combined with triage rules improves sensitivity of recommendations while keeping the number of recommended terms relatively small. Improvement in recommendations observed in this work warrants further exploration of this approach to MTI recommendations on a larger set of MeSH headings.
Tang, Hua; Xu, Zhifei; Qin, Xiong; Wu, Bin; Wu, Lihui; Zhao, XueWei; Li, Yulin
2009-07-01
Extensive chest wall defect reconstruction remains a challenging problem for surgeons. In the past several years, little progress has been made in this area. In this study, a biodegradable polydioxanone (PDO) mesh and demineralized bone matrix (DBM) seeded with osteogenically induced bone marrow stromal cells (BMSCs) were used to reconstruct a 6 cm x 5.5 cm chest wall defect. Four experimental groups were evaluated (n=6 per group): polydioxanone (PDO) mesh/DBMs/BMSCs group, polydioxanone (PDO) mesh/DBMs group, polydioxanone (PDO) mesh group, and a blank group (no materials) in a canine model. All the animals survived except those in the blank group. In all groups receiving biomaterial implants, the polydioxanone (PDO) mesh completely degraded at 24 weeks and was replaced by fibrous tissue with thickness close to that of the normal intercostal tissue (P>0.05). In the polydioxanone (PDO) mesh/DBMs/BMSCs group, new bone formation and bone-union were observed by radiographic and histological examination. More importantly, the reconstructed rib could maintain its original radian and achieve satisfactory biomechanics close to normal ribs in terms of bending stress (P>0.05). However, in the other two groups, fibrous tissue was observed in the defect and junctions, and the reconstructed ribs were easily distorted under an outer force. Based on these results, a surgical approach utilizing biodegradable polydioxanone (PDO) mesh in combination with DBMs and BMSCs could repair the chest wall defect not only in function but also in structure.
Colorectal cancer in Malaysia: Its burden and implications for a multiethnic country.
Veettil, Sajesh K; Lim, Kean Ghee; Chaiyakunapruk, Nathorn; Ching, Siew Mooi; Abu Hassan, Muhammad Radzi
2017-11-01
This study aims to provide an analytical overview of the changing burden of colorectal cancer and highlight the implementable control measures that can help reduce the future burden of colorectal cancer in Malaysia. We performed a MEDLINE search via OVID with the Medical Subject Headings (MeSH) terms "Colorectal Neoplasms"[Mesh] and "Malaysia"[Mesh], and PubMed with the key words "colorectal cancer" and "Malaysia" from 1990 to 2015 for studies reporting any clinical, societal, and economical findings associated with colorectal cancer in Malaysia. Incidence and mortality data were retrieved from population-based cancer registries/databases. In Malaysia, colorectal cancer is the second most common cancer in males and the third most common cancer in females. The economic burden of colorectal cancer is substantial and is likely to increase over time in Malaysia owing to the current trend in colorectal cancer incidence. In Malaysia, most patients with colorectal cancer have been diagnosed at a late stage, with the 5-year relative survival by stage being lower than that in developed Asian countries. Public awareness of the rising incidence of colorectal cancer and the participation rates for colorectal cancer screening are low. The efficiency of different screening approaches must be assessed, and an organized national screening program should be developed in a phased manner. It is essential to maintain a balanced investment in awareness programs targeting general population and primary care providers, focused on increasing the knowledge on symptoms and risk factors of colorectal cancer, awareness on benefits of screening, and promotion of healthy life styles to prevent this important disease. Copyright © 2016. Published by Elsevier Taiwan.
A Parallel Ghosting Algorithm for The Flexible Distributed Mesh Database
Mubarak, Misbah; Seol, Seegyoung; Lu, Qiukai; ...
2013-01-01
Critical to the scalability of parallel adaptive simulations are parallel control functions including load balancing, reduced inter-process communication and optimal data decomposition. In distributed meshes, many mesh-based applications frequently access neighborhood information for computational purposes which must be transmitted efficiently to avoid parallel performance degradation when the neighbors are on different processors. This article presents a parallel algorithm of creating and deleting data copies, referred to as ghost copies, which localize neighborhood data for computation purposes while minimizing inter-process communication. The key characteristics of the algorithm are: (1) It can create ghost copies of any permissible topological order in amore » 1D, 2D or 3D mesh based on selected adjacencies. (2) It exploits neighborhood communication patterns during the ghost creation process thus eliminating all-to-all communication. (3) For applications that need neighbors of neighbors, the algorithm can create n number of ghost layers up to a point where the whole partitioned mesh can be ghosted. Strong and weak scaling results are presented for the IBM BG/P and Cray XE6 architectures up to a core count of 32,768 processors. The algorithm also leads to scalable results when used in a parallel super-convergent patch recovery error estimator, an application that frequently accesses neighborhood data to carry out computation.« less
Simón-Allué, R; Ortillés, A; Calvo, B
2018-06-01
Despite the widespread use of synthetic meshes in the surgical treatment of the hernia pathology, the election criteria of a suitable mesh for specific patient continues to be uncertain. Thus, in this work, we propose a methodology to determine in advance potential disadvantages on the use of certain meshes based on the patient-specific abdominal geometry and the mechanical features of the certain meshes. To that purpose, we have first characterized the mechanical behavior of four synthetic meshes through biaxial tests. Secondly, two of these meshes were implanted in several New Zealand rabbits with a total defect previously created on the center of the abdominal wall. After the surgical procedure, specimen were subjected to in vivo pneumoperitoneum tests to determine the immediate post-surgical response of those meshes after implanted in a healthy specimen. Experimental performance was recorded by a stereo rig with the aim of obtaining quantitative information about the pressure-displacement relation of the abdominal wall. Finally, following the procedure presented in prior works (Simón-Allué et al., 2015, 2017), a finite element model was reconstructed from the experimental measurements and tests were computationally reproduced for the healthy and herniated cases. Simulations were compared and validated with the in vivo behavior and results were given along the abdominal wall in terms of displacements, stresses and strain. Mechanical characterization of the meshes revealed Surgipro TM as the most rigid implant and Neomesh SuperSoft® as the softer, while other two meshes (Neomesh Soft®, Neopore®) remained in between. These two meshes were employed in the experimental study and resulted in similar effect in the abdominal wall cavity and both were close to the healthy case. Simulations confirmed this result while showed potential objections in the case of the other two meshes, due to high values in stresses or elongation that may led to discomfort in real tissue. The use of this methodology on human surgery may provide the surgeons with reliable and useful information to avoid certain meshes on specific-patient treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Hoerz, Friedrich; Cintala, Mark J.; Bernhard, Ronald P.; Cardenas, Frank; Davidson, William; Haynes, Gerald; See, Thomas H.; Winkler, Jerry; Gray, Barry
1993-01-01
The utility of multiple-mesh targets as potential lightweight shields to protect spacecraft in low-Earth orbit against collisional damage is explored. Earlier studies revealed that single meshes comminute hypervelocity impactors with efficiencies comparable to contiguous targets. Multiple interaction of projectile fragments with any number of meshes should lead to increased comminution, deceleration, and dispersion of the projectile, such that all debris exiting the mesh stack possesses low specific energies (ergs/sq cm) that would readily be tolerated by many flight systems. The study is conceptually exploring the sensitivity of major variables such as impact velocity, the specific areal mass (g/sq cm) of the total mesh stack (SM), and the separation distance (S) between individual meshes. Most experiments employed five or ten meshes with total SM typically less than 0.5 the specific mass of the impactor, and silicate glass impactors rather than metal projectiles. While projectile comminution increases with increasing impact velocity due to progressively higher shock stresses, encounters with multiple-meshes at low velocity (1-2 km/s) already lead to significant disruption of the glass impactors, with the resulting fragments being additionally decelerated and dispersed by subsequent meshes, and, unlike most contiguous single-plate bumpers, leading to respectable performance at low velocity. Total specific bumper mass must be the subject of careful trade-off studies; relatively massive bumpers will generate too much debris being dislodged from the bumper itself, while exceptionally lightweight designs will not cause sufficient comminution, deceleration, or dispersion of the impactor. Separation distance was found to be a crucial design parameter, as it controls the dispersion of the fragment cloud. Substantial mass savings could result if maximum separation distances were employed. The total mass of debris dislodged by multiple-mesh stacks is modestly smaller than that of single, contiguous-membrane shields. The cumulative surface area of all penetration holes in multiple mesh stacks is an order of magnitude smaller than that in analog multiple-foil shields, suggesting good long-term performance of the mesh designs. Due to different experimental conditions, direct and quantitative comparison with other lightweight shields is not possible at present.
Intermediate view synthesis algorithm using mesh clustering for rectangular multiview camera system
NASA Astrophysics Data System (ADS)
Choi, Byeongho; Kim, Taewan; Oh, Kwan-Jung; Ho, Yo-Sung; Choi, Jong-Soo
2010-02-01
A multiview video-based three-dimensional (3-D) video system offers a realistic impression and a free view navigation to the user. The efficient compression and intermediate view synthesis are key technologies since 3-D video systems deal multiple views. We propose an intermediate view synthesis using a rectangular multiview camera system that is suitable to realize 3-D video systems. The rectangular multiview camera system not only can offer free view navigation both horizontally and vertically but also can employ three reference views such as left, right, and bottom for intermediate view synthesis. The proposed view synthesis method first represents the each reference view to meshes and then finds the best disparity for each mesh element by using the stereo matching between reference views. Before stereo matching, we separate the virtual image to be synthesized into several regions to enhance the accuracy of disparities. The mesh is classified into foreground and background groups by disparity values and then affine transformed. By experiments, we confirm that the proposed method synthesizes a high-quality image and is suitable for 3-D video systems.
First benchmark of the Unstructured Grid Adaptation Working Group
NASA Technical Reports Server (NTRS)
Ibanez, Daniel; Barral, Nicolas; Krakos, Joshua; Loseille, Adrien; Michal, Todd; Park, Mike
2017-01-01
Unstructured grid adaptation is a technology that holds the potential to improve the automation and accuracy of computational fluid dynamics and other computational disciplines. Difficulty producing the highly anisotropic elements necessary for simulation on complex curved geometries that satisfies a resolution request has limited this technology's widespread adoption. The Unstructured Grid Adaptation Working Group is an open gathering of researchers working on adapting simplicial meshes to conform to a metric field. Current members span a wide range of institutions including academia, industry, and national laboratories. The purpose of this group is to create a common basis for understanding and improving mesh adaptation. We present our first major contribution: a common set of benchmark cases, including input meshes and analytic metric specifications, that are publicly available to be used for evaluating any mesh adaptation code. We also present the results of several existing codes on these benchmark cases, to illustrate their utility in identifying key challenges common to all codes and important differences between available codes. Future directions are defined to expand this benchmark to mature the technology necessary to impact practical simulation workflows.
An appraisal of the literature on teaching physical examination skills.
Easton, Graham; Stratford-Martin, James; Atherton, Helen
2012-07-01
To discover which models for teaching physical examination skills have been proposed, and to appraise the evidence for each. We conducted a narrative review of relevant literature from 1990-2010. We searched the databases MEDLINE, PsycINFO, and ERIC (The Education Resource Information Centre) for the terms: 'physical examination' AND 'teaching' as both MESH terms and keyword searches. We excluded web-based or video teaching, non-physical examination skills (e.g. communication skills), and articles about simulated patients or models. We identified five relevant articles. These five studies outlined several approaches to teaching physical examination skills, including Peyton's 4-step model, an adaptation of his model to a 6-step model; the silent run through; and collaborative discovery. There was little evidence to support one method over others. One controlled trial suggested that silent run-through could improve performance of complex motor tasks, and another suggested that collaborative discovery improves students' ability to recognise key findings in cardiac examinations. There are several models for teaching physical examinations, but few are designed specifically for that purpose and there is little evidence to back any one model over another. We propose an approach which adopts several key features of these models. Future research could usefully evaluate the effectiveness of the proposed models, or develop innovative practical models for teaching examination skills.
Grubnik, Vladimir V; Grubnik, Aleksandra V; Vorotyntseva, Kseniya O
2014-06-01
Laparoscopic incisional and ventral hernia repair (LIVHR) was first reported by Le Blanc and Booth in 1993. Many studies are available in the literature that have shown that laparoscopic repair of incisional and ventral hernia is preferred over open repair because of lower recurrence rates (less than 10%), less wound morbidity, less pain, and early return to work. To identify the long-term outcomes between the different types of meshes and two techniques of mesh fixation, i.e., tacks (method Double crown) and transfascial polypropylene sutures. A total of 92 patients underwent LIVHR at our department between January 2009 and August 2012. The hernias were umbilical in 26 patients, paraumbilical in 15 patients and incisional in 51 patients. All patients admitted for LIVHR were randomized to either group I (tacker fixation of ePTFE meshes) or group II (suture fixation of meshes with nitinol frame) using computer-generated random numbers with block randomization and sealed envelopes for concealed allocation. The mean mesh fixation time was significantly higher in the tacker fixation group (117 ±15 min vs. 72 ±6 min, p < 0.01). There were no conversions in either group. The median postoperative hospital stay was 3.5 ±1.5 days. All patients were followed up at 1, 3, 6, 12 and every 6 months thereafter postoperatively. There were 5 recurrences in the study population. In group I there were 4 patients with recurrence, and only 1 patient in the group with meshes with a nitinol frame. Meshes of the new generation with a nitinol framework can significantly improve laparoscopic ventral hernia repair. The fixation of these meshes is very simple using 3-4 transfascial sutures. The absence of shrinkage of these meshes makes the probability of recurrence minimal. Absence of tackers allows postoperative pain to be minimized. We consider that these new meshes can significantly improve laparoscopic ventral hernia repair.
Robinson, Judas; de Lusignan, Simon; Kostkova, Patty; Madge, Bruce
2006-01-01
The Metathesaurus of the Unified Medical Language System (UMLS) offers the possibility of mapping between various medical vocabularies. The Primary Care Electronic Library (PCEL) contains a database of over six thousand Medical Subject Headings (MeSH terms) describing the resources of the electronic library. We were interested to know if it was possible to map from MeSH to the Systemized Nomenclature of Medicine Clinical Terms (SNOMED CT). Such a mapping would aid healthcare professionals to retrieve relevant data from our digital library as it would enable links between clinical systems and indexed material.
Ferraris, Victor A; Brown, Jeremiah R; Despotis, George J; Hammon, John W; Reece, T Brett; Saha, Sibu P; Song, Howard K; Clough, Ellen R; Shore-Lesserson, Linda J; Goodnough, Lawrence T; Mazer, C David; Shander, Aryeh; Stafford-Smith, Mark; Waters, Jonathan; Baker, Robert A; Dickinson, Timothy A; FitzGerald, Daniel J; Likosky, Donald S; Shann, Kenneth G
2011-03-01
Practice guidelines reflect published literature. Because of the ever changing literature base, it is necessary to update and revise guideline recommendations from time to time. The Society of Thoracic Surgeons recommends review and possible update of previously published guidelines at least every three years. This summary is an update of the blood conservation guideline published in 2007. The search methods used in the current version differ compared to the previously published guideline. Literature searches were conducted using standardized MeSH terms from the National Library of Medicine PUBMED database list of search terms. The following terms comprised the standard baseline search terms for all topics and were connected with the logical 'OR' connector--Extracorporeal circulation (MeSH number E04.292), cardiovascular surgical procedures (MeSH number E04.100), and vascular diseases (MeSH number C14.907). Use of these broad search terms allowed specific topics to be added to the search with the logical 'AND' connector. In this 2011 guideline update, areas of major revision include: 1) management of dual anti-platelet therapy before operation, 2) use of drugs that augment red blood cell volume or limit blood loss, 3) use of blood derivatives including fresh frozen plasma, Factor XIII, leukoreduced red blood cells, platelet plasmapheresis, recombinant Factor VII, antithrombin III, and Factor IX concentrates, 4) changes in management of blood salvage, 5) use of minimally invasive procedures to limit perioperative bleeding and blood transfusion, 6) recommendations for blood conservation related to extracorporeal membrane oxygenation and cardiopulmonary perfusion, 7) use of topical hemostatic agents, and 8) new insights into the value of team interventions in blood management. Much has changed since the previously published 2007 STS blood management guidelines and this document contains new and revised recommendations. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
An adaptively refined XFEM with virtual node polygonal elements for dynamic crack problems
NASA Astrophysics Data System (ADS)
Teng, Z. H.; Sun, F.; Wu, S. C.; Zhang, Z. B.; Chen, T.; Liao, D. M.
2018-02-01
By introducing the shape functions of virtual node polygonal (VP) elements into the standard extended finite element method (XFEM), a conforming elemental mesh can be created for the cracking process. Moreover, an adaptively refined meshing with the quadtree structure only at a growing crack tip is proposed without inserting hanging nodes into the transition region. A novel dynamic crack growth method termed as VP-XFEM is thus formulated in the framework of fracture mechanics. To verify the newly proposed VP-XFEM, both quasi-static and dynamic cracked problems are investigated in terms of computational accuracy, convergence, and efficiency. The research results show that the present VP-XFEM can achieve good agreement in stress intensity factor and crack growth path with the exact solutions or experiments. Furthermore, better accuracy, convergence, and efficiency of different models can be acquired, in contrast to standard XFEM and mesh-free methods. Therefore, VP-XFEM provides a suitable alternative to XFEM for engineering applications.
MRI Guided Brain Stimulation without the Use of a Neuronavigation System
Vaghefi, Ehsan; Byblow, Winston D.; Stinear, Cathy M.; Thompson, Benjamin
2015-01-01
A key issue in the field of noninvasive brain stimulation (NIBS) is the accurate localization of scalp positions that correspond to targeted cortical areas. The current gold standard is to combine structural and functional brain imaging with a commercially available “neuronavigation” system. However, neuronavigation systems are not commonplace outside of specialized research environments. Here we describe a technique that allows for the use of participant-specific functional and structural MRI data to guide NIBS without a neuronavigation system. Surface mesh representations of the head were generated using Brain Voyager and vectors linking key anatomical landmarks were drawn on the mesh. Our technique was then used to calculate the precise distances on the scalp corresponding to these vectors. These calculations were verified using actual measurements of the head and the technique was used to identify a scalp position corresponding to a brain area localized using functional MRI. PMID:26413537
Nune, K C; Kumar, A; Misra, R D K; Li, S J; Hao, Y L; Yang, R
2017-02-01
We elucidate here the osteoblasts functions and cellular activity in 3D printed interconnected porous architecture of functionally gradient Ti-6Al-4V alloy mesh structures in terms of cell proliferation and growth, distribution of cell nuclei, synthesis of proteins (actin, vinculin, and fibronectin), and calcium deposition. Cell culture studies with pre-osteoblasts indicated that the interconnected porous architecture of functionally gradient mesh arrays was conducive to osteoblast functions. However, there were statistically significant differences in the cellular response depending on the pore size in the functionally gradient structure. The interconnected porous architecture contributed to the distribution of cells from the large pore size (G1) to the small pore size (G3), with consequent synthesis of extracellular matrix and calcium precipitation. The gradient mesh structure significantly impacted cell adhesion and influenced the proliferation stage, such that there was high distribution of cells on struts of the gradient mesh structure. Actin and vinculin showed a significant difference in normalized expression level of protein per cell, which was absent in the case of fibronectin. Osteoblasts present on mesh struts formed a confluent sheet, bridging the pores through numerous cytoplasmic extensions. The gradient mesh structure fabricated by electron beam melting was explored to obtain fundamental insights on cellular activity with respect to osteoblast functions. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Jiang, Bin; Zhang, Hongjie; Sun, Yongli; Zhang, Luhong; Xu, Lidong; Hao, Li; Yang, Huawei
2017-06-01
A superhydrophobic and superoleophilic stainless steel (SS) mesh for oil/water separation has been developed by using a novel, facile and inexpensive covalent layer-by-layer grafting (LBLG) method. Hierarchical micro/nanostructure surface was formed through grafting the (3-aminopropyl) triethoxysilane (SCA), polyethylenimine (PEI) and trimesoyl chloride (TMC) onto the mesh in sequence, accompanied with SiO2 nanoparticles subtly and firmly anchored in multilayers. Superhydrophobic characteristic was realized by self-assembly grafting of hydrophobic groups onto the surface. The as-prepared mesh exhibits excellent superhydrophobicity with a water contact angle of 159°. Moreover, with a low sliding angle of 4°, it shows the "lotus effect" for self-cleaning. As for application evaluation, the as-prepared mesh can be used for large-scale separation of oil/water mixtures with a relatively high separation efficiency after 30 times reuse (99.88% for n-octane/water mixture) and a high intrusion pressure (3.58 kPa). More importantly, the mesh exhibited excellent stability in the case of vibration situation, long-term storage as well as saline corrosion conditions, and the compatible pH range was determined to be 1-13. In summary, this work provides a brand new method of modifying SS mesh in a covalent LBLG way, and makes it possible to introduce various functionalized groups onto the surface.
A priori mesh grading for the numerical calculation of the head-related transfer functions
Ziegelwanger, Harald; Kreuzer, Wolfgang; Majdak, Piotr
2017-01-01
Head-related transfer functions (HRTFs) describe the directional filtering of the incoming sound caused by the morphology of a listener’s head and pinnae. When an accurate model of a listener’s morphology exists, HRTFs can be calculated numerically with the boundary element method (BEM). However, the general recommendation to model the head and pinnae with at least six elements per wavelength renders the BEM as a time-consuming procedure when calculating HRTFs for the full audible frequency range. In this study, a mesh preprocessing algorithm is proposed, viz., a priori mesh grading, which reduces the computational costs in the HRTF calculation process significantly. The mesh grading algorithm deliberately violates the recommendation of at least six elements per wavelength in certain regions of the head and pinnae and varies the size of elements gradually according to an a priori defined grading function. The evaluation of the algorithm involved HRTFs calculated for various geometric objects including meshes of three human listeners and various grading functions. The numerical accuracy and the predicted sound-localization performance of calculated HRTFs were analyzed. A-priori mesh grading appeared to be suitable for the numerical calculation of HRTFs in the full audible frequency range and outperformed uniform meshes in terms of numerical errors, perception based predictions of sound-localization performance, and computational costs. PMID:28239186
Hiatal hernia repair with gore bio-a tissue reinforcement: our experience.
Antonino, Agrusa; Giorgio, Romano; Giuseppe, Frazzetta; Giovanni, De Vita; Silvia, Di Giovanni; Daniela, Chianetta; Giuseppe, Di Buono; Vincenzo, Sorce; Gaspare, Gulotta
2014-01-01
Type I hiatal hernia is associated with gastroesophageal reflux disease (GERD) in 50-90% of cases. Several trials strongly support surgery as an effective alternative to medical therapy. Today, laparoscopic fundoplication is considered as the procedure of choice. However, primary laparoscopic hiatal hernia repair is associated with upto 42% recurrence rate. Mesh reinforcement of the crural closure decreases the recurrence but can lead to complications, above all nonabsorbable ones. We experiment a new totally absorbable mesh by Gore. Case. We present a case of a 65-year-old female patient with a 6-year classic history of GERD. Endoscopy revealed a large hiatal hernia and esophagitis. pH study was positive for acid reflux; esophageal manometry revealed LES intrathoracic dislocation. With laparoscopic approach, the hiatal hernia defect was identified and primarily repaired, by crural closure. Gore Bio-A Tissue Reinforcement was trimmed to fit the defect accommodating the esophagus. Nissen fundoplication was performed. Result. Bio-A mesh was easily placed laparoscopically. It has good handling and could be cut and tailored intraoperatively for optimal adaptation. There were no short-term complications. Conclusion. Crural closure reinforcement can be done readily with this new totally absorbable mesh replaced by soft tissue over six months. However, further data and studies are needed to evaluate long-term outcomes.
Hiatal Hernia Repair with Gore Bio-A Tissue Reinforcement: Our Experience
Antonino, Agrusa; Giorgio, Romano; Giuseppe, Frazzetta; Giovanni, De Vita; Silvia, Di Giovanni; Daniela, Chianetta; Giuseppe, Di Buono; Vincenzo, Sorce; Gaspare, Gulotta
2014-01-01
Type I hiatal hernia is associated with gastroesophageal reflux disease (GERD) in 50–90% of cases. Several trials strongly support surgery as an effective alternative to medical therapy. Today, laparoscopic fundoplication is considered as the procedure of choice. However, primary laparoscopic hiatal hernia repair is associated with upto 42% recurrence rate. Mesh reinforcement of the crural closure decreases the recurrence but can lead to complications, above all nonabsorbable ones. We experiment a new totally absorbable mesh by Gore. Case. We present a case of a 65-year-old female patient with a 6-year classic history of GERD. Endoscopy revealed a large hiatal hernia and esophagitis. pH study was positive for acid reflux; esophageal manometry revealed LES intrathoracic dislocation. With laparoscopic approach, the hiatal hernia defect was identified and primarily repaired, by crural closure. Gore Bio-A Tissue Reinforcement was trimmed to fit the defect accommodating the esophagus. Nissen fundoplication was performed. Result. Bio-A mesh was easily placed laparoscopically. It has good handling and could be cut and tailored intraoperatively for optimal adaptation. There were no short-term complications. Conclusion. Crural closure reinforcement can be done readily with this new totally absorbable mesh replaced by soft tissue over six months. However, further data and studies are needed to evaluate long-term outcomes. PMID:24864221
Petter-Puchner, A; Gruber-Blum, S; Walder, N; Fortelny, R H; Redl, H; Raum, K
2014-08-01
Mesh integration is a key parameter for reliable and safe hernia repair. So far, its assessment is based on histology obtained from rare second-look operations or experimental research. Therefore, non-invasive high-resolution imaging techniques would be of great value. Ultrasound biomicroscopy (UBM) and scanning acoustic microscopy (SAM) have shown potential in the imaging of hard and soft tissues. This experimental study compared the detection of mesh integration, foreign body reaction and scar formation in UBM/SAM with standard histology. Ten titanized polypropylene meshes were implanted in rats in a model of onlay repair. 17 days postoperative animals were killed and samples were paraffin embedded for histology (H&E, Cresyl violet) or processed for postmortem UBM/SAM. The observation period was uneventful and meshes appeared well integrated. Relocation of neighboring cross-sectional levels could easily be achieved with the 40-MHz UBM and granulation tissue could be distinguished from adjacent muscle tissue layers. The spatial resolution of approximately 8 μm of the 200-MHz UBM system images was comparable to standard histology (2.5-5× magnification) and allowed a clear identification of mesh fibers and different tissue types, e.g., scar, fat, granulation, and muscle tissues, as well as vessels, abscedations, and foreign body giant cell clusters. This pilot study demonstrates the potential of high-frequency ultrasound to assess hernia mesh integration non-invasively. Although the methods lack cell-specific information, tissue integration could reliably be assessed. The possibility of conducting UBM in vivo advocates this method as a guidance tool for the indication of second-look operations and subsequent elaborate histological analyses.
NASA Astrophysics Data System (ADS)
Ji, X.; Shen, C.
2017-12-01
Flood inundation presents substantial societal hazards and also changes biogeochemistry for systems like the Amazon. It is often expensive to simulate high-resolution flood inundation and propagation in a long-term watershed-scale model. Due to the Courant-Friedrichs-Lewy (CFL) restriction, high resolution and large local flow velocity both demand prohibitively small time steps even for parallel codes. Here we develop a parallel surface-subsurface process-based model enhanced by multi-resolution meshes that are adaptively switched on or off. The high-resolution overland flow meshes are enabled only when the flood wave invades to floodplains. This model applies semi-implicit, semi-Lagrangian (SISL) scheme in solving dynamic wave equations, and with the assistant of the multi-mesh method, it also adaptively chooses the dynamic wave equation only in the area of deep inundation. Therefore, the model achieves a balance between accuracy and computational cost.
3D Reconstruction of human bones based on dictionary learning.
Zhang, Binkai; Wang, Xiang; Liang, Xiao; Zheng, Jinjin
2017-11-01
An effective method for reconstructing a 3D model of human bones from computed tomography (CT) image data based on dictionary learning is proposed. In this study, the dictionary comprises the vertices of triangular meshes, and the sparse coefficient matrix indicates the connectivity information. For better reconstruction performance, we proposed a balance coefficient between the approximation and regularisation terms and a method for optimisation. Moreover, we applied a local updating strategy and a mesh-optimisation method to update the dictionary and the sparse matrix, respectively. The two updating steps are iterated alternately until the objective function converges. Thus, a reconstructed mesh could be obtained with high accuracy and regularisation. The experimental results show that the proposed method has the potential to obtain high precision and high-quality triangular meshes for rapid prototyping, medical diagnosis, and tissue engineering. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
DigiMesh Reliability in High Speed Vehicular Applications
NASA Astrophysics Data System (ADS)
Visan, Bogdan A.
In a fast-paced technological society, advances in wireless networking show potential to save lives. Communication is key to notifying Emergency Medical Services of a potentially deadly accident in near real-time. This paper will discuss the use of low powered wireless devices transmitting life-saving information autonomously. Current and planned technologies used in vehicles are built-in, costly, and vulnerable to physical destruction. Using an independent system can offer both old and new vehicles primary and secondary communication. The results from this research study show that vehicles can use DigiMesh as a viable solution, although relative velocity affects its performance.
Incisional hernia prevention using a cyanoacrilate-fixed retrofascial mesh.
Hoyuela, Carlos; Juvany, Montserrat; Trias, Miquel; Ardid, Jordi; Martrat, Antoni
2018-01-01
The rate of incisional hernia in high-risk patients (obesity, cancer, etc.) is high, even in laparoscopic surgery. The aim of this study is to evaluate the safety of the use of cyanoacrylate fixed prophylactic meshes in the assistance incision in overweight or obese patients undergoing laparoscopic colorectal surgery. A prospective, non-randomized cohort study of patients undergoing elective laparoscopic resection for colorectal cancer between January 2013 and March 2016 was performed. Those with a body mass index greater than 25kg / m 2 were evaluated to implant a prophylactic meshes fixed with cyanoacrylate (Histoacryl®) as reinforcement of the assistance incision. 52 patients were analyzed (mean body mass index: 28.4±2kg / m 2 ). Prophylactic meshes was implanted in 15 patients. The time to put the mesh in place was always less than 5minutes. There was no significant difference in wound infection rate (12% vs. 10%). No mesh had to be explanted. Although the mean follow-up was shorter (14.1±4 vs. 22.3±9 months), there were no incisional hernia in the mesh group. On the other hand, in the non-mesh group, 1 acute evisceration (2.7%) and 4 incisional hernia of the assistance incision were observed (10.8%). There were no significant differences between groups regarding trocar incisional hernia (6.6 vs. 5.4%). The implantation of a reinforcement prophylactic mesh in overweight or obese patients undergoing laparoscopic colorectal surgery is safe and seems to reduce the short-term rate of incisional hernia. Fixation with cyanoacrylate is a rapid method that facilitates the procedure without additional complications. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
[Skeleton extractions and applications].
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quadros, William Roshan
2010-05-01
This paper focuses on the extraction of skeletons of CAD models and its applications in finite element (FE) mesh generation. The term 'skeleton of a CAD model' can be visualized as analogous to the 'skeleton of a human body'. The skeletal representations covered in this paper include medial axis transform (MAT), Voronoi diagram (VD), chordal axis transform (CAT), mid surface, digital skeletons, and disconnected skeletons. In the literature, the properties of a skeleton have been utilized in developing various algorithms for extracting skeletons. Three main approaches include: (1) the bisection method where the skeleton exists at equidistant from at leastmore » two points on boundary, (2) the grassfire propagation method in which the skeleton exists where the opposing fronts meet, and (3) the duality method where the skeleton is a dual of the object. In the last decade, the author has applied different skeletal representations in all-quad meshing, hex meshing, mid-surface meshing, mesh size function generation, defeaturing, and decomposition. A brief discussion on the related work from other researchers in the area of tri meshing, tet meshing, and anisotropic meshing is also included. This paper concludes by summarizing the strengths and weaknesses of the skeleton-based approaches in solving various geometry-centered problems in FE mesh generation. The skeletons have proved to be a great shape abstraction tool in analyzing the geometric complexity of CAD models as they are symmetric, simpler (reduced dimension), and provide local thickness information. However, skeletons generally require some cleanup, and stability and sensitivity of the skeletons should be controlled during extraction. Also, selecting a suitable application-specific skeleton and a computationally efficient method of extraction is critical.« less
An Opportunistic Routing Mechanism Combined with Long-Term and Short-Term Metrics for WMN
Piao, Xianglan; Qiu, Tie
2014-01-01
WMN (wireless mesh network) is a useful wireless multihop network with tremendous research value. The routing strategy decides the performance of network and the quality of transmission. A good routing algorithm will use the whole bandwidth of network and assure the quality of service of traffic. Since the routing metric ETX (expected transmission count) does not assure good quality of wireless links, to improve the routing performance, an opportunistic routing mechanism combined with long-term and short-term metrics for WMN based on OLSR (optimized link state routing) and ETX is proposed in this paper. This mechanism always chooses the highest throughput links to improve the performance of routing over WMN and then reduces the energy consumption of mesh routers. The simulations and analyses show that the opportunistic routing mechanism is better than the mechanism with the metric of ETX. PMID:25250379
An opportunistic routing mechanism combined with long-term and short-term metrics for WMN.
Sun, Weifeng; Wang, Haotian; Piao, Xianglan; Qiu, Tie
2014-01-01
WMN (wireless mesh network) is a useful wireless multihop network with tremendous research value. The routing strategy decides the performance of network and the quality of transmission. A good routing algorithm will use the whole bandwidth of network and assure the quality of service of traffic. Since the routing metric ETX (expected transmission count) does not assure good quality of wireless links, to improve the routing performance, an opportunistic routing mechanism combined with long-term and short-term metrics for WMN based on OLSR (optimized link state routing) and ETX is proposed in this paper. This mechanism always chooses the highest throughput links to improve the performance of routing over WMN and then reduces the energy consumption of mesh routers. The simulations and analyses show that the opportunistic routing mechanism is better than the mechanism with the metric of ETX.
Local meshing plane analysis as a source of information about the gear quality
NASA Astrophysics Data System (ADS)
Mączak, Jędrzej
2013-07-01
In the paper the application of the local meshing plane concept is discussed and applied for detecting of tooth degradation due to fatigue, and for overall gear quality assessment. Knowing the kinematic properties of the machine (i.e. gear tooth numbers) it is possible to modify the diagnostic signal in such a manner that its fragments will be linked to different rotating parts. This allows for presentation of either raw or processed gearbox signal in a form of three dimensional map on the plane "pinion teeth×gear teeth", called local meshing plane. The meshing plane in Cartesian coordinates z1×z2 allows for precise location and assessment of gear faults in terms of meshing quality of consecutive tooth pairs. Although the method was applied to simulated signals generated by the gearbox model, similar results were obtained for the measurement signals recorded during the back-to-back test stand experiment. The described method could be used for assessing the manufacturing quality of gears, the assembly quality as well as for the gear failure evaluation during normal exploitation.
Lo, Tsia-Shu; Pue, Leng Boi; Tan, Yiap Loong; Wu, Pei-Ying
2014-02-01
Anterior vaginal mesh (AVM) combined with sacrospinous ligament fixation (SSF) yields better long-term success rates over anterior colporrhaphy (AC) in advanced pelvic organ prolapse (POP) surgery, with a low rate of mesh-related complications. Medical records of 198 patients who underwent surgery for POP between January 2006 and March 2010 were reviewed retrospectively. Patients' assessment at baseline and third-year postoperative follow-up were analyzed. SSF plus AC or AVM was performed for apical and anterior compartment repair. Primary outcome was objective cure [Pelvic Organ Prolapse Quantification (POP-Q) stage ≤ 1)], and subjective cure defined as negative response to questions 2 and 3 on the POPDI-6. Secondary outcomes were complications, symptoms severity and quality of life as measured with validated questionnaires. Post-operative data were available for 186 patients, 72 in AC group and 114 in AVM group were analyzed. The mean age, parity and operating time in AVM group were significantly higher as compared to AC group. The overall objective and subjective cure rate in AVM group was significantly higher than AC group (90.3 % and 88.6 % versus 73.6 % and 70.8 %, with P value = 0.003 and 0.002 respectively). Mesh exposure rate was 3.5 %. Improvement in both POPDI-6 and PISQ-12 in AVM group was statistically significant compared to AC group. Transobturator synthetic nonabsorbable AVM combined with SSF yielded a favorable and sustainable result over 5 years as compared to traditional AC, both in anatomical and subjective success rate. Mesh related morbidities were low and acceptable.
Long-term outcome for open preperitoneal mesh repair of recurrent inguinal hernia.
Yang, Bin; Jiang, Zhi-peng; Li, Ying-ru; Zong, Zhen; Chen, Shuang
2015-07-01
Recurrent inguinal hernia represents a major challenge for surgeons with high risks of re-recurrence and complications, especially when an anterior approach is adopted. The aim of this study was to evaluate the long-term results of the open preperitoneal mesh repair for recurrent inguinal hernia. We performed a prospective clinical study of 107 consecutive patients having recurrent inguinal hernias between April 2006 and November 2010. All patients were operated on using open preperitoneal mesh repair. The demographics, perioperative variables, complications and recurrences were evaluated with all patients. There were no major intraoperative complications. The average operative time was 42.1 min (range 28-83 min) for unilateral and 62.7 min (range 38-106 min) for bilateral hernias. The mean postoperative hospital stay was 1.6 days (range 1-9 days). The overall complication rate was 8.4%. There were two superficial wound infections, two groin seroma and three urinary retention. The mean follow-up time was 42.3 months (range 28-73 months), three patients developed hernia recurrence. No testicular, chronic pain or mesh-related complications were noted in these series. Open posterior preperitoneal mesh repair offers a viable option for recurrent inguinal hernias and achieves equally effective results to laparoscopic approaches with acceptable complication and recurrence rates. It is safer and easier to learn than laparoscopic repair and has become the preferred approach for treatment of the majority of recurrent inguinal hernias at our institution, especially useful for complex multirecurrent hernias and patients with cardiopulmonary insufficiency. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Becker, P.; Idelsohn, S. R.; Oñate, E.
2015-06-01
This paper describes a strategy to solve multi-fluid and fluid-structure interaction (FSI) problems using Lagrangian particles combined with a fixed finite element (FE) mesh. Our approach is an extension of the fluid-only PFEM-2 (Idelsohn et al., Eng Comput 30(2):2-2, 2013; Idelsohn et al., J Numer Methods Fluids, 2014) which uses explicit integration over the streamlines to improve accuracy. As a result, the convective term does not appear in the set of equations solved on the fixed mesh. Enrichments in the pressure field are used to improve the description of the interface between phases.
NASA Astrophysics Data System (ADS)
Caniza, Horacio; Romero, Alfonso E.; Paccanaro, Alberto
2015-12-01
We introduce a MeSH-based method that accurately quantifies similarity between heritable diseases at molecular level. This method effectively brings together the existing information about diseases that is scattered across the vast corpus of biomedical literature. We prove that sets of MeSH terms provide a highly descriptive representation of heritable disease and that the structure of MeSH provides a natural way of combining individual MeSH vocabularies. We show that our measure can be used effectively in the prediction of candidate disease genes. We developed a web application to query more than 28.5 million relationships between 7,574 hereditary diseases (96% of OMIM) based on our similarity measure.
Adapting to life: ocean biogeochemical modelling and adaptive remeshing
NASA Astrophysics Data System (ADS)
Hill, J.; Popova, E. E.; Ham, D. A.; Piggott, M. D.; Srokosz, M.
2013-11-01
An outstanding problem in biogeochemical modelling of the ocean is that many of the key processes occur intermittently at small scales, such as the sub-mesoscale, that are not well represented in global ocean models. As an example, state-of-the-art models give values of primary production approximately two orders of magnitude lower than those observed in the ocean's oligotrophic gyres, which cover a third of the Earth's surface. This is partly due to their failure to resolve sub-mesoscale phenomena, which play a significant role in nutrient supply. Simply increasing the resolution of the models may be an inefficient computational solution to this problem. An approach based on recent advances in adaptive mesh computational techniques may offer an alternative. Here the first steps in such an approach are described, using the example of a~simple vertical column (quasi 1-D) ocean biogeochemical model. We present a novel method of simulating ocean biogeochemical behaviour on a vertically adaptive computational mesh, where the mesh changes in response to the biogeochemical and physical state of the system throughout the simulation. We show that the model reproduces the general physical and biological behaviour at three ocean stations (India, Papa and Bermuda) as compared to a high-resolution fixed mesh simulation and to observations. The simulations capture both the seasonal and inter-annual variations. The use of an adaptive mesh does not increase the computational error, but reduces the number of mesh elements by a factor of 2-3, so reducing computational overhead. We then show the potential of this method in two case studies where we change the metric used to determine the varying mesh sizes in order to capture the dynamics of chlorophyll at Bermuda and sinking detritus at Papa. We therefore demonstrate adaptive meshes may provide a~suitable numerical technique for simulating seasonal or transient biogeochemical behaviour at high spatial resolution whilst minimising computational cost.
Bresnahan, Erin; Bates, Andrew; Wu, Andrew; Reiner, Mark; Jacob, Brian
2015-09-01
The use of self-gripping mesh during laparoscopic TEP inguinal hernia repairs may eliminate the need for any additional fixation, and thus reduce post-operative pain without the added concern for mesh migration. Long-term outcomes are not yet prospectively studied in a controlled fashion. Under IRB approval, from January 2011-April 2013, 91 hernias were repaired laparoscopically with self-gripping mesh without additional fixation. Patients were followed for at least 1 year. Demographics and intraoperative data (defect location, size, and mesh deployment time) are recorded. VAS is used in the recovery room (RR) to score pain, and the Carolinas Comfort Scale ™ (CCS), a validated 0-5 pain/quality of life (QoL) score where a mean score of >1.0 means symptomatic pain, is employed at 2 weeks and at 1 year. Morbidities, narcotic usage, days to full activity and return to work, and CCS scores are reported. Sixty two patients, with 91 hernias repaired with self-gripping mesh, completed follow-up at a mean time period of 14.8 months. Seventeen hernias were direct defects (average size 3.0 cm). Mesh deployment time was 193.7 s. RR pain was 1.1/10 using a VAS. Total average oxycodone/acetaminophen (5 mg/325 mg) usage = 5.0 tablets, days to full activity was 1.6, and return to work was 4.2 days. Thirteen small asymptomatic seromas were palpated without any recurrences or groin tenderness, and all seromas resolved by the 6 month visit. Transient testis discomfort was reported in five patients. Urinary retention was 3.2%. Mean CCS™ scores at the first visit for groin pain laying, bending, sitting, walking, and step-climbing were 0.2, 0.5, 0.4, 0.3, and 0.3, respectively. At the first post op visit, 4.8% had symptomatic pain (CCS > 1). At 14.8 months, no patients reported symptomatic pain with CCS scores for all 62 patients averaging 0.02, (range 0-0.43). There are no recurrences thus far. Self-gripping mesh can be safely used during laparoscopic TEP inguinal hernia repairs; our cohort had a rapid recovery, and at the 1-year follow-up visit, there were no recurrences and no patients reported any chronic pain as defined by a CCS™ > 1.
Langer, Pierre; Black, Cameron; Egan, Padraig; Fitzpatrick, Noel
2018-06-22
To date, calvarial defects in dogs have traditionally been addressed with different types of implants including bone allograft, polymethylmethacrylate and titanium mesh secured with conventional metallic fixation methods. This report describes the use of an absorbable and non absorbable novel polymer fixation method, Bonewelding® technology, in combination with titanium mesh for the repair of calvarial defects in two dogs. The clinical outcomes and comparative complication using resorbable and non-resorbable thermoplastic pins were compared. This report of two cases documents the repair of a traumatic calvarial fracture in an adult male Greyhound and a cranioplasty following frontal bone tumor resection in an adult female Cavalier King Charles Spaniel with the use of a commercially available titanium mesh secured with an innovative thermoplastic polymer screw system (Bonewelding®). The treatment combination aimed to restore cranial structure, sinus integrity and cosmetic appearance. A mouldable titanium mesh was cut to fit the bone defect of the frontal bone and secured with either resorbable or non-resorbable polymer pins using Bonewelding® technology. Gentamycin-impregnated collagen sponge was used intraoperatively to assist with sealing of the frontal sinuses. Calvarial fracture and post-operative implant positioning were advised using computed tomography. A satisfactory restoration of skull integrity and cosmetic result was achieved, and long term clinical outcome was deemed clinically adequate with good patient quality of life. Postoperative complications including rostral mesh uplift with minor associated clinical signs were encountered when resorbable pins were used. No postoperative complications were experienced in non-resorbable pins at 7 months follow-up, by contrast mesh uplift was noted 3 weeks post-procedure in the case treated using absorbable pins. The report demonstrates the innovative use of sonic-activated polymer pins (Bonewelding® technology) alongside titanium mesh is a suitable alternative technique for skull defect repair in dogs. The use of Bonewelding® may offer advantages in reduction of surgical time. Further, ultrasonic pin application may be less invasive than alternative metallic fixation and potentially reduces bone trauma. Polymer systems may offer enhanced mesh-bone integration when compared to traditional metallic implants. The use of polymer pins demonstrates initial potential as a fixation method in cranioplasty. Initial findings in a single case comparison indicate a possible advantage in the use of non-absorbable over the absorbable systems to circumvent complications associated with variable polymer degradation, further long term studies with higher patient numbers are required before reliable conclusions can be made.
Retrofascial mesh repair of ventral incisional hernias.
Le, Hamilton; Bender, Jeffrey S
2005-03-01
Recurrence rates after ventral incisional hernia repair are reported to be as high as 33% and are associated with considerable morbidity and lost time. The purpose of this study was to determine if retrofascial mesh placement reduces the incidence of recurrence as well as the severity of wound infections. A prospective database covering the period from January 1995 to June 2003 was maintained. All patients underwent a standardized technique by a single surgeon. Polypropylene mesh was placed between the fascia and the peritoneum with the fascia closed over the mesh. There were 150 patients (126 women, 24 men) with a mean age of 55 years. Their average weight was 88 kg, with an average body mass index of 32. Sixty-three (42%) of the hernias were recurrences of a previous repair. The average size of the hernia was 8 x 14 cm. There was 1 postoperative mortality. There was a 9% postoperative infection rate with 2 patients (1%) requiring mesh removal. Long-term follow-up evaluation has revealed 3 recurrences (2%) and 3 readmissions for bowel obstruction with 1 patient requiring surgical release. There were no fistulas noted. Incisional hernia repair with mesh placed in the retrofascial position decreases both the risk for recurrence and the severity of wound infection without significant problems from bowel obstruction or enteric fistula.
Space-time VMS computation of wind-turbine rotor and tower aerodynamics
NASA Astrophysics Data System (ADS)
Takizawa, Kenji; Tezduyar, Tayfun E.; McIntyre, Spenser; Kostov, Nikolay; Kolesar, Ryan; Habluetzel, Casey
2014-01-01
We present the space-time variational multiscale (ST-VMS) computation of wind-turbine rotor and tower aerodynamics. The rotor geometry is that of the NREL 5MW offshore baseline wind turbine. We compute with a given wind speed and a specified rotor speed. The computation is challenging because of the large Reynolds numbers and rotating turbulent flows, and computing the correct torque requires an accurate and meticulous numerical approach. The presence of the tower increases the computational challenge because of the fast, rotational relative motion between the rotor and tower. The ST-VMS method is the residual-based VMS version of the Deforming-Spatial-Domain/Stabilized ST (DSD/SST) method, and is also called "DSD/SST-VMST" method (i.e., the version with the VMS turbulence model). In calculating the stabilization parameters embedded in the method, we are using a new element length definition for the diffusion-dominated limit. The DSD/SST method, which was introduced as a general-purpose moving-mesh method for computation of flows with moving interfaces, requires a mesh update method. Mesh update typically consists of moving the mesh for as long as possible and remeshing as needed. In the computations reported here, NURBS basis functions are used for the temporal representation of the rotor motion, enabling us to represent the circular paths associated with that motion exactly and specify a constant angular velocity corresponding to the invariant speeds along those paths. In addition, temporal NURBS basis functions are used in representation of the motion and deformation of the volume meshes computed and also in remeshing. We name this "ST/NURBS Mesh Update Method (STNMUM)." The STNMUM increases computational efficiency in terms of computer time and storage, and computational flexibility in terms of being able to change the time-step size of the computation. We use layers of thin elements near the blade surfaces, which undergo rigid-body motion with the rotor. We compare the results from computations with and without tower, and we also compare using NURBS and linear finite element basis functions in temporal representation of the mesh motion.
Space-Time VMS Computation of Wind-Turbine Rotor and Tower Aerodynamics
NASA Astrophysics Data System (ADS)
McIntyre, Spenser W.
This thesis is on the space{time variational multiscale (ST-VMS) computation of wind-turbine rotor and tower aerodynamics. The rotor geometry is that of the NREL 5MW offshore baseline wind turbine. We compute with a given wind speed and a specified rotor speed. The computation is challenging because of the large Reynolds numbers and rotating turbulent ows, and computing the correct torque requires an accurate and meticulous numerical approach. The presence of the tower increases the computational challenge because of the fast, rotational relative motion between the rotor and tower. The ST-VMS method is the residual-based VMS version of the Deforming-Spatial-Domain/Stabilized ST (DSD/SST) method, and is also called "DSD/SST-VMST" method (i.e., the version with the VMS turbulence model). In calculating the stabilization parameters embedded in the method, we are using a new element length definition for the diffusion-dominated limit. The DSD/SST method, which was introduced as a general-purpose moving-mesh method for computation of ows with moving interfaces, requires a mesh update method. Mesh update typically consists of moving the mesh for as long as possible and remeshing as needed. In the computations reported here, NURBS basis functions are used for the temporal representation of the rotor motion, enabling us to represent the circular paths associated with that motion exactly and specify a constant angular velocity corresponding to the invariant speeds along those paths. In addition, temporal NURBS basis functions are used in representation of the motion and deformation of the volume meshes computed and also in remeshing. We name this "ST/NURBS Mesh Update Method (STNMUM)." The STNMUM increases computational efficiency in terms of computer time and storage, and computational exibility in terms of being able to change the time-step size of the computation. We use layers of thin elements near the blade surfaces, which undergo rigid-body motion with the rotor. We compare the results from computations with and without tower, and we also compare using NURBS and linear finite element basis functions in temporal representation of the mesh motion.
Space-time mesh adaptation for solute transport in randomly heterogeneous porous media.
Dell'Oca, Aronne; Porta, Giovanni Michele; Guadagnini, Alberto; Riva, Monica
2018-05-01
We assess the impact of an anisotropic space and time grid adaptation technique on our ability to solve numerically solute transport in heterogeneous porous media. Heterogeneity is characterized in terms of the spatial distribution of hydraulic conductivity, whose natural logarithm, Y, is treated as a second-order stationary random process. We consider nonreactive transport of dissolved chemicals to be governed by an Advection Dispersion Equation at the continuum scale. The flow field, which provides the advective component of transport, is obtained through the numerical solution of Darcy's law. A suitable recovery-based error estimator is analyzed to guide the adaptive discretization. We investigate two diverse strategies guiding the (space-time) anisotropic mesh adaptation. These are respectively grounded on the definition of the guiding error estimator through the spatial gradients of: (i) the concentration field only; (ii) both concentration and velocity components. We test the approach for two-dimensional computational scenarios with moderate and high levels of heterogeneity, the latter being expressed in terms of the variance of Y. As quantities of interest, we key our analysis towards the time evolution of section-averaged and point-wise solute breakthrough curves, second centered spatial moment of concentration, and scalar dissipation rate. As a reference against which we test our results, we consider corresponding solutions associated with uniform space-time grids whose level of refinement is established through a detailed convergence study. We find a satisfactory comparison between results for the adaptive methodologies and such reference solutions, our adaptive technique being associated with a markedly reduced computational cost. Comparison of the two adaptive strategies tested suggests that: (i) defining the error estimator relying solely on concentration fields yields some advantages in grasping the key features of solute transport taking place within low velocity regions, where diffusion-dispersion mechanisms are dominant; and (ii) embedding the velocity field in the error estimator guiding strategy yields an improved characterization of the forward fringe of solute fronts which propagate through high velocity regions. Copyright © 2017 Elsevier B.V. All rights reserved.
Garcia-Cantero, Juan J; Brito, Juan P; Mata, Susana; Bayona, Sofia; Pastor, Luis
2017-01-01
Gaining a better understanding of the human brain continues to be one of the greatest challenges for science, largely because of the overwhelming complexity of the brain and the difficulty of analyzing the features and behavior of dense neural networks. Regarding analysis, 3D visualization has proven to be a useful tool for the evaluation of complex systems. However, the large number of neurons in non-trivial circuits, together with their intricate geometry, makes the visualization of a neuronal scenario an extremely challenging computational problem. Previous work in this area dealt with the generation of 3D polygonal meshes that approximated the cells' overall anatomy but did not attempt to deal with the extremely high storage and computational cost required to manage a complex scene. This paper presents NeuroTessMesh, a tool specifically designed to cope with many of the problems associated with the visualization of neural circuits that are comprised of large numbers of cells. In addition, this method facilitates the recovery and visualization of the 3D geometry of cells included in databases, such as NeuroMorpho, and provides the tools needed to approximate missing information such as the soma's morphology. This method takes as its only input the available compact, yet incomplete, morphological tracings of the cells as acquired by neuroscientists. It uses a multiresolution approach that combines an initial, coarse mesh generation with subsequent on-the-fly adaptive mesh refinement stages using tessellation shaders. For the coarse mesh generation, a novel approach, based on the Finite Element Method, allows approximation of the 3D shape of the soma from its incomplete description. Subsequently, the adaptive refinement process performed in the graphic card generates meshes that provide good visual quality geometries at a reasonable computational cost, both in terms of memory and rendering time. All the described techniques have been integrated into NeuroTessMesh, available to the scientific community, to generate, visualize, and save the adaptive resolution meshes.
Sentiment Analysis of Web Sites Related to Vaginal Mesh Use in Pelvic Reconstructive Surgery.
Hobson, Deslyn T G; Meriwether, Kate V; Francis, Sean L; Kinman, Casey L; Stewart, J Ryan
2018-05-02
The purpose of this study was to utilize sentiment analysis to describe online opinions toward vaginal mesh. We hypothesized that sentiment in legal Web sites would be more negative than that in medical and reference Web sites. We generated a list of relevant key words related to vaginal mesh and searched Web sites using the Google search engine. Each unique uniform resource locator (URL) was sorted into 1 of 6 categories: "medical", "legal", "news/media", "patient generated", "reference", or "unrelated". Sentiment of relevant Web sites, the primary outcome, was scored on a scale of -1 to +1, and mean sentiment was compared across all categories using 1-way analysis of variance. Tukey test evaluated differences between category pairs. Google searches of 464 unique key words resulted in 11,405 URLs. Sentiment analysis was performed on 8029 relevant URLs (3472 legal, 1625 "medical", 1774 "reference", 666 "news media", 492 "patient generated"). The mean sentiment for all relevant Web sites was +0.01 ± 0.16; analysis of variance revealed significant differences between categories (P < 0.001). Web sites categorized as "legal" and "news/media" had a slightly negative mean sentiment, whereas those categorized as "medical," "reference," and "patient generated" had slightly positive mean sentiments. Tukey test showed differences between all category pairs except the "medical" versus "reference" in comparison with the largest mean difference (-0.13) seen in the "legal" versus "reference" comparison. Web sites related to vaginal mesh have an overall mean neutral sentiment, and Web sites categorized as "medical," "reference," and "patient generated" have significantly higher sentiment scores than related Web sites in "legal" and "news/media" categories.
Mersilene mesh sling: short- and long-term clinical and urodynamic outcomes.
Young, S B; Howard, A E; Baker, S P
2001-07-01
We sought to determine the long-term efficacy, safety, and urodynamic effects of the Mersilene mesh suburethral sling in treating complicated forms of genuine stress incontinence. Two hundred women diagnosed with genuine stress incontinence, complicated by recurrence, intrinsic sphincter deficiency, or chronically increased intraabdominal pressure underwent a suburethral mesh sling procedure (Mersilene; Ethicon Inc, Somerville, NJ). They were monitored with yearly clinical examinations plus short- and long-term postoperative urodynamic evaluations; statistical analysis was carried out by use of the Friedman 2-way analysis by rank, Fischer-Freeman-Halton exact testing, analysis of variance for repeated measures, Wilcoxon, exact Mann-Whitney U test, and Bonferroni paired t test. Of 176 patients who were 5 months or more postop, 127 (72%) had preoperative and short-term postoperative urodynamic evaluations (range 5 to 23 months, mean 12.6 months). Fifty-two of 117 women who were more than 19 months postop (44%) completed preoperative and long-term postoperative urodynamic evaluations at a mean of 63 months (range 20 to 107). One hundred thirty-six of 176 patients (77%) who were more than 4 months postop had a short- and/or long- term postoperative urodynamic evaluation (range 5 to 107 months, mean 30 months). Objective cure rate by stress test was 93% (126 of 136 patients) at a mean of 30 months follow-up. The long-term objective cure rate was 94% (49 of 52). Subjectively, the short- and long-term cure rates were 95.3% and 90.4%, respectively. The cotton swab angle deflection decreased by a mean of 54 degrees at 1 year and 50 degrees at 5 years. Of the 10 failures, the mean preoperative cotton swab straining angle was 19.6 degrees, with 6 being < 30 degrees. Nineteen patients had a negative preoperative cotton swab angle test result (mean straining angle 15 degrees before operation, -6 degrees after operation) and a long-term cure rate of 67%. The objective cure rate in patients with positive cotton swab angle results monitored long term (mean 62 months) was 100% (41 of 41). The postvoid residual increased by a mean of 25 mL short term and 10 mL long term. Thirty-eight patients (19%) had a total of 43 complications. Seven patients (3.5%) had long-term retention. De novo detrusor instability occurred in 12 patients (8.8%), although it was cured in 6 (4.4%). Eight patients (4%) had vaginal or inguinal sling erosion and were healed after revision. Delayed healing at the vaginal sling site responded completely to estrogen cream in two (1%) patients. Five women had treatable vaginal stenosis, 5 had a local inguinal collection/infection unrelated to the mesh, and 3 required a 2-unit transfusion of packed red blood cells. One patient each had an entrapped nerve released, a cystotomy repaired, or experienced thigh numbness or groin pain. The suburethral Mersilene mesh sling has a very high long-term objective and subjective cure rate in the treatment of complicated forms of genuine stress incontinence. Frequent complications do occur but are remediable. The 33% failure rate among patients with a preoperative negative cotton swab angle test result and the very low cotton swab straining angle among the 7% who had sling failures further confirms the widely held belief that sling urethropexy in the absence of hypermobility lacks efficacy.
Load Sharing Behavior of Star Gearing Reducer for Geared Turbofan Engine
NASA Astrophysics Data System (ADS)
Mo, Shuai; Zhang, Yidu; Wu, Qiong; Wang, Feiming; Matsumura, Shigeki; Houjoh, Haruo
2017-07-01
Load sharing behavior is very important for power-split gearing system, star gearing reducer as a new type and special transmission system can be used in many industry fields. However, there is few literature regarding the key multiple-split load sharing issue in main gearbox used in new type geared turbofan engine. Further mechanism analysis are made on load sharing behavior among star gears of star gearing reducer for geared turbofan engine. Comprehensive meshing error analysis are conducted on eccentricity error, gear thickness error, base pitch error, assembly error, and bearing error of star gearing reducer respectively. Floating meshing error resulting from meshing clearance variation caused by the simultaneous floating of sun gear and annular gear are taken into account. A refined mathematical model for load sharing coefficient calculation is established in consideration of different meshing stiffness and supporting stiffness for components. The regular curves of load sharing coefficient under the influence of interactions, single action and single variation of various component errors are obtained. The accurate sensitivity of load sharing coefficient toward different errors is mastered. The load sharing coefficient of star gearing reducer is 1.033 and the maximum meshing force in gear tooth is about 3010 N. This paper provides scientific theory evidences for optimal parameter design and proper tolerance distribution in advanced development and manufacturing process, so as to achieve optimal effects in economy and technology.
NASA Technical Reports Server (NTRS)
Zhang, Zeng-Chan; Yu, S. T. John; Chang, Sin-Chung; Jorgenson, Philip (Technical Monitor)
2001-01-01
In this paper, we report a version of the Space-Time Conservation Element and Solution Element (CE/SE) Method in which the 2D and 3D unsteady Euler equations are simulated using structured or unstructured quadrilateral and hexahedral meshes, respectively. In the present method, mesh values of flow variables and their spatial derivatives are treated as independent unknowns to be solved for. At each mesh point, the value of a flow variable is obtained by imposing a flux conservation condition. On the other hand, the spatial derivatives are evaluated using a finite-difference/weighted-average procedure. Note that the present extension retains many key advantages of the original CE/SE method which uses triangular and tetrahedral meshes, respectively, for its 2D and 3D applications. These advantages include efficient parallel computing ease of implementing non-reflecting boundary conditions, high-fidelity resolution of shocks and waves, and a genuinely multidimensional formulation without using a dimensional-splitting approach. In particular, because Riemann solvers, the cornerstones of the Godunov-type upwind schemes, are not needed to capture shocks, the computational logic of the present method is considerably simpler. To demonstrate the capability of the present method, numerical results are presented for several benchmark problems including oblique shock reflection, supersonic flow over a wedge, and a 3D detonation flow.
NASA Technical Reports Server (NTRS)
Njoku, E.; Wilson, W.; Yueh, S.; Freeland, R.; Helms, R.; Edelstein, W.; Sadowy, G.; Farra, D.; West, R.; Oxnevad, K.
2001-01-01
This report describes a two-year study of a large-aperture, lightweight, deployable mesh antenna system for radiometer and radar remote sensing of the Earth from space. The study focused specifically on an instrument to measure ocean salinity and Soil moisture. Measurements of ocean salinity and soil moisture are of critical . importance in improving knowledge and prediction of key ocean and land surface processes, but are not currently obtainable from space. A mission using this instrument would be the first demonstration of deployable mesh antenna technology for remote sensing and could lead to potential applications in other remote sensing disciplines that require high spatial resolution measurements. The study concept features a rotating 6-m-diameter deployable mesh antenna, with radiometer and radar sensors, to measure microwave emission and backscatter from the Earth's surface. The sensors operate at L and S bands, with multiple polarizations and a constant look angle, scanning across a wide swath. The study included detailed analyses of science requirements, reflector and feedhorn design and performance, microwave emissivity measurements of mesh samples, design and test of lightweight radar electronic., launch vehicle accommodations, rotational dynamics simulations, and an analysis of attitude control issues associated with the antenna and spacecraft, The goal of the study was to advance the technology readiness of the overall concept to a level appropriate for an Earth science emission.
Field and long-term demonstration of a wide area quantum key distribution network.
Wang, Shuang; Chen, Wei; Yin, Zhen-Qiang; Li, Hong-Wei; He, De-Yong; Li, Yu-Hu; Zhou, Zheng; Song, Xiao-Tian; Li, Fang-Yi; Wang, Dong; Chen, Hua; Han, Yun-Guang; Huang, Jing-Zheng; Guo, Jun-Fu; Hao, Peng-Lei; Li, Mo; Zhang, Chun-Mei; Liu, Dong; Liang, Wen-Ye; Miao, Chun-Hua; Wu, Ping; Guo, Guang-Can; Han, Zheng-Fu
2014-09-08
A wide area quantum key distribution (QKD) network deployed on communication infrastructures provided by China Mobile Ltd. is demonstrated. Three cities and two metropolitan area QKD networks were linked up to form the Hefei-Chaohu-Wuhu wide area QKD network with over 150 kilometers coverage area, in which Hefei metropolitan area QKD network was a typical full-mesh core network to offer all-to-all interconnections, and Wuhu metropolitan area QKD network was a representative quantum access network with point-to-multipoint configuration. The whole wide area QKD network ran for more than 5000 hours, from 21 December 2011 to 19 July 2012, and part of the network stopped until last December. To adapt to the complex and volatile field environment, the Faraday-Michelson QKD system with several stability measures was adopted when we designed QKD devices. Through standardized design of QKD devices, resolution of symmetry problem of QKD devices, and seamless switching in dynamic QKD network, we realized the effective integration between point-to-point QKD techniques and networking schemes.
A Novel Coarsening Method for Scalable and Efficient Mesh Generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoo, A; Hysom, D; Gunney, B
2010-12-02
In this paper, we propose a novel mesh coarsening method called brick coarsening method. The proposed method can be used in conjunction with any graph partitioners and scales to very large meshes. This method reduces problem space by decomposing the original mesh into fixed-size blocks of nodes called bricks, layered in a similar way to conventional brick laying, and then assigning each node of the original mesh to appropriate brick. Our experiments indicate that the proposed method scales to very large meshes while allowing simple RCB partitioner to produce higher-quality partitions with significantly less edge cuts. Our results further indicatemore » that the proposed brick-coarsening method allows more complicated partitioners like PT-Scotch to scale to very large problem size while still maintaining good partitioning performance with relatively good edge-cut metric. Graph partitioning is an important problem that has many scientific and engineering applications in such areas as VLSI design, scientific computing, and resource management. Given a graph G = (V,E), where V is the set of vertices and E is the set of edges, (k-way) graph partitioning problem is to partition the vertices of the graph (V) into k disjoint groups such that each group contains roughly equal number of vertices and the number of edges connecting vertices in different groups is minimized. Graph partitioning plays a key role in large scientific computing, especially in mesh-based computations, as it is used as a tool to minimize the volume of communication and to ensure well-balanced load across computing nodes. The impact of graph partitioning on the reduction of communication can be easily seen, for example, in different iterative methods to solve a sparse system of linear equation. Here, a graph partitioning technique is applied to the matrix, which is basically a graph in which each edge is a non-zero entry in the matrix, to allocate groups of vertices to processors in such a way that many of matrix-vector multiplication can be performed locally on each processor and hence to minimize communication. Furthermore, a good graph partitioning scheme ensures the equal amount of computation performed on each processor. Graph partitioning is a well known NP-complete problem, and thus the most commonly used graph partitioning algorithms employ some forms of heuristics. These algorithms vary in terms of their complexity, partition generation time, and the quality of partitions, and they tend to trade off these factors. A significant challenge we are currently facing at the Lawrence Livermore National Laboratory is how to partition very large meshes on massive-size distributed memory machines like IBM BlueGene/P, where scalability becomes a big issue. For example, we have found that the ParMetis, a very popular graph partitioning tool, can only scale to 16K processors. An ideal graph partitioning method on such an environment should be fast and scale to very large meshes, while producing high quality partitions. This is an extremely challenging task, as to scale to that level, the partitioning algorithm should be simple and be able to produce partitions that minimize inter-processor communications and balance the load imposed on the processors. Our goals in this work are two-fold: (1) To develop a new scalable graph partitioning method with good load balancing and communication reduction capability. (2) To study the performance of the proposed partitioning method on very large parallel machines using actual data sets and compare the performance to that of existing methods. The proposed method achieves the desired scalability by reducing the mesh size. For this, it coarsens an input mesh into a smaller size mesh by coalescing the vertices and edges of the original mesh into a set of mega-vertices and mega-edges. A new coarsening method called brick algorithm is developed in this research. In the brick algorithm, the zones in a given mesh are first grouped into fixed size blocks called bricks. These brick are then laid in a way similar to conventional brick laying technique, which reduces the number of neighboring blocks each block needs to communicate. Contributions of this research are as follows: (1) We have developed a novel method that scales to a really large problem size while producing high quality mesh partitions; (2) We measured the performance and scalability of the proposed method on a machine of massive size using a set of actual large complex data sets, where we have scaled to a mesh with 110 million zones using our method. To the best of our knowledge, this is the largest complex mesh that a partitioning method is successfully applied to; and (3) We have shown that proposed method can reduce the number of edge cuts by as much as 65%.« less
Isemer, Friedrich-Eckart; Dietz, Ulrich; Ackermann, Maximilian
2018-05-18
Surgical approaches to flank hernias have been poorly standardised. The most demanding issues in intermuscular net insertion are the limited area in the dorsal direction and the difficulties in fixing the net to the costal arch or the iliac crest. This is why many different surgical procedures have been published. From August 2015 to October 2016, nine patients with a primary incisional lateral hernia received open retromuscular preperitoneal mesh repair. In intermuscular mesh placement, the mesh size must be smaller at smaller values of the CPA (costopelvic angle). On the dorsal side of the reference stretch RS of 10 cm between costal arch and iliac crest, fixations are necessary to achieve stability. Retroperitoneal preperitoneal net implantation is unrestricted by the patient's anatomy. The placement of the mesh is similar to the Stoppa procedure and almost any size can be used with little fixation. Remodeling of the abdominal wall can be comfortably achieved. All 9 patients underwent retromuscular preperitoneal mesh repair. The hernia size was 92.85 cm 2 with a corresponding mesh size of 426.22 cm 2 . No adverse side effects or surgical complications were observed; the length of hospital stay was between 3 to 7 days; the follow up was 3 to 18 months, with a mean follow-up of 9.1 months. In a follow-up questionnaire, the patients reported a high satisfaction rate with a grade of 1,2 (school mark); there was no recurrence. The pain level decreased from VAS grade 4 preoperatively to 1.2 postoperatively. 7 patients had no pain at all. In conclusion, adequate overlap of the implanted mesh can be achieved in the preperitoneal retromuscular space even in large hernias. Fixation of the mesh to the costal arch or the iliac crest is not necessary and would only induce postoperative pain. Long-term stability depends on the size of the mesh. Remodeling of the abdominal wall with closure of the fascia above the mesh can be easily achieved. Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
DiPietro, Kelsey L.; Lindsay, Alan E.
2017-11-01
We present an efficient moving mesh method for the simulation of fourth order nonlinear partial differential equations (PDEs) in two dimensions using the Parabolic Monge-Ampére (PMA) equation. PMA methods have been successfully applied to the simulation of second order problems, but not on systems with higher order equations which arise in many topical applications. Our main application is the resolution of fine scale behavior in PDEs describing elastic-electrostatic interactions. The PDE system considered has multiple parameter dependent singular solution modalities, including finite time singularities and sharp interface dynamics. We describe how to construct a dynamic mesh algorithm for such problems which incorporates known self similar or boundary layer scalings of the underlying equation to locate and dynamically resolve fine scale solution features in these singular regimes. We find a key step in using the PMA equation for mesh generation in fourth order problems is the adoption of a high order representation of the transformation from the computational to physical mesh. We demonstrate the efficacy of the new method on a variety of examples and establish several new results and conjectures on the nature of self-similar singularity formation in higher order PDEs.
Sarli, L; Iusco, D R; Sansebastiano, G; Costi, R
2001-08-01
No randomized trial exists that specifically addresses the issue of laparoscopic bilateral inguinal hernia repair. The purpose of the present prospective, randomized, controlled, clinical study was to assess short- and long-term results when comparing simultaneous bilateral hernia repair by an open, tension-free anterior approach with laparoscopic "bikini mesh" posterior repair. Forty-three low-risk male patients with bilateral primary inguinal hernia were randomly assigned to undergo either laparoscopic preperitoneal "bikini mesh" hernia repair (TAPP) or open Lichtenstein hernioplasty. There was no difference in operating time between the two groups. The mean cost of laparoscopic hernioplasty was higher (P < 0.001). The intensity of postoperative pain was greater in the open hernia repair group at 24 hours, 48 hours, and 7 days after surgery (P < 0.001), with a greater consumption of pain medication among these patients (P < 0.05). The median time to return to work was 30 days for the open hernia repair group and 16 days for the laparoscopic "bikini mesh" repair group (P < 0.05). Only 1 asymptomatic recurrence (4.3%) was discovered in the open group. The laparoscopic approach to bilateral hernia with "bikini mesh" appears to be preferable to the open Lichtenstein tension-free hernioplasty in terms of the postoperative quality of life and interruption of occupational activity.
The procedure of mesh wrapping the gastric pouch in cadaver study.
Gong, Ke; Gagner, Michel; Bardaro, Sergio; Ueda, Kazuki
2007-12-01
Dietary and behavioral modifications have resulted in limited long-term success in curing morbidly obese patients, and surgery remains the only effective treatment. Of the surgical procedures that are the most commonly offered, Roux-en-Y gastric bypass (RYGB) appears to offer the best long-term results. However 5-15% of patients will not achieve successful weight loss after RYGB. There are many reports showing that the patients who underwent gastric bypass surgeries regain weight over time. The cause for this remains unclear. Several factors may contribute, including dilation of the gastric pouch and the gastrojejunal anastomosis. However, the data to support the link is sparse. The objective of this paper is to describe the surgical technique of wrapping the gastric pouch with a polytetrafluoroethylene (PTFE) mesh to prevent gastric pouch dilatation. In specific, we created a 20-30 ml gastric pouch and subsequently, the gastrojejunostomy was performed with a circular stapler. Afterwards, the mesentery was dissected and the gastric pouch was wrapped with the PTFE mesh. We have performed this procedure on three cadavers with an average operative time of 75 minutes. We found that the procedure of wrapping the gastric pouch was not particularly difficult. As a result, the gastric pouch, gastrojejunal anastomosis and the stump of the jejunum are all totally wrapped within the mesh. It may be effective in the prevention of dilatation.
The drug treatment of delayed ejaculation
Elsaied, Moustafa A.; Mostafa, Taymour
2016-01-01
Delayed ejaculation (DE) is an uncommon and a challenging disorder to treat. It is often quite concerning to patients and it can affect psychosocial well-being. Here we reviewed how DE is treated pharmacologically .We also highlighted specific settings where drugs could be introduced to medical practice. Electronic databases were searched from 1966 to February 2016, including PubMed MEDLINE, EMBASE, EBCSO Academic Search Complete, Cochrane Systematic Reviews Database, and Google Scholar using key words; delayed ejaculation, retarded ejaculation, inhibited ejaculation, drugs, treatment, or pharmacology. To achieve the maximum sensitivity of the search strategy and to identify all studies, we combined “delayed ejaculation” as Medical Subject Headings (MeSH) terms or keywords with each of “testosterone” or “cabergoline” or “bupropion” or “amantadine” or “cyproheptadine” or “midodrine” or “imipramine” or “ephedrine” or “pseudoephedrine” or “yohimbine” or “buspirone” or “oxytocin” or “bethanechol” as MeSH terms or keywords. There are a number of drugs to treat patients with DE including: testosterone, cabergoline, bupropion, amantadine, cyproheptadine, midodrine, imipramine, ephedrine, pseudoephedrine, yohimbine, buspirone, oxytocin, and bethanechol. Although there are many pharmacological treatment options, the evidence is still limited to small trials, case series or case reports. Review of literature showed that evidence level 1 (Double blind randomized clinical trial) studies were performed with testosterone, oxytocin, buspirone or bethanechol treatment. It is concluded that successful drug treatment of DE is still in its infancy. The clinicians need to be aware of the pathogenesis of DE and the pharmacological basis underlying the use of different drugs to extend better care for these patients. Various drugs are available to address such problem, however their evidence of efficacy is still limited and their choice needs to be individualized to each specific case. PMID:27652229
Element Verification and Comparison in Sierra/Solid Mechanics Problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohashi, Yuki; Roth, William
2016-05-01
The goal of this project was to study the effects of element selection on the Sierra/SM solutions to five common solid mechanics problems. A total of nine element formulations were used for each problem. The models were run multiple times with varying spatial and temporal discretization in order to ensure convergence. The first four problems have been compared to analytical solutions, and all numerical results were found to be sufficiently accurate. The penetration problem was found to have a high mesh dependence in terms of element type, mesh discretization, and meshing scheme. Also, the time to solution is shown formore » each problem in order to facilitate element selection when computer resources are limited.« less
NASA Technical Reports Server (NTRS)
Sorenson, R. L.
1980-01-01
A method for generating two dimensional finite difference grids about airfoils and other shapes by the use of the Poisson differential equation is developed. The inhomogeneous terms are automatically chosen such that two important effects are imposed on the grid at both the inner and outer boundaries. The first effect is control of the spacing between mesh points along mesh lines intersecting the boundaries. The second effect is control of the angles with which mesh lines intersect the boundaries. A FORTRAN computer program has been written to use this method. A description of the program, a discussion of the control parameters, and a set of sample cases are included.
Choi, Judy M; Nguyen, Vian; Khavari, Rose; Reeves, Keith; Snyder, Michael; Fletcher, Sophie G
2012-01-01
The use of synthetic mesh for transvaginal pelvic organ prolapse (POP) repair is associated with the rare complication of mesh erosion into hollow viscera. This study presents a single-institution series of complex rectovaginal fistulas (RVFs) after synthetic mesh-augmented POP repair, as well as strategies for identification and management. Institutional review board approval was obtained for this retrospective study. Data were collected and analyzed on all female patients undergoing RVF repair from 2000 to 2011 at our institution. Thirty-seven patients underwent RVF repair at our multidisciplinary center for restorative pelvic medicine. Of these, 10 (27.0%) were associated with POP repairs using mesh. The POP repairs resulting in RVF were transvaginal repair with mesh (n = 8), laparoscopic sacrocolpopexy with concomitant traditional posterior repair (n = 1), and robotic-assisted laparoscopic sacrocolpopexy (n = 1). Time to presentation was an average of 7.1 months after POP repair. Patients underwent a mean of 4.4 surgeries for definitive RVF repair, with 40% of patients requiring a bowel diversion (3 temporary ileostomies and 1 long-term colostomy). Mean follow-up time after last surgery was 9.2 months. On follow-up, 1 patient has a persistent fistula with vaginal mesh extrusion. One patient has persistent pelvic pain. This series highlights the significant impact of synthetic mesh complications in the posterior compartment. These complications should be cautionary for synthetic graft use by those with limited experience, particularly when an alternate choice of traditional repair is available. When symptoms of RVF are present, collaboration with a colon and rectal specialist should be initiated as soon as possible for evaluation and definitive repair.
Motiee-Langroudi, Maziar; Harirchi, Iraj; Amali, Amin; Jafari, Mehrdad
2015-12-01
To describe the authors' experience in the reconstruction of patients after total maxillectomy with preservation of orbital contents for maxillary tumors using titanium mesh and autogenous fascia lata, where no setting for free flap reconstruction is available. Twelve consecutive patients with paranasal sinus tumors underwent total maxillectomy without orbital exenterations and primary reconstruction. The defects were reconstructed by titanium mesh in combination with autogenous fascia lata in the orbital floor performed by 1 surgical team. Titanium mesh (0.2 mm thick) was contoured and fixed to reconstruct the orbital floor and obtain midface projection. Fascia lata was used to cover the titanium mesh along the orbital floor to prevent fat entrapment in the mesh holes. The most common pathology was squamous cell carcinoma (50%). Patients' mean age was 45.66 years (33 to 74 yr). The mean follow-up period was 35.2 months (30 to 49 months). During follow-up, no infection or foreign body reaction was encountered. Extrusion of titanium mesh occurred in 4 patients who underwent postoperative radiotherapy. Two cases of mild diplopia at extreme gaze occurred early during the postoperative period that resolved after a few months. Placing fascia lata between the titanium mesh surface of the orbital implant and the orbital contents was successful in preventing long-term diplopia or dystopia. Nevertheless, exposure of the titanium implant through the skin surface represented a complication of this technique in 25% of patients. Further studies are required with head-to-head comparisons of artificial materials and free flaps for reconstruction of maxillectomy defects. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Glazener, Cathryn Ma; Breeman, Suzanne; Elders, Andrew; Hemming, Christine; Cooper, Kevin G; Freeman, Robert M; Smith, Anthony Rb; Reid, Fiona; Hagen, Suzanne; Montgomery, Isobel; Kilonzo, Mary; Boyers, Dwayne; McDonald, Alison; McPherson, Gladys; MacLennan, Graeme; Norrie, John
2017-01-28
The use of transvaginal mesh and biological graft material in prolapse surgery is controversial and has led to a number of enquiries into their safety and efficacy. Existing trials of these augmentations are individually too small to be conclusive. We aimed to compare the outcomes of prolapse repair involving either synthetic mesh inlays or biological grafts against standard repair in women. We did two pragmatic, parallel-group, multicentre, randomised controlled trials for our study (PROSPECT [PROlapse Surgery: Pragmatic Evaluation and randomised Controlled Trials]) in 35 centres (a mix of secondary and tertiary referral hospitals) in the UK. We recruited women undergoing primary transvaginal anterior or posterior compartment prolapse surgery by 65 gynaecological surgeons in these centres. We randomly assigned participants by a remote web-based randomisation system to one of the two trials: comparing standard (native tissue) repair alone with standard repair augmented with either synthetic mesh (the mesh trial) or biological graft (the graft trial). We assigned women (1:1:1 or 1:1) within three strata: assigned to one of the three treatment options, comparison of standard repair with mesh, and comparison of standard repair with graft. Participants, ward staff, and outcome assessors were masked to randomisation where possible; masking was obviously not possible for the surgeon. Follow-up was for 2 years after the surgery; the primary outcomes, measured at 1 year and 2 years, were participant-reported prolapse symptoms (i.e. the Pelvic Organ Prolapse Symptom Score [POP-SS]) and condition-specific (ie, prolapse-related) quality-of-life scores, analysed in the modified intention-to-treat population. This trial is registered as an International Standard Randomised Controlled Trial, number ISRCTN60695184. Between Jan 8, 2010, and Aug 30, 2013, we randomly allocated 1352 women to treatment, of whom 1348 were included in the analysis. 865 women were included in the mesh trial (430 to standard repair alone, 435 to mesh augmentation) and 735 were included in the graft trial (367 to standard repair alone, 368 to graft augmentation). Because the analyses were carried out separately for each trial (mesh trial and graft trial) some women in the standard repair arm assigned to all treatment options were included in the standard repair group of both trials. 23 of these women did not receive any surgery (15 in the mesh trial, 13 in the graft trial; five were included in both trials) and were included in the baseline analyses only. Mean POP-SS at 1 year did not differ substantially between comparisons (standard 5·4 [SD 5·5] vs mesh 5·5 [5·1], mean difference 0·00, 95% CI -0·70 to 0·71; p=0·99; standard 5·5 [SD 5·6] vs graft 5·6 [5·6]; mean difference -0·15, -0·93 to 0·63; p=0·71). Mean prolapse-related quality-of-life scores also did not differ between groups at 1 year (standard 2·0 [SD 2·7] vs mesh 2·2 [2·7], mean difference 0·13, 95% CI -0·25 to 0·51; p=0·50; standard 2·2 [SD 2·8] vs graft 2·4 [2·9]; mean difference 0·13, -0·30 to 0·56; p=0·54). Mean POP-SS at 2 years were: standard 4·9 (SD 5·1) versus mesh 5·3 (5·1), mean difference 0·32, 95% CI -0·39 to 1·03; p=0·37; standard 4·9 (SD 5·1) versus graft 5·5 (5·7); mean difference 0·32, -0·48 to 1·12; p=0·43. Prolapse-related quality-of-life scores at 2 years were: standard 1·9 (SD 2·5) versus mesh 2·2 (2·6), mean difference 0·15, 95% CI -0·23 to 0·54; p=0·44; standard 2·0 (2·5) versus graft 2·2 (2·8); mean difference 0·10, -0·33 to 0·52; p=0·66. Serious adverse events such as infection, urinary retention, or dyspareunia or other pain, excluding mesh complications, occurred with similar frequency in the groups over 1 year (mesh trial: 31/430 [7%] with standard repair vs 34/435 [8%] with mesh, risk ratio [RR] 1·08, 95% CI 0·68 to 1·72; p=0·73; graft trial: 23/367 [6%] with standard repair vs 36/368 [10%] with graft, RR 1·57, 0·95 to 2·59; p=0·08). The cumulative number of women with a mesh complication over 2 years in women actually exposed to synthetic mesh was 51 (12%) of 434. Augmentation of a vaginal repair with mesh or graft material did not improve women's outcomes in terms of effectiveness, quality of life, adverse effects, or any other outcome in the short term, but more than one in ten women had a mesh complication. Therefore, follow-up is vital to identify any longer-term potential benefits and serious adverse effects of mesh or graft reinforcement in vaginal prolapse surgery. UK National Institute of Health Research. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
Towards a more molecular taxonomy of disease.
Park, Jisoo; Hescott, Benjamin J; Slonim, Donna K
2017-07-27
Disease taxonomies have been designed for many applications, but they tend not to fully incorporate the growing amount of molecular-level knowledge of disease processes, inhibiting research efforts. Understanding the degree to which we can infer disease relationships from molecular data alone may yield insights into how to ultimately construct more modern taxonomies that integrate both physiological and molecular information. We introduce a new technique we call Parent Promotion to infer hierarchical relationships between disease terms using disease-gene data. We compare this technique with both an established ontology inference method (CliXO) and a minimum weight spanning tree approach. Because there is no gold standard molecular disease taxonomy available, we compare our inferred hierarchies to both the Medical Subject Headings (MeSH) category C forest of diseases and to subnetworks of the Disease Ontology (DO). This comparison provides insights about the inference algorithms, choices of evaluation metrics, and the existing molecular content of various subnetworks of MeSH and the DO. Our results suggest that the Parent Promotion method performs well in most cases. Performance across MeSH trees is also correlated between inference methods. Specifically, inferred relationships are more consistent with those in smaller MeSH disease trees than larger ones, but there are some notable exceptions that may correlate with higher molecular content in MeSH. Our experiments provide insights about learning relationships between diseases from disease genes alone. Future work should explore the prospect of disease term discovery from molecular data and how best to integrate molecular data with anatomical and clinical knowledge. This study nonetheless suggests that disease gene information has the potential to form an important part of the foundation for future representations of the disease landscape.
Emanuelsson, P; Gunnarsson, U; Strigård, K; Stark, B
2014-08-01
The aim of this study was to evaluate early complications following retromuscular mesh repair with those after dual layer suture of the anterior rectus sheath in a randomised controlled clinical trial for abdominal rectus muscle diastasis (ARD). Patients with an ARD wider than 3 cm and clinical symptoms related to the ARD were included in a prospective randomised study. They were assigned to either retromuscular inset of a lightweight polypropylene mesh or to dual closure of the anterior rectus fascia using Quill self-locking technology. All patients completed a validated questionnaire for pain assessment (Ventral Hernia Pain Questionnaire, VHPQ) and for quality of life (SF36) prior to and 3 months after surgery. The most frequently seen adverse event was minor wound infection. Of the patients, 14/57 had a superficial wound infection; five related to Quill and nine to mesh repair. No deep wound infections were reported. Patient rating for subjective muscular improvement postoperatively was better in the mesh technique group with a mean of 6.9 (range 0-10) compared to a mean of 4.8 (range 0-10) in the Quill group (p=0.01). The pre- and post-operative SF36 scores improved in both groups. There was no significant difference between the two surgical techniques in terms of early complications and perceived pain at the 3-month follow-up. Both techniques may be considered equally reliable for ARD repair in terms of adverse outcomes during the early postoperative phase, even though patients operated with a mesh experienced better improvement in muscular strength. ClinicalTrial.gov: 2009/227-31/3/PE/96. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Stirler, Vincent M A; Raymakers, Johan T F J; Rakic, Srdjan
2016-07-01
The aim of the study was to introduce a new surgical treatment for anterior cutaneous nerve entrapment syndrome, a frequently unrecognised disorder in the general population responsible for chronic abdominal wall pain with limited treatment options to date. We hypothesised that intraperitoneal onlay mesh reinforcement could dissipate excessive increases in intra-abdominal pressure and prevent entrapment of the neurovascular bundle. Retrospective cohort analysis was performed between September 2002 and March 2014. All consecutive patients diagnosed with anterior cutaneous nerve entrapment syndrome refractory to conservative treatment (n = 30) underwent laparoscopic intraperitoneal onlay mesh reinforcement of the painful area in the abdominal wall. Planned follow-up took place at 2, 6 and 12 weeks after surgery and at time of analysis (March 2015). Primary outcome was patients' satisfaction after treatment at short and long term (last follow-up) using a verbal rating score as measurement (1 = I am very satisfied; I never experience pain, 2 = I am satisfied; I occasionally experience some pain, 3 = I have improved but experience pain on a regular basis, 4 = I have had no result on this treatment, 5 = my pain is worse after treatment). Scores 1 and 2 were classified as success, and scores 4 and 5 as failure of the treatment. Thirty patients underwent laparoscopic intraperitoneal onlay mesh reinforcement. None were lost to follow-up (mean 54 ± 44 months, range 12-122, median 38). Short- and long-term success rates were 90 and 71 %, respectfully. Intraperitoneal onlay mesh reinforcement of the abdominal wall seems to be a promising option for the treatment of intractable anterior cutaneous nerve entrapment syndrome.
Mapping the Structure and Dynamics of Genomics-Related MeSH Terms Complex Networks
Siqueiros-García, Jesús M.; Hernández-Lemus, Enrique; García-Herrera, Rodrigo; Robina-Galatas, Andrea
2014-01-01
It has been proposed that the history and evolution of scientific ideas may reflect certain aspects of the underlying socio-cognitive frameworks in which science itself is developing. Systematic analyses of the development of scientific knowledge may help us to construct models of the collective dynamics of science. Aiming at scientific rigor, these models should be built upon solid empirical evidence, analyzed with formal tools leading to ever-improving results that support the related conclusions. Along these lines we studied the dynamics and structure of the development of research in genomics as represented by the entire collection of genomics-related scientific papers contained in the PubMed database. The analyzed corpus consisted in more than 49,000 articles published in the years 1987 (first appeareance of the term Genomics) to 2011, categorized by means of the Medical Subheadings (MeSH) content-descriptors. Complex networks were built where two MeSH terms were connected if they are descriptors of the same article(s). The analysis of such networks revealed a complex structure and dynamics that to certain extent resembled small-world networks. The evolution of such networks in time reflected interesting phenomena in the historical development of genomic research, including what seems to be a phase-transition in a period marked by the completion of the first draft of the Human Genome Project. We also found that different disciplinary areas have different dynamic evolution patterns in their MeSH connectivity networks. In the case of areas related to science, changes in topology were somewhat fast while retaining a certain core-stucture, whereas in the humanities, the evolution was pretty slow and the structure resulted highly redundant and in the case of technology related issues, the evolution was very fast and the structure remained tree-like with almost no overlapping terms. PMID:24699262
An Immersed Boundary-Lattice Boltzmann Method for Simulating Particulate Flows
NASA Astrophysics Data System (ADS)
Zhang, Baili; Cheng, Ming; Lou, Jing
2013-11-01
A two-dimensional momentum exchange-based immersed boundary-lattice Boltzmann method developed by X.D. Niu et al. (2006) has been extended in three-dimensions for solving fluid-particles interaction problems. This method combines the most desirable features of the lattice Boltzmann method and the immersed boundary method by using a regular Eulerian mesh for the flow domain and a Lagrangian mesh for the moving particles in the flow field. The non-slip boundary conditions for the fluid and the particles are enforced by adding a force density term into the lattice Boltzmann equation, and the forcing term is simply calculated by the momentum exchange of the boundary particle density distribution functions, which are interpolated by the Lagrangian polynomials from the underlying Eulerian mesh. This method preserves the advantages of lattice Boltzmann method in tracking a group of particles and, at the same time, provides an alternative approach to treat solid-fluid boundary conditions. Numerical validations show that the present method is very accurate and efficient. The present method will be further developed to simulate more complex problems with particle deformation, particle-bubble and particle-droplet interactions.
How to improve your PubMed/MEDLINE searches: 3. advanced searching, MeSH and My NCBI.
Fatehi, Farhad; Gray, Leonard C; Wootton, Richard
2014-03-01
Although the basic PubMed search is often helpful, the results may sometimes be non-specific. For more control over the search process you can use the Advanced Search Builder interface. This allows a targeted search in specific fields, with the convenience of being able to select the intended search field from a list. It also provides a history of your previous searches. The search history is useful to develop a complex search query by combining several previous searches using Boolean operators. For indexing the articles in MEDLINE, the NLM uses a controlled vocabulary system called MeSH. This standardised vocabulary solves the problem of authors, researchers and librarians who may use different terms for the same concept. To be efficient in a PubMed search, you should start by identifying the most appropriate MeSH terms and use them in your search where possible. My NCBI is a personal workspace facility available through PubMed and makes it possible to customise the PubMed interface. It provides various capabilities that can enhance your search performance.
Boukerrou, M; Just, S Bresson; Girard, J-M; Nayama, M; Cosson, M
2008-02-01
The purpose of the study was to compare a polyester mesh coated with silicone (LIFT, Cousin) to a polypropylene mesh (TVT, Gynecare), in terms of results, and short and middle term complications. We have performed a retrospective study concerning 140 patients between 2000 and 2002 (71 LIFT and 69 TVT operated for stress incontinence with or without vaginal surgery (prolapse surgery or hysterectomy). We noticed per- and postoperative complications. The patients were contacted by phone to evaluate the middle and long-term results. The mean age of the patients were of 58.8+/-11.3 years in LIFT group and 57.2+/-7.5 years in TVT group. More intraoperative complications arose in the TVT group (six bladder injuries and three haemorrhages versus two in LIFT group, p<0.05). There was no difference for the postoperative time. The mean follow-up was 16.6+/-5.7 months for the LIFT and 32.2+/-11.3 months for the TVT. 80% of the patients were dry in the LIFT and 75.8% in the TVT group. There was no significant difference concerning the rate of de novo urge incontinence (18.3 versus 17.7%) and voiding difficulties (10 versus 16%). On the other hand, 6.7% of the patients of the group LIFT presented bad healing with prosthesis exposure, in every case a partial resection of the mesh was performed. We did not observe any case of exposure in the TVT group. The LIFT seems as effective as the TVT with a rate of de novo urge incontinence and voiding difficulties similar to the TVT and to the literature's data. However the rate of 6.7% of exposure leads us to prefer polypropylene meshes.
Criss, Cory N; Gish, Nathan; Gish, Joshua; Carr, Benjamin; McLeod, Jennifer S; Church, Joseph T; Hsieh, Lily; Matusko, Niki; Geiger, James D; Hirschl, Ronald B; Gadepalli, Samir K
2018-02-01
Interestingly, the pediatric and adult surgeons perform vastly different operations in similar patient populations. Little is known about long-term recurrence and quality of life (QOL) in adolescents and young adults undergoing inguinal hernia repair. We evaluated long-term patient-centered outcomes in this population to determine the optimal operative approach. The medical records of patients 12-25 years old at the time of a primary inguinal hernia repair at our institution from 2000 to 2016 were retrospectively reviewed. Patients then completed a phone survey of their postoperative courses and QOL. Outcomes of high ligation performed by pediatric surgeons were compared to those of mesh repairs by adult general surgeons. The primary outcome was recurrence. Secondary outcomes included time to recurrence, postoperative complications, and patient-centered outcomes. A Cox regression analysis was used to determine associations for recurrence. Of 213 patients identified, 143 (67.1%) were repaired by adult surgeons and 70 (32.9%) repaired by pediatric surgeons. Overall recurrence rate for the entire cohort was 5.7% with a median time to recurrence of 3.5 years (interquartile range 120-2155 days). High ligation and mesh repairs had similar rates of recurrence (6.3 versus 5.8, P = .57) and postoperative complications (17% versus 16%, P = .45). 101/213 (47%) patients completed the phone survey. Of those surveyed, 20% reported postoperative pain, 10% had residual numbness and tingling, and 10% of patients complained of intermittent bulging. Overall, a survey comparison showed no differences among subgroups. In adolescents and young adults, the long-term recurrence rate after inguinal hernia repair is ∼6% with time to recurrence approaching 4 years. Outcomes of high ligation and mesh repair are similar, highlighting the need for individualized approaches for this unique population.
A comparative study of an ABC and an artificial absorber for truncating finite element meshes
NASA Technical Reports Server (NTRS)
Oezdemir, T.; Volakis, John L.
1993-01-01
The type of mesh termination used in the context of finite element formulations plays a major role on the efficiency and accuracy of the field solution. The performance of an absorbing boundary condition (ABC) and an artificial absorber (a new concept) for terminating the finite element mesh was evaluated. This analysis is done in connection with the problem of scattering by a finite slot array in a thick ground plane. The two approximate mesh truncation schemes are compared with the exact finite element-boundary integral (FEM-BI) method in terms of accuracy and efficiency. It is demonstrated that both approximate truncation schemes yield reasonably accurate results even when the mesh is extended only 0.3 wavelengths away from the array aperture. However, the artificial absorber termination method leads to a substantially more efficient solution. Moreover, it is shown that the FEM-BI method remains quite competitive with the FEM-artificial absorber method when the FFT is used for computing the matrix-vector products in the iterative solution algorithm. These conclusions are indeed surprising and of major importance in electromagnetic simulations based on the finite element method.
Smietański, M; Bigda, J; Zaborowski, K; Worek, M; Sledziński, Z
2009-06-01
This prospective cohort study evaluated whether partially absorbable monofilament mesh could influence postoperative pain and time of the return to normal activity while not increasing recurrence in modified Lichtenstein inguinal hernioplasty. Two hundred and forty-two patients were operated on using poliglecaprone/polypropylene mesh. A modified Lichtenstein technique was used (more stitches and larger margin of mesh on the inguinal ligament, additional suture near the pubic bone). Follow-up data were collected at 3 years. The objective was to assess the incidence of late persistent postoperative pain and the recurrence rate. The follow-up rate reached 88.37%. The recurrence rate was 2.2% (four patients). All recurrences appeared within the first 12 months. Slight discomfort, feelings of stiffness, and the occasional appearance of foreign bodies that did not influence daily activity were noted in 20 patients (10.8%). Chronic pain was found in 22 patients (11.1%), but only affected the daily activities of seven (3.24%). Only one patient suffering from pain described it as stronger than before the operation. The use of partially absorbable light mesh reduces postoperative pain at long-term follow-up. The recurrence rate was not increased at 36 months follow-up.
NASA Astrophysics Data System (ADS)
Bradley, A. M.
2013-12-01
My poster will describe dc3dm, a free open source software (FOSS) package that efficiently forms and applies the linear operator relating slip and traction components on a nonuniformly discretized rectangular planar fault in a homogeneous elastic (HE) half space. This linear operator implements what is called the displacement discontinuity method (DDM). The key properties of dc3dm are: 1. The mesh can be nonuniform. 2. Work and memory scale roughly linearly in the number of elements (rather than quadratically). 3. The order of accuracy of my method on a nonuniform mesh is the same as that of the standard method on a uniform mesh. Property 2 is achieved using my FOSS package hmmvp [AGU 2012]. A nonuniform mesh (property 1) is natural for some problems. For example, in a rate-state friction simulation, nucleation length, and so required element size, scales reciprocally with effective normal stress. Property 3 assures that if a nonuniform mesh is more efficient than a uniform mesh (in the sense of accuracy per element) at one level of mesh refinement, it will remain so at all further mesh refinements. I use the routine DC3D of Y. Okada, which calculates the stress tensor at a receiver resulting from a rectangular uniform dislocation source in an HE half space. On a uniform mesh, straightforward application of this Green's function (GF) yields a DDM I refer to as DDMu. On a nonuniform mesh, this same procedure leads to artifacts that degrade the order of accuracy of the DDM. I have developed a method I call IGA that implements the DDM using this GF for a nonuniformly discretized mesh having certain properties. Importantly, IGA's order of accuracy on a nonuniform mesh is the same as DDMu's on a uniform one. Boundary conditions can be periodic in the surface-parallel direction (in both directions if the GF is for a whole space), velocity on any side, and free surface. The mesh must have the following main property: each uniquely sized element must tile each element larger than itself. A mesh generated by a family of quadtrees has this property. Using multiple quadtrees that collectively cover the domain enables the elements to have a small aspect ratio. Mathematically, IGA works as follows. Let Mn be the nonuniform mesh. Define Mu to be the uniform mesh that is composed of the smallest element in Mn. Every element e in Mu has associated subelements in Mn that tile e. First, a linear operator Inu mapping data on Mn to Mu implements smooth (C^1) interpolation; I use cubic (Clough-Tocher) interpolation over a triangulation induced by Mn. Second, a linear operator Gu implements DDMu on Mu. Third, a linear operator Aun maps data on Mu to Mn. These three linear operators implement exact IGA (EIGA): Gn = Aun Gu Inu. Computationally, there are several more details. EIGA has the undesirable property that calculating one entry of Gn for receiver ri requires calculating multiple entries of Gu, no matter how far away from ri the smallest element is. Approximate IGA (AIGA) solves this problem by restricting EIGA to a neighborhood around each receiver. Associated with each neighborhood is a minimum element size s^i that indexes a family of operators Gu^i. The order of accuracy of AIGA is the same as that of EIGA and DDMu if each neighborhood is kept constant in spatial extent as the mesh is refined.
Characterization of prostate neuroendocrine cancers and therapeutic management: a literature review.
Sargos, P; Ferretti, L; Gross-Goupil, M; Orre, M; Cornelis, F; Henriques de Figueiredo, B; Houédé, N; Merino, C; Roubaud, G; Dallaudiére, B; Richaud, P; Fléchon, A
2014-09-01
Neuroendocrine prostate cancers (NEPCs) are rare. The current lack of consensus for clinical, biological and pathological characterization as well as therapeutic approach makes the management of those tumors a clinical challenge. This literature review aims to summarize available data on the characterization and management of patients with prostate cancer with a neuroendocrine element. We try to identify major controversies and uncertainties in order to understand all aspects of this particular entity. We searched for all articles published and registered in the MEDLINE database before 31 November 2013 with the following search terms: (('prostatic neoplasms' (MeSH Terms)) AND ('carcinoma, neuroendocrine' (MeSH Terms)) OR ('carcinoma, small cell' (MeSH Terms))) AND (English (Language)). Case reports, letters or comments were excluded. We then selected relevant articles from titles and abstracts. Overall, 278 articles published between 1976 and November 2013 were identified. No definition of NEPC seems to be clearly established. Natural history of the disease reveals poor prognosis with median survival of up to 10 to 13 months. Histological characterization appears difficult. Serum markers could be helpful with some controversies in terms of prognostic significance. Concerning management, the majority of patients received local treatment combined with chemotherapy in case of early and localized disease. Few clinical trials described strategy for metastatic disease. The exploration of the different pathways implicated in the neuroendocrine differentiation of prostate cancers is essential for the comprehension of castration-resistance mechanisms. It will enable the identification of optimal therapeutic strategies for which no recommendation is currently established. Inclusion in prospective clinical trials appears necessary to identify the adequate strategy.
4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling
NASA Astrophysics Data System (ADS)
Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing
2016-02-01
A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.
4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling.
Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing
2016-02-07
A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.
4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling
Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing
2016-01-01
A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp–Davis–Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations. PMID:26758496
Tsuji, Shintarou; Nishimoto, Naoki; Ogasawara, Katsuhiko
2008-07-20
Although large medical texts are stored in electronic format, they are seldom reused because of the difficulty of processing narrative texts by computer. Morphological analysis is a key technology for extracting medical terms correctly and automatically. This process parses a sentence into its smallest unit, the morpheme. Phrases consisting of two or more technical terms, however, cause morphological analysis software to fail in parsing the sentence and output unprocessed terms as "unknown words." The purpose of this study was to reduce the number of unknown words in medical narrative text processing. The results of parsing the text with additional dictionaries were compared with the analysis of the number of unknown words in the national examination for radiologists. The ratio of unknown words was reduced 1.0% to 0.36% by adding terminologies of radiological technology, MeSH, and ICD-10 labels. The terminology of radiological technology was the most effective resource, being reduced by 0.62%. This result clearly showed the necessity of additional dictionary selection and trends in unknown words. The potential for this investigation is to make available a large body of clinical information that would otherwise be inaccessible for applications other than manual health care review by personnel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schunert, Sebastian; Wang, Yaqi; Gleicher, Frederick
This paper presents a flexible nonlinear diffusion acceleration (NDA) method that discretizes both the S N transport equation and the diffusion equation using the discontinuous finite element method (DFEM). The method is flexible in that the diffusion equation can be discretized on a coarser mesh with the only restriction that it is nested within the transport mesh and the FEM shape function orders of the two equations can be different. The consistency of the transport and diffusion solutions at convergence is defined by using a projection operator mapping the transport into the diffusion FEM space. The diffusion weak form ismore » based on the modified incomplete interior penalty (MIP) diffusion DFEM discretization that is extended by volumetric drift, interior face, and boundary closure terms. In contrast to commonly used coarse mesh finite difference (CMFD) methods, the presented NDA method uses a full FEM discretized diffusion equation for acceleration. Suitable projection and prolongation operators arise naturally from the FEM framework. Via Fourier analysis and numerical experiments for a one-group, fixed source problem the following properties of the NDA method are established for structured quadrilateral meshes: (1) the presented method is unconditionally stable and effective in the presence of mild material heterogeneities if the same mesh and identical shape functions either of the bilinear or biquadratic type are used, (2) the NDA method remains unconditionally stable in the presence of strong heterogeneities, (3) the NDA method with bilinear elements extends the range of effectiveness and stability by a factor of two when compared to CMFD if a coarser diffusion mesh is selected. In addition, the method is tested for solving the C5G7 multigroup, eigenvalue problem using coarse and fine mesh acceleration. Finally, while NDA does not offer an advantage over CMFD for fine mesh acceleration, it reduces the iteration count required for convergence by almost a factor of two in the case of coarse mesh acceleration.« less
Schunert, Sebastian; Wang, Yaqi; Gleicher, Frederick; ...
2017-02-21
This paper presents a flexible nonlinear diffusion acceleration (NDA) method that discretizes both the S N transport equation and the diffusion equation using the discontinuous finite element method (DFEM). The method is flexible in that the diffusion equation can be discretized on a coarser mesh with the only restriction that it is nested within the transport mesh and the FEM shape function orders of the two equations can be different. The consistency of the transport and diffusion solutions at convergence is defined by using a projection operator mapping the transport into the diffusion FEM space. The diffusion weak form ismore » based on the modified incomplete interior penalty (MIP) diffusion DFEM discretization that is extended by volumetric drift, interior face, and boundary closure terms. In contrast to commonly used coarse mesh finite difference (CMFD) methods, the presented NDA method uses a full FEM discretized diffusion equation for acceleration. Suitable projection and prolongation operators arise naturally from the FEM framework. Via Fourier analysis and numerical experiments for a one-group, fixed source problem the following properties of the NDA method are established for structured quadrilateral meshes: (1) the presented method is unconditionally stable and effective in the presence of mild material heterogeneities if the same mesh and identical shape functions either of the bilinear or biquadratic type are used, (2) the NDA method remains unconditionally stable in the presence of strong heterogeneities, (3) the NDA method with bilinear elements extends the range of effectiveness and stability by a factor of two when compared to CMFD if a coarser diffusion mesh is selected. In addition, the method is tested for solving the C5G7 multigroup, eigenvalue problem using coarse and fine mesh acceleration. Finally, while NDA does not offer an advantage over CMFD for fine mesh acceleration, it reduces the iteration count required for convergence by almost a factor of two in the case of coarse mesh acceleration.« less
The Importance of Registries in the Postmarketing Surveillance of Surgical Meshes.
Köckerling, Ferdinand; Simon, Thomas; Hukauf, Martin; Hellinger, Achim; Fortelny, Rene; Reinpold, Wolfgang; Bittner, Reinhard
2017-06-07
To assess the role of registries in the postmarketing surveillance of surgical meshes. To date, surgical meshes are classified as group II medical devices. Class II devices do not require premarket clearance by clinical studies. Ethicon initiated a voluntary market withdrawal of Physiomesh for laparoscopic use after an analysis of unpublished data from the 2 large independent hernia registries-Herniamed German Registry and Danish Hernia Database. This paper now presents the relevant data from the Herniamed Registry. The present analysis compares the prospective perioperative and 1-year follow-up data collected for all patients with incisional hernia who had undergone elective laparoscopic intraperitoneal onlay mesh repair either with Physiomesh (n = 1380) or with other meshes recommended in the guidelines (n = 3834). Patients with Physiomesh repair had a markedly higher recurrence rate compared with the other recommended meshes (12.0% vs 5.0%; P < 0.001). In the multivariable analysis, the recurrence rate was highly significantly influenced by the mesh type used (P < 0.001). If Physiomesh was used, that led to a highly significant increase in the recurrence rate on 1-year follow-up (odds ratio 2.570, 95% CI 2.057, 3.210). The mesh type used also had a significant influence on chronic pain rates. The importance of real-world data for postmarketing surveillance of surgical meshes has been demonstrated in this registry-based study. Randomized controlled trials are needed for premarket approval of new devices. The role of sponsorship of device studies by the manufacturing company must be taken into account.This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0.
Fluid intake from beverages across age groups: a systematic review.
Özen, A E; Bibiloni, M Del Mar; Pons, A; Tur, J A
2015-10-01
Fluid intake, especially water, is essential for human life and also necessary for physical and mental function. The present study aimed to assess beverage consumption across age groups. A systematic review was conducted. Original research in English language publications and available studies (or abstracts in English) from 2000 to 2013 was searched for by using the medical subheading (MeSH) terms: ('beverage' OR 'fluid' [Major]) AND ('consumption' [Mesh] OR 'drinking' [Mesh] OR 'intake' [Mesh]) AND ('child' [Mesh] OR 'adolescent' [Mesh] OR 'adult' [Mesh]). Article selection was restricted to those papers covering healthy populations of all age groups in a nationwide sample, or from a representative sample of the population of a city or cities, which examined the trends or patterns of beverage intake and the determinants of beverage intake. Sixty-five studies were identified with respect to beverage consumption across age groups. The papers were screened by thoroughly reading titles or abstracts. Full-text articles were assessed by three investigators. Total beverage intake varied between 0.6 and 3.5 L day(-1) among all age groups (males more than females). Plain water contributed up to 58%, 75% and 80% of the total beverage intake in children, adolescents and adults, respectively. Milk consumption was higher among children; consumption of soft drinks was higher among adolescents; and the consumption of tea, coffee and alcoholic beverages was higher among adults. Plain water is the main water source for all age groups and the consumption of other beverages varies according to age. © 2014 The British Dietetic Association Ltd.
Microbial Formation of Dimethyl Sulfide in Anoxic Sphagnum Peat
Kiene, R. P.; Hines, M. E.
1995-01-01
Peat bogs dominated by Sphagnum spp. have relatively high areal rates of dimethyl sulfide (DMS) emission to the atmosphere. DMS was produced in anoxic slurries of Sphagnum peat with a linear time course and with an average rate of 40.4 (range, 22.0 to 68.6) nmol per liter of slurry (middot) day(sup-1) observed in nine batches of slurry. Methanethiol (MeSH) was produced at roughly similar rates over the typical 4- to 8-day incubations. DMS and MeSH production in these acidic (pH 4.2 to 4.6) peats were biological, as they were stopped completely by autoclaving and inhibited strongly by addition of antibiotics and 500 (mu)M chloroform. Endogenous DMS production may be due to the degradation of S-methyl-methionine, dimethyl sulfoxide, or methoxyaromatic compounds (e.g., syringic acid), each of which stimulated DMS formation when added at 5 to 10 (mu)M concentrations. However, on the basis of the high rates of thiol (MeSH and ethanethiol) methylation activity that we observed and the availability of endogenous MeSH, we suggest that methylation of MeSH is the major pathway leading to DMS formation in anaerobic peat. Solid-phase adsorption of MeSH plays a key role in its availability for biomethylation reactions. Additions of acetate (1.5 mM) or compounds which could cause acetate to accumulate (e.g., glucose, alanine, and 2-bromoethanesulfonate) suppressed DMS formation. It is likely that acetogenic bacteria are involved in DMS formation, but our data are insufficient to allow firm conclusions about the metabolic pathways or organisms involved. Our observations are the first which point to the methylation of MeSH as the major mechanism for endogenous DMS production in any environment. The rates of net DMS production observed are sufficient to explain the relatively high fluxes of DMS emitted to the atmosphere from Sphagnum sp.-dominated wetlands. PMID:16535080
Modeling, Modal Properties, and Mesh Stiffness Variation Instabilities of Planetary Gears
NASA Technical Reports Server (NTRS)
Parker, Robert G.; Lin, Jian; Krantz, Timothy L. (Technical Monitor)
2001-01-01
Planetary gear noise and vibration are primary concerns in their applications in helicopters, automobiles, aircraft engines, heavy machinery and marine vehicles. Dynamic analysis is essential to the noise and vibration reduction. This work analytically investigates some critical issues and advances the understanding of planetary gear dynamics. A lumped-parameter model is built for the dynamic analysis of general planetary gears. The unique properties of the natural frequency spectra and vibration modes are rigorously characterized. These special structures apply for general planetary gears with cyclic symmetry and, in practically important case, systems with diametrically opposed planets. The special vibration properties are useful for subsequent research. Taking advantage of the derived modal properties, the natural frequency and vibration mode sensitivities to design parameters are investigated. The key parameters include mesh stiffnesses, support/bearing stiffnesses, component masses, moments of inertia, and operating speed. The eigen-sensitivities are expressed in simple, closed-form formulae associated with modal strain and kinetic energies. As disorders (e.g., mesh stiffness variation. manufacturing and assembling errors) disturb the cyclic symmetry of planetary gears, their effects on the free vibration properties are quantitatively examined. Well-defined veering rules are derived to identify dramatic changes of natural frequencies and vibration modes under parameter variations. The knowledge of free vibration properties, eigen-sensitivities, and veering rules provide important information to effectively tune the natural frequencies and optimize structural design to minimize noise and vibration. Parametric instabilities excited by mesh stiffness variations are analytically studied for multi-mesh gear systems. The discrepancies of previous studies on parametric instability of two-stage gear chains are clarified using perturbation and numerical methods. The operating conditions causing parametric instabilities are expressed in closed-form suitable for design guidance. Using the well-defined modal properties of planetary gears, the effects of mesh parameters on parametric instability are analytically identified. Simple formulae are obtained to suppress particular instabilities by adjusting contact ratios and mesh phasing.
Nonlinear dynamics of planetary gears using analytical and finite element models
NASA Astrophysics Data System (ADS)
Ambarisha, Vijaya Kumar; Parker, Robert G.
2007-05-01
Vibration-induced gear noise and dynamic loads remain key concerns in many transmission applications that use planetary gears. Tooth separations at large vibrations introduce nonlinearity in geared systems. The present work examines the complex, nonlinear dynamic behavior of spur planetary gears using two models: (i) a lumped-parameter model, and (ii) a finite element model. The two-dimensional (2D) lumped-parameter model represents the gears as lumped inertias, the gear meshes as nonlinear springs with tooth contact loss and periodically varying stiffness due to changing tooth contact conditions, and the supports as linear springs. The 2D finite element model is developed from a unique finite element-contact analysis solver specialized for gear dynamics. Mesh stiffness variation excitation, corner contact, and gear tooth contact loss are all intrinsically considered in the finite element analysis. The dynamics of planetary gears show a rich spectrum of nonlinear phenomena. Nonlinear jumps, chaotic motions, and period-doubling bifurcations occur when the mesh frequency or any of its higher harmonics are near a natural frequency of the system. Responses from the dynamic analysis using analytical and finite element models are successfully compared qualitatively and quantitatively. These comparisons validate the effectiveness of the lumped-parameter model to simulate the dynamics of planetary gears. Mesh phasing rules to suppress rotational and translational vibrations in planetary gears are valid even when nonlinearity from tooth contact loss occurs. These mesh phasing rules, however, are not valid in the chaotic and period-doubling regions.
Garcia-Cantero, Juan J.; Brito, Juan P.; Mata, Susana; Bayona, Sofia; Pastor, Luis
2017-01-01
Gaining a better understanding of the human brain continues to be one of the greatest challenges for science, largely because of the overwhelming complexity of the brain and the difficulty of analyzing the features and behavior of dense neural networks. Regarding analysis, 3D visualization has proven to be a useful tool for the evaluation of complex systems. However, the large number of neurons in non-trivial circuits, together with their intricate geometry, makes the visualization of a neuronal scenario an extremely challenging computational problem. Previous work in this area dealt with the generation of 3D polygonal meshes that approximated the cells’ overall anatomy but did not attempt to deal with the extremely high storage and computational cost required to manage a complex scene. This paper presents NeuroTessMesh, a tool specifically designed to cope with many of the problems associated with the visualization of neural circuits that are comprised of large numbers of cells. In addition, this method facilitates the recovery and visualization of the 3D geometry of cells included in databases, such as NeuroMorpho, and provides the tools needed to approximate missing information such as the soma’s morphology. This method takes as its only input the available compact, yet incomplete, morphological tracings of the cells as acquired by neuroscientists. It uses a multiresolution approach that combines an initial, coarse mesh generation with subsequent on-the-fly adaptive mesh refinement stages using tessellation shaders. For the coarse mesh generation, a novel approach, based on the Finite Element Method, allows approximation of the 3D shape of the soma from its incomplete description. Subsequently, the adaptive refinement process performed in the graphic card generates meshes that provide good visual quality geometries at a reasonable computational cost, both in terms of memory and rendering time. All the described techniques have been integrated into NeuroTessMesh, available to the scientific community, to generate, visualize, and save the adaptive resolution meshes. PMID:28690511
Terrain-driven unstructured mesh development through semi-automatic vertical feature extraction
NASA Astrophysics Data System (ADS)
Bilskie, Matthew V.; Coggin, David; Hagen, Scott C.; Medeiros, Stephen C.
2015-12-01
A semi-automated vertical feature terrain extraction algorithm is described and applied to a two-dimensional, depth-integrated, shallow water equation inundation model. The extracted features describe what are commonly sub-mesh scale elevation details (ridge and valleys), which may be ignored in standard practice because adequate mesh resolution cannot be afforded. The extraction algorithm is semi-automated, requires minimal human intervention, and is reproducible. A lidar-derived digital elevation model (DEM) of coastal Mississippi and Alabama serves as the source data for the vertical feature extraction. Unstructured mesh nodes and element edges are aligned to the vertical features and an interpolation algorithm aimed at minimizing topographic elevation error assigns elevations to mesh nodes via the DEM. The end result is a mesh that accurately represents the bare earth surface as derived from lidar with element resolution in the floodplain ranging from 15 m to 200 m. To examine the influence of the inclusion of vertical features on overland flooding, two additional meshes were developed, one without crest elevations of the features and another with vertical features withheld. All three meshes were incorporated into a SWAN+ADCIRC model simulation of Hurricane Katrina. Each of the three models resulted in similar validation statistics when compared to observed time-series water levels at gages and post-storm collected high water marks. Simulated water level peaks yielded an R2 of 0.97 and upper and lower 95% confidence interval of ∼ ± 0.60 m. From the validation at the gages and HWM locations, it was not clear which of the three model experiments performed best in terms of accuracy. Examination of inundation extent among the three model results were compared to debris lines derived from NOAA post-event aerial imagery, and the mesh including vertical features showed higher accuracy. The comparison of model results to debris lines demonstrates that additional validation techniques are necessary for state-of-the-art flood inundation models. In addition, the semi-automated, unstructured mesh generation process presented herein increases the overall accuracy of simulated storm surge across the floodplain without reliance on hand digitization or sacrificing computational cost.
NASA Astrophysics Data System (ADS)
Farquharson, C.; Long, J.; Lu, X.; Lelievre, P. G.
2017-12-01
Real-life geology is complex, and so, even when allowing for the diffusive, low resolution nature of geophysical electromagnetic methods, we need Earth models that can accurately represent this complexity when modelling and inverting electromagnetic data. This is particularly the case for the scales, detail and conductivity contrasts involved in mineral and hydrocarbon exploration and development, but also for the larger scale of lithospheric studies. Unstructured tetrahedral meshes provide a flexible means of discretizing a general, arbitrary Earth model. This is important when wanting to integrate a geophysical Earth model with a geological Earth model parameterized in terms of surfaces. Finite-element and finite-volume methods can be derived for computing the electric and magnetic fields in a model parameterized using an unstructured tetrahedral mesh. A number of such variants have been proposed and have proven successful. However, the efficiency and accuracy of these methods can be affected by the "quality" of the tetrahedral discretization, that is, how many of the tetrahedral cells in the mesh are long, narrow and pointy. This is particularly the case if one wants to use an iterative technique to solve the resulting linear system of equations. One approach to deal with this issue is to develop sophisticated model and mesh building and manipulation capabilities in order to ensure that any mesh built from geological information is of sufficient quality for the electromagnetic modelling. Another approach is to investigate other methods of synthesizing the electromagnetic fields. One such example is a "meshfree" approach in which the electromagnetic fields are synthesized using a mesh that is distinct from the mesh used to parameterized the Earth model. There are then two meshes, one describing the Earth model and one used for the numerical mathematics of computing the fields. This means that there are no longer any quality requirements on the model mesh, which makes the process of building a geophysical Earth model from a geological model much simpler. In this presentation we will explore the issues that arise when working with realistic Earth models and when synthesizing geophysical electromagnetic data for them. We briefly consider meshfree methods as a possible means of alleviating some of these issues.
Nanotechnology Infrared Optics for Astronomy Missions
NASA Technical Reports Server (NTRS)
Frogel, Jay (Technical Monitor); Smith, Howard A.
2004-01-01
We have used the "MicroStripes" code (Flomerics, Inc.) to perform full-, near- and far-field diffraction modeling of metal mesh performance on substrates. Our Miles Code software, which approximates the full calculation in a quick, gui-based window, is useful as an iterative device by adjusting the input parameters (index of refraction, thickness, etc.) to provide agreement with the full calculation. However, despite the somewhat extravagant claims by the MicroStripes manufacturer, this code is also not perfect because numerous free parameters must be set. Key among these, as identified in our earlier papers and proposal documents, is the high frequency (i.e., far IR) character of the real and imaginary parts of the index of refraction of the metal mesh, the high frequency character of the real and imaginary parts of the index of refraction of the substrate, and the character of the interface between the mesh and the substrate material, and in particular the suppression (or possible enhancement) of surface effects at the interface.
Liang, Rui; Knight, Katrina; Barone, William; Powers, Robert W; Nolfi, Alexis; Palcsey, Stacy; Abramowitch, Steven; Moalli, Pamela A
2017-02-01
The use of wide pore lightweight polypropylene mesh to improve anatomical outcomes in the surgical repair of prolapse has been hampered by mesh complications. One of the prototype prolapse meshes has been found to negatively impact the vagina by inducing a decrease in smooth muscle volume and contractility and the degradation of key structural proteins (collagen and elastin), resulting in vaginal degeneration. Recently, bioscaffolds derived from extracellular matrix have been used to mediate tissue regeneration and have been widely adopted in tissue engineering applications. Here we aimed to: (1) define whether augmentation of a polypropylene prolapse mesh with an extracellular matrix regenerative graft in a primate sacrocolpopexy model could mitigate the degenerative changes; and (2) determine the impact of the extracellular matrix graft on vagina when implanted alone. A polypropylene-extracellular matrix composite graft (n = 9) and a 6-layered extracellular matrix graft alone (n = 8) were implanted in 17 middle-aged parous rhesus macaques via sacrocolpopexy and compared to historical data obtained from sham (n = 12) and the polypropylene mesh (n = 12) implanted by the same method. Vaginal function was measured in passive (ball-burst test) and active (smooth muscle contractility) mechanical tests. Vaginal histomorphologic/biochemical assessments included hematoxylin-eosin and trichrome staining, immunofluorescent labeling of α-smooth muscle actin and apoptotic cells, measurement of total collagen, collagen subtypes (ratio III/I), mature elastin, and sulfated glycosaminoglycans. Statistical analyses included 1-way analysis of variance, Kruskal-Wallis, and appropriate post-hoc tests. The host inflammatory response in the composite mesh-implanted vagina was reduced compared to that following implantation with the polypropylene mesh alone. The increase in apoptotic cells observed with the polypropylene mesh was blunted in the composite (overall P < .001). Passive mechanical testing showed inferior parameters for both polypropylene mesh alone and the composite compared to sham whereas the contractility and thickness of smooth muscle layer in the composite were improved with a value similar to sham, which was distinct from the decreases observed with polypropylene mesh alone. Biochemically, the composite had similar mature elastin content, sulfated glycosaminoglycan content, and collagen subtype III/I ratio but lower total collagen content when compared to sham (P = .011). Multilayered extracellular matrix graft alone showed overall comparable values to sham in aspects of the biomechanical, histomorphologic, or biochemical endpoints of the vagina. The increased collagen subtype ratio III/I with the extracellular matrix graft alone (P = .033 compared to sham) is consistent with an ongoing active remodeling response. Mesh augmentation with a regenerative extracellular matrix graft attenuated the negative impact of polypropylene mesh on the vagina. Application of the extracellular matrix graft alone had no measurable negative effects suggesting that the benefits of this extracellular matrix graft occur when used without a permanent material. Future studies will focus on understanding mechanisms. Copyright © 2016. Published by Elsevier Inc.
Liang, Rui; Knight, Katrina; Barone, William; Powers, Robert W.; Nolfi, Alexis; Palcsey, Stacy; Abramowitch, Steven; Moalli, Pamela A.
2016-01-01
BACKGROUND The use of wide pore lightweight polypropylene mesh to improve anatomical outcomes in the surgical repair of prolapse has been hampered by mesh complications. One of the prototype prolapse meshes has been found to negatively impact the vagina by inducing a decrease in smooth muscle volume and contractility and the degradation of key structural proteins (collagen and elastin), resulting in vaginal degeneration. Recently, bioscaffolds derived from extracellular matrix have been used to mediate tissue regeneration and have been widely adopted in tissue engineering applications. OBJECTIVE Here we aimed to: (1) define whether augmentation of a polypropylene prolapse mesh with an extracellular matrix regenerative graft in a primate sacrocolpopexy model could mitigate the degenerative changes; and (2) determine the impact of the extracellular matrix graft on vagina when implanted alone. STUDY DESIGN A polypropylene-extracellular matrix composite graft (n = 9) and a 6-layered extracellular matrix graft alone (n = 8) were implanted in 17 middle-aged parous rhesus macaques via sacrocolpopexy and compared to historical data obtained from sham (n = 12) and the polypropylene mesh (n = 12) implanted by the same method. Vaginal function was measured in passive (ball-burst test) and active (smooth muscle contractility) mechanical tests. Vaginal histomorphologic/ biochemical assessments included hematoxylin-eosin and trichrome staining, immunofluorescent labeling of α-smooth muscle actin and apoptotic cells, measurement of total collagen, collagen subtypes (ratio III/ I), mature elastin, and sulfated glycosaminoglycans. Statistical analyses included 1-way analysis of variance, Kruskal-Wallis, and appropriate posthoc tests. RESULTS The host inflammatory response in the composite mesh-implanted vagina was reduced compared to that following implantation with the polypropylene mesh alone. The increase in apoptotic cells observed with the polypropylene mesh was blunted in the composite (overall P < .001). Passive mechanical testing showed inferior parameters for both polypropylene mesh alone and the composite compared to sham whereas the contractility and thickness of smooth muscle layer in the composite were improved with a value similar to sham, which was distinct from the decreases observed with polypropylene mesh alone. Biochemically, the composite had similar mature elastin content, sulfated glycosaminoglycan content, and collagen subtype III/I ratio but lower total collagen content when compared to sham (P = .011). Multilayered extracellular matrix graft alone showed overall comparable values to sham in aspects of the biomechanical, histomorphologic, or biochemical end-points of the vagina. The increased collagen subtype ratio III/I with the extracellular matrix graft alone (P = .033 compared to sham) is consistent with an ongoing active remodeling response. CONCLUSION Mesh augmentation with a regenerative extracellular matrix graft attenuated the negative impact of polypropylene mesh on the vagina. Application of the extracellular matrix graft alone had no measurable negative effects suggesting that the benefits of this extra-cellular matrix graft occur when used without a permanent material. Future studies will focus on understanding mechanisms. PMID:27615441
Alagl, Adel S; Madi, Marwa
2018-05-01
Alveolar ridge deficiency is considered a major limitation for successful implant placement, as well as for the long-term success rate, especially in the anterior maxillary region. Various approaches have been developed to increase bone volume. Among those approaches, inlay and onlay grafts, alveolar ridge distraction, and guided bone regeneration have been suggested. The use of titanium mesh is a reliable method for ridge augmentation. We describe a patient who presented with a localized, combined, horizontal and vertical ridge defect in the anterior maxilla. The patient was treated using titanium mesh and alloplast material mixed with a nano-bone graft to treat the localized ridge deformity for future implant installation. The clinical and radiographic presentation, as well as relevant literature, are presented.
Adaptive radial basis function mesh deformation using data reduction
NASA Astrophysics Data System (ADS)
Gillebaart, T.; Blom, D. S.; van Zuijlen, A. H.; Bijl, H.
2016-09-01
Radial Basis Function (RBF) mesh deformation is one of the most robust mesh deformation methods available. Using the greedy (data reduction) method in combination with an explicit boundary correction, results in an efficient method as shown in literature. However, to ensure the method remains robust, two issues are addressed: 1) how to ensure that the set of control points remains an accurate representation of the geometry in time and 2) how to use/automate the explicit boundary correction, while ensuring a high mesh quality. In this paper, we propose an adaptive RBF mesh deformation method, which ensures the set of control points always represents the geometry/displacement up to a certain (user-specified) criteria, by keeping track of the boundary error throughout the simulation and re-selecting when needed. Opposed to the unit displacement and prescribed displacement selection methods, the adaptive method is more robust, user-independent and efficient, for the cases considered. Secondly, the analysis of a single high aspect ratio cell is used to formulate an equation for the correction radius needed, depending on the characteristics of the correction function used, maximum aspect ratio, minimum first cell height and boundary error. Based on the analysis two new radial basis correction functions are derived and proposed. This proposed automated procedure is verified while varying the correction function, Reynolds number (and thus first cell height and aspect ratio) and boundary error. Finally, the parallel efficiency is studied for the two adaptive methods, unit displacement and prescribed displacement for both the CPU as well as the memory formulation with a 2D oscillating and translating airfoil with oscillating flap, a 3D flexible locally deforming tube and deforming wind turbine blade. Generally, the memory formulation requires less work (due to the large amount of work required for evaluating RBF's), but the parallel efficiency reduces due to the limited bandwidth available between CPU and memory. In terms of parallel efficiency/scaling the different studied methods perform similarly, with the greedy algorithm being the bottleneck. In terms of absolute computational work the adaptive methods are better for the cases studied due to their more efficient selection of the control points. By automating most of the RBF mesh deformation, a robust, efficient and almost user-independent mesh deformation method is presented.
Global/local methods for probabilistic structural analysis
NASA Technical Reports Server (NTRS)
Millwater, H. R.; Wu, Y.-T.
1993-01-01
A probabilistic global/local method is proposed to reduce the computational requirements of probabilistic structural analysis. A coarser global model is used for most of the computations with a local more refined model used only at key probabilistic conditions. The global model is used to establish the cumulative distribution function (cdf) and the Most Probable Point (MPP). The local model then uses the predicted MPP to adjust the cdf value. The global/local method is used within the advanced mean value probabilistic algorithm. The local model can be more refined with respect to the g1obal model in terms of finer mesh, smaller time step, tighter tolerances, etc. and can be used with linear or nonlinear models. The basis for this approach is described in terms of the correlation between the global and local models which can be estimated from the global and local MPPs. A numerical example is presented using the NESSUS probabilistic structural analysis program with the finite element method used for the structural modeling. The results clearly indicate a significant computer savings with minimal loss in accuracy.
Global/local methods for probabilistic structural analysis
NASA Astrophysics Data System (ADS)
Millwater, H. R.; Wu, Y.-T.
1993-04-01
A probabilistic global/local method is proposed to reduce the computational requirements of probabilistic structural analysis. A coarser global model is used for most of the computations with a local more refined model used only at key probabilistic conditions. The global model is used to establish the cumulative distribution function (cdf) and the Most Probable Point (MPP). The local model then uses the predicted MPP to adjust the cdf value. The global/local method is used within the advanced mean value probabilistic algorithm. The local model can be more refined with respect to the g1obal model in terms of finer mesh, smaller time step, tighter tolerances, etc. and can be used with linear or nonlinear models. The basis for this approach is described in terms of the correlation between the global and local models which can be estimated from the global and local MPPs. A numerical example is presented using the NESSUS probabilistic structural analysis program with the finite element method used for the structural modeling. The results clearly indicate a significant computer savings with minimal loss in accuracy.
Cinnamon in glycaemic control: Systematic review and meta analysis.
Akilen, Rajadurai; Tsiami, Amalia; Devendra, Devasenan; Robinson, Nicola
2012-10-01
Cinnamon seems to be highly bioactive, appearing to mimic the effect of insulin through increased glucose uptake in adipocytes and skeletal muscles. This systematic review and Meta analysis examined the effect of cinnamon on glycaemic control in patients with Type 2 Diabetes mellitus. A systematic literature search was conducted from the earliest possible date through to 01 August 2011. Search terms included free text terms, MeSH and Medline medical index terms such as: "cinnamon", "cinnamomum", "cinnamomum cassia", "cinnamomum zeylanicum", "type 2 diabetes mellitus". Each was crossed with the term "diabetes mellitus". In addition, references of key articles were hand searched. A total of 6 clinical trials met the strict inclusion criteria and considered a total of 435 patients; follow up between 40 days-4 months, doses ranging from 1 g to 6 g per day. Meta-analysis of RCTs showed a significant decrease in mean HbA1c [0.09%; 95% CI was 0.04-0.14] and mean FPG [0.84 mmol/l; 95% CI was 0.66-1.02]. Use of cinnamon showed a beneficial effect on glycaemic control (both HbA1c and FPG) and the short term (<4 months) effects of the use of cinnamon on glycaemic control looks promising. Copyright © 2012 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Parastomal hernias after radical cystectomy and ileal conduit diversion
Donahue, Timothy F.
2016-01-01
Parastomal hernia, defined as an "incisional hernia related to an abdominal wall stoma", is a frequent complication after conduit urinary diversion that can negatively impact quality of life and present a clinically significant problem for many patients. Parastomal hernia (PH) rates may be as high as 65% and while many patients are asymptomatic, in some series up to 30% of patients require surgical intervention due to pain, leakage, ostomy appliance problems, urinary obstruction, and rarely bowel obstruction or strangulation. Local tissue repair, stoma relocation, and mesh repairs have been performed to correct PH, however, long-term results have been disappointing with recurrence rates of 30%–76% reported after these techniques. Due to high recurrence rates and the potential morbidity of PH repair, efforts have been made to prevent PH development at the time of the initial surgery. Randomized trials of circumstomal prophylactic mesh placement at the time of colostomy and ileostomy stoma formation have shown significant reductions in PH rates with acceptably low complication profiles. We have placed prophylactic mesh at the time of ileal conduit creation in patients at high risk for PH development and found it to be safe and effective in reducing the PH rates over the short-term. In this review, we describe the clinical and radiographic definitions of PH, the clinical impact and risk factors associated with its development, and the use of prophylactic mesh placement for patients undergoing ileal conduit urinary diversion with the intent of reducing PH rates. PMID:27437533
Biomedical word sense disambiguation with ontologies and metadata: automation meets accuracy
Alexopoulou, Dimitra; Andreopoulos, Bill; Dietze, Heiko; Doms, Andreas; Gandon, Fabien; Hakenberg, Jörg; Khelif, Khaled; Schroeder, Michael; Wächter, Thomas
2009-01-01
Background Ontology term labels can be ambiguous and have multiple senses. While this is no problem for human annotators, it is a challenge to automated methods, which identify ontology terms in text. Classical approaches to word sense disambiguation use co-occurring words or terms. However, most treat ontologies as simple terminologies, without making use of the ontology structure or the semantic similarity between terms. Another useful source of information for disambiguation are metadata. Here, we systematically compare three approaches to word sense disambiguation, which use ontologies and metadata, respectively. Results The 'Closest Sense' method assumes that the ontology defines multiple senses of the term. It computes the shortest path of co-occurring terms in the document to one of these senses. The 'Term Cooc' method defines a log-odds ratio for co-occurring terms including co-occurrences inferred from the ontology structure. The 'MetaData' approach trains a classifier on metadata. It does not require any ontology, but requires training data, which the other methods do not. To evaluate these approaches we defined a manually curated training corpus of 2600 documents for seven ambiguous terms from the Gene Ontology and MeSH. All approaches over all conditions achieve 80% success rate on average. The 'MetaData' approach performed best with 96%, when trained on high-quality data. Its performance deteriorates as quality of the training data decreases. The 'Term Cooc' approach performs better on Gene Ontology (92% success) than on MeSH (73% success) as MeSH is not a strict is-a/part-of, but rather a loose is-related-to hierarchy. The 'Closest Sense' approach achieves on average 80% success rate. Conclusion Metadata is valuable for disambiguation, but requires high quality training data. Closest Sense requires no training, but a large, consistently modelled ontology, which are two opposing conditions. Term Cooc achieves greater 90% success given a consistently modelled ontology. Overall, the results show that well structured ontologies can play a very important role to improve disambiguation. Availability The three benchmark datasets created for the purpose of disambiguation are available in Additional file 1. PMID:19159460
NASA Technical Reports Server (NTRS)
Wood, William A., III
2002-01-01
A multi-dimensional upwind fluctuation splitting scheme is developed and implemented for two-dimensional and axisymmetric formulations of the Navier-Stokes equations on unstructured meshes. Key features of the scheme are the compact stencil, full upwinding, and non-linear discretization which allow for second-order accuracy with enforced positivity. Throughout, the fluctuation splitting scheme is compared to a current state-of-the-art finite volume approach, a second-order, dual mesh upwind flux difference splitting scheme (DMFDSFV), and is shown to produce more accurate results using fewer computer resources for a wide range of test cases. A Blasius flat plate viscous validation case reveals a more accurate upsilon-velocity profile for fluctuation splitting, and the reduced artificial dissipation production is shown relative to DMFDSFV. Remarkably, the fluctuation splitting scheme shows grid converged skin friction coefficients with only five points in the boundary layer for this case. The second half of the report develops a local, compact, anisotropic unstructured mesh adaptation scheme in conjunction with the multi-dimensional upwind solver, exhibiting a characteristic alignment behavior for scalar problems. The adaptation strategy is extended to the two-dimensional and axisymmetric Navier-Stokes equations of motion through the concept of fluctuation minimization.
Investing in Children. Worldwatch Paper 64.
ERIC Educational Resources Information Center
Chandler, William U.
This report emphasizes the need for action in improving human nutrition, health and the status of women in Third World countries. Special attention is directed to improvement in child health care practices. The report advocates a strategy that meshes short term needs of desperate families with long term requirements of ecological stability and…
Sanjay, Pandanaboyana; Harris, Dean; Jones, Philippa; Woodward, Alan
2006-07-01
There are no data regarding the long-term outcomes of prolene hernia system (PHS) mesh in the published reports. The aim of the study was to compare the short-term and long-term outcomes of the PHS mesh with the Lichtenstein mesh technique. Sixty-four patients with inguinal hernia were randomized to undergo either a PHS or a Lichtenstein repair under local anaesthesia as a day case. Early outcome measures were duration of surgery, pain scores, analgesic requirements, time to return to work, driving and full activity. Long-term outcome measures were chronic groin pain and recurrence. Mean duration of surgery in the PHS group was 36 min (SD +/- 11) versus 34 min in the Lichtenstein group (SD +/- 8; P = 0.3). There was no significant difference in analgesic requirements (P = 0.65). Overall mean pain score was 3.5/10 versus 2.5/10 (P = 0.1). Mean time to return to work was 42 versus 30 days (P = 0.3), returning to driving was 20 versus 14 days (P = 0.2) and full activity was 21 versus 22 days (P = 0.8). Chronic groin pain developed in four patients in the PHS group (12.9%) and in five patients in the Lichtenstein group (15.1%; P > 0.05). One patient developed recurrent herniation in the PHS group. The median follow up was 4.2 years (range, 4-4.6 years). Patient satisfaction was very high with both the techniques. There is no significant difference in the early and long-term outcomes between PHS and Lichtenstein hernia repairs. The PHS technique involving preperitoneal dissection is well tolerated and easy to carry out under local anaesthesia.
The Quality of Health Information Available on the Internet for Patients With Pelvic Organ Prolapse.
Solomon, Ellen R; Janssen, Kristine; Krajewski, Colleen M; Barber, Matthew D
2015-01-01
This study aimed to assess the quality of Web sites that provide information on pelvic organ prolapse using validated quality measurement tools. The Google search engine was used to perform a search of the following 4 terms: "pelvic organ prolapse," "dropped bladder," "cystocele," and "vaginal mesh." The DISCERN appraisal tool and JAMA benchmark criteria were used to determine the quality of health information of each Web site. Cohen κ was performed to determine interrater reliability between reviewers. Kruskal-Wallis and Wilcoxon rank sum tests were used to compare DISCERN scores and JAMA criteria among search terms. Interrater reliability between the two reviewers using DISCERN was κ = 0.71 [95% confidence interval (CI), 0.68-0.74] and using JAMA criteria was κ = 0.98 (95% CI, 0.74-1.0). On the basis of the DISCERN appraisal tool, the search term "vaginal mesh" had significantly lower Web site quality than "pelvic organ prolapse" and "cystocele," respectively [mean difference of DISCERN score, -14.65 (95% CI, -25.50 to 8.50, P < 0.0001) and -12.55 (95% CI, -24.00 to 7.00, P = 0.0007)]. "Dropped bladder" had significantly lower Web site quality compared to "pelvic organ prolapse" and "cystocele," respectively (mean difference of DISCERN score, -9.55 (95% CI, -20.00 to 3.00, P = 0.0098) and -7.80 (95% CI, -18.00 to 1.00, P = 0.0348). Using JAMA criteria, there were no statistically significant differences between Web sites. Web sites queried under search terms "vaginal mesh" and "dropped bladder" are lower in quality compared with the Web sites found using the search terms "pelvic organ prolapse" and "cystocele."
A Mechanistic Study of Wetting Superhydrophobic Porous 3D Meshes
Yohe, Stefan T.; Freedman, Jonathan D.; Falde, Eric J.; Colson, Yolonda L.; Grinstaff, Mark W.
2014-01-01
Superhydrophobic, porous, 3D materials composed of poly( ε -caprolactone) (PCL) and the hydrophobic polymer dopant poly(glycerol monostearate-co- ε -caprolactone) (PGC-C18) are fabricated using the electrospinning technique. These 3D materials are distinct from 2D superhydrophobic surfaces, with maintenance of air at the surface as well as within the bulk of the material. These superhydrophobic materials float in water, and when held underwater and pressed, an air bubble is released and will rise to the surface. By changing the PGC-C18 doping concentration in the meshes and/or the fiber size from the micro- to nanoscale, the long-term stability of the entrapped air layer is controlled. The rate of water infiltration into the meshes, and the resulting displacement of the entrapped air, is quantitatively measured using X-ray computed tomography. The properties of the meshes are further probed using surfactants and solvents of different surface tensions. Finally, the application of hydraulic pressure is used to quantify the breakthrough pressure to wet the meshes. The tools for fabrication and analysis of these superhydrophobic materials as well as the ability to control the robustness of the entrapped air layer are highly desirable for a number of existing and emerging applications. PMID:25309305
Pulmonary hypertensive crisis and its efficient management. A Case report and literature review.
Khan, Karima Karam; Khan, Fazal Hameed
2017-06-01
There is a staggering upsurge in the incidence of plagiarism of scientific literature. Literature shows divergent views about the factors that make plagiarism reprehensible. This review explores the causes and remedies for the perennial academic problem of plagiarism. Data sources were searched for full text English language articles published from 2000 to 2015. Data selection was done using medical subject headline (MeSH) terms plagiarism, unethical writing, academic theft, retraction, medical field, and plagiarism detection software. Data extraction was undertaken by selecting titles from retrieved references and data synthesis identified key factors leading to plagiarism such as unawareness of research ethics, poor writing skills and pressure or publish mantra. Plagiarism can be managed by a balance among its prevention, detection by plagiarism detection software, and institutional sanctions against proven plagiarists. Educating researchers about ethical principles of academic writing and institutional support in training writers about academic integrity and ethical publications can curtail plagiarism.
Two-dimensional strain gradient damage modeling: a variational approach
NASA Astrophysics Data System (ADS)
Placidi, Luca; Misra, Anil; Barchiesi, Emilio
2018-06-01
In this paper, we formulate a linear elastic second gradient isotropic two-dimensional continuum model accounting for irreversible damage. The failure is defined as the condition in which the damage parameter reaches 1, at least in one point of the domain. The quasi-static approximation is done, i.e., the kinetic energy is assumed to be negligible. In order to deal with dissipation, a damage dissipation term is considered in the deformation energy functional. The key goal of this paper is to apply a non-standard variational procedure to exploit the damage irreversibility argument. As a result, we derive not only the equilibrium equations but, notably, also the Karush-Kuhn-Tucker conditions. Finally, numerical simulations for exemplary problems are discussed as some constitutive parameters are varying, with the inclusion of a mesh-independence evidence. Element-free Galerkin method and moving least square shape functions have been employed.
NASA Astrophysics Data System (ADS)
Zahr, M. J.; Persson, P.-O.
2018-07-01
This work introduces a novel discontinuity-tracking framework for resolving discontinuous solutions of conservation laws with high-order numerical discretizations that support inter-element solution discontinuities, such as discontinuous Galerkin or finite volume methods. The proposed method aims to align inter-element boundaries with discontinuities in the solution by deforming the computational mesh. A discontinuity-aligned mesh ensures the discontinuity is represented through inter-element jumps while smooth basis functions interior to elements are only used to approximate smooth regions of the solution, thereby avoiding Gibbs' phenomena that create well-known stability issues. Therefore, very coarse high-order discretizations accurately resolve the piecewise smooth solution throughout the domain, provided the discontinuity is tracked. Central to the proposed discontinuity-tracking framework is a discrete PDE-constrained optimization formulation that simultaneously aligns the computational mesh with discontinuities in the solution and solves the discretized conservation law on this mesh. The optimization objective is taken as a combination of the deviation of the finite-dimensional solution from its element-wise average and a mesh distortion metric to simultaneously penalize Gibbs' phenomena and distorted meshes. It will be shown that our objective function satisfies two critical properties that are required for this discontinuity-tracking framework to be practical: (1) possesses a local minima at a discontinuity-aligned mesh and (2) decreases monotonically to this minimum in a neighborhood of radius approximately h / 2, whereas other popular discontinuity indicators fail to satisfy the latter. Another important contribution of this work is the observation that traditional reduced space PDE-constrained optimization solvers that repeatedly solve the conservation law at various mesh configurations are not viable in this context since severe overshoot and undershoot in the solution, i.e., Gibbs' phenomena, may make it impossible to solve the discrete conservation law on non-aligned meshes. Therefore, we advocate a gradient-based, full space solver where the mesh and conservation law solution converge to their optimal values simultaneously and therefore never require the solution of the discrete conservation law on a non-aligned mesh. The merit of the proposed method is demonstrated on a number of one- and two-dimensional model problems including the L2 projection of discontinuous functions, Burgers' equation with a discontinuous source term, transonic flow through a nozzle, and supersonic flow around a bluff body. We demonstrate optimal O (h p + 1) convergence rates in the L1 norm for up to polynomial order p = 6 and show that accurate solutions can be obtained on extremely coarse meshes.
Broadhurst, Matt K.; Sterling, David J.; Millar, Russell B.
2014-01-01
The effects of reducing mesh size while concomitantly varying the side taper and wing depth of a generic penaeid-trawl body were investigated to improve engineering performance and minimize bycatch. Five trawl bodies (with the same codends) were tested across various environmental (e.g. depth and current) and biological (e.g. species and sizes) conditions. The first trawl body comprised 41-mm mesh and represented conventional designs (termed the ‘41 long deep-wing'), while the remaining trawl bodies were made from 32-mm mesh and differed only in their side tapers, and therefore length (i.e. 1N3B or ‘long’ and ∼28o to the tow direction vs 1N5B or ‘short’ and ∼35o) and wing depths (‘deep’–97 T vs ‘shallow’–60 T). There were incremental drag reductions (and therefore fuel savings – by up to 18 and 12% per h and ha trawled) associated with reducing twine area via either modification, and subsequently minimizing otter-board area in attempts to standardize spread. Side taper and wing depth had interactive and varied effects on species selectivity, but compared to the conventional 41 long deep-wing trawl, the 32 short shallow-wing trawl (i.e. the least twine area) reduced the total bycatch by 57% (attributed to more fish swimming forward and escaping). In most cases, all small-meshed trawls also caught more smaller school prawns Metapenaeus macleayi but to decrease this effect it should be possible to increase mesh size slightly, while still maintaining the above engineering benefits and species selectivity. The results support precisely optimizing mesh size as a precursor to any other anterior penaeid-trawl modifications designed to improve environmental performance. PMID:24911786
An upwind multigrid method for solving viscous flows on unstructured triangular meshes. M.S. Thesis
NASA Technical Reports Server (NTRS)
Bonhaus, Daryl Lawrence
1993-01-01
A multigrid algorithm is combined with an upwind scheme for solving the two dimensional Reynolds averaged Navier-Stokes equations on triangular meshes resulting in an efficient, accurate code for solving complex flows around multiple bodies. The relaxation scheme uses a backward-Euler time difference and relaxes the resulting linear system using a red-black procedure. Roe's flux-splitting scheme is used to discretize convective and pressure terms, while a central difference is used for the diffusive terms. The multigrid scheme is demonstrated for several flows around single and multi-element airfoils, including inviscid, laminar, and turbulent flows. The results show an appreciable speed up of the scheme for inviscid and laminar flows, and dramatic increases in efficiency for turbulent cases, especially those on increasingly refined grids.
Overcoming Terminology Barrier Using Web Resources for Cross-Language Medical Information Retrieval
Lu, Wen-Hsiang; Lin, Ray Shih-Jui; Chan, Yi-Che; Chen, Kuan-Hsi
2006-01-01
A number of authoritative medical websites, such as PubMed and MedlinePlus, provide consumers with the most up-to-date health information. However, non-English speakers often encounter not only language barriers (from other languages to English) but also terminology barriers (from laypersons’ terms to professional medical terms) when retrieving information from these websites. Our previous work addresses language barriers by developing a multilingual medical thesaurus, Chinese-English MeSH, while this study presents an approach to overcome terminology barriers based on Web resources. Two techniques were utilized in our approach: monolingual concept mapping using approximate string matching and crosslingual concept mapping using Web resources. The evaluation shows that our approach can significantly improve the performance on MeSH concept mapping and cross-language medical information retrieval. PMID:17238395
Massive parallel 3D PIC simulation of negative ion extraction
NASA Astrophysics Data System (ADS)
Revel, Adrien; Mochalskyy, Serhiy; Montellano, Ivar Mauricio; Wünderlich, Dirk; Fantz, Ursel; Minea, Tiberiu
2017-09-01
The 3D PIC-MCC code ONIX is dedicated to modeling Negative hydrogen/deuterium Ion (NI) extraction and co-extraction of electrons from radio-frequency driven, low pressure plasma sources. It provides valuable insight on the complex phenomena involved in the extraction process. In previous calculations, a mesh size larger than the Debye length was used, implying numerical electron heating. Important steps have been achieved in terms of computation performance and parallelization efficiency allowing successful massive parallel calculations (4096 cores), imperative to resolve the Debye length. In addition, the numerical algorithms have been improved in terms of grid treatment, i.e., the electric field near the complex geometry boundaries (plasma grid) is calculated more accurately. The revised model preserves the full 3D treatment, but can take advantage of a highly refined mesh. ONIX was used to investigate the role of the mesh size, the re-injection scheme for lost particles (extracted or wall absorbed), and the electron thermalization process on the calculated extracted current and plasma characteristics. It is demonstrated that all numerical schemes give the same NI current distribution for extracted ions. Concerning the electrons, the pair-injection technique is found well-adapted to simulate the sheath in front of the plasma grid.
Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei
2017-02-01
BACKGROUND The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. MATERIAL AND METHODS Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate, and operative time were compared between the 2 groups. RESULTS Total effective rate was 100% in both groups. No long-term chronic pain occurred and discomfort rate of tenesmus was higher in the STARR group than in the TVMR group. Postoperative defecography showed that the rectocele depth was significantly reduced, and the prolapse of the rectal mucosa and the lower rectal capacity was also decreased. Four cases had mesh exposure in the TVMR group and 2 cases in the STARR group had anastomotic bleeding after the surgery. CONCLUSIONS For outlet obstruction constipation caused by rectocele, TVMR and STARR both obtained satisfactory results. Although TVMR is complex with longer operative time and hospitalization period, its long-term effect is better than that of STARR.
van Iersel, Jan J; Paulides, Tim J C; Verheijen, Paul M; Lumley, John W; Broeders, Ivo A M J; Consten, Esther C J
2016-06-07
External and internal rectal prolapse with their affiliated rectocele and enterocele, are associated with debilitating symptoms such as obstructed defecation, pelvic pain and faecal incontinence. Since perineal procedures are associated with a higher recurrence rate, an abdominal approach is commonly preferred. Despite the description of greater than three hundred different procedures, thus far no clear superiority of one surgical technique has been demonstrated. Ventral mesh rectopexy (VMR) is a relatively new and promising technique to correct rectal prolapse. In contrast to the abdominal procedures of past decades, VMR avoids posterolateral rectal mobilisation and thereby minimizes the risk of postoperative constipation. Because of a perceived acceptable recurrence rate, good functional results and low mesh-related morbidity in the short to medium term, VMR has been popularized in the past decade. Laparoscopic or robotic-assisted VMR is now being progressively performed internationally and several articles and guidelines propose the procedure as the treatment of choice for rectal prolapse. In this article, an outline of the current status of laparoscopic and robotic ventral mesh rectopexy for the treatment of internal and external rectal prolapse is presented.
NASA Technical Reports Server (NTRS)
Steinthorsson, E.; Modiano, David; Colella, Phillip
1994-01-01
A methodology for accurate and efficient simulation of unsteady, compressible flows is presented. The cornerstones of the methodology are a special discretization of the Navier-Stokes equations on structured body-fitted grid systems and an efficient solution-adaptive mesh refinement technique for structured grids. The discretization employs an explicit multidimensional upwind scheme for the inviscid fluxes and an implicit treatment of the viscous terms. The mesh refinement technique is based on the AMR algorithm of Berger and Colella. In this approach, cells on each level of refinement are organized into a small number of topologically rectangular blocks, each containing several thousand cells. The small number of blocks leads to small overhead in managing data, while their size and regular topology means that a high degree of optimization can be achieved on computers with vector processors.
Cerutti, Guillaume; Ali, Olivier; Godin, Christophe
2017-01-01
Context: The shoot apical meristem (SAM), origin of all aerial organs of the plant, is a restricted niche of stem cells whose growth is regulated by a complex network of genetic, hormonal and mechanical interactions. Studying the development of this area at cell level using 3D microscopy time-lapse imaging is a newly emerging key to understand the processes controlling plant morphogenesis. Computational models have been proposed to simulate those mechanisms, however their validation on real-life data is an essential step that requires an adequate representation of the growing tissue to be carried out. Achievements: The tool we introduce is a two-stage computational pipeline that generates a complete 3D triangular mesh of the tissue volume based on a segmented tissue image stack. DRACO (Dual Reconstruction by Adjacency Complex Optimization) is designed to retrieve the underlying 3D topological structure of the tissue and compute its dual geometry, while STEM (SAM Tissue Enhanced Mesh) returns a faithful triangular mesh optimized along several quality criteria (intrinsic quality, tissue reconstruction, visual adequacy). Quantitative evaluation tools measuring the performance of the method along those different dimensions are also provided. The resulting meshes can be used as input and validation for biomechanical simulations. Availability: DRACO-STEM is supplied as a package of the open-source multi-platform plant modeling library OpenAlea (http://openalea.github.io/) implemented in Python, and is freely distributed on GitHub (https://github.com/VirtualPlants/draco-stem) along with guidelines for installation and use. PMID:28424704
Complex torso reconstruction with human acellular dermal matrix: long-term clinical follow-up.
Nemeth, Nicole L; Butler, Charles E
2009-01-01
Although reports have demonstrated good early outcomes with human acellular dermal matrix even when used for complex, contaminated defects, no long-term outcomes have been reported. The authors reviewed the long-term outcomes of 13 patients who had complex torso reconstructions that included human acellular dermal matrix. All patients were at increased risk for mesh-related complications. Eight patients died as a result of progression of their oncologic disease at a mean of 258 days postoperatively. The mean follow-up for the remaining five patients was 43.7 months. Six patients had early complications (none were human acellular dermal matrix-related) and were reported on previously. Two patients had developed complications since the initial report. One patient developed a flap donor-site seroma remote from the reconstruction site, and another developed a recurrent ventral hernia. No patients have required additional surgery for human acellular dermal matrix-related complications. This follow-up report indicates that human acellular dermal matrix repair of large, complex torso defects can result in good long-term outcomes even when patients are at high risk for mesh-related complications.
Clinical outcomes after elective repair for small umbilical and epigastric hernias.
Christoffersen, Mette Maria Willaume
2015-11-01
Repair for an umbilical or epigastric hernia is one of the most frequently conducted gastrointestinal surgical procedures. Al-though it is a minor procedure, there is no consensus on the optimal repair technique. The readmission rate is surprisingly high due to postoperative pain, wound-related complications, and long-term results in terms of recurrence and chronic pain is not well investigated. The overall objective of this thesis was to improve early and long-term postoperative outcomes after repair for umbilical or epigastric hernias. The present thesis consisted of one RCT, one protocol article for a running RCT, and two register-based cohort studies. An abdominal binder had no analgesic effects or impact on seroma formation. We await early and late post-operative outcomes from a running RCT studying clinical effect of closing the hernia defect (inclusion is expected to end in October 2015). The two cohort studies included in the present theses found that mesh repair halved the long-term risk of recurrence compared with sutured repair. Mesh repair did not increase the risk of chronic pain or rate of reoperation for complications.
Disease model curation improvements at Mouse Genome Informatics
Bello, Susan M.; Richardson, Joel E.; Davis, Allan P.; Wiegers, Thomas C.; Mattingly, Carolyn J.; Dolan, Mary E.; Smith, Cynthia L.; Blake, Judith A.; Eppig, Janan T.
2012-01-01
Optimal curation of human diseases requires an ontology or structured vocabulary that contains terms familiar to end users, is robust enough to support multiple levels of annotation granularity, is limited to disease terms and is stable enough to avoid extensive reannotation following updates. At Mouse Genome Informatics (MGI), we currently use disease terms from Online Mendelian Inheritance in Man (OMIM) to curate mouse models of human disease. While OMIM provides highly detailed disease records that are familiar to many in the medical community, it lacks structure to support multilevel annotation. To improve disease annotation at MGI, we evaluated the merged Medical Subject Headings (MeSH) and OMIM disease vocabulary created by the Comparative Toxicogenomics Database (CTD) project. Overlaying MeSH onto OMIM provides hierarchical access to broad disease terms, a feature missing from the OMIM. We created an extended version of the vocabulary to meet the genetic disease-specific curation needs at MGI. Here we describe our evaluation of the CTD application, the extensions made by MGI and discuss the strengths and weaknesses of this approach. Database URL: http://www.informatics.jax.org/ PMID:22434831
Peng, Yufang; Bonifield, Gary; Smalheiser, Neil R.
2017-01-01
Within well-established fields of biomedical science, we identify “gaps”, topical areas of investigation that might be expected to occur but are missing. We define a field by carrying out a topical PubMed query, and analyze Medical Subject Headings by which the set of retrieved articles are indexed. Medical Subject headings (MeSH terms) which occur in >1% of the articles are examined pairwise to see how often they are predicted to co-occur within individual articles (assuming that they are independent of each other). A pair of MeSH terms that are predicted to co-occur in at least 10 articles, yet are not observed to co-occur in any article, are “gaps” and were studied further in a corpus of 10 disease-related article sets and 10 related to biological processes. Overall, articles that filled gaps were cited more heavily than non-gap-filling articles and were 61% more likely to be published in multidisciplinary high-impact journals. Nine different features of these “gaps” were characterized and tested to learn which, if any, correlate with the appearance of one or more articles containing both MeSH terms within the next five years. Several different types of gaps were identified, each having distinct combinations of predictive features: a) those arising as a byproduct of MeSH indexing rules; b) those having little biological meaning; c) those representing “low hanging fruit” for immediate exploitation; and d) those representing gaps across disciplines or sub-disciplines that do not talk to each other or work together. We have built a free, open tool called “Mine the Gap!” that identifies and characterizes the “gaps” for any PubMed query, which can be accessed via the Anne O’Tate value-added PubMed search interface (http://arrowsmith.psych.uic.edu/cgi-bin/arrowsmith_uic/AnneOTate.cgi). PMID:29271976
Irwin, Adriane N; Rackham, Daniel
Practicing evidence-based medicine requires health care professionals to efficiently retrieve relevant and current literature. The purpose of this study was to compare the time interval between PubMed entry and indexing with Medical Subject Headings (MeSH) between biomedical journals with varying impact factors, focus areas, and health care discipline representation. This was a cross-sectional study of articles entered into PubMed database between January 1 and December 31, 2012. The primary endpoint was the number of days between PubMed entry and indexing with MeSH terms. A total of 7906 articles were reviewed across 18 journals. In the first comparison, the time-to-indexing was 177 ± 100 days, 111 ± 69 days, and 23 ± 40 days for articles published in journals with impact factors of 2.0-2.5, 4.5-6.5, and >25, respectively (P ≤ 0.001). In the second comparison, the time-to-indexing was 111 ± 69 days for general medicine versus 170 ± 74 days for specialty journals (P ≤ 0.001). In the third comparison, the overall time-to-indexing was 177 ± 100 days, 234 ± 107 days, and 163 ± 58 days for medicine, nursing, and pharmacy journals, respectively (P ≤ 0.001). Study results identified a significant delay between entry of articles into the PubMed database and time-to-indexing with MeSH terms across journals of varying impact factor, discipline, and focus. Results suggest that there may be factors that influence the priority by which articles are indexed with MeSH terms. Future research should focus on determining those journal characteristics and any impact of this delay on clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Chacón, L.; Chen, G.; Barnes, D. C.
2013-01-01
We describe the extension of the recent charge- and energy-conserving one-dimensional electrostatic particle-in-cell algorithm in Ref. [G. Chen, L. Chacón, D.C. Barnes, An energy- and charge-conserving, implicit electrostatic particle-in-cell algorithm, Journal of Computational Physics 230 (2011) 7018-7036] to mapped (body-fitted) computational meshes. The approach maintains exact charge and energy conservation properties. Key to the algorithm is a hybrid push, where particle positions are updated in logical space, while velocities are updated in physical space. The effectiveness of the approach is demonstrated with a challenging numerical test case, the ion acoustic shock wave. The generalization of the approach to multiple dimensions is outlined.
Reconstruction of the anterior skull base after major trauma or extensive tumour resection.
König, Stefan Alexander; Ranguis, Sebastian; Gramlich, Veronika; Spetzger, Uwe
2015-01-01
The authors describe their experience with the reconstruction of complex anterior skull base defects after trauma or tumour resection using a "sandwich" technique with pericranial flap, titanium mesh and TachoSil. Description of surgical anatomy, surgical technique, indications, limitations, complications, specific perioperative considerations and specific information to give to the patient about surgery and potential risks. A summary of ten key points is given. After a bifrontal craniotomy and a subfrontal approach, it is possible to achieve a reliable reconstruction of the anterior skull base in a watertight manner by fixing a pericranial flap or a fascia lata graft to the orbital roofs and planum sphenoidale with an individually tailored titanium mesh and closing the frontobasal dura leasion with TachoSil.
Infectious encephalitis: Management without etiological diagnosis 48hours after onset.
Fillatre, P; Crabol, Y; Morand, P; Piroth, L; Honnorat, J; Stahl, J P; Lecuit, M
2017-05-01
The etiological diagnosis of infectious encephalitis is often not established 48hours after onset. We aimed to review existing literature data before providing management guidelines. We performed a literature search on PubMed using filters such as "since 01/01/2000", "human", "adults", "English or French", and "clinical trial/review/guidelines". We also used the Mesh search terms "encephalitis/therapy" and "encephalitis/diagnosis". With Mesh search terms "encephalitis/therapy" and "encephalitis/diagnosis", we retrieved 223 and 258 articles, respectively. With search terms "encephalitis and corticosteroid", we identified 38 articles, and with "encephalitis and doxycycline" without the above-mentioned filters we identified 85 articles. A total of 210 articles were included in the analysis. Etiological investigations must focus on recent travels, animal exposures, age, immunodeficiency, neurological damage characteristics, and potential extra-neurological signs. The interest of a diagnosis of encephalitis for which there is no specific treatment is also to discontinue any empirical treatments initially prescribed. Physicians must consider and search for autoimmune encephalitis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Clay, L; Stark, B; Gunnarsson, U; Strigård, K
2018-04-01
Repair of large incisional hernias includes the implantation of a synthetic mesh, but this may lead to pain, stiffness, infection and enterocutaneous fistulae. Autologous full-thickness skin graft as on-lay reinforcement has been tested in eight high-risk patients in a proof-of-concept study, with satisfactory results. In this multicenter randomized study, the use of skin graft was compared to synthetic mesh in giant ventral hernia repair. Non-smoking patients with a ventral hernia > 10 cm wide were randomized to repair using an on-lay autologous full-thickness skin graft or a synthetic mesh. The primary endpoint was surgical site complications during the first 3 months. A secondary endpoint was patient comfort. Fifty-three patients were included. Clinical evaluation was performed at a 3-month follow-up appointment. There were fewer patients in the skin graft group reporting discomfort: 3 (13%) vs. 12 (43%) (p = 0.016). Skin graft patients had less pain and a better general improvement. No difference was seen regarding seroma; 13 (54%) vs. 13 (46%), or subcutaneous wound infection; 5 (20%) vs. 7 (25%). One recurrence appeared in each group. Three patients in the skin graft group and two in the synthetic mesh group were admitted to the intensive care unit. No difference was seen for the primary endpoint short-term surgical complication. Full-thickness skin graft appears to be a reliable material for ventral hernia repair producing no more complications than when using synthetic mesh. Patients repaired with a skin graft have less subjective abdominal wall symptoms.
NASA Astrophysics Data System (ADS)
Nissen-Meyer, T.; Luo, Y.; Morency, C.; Tromp, J.
2008-12-01
Seismic-wave propagation in exploration-industry settings has seen major research and development efforts for decades, yet large-scale applications have often been limited to 2D or 3D finite-difference, (visco- )acoustic wave propagation due to computational limitations. We explore the possibility of including all relevant physical signatures in the wavefield using the spectral- element method (SPECFEM3D, SPECFEM2D), thereby accounting for acoustic, (visco-)elastic, poroelastic, anisotropic wave propagation in meshes which honor all crucial discontinuities. Mesh design is the crux of the problem, and we use CUBIT (Sandia Laboratories) to generate unstructured quadrilateral 2D and hexahedral 3D meshes for these complex background models. While general hexahedral mesh generation is an unresolved problem, we are able to accommodate most of the relevant settings (e.g., layer-cake models, salt bodies, overthrusting faults, and strong topography) with respectively tailored workflows. 2D simulations show localized, characteristic wave effects due to these features that shall be helpful in designing survey acquisition geometries in a relatively economic fashion. We address some of the fundamental issues this comprehensive modeling approach faces regarding its feasibility: Assessing geological structures in terms of the necessity to honor the major structural units, appropriate velocity model interpolation, quality control of the resultant mesh, and computational cost for realistic settings up to frequencies of 40 Hz. The solution to this forward problem forms the basis for subsequent 2D and 3D adjoint tomography within this context, which is the subject of a companion paper.
On wave breaking for Boussinesq-type models
NASA Astrophysics Data System (ADS)
Kazolea, M.; Ricchiuto, M.
2018-03-01
We consider the issue of wave breaking closure for Boussinesq type models, and attempt at providing some more understanding of the sensitivity of some closure approaches to the numerical set-up, and in particular to mesh size. For relatively classical choices of weakly dispersive propagation models, we compare two closure strategies. The first is the hybrid method consisting in suppressing the dispersive terms in breaking regions, as initially suggested by Tonelli and Petti in 2009. The second is an eddy viscosity approach based on the solution of a a turbulent kinetic energy. The formulation follows early work by O. Nwogu in the 90's, and some more recent developments by Zhang and co-workers (Ocean Mod. 2014), adapting it to be consistent with the wave breaking detection used here. We perform a study of the behaviour of the two closures for different mesh sizes, with attention to the possibility of obtaining grid independent results. Based on a classical shallow water theory, we also suggest some monitors to quantify the different contributions to the dissipation mechanism, differentiating those associated to the scheme from those of the partial differential equation. These quantities are used to analyze the dynamics of dissipation in some classical benchmarks, and its dependence on the mesh size. Our main results show that numerical dissipation contributes very little to the the results obtained when using eddy viscosity method. This closure shows little sensitivity to the grid, and may lend itself to the development and use of non-dissipative/energy conserving numerical methods. The opposite is observed for the hybrid approach, for which numerical dissipation plays a key role, and unfortunately is sensitive to the size of the mesh. In particular, when working, the two approaches investigated provide results which are in the same ball range and which agree with what is usually reported in literature. With the hybrid method, however, the inception of instabilities is observed at mesh sizes which vary from case to case, and depend on the propagation model. These results are comforted by numerical computations on a large number of classical benchmarks. To perform a systematic study of the behaviour of the two closures for different mesh sizes, with attention to the possibility of obtaining grid independent results, To gain an insight into the mechanism actually responsible for wave breaking by providing a quantitative description of the different contributions to the dissipation mechanism, differentiating those associated to the numerical scheme from those introduced at the PDE level, To provide some understanding of the sensitivity of the above mentioned dissipation to the mesh size, To prove the equivalent capabilities of the approaches studied in reproducing simple as well as complex wave transformation, while showing the substantial difference in the underlying dissipation mechanisms. The paper is organised as follows. Section two presents the two Boussinesq approximations used in this work. Section 3 discusses the numerical approximation of the models, as well as of the wave breaking closure. The comparison of the two approaches on a wide selection of benchmarks is discussed in Section 4. The paper is ended by a summary and a sketch of the future and ongoing developments of this work.
A recent advance in the automatic indexing of the biomedical literature.
Névéol, Aurélie; Shooshan, Sonya E; Humphrey, Susanne M; Mork, James G; Aronson, Alan R
2009-10-01
The volume of biomedical literature has experienced explosive growth in recent years. This is reflected in the corresponding increase in the size of MEDLINE, the largest bibliographic database of biomedical citations. Indexers at the US National Library of Medicine (NLM) need efficient tools to help them accommodate the ensuing workload. After reviewing issues in the automatic assignment of Medical Subject Headings (MeSH terms) to biomedical text, we focus more specifically on the new subheading attachment feature for NLM's Medical Text Indexer (MTI). Natural Language Processing, statistical, and machine learning methods of producing automatic MeSH main heading/subheading pair recommendations were assessed independently and combined. The best combination achieves 48% precision and 30% recall. After validation by NLM indexers, a suitable combination of the methods presented in this paper was integrated into MTI as a subheading attachment feature producing MeSH indexing recommendations compliant with current state-of-the-art indexing practice.
Valiant load-balanced robust routing under hose model for WDM mesh networks
NASA Astrophysics Data System (ADS)
Zhang, Xiaoning; Li, Lemin; Wang, Sheng
2006-09-01
In this paper, we propose Valiant Load-Balanced robust routing scheme for WDM mesh networks under the model of polyhedral uncertainty (i.e., hose model), and the proposed routing scheme is implemented with traffic grooming approach. Our Objective is to maximize the hose model throughput. A mathematic formulation of Valiant Load-Balanced robust routing is presented and three fast heuristic algorithms are also proposed. When implementing Valiant Load-Balanced robust routing scheme to WDM mesh networks, a novel traffic-grooming algorithm called MHF (minimizing hop first) is proposed. We compare the three heuristic algorithms with the VPN tree under the hose model. Finally we demonstrate in the simulation results that MHF with Valiant Load-Balanced robust routing scheme outperforms the traditional traffic-grooming algorithm in terms of the throughput for the uniform/non-uniform traffic matrix under the hose model.
NASA Astrophysics Data System (ADS)
Pantano, Carlos
2005-11-01
We describe a hybrid finite difference method for large-eddy simulation (LES) of compressible flows with a low-numerical dissipation scheme and structured adaptive mesh refinement (SAMR). Numerical experiments and validation calculations are presented including a turbulent jet and the strongly shock-driven mixing of a Richtmyer-Meshkov instability. The approach is a conservative flux-based SAMR formulation and as such, it utilizes refinement to computational advantage. The numerical method for the resolved scale terms encompasses the cases of scheme alternation and internal mesh interfaces resulting from SAMR. An explicit centered scheme that is consistent with a skew-symmetric finite difference formulation is used in turbulent flow regions while a weighted essentially non-oscillatory (WENO) scheme is employed to capture shocks. The subgrid stresses and transports are calculated by means of the streched-vortex model, Misra & Pullin (1997)
Parastomal hernia – current knowledge and treatment
Styliński, Roman; Rudzki, Sławomir
2018-01-01
Intestinal stoma creation is one of the most common surgical procedures. The most common long-term complication following stoma creation is parastomal hernia, which according to some authors is practically unavoidable. Statistical differences of its occurrence are mainly due to patient observation time and evaluation criteria. Consequently, primary prevention methods such as placement of prosthetic mesh and newly developed minimally invasive methods of stoma creation are used. It seems that in the light of evidence-based medicine, the best way to treat parastomal hernia is the one that the surgeon undertaking therapy is the most experienced in and is suited to the individuality of each patient, his condition and comorbidities. As a general rule, reinforcing the abdominal wall with a prosthetic mesh is the treatment of choice, with a low rate of complications and relapses over a long period of time. The current trend is to use lightweight, large pore meshes. PMID:29643952
Family medicine around the world: overview by region
Arya, Neil; Gibson, Christine; Ponka, David; Haq, Cynthia; Hansel, Stephanie; Dahlman, Bruce; Rouleau, Katherine
2017-01-01
Abstract Objective To demonstrate how family medicine has been recognized and integrated into primary health care systems in contrasting contexts around the world and to provide an overview of how family physicians are trained and certified. Composition of the committee Since 2012, the College of Family Physicians of Canada has hosted the Besrour Conferences to reflect on its role in advancing the discipline of family medicine globally. The Besrour Papers Working Group, which was struck at the 2013 conference, was tasked with developing a series of papers to highlight the key issues, lessons learned, and outcomes emerging from the various activities of the Besrour collaboration. The working group comprised members of various academic departments of family medicine in Canada and abroad who attended the conferences. Methods An initial search was conducted in PubMed using a family medicine hedge of MeSH terms, text words, and family medicine journals, combined with text words and terms representing low- and middle-income countries and the concept of family medicine training programs. A second search was completed using only family medicine terms in the CAB Direct and World Bank databases. Subsequent PubMed searches were conducted to identify articles about specific conditions or services based on suggestions from the authors of the articles selected from the second search. Additional articles were identified through reference lists of key articles and through Google searches. We then attempted to verify and augment the information through colleagues and partners. Report The scope of family medicine and the nature of family medicine training vary considerably worldwide. Challenges include limited capacity, incomplete understanding of roles, and variability of standards and recognition. Opportunities for advancement might include technology, collaboration, changes in pedagogy, flexible training methods, and system-wide support. PMID:28615392
Stone, Benjamin V; Forde, James C; Levit, Valerie B; Lee, Richard K; Te, Alexis E; Chughtai, Bilal
2016-11-01
In July 2011, the US Food and Drug Administration (FDA) issued a safety communication regarding serious complications associated with surgical mesh for pelvic organ prolapse, prompting increased media and public attention. This study sought to analyze internet search activity and news article volume after this FDA warning and to evaluate the quality of websites providing patient-centered information. Google Trends™ was utilized to evaluate search engine trends for the term "pelvic organ prolapse" and associated terms between 1 January 2004 and 31 December 2014. Google News™ was utilized to quantify the number of news articles annually under the term "pelvic organ prolapse." The search results for the term "pelvic organ prolapse" were assessed for quality using the Health On the Net Foundation (HON) certification. There was a significant increase in search activity from 37.42 in 2010 to 57.75 in 2011, at the time of the FDA communication (p = 0.021). No other annual interval had a statistically significant increase in search activity. The single highest monthly search activity, given the value of 100, was August 2011, immediately following the July 2011 notification, with the next highest value being 98 in July 2011. Linear regression analysis of news articles per year since the FDA communication revealed r 2 = 0.88, with a coefficient of 186. Quality assessment demonstrated that 42 % of websites were HON-certified, with .gov sites providing the highest quality information. Although the 2011 FDA safety communication on surgical mesh was associated with increased public and media attention, the quality of relevant health information on the internet remains of poor quality. Future quality assurance measures may be critical in enabling patients to play active roles in their own healthcare.
Mining the literature: new methods to exploit keyword profiles.
Andrade-Navarro, Miguel A
2012-01-01
Bibliographic records in the PubMed database of biomedical literature are annotated with Medical Subject Headings (MeSH) by curators, which summarize the content of the articles. Two recent publications explain how to generate profiles of MeSH terms for a set of bibliographic records and to use them to define any given concept by its associated literature. These concepts can then be related by their keyword profiles, and this can be used, for example, to detect new associations between genes and inherited diseases. http://www.biomedcentral.com/1471-2105/13/249/abstracthttp://genomemedicine.com/content/4/9/75/abstract.
NASA Astrophysics Data System (ADS)
Patel, Jitendra Kumar; Natarajan, Ganesh
2017-12-01
We discuss the development and assessment of a robust numerical algorithm for simulating multiphase flows with complex interfaces and high density ratios on arbitrary polygonal meshes. The algorithm combines the volume-of-fluid method with an incremental projection approach for incompressible multiphase flows in a novel hybrid staggered/non-staggered framework. The key principles that characterise the algorithm are the consistent treatment of discrete mass and momentum transport and the similar discretisation of force terms appearing in the momentum equation. The former is achieved by invoking identical schemes for convective transport of volume fraction and momentum in the respective discrete equations while the latter is realised by representing the gravity and surface tension terms as gradients of suitable scalars which are then discretised in identical fashion resulting in a balanced formulation. The hybrid staggered/non-staggered framework employed herein solves for the scalar normal momentum at the cell faces, while the volume fraction is computed at the cell centroids. This is shown to naturally lead to similar terms for pressure and its correction in the momentum and pressure correction equations respectively, which are again treated discretely in a similar manner. We show that spurious currents that corrupt the solution may arise both from an unbalanced formulation where forces (gravity and surface tension) are discretised in dissimilar manner and from an inconsistent approach where different schemes are used to convect the mass and momentum, with the latter prominent in flows which are convection-dominant with high density ratios. Interestingly, the inconsistent approach is shown to perform as well as the consistent approach even for high density ratio flows in some cases while it exhibits anomalous behaviour for other scenarios, even at low density ratios. Using a plethora of test problems of increasing complexity, we conclusively demonstrate that the consistent transport and balanced force treatment results in a numerically stable solution procedure and physically consistent results. The algorithm proposed in this study qualifies as a robust approach to simulate multiphase flows with high density ratios on unstructured meshes and may be realised in existing flow solvers with relative ease.
Multiphase flow modelling of explosive volcanic eruptions using adaptive unstructured meshes
NASA Astrophysics Data System (ADS)
Jacobs, Christian T.; Collins, Gareth S.; Piggott, Matthew D.; Kramer, Stephan C.
2014-05-01
Explosive volcanic eruptions generate highly energetic plumes of hot gas and ash particles that produce diagnostic deposits and pose an extreme environmental hazard. The formation, dispersion and collapse of these volcanic plumes are complex multiscale processes that are extremely challenging to simulate numerically. Accurate description of particle and droplet aggregation, movement and settling requires a model capable of capturing the dynamics on a range of scales (from cm to km) and a model that can correctly describe the important multiphase interactions that take place. However, even the most advanced models of eruption dynamics to date are restricted by the fixed mesh-based approaches that they employ. The research presented herein describes the development of a compressible multiphase flow model within Fluidity, a combined finite element / control volume computational fluid dynamics (CFD) code, for the study of explosive volcanic eruptions. Fluidity adopts a state-of-the-art adaptive unstructured mesh-based approach to discretise the domain and focus numerical resolution only in areas important to the dynamics, while decreasing resolution where it is not needed as a simulation progresses. This allows the accurate but economical representation of the flow dynamics throughout time, and potentially allows large multi-scale problems to become tractable in complex 3D domains. The multiphase flow model is verified with the method of manufactured solutions, and validated by simulating published gas-solid shock tube experiments and comparing the numerical results against pressure gauge data. The application of the model considers an idealised 7 km by 7 km domain in which the violent eruption of hot gas and volcanic ash high into the atmosphere is simulated. Although the simulations do not correspond to a particular eruption case study, the key flow features observed in a typical explosive eruption event are successfully captured. These include a shock wave resulting from the sudden high-velocity inflow of gas and ash; the formation of a particle-laden plume rising several hundred metres into the atmosphere; the eventual collapse of the plume which generates a volcanic ash fountain and a fast ground-hugging pyroclastic density current; and the growth of a dilute convective region that rises above the ash fountain as a result of buoyancy effects. The results from Fluidity are also compared with results from MFIX, a fixed structured mesh-based multiphase flow code, that uses the same set-up. The key flow features are also captured in MFIX, providing at least some confidence in the plausibility of the numerical results in the absence of quantitative field data. Finally, it is shown by a convergence analysis that Fluidity offers the same solution accuracy for reduced computational cost using an adaptive mesh, compared to the same simulation performed with a uniform fixed mesh.
Bioprosthetic tissue matrices in complex abdominal wall reconstruction.
Broyles, Justin M; Abt, Nicholas B; Sacks, Justin M; Butler, Charles E
2013-12-01
Complex abdominal defects are difficult problems encountered by surgeons in multiple specialties. Although current evidence supports the primary repair of these defects with mesh reinforcement, it is unclear which mesh is superior for any given clinical scenario. The purpose of this review was to explore the characteristics of and clinical relevance behind bioprosthetic tissue matrices in an effort to better clarify their role in abdominal wall reconstruction. We reviewed the peer-reviewed literature on the use of bioprosthetic mesh in human subjects. Basic science articles and large retrospective and prospective reviews were included in author's analysis. The clinical performance and characteristics of 13 bioprosthetic tissue matrices were evaluated. The majority of the products evaluated perform well in contaminated fields, where the risk of wound-healing difficulties is high. Clinical outcomes, which included infection, reherniation, and bulge formation, were variable, and the majority of the studies had a mean follow-up of less than 24 months. Although bioprosthetic matrix has a multitude of indications within the growing field of abdominal wall reconstruction, the functionality, regenerative capacity, and long-term fate of these products have yet to be fully established. Furthermore, the clinical performance, indications, and contraindications for each type of matrix need to be fully evaluated in long-term outcome studies.
Bioprosthetic Tissue Matrices in Complex Abdominal Wall Reconstruction
Broyles, Justin M.; Abt, Nicholas B.; Sacks, Justin M.
2013-01-01
Background: Complex abdominal defects are difficult problems encountered by surgeons in multiple specialties. Although current evidence supports the primary repair of these defects with mesh reinforcement, it is unclear which mesh is superior for any given clinical scenario. The purpose of this review was to explore the characteristics of and clinical relevance behind bioprosthetic tissue matrices in an effort to better clarify their role in abdominal wall reconstruction. Methods: We reviewed the peer-reviewed literature on the use of bioprosthetic mesh in human subjects. Basic science articles and large retrospective and prospective reviews were included in author’s analysis. The clinical performance and characteristics of 13 bioprosthetic tissue matrices were evaluated. Results: The majority of the products evaluated perform well in contaminated fields, where the risk of wound-healing difficulties is high. Clinical outcomes, which included infection, reherniation, and bulge formation, were variable, and the majority of the studies had a mean follow-up of less than 24 months. Conclusions: Although bioprosthetic matrix has a multitude of indications within the growing field of abdominal wall reconstruction, the functionality, regenerative capacity, and long-term fate of these products have yet to be fully established. Furthermore, the clinical performance, indications, and contraindications for each type of matrix need to be fully evaluated in long-term outcome studies. PMID:25289285
Laparoscopic hernia surgery: an overview.
Krähenbühl, L; Schäfer, M; Feodorovici, M A; Büchler, M W
1998-01-01
Despite the fact that laparoscopic hernia repair was already described in 1979, its value has still not been well defined. The standard treatment for uncomplicated primary hernia repair in Europe is an open anterior approach (i.e. Shouldice), and 'tension-free' mesh plug repair in the USA. At present, posterior mesh insertion is used to repair so-called complicated hernias with a complete myopectineal defect, and recurrent and bilateral hernias. Laparoscopic hernia repair (transabdominally and extraperitoneally) mimics this posterior mesh insertion and is therefore mostly used for treating complicated hernias. Whether or not a transabdominal or extraperitoneal approach is used depends on the type and size of the hernia, the risk to the patient, previous abdominal operations and the surgeon's experience. However, the extraperitoneal approach is now recommended because of its lower complication rate compared to the transabdominal approach. Compared to open surgical procedures the laparoscopic approach shows significant advantages in terms of less postoperative pain, decreased time off work and decreased overall costs. The disadvantages are increased operating time as well as difficulty in performing the procedure itself. A recent large randomized series has for the first time been able to demonstrate the advantages of the laparoscopic approach in a long-term follow-up. However, further studies are needed to define the exact place of laparoscopic hernia repair in the treatment of groin hernias.
Pelvic Organ Prolapse Repair with Mesh: Mid-Term Efficacy and Complications.
Mateu Arrom, Laura; Errando Smet, Carlos; Gutierrez Ruiz, Cristina; Araño, Pedro; Palou Redorta, Joan
2018-06-06
Our aim was to assess the efficacy and complications of pelvic organ prolapse (POP) correction with transvaginal mesh (TVM). We retrospectively assessed patients who had undergone a repair of an apical (primary or recurrent) or recurrent POP using TVM in our department since 2007. Meshes used were Prolift®, Elevate®, and Surelift®. Satisfaction with surgery was assessed on a 0-10 scale. A total of 83 patients were included (33 Prolift®, 36 Elevate®, 14 Surelift®), with a mean age of 67.8 ± 9.7 years. Eighteen (21.6%) patients underwent a recurrent POP correction. Follow-up was 49 ± 34 months. Twelve (14.4%) symptomatic recurrences were identified, 3 of which required further surgery. Satisfaction was 8.7. Four (4.8%) vaginal exposures were detected, 2 of which required partial mesh removal. Three (3.6%) cases of dyspareunia and 1 (1.2%) case of mild pelvic pain were reported, which did not require further treatment. The use of TVM for apical or recurrent POP repair is effective and is associated with a high satisfaction rate while complications are infrequent. © 2018 S. Karger AG, Basel.
Noh, Yeonsik; Bales, Justin R; Reyes, Bersain A; Molignano, Jennifer; Clement, Amanda L; Pins, George D; Florian, John P; Chon, Ki H
2016-08-01
In this study, we evaluated the performance of two novel conductive carbon black (CB) and polydimethlysiloxane (PDMS) bio-potential electrodes, with and without an integrated flexible copper mesh, against commercially available electrodes (Polar(®) textile, Silver-coated textile, and carbon rubber). The electrodes were tested in three types of water (fresh/unfiltered, chlorinated, and salt water). Our testing revealed that our CB/PDMS electrode with integrated copper mesh provided a high-fidelity ECG signal morphologies without any amplitude degradation in all of the types of water tested (N = 10). The non-meshed CB/PDMS electrodes were also subjected to a long-term durability test by the US Navy SCUBA divers during which the electrodes maintained ECG signal quality for a 6 h period of continuous use. The results of a material degradation analysis revealed the CB/PDMS composite material does not exhibit significant changes in physical integrity after prolonged exposure to the test conditions. The newly developed meshed CB/PDMS electrodes have the potential to be used in a wide variety of both dry and wet environments including the challenge of obtaining ECG signals in salt water environments.
Biocompatibility assessment of synthetic sling materials for female stress urinary incontinence.
Gomelsky, Alex; Dmochowski, Roger R
2007-10-01
We evaluated the performance and complications of currently available synthetic sling materials with a focus on in vitro and in vivo biocompatibility, and acceptance in the human body. We reviewed the MEDLINE database for relevant literature pertaining to various synthetic sling materials. The Food and Drug Administration regulations regarding the regulation and biocompatibility testing of synthetic meshes were also reviewed. Many synthetic meshes used for sling construction were introduced before rigorous Food and Drug Administration regulations were passed and, thus, some became associated with unique complications. Most meshes used in pubovaginal and mid urethral sling surgery are associated with high short-term success rates and relatively few intraoperative complications. Despite modifications and additives, slings constructed from polytetrafluoroethylene and polyethylene are poorly accepted by the human body. Flexible, macroporous, polypropylene meshes appear to integrate more completely with human tissue than other synthetic materials. However, multifilament and nonknitted polypropylene slings may integrate poorly. The composition, weave and pore size of each material are unique. These properties are responsible for the strength and durability of the material, as well as the ultimate acceptance and incorporation in the human body. Each material should be individually evaluated and patients should be counseled appropriately before implantation.
ISO Guest Observer Data Analysis and LWS Instrument Team Activities
NASA Technical Reports Server (NTRS)
Smith, Howard
2002-01-01
This project was granted a no-cost extension prompted by the request of the major subcontractor, the Naval Research Laboratory, which had not yet completed its tasks. As of July 2002, they had made substantial progress. They have successfully fabricated a metal mesh grid on polyimide, and also successfully fabricated a 2-layer metal mesh infrared filter using stacks of these metal mesh grids on polyimide; the actual layering was done at SAO. Both warm and cold spectroscopic tests were done on these fabricated devices. The measurements were in good agreement with the theory, and also reasonable performance in absolute terms. NRL is now working on fabricating a 3-layer metal mesh infrared filter, and a prototype is expected in the next month. Testing should occur before the end of the fiscal year. Finally, NRL has preliminarily agreed to hire a new postdoctoral person to refine the modeling of the filters based on the new measurements. The person should arrive this fall. NRL has a new Fourier Transform Spectrometer which will be delivered in the next month, and which will be used to facilitate the testing which has up to now been done in collaboration with NASA Goddard Space Flight Space Center.
Direct Replacement of Arbitrary Grid-Overlapping by Non-Structured Grid
NASA Technical Reports Server (NTRS)
Kao, Kai-Hsiung; Liou, Meng-Sing
1994-01-01
A new approach that uses nonstructured mesh to replace the arbitrarily overlapped structured regions of embedded grids is presented. The present methodology uses the Chimera composite overlapping mesh system so that the physical domain of the flowfield is subdivided into regions which can accommodate easily-generated grid for complex configuration. In addition, a Delaunay triangulation technique generates nonstructured triangular mesh which wraps over the interconnecting region of embedded grids. It is designed that the present approach, termed DRAGON grid, has three important advantages: eliminating some difficulties of the Chimera scheme, such as the orphan points and/or bad quality of interpolation stencils; making grid communication in a fully conservative way; and implementation into three dimensions is straightforward. A computer code based on a time accurate, finite volume, high resolution scheme for solving the compressible Navier-Stokes equations has been further developed to include both the Chimera overset grid and the nonstructured mesh schemes. For steady state problems, the local time stepping accelerates convergence based on a Courant - Friedrichs - Leury (CFL) number near the local stability limit. Numerical tests on representative steady and unsteady supersonic inviscid flows with strong shock waves are demonstrated.
A computational method for sharp interface advection.
Roenby, Johan; Bredmose, Henrik; Jasak, Hrvoje
2016-11-01
We devise a numerical method for passive advection of a surface, such as the interface between two incompressible fluids, across a computational mesh. The method is called isoAdvector, and is developed for general meshes consisting of arbitrary polyhedral cells. The algorithm is based on the volume of fluid (VOF) idea of calculating the volume of one of the fluids transported across the mesh faces during a time step. The novelty of the isoAdvector concept consists of two parts. First, we exploit an isosurface concept for modelling the interface inside cells in a geometric surface reconstruction step. Second, from the reconstructed surface, we model the motion of the face-interface intersection line for a general polygonal face to obtain the time evolution within a time step of the submerged face area. Integrating this submerged area over the time step leads to an accurate estimate for the total volume of fluid transported across the face. The method was tested on simple two-dimensional and three-dimensional interface advection problems on both structured and unstructured meshes. The results are very satisfactory in terms of volume conservation, boundedness, surface sharpness and efficiency. The isoAdvector method was implemented as an OpenFOAM ® extension and is published as open source.
van Iersel, Jan J; Paulides, Tim J C; Verheijen, Paul M; Lumley, John W; Broeders, Ivo A M J; Consten, Esther C J
2016-01-01
External and internal rectal prolapse with their affiliated rectocele and enterocele, are associated with debilitating symptoms such as obstructed defecation, pelvic pain and faecal incontinence. Since perineal procedures are associated with a higher recurrence rate, an abdominal approach is commonly preferred. Despite the description of greater than three hundred different procedures, thus far no clear superiority of one surgical technique has been demonstrated. Ventral mesh rectopexy (VMR) is a relatively new and promising technique to correct rectal prolapse. In contrast to the abdominal procedures of past decades, VMR avoids posterolateral rectal mobilisation and thereby minimizes the risk of postoperative constipation. Because of a perceived acceptable recurrence rate, good functional results and low mesh-related morbidity in the short to medium term, VMR has been popularized in the past decade. Laparoscopic or robotic-assisted VMR is now being progressively performed internationally and several articles and guidelines propose the procedure as the treatment of choice for rectal prolapse. In this article, an outline of the current status of laparoscopic and robotic ventral mesh rectopexy for the treatment of internal and external rectal prolapse is presented. PMID:27275090
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castelluccio, Gustavo M.; McDowell, David L.
The number of cycles required to form and grow microstructurally small fatigue cracks in metals exhibits substantial variability, particularly for low applied strain amplitudes. This variability is commonly attributed to the heterogeneity of cyclic plastic deformation within the microstructure, and presents a challenge to minimum life design of fatigue resistant components. Our paper analyzes sources of variability that contribute to the driving force of transgranular fatigue cracks within nucleant grains. We also employ crystal plasticity finite element simulations that explicitly render the polycrystalline microstructure and Fatigue Indicator Parameters (FIPs) averaged over different volume sizes and shapes relative to the anticipatedmore » fatigue damage process zone. Volume averaging is necessary to both achieve description of a finite fatigue damage process zone and to regularize mesh dependence in simulations. Furthermore, results from constant amplitude remote applied straining are characterized in terms of the extreme value distributions of volume averaged FIPs. Grain averaged FIP values effectively mitigate mesh sensitivity, but they smear out variability within grains. Furthermore, volume averaging over bands that encompass critical transgranular slip planes appear to present the most attractive approach to mitigate mesh sensitivity while preserving variability within grains.« less
Castelluccio, Gustavo M.; McDowell, David L.
2015-05-22
The number of cycles required to form and grow microstructurally small fatigue cracks in metals exhibits substantial variability, particularly for low applied strain amplitudes. This variability is commonly attributed to the heterogeneity of cyclic plastic deformation within the microstructure, and presents a challenge to minimum life design of fatigue resistant components. Our paper analyzes sources of variability that contribute to the driving force of transgranular fatigue cracks within nucleant grains. We also employ crystal plasticity finite element simulations that explicitly render the polycrystalline microstructure and Fatigue Indicator Parameters (FIPs) averaged over different volume sizes and shapes relative to the anticipatedmore » fatigue damage process zone. Volume averaging is necessary to both achieve description of a finite fatigue damage process zone and to regularize mesh dependence in simulations. Furthermore, results from constant amplitude remote applied straining are characterized in terms of the extreme value distributions of volume averaged FIPs. Grain averaged FIP values effectively mitigate mesh sensitivity, but they smear out variability within grains. Furthermore, volume averaging over bands that encompass critical transgranular slip planes appear to present the most attractive approach to mitigate mesh sensitivity while preserving variability within grains.« less
Recent advances in high-order WENO finite volume methods for compressible multiphase flows
NASA Astrophysics Data System (ADS)
Dumbser, Michael
2013-10-01
We present two new families of better than second order accurate Godunov-type finite volume methods for the solution of nonlinear hyperbolic partial differential equations with nonconservative products. One family is based on a high order Arbitrary-Lagrangian-Eulerian (ALE) formulation on moving meshes, which allows to resolve the material contact wave in a very sharp way when the mesh is moved at the speed of the material interface. The other family of methods is based on a high order Adaptive Mesh Refinement (AMR) strategy, where the mesh can be strongly refined in the vicinity of the material interface. Both classes of schemes have several building blocks in common, in particular: a high order WENO reconstruction operator to obtain high order of accuracy in space; the use of an element-local space-time Galerkin predictor step which evolves the reconstruction polynomials in time and that allows to reach high order of accuracy in time in one single step; the use of a path-conservative approach to treat the nonconservative terms of the PDE. We show applications of both methods to the Baer-Nunziato model for compressible multiphase flows.
Effects of mesh type on a non-premixed model in a flameless combustion simulation
NASA Astrophysics Data System (ADS)
Komonhirun, Seekharin; Yongyingsakthavorn, Pisit; Nontakeaw, Udomkiat
2018-01-01
Flameless combustion is a recently developed combustion system, which provides zero emission product. This phenomenon requires auto-ignition by supplying high-temperature air with low oxygen concentration. The flame is vanished and colorless. Temperature of the flameless combustion is less than that of a conventional case, where NOx reactions can be well suppressed. To design a flameless combustor, the computational fluid dynamics (CFD) is employed. The designed air-and-fuel injection method can be applied with the turbulent and non-premixed models. Due to the fact that nature of turbulent non-premixed combustion is based on molecular randomness, inappropriate mesh type can lead to significant numerical errors. Therefore, this research aims to numerically investigate the effects of mesh type on flameless combustion characteristics, which is a primary step of design process. Different meshes, i.e. tetrahedral, hexagonal are selected. Boundary conditions are 5% of oxygen and 900 K of air-inlet temperature for the flameless combustion, and 21% of oxygen and 300 K of air-inlet temperature for the conventional case. The results are finally presented and discussed in terms of velocity streamlines, and contours of turbulent kinetic energy and viscosity, temperature, and combustion products.
A point-centered arbitrary Lagrangian Eulerian hydrodynamic approach for tetrahedral meshes
Morgan, Nathaniel R.; Waltz, Jacob I.; Burton, Donald E.; ...
2015-02-24
We present a three dimensional (3D) arbitrary Lagrangian Eulerian (ALE) hydrodynamic scheme suitable for modeling complex compressible flows on tetrahedral meshes. The new approach stores the conserved variables (mass, momentum, and total energy) at the nodes of the mesh and solves the conservation equations on a control volume surrounding the point. This type of an approach is termed a point-centered hydrodynamic (PCH) method. The conservation equations are discretized using an edge-based finite element (FE) approach with linear basis functions. All fluxes in the new approach are calculated at the center of each tetrahedron. A multidirectional Riemann-like problem is solved atmore » the center of the tetrahedron. The advective fluxes are calculated by solving a 1D Riemann problem on each face of the nodal control volume. A 2-stage Runge–Kutta method is used to evolve the solution forward in time, where the advective fluxes are part of the temporal integration. The mesh velocity is smoothed by solving a Laplacian equation. The details of the new ALE hydrodynamic scheme are discussed. Results from a range of numerical test problems are presented.« less
NASA Astrophysics Data System (ADS)
Sheridan, M. F.; Stinton, A. J.; Patra, A.; Pitman, E. B.; Bauer, A.; Nichita, C. C.
2005-01-01
The Titan2D geophysical mass-flow model is evaluated by comparing its simulation results and those obtained from another flow model, FLOW3D, with published data on the 1963 Little Tahoma Peak avalanches on Mount Rainier, Washington. The avalanches, totaling approximately 10×10 6 m 3 of broken lava blocks and other debris, traveled 6.8 km horizontally and fell 1.8 km vertically ( H/ L=0.246). Velocities calculated from runup range from 24 to 42 m/s and may have been as high as 130 m/s while the avalanches passed over Emmons Glacier. Titan2D is a code for an incompressible Coulomb continuum; it is a depth-averaged, 'shallow-water', granular-flow model. The conservation equations for mass and momentum are solved with a Coulomb-type friction term at the basal interface. The governing equations are solved on multiple processors using a parallel, adaptive mesh, Godunov scheme. Adaptive gridding dynamically concentrates computing power in regions of special interest; mesh refinement and coarsening key on the perimeter of the moving avalanche. The model flow initiates as a pile defined as an ellipsoid by a height ( z) and an elliptical base defined by radii in the x and y planes. Flow parameters are the internal friction angle and bed friction angle. Results from the model are similar in terms of velocity history, lateral spreading, location of runup areas, and final distribution of the Little Tahoma Peak deposit. The avalanches passed over the Emmons Glacier along their upper flow paths, but lower in the valley they traversed stream gravels and glacial outwash deposits. This presents difficulty in assigning an appropriate bed friction angle for the entire deposit. Incorporation of variable bed friction angles into the model using GIS will help to resolve this issue.
NASA Astrophysics Data System (ADS)
Lee, Chin Yik; Cant, Stewart
2017-07-01
A premixed propane-air flame stabilised on a triangular bluff body in a model jet-engine afterburner configuration is investigated using large-eddy simulation (LES). The reaction rate source term for turbulent premixed combustion is closed using the transported flame surface density (TFSD) model. In this approach, there is no need to assume local equilibrium between the generation and destruction of subgrid FSD, as commonly done in simple algebraic closure models. Instead, the key processes that create and destroy FSD are accounted for explicitly. This allows the model to capture large-scale unsteady flame propagation in the presence of combustion instabilities, or in situations where the flame encounters progressive wrinkling with time. In this study, comprehensive validation of the numerical method is carried out. For the non-reacting flow, good agreement for both the time-averaged and root-mean-square velocity fields are obtained, and the Karman type vortex shedding behaviour seen in the experiment is well represented. For the reacting flow, two mesh configurations are used to investigate the sensitivity of the LES results to the numerical resolution. Profiles for the velocity and temperature fields exhibit good agreement with the experimental data for both the coarse and dense mesh. This demonstrates the capability of LES coupled with the TFSD approach in representing the highly unsteady premixed combustion observed in this configuration. The instantaneous flow pattern and turbulent flame behaviour are discussed, and the differences between the non-reacting and reacting flow are described through visualisation of vortical structures and their interaction with the flame. Lastly, the generation and destruction of FSD are evaluated by examining the individual terms in the FSD transport equation. Localised regions where straining, curvature and propagation are each dominant are observed, highlighting the importance of non-equilibrium effects of FSD generation and destruction in the model afterburner.
Smalheiser, Neil R; McDonagh, Marian S; Yu, Clement; Adams, Clive E; Davis, John M; Yu, Philip S
2015-01-01
Objective: For many literature review tasks, including systematic review (SR) and other aspects of evidence-based medicine, it is important to know whether an article describes a randomized controlled trial (RCT). Current manual annotation is not complete or flexible enough for the SR process. In this work, highly accurate machine learning predictive models were built that include confidence predictions of whether an article is an RCT. Materials and Methods: The LibSVM classifier was used with forward selection of potential feature sets on a large human-related subset of MEDLINE to create a classification model requiring only the citation, abstract, and MeSH terms for each article. Results: The model achieved an area under the receiver operating characteristic curve of 0.973 and mean squared error of 0.013 on the held out year 2011 data. Accurate confidence estimates were confirmed on a manually reviewed set of test articles. A second model not requiring MeSH terms was also created, and performs almost as well. Discussion: Both models accurately rank and predict article RCT confidence. Using the model and the manually reviewed samples, it is estimated that about 8000 (3%) additional RCTs can be identified in MEDLINE, and that 5% of articles tagged as RCTs in Medline may not be identified. Conclusion: Retagging human-related studies with a continuously valued RCT confidence is potentially more useful for article ranking and review than a simple yes/no prediction. The automated RCT tagging tool should offer significant savings of time and effort during the process of writing SRs, and is a key component of a multistep text mining pipeline that we are building to streamline SR workflow. In addition, the model may be useful for identifying errors in MEDLINE publication types. The RCT confidence predictions described here have been made available to users as a web service with a user query form front end at: http://arrowsmith.psych.uic.edu/cgi-bin/arrowsmith_uic/RCT_Tagger.cgi. PMID:25656516
Selection of finite-element mesh parameters in modeling the growth of hydraulic fracturing cracks
NASA Astrophysics Data System (ADS)
Kurguzov, V. D.
2016-12-01
The effect of the mesh geometry on the accuracy of solutions obtained by the finite-element method for problems of linear fracture mechanics is investigated. The guidelines have been formulated for constructing an optimum mesh for several routine problems involving elements with linear and quadratic approximation of displacements. The accuracy of finite-element solutions is estimated based on the degree of the difference between the calculated stress-intensity factor (SIF) and its value obtained analytically. In problems of hydrofracturing of oil-bearing formation, the pump-in pressure of injected water produces a distributed load on crack flanks as opposed to standard fracture mechanics problems that have analytical solutions, where a load is applied to the external boundaries of the computational region and the cracks themselves are kept free from stresses. Some model pressure profiles, as well as pressure profiles taken from real hydrodynamic computations, have been considered. Computer models of cracks with allowance for the pre-stressed state, fracture toughness, and elastic properties of materials are developed in the MSC.Marc 2012 finite-element analysis software. The Irwin force criterion is used as a criterion of brittle fracture and the SIFs are computed using the Cherepanov-Rice invariant J-integral. The process of crack propagation in a linearly elastic isotropic body is described in terms of the elastic energy release rate G and modeled using the VCCT (Virtual Crack Closure Technique) approach. It has been found that the solution accuracy is sensitive to the mesh configuration. Several parameters that are decisive in constructing effective finite-element meshes, namely, the minimum element size, the distance between mesh nodes in the vicinity of a crack tip, and the ratio of the height of an element to its length, have been established. It has been shown that a mesh that consists of only small elements does not improve the accuracy of the solution.
Olmi, Stefano; Scaini, Alberto; Erba, Luigi; Bertolini, Aimone; Croce, Enrico
2007-11-01
Laparoscopic repair of inguinal hernias is usually achieved by totally extraperitoneal (TEP) or transabdominal preperitoneal (TAPP) techniques. The intraperitoneal onlay mesh (IPOM) could be an interesting alternative as it is much easier to perform and faster to execute. This technique is subject to correct selection of indications and to demonstration of its safety. From January 2003 to January 2006 we performed 61 laparoscopic hernia procedures on 60 selected patients (60 males with a mean age of 60 and mean weight of 76 kg) with an IPOM technique combining the Parietex composite mesh (12 cm circular model) and a fibrin glue (Tissucol) for its fixation. The glue was diluted to increase fixation time and applied to the mesh prior to positioning on the hernia defect. Mean operative time was 10 minutes. Mean hernia diameter was 2.5 cm (+/- 0.8 cm). 10 hernias were direct, 51 were indirect and 10 out of 61 were recurrent. We did not convert any of the laparoscopic procedures. Mean hospital stay was one day; mean recovery time for working and general physical activities was five days. Patients were checked after one week, 1-3-6 months and 1-2 years. Average follow up time was 23.7 months. 1.6 % of patients showed short-term complications: one trocar site haematoma. No additional complications were reported; particularly, we had no recurrence, no seroma, no mesh migration, and no bowel obstruction or fistula. Results of this study show intraperitoneal (IP) tolerance to this kind of mesh and the safety of its fixation with Tissucol. The absence of recurrence and complications could be a good reason to extend the indication of IPOM hernia repair. However, these preliminary results should be confirmed by longer follow-up.
A Godunov-like point-centered essentially Lagrangian hydrodynamic approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, Nathaniel R.; Waltz, Jacob I.; Burton, Donald E.
We present an essentially Lagrangian hydrodynamic scheme suitable for modeling complex compressible flows on tetrahedron meshes. The scheme reduces to a purely Lagrangian approach when the flow is linear or if the mesh size is equal to zero; as a result, we use the term essentially Lagrangian for the proposed approach. The motivation for developing a hydrodynamic method for tetrahedron meshes is because tetrahedron meshes have some advantages over other mesh topologies. Notable advantages include reduced complexity in generating conformal meshes, reduced complexity in mesh reconnection, and preserving tetrahedron cells with automatic mesh refinement. A challenge, however, is tetrahedron meshesmore » do not correctly deform with a lower order (i.e. piecewise constant) staggered-grid hydrodynamic scheme (SGH) or with a cell-centered hydrodynamic (CCH) scheme. The SGH and CCH approaches calculate the strain via the tetrahedron, which can cause artificial stiffness on large deformation problems. To resolve the stiffness problem, we adopt the point-centered hydrodynamic approach (PCH) and calculate the evolution of the flow via an integration path around the node. The PCH approach stores the conserved variables (mass, momentum, and total energy) at the node. The evolution equations for momentum and total energy are discretized using an edge-based finite element (FE) approach with linear basis functions. A multidirectional Riemann-like problem is introduced at the center of the tetrahedron to account for discontinuities in the flow such as a shock. Conservation is enforced at each tetrahedron center. The multidimensional Riemann-like problem used here is based on Lagrangian CCH work [8, 19, 37, 38, 44] and recent Lagrangian SGH work [33-35, 39, 45]. In addition, an approximate 1D Riemann problem is solved on each face of the nodal control volume to advect mass, momentum, and total energy. The 1D Riemann problem produces fluxes [18] that remove a volume error in the PCH discretization. A 2-stage Runge–Kutta method is used to evolve the solution in time. The details of the new hydrodynamic scheme are discussed; likewise, results from numerical test problems are presented.« less
A Godunov-like point-centered essentially Lagrangian hydrodynamic approach
Morgan, Nathaniel R.; Waltz, Jacob I.; Burton, Donald E.; ...
2014-10-28
We present an essentially Lagrangian hydrodynamic scheme suitable for modeling complex compressible flows on tetrahedron meshes. The scheme reduces to a purely Lagrangian approach when the flow is linear or if the mesh size is equal to zero; as a result, we use the term essentially Lagrangian for the proposed approach. The motivation for developing a hydrodynamic method for tetrahedron meshes is because tetrahedron meshes have some advantages over other mesh topologies. Notable advantages include reduced complexity in generating conformal meshes, reduced complexity in mesh reconnection, and preserving tetrahedron cells with automatic mesh refinement. A challenge, however, is tetrahedron meshesmore » do not correctly deform with a lower order (i.e. piecewise constant) staggered-grid hydrodynamic scheme (SGH) or with a cell-centered hydrodynamic (CCH) scheme. The SGH and CCH approaches calculate the strain via the tetrahedron, which can cause artificial stiffness on large deformation problems. To resolve the stiffness problem, we adopt the point-centered hydrodynamic approach (PCH) and calculate the evolution of the flow via an integration path around the node. The PCH approach stores the conserved variables (mass, momentum, and total energy) at the node. The evolution equations for momentum and total energy are discretized using an edge-based finite element (FE) approach with linear basis functions. A multidirectional Riemann-like problem is introduced at the center of the tetrahedron to account for discontinuities in the flow such as a shock. Conservation is enforced at each tetrahedron center. The multidimensional Riemann-like problem used here is based on Lagrangian CCH work [8, 19, 37, 38, 44] and recent Lagrangian SGH work [33-35, 39, 45]. In addition, an approximate 1D Riemann problem is solved on each face of the nodal control volume to advect mass, momentum, and total energy. The 1D Riemann problem produces fluxes [18] that remove a volume error in the PCH discretization. A 2-stage Runge–Kutta method is used to evolve the solution in time. The details of the new hydrodynamic scheme are discussed; likewise, results from numerical test problems are presented.« less
Synchronistic mind-matter correlations in therapeutic practice: a commentary on Connolly (2015).
Atmanspacher, Harald; Fach, Wolfgang
2016-02-01
This commentary adds some ideas and refinements to the inspiring discussion in a recent paper by Connolly () that makes use of a dual-aspect framework developed by us earlier. One key point is that exceptional experiences (of which synchronicities are a special case) cannot in general be identified with experiences of non-categorial or acategorial mental states. In fact, most exceptional experiences reported in the literature are experiences of categorial states. Conversely, there are non-categorial and acategorial states whose experience is not exceptional. Moreover, the psychodynamics of a synchronistic experience contain a subtle mesh of interacting processes pertaining to categorial, non-categorial and acategorial domains. We outline how this mesh may be addressed in particular cases of synchronicity described by Connolly. © 2016, The Society of Analytical Psychology.
New concept single screw compressors and their manufacture technology
NASA Astrophysics Data System (ADS)
Feng, Q.; Liu, F.; Chang, L.; Feng, C.; Peng, C.; Xie, J.; van den Broek, M.
2017-08-01
Single screw compressors were generally acknowledged as one of the nearly perfect machines by compressor researchers and manufacturers. However the rapid wear of the star-wheel in a single screw compressor during operation is a key reason why it hasn’t previously joined the main current compressors’ market. After more than ten years of effective work, the authors of this paper have proposed a new concept single screw compressor whose mesh-couple profile is enveloped with multi-column. Also a new design method and manufacture equipment for this kind of compressor have been developed and are described in this paper. A lot of prototype tests and a long period of industrial operations under full loading conditions have shown that the mesh-couple profiles of the new concept single compressors have excellent anti-wearness.
Topological numbering of features on a mesh
NASA Technical Reports Server (NTRS)
Atallah, Mikhail J.; Hambrusch, Susanne E.; Tewinkel, Lynn E.
1988-01-01
Assume a nxn binary image is given containing horizontally convex features; i.e., for each feature, each of its row's pixels form an interval on that row. The problem of assigning topological numbers to such features is considered; i.e., assign a number to every feature f so that all features to the left of f have a smaller number assigned to them. This problem arises in solutions to the stereo matching problem. A parallel algorithm to solve the topological numbering problem in O(n) time on an nxn mesh of processors is presented. The key idea of the solution is to create a tree from which the topological numbers can be obtained even though the tree does not uniquely represent the to the left of relationship of the features.
3D active shape models of human brain structures: application to patient-specific mesh generation
NASA Astrophysics Data System (ADS)
Ravikumar, Nishant; Castro-Mateos, Isaac; Pozo, Jose M.; Frangi, Alejandro F.; Taylor, Zeike A.
2015-03-01
The use of biomechanics-based numerical simulations has attracted growing interest in recent years for computer-aided diagnosis and treatment planning. With this in mind, a method for automatic mesh generation of brain structures of interest, using statistical models of shape (SSM) and appearance (SAM), for personalised computational modelling is presented. SSMs are constructed as point distribution models (PDMs) while SAMs are trained using intensity profiles sampled from a training set of T1-weighted magnetic resonance images. The brain structures of interest are, the cortical surface (cerebrum, cerebellum & brainstem), lateral ventricles and falx-cerebri membrane. Two methods for establishing correspondences across the training set of shapes are investigated and compared (based on SSM quality): the Coherent Point Drift (CPD) point-set registration method and B-spline mesh-to-mesh registration method. The MNI-305 (Montreal Neurological Institute) average brain atlas is used to generate the template mesh, which is deformed and registered to each training case, to establish correspondence over the training set of shapes. 18 healthy patients' T1-weightedMRimages form the training set used to generate the SSM and SAM. Both model-training and model-fitting are performed over multiple brain structures simultaneously. Compactness and generalisation errors of the BSpline-SSM and CPD-SSM are evaluated and used to quantitatively compare the SSMs. Leave-one-out cross validation is used to evaluate SSM quality in terms of these measures. The mesh-based SSM is found to generalise better and is more compact, relative to the CPD-based SSM. Quality of the best-fit model instance from the trained SSMs, to test cases are evaluated using the Hausdorff distance (HD) and mean absolute surface distance (MASD) metrics.
A new design concept for knitted external vein-graft support mesh.
Singh, Charanpreet; Wang, Xungai
2015-08-01
Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights reserved.
A new class of accurate, mesh-free hydrodynamic simulation methods
NASA Astrophysics Data System (ADS)
Hopkins, Philip F.
2015-06-01
We present two new Lagrangian methods for hydrodynamics, in a systematic comparison with moving-mesh, smoothed particle hydrodynamics (SPH), and stationary (non-moving) grid methods. The new methods are designed to simultaneously capture advantages of both SPH and grid-based/adaptive mesh refinement (AMR) schemes. They are based on a kernel discretization of the volume coupled to a high-order matrix gradient estimator and a Riemann solver acting over the volume `overlap'. We implement and test a parallel, second-order version of the method with self-gravity and cosmological integration, in the code GIZMO:1 this maintains exact mass, energy and momentum conservation; exhibits superior angular momentum conservation compared to all other methods we study; does not require `artificial diffusion' terms; and allows the fluid elements to move with the flow, so resolution is automatically adaptive. We consider a large suite of test problems, and find that on all problems the new methods appear competitive with moving-mesh schemes, with some advantages (particularly in angular momentum conservation), at the cost of enhanced noise. The new methods have many advantages versus SPH: proper convergence, good capturing of fluid-mixing instabilities, dramatically reduced `particle noise' and numerical viscosity, more accurate sub-sonic flow evolution, and sharp shock-capturing. Advantages versus non-moving meshes include: automatic adaptivity, dramatically reduced advection errors and numerical overmixing, velocity-independent errors, accurate coupling to gravity, good angular momentum conservation and elimination of `grid alignment' effects. We can, for example, follow hundreds of orbits of gaseous discs, while AMR and SPH methods break down in a few orbits. However, fixed meshes minimize `grid noise'. These differences are important for a range of astrophysical problems.
NASA Astrophysics Data System (ADS)
Blöcher, Johanna; Kuraz, Michal
2017-04-01
In this contribution we propose implementations of the dual permeability model with different inter-domain exchange descriptions and metaheuristic optimization algorithms for parameter identification and mesh optimization. We compare variants of the coupling term with different numbers of parameters to test if a reduction of parameters is feasible. This can reduce parameter uncertainty in inverse modeling, but also allow for different conceptual models of the domain and matrix coupling. The different variants of the dual permeability model are implemented in the open-source objective library DRUtES written in FORTRAN 2003/2008 in 1D and 2D. For parameter identification we use adaptations of the particle swarm optimization (PSO) and Teaching-learning-based optimization (TLBO), which are population-based metaheuristics with different learning strategies. These are high-level stochastic-based search algorithms that don't require gradient information or a convex search space. Despite increasing computing power and parallel processing, an overly fine mesh is not feasible for parameter identification. This creates the need to find a mesh that optimizes both accuracy and simulation time. We use a bi-objective PSO algorithm to generate a Pareto front of optimal meshes to account for both objectives. The dual permeability model and the optimization algorithms were tested on virtual data and field TDR sensor readings. The TDR sensor readings showed a very steep increase during rapid rainfall events and a subsequent steep decrease. This was theorized to be an effect of artificial macroporous envelopes surrounding TDR sensors creating an anomalous region with distinct local soil hydraulic properties. One of our objectives is to test how well the dual permeability model can describe this infiltration behavior and what coupling term would be most suitable.
An assessment of the visibility of MeSH-indexed medical web catalogs through search engines.
Zweigenbaum, P; Darmoni, S J; Grabar, N; Douyère, M; Benichou, J
2002-01-01
Manually indexed Internet health catalogs such as CliniWeb or CISMeF provide resources for retrieving high-quality health information. Users of these quality-controlled subject gateways are most often referred to them by general search engines such as Google, AltaVista, etc. This raises several questions, among which the following: what is the relative visibility of medical Internet catalogs through search engines? This study addresses this issue by measuring and comparing the visibility of six major, MeSH-indexed health catalogs through four different search engines (AltaVista, Google, Lycos, Northern Light) in two languages (English and French). Over half a million queries were sent to the search engines; for most of these search engines, according to our measures at the time the queries were sent, the most visible catalog for English MeSH terms was CliniWeb and the most visible one for French MeSH terms was CISMeF.
Molecular Dynamics Simulations of Carbon Nanotubes in Water
NASA Technical Reports Server (NTRS)
Walther, J. H.; Jaffe, R.; Halicioglu, T.; Koumoutsakos, P.
2000-01-01
We study the hydrophobic/hydrophilic behavior of carbon nanotubes using molecular dynamics simulations. The energetics of the carbon-water interface are mainly dispersive but in the present study augmented with a carbon quadrupole term acting on the charge sites of the water. The simulations indicate that this contribution is negligible in terms of modifying the structural properties of water at the interface. Simulations of two carbon nanotubes in water display a wetting and drying of the interface between the nanotubes depending on their initial spacing. Thus, initial tube spacings of 7 and 8 A resulted in a drying of the interface whereas spacing of > 9 A remain wet during the course of the simulation. Finally, we present a novel particle-particle-particle-mesh algorithm for long range potentials which allows for general (curvilinear) meshes and "black-box" fast solvers by adopting an influence matrix technique.
Efficient Management of Certificate Revocation Lists in Smart Grid Advanced Metering Infrastructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cebe, Mumin; Akkaya, Kemal
Advanced Metering Infrastructure (AMI) forms a communication network for the collection of power data from smart meters in Smart Grid. As the communication within an AMI needs to be secure, key management becomes an issue due to overhead and limited resources. While using public-keys eliminate some of the overhead of key management, there is still challenges regarding certificates that store and certify the publickeys. In particular, distribution and storage of certificate revocation list (CRL) is major a challenge due to cost of distribution and storage in AMI networks which typically consist of wireless multi-hop networks. Motivated by the need ofmore » keeping the CRL distribution and storage cost effective and scalable, in this paper, we present a distributed CRL management model utilizing the idea of distributed hash trees (DHTs) from peer-to-peer (P2P) networks. The basic idea is to share the burden of storage of CRLs among all the smart meters by exploiting the meshing capability of the smart meters among each other. Thus, using DHTs not only reduces the space requirements for CRLs but also makes the CRL updates more convenient. We implemented this structure on ns-3 using IEEE 802.11s mesh standard as a model for AMI and demonstrated its superior performance with respect to traditional methods of CRL management through extensive simulations.« less
Effects of trawl selectivity and genetic parameters on fish body length under long-term trawling
NASA Astrophysics Data System (ADS)
Yu, Yang; Sun, Peng; Cui, He; Sheng, Huaxiang; Zhao, Fenfang; Tang, Yanli; Chen, Zelin
2015-10-01
Long-term fishing pressure affects the biological characteristics of exploited fish stocks. The biological characteristics of hairtail ( Trichiurus lepturus) in the East China Sea are unable to recover because of long-term trawling. Fishing induces evolutionary effects on the fish's biological characteristics. Evidence of these changes includes small size at age, a shift to earlier age structure, and early maturation. Natural and artificial selection usually affect the fish's life history. Selection can induce different chances of reproduction, and individual fish can give a different genetic contribution to the next generation. In this study, analysis of time-dependent probability of significance and test of sensitivity were used to explore the effects of fish exploitation rate, mesh size, and heritability with long-term trawling. Results showed that fishing parameters were important drivers to exploited fish population. However, genetic traits altered by fishing were slow, and the changes in biological characteristics were weaker than those caused by fishing selection. Exploitation rate and mesh size exhibited similar evolutionary trend tendency under long-term fishing. The time-dependent probability of significance trend showed a gradual growth and tended to be stable. Therefore, the direction of fishing-induced evolution and successful management of fish species require considerable attention to contribute to sustainable fisheries in China.
Retrieval feedback in MEDLINE.
Srinivasan, P
1996-01-01
OBJECTIVE: To investigate a new approach for query expansion based on retrieval feedback. The first objective in this study was to examine alternative query-expansion methods within the same retrieval-feedback framework. The three alternatives proposed are: expansion on the MeSH query field alone, expansion on the free-text field alone, and expansion on both the MeSH and the free-text fields. The second objective was to gain further understanding of retrieval feedback by examining possible dependencies on relevant documents during the feedback cycle. DESIGN: Comparative study of retrieval effectiveness using the original unexpanded and the alternative expanded user queries on a MEDLINE test collection of 75 queries and 2,334 MEDLINE citations. MEASUREMENTS: Retrieval effectivenesses of the original unexpanded and the alternative expanded queries were compared using 11-point-average precision scores (11-AvgP). These are averages of precision scores obtained at 11 standard recall points. RESULTS: All three expansion strategies significantly improved the original queries in terms of retrieval effectiveness. Expansion on MeSH alone was equivalent to expansion on both MeSH and the free-text fields. Expansion on the free-text field alone improved the queries significantly less than did the other two strategies. The second part of the study indicated that retrieval-feedback-based expansion yields significant performance improvements independent of the availability of relevant documents for feedback information. CONCLUSIONS: Retrieval feedback offers a robust procedure for query expansion that is most effective for MEDLINE when applied to the MeSH field. PMID:8653452
Zhao, S; Li, S J; Hou, W T; Hao, Y L; Yang, R; Misra, R D K
2016-06-01
Additive manufacturing technique is a promising approach for fabricating cellular bone substitutes such as trabecular and cortical bones because of the ability to adjust process parameters to fabricate different shapes and inner structures. Considering the long term safe application in human body, the metallic cellular implants are expected to exhibit superior fatigue property. The objective of the study was to study the influence of cell shape on the compressive fatigue behavior of Ti-6Al-4V mesh arrays fabricated by electron beam melting. The results indicated that the underlying fatigue mechanism for the three kinds of meshes (cubic, G7 and rhombic dodecahedron) is the interaction of cyclic ratcheting and fatigue crack growth on the struts, which is closely related to cumulative effect of buckling and bending deformation of the strut. By increasing the buckling deformation on the struts through cell shape design, the cyclic ratcheting rate of the meshes during cyclic deformation was decreased and accordingly, the compressive fatigue strength was increased. With increasing bending deformation of struts, fatigue crack growth in struts contributed more to the fatigue damage of meshes. Rough surface and pores contained in the struts significantly deteriorated the compressive fatigue strength of the struts. By optimizing the buckling and bending deformation through cell shape design, Ti-6Al-4V alloy cellular solids with high fatigue strength and low modulus can be fabricated by the EBM technique. Copyright © 2016 Elsevier Ltd. All rights reserved.
Heidenreich, Elvio A; Ferrero, José M; Doblaré, Manuel; Rodríguez, José F
2010-07-01
Many problems in biology and engineering are governed by anisotropic reaction-diffusion equations with a very rapidly varying reaction term. This usually implies the use of very fine meshes and small time steps in order to accurately capture the propagating wave while avoiding the appearance of spurious oscillations in the wave front. This work develops a family of macro finite elements amenable for solving anisotropic reaction-diffusion equations with stiff reactive terms. The developed elements are incorporated on a semi-implicit algorithm based on operator splitting that includes adaptive time stepping for handling the stiff reactive term. A linear system is solved on each time step to update the transmembrane potential, whereas the remaining ordinary differential equations are solved uncoupled. The method allows solving the linear system on a coarser mesh thanks to the static condensation of the internal degrees of freedom (DOF) of the macroelements while maintaining the accuracy of the finer mesh. The method and algorithm have been implemented in parallel. The accuracy of the method has been tested on two- and three-dimensional examples demonstrating excellent behavior when compared to standard linear elements. The better performance and scalability of different macro finite elements against standard finite elements have been demonstrated in the simulation of a human heart and a heterogeneous two-dimensional problem with reentrant activity. Results have shown a reduction of up to four times in computational cost for the macro finite elements with respect to equivalent (same number of DOF) standard linear finite elements as well as good scalability properties.
NASA Astrophysics Data System (ADS)
Salvalaglio, Marco; Backofen, Rainer; Voigt, Axel; Elder, Ken R.
2017-08-01
One of the major difficulties in employing phase-field crystal (PFC) modeling and the associated amplitude (APFC) formulation is the ability to tune model parameters to match experimental quantities. In this work, we address the problem of tuning the defect core and interface energies in the APFC formulation. We show that the addition of a single term to the free-energy functional can be used to increase the solid-liquid interface and defect energies in a well-controlled fashion, without any major change to other features. The influence of the newly added term is explored in two-dimensional triangular and honeycomb structures as well as bcc and fcc lattices in three dimensions. In addition, a finite-element method (FEM) is developed for the model that incorporates a mesh refinement scheme. The combination of the FEM and mesh refinement to simulate amplitude expansion with a new energy term provides a method of controlling microscopic features such as defect and interface energies while simultaneously delivering a coarse-grained examination of the system.
Multicasting in Wireless Communications (Ad-Hoc Networks): Comparison against a Tree-Based Approach
NASA Astrophysics Data System (ADS)
Rizos, G. E.; Vasiliadis, D. C.
2007-12-01
We examine on-demand multicasting in ad hoc networks. The Core Assisted Mesh Protocol (CAMP) is a well-known protocol for multicast routing in ad-hoc networks, generalizing the notion of core-based trees employed for internet multicasting into multicast meshes that have much richer connectivity than trees. On the other hand, wireless tree-based multicast routing protocols use much simpler structures for determining route paths, using only parent-child relationships. In this work, we compare the performance of the CAMP protocol against the performance of wireless tree-based multicast routing protocols, in terms of two important factors, namely packet delay and ratio of dropped packets.
Mining the literature: new methods to exploit keyword profiles
2012-01-01
Bibliographic records in the PubMed database of biomedical literature are annotated with Medical Subject Headings (MeSH) by curators, which summarize the content of the articles. Two recent publications explain how to generate profiles of MeSH terms for a set of bibliographic records and to use them to define any given concept by its associated literature. These concepts can then be related by their keyword profiles, and this can be used, for example, to detect new associations between genes and inherited diseases. See related research articles: http://www.biomedcentral.com/1471-2105/13/249/abstracthttp://genomemedicine.com/content/4/9/75/abstract PMID:23114100
NASA Astrophysics Data System (ADS)
Karimi-Fard, M.; Durlofsky, L. J.
2016-10-01
A comprehensive framework for modeling flow in porous media containing thin, discrete features, which could be high-permeability fractures or low-permeability deformation bands, is presented. The key steps of the methodology are mesh generation, fine-grid discretization, upscaling, and coarse-grid discretization. Our specialized gridding technique combines a set of intersecting triangulated surfaces by constructing approximate intersections using existing edges. This procedure creates a conforming mesh of all surfaces, which defines the internal boundaries for the volumetric mesh. The flow equations are discretized on this conforming fine mesh using an optimized two-point flux finite-volume approximation. The resulting discrete model is represented by a list of control-volumes with associated positions and pore-volumes, and a list of cell-to-cell connections with associated transmissibilities. Coarse models are then constructed by the aggregation of fine-grid cells, and the transmissibilities between adjacent coarse cells are obtained using flow-based upscaling procedures. Through appropriate computation of fracture-matrix transmissibilities, a dual-continuum representation is obtained on the coarse scale in regions with connected fracture networks. The fine and coarse discrete models generated within the framework are compatible with any connectivity-based simulator. The applicability of the methodology is illustrated for several two- and three-dimensional examples. In particular, we consider gas production from naturally fractured low-permeability formations, and transport through complex fracture networks. In all cases, highly accurate solutions are obtained with significant model reduction.
NASA Astrophysics Data System (ADS)
Rasyid, B.; Oda, M.; Omae, H.
2018-05-01
Soil-water and plant growth interaction is a primary key to develop environmental plant production system. The objective of this research is to evaluate change in soil water retention characteristics and plant response as the effect of continuous organic matter and plastic mulch application. The experiment was conducted in the plastic house field with plot size of 5 m (length) x 1 m (width). The field had treatments of plastic mulch type (mesh and poly) and no mulch, nitrogen (0, 10 and 40 kg N ha-1), and 2 ton ha-1 organic matter (incorporated into all plots). Water retention measurement using sand box method for low suction and pressure plate apparatus was applied for high suction. Completely randomized block experimental design and Duncan-MRT were used to analysis the effect of treatment on the parameters. Soil organic carbon and nitrogen increased slightly in both mulch types, but C:N ratio decreased in poly mulch which had the lowest value during two planting season. Various change in soil water retention was shown in different mulch type with mesh mulch had the highest result on lower suction, and control was the lowest water retention on the high suction. Soil water availability was highest in mesh mulch type followed by control and poly mulch type. This study could conclude that continuous incorporation of organic matter and mesh-plastic mulch was useful in achieving environments to improve soil C:N ratio and soil water retention.
NASA Astrophysics Data System (ADS)
Boscheri, Walter; Dumbser, Michael
2014-10-01
In this paper we present a new family of high order accurate Arbitrary-Lagrangian-Eulerian (ALE) one-step ADER-WENO finite volume schemes for the solution of nonlinear systems of conservative and non-conservative hyperbolic partial differential equations with stiff source terms on moving tetrahedral meshes in three space dimensions. A WENO reconstruction technique is used to achieve high order of accuracy in space, while an element-local space-time Discontinuous Galerkin finite element predictor on moving curved meshes is used to obtain a high order accurate one-step time discretization. Within the space-time predictor the physical element is mapped onto a reference element using a high order isoparametric approach, where the space-time basis and test functions are given by the Lagrange interpolation polynomials passing through a predefined set of space-time nodes. Since our algorithm is cell-centered, the final mesh motion is computed by using a suitable node solver algorithm. A rezoning step as well as a flattener strategy are used in some of the test problems to avoid mesh tangling or excessive element deformations that may occur when the computation involves strong shocks or shear waves. The ALE algorithm presented in this article belongs to the so-called direct ALE methods because the final Lagrangian finite volume scheme is based directly on a space-time conservation formulation of the governing PDE system, with the rezoned geometry taken already into account during the computation of the fluxes. We apply our new high order unstructured ALE schemes to the 3D Euler equations of compressible gas dynamics, for which a set of classical numerical test problems has been solved and for which convergence rates up to sixth order of accuracy in space and time have been obtained. We furthermore consider the equations of classical ideal magnetohydrodynamics (MHD) as well as the non-conservative seven-equation Baer-Nunziato model of compressible multi-phase flows with stiff relaxation source terms.
Hopkins, L. Nelson; Siddiqui, Adnan H.
2017-01-01
Atherosclerotic carotid artery stenosis (CS) continues to be a common cause of acute ischaemic stroke. Optimised medical therapy (OMT), the first-line treatment modality in CS, may reduce or delay – but it does not abolish – CS-related strokes. As per current AHA/ASA and ESC/ESVS/ESO guidelines, carotid artery stenting (CAS) is a less-invasive alternative to carotid endarterectomy (CEA) for CS revascularisation in primary and secondary stroke prevention. Ten-year follow-up from the CREST trial in patients with symptomatic and asymptomatic CS confirmed equipoise of CAS and CEA in the primary endpoint. Nevertheless CAS – using a widely open-cell, first-generation stent and first-generation (distal/filter) neuroprotection – has been criticised for its relative excess of (mostly minor) strokes by 30 days, a significant proportion of which were post-procedural. Atherosclerotic plaque protrusion through conventional carotid stent struts, confirmed on intravascular imaging, has been implicated as a leading mechanism of the relative excess of strokes with CAS vs. CEA, including delayed strokes with CAS. Different designs of mesh-covered carotid stents have been developed to prevent plaque prolapse. Several multi-centre/multi-specialty clinical studies with CGurad MicroNet-Covered Embolic Prevention Stent System (EPS) and RoadSaver/Casper were recently published and included routine DW-MRI cerebral imaging peri-procedurally and at 30 days (CGuard EPS). Data from more than 550 patients in mesh-covered carotid stent clinical studies to-date show an overall 30-day complication rate of ~1% with near-elimination of post-procedural events. While more (and long-term) evidence is still anticipated, these results – taken together with optimised intra-procedural neuroprotection in CAS (increased use of proximal systems including trans-carotid dynamic flow reversal) and the positive 12-month mesh-covered stent data reports in 2017 – are transforming the carotid revascularisation field today. Establishing effective algorithms to identify the asymptomatic subjects at stroke risk despite OMT, and large-scale studies with mesh-covered stents including long-term clinical and duplex ultrasound outcomes, are the next major goals. PMID:28798779
Aridity and decomposition processes in complex landscapes
NASA Astrophysics Data System (ADS)
Ossola, Alessandro; Nyman, Petter
2015-04-01
Decomposition of organic matter is a key biogeochemical process contributing to nutrient cycles, carbon fluxes and soil development. The activity of decomposers depends on microclimate, with temperature and rainfall being major drivers. In complex terrain the fine-scale variation in microclimate (and hence water availability) as a result of slope orientation is caused by differences in incoming radiation and surface temperature. Aridity, measured as the long-term balance between net radiation and rainfall, is a metric that can be used to represent variations in water availability within the landscape. Since aridity metrics can be obtained at fine spatial scales, they could theoretically be used to investigate how decomposition processes vary across complex landscapes. In this study, four research sites were selected in tall open sclerophyll forest along a aridity gradient (Budyko dryness index ranging from 1.56 -2.22) where microclimate, litter moisture and soil moisture were monitored continuously for one year. Litter bags were packed to estimate decomposition rates (k) using leaves of a tree species not present in the study area (Eucalyptus globulus) in order to avoid home-field advantage effects. Litter mass loss was measured to assess the activity of macro-decomposers (6mm litter bag mesh size), meso-decomposers (1 mm mesh), microbes above-ground (0.2 mm mesh) and microbes below-ground (2 cm depth, 0.2 mm mesh). Four replicates for each set of bags were installed at each site and bags were collected at 1, 2, 4, 7 and 12 months since installation. We first tested whether differences in microclimate due to slope orientation have significant effects on decomposition processes. Then the dryness index was related to decomposition rates to evaluate if small-scale variation in decomposition can be predicted using readily available information on rainfall and radiation. Decomposition rates (k), calculated fitting single pool negative exponential models, generally decreased with increasing aridity with k going from 0.0025 day-1 on equatorial (dry) facing slopes to 0.0040 day-1 on polar (wet) facing slopes. However, differences in temperature as a result of morning vs afternoon sun on east and west aspects, respectively, (not captured in the aridity metric) resulted in poor prediction of decomposition for the sites located in the intermediate aridity range. Overall the results highlight that relatively small differences in microclimate due to slope orientation can have large effects on decomposition. Future research will aim to refine the aridity metric to better resolve small scale variation in surface temperature which is important when up-scaling decomposition processes to landscapes.
NASA Astrophysics Data System (ADS)
Chen, G.; Chacón, L.; Barnes, D. C.
2012-03-01
A recent proof-of-principle study proposes an energy- and charge-conserving, fully implicit particle-in-cell algorithm in one dimension [1], which is able to use timesteps comparable to the dynamical timescale of interest. Here, we generalize the method to employ non-uniform meshes via a curvilinear map. The key enabling technology is a hybrid particle pusher [2], with particle positions updated in logical space and particle velocities updated in physical space. The self-adaptive, charge-conserving particle mover of Ref. [1] is extended to the non-uniform mesh case. The fully implicit implementation, using a Jacobian-free Newton-Krylov iterative solver, remains exactly charge- and energy-conserving. The extension of the formulation to multiple dimensions will be discussed. We present numerical experiments of 1D electrostatic, long-timescale ion-acoustic wave and ion-acoustic shock wave simulations, demonstrating that charge and energy are conserved to round-off for arbitrary mesh non-uniformity, and that the total momentum remains well conserved.[4pt] [1] Chen, Chac'on, Barnes, J. Comput. Phys. 230 (2011). [0pt] [2] Camporeale and Delzanno, Bull. Am. Phys. Soc. 56(6) (2011); Wang, et al., J. Plasma Physics, 61 (1999).
On Space-Time Inversion Invariance and its Relation to Non-Dissipatedness of a CESE Core Scheme
NASA Technical Reports Server (NTRS)
Chang, Sin-Chung
2006-01-01
The core motivating ideas of the space-time CESE method are clearly presented and critically analyzed. It is explained why these ideas result in all the simplifying and enabling features of the CESE method. A thorough discussion of the a scheme, a two-level non-dissipative CESE solver of a simple advection equation with two independent mesh variables and two equations per mesh point is also presented. It is shown that the scheme possesses some rather intriguing properties such as: (i) its two independent mesh variables separately satisfy two decoupled three-level leapfrog schemes and (ii) it shares with the leapfrog scheme the same amplification factors, even though the a scheme and the leapfrog scheme have completely different origins and structures. It is also explained why the leapfrog scheme is not as robust as the a scheme. The amplification factors/matrices of several non-dissipative schemes are carefully studied and the key properties that contribute to their non-dissipatedness are clearly spelled out. Finally we define and establish space-time inversion (STI) invariance for several non-dissipative schemes and show that their non-dissipatedness is a result of their STI invariance.
Feeding problems of infants and toddlers
Bernard-Bonnin, Anne-Claude
2006-01-01
OBJECTIVE To propose a diagnostic and therapeutic approach to feeding problems in early childhood. QUALITY OF EVIDENCE Articles were retrieved through a MEDLINE search from January 1990 to December 2005 using the MeSH terms eating disorders, infant, and child. Recommended practice is based mainly on levels II and III evidence. MAIN MESSAGE Feeding problems are classified under structural abnormalities, neurodevelopmental disabilities, and behavioural disorders, with overlap between categories. A medical approach also needs an evaluation of diet and an assessment of the interaction between parent and child. Treating medical or surgical conditions, increasing caloric intake, and counseling about general nutrition can alleviate mild to moderate problems. More complicated cases should be referred to multidisciplinary teams. Behavioural therapy aims to foster appropriate behaviour and discourage maladaptive behaviour. CONCLUSION Feeding problems in early childhood often have multifactorial causes and a substantial behavioural component. Family physicians have a key role in detecting problems, offering advice, managing mildly to moderately severe cases, and referring more complicated cases to multidisciplinary teams. PMID:17279184
Guraya, Salman Yousuf; Guraya, Shaista Salman
2017-05-01
There is a staggering upsurge in the incidence of plagiarism of scientific literature. Literature shows divergent views about the factors that make plagiarism reprehensible. This review explores the causes and remedies for the perennial academic problem of plagiarism. Data sources were searched for full text English language articles published from 2000 to 2015. Data selection was done using medical subject headline (MeSH) terms plagiarism, unethical writing, academic theft, retraction, medical field, and plagiarism detection software. Data extraction was undertaken by selecting titles from retrieved references and data synthesis identified key factors leading to plagiarism such as unawareness of research ethics, poor writing skills and pressure or publish mantra. Plagiarism can be managed by a balance among its prevention, detection by plagiarism detection software, and institutional sanctions against proven plagiarists. Educating researchers about ethical principles of academic writing and institutional support in training writers about academic integrity and ethical publications can curtail plagiarism.
NASA Astrophysics Data System (ADS)
Augustin, Christoph M.; Neic, Aurel; Liebmann, Manfred; Prassl, Anton J.; Niederer, Steven A.; Haase, Gundolf; Plank, Gernot
2016-01-01
Electromechanical (EM) models of the heart have been used successfully to study fundamental mechanisms underlying a heart beat in health and disease. However, in all modeling studies reported so far numerous simplifications were made in terms of representing biophysical details of cellular function and its heterogeneity, gross anatomy and tissue microstructure, as well as the bidirectional coupling between electrophysiology (EP) and tissue distension. One limiting factor is the employed spatial discretization methods which are not sufficiently flexible to accommodate complex geometries or resolve heterogeneities, but, even more importantly, the limited efficiency of the prevailing solver techniques which is not sufficiently scalable to deal with the incurring increase in degrees of freedom (DOF) when modeling cardiac electromechanics at high spatio-temporal resolution. This study reports on the development of a novel methodology for solving the nonlinear equation of finite elasticity using human whole organ models of cardiac electromechanics, discretized at a high para-cellular resolution. Three patient-specific, anatomically accurate, whole heart EM models were reconstructed from magnetic resonance (MR) scans at resolutions of 220 μm, 440 μm and 880 μm, yielding meshes of approximately 184.6, 24.4 and 3.7 million tetrahedral elements and 95.9, 13.2 and 2.1 million displacement DOF, respectively. The same mesh was used for discretizing the governing equations of both electrophysiology (EP) and nonlinear elasticity. A novel algebraic multigrid (AMG) preconditioner for an iterative Krylov solver was developed to deal with the resulting computational load. The AMG preconditioner was designed under the primary objective of achieving favorable strong scaling characteristics for both setup and solution runtimes, as this is key for exploiting current high performance computing hardware. Benchmark results using the 220 μm, 440 μm and 880 μm meshes demonstrate efficient scaling up to 1024, 4096 and 8192 compute cores which allowed the simulation of a single heart beat in 44.3, 87.8 and 235.3 minutes, respectively. The efficiency of the method allows fast simulation cycles without compromising anatomical or biophysical detail.
Augustin, Christoph M.; Neic, Aurel; Liebmann, Manfred; Prassl, Anton J.; Niederer, Steven A.; Haase, Gundolf; Plank, Gernot
2016-01-01
Electromechanical (EM) models of the heart have been used successfully to study fundamental mechanisms underlying a heart beat in health and disease. However, in all modeling studies reported so far numerous simplifications were made in terms of representing biophysical details of cellular function and its heterogeneity, gross anatomy and tissue microstructure, as well as the bidirectional coupling between electrophysiology (EP) and tissue distension. One limiting factor is the employed spatial discretization methods which are not sufficiently flexible to accommodate complex geometries or resolve heterogeneities, but, even more importantly, the limited efficiency of the prevailing solver techniques which are not sufficiently scalable to deal with the incurring increase in degrees of freedom (DOF) when modeling cardiac electromechanics at high spatio-temporal resolution. This study reports on the development of a novel methodology for solving the nonlinear equation of finite elasticity using human whole organ models of cardiac electromechanics, discretized at a high para-cellular resolution. Three patient-specific, anatomically accurate, whole heart EM models were reconstructed from magnetic resonance (MR) scans at resolutions of 220 μm, 440 μm and 880 μm, yielding meshes of approximately 184.6, 24.4 and 3.7 million tetrahedral elements and 95.9, 13.2 and 2.1 million displacement DOF, respectively. The same mesh was used for discretizing the governing equations of both electrophysiology (EP) and nonlinear elasticity. A novel algebraic multigrid (AMG) preconditioner for an iterative Krylov solver was developed to deal with the resulting computational load. The AMG preconditioner was designed under the primary objective of achieving favorable strong scaling characteristics for both setup and solution runtimes, as this is key for exploiting current high performance computing hardware. Benchmark results using the 220 μm, 440 μm and 880 μm meshes demonstrate efficient scaling up to 1024, 4096 and 8192 compute cores which allowed the simulation of a single heart beat in 44.3, 87.8 and 235.3 minutes, respectively. The efficiency of the method allows fast simulation cycles without compromising anatomical or biophysical detail. PMID:26819483
OpenCL-based vicinity computation for 3D multiresolution mesh compression
NASA Astrophysics Data System (ADS)
Hachicha, Soumaya; Elkefi, Akram; Ben Amar, Chokri
2017-03-01
3D multiresolution mesh compression systems are still widely addressed in many domains. These systems are more and more requiring volumetric data to be processed in real-time. Therefore, the performance is becoming constrained by material resources usage and an overall reduction in the computational time. In this paper, our contribution entirely lies on computing, in real-time, triangles neighborhood of 3D progressive meshes for a robust compression algorithm based on the scan-based wavelet transform(WT) technique. The originality of this latter algorithm is to compute the WT with minimum memory usage by processing data as they are acquired. However, with large data, this technique is considered poor in term of computational complexity. For that, this work exploits the GPU to accelerate the computation using OpenCL as a heterogeneous programming language. Experiments demonstrate that, aside from the portability across various platforms and the flexibility guaranteed by the OpenCL-based implementation, this method can improve performance gain in speedup factor of 5 compared to the sequential CPU implementation.
Effect of catalysts on dc corona discharge poisoning
NASA Astrophysics Data System (ADS)
Pekárek, S.
2011-02-01
The processes of ozone generation in non-thermal plasma produced by an electrical discharge in air at atmospheric pressure are burdened by the presence of nitrogen oxides, which on the one hand contribute to ozone generation and on the other hand are responsible for unpleasant discharge poisoning. The term discharge poisoning refers to the situation when the discharge ozone formation completely breaks down. Discharge poisoning can be affected by placing a catalyst in the discharge chamber. For the dc hollow needle to mesh corona discharge enhanced by the flow of air through the needle electrode we studied the effect of titanium dioxide TiO2, ZSM-5 zeolite or Cu++ZSM-5 zeolite on discharge poisoning by monitoring the ozone, nitrogen monoxide and nitrogen dioxide discharge production. We found that placing globules of any of these catalysts on the mesh decreases the energy density of the onset of discharge poisoning, and this energy density is smallest for a discharge with globules of a TiO2 on the mesh.
46 CFR 30.10-25 - Flame screen-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Flame screen—TB/ALL. The term flame screen means a fitted single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two fitted screens, both of corrosion-resistant wire, of at least 20 by 20...
46 CFR 30.10-25 - Flame screen-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Flame screen—TB/ALL. The term flame screen means a fitted single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two fitted screens, both of corrosion-resistant wire, of at least 20 by 20...
Information content in Medline record fields.
Kostoff, Ronald N; Block, Joel A; Stump, Jesse A; Pfeil, Kirstin M
2004-06-30
The authors have been conducting text mining analyses (extraction of useful information from text) of Medline records, using Abstracts as the main data source. For literature-based discovery, and other text mining applications as well, all records in a discipline need to be evaluated for determining prior art. Many Medline records do not contain Abstracts, but typically contain Titles and Mesh terms. Substitution of these fields for Abstracts in the non-Abstract records would restore the missing literature to some degree. Determine how well the information content of Title and Mesh fields approximates that of Abstracts in Medline records. Select historical Medline records related to Raynaud's Phenomenon that contain Abstracts. Determine the information content in the Abstract fields through text mining. Then, determine the information content in the Title fields, the Mesh fields, and the combined Title-Mesh fields, and compare with the information content in the Abstracts. Four metrics were used to compare the information content related to Raynaud's Phenomenon in the different fields: total number of phrases; number of unique phrases; content of factors from factor analyses; content of clusters from multi-link clustering. The Abstract field contains almost an order of magnitude more phrases than the other fields, and slightly more than an order of magnitude more unique phrases than the other fields. Each field used a factor matrix with 14 factors, and the combination of all 56 factors for the four fields represented 27 separate, but not unique, themes. These themes could be placed in two major categories, with two sub-categories per major category: Auto-immunity (antibodies, inflammation) and circulation (peripheral vessel circulation, coronary vessel circulation). All four sub-categories included representation from each field. Thus, while the focus of the representation of each field in each sub-category was moderately different, the four sub-category structure could be identified by analyzing the total factors in each field. In the cluster comparison phase of the study, the phrases used to create the clusters were the most important phrases identified for each factor. Thus, the factor matrix served as a filter for words used for clustering. While clusters were generated for all four fields, the Title hierarchy tended to be fragmented due to sparsity of the co-occurrence matrix that underlies the clusters. Therefore, the Title clusters were examined at only the lower levels of aggregation. The Abstract, Mesh, and Mesh + Title fields had the same first level taxonomy categories, auto-immunity and circulation. At the second level, the Abstract, Mesh, and Mesh + Title fields had the autoimmune diseases and antibodies sub-category in common. The Abstract and Mesh fields shared fascia inflammation as the other auto-immunity sub-category, while the other Mesh + Title sub-category focuses on vinyl chloride poisoning from industrial contact, and consequences of antineoplastic agents. However, in both cases, even though the words may be different, inflammation may be the common theme. For taxonomy generation, especially at the higher levels, each of the four fields has a similar thematic structure. At very detailed levels, the Mesh and Title fields run out of phrases relative to the Abstract field. Therefore, selection of field (s) to be employed for taxonomy generation depends on the objectives of the study, particularly the level of categorization required for the taxonomy. For information retrieval, or literature-based discovery, selection of the appropriate field again depends on the study objectives. If large queries, or large numbers of concepts or themes are desired, then the field with the largest number of technical phrases would be desirable. If queries or concepts represented by the more accepted popular terminology is adequate, then the smaller fields may be sufficient. Because of its established and controlled vocabulary, the Mesh field lags the Title or Abss the Title or Abstract fields in currency. Thus, the Title or Abstract fields would retrieve records with the most explicitly stated current concepts, but the Mesh field would capture a larger swath of fields that contained a concept of interest but perhaps had a wider range of specific terminology in the Abstract or Title text. In addition, this study provides the first validated estimate of the disparity in information retrieved through text mining limited to Titles and Mesh terms relative to entire Abstracts. As much of the older biomedical literature was entered into electronic databases without associated Abstracts, literature-based discovery exercises that search the older medical literature may miss a substantial proportion of relevant information. On the basis of this study, it may be estimated that up to a log order more information may be retrieved when complete Abstracts are searched.
Liu, Yifeng; Liang, Yongjie; Wishart, David
2015-07-01
PolySearch2 (http://polysearch.ca) is an online text-mining system for identifying relationships between biomedical entities such as human diseases, genes, SNPs, proteins, drugs, metabolites, toxins, metabolic pathways, organs, tissues, subcellular organelles, positive health effects, negative health effects, drug actions, Gene Ontology terms, MeSH terms, ICD-10 medical codes, biological taxonomies and chemical taxonomies. PolySearch2 supports a generalized 'Given X, find all associated Ys' query, where X and Y can be selected from the aforementioned biomedical entities. An example query might be: 'Find all diseases associated with Bisphenol A'. To find its answers, PolySearch2 searches for associations against comprehensive collections of free-text collections, including local versions of MEDLINE abstracts, PubMed Central full-text articles, Wikipedia full-text articles and US Patent application abstracts. PolySearch2 also searches 14 widely used, text-rich biological databases such as UniProt, DrugBank and Human Metabolome Database to improve its accuracy and coverage. PolySearch2 maintains an extensive thesaurus of biological terms and exploits the latest search engine technology to rapidly retrieve relevant articles and databases records. PolySearch2 also generates, ranks and annotates associative candidates and present results with relevancy statistics and highlighted key sentences to facilitate user interpretation. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Liu, Yifeng; Liang, Yongjie; Wishart, David
2015-01-01
PolySearch2 (http://polysearch.ca) is an online text-mining system for identifying relationships between biomedical entities such as human diseases, genes, SNPs, proteins, drugs, metabolites, toxins, metabolic pathways, organs, tissues, subcellular organelles, positive health effects, negative health effects, drug actions, Gene Ontology terms, MeSH terms, ICD-10 medical codes, biological taxonomies and chemical taxonomies. PolySearch2 supports a generalized ‘Given X, find all associated Ys’ query, where X and Y can be selected from the aforementioned biomedical entities. An example query might be: ‘Find all diseases associated with Bisphenol A’. To find its answers, PolySearch2 searches for associations against comprehensive collections of free-text collections, including local versions of MEDLINE abstracts, PubMed Central full-text articles, Wikipedia full-text articles and US Patent application abstracts. PolySearch2 also searches 14 widely used, text-rich biological databases such as UniProt, DrugBank and Human Metabolome Database to improve its accuracy and coverage. PolySearch2 maintains an extensive thesaurus of biological terms and exploits the latest search engine technology to rapidly retrieve relevant articles and databases records. PolySearch2 also generates, ranks and annotates associative candidates and present results with relevancy statistics and highlighted key sentences to facilitate user interpretation. PMID:25925572
Rossi, Angela; Wistlich, Laura; Heffels, Karl-Heinz; Walles, Heike; Groll, Jürgen
2016-08-01
In addition to dividing tissues into compartments, basement membranes are crucial as cell substrates and to regulate cellular behavior. The development of artificial basement membranes is indispensable for the ultimate formation of functional engineered tissues; however, pose a challenge due to their complex structure. Herein, biodegradable electrospun polyester meshes are presented, exhibiting isotropic or bipolar bioactivation as a biomimetic and biofunctional model of the natural basement membrane. In a one-step preparation process, reactive star-shaped prepolymer additives, which generate a hydrophilic fiber surface, are electrospun with cell-adhesion-mediating peptides, derived from major components of the basement membrane. Human skin cells adhere to the functionalized meshes, and long-term co-culture experiments confirm that the artificial basement membranes recapitulate and preserve tissue specific functions. Several layers of immortalized human keratinocytes grow on the membranes, differentiating toward the surface and expressing typical epithelial markers. Fibroblasts migrate into the reticular lamina mimicking part of the mesh. Both cells types begin to produce extracellular matrix proteins and to remodel the initial membrane. It is shown at the example of skin that the artificial basement membrane design provokes biomimetic responses of different cell types and can thus be used as basis for the future development of basement membrane containing tissues. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A novel finite volume discretization method for advection-diffusion systems on stretched meshes
NASA Astrophysics Data System (ADS)
Merrick, D. G.; Malan, A. G.; van Rooyen, J. A.
2018-06-01
This work is concerned with spatial advection and diffusion discretization technology within the field of Computational Fluid Dynamics (CFD). In this context, a novel method is proposed, which is dubbed the Enhanced Taylor Advection-Diffusion (ETAD) scheme. The model equation employed for design of the scheme is the scalar advection-diffusion equation, the industrial application being incompressible laminar and turbulent flow. Developed to be implementable into finite volume codes, ETAD places specific emphasis on improving accuracy on stretched structured and unstructured meshes while considering both advection and diffusion aspects in a holistic manner. A vertex-centered structured and unstructured finite volume scheme is used, and only data available on either side of the volume face is employed. This includes the addition of a so-called mesh stretching metric. Additionally, non-linear blending with the existing NVSF scheme was performed in the interest of robustness and stability, particularly on equispaced meshes. The developed scheme is assessed in terms of accuracy - this is done analytically and numerically, via comparison to upwind methods which include the popular QUICK and CUI techniques. Numerical tests involved the 1D scalar advection-diffusion equation, a 2D lid driven cavity and turbulent flow case. Significant improvements in accuracy were achieved, with L2 error reductions of up to 75%.
Combined open and laparoscopic approach to chronic pain after inguinal hernia repair.
Keller, Jennifer E; Stefanidis, Demitrios; Dolce, Charles J; Iannitti, David A; Kercher, Kent W; Heniford, B Todd
2008-08-01
Chronic groin pain is the most frequent long-term complication after inguinal hernia repair affecting up to 34 per cent of patients. Traditional surgical management includes groin exploration, mesh removal, and neurectomy. We evaluate outcomes of a combined laparoscopic and open approach to chronic pain after inguinal herniorrhaphy. All patients undergoing surgical exploration for chronic pain after inguinal herniorrhaphy were analyzed. In most, the operation consisted of mesh removal (open or laparoscopic), neurectomy, and placement of mesh in the opposite location of the first mesh (laparoscopic if the first was open and vice-versa). Main outcome measures included pain status, numbness, and hernia recurrence. Twenty-one patients (16 male and 5 female) with a mean age of 41 years (22-51 years) underwent surgical treatment for unilateral (n = 18) or bilateral (n = 3) groin pain. Percutaneous nerve block was unsuccessful in all patients. Four had previous surgery for pain. There were no complications. With a minimum of 6 weeks follow-up, 20 of 21 patients reported significant improvement or resolution of symptoms. A combined laparoscopic and open approach for postherniorrhaphy groin pain results in excellent patient satisfaction with minimal morbidity. It may be the preferred technique for the definitive management of chronic neuralgia after hernia repair.
A computational method for sharp interface advection
Bredmose, Henrik; Jasak, Hrvoje
2016-01-01
We devise a numerical method for passive advection of a surface, such as the interface between two incompressible fluids, across a computational mesh. The method is called isoAdvector, and is developed for general meshes consisting of arbitrary polyhedral cells. The algorithm is based on the volume of fluid (VOF) idea of calculating the volume of one of the fluids transported across the mesh faces during a time step. The novelty of the isoAdvector concept consists of two parts. First, we exploit an isosurface concept for modelling the interface inside cells in a geometric surface reconstruction step. Second, from the reconstructed surface, we model the motion of the face–interface intersection line for a general polygonal face to obtain the time evolution within a time step of the submerged face area. Integrating this submerged area over the time step leads to an accurate estimate for the total volume of fluid transported across the face. The method was tested on simple two-dimensional and three-dimensional interface advection problems on both structured and unstructured meshes. The results are very satisfactory in terms of volume conservation, boundedness, surface sharpness and efficiency. The isoAdvector method was implemented as an OpenFOAM® extension and is published as open source. PMID:28018619
The evolving block universe and the meshing together of times.
Ellis, George F R
2014-10-01
It has been proposed that spacetime should be regarded as an evolving block universe, bounded to the future by the present time, which continually extends to the future. This future boundary is defined at each time by measuring proper time along Ricci eigenlines from the start of the universe. A key point, then, is that physical reality can be represented at many different scales: hence, the passage of time may be seen as different at different scales, with quantum gravity determining the evolution of spacetime itself at the Planck scale, but quantum field theory and classical physics determining the evolution of events within spacetime at larger scales. The fundamental issue then arises as to how the effective times at different scales mesh together, leading to the concepts of global and local times. © 2014 New York Academy of Sciences.
3D model retrieval method based on mesh segmentation
NASA Astrophysics Data System (ADS)
Gan, Yuanchao; Tang, Yan; Zhang, Qingchen
2012-04-01
In the process of feature description and extraction, current 3D model retrieval algorithms focus on the global features of 3D models but ignore the combination of global and local features of the model. For this reason, they show less effective performance to the models with similar global shape and different local shape. This paper proposes a novel algorithm for 3D model retrieval based on mesh segmentation. The key idea is to exact the structure feature and the local shape feature of 3D models, and then to compares the similarities of the two characteristics and the total similarity between the models. A system that realizes this approach was built and tested on a database of 200 objects and achieves expected results. The results show that the proposed algorithm improves the precision and the recall rate effectively.
A Technique of Treating Negative Weights in WENO Schemes
NASA Technical Reports Server (NTRS)
Shi, Jing; Hu, Changqing; Shu, Chi-Wang
2000-01-01
High order accurate weighted essentially non-oscillatory (WENO) schemes have recently been developed for finite difference and finite volume methods both in structural and in unstructured meshes. A key idea in WENO scheme is a linear combination of lower order fluxes or reconstructions to obtain a high order approximation. The combination coefficients, also called linear weights, are determined by local geometry of the mesh and order of accuracy and may become negative. WENO procedures cannot be applied directly to obtain a stable scheme if negative linear weights are present. Previous strategy for handling this difficulty is by either regrouping of stencils or reducing the order of accuracy to get rid of the negative linear weights. In this paper we present a simple and effective technique for handling negative linear weights without a need to get rid of them.
A contact algorithm for shell problems via Delaunay-based meshing of the contact domain
NASA Astrophysics Data System (ADS)
Kamran, K.; Rossi, R.; Oñate, E.
2013-07-01
The simulation of the contact within shells, with all of its different facets, represents still an open challenge in Computational Mechanics. Despite the effort spent in the development of techniques for the simulation of general contact problems, an all-seasons algorithm applicable to complex shell contact problems is yet to be developed. This work focuses on the solution of the contact between thin shells by using a technique derived from the particle finite element method together with a rotation-free shell triangle. The key concept is to define a discretization of the contact domain (CD) by constructing a finite element mesh of four-noded tetrahedra that describes the potential contact volume. The problem is completed by using an assumed-strain approach to define an elastic contact strain over the CD.
NASA Astrophysics Data System (ADS)
Qiu, Wei; Xia, Lingzhi; Yang, Lanjun; Zhang, Qiaogen; Xiao, Lei; Chen, Li
2011-12-01
The ionic wind has good application prospects in the fields of air flow control and heat transfer enhancement. The key for successful applications is how to improve the velocity and how to increase the active area of the ionic wind. This paper designed a needle array-mesh type electrohydrodynamic (EHD) gas pump. The use of needle array electrode where corona discharge started simultaneously could enlarge the active area. The velocity of the ionic wind could increase by placing several single-stage ionic wind generators in series appropriately, called as serial staged generator. The maximum average flow velocity of 16.1 m/s and volumetric flow of 303.5 L/min were achieved at the outlet of a 25-stage gas pump and the conversion efficiency was approximately 2.2%.
Lamblin, Gery; Gouttenoire, Chloé; Panel, Laure; Moret, Stéphanie; Chene, Gautier; Courtieu, Christophe
2016-12-01
To compare apical correction in stage ≥3 cystocele between two mesh kits. This was a retrospective, nonrandomized study that compared two groups matched on anterior/apical POP-Q stage: 84 received Elevate Ant™ single-incision mesh (Elevate Ant group) and 42 Perigee™ transvaginal mesh (Perigee group). Follow-up at 1 and 2 years comprised objective (POP-Q) and subjective (PFDI-20, PFIQ-7, PISQ-12) assessments. The primary endpoint was objective success: 2-year apical POP-Q stage ≤1. Secondary endpoints were anterior POP-Q stage, subjective results and complications. Groups were comparable in terms of age (66.6 and 64.7 years, respectively; p = 0.19), BMI (both 25.4 kg/m 2 ; p = 0.93), and history of hysterectomy (7.2 % and 14.3 %; p = 0.21) or prolapse surgery (12 % and 14.3 %; p = 0.72). Operative time was shorter in the Elevate Ant group (54.1 vs. 62.5 min; p = 0.048), and the 2-year objective apical success rate was higher (92.9 % vs. 66.7 %; p < 0.0001), with better point C correction (-5 vs. -3.8; p = 0.006). Function improved in both groups, with significantly better PFIQ-7 (p = 0.03) and PFDI-20 (p = 0.02) scores in the Elevate Ant group at 2 years. Vaginal exposure was not seen in the Elevate Ant group but occurred in two patients in the Perigee group (p = 0.33). Factors associated with success were age >65 years (OR 7.16, 95 % CI 1.83 - 27.97) and treatment with Elevate Ant mesh (OR 10.16, 95 % CI 2.78 - 37.14). Postoperative stress urinary incontinence rate was greater with the Elevate Ant group (29.8 % and 16.7 %; p = 0.11). The use of the Elevate Ant mesh was associated with significantly better apical correction at 2 years. Function improved in both groups, but with a significantly better PFDI-20 score in the Elevate Ant group at 1 and 2 years. The postoperative stress urinary incontinence rate, however, tended to be greater in the Elevate Ant group. The results need confirming with longer follow-up of these cohorts and in randomized studies.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Navy personnel trained in whale identification, scientific research survey personnel, whale watch..., designed or configured so that the webbing (meshes) or nets are placed in the water column, usually held approximately vertically, and are designed to capture fish by entanglement, gilling, or wedging. The term...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Navy personnel trained in whale identification, scientific research survey personnel, whale watch..., designed or configured so that the webbing (meshes) or nets are placed in the water column, usually held approximately vertically, and are designed to capture fish by entanglement, gilling, or wedging. The term...
Return of ovulation and menses in postpartum nonlactating women: a systematic review.
Jackson, Emily; Glasier, Anna
2011-03-01
To estimate, from the literature, when nonlactating postpartum women regain fertility. We searched PubMed and Cochrane Library databases for all articles (in all languages) published in peer-reviewed journals from database inception through May 2010 for evidence related to the return of ovulation and menses in nonlactating postpartum women. Search terms included "Fertility" (Mesh) OR "Ovulation" (Mesh) OR "Ovulation Detection" (Mesh) OR "Ovulation Prediction" (Mesh) OR fertility OR ovulat* AND "Postpartum Period" (Mesh) OR postpartum OR puerperium AND Human AND Female. We included articles assessing nonlactating women's first ovulation postpartum. Studies in which women breastfed for any period of time or in whom lactation was suppressed with medications were excluded. We identified 1,623 articles; six articles reported four studies met our inclusion criteria. In three studies utilizing urinary pregnanediol levels to measure ovulation, mean day of first ovulation ranged from 45 to 94 days postpartum; 20%-71% of first menses were preceded by ovulation and 0%-60% of these ovulations were potentially fertile. In one study that used basal body temperature to measure ovulation, mean first ovulation occurred on day 74 postpartum; 33% of first menses were preceded by ovulation and 70% of these were potentially fertile. Most nonlactating women will not ovulate until 6 weeks postpartum. A small number of women will ovulate earlier, potentially putting them at risk for pregnancy sooner, although the fertility of these early ovulations is not well-established. The potential risk of pregnancy soon after delivery underscores the importance of initiating postpartum contraception in a timely fashion.
Challenges for Wireless Mesh Networks to provide reliable carrier-grade services
NASA Astrophysics Data System (ADS)
von Hugo, D.; Bayer, N.
2011-08-01
Provision of mobile and wireless services today within a competitive environment and driven by a huge amount of steadily emerging new services and applications is both challenge and chance for radio network operators. Deployment and operation of an infrastructure for mobile and wireless broadband connectivity generally requires planning effort and large investments. A promising approach to reduce expenses for radio access networking is offered by Wireless Mesh Networks (WMNs). Here traditional dedicated backhaul connections to each access point are replaced by wireless multi-hop links between neighbouring access nodes and few gateways to the backbone employing standard radio technology. Such a solution provides at the same time high flexibility in both deployment and the amount of offered capacity and shall reduce overall expenses. On the other hand currently available mesh solutions do not provide carrier grade service quality and reliability and often fail to cope with high traffic load. EU project CARMEN (CARrier grade MEsh Networks) was initiated to incorporate different heterogeneous technologies and new protocols to allow for reliable transmission over "best effort" radio channels, to support a reliable mobility and network management, self-configuration and dynamic resource usage, and thus to offer a permanent or temporary broadband access at high cost efficiency. The contribution provides an overview on preliminary project results with focus on main technical challenges from a research and implementation point of view. Especially impact of mesh topology on the overall system performance in terms of throughput and connection reliability and aspects of a dedicated hybrid mobility management solution will be discussed.
Eriksen, J R; Bisgaard, T; Assaadzadeh, S; Jorgensen, L N; Rosenberg, J
2013-08-01
Fibrin sealant for mesh fixation has significant positive effects on early outcome after laparoscopic ventral hernia repair (LVHR) compared with titanium tacks. Whether fibrin sealant fixation also results in better long-term outcome is unknown. We performed a randomized controlled trial including patients with umbilical hernia defects from 1.5 to 5 cm at three Danish hernia centres. We used a 12 cm circular mesh. Participants were randomized to fibrin sealant or titanium tack fixation. Patients were seen in the outpatient clinic at 1 and 12 months follow-up. Forty patients were included of whom 34 were available for intention to treat analysis after 1 year. There were no significant differences in pain, discomfort, fatigue, satisfaction or quality of life between the two groups at the 1-year follow-up. Five patients (26 %) in the fibrin sealant group and one (6 %) in the tack group were diagnosed with a recurrence at the 1-year follow-up (p = 0.182) (overall recurrence rate 17 %). Hernia defects in patients with recurrence were significantly larger than in those without recurrence (median 4.0 vs. 2.8 cm, p = 0.009). Patients with larger hernia defects and fibrin sealant mesh fixation had higher recurrence rates than expected, although the study was not powered for assessment of recurrence. There was no significant difference between groups in any parameters after the 1-year follow-up. The beneficial effects of mesh fixation with fibrin sealant on early outcome warrant further studies on optimization of the surgical technique to prevent recurrence.
Laparoscopic repair of inguinal hernia in adults
Yang, Xue-Fei
2016-01-01
Laparoscopic repair of inguinal hernia is mini-invasive and has confirmed effects. The procedures include intraperitoneal onlay mesh (IPOM) repair, transabdominal preperitoneal (TAPP) repair and total extraperitoneal (TEP) repair. These procedures have totally different anatomic point of view, process and technical key points from open operations. The technical details of these operations are discussed in this article, also the strategies of treatment for some special conditions. PMID:27867954
SLIM: an alternative Web interface for MEDLINE/PubMed searches – a preliminary study
Muin, Michael; Fontelo, Paul; Liu, Fang; Ackerman, Michael
2005-01-01
Background With the rapid growth of medical information and the pervasiveness of the Internet, online search and retrieval systems have become indispensable tools in medicine. The progress of Web technologies can provide expert searching capabilities to non-expert information seekers. The objective of the project is to create an alternative search interface for MEDLINE/PubMed searches using JavaScript slider bars. SLIM, or Slider Interface for MEDLINE/PubMed searches, was developed with PHP and JavaScript. Interactive slider bars in the search form controlled search parameters such as limits, filters and MeSH terminologies. Connections to PubMed were done using the Entrez Programming Utilities (E-Utilities). Custom scripts were created to mimic the automatic term mapping process of Entrez. Page generation times for both local and remote connections were recorded. Results Alpha testing by developers showed SLIM to be functionally stable. Page generation times to simulate loading times were recorded the first week of alpha and beta testing. Average page generation times for the index page, previews and searches were 2.94 milliseconds, 0.63 seconds and 3.84 seconds, respectively. Eighteen physicians from the US, Australia and the Philippines participated in the beta testing and provided feedback through an online survey. Most users found the search interface user-friendly and easy to use. Information on MeSH terms and the ability to instantly hide and display abstracts were identified as distinctive features. Conclusion SLIM can be an interactive time-saving tool for online medical literature research that improves user control and capability to instantly refine and refocus search strategies. With continued development and by integrating search limits, methodology filters, MeSH terms and levels of evidence, SLIM may be useful in the practice of evidence-based medicine. PMID:16321145
SLIM: an alternative Web interface for MEDLINE/PubMed searches - a preliminary study.
Muin, Michael; Fontelo, Paul; Liu, Fang; Ackerman, Michael
2005-12-01
With the rapid growth of medical information and the pervasiveness of the Internet, online search and retrieval systems have become indispensable tools in medicine. The progress of Web technologies can provide expert searching capabilities to non-expert information seekers. The objective of the project is to create an alternative search interface for MEDLINE/PubMed searches using JavaScript slider bars. SLIM, or Slider Interface for MEDLINE/PubMed searches, was developed with PHP and JavaScript. Interactive slider bars in the search form controlled search parameters such as limits, filters and MeSH terminologies. Connections to PubMed were done using the Entrez Programming Utilities (E-Utilities). Custom scripts were created to mimic the automatic term mapping process of Entrez. Page generation times for both local and remote connections were recorded. Alpha testing by developers showed SLIM to be functionally stable. Page generation times to simulate loading times were recorded the first week of alpha and beta testing. Average page generation times for the index page, previews and searches were 2.94 milliseconds, 0.63 seconds and 3.84 seconds, respectively. Eighteen physicians from the US, Australia and the Philippines participated in the beta testing and provided feedback through an online survey. Most users found the search interface user-friendly and easy to use. Information on MeSH terms and the ability to instantly hide and display abstracts were identified as distinctive features. SLIM can be an interactive time-saving tool for online medical literature research that improves user control and capability to instantly refine and refocus search strategies. With continued development and by integrating search limits, methodology filters, MeSH terms and levels of evidence, SLIM may be useful in the practice of evidence-based medicine.
Collisionless stellar hydrodynamics as an efficient alternative to N-body methods
NASA Astrophysics Data System (ADS)
Mitchell, Nigel L.; Vorobyov, Eduard I.; Hensler, Gerhard
2013-01-01
The dominant constituents of the Universe's matter are believed to be collisionless in nature and thus their modelling in any self-consistent simulation is extremely important. For simulations that deal only with dark matter or stellar systems, the conventional N-body technique is fast, memory efficient and relatively simple to implement. However when extending simulations to include the effects of gas physics, mesh codes are at a distinct disadvantage compared to Smooth Particle Hydrodynamics (SPH) codes. Whereas implementing the N-body approach into SPH codes is fairly trivial, the particle-mesh technique used in mesh codes to couple collisionless stars and dark matter to the gas on the mesh has a series of significant scientific and technical limitations. These include spurious entropy generation resulting from discreteness effects, poor load balancing and increased communication overhead which spoil the excellent scaling in massively parallel grid codes. In this paper we propose the use of the collisionless Boltzmann moment equations as a means to model the collisionless material as a fluid on the mesh, implementing it into the massively parallel FLASH Adaptive Mesh Refinement (AMR) code. This approach which we term `collisionless stellar hydrodynamics' enables us to do away with the particle-mesh approach and since the parallelization scheme is identical to that used for the hydrodynamics, it preserves the excellent scaling of the FLASH code already demonstrated on peta-flop machines. We find that the classic hydrodynamic equations and the Boltzmann moment equations can be reconciled under specific conditions, allowing us to generate analytic solutions for collisionless systems using conventional test problems. We confirm the validity of our approach using a suite of demanding test problems, including the use of a modified Sod shock test. By deriving the relevant eigenvalues and eigenvectors of the Boltzmann moment equations, we are able to use high order accurate characteristic tracing methods with Riemann solvers to generate numerical solutions which show excellent agreement with our analytic solutions. We conclude by demonstrating the ability of our code to model complex phenomena by simulating the evolution of a two-armed spiral galaxy whose properties agree with those predicted by the swing amplification theory.
First human use of hybrid synthetic/biologic mesh in ventral hernia repair: a multicenter trial.
Bittner, James G; El-Hayek, Kevin; Strong, Andrew T; LaPinska, Melissa Phillips; Yoo, Jin S; Pauli, Eric M; Kroh, Matthew
2018-03-01
Mesh options for reinforcement of ventral/incisional hernia (VIH) repair include synthetic or biologic materials. While each material has known advantages and disadvantages, little is understood about outcomes when these materials are used in combination. This multicenter study reports on the first human use of a novel synthetic/biologic hybrid mesh (Zenapro ® Hybrid Hernia Repair Device) for VIH repair. This prospective, multicenter post-market clinical trial enrolled consecutive adults who underwent elective VIH repair with hybrid mesh placed in the intraperitoneal or retromuscular/preperitoneal position. Patients were classified as Ventral Hernia Working Group (VHWG) grades 1-3 and had clean or clean-contaminated wounds. Outcomes of ventral and incisional hernia were compared using appropriate parametric tests. In all, 63 patients underwent VIH repair with hybrid mesh. Most were females (54.0%), had a mean age of 54.8 ± 10.9 years and mean body mass index of 34.5 ± 7.8 kg/m 2 , and classified as VHWG grade 2 (87.3%). Most defects were midline (92.1%) with a mean area of 106 ± 155 cm 2 . Cases were commonly classified as clean (92.1%) and were performed laparoscopically (60.3%). Primary fascial closure was achieved in 82.5% with 28.2% requiring component separation. Mesh location was frequently intraperitoneal (69.8%). Overall, 39% of patients available for follow-up at 12 months suffered surgical site events, which were generally more frequent after incisional hernia repair. Of these, seroma (23.7%) was most common, but few (8.5%) required procedural intervention. Other surgical site events that required procedural intervention included hematoma (1.7%), wound dehiscence (1.7%), and surgical site infection (3.4%). Recurrence rate was 6.8% (95% CI 2.2-16.6%) at 12-months postoperatively. Zenapro ® Hybrid Hernia Repair Device is safe and effective in VHWG grade 1-2 patients with clean wounds out to 12 months. Short-term outcomes and recurrence rate are acceptable. This hybrid mesh represents a novel option for reinforcement during VIH repair.
NASA Astrophysics Data System (ADS)
Nassiri, Ali; Vivek, Anupam; Abke, Tim; Liu, Bert; Lee, Taeseon; Daehn, Glenn
2017-06-01
Numerical simulations of high-velocity impact welding are extremely challenging due to the coupled physics and highly dynamic nature of the process. Thus, conventional mesh-based numerical methodologies are not able to accurately model the process owing to the excessive mesh distortion close to the interface of two welded materials. A simulation platform was developed using smoothed particle hydrodynamics, implemented in a parallel architecture on a supercomputer. Then, the numerical simulations were compared to experimental tests conducted by vaporizing foil actuator welding. The close correspondence of the experiment and modeling in terms of interface characteristics allows the prediction of local temperature and strain distributions, which are not easily measured.
Dynamic implicit 3D adaptive mesh refinement for non-equilibrium radiation diffusion
NASA Astrophysics Data System (ADS)
Philip, B.; Wang, Z.; Berrill, M. A.; Birke, M.; Pernice, M.
2014-04-01
The time dependent non-equilibrium radiation diffusion equations are important for solving the transport of energy through radiation in optically thick regimes and find applications in several fields including astrophysics and inertial confinement fusion. The associated initial boundary value problems that are encountered often exhibit a wide range of scales in space and time and are extremely challenging to solve. To efficiently and accurately simulate these systems we describe our research on combining techniques that will also find use more broadly for long term time integration of nonlinear multi-physics systems: implicit time integration for efficient long term time integration of stiff multi-physics systems, local control theory based step size control to minimize the required global number of time steps while controlling accuracy, dynamic 3D adaptive mesh refinement (AMR) to minimize memory and computational costs, Jacobian Free Newton-Krylov methods on AMR grids for efficient nonlinear solution, and optimal multilevel preconditioner components that provide level independent solver convergence.
An assessment of the visibility of MeSH-indexed medical web catalogs through search engines.
Zweigenbaum, P.; Darmoni, S. J.; Grabar, N.; Douyère, M.; Benichou, J.
2002-01-01
Manually indexed Internet health catalogs such as CliniWeb or CISMeF provide resources for retrieving high-quality health information. Users of these quality-controlled subject gateways are most often referred to them by general search engines such as Google, AltaVista, etc. This raises several questions, among which the following: what is the relative visibility of medical Internet catalogs through search engines? This study addresses this issue by measuring and comparing the visibility of six major, MeSH-indexed health catalogs through four different search engines (AltaVista, Google, Lycos, Northern Light) in two languages (English and French). Over half a million queries were sent to the search engines; for most of these search engines, according to our measures at the time the queries were sent, the most visible catalog for English MeSH terms was CliniWeb and the most visible one for French MeSH terms was CISMeF. PMID:12463965
Parameterizing unresolved obstacles with source terms in wave modeling: A real-world application
NASA Astrophysics Data System (ADS)
Mentaschi, Lorenzo; Kakoulaki, Georgia; Vousdoukas, Michalis; Voukouvalas, Evangelos; Feyen, Luc; Besio, Giovanni
2018-06-01
Parameterizing the dissipative effects of small, unresolved coastal features, is fundamental to improve the skills of wave models. The established technique to deal with this problem consists in reducing the amount of energy advected within the propagation scheme, and is currently available only for regular grids. To find a more general approach, Mentaschi et al., 2015b formulated a technique based on source terms, and validated it on synthetic case studies. This technique separates the parameterization of the unresolved features from the energy advection, and can therefore be applied to any numerical scheme and to any type of mesh. Here we developed an open-source library for the estimation of the transparency coefficients needed by this approach, from bathymetric data and for any type of mesh. The spectral wave model WAVEWATCH III was used to show that in a real-world domain, such as the Caribbean Sea, the proposed approach has skills comparable and sometimes better than the established propagation-based technique.
Numerical electromagnetic frequency domain analysis with discrete exterior calculus
NASA Astrophysics Data System (ADS)
Chen, Shu C.; Chew, Weng Cho
2017-12-01
In this paper, we perform a numerical analysis in frequency domain for various electromagnetic problems based on discrete exterior calculus (DEC) with an arbitrary 2-D triangular or 3-D tetrahedral mesh. We formulate the governing equations in terms of DEC for 3-D and 2-D inhomogeneous structures, and also show that the charge continuity relation is naturally satisfied. Then we introduce a general construction for signed dual volume to incorporate material information and take into account the case when circumcenters fall outside triangles or tetrahedrons, which may lead to negative dual volume without Delaunay triangulation. Then we examine the boundary terms induced by the dual mesh and provide a systematical treatment of various boundary conditions, including perfect magnetic conductor (PMC), perfect electric conductor (PEC), Dirichlet, periodic, and absorbing boundary conditions (ABC) within this method. An excellent agreement is achieved through the numerical calculation of several problems, including homogeneous waveguides, microstructured fibers, photonic crystals, scattering by a 2-D PEC, and resonant cavities.
NASA Astrophysics Data System (ADS)
Aftosmis, Michael J.
1992-10-01
A new node based upwind scheme for the solution of the 3D Navier-Stokes equations on adaptively refined meshes is presented. The method uses a second-order upwind TVD scheme to integrate the convective terms, and discretizes the viscous terms with a new compact central difference technique. Grid adaptation is achieved through directional division of hexahedral cells in response to evolving features as the solution converges. The method is advanced in time with a multistage Runge-Kutta time stepping scheme. Two- and three-dimensional examples establish the accuracy of the inviscid and viscous discretization. These investigations highlight the ability of the method to produce crisp shocks, while accurately and economically resolving viscous layers. The representation of these and other structures is shown to be comparable to that obtained by structured methods. Further 3D examples demonstrate the ability of the adaptive algorithm to effectively locate and resolve multiple scale features in complex 3D flows with many interacting, viscous, and inviscid structures.
On configurational forces for gradient-enhanced inelasticity
NASA Astrophysics Data System (ADS)
Floros, Dimosthenis; Larsson, Fredrik; Runesson, Kenneth
2018-04-01
In this paper we discuss how configurational forces can be computed in an efficient and robust manner when a constitutive continuum model of gradient-enhanced viscoplasticity is adopted, whereby a suitably tailored mixed variational formulation in terms of displacements and micro-stresses is used. It is demonstrated that such a formulation produces sufficient regularity to overcome numerical difficulties that are notorious for a local constitutive model. In particular, no nodal smoothing of the internal variable fields is required. Moreover, the pathological mesh sensitivity that has been reported in the literature for a standard local model is no longer present. Numerical results in terms of configurational forces are shown for (1) a smooth interface and (2) a discrete edge crack. The corresponding configurational forces are computed for different values of the intrinsic length parameter. It is concluded that the convergence of the computed configurational forces with mesh refinement depends strongly on this parameter value. Moreover, the convergence behavior for the limit situation of rate-independent plasticity is unaffected by the relaxation time parameter.
A wave superposition method formulated in digital acoustic space
NASA Astrophysics Data System (ADS)
Hwang, Yong-Sin
In this thesis, a new formulation of the Wave Superposition method is proposed wherein the conventional mesh approach is replaced by a simple 3-D digital work space that easily accommodates shape optimization for minimizing or maximizing radiation efficiency. As sound quality is in demand in almost all product designs and also because of fierce competition between product manufacturers, faster and accurate computational method for shape optimization is always desired. Because the conventional Wave Superposition method relies solely on mesh geometry, it cannot accommodate fast shape changes in the design stage of a consumer product or machinery, where many iterations of shape changes are required. Since the use of a mesh hinders easy shape changes, a new approach for representing geometry is introduced by constructing a uniform lattice in a 3-D digital work space. A voxel (a portmanteau, a new word made from combining the sound and meaning, of the words, volumetric and pixel) is essentially a volume element defined by the uniform lattice, and does not require separate connectivity information as a mesh element does. In the presented method, geometry is represented with voxels that can easily adapt to shape changes, therefore it is more suitable for shape optimization. The new method was validated by computing radiated sound power of structures of simple and complex geometries and complex mode shapes. It was shown that matching volume velocity is a key component to an accurate analysis. A sensitivity study showed that it required at least 6 elements per acoustic wavelength, and a complexity study showed a minimal reduction in computational time.
European Hernia Society guidelines on prevention and treatment of parastomal hernias.
Antoniou, S A; Agresta, F; Garcia Alamino, J M; Berger, D; Berrevoet, F; Brandsma, H-T; Bury, K; Conze, J; Cuccurullo, D; Dietz, U A; Fortelny, R H; Frei-Lanter, C; Hansson, B; Helgstrand, F; Hotouras, A; Jänes, A; Kroese, L F; Lambrecht, J R; Kyle-Leinhase, I; López-Cano, M; Maggiori, L; Mandalà, V; Miserez, M; Montgomery, A; Morales-Conde, S; Prudhomme, M; Rautio, T; Smart, N; Śmietański, M; Szczepkowski, M; Stabilini, C; Muysoms, F E
2018-02-01
International guidelines on the prevention and treatment of parastomal hernias are lacking. The European Hernia Society therefore implemented a Clinical Practice Guideline development project. The guidelines development group consisted of general, hernia and colorectal surgeons, a biostatistician and a biologist, from 14 European countries. These guidelines conformed to the AGREE II standards and the GRADE methodology. The databases of MEDLINE, CINAHL, CENTRAL and the gray literature through OpenGrey were searched. Quality assessment was performed using Scottish Intercollegiate Guidelines Network checklists. The guidelines were presented at the 38th European Hernia Society Congress and each key question was evaluated in a consensus voting of congress participants. End colostomy is associated with a higher incidence of parastomal hernia, compared to other types of stomas. Clinical examination is necessary for the diagnosis of parastomal hernia, whereas computed tomography scan or ultrasonography may be performed in cases of diagnostic uncertainty. Currently available classifications are not validated; however, we suggest the use of the European Hernia Society classification for uniform research reporting. There is insufficient evidence on the policy of watchful waiting, the route and location of stoma construction, and the size of the aperture. The use of a prophylactic synthetic non-absorbable mesh upon construction of an end colostomy is strongly recommended. No such recommendation can be made for other types of stomas at present. It is strongly recommended to avoid performing a suture repair for elective parastomal hernia. So far, there is no sufficient comparative evidence on specific techniques, open or laparoscopic surgery and specific mesh types. However, a mesh without a hole is suggested in preference to a keyhole mesh when laparoscopic repair is performed. An evidence-based approach to the diagnosis and management of parastomal hernias reveals the lack of evidence on several topics, which need to be addressed by multicenter trials. Parastomal hernia prevention using a prophylactic mesh for end colostomies reduces parastomal herniation. Clinical outcomes should be audited and adverse events must be reported.
Automatic two- and three-dimensional mesh generation based on fuzzy knowledge processing
NASA Astrophysics Data System (ADS)
Yagawa, G.; Yoshimura, S.; Soneda, N.; Nakao, K.
1992-09-01
This paper describes the development of a novel automatic FEM mesh generation algorithm based on the fuzzy knowledge processing technique. A number of local nodal patterns are stored in a nodal pattern database of the mesh generation system. These nodal patterns are determined a priori based on certain theories or past experience of experts of FEM analyses. For example, such human experts can determine certain nodal patterns suitable for stress concentration analyses of cracks, corners, holes and so on. Each nodal pattern possesses a membership function and a procedure of node placement according to this function. In the cases of the nodal patterns for stress concentration regions, the membership function which is utilized in the fuzzy knowledge processing has two meanings, i.e. the “closeness” of nodal location to each stress concentration field as well as “nodal density”. This is attributed to the fact that a denser nodal pattern is required near a stress concentration field. What a user has to do in a practical mesh generation process are to choose several local nodal patterns properly and to designate the maximum nodal density of each pattern. After those simple operations by the user, the system places the chosen nodal patterns automatically in an analysis domain and on its boundary, and connects them smoothly by the fuzzy knowledge processing technique. Then triangular or tetrahedral elements are generated by means of the advancing front method. The key issue of the present algorithm is an easy control of complex two- or three-dimensional nodal density distribution by means of the fuzzy knowledge processing technique. To demonstrate fundamental performances of the present algorithm, a prototype system was constructed with one of object-oriented languages, Smalltalk-80 on a 32-bit microcomputer, Macintosh II. The mesh generation of several two- and three-dimensional domains with cracks, holes and junctions was presented as examples.
Langrehr, J M; Schmidt, S C; Neuhaus, P
2005-08-01
Laparoscopic inguinal hernia repair offers more rapid recovery and less pain than with the traditional open approach. However, injury to the nerves of the lumbar plexus with subsequent chronic pain or neuralgia has a reported incidence of 2% during laparoscopic hernia repair, particularly when the transabdominal preperitoneal technique (TAPP) is used. These complications are inherent to the use of staples for fixation of the mesh. To avoid nerve irritation, we considered the use of fibrin sealant for the fixation of the mesh instead of staples. The aim of this study was to evaluate this technique and to compare the short-term follow-up of these patients with patients who underwent the staple repair technique. This is the first reported use of fibrin sealant in laparoscopic TAPP hernia repair. Between September and November 2004, we performed 17 consecutive laparoscopic hernia repairs (TAPP) in 14 patients (3 bilateral hernias) with primary hernias. The prosthetic mesh was fixed (10 x 15 cm) with 1 ml fibrin. The fibrin was applied using a special laparoscopic applicator. The peritoneum was closed with absorbable sutures. The postoperative course of these patients was compared with a cohort of matched patients who received the traditional staple fixation of the prosthetic mesh. Patients were evaluated at a median follow-up of 10.4 months (3.8-16.0 months). All patients underwent postoperative physical examinations. No recurrent hernia was found. There were 2 seromas and one hematoma in the stapled group. In the stapled group, one patient had pain in the area of the lateral femoral cutaneous nerve. There was no postoperative complication in the non-stapled group. Fibrin fixation of the mesh during laparoscopic transabdominal preperitoneal inguinal hernia repair is feasible without higher risk of recurrences. In addition the fibrin fixation method may decrease postoperative neuralgia and reduce the incidence of postoperative seromas and hematomas.
An updated systematic review on the possible effect of nonylphenol on male fertility.
Noorimotlagh, Zahra; Haghighi, Neemat Jaafarzadeh; Ahmadimoghadam, Mehdi; Rahim, Fakher
2017-02-01
Diverse industries like detergents, resins and polymers, hair dyes, intravaginal spermicides, and pesticides produce endocrine disruptor (ED)-containing wastewaters that have hazardous effects on the environment and public health. Nonylphenol (NP) is a chemical substance that consists of a phenolic group and an attached lipophilic linear nonyl chain. NP has weak estrogenic activity and affects estrogen receptor (ER), as well as induces male infertility via a negative impact on spermatogenesis and sperm quality. The aim of this study was to comprehensively review all available literature about the side effects of NP on the male genital system. We systematically searched Scopus and PubMed using MeSH terms that include "Organic Chemicals," "Infertility," "Infertility, Male," "Nonylphenol", ("Infertility, Male"[Mesh]) OR "Nonylphenol" [Supplementary Concept]) OR "Prostate"[Mesh]) OR "Spermatozoa"[Mesh]) OR "Sertoli Cells"[Mesh]) OR "Leydig Cells"[Mesh] OR "Male accessory gland" OR "Epididym" OR "Reproductive toxicity"), and all other possible combinations from January 1, 1970, to September 15, 2016, with language limit. The initial search identified 117,742 potentially eligible studies, of which 33 met the established inclusion criteria and were included in the analysis. Thirty-three selected studies include animal model (n = 18), cell line (n = 15), human model (n = 1), morphology (n = 13), sperm quality (n = 17), and toxicity (n = 14). This review highlighted the evidence for the ED effect of NP that acts through interference with ER, discussing male reproductive tract perturbations. We critically discuss the available evidence on the effect of NP on sperm quality (such as motility, viability, sperm count, and sperm concentration), dramatic morphological changes (such as change of weights of testes and epididymis), and biochemical changes related to oxidative stress in testes. Finally, it is important to take caution with the continued use of NP that disrupts male reproductive health.
Samavedi, Satyavrata; Vaidya, Prasad; Gaddam, Prudhvidhar; Whittington, Abby R; Goldstein, Aaron S
2014-12-01
Although bone-patellar tendon-bone (B-PT-B) autografts are the gold standard for repair of anterior cruciate ligament ruptures, they suffer from drawbacks such as donor site morbidity and limited supply. Engineered tissues modeled after B-PT-B autografts are promising alternatives because they have the potential to regenerate connective tissue and facilitate osseointegration. Towards the long-term goal of regenerating ligaments and their bony insertions, the objective of this study was to construct 2D meshes and 3D cylindrical composite scaffolds - possessing simultaneous region-wise differences in fiber orientation, diameter, chemistry and mechanical properties - by electrospinning two different polymers from off-set spinnerets. Using a dual drum collector, 2D meshes consisting of an aligned polycaprolactone (PCL) fiber region, randomly oriented poly(lactide-co-glycolide) (PLGA) fiber region and a transition region (comprised of both PCL and PLGA fibers) were prepared, and region-wise differences were confirmed by microscopy and tensile testing. Bone marrow stromal cells (BMSCs) cultured on these meshes exhibited random orientations and low aspect ratios on the random PLGA regions, and high aspect ratios and alignment on the aligned PCL regions. Next, meshes containing an aligned PCL region flanked by two transition regions and two randomly oriented PLGA regions were prepared and processed into 3D cylindrical composite scaffolds using an interpenetrating photo-crosslinkable polyethylene glycol diacrylate hydrogel to recapitulate the shape of B-PT-B autografts. Tensile testing indicated that cylindrical composites were mechanically robust, and eventually failed due to stress concentration in the aligned PCL region. In summary, this study demonstrates a process to fabricate electrospun meshes possessing region-wise differences in properties that can elicit region-dependent cell responses, and be readily processed into scaffolds with the shape of B-PT-B autografts. © 2014 Wiley Periodicals, Inc.
Søgaard, Mette; Andersen, Jens P; Schønheyder, Henrik C
2012-04-01
There is inconsistency in the terminology used to describe bacteremia. To demonstrate the impact on information retrieval, we compared the yield of articles from PubMed MEDLINE using the terms "bacteremia," "bloodstream infection," and "septicemia." We searched for articles published between 1966 and 2009, and depicted the relationships among queries graphically. To examine the content of the retrieved articles, we extracted all Medical Subject Headings (MeSH) terms and compared topic similarity using a cosine measure. The recovered articles differed greatly by term, and only 53 articles were captured by all terms. Of the articles retrieved by the "bacteremia" query, 21,438 (84.1%) were not captured when searching for "bloodstream infection" or "septicemia." Likewise, only 2,243 of the 11,796 articles recovered by free-text query for "bloodstream infection" were retrieved by the "bacteremia" query (19%). Entering "bloodstream infection" as a phrase, 46.1% of the records overlapped with the "bacteremia" query. Similarity measures ranged from 0.52 to 0.78 and were lowest for "bloodstream infection" as a phrase compared with "septicemia." Inconsistent terminology has a major impact on the yield of queries. Agreement on terminology should be sought and promoted by scientific journals. An immediate solution is to add "bloodstream infection" as entry term for bacteremia in the MeSH vocabulary. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Study on cavitation effect of mechanical seals with laser-textured porous surface
NASA Astrophysics Data System (ADS)
Liu, T.; Chen, H. l.; Liu, Y. H.; Wang, Q.; Liu, Z. B.; Hou, D. H.
2012-11-01
Study on the mechanisms underlying generation of hydrodynamic pressure effect associated with laser-textured porous surface on mechanical seal, is the key to seal and lubricant properties. The theory model of mechanical seals with laser-textured porous surface (LES-MS) based on cavitation model was established. The LST-MS was calculated and analyzed by using Fluent software with full cavitation model and non-cavitation model and film thickness was predicted by the dynamic mesh technique. The results indicate that the effect of hydrodynamic pressure and cavitation are the important reasons to generate liquid film opening force on LST-MS; Cavitation effect can enhance hydrodynamic pressure effect of LST-MS; The thickness of liquid film could be well predicted with the method of dynamic mesh technique on Fluent and it becomes larger as the increasing of shaft speed and the decreasing of pressure.
Mathematical model for the Bridgman-Stockbarger crystal growing system
NASA Technical Reports Server (NTRS)
Roberts, G. O.
1986-01-01
In a major technical breakthrough, a computer model for Bridgman-Stockbarger crystal growth was developed. The model includes melt convection, solute effects, thermal conduction in the ampule, melt, and crystal, and the determination of the curved moving crystal-melt interface. The key to the numerical method is the use of a nonuniform computational mesh which moves with the interface, so that the interface is a mesh surface. In addition, implicit methods are used for advection and diffusion of heat, concentration, and vorticity, for interface movement, and for internal gracity waves. This allows large time-steps without loss of stability or accuracy. Numerical results are presented for the interface shape, temperature distribution, and concentration distribution, in steady-state crystl growth. Solutions are presented for two test cases using water, with two different salts in solution. The two diffusivities differ by a factor of ten, and the concentrations differ by a factor of twenty.
Status Report on NEAMS PROTEUS/ORIGEN Integration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wieselquist, William A
2016-02-18
The US Department of Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program has contributed significantly to the development of the PROTEUS neutron transport code at Argonne National Laboratory and to the Oak Ridge Isotope Generation and Depletion Code (ORIGEN) depletion/decay code at Oak Ridge National Laboratory. PROTEUS’s key capability is the efficient and scalable (up to hundreds of thousands of cores) neutron transport solver on general, unstructured, three-dimensional finite-element-type meshes. The scalability and mesh generality enable the transfer of neutron and power distributions to other codes in the NEAMS toolkit for advanced multiphysics analysis. Recently, ORIGEN has received considerablemore » modernization to provide the high-performance depletion/decay capability within the NEAMS toolkit. This work presents a description of the initial integration of ORIGEN in PROTEUS, mainly performed during FY 2015, with minor updates in FY 2016.« less
Matthews, Brent D; Pratt, Broc L; Pollinger, Harrison S; Backus, Charles L; Kercher, Kent W; Sing, R F; Heniford, B Todd
2003-10-01
The development of intra-abdominal adhesions, bowel obstruction, and enterocutaneous fistulas are potentially severe complications related to the intraperitoneal placement of prosthetic biomaterials. The purpose of this study was to determine the natural history of adhesion formation to polypropylene mesh and two types of polytetrafluoroethylene (ePTFE) mesh when placed intraperitoneally in a rabbit model that simulates laparoscopic ventral hernia repair. Thirty New Zealand white rabbits were used for this study. A 10-cm midline incision was performed for intra-abdominal access and a 2 cm x 2 cm piece of mesh (n = 60) was sewn to an intact peritoneum on each side of the midline. Two types of ePTFE mesh (Dual Mesh and modified Dual Mesh, W.L. Gore & Assoc., Flagstaff, AZ) and polypropylene mesh were compared. The rate of adhesion formation was evaluated by direct visualization using microlaparoscopy (2-mm endoscope/trocar) at 7 days, 3 weeks, 9 weeks, and 16 weeks after mesh implantation. Adhesions to the prosthetic mesh were scored for extent (%) using the Modified Diamond Scale (0 = 0%, 1
Navier-Stokes Aerodynamic Simulation of the V-22 Osprey on the Intel Paragon MPP
NASA Technical Reports Server (NTRS)
Vadyak, Joseph; Shrewsbury, George E.; Narramore, Jim C.; Montry, Gary; Holst, Terry; Kwak, Dochan (Technical Monitor)
1995-01-01
The paper will describe the Development of a general three-dimensional multiple grid zone Navier-Stokes flowfield simulation program (ENS3D-MPP) designed for efficient execution on the Intel Paragon Massively Parallel Processor (MPP) supercomputer, and the subsequent application of this method to the prediction of the viscous flowfield about the V-22 Osprey tiltrotor vehicle. The flowfield simulation code solves the thin Layer or full Navier-Stoke's equation - for viscous flow modeling, or the Euler equations for inviscid flow modeling on a structured multi-zone mesh. In the present paper only viscous simulations will be shown. The governing difference equations are solved using a time marching implicit approximate factorization method with either TVD upwind or central differencing used for the convective terms and central differencing used for the viscous diffusion terms. Steady state or Lime accurate solutions can be calculated. The present paper will focus on steady state applications, although time accurate solution analysis is the ultimate goal of this effort. Laminar viscosity is calculated using Sutherland's law and the Baldwin-Lomax two layer algebraic turbulence model is used to compute the eddy viscosity. The Simulation method uses an arbitrary block, curvilinear grid topology. An automatic grid adaption scheme is incorporated which concentrates grid points in high density gradient regions. A variety of user-specified boundary conditions are available. This paper will present the application of the scalable and superscalable versions to the steady state viscous flow analysis of the V-22 Osprey using a multiple zone global mesh. The mesh consists of a series of sheared cartesian grid blocks with polar grids embedded within to better simulate the wing tip mounted nacelle. MPP solutions will be shown in comparison to equivalent Cray C-90 results and also in comparison to experimental data. Discussions on meshing considerations, wall clock execution time, load balancing, and scalability will be provided.
Huang, Huajun; Xiang, Chunling; Zeng, Canjun; Ouyang, Hanbin; Wong, Kelvin Kian Loong; Huang, Wenhua
2015-12-01
We improved the geometrical modeling procedure for fast and accurate reconstruction of orthopedic structures. This procedure consists of medical image segmentation, three-dimensional geometrical reconstruction, and assignment of material properties. The patient-specific orthopedic structures reconstructed by this improved procedure can be used in the virtual surgical planning, 3D printing of real orthopedic structures and finite element analysis. A conventional modeling consists of: image segmentation, geometrical reconstruction, mesh generation, and assignment of material properties. The present study modified the conventional method to enhance software operating procedures. Patient's CT images of different bones were acquired and subsequently reconstructed to give models. The reconstruction procedures were three-dimensional image segmentation, modification of the edge length and quantity of meshes, and the assignment of material properties according to the intensity of gravy value. We compared the performance of our procedures to the conventional procedures modeling in terms of software operating time, success rate and mesh quality. Our proposed framework has the following improvements in the geometrical modeling: (1) processing time: (femur: 87.16 ± 5.90 %; pelvis: 80.16 ± 7.67 %; thoracic vertebra: 17.81 ± 4.36 %; P < 0.05); (2) least volume reduction (femur: 0.26 ± 0.06 %; pelvis: 0.70 ± 0.47, thoracic vertebra: 3.70 ± 1.75 %; P < 0.01) and (3) mesh quality in terms of aspect ratio (femur: 8.00 ± 7.38 %; pelvis: 17.70 ± 9.82 %; thoracic vertebra: 13.93 ± 9.79 %; P < 0.05) and maximum angle (femur: 4.90 ± 5.28 %; pelvis: 17.20 ± 19.29 %; thoracic vertebra: 3.86 ± 3.82 %; P < 0.05). Our proposed patient-specific geometrical modeling requires less operating time and workload, but the orthopedic structures were generated at a higher rate of success as compared with the conventional method. It is expected to benefit the surgical planning of orthopedic structures with less operating time and high accuracy of modeling.
Willms, A; Schaaf, S; Schwab, R; Richardsen, I; Bieler, D; Wagner, B; Güsgen, C
2016-12-01
The open abdomen has become a standard technique in the management of critically ill patients undergoing surgery for severe intra-abdominal conditions. Negative pressure and mesh-mediated fascial traction are commonly used and achieve low fistula rates and high fascial closure rates. In this study, long-term results of a standardised treatment approach are presented. Fifty-five patients who underwent OA management for different indications at our institution from 2006 to 2013 were enrolled. All patients were treated under a standardised algorithm that uses a combination of vacuum-assisted wound closure and mesh-mediated fascial traction. Structured follow-up assessments were offered to patients and included a medical history, a clinical examination and abdominal ultrasonography. The data obtained were statistically analysed. The fascial closure rate was 74 % in an intention-to-treat analysis and 89 % in a per-protocol analysis. The fistula rate was 1.8 %. Thirty-four patients attended follow-up. The median follow-up was 46 months (range 12-88 months). Incisional hernias developed in 35 %. Patients with hernias needed more operative procedures (10.3 vs 3.4, p = 0.03) than patients without hernia formation. A Patient Observer Scar Assessment Scale (POSAS) of 31.1 was calculated. Patients with symptomatic hernias (NAS of 2-10) had a significantly lower mean POSAS score (p = 0.04). Vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) seem to result in low complication rates and high fascial closure rates. Abdominal wall reconstruction, which is a challenging and complex procedure and causes considerable patient discomfort, can thus be avoided in the majority of cases. Available results are based on studies involving only a small number of cases. Multi-centre studies and registry-based data are therefore needed to validate these findings.
NASA Technical Reports Server (NTRS)
Schultz, Chris; Carey, Larry; Schultz, Elise V.; Stano, Geoffrey; Gatlin, Patrick N.; Kozlowski, Danielle M.; Blakeslee, Rich J.; Goodman, Steve
2013-01-01
Key points this analysis will address: 1) What physically is going on in the cloud when there is a jump in lightning? -- Updraft variations, Ice fluxes 2) How do these processes fit in with severe storm conceptual models? 3) What would this information provide an end user? --Relate LJA to radar observations, like changes in reflectivity, MESH, VIL, etc. based multi -Doppler derived physical relationships
Polymer fiber-based models of connective tissue repair and healing.
Lee, Nancy M; Erisken, Cevat; Iskratsch, Thomas; Sheetz, Michael; Levine, William N; Lu, Helen H
2017-01-01
Physiologically relevant models of wound healing are essential for understanding the biology of connective tissue repair and healing. They can also be used to identify key cellular processes and matrix characteristics critical for the design of soft tissue grafts. Modeling the various stages of repair post tendon injury, polymer meshes of varying fiber diameter (nano-1 (390 nm) < nano-2 (740 nm) < micro (1420 nm)) were produced. Alignment was also introduced in the nano-2 group to model matrix undergoing biological healing rather than scar formation. The response of human tendon fibroblasts on these model substrates were evaluated over time as a function of fiber diameter and alignment. It was observed that the repair models of unaligned nanoscale fibers enhanced cell growth and collagen synthesis, while these outcomes were significantly reduced in the mature repair model consisting of unaligned micron-sized fibers. Organization of paxillin and actin on unaligned meshes was enhanced on micro- compared to nano-sized fibers, while the expression and activity of RhoA and Rac1 were greater on nanofibers. In contrast, aligned nanofibers promoted early cell organization, while reducing excessive cell growth and collagen production in the long term. These results show that the early-stage repair model of unaligned nanoscale fibers elicits a response characteristic of the proliferative phase of wound repair, while the more mature model consisting of unaligned micron-sized fibers is more representative of the remodeling phase by supporting cell organization while suppressing growth and biosynthesis. Interestingly, introduction of fiber alignment in the nanofiber model alters fibroblast response from repair to healing, implicating matrix alignment as a critical design factor for circumventing scar formation and promoting biological healing of soft tissue injuries. Copyright © 2016 Elsevier Ltd. All rights reserved.
Capozzi, F; Giordano, S; Aboal, J R; Adamo, P; Bargagli, R; Boquete, T; Di Palma, A; Real, C; Reski, R; Spagnuolo, V; Steinbauer, K; Tretiach, M; Varela, Z; Zechmeister, H; Fernández, J A
2016-07-01
To develop an internationally standardized protocol for the moss bag technique application, the research team participating in the FP7 European project "MOSSclone" focused on the optimization of the moss bags exposure in terms of bag characteristics (shape of the bags, mesh size, weight/surface ratio), duration and height of exposure by comparing traditional moss bags to a new concept bag, "Mossphere". In particular, the effects of each variable on the metal uptake from the air were evaluated by a systematic experimental design carried out in urban, industrial, agricultural and background areas of three European countries with oceanic, Mediterranean and continental climate. The results evidenced that the shape, the mesh size of the bags and the exposure height (in the tested ranges), did not significantly influence the uptake capacity of the transplanted moss. The aspects more affecting the element uptake were represented by the density of the moss inside the bags and the relative ratio between its weight and the surface area of the bag. We found that, the lower the density, the higher the uptake recorded. Moreover, three weeks of exposure were not enough to have a consistent uptake signal in all the environments tested, thus we suggest an exposure period not shorter than 6 weeks, which is appropriate in most situations. The above results were confirmed in all the countries and scenarios tested. The adoption of a shared exposure protocol by the research community is strongly recommended since it is a key aspect to make biomonitoring surveys directly comparable, also in view of its recognition as a monitoring method by the EU legislation. Copyright © 2016 Elsevier Ltd. All rights reserved.
A locomotive-track coupled vertical dynamics model with gear transmissions
NASA Astrophysics Data System (ADS)
Chen, Zaigang; Zhai, Wanming; Wang, Kaiyun
2017-02-01
A gear transmission system is a key element in a locomotive for the transmission of traction or braking forces between the motor and the wheel-rail interface. Its dynamic performance has a direct effect on the operational reliability of the locomotive and its components. This paper proposes a comprehensive locomotive-track coupled vertical dynamics model, in which the locomotive is driven by axle-hung motors. In this coupled dynamics model, the dynamic interactions between the gear transmission system and the other components, e.g. motor and wheelset, are considered based on the detailed analysis of its structural properties and working mechanism. Thus, the mechanical transmission system for power delivery from the motor to the wheelset via gear transmission is coupled with a traditional locomotive-track dynamics system via the wheel-rail contact interface and the gear mesh interface. This developed dynamics model enables investigations of the dynamic performance of the entire dynamics system under the excitations from the wheel-rail contact interface and/or the gear mesh interface. Dynamic interactions are demonstrated by numerical simulations using this dynamics model. The results indicate that both of the excitations from the wheel-rail contact interface and the gear mesh interface have a significant effect on the dynamic responses of the components in this coupled dynamics system.
Pan, Chun-Hsu; Tsai, Chia-Hua; Liu, Fon-Chang; Fan, Ming-Jen; Sheu, Ming-Jyh; Hsieh, Wen-Tsong; Wu, Chieh-Hsi
2013-04-01
Nanoparticle processing is implicated in enhancing bioactive or nutritional compound release from raw foods. The aim of the present study was to evaluate whether different particle processing might affect the lipid-lowering activity of Dioscorea pseudojaponica (DP) and to investigate whether DP could be a potential functional food for prevention of atherogenesis. Its possible molecular mechanisms were also evaluated. The results indicated that 50 mesh-size DP (50 mesh DP) particles exhibited stronger effects than nanoscale DP (nano DP) particles in terms of lowering the level of serum cholesterol as well as reducing the extent of fatty liver and aortic fatty streak. Moreover, both DP particle types, particularly 50 mesh DP, significantly activated AMPK (5'-adenosine monophosphate-activated protein kinase) and deactivated ACC (acetyl-CoA carboxylase), as demonstrated by the increased levels of both enzymes in their phosphorylated form. Coincidently, high-performance liquid chromatography (HPLC) analysis showed a higher content (P < 0.01) of dioscin, a known lipid-lowering compound, in 50 mesh DP than in nano DP. These results suggest that improper processing conditions will lead to the decomposition of bioactive components in yam. They also demonstrate for the first time that the lipid-lowering mechanisms of DP may occur through the AMPK-ACC pathway. © 2013 Society of Chemical Industry.
Hayashi, A
1991-02-01
The present experimental study was undertaken to evaluate the efficacy of combined latissimus dorsi muscle flap and soft Marlex mesh in the reconstruction of the trachea. Thirty-one mongrel dogs underwent a two-stage operation. In the first stage operation, they were divided into four groups for implanting a different prosthesis. A silicone rod was used as the core and this was rolled with soft Marlex mesh to make a prosthesis (Group A and B: without reinforce, Group C: reinforced by wrapping stainless steel mesh, Group D: reinforced with helical stain steel wire). The latissimus dorsi muscle flap was rolled circumferentially around the prosthesis and it was left in place for a period of 4 to 6 weeks. In the second stage operation, the long pedicled muscle flap with the biologically organized prosthesis was mobilized to be guided into the cervix, and the tracheal reconstruction was done with them following circumferential tracheal resection. In result, five of six dogs of group D survived more than 6 months after the replacement without anastomotic leakage or stenosis causing inflammatory granulation. Organization with neo-vascularity of the prosthesis at the time of the tracheal reconstruction was important firstly to avoid incurring complications concerning anastomosis and secondly for long-term stability of the healing and epithelialization of the prosthesis.
Carotenoids as Potential Antioxidant Agents in Stroke Prevention: A Systematic Review
Bahonar, Ahmad; Saadatnia, Mohammad; Khorvash, Fariborz; Maracy, Mohammadreza; Khosravi, Alireza
2017-01-01
Stroke and other cerebrovascular diseases are among the most common causes of death worldwide. Prevention of modifiable risk factors is a cost-effective approach to decrease the risk of stroke. Oxidative stress is regarded as the major flexible operative agent in ischemic brain damage. This review presents recent scientific advances in understanding the role of carotenoids as antioxidants in lowering stroke risk based on observational studies. We searched Medline using the following terms: (Carotenoids [MeSH] OR Carotenes [tiab] OR Carotene [tiab] OR “lycopene [Supplementary Concept]” [MeSH] OR lycopene [tiab] OR beta-Carotene [tiab]) AND (stroke [MeSH] OR stroke [tiab] OR “Cerebrovascular Accident” [tiab] OR “Cerebrovascular Apoplexy” [tiab] OR “Brain Vascular Accident” [tiab] OR “Cerebrovascular Stroke” [tiab]) AND (“oxidative stress” [MeSH] OR “oxidative stress”[tiab]). This search considered papers that had been published between 2000 and 2017. Recent studies indicated that high dietary intake of six main carotenoids (i.e., lycopene, <- and®-carotene, lutein, zeaxanthin, and astaxanthin) was associated with reduced risk of stroke and other cardiovascular outcomes. However, the main mechanism of the action of these nutrients was not identified, and multiple mechanisms except antioxidant activity were suggested to be involved in the observed beneficial effects. The dietary intake of six major carotenoids should be promoted as this may have a substantial positive effect on stroke prevention and stroke mortality reduction. PMID:28983399
Semi-automatic sparse preconditioners for high-order finite element methods on non-uniform meshes
NASA Astrophysics Data System (ADS)
Austin, Travis M.; Brezina, Marian; Jamroz, Ben; Jhurani, Chetan; Manteuffel, Thomas A.; Ruge, John
2012-05-01
High-order finite elements often have a higher accuracy per degree of freedom than the classical low-order finite elements. However, in the context of implicit time-stepping methods, high-order finite elements present challenges to the construction of efficient simulations due to the high cost of inverting the denser finite element matrix. There are many cases where simulations are limited by the memory required to store the matrix and/or the algorithmic components of the linear solver. We are particularly interested in preconditioned Krylov methods for linear systems generated by discretization of elliptic partial differential equations with high-order finite elements. Using a preconditioner like Algebraic Multigrid can be costly in terms of memory due to the need to store matrix information at the various levels. We present a novel method for defining a preconditioner for systems generated by high-order finite elements that is based on a much sparser system than the original high-order finite element system. We investigate the performance for non-uniform meshes on a cube and a cubed sphere mesh, showing that the sparser preconditioner is more efficient and uses significantly less memory. Finally, we explore new methods to construct the sparse preconditioner and examine their effectiveness for non-uniform meshes. We compare results to a direct use of Algebraic Multigrid as a preconditioner and to a two-level additive Schwarz method.
Delay in indexing articles published in major pharmacy practice journals.
Rodriguez, Ryan W
2014-02-15
The delay in time from entry in the PubMed database to indexing with medical subject heading (MeSH) terms for articles published in three major pharmacy practice journals was evaluated. In April 2013, MEDLINE data were retrieved for articles published in the American Journal of Health-System Pharmacy (AJHP), the Annals of Pharmacotherapy, and Pharmacotherapy between January 1, 2010, and December 31, 2011. Data collected for each article included the PubMed entry date, MeSH indexing date, and publication type. The PubMed entry date was defined as the Entrez date, the date the citation was added to the PubMed database. Medians and interquartile ranges (IQRs) were calculated for the time to indexing of articles and for the age of unindexed articles. The proportion of unindexed articles was also calculated. A total of 1626 publications were reviewed. Overall, the median time to indexing with MeSH terms was 114 days (IQR, 98-141 days): 107 days (IQR, 94-129 days) for AJHP, 131 days (IQR, 104-157 days) for Annals of Pharmacotherapy, and 114 days (IQR, 99-128 days) for Pharmacotherapy. The median age of unindexed articles was 807 days (IQR, 671-807 days). An analysis of three major pharmacy practice journals showed that the median time to indexing articles published in 2010 and 2011 was 114 days. While all articles from AJHP and Pharmacotherapy were indexed, 40 articles from Annals of Pharmacotherapy remained unindexed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dai, William W., E-mail: dai@lanl.gov; Scannapieco, Anthony J.
2015-11-01
A set of numerical schemes is developed for two- and three-dimensional time-dependent 3-T radiation diffusion equations in systems involving multi-materials. To resolve sub-cell structure, interface reconstruction is implemented within any cell that has more than one material. Therefore, the system of 3-T radiation diffusion equations is solved on two- and three-dimensional polyhedral meshes. The focus of the development is on the fully coupling between radiation and material, the treatment of nonlinearity in the equations, i.e., in the diffusion terms and source terms, treatment of the discontinuity across cell interfaces in material properties, the formulations for both transient and steady states,more » the property for large time steps, and second order accuracy in both space and time. The discontinuity of material properties between different materials is correctly treated based on the governing physics principle for general polyhedral meshes and full nonlinearity. The treatment is exact for arbitrarily strong discontinuity. The scheme is fully nonlinear for the full nonlinearity in the 3-T diffusion equations. Three temperatures are fully coupled and are updated simultaneously. The scheme is general in two and three dimensions on general polyhedral meshes. The features of the scheme are demonstrated through numerical examples for transient problems and steady states. The effects of some simplifications of numerical schemes are also shown through numerical examples, such as linearization, simple average of diffusion coefficient, and approximate treatment for the coupling between radiation and material.« less
Three-layer reconstruction for large defects of the anterior skull base.
Sinha, Uttam K; Johnson, Terence E; Crockett, Dennis; Vadapalli, Satish; Gruen, Peter
2002-03-01
To evaluate and discuss a three-layer rigid reconstruction technique for large anterior skull base defects. Prospective, nonrandomized, non-blinded. Tertiary teaching medical center. Twenty consecutive patients underwent craniofacial resection for a variety of pathology. All patients had large anterior cranial base defects involving the cribriform plate, fovea ethmoidalis, and medial portion of the roof of the orbit at least on one side. A few patients had more extensive defects involving both roof of the orbits, planum sphenoidale, and bones of the upper third of the face. The defects were reconstructed with a three-layer technique. A watertight seal was obtained with a pericranial flap separating the neurocranium from the viscerocranium. Rigid support was provided by bone grafts fixed to a titanium mesh, anchored laterally to the orbital roofs. All patients had a computed tomography scan of the skull on the first or second postoperative day. Patients were observed for immediate and long-term postoperative complications after such reconstruction. Postoperative computed tomography scans showed small pneumocephalus in all patients. It resolved spontaneously and did not produce neurologic deficits in any patient. There was no cerebrospinal fluid leak, hematoma, or infection. On long-term follow-up, exposures of bone graft or mesh, brain herniation, or transmission of brain pulsation to the eyes were not observed in any patient. Three-layer reconstruction using bone grafts, titanium mesh, and pericranial flap provides an alternative technique for repair of large anterior cranial base defects. It is safe and effective, and provides rigid protection to the brain.
Combined in vivo and ex vivo analysis of mesh mechanics in a porcine hernia model.
Kahan, Lindsey G; Lake, Spencer P; McAllister, Jared M; Tan, Wen Hui; Yu, Jennifer; Thompson, Dominic; Brunt, L Michael; Blatnik, Jeffrey A
2018-02-01
Hernia meshes exhibit variability in mechanical properties, and their mechanical match to tissue has not been comprehensively studied. We used an innovative imaging model of in vivo strain tracking and ex vivo mechanical analysis to assess effects of mesh properties on repaired abdominal walls in a porcine model. We hypothesized that meshes with dissimilar mechanical properties compared to native tissue would alter abdominal wall mechanics more than better-matched meshes. Seven mini-pigs underwent ventral hernia creation and subsequent open repair with one of two heavyweight polypropylene meshes. Following mesh implantation with attached radio-opaque beads, fluoroscopic images were taken at insufflation pressures from 5 to 30 mmHg on postoperative days 0, 7, and 28. At 28 days, animals were euthanized and ex vivo mechanical testing performed on full-thickness samples across repaired abdominal walls. Testing was conducted on 13 mini-pig controls, and on meshes separately. Stiffness and anisotropy (the ratio of stiffness in the transverse versus craniocaudal directions) were assessed. 3D reconstructions of repaired abdominal walls showed stretch patterns. As pressure increased, both meshes expanded, with no differences between groups. Over time, meshes contracted 17.65% (Mesh A) and 0.12% (Mesh B; p = 0.06). Mesh mechanics showed that Mesh A deviated from anisotropic native tissue more than Mesh B. Compared to native tissue, Mesh A was stiffer both transversely and craniocaudally. Explanted repaired abdominal walls of both treatment groups were stiffer than native tissue. Repaired tissue became less anisotropic over time, as mesh properties prevailed over native abdominal wall properties. This technique assessed 3D stretch at the mesh level in vivo in a porcine model. While the abdominal wall expanded, mesh-ingrown areas contracted, potentially indicating stresses at mesh edges. Ex vivo mechanics demonstrate that repaired tissue adopts mesh properties, suggesting that a better-matched mesh could reduce changes to abdominal wall mechanics.
Rieder, Erwin; Stoiber, Martin; Scheikl, Verena; Poglitsch, Marcus; Dal Borgo, Andrea; Prager, Gerhard; Schima, Heinrich
2011-01-01
Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks. Copyright © 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Liang, Mike K; Berger, Rachel L; Nguyen, Mylan Thi; Hicks, Stephanie C; Li, Linda T; Leong, Mimi
2014-10-01
Mesh reinforcement as part of open ventral hernia repair (OVHR) has become the standard of care. However, there is no consensus on the ideal type of mesh to use. In many clinical situations, surgeons are reluctant to use synthetic mesh. Options in these complicated OVHRs include suture repair or the use of biologic mesh such as porcine acellular dermal matrix (PADM). There has been a paucity of controlled studies reporting long-term outcomes with biologic meshes. We hypothesized that compared with synthetic mesh in OVHR, PADM is associated with fewer surgical site infections (SSI) but more seromas and recurrences. Additionally, compared with suture repair, we hypothesized that PADM is associated with fewer recurrences but more SSIs and seromas. A retrospective study was performed of all complicated OVHRs performed at a single institution from 2000-2011. All data were captured from the electronic medical records of the service network. Data were compared in two ways. First, patients who had OVHR with PADM were case-matched with patients having synthetic mesh repairs on the basis of incision class, Ventral Hernia Working Group (VHWG) grade, hernia size, American Society of Anesthesiologists (ASA) class, and emergency status. The PADM cases were also matched with suture repairs on the basis of incision class, hernia grade, duration of the operation, ASA class, and emergency status. Second, we developed a propensity score-adjusted multi-variable logistic regression model utilizing internal resampling to identify predictors of primary outcomes of the overall cohort. The U.S. Centers for Disease Control and Prevention (CDC) definition of SSI was utilized; seromas and recurrences were defined and tracked similarly for all patients. Data were analyzed using the McNemar, X(2), paired two-tailed Student t, or Mann-Whitney U test as appropriate. A total of 449 complicated OVHR cases were reviewed for a median follow up of 61 mos (range 1-143 mos): 94 patients had PADM repairs, whereas 154 patients underwent synthetic mesh repairs, and 201 had suture repairs. The 40 PADM repairs were matched to synthetic repairs and 59 were matched to suture repairs. The PADM repairs that could not be well matched (n=54 unmatched for synthetic repairs, 35 unmatched for suture repairs) were characterized generally by larger hernias, VHWG grades of 3 or 4, and incision class 3 or 4 with longer operative durations and more ASA class 4 cases. The patients were well matched. Comparing PADM with synthetic mesh, there was no difference in SSI (20% vs. 35%; p=0.29), seromas (32.5% vs. 15%; p=0.17), mesh explantations (5% vs. 15%, p=0.28), readmissions within 90 d (37.5% vs. 45%; p=1.00), or recurrence (8.5% vs. 22.5%; p=0.15). Compared with suture repair, patients with PADM had fewer recurrences (11.9% vs. 33.9%; p<0.01) and more seromas (32.2% vs. 10.2%; p=0.02), but a similar number of SSIs (23.7% vs. 39.0%; p=0.19) and 90-d readmissions (35.6% vs. 39.0%; p=0.88). Propensity score-adjusted multi-variable logistic regression of the entire cohort corroborated the results of the case-matched patients. The PADM repair of complicated OVHR resulted in fewer recurrences, more seromas, and no difference in SSI compared with suture repair. Although no reduction in SSI was identified with the use of PADM rather than synthetic mesh or suture for OVHR, the meaning of this finding is unclear, as this case-controlled study was underpowered and limited by selection bias. According to our data, 280 patients would have been needed to identify a clinically significant difference in the primary outcome of SSI as well as secondary outcomes of mesh explantation and recurrence (α=0.05; β=0.20). A randomized trial is warranted to compare PADM with synthetic mesh in complicated OVHR.
Bovine versus porcine acellular dermal matrix for complex abdominal wall reconstruction.
Clemens, Mark W; Selber, Jesse C; Liu, Jun; Adelman, David M; Baumann, Donald P; Garvey, Patrick B; Butler, Charles E
2013-01-01
Abdominal wall reconstruction with bioprosthetic mesh is associated with lower rates of mesh infection, fistula formation, and mesh explantation than reconstruction with synthetic mesh. The authors directly compared commonly used bioprosthetic meshes in terms of clinical outcomes and complications. A database of consecutive patients who underwent abdominal wall reconstruction with porcine or bovine acellular dermal matrix and midline musculofascial closure at their institution between January of 2008 and March of 2011 was reviewed. Surgical outcomes were compared. One hundred twenty patients were identified who underwent a nonbridged, inlay abdominal wall reconstruction with porcine [69 patients (57.5 percent)] or bovine acellular dermal matrix (51 patients (42.5 percent)]. The mean follow-up time was 21.0 ± 9.9 months. The overall complication rate was 36.6 percent; the porcine matrix group had a significantly higher complication rate (44.9 percent) than the bovine matrix group (25.5 percent; p = 0.04) and statistically equivalent surgical complications (29.2 percent versus 21.6 percent; p = 0.34). There were no significant differences in rates of recurrent hernia (2.9 percent versus 3.9 percent; p = 0.99) or bulge (7.2 percent versus 0 percent; p = 0.07). However, the rate of intraoperative adverse events in the porcine matrix group [seven events (10.1 percent)] was significantly higher than that in the bovine matrix group (0 percent; p = 0.02). In patients who undergo complex abdominal wall reconstruction, both bovine and porcine acellular dermal matrix are associated with similar rates of postoperative surgical complications and appear to result in similar outcomes. Porcine acellular dermal matrix may be prone to intraoperative device failure. Therapeutic, III.
Joo, Young Min; Choe, Jin Ho
2010-01-01
Purpose We compared the efficacy and safety of two minimally invasive sling procedures used to treat female stress urinary incontinence (SUI), tension-free vaginal tape (TVT) SECUR® and CureMesh®, and assessed the 1-year surgical outcomes. Materials and Methods Sixty women with SUI were assigned to undergo either the TVT SECUR (n=38) or CureMesh (n=22) procedures between April 2007 and June 2008. Patients were monitored via outpatient visits at 1 month, 3 months, and 1 year after surgery. The efficacy of these procedures was evaluated by the cough test or by a urodynamic study. At these postoperative visits, the patients also completed several questionnaires, including incontinence quality of life, patient's perception of urgency severity, the scored form of the Bristol Female Lower Urinary Tract Symptoms, visual analog scale, and questions about perceived benefit, satisfaction, and willingness to undergo the same operation again. The objective cure rate was defined as no leakage during the cough test with a full bladder. The subjective cure rate was evaluated by self-assessment of goal achievement performed 1 year postoperatively. Results The two groups were similar in preoperative characteristics and urodynamic parameters. The objective cure rates were similar between TVT SECUR and CureMesh (68.4% vs. 77.3%). All respondents reported improvement after surgery. There were no intra-operative complications. Conclusions Our results showed that the TVT SECUR and CureMesh procedures are both safe and simple to perform and have no significant differences in efficacy. Comparative studies with long-term follow-up are warranted to determine the true efficacy of these procedures. PMID:20495697
Le Normand, L; Deffieux, X; Donon, L; Fatton, B; Cour, F
2016-07-01
The use of prosthetic surgery by vaginal route has been widely used to try to reduce the risk of prolapse recurrence in the surgical treatment of vaginal cystoceles. Specific complications including type of erosion have led to randomized studies comparing surgery by vaginal route with and without use of Mesh. This work is based on a systematic review of the literature (PubMed, Medline, Cochrane Library, Cochrane database of systemactic reviews, EMBASE) for meta-analyzes, randomized trials, registries, literature reviews, controlled studies and major not controlled studies, published on the subject. Its implementation has followed the methodology of the HAS on the recommendations for clinical practice, with a scientific argument (with the level of evidence, NP) and a recommendation grade (A, B, C, and professional agreement (AP)). The use of inter-vesicovaginal synthetic mesh improves the anatomical result compared to the autologous surgery for the treatment of cystocele (NP1). However, there is no difference in the functional outcome and there is an increase in the number of reoperations related to specific complications, including vaginal erosions. If the use of inter-vesicovaginal synthetic mesh improves the anatomical result compared to the autologous surgery for the treatment of cystocele (NP1), no difference in functional outcome and the increased number of related reoperations specific complications including vaginal erosions, do not argue for the systematic use of mesh in the treatment of primary cystocele. It must be discussed case by case basis taking into account a risk-benefit uncertain at long-term (grade B). Its use should be supported by additional studies focused on specific populations at risk of recurrence. © 2016 Published by Elsevier Masson SAS. © 2016 Elsevier Masson SAS. Tous droits réservés.
Fekete, Zoltán; Körösi, Szilvia; Németh, Gábor
2018-03-01
The prevalence of pelvic organ prolapse (POP) with aging is escalating alarmingly, and now becoming a growing epidemic among the elderly. Synthetic transvaginal mesh (TVM) has been employed with increasing popularity in the treatment of POP until the end of the last decade. After the U.S. Drug and Food Administration (FDA) warnings in the years 2008 and 2011, the number of vaginal mesh operations has decreased dramatically. The aim of the study was to evaluate and compare the anti-POP effectivity, the anti-stress incontinence (anti-SUI) efficacy, and the late (36 months) post-operative complications of the anterior vaginoplasty and the TVM operations. We analysed the clinical data from 120 patients with stage II-III anterior prolapse and concomitant SUI who had undergone surgery at a tertiary referral centre in Hungary between January 2013 and January 2014. Sixty patients underwent Kelly-Stoeckel vaginoplasty and the other 60 cases had TVM operation. The surgical complications were classified using the Clavien-Dindo (CD) classification system. The anti-POP (91.6% vs. 63.3%; p<0.001) and the anti-SUI efficacy (90% vs. 55%, p<0.001) were significantly higher in the TVM group than in the vaginoplasty group, while the overall extrusion rate was found 8.3% after a 3-year follow-up. The Clavien-Dindo score (CD) proved that the early post-operative complication profile was similar among the TVM patients as compared to the vaginoplasty group (p = 0.405). Vaginal mesh surgery represents an effective procedure for prolapse and concomitant SUI with a decreased risk of short- and long-term complications. Orv Hetil. 2018; 159(10): 397-404.
Lederhuber, Hans; Stiede, Franziska; Axer, Stephan; Dahlstrand, Ursula
2017-11-01
The issue of mesh fixation in endoscopic inguinal hernia repair is frequently debated and still no conclusive data exist on differences between methods regarding long-term outcome and postoperative complications. The quantity of trials and the simultaneous lack of high-quality evidence raise the question how future trials should be planned. PubMed, EMBASE and the Cochrane Library were searched, using the filters "randomised clinical trials" and "humans". Trials that compared one method of mesh fixation with another fixation method or with non-fixation in endoscopic inguinal hernia repair were eligible. To be included, the trial was required to have assessed at least one of the following primary outcome parameters: recurrence; surgical site infection; chronic pain; or quality-of-life. Fourteen trials assessing 2161 patients and 2562 hernia repairs were included. Only two trials were rated as low risk for bias. Eight trials evaluated recurrence or surgical site infection; none of these could show significant differences between methods of fixation. Two of 11 trials assessing chronic pain described significant differences between methods of fixation. One of two trials evaluating quality-of-life showed significant differences between fixation methods in certain functions. High-quality evidence for differences between the assessed mesh fixation techniques is still lacking. From a socioeconomic and ethical point of view, it is necessary that future trials will be properly designed. As small- and medium-sized single-centre trials have proven unable to find answers, register studies or multi-centre studies with an evident focus on methodology and study design are needed in order to answer questions about mesh fixation in inguinal hernia repair.
NASA Astrophysics Data System (ADS)
Pathak, Harshavardhana S.; Shukla, Ratnesh K.
2016-08-01
A high-order adaptive finite-volume method is presented for simulating inviscid compressible flows on time-dependent redistributed grids. The method achieves dynamic adaptation through a combination of time-dependent mesh node clustering in regions characterized by strong solution gradients and an optimal selection of the order of accuracy and the associated reconstruction stencil in a conservative finite-volume framework. This combined approach maximizes spatial resolution in discontinuous regions that require low-order approximations for oscillation-free shock capturing. Over smooth regions, high-order discretization through finite-volume WENO schemes minimizes numerical dissipation and provides excellent resolution of intricate flow features. The method including the moving mesh equations and the compressible flow solver is formulated entirely on a transformed time-independent computational domain discretized using a simple uniform Cartesian mesh. Approximations for the metric terms that enforce discrete geometric conservation law while preserving the fourth-order accuracy of the two-point Gaussian quadrature rule are developed. Spurious Cartesian grid induced shock instabilities such as carbuncles that feature in a local one-dimensional contact capturing treatment along the cell face normals are effectively eliminated through upwind flux calculation using a rotated Hartex-Lax-van Leer contact resolving (HLLC) approximate Riemann solver for the Euler equations in generalized coordinates. Numerical experiments with the fifth and ninth-order WENO reconstructions at the two-point Gaussian quadrature nodes, over a range of challenging test cases, indicate that the redistributed mesh effectively adapts to the dynamic flow gradients thereby improving the solution accuracy substantially even when the initial starting mesh is non-adaptive. The high adaptivity combined with the fifth and especially the ninth-order WENO reconstruction allows remarkably sharp capture of discontinuous propagating shocks with simultaneous resolution of smooth yet complex small scale unsteady flow features to an exceptional detail.
Does topical rifampicin reduce the risk of surgical field infection in hernia repair?
Kahramanca, Şahin; Kaya, Oskay; Azılı, Cem; Celep, Bahadır; Gökce, Emre; Küçükpınar, Tevfik
2013-01-01
Objective: Inguinal hernia operations are common procedures in general surgery. There have been many approaches in the historical development of hernia repair; tension free repair with mesh being the most commonly used technique today. Although it is a clean wound, antibiotic use is still controversial due to concerns about infection related to synthetic mesh. We aimed to determine the probable role of topical rifampicin in patients with tension-free hernia repair and mesh support. Material and Methods: The charts of patients who underwent tension-free inguinal hernia repair were retrospectively analyzed. Information and operative notes on patients, in whom synthetic materials were used, were identified. The patients were divided into two groups, placebo group (G1) and patients with application of topical rifampicin on the mesh (G2). Infection rates between the groups in the early postoperative period were compared. Results: The mean age of the 278 patients who were included in the study was 49.6±15.39 and the female/male ratio was 10/268. There were recurrent hernias in four patients and superficial wound infections in 22 patients in the early period. One patient had testicle torsion and underwent an orchiectomy. There were no significant differences between the groups in terms of age and gender. The types of hernia and body mass index were homogenous between the two groups. In the early postoperative period the infection rates were 16/144 (11.1%) and 6/134 (4.48%) in the groups, respectively, with the difference being statistically significant (p=0.041). Conclusion: We suggest that applying rifampicin locally can decrease surgical site infection in hernia operations where meshes are used. PMID:25931846
Forwarding techniques for IP fragmented packets in a real 6LoWPAN network.
Ludovici, Alessandro; Calveras, Anna; Casademont, Jordi
2011-01-01
Wireless Sensor Networks (WSNs) are attracting more and more interest since they offer a low-cost solution to the problem of providing a means to deploy large sensor networks in a number of application domains. We believe that a crucial aspect to facilitate WSN diffusion is to make them interoperable with external IP networks. This can be achieved by using the 6LoWPAN protocol stack. 6LoWPAN enables the transmission of IPv6 packets over WSNs based on the IEEE 802.15.4 standard. IPv6 packet size is considerably larger than that of IEEE 802.15.4 data frame. To overcome this problem, 6LoWPAN introduces an adaptation layer between the network and data link layers, allowing IPv6 packets to be adapted to the lower layer constraints. This adaptation layer provides fragmentation and header compression of IP packets. Furthermore, it also can be involved in routing decisions. Depending on which layer is responsible for routing decisions, 6LoWPAN divides routing in two categories: mesh under if the layer concerned is the adaptation layer and route over if it is the network layer. In this paper we analyze different routing solutions (route over, mesh under and enhanced route over) focusing on how they forward fragments. We evaluate their performance in terms of latency and energy consumption when transmitting IP fragmented packets. All the tests have been performed in a real 6LoWPAN implementation. After consideration of the main problems in forwarding of mesh frames in WSN, we propose and analyze a new alternative scheme based on mesh under, which we call controlled mesh under.
Forwarding Techniques for IP Fragmented Packets in a Real 6LoWPAN Network
Ludovici, Alessandro; Calveras, Anna; Casademont, Jordi
2011-01-01
Wireless Sensor Networks (WSNs) are attracting more and more interest since they offer a low-cost solution to the problem of providing a means to deploy large sensor networks in a number of application domains. We believe that a crucial aspect to facilitate WSN diffusion is to make them interoperable with external IP networks. This can be achieved by using the 6LoWPAN protocol stack. 6LoWPAN enables the transmission of IPv6 packets over WSNs based on the IEEE 802.15.4 standard. IPv6 packet size is considerably larger than that of IEEE 802.15.4 data frame. To overcome this problem, 6LoWPAN introduces an adaptation layer between the network and data link layers, allowing IPv6 packets to be adapted to the lower layer constraints. This adaptation layer provides fragmentation and header compression of IP packets. Furthermore, it also can be involved in routing decisions. Depending on which layer is responsible for routing decisions, 6LoWPAN divides routing in two categories: mesh under if the layer concerned is the adaptation layer and route over if it is the network layer. In this paper we analyze different routing solutions (route over, mesh under and enhanced route over) focusing on how they forward fragments. We evaluate their performance in terms of latency and energy consumption when transmitting IP fragmented packets. All the tests have been performed in a real 6LoWPAN implementation. After consideration of the main problems in forwarding of mesh frames in WSN, we propose and analyze a new alternative scheme based on mesh under, which we call controlled mesh under. PMID:22346615
Discretization-dependent model for weakly connected excitable media
NASA Astrophysics Data System (ADS)
Arroyo, Pedro André; Alonso, Sergio; Weber dos Santos, Rodrigo
2018-03-01
Pattern formation has been widely observed in extended chemical and biological processes. Although the biochemical systems are highly heterogeneous, homogenized continuum approaches formed by partial differential equations have been employed frequently. Such approaches are usually justified by the difference of scales between the heterogeneities and the characteristic spatial size of the patterns. Under different conditions, for example, under weak coupling, discrete models are more adequate. However, discrete models may be less manageable, for instance, in terms of numerical implementation and mesh generation, than the associated continuum models. Here we study a model to approach discreteness which permits the computer implementation on general unstructured meshes. The model is cast as a partial differential equation but with a parameter that depends not only on heterogeneities sizes, as in the case of quasicontinuum models, but also on the discretization mesh. Therefore, we refer to it as a discretization-dependent model. We validate the approach in a generic excitable media that simulates three different phenomena: the propagation of action membrane potential in cardiac tissue, in myelinated axons of neurons, and concentration waves in chemical microemulsions.
A third-order gas-kinetic CPR method for the Euler and Navier-Stokes equations on triangular meshes
NASA Astrophysics Data System (ADS)
Zhang, Chao; Li, Qibing; Fu, Song; Wang, Z. J.
2018-06-01
A third-order accurate gas-kinetic scheme based on the correction procedure via reconstruction (CPR) framework is developed for the Euler and Navier-Stokes equations on triangular meshes. The scheme combines the accuracy and efficiency of the CPR formulation with the multidimensional characteristics and robustness of the gas-kinetic flux solver. Comparing with high-order finite volume gas-kinetic methods, the current scheme is more compact and efficient by avoiding wide stencils on unstructured meshes. Unlike the traditional CPR method where the inviscid and viscous terms are treated differently, the inviscid and viscous fluxes in the current scheme are coupled and computed uniformly through the kinetic evolution model. In addition, the present scheme adopts a fully coupled spatial and temporal gas distribution function for the flux evaluation, achieving high-order accuracy in both space and time within a single step. Numerical tests with a wide range of flow problems, from nearly incompressible to supersonic flows with strong shocks, for both inviscid and viscous problems, demonstrate the high accuracy and efficiency of the present scheme.
Efficient low-bit-rate adaptive mesh-based motion compensation technique
NASA Astrophysics Data System (ADS)
Mahmoud, Hanan A.; Bayoumi, Magdy A.
2001-08-01
This paper proposes a two-stage global motion estimation method using a novel quadtree block-based motion estimation technique and an active mesh model. In the first stage, motion parameters are estimated by fitting block-based motion vectors computed using a new efficient quadtree technique, that divides a frame into equilateral triangle blocks using the quad-tree structure. Arbitrary partition shapes are achieved by allowing 4-to-1, 3-to-1 and 2-1 merge/combine of sibling blocks having the same motion vector . In the second stage, the mesh is constructed using an adaptive triangulation procedure that places more triangles over areas with high motion content, these areas are estimated during the first stage. finally the motion compensation is achieved by using a novel algorithm that is carried by both the encoder and the decoder to determine the optimal triangulation of the resultant partitions followed by affine mapping at the encoder. Computer simulation results show that the proposed method gives better performance that the conventional ones in terms of the peak signal-to-noise ration (PSNR) and the compression ratio (CR).
Radiation Coupling with the FUN3D Unstructured-Grid CFD Code
NASA Technical Reports Server (NTRS)
Wood, William A.
2012-01-01
The HARA radiation code is fully-coupled to the FUN3D unstructured-grid CFD code for the purpose of simulating high-energy hypersonic flows. The radiation energy source terms and surface heat transfer, under the tangent slab approximation, are included within the fluid dynamic ow solver. The Fire II flight test, at the Mach-31 1643-second trajectory point, is used as a demonstration case. Comparisons are made with an existing structured-grid capability, the LAURA/HARA coupling. The radiative surface heat transfer rates from the present approach match the benchmark values within 6%. Although radiation coupling is the focus of the present work, convective surface heat transfer rates are also reported, and are seen to vary depending upon the choice of mesh connectivity and FUN3D ux reconstruction algorithm. On a tetrahedral-element mesh the convective heating matches the benchmark at the stagnation point, but under-predicts by 15% on the Fire II shoulder. Conversely, on a mixed-element mesh the convective heating over-predicts at the stagnation point by 20%, but matches the benchmark away from the stagnation region.
Method and system for mesh network embedded devices
NASA Technical Reports Server (NTRS)
Wang, Ray (Inventor)
2009-01-01
A method and system for managing mesh network devices. A mesh network device with integrated features creates an N-way mesh network with a full mesh network topology or a partial mesh network topology.
Convergence study of global meshing on enamel-cement-bracket finite element model
NASA Astrophysics Data System (ADS)
Samshuri, S. F.; Daud, R.; Rojan, M. A.; Basaruddin, K. S.; Abdullah, A. B.; Ariffin, A. K.
2017-09-01
This paper presents on meshing convergence analysis of finite element (FE) model to simulate enamel-cement-bracket fracture. Three different materials used in this study involving interface fracture are concerned. Complex behavior ofinterface fracture due to stress concentration is the reason to have a well-constructed meshing strategy. In FE analysis, meshing size is a critical factor that influenced the accuracy and computational time of analysis. The convergence study meshing scheme involving critical area (CA) and non-critical area (NCA) to ensure an optimum meshing sizes are acquired for this FE model. For NCA meshing, the area of interest are at the back of enamel, bracket ligature groove and bracket wing. For CA meshing, area of interest are enamel area close to cement layer, the cement layer and bracket base. The value of constant NCA meshing tested are meshing size 1 and 0.4. The value constant CA meshing tested are 0.4 and 0.1. Manipulative variables are randomly selected and must abide the rule of NCA must be higher than CA. This study employed first principle stresses due to brittle failure nature of the materials used. Best meshing size are selected according to convergence error analysis. Results show that, constant CA are more stable compare to constant NCA meshing. Then, 0.05 constant CA meshing are tested to test the accuracy of smaller meshing. However, unpromising result obtained as the errors are increasing. Thus, constant CA 0.1 with NCA mesh of 0.15 until 0.3 are the most stable meshing as the error in this region are lowest. Convergence test was conducted on three selected coarse, medium and fine meshes at the range of NCA mesh of 0.15 until 3 and CA mesh area stay constant at 0.1. The result shows that, at coarse mesh 0.3, the error are 0.0003% compare to 3% acceptable error. Hence, the global meshing are converge as the meshing size at CA 0.1 and NCA 0.15 for this model.
Oh, Sam S.; Foreman, Marilyn G.; Celedón, Juan C.
2015-01-01
A key objective of the 1993 National Institutes of Health (NIH) Revitalization Act was to ensure inclusion of minorities in clinical research. We conducted a literature search for the period from 1993 to 2013 to examine whether racial/ethnic minorities are adequately represented in published research studies of pulmonary diseases, particularly NIH-funded studies. We found a marked underrepresentation of minorities in published clinical research on pulmonary diseases. Over the last 20 years, inclusion of members of racial or ethnic minority groups was reported (in MeSH terms, journal titles, and MEDLINE fields) in less than 5% of all NIH-funded published studies of respiratory diseases. Although a secondary analysis revealed that a larger proportion of NIH-funded studies included any minorities, this proportional increment mostly resulted from studies including relatively small numbers of minorities (which precludes robust race- or ethnic-specific analyses). Underrepresentation or exclusion of minorities from NIH-funded studies is likely due to multiple reasons, including insufficient education and training on designing and implementing population-based studies of minorities, inadequate motivation or incentives to overcome challenges in the recruitment and retention of sufficient numbers of members of racial/ethnic minorities, underrepresentation of minorities among respiratory scientists in academic medical centers, and a dearth of successful partnerships between academic medical centers and underrepresented communities. This problem could be remedied by implementing short-, medium-, and long-term strategies, such as creating incentives to conduct minority research, ensuring fair review of grant applications focusing on minorities, developing the careers of minority scientists, and facilitating and valuing research on minorities by investigators of all backgrounds. PMID:25584658
Burchard, Esteban G; Oh, Sam S; Foreman, Marilyn G; Celedón, Juan C
2015-03-01
A key objective of the 1993 National Institutes of Health (NIH) Revitalization Act was to ensure inclusion of minorities in clinical research. We conducted a literature search for the period from 1993 to 2013 to examine whether racial/ethnic minorities are adequately represented in published research studies of pulmonary diseases, particularly NIH-funded studies. We found a marked underrepresentation of minorities in published clinical research on pulmonary diseases. Over the last 20 years, inclusion of members of racial or ethnic minority groups was reported (in MeSH terms, journal titles, and MEDLINE fields) in less than 5% of all NIH-funded published studies of respiratory diseases. Although a secondary analysis revealed that a larger proportion of NIH-funded studies included any minorities, this proportional increment mostly resulted from studies including relatively small numbers of minorities (which precludes robust race- or ethnic-specific analyses). Underrepresentation or exclusion of minorities from NIH-funded studies is likely due to multiple reasons, including insufficient education and training on designing and implementing population-based studies of minorities, inadequate motivation or incentives to overcome challenges in the recruitment and retention of sufficient numbers of members of racial/ethnic minorities, underrepresentation of minorities among respiratory scientists in academic medical centers, and a dearth of successful partnerships between academic medical centers and underrepresented communities. This problem could be remedied by implementing short-, medium-, and long-term strategies, such as creating incentives to conduct minority research, ensuring fair review of grant applications focusing on minorities, developing the careers of minority scientists, and facilitating and valuing research on minorities by investigators of all backgrounds.
Deek, Hiba; Newton, Phillip; Sheerin, Noella; Noureddine, Samar; Davidson, Patricia M
2014-11-01
Contrast media induced nephropathy (CIN) is a sudden compromise of renal function 24-48 h after administering contrast medium during a CT scan or angiography. CIN accounts for 10% of hospital acquired renal failure and is ranked the third cause of acquiring this condition. Identifying patients at risk through proper screening can reduce the occurrence of this condition. This review paper aims to critique current evidence, provide a better understanding of CIN, inform nursing practice and make recommendations for bedside nurses and future research. An integrative review of the literature was made using the key terms: "contrast media", "nephritis", "nephropathy", "contrast media induced nephropathy scores", "acute kidney failure", "acute renal failure" and "acute kidney injury". MeSH key terms used in some databases were: "prevention and control", "acute kidney failure" and "treatment". Databases searched included Medline, CINAHL and Academic Search Complete, and references of relevant articles were also assessed. The search included all articles between the years 2000 and 2013. Sixty-seven articles were obtained as a result of the search, including RCTs, systematic reviews, and retrospective studies. Contrast media induced nephropathy is an iatrogenic complication occurring secondary to diagnostic or therapeutic procedures. At times it is unavoidable but a systematic method of risk assessment should be adopted to identify high risk patients for tailored and targeted approaches to management interventions. As the use of contrast media is increasing for diagnostic purposes, it is important that nurses be aware of the risk factors for CIN, identify and monitor high risk patients to prevent deterioration in renal function when possible. Copyright © 2014 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Method and apparatus for connecting finite element meshes and performing simulations therewith
Dohrmann, Clark R.; Key, Samuel W.; Heinstein, Martin W.
2003-05-06
The present invention provides a method of connecting dissimilar finite element meshes. A first mesh, designated the master mesh, and a second mesh, designated the slave mesh, each have interface surfaces proximal the other. Each interface surface has a corresponding interface mesh comprising a plurality of interface nodes. Each slave interface node is assigned new coordinates locating the interface node on the interface surface of the master mesh. The slave interface surface is further redefined to be the projection of the slave interface mesh onto the master interface surface.
A methodology for quadrilateral finite element mesh coarsening
Staten, Matthew L.; Benzley, Steven; Scott, Michael
2008-03-27
High fidelity finite element modeling of continuum mechanics problems often requires using all quadrilateral or all hexahedral meshes. The efficiency of such models is often dependent upon the ability to adapt a mesh to the physics of the phenomena. Adapting a mesh requires the ability to both refine and/or coarsen the mesh. The algorithms available to refine and coarsen triangular and tetrahedral meshes are very robust and efficient. However, the ability to locally and conformally refine or coarsen all quadrilateral and all hexahedral meshes presents many difficulties. Some research has been done on localized conformal refinement of quadrilateral and hexahedralmore » meshes. However, little work has been done on localized conformal coarsening of quadrilateral and hexahedral meshes. A general method which provides both localized conformal coarsening and refinement for quadrilateral meshes is presented in this paper. This method is based on restructuring the mesh with simplex manipulations to the dual of the mesh. Finally, this method appears to be extensible to hexahedral meshes in three dimensions.« less
Adaptive Skin Meshes Coarsening for Biomolecular Simulation
Shi, Xinwei; Koehl, Patrice
2011-01-01
In this paper, we present efficient algorithms for generating hierarchical molecular skin meshes with decreasing size and guaranteed quality. Our algorithms generate a sequence of coarse meshes for both the surfaces and the bounded volumes. Each coarser surface mesh is adaptive to the surface curvature and maintains the topology of the skin surface with guaranteed mesh quality. The corresponding tetrahedral mesh is conforming to the interface surface mesh and contains high quality tetrahedral that decompose both the interior of the molecule and the surrounding region (enclosed in a sphere). Our hierarchical tetrahedral meshes have a number of advantages that will facilitate fast and accurate multigrid PDE solvers. Firstly, the quality of both the surface triangulations and tetrahedral meshes is guaranteed. Secondly, the interface in the tetrahedral mesh is an accurate approximation of the molecular boundary. In particular, all the boundary points lie on the skin surface. Thirdly, our meshes are Delaunay meshes. Finally, the meshes are adaptive to the geometry. PMID:21779137
NASA Technical Reports Server (NTRS)
Vemaganti, Gururaja R.
1994-01-01
This report presents computations for the Type 4 shock-shock interference flow under laminar and turbulent conditions using unstructured grids. Mesh adaptation was accomplished by remeshing, refinement, and mesh movement. Two two-equation turbulence models were used to analyze turbulent flows. The mean flow governing equations and the turbulence governing equations are solved in a coupled manner. The solution algorithm and the details pertaining to its implementation on unstructured grids are described. Computations were performed at two different freestream Reynolds numbers at a freestream Mach number of 11. Effects of the variation in the impinging shock location are studied. The comparison of the results in terms of wall heat flux and wall pressure distributions is presented.
User Manual for the PROTEUS Mesh Tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Micheal A.; Shemon, Emily R.
2015-06-01
This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a givenmore » mesh tool (such as .axial or .merge) can be used as “mesh” input for any of the mesh tools discussed in this manual.« less
Search strings for the study of putative occupational determinants of disease
Mattioli, Stefano; Zanardi, Francesca; Baldasseroni, Alberto; Schaafsma, Frederieke; Cooke, Robin MT; Mancini, Gianpiero; Fierro, Mauro; Santangelo, Chiara; Farioli, Andrea; Fucksia, Serenella; Curti, Stefania; Verbeek, Jos
2010-01-01
Objective To identify efficient PubMed search strategies to retrieve articles regarding putative occupational determinants of conditions not generally considered to be work related. Methods Based on MeSH definitions and expert knowledge, we selected as candidate search terms the four MeSH terms describing ‘occupational disease’, ‘occupational exposure’, ‘occupational health’ and ‘occupational medicine’ (DEHM) alongside 22 other promising terms. We first explored overlaps between the candidate terms in PubMed. Using random samples of abstracts retrieved by each term, we estimated the proportions of articles containing potentially pertinent information regarding occupational aetiology in order to formulate two search strategies (one more ‘specific’, one more ‘sensitive’). We applied these strategies to retrieve information on the possible occupational aetiology of meningioma, pancreatitis and atrial fibrillation. Results Only 20.3% of abstracts were retrieved by more than one DEHM term. The more ‘specific’ search string was based on the combination of terms that yielded the highest proportion (40%) of potentially pertinent abstracts. The more ‘sensitive’ string was based on the use of broader search fields and additional coverage provided by other search terms under study. Using the specific string, the numbers of abstracts needed to read to find one potentially pertinent article were 1.2 for meningioma, 1.9 for pancreatitis and 1.8 for atrial fibrillation. Using the sensitive strategy, the numbers needed to read were 4.4 for meningioma, 8.9 for pancreatitis and 10.5 for atrial fibrillation. Conclusions The proposed strings could help health care professionals explore putative occupational aetiology for diseases that are not generally thought to be work related. PMID:19819858
Shaukat, Noureen; Jaleel, Farhat; Jawaid, Masood; Zulfiqar, Imrana
2018-01-01
Chronic pain occurs in 20-30% of patients after hernia surgery. As a consequence of this chronic pain, almost one third of patients have limitations in daily activities. Frequency and severity of this pain varies with different techniques of hernia repair. The objective of this study was to compare polypropylene suture and skin staples for securing mesh in uncomplicated ventral hernioplasty in terms of acute and chronic postoperative pain and to compare the time taken for mesh fixation between polypropylene sutures and skin stapler in ventral hernioplasty. This study was conducted in Surgery Department of Dow University Hospital, Dow University of Health Sciences, Ojha Campus and included 53 patients from Jan 2015 to Dec 2016, after taking informed consent. All patients were operated under general anesthesia by the same surgical team. Patients were randomized into two groups; in one group mesh fixed with 2/0 polypropylene suture while in other group mesh stapler was used. Time taken to apply mesh was noted in minutes from laying the mesh over anterior rectus sheath to completion of fixation by either method. The severity of post-operative pain was measured with VAS (1-10) after one week, one month and after one year after surgery. Data was analysed using SPSS version 17. Patient characteristics and operative outcome were similar in the two groups and statistically non-significant in both. Early postoperative pain was more after suture fixation but it was not statistically significant. Mean ± SD pain score was after one week 3.47±2.7 after sutures while 2.91±1.88 after stapler. After four weeks, 0.40±0.49 after suture while 0.35±0.48 after stapler fixation. In both study groups 30-34% of the patients felt some pain in follow-up after one year. Severity of pain was 0.60±0.62 after suture while 1.65±1.94 after stapler fixation which is statistically significant as well (p<0.007). Mean operative time was 15.33±6.33 minutes for suture fixation while 1.56±0.41 minutes for fixation by staples, p-value < 0.001. The method of fixation does not appear to cause significant difference in early post-operative pain but chronic pain is more after stapler fixation of mesh. However, operative time was reduced significantly in staple fixation group as compared to suture fixation group.
User Manual for the PROTEUS Mesh Tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Micheal A.; Shemon, Emily R
2016-09-19
PROTEUS is built around a finite element representation of the geometry for visualization. In addition, the PROTEUS-SN solver was built to solve the even-parity transport equation on a finite element mesh provided as input. Similarly, PROTEUS-MOC and PROTEUS-NEMO were built to apply the method of characteristics on unstructured finite element meshes. Given the complexity of real world problems, experience has shown that using commercial mesh generator to create rather simple input geometries is overly complex and slow. As a consequence, significant effort has been put into place to create multiple codes that help assist in the mesh generation and manipulation.more » There are three input means to create a mesh in PROTEUS: UFMESH, GRID, and NEMESH. At present, the UFMESH is a simple way to generate two-dimensional Cartesian and hexagonal fuel assembly geometries. The UFmesh input allows for simple assembly mesh generation while the GRID input allows the generation of Cartesian, hexagonal, and regular triangular structured grid geometry options. The NEMESH is a way for the user to create their own mesh or convert another mesh file format into a PROTEUS input format. Given that one has an input mesh format acceptable for PROTEUS, we have constructed several tools which allow further mesh and geometry construction (i.e. mesh extrusion and merging). This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a given mesh tool (such as .axial or .merge) can be used as “mesh” input for any of the mesh tools discussed in this manual.« less
Forrester, Joseph D; Gomez, Carlos A; Forrester, Jared A; Nguyen, Mike; Gregg, David; Deresinski, Stan; Banaei, Niaz; Weiser, Thomas G
2015-10-01
Fungal mesh infections are a rare complication of hernia repairs with mesh. The first case of Coccidioides spp. mesh infection is described, and a systematic literature review of all known fungal mesh infections was performed. Nine cases of fungal mesh infection are reviewed. Female and male patients are equally represented, median age is 49.5 years, and critical illness and preinfection antibiotic use were common. Fungal mesh infections are rare, but potentially fatal, complications of hernias repaired with mesh. © 2015 Blackwell Verlag GmbH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Hojun; Abdeljawad, Fadi; Owen, Steven J.
Here, the mechanical properties of materials systems are highly influenced by various features at the microstructural level. The ability to capture these heterogeneities and incorporate them into continuum-scale frameworks of the deformation behavior is considered a key step in the development of complex non-local models of failure. In this study, we present a modeling framework that incorporates physically-based realizations of polycrystalline aggregates from a phase field (PF) model into a crystal plasticity finite element (CP-FE) framework. Simulated annealing via the PF model yields ensembles of materials microstructures with various grain sizes and shapes. With the aid of a novel FEmore » meshing technique, FE discretizations of these microstructures are generated, where several key features, such as conformity to interfaces, and triple junction angles, are preserved. The discretizations are then used in the CP-FE framework to simulate the mechanical response of polycrystalline α-iron. It is shown that the conformal discretization across interfaces reduces artificial stress localization commonly observed in non-conformal FE discretizations. The work presented herein is a first step towards incorporating physically-based microstructures in lieu of the overly simplified representations that are commonly used. In broader terms, the proposed framework provides future avenues to explore bridging models of materials processes, e.g. additive manufacturing and microstructure evolution of multi-phase multi-component systems, into continuum-scale frameworks of the mechanical properties.« less
Lim, Hojun; Abdeljawad, Fadi; Owen, Steven J.; ...
2016-04-25
Here, the mechanical properties of materials systems are highly influenced by various features at the microstructural level. The ability to capture these heterogeneities and incorporate them into continuum-scale frameworks of the deformation behavior is considered a key step in the development of complex non-local models of failure. In this study, we present a modeling framework that incorporates physically-based realizations of polycrystalline aggregates from a phase field (PF) model into a crystal plasticity finite element (CP-FE) framework. Simulated annealing via the PF model yields ensembles of materials microstructures with various grain sizes and shapes. With the aid of a novel FEmore » meshing technique, FE discretizations of these microstructures are generated, where several key features, such as conformity to interfaces, and triple junction angles, are preserved. The discretizations are then used in the CP-FE framework to simulate the mechanical response of polycrystalline α-iron. It is shown that the conformal discretization across interfaces reduces artificial stress localization commonly observed in non-conformal FE discretizations. The work presented herein is a first step towards incorporating physically-based microstructures in lieu of the overly simplified representations that are commonly used. In broader terms, the proposed framework provides future avenues to explore bridging models of materials processes, e.g. additive manufacturing and microstructure evolution of multi-phase multi-component systems, into continuum-scale frameworks of the mechanical properties.« less
Wellwood, James; Sculpher, Mark J; Stoker, David; Nicholls, Graham J; Geddes, Cathy; Whitehead, Anne; Singh, Rameet; Spiegelhalter, David
1998-01-01
Objective: To compare tension-free open mesh hernioplasty under local anaesthetic with transabdominal preperitoneal laparoscopic hernia repair under general anaesthetic. Design: A randomised controlled trial of 403 patients with inguinal hernias. Setting: Two acute general hospitals in London between May 1995 and December 1996. Subjects: 400 patients with a diagnosis of groin hernia, 200 in each group. Main outcome measures: Time until discharge, postoperative pain, and complications; patients’ perceived health (SF-36), duration of convalescence, and patients’ satisfaction with surgery; and health service costs. Results: More patients in the open group (96%) than in the laparoscopic group (89%) were discharged on the same day as the operation (χ2=6.7; 1 df; P=0.01). Although pain scores were lower in the open group while the effect of the local anaesthetic persisted (proportional odds ratio at 2 hours 3.5 (2.3 to 5.1)), scores after open repair were significantly higher for each day of the first week (0.5 (0.3 to 0.7) on day 7) and during the second week (0.7 (0.5 to 0.9)). At 1 month there was a greater improvement (or less deterioration) in mean SF-36 scores over baseline in the laparoscopic group compared with the open group on seven of eight dimensions, reaching significance on five. For every activity considered the median time until return to normal was significantly shorter for the laparoscopic group. Patients randomised to laparoscopic repair were more satisfied with surgery at 1 month and 3 months after surgery. The mean cost per patient of laparoscopic repair was £335 (95% confidence interval £228 to £441) more than the cost of open repair. Conclusion: This study confirms that laparoscopic hernia repair has considerable short term clinical advantages after discharge compared with open mesh hernioplasty, although it was more expensive. Key messages In the 4 hours after surgery laparoscopic hernia repair with general anaesthesia causes more pain than open repair with local anaesthesia (mainly because of the anaesthesia used) and necessitates longer stay in hospital. Laparoscopic hernia repair, however, causes less pain than open hernia repair during the first 2 weeks after discharge Laparoscopic hernia repair results in fewer episodes of wound infection, persistent local pain, genital swelling, numbness, and constipation than open repair. Urinary disturbances are more common after laparoscopic than after open repair Patients’ perception of health 1 month after the operation (assessed with the SF-36) and satisfaction with treatment is superior for laparoscopic patients who also have a shorter period of convalescence after surgery The health service cost of day case laparoscopic repair is £335 more than the cost of open mesh hernioplasty performed on a day case basis PMID:9657784
An Adaptive Mesh Algorithm: Mapping the Mesh Variables
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scannapieco, Anthony J.
2016-07-25
Both thermodynamic and kinematic variables must be mapped. The kinematic variables are defined on a separate kinematic mesh; it is the duel mesh to the thermodynamic mesh. The map of the kinematic variables is done by calculating the contributions of kinematic variables on the old thermodynamic mesh, mapping the kinematic variable contributions onto the new thermodynamic mesh and then synthesizing the mapped kinematic variables on the new kinematic mesh. In this document the map of the thermodynamic variables will be described.
Evaluation on Compressive Characteristics of Medical Stents Applied by Mesh Structures
NASA Astrophysics Data System (ADS)
Hirayama, Kazuki; He, Jianmei
2017-11-01
There are concerns about strength reduction and fatigue fracture due to stress concentration in currently used medical stents. To address these problems, meshed stents applied by mesh structures were interested for achieving long life and high strength perfromance of medical stents. The purpose of this study is to design basic mesh shapes to obatin three dimensional (3D) meshed stent models for mechanical property evaluation. The influence of introduced design variables on compressive characteristics of meshed stent models are evaluated through finite element analysis using ANSYS Workbench code. From the analytical results, the compressive stiffness are changed periodically with compressive directions, average results need to be introduced as the mean value of compressive stiffness of meshed stents. Secondly, compressive flexibility of meshed stents can be improved by increasing the angle proportional to the arm length of the mesh basic shape. By increasing the number of basic mesh shapes arranged in stent’s circumferential direction, compressive rigidity of meshed stent tends to be increased. Finaly reducing the mesh line width is found effective to improve compressive flexibility of meshed stents.
Mesh control information of windmill designed by Solidwork program
NASA Astrophysics Data System (ADS)
Mulyana, T.; Sebayang, D.; Rafsanjani, A. M. D.; Adani, J. H. D.; Muhyiddin, Y. S.
2017-12-01
This paper presents the mesh control information imposed on the windmill already designed. The accuracy of Simulation results is influenced by the quality of the created mesh. However, compared to the quality of the mesh is made, the simulation time running will be done software also increases. The smaller the size of the elements created when making the mesh, the better the mesh quality will be generated. When adjusting the mesh size, there is a slider that acts as the density regulator of the element. SolidWorks Simulation also has Mesh Control facility. Features that can adjust mesh density only in the desired part. The best results of mesh control obtained for both static and thermal simulation have ratio 1.5.
The ADER-DG method for seismic wave propagation and earthquake rupture dynamics
NASA Astrophysics Data System (ADS)
Pelties, Christian; Gabriel, Alice; Ampuero, Jean-Paul; de la Puente, Josep; Käser, Martin
2013-04-01
We will present the Arbitrary high-order DERivatives Discontinuous Galerkin (ADER-DG) method for solving the combined elastodynamic wave propagation and dynamic rupture problem. The ADER-DG method enables high-order accuracy in space and time while being implemented on unstructured tetrahedral meshes. A tetrahedral element discretization provides rapid and automatized mesh generation as well as geometrical flexibility. Features as mesh coarsening and local time stepping schemes can be applied to reduce computational efforts without introducing numerical artifacts. The method is well suited for parallelization and large scale high-performance computing since only directly neighboring elements exchange information via numerical fluxes. The concept of fluxes is a key ingredient of the numerical scheme as it governs the numerical dispersion and diffusion properties and allows to accommodate for boundary conditions, empirical friction laws of dynamic rupture processes, or the combination of different element types and non-conforming mesh transitions. After introducing fault dynamics into the ADER-DG framework, we will demonstrate its specific advantages in benchmarking test scenarios provided by the SCEC/USGS Spontaneous Rupture Code Verification Exercise. An important result of the benchmark is that the ADER-DG method avoids spurious high-frequency contributions in the slip rate spectra and therefore does not require artificial Kelvin-Voigt damping, filtering or other modifications of the produced synthetic seismograms. To demonstrate the capabilities of the proposed scheme we simulate an earthquake scenario, inspired by the 1992 Landers earthquake, that includes branching and curved fault segments. Furthermore, topography is respected in the discretized model to capture the surface waves correctly. The advanced geometrical flexibility combined with an enhanced accuracy will make the ADER-DG method a useful tool to study earthquake dynamics on complex fault systems in realistic rheologies.
Thermographic inspection of external thermal insulation systems with mechanical fixing
NASA Astrophysics Data System (ADS)
Simões, Nuno; Simões, Inês; Serra, Catarina; Tadeu, António
2015-05-01
An External Thermal Insulation Composite System (ETICS) kit may include anchors to mechanically fix the insulation product onto the wall. Using this option increases safety when compared to a simple bonded solution, however, it is more expensive and needs higher labor resources. The insulation product is then coated with rendering, which applied to the insulation material without any air gap. The rendering comprises one or more layers of coats with an embedded reinforcement. The most common multi-coat rendering system presents a base coat applied directly to the insulation product with a glass fiber mesh as reinforcement, followed by a second base coat, before a very thin coat (key coat) that prepares the surface to receive the finishing and decorative coat. The thickness of the rendering system may vary between around 5 to 10 mm. The higher thicknesses may be associated with a reinforcement composed by two layers of glass fiber mesh. The main purpose of this work is to apply infrared thermography (IRT) techniques to 2 ETICS solution (single or double layer of glass fiber mesh) and evaluate its capability in the detection of anchors. The reliability of IRT was tested using an ETICS configuration of expanded cork boards and a rendering system with one or two layers of glass fiber mesh. An active thermography approach was performed in laboratory conditions, in transmission and reflection mode. In the reflection mode halogen lamps and air heater were employed as the thermal stimulus. Air heater was also the source used in the transmission mode tests. The resulting data was processed in both time and frequency domains. In this last approach, phase contrast images were generated and studied.
2005-09-01
Computer Memory Card International Association PHY Physical PLI Position Location Information PLRS Position Location Reporting System PoP Point of...it is widely acknowledged that the JTRS program will not be providing any sustentative operational capability prior to FY’09. This reality has...Figure 5, and a man-packed antenna (AS- 3448/PSQ-4). Back-up (cryptographic key) memory is maintained by a traditional 9v 24
Changes in pelvic organ prolapse mesh mechanical properties following implantation in rats.
Ulrich, Daniela; Edwards, Sharon L; Alexander, David L J; Rosamilia, Anna; Werkmeister, Jerome A; Gargett, Caroline E; Letouzey, Vincent
2016-02-01
Pelvic organ prolapse (POP) is a multifactorial disease that manifests as the herniation of the pelvic organs into the vagina. Surgical methods for prolapse repair involve the use of a synthetic polypropylene mesh. The use of this mesh has led to significantly higher anatomical success rates compared with native tissue repairs, and therefore, despite recent warnings by the Food and Drug Administration regarding the use of vaginal mesh, the number of POP mesh surgeries has increased over the last few years. However, mesh implantation is associated with higher postsurgery complications, including pain and erosion, with higher consecutive rates of reoperation when placed vaginally. Little is known on how the mechanical properties of the implanted mesh itself change in vivo. It is assumed that the mechanical properties of these meshes remain unchanged, with any differences in mechanical properties of the formed mesh-tissue complex attributed to the attached tissue alone. It is likely that any changes in mesh mechanical properties that do occur in vivo will have an impact on the biomechanical properties of the formed mesh-tissue complex. The objective of the study was to assess changes in the multiaxial mechanical properties of synthetic clinical prolapse meshes implanted abdominally for up to 90 days, using a rat model. Another objective of the study was to assess the biomechanical properties of the formed mesh-tissue complex following implantation. Three nondegradable polypropylene clinical synthetic mesh types for prolapse repair (Gynemesh PS, Polyform Lite, and Restorelle) and a partially degradable polypropylene/polyglecaprone mesh (UltraPro) were mechanically assessed before and after implantation (n = 5/ mesh type) in Sprague Dawley rats for 30 (Gynemesh PS, Polyform Lite, and Restorelle) and 90 (UltraPro and Polyform Lite) days. Stiffness and permanent extension following cyclic loading, and breaking load, of the preimplanted mesh types, explanted mesh-tissue complexes, and explanted meshes were assessed using a multi-axial (ball-burst) method. The 4 clinical meshes varied from each other in weight, thickness, porosity, and pore size and showed significant differences in stiffness and breaking load before implantation. Following 30 days of implantation, the mechanical properties of some mesh types altered, with significant decreases in mesh stiffness and breaking load, and increased permanent extension. After 90 days these changes were more obvious, with significant decreases in stiffness and breaking load and increased permanent extension. Similar biomechanical properties of formed mesh-tissue complexes were observed for mesh types of different preimplant stiffness and structure after 90 days implantation. This is the first study to report on intrinsic changes in the mechanical properties of implanted meshes and how these changes have an impact on the estimated tissue contribution of the formed mesh-tissue complex. Decreased mesh stiffness, strength, and increased permanent extension following 90 days of implantation increase the biomechanical contribution of the attached tissue of the formed mesh-tissue complex more than previously thought. This needs to be considered when using meshes for prolapse repair. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Grundy, Brian R.
1981-01-01
The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume.
Grundy, B.R.
1981-09-29
The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume. 2 figs.
Chughtai, Bilal; Barber, Matthew D; Mao, Jialin; Forde, James C; Normand, Sharon-Lise T; Sedrakyan, Art
2017-03-01
Mesh, a synthetic graft, has been used in pelvic organ prolapse (POP) repair and stress urinary incontinence (SUI) to augment and strengthen weakened tissue. Polypropylene mesh has come under scrutiny by the US Food and Drug Administration. To examine the rates of mesh complications and invasive reintervention after the placement of vaginal mesh for POP repair or SUI surgery. This investigation was an observational cohort study at inpatient and ambulatory surgery settings in New York State. Participants were women who underwent transvaginal repair for POP or SUI with mesh between January 1, 2008, and December 31, 2012, and were followed up through December 31, 2013. They were divided into the following 4 groups based on the amount of mesh exposure: transvaginal POP repair surgery with mesh and concurrent sling use (vaginal mesh plus sling group), transvaginal POP repair with mesh and no concurrent sling use (vaginal mesh group), transvaginal POP repair without mesh but concurrent sling use for SUI (POP sling group), and sling for SUI alone (SUI sling group). The primary outcome was the occurrence of mesh complications and repeated invasive intervention within 1 year after the initial mesh implantation. A time-to-event analysis was performed to examine the occurrence of mesh erosions and subsequent reintervention. Secondary analyses of an age association (<65 vs ≥65 years) were conducted. The study identified 41 604 women who underwent 1 of the 4 procedures. The mean (SD) age of women at their initial mesh implantation was 56.2 (13.0) years. The highest risk of erosions was found in the vaginal mesh plus sling group (2.72%; 95% CI, 2.31%-3.21%) and the lowest in the SUI sling group (1.57%; 95% CI, 1.41%-1.74%). The risk of repeated surgery with concomitant erosion diagnosis was also the highest in the vaginal mesh plus sling group (2.13%; 95% CI, 1.76%-2.56%) and the lowest in the SUI sling group (1.16%; 95% CI, 1.03%-1.31%). The combined use of POP mesh and SUI mesh sling was associated with the highest erosion and repeated intervention risk, while mesh sling alone had the lowest erosion and repeated intervention risk. There is evidence for a dose-response relationship between the amount of mesh used and subsequent mesh erosions, complications, and invasive repeated intervention.
Documentation for MeshKit - Reactor Geometry (&mesh) Generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Rajeev; Mahadevan, Vijay
2015-09-30
This report gives documentation for using MeshKit’s Reactor Geometry (and mesh) Generator (RGG) GUI and also briefly documents other algorithms and tools available in MeshKit. RGG is a program designed to aid in modeling and meshing of complex/large hexagonal and rectilinear reactor cores. RGG uses Argonne’s SIGMA interfaces, Qt and VTK to produce an intuitive user interface. By integrating a 3D view of the reactor with the meshing tools and combining them into one user interface, RGG streamlines the task of preparing a simulation mesh and enables real-time feedback that reduces accidental scripting mistakes that could waste hours of meshing.more » RGG interfaces with MeshKit tools to consolidate the meshing process, meaning that going from model to mesh is as easy as a button click. This report is designed to explain RGG v 2.0 interface and provide users with the knowledge and skills to pilot RGG successfully. Brief documentation of MeshKit source code, tools and other algorithms available are also presented for developers to extend and add new algorithms to MeshKit. RGG tools work in serial and parallel and have been used to model complex reactor core models consisting of conical pins, load pads, several thousands of axially varying material properties of instrumentation pins and other interstices meshes.« less
Mellano, Erin M; Nakamura, Leah Y; Choi, Judy M; Kang, Diana C; Grisales, Tamara; Raz, Shlomo; Rodriguez, Larissa V
2016-01-01
Vaginal mesh complications necessitating excision are increasingly prevalent. We aim to study whether subclinical chronically infected mesh contributes to the development of delayed-onset mesh complications or recurrent urinary tract infections (UTIs). Women undergoing mesh removal from August 2013 through May 2014 were identified by surgical code for vaginal mesh removal. Only women undergoing removal of anti-incontinence mesh were included. Exclusion criteria included any women undergoing simultaneous prolapse mesh removal. We abstracted preoperative and postoperative information from the medical record and compared mesh culture results from patients with and without mesh extrusion, de novo recurrent UTIs, and delayed-onset pain. One hundred seven women with only anti-incontinence mesh removed were included in the analysis. Onset of complications after mesh placement was within the first 6 months in 70 (65%) of 107 and delayed (≥6 months) in 37 (35%) of 107. A positive culture from the explanted mesh was obtained from 82 (77%) of 107 patients, and 40 (37%) of 107 were positive with potential pathogens. There were no significant differences in culture results when comparing patients with delayed-onset versus immediate pain, extrusion with no extrusion, and de novo recurrent UTIs with no infections. In this large cohort of patients with mesh removed for a diverse array of complications, cultures of the explanted vaginal mesh demonstrate frequent low-density bacterial colonization. We found no differences in culture results from women with delayed-onset pain versus acute pain, vaginal mesh extrusions versus no extrusions, or recurrent UTIs using standard culture methods. Chronic prosthetic infections in other areas of medicine are associated with bacterial biofilms, which are resistant to typical culture techniques. Further studies using culture-independent methods are needed to investigate the potential role of chronic bacterial infections in delayed vaginal mesh complications.
The Risk Factors of Child Lead Poisoning in China: A Meta-Analysis
Li, You; Qin, Jian; Wei, Xiao; Li, Chunhong; Wang, Jian; Jiang, Meiyu; Liang, Xue; Xia, Tianlong; Zhang, Zhiyong
2016-01-01
Background: To investigate the risk factors of child lead poisoning in China. Methods: A document retrieval was performed using MeSH (Medical subject heading terms) and key words. The Newcastle-Ottawa Scale (NOS) was used to assess the quality of the studies, and the pooled odd ratios with a 95% confidence interval were used to identify the risk factors. We employed Review Manager 5.2 and Stata 10.0 to analyze the data. Heterogeneity was assessed by both the Chi-square and I2 tests, and publication bias was evaluated using a funnel plot and Egger’s test. Results: Thirty-four articles reporting 13,587 lead-poisoned children met the inclusion criteria. Unhealthy lifestyle and behaviors, environmental pollution around the home and potential for parents’ occupational exposure to lead were risk factors of child lead poisoning in the pooled analyses. Our assessments yielded no severe publication biases. Conclusions: Seventeen risk factors are associated with child lead poisoning, which can be used to identify high-risk children. Health education and promotion campaigns should be designed in order to minimize or prevent child lead poisoning in China. PMID:27005641
Toward An Unstructured Mesh Database
NASA Astrophysics Data System (ADS)
Rezaei Mahdiraji, Alireza; Baumann, Peter Peter
2014-05-01
Unstructured meshes are used in several application domains such as earth sciences (e.g., seismology), medicine, oceanography, cli- mate modeling, GIS as approximate representations of physical objects. Meshes subdivide a domain into smaller geometric elements (called cells) which are glued together by incidence relationships. The subdivision of a domain allows computational manipulation of complicated physical structures. For instance, seismologists model earthquakes using elastic wave propagation solvers on hexahedral meshes. The hexahedral con- tains several hundred millions of grid points and millions of hexahedral cells. Each vertex node in the hexahedrals stores a multitude of data fields. To run simulation on such meshes, one needs to iterate over all the cells, iterate over incident cells to a given cell, retrieve coordinates of cells, assign data values to cells, etc. Although meshes are used in many application domains, to the best of our knowledge there is no database vendor that support unstructured mesh features. Currently, the main tool for querying and manipulating unstructured meshes are mesh libraries, e.g., CGAL and GRAL. Mesh li- braries are dedicated libraries which includes mesh algorithms and can be run on mesh representations. The libraries do not scale with dataset size, do not have declarative query language, and need deep C++ knowledge for query implementations. Furthermore, due to high coupling between the implementations and input file structure, the implementations are less reusable and costly to maintain. A dedicated mesh database offers the following advantages: 1) declarative querying, 2) ease of maintenance, 3) hiding mesh storage structure from applications, and 4) transparent query optimization. To design a mesh database, the first challenge is to define a suitable generic data model for unstructured meshes. We proposed ImG-Complexes data model as a generic topological mesh data model which extends incidence graph model to multi-incidence relationships. We instrument ImG model with sets of optional and application-specific constraints which can be used to check validity of meshes for a specific class of object such as manifold, pseudo-manifold, and simplicial manifold. We conducted experiments to measure the performance of the graph database solution in processing mesh queries and compare it with GrAL mesh library and PostgreSQL database on synthetic and real mesh datasets. The experiments show that each system perform well on specific types of mesh queries, e.g., graph databases perform well on global path-intensive queries. In the future, we investigate database operations for the ImG model and design a mesh query language.
Gruber-Blum, S; Brand, J; Keibl, C; Redl, H; Fortelny, R H; May, C; Petter-Puchner, A H
2015-08-01
Fibrin sealant (FS) is a safe and efficient fixation method in open intraperitoneal hernia repair. While favourable results have been achieved with hydrophilic meshes, hydrophobic (such as Omega fatty acid coated) meshes (OFM) have not been specifically assessed so far. Atrium C-qur lite(®) mesh was tested in rats in models of open onlay and intraperitoneal hernia repair. 44 meshes (2 × 2 cm) were implanted in 30 male Sprague-Dawley rats in open (n = 2 meshes per animal) and intraperitoneal technique (IPOM; n = 1 mesh per animal). Animals were randomised to four groups: onlay and IPOM sutured vs. sealed. Follow-up was 6 weeks, sutured groups serving as controls. Evaluation criteria were mesh dislocation, adhesions and foreign body reaction. FS provided a reliable fixation in onlay technique, whereas OFM meshes dislocated in the IPOM position when sealed only. FS mesh fixation was safe with OFM meshes in open onlay repair. Intraperitoneal placement of hydrophobic meshes requires additional fixation and cannot be achieved with FS alone.
Courting the Buyer: The Relationship of Newspaper, Audience, and Advertisers.
ERIC Educational Resources Information Center
Thompson, Timothy N.
By applying Kenneth Burke's concepts of Order, the Secret, and the Kill to the newspaper-audience-advertiser relationship, the narrow imagery that depicts that relationship only in economic terms can be counteracted. Burke's maps of hierarchy, mystery, and transcendence in human action allow the depiction of a complex meshing of patterns,…
An inventory of publications on electronic medical records revisited.
Moorman, P W; Schuemie, M J; van der Lei, J
2009-01-01
In this short review we provide an update of our earlier inventories of publications indexed in MedLine with the MeSH term 'Medical Records Systems, Computerized'. We retrieved and analyzed all references to English articles published before January 1, 2008, and indexed in PubMed with the MeSH term 'Medical Records Systems, Computerized'. We retrieved a total of 11,924 publications, of which 3937 (33%) appeared in a journal with an impact factor. Since 2002 the number of yearly publications, and the number of journals in which those publications appeared, increased. A cluster analysis revealed three clusters: an organizational issues cluster, a technically oriented cluster and a cluster about order-entry and research. Although our previous inventory in 2003 suggested a constant yearly production of publications on electronic medical records since 1998, the current inventory shows another rise in production since 2002. In addition, many new journals and countries have shown interest during the last five years. In the last 15 years, interest in organizational issues remained fairly constant, order entry and research with systems gained attention, while interest in technical issues relatively decreased.
Taitano, William; Chacon, Luis; Simakov, Andrei Nikolaevich
2016-04-25
In this paper, we propose an adaptive velocity-space discretization scheme for the multi-species, multidimensional Rosenbluth–Fokker–Planck (RFP) equation, which is exactly mass-, momentum-, and energy-conserving. Unlike most earlier studies, our approach normalizes the velocity-space coordinate to the temporally varying individual plasma species' local thermal velocity, v th (t), and explicitly considers the resulting inertial terms in the Fokker–Planck equation. Our conservation strategy employs nonlinear constraints to enforce discretely the conservation properties of these inertial terms and the Fokker–Planck collision operator. To deal with situations of extreme thermal velocity disparities among different species, we employ an asymptotic v th -ratio-based expansion ofmore » the Rosenbluth potentials that only requires the computation of several velocity-space integrals. Numerical examples demonstrate the favorable efficiency and accuracy properties of the scheme. Specifically, we show that the combined use of the velocity-grid adaptivity and asymptotic expansions delivers many orders-of-magnitude savings in mesh resolution requirements compared to a single, static uniform mesh.« less
NASA Astrophysics Data System (ADS)
Liu, Yong; Shu, Chi-Wang; Zhang, Mengping
2018-02-01
We present a discontinuous Galerkin (DG) scheme with suitable quadrature rules [15] for ideal compressible magnetohydrodynamic (MHD) equations on structural meshes. The semi-discrete scheme is analyzed to be entropy stable by using the symmetrizable version of the equations as introduced by Godunov [32], the entropy stable DG framework with suitable quadrature rules [15], the entropy conservative flux in [14] inside each cell and the entropy dissipative approximate Godunov type numerical flux at cell interfaces to make the scheme entropy stable. The main difficulty in the generalization of the results in [15] is the appearance of the non-conservative "source terms" added in the modified MHD model introduced by Godunov [32], which do not exist in the general hyperbolic system studied in [15]. Special care must be taken to discretize these "source terms" adequately so that the resulting DG scheme satisfies entropy stability. Total variation diminishing / bounded (TVD/TVB) limiters and bound-preserving limiters are applied to control spurious oscillations. We demonstrate the accuracy and robustness of this new scheme on standard MHD examples.
NASA Astrophysics Data System (ADS)
Mössinger, Peter; Jester-Zürker, Roland; Jung, Alexander
2015-01-01
Numerical investigations of hydraulic turbo machines under steady-state conditions are state of the art in current product development processes. Nevertheless allow increasing computational resources refined discretization methods, more sophisticated turbulence models and therefore better predictions of results as well as the quantification of existing uncertainties. Single stage investigations are done using in-house tools for meshing and set-up procedure. Beside different model domains and a mesh study to reduce mesh dependencies, the variation of several eddy viscosity and Reynolds stress turbulence models are investigated. All obtained results are compared with available model test data. In addition to global values, measured magnitudes in the vaneless space, at runner blade and draft tube positions in term of pressure and velocity are considered. From there it is possible to estimate the influence and relevance of various model domains depending on different operating points and numerical variations. Good agreement can be found for pressure and velocity measurements with all model configurations and, except the BSL-RSM model, all turbulence models. At part load, deviations in hydraulic efficiency are at a large magnitude, whereas at best efficiency and high load operating point efficiencies are close to the measurement. A consideration of the runner side gap geometry as well as a refined mesh is able to improve the results either in relation to hydraulic efficiency or velocity distribution with the drawbacks of less stable numerics and increasing computational time.
40 KG Sample of Fish-Clay from Stevns Klint, Denmark
NASA Astrophysics Data System (ADS)
Gwozdz, R.; Hansen, H. J.; Rasmussen, K. L.
1992-07-01
In March 1986 a 50-m-long exposure of the cliff at Stevns Klint fell down and exposed about 40 square meters of Fish Clay. Due to this extraordinary event we were able to pick by hand about 50 kg black KT boundary layer material. After drying, the material was homogenized using a wooden pestle and an agate mortar. The powdered material was sieved through 200 mesh nylon gauze. The fraction larger than 200 mesh was collected and powdered again in an agate mortar. After four repetitions the amount of material with grain size less than 200 mesh was about 40 kg. The fraction larger than 200 mesh was reduced to about 7 kg. The 40-kg powder was mixed in a rotating polyethylene drum for three weeks. The material was analyzed by instrumental neutron activation analysis, atomic absorption and X-ray fluorescence analysis for about 40 elements. INAA was made on 20 aliquots with weight about 300 mg, 20 aliquots with weight about 80 mg, and 30 with weights between 10 and 20 mg. The preliminary results show that our KT boundary sample (1) is very homogeneous, (2) is very close in composition to other K-T boundary clays analyzed by us or described in the literature, and (3) has an Ir concentration of 32 +- 2 ng/g. We hope that our Fish Clay sample (termed by us "Mesozoic Midnight") after analysis in other laboratories and by other analytical methods may qualify as reference material in analytical work on boundary clay material.
Lu, Yao; Fu, Shaoju; Zhou, Shuanglin; Chen, Ge; Zhu, Chaoting; Li, Nannan; Ma, Ying
2018-05-01
Composite mesh with different materials composition could compensate for the drawbacks brought by single component mesh. Coating a membrane layer on the surface of macroporous mesh is a common method for preparing composite medical mesh. Electrospinning and dipping methods were introduced to form the two kinds of membrane-coated PP meshes (electro-mesh and dip-mesh); several properties were measured based on subcutaneous implantation model in rat. The results revealed that continuous tissue ingrowth could be observed for electro-mesh only with evidences of strength increase (electro-mesh: 0 week - 13.1 ± 0.88 N, 2 week - 16.87 ± 1.39 N, 4 week - 22.04 ± 2.05 N) and thickness increase (electro-mesh: 0 week - 0.437 ± 0.023 mm, 2 week - 0.488 ± 0.025 mm, 4 week - 0.576 ± 0.028 mm). However, no tissues were observed for dip-mesh in the first 2 weeks, both on macroscopic level and microscopic level, proved by strength data (dip-mesh: 0 week - 13.36 ± 1.06 N, 2 week - 13.4 ± 1.33 N, 4 week - 18.61 ± 1.89 N) and thickness data (dip-mesh: 0 week - 0.439 ± 0.018 mm, 2 week - 0.439 ± 0.019 mm, 4 week - 0.502 ± 0.032 mm). Electro-mesh had larger surface area decrease (10.74 ± 1.22%) than that of dip-mesh (2.78 ± 0.52%). The adhesion level of electro-mesh (medium adhesion) was also higher than that of dip-mesh (mild adhesion). Even if showing differences in several properties, both meshes were similar under histological observation, with the ability to support fresh tissues ingrowth. Considering operation environment, electro-mesh seems more suitable than dip-mesh with a rapid tissue growing, medium adhesion rate for repairing pelvic floor defects. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ornellas, Pâmela Oliveira; Antunes, Leonardo Dos Santos; Fontes, Karla Bianca Fernandes da Costa; Póvoa, Helvécio Cardoso Corrêa; Küchler, Erika Calvano; Iorio, Natalia Lopes Pontes; Antunes, Lívia Azeredo Alves
2016-09-01
This study aimed to perform a systematic review to assess the effectiveness of antimicrobial photodynamic therapy (aPDT) in the reduction of microorganisms in deep carious lesions. An electronic search was conducted in Pubmed, Web of Science, Scopus, Lilacs, and Cochrane Library, followed by a manual search. The MeSH terms, MeSH synonyms, related terms, and free terms were used in the search. As eligibility criteria, only clinical studies were included. Initially, 227 articles were identified in the electronic search, and 152 studies remained after analysis and exclusion of the duplicated studies; 6 remained after application of the eligibility criteria; and 3 additional studies were found in the manual search. After access to the full articles, three were excluded, leaving six for evaluation by the criteria of the Cochrane Collaboration’s tool for assessing risk of bias. Of these, five had some risk of punctuated bias. All results from the selected studies showed a significant reduction of microorganisms in deep carious lesions for both primary and permanent teeth. The meta-analysis demonstrated a significant reduction in microorganism counts in all analyses (p<0.00001). Based on these findings, there is scientific evidence emphasizing the effectiveness of aPDT in reducing microorganisms in deep carious lesions.
NASA Astrophysics Data System (ADS)
Ornellas, Pâmela Oliveira; Antunes, Leonardo Santos; Fontes, Karla Bianca Fernandes da Costa; Póvoa, Helvécio Cardoso Corrêa; Küchler, Erika Calvano; Iorio, Natalia Lopes Pontes; Antunes, Lívia Azeredo Alves
2016-09-01
This study aimed to perform a systematic review to assess the effectiveness of antimicrobial photodynamic therapy (aPDT) in the reduction of microorganisms in deep carious lesions. An electronic search was conducted in Pubmed, Web of Science, Scopus, Lilacs, and Cochrane Library, followed by a manual search. The MeSH terms, MeSH synonyms, related terms, and free terms were used in the search. As eligibility criteria, only clinical studies were included. Initially, 227 articles were identified in the electronic search, and 152 studies remained after analysis and exclusion of the duplicated studies; 6 remained after application of the eligibility criteria; and 3 additional studies were found in the manual search. After access to the full articles, three were excluded, leaving six for evaluation by the criteria of the Cochrane Collaboration's tool for assessing risk of bias. Of these, five had some risk of punctuated bias. All results from the selected studies showed a significant reduction of microorganisms in deep carious lesions for both primary and permanent teeth. The meta-analysis demonstrated a significant reduction in microorganism counts in all analyses (p<0.00001). Based on these findings, there is scientific evidence emphasizing the effectiveness of aPDT in reducing microorganisms in deep carious lesions.
ATHENA 3D: A finite element code for ultrasonic wave propagation
NASA Astrophysics Data System (ADS)
Rose, C.; Rupin, F.; Fouquet, T.; Chassignole, B.
2014-04-01
The understanding of wave propagation phenomena requires use of robust numerical models. 3D finite element (FE) models are generally prohibitively time consuming. However, advances in computing processor speed and memory allow them to be more and more competitive. In this context, EDF R&D developed the 3D version of the well-validated FE code ATHENA2D. The code is dedicated to the simulation of wave propagation in all kinds of elastic media and in particular, heterogeneous and anisotropic materials like welds. It is based on solving elastodynamic equations in the calculation zone expressed in terms of stress and particle velocities. The particularity of the code relies on the fact that the discretization of the calculation domain uses a Cartesian regular 3D mesh while the defect of complex geometry can be described using a separate (2D) mesh using the fictitious domains method. This allows combining the rapidity of regular meshes computation with the capability of modelling arbitrary shaped defects. Furthermore, the calculation domain is discretized with a quasi-explicit time evolution scheme. Thereby only local linear systems of small size have to be solved. The final step to reduce the computation time relies on the fact that ATHENA3D has been parallelized and adapted to the use of HPC resources. In this paper, the validation of the 3D FE model is discussed. A cross-validation of ATHENA 3D and CIVA is proposed for several inspection configurations. The performances in terms of calculation time are also presented in the cases of both local computer and computation cluster use.
Use of scientific social networking to improve the research strategies of PubMed readers.
Evdokimov, Pavel; Kudryavtsev, Alexey; Ilgisonis, Ekaterina; Ponomarenko, Elena; Lisitsa, Andrey
2016-02-18
Keeping up with journal articles on a daily basis is an important activity of scientists engaged in biomedical research. Usually, journal articles and papers in the field of biomedicine are accessed through the Medline/PubMed electronic library. In the process of navigating PubMed, researchers unknowingly generate user-specific reading profiles that can be shared within a social networking environment. This paper examines the structure of the social networking environment generated by PubMed users. A web browser plugin was developed to map [in Medical Subject Headings (MeSH) terms] the reading patterns of individual PubMed users. We developed a scientific social network based on the personal research profiles of readers of biomedical articles. A browser plugin is used to record the digital object identifier or PubMed ID of web pages. Recorded items are posted on the activity feed and automatically mapped to PubMed abstract. Within the activity feed a user can trace back previously browsed articles and insert comments. By calculating the frequency with which specific MeSH occur, the research interests of PubMed users can be visually represented with a tag cloud. Finally, research profiles can be searched for matches between network users. A social networking environment was created using MeSH terms to map articles accessed through the Medline/PubMed online library system. In-network social communication is supported by the recommendation of articles and by matching users with similar scientific interests. The system is available at http://bioknol.org/en/.
Dal Moro, Fabrizio; Calpista, Arturo; Mancini, Mariangela
2016-01-01
The purpose of any surgical repair of pelvic organ prolapse (POP) is to restore pelvic anatomy, preserving urinary, intestinal and sexual functions while avoiding complications. We present a novel robotic approach to hysterosacropexy (HSP) in the treatment of POP. In our technique (named 'Cupid and Psyche', recalling as it does the famous sculpture by Canova), the two branches of the MESH encircle the uterus from behind, lifting and supporting it.The aim of this technique is to resolve POP, minimizing the risk of vaginal erosion: the posterior 'embrace' of the uterus limits the direct contact of the mesh with the vagina, thus reducing any risk of erosion/extrusion at this level. We performed 10 cases of robotic HSP. All procedures are completed robotically. Median operative time (skin-to-skin) is 125 min [interquartile range (IQR) 85-145], including port placement, robot docking and console time. We have never had any cases of intraoperative or postoperative complications.With regard to short-term follow-up, analysis of outcomes is limited; in any case, we have never had any cases of MESH erosion or other complications, and no sexually active woman complained of dyspareunia. Maintaining sufficient motility of the vagina is another advantage of 'Cupid and Psyche', avoiding as it does any negative effects on patients' later sexual activity, granting more natural motility of both uterus and vagina but resolving the prolapse.Further prospective studies comparing the long-term functional outcomes of the various HSP techniques are needed to confirm these findings.
Method of and apparatus for modeling interactions
Budge, Kent G.
2004-01-13
A method and apparatus for modeling interactions can accurately model tribological and other properties and accommodate topological disruptions. Two portions of a problem space are represented, a first with a Lagrangian mesh and a second with an ALE mesh. The ALE and Lagrangian meshes are constructed so that each node on the surface of the Lagrangian mesh is in a known correspondence with adjacent nodes in the ALE mesh. The interaction can be predicted for a time interval. Material flow within the ALE mesh can accurately model complex interactions such as bifurcation. After prediction, nodes in the ALE mesh in correspondence with nodes on the surface of the Lagrangian mesh can be mapped so that they are once again adjacent to their corresponding Lagrangian mesh nodes. The ALE mesh can then be smoothed to reduce mesh distortion that might reduce the accuracy or efficiency of subsequent prediction steps. The process, from prediction through mapping and smoothing, can be repeated until a terminal condition is reached.
Zimkowski, Michael M.; Rentschler, Mark E.; Schoen, Jonathan A.; Mandava, Nageswara; Shandas, Robin
2014-01-01
Approximately 400,000 ventral hernia repair surgeries are performed each year in the United States. Many of these procedures are performed using laparoscopic minimally invasive techniques and employ the use of surgical mesh. The use of surgical mesh has been shown to reduce recurrence rates compared to standard suture repairs. The placement of surgical mesh in a ventral hernia repair procedure can be challenging, and may even complicate the procedure. Others have attempted to provide commercial solutions to the problems of mesh placement, but these have not been well accepted by the clinical community. In this article, two versions of shape memory polymer (SMP)-modified surgical mesh, and unmodified surgical mesh, were compared by performing laparoscopic manipulation in an acute porcine model. Also, SMP-integrated polyester surgical meshes were implanted in four rats for 30–33 days to evaluate chronic biocompatibility and capacity for tissue integration. Porcine results show that the modified mesh provides a controlled, temperature-activated, automated deployment when compared to an unmodified mesh. In rats, results indicate that implanted SMP-modified meshes exhibit exceptional biocompatibility and excellent integration with surrounding tissue with no noticeable differences from the unmodified counterpart. This article provides further evidence that an SMP-modified surgical mesh promises reduction in surgical placement time and that such a mesh is not substantially different from unmodified meshes in chronic biocompatibility. PMID:24327401
Highly Symmetric and Congruently Tiled Meshes for Shells and Domes
Rasheed, Muhibur; Bajaj, Chandrajit
2016-01-01
We describe the generation of all possible shell and dome shapes that can be uniquely meshed (tiled) using a single type of mesh face (tile), and following a single meshing (tiling) rule that governs the mesh (tile) arrangement with maximal vertex, edge and face symmetries. Such tiling arrangements or congruently tiled meshed shapes, are frequently found in chemical forms (fullerenes or Bucky balls, crystals, quasi-crystals, virus nano shells or capsids), and synthetic shapes (cages, sports domes, modern architectural facades). Congruently tiled meshes are both aesthetic and complete, as they support maximal mesh symmetries with minimal complexity and possess simple generation rules. Here, we generate congruent tilings and meshed shape layouts that satisfy these optimality conditions. Further, the congruent meshes are uniquely mappable to an almost regular 3D polyhedron (or its dual polyhedron) and which exhibits face-transitive (and edge-transitive) congruency with at most two types of vertices (each type transitive to the other). The family of all such congruently meshed polyhedra create a new class of meshed shapes, beyond the well-studied regular, semi-regular and quasi-regular classes, and their duals (platonic, Catalan and Johnson). While our new mesh class is infinite, we prove that there exists a unique mesh parametrization, where each member of the class can be represented by two integer lattice variables, and moreover efficiently constructable. PMID:27563368