Sample records for mesh smear sampling

  1. Direct detection of Mycobacterium tuberculosis rifampin resistance in bio-safe stained sputum smears.

    PubMed

    Lavania, Surabhi; Anthwal, Divya; Bhalla, Manpreet; Singh, Nagendra; Haldar, Sagarika; Tyagi, Jaya Sivaswami

    2017-01-01

    Direct smear microscopy of sputum forms the mainstay of TB diagnosis in resource-limited settings. Stained sputum smear slides can serve as a ready-made resource to transport sputum for molecular drug susceptibility testing. However, bio-safety is a major concern during transport of sputum/stained slides and for laboratory workers engaged in processing Mycobacterium tuberculosis infected sputum specimens. In this study, a bio-safe USP (Universal Sample Processing) concentration-based sputum processing method (Bio-safe method) was assessed on 87 M. tuberculosis culture positive sputum samples. Samples were processed for Ziehl-Neelsen (ZN) smear, liquid culture and DNA isolation. DNA isolated directly from sputum was subjected to an IS6110 PCR assay. Both sputum DNA and DNA extracted from bio-safe ZN concentrated smear slides were subjected to rpoB PCR and simultaneously assessed by DNA sequencing for determining rifampin (RIF) resistance. All sputum samples were rendered sterile by Bio-safe method. Bio-safe smears exhibited a 5% increment in positivity over direct smear with a 14% increment in smear grade status. All samples were positive for IS6110 and rpoB PCR. Thirty four percent samples were RIF resistant by rpoB PCR product sequencing. A 100% concordance (κ value = 1) was obtained between sequencing results derived from bio-safe smear slides and bio-safe sputum. This study demonstrates that Bio-safe method can address safety issues associated with sputum processing, provide an efficient alternative to sample transport in the form of bio-safe stained concentrated smear slides and can also provide information on drug (RIF) resistance by direct DNA sequencing.

  2. Direct detection of Mycobacterium tuberculosis rifampin resistance in bio-safe stained sputum smears

    PubMed Central

    Lavania, Surabhi; Anthwal, Divya; Bhalla, Manpreet; Singh, Nagendra; Haldar, Sagarika; Tyagi, Jaya Sivaswami

    2017-01-01

    Direct smear microscopy of sputum forms the mainstay of TB diagnosis in resource-limited settings. Stained sputum smear slides can serve as a ready-made resource to transport sputum for molecular drug susceptibility testing. However, bio-safety is a major concern during transport of sputum/stained slides and for laboratory workers engaged in processing Mycobacterium tuberculosis infected sputum specimens. In this study, a bio-safe USP (Universal Sample Processing) concentration-based sputum processing method (Bio-safe method) was assessed on 87 M. tuberculosis culture positive sputum samples. Samples were processed for Ziehl-Neelsen (ZN) smear, liquid culture and DNA isolation. DNA isolated directly from sputum was subjected to an IS6110 PCR assay. Both sputum DNA and DNA extracted from bio-safe ZN concentrated smear slides were subjected to rpoB PCR and simultaneously assessed by DNA sequencing for determining rifampin (RIF) resistance. All sputum samples were rendered sterile by Bio-safe method. Bio-safe smears exhibited a 5% increment in positivity over direct smear with a 14% increment in smear grade status. All samples were positive for IS6110 and rpoB PCR. Thirty four percent samples were RIF resistant by rpoB PCR product sequencing. A 100% concordance (κ value = 1) was obtained between sequencing results derived from bio-safe smear slides and bio-safe sputum. This study demonstrates that Bio-safe method can address safety issues associated with sputum processing, provide an efficient alternative to sample transport in the form of bio-safe stained concentrated smear slides and can also provide information on drug (RIF) resistance by direct DNA sequencing. PMID:29216262

  3. Evaluation of OMNIgene®•SPUTUM-stabilised sputum for long-term transport and Xpert® MTB/RIF testing in Nepal.

    PubMed

    Maharjan, B; Kelly-Cirino, C D; Weirich, A; Curry, P S; Hoffman, H; Avsar, K; Shrestha, B

    2016-12-01

    German Nepal TB Project, National Tuberculosis Reference Laboratory, Kathmandu, Nepal. To evaluate whether transporting samples in OMNIgene®•SPUTUM (OM-S) reagent from a peripheral collection site to a central laboratory in Nepal can improve tuberculosis (TB) detection and increase the sensitivity of Xpert® MTB/RIF testing. One hundred sputum samples were split manually. Each portion was assigned to the OM-S group (OM-S added at collection, airline-couriered without cold chain, no other processing required) or the standard-of-care (SOC) group (samples airline-couriered on ice, sodium hydroxide + N-acetyl-L-cysteine processing required at the laboratory). Smear microscopy and Xpert testing were performed. Transport time was 2-13 days. Overall smear results were comparable (respectively 58% and 56% smear-negative results in the OM-S and SOC groups). The rate of smear-positive, Mycobacterium tuberculosis-positive (MTB+) sample detection was identical for both treatment groups, at 95%. More smear-negative MTB+ samples were detected in the OM-S group (17% vs. 13%, P = 0.0655). Sputum samples treated with OM-S can undergo multiday ambient-temperature transport and yield comparable smear and Xpert results to those of SOC samples. Further investigation with larger sample sizes is required to assess whether treating sputum samples with OM-S could increase the sensitivity of Xpert testing in smear-negative samples.

  4. Molecular identification of leishmania species using samples obtained from negative stained smears.

    PubMed

    Mohaghegh, Ma; Fata, A; Salehi, Gh; Berenji, F; Bazzaz, M Mousavi; Rafatpanah, H; Parian, M; Movahedi, A

    2013-04-01

    Cutaneous Leishmaniasis (CL) is a parasitic skin disease. Diagnosis primarily is based on clinical signs and microscopic observation of parasite on direct stained smears or tissue sections. Sensitivity of direct smear is not as high as molecular methods. The aim of this study was to identify and characterize Leishmania species among the negative direct smears obtained from skin ulcers suspected to CL by PCR method. Among 81 patients with suspicious skin lesions to CL referred to the Parasitology lab, negative Giemsa stained smears were collected. DNA extraction performed by scraping stained smears, then PCR was performed. Among the DNA extracted from smears, L. tropica was isolated from 9 (11.1%) of the smears and L.major was not isolated from any samples. Direct microscopy on stained smears for diagnosis of leishmaniasis is not enough accurate. PCR is recommended for clinically suspected lesions with negative result of direct smear.

  5. Evaluation of genotype MTBDRplus VER 2.0 line probe assay for the detection of MDR-TB in smear positive and negative sputum samples.

    PubMed

    Meaza, Abyot; Kebede, Abebaw; Yaregal, Zelalem; Dagne, Zekarias; Moga, Shewki; Yenew, Bazezew; Diriba, Getu; Molalign, Helina; Tadesse, Mengistu; Adisse, Desalegn; Getahun, Muluwork; Desta, Kassu

    2017-04-17

    Multi drug resistant tuberculosis (MDR-TB) poses formidable challenges to TB control due to its complex diagnostic and treatment challenges and often associated with a high rate of mortality. Accurate and rapid detection of MDR-TB is critical for timely initiation of treatment. Line Probe Assay (LPA) is a qualitative in vitro diagnostic test based on DNA-STRIP technology for the identification of the M. tuberculosis complex and its resistance to rifampicin (RMP) and/or isoniazid (INH). Hain Lifescience, GmbH, Germany has improved the sensitivity of Genotype MTBDRplus VER 2.0 LPA for the detection of MDR-TB; with the possibility of applying the tool in smear negative sputum samples. A cross sectional study was conducted on 274 presumptive MDR-TB patients referred to the National TB Reference Laboratory (NTRL), Ethiopian Public Health Institute (EPHI) who submitted sputum samples for laboratory diagnosis of drug resistant-TB testing. Seventy-two smear and culture positive samples processed in smear positive direct LPA category and 197 smear negative sputum samples were processed for direct LPA. Among the smear negative samples 145 (73.6%) were culture negative and 26 (13.2%) were culture positive. All specimens were processed using NALC-NaOH method and ZN smear microscopy done from sediments. Genotype MTBDRplus VER 2.0 done from processed sputum sediments and the result was compared against the reference, BACTEC MGIT 960 culture and DST. Sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 assay was determined and P-value <0.05 was considered as statistically significant. The sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 LPA were 96.4, 100, 100 and 96.9%, respectively for the detection of MDR-TB from direct smear positive sputum samples. The sensitivity, specificity, PPV and NPV of Genotype MTBDR plus VER 2.0 LPA were 77.8, 97.2, 82.4 and 97.2%, respectively, for the detection of M. tuberculosis from direct smear negative sputum samples. Fourteen (53.8%) samples had valid results with LPA among the 26 smear negative culture positive samples. The remaining 8 (30.8%) and 4 (15.4%) were invalid and negative with LPA, respectively. The sensitivity and specificity of Genotype MTBDRplus VER 2.0 LPA were 100% for the detection of MDR-TB among 14 direct smear negative and culture positive sputum samples. The most common mutations associated with RMP and INH resistance were S531L and S315TL, respectively. A single rare mutation (C15T/A16G) was detected for INH resistance. The diagnostic performance of Genotype MTBDRplus VER 2.0 LPA in direct smear positive sputum sample was highly sensitive and specific for early detection of MDR-TB. However, the diagnostic performance of this molecular assay in direct smear negative sputum sample was low and showed a high level of invalid results for detection of M. tuberculosis and its resistance to RMP and/or INH so it is unlikely to implement Genotype MTBDRplus VER 2.0 for the detection of MDR-TB in direct smear negative sample in our routine settings. The sensitivity of the assay should be improved for detection of MDR-TB in direct smear negative sputum specimens.

  6. Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis.

    PubMed

    Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa

    2017-01-17

    Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.

  7. Direct microscopy versus sputum cytology analysis and bleach sedimentation for diagnosis of tuberculosis: a prospective diagnostic study

    PubMed Central

    2010-01-01

    Background Diagnostic options for pulmonary tuberculosis in resource-poor settings are commonly limited to smear microscopy. We investigated whether bleach concentration by sedimentation and sputum cytology analysis (SCA) increased the positivity rate of smear microscopy for smear-positive tuberculosis. Methods We did a prospective diagnostic study in a Médecins Sans Frontières-supported hospital in Mindouli, Republic of Congo. Three sputum samples were obtained from 280 consecutive pulmonary tuberculosis suspects, and were processed according to WHO guidelines for direct smear microscopy. The remainder of each sputum sample was homogenised with 2.6% bleach, sedimented overnight, smeared, and examined blinded to the direct smear result for acid-fast bacilli (AFB). All direct smears were assessed for quality by SCA. If a patient produced fewer than three good-quality sputum samples, further samples were requested. Sediment smear examination was performed independently of SCA result on the corresponding direct smear. Positivity rates were compared using McNemar's test. Results Excluding SCA, 43.2% of all patients were diagnosed as positive on direct microscopy of up to three samples. 47.9% were diagnosed on sediment microscopy, with 48.2% being diagnosed on direct microscopy, sediment microscopy, or both. The positivity rate increased from 43.2% to 47.9% with a case definition of one positive smear (≥1 AFB/100 high power fields) of three, and from 42.1% to 43.9% with two positive smears. SCA resulted in 87.9% of patients producing at least two good-quality sputum samples, with 75.7% producing three or more. Using a case definition of one positive smear, the incremental yield of bleach sedimentation was 14/121, or 11.6% (95% CI 6.5-18.6, p = 0.001) and in combination with SCA was 15/121, or 12.4% (95% CI 7.1-19.6, p = 0.002). Incremental yields with two positive smears were 5/118, or 4.2% (95% CI 1.4-9.6, p = 0.062) and 7/118, or 5.9% (95% CI 2.4-11.8, p = 0.016), respectively. Conclusions The combination of bleach sedimentation and SCA resulted in significantly increased microscopy positivity rates with a case definition of either one or two positive smears. Implementation of bleach sedimentation led to a significant increase in the diagnosis of smear-positive patients. Implementation of SCA did not result in significantly increased diagnosis of tuberculosis, but did result in improved sample quality. Requesting extra sputum samples based on SCA results, combined with bleach sedimentation, could significantly increase the detection of smear-positive patients if routinely implemented in resource-limited settings where gold standard techniques are not available. We recommend that a pilot phase is undertaken before routine implementation to determine the impact in a particular context. PMID:20858253

  8. Cervical cancer screening performed by a nurse. Evaluation in family practice.

    PubMed Central

    Thommasen, H.; Lenci, P.; Brake, I.; Anderson, G.

    1996-01-01

    OBJECTIVE: To determine whether a nurse practitioner could collect adequate Papanicolaou smear samples from the transformation zone of the cervix. DESIGN: A retrospective, descriptive study. SETTING: The Bella Coola Medical Clinic, a primary care facility located in the isolated, small village of Bella Coola, BC. PARTICIPANTS: All women who presented for Pap smears between July 1993 and June 1994. MAIN OUTCOME MEASURES: Endocervical or metaplastic cells in smear samples. RESULTS: All Pap smears performed in the Bella Coola Medical Clinic over 1 year by either the nurse or a member of the physician group (which includes family practice residents) were reviewed. Between July 1, 1993, and June 30, 1994, 149 Pap smears were done, 55 by the nurse and 94 by the physicians. All smears collected by the nurse practitioner showed endocervical or metaplastic cells. More than 90% of physician samples showed endocervical or metaplastic cells. CONCLUSIONS: A Canadian nurse practitioner can be trained to collect adequate Pap smears. PMID:8939319

  9. Plastic spatula with narrow long tip provides higher satisfactory smears for Pap test.

    PubMed

    Kaur, Pervinder; Kushtagi, Pralhad

    2013-07-01

    Ayre spatula for cervical smear collection is being used despite the suggestion that different modified spatulas provide more satisfactory sampling. To see whether the cytological pickup improves with the use of long tipped spatula. Rurally based University Hospital; crossover study. Pap smear using Ayre spatula in 500 and with plastic narrow long tip (Szalay) spatula in 500 clinic attending women was taken and analyzed. Crossover smears were taken with modified spatula in 163 and using Ayre spatula in 187 women after 2 weeks of initial smears. The same pathologist made cytological reporting for all smears and was unaware of the type of spatula used. Smears from Ayre spatula had significantly higher reports of inadequate smears (94 of 500 vs. 68 of 500 for Ayre and Szalay, respectively; P = 0.032) and it remained so even after crossover (94 of 187 vs. 70 of 163 for Ayre and Szalay, respectively; P = 0.2). Cellular quality appeared better with smears taken using Szalay spatula, but the overall abnormal smear detection rate remained similar with either collection tool (χ(2) = 1.5; P = 0.2). Proportion of satisfactory smears is higher when long tip plastic spatula is used for collection of sample.

  10. Auditing smear microscopy results according to time to detection using the BACTEC™ MGIT™ TB system.

    PubMed

    Elsaghier, A A F

    2015-09-01

    Smear microscopy is a rapid method for the identification of the most infectious patients with mycobacterial infection. Suboptimal smear microscopy may significantly compromise or delay patient isolation and contact tracing. A stringent method for auditing mycobacterial smear results is thus needed. This article proposes an auditing tool based on time to detection (TTD) of culture-positive samples using the automated BACTEC™ MGIT™ 960 TB system. In our study, sputum samples subjected to liquefaction and concentration before staining with a TTD of ≤ 13 days using the BACTEC system should be positive on smear microscopy.

  11. Human bloodstains on bone artefacts: an SEM intra- and inter-sample comparative study using ratite bird tibiotarsus.

    PubMed

    Hortolà, Policarp

    2016-11-01

    Apart from their forensic significance in crime investigation, human bloodstains have an anthropological interest due to their occurrence on certain traditional weapons and ritual objects. Previously, a guiding study of erythrocytes in experimental samples including domestic sheep (Ovis aries) tibia was carried out using a scanning electron microscope (SEM). Here, a comparative SEM study to reveal the potential differences in bloodstain surface morphology as a function of intra-sample (smear region) and inter-sample (individual smear, smearing mechanism, bone origin) parameters is reported. A fragment of emu (Dromaius novaehollandiae) tibiotarsus was smeared with an adult man's peripheral blood. After air-drying and storing indoors, the boundary and neighbouring inner areas of the three individual bloodstains obtained were examined via secondary electrons in a variable-pressure SEM working in low-vacuum mode. As a whole, desiccation microcracks were present, the limits between the smear and the substrate appeared poorly defined, and no erythrocyte negative replicas were observed in the examined areas. In addition, a putative fibrin network, more or less embedded in the dried plasma matrix, was observed in the smears' boundary. Regarding the smear region in sliding smears, the periphery and boundary revealed to be different, while the head and tail were similar. Considering individual sliding smears, they had similar characteristics. Relating to the smear region as a function of the smearing mechanism, the periphery was different whether sliding or touching, while the boundary was similar in sliding and touching smears. Concerning the smear region as a function of the bone origin, the periphery revealed to be similar in both ratite and mammalian bone, while the boundary did different in ratite and mammalian bone. The results of this study show that SEM examination can be used fruitfully to detect bloodstains on ratite bone. Combined with previous SEM results in domestic sheep bone, they suggest, further, that blood remains can be detected on objects made of bone irrespectively of the mammalian or ratite origin of this raw material. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Microstructure and mesh sensitivities of mesoscale surrogate driving force measures for transgranular fatigue cracks in polycrystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castelluccio, Gustavo M.; McDowell, David L.

    The number of cycles required to form and grow microstructurally small fatigue cracks in metals exhibits substantial variability, particularly for low applied strain amplitudes. This variability is commonly attributed to the heterogeneity of cyclic plastic deformation within the microstructure, and presents a challenge to minimum life design of fatigue resistant components. Our paper analyzes sources of variability that contribute to the driving force of transgranular fatigue cracks within nucleant grains. We also employ crystal plasticity finite element simulations that explicitly render the polycrystalline microstructure and Fatigue Indicator Parameters (FIPs) averaged over different volume sizes and shapes relative to the anticipatedmore » fatigue damage process zone. Volume averaging is necessary to both achieve description of a finite fatigue damage process zone and to regularize mesh dependence in simulations. Furthermore, results from constant amplitude remote applied straining are characterized in terms of the extreme value distributions of volume averaged FIPs. Grain averaged FIP values effectively mitigate mesh sensitivity, but they smear out variability within grains. Furthermore, volume averaging over bands that encompass critical transgranular slip planes appear to present the most attractive approach to mitigate mesh sensitivity while preserving variability within grains.« less

  13. Microstructure and mesh sensitivities of mesoscale surrogate driving force measures for transgranular fatigue cracks in polycrystals

    DOE PAGES

    Castelluccio, Gustavo M.; McDowell, David L.

    2015-05-22

    The number of cycles required to form and grow microstructurally small fatigue cracks in metals exhibits substantial variability, particularly for low applied strain amplitudes. This variability is commonly attributed to the heterogeneity of cyclic plastic deformation within the microstructure, and presents a challenge to minimum life design of fatigue resistant components. Our paper analyzes sources of variability that contribute to the driving force of transgranular fatigue cracks within nucleant grains. We also employ crystal plasticity finite element simulations that explicitly render the polycrystalline microstructure and Fatigue Indicator Parameters (FIPs) averaged over different volume sizes and shapes relative to the anticipatedmore » fatigue damage process zone. Volume averaging is necessary to both achieve description of a finite fatigue damage process zone and to regularize mesh dependence in simulations. Furthermore, results from constant amplitude remote applied straining are characterized in terms of the extreme value distributions of volume averaged FIPs. Grain averaged FIP values effectively mitigate mesh sensitivity, but they smear out variability within grains. Furthermore, volume averaging over bands that encompass critical transgranular slip planes appear to present the most attractive approach to mitigate mesh sensitivity while preserving variability within grains.« less

  14. Field Comparison of the Sampling Efficacy of Two Smear Media: Cotton Fiber and Kraft Paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hogue, M.G.

    Two materials were compared in field tests at the Defense Waste Processing Facility: kraft paper (a strong, brown paper made from wood pulp prepared with a sodium sulfate solution) and cotton fiber. Based on a sampling of forty-six pairs of smears, the cotton fiber smears provide a greater sensitivity. The cotton fiber smears collected an average of forty-four percent more beta activity than the kraft paper smears and twenty-nine percent more alpha activity. Results show a greater sensitivity with cotton fiber over kraft paper at the 95 percent confidence level. Regulatory requirements for smear materials are vague. The data demonstratemore » that the difference in sensitivity of smear materials could lead to a large difference in reported results that are subsequently used for meeting shipping regulations or evaluating workplace contamination levels.« less

  15. Audit of the practice of sputum smear examination for patients with suspected pulmonary tuberculosis in Fiji.

    PubMed

    Gounder, Shakti; Tayler-Smith, Katherine; Khogali, Mohammed; Raikabula, Maopa; Harries, Anthony D

    2013-07-01

    In Fiji, patients with suspected pulmonary tuberculosis (PTB) currently submit three sputum specimens for smear microscopy for acid-fast bacilli, but there is little information about how well this practice is carried out. A cross-sectional retrospective review was carried out in all four TB diagnostic laboratories in Fiji to determine among new patients presenting with suspected PTB in 2011: the quality of submitted sputum; the number of sputum samples submitted; the relationship between quality and number of submitted samples to smear-positivity; and positive yield from first, second and third samples. Of 1940 patients with suspected PTB, 3522 sputum samples were submitted: 997 (51.4%) patients submitted one sample, 304 (15.7%) patients submitted two samples and 639 (32.9%) submitted three samples. Sputum quality was recorded in 2528 (71.8%) of samples, of which 1046 (41.4%) were of poor quality. Poor quality sputum was more frequent in females, inpatients and children (0-14 years). Good quality sputum and a higher number of submitted samples positively correlated with smear-positivity for acid-fast bacilli. There were 122 (6.3%) patients with suspected PTB who were sputum smear positive. Of those, 89 had submitted three sputum samples: 79 (89%) were diagnosed based on the first sputum sample, 6 (7%) on the second sample and 4 (4%) on the third sample. This study shows that there are deficiencies in the practice of sputum smear examination in Fiji with respect to sputum quality and recommended number of submitted samples, although the results support the continued use of three sputum samples for TB diagnosis. Ways to improve sputum quality and adherence to recommended guidelines are needed.

  16. [Abnormalities in cervical smears stored in plastic bags: potential cause of false negatives].

    PubMed

    Ortega-González, Patricia; González-Bravo, Margarita S; Jiménez-Muñoz-Ledo, Gustavo; Macías, Alejandro E

    2011-01-01

    Cervical smear is the most economic and efficient diagnostic tool for the screening of cervical cancer. However, since plastic bags have been used in Guanajuato to transport and store smears, we have observed cytological abnormalities which difficult the diagnosis and lead to false negatives. To describe those abnormalities. Out of 340 women registered in a primary care center in Mexico, 68 were selected through systematic random sampling during 2007. A cervical smear was obtained and placed on two slides. The first sample was allowed to dry but the second one was placed into the plastic bag immediately after fixation. After 15 days all the smears were stained with the Papanicolaou technique. A certified pathologist, blinded about the variable of study, interpreted the samples according to the Bethesda system, and evaluated the presence of necrosis, edema, holes, and opportunistic microorganisms. Of the 68 smears exposed to a humid storage, 36 (53%) were inadequate for diagnosis (Fisher's exact probability < 0.001). From them, 36 (53%) had holes or lagoons, 34 (50%) had edema, 31 (46%) had necrosis, and 15 (22%) had fungus. On the other hand, the 68 dried cervical smears were all adequate for diagnosis and none had the changes or cytological abnormalities. The humid transport and storage of cervical smears produced abnormalities in the normal morphology that could lead to false negative results. The guideline for the handling of cervical smears must stress the importance of allowing the smears to dry completely after fixation and before storing them in plastic bags.

  17. Filter paper-assisted cell transfer (FaCT) technique: A novel cell-sampling technique for intraoperative diagnosis of central nervous system tumors.

    PubMed

    Kawamura, Jumpei; Kamoshida, Shingo; Shimakata, Takaaki; Hayashi, Yurie; Sakamaki, Kuniko; Denda, Tamami; Kawai, Kenji; Kuwao, Sadahito

    2017-04-01

    Intraoperative diagnosis of central nervous system (CNS) tumors provides critical guidance to surgeons in the determination of surgical resection margins and treatment. The techniques and preparations used for the intraoperative diagnosis of CNS tumors include frozen sectioning and cytologic methods (squash smear and touch imprint). Cytologic specimens, which do not have freezing artifacts, are important as an adjuvant tool to frozen sections. However, if the amount of submitted tissue samples is limited, then it is difficult to prepare both frozen sections and squash smears or touch imprint specimens from a single sample at the same time. Therefore, the objective of this study was to derive cells directly from filter paper on which tumor samples are placed. The authors established the filter paper-assisted cell transfer (FaCT) smear technique, in which tumor cells are transferred onto a glass slide directly from the filter paper sample spot after the biopsy is removed. Cell yields and diagnostic accuracy of the FaCT smears were assessed in 40 CNS tumors. FaCT smears had ample cell numbers and well preserved cell morphology sufficient for cytologic diagnosis, even if the submitted tissues were minimal. The overall diagnostic concordance rates between frozen sections and FaCT smears were 90% and 87.5%, respectively (no significant differences). When combining FaCT smears with frozen sections, the diagnostic concordance rate rose to 92.5%. The current results suggest that the FaCT smear technique is a simple and effective processing method that has significant value for intraoperative diagnosis of CNS tumors. Cancer Cytopathol 2017;125:277-282. © 2016 American Cancer Society. © 2017 American Cancer Society.

  18. Defined PEG smears as an alternative approach to enhance the search for crystallization conditions and crystal-quality improvement in reduced screens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chaikuad, Apirat, E-mail: apirat.chaikuad@sgc.ox.ac.uk; Knapp, Stefan; Johann Wolfgang Goethe-University, Building N240 Room 3.03, Max-von-Laue-Strasse 9, 60438 Frankfurt am Main

    An alternative strategy for PEG sampling is suggested through the use of four newly defined PEG smears to enhance chemical space in reduced screens with a benefit towards protein crystallization. The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially availablemore » crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant.« less

  19. Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia.

    PubMed

    Somily, Ali M; Barry, Mazin A; Habib, Hanan A; Alotaibi, Fawzia E; Al-Zamil, Fahad A; Khan, Mohammed A; Sarwar, Mohammed S; Bakhash, Nawab D; Alrabiaah, Abdulkarim A; Shakoor, Zahid A; Senok, Abiola C

    2016-12-01

    To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods: This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results: Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity  and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion: The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens.

  20. Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia

    PubMed Central

    Somily, Ali M.; Barry, Mazin A.; Habib, Hanan A.; Alotaibi, Fawzia E.; Al-Zamil, Fahad A.; Khan, Mohammed A.; Sarwar, Mohammed S.; Bakhash, Nawab D.; Alrabiaah, Abdulkarim A.; Shakoor, Zahid A.; Senok, Abiola C.

    2016-01-01

    Objectives To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens. PMID:27874159

  1. A comparative evaluation of smear layer removal by using edta, etidronic acid, and maleic acid as root canal irrigants: An in vitro scanning electron microscopic study

    PubMed Central

    Kuruvilla, Aby; Jaganath, Bharath Makonahalli; Krishnegowda, Sahadev Chickmagaravalli; Ramachandra, Praveen Kumar Makonahalli; Johns, Dexton Antony; Abraham, Aby

    2015-01-01

    Aim: The purpose of this study is to evaluate and compare the efficacy of 17% EDTA, 18% etidronic acid, and 7% maleic acid in smear layer removal using scanning electron microscopic image analysis. Materials and Methods: Thirty, freshly extracted mandibular premolars were used. The teeth were decoronated to obtain working length of 17mm and instrumentation up to 40 size (K file) with 2.5% NaOCl irrigation between each file. The samples were divided into Groups I (17% ethylenediaminetetraacetic acid (EDTA)), II (18% etidronic acid), and III (7% maleic acid) containing 10 samples each. Longitudinal sectioning of the samples was done. Then the samples were observed under scanning electron microscope (SEM) at apical, middle, and coronal levels. The images were scored according to the criteria: 1. No smear layer, 2. moderate smear layer, and 3 heavy smear layer. Statistical Analysis: Data was analyzed statistically using Kruskal–Wallis analysis of variance (ANOVA) followed by Mann-Whitney U test for individual comparisons. The level for significance was set at 0.05. Results: The present study showed that all the three experimental irrigants removed the smear layer from different tooth levels (coronal, middle, and apical). Final irrigation with 7% maleic acid is more efficient than 17% EDTA and 18% etidronic acid in the removal of smear layer from the apical third of root canal. PMID:26069414

  2. Symptomatic candidiasis: Using self sampled vaginal smears to establish the presence of Candida, lactobacilli, and Gardnerella vaginalis.

    PubMed

    Engberts, M K; Boon, M E; van Haaften, M; Heintz, A P M

    2007-10-01

    In a prospective cohort study, 10 symptomatic women with recurrent vulvovaginal candidiasis were taught how to prepare vaginal smears of their own vaginal fluids on days 7, 14, 21, and 28. The 40 smears were stained with the PAS-method and examined by three different cytopathologists for presence of Candida. Thereafter, the smears were restained with Giemsa-stain to determine presence of lactobacilli, Gardnerella vaginalis ("clue cells") and neutrophils. All three cytopathologists unequivocally established Candida blastospores and (pseudo)hyphae in 27 out of the 40 PAS-stained vaginal smears, whereas in the remaining 13 smears Candida was not found. All 10 patients had Candida in their smears during the second half of their menstrual cycle.Self sampled smears prove to be reliable for establishing the presence of Candida in symptomatic patients with candidiasis. Candida is associated with a lactobacillus-predominated vaginal flora, but with the absence of Gardnerella vaginalis. Further studies may be directed towards the interaction between the various members of the vaginal flora. This study should open molecular methodology for determining the possible interactions of lactobacilli and Candida. (c) 2007 Wiley-Liss, Inc.

  3. An audit of a cervical smear screening programme.

    PubMed

    Moodie, P J; Kljakovic, M; McLeod, D K

    1989-07-26

    An audit of a computer based screening and recall programme in a Wellington group general practice is reported (practice population 13,866). The records of all women aged between 20 and 59 years (4133 women) were checked to determine if they had had a cervical smear test in the previous two years. A random sample of women who had a cervical smear result recorded in the notes (107 women called "responders") showed that 71% gave "familiarity with the family doctor" and "acting in response to a recall letter" as reasons for choosing the place of their last smear. Satisfaction with the service was indicated by 95% of these women stating they would have their next smear at the medical centre. In the audit of all the records, a group of 667 women who had been sent a letter inviting them to have a smear done and who had apparently declined the procedure was identified (called "nonresponders"). A random sample of this group (168 women) was taken and an attempt made to interview them. In fact only 38 women could be identified as requiring a smear and even if those who refused to be interviewed (13) and those unable to be contacted (23) are added, then less than half of this sample were "true nonresponders". This suggests that the percentage of women in the practice who have been offered a smear and have refused to have one is less than 8%.

  4. Comparison of PCR, culturing and Pap smear microscopy for accurate diagnosis of genital Actinomyces.

    PubMed

    Kaya, Dilek; Demirezen, Şayeste; Hasçelik, Gülşen; Gülmez Kivanç, Dolunay; Beksaç, Mehmet Sinan

    2013-05-01

    Members of the genus Actinomyces, Gram-positive, non-spore-forming anaerobic bacteria, are normal inhabitants of the mucosal surfaces of the oral, gastrointestinal and genital tracts. Identification of these bacteria using conventional methods is generally difficult because of their complex transport and growth requirements and their fastidious and slow-growing nature. However, in recent years, the advancement of molecular techniques has provided much improved identification and differentiation of closely related Actinomyces species. The aim of the present study was to evaluate the efficacy of the PCR technique in the diagnosis of genital Actinomyces in comparison with culturing and Papanicolaou (Pap) smear microscopy. Multiple sampling was conducted from 200 women using smear microscopy, culturing and PCR. Cyto-brushes were smeared on glass slides and stained using the routine Pap technique. Culturing was performed from a sterile swab, and Actinomyces were determined using the BBL Crystal ANR ID kit. PCR was performed from a second swab, and the Actinomyces type was determined using type-specific primers designed in our laboratory. Only one vaginal fluid sample (0.5%) revealed Actinomyces-like organisms on Pap smear examination. Actinomyces were detected in nine samples (4.5%) using the BBL Crystal ANR ID kit. Using PCR, eight samples (4%) were found positive for Actinomyces. No specimens that gave positive results by Pap smear microscopy and culturing could be confirmed by PCR. Pap smear microscopy and culturing were both found to have zero sensitivity for Actinomyces. PCR appears to be a sensitive and reliable diagnostic method for the detection of Actinomyces, which are difficult to cultivate from genital samples. PCR can be used for diagnostic confirmation in cases diagnosed by conventional methods, to prevent false-positive results.

  5. Radiological Survey of Seneca Army Depot

    DTIC Science & Technology

    1986-01-01

    NUCON Smears 6. 1 ea Eberline AC-4 with planchettes and tweezers 7. 1 ea Eberline BC-4 with planchettes and tweezers 8. 1 foot locker with 4 air sampling...each detected isotope. c. sample Preparation. The smears were transferred to planchettes for counting. Approximately 500 grams of soil from each sample

  6. Xpert MTB/RIF assay can be used on archived gastric aspirate and induced sputum samples for sensitive diagnosis of paediatric tuberculosis.

    PubMed

    Singh, Sarman; Singh, Amit; Prajapati, Suneel; Kabra, Sushil K; Lodha, Rakesh; Mukherjee, Aparna; Singh, Varinder; Hesseling, Anneke C; Grewal, Harleen M S

    2015-09-29

    Tuberculosis (TB) in children is neglected, mainly due to lack of sensitive diagnostic tools. Recently Xpert MTB/RIF assay has revolutionized the diagnostic field, but its usefulness in pediatric TB has not been reported from India and no report is available on its use on long term archived samples. We recruited 130 pediatric patients with probable intrathoracic tuberculosis and their gastric aspirate (GA) and induced sputum (IS) samples on 2 consecutive days were collected between January 2009 and December 2012. All samples (n = 520) were subjected to smear examination, BACTEC-MGIT culture and in-house multiplex PCR. An aliquot of each sample was stored at -80 °C and tested in Xpert MTB/RIF assay in 2013. Sample wise and patient wise detection rate of smear microscopy was 4.4 % and 10 %, while for BACTEC-MGIT culture this rate was 24.4 % and 46.9 %, respectively. Of the 130 day 1 GA samples, 31.5 % and 27.7 % day 2 GA samples were culture positive. Only 17.7 % GA samples were positive on both days. Of the 130 IS samples collected on day 1 and day 2, 15.4 % and 23.1 % samples were culture positive. A combination of GA and IS yielded best results. Combining both GA and IS, the overall sensitivity of Xpert MTB/RIF on smear and culture positive samples was 95.6 %. In smear negative and culture positive samples its sensitivity was 62.5 %. The duration of sample storage impacted the Xpert MTB/RIF test performance (p = 0.0001). In smear positive samples stored for 650-849 days, its sensitivity was 85.7 % and 77.1 % for IS and GA samples which dropped to 33.3 % and 50 %, respectively, if stored for more than 1050 days. Confirmatory diagnosis of tuberculosis particularly in children is a medical challenge. No laboratory or radiological test can reach to a satisfactory level of diagnostic sensitivity. However, in this study we found that combination of multiple samples and multiple diagnostic tests can give much better yield, though not optimum. In present study, combination of 2 gastric aspirates (GA) and 2 induced sputum (IS) samples collected on two consecutive days, and tested on three diagnostic methods yielded a significantly high detection rate. Despite long term storage, the overall sensitivity of Xpert MTB/RIF on smear and -culture positive samples remained very high. But after storing these samples under subfreezing conditions the sensitivity of Xpert MTB/RIF decreased significantly. This is expected because even if the sample is smear and culture positive, the count of surviving mycobacteria goes down, after several years this count can reach to a undetectable level. This report shows that smear and culture positive samples stored at subfreezing conditions for several years can be used in the Xpert MTB/RIF assay, while maintaining appreciable diagnostic test sensitivity and specificity.

  7. Comparison of specimen adequacy and smear quality in oral smears prepared by manual liquid-based cytology and conventional methods

    PubMed Central

    Shukla, Surabhi; Einstein, A; Shukla, Abhilasha; Mishra, Deepika

    2015-01-01

    Background: Liquid-based cytology (LBC), recommended in the mass screening of potentially malignant cervical and oral lesions, suffers from high cost owing to the use of expensive automated devices and materials. Considering the need for cost-effective LBC techniques, we evaluated the efficacy of an inexpensive manual LBC (MLBC) technique against conventional cytological technique in terms of specimen adequacy and smear quality of oral smears. Materials and Methods: Cytological samples were collected from 21 patients using a cytobrush device. After preparation of a conventional smear, the brush containing the remaining sample was immersed in the preservative vial. The preserved material was processed by an MLBC technique and subsequently, direct smears were made from the prepared cell button. Both conventional and MLBC smears were stained by routine Papanicolaou technique and evaluated by an independent observer for the thickness of the smear, cellular distribution, resolution/clarity of cells, cellular staining characteristics and the presence of unsatisfactory background/artifacts. Each parameter was graded as satisfactory; or satisfactory, but limited; or unsatisfactory. Chi-square test was used to compare the values obtained (significance set at P ≤ 0.05). Results: MLBC technique produced a significant number of satisfactory smears with regard to cell distribution, clarity/resolution, staining characteristics and background/artifacts compared to conventional methods. Conclusions: MLBC is a cost-effective cytological technique that may produce oral smears with excellent cytomorphology and longer storage life. PMID:26980958

  8. SIMPLE MEASURES ARE AS EFFECTIVE AS INVASIVE TECHNIQUES IN THE DIAGNOSIS OF PULMONARY TUBERCULOSIS IN MALAWI

    PubMed Central

    Bell, David J; Dacombe, Russell; Graham, Stephen M; Hicks, Alexander; Cohen, Danielle; Chikaonda, Tarsizio; French, Neil; Molyneux, Malcolm E; Zijlstra, Ed E; Squire, S Bertel; Gordon, Stephen B

    2010-01-01

    Setting Detection of smear-positive pulmonary tuberculosis (PTB) cases is vital for tuberculosis control. Methods to augment sputum collection are available but their additional benefit is uncertain in resource-limited settings. Objective To compare the diagnostic yields using five methods to obtain sputum from adults diagnosed with smear-negative PTB in Malawi. Design Self-expectorated sputum was collected under supervision for microscopy and mycobacterial culture in the study laboratory. Confirmed smear-negative patients, provided physiotherapy-assisted sputum and induced sputum followed, the next morning, by gastric washing and bronchoalveolar-lavage samples. Results 150 patients, diagnosed with smear-negative PTB by the hospital service, were screened. 39 (26%) were smear-positive from supervised self-expectorated sputum examined in the study laboratory. The remaining 111 confirmed smear-negative patients were enrolled; 89% were HIV positive. Seven additional smear-positive cases were diagnosed using the augmented sputum collection techniques. No differences were observed in the numbers of cases detected using the different methods. 44 (95.6%) of the 46 smear-positive cases could be detected from self-expectorated and physiotherapy-assisted samples Conclusions For countries like Malawi, the best use of limited resources to detect smear-positive PTB cases would be to improve the quality of self-expectorated sputum collection and microscopy. The additional diagnostic yield using bronchoalveolar-lavage after induced sputum is limited. PMID:19105886

  9. Defined PEG smears as an alternative approach to enhance the search for crystallization conditions and crystal-quality improvement in reduced screens

    PubMed Central

    Chaikuad, Apirat; Knapp, Stefan; von Delft, Frank

    2015-01-01

    The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially available crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant. PMID:26249344

  10. Defined PEG smears as an alternative approach to enhance the search for crystallization conditions and crystal-quality improvement in reduced screens.

    PubMed

    Chaikuad, Apirat; Knapp, Stefan; von Delft, Frank

    2015-08-01

    The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially available crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant.

  11. A Floating Node Method for the Modelling of Discontinuities Within a Finite Element

    NASA Technical Reports Server (NTRS)

    Pinho, Silvestre T.; Chen, B. Y.; DeCarvalho, Nelson V.; Baiz, P. M.; Tay, T. E.

    2013-01-01

    This paper focuses on the accurate numerical representation of complex networks of evolving discontinuities in solids, with particular emphasis on cracks. The limitation of the standard finite element method (FEM) in approximating discontinuous solutions has motivated the development of re-meshing, smeared crack models, the eXtended Finite Element Method (XFEM) and the Phantom Node Method (PNM). We propose a new method which has some similarities to the PNM, but crucially: (i) does not introduce an error on the crack geometry when mapping to natural coordinates; (ii) does not require numerical integration over only part of a domain; (iii) can incorporate weak discontinuities and cohesive cracks more readily; (iv) is ideally suited for the representation of multiple and complex networks of (weak, strong and cohesive) discontinuities; (v) leads to the same solution as a finite element mesh where the discontinuity is represented explicitly; and (vi) is conceptually simpler than the PNM.

  12. Computer-aided diagnosis software for vulvovaginal candidiasis detection from Pap smear images.

    PubMed

    Momenzadeh, Mohammadreza; Vard, Alireza; Talebi, Ardeshir; Mehri Dehnavi, Alireza; Rabbani, Hossein

    2018-01-01

    Vulvovaginal candidiasis (VVC) is a common gynecologic infection and it occurs when there is overgrowth of the yeast called Candida. VVC diagnosis is usually done by observing a Pap smear sample under a microscope and searching for the conidium and mycelium components of Candida. This manual method is time consuming, subjective and tedious. Any diagnosis tools that detect VVC, semi- or full-automatically, can be very helpful to pathologists. This article presents a computer aided diagnosis (CAD) software to improve human diagnosis of VVC from Pap smear samples. The proposed software is designed based on phenotypic and morphology features of the Candida in Pap smear sample images. This software provide a user-friendly interface which consists of a set of image processing tools and analytical results that helps to detect Candida and determine severity of illness. The software was evaluated on 200 Pap smear sample images and obtained specificity of 91.04% and sensitivity of 92.48% to detect VVC. As a result, the use of the proposed software reduces diagnostic time and can be employed as a second objective opinion for pathologists. © 2017 Wiley Periodicals, Inc.

  13. Lot quality assurance sampling of sputum acid-fast bacillus smears for assessing sputum smear microscopy centers.

    PubMed

    Selvakumar, N; Murthy, B N; Prabhakaran, E; Sivagamasundari, S; Vasanthan, Samuel; Perumal, M; Govindaraju, R; Chauhan, L S; Wares, Fraser; Santha, T; Narayanan, P R

    2005-02-01

    Assessment of 12 microscopy centers in a tuberculosis unit by blinded checking of eight sputum smears selected by using a lot quality assurance sampling (LQAS) method and by unblinded checking of all positive and five negative slides, among the slides examined in a month in a microscopy centre, revealed that the LQAS method can be implemented in the field to monitor the performance of acid-fast bacillus microscopy centers in national tuberculosis control programs.

  14. Lot Quality Assurance Sampling of Sputum Acid-Fast Bacillus Smears for Assessing Sputum Smear Microscopy Centers

    PubMed Central

    Selvakumar, N.; Murthy, B. N.; Prabhakaran, E.; Sivagamasundari, S.; Vasanthan, Samuel; Perumal, M.; Govindaraju, R.; Chauhan, L. S.; Wares, Fraser; Santha, T.; Narayanan, P. R.

    2005-01-01

    Assessment of 12 microscopy centers in a tuberculosis unit by blinded checking of eight sputum smears selected by using a lot quality assurance sampling (LQAS) method and by unblinded checking of all positive and five negative slides, among the slides examined in a month in a microscopy centre, revealed that the LQAS method can be implemented in the field to monitor the performance of acid-fast bacillus microscopy centers in national tuberculosis control programs. PMID:15695704

  15. Detection and Genotyping of Human Papillomavirus in Self-Obtained Cervicovaginal Samples by Using the FTA Cartridge: New Possibilities for Cervical Cancer Screening ▿

    PubMed Central

    Lenselink, Charlotte H.; de Bie, Roosmarie P.; van Hamont, Dennis; Bakkers, Judith M. J. E.; Quint, Wim G. V.; Massuger, Leon F. A. G.; Bekkers, Ruud L. M.; Melchers, Willem J. G.

    2009-01-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF10-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening. PMID:19553570

  16. Detection and genotyping of human papillomavirus in self-obtained cervicovaginal samples by using the FTA cartridge: new possibilities for cervical cancer screening.

    PubMed

    Lenselink, Charlotte H; de Bie, Roosmarie P; van Hamont, Dennis; Bakkers, Judith M J E; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G

    2009-08-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF(10)-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening.

  17. Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study.

    PubMed

    Pham, Thu Hang; Peter, Jonathan; Mello, Fernanda C Q; Parraga, Tommy; Lan, Nguyen Thi Ngoc; Nabeta, Pamela; Valli, Eloise; Caceres, Tatiana; Dheda, Keertan; Dorman, Susan E; Hillemann, Doris; Gray, Christen M; Perkins, Mark D

    2018-03-01

    To evaluate the diagnostic performance of TB-LAMP, a manual molecular tuberculosis (TB) detection method, and provide comparison to the Xpert MTB/RIF assay. In a large multicentre study, two sputum samples were collected from participants with TB symptoms in reference laboratories in Peru, South Africa, Brazil, and Vietnam. Each sample was tested with TB-LAMP. The reference standard consisted of four direct smears, four cultures, and clinical and radiological findings. Individuals negative on conventional tests were followed up after 8 weeks. The Xpert MTB/RIF assay was performed on fresh or frozen samples as a molecular test comparison. A total of 1036 adults with suspected TB were enrolled. Among 375 culture-confirmed TB cases with 750 sputum samples, TB-LAMP detected 75.6% (95% confidence interval (CI) 71.8-79.4%), including 97.9% (95% CI 96.4-99.4%) of smear-positive TB samples and 46.6% (95% CI 40.6-52.7%) of smear-negative TB samples. Specificity in 477 culture-negative participants not treated for TB (954 sputum samples) was 98.7% (95% CI 97.9-99.6%). TB-LAMP test results were indeterminate in 0.3% of cases. TB-LAMP detects nearly all smear-positive and half of smear-negative TB cases and has a high specificity when performed in reference laboratories. Performance was similar to the Xpert MTB/RIF assay. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  18. The External Quality Assessment Scheme (EQAS): Experiences of a medium sized accredited laboratory.

    PubMed

    Bhat, Vivek; Chavan, Preeti; Naresh, Chital; Poladia, Pratik

    2015-06-15

    We put forth our experiences of EQAS, analyzed the result discrepancies, reviewed the corrective actions and also put forth strategies for risk identification and prevention of potential errors in a medical laboratory. For hematology, EQAS samples - blood, peripheral and reticulocyte smears - were received quarterly every year. All the blood samples were processed on HMX hematology analyzer by Beckman-Coulter. For clinical chemistry, lyophilized samples were received and were processed on Siemens Dimension Xpand and RXL analyzers. For microbiology, EQAS samples were received quarterly every year as lyophilized strains along with smears and serological samples. In hematology no outliers were noted for reticulocyte and peripheral smear examination. Only one outlier was noted for CBC. In clinical chemistry outliers (SDI ≥ 2) were noted in 7 samples (23 parameters) out of total 36 samples (756 parameters) processed. Thirteen of these parameters were analyzed as random errors, 3 as transcriptional errors and seven instances of systemic error were noted. In microbiology, one discrepancy was noted in isolate identification and in the grading of smears for AFB by Ziehl Neelsen stain. EQAS along with IQC is a very important tool for maintaining optimal quality of services. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. The effect of root surface conditioning on smear layer removal in periodontal regeneration (a scanning electron microscopic study)

    NASA Astrophysics Data System (ADS)

    Fidyawati, D.; Soeroso, Y.; Masulili, S. L. C.

    2017-08-01

    The role of root surface conditioning treatment on smear layer removal of human teeth is affected by periodontitis in periodontal regeneration. The objective of this study is to analyze the smear layer on root surface conditioned with 2.1% minocycline HCl ointment (Periocline), and 24% EDTA gel (Prefgel). A total of 10 human teeth indicated for extraction due to chronic periodontitis were collected and root planed. The teeth were sectioned in thirds of the cervical area, providing 30 samples that were divided into three groups - minocycline ointment treatment, 24% EDTA gel treatment, and saline as a control. The samples were examined by scanning electron microscope. No significant differences in levels of smear layer were observed between the minocycline group and the EDTA group (p=0.759). However, there were significant differences in the level of smear layer after root surface treatment in the minocycline and EDTA groups, compared with the control group (p=0.00). There was a relationship between root surface conditioning treatment and smear layer levels following root planing.

  20. A comparative study of blood smear, QBC and antigen detection for diagnosis of malaria.

    PubMed

    Parija, S C; Dhodapkar, Rahul; Elangovan, Subashini; Chaya, D R

    2009-01-01

    Rapid diagnosis is prerequisite for effective treatment and reducing mortality and morbidity of malaria. This study was taken up to compare the efficacy of various methods available, i.e., thick and thin smear, quantitative buffy coat (QBC), plasmodium lactate dehydrogenase and aldolase in blood of patient. A total of 411 samples were collected from patients presenting with classic symptoms of malaria. For traditional microscopy; thick and thin smears were prepared and stained with Leishman's stain, taking thick smear as gold standard, thin smear had a sensitivity and specificity of 54.8% and 100%, respectively. QBC and antigen detection was done using commercially available kits; out of 411 samples, QBC and Malariagen were positive in 66 and 62 cases, with a sensitivity of 78% and 75%, respectively. Leishman's thick smear, although cost effective, is difficult to interpret for inexperienced microscopists; so if facilities are available, QBC should be used for routine diagnosis. In places where facilities are not available, rapid, simple and easy to interpret antigen detection test can be used despite low sensitivity.

  1. Usefulness of interferon-γ release assay for the diagnosis of sputum smear-negative pulmonary and extra-pulmonary TB in Zhejiang Province, China.

    PubMed

    Ji, Lei; Lou, Yong-Liang; Wu, Zhong-Xiu; Jiang, Jin-Qin; Fan, Xing-Li; Wang, Li-Fang; Liu, Xiao-Xiang; Du, Peng; Yan, Jie; Sun, Ai-Hua

    2017-09-01

    Quick diagnosis of smear-negative pulmonary tuberculosis (TB) and extra-pulmonary TB are urgently needed in clinical diagnosis. Our research aims to investigate the usefulness of the interferon-γ release assay (IGRA) for the diagnosis of smear-negative pulmonary and extra-pulmonary TB. We performed TB antibody and TB-IGRA tests on 389 pulmonary TB patients (including 120 smear-positive pulmonary TB patients and 269 smear-negative pulmonary TB patients), 113 extra-pulmonary TB patients, 81 patients with other pulmonary diseases and 100 healthy controls. Blood samples for the TB-Ab test and the TB-IGRA were collected, processed, and interpreted according to the manufacturer's protocol. The detection ratio of smear-positive pulmonary TB patients and smear-negative pulmonary TB patients were 90.8% (109 of 120) and 89.6% (241 of 269), respectively. There was no statistically significant difference of its performance between these two sample sets (P > 0.05). The detection ratio of positive TB patients and extra-pulmonary TB patients were 90.0% (350 of 389) and 87.6% (99 of 113), respectively, which was not significantly different (P > 0.05). In this work, the total detection ratio using TB-IGRA was 89.4%, therefore TB-IGRA has diagnostic values in smear-negative pulmonary TB and extra-pulmonary TB diagnosis.

  2. Air and smear sample calculational tool for Fluor Hanford Radiological control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BAUMANN, B.L.

    2003-07-11

    A spreadsheet calculation tool was developed to automate the calculations performed for determining the concentration of airborne radioactivity and smear counting as outlined in HNF-13536, Section 5.2.7, ''Analyzing Air and Smear Samples''. This document reports on the design and testing of the calculation tool. Radiological Control Technicians (RCTs) will save time and reduce hand written and calculation errors by using an electronic form for documenting and calculating work place air samples. Current expectations are RCTs will perform an air sample and collect the filter or perform a smear for surface contamination. RCTs will then survey the filter for gross alphamore » and beta/gamma radioactivity and with the gross counts utilize either hand calculation method or a calculator to determine activity on the filter. The electronic form will allow the RCT with a few key strokes to document the individual's name, payroll, gross counts, instrument identifiers; produce an error free record. This productivity gain is realized by the enhanced ability to perform mathematical calculations electronically (reducing errors) and at the same time, documenting the air sample.« less

  3. An in vitro evaluation of passive ultrasonic agitation of different irrigants on smear layer removal after post space preparation: a scanning electron microscopic study.

    PubMed

    Srirekha, A; Rashmi, K; Hegde, Jayshree; Lekha, S; Rupali, K; Reshmi, George

    2013-09-01

    This study evaluated the removal of debris and smear layer after post space preparation using different irrigations and passive ultrasonic agitation. Sixty human premolars were decoronated and post space prepared after endodontic therapy. The samples were then randomly divided into three experimental groups (Groups A, B, C) and one control group (Group D) with fifteen samples in each group. Groups A and B samples were treated with 10 % citric acid and 17 % ethylenediamintetraacetic acid (EDTA), respectively and passive ultrasonic agitation was done, rinsed with sodium hypochlorite and finally flushed with saline. Group C samples were conditioned with 36 % phosphoric acid and then rinsed with saline. The control group was treated with 3 % sodium hypochlorite, passive ultrasonic agitation done and flushed with saline. The samples were sectioned and evaluated for debris and smear layer removal under scanning electron microscope. 10 % citric acid showed the best removal of smear layer when compared with 17 % EDTA and 36 % phosphoric acid, but was not statistically significant (p > 0.05). The difference in scoring for debris and smear layer removal in the coronal, middle and apical third of post space of experimental groups in comparison with control group was statistically significant (p < 0.001).

  4. Detection of the HTLV-I gene on cytologic smear slides.

    PubMed

    Kashima, Kenji; Nagahama, Junji; Sato, Keiji; Tanamachi, Hiroyuki; Gamachi, Ayako; Daa, Tsutomu; Nakayama, Iwao; Yokoyama, Shigeo

    2002-01-01

    To apply the polymerase chain reaction (PCR) for detection of the HTLV-I gene from cytologic smear slides. Samples were from seven cases of serum anti-ATL antibody (ATLA)-positive T-cell lymphoma and three from ATLA-negative T-cell lymphoma. Six of the seven ATLA-positive cases were confirmed to be ATLL by Southern blotting. From the seventh case a fresh sample for blotting could not obtained. DNA was extracted from the cytologic smear slides of all 10 cases; they had been stained with Papanicolaou or May-Giemsa stain, digested with proteinase K and precipitated with phenol and ethanol. The target sequence in the pX region of the HTLV-I gene was amplified by PCR. All seven ATLA-positive cases, including one that had not yet been confirmed by Southern blotting, showed a single band, as predicted, while the three ATLA-negative cases showed no band. If cytologic smear slides are available but a fresh sample is not, the PCR method should provide evidence that the virus is present since in our study sufficient DNA templates were successfully extracted from the stained cytologic smear slides for detection of the virus.

  5. Who is getting Pap smears in urban Peru?

    PubMed Central

    Paz Soldan, Valerie A; Lee, Frank H; Carcamo, Cesar; Holmes, King K; Garnett, Geoff P; Garcia, Patricia

    2008-01-01

    Background Cervical cancer, although usually preventable by Pap smear screening, remains the leading cause of cancer-related deaths among women in Peru. The percentages and characteristics of women in Peru who have or have not had a Pap smear have not been defined. Methods In an urban community randomized trial of sexually transmitted infection (STI)/HIV prevention in Peru, 6712 randomly selected women between the ages of 18 and 29 from 20 cities were interviewed regarding having had cervical Pap smears. Results Among women sampled, only 30.9% had had a Pap smear. By multivariate analysis, the main predictors of having a Pap smear were having had sex, having had children, completion of secondary education and increasing age. Regional variations were also found: women from the highlands and rainforest were less likely to have had Pap smears than women from the coast. Conclusion A norm of seeking and receiving Pap smears has not been established among sexually active young Peruvian women. To improve Pap smear coverage in Peru, promotion efforts should target underserved women and regions with less coverage. PMID:18653515

  6. [Adhesion of sealer cements to dentin with and without smear layer].

    PubMed

    Gettleman, B H; Messer, H H; ElDeeb, M E

    1991-01-01

    The influence of a smear layer on the adhesion of sealer cements to dentin was assessed in recently extracted human anterior teeth. A total of 120 samples was tested, 40 per sealer; 20 each with and without the smear layer. The teeth were split longitudinally, and the internal surfaces were ground flat. One-half of each tooth was left with the smear layer intact, while the other half had the smear removed by washing for 3 min with 17% EDTA followed by 5.25% NaOCI. Evidence of the ability to remove the smear layer was verified by scanning electron microscopy. Using a specially designed jig, the sealer was placed into a 4-mm wide x 4 mm deep well which was then set onto the tooth.

  7. Investigation of OMNIgene·SPUTUM performance in delayed tuberculosis testing by smear, culture, and Xpert MTB/RIF assays in Uganda.

    PubMed

    Kelly-Cirino, C D; Musisi, E; Byanyima, P; Kaswabuli, S; Andama, A; Sessolo, A; Sanyu, I; Zawedde, J; Curry, P S; Huang, L

    2017-06-01

    OMNIgene·SPUTUM (OM-S) is a sample transport reagent designed to work with all tuberculosis diagnostics while eliminating the need for cold chain. OM-S-treated sputum samples were assayed in several tests after multiday holds. Raw sputa from 100 patients underwent direct smear microscopy, were manually split and assigned to the OM-S group [OM-S added at collection (no other processing required) and tested after 0- to 5-day holds at room temperature] or standard-of-care (SOC) group (NaOH/N-acetyl l-cysteine decontamination, all tested on day of collection). Concentrated smear microscopy, Lowenstein Jensen (LJ) culture, and mycobacteria growth indicator tube (MGIT) culture were performed. For patients with negative direct smear, a second sample was split, with SOC (raw sputum) and OM-S portions (sediment) tested in the Xpert MTB/RIF (Xpert) assay. OM-S group and SOC group results were strongly concordant on all four tests [range, 89% (MGIT)-97% (Xpert)]. OM-S MGIT, LJ, and Xpert tests were in statistical agreement with SOC MGIT as reference. OM-S specimens had lower culture contamination rates (3% vs. 10% LJ; 2% vs. 5% MGIT) but required, on average, 5.6 additional days to become MGIT-positive. The findings suggest that samples held/transported in OM-S are compatible with smear microscopy, LJ or MGIT culture, and Xpert, and perform comparably to fresh sputum samples. Larger feasibility studies are warranted. Copyright © 2017. Published by Elsevier Ltd.

  8. A novel sputum transport solution eliminates cold chain and supports routine tuberculosis testing in Nepal.

    PubMed

    Maharjan, Bhagwan; Shrestha, Bhabana; Weirich, Alexandra; Stewart, Andrew; Kelly-Cirino, Cassandra D

    2016-12-01

    This preliminary study evaluated the transport reagent OMNIgene SPUTUM (OMS) in a real-world, resource-limited setting: a zonal hospital and national tuberculosis (TB) reference laboratory, Nepal. The objectives were to: (1) assess the performance of OMS for transporting sputum from peripheral sites without cold chain stabilization; and (2) compare with Nepal's standard of care (SOC) for Mycobacterium tuberculosis smear and culture diagnostics. Sixty sputa were manually split into a SOC sample (airline-couriered to the laboratory, conventional processing) and an OMS sample (OMS added at collection, no cold chain transport or processing). Smear microscopy and solid culture were performed. Transport was 0-8days. Forty-one samples (68%) were smear-positive using both methods. Of the OMS cultures, 37 (62%) were positive, 22 (36%) were negative, and one (2%) was contaminated. Corresponding SOC results were 32 (53%), 21 (35%), and seven (12%). OMS "rescued" six (i.e., missed using SOC) compared with one rescue using SOC. Of smear-positives, six SOC samples produced contaminated cultures whereas only one OMS sample was contaminated. OMS reduced culture contamination from 12% to 2%, and improved TB detection by 9%. The results suggest that OMS could perform well as a no cold chain, long-term transport solution for smear and culture testing. The findings provide a basis for larger feasibility studies. Copyright © 2016 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  9. Analysis of small-angle X-ray scattering data in the presence of significant instrumental smearing

    PubMed Central

    Bergenholtz, Johan; Ulama, Jeanette; Zackrisson Oskolkova, Malin

    2016-01-01

    A laboratory-scale small-angle X-ray scattering instrument with pinhole collimation has been used to assess smearing effects due to instrumental resolution. A new, numerically efficient method to smear ideal model intensities is developed and presented. It allows for directly using measured profiles of isotropic but otherwise arbitrary beams in smearing calculations. Samples of low-polydispersity polymer spheres have been used to show that scattering data can in this way be quantitatively modeled even when there is substantial distortion due to instrumental resolution. PMID:26937235

  10. Under-reporting of sputum smear-positive tuberculosis cases in Kenya.

    PubMed

    Tollefson, D; Ngari, F; Mwakala, M; Gethi, D; Kipruto, H; Cain, K; Bloss, E

    2016-10-01

    Although an estimated three million tuberculosis (TB) cases worldwide are missed by national TB programs annually, the level of under-reporting of diagnosed cases in high TB burden settings is largely unknown. To quantify and describe under-reporting of sputum smear-positive TB cases in Kenya. A national-level retrospective TB inventory study was conducted. All sputum smear-positive TB cases diagnosed by public or private laboratories during 1 April-30 June 2013 were extracted from laboratory registers in 73 randomly sampled subcounties and matched to TB cases in the national TB surveillance system (TIBU). Bivariate and multivariate analyses were conducted. In the subcounties sampled, 715 of 3409 smear-positive TB cases in laboratory registers were not found in TIBU. The estimated level of under-reporting of smear-positive TB cases in Kenya was 20.7% (95%CI 18.4-23.0). Under-reporting was greatest in subcounties with a high TB burden. Unreported cases were more likely to be patients aged ⩾55 years, have scanty smear results, and be diagnosed at large facilities, private facilities, and facilities in high TB burden regions. In Kenya, one fifth of smear-positive TB cases diagnosed during the study period went unreported, suggesting that the true TB burden is higher than reported. TB surveillance in Kenya should be strengthened to ensure all diagnosed TB cases are reported.

  11. Reduced detection by Ziehl-Neelsen method of acid-fast bacilli in sputum samples preserved in cetylpyridinium chloride solution.

    PubMed

    Selvakumar, N; Sudhamathi, S; Duraipandian, M; Frieden, T R; Narayanan, P R

    2004-02-01

    Twelve health facilities implementing the DOTS strategy, and the Tuberculosis Research Centre (TRC), Chennai, India. To determine the detection rates using Ziehl-Neelsen (ZN) and auramine-phenol to stain acid-fast bacilli (AFB) in sputum samples stored in cetylpyridinium chloride (CPC) solution. Two smears were prepared from each of 988 sputum samples collected in CPC and randomly allocated, one to ZN and the other to auramine-phenol staining. All samples were processed for culture of Mycobacterium tuberculosis. A significantly higher proportion of samples were negative using the ZN method compared to the auramine-phenol method (74.5% vs. 61.8%, McNamara's paired chi2 test; P < 0.001). Among 377 samples that were positive using auramine-phenol, 44% were negative using ZN. There were more culture-positive, smear-negative samples in ZN (52.7%) than in auramine-phenol (30%); the difference attained statistical significance (McNemar's paired chi2 test; P < 0.00004). Using ZN, of the 104 smears made immediately after collection, 52 were positive for AFB, of which only 35 (67.3%) were positive after storage in CPC; the reduction in the number of positive smears attained statistical significance (McNemar's paired chi2 test; P = 0.004). Detection of AFB in sputum samples preserved in CPC is significantly reduced using ZN staining.

  12. Veda-scope: More comfortable than the bivalve speculum and cytologically equivalent.

    PubMed

    Longmore, Peter G

    2004-04-01

    The aim of the present study was to confirm that the Veda-scope is equivalent to the bivalve speculum in the collection of endocervical cells, as confirmation of adequate cervical sampling for Pap smear testing. The study also aimed to assess the comfort level of the Veda-scope compared to the traditional bivalve speculum and the patient preference of the Veda-scope compared to the bivalve speculum. Multicentre, randomised, controlled crossover, cytologist blinded study. The total number of subjects enrolled in the study were 250. The number of evaluable subjects were 210. In primary efficacy analysis, no significant difference was seen between the presence or absence of endocervical cells in the smears using either the Veda-scope or the bivalve speculum. There was a high concordance level between the diagnosis assigned to each specimen of a paired sample, the diagnosis agreeing in 97.6% cases. The primary reason given by many women for avoidance of regular Pap smear examinations is the discomfort or pain experienced with sample collection with the bivalve speculum. In the present study, 92% of subjects indicated a preference for the Veda-scope for Pap smear collection, while only 8.4% preferred the bivalve speculum. Subject preference was also assessed with respect to how the subject rated the comfort level of her previous Pap smear. In subjects who rated their previous Pap smear as very comfortable or comfortable, 86% expressed a preference for the Veda-scope. This rose to 93% in subjects who rated their previous Pap smear as only tolerable. The results of the present study show that Pap smear collections with the Veda-scope are of equal quality to those collected with the bivalve speculum, with an equivalent diagnostic outcome. A very strong preference for the Veda-scope was shown by the women enrolled in the present study based on the comfort levels experienced with the two devices.

  13. Comparison of variants of carbol-fuchsin solution in Ziehl-Neelsen for detection of acid-fast bacilli.

    PubMed

    Selvakumar, N; Sekar, M Gomathi; Rahman, F; Syamsunder, A; Duraipandian, M; Wares, F; Narayanan, P R

    2005-02-01

    To evaluate Ziehl-Neelsen (ZN) staining using variants of carbol-fuchsin solution, duplicate smears from 416 samples were stained with ZN, one set with 1% basic fuchsin and the other 0.3%. Another set of duplicate smears from 398 samples were stained with ZN, one with 1% basic fuchsin and the other 0.1%. The coded smears were read and discrepancies resolved. All samples underwent mycobacterial culture. The sensitivity of ZN using 0.3% (65%) and 1% basic fuchsin (62%) was comparable, while it was reduced using 0.1% (74%) compared to 1% basic fuchsin (83%). Reducing the concentration of basic fuchsin below 0.3% in ZN staining was found to significantly reduce its sensitivity.

  14. Liquid-based cytology for primary cervical cancer screening: a multi-centre study

    PubMed Central

    Monsonego, J; Autillo-Touati, A; Bergeron, C; Dachez, R; Liaras, J; Saurel, J; Zerat, L; Chatelain, P; Mottot, C

    2001-01-01

    The aim of this six-centre, split-sample study was to compare ThinPrep fluid-based cytology to the conventional Papanicolaou smear. Six cytopathology laboratories and 35 gynaecologists participated. 5428 patients met the inclusion criteria (age > 18 years old, intact cervix, informed consent). Each cervical sample was used first to prepare a conventional Pap smear, then the sampling device was rinsed into a PreservCyt vial, and a ThinPrep slide was made. Screening of slide pairs was blinded (n = 5428). All non-negative concordant cases (n = 101), all non-concordant cases (n = 206), and a 5% random sample of concordant negative cases (n = 272) underwent review by one independent pathologist then by the panel of 6 investigators. Initial (blinded) screening results for ThinPrep and conventional smears were correlated. Initial diagnoses were correlated with consensus cytological diagnoses. Differences in disease detection were evaluated using McNemar's test. On initial screening, 29% more ASCUS cases and 39% more low-grade squamous intraepithelial lesions (LSIL) and more severe lesions (LSIL+) were detected on the ThinPrep slides than on the conventional smears (P = 0.001), including 50% more LSIL and 18% more high-grade SIL (HSIL). The ASCUS:SIL ratio was lower for the ThinPrep method (115:132 = 0.87:1) than for the conventional smear method (89:94 = 0.95:1). The same trend was observed for the ASCUS/AGUS:LSIL ratio. Independent and consensus review confirmed 145 LSIL+ diagnoses; of these, 18% more had been detected initially on the ThinPrep slides than on the conventional smears (P = 0.041). The ThinPrep Pap Test is more accurate than the conventional Pap test and has the potential to optimize the effectiveness of primary cervical cancer screening. © 2001 Cancer Research Campaign http://www.bjcancer.com PMID:11161401

  15. Implementation of a Smeared Crack Band Model in a Micromechanics Framework

    NASA Technical Reports Server (NTRS)

    Pineda, Evan J.; Bednarcyk, Brett A.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    The smeared crack band theory is implemented within the generalized method of cells and high-fidelity generalized method of cells micromechanics models to capture progressive failure within the constituents of a composite material while retaining objectivity with respect to the size of the discretization elements used in the model. An repeating unit cell containing 13 randomly arranged fibers is modeled and subjected to a combination of transverse tension/compression and transverse shear loading. The implementation is verified against experimental data (where available), and an equivalent finite element model utilizing the same implementation of the crack band theory. To evaluate the performance of the crack band theory within a repeating unit cell that is more amenable to a multiscale implementation, a single fiber is modeled with generalized method of cells and high-fidelity generalized method of cells using a relatively coarse subcell mesh which is subjected to the same loading scenarios as the multiple fiber repeating unit cell. The generalized method of cells and high-fidelity generalized method of cells models are validated against a very refined finite element model.

  16. An analysis of artificial viscosity effects on reacting flows using a spectral multi-domain technique

    NASA Technical Reports Server (NTRS)

    Macaraeg, M. G.; Streett, C. L.; Hussaini, M. Y.

    1987-01-01

    Standard techniques used to model chemically-reacting flows require an artificial viscosity for stability in the presence of strong shocks. The resulting shock is smeared over at least three computational cells, so that the thickness of the shock is dictated by the structure of the overall mesh and not the shock physics. A gas passing through a strong shock is thrown into a nonequilibrium state and subsequently relaxes down over some finite distance to an equilibrium end state. The artificial smearing of the shock envelops this relaxation zone which causes the chemical kinetics of the flow to be altered. A method is presented which can investigate these issues by following the chemical kinetics and flow kinetics of a gas passing through a fully resolved shock wave at hypersonic Mach numbers. A nonequilibrium chemistry model for air is incorporated into a spectral multidomain Navier-Stokes solution method. Since no artificial viscosity is needed for stability of the multidomain technique, the precise effect of this artifice on the chemical kinetics and relevant flow features can be determined.

  17. Young Singaporean women's knowledge of cervical cancer and pap smear screening: a descriptive study.

    PubMed

    Shea, Juanna; Klainin-Yobas, Piyanee; Mackey, Sandra

    2013-12-01

    To assess the knowledge of young female Singaporeans regarding cervical cancer and pap smear, the intention to participate in pap smear and whether there is any relationship between knowledge and intention to participate in pap smear screening. While cervical cancer has poor prognosis in the later stages, pap smear is effective in identifying precancerous lesions, which are more treatable. Pap smear screening is available to women in Singapore, but its uptake is opportunistic. Research has shown that knowledge about pap smear and cervical cancer is important determinant of screening behaviour in Singaporean women. Cross-sectional descriptive correlational design was used. Three hundred and ninety-three young Singaporean undergraduates, aged 18-25 years, were recruited via convenience sampling from a local university over a four-month period. Data were collected through self-administered questionnaires. Majority of the participants knew the term 'pap smear' and its function. However, knowledge of the risk factors for cervical cancer was lacking among the young women. Knowledge of pap smear and cervical cancer had a weak correlation with the intention to go for the future uptake of pap smear. Educational efforts among younger Singaporean women on the knowledge of pap smear and risk factors for cervical cancer are needed. Improving knowledge will enable them to understand the importance of reducing exposure to risk factors and regular pap smear screening. All health professionals working with young Asian women should be prepared to educate and counsel young women to participate in pap smear screening according to current guidelines. In particular, knowledge of the age to attend the first pap smear and the recommended frequency for screening need to be targeted for health education. © 2013 John Wiley & Sons Ltd.

  18. Effect of ground control mesh on dust sampling and explosion mitigation.

    PubMed

    Alexander, D W; Chasko, L L

    2015-07-01

    Researchers from the National Institute for Occupational Safety and Health's Office of Mine Safety and Health Research conducted an assessment of the effects that ground control mesh might have on rock and float coal dust distribution in a coal mine. The increased use of mesh to control roof and rib spall introduces additional elevated surfaces on which rock or coal dust can collect. It is possible to increase the potential for dust explosion propagation if any float coal dust is not adequately inerted. In addition, the mesh may interfere with the collection of representative dust samples when using the pan-and-brush sampling method developed by the U.S. Bureau of Mines and used by the Mine Safety and Health Administration for band sampling. This study estimates the additional coal or rock dust that could accumulate on mesh and develops a means to collect representative dust samples from meshed entries.

  19. Effect of ground control mesh on dust sampling and explosion mitigation

    PubMed Central

    Alexander, D.W.; Chasko, L.L.

    2017-01-01

    Researchers from the National Institute for Occupational Safety and Health’s Office of Mine Safety and Health Research conducted an assessment of the effects that ground control mesh might have on rock and float coal dust distribution in a coal mine. The increased use of mesh to control roof and rib spall introduces additional elevated surfaces on which rock or coal dust can collect. It is possible to increase the potential for dust explosion propagation if any float coal dust is not adequately inerted. In addition, the mesh may interfere with the collection of representative dust samples when using the pan-and-brush sampling method developed by the U.S. Bureau of Mines and used by the Mine Safety and Health Administration for band sampling. This study estimates the additional coal or rock dust that could accumulate on mesh and develops a means to collect representative dust samples from meshed entries. PMID:28936000

  20. Fog collecting biomimetic surfaces: Influence of microstructure and wettability.

    PubMed

    Azad, M A K; Ellerbrok, D; Barthlott, W; Koch, K

    2015-01-19

    We analyzed the fog collection efficiency of three different sets of samples: replica (with and without microstructures), copper wire (smooth and microgrooved) and polyolefin mesh (hydrophilic, superhydrophilic and hydrophobic). The collection efficiency of the samples was compared in each set separately to investigate the influence of microstructures and/or the wettability of the surfaces on fog collection. Based on the controlled experimental conditions chosen here large differences in the efficiency were found. We found that microstructured plant replica samples collected 2-3 times higher amounts of water than that of unstructured (smooth) samples. Copper wire samples showed similar results. Moreover, microgrooved wires had a faster dripping of water droplets than that of smooth wires. The superhydrophilic mesh tested here was proved more efficient than any other mesh samples with different wettability. The amount of collected fog by superhydrophilic mesh was about 5 times higher than that of hydrophilic (untreated) mesh and was about 2 times higher than that of hydrophobic mesh.

  1. Mesh-size effects on drift sample composition as determined with a triple net sampler

    USGS Publications Warehouse

    Slack, K.V.; Tilley, L.J.; Kennelly, S.S.

    1991-01-01

    Nested nets of three different mesh apertures were used to study mesh-size effects on drift collected in a small mountain stream. The innermost, middle, and outermost nets had, respectively, 425 ??m, 209 ??m and 106 ??m openings, a design that reduced clogging while partitioning collections into three size groups. The open area of mesh in each net, from largest to smallest mesh opening, was 3.7, 5.7 and 8.0 times the area of the net mouth. Volumes of filtered water were determined with a flowmeter. The results are expressed as (1) drift retained by each net, (2) drift that would have been collected by a single net of given mesh size, and (3) the percentage of total drift (the sum of the catches from all three nets) that passed through the 425 ??m and 209 ??m nets. During a two day period in August 1986, Chironomidae larvae were dominant numerically in all 209 ??m and 106 ??m samples and midday 425 ??m samples. Large drifters (Ephemerellidae) occurred only in 425 ??m or 209 ??m nets, but the general pattern was an increase in abundance and number of taxa with decreasing mesh size. Relatively more individuals occurred in the larger mesh nets at night than during the day. The two larger mesh sizes retained 70% of the total sediment/detritus in the drift collections, and this decreased the rate of clogging of the 106 ??m net. If an objective of a sampling program is to compare drift density or drift rate between areas or sampling dates, the same mesh size should be used for all sample collection and processing. The mesh aperture used for drift collection should retain all species and life stages of significance in a study. The nested net design enables an investigator to test the adequacy of drift samples. ?? 1991 Kluwer Academic Publishers.

  2. Effect of surface condition to temperature distribution in living tissue during cryopreservation

    NASA Astrophysics Data System (ADS)

    Nozawa, M.; Hatakeyama, S.; Sugimoto, Y.; Sasaki, H.

    2017-12-01

    The temperature distribution of the simulated living tissue is measured for the improvement of the cooling rate during cryopreservation when the surface condition of the test sample is changed by covering the stainless steel mesh. Agar is used as a simulated living tissue and is filled inside the test sample. The variation of the transient temperature with mesh by the directly immersion in the liquid nitrogen is measured. The temperatures on the sample surface and the inside of the sample are measured by use of type T thermocouples. It is confirmed that on the sample surface there is the slightly temperature increase than that in the saturated liquid nitrogen at the atmospheric pressure. It is found by the comparison of the degree of superheat with or without the mesh that the surface temperature of the test sample with the mesh is lower than that without the mesh. On the other hand, the time series variations of the temperature located in the center of the sample does not change with or without the mesh. It is considered that the center of the sample used is too deep from the surface to respond to the boiling state on the sample surface.

  3. Biomechanical and Histologic Evaluation of LifeMesh™: A Novel Self-Fixating Mesh Adhesive.

    PubMed

    Shahan, Charles P; Stoikes, Nathaniel N; Roan, Esra; Tatum, James; Webb, David L; Voeller, Guy R

    2018-04-01

    Mesh fixation with the use of adhesives results in an immediate and total surface area adhesion of the mesh, removing the need for penetrating fixation points. The purpose of this study was to evaluate LifeMesh™, a prototype mesh adhesive technology which coats polypropylene mesh. The strength of the interface between mesh and tissue, inflammatory responses, and histology were measured at varying time points in a swine model, and these results were compared with sutures. Twenty Mongrel swine underwent implantation of LifeMesh™ and one piece of bare polypropylene mesh secured with suture (control). One additional piece of either LifeMesh™ or control was used for histopathologic evaluation. The implants were retrieved at 3, 7, and 14 days. Only 3- and 7-day specimens underwent lap shear testing. On Day 3, LifeMesh™ samples showed considerably less contraction than sutured samples. The interfacial strength of Day 3 LifeMesh™ samples was similar to that of sutured samples. At seven days, LifeMesh™ samples continued to show significantly less contraction than sutured samples. The strength of fixation at seven days was greater in the control samples. The histologic findings were similar in LifeMesh™ and control samples. LifeMesh™ showed significantly less contraction than sutured samples at all measured time points. Although fixation strength was similar at three days, the interfacial strength of LifeMesh™ remained unchanged, whereas sutured controls increased by day 7. With histologic equivalence, considerably less contraction, and similar early fixation strength, LifeMesh™ is a viable mesh fixation technology.

  4. Comparative study of two protocols for quantitative image-analysis of serotonin transporter clustering in lymphocytes, a putative biomarker of therapeutic efficacy in major depression.

    PubMed

    Romay-Tallon, Raquel; Rivera-Baltanas, Tania; Allen, Josh; Olivares, Jose M; Kalynchuk, Lisa E; Caruncho, Hector J

    2017-01-01

    The pattern of serotonin transporter clustering on the plasma membrane of lymphocytes extracted from human whole blood samples has been identified as a putative biomarker of therapeutic efficacy in major depression. Here we evaluated the possibility of performing a similar analysis using blood smears obtained from rats, and from control human subjects and depression patients. We hypothesized that we could optimize a protocol to make the analysis of serotonin protein clustering in blood smears comparable to the analysis of serotonin protein clustering using isolated lymphocytes. Our data indicate that blood smears require a longer fixation time and longer times of incubation with primary and secondary antibodies. In addition, one needs to optimize the image analysis settings for the analysis of smears. When these steps are followed, the quantitative analysis of both the number and size of serotonin transporter clusters on the plasma membrane of lymphocytes is similar using both blood smears and isolated lymphocytes. The development of this novel protocol will greatly facilitate the collection of appropriate samples by eliminating the necessity and cost of specialized personnel for drawing blood samples, and by being a less invasive procedure. Therefore, this protocol will help us advance the validation of membrane protein clustering in lymphocytes as a biomarker of therapeutic efficacy in major depression, and bring it closer to its clinical application.

  5. Evaluation of GeneXpert MTB/RIF for detection of pulmonary tuberculosis at peripheral tuberculosis clinics.

    PubMed

    Shao, Yan; Peng, Hong; Chen, Cheng; Zhu, Tao; Ji, Ming; Jiang, Wei; Zhu, Wei; Zhai, Xiang Jun; Lu, Wei

    2017-04-01

    Tuberculosis is one of the most common infectious diseases in China, while delayed patient finding obstructed disease control, especially for smear-negative patients. The current study was undertaken to evaluate the diagnostic accuracy of GeneXpert MTB/RIF compared with conventional methods in the detection of pulmonary tuberculosis patients. A total of 295 spot sputum samples from confirmed pulmonary tuberculosis patients were evaluated from September 2014 to June 2015. Each sample was examined by acid-fast bacillus smear microscopy, culture and GeneXpert MTB/RIF. The sputum culture on Löwenstein-Jensen (L-J) was considered as the gold-standard. After testing by smear, 68.81% (203/295) was negative and 31.19% (92/295) was positive. As the gold-standard, L-J culture detected 37.97% (112/295) positive of all specimens, while the positivity for GeneXpert MTB/RIF was 46.44% (137/295). Compared with L-J culture, the combined sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for GeneXpert MTB/RIF were 94.64%, 82.97%, 77.37% and 96.18% respectively. For smear-negative specimens, the sensitivity, specificity, PPV and NPV for GeneXpert MTB/RIF were 96.00%, 83.05%, 44.44% and 99.32%; while for smear-positive specimens, the corresponding accuracy values were 94.25%, 80.00%, 98.80% and 44.44%. The findings of study indicated that GeneXpert MTB/RIF assay demonstrated a high sensitivity in detecting Mycobacterium tuberculosis compared to smear method and a high NPV among smear negative patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A multisite assessment of the quantitative capabilities of the Xpert MTB/RIF assay.

    PubMed

    Blakemore, Robert; Nabeta, Pamela; Davidow, Amy L; Vadwai, Viral; Tahirli, Rasim; Munsamy, Vanisha; Nicol, Mark; Jones, Martin; Persing, David H; Hillemann, Doris; Ruesch-Gerdes, Sabine; Leisegang, Felicity; Zamudio, Carlos; Rodrigues, Camilla; Boehme, Catharina C; Perkins, Mark D; Alland, David

    2011-11-01

    The Xpert MTB/RIF is an automated molecular test for Mycobacterium tuberculosis that estimates bacterial burden by measuring the threshold-cycle (Ct) of its M. tuberculosis-specific real-time polymerase chain reaction. Bacterial burden is an important biomarker for disease severity, infection control risk, and response to therapy. Evaluate bacterial load quantitation by Xpert MTB/RIF compared with conventional quantitative methods. Xpert MTB/RIF results were compared with smear-microscopy, semiquantiative solid culture, and time-to-detection in liquid culture for 741 patients and 2,008 samples tested in a multisite clinical trial. An internal control real-time polymerase chain reaction was evaluated for its ability to identify inaccurate quantitative Xpert MTB/RIF results. Assays with an internal control Ct greater than 34 were likely to be inaccurately quantitated; this represented 15% of M. tuberculosis-positive tests. Excluding these, decreasing M. tuberculosis Ct was associated with increasing smear microscopy grade for smears of concentrated sputum pellets (r(s) = -0.77) and directly from sputum (r(s) =-0.71). A Ct cutoff of approximately 27.7 best predicted smear-positive status. The association between M. tuberculosis Ct and time-to-detection in liquid culture (r(s) = 0.68) and semiquantitative colony counts (r(s) = -0.56) was weaker than smear. Tests of paired same-patient sputum showed that high viscosity sputum samples contained ×32 more M. tuberculosis than nonviscous samples. Comparisons between the grade of the acid-fast bacilli smear and Xpert MTB/RIF quantitative data across study sites enabled us to identify a site outlier in microscopy. Xpert MTB/RIF quantitation offers a new, standardized approach to measuring bacterial burden in the sputum of patients with tuberculosis.

  7. Factors which contributed for low quality sputum smears for the detection of acid fast bacilli (AFB) at selected health centers in Ethiopia: A quality control perspective.

    PubMed

    Mekonen, Ayehu; Ayele, Yeshi; Berhan, Yifru; Woldeyohannes, Desalegn; Erku, Woldaregay; Sisay, Solomon

    2018-01-01

    Quality of tuberculosis (TB) microscopy diagnosis is not a guarantee despite implementation of External Quality Assurance (EQA) service in all laboratories of health facilities. Hence, we aimed at evaluating the technical quality and the findings of sputum smear microscopy for acid fast bacilli (AFB) at health centers in Hararge Zone, Oromia Region, Ethiopia. A cross-sectional study was carried out between July 8, 2014 and July 7, 2015.A pre-tested structured questionnaire was used to collect data. Lot Quality Assurance Sampling (LQAS) method was put into practice for collecting all necessary sample slides. Data were analyzed by using SPSS (Statistical Package for Social Sciences) version 20 software. P-value < 0.05 was considered as statistically significant. Of the total55 health center laboratories which had been assessed during the study period, 20 (36.4%) had major technical errors; 13 (23.6%) had 15 false negative results and 17 (30.9%) had 22 false positive results. Moreover, poor specimen quality, smear size, smear thickness, staining and evenness were indicated in 40 (72.7%), 39 (70.9%), 37 (67.3%), 27(49.1%) and 37 (67.3%) of the collected samples, respectively. False negative AFB findings were significantly associated with lack of Internal Quality Control (IQC) measures (AOR (Adjusted Odds Ratio): 2.90 (95% CI (Confidence Interval): 1.25,6.75) and poor staining procedures (AOR: 2.16(95% CI: 1.01, 5.11). The qualities of AFB smear microscopy reading and smearing were low in most of the laboratories of the health centers. Therefore, it is essential to strength EQA program through building the capacity of laboratory professionals.

  8. Compressive and Flexural Tests on Adobe Samples Reinforced with Wire Mesh

    NASA Astrophysics Data System (ADS)

    Jokhio, G. A.; Al-Tawil, Y. M. Y.; Syed Mohsin, S. M.; Gul, Y.; Ramli, N. I.

    2018-03-01

    Adobe is an economical, naturally available, and environment friendly construction material that offers excellent thermal and sound insulations as well as indoor air quality. It is important to understand and enhance the mechanical properties of this material, where a high degree of variation is reported in the literature owing to lack of research and standardization in this field. The present paper focuses first on the understanding of mechanical behaviour of adobe subjected to compressive stresses as well as flexure and then on enhancing the same with the help of steel wire mesh as reinforcement. A total of 22 samples were tested out of which, 12 cube samples were tested for compressive strength, whereas 10 beams samples were tested for modulus of rupture. Half of the samples in each category were control samples i.e. without wire mesh reinforcement, whereas the remaining half were reinforced with a single layer of wire mesh per sample. It has been found that the compressive strength of adobe increases by about 43% after adding a single layer of wire mesh reinforcement. The flexural response of adobe has also shown improvement with the addition of wire mesh reinforcement.

  9. Evaluation of final irrigation regimens with maleic acid for smear layer removal and wettability of root canal sealer.

    PubMed

    Ballal, Nidambur Vasudev; Ferrer-Luque, Carmen Maria; Sona, Mrunali; Prabhu, K Narayan; Arias-Moliz, Teresa; Baca, Pilar

    2018-04-01

    To evaluate the smear layer removal and wettability of AH Plus sealer on root canal dentin treated with MA (maleic acid), MA + CTR (cetrimide) and MA + CTR + CHX (chlorhexidine) as final irrigating regimens. For smear layer removal, 40 teeth were instrumented to size F4 and divided into four groups: (1) 7% MA, (2) 7% MA + 0.2% CTR, (3) 7% MA + 0.2% CTR + 2% CHX, (4) distilled water (control). After irrigation, teeth were subjected to SEM analysis. For contact angle analysis, 20 teeth were split longitudinally and divided into four groups similar to smear layer analysis. AH plus sealer was placed on each specimen and contact angle was analysed. In both smear layer (p = .393) and contact angle analysis (p = .961), there was no significant difference between the groups MA and MA + CTR. However, MA + CTR + CHX removed smear layer less effectively (p = .023) and increased the contact angle of the sealer (p = .005). In smear layer analysis, specimens in negative control group were heavily smeared. In case of contact angle analysis, samples in the control group had least contact angle. MA alone or in combination with CTR removed smear layer effectively and increased the wettability of AH plus sealer to root canal dentin.

  10. Single step modified ink staining for Tzanck test: quick detection of herpetic giant cells in Tzanck smear.

    PubMed

    Mizutani, Hitoshi; Akeda, Tomoko; Yamanaka, Kei-Ichi; Isoda, Kenichi; Gabazza, Esteban C

    2012-02-01

    Tzanck test has been recently re-evaluated as a method for the diagnosis of herpes virus infection. Giemsa staining for the Tzanck test is time-consuming and laborious. There is a need to develop simple and quick staining methods for bedside diagnosis of this disease. We report a single step and quick method for staining herpes giant cells in Tzanck smears using routinely available inks and physiological saline. A keratinocyte cell line (HaCaT) was cultured on a slide glass and stained with various commercially available blue, blue-black and black inks serially diluted with physiological saline. Clinical smear samples from herpes lesions were also stained with these solutions without specific pretreatment. The nuclei of HaCaT were clearly stained showing high contrast with the cytoplasm using 5% Parker-Quink blue-black ink saline solution. Concentration of ink solution higher or lower than 5% resulted in less contrast. Blue or black inks or other manufacturers' inks can also be used, but staining of the cultured keratinocytes was less clear. Smear of clinical samples from herpes lesions were also stained with 5% ink solution. The nuclei of the multinucleated giant cells were clearly stained, and the sample could be immediately used for microscopic examination. One step staining of Tzanck smear using this diluted ink solution is an inexpensive and a convenient bedside diagnostic tool for the dermatologist. © 2011 Japanese Dermatological Association.

  11. A first insight into high prevalence of undiagnosed smear-negative pulmonary tuberculosis in Northern Ethiopian prisons: implications for greater investment and quality control.

    PubMed

    Biadglegne, Fantahun; Rodloff, Arne C; Sack, Ulrich

    2014-01-01

    Tuberculosis (TB) transmission in prisons poses significant risks to inmates as well as the general population. Currently, there are no data on smear-negative pulmonary TB cases in prisons and by extension no data on the impact such cases have on TB incidence. This study was designed to obtain initial data on the prevalence of smear-negative cases of TB in prisons as well as preliminary risk factor analysis for such TB cases. This cross-sectional survey was conducted in November 2013 at eight main prisons located in the state of Amhara, Ethiopia. Interviews using a structured and pretested questionnaire were done first to identify symptomatic prisoners. Three consecutive sputum samples were collected and examined using acid fast bacilli (AFB) microscopy at the point of care. All smear-negative sputum samples were taken for culture and Xpert testing. Descriptive and multivariate analysis was done using SPSS version 16. Overall the prevalence of smear-negative pulmonary TB cases in the study prisons was 8% (16/200). Using multivariate analysis, a contact history to TB patients in prison, educational level, cough and night sweating were found to be predictors of TB positivity among smear-negative pulmonary TB cases (p ≤ 0.05). In the studied prisons, high prevalence of undiagnosed TB cases using AFB microscopy was documented, which is an important public health concern that urgently needs to be addressed. Furthermore, patients with night sweating, non-productive cough, a contact history with TB patients and who are illiterate merit special attention, larger studies are warranted in the future to assess the associations more precisely. Further studies are also needed to examine TB transmission dynamics by patients with smear-negative pulmonary TB in a prison setting.

  12. Evaluation of Loopamp™MTBC detection kit for diagnosis of pulmonary tuberculosis at a peripheral laboratory in a high burden setting.

    PubMed

    Nguyen, Van Anh Thi; Nguyen, Hung Van; Dinh, Thuong Van; Du, Ha Hoang; Do, Chinh Nhu; Marks, Guy B; Nguyen, Nhung Viet

    2018-03-01

    The Loopamp™MTBC detection kit (TB-LAMP) was designed to replace the sputum smear microscopy for the diagnosis of pulmonary tuberculosis. We evaluated its performance at a peripheral laboratory in Vietnam. The sensitivity of TB-LAMP was 45.5% (28.1%-63.6%), which was equal to 3-sputum smear microscopy but lower than that of Xpert MTB/RIF (87.8% [71.8%-96.6%]). In patients with culture-confirmed TB, sensitivity was 80% (51.9%-95.7%) in smear-positive and 16.7% (3.5%-41.4%) in smear-negative cases. The specificity of TB-LAMP was 95.1% (92.7%-96.9%), which was lower than that of smear microscopy (98.9% [97.5%-99.7%]) and Xpert MTB/RIF (99.3% [98.1%-99.9%]) (P<0.05). The probability of TB detection by TB-LAMP was more influenced by sample quality and viscosity than were smear microscopy, Xpert MTB/RIF, and culture. The present data do not support the use of TB-LAMP as a replacement test for smear microscopy in peripheral laboratories. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. PAPNET-assisted primary screening of conventional cervical smears.

    PubMed

    Cenci, M; Nagar, C; Vecchione, A

    2000-01-01

    The PAPNET System is the only device with a neural-network-based-artificial intelligence to detect and show the images of abnormal cells on the monitor to be evaluated in an interactive way. We effectively used the PAPNET in rescreening of conventional cervical smears and we detected its advantages and its disadvantages. In this paper, we report our results from PAPNET-assisted primary screening performed on 20,154 conventional smears. The smears were classified as Negative or as Review. The Negative cases were rapidly rescreened mainly near the coverslip edges, which are the slide areas not analyzed by automated devices because of focusing problems. The Review cases were fully reanalyzed by the optic microscope. In summary, 140 positive smears were detected: 57 cases showed changes due to HPV, 63 LSIL, 15 HSIL, and 5 carcinomas. Therefore, the PAPNET System was confirmed as useful in primary screening of conventional cervical samples as well as rescreening.

  14. Relationship between automated total nucleated cell count and enumeration of cells on direct smears of canine synovial fluid.

    PubMed

    Dusick, Allison; Young, Karen M; Muir, Peter

    2014-12-01

    Canine osteoarthritis is a common disorder seen in veterinary clinical practice and causes considerable morbidity in dogs as they age. Synovial fluid analysis is an important tool for diagnosis and treatment of canine joint disease and obtaining a total nucleated cell count (TNCC) is particularly important. However, the low sample volumes obtained during arthrocentesis are often insufficient for performing an automated TNCC, thereby limiting diagnostic interpretation. The aim of the present study was to investigate whether estimation of TNCC in canine synovial fluid could be achieved by performing manual cell counts on direct smears of fluid. Fifty-eight synovial fluid samples, taken by arthrocentesis from 48 dogs, were included in the study. Direct smears of synovial fluid were prepared, and hyaluronidase added before cell counts were obtained using a commercial laser-based instrument. A protocol was established to count nucleated cells in a specific region of the smear, using a serpentine counting pattern; the mean number of nucleated cells per 400 × field was then calculated. There was a positive correlation between the automated TNCC and mean manual cell count, with more variability at higher TNCC. Regression analysis was performed to estimate TNCC from manual counts. By this method, 78% of the samples were correctly predicted to fall into one of three categories (within the reference interval, mildly to moderately increased, or markedly increased) relative to the automated TNCC. Intra-observer and inter-observer agreement was good to excellent. The results of the study suggest that interpretation of canine synovial fluid samples of low volume can be aided by methodical manual counting of cells on direct smears. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Increased detection of smear-negative pulmonary tuberculosis by GeneXpert MTB/RIF® assay after bleach concentration.

    PubMed

    Tadesse, Mulualem; Aragaw, Dossegnaw; Rigouts, Leen; Abebe, Gemeda

    2016-06-01

    The GeneXpert MTB/RIF assay (Xpert) was endorsed as the initial diagnostic tool in people suspected of human immunodeficiency virus-associated or drug-resistant tuberculosis (TB). However, information regarding the performance of Xpert for diagnosing smear-negative TB in high burden settings remains limited. We evaluated the diagnostic accuracy of Xpert and the impact of bleach concentration on the performance of Xpert using smear-negative sputum samples from human immunodeficiency virus-negative patients. One spot and one morning smear-negative sputum samples per patient were examined using Xpert and culture at the Mycobacteriology Research Center of Jimma University, Ethiopia. The sputum culture on both Löwenstein-Jensen and/or Mycobacteria Growth Indicator Tube was the gold-standard. Of 185 smear-negative presumptive pulmonary TB cases, 19 (10.3%) had culture-proven TB. The sensitivity of Xpert on spot and morning sputum was similar (63.2%). Testing two specimens per patient insignificantly increased the sensitivity of Xpert. Bleach concentration and pelleting improved the sensitivity of Xpert over unprocessed sputum in paired samples (73.8% vs. 63.2%) without affecting the specificity (95%). Bleach concentration and pelleting allowed an additional seven cases of TB (missed on the first and second direct Xperts) to be detected, five of which were from culture-negative cases. Testing of a single sputum sample by Xpert can reach reasonable sensitivity and results would be available on the same day, avoiding loss of patients and treatment delay. The sensitivity of Xpert was improved after bleach concentration and pelleting, although its added value needs further study on a larger scale. Copyright © 2016 Asian-African Society for Mycobacteriology. Published by Elsevier Ltd. All rights reserved.

  16. Assessment of the sensitivity and specificity of Xpert MTB/RIF assay as an early sputum biomarker of response to tuberculosis treatment.

    PubMed

    Friedrich, Sven O; Rachow, Andrea; Saathoff, Elmar; Singh, Kasha; Mangu, Chacha D; Dawson, Rodney; Phillips, Patrick Pj; Venter, Amour; Bateson, Anna; Boehme, Catharina C; Heinrich, Norbert; Hunt, Robert D; Boeree, Martin J; Zumla, Alimuddin; McHugh, Timothy D; Gillespie, Stephen H; Diacon, Andreas H; Hoelscher, Michael

    2013-08-01

    An accurate biomarker is urgently needed to monitor the response to treatment in patients with pulmonary tuberculosis. The Xpert MTB/RIF assay is a commercially available real-time PCR that can be used to detect Mycobacterium-tuberculosis-specific DNA sequences in sputum samples. We therefore evaluated this assay with serial sputum samples obtained over 26 weeks from patients undergoing treatment for tuberculosis. We analysed sputum samples from 221 patients with smear-positive tuberculosis enrolled at two sites (Cape Town, South Africa, and Mbeya, Tanzania) of a multicentre randomised clinical trial REMoxTB of antituberculosis treatment on a weekly basis (weeks 0 to 8), then at weeks 12, 17, 22, and 26 after treatment initiation. The Xpert MTB/RIF results over time were compared with the results of standard smear microscopy and culture methods. We obtained and analysed 2741 sputum samples from 221 patients. The reduction in positivity rates with Xpert MTB/RIF were slower than those with the standard methods. At week 8, positive results were obtained for 62 (29%) of 212 sputum samples with smear microscopy, 46 (26%) of 175 with solid culture (Löwenstein-Jensen medium), 77 (42%) of 183 with liquid culture (Bactec MGIT960 system), and 174 (84%) of 207 with Xpert MTB/RIF; at 26 weeks, positive results were obtained for ten (5%) of 199, four (3%) of 157, seven (4%) of 169, and 22 (27%) of 83 sputum samples, respectively. The reduction in detection of quantitative M tuberculosis DNA with Xpert MTB/RIF correlated with smear grades (ρ=-0·74; p<0·0001), solid culture grades (ρ=-0·73; p<0·0001), and time to liquid culture positivity (ρ=0·73; p<0·0001). Compared with the combined binary smear and culture results as a reference standard, the Xpert MTB/RIF assay had high sensitivity (97·0%, 95% CI 95·8-97·9), but poor specificity (48·6%, 45·0-52·2). The poor specificity precludes the use of the Xpert MTB/RIF assay as a biomarker for monitoring tuberculosis treatment, and should not replace standard smear microscopy and culture. Global Alliance for TB Drug Development, Bill & Melinda Gates Foundation, UK Medical Research Council, German Ministry of Science and Technology. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Comparison of diagnostic performances among bronchoscopic sampling techniques in the diagnosis of peripheral pulmonary lesions.

    PubMed

    Boonsarngsuk, Viboon; Kanoksil, Wasana; Laungdamerongchai, Sarangrat

    2015-04-01

    There are many sampling techniques dedicated to radial endobronchial ultrasound (R-EBUS) guided flexible bronchoscopy (FB). However, data regarding the diagnostic performances among bronchoscopic sampling techniques is limited. This study was conducted to compare the diagnostic yields among bronchoscopic sampling techniques in the diagnosis of peripheral pulmonary lesions (PPLs). A prospective study was conducted on 112 patients who were diagnosed with PPLs and underwent R-EBUS-guided FB between Oct 2012 and Sep 2014. Sampling techniques-including transbronchial biopsy (TBB), brushing cell block, brushing smear, rinsed fluid of brushing, and bronchoalveolar lavage (BAL)-were evaluated for the diagnosis. The mean diameter of the PPLs was 23.5±9.5 mm. The final diagnoses included 76 malignancies and 36 benign lesions. The overall diagnostic yield of R-EBUS-guided bronchoscopy was 80.4%; TBB gave the highest yield among the 112 specimens: 70.5%, 34.8%, 62.5%, 50.0% and 42.0% for TBB, brushing cell block, brushing smear, rinsed brushing fluid, and BAL fluid (BALF), respectively (P<0.001). TBB provided high diagnostic yield irrespective of the size and etiology of the PPLs. The combination of TBB and brushing smear achieved the maximum diagnostic yield. Of 31 infectious PPLs, BALF culture gave additional microbiological information in 20 cases. TBB provided the highest diagnostic yield; however, to achieve the highest diagnostic performance, TBB, brushing smear and BAL techniques should be performed together.

  18. Spot sputum samples are at least as good as early morning samples for identifying Mycobacterium tuberculosis.

    PubMed

    Murphy, Michael E; Phillips, Patrick P J; Mendel, Carl M; Bongard, Emily; Bateson, Anna L C; Hunt, Robert; Murthy, Saraswathi; Singh, Kasha P; Brown, Michael; Crook, Angela M; Nunn, Andrew J; Meredith, Sarah K; Lipman, Marc; McHugh, Timothy D; Gillespie, Stephen H

    2017-10-27

    The use of early morning sputum samples (EMS) to diagnose tuberculosis (TB) can result in treatment delay given the need for the patient to return to the clinic with the EMS, increasing the chance of patients being lost during their diagnostic workup. However, there is little evidence to support the superiority of EMS over spot sputum samples. In this new analysis of the REMoxTB study, we compare the diagnostic accuracy of EMS with spot samples for identifying Mycobacterium tuberculosis pre- and post-treatment. Patients who were smear positive at screening were enrolled into the study. Paired sputum samples (one EMS and one spot) were collected at each trial visit pre- and post-treatment. Microscopy and culture on solid LJ and liquid MGIT media were performed on all samples; those missing corresponding paired results were excluded from the analyses. Data from 1115 pre- and 2995 post-treatment paired samples from 1931 patients enrolled in the REMoxTB study were analysed. Patients were recruited from South Africa (47%), East Africa (21%), India (20%), Asia (11%), and North America (1%); 70% were male, median age 31 years (IQR 24-41), 139 (7%) co-infected with HIV with a median CD4 cell count of 399 cells/μL (IQR 318-535). Pre-treatment spot samples had a higher yield of positive Ziehl-Neelsen smears (98% vs. 97%, P = 0.02) and LJ cultures (87% vs. 82%, P = 0.006) than EMS, but there was no difference for positivity by MGIT (93% vs. 95%, P = 0.18). Contaminated and false-positive MGIT were found more often with EMS rather than spot samples. Surprisingly, pre-treatment EMS had a higher smear grading and shorter time-to-positivity, by 1 day, than spot samples in MGIT culture (4.5 vs. 5.5 days, P < 0.001). There were no differences in time to positivity in pre-treatment LJ culture, or in post-treatment MGIT or LJ cultures. Comparing EMS and spot samples in those with unfavourable outcomes, there were no differences in smear or culture results, and positive results were not detected earlier in Kaplan-Meier analyses in either EMS or spot samples. Our data do not support the hypothesis that EMS samples are superior to spot sputum samples in a clinical trial of patients with smear positive pulmonary TB. Observed small differences in mycobacterial burden are of uncertain significance and EMS samples do not detect post-treatment positives any sooner than spot samples.

  19. Human Papillomavirus Type 16 Viral Load Is Higher in Human Immunodeficiency Virus-Seropositive Women with High-Grade Squamous Intraepithelial Lesions Than in Those with Normal Cytology Smears

    PubMed Central

    Lefevre, Jonas; Hankins, Catherine; Money, Deborah; Rachlis, Anita; Pourreaux, Karina; Coutlée, François

    2004-01-01

    Human papillomavirus type 16 (HPV-16) viral load in cervicovaginal lavage samples collected from 66 human immunodeficiency virus-seropositive women was inversely correlated with blood CD4 count (P = 0.002). HPV-16 viral load was 81-fold higher in women with cervical smears suggestive of high-grade lesions (median, 4,425,883 copies/μg of DNA) than in women with normal smears (median, 54,576), controlling for age (P = 0.006). PMID:15131192

  20. Diagnostic performance of automated liquid culture and molecular line probe assay in smear-negative pulmonary tuberculosis.

    PubMed

    Kotwal, Aarti; Biswas, Debasis; Raghuvanshi, Shailendra; Sindhwani, Girish; Kakati, Barnali; Sharma, Shweta

    2017-04-01

    The diagnosis of smear-negative pulmonary tuberculosis (PTB) is particularly challenging, and automated liquid culture and molecular line probe assays (LPA) may prove particularly useful. The objective of our study was to evaluate the diagnostic potential of automated liquid culture (ALC) technology and commercial LPA in sputum smear-negative PTB suspects. Spot sputum samples were collected from 145 chest-symptomatic smear-negative patients and subjected to ALC, direct drug susceptibility test (DST) testing and LPA, as per manufacturers' instructions. A diagnostic yield of 26.2% was observed among sputum smear-negative TB suspects with 47.4% of the culture isolates being either INH- and/or rifampicin-resistant. Complete agreement was observed between the results of ALC assay and LPA except for two isolates which demonstrated sensitivity to INH and rifampicin at direct DST but were rifampicin-resistant in LPA. Two novel mutations were also detected among the multidrug isolates by LPA. In view of the diagnostic challenges associated with the diagnosis of TB in sputum smear-negative patients, our study demonstrates the applicability of ALC and LPA in establishing diagnostic evidence of TB.

  1. Immunofluorescence of bovine virus diarrhea viral antigen in white blood cells from experimentally infected immunocompetent calves.

    PubMed Central

    Bezek, D M; Baker, J C; Kaneene, J B

    1988-01-01

    A study to evaluate the detection of bovine virus diarrhea viral antigen using immunofluorescence testing of white blood cells was conducted. Five colostrum-deprived calves were inoculated intravenously with a cytopathic strain of the virus. Lymphocyte and buffy coat smears were prepared daily for direct immunofluorescent staining for detection of antigen. Lymphocytes were separated from heparinized blood using a Ficoll density procedure. Buffy coat smears were prepared from centrifuged blood samples collected using ethylenediaminetetraacetic acid as an anticoagulant. Bovine viral diarrhea virus antigen was detected by immunofluorescence between 3 and 11 days postinfection in lymphocyte smears and 3 to 12 days postinfection in buffy coat smears. Isolation of virus from both lymphocytes and buffy coat preparations correlated with detection of immunofluorescence. Serum neutralizing antibody to bovine virus diarrhea virus was detected on day 10 postinfection. Buffy coat smears were as sensitive as lymphocyte smears for the detection of antigen by immunofluorescence. It appeared that immunofluorescent staining of white blood cells was an effective method of detecting bovine virus diarrhea viral antigen. PMID:2836047

  2. Low cost automated whole smear microscopy screening system for detection of acid fast bacilli.

    PubMed

    Law, Yan Nei; Jian, Hanbin; Lo, Norman W S; Ip, Margaret; Chan, Mia Mei Yuk; Kam, Kai Man; Wu, Xiaohua

    2018-01-01

    In countries with high tuberculosis (TB) burden, there is urgent need for rapid, large-scale screening to detect smear-positive patients. We developed a computer-aided whole smear screening system that focuses in real-time, captures images and provides diagnostic grading, for both bright-field and fluorescence microscopy for detection of acid-fast-bacilli (AFB) from respiratory specimens. To evaluate the performance of dual-mode screening system in AFB diagnostic algorithms on concentrated smears with auramine O (AO) staining, as well as direct smears with AO and Ziehl-Neelsen (ZN) staining, using mycobacterial culture results as gold standard. Adult patient sputum samples requesting for M. tuberculosis cultures were divided into three batches for staining: direct AO-stained, direct ZN-stained and concentrated smears AO-stained. All slides were graded by an experienced microscopist, in parallel with the automated whole smear screening system. Sensitivity and specificity of a TB diagnostic algorithm in using the screening system alone, and in combination with a microscopist, were evaluated. Of 488 direct AO-stained smears, 228 were culture positive. These yielded a sensitivity of 81.6% and specificity of 74.2%. Of 334 direct smears with ZN staining, 142 were culture positive, which gave a sensitivity of 70.4% and specificity of 76.6%. Of 505 concentrated smears with AO staining, 250 were culture positive, giving a sensitivity of 86.4% and specificity of 71.0%. To further improve performance, machine grading was confirmed by manual smear grading when the number of AFBs detected fell within an uncertainty range. These combined results gave significant improvement in specificity (AO-direct:85.4%; ZN-direct:85.4%; AO-concentrated:92.5%) and slight improvement in sensitivity while requiring only limited manual workload. Our system achieved high sensitivity without substantially compromising specificity when compared to culture results. Significant improvement in specificity was obtained when uncertain results were confirmed by manual smear grading. This approach had potential to substantially reduce workload of microscopists in high burden countries.

  3. Diagnostic utility of a line probe assay for multidrug resistant-TB in smear-negative pulmonary tuberculosis.

    PubMed

    Singh, Binit Kumar; Sharma, Surendra K; Sharma, Rohini; Sreenivas, Vishnubhatla; Myneedu, Vithal P; Kohli, Mikashmi; Bhasin, Dinkar; Sarin, Sanjay

    2017-01-01

    To evaluate the performance of Genotype MTBDRplus VER 2.0 in the diagnosis of Mycobacterium tuberculosis (MTB) in sputum smear-negative pulmonary TB cases. A total of 572 Ziehl-Neelsen sputum smear-negative samples were selected and subjected to line probe assay (Genotype MTBDRplus VER 2.0), and culture in mycobacterial growth indicator tube (MGIT-960). Immunochromatographic test was used to confirm the MTB-complex (MTBC) in culture-positive samples and phenotypic drug-susceptibility testing was done using MGIT-960. The line probe assay was able to diagnose MTBC in 38.2% (213/558) of specimens after excluding 14 nontuberculous mycobacteria. Sensitivity and specificity of the assay were 68.4% and 89.3% respectively, considering MGIT-960 culture as gold standard after excluding contaminated and invalid results. On comparing with composite reference standard, the assay had 71.5% sensitivity and 100% specificity in the diagnosis of tuberculosis. The sensitivity and specificity for detecting resistance to rifampicin (RMP) were 100% and 99.24% respectively and for resistance to isoniazid (INH) were 97.62% and 98.55%, respectively. Genotype MTBDRplus VER 2.0 is a rapid and precise diagnostic tool for detection of MTB in sputum smear-negative samples. It also facilitates accurate diagnosis of RMP and INH resistance within turn around-time.

  4. Diagnosis of Pulmonary Tuberculosis in HIV-Positive Patients by Microscopic Observation Drug Susceptibility Assay ▿

    PubMed Central

    Ha, Dang Thi Minh; Lan, Nguyen Thi Ngoc; Kiet, Vo Sy; Wolbers, Marcel; Hang, Hoang Thi Thanh; Day, Jeremy; Hien, Nguyen Quang; Tien, Nguyen Anh; An, Pham Thuy; Anh, Truong Thi; Oanh, Do Thi Tuong; Hoa, Chau Luong; Chau, Nguyen Thi Minh; Hai, Nguyen Ngoc; Binh, Ngo Thanh; Ngoc, Le Hong; Phuong, Doan Thanh; Quyet, Tran Van; Tuyen, Nguyen Thi Bich; Ha, Vo Thi; Nho, Nguyen Thi; Hoa, Dai Viet; Anh, Phan Thi Hoang; Dung, Nguyen Huy; Farrar, Jeremy; Caws, Maxine

    2010-01-01

    The microscopic observation drug susceptibility assay (MODS) is a novel and promising test for the early diagnosis of tuberculosis (TB). We evaluated the MODS assay for the early diagnosis of TB in HIV-positive patients presenting to Pham Ngoc Thach Hospital for Tuberculosis and Lung Diseases in southern Vietnam. A total of 738 consecutive sputum samples collected from 307 HIV-positive individuals suspected of TB were tested by smear, MODS, and the mycobacteria growth indicator tube method (MGIT). The diagnostic sensitivity and specificity of MODS compared to the microbiological gold standard (either smear or MGIT) were 87 and 93%, respectively. The sensitivities of smear, MODS, and MGIT were 57, 71, and 75%, respectively, against clinical gold standard (MODS versus smear, P < 0.001; MODS versus MGIT, P = 0.03). The clinical gold standard was defined as patients who had a clinical examination and treatment consistent with TB, with or without microbiological confirmation. For the diagnosis of smear-negative patients, the sensitivities of MODS and MGIT were 38 and 45%, respectively (P = 0.08). The median times to detection using MODS and MGIT were 8 and 11 days, respectively, and they were 11 and 17 days, respectively, for smear-negative samples. The original bacterial/fungal contamination rate of MODS was 1.1%, while it was 2.6% for MGIT. The cross-contamination rate of MODS was 4.7%. In conclusion, MODS is a sensitive, specific, and rapid test that is appropriate for the detection of HIV-associated TB; its cost and ease of use make it particularly useful in resource-limited settings. PMID:20926704

  5. Thick Smear is a Good Substitute for the Thin Smear in Parasitological Confirmation of Canine Visceral Leishmaniasis.

    PubMed

    de Mello, Cintia Xavier; Figueiredo, Fabiano Borges; Mendes Júnior, Artur Augusto Velho; Miranda, Luciana de Freitas Campos; de Oliveira, Raquel de Vasconcellos Carvalhaes; Madeira, Maria de Fátima

    2016-07-06

    Although direct examination methods are important for diagnosing leishmaniasis, such methods are often neglected because of their low sensitivity relative to other techniques. Our study aimed to evaluate the performance of bone marrow (BM) thick smears and cytocentrifugation tests as alternatives to direct examination for diagnosing canine visceral leishmaniasis (CVL). Ninety-two dogs exhibiting leishmaniasis seroreactivity were evaluated. The animals were euthanized; and healthy skin, spleen, popliteal lymph node, and BM puncture samples were cultured. BM cultures were used as the reference standard. Of the 92 dogs studied, 85.9% exhibited positive cultures, and Leishmania infantum (synonym Leishmania chagasi) was confirmed in all positive culture cases. The sensitivity rates for cytocentrifugation as well as thin and thick smears were 47.1%, 52.8%, and 77%, respectively. However, no association between the dogs' clinical status and culture or direct examination results was found. To our knowledge, this was the first study to use thick smears and cytocentrifugation for diagnosing CVL. Our results indicate that BM thick smears have a good sensitivity and their use reduces the time required to read slides. Therefore, thick smears can provide a rapid and safe alternative to parasitological confirmation of seroreactive dogs. © The American Society of Tropical Medicine and Hygiene.

  6. LED Fluorescence Microscopy for the Diagnosis of Pulmonary Tuberculosis: A Multi-Country Cross-Sectional Evaluation

    PubMed Central

    Cuevas, Luis Eduardo; Al-Sonboli, Najla; Lawson, Lovett; Yassin, Mohammed Ahmed; Arbide, Isabel; Al-Aghbari, Nasher; Bahadur Sherchand, Jeevan; Al-Absi, Amin; Emenyonu, Emmanuel Nnamdi; Merid, Yared; Okobi, Mosis Ifenyi; Onuoha, Juliana Olubunmi; Aschalew, Melkamsew; Aseffa, Abraham; Harper, Greg; Anderson de Cuevas, Rachel Mary; Theobald, Sally Jane; Nathanson, Carl-Michael; Joly, Jean; Faragher, Brian; Squire, Stephen Bertel; Ramsay, Andrew

    2011-01-01

    Background The diagnosis of tuberculosis (TB) in resource-limited settings relies on Ziehl-Neelsen (ZN) smear microscopy. LED fluorescence microscopy (LED-FM) has many potential advantages over ZN smear microscopy, but requires evaluation in the field. The aim of this study was to assess the sensitivity/specificity of LED-FM for the diagnosis of pulmonary TB and whether its performance varies with the timing of specimen collection. Methods and Findings Adults with cough ≥2 wk were enrolled consecutively in Ethiopia, Nepal, Nigeria, and Yemen. Sputum specimens were examined by ZN smear microscopy and LED-FM and compared with culture as the reference standard. Specimens were collected using a spot-morning-spot (SMS) or spot-spot-morning (SSM) scheme to explore whether the collection of the first two smears at the health care facility (i.e., “on the spot”) the first day of consultation followed by a morning sample the next day (SSM) would identify similar numbers of smear-positive patients as smears collected via the SMS scheme (i.e., one on-the-spot-smear the first day, followed by a morning specimen collected at home and a second on-the-spot sample the second day). In total, 529 (21.6%) culture-positive and 1,826 (74.6%) culture-negative patients were enrolled, of which 1,156 (49%) submitted SSM specimens and 1,199 (51%) submitted SMS specimens. Single LED-FM smears had higher sensitivity but lower specificity than single ZN smears. Using two LED-FM or two ZN smears per patient was 72.8% (385/529, 95% CI 68.8%–76.5%) and 65.8% (348/529, 95% CI 61.6%–69.8%) sensitive (p<0.001) and 90.9% (1,660/1,826, 95% CI 89.5%–92.2%) and 98% (1,790/1,826, 95% CI 97.3%–98.6%) specific (p<0.001). Using three LED-FM or three ZN smears per patient was 77% (408/529, 95% CI 73.3%–80.6%) and 70.5% (373/529, 95% CI 66.4%–74.4%, p<0.001) sensitive and 88.1% (95% CI 86.5%–89.6%) and 96.5% (95% CI 96.8%–98.2%, p<0.001) specific. The sensitivity/specificity of ZN smear microscopy and LED-FM did not vary between SMS and SSM. Conclusions LED-FM had higher sensitivity but, in this study, lower specificity than ZN smear microscopy for diagnosis of pulmonary TB. Performance was independent of the scheme used for collecting specimens. The introduction of LED-FM needs to be accompanied by appropriate training, quality management, and monitoring of performance in the field. Trial Registration Current Controlled Trials ISRCTN53339491 Please see later in the article for the Editors' Summary PMID:21765809

  7. Adenocarcinoma in situ of the cervix.

    PubMed

    Schoolland, Meike; Segal, Amanda; Allpress, Stephen; Miranda, Alina; Frost, Felicity A; Sterrett, Gregory F

    2002-12-25

    The current study examines 1) the sensitivity of detection and 2) sampling and screening/diagnostic error in the cytologic diagnosis of adenocarcinoma in situ (AIS) of the cervix. The data were taken from public and private sector screening laboratories reporting 25,000 and 80,000 smears, respectively, each year. The study group was comprised of women with a biopsy diagnosis of AIS or AIS combined with a high-grade squamous intraepithelial lesion (HSIL) who were accessioned by the Western Australian Cervical Cytology Registry (WACCR) between 1993-1998. Cervical smears reported by the Western Australia Centre for Pathology and Medical Research (PathCentre) or Western Diagnostic Pathology (WDP) in the 36 months before the index biopsy was obtained were retrieved. A true measure of the sensitivity of detection could not be determined because to the authors' knowledge the exact prevalence of disease is unknown at present. For the current study, sensitivity was defined as the percentage of smears reported as demonstrating a possible or definite high-grade epithelial abnormality (HGEA), either glandular or squamous. Sampling error was defined as the percentage of smears found to have no HGEA on review. Screening/diagnostic error was defined as the percentage of smears in which HGEA was not diagnosed initially but review demonstrated possible or definite HGEA. Sensitivity also was calculated for a randomly selected control group of biopsy proven cases of Grade 3 cervical intraepithelial neoplasia (CIN 3) accessioned at the WACCR in 1999. For biopsy findings of AIS alone, the diagnostic "sensitivity" of a single smear was 47.6% for the PathCentre and 54.3% for WDP. Nearly all the abnormalities were reported as glandular. The sampling and screening/diagnostic errors were 47.6% and 4.8%, respectively, for the PathCentre and 33.3% and 12.3%, respectively, for WDP. The results from the PathCentre were better for AIS plus HSIL than for AIS alone, but the results from WDP were similar for both groups. For the CIN 3 control cases, the "sensitivity" of a single smear was 42.5%. To the authors' knowledge epidemiologic studies published to date have not demonstrated a benefit from screening for precursors of cervical adenocarcinoma. However, in the study laboratories as in many others, reasonable expertise in diagnosing AIS has been acquired only within the last 10-15 years, which may be too short a period in which to demonstrate a significant effect. The results of the current study provide some encouraging baseline data regarding the sensitivity of the Papanicolaou smear in detecting AIS. Further improvements in sampling and cytodiagnosis may be possible. Copyright 2002 American Cancer Society.

  8. Implementation of the Thin Layer Agar Method for Diagnosis of Smear-Negative Pulmonary Tuberculosis in a Setting with a High Prevalence of Human Immunodeficiency Virus Infection in Homa Bay, Kenya▿ †

    PubMed Central

    Martin, Anandi; Munga Waweru, Peter; Babu Okatch, Fred; Amondi Ouma, Naureen; Bonte, Laurence; Varaine, Francis; Portaels, Françoise

    2009-01-01

    The objective of this study was to evaluate the performance of a low-cost method, the thin layer agar (TLA) method, for the diagnosis of smear-negative patients. This prospective study was performed in Homa Bay District Hospital in Kenya. Out of 1,584 smear-negative sputum samples, 212 (13.5%) were positive by culture in Löwenstein-Jensen medium (LJ) and 220 (14%) were positive by the TLA method. The sensitivities of LJ and TLA were 71% and 74%, respectively. TLA could become an affordable method for the diagnosis of smear-negative tuberculosis in resource-limited settings, with results available within 2 weeks. PMID:19494065

  9. In-house PCR with DNA extracted directly from positive slides to confirm or exclude the diagnosis of tuberculosis: focus on biosafety.

    PubMed

    de Almeida, Isabela Neves; Aleixo, Agdemir Valéria; Carvalho, Wânia da Silva; de Miranda, Silvana Spindola

    2015-01-01

    The possibility to obtain DNA from smears is a valuable alternative to remedy the lack of samples when they are totally used for bacilloscopy; this technique solves the biosafety problem related to a possible accident with the transportation of flasks containing potentially transmissible clinical samples. Hence, the purpose of this study was to utilize the insertion sequence IS6110 for amplification of DNA from a smear-positive sample for tuberculosis (TB) diagnosis. Among the 52 positive bacilloscopies, sensitivity, specificity, positive predictive value and negative predictive value were 52.3%, 100%, 100% and 89.7%, respectively whereas accuracy was 90.7%. The IS6110-based PCR for TB diagnosis developed in DNA extracted from a positive smear is a fast, simple, specific, and safe method. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Progression of abnormal MIB-1 staining patterns of reserve cells in cervical smears from women ultimately developing high grade squamous intraepithelial lesions.

    PubMed

    Siemens, Frederike C; van Haaften, Carolien; Kuijpers, Johan C; Helmerhorst, Theo J M; Boon, Mathilde E

    2006-01-01

    To assess, in a longitudinal study in women diagnosed with high grade squamous epithelial lesion (HSIL), the progression over time of proliferative activity in reserve cells using population screening cervical cytology specimens. Twenty consecutive, unselected patients with HSIL lesions were part of the national cervical screening program. From the archives, for each patient, the last prior normal population screening smear was included in the study. Concurrent sets of cervical smears from 80 age-matched women without pathology formed the controls. The original slides were stained using MIB-1 monoclonal antibody. The fraction of MIB-1-positive reserve cells was assessed using systematic random sampling and running progressive means assessment to ensure a sufficient sample size. The proliferation fraction in reserve cells of HSIL patients was significantly raised (mean, 65.0%; range, 53.5-94.1%; p < 0.01) as compared with that in concurrent controls (mean, 12.8%; range, 1.9-45.4%). Prior smears from HSIL patients, although without morphologic abnormalities, had abnormally high proliferation fractions (mean, 59.1%; range, 1.0-94.7%), significantly raised over those from concurrent controls (mean, 9.4%; range In population-based cervical smear screening, HSIL patients already have abnormally raised proliferation fractions of reserve cells, even without morphologic changes in squamous cells, 1-5 (mean, 3.6) years prior to diagnosis.

  11. Increasing Pap Smear Utilization Among Samoan Women: Results from a Community Based Participatory Randomized Trial

    PubMed Central

    Mishra, Shiraz I.; Luce, Pat H.; Baquet, Claudia R.

    2013-01-01

    Background We tested the effectiveness of a theory-guided, culturally tailored cervical cancer education program designed to increase Pap smear use among Samoan women residing in the U.S. Territory of American Samoa. Methods We used a two-group, pretest-posttest design. The sample comprised 398 Samoan women age 20 and older who we recruited from Samoan churches. Women in the intervention group received a culturally tailored cervical cancer education program in three weekly sessions. The primary outcome was self-reported receipt of a Pap smear. Results Overall, there was a significant intervention effect, with intervention compared with control group women twice (adjusted odds ratio = 2.0, 95% confidence interval = 1.3–3.2, p<.01) as likely to self-report Pap smear use at the posttest. Conclusions The findings support the efficacy of the multifaceted, theory-guided, culturally tailored community-based participatory cervical cancer education program for Samoan women in effecting positive changes in Pap smear use and cervical cancer related knowledge and attitudes. PMID:19711495

  12. Gardnerella infection as distinguished from cervical dysbacteriosis: the advantageous spin-off of cervical screening.

    PubMed

    Klomp, Johanna M; Ouwerkerk-Noordam, Elisabeth; Boon, Mathilde E; van Haaften, Maarten; Heintz, A Peter M

    2009-01-01

    To evaluate cytologic diagnoses of dysbacteriosis and Gardnerella infection and to obtain insight into the diagnostic problems of Gardnerella. One hundred randomly selected samples of each of 3 diagnostic series were rescreened by 2 pathologists, resulting in 2 rescreening diagnoses and a consensus diagnosis. A smear was considered unequivocal when the original O code and the O code of the consensus diagnoses were equal and discordant when the flora diagnoses of the 2 pathologists differed. Discordance was highest in the dysbacteriotic series (20%) and lowest in the healthy group (4%). Unequivocal diagnoses were established in 65% of the dysbacteriotic smears, 80% of the Gardnerella smears and 93% of the healthy smears. Misclassification of Gardnerella occurred in the presence of clusters of bacteria mixed with spermatozoa. Blue mountain cells in Gardnerella infection can be identified unequivocally in cervical smears. Because of the clinical importance of treating Gardnerella, such advantageous spin-offs of cervical screening should be exploited.

  13. Tensile behaviors of three-dimensionally free-formable titanium mesh plates for bone graft applications

    NASA Astrophysics Data System (ADS)

    He, Jianmei

    2017-11-01

    Present metal artificial bones for bone grafts have the problems like too heavy and excessive elastic modulus compared with natural bones. In this study, three-dimensionally (3D) free-formable titanium mesh plates for bone graft applications was introduced to improve these problems. Fundamental mesh shapes and patterns were designed under different base shapes and design parameters through three dimensional CAD tools from higher flexibility and strength points of view. Based on the designed mesh shape and patterns, sample specimens of titanium mesh plates with different base shapes and design variables were manufactured through laser processing. Tensile properties of the sample titanium mesh plates like volume density, tensile elastic modulus were experimentally and analytically evaluated. Experimental results showed that such titanium mesh plates had much higher flexibility and their mechanical properties could be controlled to close to the natural bones. More details on the mechanical properties of titanium mesh plates including compression, bending, torsion and durability will be carried out in future study.

  14. Self-Sampling for Human Papillomavirus Testing: Increased Cervical Cancer Screening Participation and Incorporation in International Screening Programs

    PubMed Central

    Gupta, Sarah; Palmer, Christina; Bik, Elisabeth M.; Cardenas, Juan P.; Nuñez, Harold; Kraal, Laurens; Bird, Sara W.; Bowers, Jennie; Smith, Alison; Walton, Nathaniel A.; Goddard, Audrey D.; Almonacid, Daniel E.; Zneimer, Susan; Richman, Jessica; Apte, Zachary S.

    2018-01-01

    In most industrialized countries, screening programs for cervical cancer have shifted from cytology (Pap smear or ThinPrep) alone on clinician-obtained samples to the addition of screening for human papillomavirus (HPV), its main causative agent. For HPV testing, self-sampling instead of clinician-sampling has proven to be equally accurate, in particular for assays that use nucleic acid amplification techniques. In addition, HPV testing of self-collected samples in combination with a follow-up Pap smear in case of a positive result is more effective in detecting precancerous lesions than a Pap smear alone. Self-sampling for HPV testing has already been adopted by some countries, while others have started trials to evaluate its incorporation into national cervical cancer screening programs. Self-sampling may result in more individuals willing to participate in cervical cancer screening, because it removes many of the barriers that prevent women, especially those in low socioeconomic and minority populations, from participating in regular screening programs. Several studies have shown that the majority of women who have been underscreened but who tested HPV-positive in a self-obtained sample will visit a clinic for follow-up diagnosis and management. In addition, a self-collected sample can also be used for vaginal microbiome analysis, which can provide additional information about HPV infection persistence as well as vaginal health in general. PMID:29686981

  15. Cervical cancer screening among Lebanese women.

    PubMed

    Bou-Orm, I R; Sakr, R E; Adib, S M

    2018-02-01

    Cervical cancer is a very common malignancy amongst women worldwide. Pap smear is an effective and inexpensive screening test in asymptomatic women. The aim of this paper was to assess the prevalence of Pap smear screening for cervical cancer among Lebanese women and to determine associated sociodemographic and psychosocial characteristics. This national survey included 2255 women, selected by multi-stage random cluster sampling across Lebanon. A questionnaire about practices and perceptions related to cervical cancer screening was developed based on the "Health Belief Model". The weighted national prevalence of "ever-use" of the Pap smear for screening purposes was 35%. Most important determinants of screening behavior were: residence within Greater Beirut, higher socio-economic status and educational attainment, marriage status, presence of a health coverage, awareness of Pap smear usefulness, knowing someone who had already done it, and a balance between perceived benefits and perceived barriers to Pap smear screening. Regular information campaigns regarding the availability and effectiveness of the test should be devised, targeting in priority the sexually vulnerable women in Lebanon. Moreover, healthcare providers should be encouraged to discuss with their patients the opportunity of obtaining a Pap smear. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Xpert MTB/RIF assay for diagnosis of pulmonary tuberculosis in sputum specimens in remote health care facility.

    PubMed

    Geleta, Dereje Assefa; Megerssa, Yoseph Cherinet; Gudeta, Adugna Negussie; Akalu, Gizachew Taddesse; Debele, Melaku Tesfaye; Tulu, Kassu Desta

    2015-10-19

    Xpert MTB/RIF assay is considered as a great advance over conventional smear and culture in the diagnosis of TB and MDR-TB by simultaneously detecting M.tuberculosis and rifampicin resistance bacilli. However, very little information regarding the performance characteristics of Xpert MTB/RIF assay is available in Ethiopia. Therefore, the purpose of this study was to evaluate the performance of Xpert MTB/RIF assay compared to conventional sputum smear and culture methods for the diagnosis of pulmonary tuberculosis in remote health care facility. A paired expectorated sputum samples were obtained from 227 consecutively recruited patients with signs and symptoms suggestive of tuberculosis at Karamara hospital during December 2013 to May 2014. One of the sputum specimen was tested directly by Ziehl-Neelsen staining and Xpert MTB/RIF assay without NALC-NaOH decontamination. The other of pair of sputa specimen was cultured for isolation of TB bacilli by conventional methods. Diagnostic performance of Xpert MTB/RIF assay and AFB smear microscopy were calculated against culture as the gold standard. Overall 25.5% (58/227) samples were positive for Mycobacterium tuberculosis complex (MTBC) by MGIT and/or LJ media of which 36.2% (21/58) and 65.5% (35/58) were positive by AFB smear microscopy and Xpert MTB/RIF respectively. The sensitivity, specificity, as well as the positive and negative predictive value of Xpert MTB/RIF assay were 65.5% (95% CI: 53.3-77.7%), 96.3% (95% CI: 93.4-99.2%), 86.4% (95% CI: 76.2-96.5%), and 88.6% (95% CI: 83.9-93.3%) respectively. Eighteen of 58 (31%) cases that were smear microscopy negative, were positive by Xpert MTB/RIF assay. Although Xpert MTB/RIF assay demonstrated high sensitivity in detecting MTBC in sputum specimens compared with conventional AFB smear microscopy, it demonstrated suboptimal sensitivity in smear negative patients compared to conventional culture.

  17. A comparison of digitized frozen section and smear preparations for intraoperative neurotelepathology.

    PubMed

    Gould, Peter V; Saikali, Stephan

    2012-01-01

    Intraoperative consultations in neuropathology are often assessed by smear preparations rather than by frozen sections. Both techniques are standard practice for light microscopic examination on site, but there is little data comparing these techniques in a telepathology setting. Thirty cases of brain tumours submitted for intraoperative consultation at our institution between July and December 2010 were identified in which both frozen section and tissue smear preparations were available for digitization at 20× magnification. Slides were digitized using a Hamamatsu Nanozoomer 2.0 HT whole slide scanner, and resulting digital images were visualized at 1680 × 1050 pixel resolution with NDP. view software. The original intraoperative diagnosis was concordant with the sign out diagnosis in 29/30 cases; one tumeur was initially interpreted as a high grade glioma but proved to be a lymphoma at sign out. Digitized frozen section slides were sufficient for diagnosis at 10× magnification in 27/30 cases. Digitized tissue smears were sufficient for diagnosis at 10× magnification in 28/30 cases. In two cases tumour was present on the tissue smear but not the frozen section (one case of recurrent astrocytoma, one case of meningeal carcinomatosis). In one case of lymphoma, tumour was present on frozen section only. These discrepancies were attributed to tissue sampling rather than image quality. Examination of digitized slides at higher magnfication (20×) permitted confirmation of mitoses and Rosenthal fibers on tissue smear preparations, but did not change the primary diagnosis. Intra-slide variations in tissue thickness on smear preparations led to variable loss of focus in digitized images, but did not affect image quality in thinner areas of the smear or impede diagnosis. Digitized tissue smears are suitable for intraoperative neurotelepathology and provide comparable information to digitized frozen sections at medium power magnification.

  18. Influence of Smear Layer on the Antimicrobial Activity of a Sodium Hypochlorite/Etidronic Acid Irrigating Solution in Infected Dentin.

    PubMed

    Morago, Ana; Ordinola-Zapata, Ronald; Ferrer-Luque, Carmen María; Baca, Pilar; Ruiz-Linares, Matilde; Arias-Moliz, María Teresa

    2016-11-01

    The aim of this study was to evaluate the influence of the smear layer on the antimicrobial activity of a 2.5% sodium hypochlorite (NaOCl)/9% etidronic acid (HEBP) irrigating solution against bacteria growing inside dentin tubules. Dentin tubules were infected with Enterococcus faecalis by centrifugation. After 5 days of incubation, the smear layer had formed in half of the samples, which were then treated with 2.5% NaOCl either alone or combined with 9% HEBP for 3 minutes. The percentage of dead cells in infected dentinal tubules was measured using confocal laser scanning microscopy and the live/dead technique. The smear layer on the surface of the root canal wall was also observed by scanning electron microscopy. Results of the percentage of dead cells were compared using parametric tests after subjecting data to the normalized Anscombe transformation. The level of significance was P < .05. In the absence of the smear layer, 2.5% NaOCl alone and combined with 9% HEBP showed high antimicrobial activity without significant differences between the 2. The smear layer reduced the antimicrobial activity of 2.5% NaOCl significantly, whereas the solution with HEBP was not affected. No dentin tubules free of the smear layer were obtained in the 2.5% NaOCl group. In the case of 2.5% NaOCl/9% HEBP, 95.40% ± 3.63% of dentin tubules were cleaned. The presence of the smear layer reduced the antimicrobial activity of 2.5% NaOCl. The combination of 2.5% NaOCl/9% HEBP exerted antimicrobial activity that was not reduced by the smear layer. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Confusion about Pap smears: lack of knowledge among high-risk women.

    PubMed

    Daley, Ellen; Perrin, Kay; Vamos, Cheryl; Hernandez, Natalie; Anstey, Erica; Baker, Elizabeth; Kolar, Stephanie; Ebbert, Judith

    2013-01-01

    The impact of the Papanicolaou (Pap) smear on the prevention of cervical cancer is one of the greatest public health success stories. However, it is not clear if women understand the purpose of the Pap smear despite recent advancements and national attention over cervical cancer prevention. The purpose of this study was to examine Pap smear knowledge among three high-risk populations at different points in time. Women from three separate human papillomavirus (HPV) psychosocial studies completed surveys assessing Pap smear knowledge: (1) HPV-positive women (prevaccine population in 2005-2006, n=154, mean age 23.5), (2) college women (postvaccine population in 2008, n=276, mean age 18.9), and (3) minority college women (postvaccine population in 2011, n=711, mean age 23.3). Frequencies and logistic regression were employed to examine associations between demographic factors and accurate knowledge of Pap smear testing within each study. Approximately one quarter of participants across all three samples did not know that the Pap smear is a test for cervical cancer. Participants also incorrectly believed that the Pap smear tests for HPV (82%-91%), vaginal infections (76%-92%), yeast infections (65%-86%), gonorrhea (55%-81%), herpes (53%-80%), HIV/AIDS (22%-59%), and pregnancy (17%-38%). Among all three studies, older age was the only factor significant with higher Pap knowledge. Higher HPV knowledge scores were significantly associated with higher Pap knowledge in studies 2 and 3 only. Knowledge about the purpose of the Pap smear remains low. Findings underscore the significant need for clear and consistent messages among high-risk women regarding the prevention of cervical cancer and other reproductive health conditions.

  20. Efficacy of Er,Cr:YSGG Laser in Removing Smear Layer and Debris with Two Different Output Powers

    PubMed Central

    Bolhari, Behnam; Ehsani, Sara; Etemadi, Ardavan; Shafaq, Mohammad

    2014-01-01

    Abstract Objective: The purpose of this study was to evaluate the effectiveness of the erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser in removing debris and the smear layer using two different output powers on the apical, middle, and coronal segments of root canal walls. Background data: Previous literature has failed to evaluate the exclusive effect of Er,Cr:YSGG laser on the quality of smear layer and debris removal in all three segments of the root canal space. Methods: Sixty extracted teeth were included in the study. After instrumentation, samples were divided into three experimental groups and one positive control group with no further treatment. In group 1, a final irrigation was performed using ethylenediaminetetraacetic acid (EDTA) and sodium hypochlorite (NaOCl), sequentially. In group 2, the samples were treated with a 2.78 μm Er,Cr:YSGG laser with an output power of 1.5 W. The same laser was used in group 3, but with an output power of 2.5 W. Scanning electron microscope (SEM) images from the coronal, middle, and apical thirds of the roots were prepared and evaluated for both smear layer and debris removal by three blinded observers. Results: The results showed no differences between groups 1 and 2 regarding the quality of smear layer removal in all areas. However, the 2.5 W laser failed to remove the smear layer effectively. Regarding debris removal, the EDTA and NaOCl irrigation showed significantly better outcomes (adjusted p<0.05) in all areas. Conclusions: This study raises questions about the overall cleaning abilities of Er,Cr:YSGG lasers. PMID:25198390

  1. Efficacy of Er,Cr:YSGG laser in removing smear layer and debris with two different output powers.

    PubMed

    Bolhari, Behnam; Ehsani, Sara; Etemadi, Ardavan; Shafaq, Mohammad; Nosrat, Ali

    2014-10-01

    The purpose of this study was to evaluate the effectiveness of the erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser in removing debris and the smear layer using two different output powers on the apical, middle, and coronal segments of root canal walls. Previous literature has failed to evaluate the exclusive effect of Er,Cr:YSGG laser on the quality of smear layer and debris removal in all three segments of the root canal space. Sixty extracted teeth were included in the study. After instrumentation, samples were divided into three experimental groups and one positive control group with no further treatment. In group 1, a final irrigation was performed using ethylenediaminetetraacetic acid (EDTA) and sodium hypochlorite (NaOCl), sequentially. In group 2, the samples were treated with a 2.78 μm Er,Cr:YSGG laser with an output power of 1.5 W. The same laser was used in group 3, but with an output power of 2.5 W. Scanning electron microscope (SEM) images from the coronal, middle, and apical thirds of the roots were prepared and evaluated for both smear layer and debris removal by three blinded observers. The results showed no differences between groups 1 and 2 regarding the quality of smear layer removal in all areas. However, the 2.5 W laser failed to remove the smear layer effectively. Regarding debris removal, the EDTA and NaOCl irrigation showed significantly better outcomes (adjusted p<0.05) in all areas. This study raises questions about the overall cleaning abilities of Er,Cr:YSGG lasers.

  2. Rate of Opportunistic Pap Smear Screening and Patterns of Epithelial Cell Abnormalities in Pap Smears in Ajman, United Arab Emirates

    PubMed Central

    Al Eyd, Ghaith J.; Shaik, Rizwana B.

    2012-01-01

    Objectives: The aim of this study was to estimate the proportion of women undergoing Papanicolaou (Pap) smear examinations, and the frequency of epithelial cell abnormalities in a teaching hospital in one emirate of the United Arab Emirates (UAE) during a three-year period. Methods: A retrospective study of 602 patient records from July 2007 to July 2010 was done in a teaching hospital in Ajman, UAE. The variables studied were age, ethnicity, menopausal status, and abnormalities in the Pap smear. Data were analysed using the Statistical Package for the Social Sciences and presented mainly as percentages; to assess associations, the chi-square test was used. Results: The total number of outpatients who attended the Obstetrics & Gynaecology Department from July 2007 to July 2010 was 150,111 patients, of which 602 (0.4% of the total) had a Pap smear test. The sample was 50.1% Arabs and 49.9% other nationalities. While 73% of the outpatients had specific complaints, 27% came for a routine screening. Epithelial cell abnormalities were seen in 3.3% of the sample, with atypical squamous cells of undetermined significance (ASCUS) found in 1.8%, low-grade squamous intraepithelial lesions (LSILs) found in 1.2%, and high-grade squamous intraepithelial lesions (HSILs) found in 0.3%. There were no cases of squamous cell carcinoma. Conclusion: Voluntary routine Pap smear screening was remarkably low in the study group. ASCUS was the most common epithelial cell abnormality. Community health education and opportunistic screening for cervical cancer are recommended for both national and expatriate women in the region. PMID:23275844

  3. [Scanning electron microscopy investigation of canal cleaning after canal preparation with nickel titanium files].

    PubMed

    Brkanić, Tatjana; Ivana, Stojsin; Vukoje, Karolina; Zivković, Slavoljub

    2010-01-01

    Root canal preparation is the most important phase of endodontic procedure and it consists of adequate canal space cleaning and shaping. In recent years, rotary instruments and techniques have gained importance because of the great efficacy, speed and safety of the preparation procedure. The aim of this research was to investigate the influence of different NiTi files on the canal wall cleaning quality, residual dentine debris and smear layer. The research was conducted on extracted human teeth in vitro conditions. Teeth were divided in 7 main groups depending on the kind of instruments used for root canal preparation: ProTaper, GT, ProFile, K-3, FlexMaster, hand ProTaper and hand GT. Root canal preparation was accomplished by crown-down technique. Prepared samples were assessed on scanning electron microscopy JEOL, JSM-6460 LV. The evaluation of dentine debris was done with 500x magnification, and the evaluation of smear layer with 1,000 times magnification. Quantitive assessment of dentine debris and smear layer was done according to the criteria of Hulsmann. The least amount of debris and smear layer has been found in canals shaped with ProFile instruments, and the largest amount in canals shaped with FlexMaster instruments. Canal cleaning efficacy of hand GTand ProTaperfiles has been similar to cleaning efficacy of rotary NiTi files. Statistic analysis has shown a significant difference in amount of dentine debris and smear layer on the canal walls between sample groups. shaped with different instruments. Completely clean canals have not been found in any tested group of instruments. The largest amount of debris and smear layer has been found in the apical third of all canals. The design and the type of endodontic instruments influence the efficacy of the canal cleaning.

  4. Simplified Pan-species Real-time PCR-based Detection of Plasmodium Spp. in Blood Smear.

    PubMed

    Hassanpour, Gholamreza; Mirhendi, Hossein; Mohebali, Mehdi; Raeisi, Ahmad; Zeraati, Hojjat; Keshavarz, Hossein

    2016-01-01

    We aimed to quicken and simplify the detection of Plasmodium in blood samples by developing and testing a pan- Plasmodium real-time PCR for accurate screening of individuals suspected of malaria. A single primer/probe set for pan-species Plasmodium -specific real time PCR targeting a conserved region of the small subunit 18S ribosomal DNA was designed and evaluated for rapid diagnosis and screening of malaria infections using dried blood smears. FTA cards were used for rapid and simple DNA extraction. The primers and probes showed a positive response with the DNA extracted from bloods infected with P. falciparum and P. vivax but not with DNA extracted from various smears from uninfected blood samples. Seven positive cases positive by both microscopy and nested PCR were found among 280 blood samples taken from in South and Southeast Iran. Five samples were identified as positive for P. vivax and two as positive for P. falciparum . All positive samples were positive by real-time PCR. Furthermore, all 38-blood samples positive by microscopy were positive by real-time PCR. No microscopy-negative samples were positive by real-time PCR. By using a simple FTA card for DNA extraction and by application of the real-time PCR developed in this study, sensitivity similar to nested-PCR and microscopy was achieved. This format simplifies the detection of Plasmodium in large numbers of samples.

  5. A FORTRAN program for calculating three dimensional, inviscid and rotational flows with shock waves in axial compressor blade rows: User's manual

    NASA Technical Reports Server (NTRS)

    Thompkins, W. T., Jr.

    1982-01-01

    A FORTRAN-IV computer program was developed for the calculation of the inviscid transonic/supersonic flow field in a fully three dimensional blade passage of an axial compressor rotor or stator. Rotors may have dampers (part span shrouds). MacCormack's explicit time marching method is used to solve the unsteady Euler equations on a finite difference mesh. This technique captures shocks and smears them over several grid points. Input quantities are blade row geometry, operating conditions and thermodynamic quanities. Output quantities are three velocity components, density and internal energy at each mesh point. Other flow quanities are calculated from these variables. A short graphics package is included with the code, and may be used to display the finite difference grid, blade geometry and static pressure contour plots on blade to blade calculation surfaces or blade suction and pressure surfaces. The flow in a low aspect ratio transonic compressor was analyzed and compared with high response total pressure probe measurements and gas fluorescence static density measurements made in the MIT blowdown wind tunnel. These comparisons show that the computed flow fields accurately model the measured shock wave locations and overall aerodynamic performance.

  6. Direct Detection of Rifampin and Isoniazid Resistance in Sputum Samples from Tuberculosis Patients by High-Resolution Melt Curve Analysis

    PubMed Central

    Anthwal, Divya; Gupta, Rakesh Kumar; Bhalla, Manpreet; Bhatnagar, Shinjini

    2017-01-01

    ABSTRACT Drug-resistant tuberculosis (TB) is a major threat to TB control worldwide. Globally, only 40% of the 340,000 notified TB patients estimated to have multidrug-resistant-TB (MDR-TB) were detected in 2015. This study was carried out to evaluate the utility of high-resolution melt curve analysis (HRM) for the rapid and direct detection of MDR-TB in Mycobacterium tuberculosis in sputum samples. A reference plasmid library was first generated of the most frequently observed mutations in the resistance-determining regions of rpoB, katG, and an inhA promoter and used as positive controls in HRM. The assay was first validated in 25 MDR M. tuberculosis clinical isolates. The assay was evaluated on DNA isolated from 99 M. tuberculosis culture-positive sputum samples that included 84 smear-negative sputum samples, using DNA sequencing as gold standard. Mutants were discriminated from the wild type by comparing melting-curve patterns with those of control plasmids using HRM software. Rifampin (RIF) and isoniazid (INH) monoresistance were detected in 11 and 21 specimens, respectively, by HRM. Six samples were classified as MDR-TB by sequencing, one of which was missed by HRM. The HRM-RIF, INH-katG, and INH-inhA assays had 89% (95% confidence interval [CI], 52, 100%), 85% (95% CI, 62, 97%), and 100% (95% CI, 74, 100%) sensitivity, respectively, in smear-negative samples, while all assays had 100% sensitivity in smear-positive samples. All assays had 100% specificity. Concordance of 97% to 100% (κ value, 0.9 to 1) was noted between sequencing and HRM. Heteroresistance was observed in 5 of 99 samples by sequencing. In conclusion, the HRM assay was a cost-effective (Indian rupee [INR]400/US$6), rapid, and closed-tube method for the direct detection of MDR-TB in sputum, especially for direct smear-negative cases. PMID:28330890

  7. Anisotropic evaluation of synthetic surgical meshes.

    PubMed

    Saberski, E R; Orenstein, S B; Novitsky, Y W

    2011-02-01

    The material properties of meshes used in hernia repair contribute to the overall mechanical behavior of the repair. The anisotropic potential of synthetic meshes, representing a difference in material properties (e.g., elasticity) in different material axes, is not well defined to date. Haphazard orientation of anisotropic mesh material can contribute to inconsistent surgical outcomes. We aimed to characterize and compare anisotropic properties of commonly used synthetic meshes. Six different polypropylene (Trelex(®), ProLite™, Ultrapro™), polyester (Parietex™), and PTFE-based (Dualmesh(®), Infinit) synthetic meshes were selected. Longitudinal and transverse axes were defined for each mesh, and samples were cut in each axis orientation. Samples underwent uniaxial tensile testing, from which the elastic modulus (E) in each axis was determined. The degree of anisotropy (λ) was calculated as a logarithmic expression of the ratio between the elastic modulus in each axis. Five of six meshes displayed significant anisotropic behavior. Ultrapro™ and Infinit exhibited approximately 12- and 20-fold differences between perpendicular axes, respectively. Trelex(®), ProLite™, and Parietex™ were 2.3-2.4 times. Dualmesh(®) was the least anisotropic mesh, without marked difference between the axes. Anisotropy of synthetic meshes has been underappreciated. In this study, we found striking differences between elastic properties of perpendicular axes for most commonly used synthetic meshes. Indiscriminate orientation of anisotropic mesh may adversely affect hernia repairs. Proper labeling of all implants by manufacturers should be mandatory. Understanding the specific anisotropic behavior of synthetic meshes should allow surgeons to employ rational implant orientation to maximize outcomes of hernia repair.

  8. Attitudes and factors affecting acceptability of self-administered cervicovaginal sampling for human papillomavirus (HPV) genotyping as an alternative to Pap testing among multiethnic Malaysian women

    PubMed Central

    Ma'som, Mahirah; Bhoo-Pathy, Nirmala; Nasir, Nazrila Hairizan; Bellinson, Jerome; Subramaniam, Shridevi; Ma, Yuntong; Yap, Siew-Hwei; Goh, Pik-Pin; Gravitt, Patti; Woo, Yin Ling

    2016-01-01

    Objective The objective of this study was to determine the attitudes and acceptability of self-administered cervicovaginal sampling compared with conventional physician-acquired Papanicolaou (Pap) smear among multiethnic Malaysian women. Method A cross-sectional study was carried out via interviewer-administered surveys from August 2013 through August 2015 at five government-run, urban health clinics in the state of Selangor. Subjects were participants from an ongoing community-based human papillomavirus (HPV) prevalence study who answered a standard questionnaire before and after self-sampling. The cervicovaginal self-sampling for HPV genotyping was performed using a simple brush (‘Just for Me’; Preventive Oncology International, Hong Kong). Detailed data on sociodemographics, previous Pap smear experience, and attitudes towards self-administered cervicovaginal sampling were collected and analysed. Acceptability was inferred using a five-item Likert scale that included six different subjective descriptives: experience, difficulty, convenience, embarrassment, discomfort or pain, and confidence in collecting one's own sample. Results Of the 839 participants, 47.9% were Malays, followed by 30.8% Indians, 18.8% Chinese and 2.5% from other ethnicities. The median age of the participants was 38 years (IQR 30–48). Some 68.2% of participants indicated a preference for self-sampling over the Pap test, with 95% indicating willingness to follow-up a positive result at the hospital. Age, ethnicity and previous Pap test experience were significant independent factors associated with preference for self-sampling. The older the individual, the less likely they were to prefer self-sampling (adjusted OR 0.94, 95% CI 0.90 to 0.98). The Chinese were less likely to prefer self-sampling (72.6%) than the Malays (85.1%) (adjusted OR 0.57, 95% CI 0.33 to 0.98, p=0.004). Participants who had never undergone a Pap smear were also more likely to prefer self-sampling (88.5%) than women who had undergone a previous Pap (80.9%) (adjusted OR 0.06, 95% CI 0.35 to 0.87). Conclusions Overall, urban Malaysian women from multiethnic backgrounds found self-sampling to be an acceptable alternative to Pap smear. PMID:27491667

  9. Smear-positive pulmonary tuberculosis and AFB examination practices according to the standard checklist of WHO's tuberculosis laboratory assessment tool in three governmental hospitals, Eastern Ethiopia.

    PubMed

    Mekonnen, Abiyu

    2014-05-13

    Using the Directly Observed Treatment-Short course (DOTS) program the World Health Organization's global target was to detect 70% of new sputum-smear positive PTB cases. Smear positive PTB cases are more infectious than the smear negative cases. The TB case detection rate remains very low in Ethiopia, but there are increases in smear-negative PTB diagnosis which could be attributed to several factors including poor quality of sputum smear-microscopy. A five years retrospective record review of data between September, 2007 and August, 2012 and an in-depth assessment of AFB staining practices of sputum smear using a standard checklist were made. The proportion of smear positive cases relative to overall Acid Fast Bacilli (AFB) screened was determined over a five year period to indicate the overall prevalence and the trend. Odds ratio with 95 percent confidence interval was calculated for categorical variables using multivariate Logistic Regression model to assess the strength of association. A total of 1266 individuals' data were reviewed. The majority of the study participants were male, 704 (55.6%), and rural residents, 690 (54.5%). The overall prevalence rate of smear positive PTB was 21.6%. Age categories between 15-24 and 25-34 years were independent predictors of smear positive PTB with adjusted odds ratio of 2.246 [95% CI (1.098-4.597)] and 2.267 [95% CI (1.107-4.642)], respectively. More males were affected by PTB than females with an adjusted odds ratio of 1.426 [95% CI (1.083-1.879)]. An in-depth interview with the respective laboratory chiefs showed that quality control measures for sputum smear microscopy were used at different levels of the testing activities; however, equipment function verification as a quality control measure was not accomplished regularly in all of the study hospital laboratories. The smear positive PTB case detection rate indicated in this study is significantly lower than the countries which met the 70% target of the World Health Organization. Lack of feedback mechanisms in the External Quality Assurance schemes of sputum smear microscopy render the opportunity for improvement difficult; Serial sputum examination showed a considerable rate of positivity in the second sputum sample when compared with the others.

  10. Detection of salts in soil using transversely excited atmospheric (TEA) carbon dioxide (CO2) laser-induced breakdown spectroscopy (LIBS) by the aid of a metal mesh

    NASA Astrophysics Data System (ADS)

    Idris, N.; Ramli, M.; Khumaeni, A.; Kurihara, K.

    2018-04-01

    In this work, a nickel metal mesh was used to allow a direct detection of salt in soil sample by LIBS utilizing unique characteristics of a TEA CO2. The metal mesh is placed in the front of the soil sample to prevent the soil sample from blowing off upon focusing the high pulsed laser beam irradiation. LIBS apparatus used in this work is a TEA CO2 laser operated at wavelength of 10.6 μm with pulse energy and duration of 3J and 200 ns, respectively. The laser beam was focused using a ZnSe lens (f = 200 mm) onto soil sample after passing through the metal mesh. The emission spectrum from the induced plasma was detected using an optical multichannel analyzer (OMA) system consisting of a 0.32-m-focal length spectrograph with a grating of 1200 graves/mm and a 1024-channel photodiode detector array with a micro-channel plate intensifier. The soil sample used is a standard soil and ordinary soil containing several salts such as Ca, Mg at high concentration. The LIBS experiment was carried out at high pressure surrounding gas of 1 atmosphere. It was observed that by the aid of the metal mesh, strong breakdown gas plasma can be produced just after TEA CO2 laser irradiation on soil sample without significant sample blowing off. It was found that emission lines from salts, Ca (Ca II 393. 3 nm, Ca II 396.3 nm, Ca I 422.5 nm), and also other salts including Mg and Na can clearly be detected with strong emission intensity and narrow spectral width. This result implies that a TEA CO2 LIBS assisted by the metal mesh (metal mesh method) can be used for direct analysis several salts such as Ca, Mg, and Na in soil sample.

  11. [The participation of vaginal bacteria in Phodopus campbelli in the chemical communication between male and female].

    PubMed

    Sokolov, V E; Ushakova, N A; Surov, A V; Telitsyna, A Iu

    1994-01-01

    Phodopus campbelli commonly occurs in dry steppe and semidesert zone of south Siberia, Mongolia and China. Using radiotelemetry we found that a male has to cover about 2 km from his burrow to encounter a receptive female. Female in estrus marks a small area around its burrow by vaginal smear. Experiments were carried out in laboratory to discover the nature of this strong signal. In a "open field" area four boxes within stimuli we recorded the time complemented spent by males near boxes to study the attractive effect of intact receptive female, germ culture of vaginal smear and artificial mixed culture of bacteria which were found in the vaginal smear of Ph. campbelli receptive female. Males (n = 15) spent significantly more time near the boxes with female in estrus or day before estrus as compared with two other days of cycle. Germ culture from vaginal smear sampled on the estrus day was more attractive to males on 6th day than on the 2, -3, -5, -7, -8--or 9th days of cultivation, pure culture or germ culture sampled on anestrus. Mixed culture, which simulated the proportion of predominant bacteria in the estrus vaginal smear, was significantly more attractive for males on the 3rd day of cultivation. Thus sexual attractant of Ph. campbelli could be produced by some bacteria located in the vagina in estrus and it takes a couple of days of cultivation for maximum attractive effect.

  12. Updates to Simulation of a Single-Element Lean-Direct Injection Combustor Using Arbitary Polyhedral Meshes

    NASA Technical Reports Server (NTRS)

    Wey, Thomas; Liu, Nan-Suey

    2015-01-01

    This paper summarizes the procedures of (1) generating control volumes anchored at the nodes of a mesh; and (2) generating staggered control volumes via mesh reconstructions, in terms of either mesh realignment or mesh refinement, as well as presents sample results from their applications to the numerical solution of a single-element LDI combustor using a releasable edition of the National Combustion Code (NCC).

  13. Optimization of liquid scintillation measurements applied to smears and aqueous samples collected in industrial environments

    NASA Astrophysics Data System (ADS)

    Chapon, Arnaud; Pigrée, Gilbert; Putmans, Valérie; Rogel, Gwendal

    Search for low-energy β contaminations in industrial environments requires using Liquid Scintillation Counting. This indirect measurement method supposes a fine control from sampling to measurement itself. Thus, in this paper, we focus on the definition of a measurement method, as generic as possible, for both smears and aqueous samples' characterization. That includes choice of consumables, sampling methods, optimization of counting parameters and definition of energy windows, using the maximization of a Figure of Merit. Detection limits are then calculated considering these optimized parameters. For this purpose, we used PerkinElmer Tri-Carb counters. Nevertheless, except those relative to some parameters specific to PerkinElmer, most of the results presented here can be extended to other counters.

  14. [Automated RNA amplification for the rapid identification of Mycobacterium tuberculosis complex in respiratory specimens].

    PubMed

    Drouillon, V; Houriez, F; Buze, M; Lagrange, P; Herrmann, J-L

    2006-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis complex (MTB) directly on clinical respiratory specimens is essential for a correct management of patients suspected of tuberculosis. For this purpose PCR-based kits are available to detect MTB in respiratory specimen but most of them need at least 4 hours to be completed. New methods, based on TRC method (TRC: Transcription Reverse transcription Concerted--TRCRapid M. Tuberculosis--Tosoh Bioscience, Tokyo, Japon) and dedicated monitor have been developed. A new kit (TRC Rapid M. tuberculosis and Real-time monitor TRCRapid-160, Tosoh Corporation, Japan) enabling one step amplification and real-time detection of MTB 16S rRNA by a combination of intercalative dye oxazole yellow-linked DNA probe and isothermal RNA amplification directly on respiratory specimens has been tested in our laboratory. 319 respiratory specimens were tested in this preliminary study and results were compared to smear and culture. Fourteen had a positive culture for MTB. Among theses samples, smear was positive in 11 cases (78.6%) and TRC process was positive in 8 cases (57.1%). Overall sensitivity of TRC compared to smear positive samples is 73%. Theses first results demonstrated that a rapid identification of MTB was possible (less than 2 processing hours for 14 specimens and about 1 hour for 1 specimen) in most cases of smear positive samples using ready to use reagents for real time detection of MTB rRNA in clinical samples. New pretreatment and extraction reagents kits to increase the stability of the sputum RNA and the extraction efficiency are now tested in our laboratory.

  15. Trypanosoma cruzi infection of squirrel monkeys: comparison of blood smear examination, commercial enzyme-linked immunosorbent assay, and polymerase chain reaction analysis as screening tests for evaluation of monkey-related injuries.

    PubMed

    Ndao, M; Kelly, N; Normandin, D; Maclean, J D; Whiteman, A; Kokoskin, E; Arevalo, I; Ward, B J

    2000-12-01

    Wild-caught New World monkeys (NWM) from Central or South America are often infected with Trypanosoma species, including T. cruzi. In humans, T. cruzi causes Chagas' disease. Even in closed monkey colonies, T. cruzi can be propagated by blood-to-blood exposure, sexual activity, and transplacental transmission. Animal handlers and laboratory staff who deal with blood and tissues from infected NWM are at riskfor acquiring Chagas' disease via accidental exposure. We screened 162 blood samples from wild-caught Saimiri sp. monkeys for Trypanosoma species infections by use of blood smear examination, ELISA, and polymerase chain reaction (PCR) analysis. Blood samples from 19 employees with recent history of monkey-associated injuries also were tested. Six percent (10/162) of the monkey samples were T. cruzi positive on the basis of blood smear examination results, 10.4% (17/162) were positive by ELISA results, and 26.5% (43/162) were positive by PCR results. Other organisms identified by PCR analysis included T. rangeli in two animals, Plasmodium spp. in two animals (P. malariae confirmed by PCR results) and microfilariae in one animal (morphologically, Mansonella perstans). Evidence of trypanosome infection was not found in the 19 employee samples on the basis of results of any of the three aforementioned tests. Close attention must be paid to worker safety where wild-caught NWM are used. The PCR analysis has a clear advantage over conventional techniques (ELISA, blood smear) for screening NWM for trypanosome infections during quarantine and after employee injury.

  16. [Automated procedures for microscopic analyses of blood smears: medical testing a MECOS-Ts2 complex].

    PubMed

    Pliasunova, S A; Balugian, R Sh; Khmel'nitskiĭ, K E; Medovyĭ, V S; Parpara, A A; Piatnitskiĭ, A M; Sokolinskiĭ, B Z; Dem'ianov, V L; Nikolaenko, D S

    2006-10-01

    The paper presents the results of medical tests of a group of computer-aided procedures for microscopic analysis by means of a MECOS-Ts2 complex (ZAO "MECOS", Russia), which have been conducted at the Republican Children's Clinical Hospital, the Research Institute of Emergency Pediatric Surgery and Traumatology, and Moscow City Clinical Hospital No. 23. Computer-aided procedures for calculating the differential count and for analyzing the morphology of red blood cells were tested on blood smears from a total of 443 patients and donors, computer-aided calculation of the count of reticulocytes was tested on 318 smears. The tests were carried out under the US standard NCCLS-H20A. Manual microscopy (443 smears) and flow blood analysis on a Coulter GEN*S (125 smears) were used as reference methods. The quality of collection of samples and laboriousness were additionally assessed. The certified MECOS-Ts2 subsystems were additionally used as reference tools. The tests indicated the advantage of computer-aided MECOS-Tsl2 complex microscopy over manual microscopy.

  17. Molecular characterization of Hepatozoon canis in dogs from Colombia.

    PubMed

    Vargas-Hernandez, Giovanni; André, Marcos R; Munhoz, Thiago D; Faria, Joice M L; Machado, Rosangela Z; Tinucci-Costa, Mirela

    2012-01-01

    Hepatozoonosis is a tick-borne disease whose transmission to dogs occurs by ingestion of oocysts infected ticks or feeding on preys infested by infected ticks. Until now, there is no previous report of molecular characterization of Hepatozoon sp. in dogs from Colombia. EDTA blood samples were collected from 91 dogs from central-western region of Colombia (Bogotá, Bucaramanga, and Villavicencio cities) and submitted to 18S rRNA Hepatozoon sp. PCR and blood smears confection. Phylogenetic analysis was used to access the identity of Hepatozoon species found in sampled dogs. From 91 sampled dogs, 29 (31.8%) were positive to Hepatozoon sp. (25 dogs were only positive in PCR, 1 was positive only in blood smears, and 3 were positive in both blood smears and PCR). After sequencing, the found Hepatozoon sp. DNA showed 100% of identity with Hepatozoon canis DNA isolates. The phylogenetic tree supported the identity of the found Hepatozoon sp. DNA, showing that the isolates from Colombia were placed in the same clade than other H. canis isolates from Venezuela, Spain, and Taiwan. This is the first molecular detection of H. canis in dogs from Colombia.

  18. The utilization and barriers of Pap smear among women with visual impairment.

    PubMed

    Fang, Wen-Hui; Yen, Chia-Feng; Hu, Jung; Lin, Jin-Ding; Loh, Ching-Hui

    2016-04-12

    Many evidences illustrate that the Pap smear screening successfully reduces if the cervical cancer could be detected and treated sufficiently early. People with disability were higher comorbidity prevalence, and less likely to use preventive health care and health promotion activities. There were also to demonstrate that people with visual impairment has less access to appropriate healthcare services and is less likely to receive screening examinations. In Taiwan, there was no study to explore utilization of Pap smear, associated factors and use barriers about Pap smear screening test among women with visual impairment. The purpose is to explore the utilization and barriers of using Pap smear for women with visual impairment in Taiwan. To identify the barriers of women with visual from process of receiving Pap smear screening test. The cross-sectional study was conducted and the totally 316 participators were selected by stratified proportional and random sampling from 15 to 64 year old women with visual impairment who lived in Taipei County during December 2009 to January 2010. The data was been collected by phone interview and the interviewers were well trained before interview. The mean age was 47.1 years old and the highest percentage of disabled severity was mile (40.2 %). Totally, 66.5 % of participators were ever using Pap smear and 38.9 % used it during pass 1 year. Their first time to accept Pap smear was 38.8 year old. There was near 50 % of them not to be explained by professionals before accepting the Pap smear. For non-using cases, the top two percentage of barriers were "feel still younger" (22.3 %), the second was "there's no sexual experience" (21.4 %). We found the gynecology experiences was key factor for women with visual impairment to use Pap smear, especially the experiences was during 1 year (OR = 4). Associated factors and barriers to receive Pap smear screening test for women with visual impairment can be addressed through interventions aimed at improving on cognitions and attitudes for cervical cancer risk factors. Our study would be as a reference resource for erasing the barriers and inequality among the visually disabled women.

  19. The crypto-Hermitian smeared-coordinate representation of wave functions

    NASA Astrophysics Data System (ADS)

    Znojil, Miloslav

    2011-08-01

    In discrete-coordinate quantum models the kinematical observable of position need not necessarily be chosen local (i.e., diagonal). Its smearing is selected in the nearest-neighbor form of a real asymmetric (i.e., crypto-Hermitian) tridiagonal matrix Qˆ. Via Gauss-Hermite illustrative example we show how such an option restricts the class of admissible dynamical observables (sampled here just by the Hamiltonian).

  20. Prioritizing prevention: culture, context, and cervical cancer screening among Vietnamese American women.

    PubMed

    Gregg, Jessica; Nguyen-Truong, Connie K Y; Wang, Pei-ru; Kobus, Amy

    2011-12-01

    Few studies have investigated what Vietnamese American women believe about the Pap smear or how those beliefs might influence behavior. Thirty-one Vietnamese American women recruited through snowball sampling were interviewed about their beliefs regarding the Pap smear. Interviews were qualitatively analyzed using a theoretically informed, inductive approach. The women interviewed emphasized the importance of primary prevention of disease through culturally-informed personal health regimens. They were also largely unfamiliar with the Pap smear, but believed that gynecological exams in general were effective and necessary for disease detection. Finally, when access to gynecological care was difficult, women's faith in their own preventive behaviors helped alleviate their concerns over lack of care. While culturally associated beliefs do not simply "cause" Vietnamese American women to seek or avoid Pap smears, they do influence screening behaviors to a greater or lesser degree, depending on other contextual variables.

  1. Cost-effectiveness of liquid-based cytology with or without hybrid-capture II HPV test compared with conventional Pap smears: a study by the French Society of Clinical Cytology.

    PubMed

    Cochand-Priollet, Béatrix; Cartier, Isabelle; de Cremoux, Patricia; Le Galès, Catherine; Ziol, Marianne; Molinié, Vincent; Petitjean, Alain; Dosda, Anne; Merea, Estelle; Biaggi, Annonciade; Gouget, Isabelle; Arkwright, Sylviane; Vacher-Lavenu, Marie-Cécile; Vielh, Philippe; Coste, Joël

    2005-11-01

    Many articles concerning conventional Pap smears, ThinPrep liquid-based cytology (LBC) and Hybrid-Capture II HPV test (HC II) have been published. This study, carried out by the French Society of Clinical Cytology, may be conspicuous for several reasons: it was financially independent; it compared the efficiency of the conventional Pap smear and LBC, of the conventional Pap smear and HC II, and included an economic study based on real costs; for all the women, a "gold standard" reference method, colposcopy, was available and biopsies were performed whenever a lesion was detected; The conventional Pap smear, the LBC (split-sample technique), the colposcopy, and the biopsies were done at the same time. This study included 2,585 women shared into two groups: a group A of a high-risk population, a group B of a screening population. The statistical analysis of the results showed that conventional Pap smears consistently had superior or equivalent sensitivity and specificity than LBC for the lesions at threshold CIN-I (Cervical Intraepithelial Neoplasia) or CIN-II or higher. It underlined the low specificity of the HC II. Finally, the LBC mean cost was never covered by the Social Security tariff.

  2. Incidence of smear-positive tuberculosis in Dabat, northern Ethiopia.

    PubMed

    Tadesse, T; Demissie, M; Berhane, Y; Kebede, Y; Abebe, M

    2013-05-01

    To determine the incidence of smear-positive tuberculosis (TB) in Dabat District, northern Ethiopia. Using a population-based longitudinal design, a TB surveillance system was initiated among 46,165 residents at the Dabat Health and Demographic Surveillance System site. Trained field workers visited each household every third month and interviewed all individuals aged ≥14 years using a uniform questionnaire to detect suspected cases of TB (cough ≥15 days), at which time two sputum (spot-morning) samples were collected for smear microscopy. A total of 281,820 person-months were observed during the 1-year period, which generated 74 smear-positive TB cases. The incidence of smear-positive TB was calculated at 311 per 100,000 person-years (95%CI 240-382). Higher rates were observed among females (incidence rate ratio [IRR] 2.08, 95%CI 1.24-3.52), persons with no schooling (IRR 2.74, 95%CI 1.11-6.78) and urban residents (IRR 2.39, 95%CI 1.39-4.12). The incidence of smear-positive TB is high in Dabat District, suggesting a high risk of transmission in the communities. TB control programmes thus need to improve case-finding mechanisms at the community level in Ethiopia, with greater emphasis on risk groups.

  3. High-Fidelity Geometric Modeling and Mesh Generation for Mechanics Characterization of Polycrystalline Materials

    DTIC Science & Technology

    2015-01-07

    and anisotropic quadrilateral meshes, which can be used as the control mesh for high-order T- spline surface modeling. Archival publications (published...anisotropic T-meshes for the further T- spline surface construction. Finally, a gradient flow-based method is developed to improve the T-mesh quality...shade-off. Halos are bright or dark thin regions around the boundary of the sample. These false edges around the object make many segmentation

  4. Comparative analysis of endodontic smear layer removal efficacy of 17% ethylenediaminetetraacetic acid, 7% maleic acid, and 2% chlorhexidine using scanning electron microscope: An in vitro study.

    PubMed

    Attur, Kailash; Joy, Mathew T; Karim, Riyas; Anil Kumar, V J; Deepika, C; Ahmed, Haseena

    2016-08-01

    The aim of the present study was to evaluate the efficiency of different endodontic irrigants in the removal of smear layer through scanning electron microscopic image analysis. The present in vitro study was carried out on 45 single-rooted extracted human mandibular premolar teeth with single canal and complete root formation. Teeth were randomly assigned to three groups with 15 teeth in each group. Group I samples were irrigated with 17% ethylenediaminetetraacetic (EDTA) irrigation, Group II with 7% maleic acid irrigation, and Group III with 2% chlorhexidine irrigation. Scanning electron microscope evaluation was done for the assessment of smear layer removal in the coronal, middle, and apical thirds. Comparison of the smear layer removal between the three different groups was done by Kruskal-Wallis test, followed by Mann-Whitney U test for comparing individual groups. A P value less than 0.05 was considered to be statistically significant. Statistically significant difference was seen between the two test groups (17% EDTA vs. 7% maleic acid and 17% EDTA vs. 2% chlorhexidine) in smear layer removal at coronal, middle, and apical thirds of the root canal. The most efficient smear layer removal was seen in Group I with 17% EDTA irrigation compared with other groups (P < 0.05) and the least by 2% chlorhexidine. The present study shows that 17% EDTA efficiently removes the smear layer from root canal walls.

  5. Effects of overnight refrigeration on the microscopic evaluation of sputum.

    PubMed Central

    Penn, R L; Silberman, R

    1984-01-01

    Microscopic evaluation of sputum permits selection of specimens suitable for culture, assessment of likely pathogens, and the best interpretation of culture results. We prospectively evaluated 50 sputum specimens which were promptly submitted to our clinical laboratory; smears and cultures were performed both immediately and after 20 h of refrigeration. Specimens were grouped according to the numbers of squamous epithelial cells and neutrophils per low-power field present on coded Gram-stained smears. The numbers of bacteria in five oil immersion fields were used to characterize smears for predominant, mixed, or scanty forms. After refrigeration, only three specimens changed group from a definite loss of squamous epithelial cells, and only two changed group from a definite loss of neutrophils. Based on cellular composition, the majority of samples would have been processed identically both before and after refrigeration. In contrast, organism forms detected on smears and their relative quantities were dramatically altered after refrigeration. A predominant smear form was gained in 11 and lost in 8 refrigerated specimens. The frequent changes on smears observed overall resulted from both increases and decreases in numbers of bacteria and yeasts. The majority of sputum culture results were insignificantly affected by the refrigeration of specimens. We conclude that 20 h of refrigeration renders sputum useless for the microscopic evaluation of potential pathogens and the subsequent interpretation of culture results. However, overnight refrigeration does not affect the determination from smears of sputum suitability for culture based on cellular composition. PMID:6699145

  6. Occurrence of Trypanosoma cruzi in Maryland

    USGS Publications Warehouse

    Herman, C.M.; Bruce, J.I.

    1962-01-01

    During 1954-1960, 2005 mammals of 18 species collected at the Patuxent Wildlife Research Center, Maryland, were examined for trypanosomes. T. cruzi was found in 10 raccoons between October 31 and November 30. Infection occurred in 2 percent of all raccoons sampled, and in 11.3 percent of the 80 raccoons sampled in November. Examination was by direct smears, stained smears and cultures of heart blood. Although, in previous studies, at least two experimentally infected raccoons exhibited extended parasitemia (14 and 8 weeks), no such continuing parasitemia was observed in the natural infections. No trypanosomes were found in any of the other mammals examined.

  7. Simplified Pan-species Real-time PCR-based Detection of Plasmodium Spp. in Blood Smear

    PubMed Central

    HASSANPOUR, Gholamreza; MIRHENDI, Hossein; MOHEBALI, Mehdi; RAEISI, Ahmad; ZERAATI, Hojjat; KESHAVARZ, Hossein

    2016-01-01

    Background: We aimed to quicken and simplify the detection of Plasmodium in blood samples by developing and testing a pan-Plasmodium real-time PCR for accurate screening of individuals suspected of malaria. Methods: A single primer/probe set for pan-species Plasmodium-specific real time PCR targeting a conserved region of the small subunit 18S ribosomal DNA was designed and evaluated for rapid diagnosis and screening of malaria infections using dried blood smears. FTA cards were used for rapid and simple DNA extraction. Results: The primers and probes showed a positive response with the DNA extracted from bloods infected with P. falciparum and P. vivax but not with DNA extracted from various smears from uninfected blood samples. Seven positive cases positive by both microscopy and nested PCR were found among 280 blood samples taken from in South and Southeast Iran. Five samples were identified as positive for P. vivax and two as positive for P. falciparum. All positive samples were positive by real-time PCR. Furthermore, all 38-blood samples positive by microscopy were positive by real-time PCR. No microscopy-negative samples were positive by real-time PCR. Conclusion: By using a simple FTA card for DNA extraction and by application of the real-time PCR developed in this study, sensitivity similar to nested-PCR and microscopy was achieved. This format simplifies the detection of Plasmodium in large numbers of samples. PMID:28127357

  8. Molecular Detection of Plasmodium malariae/Plasmodium brasilianum in Non-Human Primates in Captivity in Costa Rica.

    PubMed

    Fuentes-Ramírez, Alicia; Jiménez-Soto, Mauricio; Castro, Ruth; Romero-Zuñiga, Juan José; Dolz, Gaby

    2017-01-01

    One hundred and fifty-two blood samples of non-human primates of thirteen rescue centers in Costa Rica were analyzed to determine the presence of species of Plasmodium using thick blood smears, semi-nested multiplex polymerase chain reaction (SnM-PCR) for species differentiation, cloning and sequencing for confirmation. Using thick blood smears, two samples were determined to contain the Plasmodium malariae parasite, with SnM-PCR, a total of five (3.3%) samples were positive to P. malariae, cloning and sequencing confirmed both smear samples as P. malariae. One sample amplified a larger and conserved region of 18S rDNA for the genus Plasmodium and sequencing confirmed the results obtained microscopically and through SnM-PCR tests. Sequencing and construction of a phylogenetic tree of this sample revealed that the P. malariae/P. brasilianum parasite (GenBank KU999995) found in a howler monkey (Alouatta palliata) is identical to that recently reported in humans in Costa Rica. The SnM-PCR detected P. malariae/P. brasilianum parasite in different non-human primate species in captivity and in various regions of the southern Atlantic and Pacific coast of Costa Rica. The similarity of the sequences of parasites found in humans and a monkey suggests that monkeys may be acting as reservoirs of P.malariae/P. brasilianum, for which reason it is important, to include them in control and eradication programs.

  9. Scalable hierarchical PDE sampler for generating spatially correlated random fields using nonmatching meshes: Scalable hierarchical PDE sampler using nonmatching meshes

    DOE PAGES

    Osborn, Sarah; Zulian, Patrick; Benson, Thomas; ...

    2018-01-30

    This work describes a domain embedding technique between two nonmatching meshes used for generating realizations of spatially correlated random fields with applications to large-scale sampling-based uncertainty quantification. The goal is to apply the multilevel Monte Carlo (MLMC) method for the quantification of output uncertainties of PDEs with random input coefficients on general and unstructured computational domains. We propose a highly scalable, hierarchical sampling method to generate realizations of a Gaussian random field on a given unstructured mesh by solving a reaction–diffusion PDE with a stochastic right-hand side. The stochastic PDE is discretized using the mixed finite element method on anmore » embedded domain with a structured mesh, and then, the solution is projected onto the unstructured mesh. This work describes implementation details on how to efficiently transfer data from the structured and unstructured meshes at coarse levels, assuming that this can be done efficiently on the finest level. We investigate the efficiency and parallel scalability of the technique for the scalable generation of Gaussian random fields in three dimensions. An application of the MLMC method is presented for quantifying uncertainties of subsurface flow problems. Here, we demonstrate the scalability of the sampling method with nonmatching mesh embedding, coupled with a parallel forward model problem solver, for large-scale 3D MLMC simulations with up to 1.9·109 unknowns.« less

  10. Scalable hierarchical PDE sampler for generating spatially correlated random fields using nonmatching meshes: Scalable hierarchical PDE sampler using nonmatching meshes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osborn, Sarah; Zulian, Patrick; Benson, Thomas

    This work describes a domain embedding technique between two nonmatching meshes used for generating realizations of spatially correlated random fields with applications to large-scale sampling-based uncertainty quantification. The goal is to apply the multilevel Monte Carlo (MLMC) method for the quantification of output uncertainties of PDEs with random input coefficients on general and unstructured computational domains. We propose a highly scalable, hierarchical sampling method to generate realizations of a Gaussian random field on a given unstructured mesh by solving a reaction–diffusion PDE with a stochastic right-hand side. The stochastic PDE is discretized using the mixed finite element method on anmore » embedded domain with a structured mesh, and then, the solution is projected onto the unstructured mesh. This work describes implementation details on how to efficiently transfer data from the structured and unstructured meshes at coarse levels, assuming that this can be done efficiently on the finest level. We investigate the efficiency and parallel scalability of the technique for the scalable generation of Gaussian random fields in three dimensions. An application of the MLMC method is presented for quantifying uncertainties of subsurface flow problems. Here, we demonstrate the scalability of the sampling method with nonmatching mesh embedding, coupled with a parallel forward model problem solver, for large-scale 3D MLMC simulations with up to 1.9·109 unknowns.« less

  11. Surface modification of polypropylene mesh devices with cyclodextrin via cold plasma for hernia repair: Characterization and antibacterial properties

    NASA Astrophysics Data System (ADS)

    Sanbhal, Noor; Mao, Ying; Sun, Gang; Xu, Rui Fang; Zhang, Qian; Wang, Lu

    2018-05-01

    Light weight polypropylene (PP) mesh is the most widely used implant among all other synthetic meshes for hernia repair. However, infection is the complication associated to all synthetic meshes after hernia repair. Thus, to manage mesh related infection; antibacterial drug is generally loaded to surgical implants to supply drug locally in mesh implanted site. Nevertheless, PP mesh restricts the loading of antibacterial drug at operated area due to its low wettability. The aim of this study was to introduce a novel antimicrobial PP mesh modified with β-cyclodextrine (CD) and loaded with antimicrobial agent for infection prevention. A cold oxygen plasma treatment was able to activate the surfaces of polypropylene fibers, and then CD was incorporated onto the surfaces of PP fibers. Afterward, triclosan, as a model antibacterial agent, was loaded into CD cavity to provide desired antibacterial functions. The modified polypropylene mesh samples CD-Tric-1, CD-Tric-3 exhibited excellent inhibition zone and continuous antibacterial efficacy against E. coli and S. aureus up to 6 and 7 days respectively. Results of AFM, SEM, FTIR and antibacterial tests evidenced that oxygen plasma process is necessary to increase chemical connection between CD molecules and PP fibers. The samples were also characterized by using EDX, XRD, TGA, DSC and water contact angle.

  12. Oral exfoliative cytology in the diagnosis of paracoccidioidomycosis.

    PubMed

    de Araújo, M S; Mesquita, R A; Corrêa, L; de Sousa, S O

    2001-01-01

    To assess the efficacy of conventional oral exfoliative cytology as a diagnostic tool in paracoccidioidomycosis. Cytologic smears and incisional biopsies were obtained from 10 patients with a clinical suspicion and oral manifestations of paracoccidioidomycosis. Cytologic smears and sections of the incisional biopsy underwent methenamine silver staining for fungi according to the Gomori-Grocott method. The dry glass slides were examined at 400 or 1,000 x magnification, and the presence and shape of yeasts of Paracoccidioides brasiliensis were investigated. Yeasts of the fungus P brasiliensis were clearly identified in cytologic smears and sections from incisional biopsies in all cases analyzed (100.0%). Cytology of oral samples proved an effective diagnostic method for the detection of paracoccidioidomycosis in humans.

  13. Efficiency of Different Endodontic Irrigation and Activation Systems in Removal of the Smear Layer: A Scanning Electron Microscopy Study.

    PubMed

    Karade, Priyatam; Chopade, Rutuja; Patil, Suvarna; Hoshing, Upendra; Rao, Madhukar; Rane, Neha; Chopade, Aditi; Kulkarni, Anish

    2017-01-01

    This in vitro study was designed to evaluate and compare different endodontic irrigation and activation systems for removal of the intracanal smear layer. Forty recently extracted, non-carious human intact single rooted premolars were selected and divided into five groups ( n =10) according to the root canal irrigation systems; syringe and needle irrigation (CTR), sonic irrigation, passive ultrasonic irrigation (PUI) and EndoVac irrigation system. All groups were prepared to #40 apical size with K-files. Each sample was subjected to final irrigation by using four different irrigation/activation systems. After splitting the samples, one half of each root was selected for examination under scanning electron microscope (SEM). The irrigation systems were compared using the Fisher's exact test with the level of significance set at 0.05. The four groups did not differ from each other in the coronal and mid-root parts of the canal. In the apical part of the canal none of the methods could completely remove all the smear layer but EndoVac system showed significantly better removal of smear layer and debris than the other methods. Within the limitations of the present study, the EndoVac system cleaned the apical part of the canal more efficiently than sonic, ultrasonic and syringe and needle irrigation.

  14. Rapid intra-operative diagnosis of kidney cancer by attenuated total reflection infrared spectroscopy of tissue smears.

    PubMed

    Pucetaite, Milda; Velicka, Martynas; Urboniene, Vidita; Ceponkus, Justinas; Bandzeviciute, Rimante; Jankevicius, Feliksas; Zelvys, Arunas; Sablinskas, Valdas; Steiner, Gerald

    2018-05-01

    Herein, a technique to analyze air-dried kidney tissue impression smears by means of attenuated total reflection infrared (ATR-IR) spectroscopy is presented. Spectral tumor markers-absorption bands of glycogen-are identified in the ATR-IR spectra of the kidney tissue smear samples. Thin kidney tissue cryo-sections currently used for IR spectroscopic analysis lack such spectral markers as the sample preparation causes irreversible molecular changes in the tissue. In particular, freeze-thaw cycle results in degradation of the glycogen and reduction or complete dissolution of its content. Supervised spectral classification was applied to the recorded spectra of the smears and the test spectra were classified with a high accuracy of 92% for normal tissue and 94% for tumor tissue, respectively. For further development, we propose that combination of the method with optical fiber ATR probes could potentially be used for rapid real-time intra-operative tissue analysis without interfering with either the established protocols of pathological examination or the ordinary workflow of operating surgeon. Such approach could ensure easier transition of the method to clinical applications where it may complement the results of gold standard histopathology examination and aid in more precise resection of kidney tumors. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. The value of Tzanck smear test in diagnosis of erosive, vesicular, bullous, and pustular skin lesions.

    PubMed

    Durdu, Murat; Baba, Mete; Seçkin, Deniz

    2008-12-01

    Tzanck smear is generally used for the diagnosis of the pemphigus group of autoimmune bullous diseases and mucocutaneous herpesvirus infections. There are only a few studies in the literature investigating its diagnostic value. We aimed to investigate Tzanck smear findings and to determine the diagnostic value of this test in moist (erosive, vesicular, bullous, and pustular) skin lesions. We also aimed to develop an algorithmic approach for the diagnosis of these types of skin lesions according to the Tzanck smear findings. Samples were stained with May-Grünwald-Giemsa and evaluated by the same dermatologist. In some patients, methylene blue and Gram staining or direct immunofluorescence examinations were additionally performed. In all of the study cases, after the evaluation of clinical and laboratory findings (including, when appropriate, potassium hydroxide examination; viral serology; bacterial and fungal cultures; histopathology; direct and indirect immunofluorescence; patch testing), the definite diagnosis was established. We also determined the sensitivity and the specificity of certain Tzanck smear findings. Tzanck smear was performed in a total of 400 patients with moist skin lesions. The sensitivities of multinucleated giant cells and acantholytic cells in herpetic infections, dyskeratotic acantholytic cells and cocci in bullous impetigo, pseudohyphae in candidiasis, acantholytic cells in pemphigus and more than 10 tadpole cells (magnification x100) in spongiotic dermatitis were 84.7%, 92%, 100%, 100%, and 81.5%, respectively. Because Tzanck smears were evaluated by the same dermatologist, no comment could be made regarding the interobserver reliability of this test and how the level of experience with this technique might affect the results. Also, the sensitivity and the specificity of Tzanck smear test findings for certain diseases could not be calculated because of an insufficient number of patients. The Tzanck smear test is an inexpensive, useful, and an easy diagnostic tool for certain skin diseases.

  16. Debris Evaluation after Root Canal Shaping with Rotating and Reciprocating Single-File Systems

    PubMed Central

    Dagna, Alberto; Gastaldo, Giulia; Beltrami, Riccardo; Poggio, Claudio

    2016-01-01

    This study evaluated the root canal dentine surface by scanning electron microscope (SEM) after shaping with two reciprocating single-file NiTi systems and two rotating single-file NiTi systems, in order to verify the presence/absence of the smear layer and the presence/absence of open tubules along the walls of each sample; Forty-eight single-rooted teeth were divided into four groups and shaped with OneShape (OS), F6 SkyTaper (F6), WaveOne (WO) and Reciproc and irrigated using 5.25% NaOCl and 17% EDTA. Root canal walls were analyzed by SEM at a standard magnification of 2500×. The presence/absence of the smear layer and the presence/absence of open tubules at the coronal, middle, and apical third of each canal were estimated using a five-step scale for scores. Numeric data were analyzed using Kruskal-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05; The Kruskal-Wallis ANOVA for debris score showed significant differences among the NiTi systems (P < 0.05). The Mann-Whitney test confirmed that reciprocating systems presented significantly higher score values than rotating files. The same results were assessed considering the smear layer scores. ANOVA confirmed that the apical third of the canal maintained a higher quantity of debris and smear layer after preparation of all the samples; Single-use NiTi systems used in continuous rotation appeared to be more effective than reciprocating instruments in leaving clean walls. The reciprocating systems produced more debris and smear layer than rotating instruments. PMID:27763503

  17. Clinical evaluation of the Abbott RealTime MTB Assay for direct detection of Mycobacterium tuberculosis-complex from respiratory and non-respiratory samples.

    PubMed

    Hinić, Vladimira; Feuz, Kinga; Turan, Selda; Berini, Andrea; Frei, Reno; Pfeifer, Karin; Goldenberger, Daniel

    2017-05-01

    Rapid and reliable diagnosis is crucial for correct management of tuberculosis. The Abbott RealTime MTB Assay represents a novel qualitative real-time PCR assay for direct detection of M. tuberculosis-complex (MTB) DNA from respiratory samples. The test targets two highly conserved sequences, the multi-copy insertion element IS6110 and the protein antigen B (PAB) gene of MTB, allowing even the detection of IS6610-deficient strains. We evaluated this commercial diagnostic test by analyzing 200 respiratory and, for the first time, 87 non-respiratory clinical specimens from our tertiary care institution and compared its results to our IS6110-based in-house real-time PCR for MTB as well as MTB culture. Overall sensitivity for Abbott RealTime MTB was 100% (19/19) in smear positive and 87.5% (7/8) in smear negative specimens, while the specificity of the assay was 100% (260/260). For both non-respiratory smear positive and smear negative specimens Abbott RealTime MTB tests showed 100% (8/8) sensitivity and 100% (8/8) specificity. Cycle threshold (Ct) value analysis of 16 MTB positive samples showed a slightly higher Ct value of the Abbott RealTime MTB test compared to our in-house MTB assay (mean delta Ct = 2.55). In conclusion, the performance of the new Abbott RealTime MTB Assay was highly similar to culture and in-house MTB PCR. We document successful analysis of 87 non-respiratory samples with the highly automated Abbott RealTime MTB test with no inhibition observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Sputum fungal smear

    MedlinePlus

    ... in the test sample. Some labs use different measurements or test different samples. Talk to your doctor ... A.D.A.M. follows rigorous standards of quality and accountability. A.D.A.M. is among ...

  19. High-fidelity meshes from tissue samples for diffusion MRI simulations.

    PubMed

    Panagiotaki, Eleftheria; Hall, Matt G; Zhang, Hui; Siow, Bernard; Lythgoe, Mark F; Alexander, Daniel C

    2010-01-01

    This paper presents a method for constructing detailed geometric models of tissue microstructure for synthesizing realistic diffusion MRI data. We construct three-dimensional mesh models from confocal microscopy image stacks using the marching cubes algorithm. Random-walk simulations within the resulting meshes provide synthetic diffusion MRI measurements. Experiments optimise simulation parameters and complexity of the meshes to achieve accuracy and reproducibility while minimizing computation time. Finally we assess the quality of the synthesized data from the mesh models by comparison with scanner data as well as synthetic data from simple geometric models and simplified meshes that vary only in two dimensions. The results support the extra complexity of the three-dimensional mesh compared to simpler models although sensitivity to the mesh resolution is quite robust.

  20. Sensitivity of nested-PCR for plasmodium detection in pooled whole blood samples and its usefulness to blood donor screening in endemic areas.

    PubMed

    de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen

    2014-04-01

    Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Fecal smear

    MedlinePlus

    ... the sample. You can collect the sample: On plastic wrap. Place the wrap loosely over the toilet bowl ... For children wearing diapers: Line the diaper with plastic wrap. Position the plastic wrap so that it will ...

  2. Standardization of a TaqMan-based real-time PCR for the detection of Mycobacterium tuberculosis-complex in human sputum.

    PubMed

    Barletta, Francesca; Vandelannoote, Koen; Collantes, Jimena; Evans, Carlton A; Arévalo, Jorge; Rigouts, Leen

    2014-10-01

    Real-time polymerase chain reaction (qPCR) was optimized for detecting Mycobacterium tuberculosis in sputum. Sputum was collected from patients (N = 112) with suspected pulmonary tuberculosis, tested by smear microscopy, decontaminated, and split into equal aliquots that were cultured in Löwenstein-Jensen medium and tested by qPCR for the small mobile genetic element IS6110. The human ERV3 sequence was used as an internal control. 3 of 112 (3%) qPCR failed. For the remaining 109 samples, qPCR diagnosed tuberculosis in 79 of 84 patients with culture-proven tuberculosis, and sensitivity was greater than microscopy (94% versus 76%, respectively, P < 0.05). The qPCR sensitivity was similar (P = 0.9) for smear-positive (94%, 60 of 64) and smear-negative (95%, 19 of 20) samples. The qPCR was negative for 24 of 25 of the sputa with negative microscopy and culture (diagnostic specificity 96%). The qPCR had 99.5% sensitivity and specificity for 211 quality control samples including 84 non-tuberculosis mycobacteria. The qPCR cost ∼5US$ per sample and provided same-day results compared with 2-6 weeks for culture. © The American Society of Tropical Medicine and Hygiene.

  3. Active case finding of undetected tuberculosis among chronic coughers in a slum setting in Kampala, Uganda

    PubMed Central

    Sekandi, J. N.; Neuhauser, D.; Smyth, K.; Whalen, C. C.

    2010-01-01

    SUMMARY SETTING Kisenyi slum in peri-urban Kampala, Uganda. OBJECTIVES Using chronic cough (≥2 weeks) inquiry as a screening tool to identify undetected smear-positive tuberculosis (TB) cases and to describe the characteristics of smear-positive TB cases detected by active case finding. DESIGN A house-to-house survey was conducted in five randomly selected villages in Kampala between June and August 2005. A sample of households was visited; adults aged ≥15 years were consecutively interviewed to identify those with chronic cough. Three sputum specimens were collected and examined by smear microscopy. RESULTS Among 930 individuals, we identified 189 (20%) chronic coughers. Of these, we found 33 (18%) undiagnosed smear-positive cases. The newly detected cases had an even sex distribution (P = 0.47), a median age of 30 years, a median cough duration of 1 month and 55% had acid-fast bacilli 1+ sputum smear grade. CONCLUSION These findings suggest that active case finding could supplement DOTS to yield additional smear-positive TB cases, lead to early diagnosis and thus shorten the duration of infectiousness before effective chemotherapy is initiated. In communities such as Kisenyi, this is a feasible strategy that may prove useful for TB control, but its cost-effectiveness needs to be evaluated. Early health care seeking for cough should be emphasized. PMID:19335958

  4. Attitudes and factors affecting acceptability of self-administered cervicovaginal sampling for human papillomavirus (HPV) genotyping as an alternative to Pap testing among multiethnic Malaysian women.

    PubMed

    Ma'som, Mahirah; Bhoo-Pathy, Nirmala; Nasir, Nazrila Hairizan; Bellinson, Jerome; Subramaniam, Shridevi; Ma, Yuntong; Yap, Siew-Hwei; Goh, Pik-Pin; Gravitt, Patti; Woo, Yin Ling

    2016-08-04

    The objective of this study was to determine the attitudes and acceptability of self-administered cervicovaginal sampling compared with conventional physician-acquired Papanicolaou (Pap) smear among multiethnic Malaysian women. A cross-sectional study was carried out via interviewer-administered surveys from August 2013 through August 2015 at five government-run, urban health clinics in the state of Selangor. Subjects were participants from an ongoing community-based human papillomavirus (HPV) prevalence study who answered a standard questionnaire before and after self-sampling. The cervicovaginal self-sampling for HPV genotyping was performed using a simple brush ('Just for Me'; Preventive Oncology International, Hong Kong). Detailed data on sociodemographics, previous Pap smear experience, and attitudes towards self-administered cervicovaginal sampling were collected and analysed. Acceptability was inferred using a five-item Likert scale that included six different subjective descriptives: experience, difficulty, convenience, embarrassment, discomfort or pain, and confidence in collecting one's own sample. Of the 839 participants, 47.9% were Malays, followed by 30.8% Indians, 18.8% Chinese and 2.5% from other ethnicities. The median age of the participants was 38 years (IQR 30-48). Some 68.2% of participants indicated a preference for self-sampling over the Pap test, with 95% indicating willingness to follow-up a positive result at the hospital. Age, ethnicity and previous Pap test experience were significant independent factors associated with preference for self-sampling. The older the individual, the less likely they were to prefer self-sampling (adjusted OR 0.94, 95% CI 0.90 to 0.98). The Chinese were less likely to prefer self-sampling (72.6%) than the Malays (85.1%) (adjusted OR 0.57, 95% CI 0.33 to 0.98, p=0.004). Participants who had never undergone a Pap smear were also more likely to prefer self-sampling (88.5%) than women who had undergone a previous Pap (80.9%) (adjusted OR 0.06, 95% CI 0.35 to 0.87). Overall, urban Malaysian women from multiethnic backgrounds found self-sampling to be an acceptable alternative to Pap smear. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Evaluation of smear layer removal and marginal adaptation of root canal sealer after final irrigation using ethylenediaminetetraacetic, peracetic, and etidronic acids with different concentrations.

    PubMed

    Ulusoy, Özgür İlke; Zeyrek, Salev; Çelik, Bülent

    2017-07-01

    The purpose of this study was to investigate the effects of different irrigation solutions on the smear layer removal and marginal adaptation of a resin-based sealer to root canal dentine. A total of 152 instrumented roots were irrigated with the following irrigants: 9,18% etidronic acid (HEBP), 0.5, 1,2% peracetic acid (PAA), 17% ethylenediaminetetraacetic acid (EDTA), saline. The amount of smear layer was evaluated using scanning electron microscope (SEM) in seventy root samples. Eighty-two roots were filled with AH Plus and gutta-percha. Slices obtained from apical third of each specimen were viewed with SEM to assess marginal adaptation. Use of 9% and 18% HEBP resulted in more efficient smear layer removal in the apical third than the other chelators (p < 0.05). Higher smear layer scores in the coronal and middle thirds were obtained from 0.5%, 1% PAA groups. Regarding marginal adaptation, 18% HEBP group showed the lowest gap size values (p < 0.05), and better marginal adaptation. Etidronic acid is a promising candidate for final irrigation of root canals. © 2017 Wiley Periodicals, Inc.

  6. Cross-sectional studies of tuberculosis prevalence in Cambodia between 2002 and 2011.

    PubMed

    Mao, Tan Eang; Okada, Kosuke; Yamada, Norio; Peou, Satha; Ota, Masaki; Saint, Saly; Kouet, Pichenda; Chea, Manith; Keo, Sokonth; Pheng, Sok Heng; Tieng, Sivanna; Khun, Kim Eam; Sugamoto, Tetsuhiro; Matsumoto, Hiroko; Yoshiyama, Takashi; Ito, Kunihiko; Onozaki, Ikushi

    2014-08-01

    To measure trends in the pulmonary tuberculosis burden between 2002 and 2011 and to assess the impact of the DOTS (directly observed treatment, short-course) strategy in Cambodia. Cambodia's first population-based nationwide tuberculosis survey, based on multistage cluster sampling, was conducted in 2002. The second tuberculosis survey, encompassing 62 clusters, followed in 2011. Participants aged 15 years or older were screened for active pulmonary tuberculosis with chest radiography and/or for tuberculosis symptoms. For diagnostic confirmation, sputum smear and culture were conducted on those whose screening results were positive. Of the 40,423 eligible subjects, 37,417 (92.6%) participated in the survey; 103 smear-positive cases and 211 smear-negative, culture-positive cases were identified. The weighted prevalences of smear-positive tuberculosis and bacteriologically-positive tuberculosis were 271 (95% confidence interval, CI: 212-348) and 831 (95% CI: 707-977) per 100,000 population, respectively. Tuberculosis prevalence was higher in men than women and increased with age. A 38% decline in smear-positive tuberculosis (P = 0.0085) was observed with respect to the 2002 survey, after participants were matched by demographic and geographical characteristics. The prevalence of symptomatic, smear-positive tuberculosis decreased by 56% (P = 0.001), whereas the prevalence of asymptomatic, smear-positive tuberculosis decreased by only 7% (P = 0.7249). The tuberculosis burden in Cambodia has declined significantly, most probably because of the decentralization of DOTS to health centres. To further reduce the tuberculosis burden in Cambodia, tuberculosis control should be strengthened and should focus on identifying cases without symptoms and in the middle-aged and elderly population.

  7. Cervical cytology screening. How can we improve rates among First Nations women in urban British Columbia?

    PubMed Central

    Hislop, T. G.; Clarke, H. F.; Deschamps, M.; Joseph, R.; Band, P. R.; Smith, J.; Le, N.; Atleo, R.

    1996-01-01

    OBJECTIVE: To determine Pap smear screening rates among urban First Nations women in British Columbia; to identify facilitators and barriers; and to develop, implement, and evaluate specific interventions to improve Pap smear screening in Vancouver. DESIGN: Computer records of band membership lists and the Cervical Cytology Screening Program registry were compared to determine screening rates; personal interviews and community meetings identified facilitators and barriers to urban screening programs. A community advisory committee and the project team collaborated on developing specific interventions. SETTING AND PARTICIPANTS: Purposive sample of British Columbia First Nations women, focusing on women living in Vancouver. INTERVENTIONS: Poster, art card, and follow-up pamphlet campaign; articles in First Nations community papers; community meetings; and Pap smear screening clinics for First Nations women. MAIN OUTCOME MEASURES: Pap smear screening rates among BC First Nations women according to residence and reasons for not receiving Pap smears. RESULTS: Pap smear screening rates were substantially lower among First Nations women than among other British Columbia women; older women had even lower rates. No clear differences were found among First Nations women residing on reserves, residing in Vancouver, or residing off reserves elsewhere in British Columbia. Facilitators and barriers to screening were similar among women residing on reserves and in Vancouver. Many First Nations women are greatly affected by health care providers' attitudes, abilities to provide clear information, and abilities to establish trusting relationships. CONCLUSIONS: Family physicians are an important source of information and motivation for Pap smear screening among First Nations women. PMID:8828873

  8. Solid Hydrocarbon Assisted Reduction: A New Process of Generating Micron Scale Metal Particles

    DTIC Science & Technology

    2015-03-01

    Figure 4.  Stainless Steel Mesh and Sample Containment ................................. 14  Figure 5.  Zero Background XRD Sample Holder...from the oven. Later experiments with iron oxide employed T304 stainless steel mesh, basically fashioned into the same shape as that shown for...200X200S0021W48T by TWP Inc. in Berkeley, California. The stainless steel mesh was folded in three segments similar to the Grafoil it replaced. 14 Figure 4

  9. Detection of enteropathogens associated with travelers’ diarrhea using a multiplex Luminex-based assay performed on stool samples smeared on Whatman FTA Elute cards

    PubMed Central

    Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R

    2015-01-01

    We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman FTA Elute cards smeared with stool containing pathogens associated with travelers’ diarrhea. LoDs ranged between 102-105 CFU, PFU or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoD increased with prolonged storage of cards. PMID:26072151

  10. Mesh size effects on assessments of planktonic hydrozoan abundance and assemblage structure

    NASA Astrophysics Data System (ADS)

    Nogueira Júnior, Miodeli; Pukanski, Luis Eduardo de M.; Souza-Conceição, José M.

    2015-04-01

    The choice of appropriate mesh-size is paramount to accurately quantify planktonic assemblages, however there is no such information available for hydrozoans. Here planktonic hydrozoan abundance and assemblage structure were compared using 200 and 500 μm meshes at Babitonga estuary (S Brazil), throughout a year cycle. Species richness and Shannon-Wiener diversity were higher in the 200 μm mesh, while evenness was typically higher in the 500 μm. Assemblage structure was significantly different between meshes (PERMANOVA, P < 0.05; n = 72 pairs of samples) both regarding taxa and size composition. These discrepancies are due to significant underestimation of small hydromedusae by the coarse mesh, like Obelia spp., young Liriope tetraphylla, Podocoryna loyola and others. Yet, larger taxa like Eucheilota maculata and adult L. tetraphylla were more abundant in the coarse mesh on some occasions and others such as Blackfordia virginica and Muggiaea kochi were similarly represented in both meshes. Overall collection efficiency of the coarse mesh (CE500) was 14.4%, with monthly averages between 1.6% and 43.0%, in July (winter) and January (summer) respectively. Differences between the meshes were size-dependent; CE500 was ~ 0.3% for hydrozoans sizing < 0.5 mm, ~ 21% for those between 1 and 2 mm, ~ 56% for those between 2 and 4 mm, and nearly 100% for larger ones, reaching up to 312% for hydrozoans > 8 mm in October. These results suggest that both meshes have their drawbacks and the best choice would depend on the objectives of each study. Nevertheless species richness, total abundances and most taxa were better represented by the 200 μm mesh, suggesting that it is more appropriate to quantitatively sample planktonic hydrozoan assemblages.

  11. Anisotropic tubular filtering for automatic detection of acid-fast bacilli in Ziehl-Neelsen stained sputum smear samples

    NASA Astrophysics Data System (ADS)

    Raza, Shan-e.-Ahmed; Marjan, M. Q.; Arif, Muhammad; Butt, Farhana; Sultan, Faisal; Rajpoot, Nasir M.

    2015-03-01

    One of the main factors for high workload in pulmonary pathology in developing countries is the relatively large proportion of tuberculosis (TB) cases which can be detected with high throughput using automated approaches. TB is caused by Mycobacterium tuberculosis, which appears as thin, rod-shaped acid-fast bacillus (AFB) in Ziehl-Neelsen (ZN) stained sputum smear samples. In this paper, we present an algorithm for automatic detection of AFB in digitized images of ZN stained sputum smear samples under a light microscope. A key component of the proposed algorithm is the enhancement of raw input image using a novel anisotropic tubular filter (ATF) which suppresses the background noise while simultaneously enhancing strong anisotropic features of AFBs present in the image. The resulting image is then segmented using color features and candidate AFBs are identified. Finally, a support vector machine classifier using morphological features from candidate AFBs decides whether a given image is AFB positive or not. We demonstrate the effectiveness of the proposed ATF method with two different feature sets by showing that the proposed image analysis pipeline results in higher accuracy and F1-score than the same pipeline with standard median filtering for image enhancement.

  12. Comparative anti-microbial efficacy of Azadirachta indica irrigant with standard endodontic irrigants: A preliminary study

    PubMed Central

    Dutta, Arindam; Kundabala, Mala

    2014-01-01

    Objective: The anti-microbial efficacy of 2.5% sodium hypochlorite (SHC) and 0.2% chlorhexidine gluconate were compared with an experimental irrigant formulated from the Neem tree, Azadirachta indica A. Juss. Materials and Methods: A sample of 36 single rooted anterior teeth with periapical radiolucency and absence of response to vitality tests that required root canal treatment were selected for this study. The test irrigants and their combinations were assigned to five different groups and saline served as the control. Access cavities were prepared using an aseptic technique and samples collected for both anaerobic culture and Gram stained smears, followed by irrigation and sample collection again. The number of organisms were expressed in colony forming units/ml after 72 h of incubation; the smears were analyzed for their microbial loads and tissue clearance and assessed as per defined criteria. Results: Our results found the maximum reduction in microbial loads, when analyzed by culture method, with a combination of SHC and the experimental neem irrigant. Maximum tissue clearance on the Gram Stained smears was also found with the same combination. Conclusion: Neem irrigant has anti-microbial efficacy and can be considered for endodontic use. PMID:24778508

  13. Performance of Mycobacterium Growth Indicator Tube BACTEC 960 with Lowenstein-Jensen method for diagnosis of Mycobacterium tuberculosis at Ethiopian National Tuberculosis Reference Laboratory, Addis Ababa, Ethiopia.

    PubMed

    Diriba, Getu; Kebede, Abebaw; Yaregal, Zelalem; Getahun, Muluwork; Tadesse, Mengistu; Meaza, Abyot; Dagne, Zekarias; Moga, Shewki; Dilebo, Jibril; Gudena, Kebebe; Hassen, Mulu; Desta, Kassu

    2017-05-10

    Bacteriological confirmed active case detection remains the corner stone for diagnosing tuberculosis. Non-radiometric liquid culture system Mycobacterium Growth Indicator Tube with automated interface had been recommended by expert groups in addition to conventional solid culture media such as Lowenstein-Jensen. However in high burden resource limited countries advanced non-radiometric based tuberculosis diagnostic methods such as MGIT 960 is limited. Therefore we have evaluated the performance of MGIT 960 system compared to LJ for recovery of Mycobacterium complex (MTBC) from clinical specimens. A cross sectional study was conducted from a total of 908 samples between January 1st, 2013 to December 31st, 2014. Clinical specimens were processed following standard procedures and the final suspension was inoculated to MGIT tubes and LJ slant. Identification and confirmation of MTBC was done by ZN staining and SD Bioline test. Data was analyzed by SPSS version 20. The sensitivity, specificity, recovery rate and the average turnaround time to recover the organism was computed. From a total of 908 clinical specimens processed using both LJ and BACTEC MGIT liquid culture methods the recovery rate for LJ and MGIT, for smear positive samples was 66.7% (74/111) and 87.4% (97/ 111) respectively while for smear negative samples was 13.4% (108/797) and 17.4% (139/797) for LJ and MGIT methods respectively. The overall recovery rate for MGIT is significantly higher than LJ methods [26% (236/908; vs. 20%, 182/908, P = 0.002)]. The average turnaround time for smear positive samples was 16 and 31 days for MGIT and LJ respectively. Turnaround time for smear negative samples was 20 and 36 days for MGIT and LJ respectively. The overall agreement between MGIT and LJ was fairly good with Kappa value of 0.59 (P < 0.001). In the present study the contamination rate for MGIT is higher than the LJ methods, 15 and 9.3% respectively. The BACTEC MGIT liquid culture system has better MTBC recovery rate with shorter turnaround time for both smear positive and negative clinical specimens compared to Conventional LJ method. However, efforts should be made in order to reduce the high contamination rate in BACTEC MGIT system and to lesser extent to LJ methods.

  14. The counting of native blood cells by digital microscopy

    NASA Astrophysics Data System (ADS)

    Torbin, S. O.; Doubrovski, V. A.; Zabenkov, I. V.; Tsareva, O. E.

    2017-03-01

    An algorithm for photographic images processing of blood samples in its native state was developed to determine the concentration of erythrocytes, leukocytes and platelets without individual separate preparation of cells' samples. Special "photo templates" were suggested to use in order to identify red blood cells. The effect of "highlighting" of leukocytes, which was found by authors, was used to increase the accuracy of this type of cells counting. Finally to raise the resolution of platelets from leukocytes the areas of their photo images were used, but not their sizes. It is shown that the accuracy of cells counting for native blood samples may be comparable with the accuracy of similar studies for smears. At the same time the proposed native blood analysis simplifies greatly the procedure of sample preparation in comparison to smear, permits to move from the detection of blood cells ratio to the determination of their concentrations in the sample.

  15. Selective laser vaporization of polypropylene sutures and mesh

    NASA Astrophysics Data System (ADS)

    Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.

    2012-02-01

    Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.

  16. Molecular Detection of Plasmodium malariae/Plasmodium brasilianum in Non-Human Primates in Captivity in Costa Rica

    PubMed Central

    Fuentes-Ramírez, Alicia; Jiménez-Soto, Mauricio; Castro, Ruth; Romero-Zuñiga, Juan José

    2017-01-01

    One hundred and fifty-two blood samples of non-human primates of thirteen rescue centers in Costa Rica were analyzed to determine the presence of species of Plasmodium using thick blood smears, semi-nested multiplex polymerase chain reaction (SnM-PCR) for species differentiation, cloning and sequencing for confirmation. Using thick blood smears, two samples were determined to contain the Plasmodium malariae parasite, with SnM-PCR, a total of five (3.3%) samples were positive to P. malariae, cloning and sequencing confirmed both smear samples as P. malariae. One sample amplified a larger and conserved region of 18S rDNA for the genus Plasmodium and sequencing confirmed the results obtained microscopically and through SnM-PCR tests. Sequencing and construction of a phylogenetic tree of this sample revealed that the P. malariae/P. brasilianum parasite (GenBank KU999995) found in a howler monkey (Alouatta palliata) is identical to that recently reported in humans in Costa Rica. The SnM-PCR detected P. malariae/P. brasilianum parasite in different non-human primate species in captivity and in various regions of the southern Atlantic and Pacific coast of Costa Rica. The similarity of the sequences of parasites found in humans and a monkey suggests that monkeys may be acting as reservoirs of P.malariae/P. brasilianum, for which reason it is important, to include them in control and eradication programs. PMID:28125696

  17. Automated smear counting and data processing using a notebook computer in a biomedical research facility.

    PubMed

    Ogata, Y; Nishizawa, K

    1995-10-01

    An automated smear counting and data processing system for a life science laboratory was developed to facilitate routine surveys and eliminate human errors by using a notebook computer. This system was composed of a personal computer, a liquid scintillation counter and a well-type NaI(Tl) scintillation counter. The radioactivity of smear samples was automatically measured by these counters. The personal computer received raw signals from the counters through an interface of RS-232C. The software for the computer evaluated the surface density of each radioisotope and printed out that value along with other items as a report. The software was programmed in Pascal language. This system was successfully applied to routine surveys for contamination in our facility.

  18. A malaria diagnostic tool based on computer vision screening and visualization of Plasmodium falciparum candidate areas in digitized blood smears.

    PubMed

    Linder, Nina; Turkki, Riku; Walliander, Margarita; Mårtensson, Andreas; Diwan, Vinod; Rahtu, Esa; Pietikäinen, Matti; Lundin, Mikael; Lundin, Johan

    2014-01-01

    Microscopy is the gold standard for diagnosis of malaria, however, manual evaluation of blood films is highly dependent on skilled personnel in a time-consuming, error-prone and repetitive process. In this study we propose a method using computer vision detection and visualization of only the diagnostically most relevant sample regions in digitized blood smears. Giemsa-stained thin blood films with P. falciparum ring-stage trophozoites (n = 27) and uninfected controls (n = 20) were digitally scanned with an oil immersion objective (0.1 µm/pixel) to capture approximately 50,000 erythrocytes per sample. Parasite candidate regions were identified based on color and object size, followed by extraction of image features (local binary patterns, local contrast and Scale-invariant feature transform descriptors) used as input to a support vector machine classifier. The classifier was trained on digital slides from ten patients and validated on six samples. The diagnostic accuracy was tested on 31 samples (19 infected and 12 controls). From each digitized area of a blood smear, a panel with the 128 most probable parasite candidate regions was generated. Two expert microscopists were asked to visually inspect the panel on a tablet computer and to judge whether the patient was infected with P. falciparum. The method achieved a diagnostic sensitivity and specificity of 95% and 100% as well as 90% and 100% for the two readers respectively using the diagnostic tool. Parasitemia was separately calculated by the automated system and the correlation coefficient between manual and automated parasitemia counts was 0.97. We developed a decision support system for detecting malaria parasites using a computer vision algorithm combined with visualization of sample areas with the highest probability of malaria infection. The system provides a novel method for blood smear screening with a significantly reduced need for visual examination and has a potential to increase the throughput in malaria diagnostics.

  19. Rationale and design of the research project of the South Florida Center for the Reduction of Cancer Health Disparities (SUCCESS): study protocol for a randomized controlled trial.

    PubMed

    Carrasquillo, Olveen; McCann, Sheila; Amofah, Antony; Pierre, Larry; Rodriguez, Brendaly; Alonzo, Yisel; Ilangovan, Kumar; Gonzalez, Martha; Trevil, Dinah; Byrne, Margaret M; Koru-Sengul, Tulay; Kobetz, Erin

    2014-07-23

    In the United States certain minority groups, such as racial/ethnic immigrant women, are less likely than non-Hispanic White women to be screened for cervical cancer. Barriers to such care include health insurance, cost, knowledge, attitudes, health literacy, and cultural norms and practices. Among the most promising approaches to increase screening in these groups are patient navigators that can link women to sources of appropriate care. Another recent promising approach is using human papilloma virus (HPV) self-sampling. In this manuscript, we describe our National Cancer Institute-sponsored study testing such approaches among immigrant minority women. The South Florida Center for the Reduction of Cancer Health Disparities (SUCCESS) is conducting a three-arm randomized trial among Hispanic, Haitian, and African American women in Miami-Dade County. Community health workers (CHW) based in each of three communities are recruiting 200 women at each site (600 total). Eligibility criteria include women aged 30-65 years who have not had a Pap smear test in the last 3 years. Prior to randomization, all women undergo a standardized structured interview. Women randomized to public health outreach, Group 1, receive culturally tailored educational materials. Women in Group 2 receive an individualized comprehensive cervical cancer CHW-led education session followed by patient navigation to obtain the Pap smear test at community-based facilities. Women in Group 3 have the option of navigation to a Pap smear test or performing HPV self-sampling. The primary outcome is self-report of completed screening through a Pap smear test or HPV self-sampling within 6 months after enrollment. SUCCESS is one of the first trials testing HPV self-sampling as a screening strategy among underserved minority women. If successful, HPV self-sampling may be an important option in community outreach programs aimed at reducing disparities in cervical cancer. Clinical Trials.gov # NCT02121548, registered April 21, 2014.

  20. Evaluation of the Antimicrobial Activity of Lysostaphin-Coated Hernia Repair Meshes▿

    PubMed Central

    Satishkumar, Rohan; Sankar, Sriram; Yurko, Yuliya; Lincourt, Amy; Shipp, John; Heniford, B. Todd; Vertegel, Alexey

    2011-01-01

    Bacterial infections by antibiotic-resistant Staphylococcus aureus strains are among the most common postoperative complications in surgical hernia repair with synthetic mesh. Surface coating of medical devices/implants using antibacterial peptides and enzymes has recently emerged as a potentially effective method for preventing infections. The objective of this study was to evaluate the in vitro antimicrobial activity of hernia repair meshes coated by the antimicrobial enzyme lysostaphin at different initial concentrations. Lysostaphin was adsorbed on pieces of polypropylene (Ultrapro) mesh with binding yields of ∼10 to 40% at different coating concentrations of between 10 and 500 μg/ml. Leaching of enzyme from the surface of all the samples was studied in 2% (wt/vol) bovine serum albumin in phosphate-buffered saline buffer at 37°C, and it was found that less than 3% of adsorbed enzyme desorbed from the surface after 24 h of incubation. Studies of antibacterial activity against a cell suspension of S. aureus were performed using turbidity assay and demonstrated that the small amount of enzyme leaching from the mesh surface contributes to the lytic activity of the lysostaphin-coated samples. Colony counting data from the broth count (model for bacteria in wound fluid) and wash count (model for colonized bacteria) for the enzyme-coated samples showed significantly decreased numbers of CFU compared to uncoated samples (P < 0.05). A pilot in vivo study showed a dose-dependent efficacy of lysostaphin-coated meshes in a rat model of S. aureus infection. The antimicrobial activity of the lysostaphin-coated meshes suggests that such enzyme-leaching surfaces could be efficient at actively resisting initial bacterial adhesion and preventing subsequent colonization of hernia repair meshes. PMID:21709102

  1. Naturally-Occurring DMSP Analogs as Potential Precursors of Dimethyl Sulfide (DMS) and Methanethiol (MeSH) in Coastal Seawater

    NASA Astrophysics Data System (ADS)

    Cordero, D.; Kiene, R. P.

    2016-02-01

    Dimethylsulfoniopropionate (DMSP) is an osmolyte produced by various macroalgae and phytoplankton in the marine environment. DMSP is known to be the main precursor for dimethyl sulfide (DMS), the major natural sulfur gas emitted from the oceans to the atmosphere. DMS contributes to formation and growth of sulfur-containing aerosols in our stratosphere. These aerosols influence Earth's solar radiation balance and potentially affect the formation of clouds, which could function as a counter-effect to global warming. Bacterioplankton are capable of converting DMSP into DMS via the enzyme DMSP lyase. But not all DMSP in the ocean is converted into DMS. A significant fraction of the DMSP available in the ocean is converted to methanethiol (MeSH) via the bacterial demethylation/demethiolation pathway, with a portion of the MeSH being assimilated as both a carbon and sulfur source. Here we test whether several other naturally-occurring dimethyl sulfonium compounds could be precursors of DMS and MeSH. To test this, we carried out experiments with estuarine water samples from Mobile Bay in the Northern Gulf of Mexico. After collection, unfiltered seawater and seawater filtrate samples, the later containing bacteria only, were treated with 50 nM additions of either 2-dimethylsulfononioacetate (DMSA) or S-Methylmethionine (SMM). After addition of the dimethyl sulfonium compounds, samples were analyzed for sulfur gases with Gas Chromatography-Flame Photometric Detection, using cryogenic-trapping techniques. Addition of DMSA resulted in an immediate increase in MeSH production in both seawater and seawater filtrate containing bacteria only, producing even more MeSH than DMSP. This suggests that DMSA is potentially a significant precursor for MeSH. DMS was not produced in significant amounts from DMSA. Addition of SMM resulted in low rates of both DMS and MeSH accumulation in both seawater samples, indicating that SMM may be a minor precursor for both gases compared to DMSP.

  2. Utility of PCR in diagnosing pulmonary tuberculosis.

    PubMed

    Bennedsen, J; Thomsen, V O; Pfyffer, G E; Funke, G; Feldmann, K; Beneke, A; Jenkins, P A; Hegginbothom, M; Fahr, A; Hengstler, M; Cleator, G; Klapper, P; Wilkins, E G

    1996-06-01

    At present, the rapid diagnosis of pulmonary tuberculosis rests with microscopy. However, this technique is insensitive and many cases of pulmonary tuberculosis cannot be initially confirmed. Nucleic acid amplification techniques are extremely sensitive, but when they are applied to tuberculosis diagnosis, they have given variable results. Investigators at six centers in Europe compared a standardized PCR system (Amplicor; Roche) against conventional culture methods. Defined clinical information was collected. Discrepant samples were retested, and inhibition assays and backup amplification with a separate primer pair were performed. Mycobacterium tuberculosis complex organisms were recovered from 654 (9.1%) of 7,194 samples and 293 (7.8%) of 3,738 patients. Four hundred fifty-two of the M. tuberculosis isolates from 204 patients were smear positive and culture positive. Among the culture-positive specimens, PCR had a sensitivity of 91.4% for smear-positive specimens and 60.9% for smear-negative specimens, with a specificity of 96.1%. Analysis of 254 PCR-positive, culture-negative specimens with discrepant results revealed that 130 were from patients with recently diagnosed tuberculosis and 94 represented a presumed laboratory error. Similar analysis of 118 PCR-negative, culture-positive specimens demonstrated that 27 discrepancies were due to presumed uneven aliquot distribution and 11 were due to presumed laboratory error; PCR inhibitors were detected in 8 specimens. Amplicor enables laboratories with little previous experience with nucleic acid amplification to perform PCR. Disease in more than 60% of the patients with tuberculosis with smear-negative, culture-positive specimens can be diagnosed at the time of admission, and potentially all patients with smear-positive specimens can immediately be confirmed as being infected with M. tuberculosis, leading to improved clinical management.

  3. Extracorporeal shockwave lithotripsy: urine cytology findings.

    PubMed

    Kumar, P V; Salami, K; Tadayyon, A R

    2008-12-01

    To describe the urine cytology findings before and after stone therapy with extracorporeal shock wave lithotripsy (ESWL) and discuss its importance. The study consisted of 100 patients with a urinary tract stone (79 renal pelvic stones and 21 upper ureteric stones), 74 were male and 26 were female. The ages ranged 30-55 years. The average duration of symptoms was 3-8 years. The size of the stones varied from case to case ranging from 10.2 to 40 mm. Urine samples were obtained on three consecutive days before and after lithotripsy. The smears were stained by the Papanicolaou method. The smears before lithotripsy revealed a few red blood cells, inflammatory cells, epithelial cells and crystals (calcium oxalate, uric acid and triple phosphate). Atypical malignant looking cells and epithelial cell clusters were not noticed. After lithotripsy, the urine samples were examined at different periods, 24 hours, 2 weeks, 1 month, 2 months and 3 months. The smears revealed papillary clusters in all 100 patients within 24 hours and were always associated with inflammation. Atypical malignant looking cells appeared later, within 1-2 months in 21 patients, and were associated with inflammation (19 patients), RBC, crystals and papillary clusters. Most of the papillary clusters and atypical malignant looking cells disappeared before 3 months. The epithelial cell clusters and atypical cells were seen in urine smears after ESWL. Without knowing the previous history these findings can be confused with urothelial neoplasms.

  4. Filter Paper-based Nucleic Acid Storage in High-throughput Solid Tumor Genotyping.

    PubMed

    Stachler, Matthew; Jia, Yonghui; Sharaf, Nematullah; Wade, Jacqueline; Longtine, Janina; Garcia, Elizabeth; Sholl, Lynette M

    2015-01-01

    Molecular testing of tumors from formalin-fixed paraffin-embedded (FFPE) tissue blocks is central to clinical practice; however, it requires histology support and increases test turnaround time. Prospective fresh frozen tissue collection requires special handling, additional storage space, and may not be feasible for small specimens. Filter paper-based collection of tumor DNA reduces the need for histology support, requires little storage space, and preserves high-quality nucleic acid. We investigated the performance of tumor smears on filter paper in solid tumor genotyping, as compared with paired FFPE samples. Whatman FTA Micro Card (FTA preps) smears were prepared from 21 fresh tumor samples. A corresponding cytology smear was used to assess tumor cellularity and necrosis. DNA was isolated from FTA preps and FFPE core samples using automated methods and quantified using SYBR green dsDNA detection. Samples were genotyped for 471 mutations on a mass spectrophotometry-based platform (Sequenom). DNA concentrations from FTA preps and FFPE correlated for untreated carcinomas but not for mesenchymal tumors (Spearman σ=0.39 and σ=-0.1, respectively). Average DNA concentrations were lower from FTA preps as compared with FFPE, but DNA quality was higher with less fragmentation. Seventy-six percent of FTA preps and 86% of FFPE samples generated adequate DNA for genotyping. FTA preps tended to perform poorly for collection of DNA from pretreated carcinomas and mesenchymal neoplasms. Of the 16 paired DNA samples that were genotyped, 15 (94%) gave entirely concordant results. Filter paper-based sample preservation is a feasible alternative to FFPE for use in automated, high-throughput genotyping of carcinomas.

  5. Comparative Assessment of Conventional Papanicolaou and Modified Ultrafast Papanicolaou Stains in Fine Needle Aspiration Samples and Body Fluids.

    PubMed

    Arul, P; Eniya, S; Pushparaj, Magesh; Masilamani, Suresh; Kanmani, P; Lingasamy, C

    2018-01-01

    Conventional Papanicolaou (Pap) stain has undergone many modifications; of these, ultrafast Pap stain is the most popular as it shortens the turnaround time of reporting. Application of modified ultrafast Pap (MUFP) stain in the evaluation of fine needle aspiration (FNA) samples and body fluids are scanty. To evaluate the utility of MUFP stain in various FNA samples and body fluids and compare the findings with those of conventional Pap stain. In this cross-sectional study, two wet-fixed and two airdried smears from each sample [301 samples (255 FNA samples and 46 body fluids)] were prepared and stained by the conventional Pap and MUFP stains, respectively. Concordant and discordant rate was calculated. Quality index (QI) of MUFP stain was assessed by background, overall staining, cell morphology, and nuclear characteristics. MUFP-stained smears were also categorized into excellent, good, and fair. The concordance rate for MUFP stain was 100%. QI of MUFP stain for breast, thyroid, lymph node, soft tissue, salivary gland, and body fluids was 0.9, 0.93, 0.95, 1, 0.94, and 1, respectively. Excellent quality of stain was noted in 53.2% and good in 24.6% of the cases allowing easy diagnosis. In 22.2% of fair cases, diagnosis was possible with some difficulties. Our study concluded that MUFP stain could be considered as a rapid and reliable diagnostic tool and can be applied on a regular basis in FNA samples and body fluids to offer immediate diagnosis. However, caution should be taken while reporting certain MUFP-stained smears to avoid over/under diagnosis.

  6. Value of washed sputum gram stain smear and culture for management of lower respiratory tract infections in children.

    PubMed

    Cao, Luong Dong; Ishiwada, Naruhiko; Takeda, Nobue; Nigo, Yukiko; Aizawa, Jirou; Kuroki, Haruo; Kohno, Yoichi

    2004-02-01

    To date, the technique of washed sputum examinations has not been widely used in the clinical management of lower respiratory tract infections in children. A total of 224 sputum samples from 125 pediatric patients with lower respiratory tract infections were collected for washed sputum Gram stain smears and cultures. The results with these methods were compared to find correlation rates. The value of washed sputum cultures was assessed by examining the clinical responses of the patients who received antibiotic therapies instituted on the basis of the sputum culture results. Isolation rates of Haemophilus influenzae, Streptococcus pneumoniae, Moraxella catarrhalis, and Staphylococcus aureus were 22.4%, 9.4%, 4.9%, and 0.4%, respectively. For the prediction of H. influenzae, S. pneumoniae, and M. catarrhalis, the sensitivities of the washed sputum Gram stain smears compared with the culture method were 86.0%, 81.0%, and 90.9%, respectively. The specificities of the washed sputum Gram stain smear technique were 94.8%, 97.5%, and 98.1%, respectively. Overall, the sensitivity and specificity of the washed sputum Gram stain smear method were 85.5% and 87.2%, respectively. S. aureus was isolated from only one specimen; and washed sputum Gram stain smear estimation was correlated with the culture result. On the basis of the washed sputum culture results, appropriate antibiotic therapies were instituted for 93.3% of the patients with acute lower respiratory tract infections. This study suggests that the techniques of washed sputum Gram stain smear and culture are valuable and should be encouraged in clinical practice for the management of lower respiratory tract infections in children.

  7. Cross-sectional studies of tuberculosis prevalence in Cambodia between 2002 and 2011

    PubMed Central

    Mao, Tan Eang; Yamada, Norio; Peou, Satha; Ota, Masaki; Saint, Saly; Kouet, Pichenda; Chea, Manith; Keo, Sokonth; Pheng, Sok Heng; Tieng, Sivanna; Khun, Kim Eam; Sugamoto, Tetsuhiro; Matsumoto, Hiroko; Yoshiyama, Takashi; Ito, Kunihiko; Onozaki, Ikushi

    2014-01-01

    Abstract Objective To measure trends in the pulmonary tuberculosis burden between 2002 and 2011 and to assess the impact of the DOTS (directly observed treatment, short-course) strategy in Cambodia. Methods Cambodia’s first population-based nationwide tuberculosis survey, based on multistage cluster sampling, was conducted in 2002. The second tuberculosis survey, encompassing 62 clusters, followed in 2011. Participants aged 15 years or older were screened for active pulmonary tuberculosis with chest radiography and/or for tuberculosis symptoms. For diagnostic confirmation, sputum smear and culture were conducted on those whose screening results were positive. Findings Of the 40 423 eligible subjects, 37 417 (92.6%) participated in the survey; 103 smear-positive cases and 211 smear-negative, culture-positive cases were identified. The weighted prevalences of smear-positive tuberculosis and bacteriologically-positive tuberculosis were 271 (95% confidence interval, CI: 212–348) and 831 (95% CI: 707–977) per 100 000 population, respectively. Tuberculosis prevalence was higher in men than women and increased with age. A 38% decline in smear-positive tuberculosis (P = 0.0085) was observed with respect to the 2002 survey, after participants were matched by demographic and geographical characteristics. The prevalence of symptomatic, smear-positive tuberculosis decreased by 56% (P = 0.001), whereas the prevalence of asymptomatic, smear-positive tuberculosis decreased by only 7% (P = 0.7249). Conclusion The tuberculosis burden in Cambodia has declined significantly, most probably because of the decentralization of DOTS to health centres. To further reduce the tuberculosis burden in Cambodia, tuberculosis control should be strengthened and should focus on identifying cases without symptoms and in the middle-aged and elderly population. PMID:25177072

  8. Superior Diagnostic Performance of Malaria Rapid Diagnostic Tests as compared to Blood Smears in U.S. Clinical Practice

    PubMed Central

    Stauffer, William M.; Cartwright, Charles P.; Olson, Douglas; Juni, Billie Anne; Taylor, Charlotte M; Bowers, Susan H.; Hanson, Kevan L.; Rosenblatt, Jon E.; Boulware, David R.

    2010-01-01

    Background Approximately 4 million U.S. travelers to developing countries are ill enough to seek healthcare with 1,500 malaria cases reported in the U.S. annually. The diagnosis of malaria is frequently delayed due to the time to prepare malaria blood films and lack of technical expertise. An easy, reliable rapid diagnostic test (RDT) with high sensitivity and negative predictive value (NPV), particularly for Plasmodium falciparum, would be clinically useful. The study objective was to determine the diagnostic performance of the FDA-approved NOW® Malaria Test in comparison to traditional thick and thin blood smears for malaria diagnosis. Methods This prospective study tested 852 consecutive blood samples sent for thick and thin smears with blinded, malaria rapid tests at three hospital laboratories during 2003–2006. Polymerase chain reaction (PCR) verified positive tests and discordant results. Results Malaria occurred in 11% (95/852). The rapid test had superior performance than the standard Giemsa thick blood smear (P=.003). The rapid test’s sensitivity for all malaria was 97% (92/95) vs. 85% (81/95) by blood smear, and the RDT had superior NPV of 99.6% vs. 98.2% (P=.001). The P. falciparum performance was excellent with 100% rapid test sensitivity versus only 88% (65/74) by blood smear (P=.003). Conclusions This operational study demonstrates the FDA-approved rapid malaria test is superior to a single set of blood smears performed under routine U.S. clinical laboratory conditions. The most valuable clinical role of the RDT is in the rapid diagnosis or the exclusion of P. falciparum malaria, which is particularly useful in outpatient settings when evaluating febrile travelers. PMID:19686072

  9. Tuberculosis Laboratory Diagnosis Quality Assurance among Public Health Facilities in West Amhara Region, Ethiopia.

    PubMed

    Shiferaw, Melashu Balew; Hailu, Hiwot Amare; Fola, Abebe Alemu; Derebe, Mulatu Melese; Kebede, Aimro Tadese; Kebede, Abayneh Admas; Emiru, Manamnot Agegne; Gelaw, Zelalem Dessie

    2015-01-01

    Reliable smear microscopy is an important component of Directly Observed Treatment Scheme (DOTS) strategy for TB control program in countries with limited resources. Despite external quality assessment is established in Ethiopia, there is lower TB detection rate (48%) in Amhara region compared to the World Health Organization (WHO) estimate (70%). This highlights the quality of smear microscopy needs to be evaluated. Therefore, the aim of this study was to assess the quality of sputum smear microscopy performance among health center laboratories in West Amhara region, Ethiopia. A cross sectional study was conducted from July 08, 2013 to July 07, 2014. Data were collected from 201 public health center laboratories using a structured questionnaire. Slides were collected based on Lot Quality Assurance Sampling (LQAS) method and rechecked blindly by trained laboratory technologists. The data were entered into EPI info V.7 and smear quality indicators and AFB results were analyzed by SPSS version 20. Among 201 laboratories enrolled in this study, 47 (23.4%) laboratories had major errors. Forty one (20.4%) laboratories had a total of 67 false negative and 29 (14.4%) laboratories had a total of 68 false positive results. Specimen quality, smear thickness and evenness were found poor in 134 (66.7%), 133 (66.2%) and 126 (62.7%) laboratories, respectively. Unavailability of microscope lens cleaning solution (AOR: 2.90; 95% CI: 1.25-6.75; P: 0.013) and dirty smears (AOR: 2.65; 95% CI: 1.14-6.18; P: 0.024) were correlated with false negative results whereas no previous EQA participation (AOR: 3.43; 95% CI: 1. 39-8.45; P: 0.007) was associated with false positive results. The performance of health facilities for sputum smear microscopy was relatively poor in West Amhara region. Hence, strengthening the EQA program and technical support on sputum smear microscopy are recommended to ensure quality tuberculosis diagnostic service.

  10. Evaluation of the Speed-oligo Direct Mycobacterium tuberculosis Assay for Molecular Detection of Mycobacteria in Clinical Respiratory Specimens

    PubMed Central

    Lara-Oya, Ana; Mendoza-Lopez, Pablo; Rodriguez-Granger, Javier; Fernández-Sánchez, Ana María; Bermúdez-Ruiz, María Pilar; Toro-Peinado, Inmaculada; Palop-Borrás, Begoña; Navarro-Marí, Jose María

    2013-01-01

    We present the first evaluation of a novel molecular assay, the Speed-oligo Direct Mycobacterium tuberculosis (SO-DMT) assay, which is based on PCR combined with a dipstick for the detection of mycobacteria and the specific identification of M. tuberculosis complex (MTC) in respiratory specimens. A blind evaluation was carried out in two stages: first, under experimental conditions on convenience samples comprising 20 negative specimens, 44 smear- and culture-positive respiratory specimens, and 11 sputa inoculated with various mycobacterium-related organisms; and second, in the routine workflow of 566 fresh respiratory specimens (4.9% acid-fast bacillus [AFB] smear positives, 7.6% MTC positives, and 1.8% nontuberculous mycobacteria [NTM] culture positives) from two Mycobacterium laboratories. SO-DMT assay showed no reactivity in any of the mycobacterium-free specimens or in those with mycobacterium-related organisms. Compared to culture, the sensitivity in the selected smear-positive specimens was 0.91 (0.92 for MTC and 0.90 for NTM), and there was no molecular detection of NTM in a tuberculosis case or vice versa. With respect to culture and clinical data, the sensitivity, specificity, and positive and negative predictive values for the SO-DMT system in routine specimens were 0.76 (0.93 in smear positives [1.0 for MTC and 0.5 for NTM] and 0.56 in smear negatives [0.68 for MTC and 0.16 for NTM]), 0.99, 0.85 (1.00 in smear positives and 0.68 in smear negatives), and 0.97, respectively. Molecular misidentification of NTM cases occurred when testing 2 gastric aspirates from two children with clinically but not microbiologically confirmed lung tuberculosis. The SO-DMT assay appears to be a fast and easy alternative for detecting mycobacteria and differentiating MTC from NTM in smear-positive respiratory specimens. PMID:23100355

  11. Efficacy of Sodium Hypochlorite Activated With Laser in Intracanal Smear Layer Removal: An SEM Study

    PubMed Central

    Shahriari, Shahriar; Kasraei, Shahin; Roshanaei, Ghodratollah; Karkeabadi, Hamed; Davanloo, Hossein

    2017-01-01

    Introduction: The purpose of the present study was to evaluate the different concentrations of sodium hypochlorite activated with laser in removing of the smear layer in the apical, middle, and coronal segments of root canal walls by scanning electron microscopy analysis. Methods: Sixty single-rooted human mandibular teeth were decoronated to a standardized length. The samples were prepared by using Race rotary system to size 40, 0.04 taper and divided into 4 equal groups (n = 15). Group 1, irrigated with EDTA 17% and 5.25% NaOCl, groups 2, 3 and 4, 1%, 2.5%, and 5% NaOCl activated with Nd:YAG laser, respectively. Teeth were split longitudinally and subjected to scanning electron microscope (SEM). Data were analyzed by Kruskal-Wallis, Mann-Whitney tests. P value of <0.05 was considered statistically significant. Results: Five percent NaOCl LAI (laser-activated irrigation) showed best smear layer removal in test groups and the difference was statistically significant (P < 0.001). Control group (EDTA 17% and 5.25% NaOCl irrigation) showed significantly better outcomes in comparative with test groups (P < 0.001). In the apical third, compared to coronal and middle third, the canal walls were often contaminated by inorganic debris and smear layer. Conclusion: All different concentrations of sodium hypochlorite activated with laser have a positive effect on removing of smear layer. Sodium hypochlorite activated with laser removed smear layer more effectively at the coronal and middle third compared to the apical third. PMID:28912942

  12. Cognitive predictors of cervical cancer screening’s stages of change among sample of Iranian women health volunteers: A path analysis

    PubMed Central

    Miri, Mohammad Reza; Moodi, Mitra; Sharif-Zadeh, Gholam-Reza; Malaki Moghadam, Hakimeh; Miri, Maryam; Norozi, Ensiyeh

    2018-01-01

    Introduction The uptake of Pap smear among Iranian women is low, resulting in a high rate of casualties from cervical cancer in Iran. The present study used the Health Belief Model (HBM) and the Stages of Change theory as theoretical frameworks for understanding the predictors of the behaviour of Iranian Women Health Volunteers (WHVs) with respect to cervical cancer screening. Methods Data from the 1,253 WHVs were analyzed using path analysis to assess the effects of cognitive factors (including knowledge, perceived susceptibility to cervical cancer, perceived severity of cervical cancer, Pap smear benefits, Pap smear barriers, and Pap smear self-efficacy) on the stages of change for Pap-smear behaviour. Results The majority of the respondents (71.5%) reported that they had not taken previous Pap smear tests; only 3% had received a regular Pap test. The perceived benefits to cervical cancer screening, the perceived barriers to cervical cancer screening, and the perceived self-efficacy to perform cervical cancer screening emerged as the predictors of cervical cancer screening’s stages of change; perceived threat to cervical cancer, however, did not. Discussion Uptake of regular cervical screening for Iranian WHVs was very low. Different interventions, such as media campaigns and educational interventions could provide an opportunity to improve women's knowledge on cervical cancer and Pap test benefits, address any misconceptions or fears about the procedure of the Pap test, and finally increase the cervical screening uptake by Iranian women. PMID:29558488

  13. The effect of health education on the knowledge, attitude, and uptake of free Pap smear among female teachers in Birnin-Kebbi, North-Western Nigeria.

    PubMed

    Adamu, A N; Abiola, A O; Ibrahim, Mto

    2012-01-01

    The Routine Pap smear test has successfully reduced the incidence of invasive cervical cancer in the presence of a proper structure for its implementation. This study was designed to assess the effect of health education on the knowledge, attitude, and uptake of Pap smear among female teachers. It was a quasi-experimental, controlled study with a pre-test, post-test design. A total of 100 respondents were recruited for each of the intervention and control groups, by the multistage sampling technique. The mean knowledge score of cervical cancer was low in both the interventions (25.5% ± 10.5) and control groups (18.9% ± 10.0) at baseline; a significant rise to 57.2% ± 20.7 was recorded after the intervention in the Intervention group (P<0.0001). The baseline mean attitude score was also low in the intervention and control groups (17.1% ± 6.3 and 14.1% ± 6.4, respectively); post intervention there was a significant rise of up to 28.0% ± 12.8 in the Intervention group (P<0.0001). The proportion of respondents with a reported practice of Pap smear was low and similar in both the groups at baseline (1.1 and 4.9% in the intervention and control groups, respectively, P=0.16). Uptake of free Pap smear was poor at the post-intervention phase in both the groups (P=0.45). Reported reasons for poor uptake included the respondents' dislike for the test (38.4%) and the belief that the test was not necessary (24.4%). About 20% of the respondents did not have any reason at all. Health education had no significant effect on the uptake of a free Pap smear among teachers. Despite the significant improvement in the attitude toward the test, many respondents did not like the test after than before the intervention. Sociocultural issues such as the gender of the sample collector, and system factors like few service delivery points, and the time required to access the service could have contributed to the poor uptake recorded in this study. A program designed to improve routine cervical cancer screening by Pap smear should therefore address not only the knowledge and cost, but also the sociocultural and systemic factors.

  14. Comparison of Pap smear quality with anatomical spatula and convenience (spatula-cytobrush) methods: a single blind clinical trial.

    PubMed

    Abdali, Khadijeh; Soleimani, Marzieh; Khajehei, Marjan; Tabatabaee, Hamid Reza; Komar, Perikala V; Montazer, Nader Riaz

    2010-01-01

    The Papanicolaou smear is a standard test for cervical cancer screening; however, the most important challenge is high false negative results. Several factors contribute to this problem and one the most important is inappropriate sampling. The aim of this study was to compare the quality of smears obtained by either an anatomical spatula or a spatula-cyto brush. One hundred married women participated in this single blind clinical trial. After all participants were interviewed, two samples were obtained from each: one with a spatula-cytobrush and another with an anatomical spatula. Slides were prepared and assessed by two pathologists for kappa coefficient analysis. Cell adequacy was 96.1 % in anatomical spatula method and 91.2 % in spatula-cyto brush method (p= 0.016). The rates for endocervical cells and metaplasia cells were 70.6%and 24.5%, respectively, with the anatomical spatula method and 69.6% and 24.5% using a spatula-cytobrush (p<0.001). No one reported pain and the amount of bleeding was 38.2% in both methods (p>0.05). In addition, there were no statistically significant differences regarding infection and inflammatory reactions (p>0.05). Based on the findings of this study, the results of sampling with anatomical spatula were more acceptable and better than those of spatula-cytobrush sampling.

  15. Measured reflectance suppressed by thin-film interference of crude oil smeared on glass - as on vitrinite in coal or petroliferous rocks

    USGS Publications Warehouse

    Bostick, Neely

    2011-01-01

    The tool of measuring "vitrinite reflectance" under a microscope has great value in petroleum exploration and coal utilization, and the reflectance is a simple number, such as 1.4% Ro, with some slight variations depending on technique. Sample collection, preparation and measurement are simple and many sedimentary rocks yield vitrinite. However, the reported number can lead one astray if its origin and quality are not fully understood. I analyze here just one factor, "smear" of crude oil on the polished surface (from the sample), which may reduce reflectance because of thin-film interference. Some other causes of error are listed in an addendum to this note.

  16. Pap smear cytology and identification of Human Papillomavirus (HPV) type 16 and 18 in multiparity women at Aviati Clinic Padang Bulan Medan

    NASA Astrophysics Data System (ADS)

    Anggraini, D. R.; Feriyawati, L.; Fitrie, A. A.; Ginting, R. N. A.

    2018-03-01

    Cervical cancer is the second most frequent cancer in woman in developing countries and one of the most crucial health problems in the world. Human Papillomavirus (HPV) is an agent for sexually transmitted disease which is an act of cervical cancer, especially high-risk of HPV type 16 and 18. In this study, we investigated the Pap smear cytology features and identification of HPV types 16 and18 in multiparity women at Aviati Clinic Padang Bulan, Medan. Samples are cervical swabs of 50 multiparity women who met the inclusion criteria (childbirth ≥ three times) was included in the study. Pap smear examination was conducted using Papanicolaou staining and identification of HPV types 16 and 18 using the Polymerase Chain Reactive (PCR) methods. Pap smearcytology showed 80% Negative for intraepithelial lesion or malignancy (NILM) with inflammation and 20% NILM. The result of PCR amplification showed that there weren’t specific band DNA was found at band 414bp and 216bp. That means there weren’t cervical swabs sample had DNA of HPV type 16 and 18.

  17. Detection of enteropathogens associated with travelers' diarrhea using a multiplex Luminex-based assay performed on stool samples smeared on Whatman FTA Elute cards.

    PubMed

    Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R

    2015-09-01

    We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman(™) FTA Elute cards smeared with stool containing pathogens associated with travelers' diarrhea. LoDs ranged from 10(2) to 10(5)CFU, PFU, or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoDs increased with prolonged storage of cards. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. A discontinuous Galerkin method with a bound preserving limiter for the advection of non-diffusive fields in solid Earth geodynamics

    NASA Astrophysics Data System (ADS)

    He, Ying; Puckett, Elbridge Gerry; Billen, Magali I.

    2017-02-01

    Mineral composition has a strong effect on the properties of rocks and is an essentially non-diffusive property in the context of large-scale mantle convection. Due to the non-diffusive nature and the origin of compositionally distinct regions in the Earth the boundaries between distinct regions can be nearly discontinuous. While there are different methods for tracking rock composition in numerical simulations of mantle convection, one must consider trade-offs between computational cost, accuracy or ease of implementation when choosing an appropriate method. Existing methods can be computationally expensive, cause over-/undershoots, smear sharp boundaries, or are not easily adapted to tracking multiple compositional fields. Here we present a Discontinuous Galerkin method with a bound preserving limiter (abbreviated as DG-BP) using a second order Runge-Kutta, strong stability-preserving time discretization method for the advection of non-diffusive fields. First, we show that the method is bound-preserving for a point-wise divergence free flow (e.g., a prescribed circular flow in a box). However, using standard adaptive mesh refinement (AMR) there is an over-shoot error (2%) because the cell average is not preserved during mesh coarsening. The effectiveness of the algorithm for convection-dominated flows is demonstrated using the falling box problem. We find that the DG-BP method maintains sharper compositional boundaries (3-5 elements) as compared to an artificial entropy-viscosity method (6-15 elements), although the over-/undershoot errors are similar. When used with AMR the DG-BP method results in fewer degrees of freedom due to smaller regions of mesh refinement in the neighborhood of the discontinuity. However, using Taylor-Hood elements and a uniform mesh there is an over-/undershoot error on the order of 0.0001%, but this error increases to 0.01-0.10% when using AMR. Therefore, for research problems in which a continuous field method is desired the DG-BP method can provide improved tracking of sharp compositional boundaries. For applications in which strict bound-preserving behavior is desired, use of an element that provides a divergence-free condition on the weak formulation (e.g., Raviart-Thomas) and an improved mesh coarsening scheme for the AMR are required.

  19. qPCR detection of Mycobacterium leprae in biopsies and slit skin smear of different leprosy clinical forms.

    PubMed

    Azevedo, Michelle de Campos Soriani; Ramuno, Natália Mortari; Fachin, Luciana Raquel Vincenzi; Tassa, Mônica; Rosa, Patrícia Sammarco; Belone, Andrea de Faria Fernandes; Diório, Suzana Madeira; Soares, Cleverson Teixeira; Garlet, Gustavo Pompermaier; Trombone, Ana Paula Favaro

    Leprosy, whose etiological agent is Mycobacterium leprae, is a chronic infectious disease that mainly affects the skin and peripheral nervous system. The diagnosis of leprosy is based on clinical evaluation, whereas histopathological analysis and bacilloscopy are complementary diagnostic tools. Quantitative PCR (qPCR), a current useful tool for diagnosis of infectious diseases, has been used to detect several pathogens including Mycobacterium leprae. The validation of this technique in a robust set of samples comprising the different clinical forms of leprosy is still necessary. Thus, in this study samples from 126 skin biopsies (collected from patients on all clinical forms and reactional states of leprosy) and 25 slit skin smear of leprosy patients were comparatively analyzed by qPCR (performed with primers for the RLEP region of M. leprae DNA) and routine bacilloscopy performed in histological sections or in slit skin smear. Considering clinical diagnostic as the gold standard, 84.9% of the leprosy patients were qPCR positive in skin biopsies, resulting in 84.92% sensitivity, with 84.92 and 61.22% positive (PPV) and negative (NPV) predictive values, respectively. Concerning bacilloscopy of histological sections (BI/H), the sensitivity was 80.15% and the PPV and NPV were 80.15 and 44.44%, respectively. The concordance between qPCR and BI/H was 87.30%. Regarding the slit skin smear, 84% of the samples tested positive in the qPCR. Additionally, qPCR showed 100% specificity, since all samples from different mycobacteria, from healthy individuals, and from other granulomatous diseases presented negative results. In conclusion, the qPCR technique for detection of M. leprae using RLEP primers proved to be specific and sensitive, and qPCR can be used as a complementary test to diagnose leprosy irrespective of the clinical form of disease. Copyright © 2016 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.

  20. The effect of anchovy substrate application to fluor retention rate on Sprague Dawley rat tooth email (in vivo)

    NASA Astrophysics Data System (ADS)

    Zabrina, S.; Puspitawati, R.; Gunawan, H. A.

    2017-08-01

    Usage of anchovies (Stolephorus insularis), which contain a high fluoride concentration in a CaF2 compound, needs to be examined as a topical fluoridative agent. Aim: To study the effects of an anchovy substrate application, either by chewing or smearing, in increasing fluoride retention of enamel. Fourteen Sprague Dawley rats were divided into five groups: baseline, experimental (feeding and smearing), and negative controls. After 15 days, lower incisor teeth were extracted and fluoride retention on the enamel surface was measured using EDX. Data were analyzed by the independent samples t-test, the Mann-Whitney U test, and the Kruskal-Wallis test. There was a significant increase in fluoride retention on enamel from the experimental groups compared to the negative control group (p < 0.05). Fluoride retention levels of the experimental feeding group (6.823%) were slightly higher than those of the experimental smearing group (6.783%), though the difference was not statistically significant (p < 0.05). Anchovy substrate application, either by chewing or smearing, increases fluoride retention on tooth enamel.

  1. Comparison of skin smears and biopsy specimens for demonstration of Leishmania tropica bodies in cutaneous leishmaniasis.

    PubMed

    Dar, Nasser Rashid; Khurshid, Tariq

    2005-12-01

    To determine and compare the diagnostic value of skin biopsy, saline aspirate smears, skin slit smears and skin biopsy impression smears to demonstrate Leishmania tropica (LT) bodies in cutaneous leishmaniasis and to determine any association within the applied diagnostic tests. An analytical study. Department of Dermatology, PNS Shifa, Karachi from January to December 2003. Seventyeight patients of cutaneous leishmaniasis were subjected to saline aspirate smears, skin slit smears, skin biopsy impression smears and skin biopsy and looked for LT bodies. The percentage positivity of all methods was calculated. McNemar test was applied to determine the association between percentage positivities of methods. Skin biopsy showed LT bodies in 70 (89.74%) patients, saline aspirate smears in 24 (30.76%), skin slit smears in 25 (32.05%) and skin biopsy impression smears in 27 (34.61%) patients. Smears demonstrated LT bodies in 10.25% cases in which biopsy was negative. Skin biopsy impression smears showed concordant results with skin biopsy in 20.51%, skin slit smears in 16.66% and saline aspirate smears in 19.25% of cases. Saline aspirate smears were positive in 48.1% of cases in which biopsy impression smears were negative, slit smears were positive in 50.9 % of cases in which biopsy impression smears were negative and slit smears were positive in 37% of cases in which saline aspirate smears were negative. Skin biopsy for histopathology is the most useful method in the demonstration of Leishmania parasite. Sensitivity of smears can be increased by a combination of various skin smears.

  2. Does neutralization of gastric aspirates from children with suspected intrathoracic tuberculosis affect mycobacterial yields on MGIT culture?

    PubMed

    Parashar, Deepak; Kabra, Sushil K; Lodha, Rakesh; Singh, Varinder; Mukherjee, Aparna; Arya, Tina; Grewal, Harleen M S; Singh, Sarman

    2013-06-01

    The microbiological confirmation of pulmonary tuberculosis in children relies on cultures of gastric aspirate (GA) specimens. Conventionally, GAs are neutralized to improve culture yields of mycobacteria. However, there are limited data to support this practice. To study the utility of neutralization of GAs with sodium bicarbonate in children with intrathoracic tuberculosis, a total of 116 children of either sex, aged 6 months to 14 years (median age, 120 months; interquartile range [IQR], 7 to 192 months), underwent gastric aspiration on 2 consecutive days. Gastric aspirates were divided into two aliquots, and only one aliquot was neutralized with 1% sodium bicarbonate. Both aliquots were processed for smear and culture examinations. Out of the 232 gastric aspirates, 12 (5.17%) were acid-fast bacilli (AFB) smear positive. There were no differences in smear positivity rates from samples with or without neutralization. The yield of Mycobacterium tuberculosis on a Bactec MGIT 960 culture system was significantly lower in the neutralized samples (16.3% [38/232]) than in the nonneutralized samples (21.5% [50/232]) (P = 0.023). There was no significant difference between the neutralized and the nonneutralized samples in time to detection using the MGIT 960 system (average, 24.6 days; IQR, 12 to 37 days) (P = 0.9). The contamination rates were significantly higher in the neutralized samples than in the nonneutralized samples (17.2% [40/232] versus 3.9% [9/232]) (P = 0.001). The agreement for positive mycobacterial culture between the two approaches was 66.5% (P = 0.001). Hence, we recommend that gastric aspirate samples not be neutralized with sodium bicarbonate prior to culture for M. tuberculosis.

  3. Trends and anomalies in gas evolution from coal samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vorres, K.S.

    1993-09-01

    As part of the stability studies on these sealed samples a number of the samples were given to the Analytical Chemistry Laboratory at ANL for periodic gas analysis. 1. Higher rank coals evolve methane, and lower rank coals evolve carbon dioxide with some evolution of both gases for the intermediate ranks. 2. The evolution proceeds over times of years for pulverized coals in sealed ampules. 3. Gas concentrations are higher above -20 mesh samples than above -100 mesh material. 4. Carbon monoxide is not evolved.

  4. Induced sputum and bronchoscopy in the diagnosis of pulmonary tuberculosis

    PubMed Central

    McWilliams, T; Wells, A; Harrison, A; Lindstrom, S; Cameron, R; Foskin, E

    2002-01-01

    Background: Previous studies suggest that bronchoscopy and a single induced sputum sample are equally effective for diagnosing pulmonary tuberculosis. Methods: In a prospective study of subjects with possibly active pulmonary tuberculosis, the diagnostic yield of three induced sputum tests was compared with that of bronchoscopy. Subjects either produced no sputum or (acid fast) smear negative sputum. Bronchoscopy was only performed if at least two induced sputum samples were smear negative. Results: Of 129 subjects who completed all tests, 27 (21%) had smear negative and culture positive specimens, 14 (52%) on bronchoscopy and 26 (96%) on induced sputum (p<0.005). One patient was culture positive on bronchoscopy alone compared with 13 on induced sputum alone; 13 were culture positive on both tests. Induced sputum positivity was strikingly more prevalent when chest radiographic appearances showed any features of active tuberculosis (20/63, 32%) than when appearances suggested inactivity (1/44, 2%; p<0.005). Induced sputum costs were about one third those of bronchoscopy, and the ratio of costs of the two tests per case of tuberculosis diagnosed could be as much as 1:6. Conclusions: In subjects investigated for possibly active or inactive tuberculosis who produce no sputum or have smear negative sputum, the most cost effective strategy is to perform three induced sputum tests without bronchoscopy. Induced sputum testing carries a high risk of nosocomial tuberculosis unless performed in respiratory isolation conditions. The cost benefits shown could be lost if risk management measures are not observed. PMID:12454293

  5. Inuit women's attitudes and experiences towards cervical cancer and prevention strategies in Nunavik, Quebec.

    PubMed

    Cerigo, Helen; Macdonald, Mary Ellen; Franco, Eduardo L; Brassard, Paul

    2012-03-19

    To describe the attitudes about and experiences with cervical cancer, Pap smear screenings and the HPV vaccine among a sample of Inuit women from Nunavik, Quebec, Canada. We also evaluated demographic and social predictors of maternal interest in HPV vaccination. A mixed method design was used with a cross-sectional survey and focus group interviews. Women were recruited through convenience sampling at 2 recruitment sites in Nunavik from March 2008 to June 2009. Differences in women's responses by age, education, and marital status were assessed. Unconditional logistic regression was used to determine predictors of women's interest in HPV vaccination for their children. Questionnaires were completed by 175 women aged 18-63, and of these women a total of 6 women aged 31-55 participated in 2 focus groups. Almost half the survey participants had heard of cervical cancer. Women often reported feelings of embarrassment and pain during the Pap smear and older women were more likely to feel embarrassed than younger women. Only 27% of women had heard of the HPV vaccine, and 72% of these women were interested in vaccinating their child for HPV. No statistically significant predictors of maternal interest in HPV vaccination were found. Our findings indicate that health service planners and providers in Nunavik should be aware of potential barriers to Pap smear attendance, especially in the older age groups. Given the low awareness of cervical cancer, the Pap smear and the HPV vaccine, education on cervical cancer and prevention strategies may be beneficial.

  6. Laboratory hydraulic calibration of the Helley-Smith bedload sediment sampler

    USGS Publications Warehouse

    Druffel, Leroy; Emmett, W.W.; Schneider, V.R.; Skinner, J.V.

    1976-01-01

    Filling the sample bag to 40 percent capacity with a sediment larger in diameter than the mesh size of the bag had no effect on the hydraulic efficiency. Particles close to the 0.2 mm mesh size of the sample bag plugged the openings and caused the efficiency to decrease in an undetermined manner.

  7. Effect of smear layer thickness and pH of self-adhesive resin cements on the shear bond strength to dentin.

    PubMed

    Ebrahimi Chaharom, Mohammad Esmaeel; Ajami, Amir Ahmad; Bahari, Mahmoud; Rezazadeh, Haleh

    2017-01-01

    There are concerns in relation to the bonding efficacy of self-adhesive resin cements to dentin covered with the smear layer. This study aims to evaluate the effect of smear layer thickness and different pH values of self-adhesive resin cements on the shear bond strength to dentin. The dentin on the buccal and lingual surfaces of 48 sound human premolars were abraded with 60- and 600-grit silicon carbide papers to achieve thick and thin smear layers, respectively. The samples were divided into three groups (n = 16) based on the cement pH: Rely-X Unicem (RXU) (pH < 2); Clearfil SA Luting (CSL) (pH = 3); and Speed CEM (SPC) (pH = 4.5). In each group, composite resin blocks were bonded to the buccal and lingual surfaces. After 24 h, the shear bond strength values were measured in MPa, and the failure modes were evaluated under a stereomicroscope. Data were analyzed with two-way ANOVA and post hoc least significant difference tests (P < 0.05). Cement pH had a significant effect on the shear bond strength (P = 0.02); however, the smear layer thickness had no significant effect on the shear bond strength (P > 0.05). The cumulative effect of these variables was not significant, either (P = 0.11). The shear bond strengths of SPC and CSL self-adhesive resin cements were similar and significantly lower than that of RXU. The smear layer thickness was not a determining factor for the shear bond strength value of self-adhesive resin cements.

  8. [Assessment of a rapid diagnostic test and portable fluorescent microscopy for malaria diagnosis in Cotonou (Bénin)].

    PubMed

    Ogouyèmi-Hounto, A; Kinde-Gazard, D; Keke, C; Gonçalves, E; Alapini, N; Adjovi, F; Adisso, L; Bossou, C; Denon, Y V; Massougbodji, A

    2013-02-01

    The aim of the study was to determine the accuracy of a rapid diagnostic test (SD Bioline Malaria Ag P.f/ Pan®) and fluorescent microscopy (CyScope®) in confirming presumptive malaria diagnosis in Cotonou. Thick blood smear was used as the reference technique for comparison. Testing was conducted on persons between the ages of 6 months and 70 years at two hospitals from June to October 2010. If malaria was suspected in the sample by the nurse based on clinical findings and sent to laboratory for confirmation, one thick smear, one rapid diagnostic test and one slide for the fluorescent microscopy were performed. All tests were read in hospital laboratories involved with the quality control of thick blood smear in the parasitology laboratory of National University Hospital of Cotonou. A total of 354 patients with clinical diagnosis of malaria were included. Malaria prevalence determined by thick smear, rapid diagnostic test and fluorescent microscopy was 22.8%, 25.4%, and 25.1% respectively. The sensitivity, specificity, positive and negative predictive values compared to the thick smears were 96.3, 95.6, 86.7, and 98.9% for rapid diagnostic test; and 97.5, 96.7, 89.8, and 99.27% for fluorescent microscopy. With these performances, these tests meet acceptability standards recommended by WHO for rapid tests (sensitivity > 95%). These two methods have advantages for the confirmation of malaria diagnosis in peripheral health structures that lack the resources to conduct diagnosis confirmation by the thick blood smear.

  9. The influence of material and mesh characteristics on transmission mode desorption electrospray ionization.

    PubMed

    Chipuk, Joseph E; Brodbelt, Jennifer S

    2009-04-01

    Adaptation of desorption electrospray ionization to a transmission mode (TM-DESI) entails passing an electrospray plume through a sample that has been deposited onto a mesh substrate. A combination of mass spectrometry and fluorescence microscopy studies is used to illustrate the critical role material composition, mesh open space, and mesh fiber diameter play on the transmission, desorption, and ionization process. Substrates with open spaces less than 150 microm and accompanying minimal strand diameters produce less scattering of the plume and therefore favor transmission. Larger strand diameters typically encompass larger open spaces, but the increase in the surface area of the strand increases plume scattering as well as solvent and analyte spreading on the mesh. Polypropylene (PP), ethylene tetrafluoroethylene (ETFE), and polyetheretherketone (PEEK) materials afford much better desorption than similarly sized polyethylene terephthalate (PETE) or nylon-6,6 (PA66) substrates. Ultimately, the manner in which the electrospray plume interacts with the mesh as it is transmitted through the substrate is shown to be critical to performing and optimizing TM-DESI analyses. In addition, evidence is presented for analyte dependent variations in the desorption mechanisms of dry and solvated samples.

  10. Effectiveness of Three Different Irrigants - 17% Ethylenediaminetetraacetic Acid, Q-MIX, and Phytic Acid in Smear Layer Removal: A Comparative Scanning Electron Microscope Study.

    PubMed

    Jagzap, Janhavi Balasaheb; Patil, Sanjay S; Gade, Vandana Jaykumar; Chandhok, Deepika J; Upagade, Madhura A; Thakur, Deepa A

    2017-01-01

    Removal of smear layer from the root canal walls is important for long-standing endodontic success. The aim of this study is to evaluate and compare smear layer removing ability among 17% ethylenediaminetetraacetic acid (EDTA), Q-MIX, and phytic acid by scanning electron microscopy (SEM). This in-vitro experimental study assessed smear layer removal using three different irrigants. Thirty single-rooted freshly extracted human permanent premolars were collected, disinfected, and decoronated to a standardized root length of 13 mm. Root canals were cleaned and shaped till F2 universal rotary protaper at working length 1 mm short of the apex. They were randomly divided into three groups, and final irrigation was done accordingly. Group 1 ( n = 10): with 1 ml of 17% EDTA, Group 2 ( n = 10): with 1 ml of Q-MIX, Group 3 ( n = 10): with 1 ml of phytic acid. Samples were then longitudinally sectioned and evaluated under SEM at coronal, middle, and apical levels. Two-way analysis of variance and Tukey's post hoc test were performed. The level of significance was set at 0.05. Smear layer removing ability among irrigants and sections in descending order: 17 EDTA > Q-MIX > phytic acid; coronal > middle > apical. 17% EDTA showed better and promising results followed by Q-MIX and then phytic acid.

  11. Sputum smear microscopy: evaluation of impact of training, microscope distribution, and use of external quality assessment guidelines for resource-poor settings.

    PubMed

    Van Rie, A; Fitzgerald, D; Kabuya, G; Van Deun, A; Tabala, M; Jarret, N; Behets, F; Bahati, E

    2008-03-01

    Sputum smear microscopy is the main and often only laboratory technique used for the diagnosis of tuberculosis in resource-poor countries, making quality assurance (QA) of smear microscopy an important activity. We evaluated the effects of a 5-day refresher training course for laboratory technicians and the distribution of new microscopes on the quality of smear microscopy in 13 primary health care laboratories in Kinshasa, Democratic Republic of Congo. The 2002 external QA guidelines for acid-fast bacillus smear microscopy were implemented, and blinded rechecking of the slides was performed before and 9 months after the training course and microscope distribution. We observed that the on-site checklist was highly time-consuming but could be tailored to capture frequent problems. Random blinded rechecking by the lot QA system method decreased the number of slides to be reviewed. Most laboratories needed further investigation for possible unacceptable performance, even according to the least-stringent interpretation. We conclude that the 2002 external QA guidelines are feasible for implementation in resource-poor settings, that the efficiency of external QA can be increased by selecting sample size parameters and interpretation criteria that take into account the local working conditions, and that greater attention should be paid to the provision of timely feedback and correction of the causes of substandard performance at poorly performing laboratories.

  12. Sputum smear examination and time to diagnosis in patients with smear-negative pulmonary tuberculosis in the Pacific.

    PubMed

    Viney, K; Bissell, K; Tabutoa, K; Kienene, T; Linh, N N; Briand, K; Harries, A D

    2012-12-21

    National tuberculosis programmes (NTPs) in Kiribati and the Marshall Islands, 2006-2010. To determine the proportion of all tuberculosis (TB) cases that were pulmonary smear-negative, and for these patients to determine how many sputum smears were examined and the time from sputum smear examination to registration. A retrospective cross-sectional study involving a record review of national TB and laboratory registers. Of 2420 TB cases identified, 709 (29%) were registered as smear-negative pulmonary TB. Of the 695 (98%) with information on smear examination, 222 (32%) had no smear recorded, 61 (9%) had one smear, 86 (12%) two smears and 326 (47%) three smears. Among the 473 patients who had at least one smear, 238 (50%) were registered before sputum examination, 131 (28%) within 1 week, 72 (15%) between 1 and 4 weeks, and 34 (7%) >4 weeks after sputum examination. NTPs in Kiribati and the Marshall Islands are diagnosing 29% of all TB patients as smear-negative pulmonary TB. Many patients do not have smears done or are registered before undergoing smear examination. Corrective measures are needed.

  13. Comparison of PCR-Based Diagnosis with Centrifuged-Based Enrichment Method for Detection of Borrelia persica in Animal Blood Samples.

    PubMed

    Naddaf, S R; Kishdehi, M; Siavashi, Mr

    2011-01-01

    The mainstay of diagnosis of relapsing fever (RF) is demonstration of the spirochetes in Giemsa-stained thick blood smears, but during non fever periods the bacteria are very scanty and rarely detected in blood smears by microscopy. This study is aimed to evaluate the sensitivity of different methods developed for detection of low-grade spirochetemia. Animal blood samples with low degrees of spirochetemia were tested with two PCRs and a nested PCR targeting flaB, GlpQ, and rrs genes. Also, a centrifuged-based enrichment method and Giemsa staining were performed on blood samples with various degrees of spirochetemia. The flaB-PCR and nested rrs-PCR turned positive with various degrees of spirochetemia including the blood samples that turned negative with dark-field microscopy. The GlpQ-PCR was positive as far as at least one spirochete was seen in 5-10 microscopic fields. The sensitivity of GlpQ-PCR increased when DNA from Buffy Coat Layer (BCL) was used as template. The centrifuged-based enrichment method turned positive with as low concentration as 50 bacteria/ml blood, while Giemsa thick staining detected bacteria with concentrations ≥ 25000 bacteria/ml. Centrifuged-based enrichment method appeared as much as 500-fold more sensitive than thick smears, which makes it even superior to some PCR assays. Due to simplicity and minimal laboratory requirements, this method can be considered a valuable tool for diagnosis of RF in rural health centers.

  14. Occurrence of filaria in domestic dogs of Samburu pastoralists in Northern Kenya and its associations with canine distemper.

    PubMed

    Albrechtová, Kateřina; Sedlák, Kamil; Petrželková, Klára J; Hlaváč, Jan; Mihalca, Andrei D; Lesingirian, Alison; Kanyari, Paul W N; Modrý, David

    2011-12-15

    Samples of blood (serum, smears and blood preserved with ethanol) were collected from dogs during a vaccination campaign in northern Kenya in the years 2006 and 2007. Blood was screened for filarial parasites using molecular and microscopy methods and sera were tested for antibodies against canine distemper virus (CDV). Parasitological examination revealed the presence of two species of canine filariae: Acanthocheilonema dracunculoides and A. reconditum. The DNA from the former species was detected in 58% dogs sampled in 2006 and 36% dogs sampled in 2007, whereas the latter was found only in 4.2% samples collected in 2007. Microfilariae were found in 33.8% blood smears collected in 2006 and 10.6% blood smears collected in 2007. The seroprevalence of CDV was 33.4% in 2006 and 11.2% in 2007. The effect of sex, age and CDV-seropositivity/seronegativity on the occurrence of A. dracunculoides was evaluated. Infection by A. dracunculoides was more common in males and in dogs with a positive antibody titer for canine distemper, but evenly distributed among different age groups. The difference in the prevalence of A. dracunculoides in two isolated mountain ranges was not statistically significant. Methodologies available for detection and determination of canine filariae are compared, underlining methodical pitfalls arising through the determination of less common filarial species. The role of single epidemiological factors and possible association between canine distemper and filariasis are discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Albendazole Stimulates the Excretion of Strongyloides stercoralis Larvae in Stool Specimens and Enhances Sensitivity for Diagnosis of Strongyloidiasis▿

    PubMed Central

    Anamnart, Witthaya; Pattanawongsa, Attarat; Intapan, Pewpan Maleewong; Maleewong, Wanchai

    2010-01-01

    We succeeded in stimulation of excretion of Strongyloides stercoralis larvae in stool by oral administration of a single dose of 400 mg albendazole to strongyloidiasis patients. This result overcame the false-negative results of stool examination due to low larval numbers. Stool samples were collected from 152 asymptomatic strongyloidiasis patients in the morning, prior to eating. After breakfast, they were given a dose of 400 mg albendazole, and stool samples were collected the following morning. Agar plate culture (APC), modified formalin-ether concentration technique (MFECT), and direct-smear (DS) methods were used to examine stool specimens within 3 h after defecation. The results before and after albendazole was taken were compared. All APCs that were positive became negative after albendazole administration, while MFECT showed a 1.4- to 18.0-fold increase in larval numbers in 97.4% (148/152) of the samples. The DSs were positive in 3 out of 3 smears at a larval number of ≥45 larvae per g (lpg) of stool, and in 1or 2 out of 3 smears at a larval number between 35 and 44 lpg. At a larval number of <35 lpg, the DS became negative. Interestingly 90.5% (19/21) of the samples that were negative by all methods before albendazole administration became positive by MFECT after the treatment. Thus, MFECT can be effectively used for diagnosis of strongyloidiasis with prior administration of albendazole to the subject. PMID:20844212

  16. Prevalence of Abnormal Papanicolaou Test Results and Related Factors among Women Living in Zanjan, Iran.

    PubMed

    Maleki, Azam; Ahmadnia, Elahe; Avazeh, Azar; Mazloomzadeh, Saeideh; Molaei, Behnaz; Jalilvand, Ahmad

    2015-01-01

    Currently, a comprehensive program for screening and early detection of cervical cancer does not exist in Iran. This study aimed to determine the prevalence of abnormal Papanicolaou (Pap) smears and some related factors among women living in Zanjan, Iran. This cross-sectional study was conducted in 2012 in Zanjan on 4274 married women aged 20-65 years. The study participants were selected through two-stage cluster sampling. After obtaining written consent, demographic and fertility questionnaires were completed. Samples from cervix were obtained through a standard method using the Rover Cervex- Brush. Evaluation and interpretation of the samples were reported using the Bethesda 2001 method. Data were statistically analyzed using chi-square and logistic regression models. Most inflammatory changes in the samples were mild (37.4%). Abnormal atypical changes in the epithelial cells were found in 4.04%. The highest percentage of abnormal changes in the epithelial cells was atypical squamous cells of undetermined significance (ASCUS) (1.9%). Abnormal results of Pap smear was significantly and independently associated with age, papillomavirus infection, and lack of awareness about Pap smear tests. Given the high prevalence of inflammatory and precancerous changes in this study, compared to other studies in Iran and other Muslim countries, and the effect of demographic variables and individual factors on abnormal results, increasing the awareness of women and their families regarding the risk factors for cervical cancer, preventive measures such as screening, and timely treatment seem necessary.

  17. Diagnostic performance of smear microscopy and incremental yield of Xpert in detection of pulmonary tuberculosis in Rwanda.

    PubMed

    Ngabonziza, Jean Claude Semuto; Ssengooba, Willy; Mutua, Florence; Torrea, Gabriela; Dushime, Augustin; Gasana, Michel; Andre, Emmanuel; Uwamungu, Schifra; Nyaruhirira, Alaine Umubyeyi; Mwaengo, Dufton; Muvunyi, Claude Mambo

    2016-11-08

    Tuberculosis control program of Rwanda is currently phasing in light emitting diode-fluorescent microscopy (LED-FM) as an alternative to Ziehl-Neelsen (ZN) smear microscopy. This, alongside the newly introduced Xpert (Cepheid, Sunnyvale, CA, USA) is expected to improve diagnosis of tuberculosis and detection of rifampicin resistance in patients at health facilities. We assessed the accuracy of smear microscopy and the incremental sensitivity of Xpert at tuberculosis laboratories in Rwanda. This was a cross-sectional study involving four laboratories performing ZN and four laboratories performing LED-FM microscopy. The laboratories include four intermediate (ILs) and four peripheral (PLs) laboratories. After smear microscopy, the left-over of samples, of a single early-morning sputum from 648 participants, were tested using Xpert and mycobacterial culture as a reference standard. Sensitivity of each test was compared and the incremental sensitivity of Xpert after a negative smear was assessed. A total of 96 presumptive pulmonary tuberculosis participants were culture positive for M. tuberculosis. The overall sensitivity in PL of ZN was 55.1 % (40.2-69.3 %), LED-FM was 37 % (19.4-57.6 %) and Xpert was 77.6 % (66.6-86.4 %) whereas in ILs the same value for ZN was 58.3 % (27.7-84.8 %), LED-FM was 62.5 % (24.5-91.5 %) and Xpert was 90 (68.3-98.8 %). The sensitivity for all tests was significantly higher among HIV-negative individuals (all test p <0.05). The overall incremental sensitivity of Xpert over smear microscopy was 32.3 %; p < 0.0001. The incremental sensitivity of Xpert was statistically significant for both smear methods at PL (32.9 %; p = 0.001) but not at the ILs (30 %; p = 0.125) for both smear methods. Our study findings of the early implementation of the LED-FM did not reveal significant increment in sensitivity compared to the method being phased out (ZN). This study showed a significant incremental sensitivity for Xpert from both smear methods at peripheral centers where majority of TB patients are diagnosed. Overall our findings support the recommendation for Xpert as an initial diagnostic test in adults and children presumed to have TB.

  18. Clinical evaluation of high-risk HPV detection on self-samples using the indicating FTA-elute solid-carrier cartridge.

    PubMed

    Geraets, D T; van Baars, R; Alonso, I; Ordi, J; Torné, A; Melchers, W J G; Meijer, C J L M; Quint, W G V

    2013-06-01

    High-risk human papillomavirus (hrHPV) testing in cervical screening is usually performed on physician-taken cervical smears in liquid-based medium. However, solid-state specimen carriers allow easy, non-hazardous storage and transportation and might be suitable for self-collection by non-responders in screening and in low-resource settings. We evaluated the adequacy of self-collected cervicovaginal (c/v) samples using a Viba-brush stored on an Indicating FTA-elute cartridge (FTA-based self-sampling) for hrHPV testing in women referred to a gynecology clinic due to an abnormal smear. 182 women accepted to self-collect a c/v sample. After self-sampling, a physician obtained a conventional liquid-based cervical smear. Finally, women were examined by colposcopy and a biopsy was taken when clinically indicated. Self-samples required only simple DNA elution, and DNA was extracted from physician-obtained samples. Both samples were tested for 14 hrHPVs by GP5+/6+-EIA-LQ Test and SPF(10)-DEIA-LiPA(25). Both assays detected significantly more hrHPV in physician-collected specimens than in self-collected samples (75.3% and 67.6% by SPF(10); 63.3% and 53.3% by GP5+/6+, respectively). The combination of physician-collected specimen and GP5+/6+ testing demonstrated the optimal balance in sensitivity (98.0%) and specificity (48.1%) for CIN2+ detection in this referral population. A test system of FTA-based self-collection and SPF(10) hrHPV detection approached this sensitivity (95.9%) and specificity (42.9%). These results show that the clinical performance of hrHPV detection is determined by both the sample collection system and the test method. FTA-based self-collection with SPF(10) testing might be valuable when a liquid-based medium cannot be used, but requires further investigation in screening populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Clinical and epidemiological characteristics of cutaneous leishmaniasis in Sri Lanka.

    PubMed

    Iddawela, Devika; Vithana, Sanura Malinda Pallegoda; Atapattu, Dhilma; Wijekoon, Lanka

    2018-03-06

    Leishmaniasis, a vector borne tropical/subtropical disease caused by the protozoan Leishmania is transmitted to humans by sandfly vectors Phlebotomus and Lutzomyia. The principal form found in Sri Lanka is cutaneous leishmaniasis (CL) and is caused by Leishmania donovani. A rising trend in disease prevalence has been observed recently in Sri Lanka and the island is in fact the newest endemic focus in South Asia. Determining the prevalence of smear positivity among clinically suspected CL patients, identifying risk factors and specific clinical presentations of CL in order to implement preventive and early treatment strategies were the objectives of this study. A sample of 509 clinically suspected cases of CL referred to the Department of Parasitology from all across Sri Lanka between 2005 and 2015 was selected consecutively. Diagnosis was confirmed by microscopic visualization of the Leishmania amastigote from the slit skin smear. A structured questionnaire was used to identify exposure related risk factors and a clinical examination was performed to identify lesion characteristics. Out of 509 clinical cases, 41.5% (n = 211) were smear positive. The study population ranged from ages 1 to 80 years (mean age = 34.76) and the most affected age group was 40-49. Of the smear positives, 58.85% were males. Majority (47.86%) were from the North Western region (Kurunegala) of the country and were exposed to scrub jungles. Sand fly exposure (p = 0.04) and positive contact history (p = 0.005) were significant risk factors for smear positivity. Erythema (p = 0.02), lack of pruritus (p = 0.02) and scaly appearance (p = 0.003) were significant lesion characteristics in smear positivity. Lesions were commonly found in the exposed areas and the commonest morphological type was papulo-nodular. An increasing trend in the spread of cutaneous leishmaniasis from endemic to non-endemic areas has become evident. Positive contact history and sandfly exposure were significant risk factors for smear positivity which may indicate the possibility of human reservoir hosts in infection transmission. Lack of pruritus, scaly appearance and erythema were highly significant lesion characteristics associated with Leishmania positive smears which can be used for the clinical diagnosis of CL.

  20. Significance of atypical squamous cells of undetermined significance on ThinPrep papanicolaou smears.

    PubMed

    Eltabbakh, G H; Lipman, J N; Mount, S L; Morgan, A

    2000-10-01

    The aim of this study was to assess the prevalence and risk factors predictive of dysplasia among women seen in a gynecologic oncology service with the cytologic diagnosis of atypical squamous cells of undetermined significance (ASCUS) on Papanicolaou smears obtained by the ThinPrep method. Patients with ASCUS ThinPrep Papanicolaou smears seen at the Division of Gynecologic Oncology, University of Vermont, between 1997 and 1999 were identified. The cytologic smears were reviewed and subtyped into reactive or suggestive of squamous intraepithelial lesion (SIL). The charts of these patients were reviewed and the following information was abstracted: age, gravidity, parity, menopausal status, use of hormonal replacement therapy, smoking, history of pelvic cancer, history of radiation therapy, history of abnormal Papanicolaou smear and its treatment, history of human papillomavirus (HPV) infection, and follow-up information including results of repeat Papanicolaou smears, colposcopy, and biopsies. The prevalence of dysplasia was calculated. The demographic features of women with ASCUS, reactive, were compared with those with ASCUS, SIL, using a two-sample t test, chi(2), and Fisher's exact test. Risk factors predictive of dysplasia were calculated using the odds ratio and the 95% confidence interval. P < 0.05 was considered significant. One hundred twenty-six patients with ASCUS on ThinPrep Papanicolaou smear were identified; 63 patients had ASCUS, reactive, and 63 patients had ASCUS, SIL. The demographic features of both groups were similar. The overall prevalence of dysplasia was 15.9% and was significantly higher among women with ASCUS, SIL, than among women with ASCUS, reactive (25.4% versus 6.4%, P = 0.003). The type of ASCUS cytology (reactive versus SIL), smoking, and history of HPV were significant risk factors for dysplasia (P = 0.003, 0.037, and 0. 042, respectively). The prevalence of dysplasia among women seen in a gynecologic oncology service with ASCUS cytology on ThinPrep Papanicolaou smears is 15.9%. Women with ASCUS favor SIL, those who smoke, and those with a history of HPV are at higher risk for dysplasia and should be offered colposcopy. Copyright 2000 Academic Press.

  1. Combined in vivo and ex vivo analysis of mesh mechanics in a porcine hernia model.

    PubMed

    Kahan, Lindsey G; Lake, Spencer P; McAllister, Jared M; Tan, Wen Hui; Yu, Jennifer; Thompson, Dominic; Brunt, L Michael; Blatnik, Jeffrey A

    2018-02-01

    Hernia meshes exhibit variability in mechanical properties, and their mechanical match to tissue has not been comprehensively studied. We used an innovative imaging model of in vivo strain tracking and ex vivo mechanical analysis to assess effects of mesh properties on repaired abdominal walls in a porcine model. We hypothesized that meshes with dissimilar mechanical properties compared to native tissue would alter abdominal wall mechanics more than better-matched meshes. Seven mini-pigs underwent ventral hernia creation and subsequent open repair with one of two heavyweight polypropylene meshes. Following mesh implantation with attached radio-opaque beads, fluoroscopic images were taken at insufflation pressures from 5 to 30 mmHg on postoperative days 0, 7, and 28. At 28 days, animals were euthanized and ex vivo mechanical testing performed on full-thickness samples across repaired abdominal walls. Testing was conducted on 13 mini-pig controls, and on meshes separately. Stiffness and anisotropy (the ratio of stiffness in the transverse versus craniocaudal directions) were assessed. 3D reconstructions of repaired abdominal walls showed stretch patterns. As pressure increased, both meshes expanded, with no differences between groups. Over time, meshes contracted 17.65% (Mesh A) and 0.12% (Mesh B; p = 0.06). Mesh mechanics showed that Mesh A deviated from anisotropic native tissue more than Mesh B. Compared to native tissue, Mesh A was stiffer both transversely and craniocaudally. Explanted repaired abdominal walls of both treatment groups were stiffer than native tissue. Repaired tissue became less anisotropic over time, as mesh properties prevailed over native abdominal wall properties. This technique assessed 3D stretch at the mesh level in vivo in a porcine model. While the abdominal wall expanded, mesh-ingrown areas contracted, potentially indicating stresses at mesh edges. Ex vivo mechanics demonstrate that repaired tissue adopts mesh properties, suggesting that a better-matched mesh could reduce changes to abdominal wall mechanics.

  2. Updates to Simulation of a Single-Element Lean-Direct Injection Combustor Using a Polyhedral Mesh Derived From Hanging-Node Elements

    NASA Technical Reports Server (NTRS)

    Wey, Changju Thomas; Liu, Nan-Suey

    2014-01-01

    This paper summarizes the procedures of inserting a thin-layer mesh to existing inviscid polyhedral mesh either with or without hanging-node elements as well as presents sample results from its applications to the numerical solution of a single-element LDI combustor using a releasable edition of the National Combustion Code (NCC).

  3. Updates to Simulation of a Single-Element Lean-Direct Injection Combustor Using a Polyhedral Mesh Derived from Hanging-Node Elements

    NASA Technical Reports Server (NTRS)

    Wey, Thomas; Liu, Nan-Suey

    2014-01-01

    This paper summarizes the procedures of inserting a thin-layer mesh to existing inviscid polyhedral mesh either with or without hanging-node elements as well as presents sample results from its applications to the numerical solution of a single-element LDI combustor using a releasable edition of the National Combustion Code (NCC).

  4. Laboratory productivity and the rate of manual peripheral blood smear review: a College of American Pathologists Q-Probes study of 95,141 complete blood count determinations performed in 263 institutions.

    PubMed

    Novis, David A; Walsh, Molly; Wilkinson, David; St Louis, Mary; Ben-Ezra, Jonathon

    2006-05-01

    Automated laboratory hematology analyzers are capable of performing differential counts on peripheral blood smears with greater precision and more accurate detection of distributional and morphologic abnormalities than those performed by manual examinations of blood smears. Manual determinations of blood morphology and leukocyte differential counts are time-consuming, expensive, and may not always be necessary. The frequency with which hematology laboratory workers perform manual screens despite the availability of labor-saving features of automated analyzers is unknown. To determine the normative rates with which manual peripheral blood smears were performed in clinical laboratories, to examine laboratory practices associated with higher or lower manual review rates, and to measure the effects of manual smear review on the efficiency of generating complete blood count (CBC) determinations. From each of 3 traditional shifts per day, participants were asked to select serially, 10 automated CBC specimens, and to indicate whether manual scans and/or reviews with complete differential counts were performed on blood smears prepared from those specimens. Sampling continued until a total of 60 peripheral smears were reviewed manually. For each specimen on which a manual review was performed, participants indicated the patient's age, hemoglobin value, white blood cell count, platelet count, and the primary reason why the manual review was performed. Participants also submitted data concerning their institutions' demographic profiles and their laboratories' staffing, work volume, and practices regarding CBC determinations. The rates of manual reviews and estimations of efficiency in performing CBC determinations were obtained from the data. A total of 263 hospitals and independent laboratories, predominantly located in the United States, participating in the College of American Pathologists Q-Probes Program. There were 95,141 CBC determinations examined in this study; participants reviewed 15,423 (16.2%) peripheral blood smears manually. In the median institution (50th percentile), manual reviews of peripheral smears were performed on 26.7% of specimens. Manual differential count review rates were inversely associated with the magnitude of platelet counts that were required by laboratory policy to trigger smear reviews and with the efficiency of generating CBC reports. Lower manual differential count review rates were associated with laboratory policies that allowed manual reviews solely on the basis of abnormal automated red cell parameters and that precluded performing repeat manual reviews within designated time intervals. The manual scan rate elevated with increased number of hospital beds. In more than one third (35.7%) of the peripheral smears reviewed manually, participants claimed to have learned additional information beyond what was available on automated hematology analyzer printouts alone. By adopting certain laboratory practices, it may be possible to reduce the rates of manual reviews of peripheral blood smears and increase the efficiency of generating CBC results.

  5. NEAMS Update. Quarterly Report for January - March 2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stan, Marius

    2014-08-01

    This quarterly report covers the following points: A fully three-dimensional smeared cracking model has been implemented and tested in BISON; DAKOTA-BISON was used to study the parameters that govern heat transfer across the fuel-cladding; Calculations of grain boundary mobility in UO 2 have been extended to high temperatures; Mesh adaptivity is being employed in MARMOT simulations to increase computational efficiency; Molecular dynamics simulations have shown correlation between atomic displacements and the anisotropic thermal conductivity in UO 2; The SHARP team continues to address the application of the toolkit to assembly deformations driven by reactivity feedback; The Nek5000 team has extendedmore » the low-Machnumber capability to mixtures with multiple species; The generalized cross section library has been tested for various fuel assemblies and reactor types; and The subgroup cross-section interface was successfully implemented in PROTEUS-SN (page 6).« less

  6. More experiences with the Tzanck smear test: cytologic findings in cutaneous granulomatous disorders.

    PubMed

    Durdu, Murat; Baba, Mete; Seçkin, Deniz

    2009-09-01

    Granulomatous dermatitis is a distinctive histopathologic cutaneous reaction pattern against various infectious and noninfectious agents. Cytologically, granulomatous dermatitis shows granulomas and multinucleated giant cells. Various etiologic agents of granulomatous diseases can also be identified. We aimed to investigate Tzanck smear findings in granulomatous skin diseases. Patients who had granulomas and/or multinucleated giant cells of Langhans, foreign body- and/or Touton type in Tzanck smear tests were included in the study. In these patients, Tzanck preparations were then further evaluated for additional cytologic findings. Samples stained with May-Grünwald-Giemsa stain were evaluated by the same dermatologist throughout the study. In some patients, methylene blue, Gram and/or Erlich-Ziehl-Nielsen stains were also performed. In all of the study cases, the final diagnosis was established after the evaluation of clinical and laboratory findings (including, when appropriate, potassium hydroxide examination; bacterial, leishmanial, and fungal cultures; histopathology; tuberculosis and leishmania polymerase chain reaction). We also calculated the sensitivity and specificity of the Leishman-Donovan body for cutaneous leishmaniasis. Over a 2-year period, 94 of 950 patients (9.9%) in whom Tzanck smear tests were performed had cytologic findings consistent with a granulomatous reaction. In 74 (78.7%) and 20 (21.3%) patients, the granulomatous reaction was due to infectious and noninfectious causes, respectively. Infectious causes included cutaneous leishmaniasis in 65 patients (87.8%), candidal granuloma in two patients, botyromycosis in two patients, and aspergillosis, blastomycosis, mucormycosis, leprosy, and cutaneous tuberculosis in one patient each. In 58 of 74 patients (78.4%) with infectious granulomatous dermatitis, the causes of the granulomas were identified. Noninfectious granulomatous reactions were due to granuloma annulare in 7 patients, sarcoidosis in 5 patients, a foreign body in 4 patients, necrobiosis lipoidica in 2 patients, and juvenile xanthogranuloma in 2 patients. In 17 of 20 patients (85%) with noninfectious granulomatous reactions, the cytologic findings were characteristic of the final diagnoses. The sensitivity and specificity of Leishman-Donovan bodies for cutaneous leishmaniasis were 76.9% and 100%, respectively. All of the samples were evaluated by the same dermatologist throughout the study; therefore no comment could be made regarding the reliability of the Tzanck smear test. In addition, the sensitivity and specificity of Tzanck smear test findings for diseases other than cutaneous leishmaniasis could not be calculated because of an insufficient number of patients. The Tzanck smear test may be a useful diagnostic tool for certain granulomatous skin diseases.

  7. The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi.

    PubMed

    Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L

    2016-01-01

    Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis.

  8. The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi

    PubMed Central

    Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L.

    2016-01-01

    Background Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. Objective To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Methods Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Results Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). Conclusion The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis. PMID:27171380

  9. Sputum smear examination and time to diagnosis in patients with smear-negative pulmonary tuberculosis in the Pacific

    PubMed Central

    Bissell, K.; Tabutoa, K.; Kienene, T.; Linh, N. N.; Briand, K.; Harries, A. D.

    2012-01-01

    Setting: National tuberculosis programmes (NTPs) in Kiribati and the Marshall Islands, 2006–2010. Objective: To determine the proportion of all tuberculosis (TB) cases that were pulmonary smear-negative, and for these patients to determine how many sputum smears were examined and the time from sputum smear examination to registration. Design: A retrospective cross-sectional study involving a record review of national TB and laboratory registers. Results: Of 2420 TB cases identified, 709 (29%) were registered as smear-negative pulmonary TB. Of the 695 (98%) with information on smear examination, 222 (32%) had no smear recorded, 61 (9%) had one smear, 86 (12%) two smears and 326 (47%) three smears. Among the 473 patients who had at least one smear, 238 (50%) were registered before sputum examination, 131 (28%) within 1 week, 72 (15%) between 1 and 4 weeks, and 34 (7%) >4 weeks after sputum examination. Conclusion: NTPs in Kiribati and the Marshall Islands are diagnosing 29% of all TB patients as smear-negative pulmonary TB. Many patients do not have smears done or are registered before undergoing smear examination. Corrective measures are needed. PMID:26392971

  10. Comparative analysis of histopathologic effects of synthetic meshes based on material, weight, and pore size in mice.

    PubMed

    Orenstein, Sean B; Saberski, Ean R; Kreutzer, Donald L; Novitsky, Yuri W

    2012-08-01

    While synthetic prosthetics have essentially become mandatory for hernia repair, mesh-induced chronic inflammation and scarring can lead to chronic pain and limited mobility. Mesh propensity to induce such adverse effects is likely related to the prosthetic's material, weight, and/or pore size. We aimed to compare histopathologic responses to various synthetic meshes after short- and long-term implantations in mice. Samples of macroporous polyester (Parietex [PX]), heavyweight microporous polypropylene (Trelex[TX]), midweight microporous polypropylene (ProLite[PL]), lightweight macroporous polypropylene (Ultrapro[UP]), and expanded polytetrafluoroethylene (DualMesh[DM]) were implanted subcutaneously in mice. Four and 12 wk post-implantation, meshes were assessed for inflammation, foreign body reaction (FBR), and fibrosis. All meshes induced varying levels of inflammatory responses. PX induced the greatest inflammatory response and marked FBR. DM induced moderate FBR and a strong fibrotic response with mesh encapsulation at 12 wk. UP and PL had the lowest FBR, however, UP induced a significant chronic inflammatory response. Although inflammation decreased slightly for TX, marked FBR was present throughout the study. Of the three polypropylene meshes, fibrosis was greatest for TX and slightly reduced for PL and UP. For UP and PL, there was limited fibrosis within each mesh pore. Polyester mesh induced the greatest FBR and lasting chronic inflammatory response. Likewise, marked fibrosis and encapsulation was seen surrounding ePTFE. Heavier polypropylene meshes displayed greater early and persistent fibrosis; the reduced-weight polypropylene meshes were associated with the least amount of fibrosis. Mesh pore size was inversely proportional to bridging fibrosis. Moreover, reduced-weight polypropylene meshes demonstrated the smallest FBR throughout the study. Overall, we demonstrated that macroporous, reduced-weight polypropylene mesh exhibited the highest degree of biocompatibility at sites of mesh implantation. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Primary Multidrug Resistant Tuberculosis and Utility of Line Probe Assay for Its Detection in Smear-Positive Sputum Samples in a Tertiary Care Hospital in South India.

    PubMed

    Yacoob, Fahmiya Leena; Philomina Jose, Beena; Karunakaran Lelitha, Sarada Devi; Sreenivasan, Sreelatha

    2016-01-01

    In a high tuberculosis burdened country like India, rapid, cost-effective, and reliable diagnostic tools for tuberculosis are an urgent need of the hour to prevent inappropriate treatment strategies and further spread of resistance. This study aimed to estimate the proportion of new smear-positive tuberculosis cases with primary resistance to rifampicin and/or isoniazid as well as identify the common mutations associated with it. Sputum of 200 newly diagnosed smear-positive cases of 1+ score and above was directly subjected to Line Probe Assay using the GenoType MTBDRplus assay kit. All samples were inoculated onto solid media and 61 samples were inoculated in automated liquid culture also. The Line Probe Assay gave hundred percent interpretable results with 2.5% of the study population showing resistant pattern. Only 1% of the cases were primary multidrug resistant tuberculosis and 1.5% showed isoniazid monoresistance. S531L and C15T were the most common genetic mutations seen for rifampicin and isoniazid resistance, respectively. 40% had absent rpoB wild type 8 band indicating probable silent mutation after clinical correlation. The average turnaround time for Line Probe Assay was far less (3.8 days) as compared to solid and liquid cultures (35.6 days and 13.5 days, resp.).

  12. Understanding Transgender Men's Experiences with and Preferences for Cervical Cancer Screening: A Rapid Assessment Survey.

    PubMed

    Seay, Julia; Ranck, Atticus; Weiss, Roy; Salgado, Christopher; Fein, Lydia; Kobetz, Erin

    2017-08-01

    Transgender men are less likely than cisgender women to receive cervical cancer screening. The purpose of the current study was to understand experiences with and preferences for cervical cancer screening among transgender men. Ninety-one transgender men ages 21-63 completed the survey. The survey evaluated experiences with and preferences for screening, including opinions regarding human papillomavirus (HPV) self-sampling as a primary cervical cancer screening. Half (50.5%) of participants did not have Pap smear screening within the past 3 years. The majority (57.1%) of participants preferred HPV self-sampling over provider-collected Pap smear screening. Participants who reported discrimination were more likely to prefer HPV self-sampling (odds ratio = 3.29, 95% confidence interval 1.38-7.84, P = 0.007). Primary HPV testing via HPV self-sampling may improve cervical cancer screening uptake among transgender men. Future work should pilot this innovative cervical cancer screening method within this population.

  13. Recovery of macroinvertebrates by screening in the field: a comparison between coarse (1.18 mm) and fine (0.60 mm) mesh sieves

    USGS Publications Warehouse

    Dukerschein, J.T.; Gent, R.; Sauer, J.

    1996-01-01

    We evaluated the potential loss of target benthic macroinvertebrates from coarse-mesh field wash down of samples through a 1.18-mm mesh sieve nested on a 0.60-mm mesh sieve. Visible target organisms (midges, mayflies, and fingernail clams) in the 1.18-mm mesh sieve were removed from the sample and enumerated in the field. The entire contents of both sieves were preserved for subsequent laboratory enumeration under 4X magnification. Percent recoveries from each treatment were based on total intact organisms found in all sieves. Percent recovery for fingernail clams found in the field (31%) was lower than for mayflies (79%) and midges (88%). Laboratory enumeration of organisms retained by the 1.18-mm sieve yielded additional fingernail clams (to total 74% recovered in the field and lab), mayflies (to total 89%), and midges (to total 91%). If the 1.18-mm sieve is used alone in the field, it is adequate to monitor mayflies, midges >1 cm, and adult fingernail clams greater than or equal to 5.0 mm shell length.

  14. Reliability of unaided naked-eye examination as a screening test for cervical lesions in a developing country setup.

    PubMed

    Darwish, Atef M; Abdulla, Sayed A; Zahran, Kamal M; Abdel-Fattah, Nermat A

    2013-04-01

    This study aimed to test the reliability of unaided naked-eye examination (UNEE) of the cervix as a sole cervical cancer screening test in a developing country setup compared with the standard cervical cytology. A total of 3,500 nonpregnant women aged between 25 and 55 years were included. An unlubricated bivalve speculum was inserted into the vagina under good light to visualize the cervix. A thorough UNEE of the cervix was done to detect any apparent lesions. Cervical smears were obtained using the long tip of an Ayre spatula. An additional endocervical sample was obtained by cytobrush. Women with abnormal Pap smears or visible cervical lesions by UNEE were scheduled for colposcopic examination. A biopsy specimen was obtained in every abnormal colposcopic examination. Of 3,500 cases, there were 9 (2.57%) preinvasive cervical lesions (cervical intraepithelial neoplasia 1-3) diagnosed with various diagnostic tools used in the study and confirmed by histopathologic examination. Of 3,500 cases, invasive cervical lesions were diagnosed in 6 (1.71%). The sensitivity of UNEE is much better than that of Pap smear (80% vs 60%) but less than that of colposcopy (86.7%). However, the specificity of UNEE (100%) is lower than that of Pap smear (91.16%) and better than that colposcopy (83.12%). The UNEE has a poor positive predictive value (3.75%) when compared with Pap smear (100%) and colposcopy (20%). The negative predictive values of the 3 tests were nearly comparable. Whenever access to Pap smear is limited, UNEE performed by general gynecologists and well-trained nurses is an acceptable alternative for detecting cervical premalignant or malignant lesions especially in low-resource settings.

  15. Risk factors for unsuccessful tuberculosis treatment outcome (failure, default and death) in public health institutions, Eastern Ethiopia.

    PubMed

    Amante, Tariku Dingeta; Ahemed, Tekabe Abdosh

    2015-01-01

    Unsuccessful TB treatment outcome is a serious public health concern. It is compelling to identify, and deal with factors determining unsuccessful treatment outcome. Therefore, study was aimed to determine pattern of unsuccessful TB treatment outcome and associated factors in eastern Ethiopia. A case control study was used. Cases were records of TB patients registered as defaulter, dead and/or treatment failure where as controls were those cured or treatment complete. Multivariate logistic regression models were used to derive adjusted odds ratios (OR) at 95% CI to examine the relationship between the unsuccessful TB treatment outcome and patients' characteristics. A total of 990 sample size (330 cases and 660 controls) were included. Among cases (n = 330), majority 212(64.2%) were because of death, 100(30.3%) defaulters and 18(5.5%) were treatment failure. Lack of contact person(OR = 1.37; 95% CI 1.14-2.9, P, .024), sputum smear negative treatment category at initiation of treatment (OR = 1.8; 95% CI 1.3-5.5,P, .028), smear positive sputum test result at 2(nd) month after initiation treatment (OR = 14; 95% CI 5.5-36, P,0.001) and HIV positive status (OR = 2.5; 95% CI 1.34-5.7, P, 0.01) were independently associated with increased risk of unsuccessful TB treatment outcome. Death was the major cause of unsuccessful TB treatment outcome. TB patients do not have contact person, sputum smear negative treatment category at initiation of treatment, smear positive on 2(nd) month after treatment initiation and HIV positive were factors significantly associated unsuccessful treatment outcome. TB patients with sputum smear negative treatment category, HIV positive and smear positive on 2(nd) nd month of treatment initiation need strict follow up throughout DOTs period.

  16. The self-adjusting file (SAF). Part 3: removal of debris and smear layer-A scanning electron microscope study.

    PubMed

    Metzger, Zvi; Teperovich, Ehud; Cohen, Raphaela; Zary, Raviv; Paqué, Frank; Hülsmann, Michael

    2010-04-01

    The aim of this study was to evaluate the cleaning ability of the Self-Adjusting File (SAF) system in terms of removal of debris and smear layer. Root canal preparations were performed in 20 root canals using an SAF operated with a continuous irrigation device. The glide path was initially established using a size 20 K-file followed by the SAF file that was operated in the root canal via a vibrating motion for a total of 4 minutes. Sodium hypochlorite (3%) and EDTA (17%) were used as continuous irrigants and were alternated every minute during this initial 4-minute period. This was followed by a 30-second rinse using EDTA applied through a nonactivated SAF and a final flush with sodium hypochlorite. The roots were split longitudinally and subjected to scanning electron microscopy (SEM). The presence of debris and a smear layer in the coronal, middle, and apical thirds of the canal were evaluated through the analysis of the SEM images using five-score evaluation systems based on reference photographs. The SAF operation with continuous irrigation, using alternating irrigants, resulted in root canal walls that were free of debris in all thirds of the canal in all (100%) of the samples. In addition, smear layer-free surfaces were observed in 100% and 80% of the coronal and middle thirds of the canal, respectively. In the apical third of the canal, smear layer-free surfaces were found in 65% of the root canals. The operation of the SAF system with continuous irrigation coupled with alternating sodium hypochlorite and EDTA treatment resulted in a clean and mostly smear layer-free dentinal surface in all parts of the root canal. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Factors Associated with Persistent Sputum Positivity at the End of the Second Month of Tuberculosis Treatment in Lithuania.

    PubMed

    Diktanas, Saulius; Vasiliauskiene, Edita; Polubenko, Katazyna; Danila, Edvardas; Celedinaite, Indre; Boreikaite, Evelina; Misiunas, Kipras

    2018-06-19

    Non-conversion of sputum smear and culture prolongs the infectivity of the patient and has been associated with unfavorable outcomes. We aimed to evaluate factors associated with persistent sputum positivity at the end of two months of treatment of new case pulmonary tuberculosis (TB). Data of 87 human immunodeficiency virus-negative patients with culture-positive drug-susceptible pulmonary TB admitted to local university hospital between September 2015 and September 2016 were reviewed. Factors associated with sputum smear and/or culture positivity at the end of the second month of treatment were analyzed. Twenty-two patients (25.3%) remained smear and/or culture-positive. Male sex, lower body mass index (BMI), unemployment, alcohol abuse, higher number of lobes involved and cavities on chest X-rays, shorter time to detection (TTD) on liquid cultures, higher respiratory sample smear grading and colony count in solid cultures, higher C-reactive protein, erythrocyte sedimentation rate, leukocytosis, thrombocytosis, and anemia were all significantly associated with persistent sputum positivity. However, in the logistic regression analysis only male sex, lower BMI, alcohol abuse, higher radiological involvement, cavitation, higher smear grading, higher colony count in solid cultures and shorter TTD were determined as independent factors associated with persistent sputum positivity at the end of 2 months of treatment. In conclusion, higher sputum smear and culture grading at diagnosis, shorter TTD, higher number of lobes involved, cavitation, male sex, alcohol abuse, and lower BMI were independently associated with persistent sputum positivity. These factors should be sought when distinguishing which patients will remain infectious longer and possibly have worse outcomes. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  18. A preliminary parasitological survey of hepatozoon spp. Infection in dogs in mashhad, iran.

    PubMed

    Amoli, Aa Rahmani; Khoshnegah, J; Razmi, Ghr

    2012-01-01

    We attempted to determine the prevalence of Hepatozoon spp. infection in Mashhad, northeast of Iran, via blood smear parasitology. The prevalence was investigated by examination of blood smear parasitology, using blood samples collected from 254 dogs (51 strays and 203 privately owned-dogs). Two stray dogs (2/51; 3.92%) and two privately-owned dogs (2/203; 0.98%) were infected with Hepatozoon spp. Therefore, as per blood smear parasitology, the prevalence of Hepatozoon spp. infection was 1.57% (4/254). Sixteen out of 254 dogs (6.29%) were infested with ticks; all of which were Rhipicephalus sanguineus. One of the dogs infected with Hepatozoon spp. exhibited ticks at the time of examination. Concurrent infection with Ehrlichia canis and Leishmania infantum was not detected in the four Hepatozoon spp. infected dogs. This is the first epidemiological study on the prevalence of Hepatozoon spp. infection in dogs in Iran.

  19. A Preliminary Parasitological Survey of Hepatozoon Spp. Infection in Dogs in Mashhad, Iran

    PubMed Central

    Amoli, AA Rahmani; Khoshnegah, J; Razmi, GhR

    2012-01-01

    Background We attempted to determine the prevalence of Hepatozoon spp. infection in Mashhad, northeast of Iran, via blood smear parasitology. Methods The prevalence was investigated by examination of blood smear parasitology, using blood samples collected from 254 dogs (51 strays and 203 privately owned-dogs). Results Two stray dogs (2/51; 3.92%) and two privately-owned dogs (2/203; 0.98%) were infected with Hepatozoon spp. Therefore, as per blood smear parasitology, the prevalence of Hepatozoon spp. infection was 1.57% (4/254). Sixteen out of 254 dogs (6.29%) were infested with ticks; all of which were Rhipicephalus sanguineus. One of the dogs infected with Hepatozoon spp. exhibited ticks at the time of examination. Concurrent infection with Ehrlichia canis and Leishmania infantum was not detected in the four Hepatozoon spp. infected dogs. Conclusion This is the first epidemiological study on the prevalence of Hepatozoon spp. infection in dogs in Iran. PMID:23323098

  20. Abnormal Papanicolaou smears, genital tract infections, and contraception.

    PubMed

    Hawkins, J W; Matteson, P S; Mersha, G

    1999-01-01

    Cervical cancer ranks second among all cancers in women world-wide, and the rate of invasive cervical cancer among women under 50 is rising in the United States. Risk factors for abnormal Papanicolaou (Pap) smears and invasive cervical cancer include genital tract infections. This study was designed to compare the rates of genital tract infections and the contraceptive choices of a random sample of 800 women, using an ex post facto design. The Pap positive women had a significantly higher rate of genital tract infections than did the Pap negative women but did not differ significantly in use of contraceptive methods. Findings support those of other researchers suggesting genital tract infections as risk factors for abnormal Pap smears and are consistent with the literature in suggesting a role for oral contraceptive pills (OCPs) in acquisition of the human papillomavirus (HPV). Caregivers can help empower women to reduce their risks through informed choices about protection and sexual behaviors.

  1. Utility of a point-of-care malaria rapid diagnostic test for excluding malaria as the cause of fever among HIV-positive adults in rural Rakai, Uganda.

    PubMed

    Mills, Lisa A; Kagaayi, Joseph; Nakigozi, Gertrude; Galiwango, Ronald M; Ouma, Joseph; Shott, Joseph P; Ssempijja, Victor; Gray, Ronald H; Wawer, Maria J; Serwadda, David; Quinn, Thomas C; Reynolds, Steven J

    2010-01-01

    We compared results of a malaria rapid diagnostic test (Binax Now Malaria, Binax-M, Inverness Medical Innovations, Inc., Waltham, MA) performed at rural mobile clinics in Uganda by clinicians evaluating febrile adult HIV patients to thick smear evaluated at a central laboratory by trained microscopists. Two hundred forty-six samples were analyzed, including 14 (5.7%) which were thick-smear positive for falciparum malaria. Sensitivity of Binax-M compared with thick smear was 85.7% (95% CI: 57.2-98.2), specificity 97.8% (95% CI: 94.9-99.3), positive and negative predictive values were 70.6% (95% CI: 44.0-89.7) and 99.1% (95% CI: 96.8-99.9), respectively. The rapid diagnostic test accurately ruled malaria "in or out" at the point-of-care, facilitating appropriate clinical management and averting unnecessary anti-malarial therapy.

  2. Role of intraoperative imprint cytology in diagnosis of suspected ovarian neoplasms.

    PubMed

    Dey, Soumit; Misra, Vatsala; Singh, P A; Mishra, Sanjay; Sharma, Nishant

    2010-01-01

    The present study was conducted to assess whether cytology can help in rapid diagnosis of ovarian neoplasms and thus facilitate individualised treatment. A prospective investigation was performed on 30 cases of suspected ovarian neoplasms. Imprint smears were made intraperatively from fresh samples from various representative areas, and stained with Leishman Giemsa for air-dried smears, and with hematoxylin and eosin and Papanicolaou for alcohol-fixed smears. A rapid opinion regarding the benign or malignant nature of the lesion and the type of tumour was given. The overall sensitivity was 96.2%, specificity 75%, positive predictive value 96.3%, and diagnostic accuracy of 83.3%. Characteristic cytological patterns were noted in various epithelial and germ cell tumours. Imprint cytology can be used as an adjunct to histopathology for rapid and early diagnosis in the operation theatre, thus helping better management of patients.

  3. Prevalence of high-risk human papilloma virus types and cervical smear abnormalities in female sex workers in Chandigarh, India.

    PubMed

    Singh, M P; Kaur, M; Gupta, N; Kumar, A; Goyal, K; Sharma, A; Majumdar, M; Gupta, M; Ratho, R K

    2016-01-01

    Cervical cancer is the most common cancer among women in developing nations. Nearly 90% of the cases have been linked to the presence of high-risk human papillomavirus (hrHPV) types 16 and 18. The risk of cervical cancer may be high in female sex workers (FSWs) due to multiple sexual partners. This study aimed to determine the prevalence of cytological abnormalities and hrHPV types 16 and 18 in FSWs in Chandigarh, North India using the liquid-based cytology (LBC) approach. The cervical brush samples were collected from 120 FSW and 98 age-matched healthy controls (HCs). These were subjected to pap smear using conventional method, LBC and the detection of hrHPV types 16 and 18 was carried out using polymerase chain reaction. The LBC samples showed better cytological details and also reduced the number of unsatisfactory smears from 11% in Pap to 1.5% in the LBC. A significantly higher number of inflammatory smears were reported in FSWs (51.7% vs. 34.7%, P = 0.01). The hrHPV types 16/18 were detected in 33/120 (27.5%) FSW versus 23/98 (23.5%) HCs. The risk of acquiring hrHPV was higher in FSWs, who had age at first sex ≤25 years, higher income and the habit of smoking. The high prevalence of hrHPV among FSWs and HCs suggests the need for the implementation of effective National Screening Programme for early detection of hrHPV types to decrease the burden of cervical cancer, especially in high-risk population.

  4. Testicular cytological profiles of apparently healthy male dromedary camels during rutting and non-rutting periods.

    PubMed

    Melaku, Simenew Keskes; Regassa, Fekadu; Tessema, Tesfaye Sisay; Kassa, Tesfu; Vencato, Juri; Owiny, David Okello; Stelletta, Calogero

    2015-12-01

    The aim of this study was to evaluate testicular cytological profiles of apparently healthy dromedary bulls during rutting and non-rutting periods. Pairs of testes from 26 (18 non-rutting and 8 rutting seasons) dromedary bulls 6-12 years old that were slaughtered at Akaki, Addis Ababa abattoir were sampled. A 21 gauge needle attached to 20mL syringe was used to collect Testicular Fine Needle Aspiration (TFNA) samples and five aspiration smears were prepared from each testis. A total of 312 slides (260 Testicular fine Needle Aspiration and 52 imprints) were examined. The mod ified May-Grunwald Giemsa (mMGG) technique and a light microscope were used to assess cellularity, morphology and quantification of the testicular. Sertoli and spermatogenic cells were identified and counted. The spermatic index (SI), Sertoli cell index (SEI) and the relationship between SI and SEI indexes (SSEI) were used to assess the ratio between mature spermatozoa and nursing cells. There were differences (P<0.05) between the rutting and non-rutting seasons among the spermatogenic and Sertoli cells. There were no differences between groups for primary spermatocyte numbers, early spermatid numbers and SSEI. There was no differences (P>0.05) between TFNA and imprint smear slides of the testicular cells except for Sertoli cell count and SEI. Filarial worm larvae were present on the TFNA smear slides of four animals. Imprint and TFNA smear slides had comparable cytological profiles in dromedary bulls and significant differences were observed between rutting and non-rutting periods. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Compact OAM microscope for edge enhancement of biomedical and object samples

    NASA Astrophysics Data System (ADS)

    Gozali, Richard; Nguyen, Thien-An; Bendau, Ethan; Alfano, Robert R.

    2017-09-01

    The production of orbital angular momentum (OAM) by using a q-plate, which functions as an electrically tunable spatial frequency filter, provides a simple and efficient method of edge contrast in biological and medical sample imaging for histological evaluation of tissue, smears, and PAP smears. An instrument producing OAM, such as a q-plate, situated at the Fourier plane of a 4f lens system, similar to the use of a high-pass spatial filter, allows the passage of high spatial frequencies and enables the production of an image with highly illuminated edges contrasted against a dark background for both opaque and transparent objects. Compared with ordinary spiral phase plates and spatial light modulators, the q-plate has the added advantage of electric control and tunability.

  6. 77 FR 13376 - Notice of License Termination for the University of Arizona Research Reactor, License No. R-52

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-06

    ..., alpha plus beta measurements, smear sampling, and soil sampling activities. As a result of the...-Agency Radiation Survey and Site Investigation Manual.'' The U of AZ submitted a revised FSS Plan on... and that the [[Page 13377

  7. User's guide to PMESH: A grid-generation program for single-rotation and counterrotation advanced turboprops

    NASA Technical Reports Server (NTRS)

    Warsi, Saif A.

    1989-01-01

    A detailed operating manual is presented for a grid generating program that produces 3-D meshes for advanced turboprops. The code uses both algebraic and elliptic partial differential equation methods to generate single rotation and counterrotation, H or C type meshes for the z - r planes and H type for the z - theta planes. The code allows easy specification of geometrical constraints (such as blade angle, location of bounding surfaces, etc.), mesh control parameters (point distribution near blades and nacelle, number of grid points desired, etc.), and it has good runtime diagnostics. An overview is provided of the mesh generation procedure, sample input dataset with detailed explanation of all input, and example meshes.

  8. Use of alpha spectroscopy for conducting rapid surveys of transuranic activity on air sample filters and smears.

    PubMed

    Hayes, Robert B; Peña, Adan M; Goff, Thomas E

    2005-08-01

    This paper demonstrates the utility of a portable alpha Continuous Air Monitor (CAM) as a bench top scalar counter for multiple sample types. These include using the CAM to count fixed air sample filters and radiological smears. In counting radiological smears, the CAM is used very much like a gas flow proportional counter (GFPC), albeit with a lower efficiency. Due to the typically low background in this configuration, the minimum detectable activity for a 5-min count should be in the range of about 10 dpm which is acceptably below the 20 dpm limit for transuranic isotopes. When counting fixed air sample filters, the CAM algorithm along with other measurable characteristics can be used to identify and quantify the presence of transuranic isotopes in the samples. When the radiological control technician wants to take some credit from naturally occurring radioactive material contributions due to radon progeny producing higher energy peaks (as in the case with a fixed air sample filter), then more elaborate techniques are required. The techniques presented here will generate a decision level of about 43 dpm for such applications. The calibration for this application should alternatively be done using the default values of channels 92-126 for region of interest 1. This can be done within 10 to 15 min resulting in a method to rapidly evaluate air filters for transuranic activity. When compared to the 1-h count technique described by , the technique presented in the present work demonstrates a technique whereby more than two thirds of samples can be rapidly shown (within 10 to 15 min) to be within regulatory compliant limits. In both cases, however, spectral quality checks are required to insure sample self attenuation is not a significant bias in the activity estimates. This will allow the same level of confidence when using these techniques for activity quantification as is presently available for air monitoring activity quantification using CAMs.

  9. Critical analysis of vector-borne infections in dogs: Babesia vogeli, Babesia gibsoni, Ehrlichia canis and Hepatozoon canis in Punjab, India.

    PubMed

    Singla, Lachhman Das; Sumbria, Deepak; Mandhotra, Ajay; Bal, M S; Kaur, Paramjit

    2016-12-01

    There are few published studies on various vector borne diseases of dogs in India and most depict clinical infection in dogs, diagnosed by observation of the haemopathogens in stained blood smears. This study provides the first report regarding molecular confirmation and ancestral relationship analysis of blood smears positive cases of assorted haemopathogens in Punjab province of India. On blood smear examination, haemopathogens were observed in 124 out of 778 (15.95%, 95% CI: 13.53- 18.68) blood smears. Further polymerase chain reactions (PCR) was used on bloods smear positive cases to validate the results. Out of 778 blood samples, Babesia gibsoni was most common parasite infecting dogs (15.04%, 95% CI: 12.7-17.72), followed by Ehrlichia canis (0.39%, 95% CI: 0.0-1.13), infection of Babesia vogeli and Hepatozoon canis was same (0.26%, 95% CI: 0.0-0.9). Among various risk factors studied (age, sex, season), prevalence of infection was non-significantly higher in 1-2 year of age group (19.88%, 95% CI: 14.45-26.71), regarding sex same prevalence was recorded (15.94%), and chances of infection was highest in pre-monsoon i.e. summer (18.26%, 95% CI: 14.49-22.76). Phylogenetic analysis revealed ancestral background of Ludhiana isolates of B. vogeli, B. gibsoni, H. canis, and E. canis with the isolates of Philippines, Mongolia and Tunisia.

  10. New technique for the direct analysis of food powders confined in a small hole using transversely excited atmospheric CO(2) laser-induced gas plasma.

    PubMed

    Khumaeni, Ali; Ramli, Muliadi; Deguchi, Yoji; Lee, Yong Inn; Idris, Nasrullah; Kurniawan, Koo Hendrik; Lie, Tjung Jie; Kagawa, Kiichiro

    2008-12-01

    Taking advantage of the differences between the interactions of transversely excited atmospheric (TEA) CO(2) lasers with metal and with organic powder, a new technique for the direct analysis of food powder samples has been developed. In this technique, the powder samples were placed into a small hole with a diameter of 2 mm and a depth of 3 mm and covered by a metal mesh. The TEA CO(2) laser (1500 mJ, 200 ns) was focused on the powder sample surfaces, passing through the metal mesh, at atmospheric pressure in nitrogen gas. It is hypothesized that the small hole functions to confine the powder particles and suppresses the blowing-off of sample, while the metal mesh works as the source of electrons to initiate the strong gas breakdown plasma. The confined powder particles are then ablated by laser irradiation and the ablated particles move into the strong gas breakdown plasma region to be atomized and excited; this method cannot be applied for the case of Nd:YAG lasers because in such case the metal mesh itself was ablated by the laser irradiation. A quantitative analysis of a milk powder sample containing different concentrations of Ca was successfully demonstrated, resulting in a good linear calibration curve with high precision.

  11. Factors Infuencing Women in Pap Smear Uptake

    NASA Astrophysics Data System (ADS)

    Wijayanti, K. E.; Alam, I. G.

    2017-03-01

    Objective: Pap smear has proven can decrease death caused by cervical cancer. However, in Indonesia, only few woman who already did pap smear. The aim of this study was to investigate women’s knowledge about pap smear cervical cancer, and to investigate factors influence women to do pap smear test. Methods: Quantitative data colected through questionairre towards 31 women who did pap smear and 55 women who did not do pap smear. Questionairre was made using Health Belief model as a guideline to examine percieved susceptibility, perceived serioussnes, perceived benefits and perceived barriers. Chi square and multiple logistic regresion were used to investigate difference in knowledge and what the most factor that influence women to take pap smear test. Results: There’s significance knowledge difference betweeen women who did and did not do pap smear. But furthermore, by using Multiple Logistic Regression test, appearantly knowledge was not a strong predictor factor for women to take pap smear test (koefisiensi β = -0,164) Conclusion: Perceived barriers were factors that affected pap smear uptake in women in Indonesia. Few respondents get the wrong informations about pap smear, cevical cancer and its symptoms

  12. Simulation of a Single-Element Lean-Direct Injection Combustor Using Arbitrary Polyhedral Mesh

    NASA Technical Reports Server (NTRS)

    Wey, Thomas; Liu, Nan-Suey

    2012-01-01

    This paper summarizes procedures of generating the arbitrary polyhedral mesh as well as presents sample results from its application to the numerical solution of a single-element LDI combustor using a preliminary version of the new OpenNCC.

  13. THE ROLE OF TARGET ORGAN DIAGNOSTIC APPROACH IN SEASONAL ALLERGIC RHINITIS: NASAL SMEAR EOSINOPHILS.

    PubMed

    Nurkic, Jasmina; Ahmad, Mona Al; Arifhodzic, Nermina; Jusufovic, Edin

    2016-04-01

    Allergic rhinitis (AR) related to local weeds pollen sensitization (Chenopodiaceous family) is the most common cause of respiratory allergy in Kuwait. Local nasal accumulation of different cells typical of allergic inflammation is responsible for clinical symptoms of AR. Although nasal smear for Eosinophils (NSE) is one of the earliest included valuable test in diagnosis of AR, with time is underestimated. Explore possible correlation of natural pollen allergen stimulation with appearance and quantity of Eosinophils in nasal smear. A group of randomly selected patients with clinical history suggestive for seasonal AR (SAR), who came to Al Rashed Allergy Center in period from October 2014 to October 2015, obtain Nasal Smear for Eosinophils as a screening test before further diagnostic evaluation. Nasal samples were collected by passing a sterile swab, from each nasal cavity, along the medial surface of the inferior turbinate 2 to 3 times and the specimen smeared on a clear glass slide. Nasal smears were examined by light microscopy after staining with hematoxylin and eosin stain. Skin prick test is performed in all symptomatic patients with a battery of inhalant allergens that include local pollens. The control group was recruited, with their voluntary consent, from the medical stuff with a negative history of any allergic nasal symptoms. In this group we performed only nasal smear for Eosinophils. Air Biology Laboratory Kuwait provided us with daily pollen count. From total 158 study participants, 132 had SAR symptoms and are divided in four groups. Fifth, control, group is non symptomatic. For 38.6% of symptomatic patients NSE were positive, while 45% of these patients have negative SPT. From 62.1% NSE negative patients, 37.8% have negative SPT. Our results showed expected positive correlation of NSE positive patients with pollen season in Kuwait, in SPT positive group. However, presence of Eosinophils in nasal smear was moderate to high also in patients with negative SPT during the highest peak of season, in contrast to control group. NES showed moderate sensitivity, relatively high specificity and importance as screening test in SPT negative patients. Evaluation of AR demand wide and improved diagnostic approach due to significant number of SPT negative patients with positive NSE based on natural allergen stimulation. Our results emphasize locale allergic response of nasal mucosa and importance of target organ diagnostic approach.

  14. Prevalence of abnormal Pap smears in a consecutive and previously unscreened population in Romania.

    PubMed

    Stolnicu, Simona; Musca, Simona; Micu, Dorian; Micu, Luminita; Moldovan, Cosmin; Puscasiu, Lucian

    2014-02-01

    To determine the prevalence of abnormal cervical smears in a previously unscreened and asymptomatic population in Romania and to compare the data with those from other countries in Europe. In a retrospective study, data were reviewed from smears obtained from women in Romania who had been referred to the gynecologist between January 2006 and December 2011. The smears were collected through 3 regional opportunistic programs of cervical screening and were classified according to the Bethesda system. During the study period, 50536 smear tests were carried out. Of these, 100 smears (0.2%) were unsatisfactory and excluded from the study. Among the remaining 50436 smears, 2965 patients (5.9%) had abnormal epithelial changes. Most of the abnormal smears were represented by atypical squamous cells of undetermined significance (2.6% of all smears). The data confirmed that there is a high prevalence of high-grade intraepithelial squamous-type lesions (0.9% of all smears) in Romania, and of abnormal smears in women younger than 25years of age (14.0% of all abnormal smears). The data show that there is a high prevalence of epithelial abnormalities among cervical smears in Romania compared with other European countries that run a national screening program. © 2013.

  15. Watermarking on 3D mesh based on spherical wavelet transform.

    PubMed

    Jin, Jian-Qiu; Dai, Min-Ya; Bao, Hu-Jun; Peng, Qun-Sheng

    2004-03-01

    In this paper we propose a robust watermarking algorithm for 3D mesh. The algorithm is based on spherical wavelet transform. Our basic idea is to decompose the original mesh into a series of details at different scales by using spherical wavelet transform; the watermark is then embedded into the different levels of details. The embedding process includes: global sphere parameterization, spherical uniform sampling, spherical wavelet forward transform, embedding watermark, spherical wavelet inverse transform, and at last resampling the mesh watermarked to recover the topological connectivity of the original model. Experiments showed that our algorithm can improve the capacity of the watermark and the robustness of watermarking against attacks.

  16. A PARASITOLOGIC AND MOLECULAR SURVEY OF HEPATOZOON CANIS INFECTION IN STRAY DOGS IN NORTHEAST OF IRAN.

    PubMed

    Barati, Ali; Razmi, Gholamreza

    2018-05-15

    Canine hepatozoonosis, caused by H. canis, is a tick-borne disease in domestic and wild dogs that is transmitted by ingestion of Rhipicephalus sanguineus ticks. The aim of the study was to detect H. canis in stray dogs in Iran using blood smear examination and molecular techniques. From October 2014 to September 2015, 150 EDTA blood samples were collected from stray dogs in the northeast region of Iran. Blood smears were microscopically examined for the presence of Hepatozoon gamonts; whole blood was evaluated by PCR, with subsequent sequencing and phylogenetic analysis. Hepatozoon spp. Gamonts were observed in the neutrophils of 5/150 (3.3%) blood smears, whereas Hepatozoon spp. 18S rDNA was detected in 12/150 (8.0%) blood samples from stray dogs. There was a good agreement between microscopy and PCR methods. (Kappa= 0.756). The highest rate of infection was seasonally detected in the summer (p<0.05). The difference of frequency of Hepatozoon spp infection was not significant by gender and age factors (p>0.05). The alignment analysis of the sequenced samples showed ≥99% similarity with other nucleotide sequences of Hepatozoon spp. in GenBank. The phylogenetic tree also revealed that the nucleotide sequences in this study were clustered in the H. canis clade and different from the H. felis and H. americanum clades. According to the results, it is concluded that H. canis infection is present among dogs in northeastern region of Iran.

  17. Automated image processing method for the diagnosis and classification of malaria on thin blood smears.

    PubMed

    Ross, Nicholas E; Pritchard, Charles J; Rubin, David M; Dusé, Adriano G

    2006-05-01

    Malaria is a serious global health problem, and rapid, accurate diagnosis is required to control the disease. An image processing algorithm to automate the diagnosis of malaria on thin blood smears is developed. The image classification system is designed to positively identify malaria parasites present in thin blood smears, and differentiate the species of malaria. Images are acquired using a charge-coupled device camera connected to a light microscope. Morphological and novel threshold selection techniques are used to identify erythrocytes (red blood cells) and possible parasites present on microscopic slides. Image features based on colour, texture and the geometry of the cells and parasites are generated, as well as features that make use of a priori knowledge of the classification problem and mimic features used by human technicians. A two-stage tree classifier using backpropogation feedforward neural networks distinguishes between true and false positives, and then diagnoses the species (Plasmodium falciparum, P. vivax, P. ovale or P. malariae) of the infection. Malaria samples obtained from the Department of Clinical Microbiology and Infectious Diseases at the University of the Witwatersrand Medical School are used for training and testing of the system. Infected erythrocytes are positively identified with a sensitivity of 85% and a positive predictive value (PPV) of 81%, which makes the method highly sensitive at diagnosing a complete sample provided many views are analysed. Species were correctly determined for 11 out of 15 samples.

  18. Survey of Ehrlichia canis, Babesia spp. and Hepatozoon spp. in dogs from a semiarid region of Brazil.

    PubMed

    Rotondano, Tereza Emmanuelle de Farias; Almeida, Herta Karyanne Araújo; Krawczak, Felipe da Silva; Santana, Vanessa Lira; Vidal, Ivana Fernandes; Labruna, Marcelo Bahia; de Azevedo, Sérgio Santos; Ade lmeida, Alzira Maria Paiva; de Melo, Marcia Almeida

    2015-01-01

    This study assessed the occurrence of Ehrlichia spp., Babesia spp. and Hepatozoon spp. infections in 100 tick-harboring dogs from a semiarid region of the State of Paraíba, Northeastern Brazil. Blood samples and ticks were collected from the animals, and a questionnaire was submitted to dog owners to obtain general data. Blood samples were used to perform hemogram, direct blood smear and immunological and molecular hemoparasite detection. The 1,151 ticks collected were identified as Rhipicephalus sanguineus; direct smears revealed E. canis-like morulae in the monocytes of 4% (4/100) of the non-vaccinated female dogs, and 34% and 25% of the dogs tested positive for Ehrlichia canis by indirect immunofluorescence assay (IFA) and polymerase chain reaction (PCR), respectively. Blood smear examination revealed Babesia-suggestive merozoites in the erythrocytes of 2% (2/100) of the animals. Babesia vogeli was detected by PCR in ten animals (10%) and was correlated with young age (p = 0.007) and thrombocytopenia (p = 0.01). None of the animals showed Hepatozoon spp. positivity. These results indicate that E. canis is the main tick-borne canine pathogen in the study area and provide the first report of B. vogeli infection in dogs from Paraiba State.

  19. Impact of external haematology proficiency testing programme on quality of laboratories.

    PubMed

    Saxena, Renu; Katoch, S C; Srinivas, Upendra; Rao, Seema; Anand, Hema

    2007-11-01

    A reliable and reproducible report from a laboratory needs internal quality control within the laboratory and participation in external proficiency testing programmes (EPTP). This study conducted at the Department of Haematology, All India Institute of Medical Sciences (AIIMS), New Delhi, which has been conducting an EPTP since 1992, was undertaken to assess the efficacy of this programme in improving the performance of participating laboratories in reporting test samples sent for Hb, total leucocyte count (TLC), reticulocyte count and assessment of peripheral blood smear (PBS). The samples were prepared in our laboratory according to the International Standards Organization (ISO) guidelines. The performance of individual laboratories was assessed using robust Z score, which is an indicator of acceptability of the test result. An improvement in the overall percentage of laboratories with acceptable reports was seen during the study period. It has increased from 38,40,40 per cent in 1992 to 85, 90,94.7 per cent in 2006 for Hb, TLC, reticulocyte count, respectively. However, the results for peripheral smear assessment improved only marginally. The external haematology proficiency testing programme run by our department for Hb, TLC, reticulocyte count, and peripheral blood smear assessment, has helped in improving the reporting standards of these parameters in Indian laboratories.

  20. Fluid intake from beverages across age groups: a systematic review.

    PubMed

    Özen, A E; Bibiloni, M Del Mar; Pons, A; Tur, J A

    2015-10-01

    Fluid intake, especially water, is essential for human life and also necessary for physical and mental function. The present study aimed to assess beverage consumption across age groups. A systematic review was conducted. Original research in English language publications and available studies (or abstracts in English) from 2000 to 2013 was searched for by using the medical subheading (MeSH) terms: ('beverage' OR 'fluid' [Major]) AND ('consumption' [Mesh] OR 'drinking' [Mesh] OR 'intake' [Mesh]) AND ('child' [Mesh] OR 'adolescent' [Mesh] OR 'adult' [Mesh]). Article selection was restricted to those papers covering healthy populations of all age groups in a nationwide sample, or from a representative sample of the population of a city or cities, which examined the trends or patterns of beverage intake and the determinants of beverage intake. Sixty-five studies were identified with respect to beverage consumption across age groups. The papers were screened by thoroughly reading titles or abstracts. Full-text articles were assessed by three investigators. Total beverage intake varied between 0.6 and 3.5 L day(-1) among all age groups (males more than females). Plain water contributed up to 58%, 75% and 80% of the total beverage intake in children, adolescents and adults, respectively. Milk consumption was higher among children; consumption of soft drinks was higher among adolescents; and the consumption of tea, coffee and alcoholic beverages was higher among adults. Plain water is the main water source for all age groups and the consumption of other beverages varies according to age. © 2014 The British Dietetic Association Ltd.

  1. A hybrid multiview stereo algorithm for modeling urban scenes.

    PubMed

    Lafarge, Florent; Keriven, Renaud; Brédif, Mathieu; Vu, Hoang-Hiep

    2013-01-01

    We present an original multiview stereo reconstruction algorithm which allows the 3D-modeling of urban scenes as a combination of meshes and geometric primitives. The method provides a compact model while preserving details: Irregular elements such as statues and ornaments are described by meshes, whereas regular structures such as columns and walls are described by primitives (planes, spheres, cylinders, cones, and tori). We adopt a two-step strategy consisting first in segmenting the initial meshbased surface using a multilabel Markov Random Field-based model and second in sampling primitive and mesh components simultaneously on the obtained partition by a Jump-Diffusion process. The quality of a reconstruction is measured by a multi-object energy model which takes into account both photo-consistency and semantic considerations (i.e., geometry and shape layout). The segmentation and sampling steps are embedded into an iterative refinement procedure which provides an increasingly accurate hybrid representation. Experimental results on complex urban structures and large scenes are presented and compared to state-of-the-art multiview stereo meshing algorithms.

  2. Efficiency of the Lung Flute for sputum induction in patients with presumed pulmonary tuberculosis.

    PubMed

    Sakashita, Kentaro; Fujita, Akira; Takamori, Mikio; Nagai, Takayuki; Matsumoto, Tomoshige; Saito, Takefumi; Nakagawa, Taku; Ogawa, Kenji; Shigeto, Eriko; Nakatsumi, Yasuto; Goto, Hajime; Mitarai, Satoshi

    2018-04-01

    High quality sputum helps increase the sensitivity of the diagnosis of pulmonary tuberculosis. To evaluate the efficiency of the acoustic device (Lung Flute; LF) in sputum induction compared with the conventional method, hypertonic saline inhalation (HSI). In this crossover study, patients with presumed pulmonary tuberculosis submitted 3 consecutive sputa: the first sputum without induction and the second and third ones using LF and HSI. We compared the efficiency of the 2 induction methods. Sixty-four participants were eligible. Thirty-five (54.6%) patients had negative smears on the first sputum without induction. Among those patients, 25.7% and 22.9% patients were smear-positive after using LF and HSI, respectively (P = .001). The positive conversion rate was not significantly different between the methods. The first samples without induction yielded 65.7% positive cultures, whereas 71.4% and 77.1% of the samples from LF and HSI were positive, respectively (P = .284). Similar results were observed in the nucleic acid amplification test [no induction (60.0%), LF (72.0%) and HSI (60.0%); P = .341]. In 29 smear-positive patients on the first sputum without induction, we observed no significant increase in smear grade, culture yield and nucleic acid amplification test positivity with either method. LF tended to induce fewer adverse events; desaturation (3.1% vs 11.1%; P = .082) and throat pain (1.5% vs 9.5%; P = .057). LF showed significantly fewer total adverse events (15.8% vs 34.9%; P = .023). Our study showed LF had similar sputum induction efficiency to HSI with relatively fewer complications. © 2017 The Authors. The Clinical Respiratory Journal Published by John Wiley & Sons Ltd.

  3. Monogenean parasites from fishes of the Vaal Dam, Gauteng Province, South Africa II. New locality records.

    PubMed

    Crafford, Dionne; Luus-Powell, Wilmien; Avenant-Oldewage, Annemariè

    2014-09-01

    Baseline information on parasitic infections, including monogenean infections on wild fishes, may aid in implementation of proactive measures as opposed to reactive research aimed at crisis control with reference to future aquaculture applications. The aim of this project was to examine the freshwater monogenean fauna of the Vaal Dam, Vaal River system, South Africa. This short communication reports on infection statistics for monogenean species, some representing new locality records. Parasites were collected from host species other than Labeo spp. from the Vaal Dam, during a summer (January 2010) survey. Fish collected using gill nets of varying mesh sizes were weighed and measured. Mucous smears were prepared from the skin and fins with the aid of microscope slides. Fish were killed humanely by severing the spinal cord behind the head. Gills were carefully removed and divided into areas which were separately scraped to investigate potential parasite site preference. The areas examined were dorsal, median and ventral positions on both the anterior and posterior hemibranch. Both mucous smears and gill scrapings were examined with the aid of a stereo microscope. More parasites were collected from the first or second gill arches, the medial position on the gill, and the anterior hemibranch. Preference for either left or right gill set was inconclusive. Spatial distribution of parasites is thought to result from water flow over the gills during respiration. This paper reports a new locality record for the following monogenean species: Quadriacanthus aegypticus, Dactylogyrus extensus, Dactylogyrus minitus, Gyrodactylus kherulensis and Dactylogyrus lamellatus.

  4. Significance of the Cytological Signs of Human Papillomavirus Infection in Anal Pap Smears of Human Immunodeficiency Virus-Infected Japanese Men Who Have Sex with Men

    PubMed

    Okayama, Kaori; Okodo, Mitsuaki; Kitamura, Hiroshi; Itoda, Ichiro

    2017-11-26

    Purpose: The incidence of invasive anal cancer (IAC) has been increasing among human immunodeficiency virus (HIV)-positive men who have sex with men (MSM). Although cytological diagnosis is the modality of choice for screening cases of IAC, it is associated with lower sensitivity and specificity. Therefore, the present study aimed to evaluate new cytological signs of human papillomavirus (HPV) infection that may contribute to improving anal cytology. Methods: Anal cytology and HPV testing were performed using SurePath liquid-based cytology on samples obtained from 37 HIV-positive Japanese MSM. Subsequently, a histological biopsy based on high-resolution anoscopy was performed in MSM with abnormal cytological findings indicative of atypical squamous cells of undetermined significance (ASC-US) +. Also, anal Papanicolaou (Pap) smears were performed to determine cellularity, presence of dysplastic squamous cells, and other cytological signs of HPV infection. Results: Of the 37 MSM who underwent anal cytology, six tested negative for intraepithelial lesion or malignancy, three cases exhibited ASC-US, 17 exhibited low-grade squamous intraepithelial lesion (LSIL), nine exhibited high-grade squamous intraepithelial lesion (HSIL), and two remained undiagnosed. The anal Pap smears of 28 (96.6%) of the 29 MSM with abnormal cytological findings of ASC-US+ exhibited anal intraepithelial neoplasia (AIN), as revealed by histological biopsy. The median value (minimum–maximum) of the cellularity of anal Pap smears was 12 (0–70.5) nsc/hpf. In 26 MSM with LSIL and HSIL, the median dysplastic squamous cells count was 14 (2–152) dsc/smear and the cytological sign of HPV infection was 11 (2–71) hpv/smear. Of all anal Pap smears that revealed ASC-US+, 96.6% exhibited cytological signs of HPV infection. Compression-positive binucleated cells were the most prevalent among all cytological signs of HPV infection. Conclusion: For anal cytology, instead of considering a small number of dysplastic squamous cells, screening based on cytological signs of HPV infection may be beneficial for improving the diagnosis of AIN. Creative Commons Attribution License

  5. Mechanical behaviour of synthetic surgical meshes: finite element simulation of the herniated abdominal wall.

    PubMed

    Hernández-Gascón, B; Peña, E; Melero, H; Pascual, G; Doblaré, M; Ginebra, M P; Bellón, J M; Calvo, B

    2011-11-01

    The material properties of meshes used in hernia surgery contribute to the overall mechanical behaviour of the repaired abdominal wall. The mechanical response of a surgical mesh has to be defined since the haphazard orientation of an anisotropic mesh can lead to inconsistent surgical outcomes. This study was designed to characterize the mechanical behaviour of three surgical meshes (Surgipro®, Optilene® and Infinit®) and to describe a mechanical constitutive law that accurately reproduces the experimental results. Finally, through finite element simulation, the behaviour of the abdominal wall was modelled before and after surgical mesh implant. Uniaxial loading of mesh samples in two perpendicular directions revealed the isotropic response of Surgipro® and the anisotropic behaviour of Optilene® and Infinit®. A phenomenological constitutive law was used to reproduce the measured experimental curves. To analyze the mechanical effect of the meshes once implanted in the abdomen, finite element simulation of the healthy and partially herniated repaired rabbit abdominal wall served to reproduce wall behaviour before and after mesh implant. In all cases, maximal displacements were lower and maximal principal stresses higher in the implanted abdomen than the intact wall model. Despite the fact that no mesh showed a behaviour that perfectly matched that of abdominal muscle, the Infinit® mesh was able to best comply with the biomechanics of the abdominal wall. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  6. Early biocompatibility of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral hernia repair.

    PubMed

    Melman, L; Jenkins, E D; Hamilton, N A; Bender, L C; Brodt, M D; Deeken, C R; Greco, S C; Frisella, M M; Matthews, B D

    2011-04-01

    Biologic meshes have unique physical properties as a result of manufacturing techniques such as decellularization, crosslinking, and sterilization. The purpose of this study is to directly compare the biocompatibility profiles of five different biologic meshes, AlloDerm(®) (non-crosslinked human dermal matrix), PeriGuard(®) (crosslinked bovine pericardium), Permacol(®) (crosslinked porcine dermal matrix), Strattice(®) (non-crosslinked porcine dermal matrix), and Veritas(®) (non-crosslinked bovine pericardium), using a porcine model of ventral hernia repair. Full-thickness fascial defects were created in 20 Yucatan minipigs and repaired with the retromuscular placement of biologic mesh 3 weeks later. Animals were euthanized at 1 month and the repair sites were subjected to tensile testing and histologic analysis. Samples of unimplanted (de novo) meshes and native porcine abdominal wall were also analyzed for their mechanical properties. There were no significant differences in the biomechanical characteristics between any of the mesh-repaired sites at 1 month postimplantation or between the native porcine abdominal wall without implanted mesh and the mesh-repaired sites (P > 0.05 for all comparisons). Histologically, non-crosslinked materials exhibited greater cellular infiltration, extracellular matrix (ECM) deposition, and neovascularization compared to crosslinked meshes. While crosslinking differentiates biologic meshes with regard to cellular infiltration, ECM deposition, scaffold degradation, and neovascularization, the integrity and strength of the repair site at 1 month is not significantly impacted by crosslinking or by the de novo strength/stiffness of the mesh.

  7. Vibration-based angular speed estimation for multi-stage wind turbine gearboxes

    NASA Astrophysics Data System (ADS)

    Peeters, Cédric; Leclère, Quentin; Antoni, Jérôme; Guillaume, Patrick; Helsen, Jan

    2017-05-01

    Most processing tools based on frequency analysis of vibration signals are only applicable for stationary speed regimes. Speed variation causes the spectral content to smear, which encumbers most conventional fault detection techniques. To solve the problem of non-stationary speed conditions, the instantaneous angular speed (IAS) is estimated. Wind turbine gearboxes however are typically multi-stage gearboxes, consisting of multiple shafts, rotating at different speeds. Fitting a sensor (e.g. a tachometer) to every single stage is not always feasible. As such there is a need to estimate the IAS of every single shaft based on the vibration signals measured by the accelerometers. This paper investigates the performance of the multi-order probabilistic approach for IAS estimation on experimental case studies of wind turbines. This method takes into account the meshing orders of the gears present in the system and has the advantage that a priori it is not necessary to associate harmonics with a certain periodic mechanical event, which increases the robustness of the method. It is found that the MOPA has the potential to easily outperform standard band-pass filtering techniques for speed estimation. More knowledge of the gearbox kinematics is beneficial for the MOPA performance, but even with very little knowledge about the meshing orders, the MOPA still performs sufficiently well to compete with the standard speed estimation techniques. This observation is proven on two different data sets, both originating from vibration measurements on the gearbox housing of a wind turbine.

  8. 3-D inversion of airborne electromagnetic data parallelized and accelerated by local mesh and adaptive soundings

    NASA Astrophysics Data System (ADS)

    Yang, Dikun; Oldenburg, Douglas W.; Haber, Eldad

    2014-03-01

    Airborne electromagnetic (AEM) methods are highly efficient tools for assessing the Earth's conductivity structures in a large area at low cost. However, the configuration of AEM measurements, which typically have widely distributed transmitter-receiver pairs, makes the rigorous modelling and interpretation extremely time-consuming in 3-D. Excessive overcomputing can occur when working on a large mesh covering the entire survey area and inverting all soundings in the data set. We propose two improvements. The first is to use a locally optimized mesh for each AEM sounding for the forward modelling and calculation of sensitivity. This dedicated local mesh is small with fine cells near the sounding location and coarse cells far away in accordance with EM diffusion and the geometric decay of the signals. Once the forward problem is solved on the local meshes, the sensitivity for the inversion on the global mesh is available through quick interpolation. Using local meshes for AEM forward modelling avoids unnecessary computing on fine cells on a global mesh that are far away from the sounding location. Since local meshes are highly independent, the forward modelling can be efficiently parallelized over an array of processors. The second improvement is random and dynamic down-sampling of the soundings. Each inversion iteration only uses a random subset of the soundings, and the subset is reselected for every iteration. The number of soundings in the random subset, determined by an adaptive algorithm, is tied to the degree of model regularization. This minimizes the overcomputing caused by working with redundant soundings. Our methods are compared against conventional methods and tested with a synthetic example. We also invert a field data set that was previously considered to be too large to be practically inverted in 3-D. These examples show that our methodology can dramatically reduce the processing time of 3-D inversion to a practical level without losing resolution. Any existing modelling technique can be included into our framework of mesh decoupling and adaptive sampling to accelerate large-scale 3-D EM inversions.

  9. Prevalence of Sarcocystis infection in processed meat products by using digestion and impression smear methods in Hamedan, Iran.

    PubMed

    Dehkordi, Zainab Sadeghi; Yalameha, Banafsheh; Sari, Abbas Ali

    2017-01-01

    Sarcocystis is a common zoonotic parasite which can be transmitted through ingestion of contaminated, undercooked meat and is a major cause of economic loss in many countries. This study aimed to detect Sarcocystis parasite in processed meat products in Hamedan, Iran. A total of 20 samples of hamburger, sausage, and cocktail were collected from markets from three factories in Hamedan, Iran. The samples were examined by digestion and impression smear methods for detecting Sarcocystis parasite. The results showed that 80% of all tested samples were infected with Sarcocystis . The infection rate in hamburger, sausage, and cocktail were 87.5, 83.33, and 66.66%, respectively. The highest infestation rate was observed in hamburger. The present study shows that the rate of Sarcocystis contamination in meat products is very high. So, evaluation of raw meat quality in addition to applying hygienic programs at all stages of the production line is inevitable. Also, consumption of undercooked meat products or fast food should be avoided.

  10. Interphase cytogenetics of prostatic carcinoma in fine needle aspirate smears of radical prostatectomy specimens: A practical screening tool?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, R.Y.; Troncoso, P.; El-Naggar, A.K.

    1994-09-01

    Identification of chromosomal aberrations that may be used for diagnostic or prognostic evaluation of prostatic adenocarcinoma has been the subject of great interest. In a previous study, we applied the fluorescence in situ hybridization (FISH) method on paraffin-embedded material to show that trisomy 7 was associated with the progression of human prostate cancer. In this study, we attempted to assess the utility of the FISH technique in detecting aneuploidy in fine needle aspirate (FNA) smears of prostatic tissues and to compare FISH results with that of DNA flow cytometry (FCM). Paired samples of normal and tumor FNA smears were obtainedmore » from 10 radical prostatectomy specimens. Dual-color chromosomes 7 and 9-specific centromeric DNA probes were used for FISH. FISH analysis demonstrated increased frequencies of trisomy 7 cells in all 10 tumors studied when compared with the paired normals. In contrast, 6 of 10 tumors were determined to be diploid by FCM. Our results show that FNA of radical prostatectomy specimens is a practical method for obtaining suitable material for both FISH and FCM analyses of prostate carcinoma. Thus, interphase FISH may be a practical screening tool to determine aneuploidy in FNA smears of prostatic carcinoma.« less

  11. Effects of pre-analytical variables on flow cytometric diagnosis of canine lymphoma: A retrospective study (2009-2015).

    PubMed

    Comazzi, S; Cozzi, M; Bernardi, S; Zanella, D R; Aresu, L; Stefanello, D; Marconato, L; Martini, V

    2018-02-01

    Flow cytometry (FC) is increasingly being used for immunophenotyping and staging of canine lymphoma. The aim of this retrospective study was to assess pre-analytical variables that might influence the diagnostic utility of FC of lymph node (LN) fine needle aspirate (FNA) specimens from dogs with lymphoproliferative diseases. The study included 987 cases with LN FNA specimens sent for immunophenotyping that were submitted to a diagnostic laboratory in Italy from 2009 to 2015. Cases were grouped into 'diagnostic' and 'non-diagnostic'. Pre-analytical factors analysed by univariate and multivariate analyses were animal-related factors (breed, age, sex, size), operator-related factors (year, season, shipping method, submitting veterinarian) and sample-related factors (type of sample material, cellular concentration, cytological smears, artefacts). The submitting veterinarian, sample material, sample cellularity and artefacts affected the likelihood of having a diagnostic sample. The availability of specimens from different sites and of cytological smears increased the odds of obtaining a diagnostic result. Major artefacts affecting diagnostic utility included poor cellularity and the presence of dead cells. Flow cytometry on LN FNA samples yielded conclusive results in more than 90% of cases with adequate sample quality and sampling conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Ultra-small-angle neutron scattering with azimuthal asymmetry

    DOE PAGES

    Gu, X.; Mildner, D. F. R.

    2016-05-16

    Small-angle neutron scattering (SANS) measurements from thin sections of rock samples such as shales demand as great a scattering vector range as possible because the pores cover a wide range of sizes. The limitation of the scattering vector range for pinhole SANS requires slit-smeared ultra-SANS (USANS) measurements that need to be converted to pinhole geometry. The desmearing algorithm is only successful for azimuthally symmetric data. Scattering from samples cut parallel to the plane of bedding is symmetric, exhibiting circular contours on a two-dimensional detector. Samples cut perpendicular to the bedding show elliptically dependent contours with the long axis corresponding tomore » the normal to the bedding plane. A method is given for converting such asymmetric data collected on a double-crystal diffractometer for concatenation with the usual pinhole-geometry SANS data. Furthermore, the aspect ratio from the SANS data is used to modify the slit-smeared USANS data to produce quasi-symmetric contours. Rotation of the sample about the incident beam may result in symmetric data but cannot extract the same information as obtained from pinhole geometry.« less

  13. Ultra-small-angle neutron scattering with azimuthal asymmetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gu, X.; Mildner, D. F. R.

    Small-angle neutron scattering (SANS) measurements from thin sections of rock samples such as shales demand as great a scattering vector range as possible because the pores cover a wide range of sizes. The limitation of the scattering vector range for pinhole SANS requires slit-smeared ultra-SANS (USANS) measurements that need to be converted to pinhole geometry. The desmearing algorithm is only successful for azimuthally symmetric data. Scattering from samples cut parallel to the plane of bedding is symmetric, exhibiting circular contours on a two-dimensional detector. Samples cut perpendicular to the bedding show elliptically dependent contours with the long axis corresponding tomore » the normal to the bedding plane. A method is given for converting such asymmetric data collected on a double-crystal diffractometer for concatenation with the usual pinhole-geometry SANS data. Furthermore, the aspect ratio from the SANS data is used to modify the slit-smeared USANS data to produce quasi-symmetric contours. Rotation of the sample about the incident beam may result in symmetric data but cannot extract the same information as obtained from pinhole geometry.« less

  14. Effects of mesenchymal stem cell and fibroblast coating on immunogenic potential of prosthetic meshes in vitro.

    PubMed

    Gao, Yue; Krpata, David M; Criss, Cory N; Liu, Lijia; Posielski, Natasza; Rosen, Michael J; Novitsky, Yuri W

    2014-08-01

    The aim of this study was to reveal the effect of fibroblast or mesenchymal stem cell (MSC) coating on the mesh-induced production of IL-1β, IL-6, and VEGF by macrophages. Four commonly used surgical meshes were tested in this study, including Parietex, SoftMesh, TIGR, and Strattice. One-square-centimeter pieces of each mesh were placed on top of a monolayer of human fibroblasts or rat MSCs. The coating status was monitored with a light microscope. The human promonocytic cell line U937 was induced to differentiate into macrophages (MΦ). Three weeks later, meshes were transferred to new 24-well plates and cocultured with the MΦs for 72 h. Culture medium was collected and analyzed for IL-1β, IL-6, and VEGF production using standard ELISA essays. Parallel mesh samples were fixed with paraformaldehyde or glutaraldehyde for histology or transmission electronic microscopy (TEM) analyses, respectively. Uncoated meshes induced increased production of all three cytokines compared with macrophages cultured alone. HF coating further increased the production of both IL-6 and VEGF but reduced IL-1β production. Except for the SoftMesh group, MSC coating significantly blunted release of all cytokines to levels even lower than with MΦs cultured alone. MΦs tended to deteriorate in the presence of MSCs. Both histology and TEM revealed intimate interactions between cell-coated meshes and MΦs. Cytokine response to fibroblast coating varied, while MSC coating blunted the immunogenic effect of both synthetic and biologic meshes in vitro. Cell coating appears to affect mesh biocompatibility and may become a key process in mesh evolution.

  15. Methanethiol Concentrations and Sea-Air Fluxes in the Subarctic NE Pacific Ocean

    NASA Astrophysics Data System (ADS)

    Kiene, R. P.; Williams, T. E.; Esson, K.; Tortell, P. D.; Dacey, J. W. H.

    2017-12-01

    Exchange of volatile organic sulfur from the ocean to the atmosphere impacts the global sulfur cycle and the climate system and is thought to occur mainly via the gas dimethylsulfide (DMS). DMS is produced during degradation of the abundant phytoplankton osmolyte dimethylsulfoniopropionate (DMSP) but bacteria can also convert dissolved DMSP into the sulfur gas methanethiol (MeSH). MeSH has been difficult to measure in seawater because of its high chemical and biological reactivity and, thus, information on MeSH concentrations, distribution and sea-air fluxes is limited. We measured MeSH in the northeast subarctic Pacific Ocean in July 2016, along transects with strong phytoplankton abundance gradients. Water samples obtained with Niskin bottles were analyzed for MeSH by purge-and-trap gas chromatography. Depth profiles showed that MeSH concentrations were high near the surface and declined with depth. Surface waters (5 m depth) had an average MeSH concentration of 0.75 nM with concentrations reaching up to 3nM. MeSH concentrations were correlated (r = 0.47) with microbial turnover of dissolved DMSP which ranged up to 236 nM per day. MeSH was also correlated with total DMSP (r = 0.93) and dissolved DMS (r = 0.63), supporting the conclusion that DMSP was a major precursor of MeSH. Surface water MeSH:DMS concentration ratios averaged 0.19 and ranged up to 0.50 indicating that MeSH was a significant fraction of the volatile sulfur pool in surface waters. Sea-air fluxes of MeSH averaged 15% of the combined DMS+MeSH flux, therefore MeSH contributed an important fraction of the sulfur emitted to the atmosphere from the subarctic NE Pacific Ocean.

  16. Effect of cost-sharing reductions on preventive service use among Medicare fee-for-service beneficiaries.

    PubMed

    Goodwin, Suzanne M; Anderson, Gerard F

    2012-01-01

    Section 4104 of the Patient Protection and Affordable Care Act (ACA) waives previous cost-sharing requirements for many Medicare-covered preventive services. In 1997, Congress passed similar legislation waiving the deductible only for mammograms and Pap smears. The purpose of this study is to examine the effect of the deductible waiver on mammogram and Pap smear utilization rates. Using 1995-2003 Medicare claims from a sample of female, elderly Medicare fee-for-service beneficiaries, two pre/post analyses were conducted comparing mammogram and Pap smear utilization rates before and after implementation of the deductible waiver. Receipt of screening mammograms and Pap smears served as the outcome measures, and two time measures, representing two post-test observation periods, were used to examine the short- and long-term impacts on utilization. There was a 20 percent short-term and a 25 percent longer term increase in the probability of having had a mammogram in the four years following the 1997 deductible waiver. Beneficiaries were no more likely to receive a Pap smear following the deductible waiver. Elimination of cost sharing may be an effective strategy for increasing preventive service use, but the impact could depend on the characteristics of the procedure, its cost, and the disease and populations it targets. These historical findings suggest that, with implementation of Section 4104, the greatest increases in utilization will be seen for preventive services that screen for diseases with high incidence or prevalence rates that increase with age, that are expensive, and that are performed on a frequent basis.

  17. Evaluation of FASTPlaqueTB to diagnose smear-negative tuberculosis in a peripheral clinic in Kenya.

    PubMed

    Bonnet, M; Gagnidze, L; Varaine, F; Ramsay, A; Githui, W; Guerin, P J

    2009-09-01

    To evaluate the performance and feasibility of FASTPlaqueTB in smear-negative tuberculosis (TB) suspects in a peripheral clinic after laboratory upgrading. Patients with cough > or=2 weeks, two sputum smear-negative results, no response to 1 week of amoxicillin and abnormal chest X-ray were defined as smear-negative suspects. One sputum sample was collected, decontaminated and divided into two: half was tested with FASTPlaqueTB in the clinic laboratory and the other half was cultured on Löwenstein-Jensen medium in the Kenyan Medical Research Institute. Test sensitivity and specificity were evaluated in all patients and in human immunodeficiency virus (HIV) infected patients. Feasibility was assessed by the contamination rate and the resources required to upgrade the laboratory. Of 208 patients included in the study, 56.2% were HIV-infected. Of 203 FASTPlaqueTB tests, 95 (46.8%) were contaminated, which interfered with result interpretation and led to the interruption of the study. Sensitivity and specificity were respectively 31.2% (95%CI 12.1-58.5) and 94.9% (95%CI 86.8-98.4) in all patients and 33.3% (95%CI 9.9-65.1) and 93.9% (95%CI 83.1-98.7) in HIV-infected patients. Upgrading the laboratory cost euro 20,000. FASTPlaqueTB did not perform satisfactorily in this setting. If contamination can be reduced, in addition to laboratory upgrading, its introduction in peripheral clinics would require further assessment in smear-negative and HIV co-infected patients and test adaptation for friendlier use.

  18. Balancing uncertainty and acceptance: understanding Chinese women's responses to an abnormal cervical smear result.

    PubMed

    Twinn, Sheila

    2006-09-01

    The aims of this study were to examine the responses of Hong Kong Chinese women receiving an abnormal smear result and to compare any differences in responses depending on the diagnosis of the abnormal smear. The implementation of cervical screening programmes has resulted in an increasing number of women receiving an abnormal smear result requiring cytological surveillance or referral for colposcopy. Evidence suggests that women frequently misunderstood such results, believing that they already have cancer. However, little is known about the responses of Chinese women in this situation. An exploratory qualitative study. Face-to-face semi-structured tape-recorded interviews were undertaken with 66 women sampled opportunistically from an urban centre of a major non-governmental service provider. Amongst this sample, 22 women required cytological surveillance, 20 required treatment for vaginitis and 24 were referred for colposcopy. Thematic analysis was undertaken of the translated interviews within and across groups to identify categories and themes illustrating women's responses to an abnormal smear result. An important difference in the comparison of the data sets was that of women's understanding of the cause of the abnormal result. Women with vaginitis understood the cause of their abnormality, whereas those in the other groups remained unclear about their abnormality, generating feelings of fear and uncertainty. Trust in practitioners influenced women's acceptance of the result. Although responses of Chinese women are similar to those in other population groups, with those referred for colposcopy experiencing greater anxiety than those undergoing cytological surveillance, balancing feelings of uncertainty and acceptance influenced Chinese women's responses to their abnormal results and allowed them to make sense of their result in their everyday life. Trust in the practitioner was essential to the acceptance of their result. Such findings highlight implications for nursing practice, in particular developing information-giving strategies and targeted information to help women manage feelings of uncertainty. The importance of trusting professional relationships in determining women's acceptance of an abnormal result is also highlighted. The findings suggest nurses working with Chinese women should consider the underlying influence of culture on women's beliefs and actions.

  19. Perivascular epithelioid cell tumor of the uterine cervix identified on a conventional cervical smear.

    PubMed

    Tajima, Shogo; Koda, Kenji

    2015-12-01

    Perivascular epithelioid cell tumors (PEComas) most frequently involve the uterus, particularly the uterine corpus and very occasionally the cervix. One case of PEComa identified using a conventional cervical smear has previously been documented. Herein, we present the second such case. The patient was a 51-year-old woman with abnormal genital tract bleeding. Samples collected for conventional cervical smears were submitted for cytopathological examination, which revealed discohesive monotonous tumor cells showing epithelioid morphology, ample cytoplasm that was pale to weakly eosinophilic, and mildly enlarged nuclei. The cytopathological features were well correlated with histopathological findings. Upon immunohistochemistry, the tumor cells were positive for both melanocytic and smooth muscle markers. Based on these findings, PEComa was diagnosed. Subsequently, a total hysterectomy with bilateral salpingo-oophorectomy was performed, revealing that the tumor (28 × 22 × 12 mm) was located at the superficial part of the endocervix. We propose that the cytopathological findings described herein can guide the diagnosis of PEComa, even though this tumor is rare. © 2015 Wiley Periodicals, Inc.

  20. Comparative study of Gram stain, potassium hydroxide smear, culture and nested PCR in the diagnosis of fungal keratitis.

    PubMed

    Badiee, Parisa; Nejabat, Mahmood; Alborzi, Abdolvahab; Keshavarz, Fatemeh; Shakiba, Elaheh

    2010-01-01

    This study seeks to evaluate the efficacy and practicality of the molecular method, compared to the standard microbiological techniques for diagnosing fungal keratitis (FK). Patients with eye findings suspected of FK were enrolled for cornea sampling. Scrapings from the affected areas of the infected corneas were obtained and were divided into two parts: one for smears and cultures, and the other for nested PCR analysis. Of the 38 eyes, 28 were judged to have fungal infections based on clinical and positive findings in the culture, smear and responses to antifungal treatment. Potassium hydroxide, Gram staining, culture and nested PCR results (either positive or negative) matched in 76.3, 42.1, 68.4 and 81.6%, respectively. PCR is a sensitive method but due to the lack of sophisticated facilities in routine laboratory procedures, it can serve only complementarily and cannot replace conventional methods. Copyright © 2010 S. Karger AG, Basel.

  1. Customization of Advia 120 thresholds for canine erythrocyte volume and hemoglobin concentration, and effects on morphology flagging results.

    PubMed

    Grimes, Carolyn N; Fry, Michael M

    2014-12-01

    This study sought to develop customized morphology flagging thresholds for canine erythrocyte volume and hemoglobin concentration [Hgb] on the ADVIA 120 hematology analyzer; compare automated morphology flagging with results of microscopic blood smear evaluation; and examine effects of customized thresholds on morphology flagging results. Customized thresholds were determined using data from 52 clinically healthy dogs. Blood smear evaluation and automated morphology flagging results were correlated with mean cell volume (MCV) and cellular hemoglobin concentration mean (CHCM) in 26 dogs. Customized thresholds were applied retroactively to complete blood (cell) count (CBC) data from 5 groups of dogs, including a reference sample group, clinical cases, and animals with experimentally induced iron deficiency anemia. Automated morphology flagging correlated more highly with MCV or CHCM than did blood smear evaluation; correlation with MCV was highest using customized thresholds. Customized morphology flagging thresholds resulted in more sensitive detection of microcytosis, macrocytosis, and hypochromasia than default thresholds.

  2. Using an Adjoint Approach to Eliminate Mesh Sensitivities in Computational Design

    NASA Technical Reports Server (NTRS)

    Nielsen, Eric J.; Park, Michael A.

    2006-01-01

    An algorithm for efficiently incorporating the effects of mesh sensitivities in a computational design framework is introduced. The method is based on an adjoint approach and eliminates the need for explicit linearizations of the mesh movement scheme with respect to the geometric parameterization variables, an expense that has hindered practical large-scale design optimization using discrete adjoint methods. The effects of the mesh sensitivities can be accounted for through the solution of an adjoint problem equivalent in cost to a single mesh movement computation, followed by an explicit matrix-vector product scaling with the number of design variables and the resolution of the parameterized surface grid. The accuracy of the implementation is established and dramatic computational savings obtained using the new approach are demonstrated using several test cases. Sample design optimizations are also shown.

  3. Using an Adjoint Approach to Eliminate Mesh Sensitivities in Computational Design

    NASA Technical Reports Server (NTRS)

    Nielsen, Eric J.; Park, Michael A.

    2005-01-01

    An algorithm for efficiently incorporating the effects of mesh sensitivities in a computational design framework is introduced. The method is based on an adjoint approach and eliminates the need for explicit linearizations of the mesh movement scheme with respect to the geometric parameterization variables, an expense that has hindered practical large-scale design optimization using discrete adjoint methods. The effects of the mesh sensitivities can be accounted for through the solution of an adjoint problem equivalent in cost to a single mesh movement computation, followed by an explicit matrix-vector product scaling with the number of design variables and the resolution of the parameterized surface grid. The accuracy of the implementation is established and dramatic computational savings obtained using the new approach are demonstrated using several test cases. Sample design optimizations are also shown.

  4. Gardnerella vaginalis and Lactobacillus sp in liquid-based cervical samples in healthy and disturbed vaginal flora using cultivation-independent methods.

    PubMed

    Klomp, Johanna M; Verbruggen, Banut-Sabine M; Korporaal, Hans; Boon, Mathilde E; de Jong, Pauline; Kramer, Gerco C; van Haaften, Maarten; Heintz, A Peter M

    2008-05-01

    Our objective was to determine the morphotype of the adherent bacteria in liquid-based cytology (LBC) in smears with healthy and disturbed vaginal flora. And to use PCR technology on the same fixed cell sample to establish DNA patterns of the 16S RNA genes of the bacteria in the sample. Thirty samples were randomly selected from a large group of cervical cell samples suspended in a commercial coagulant fixative "(BoonFix)." PCR was used to amplify DNA of five bacterial species: Lactobacillus acidophilus, Lactobacillus crispatus, Lactobacillus jensenii, Gardnerella vaginalis, and Mycoplasma hominis. The LBC slides were then analyzed by light microscopy to estimate bacterial adhesion. DNA of lactobacilli was detected in all cell samples. Seventeen smears showed colonization with Gardnerella vaginalis (range 2.6 x 10(2)-3.0 x 10(5) bacteria/mul BoonFix sample). Two cases were identified as dysbacteriotic with high DNA values for Gardnerella vaginalis and low values for Lactobacillus crispatus. The sample with the highest concentration for Gardnerella vaginalis showed an unequivocal Gardnerella infection. This study indicates that the adherence pattern of a disturbed flora in liquid-based cervical samples can be identified unequivocally, and that these samples are suitable for quantitative PCR analysis. This cultivation independent method reveals a strong inverse relationship between Gardnerella vaginalis and Lactobacillus crispatus in dysbacteriosis and unequivocal Gardnerella infection.

  5. The Role of the Surgeon on Outcomes of Vaginal Prolapse Surgery With Mesh.

    PubMed

    Eilber, Karyn S; Alperin, Marianna; Khan, Aqsa; Wu, Ning; Pashos, Chris L; Clemens, J Quentin; Anger, Jennifer T

    Adverse outcomes after surgery for pelvic organ prolapse (POP) with mesh are often attributed to the mesh material with little attention paid to the influence of surgeon factors. We used a national data set to determine whether surgeon case volume and specialty influenced vaginal prolapse surgery outcomes with mesh. Public Use File data on a 5% random national sample of female Medicare beneficiaries were obtained from the Centers for Medicare and Medicaid Services. Women with a diagnosis of POP who underwent surgery with mesh between 2007 and 2008 were identified by relevant International Classification of Diseases, 9th Revision, Clinical Modification and Current Procedural Terminology, 4th Edition procedure codes. Outcomes were compared by surgeon case volume and specialty. From 2007 to 2008, 1657 surgeries for POP were performed with mesh. Low-, intermediate-, and high-volume surgeons performed 881 (53%), 408 (25%), and 368 (22%) of the cases with mesh, respectively. The cumulative reoperation rates for low-, intermediate-, and high-volume providers were 6%, 2%, and 3%, respectively. The difference in reoperation rates between low and intermediate and low- and high-volume surgeons was statistically significant (P = 0.007 and 0.003, respectively). There was no significant difference in reoperation rates between gynecologists and urologists when vaginal mesh was implanted for POP surgery. Low-volume surgeons performed most of the vaginal prolapse repairs with mesh and had significantly higher reoperation rates. Surgeon experience must be a consideration when reporting mesh-related complications of POP surgery.

  6. Co-infection with arthropod-borne pathogens in domestic cats.

    PubMed

    André, Marcos Rogério; Filgueira, Kilder Dantas; Calchi, Ana Cláudia; Sousa, Keyla Carstens Marques de; Gonçalves, Luiz Ricardo; Medeiros, Vitor Brasil; Ximenes, Poliana Araújo; Lelis, Ivana Cristina Nunes Gadelha; Meireles, Maria Vanuza Nunes de; Machado, Rosangela Zacarias

    2017-01-01

    The role of several feline vector-borne pathogens (FVBP) as a cause of disease in cats has not been clearly determined. In fact, with the exception of Bartonella spp. and hemoplasmas, FVBP in cats has not been clearly determined in Brazil yet. The present study aimed at identifying, by using molecular methods, the presence of FVBP in three cats showing non-specific clinical signs and inclusions suggestive of hemoparasites in blood smears. Cytauxzoon felis, 'Candidatus Mycoplasma haemominutum', Ehrlichia sp. closely related to Ehrlichia canis, and Anaplasma sp. closely related to Anaplasma phagocytophilum were detected in blood samples from two out of three sampled cats. Both cats positive for multiple FVBP did not show hematological and biochemical abnormalities. The present work emphasizes the need for molecular confirmation of co-infection by multiple FVBP in cats presenting non-specific clinical signs and inclusions resembling hemoparasites in blood smears.

  7. Defining patients' knowledge and perceptions of vaginal mesh surgery.

    PubMed

    Brown, Lindsay K; Fenner, Dee E; Berger, Mitchell B; Delancey, John O L; Morgan, Daniel M; Patel, Divya A; Schimpf, Megan O

    2013-01-01

    Given recent government investigations and media coverage of the controversy regarding mesh surgery, we sought to define patients' knowledge and perceptions of vaginal mesh surgery. An anonymous survey was distributed to a convenience sample of new patients at urogynecology and female urology clinics at a single medical center during April to June 2012. The survey assessed patients' demographics, information sources, and beliefs and concerns regarding mesh surgery. The Fisher's exact test was used to identify predictors of patients' beliefs regarding mesh. Logistic and linear regressions were used to identify predictors of aversion to surgery and higher concern regarding future surgery. One hundred sixty-four women completed the survey; 62.2% (102/164) indicated knowledge of mesh surgery for prolapse and/or incontinence and were included in subsequent analyses. The mean ± SD age was 58.0 ± 12.5 years, and 24.5% reported prior mesh surgery. The most common information source was television commercials (57.8%); only 23.5% of the women reported receiving information from a medical professional. Participants indicated the following regarding vaginal mesh: class-action lawsuit in progress (55/102 [54.0%]), causes pain (47/102 [47.1%]), possibility of rejection (35/102 [34.3%]), can cause bleeding and become exposed vaginally (30/102 [29.4%]), and should be removed owing to recall (28/102 [27.5%]). Of these women, 22.1% (19/86) indicated they would not consider mesh surgery. On multivariable logistic regression, level of concern, information from friends/family, and knowledge of class-action lawsuit predicted aversion to mesh surgery. Nearly two thirds of new patients had knowledge of vaginal mesh surgery. We identified considerable misinformation and aversion to future mesh surgery among these women.

  8. Smear plus Detect-TB for a sensitive diagnosis of pulmonary tuberculosis: a cost-effectiveness analysis in an incarcerated population.

    PubMed

    Schmid, Karen Barros; Scherer, Luciene; Barcellos, Regina Bones; Kuhleis, Daniele; Prestes, Isaías Valente; Steffen, Ricardo Ewbank; Dalla Costa, Elis Regina; Rossetti, Maria Lucia Rosa

    2014-12-16

    Prison conditions can favor the spread of tuberculosis (TB). This study aimed to evaluate in a Brazilian prison: the performance and accuracy of smear, culture and Detect-TB; performance of smear plus culture and smear plus Detect-TB, according to different TB prevalence rates; and the cost-effectiveness of these procedures for pulmonary tuberculosis (PTB) diagnosis. This paper describes a cost-effectiveness study. A decision analytic model was developed to estimate the costs and cost-effectiveness of five routine diagnostic procedures for diagnosis of PTB using sputum specimens: a) Smear alone, b) Culture alone, c) Detect-TB alone, d) Smear plus culture and e) Smear plus Detect-TB. The cost-effectiveness ratio of costs were evaluated per correctly diagnosed TB case and all procedures costs were attributed based on the procedure costs adopted by the Brazilian Public Health System. A total of 294 spontaneous sputum specimens from patients suspected of having TB were analyzed. The sensibility and specificity were calculated to be 47% and 100% for smear; 93% and 100%, for culture; 74% and 95%, for Detect-TB; 96% and 100%, for smear plus culture; and 86% and 95%, for smear plus Detect-TB. The negative and positive predictive values for smear plus Detect-TB, according to different TB prevalence rates, ranged from 83 to 99% and 48 to 96%, respectively. In a cost-effectiveness analysis, smear was both less costly and less effective than the other strategies. Culture and smear plus culture were more effective but more costly than the other strategies. Smear plus Detect-TB was the most cost-effective method. The Detect-TB evinced to be sensitive and effective for the PTB diagnosis when applied with smear microscopy. Diagnostic methods should be improved to increase TB case detection. To support rational decisions about the implementation of such techniques, cost-effectiveness studies are essential, including in prisons, which are known for health care assessment problems.

  9. The sensitivity of biological finite element models to the resolution of surface geometry: a case study of crocodilian crania

    PubMed Central

    Evans, Alistair R.; McHenry, Colin R.

    2015-01-01

    The reliability of finite element analysis (FEA) in biomechanical investigations depends upon understanding the influence of model assumptions. In producing finite element models, surface mesh resolution is influenced by the resolution of input geometry, and influences the resolution of the ensuing solid mesh used for numerical analysis. Despite a large number of studies incorporating sensitivity studies of the effects of solid mesh resolution there has not yet been any investigation into the effect of surface mesh resolution upon results in a comparative context. Here we use a dataset of crocodile crania to examine the effects of surface resolution on FEA results in a comparative context. Seven high-resolution surface meshes were each down-sampled to varying degrees while keeping the resulting number of solid elements constant. These models were then subjected to bite and shake load cases using finite element analysis. The results show that incremental decreases in surface resolution can result in fluctuations in strain magnitudes, but that it is possible to obtain stable results using lower resolution surface in a comparative FEA study. As surface mesh resolution links input geometry with the resulting solid mesh, the implication of these results is that low resolution input geometry and solid meshes may provide valid results in a comparative context. PMID:26056620

  10. The incidence and clinical implication of sputum with positive acid-fast bacilli smear but negative in mycobacterial culture in a tertiary referral hospital in South Korea.

    PubMed

    Lee, Jae Seok; Kim, Eui-Chong; Joo, Sei Ick; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Shim, Young-Soo; Yim, Jae-Joon

    2008-10-01

    Although it is not rare to find sputum that is positive acid-fast bacilli (AFB) smear but subsequent culture fails to isolate mycobacteria in clinical practice, the incidence and clinical implication of those sputa from new patients has not been clearly elucidated. The aim of this study was to determine the incidence and clinical implication of sputum with positive AFB smear but negative in mycobacterial culture. All sputa that were positive AFB smear requested during diagnostic work up for new patients visiting Seoul National University Hospital from 1 January 2005 through 31 December 2006 were included. Sputa producing a positive AFB smear but negative mycobacterial culture were classified into one of four categories: laboratory failure to isolate mycobacteria, false positive AFB smear, pathogen may show a positive AFB smear other than mycobacteria, and indeterminate results. Out of 447 sputa with a positive AFB smear, 29 (6.5%) failed to culture any organism. Among these 29 sputa, 18 were caused by laboratory failure to isolate mycobacteria, six were false positive smears, and five indeterminate. Although most sputum with a positive AFB smear but negative culture could be classified as a laboratory failure, clinicians should consider the possibility of false positive AFB smear.

  11. A new procedure for dynamic adaption of three-dimensional unstructured grids

    NASA Technical Reports Server (NTRS)

    Biswas, Rupak; Strawn, Roger

    1993-01-01

    A new procedure is presented for the simultaneous coarsening and refinement of three-dimensional unstructured tetrahedral meshes. This algorithm allows for localized grid adaption that is used to capture aerodynamic flow features such as vortices and shock waves in helicopter flowfield simulations. The mesh-adaption algorithm is implemented in the C programming language and uses a data structure consisting of a series of dynamically-allocated linked lists. These lists allow the mesh connectivity to be rapidly reconstructed when individual mesh points are added and/or deleted. The algorithm allows the mesh to change in an anisotropic manner in order to efficiently resolve directional flow features. The procedure has been successfully implemented on a single processor of a Cray Y-MP computer. Two sample cases are presented involving three-dimensional transonic flow. Computed results show good agreement with conventional structured-grid solutions for the Euler equations.

  12. A Method for Field Calibration of the PA260 Phosphorus Analyzer Using Solid Adsorbent Materials

    DTIC Science & Technology

    1989-12-01

    plant environment. The solid adsorbent approach has two major advantages over other traditional air sampling devices such as bubblers or impingers...GC (60/80 mesh) or Chromosorb 106 (80/100 mesh). Both adsorbents were supplied by Alltech Associates (Deerfield, IL). The adsorbents were packed in

  13. Comparison of scanty AFB smears against culture in an area with high HIV prevalence.

    PubMed

    Lawson, L; Yassin, M A; Ramsay, A; Emenyonu, N E; Squire, S B; Cuevas, L E

    2005-08-01

    To verify among tuberculosis (TB) suspects attending hospitals in Abuja, Nigeria, if sputum smears graded as scanty are false-positive, sputum smears from 1068 patients were graded with the International Union Against Tuberculosis and Lung Disease classification. One specimen was cultured. Eight hundred and twenty-four (26%) smears were positive, 137 (4%) scanty and 2243 negative. Of 1068 cultures, 680 (64%) were positive. One hundred and thirty (95%) scanty and 809 (98%) positive smears were culture-positive. Twelve of 18 patients with a single scanty smear and 51 of 52 with > or = 2 scanty smears were culture-positive. Fewer than < 5% scanty results, < 1% of the patients treated for TB, are false-positive.

  14. [Sealing properties of three resin-based sealers].

    PubMed

    Mai, Sui; Wu, Shiyu; Gu, Lisha; Qi, Yipin; Sun, Qiurong; Ling, Junqi

    2014-11-01

    To evaluate the sealing properties of three resin- based sealers, EndoREZ, RealSEAL and RealSEAL SE. Forthy-eight extracted human anterior teeth with single root and canal were prepared using ProTaper files with crown-down technique to F3. The teeth were filled with three sealer respectively with hot gutta- percha vertical condensation technique simulating the clinical situation. Leakage quantity was detected using computerized fluid filtration meter with 10 samples in each group. The cross section morphology of apical parts of roots of 5 mm was observed with scanning electron microscope and transmission electron microscope in 3 samples of each group, respectively. The leakage quantity of EndoREZ, RealSEAL and RealSEAL SE were (2.61±0.60), (1.43±0.11) and (1.76±0.18) µl/min, respectively. The gaps between the the sealer and the canal wall were increased in in order of RealSEAL, RealSEAL SE and EndoREZ. No obvious demineralized dentin under EndoREZ and the smear layer was not completed removed. The partly demineralized dentin was observed under RealSEAL and the smear layer was totally removed. The partly demineralized dentin was seen under RealSEAL SE and the majority of smear layer was removed. Among the three resin- based sealers, RealSEAL has the best sealing properties, followed by RealSEAL SE and EndoREZ.

  15. Evaluation the virulence of Mycobacterium bovis isolated from milk samples through histopathological study in laboratory animals.

    PubMed

    Al-Saqur, I M; Al-Thwani, A N; Al-Attar, I M; Al-Mashhadani, M S

    2016-12-01

    Mycobacterium bovis has a broad host range, and it is the principal agent responsible for tuberculosis (TB) in bovine, domestic and wild mammals. M. bovis also infects human, causing zoonotic TB through ingestion, inhalation and, less frequently by contact with mucous membranes and broken skin. Zoonotic TB was formerly an endemic disease, usually transmitted to man by consumption of raw cow's milk. It is indistinguishable clinically or pathologically from TB caused by M. tuberculosis. The aims of this study were, to isolate and identified M. bovis from raw milk samples by different methods, and evaluate the virulence of M. bovis in laboratory animals (Rabbit). To conduct the study, ninety three cow's milk samples were collected from farms around Baghdad governorate. The decontamination of milk samples was firstly carried out, then samples were subjected to routine tests which include, direct smear for Ziehl Neelsen acid fast stain, culture, each sample was cultured on Lowenstein Jensen media with Sodium pyruvite (All cultures incubated on 37°C for 4-10weeks with continuous observation), and biochemical testes as Nitrate reduction test, Niacin paper strip test and pyrazinamidase test, were employed to diagnose and identified the bacteria. Beside molecular assay was used to confirm the identification of the isolates by Polymerase Chain Reaction (PCR) using specific primers for M. bovis. The virulence of these isolates were investigated through inoculate it in group of laboratory animals consist of 8 rabbit in addition to other group of 4 animals as control (inoculate with Phosphate Buffer Saline). The animals were scarified after 6weeks of inoculation, post- mortem examination was carried out, smears were taken from lesions, and tissue samples were collected from lymph nodes and different organs. The results revealed five isolates of M. bovis in direct smear by acid fast Ziehl-Neelsen stain, while eight isolates observed by culture, the colonies appeared with characteristic feature of cream color, rough, and with irregular edge. The molecular assay using PCR technique confirmed the diagnosis of eight positive isolates in smears and culture. The virulence of these isolates were investigated through the pathological effects appeared in inoculated rabbit which showed lesions scattered mainly in lymph nodes and different organs as lung, liver, spleen and kidney when compared with control group which were naive. Beside the infiltration of mononuclear cells in the internal organs particularly in the lungs. The result of histopathological examination clarified the virulence of M. bovis isolates, and its impact on tissue and organs of the rabbit. Our study conclude the presence of M. bovis isolates in milk in high percentage pause important source of tuberculosis infection for human being. Copyright © 2016.

  16. Added value of molecular assay Xpert MTB/RIF compared to sputum smear microscopy to assess the risk of tuberculosis transmission in a low-prevalence country.

    PubMed

    Opota, O; Senn, L; Prod'hom, G; Mazza-Stalder, J; Tissot, F; Greub, G; Jaton, K

    2016-07-01

    Airborne precautions are required at hospital admission for patients with suspected pulmonary tuberculosis. The isolation is maintained until 3 serially collected sputum smears are acid-fast bacilli negative, a time- and labor-intensive method with limited sensitivity and specificity, which has a great impact on patient flow management. We evaluated the possibility of replacing the result of microscopy by the semiquantitative result of the molecular point-of-care test Xpert MTB/RIF to assess patients' transmission risk to quickly guide airborne isolation decisions in low-endemic countries. The performance of the Xpert MTB/RIF, used as a first-line test, was compared to the results of microscopy for specimens (n=242) collected from May 2010 to December 2014 in Lausanne, Switzerland. The sensitivity and specificity of Xpert MTB/RIF were 91.5% (65/71) and 99.6% (170/171), respectively, vs. 64.8% (46/71) and 94.2% (161/171) for microscopy. Samples with negative Xpert MTB/RIF were all smear negative for Mycobacterium tuberculosis (negative predictive value, 100%). The semiquantitative results of Xpert MTB/RIF-high, medium, low or very low-were found to correlate with acid-fast bacilli detection: positive predictive value of 100% (6/6), 96.5% (27/28), 52.2% (12/23) and 11.1% (1/9) respectively. Finally, when including clinical criteria, we identified 11 smear-negative but Xpert MTB/RIF-positive patients with a significant transmission potential. In conclusion, our data support the introduction of an Xpert MTB/RIF-based strategy as a replacement of smear microscopy for a faster and more accurate management of tuberculosis patients' transmission risk in a low-prevalence country. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Urothelial cells in smears from cervix uteri

    PubMed Central

    Palaoro, Luis Alberto; Guerra, Fernando; Angeleri, Anabela; Palamas, Marta; Melba, Sardi-Segovia; Rocher, Adriana Esther

    2012-01-01

    Objectives: To establish the cytological criteria to identify the urothelial cells in cervical smears in order to avoid mistakes in the cytological diagnosis. Materials and Methods: Cervical smears from 34 post menopausal women with vesicovaginal fistulas, advanced bladder prolapse and genital erosive lichen planes (vulvar kraurosis) (Group 1) and transitional cell metaplasia of the cervix (TCM, Group 2) were stained with Papanicolaou technique. The cervical samples were taken during the routine annual examination for prevention of the uterine cancer. Results: The smears of cervix from Group 1 showed urothelial cells from the three layers of the transitional epithelium. The umbrella cells are the bigger ones with relatively large nuclei. Frequently, they are multinucleated with single or multiple nucleoli and a typical “frothy” cytoplasm (cytoplasmic vacuoles). The cells of the Group 2 showed nuclei with oval to spindled shapes, some tapered ends, less cytoplasm than squamous metaplastic cells, powdery chromatin, small nucleoli and nuclear grooves. Conclusions: The umbrella cells may be mistaken for dysplastic cells originating in low grade squamous intraepithelial lesions lesions (LSILs) due to their nuclear and cytoplasm sizes. Therefore, it is important to know the possibility of their appearance in the cervical smears, especially in post menopausal patients in order to avoid a false diagnosis of an intraepithelial lesion. It is unlikely that deeper cells of urothelium would be confused with high grade squamous intraepithelial lesion (HSIL) cells. However, their presence might be a reason of mistake in the diagnosis. TCM is an under-recognized metaplastic phenomenon of the cervix and vagina, which is a mimicker of high-grade squamous intraepithelial lesion. The differential characteristic between umbrella cells, cells from TCM and the deeper urothelial cells, and LSIL and HSIL are detailed in the present paper. PMID:22438615

  18. Age Specific Cytological Abnormalities in Women Screened for Cervical Cancer in the Emirate of Abu Dhabi.

    PubMed

    Al Zaabi, Muna; Al Muqbali, Shaikha; Al Sayadi, Thekra; Al Ameeri, Suhaila; Coetsee, Karin; Balayah, Zuhur; Ortashi, Osman

    2015-01-01

    Cervical cancer is the second most common cancer in women worldwide, with about 500,000 new cases and 270,000 deaths each year. Globally, it is estimated that over one million women currently have cervical cancer, most of whom have not been diagnosed, or have no access to treatment that could cure them or prolong their lives. In the United Arab Emirates (UAE) cervical cancer is the third most common cancer in women. A population-based cross-sectional retrospective survey of cervical smear abnormalities was conducted in the Emirate of Abu Dhabi, UAE, from January 2013 to December 2013 by collecting consecutive liquid-based cytology samples from the Department of Pathology at the SKMC Hospital in Abu Dhabi city. The total number of women screened for cervical cancer for the year 2013 at SKMC was 4,593, with 225 (4.89%) abnormal smears. The majority of the abnormal smear results were atypical squamous cells of undetermined significance (ASCUS) 114 (2.48%). This study showed 60% increase in the rate of abnormal cervical smears in the UAE over the last 10 years. In this study the highest incidence of high grade abnormalities were seen in women above the age of 61 years (1.73%), this might be due to the fact that this group of women missed the chance of screening of cervical cancer earlier in their lives or could be explained by the well-known second peak of HPV infection seen in many prevalence studies. We conclude that the rate of abnormal cervical smear in the screened Abu Dhabi women is not different from the rate in developed countries. A notable increase in both low and high grade abnormalities has occurred within the last decade.

  19. Role of PCR method using IS6110 primer in detecting Mycobacterium tuberculosis among the clinically diagnosed childhood tuberculosis patients at an urban hospital in Dhaka, Bangladesh.

    PubMed

    Kabir, Senjuti; Uddin, Mohammad Khaja Mafij; Chisti, Mohammod Jobayer; Fannana, Tilka; Haque, Mohammad Enamul; Uddin, Muhammad Reaj; Banu, Sayera; Ahmed, Tahmeed

    2018-03-01

    Better methods are needed for the accurate detection of child tuberculosis (TB). This study compared different laboratory tests and evaluated IS6110 PCR for the detection of Mycobacterium tuberculosis (MTB) among clinically diagnosed child TB patients. A total of 102 paediatric patients (<15 years old) with clinically diagnosed TB were enrolled in this study. The patients were admitted to the icddr,b hospital in Dhaka between 2003 and 2005. Sputum/gastric lavage samples were collected for smear microscopy, culture (solid/Lowenstein-Jensen medium and liquid/MGIT), and IS6110 PCR testing. The sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of smear microscopy and PCR were compared to the two culture methods. Three patients were positive on smear microscopy (2.9%). MTB was detected by conventional culture in 15.7% (16/102), liquid culture in 14% (14/100), and IS6110 PCR in 61.8% (63/102). PCR detected an additional 45 patients who were undetected with the three other tests. Compared to conventional and liquid culture, respectively, smear microscopy showed sensitivity of 18.8% and 21.4%, specificity of 100% individually, PPV of 100% individually, and NPV of 86.9% and 88.7%, whereas PCR had sensitivity of 87.5% and 92.9%, specificity of 43% individually, PPV of 22.2% and 21%, and NPV of 94.9% and 97.4%. PCR can be useful compared to smear microscopy and culture methods and is applicable as a rapid screening test for child TB. A larger scale study is required to determine its diagnostic efficacy in improving the detection of child TB in the presence and absence of severe malnutrition. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Topography and presence of a smear layer in deciduous molars prepared with high-speed cutting and ultrasonic abrasion: an in-vitro study.

    PubMed

    Vieira, Áurea Simone Barroso; Pedro, Rafael de Lima; Antunes, Leonardo Dos Santos; Alves Dos Santos, Márcia Pereira; Antunes, Livia Azeredo Alves; Primo, Laura Guimarães; Maia, Lucianne Cople

    2011-05-01

    The aim of this in-vitro study was to compare the effect of high-speed cutting (HS) with ultrasonic abrasion (US) concerning the internal topography and the presence of a smear layer in a cavity preparation performed in healthy deciduous molars. Seven first deciduous molars were used. Two occlusal cavity preparation were done, one in the medial fossula and another in the distal fossula, which were chosen randomly. One preparation was carried out with a diamond point adapted to the HS system (GI), while a chemical vapor deposition (CVD) point adapted to a US device (GII) was used for the other preparation. Subsequently, all samples (n = 14) were cleaved to observe the inside and then prepared for evaluation using scanning electron photomicroscopy. The internal topography of the prepared cavities was descriptively analyzed. In order to assess the presence of a smear layer, scores were tabulated using the 2000 GMC program and analyzed using the Mann-Whitney test. Concerning the internal topography, the presence of striae was verified in both groups. In the GI group they were finer, found in a greater number, and with narrower spaces between them. In the GII group, the striae were undulating, similar to the effect of wheels on sand, and with wider spaces between them. As regards the presence of a smear layer, there was no statistically significant difference between the groups (P > 0.05). In view of the methodology employed, it may be concluded that cavity preparation with a CVD point in a US abrasion system led to the formation of fewer striae and both devices promoted the marked presence of a smear layer, obstructing dentinal tubuli.

  1. Enhanced retained dose uniformity in NiTi spinal correction rod treated by three-dimensional mesh-assisted nitrogen plasma immersion ion implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Q. Y.; Hu, T.; Kwok, Dixon T. K.

    2010-05-15

    Owing to the nonconformal plasma sheath in plasma immersion ion implantation of a rod sample, the retained dose can vary significantly. The authors propose to improve the implant uniformity by introducing a metal mesh. The depth profiles obtained with and without the mesh are compared and the implantation temperature at various locations is evaluated indirectly by differential scanning calorimeter. Our results reveal that by using the metal mesh, the retained dose uniformity along the length is greatly improved and the effects of the implantation temperature on the localized mechanical properties of the implanted NiTi shape memory alloy rod are nearlymore » negligible.« less

  2. Facial expression reconstruction on the basis of selected vertices of triangle mesh

    NASA Astrophysics Data System (ADS)

    Peszor, Damian; Wojciechowska, Marzena

    2016-06-01

    Facial expression reconstruction is an important issue in the field of computer graphics. While it is relatively easy to create an animation based on meshes constructed through video recordings, this kind of high-quality data is often not transferred to another model because of lack of intermediary, anthropometry-based way to do so. However, if a high-quality mesh is sampled with sufficient density, it is possible to use obtained feature points to encode the shape of surrounding vertices in a way that can be easily transferred to another mesh with corresponding feature points. In this paper we present a method used for obtaining information for the purpose of reconstructing changes in facial surface on the basis of selected feature points.

  3. Transversely Excited Atmospheric CO2 Laser-Induced Plasma Spectroscopy for the Detection of Heavy Metals in Soil

    NASA Astrophysics Data System (ADS)

    Khumaeni, A.; Sugito, H.; Setia Budi, W.; Yoyo Wardaya, A.

    2018-01-01

    A rapid detection of heavy metals in soil was presented by the metal-assisted gas plasma method using specific characteristics of a pulsed, transversely excited atmospheric (TEA) CO2 laser. The soil particles were placed in a hole made of acrylic plate. The sample was covered by a to prevent the soil particles from being blown off. The mesh also functioned to initiate a luminous plasma. When a TEA CO2 laser (1500 mJ, 200 ns) was focused on the soil sample, passing through the metal mesh, some of the laser energy was used to generate the gas plasma on the mesh surface, and the remaining laser energy was employed to ablate the soil particles. The fine, ablated soil particles moved into the gas plasma region to be dissociated and excited. Using this technique, analysis can be made with reduced sample pretreatment, and therefore a rapid analysis can be performed efficiently. The results proved that the signal to noise ratio (S/N) of the emission spectral lines is much better for the case of the present method (mesh method) compared to the case of standard laser-induced breakdown spectroscopy using the pellet method. Rapid detection of heavy metal elements in soil has been successfully carried out. The detection limits of Cu and Hg in soil were estimated to be 3 and 10 mg/kg, respectively. The present method has good potential for rapid and sensitive detection of heavy metals in soil samples.

  4. Rapid multiple immunofluorescent staining for the simultaneous detection of cytokeratin and vimentin in the cytology of canine tumors.

    PubMed

    Sawa, Mariko; Yabuki, Akira; Kohyama, Moeko; Miyoshi, Noriaki; Yamato, Osamu

    2018-06-01

    Immunocytochemistry (ICC) is utilized as an advanced technique in veterinary cytology. In tumor diagnosis, cytokeratin and vimentin are markers used to distinguish the origin of tumor cells. Standard enzyme-based ICC has limitations in clinical use; and therefore, more convenient and reliable methods are needed. The purpose of this study was to develop a rapid multiple immunofluorescent (RMIF) detection method for dual cytokeratin and vimentin staining on cytology slides in dogs. Air-dried smear samples from solid tumors and sediments of pleural effusions were prepared from dogs (n = 14) that were admitted to the Veterinary Teaching Hospital, Kagoshima University, Japan. Mouse monoclonal anti-human cytokeratin (AE1/AE3) and rabbit monoclonal anti-human vimentin (SP20) antibodies were used as primary antibodies, followed by staining with Alexa Fluor-conjugated secondary antibodies. Staining using the RMIF method was compared with enzyme-based ICC staining. Rapid multiple immunofluorescent immunostaining was clear and specific in the evaluated smears, whereas the enzyme-based ICC showed nonspecific signals. By using the RMIF staining method, epithelial cells, mesenchymal cells, and mesothelial cells could be classified on a single smear of a pleural effusion. In smears of lymph nodes with epithelial tumor metastases, the RMIF method successfully detected metastatic epithelial tumor cells. The RMIF method might be a useful tool for diagnostic cytology in veterinary medicine. © 2018 American Society for Veterinary Clinical Pathology.

  5. Biaxial analysis of synthetic scaffolds for hernia repair demonstrates variability in mechanical anisotropy, non-linearity and hysteresis.

    PubMed

    Deeken, Corey R; Thompson, Dominic M; Castile, Ryan M; Lake, Spencer P

    2014-10-01

    Over the past 60 years, the soft tissue repair market has grown to include over 50 types of hernia repair materials. Surgeons typically implant these materials in the orientation that provides maximum overlap of the mesh over the defect, with little regard for mechanical properties of the mesh material. If the characteristics of the meshes were better understood, an appropriate material could be identified for each patient, and meshes could be placed to optimize integration with neighboring tissue and avoid the mechanical mis-match that can lead to impaired graft fixation. The purpose of this study was to fully characterize and compare the mechanical properties of thirteen types of hernia repair materials via planar biaxial tensile testing. Equibiaxial (i.e., equal simultaneous loading in both directions) and strip biaxial (i.e., loading in one direction with the other direction held fixed) tests were utilized as physiologically relevant loading regimes. After applying a 0.1N pre-load on each arm, samples were subjected to equibiaxial cyclic loading using a triangular waveform to 2.5mm displacement on each arm at 0.1Hz for 10 cycles. Samples were then subjected to two strip biaxial tests (using the same cyclic loading protocol), where extension was applied along a single axis with the other axis held fixed. The thirteen evaluated mesh types exhibited a wide range of mechanical properties. Some were nearly isotropic (C-QUR™, DUALMESH(®), PHYSIOMESH™, and PROCEED(®)), while others were highly anisotropic (Ventralight™ ST, Bard™ Mesh, and Bard™ Soft Mesh). Some displayed nearly linear behavior (Bard™ Mesh), while others were non-linear with a long toe region followed by a sharp rise in tension (INFINIT(®)). These materials are currently utilized in clinical settings as if they are uniform and interchangeable, and clearly this is not the case. The mechanical properties most advantageous for successful hernia repairs are currently only vaguely described in the clinical literature. The characteristics of the human abdominal wall must be extensively characterized to provide a thorough understanding of the tissue being reinforced/replaced by these meshes. A better understanding of these mechanical differences would enable matching of patient characteristics to a specific mesh with the properties best suited to that particular repair. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall.

    PubMed

    Ortillés, Á; Pascual, G; Peña, E; Rodríguez, M; Pérez-Köhler, B; Mesa-Ciller, C; Calvo, B; Bellón, J M

    2017-11-01

    The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex vivo and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Fog water collection effectiveness: Mesh intercomparisons

    USGS Publications Warehouse

    Fernandez, Daniel; Torregrosa, Alicia; Weiss-Penzias, Peter; Zhang, Bong June; Sorensen, Deckard; Cohen, Robert; McKinley, Gareth; Kleingartner, Justin; Oliphant, Andrew; Bowman, Matthew

    2018-01-01

    To explore fog water harvesting potential in California, we conducted long-term measurements involving three types of mesh using standard fog collectors (SFC). Volumetric fog water measurements from SFCs and wind data were collected and recorded in 15-minute intervals over three summertime fog seasons (2014–2016) at four California sites. SFCs were deployed with: standard 1.00 m2 double-layer 35% shade coefficient Raschel; stainless steel mesh coated with the MIT-14 hydrophobic formulation; and FogHa-Tin, a German manufactured, 3-dimensional spacer fabric deployed in two orientations. Analysis of 3419 volumetric samples from all sites showed strong relationships between mesh efficiency and wind speed. Raschel mesh collected 160% more fog water than FogHa-Tin at wind speeds less than 1 m s–1 and 45% less for wind speeds greater than 5 m s–1. MIT-14 coated stainless-steel mesh collected more fog water than Raschel mesh at all wind speeds. At low wind speeds of < 1 m s–1 the coated stainless steel mesh collected 3% more and at wind speeds of 4–5 m s–1, it collected 41% more. FogHa-Tin collected 5% more fog water when the warp of the weave was oriented vertically, per manufacturer specification, than when the warp of the weave was oriented horizontally. Time series measurements of three distinct mesh across similar wind regimes revealed inconsistent lags in fog water collection and inconsistent performance. Since such differences occurred under similar wind-speed regimes, we conclude that other factors play important roles in mesh performance, including in-situ fog event and aerosol dynamics that affect droplet-size spectra and droplet-to-mesh surface interactions.

  8. Lack of size selectivity for paddlefish captured in hobbled gillnets

    USGS Publications Warehouse

    Scholten, G.D.; Bettoli, P.W.

    2007-01-01

    A commercial fishery for paddlefish Polyodon spathula caviar exists in Kentucky Lake, a reservoir on the lower Tennessee River. A 152-mm (bar-measure) minimum mesh size restriction on entanglement gear was enacted in 2002 and the minimum size limit was increased to 864 mm eye-fork length to reduce the possibility of recruitment overfishing. Paddlefish were sampled in 2003-2004 using experimental monofilament gillnets with panels of 89, 102, 127, 152, 178, and 203-mm meshes and the efficacy of the mesh size restriction was evaluated. Following the standards of commercial gear used in that fishery, nets were "hobbled" (i.e., 128 m ?? 3.6 m nets were tied down to 2.4 m; 91 m ?? 9.1 m nets were tied down to 7.6 m). The mean lengths of paddlefish (Ntotal = 576 fish) captured in each mesh were similar among most meshes and bycatch rates of sublegal fish did not vary with mesh size. Selectivity curves could not be modeled because the mean and modal lengths of fish captured in each mesh did not increase with mesh size. Ratios of fish girth to mesh perimeter (G:P) for individual fish were often less than 1.0 as a result of the largest meshes capturing small paddlefish. It is unclear whether lack of size selectivity for paddlefish was because the gillnets were hobbled, the unique morphology of paddlefish, or the fact that they swim with their mouths agape when filter feeding. The lack of size selectivity by hobbled gillnets fished in Kentucky Lake means that managers cannot influence the size of paddlefish captured by commercial gillnet gear by changing minimum mesh size regulations. ?? 2006 Elsevier B.V. All rights reserved.

  9. Gastric carcinoma metastatic to the bone marrow: immunoperoxidase identification of KMO-1 antigen in MGG-destained aspirate.

    PubMed

    Kobayashi, T K; Yakushiji, M

    1991-01-01

    A case is presented that illustrates the application of the immunoperoxidase technique to the May-Grünwald-Giemsa (MGG)-destained bone marrow aspirate. The cytologic findings in a MGG-stained smear of the bone marrow suggested a metastatic epithelial tumor. Subsequently, a positive reaction to KMO-1, a monoclonal antibody raised against a colon carcinoma cell line, was demonstrated in tumor cells in the MGG-destained smear sample as well as in the paraffin-embedded section of the primary gastric cancer. The demonstration of the cancer-associated antigen in the MGG-destained material may be useful in establishing the diagnosis of metastatic tumor in the bone marrow.

  10. Effects of modifying the World Health Organization standard operating procedures for malaria microscopy to improve surveillance in resource poor settings.

    PubMed

    Fernando, Sumadhya D; Ihalamulla, Ratnasiri L; Wickremasinghe, Renu; de Silva, Nipun L; Thilakarathne, Janani H; Wijeyaratne, Pandu; Premaratne, Risintha G

    2014-03-15

    Individuals with fever are screened for malaria in specially-established malaria diagnostic laboratories set up in rural hospitals in the Northern and Eastern Provinces of Sri Lanka. Large numbers of blood smears negative for malaria parasites are being screened daily. Good quality smears are essential to maintain a high diagnostic competency among the technical staff. The modifications made to the World Health Organization (WHO) standard operating procedures to improve the quality of smears have been studied. A blinded, controlled, interventional study was conducted in 22 intervention and 21 control malaria diagnostic laboratories. Changes were made to the WHO standard operating procedure protocols to prepare, stain and examine blood smears for malaria parasite detection which were implemented in intervention laboratories. These included wipe-cleaning slides, preparing both thick and thin smears on the same slide, reversing the order of collecting blood for thick and thin smears, dry fixing thick smear for 20-25 minutes under table lamp, polishing the edge of spreader slide with sand paper and fixing the thin smear with methanol if not stained within four hours. Parameters with respect to quality of the smear as per WHO criteria were studied using randomly selected slides, and time taken for the report to be issued was recorded in both groups before and after the intervention. There were no significant differences observed in the parameters studied at baseline between the two groups or pre and post intervention in the control group. In the intervention group streak formation in thin smears was reduced from 29.4% to 5.0%. The average fixing time of thick smears was reduced from 2.4 hours to 20 minutes. Inappropriate thickness of thick smears reduced from 18.3% to 1.5%. Overall quality of thick smears and thin smears increased from 76.1% to 98.0% and 81.7% to 87.0%, respectively. The quality of slides bearing both thick and thin smears increased from 60.0% to 87.0%. New protocols with amendments to the WHO standard technical procedures ensure that good quality blood smears are prepared rapidly to diagnose malaria and the time required to issue the reports was reduced.

  11. Quality of diagnosis and monitoring of tuberculosis in Northern Ethiopia: medical records-based retrospective study.

    PubMed

    Mala, George; Spigt, Mark G; Gidding, Luc G; Blanco, Roman; Dinant, Geert-Jan

    2015-10-01

    To determine quality of diagnosis and monitoring of treatment response of patients with smear-negative pulmonary tuberculosis (TB) compared with smear-positive cases in Ethiopia. A retrospective analysis of medical records of newly diagnosed pulmonary TB cases that were registered for taking anti-TB medication and had completed treatment between 2010 and 2012. We evaluated the percentage of cases that were managed according to the International Standards of Tuberculosis Care (ISTC) and compared smear-negative with smear-positive cases. We analysed 1168 cases of which 742 (64%) were sputum smear-negative cases. Chest radiography examination at diagnosis and microbiological testing at the end of the intensive phase of treatment was performed in a smaller proportion than in smear-positive TB cases (70% vs. 79%, P value <0.001) and (70% vs. 95%, P value <0.001), respectively. Clinical actions recommended in the ISTC are of greatest importance in minimising pitfalls in care of smear-negative TB yet were performed less often in smear-negative than smear-positive TB cases. © The Author(s) 2015.

  12. [Efficacy of a rapid test to diagnose Plasmodium vivax in symptomatic patients of Chiapas, Mexico].

    PubMed

    González-Cerón, Lilia; Rodríguez, Mario H; Betanzos, Angel F; Abadía, Acatl

    2005-01-01

    To evaluate, under laboratory conditions, the sensitivity and specificity of a rapid diagnostic test (OptiMAL), based on immunoreactive strips, to detect Plasmodium vivax infection in febrile patients in Southern Chiapas, Mexico. The presence of parasites in blood samples of 893 patients was investigated by Giemsa-stained thick blood smear microscopic examination (gold standard). A blood drop from the same sample was smeared on immunoreactive strips to investigate the presence of the parasite pLDH. Discordant results were resolved by PCR amplification of the parasite's 18S SSU rRNA, to discard infection. OptiMAL had an overall sensitivity of 93.3% and its specificity was 99.5%. Its positive and negative predictive values were 96.5% and 98.9%, respectively. Signal intensity in OptiMAL strips correlated well with the parasitemia density in the blood samples (r = 0.601, p = 0.0001). This rapid test had acceptable sensitivity and specificity to detect P. vivax under laboratory conditions and could be useful for malaria diagnosis in field operations in Mexico.

  13. Frequency and Clinical Epidemiology of Canine Monocytic Ehrlichiosis in Dogs Infested with Ticks from Sinaloa, Mexico

    PubMed Central

    Sosa-Gutierrez, Carolina Guadalupe; Quintero Martinez, Maria Teresa; Gaxiola Camacho, Soila Maribel; Esteve-Gassent, Maria D.; Gordillo-Pérez, María-Guadalupe

    2013-01-01

    Ehrlichia canis is a rickettsial intracellular obligate bacterial pathogen and agent of canine monocytic ehrlichiosis. The prevalence of this disease in veterinary medicine can vary depending on the diagnostic method used and the geographic location. One hundred and fifty-two canine blood samples from six veterinary clinics and two shelters from Sinaloa State (Mexico) were analyzed in this study. All animals were suspected of having Canine Monocytic Ehrlichiosis (CME). The diagnostic methods used were the ELISA (Snap4Dx, IDEXX) together with blood smear and platelet count. From all dogs blood samples analyzed, 74.3% were positive to E. canis by ELISA and 40.1% were positive by blood smear. The sensitivity and specificity observed in the ELISA test were 78.8% and 86.7%. In addition, thrombocytopenia was presented in 87.6% of positive dogs. The predominant clinical manifestations observed were fever, anorexia, depression, lethargy, and petechiae. Consequently, this is the first report in which the morulae were visualized in the blood samples, and E. canis-specific antibodies were detected in dogs from Sinaloa, Northwest of Mexico. PMID:26464910

  14. The Effect of Smear Layer Removal on Endodontic Outcomes

    DTIC Science & Technology

    2012-06-01

    Sundqvist G. The antibacterial effect of sodium hypochlorite and EDTA in 60 cases of endodontic therapy. Int Endod J 1985;18:35-40. 11. Conner DA, Caplan...outcomes. KEY WORDS: Smear layer, smear layer removal, smear layer creation, EDTA, Sodium hypochlorite , Periapical index INTRODUCTION: The...identified the most efficient process for removal of the smear layer. Normal saline and sodium hypochlorite (NaOCl) have been shown not to remove

  15. Role of 2-month sputum smears in predicting culture conversion in pulmonary tuberculosis.

    PubMed

    Su, W-J; Feng, J-Y; Chiu, Y-C; Huang, S-F; Lee, Y-C

    2011-02-01

    Sputum smears and culture conversion are frequently used to evaluate treatment response in pulmonary tuberculosis patients. Limited data are available on the evaluation of the correlation between under-treatment sputum smear results and culture conversion. This prospective study included sputum culture-proven pulmonary tuberculosis patients at six hospitals in Taiwan. At least two sets of sputum were collected at the completion of 8 weeks of TB treatment. The sensitivities and specificities of 2-month sputum smears were estimated based on culture conversion status. A total of 371 patients were enrolled for analysis. Factors associated with culture conversion included having a smear positive before treatment, presence of a cavity on radiography, rifampicin resistance and usage of the DOTS (directly observed therapy, short course) strategy. The sensitivities of 2-month sputum smears for culture conversion among all patients, initially smear-positive patients and initially smear-negative patients were 64.3, 71.4 and 38%, respectively, and the specificities were 81.6, 69.9 and 92.8%, respectively. In patients who were 2-month sputum smear-positive, the 2-month culture conversion rate was 80% if the patients were under DOTS and without cavitary lesions in radiograms. The predictive value of 2-month sputum smears in culture conversion was limited and highly influenced by clinical factors in pulmonary tuberculosis patients.

  16. Knowledge of cervical cancer, attitude and husband’s support of Pap smear among multiparous women which have Pap’s smear examination in Aviati clinic Padang Bulan Medan

    NASA Astrophysics Data System (ADS)

    Feriyawati, L.; Anggraini, D. R.; Fitrie, A. A.; Anggreini, R. N.

    2018-03-01

    Cervical cancer is a serious health problem and stated as the second cause of death of woman worldwide. Several studies have noted a higher incidence of cervical cancer with increasing parity. Early detection with Pap smear is proven to reduce mortality of patients. Knowledge, attitude and husband’s support contributed to theled womanto follow Pap smear examination. This study explores the knowledge of cervical cancer, attitude and husband’ s support of Pap smearin multiparous women that have Pap smear examination. This research is a quantitative study with cross sectional approach recruited 50 respondents as multiparous women that have Pap smear examination inAviati Clinic, Padang Bulan, Medan. The data were collected by self-reports using structured objectives by questionnaires. The result of this study showed that 66% respondents have high knowledge of cervical cancer and 76% respondents have ahigh attitude of Pap smear, but they almost have low husband’s support of Pap smear including information support (62%), emotional support (46%) and real support (50%). This study has revealed that multiparous women that had Pap smear examination generally had high knowledge about cervical cancer and positive attitude about Pap smear, even most of them had low husband’s support.

  17. Simulation of a Single-Element Lean-Direct Injection Combustor Using a Polyhedral Mesh Derived from Hanging-Node Elements

    NASA Technical Reports Server (NTRS)

    Wey, Thomas; Liu, Nan-Suey

    2013-01-01

    This paper summarizes the procedures of generating a polyhedral mesh derived from hanging-node elements as well as presents sample results from its application to the numerical solution of a single element lean direct injection (LDI) combustor using an open-source version of the National Combustion Code (NCC).

  18. Effectiveness of a computer-based tutorial for teaching how to make a blood smear.

    PubMed

    Preast, Vanessa; Danielson, Jared; Bender, Holly; Bousson, Maury

    2007-09-01

    Computer-aided instruction (CAI) was developed to teach veterinary students how to make blood smears. This instruction was intended to replace the traditional instructional method in order to promote efficient use of faculty resources while maintaining learning outcomes and student satisfaction. The purpose of this study was to evaluate the effect of a computer-aided blood smear tutorial on 1) instructor's teaching time, 2) students' ability to make blood smears, and 3) students' ability to recognize smear quality. Three laboratory sessions for senior veterinary students were taught using traditional methods (control group) and 4 sessions were taught using the CAI tutorial (experimental group). Students in the control group received a short demonstration and lecture by the instructor at the beginning of the laboratory and then practiced making blood smears. Students in the experimental group received their instruction through the self-paced, multimedia tutorial on a laptop computer and then practiced making blood smears. Data was collected from observation, interview, survey questionnaires, and smear evaluation by students and experts using a scoring rubric. Students using the CAI made better smears and were better able to recognize smear quality. The average time the instructor spent in the room was not significantly different between groups, but the quality of the instructor time was improved with the experimental instruction. The tutorial implementation effectively provided students and instructors with a teaching and learning experience superior to the traditional method of instruction. Using CAI is a viable method of teaching students to make blood smears.

  19. Hepatozoon caimani in Caiman crocodilus yacare (Crocodylia, Alligatoridae) from North Pantanal, Brazil.

    PubMed

    Bouer, Andréa; André, Marcos Rogério; Gonçalves, Luiz Ricardo; Luzzi, Mayara de Cássia; Oliveira, Juliana Paula de; Rodrigues, Adriana Carlos; Varani, Alessandro de Melo; Miranda, Vitor Fernandes Oliveira de; Perles, Lívia; Werther, Karin; Machado, Rosangela Zacarias

    2017-01-01

    Hepatozoon species are the most common intracellular hemoparasite found in reptiles. Hepatozoon caimani, whose vectors are Culex mosquitoes, has been detected in a high prevalence among caimans in Brazil by blood smears examinations. The present work aimed to detect and characterize the Hepatozoon spp. found in 33 caimans (24 free-ranging and 9 captive; 28 males and 5 females) (Caiman crocodilus yacare) sampled at Poconé, North Pantanal, state of Mato Grosso, Brazil, using blood smears examinations and molecular techniques. Hepatozoon spp.-gametocytes were found in 70.8% (17/24) and 88.8% (8/9) of blood smears from free-ranging and captive caimans, respectively. Hepatozoon spp. 18S rRNA DNA was found in 79.2% (19/24) and 88.8% (8/9) of free-ranging and captive caimans, respectively. Comparative analysis of parasitized and non-parasitized erythrocytes showed that all analyzed features were significantly different (P<0.05) for both linear and area dimensions. Phylogenetic analysis based on 18S rRNA sequences grouped the Hepatozoon spp. sequences detected in the present study together with H. caimani, recently detected in caimans in southern Pantanal.

  20. Effect of ND:YAG laser irradiation and root planing on the root surface: structural and thermal effects.

    PubMed

    Wilder-Smith, P; Arrastia, A M; Schell, M J; Liaw, L H; Grill, G; Berns, M W

    1995-12-01

    Effects of ND:YAG laser irradiation on untreated and root planed tooth roots were investigated to determine whether a cleaning effect and/or removal of smear layer could be achieved without concomitant microstructural or thermal damage. Sixty (60) healthy extracted teeth were either untreated, irradiated only, root planed only, or irradiated and root planed. Intra-pulpal and surface temperatures were monitored during irradiation, then SEM was performed. Smear layer elimination was achieved without inducing hard tissue microstructural damage at 5W, using pulse durations and intervals of 0.1 s, a fluence of 0.77 J/cm2, and a total energy density of approximately 700 J/cm2. However, these results were not consistent in all samples. At these parameters, intra-pulpal temperature increases of 9 to 22 degrees C and surface temperature increases of 18 to 36 degrees C were recorded. Thus, despite their effectiveness for smear layer removal, these parameters may not be appropriate for clinical use as an adjunct to conventional periodontal therapy.

  1. Screening for cervical cancer using automated analysis of PAP-smears.

    PubMed

    Bengtsson, Ewert; Malm, Patrik

    2014-01-01

    Cervical cancer is one of the most deadly and common forms of cancer among women if no action is taken to prevent it, yet it is preventable through a simple screening test, the so-called PAP-smear. This is the most effective cancer prevention measure developed so far. But the visual examination of the smears is time consuming and expensive and there have been numerous attempts at automating the analysis ever since the test was introduced more than 60 years ago. The first commercial systems for automated analysis of the cell samples appeared around the turn of the millennium but they have had limited impact on the screening costs. In this paper we examine the key issues that need to be addressed when an automated analysis system is developed and discuss how these challenges have been met over the years. The lessons learned may be useful in the efforts to create a cost-effective screening system that could make affordable screening for cervical cancer available for all women globally, thus preventing most of the quarter million annual unnecessary deaths still caused by this disease.

  2. Increased uptake of cervical screening by women with HIV infection in Auckland regardless of ethnicity, requirement for an interpreter or level of education.

    PubMed

    Lowe, Michele; Handy, Rupert; Ingram, Joan; Nisbet, Mitzi; Ritchie, Stephen; Thomas, Mark; Briggs, Simon

    2016-07-15

    Current guidelines recommend that women with HIV infection receive annual cervical smears. We evaluated the uptake of annual cervical smears by women with HIV infection under the care of the Infectious Disease Service at Auckland City Hospital. In an attempt to identify potential barriers to regularly receiving an annual cervical smear, we invited the women to complete a questionnaire. The responses from women who had regularly received an annual cervical smear were compared with those who had not. The proportion of women who had received a cervical smear increased from 44% in 2001, to 73% in 2010 (p=0.001). Ninety-three women (76%) completed the study questionnaire. No statistically significant differences were found in the questionnaire responses between the women who had regularly received an annual cervical smear and those who had not. The proportion of women in this cohort who received a cervical smear in 2010 is comparable with other studies of women with HIV infection in New Zealand and overseas. We have not been able to identify barriers that prevent women with HIV infection in Auckland regularly receiving an annual cervical smear. We plan to encourage women who have not received a cervical smear in the previous 2-year period to have a cervical smear performed when they attend the Infectious Disease Clinic, and will continue to notify the National Cervical Screening Programme that all women who are newly diagnosed with HIV infection should have an annual recall code attached to future cervical smear reports. We expect that these interventions will further increase the proportion of women with HIV infection in Auckland who receive an annual cervical smear.

  3. Sampling techniques for burbot in a western non-wadeable river

    USGS Publications Warehouse

    Klein, Z. B.; Quist, Michael C.; Rhea, D.T.; Senecal, A. C.

    2015-01-01

    Burbot, Lota lota (L.), populations are declining throughout much of their native distribution. Although numerous aspects of burbot ecology are well understood, less is known about effective sampling techniques for burbot in lotic systems. Occupancy models were used to estimate the probability of detection () for three gears (6.4- and 19-mm bar mesh hoop nets, night electric fishing), within the context of various habitat characteristics. During the summer, night electric fishing had the highest estimated detection probability for both juvenile (, 95% C.I.; 0.35, 0.26–0.46) and adult (0.30, 0.20–0.41) burbot. However, small-mesh hoop nets (6.4-mm bar mesh) had similar detection probabilities to night electric fishing for both juvenile (0.26, 0.17–0.36) and adult (0.27, 0.18–0.39) burbot during the summer. In autumn, a similar overlap between detection probabilities was observed for juvenile and adult burbot. Small-mesh hoop nets had the highest estimated probability of detection for both juvenile and adult burbot (0.46, 0.33–0.59), whereas night electric fishing had a detection probability of 0.39 (0.28–0.52) for juvenile and adult burbot. By using detection probabilities to compare gears, the most effective sampling technique can be identified, leading to increased species detections and more effective management of burbot.

  4. The rate of sputum smear-positive tuberculosis after treatment default in a high-burden setting: a retrospective cohort study.

    PubMed

    Marx, Florian M; Dunbar, Rory; Enarson, Donald A; Beyers, Nulda

    2012-01-01

    High rates of recurrent tuberculosis after successful treatment have been reported from different high burden settings in Sub-Saharan Africa. However, little is known about the rate of smear-positive tuberculosis after treatment default. In particular, it is not known whether or not treatment defaulters continue to be or become again smear-positive and thus pose a potential for transmission of infection to others. To investigate, in a high tuberculosis burden setting, the rate of re-treatment for smear-positive tuberculosis among cases defaulting from standardized treatment compared to successfully treated cases. Retrospective cohort study among smear-positive tuberculosis cases treated between 1996 and 2008 in two urban communities in Cape Town, South Africa. Episodes of re-treatment for smear-positive tuberculosis were ascertained via probabilistic record linkage. Survival analysis and Poisson regression were used to compare the rate of smear-positive tuberculosis after treatment default to that after successful treatment. A total of 2,136 smear-positive tuberculosis cases were included in the study. After treatment default, the rate of re-treatment for smear-positive tuberculosis was 6.86 (95% confidence interval [CI]: 5.59-8.41) per 100 person-years compared to 2.09 (95% CI: 1.81-2.41) after cure (adjusted Hazard Ratio [aHR]: 3.97; 95% CI: 3.00-5.26). Among defaulters, the rate was inversely associated with treatment duration and sputum conversion prior to defaulting. Smear grade at start of the index treatment episode (Smear3+: aHR 1.61; 95%CI 1.11-2.33) was independently associated with smear-positive tuberculosis re-treatment, regardless of treatment outcome. In this high-burden setting, there is a high rate of subsequent smear-positive tuberculosis after treatment default. Treatment defaulters are therefore likely to contribute to the pool of infectious source cases in the community. Our findings underscore the importance of preventing treatment default, as a means of successful tuberculosis control in high-burden settings.

  5. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a containment level-III laboratory as part of a Laboratory Risk Assessment Program.

    PubMed

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-24

    In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating/chemical fixation) may not consistently kill MTB organisms. An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80 degrees C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in house biosafety-validated practices with the aim of protecting laboratory workers conducting these procedures.

  6. Significance of DNA Replication Licensing Proteins (MCM2, MCM5 and CDC6), p16 and p63 as Markers of Premalignant Lesions of the Uterine Cervix: Its Usefulness to Predict Malignant Potential

    PubMed Central

    Saritha, VN; Veena, VS; Krishna, KM Jagathnath; Somanathan, Thara; Sujathan, K

    2018-01-01

    Cervical cancer continues to be a leading cancer among women in many parts of the world. Nation-wide screening with the Pap smear has not been implemented in India due to the lack of adequately trained cytologists. Identification of biomarkers to predict malignant potential of the identified low risk lesions is essential to avoid excessive retesting and follow up. The current study analyzed the expression patterns of DNA replication licensing proteins, proliferation inhibitor protein p16INK4A and tumor suppresser protein p63 in cervical tissues and smears to assess the ability of these proteins to predict progression. Methods: Cervical smears and corresponding tissues were immunostained using mouse monoclonal antibodies against MCM2, MCM5, CDC6, p16 and p63. Smears were treated with a non-ionic surfactant sodium deoxycholate prior to immuno-cytochemistry. The standard ABC method of immunohistochemistry was performed using DAB as the chromogen. The immunostained samples were scored on a 0-3+ scale and staining patterns of smears were compared with those of tissue sections. Sensitivity and specificity for each of these markers were calculated taking histopathology as the gold standard. Result: All the markers were positive in malignant and dysplastic cells. MCM protein expression was found to be up-regulated in LSIL, HSIL and in malignancies to a greater extent than p16 as well as p63. CDC6 protein was preferentially expressed in high grade lesions and in invasive squamous cell carcinomas. A progressive increase in the expression of DNA replication licensing proteins in accordance with the grades of cervical intraepithelial lesion suggests these markers as significant to predict malignant potential of low grade lesions in cervical smears. Conclusion: MCMs and CDC6 can be applied as biomarkers to predict malignant potential of low grade lesions identified in screening programmes and retesting / follow up might be confined to those with high risk lesions alone so that overuse of resources can be safely avoided. PMID:29373905

  7. A Comparative SEM Investigation of Smear Layer Remaining on Dentinal Walls by Three Rotary NiTi Files with Different Cross Sectional Designs in Moderately Curved Canals

    PubMed Central

    Kakkar, Pooja; Vats, Asit

    2015-01-01

    Objective: The objective of this study was to compare the smear layer formed on root canal walls during canal preparation of extracted human teeth by Twisted, Mtwo, and ProTaper rotary nickel titanium instruments. Materials and Methods: Sixty single rooted human premolar teeth with root curvature <250 were selected and randomly divided into three Groups (n= 20 teeth per Group). Three types of rotary nickel titanium instruments were used, Twisted (SybronEndo, Orange, CA, USA), Mtwo (VDW, Munich, Germany) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) according to manufacturer’s instructions to instrument the root canals. Irrigation for all groups was performed after each instrument change with 3ml of 3% sodium hypochlorite followed by Glyde (File Prep, Dentsply, Maillefer, Ballaigues, Switzerland) as chelator paste and lubricant. Three different areas (coronal, middle and apical thirds) of the root canal were evaluated using scanning electron microscopy (SEM). The canal wall of each sample was assessed and compared using a predefined scale for the presence or absence of smear layer. Data were analysed statistically using ANOVA and Tukey HSD test Results: All three groups showed statistically significant more smear layer in the apical thirds of the canal as compared to the coronal and middle thirds (p<0.001). Mtwo rotary file system produced significantly less smear layer (p<0.001) compared to Twisted and ProTaper rotary instruments in the apical portion. Twisted Files resulted in less smear layer formation in the apical thirds of the canal compared to ProTaper rotary instruments but were statistically insignificant. Conclusion: Completely clean root canals were not found after instrumentation with any of the three instruments. Under the confines of this study Mtwo instruments produced significantly cleaner dentin wall surfaces throughout the canal length in comparison to Twisted and ProTaper rotary files. Twisted Files proved to be comparable to ProTaper rotary instruments with respect to canal cleanliness in the apical thirds of the root canal. PMID:25954704

  8. Factors Associated with a Lack of Knowledge of Performing Breast Self-Examination and Unawareness of Cervical Cancer Screening Services: Evidence from the 2015 Egypt Health Issues Survey

    PubMed

    Al-Rifai, Rami H.; Loney, Tom

    2017-10-26

    Background: The incidence of breast and cervical cancers is growing rapidly among Egyptian women. In this context, we assessed the prevalence of, and factors associated with the lack of knowledge among Egyptian females of performing breast self–examination (BSE) and unawareness of cervical smear cancer screening services. Methods: Secondary data analysis was performed on a representative population-based sample of 7,518 Egyptian females aged 15–59 years from the 2015 Egypt Health Issues Survey (EHIS). Crude and adjusted odds ratios (aOR) were used to explore the relationship between sociodemographic variables and having a lack of knowledge of performing BSE or unaware of cervical smear cancer screening service amongst 6,572 and 6,942 Egyptian females aged 21–59 years, respectively. Results: Mean age of females was 36.9 years with 62% aged between 21–39 years. The proportion of women with a lack of knowledge of performing BSE or who were unaware of cervical smear cancer screening service was 87.4% and 92.3%, respectively. After adjusting for potential confounding of sociodemographic and obstetric characteristics, young women aged 21–29 years (P<0.001), primary education or below (P<0.001), residing in rural areas (aOR, 1.37 and 1.48, P=0.001), accessing different media outlets “not at all or less than once a week” (aOR, 2.81 and 1.46, P≤0.05), were associated with a greater likelihood of being with lack knowledge of performing BSE or being unaware of cervical smear cancer screening services. Conclusions: In a country burdened with breast and cervical cancers, the majority of Egyptian women have a lack of knowledge on how to perform BSE or were unaware of the available cervical smear cancer screening services. Robust health campaigns are warranted to raise public knowledge of the method of BSE and of cervical smear cancer screening services, especially amongst females aged less than 30 years, with low levels of education, or those living in rural areas. Creative Commons Attribution License

  9. Failure of imidocarb dipropionate to eliminate Hepatozoon canis in naturally infected dogs based on parasitological and molecular evaluation methods.

    PubMed

    Sasanelli, Mariateresa; Paradies, Paola; Greco, Beatrice; Eyal, Osnat; Zaza, Valeria; Baneth, Gad

    2010-08-04

    The efficacy of imidocarb dipropionate for the treatment of Hepatozoon canis infection was studied in three naturally infected asymptomatic dogs followed longitudinally over 8 months. Response to treatment was followed by monitoring blood counts, parasitemia levels in blood, parasite in concentrated buffy-coat smears and by PCR. The dogs were initially treated with a low dose of 3 mg/kg imidocarb dipropionate twice a month and when parasitemia persisted after five treatments, with the regular dose of 6 mg/kg. In one dog, H. canis gamonts were no longer detectable by blood and buffy-coat microscopy after 2 months of therapy with 6 mg/kg while in the two other dogs gamonts were intermittently found in blood but persistently detectable in buffy-coat smears during the whole study period. Furthermore, combined therapy with doxycycline monohydrate administered at 10 mg/kg/day PO for 4 weeks also failed to eliminate H. canis. PCR revealed that parasite DNA was present in the blood of all dogs at all sampling dates regardless of treatment refuting the effectiveness of treatment suggested by negative blood microscopy. Detection of H. canis in buffy coat was found to be twice as sensitive than by blood smear and detection by PCR was even more sensitive revealing infection in eight samples (16% of total samples) negative by blood and buffy-coat microscopy. In conclusion, imidocarb dipropionate was not effective in eliminating H. canis from dogs treated repeatedly over 8 months. Microscopical detection is not sufficient for the evaluation of treatment response in H. canis infection and follow up by molecular techniques is recommended. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Meatal Swabs Contain Less Cellular Material and Are Associated with a Decrease in Gram Stain Smear Quality Compared to Urethral Swabs in Men.

    PubMed

    Jordan, Stephen J; Schwebke, Jane R; Aaron, Kristal J; Van Der Pol, Barbara; Hook, Edward W

    2017-07-01

    Urethral swabs are the samples of choice for point-of-care Gram stain testing to diagnose Neisseria gonorrhoeae infection and nongonococcal urethritis (NGU) in men. As an alternative to urethral swabs, meatal swabs have been recommended for the collection of urethral discharge to diagnose N. gonorrhoeae and Chlamydia trachomatis infection in certain populations by nucleic acid amplification testing (NAAT), as they involve a less invasive collection method. However, as meatal swabs could be sampling a reduced surface area and result in fewer collected epithelial cells compared to urethral swabs, the adequacy of meatal swab specimens to collect sufficient cellular material for Gram stain testing remains unknown. We enrolled 66 men who underwent either urethral or meatal swabbing and compared the cellular content and Gram stain failure rate. We measured the difference in swab cellular content using the Cepheid Xpert CT/NG sample adequacy control crossing threshold (SAC CT ) and determined the failure rate of Gram stain smears (GSS) due to insufficient cellular material. In the absence of discharge, meatal smears were associated with a significant reduction in cellular content ( P = 0.0118), which corresponded with a GSS failure rate significantly higher than that for urethral swabs (45% versus 3%, respectively; P < 0.0001). When discharge was present, there was no difference among results from urethral and meatal swabs. Therefore, if GSS testing is being considered for point-of-care diagnosis of N. gonorrhoeae infection or NGU in men, meatal swabs should be avoided in the absence of a visible discharge. Copyright © 2017 American Society for Microbiology.

  11. Prevalence and molecular characterization of Cryptosporidium species in cattle and buffalo calves in Mumbai region of India.

    PubMed

    Hingole, A C; Gudewar, J G; Pednekar, R P; Gatne, M L

    2017-03-01

    Faecal samples of cattle and buffaloes of Mumbai region collected between November 2012 to June 2013 were analysed by conventional and molecular tools to note the prevalence of cryptosporidiosis and species involved in the infection. Conventional analysis viz., direct faecal smear examination, faecal smear examination after normal saline sedimentation, Sheather's floatation and Sheather's floatation sedimentation smear methods demonstrated oocysts of Cryptosporidium in 141 (36.06 %) of 391 samples with higher occurrence in buffaloes (36.99 %) than cattle (34.48 %). Diarrhoeic loose faeces showed higher prevalence (42.07 %) than apparently normal faeces (31.72 %) irrespective of the host species. When data were arranged as per age groups viz., calves of 0-1 month, 1-2 months, 2-3 months and adults, the highest prevalence was noted in the youngest group (47.12 %) declining gradually with the advancing age with lowest (6.25 %) in adults indicating inverse correlation between prevalence rate and age of the host. These differences were statistically significant in case of buffaloes. Cryptosporidium andersoni was tentatively identified by morphometric analysis. By employing molecular tools like nested PCR, PCR-RFLP and sequence analysis of few samples showed good correlation in the identification of species of Cryptosporidium involved in the infection and demonstrated occurrence of C. parvum , C. ryanae and C. bovis. Thus all the four commonly occurring bovine species of Cryptosporidium were encountered in the study area which appears to be a first record reporting the occurrence of Cryptosporidium with species level identification in large ruminants from Western region of India. Additionally, the public health significance of C. parvum was also discussed in light of epidemiological factors pertaining to the region.

  12. Data-driven sampling method for building 3D anatomical models from serial histology

    NASA Astrophysics Data System (ADS)

    Salunke, Snehal Ulhas; Ablove, Tova; Danforth, Theresa; Tomaszewski, John; Doyle, Scott

    2017-03-01

    In this work, we investigate the effect of slice sampling on 3D models of tissue architecture using serial histopathology. We present a method for using a single fully-sectioned tissue block as pilot data, whereby we build a fully-realized 3D model and then determine the optimal set of slices needed to reconstruct the salient features of the model objects under biological investigation. In our work, we are interested in the 3D reconstruction of microvessel architecture in the trigone region between the vagina and the bladder. This region serves as a potential avenue for drug delivery to treat bladder infection. We collect and co-register 23 serial sections of CD31-stained tissue images (6 μm thick sections), from which four microvessels are selected for analysis. To build each model, we perform semi-automatic segmentation of the microvessels. Subsampled meshes are then created by removing slices from the stack, interpolating the missing data, and re-constructing the mesh. We calculate the Hausdorff distance between the full and subsampled meshes to determine the optimal sampling rate for the modeled structures. In our application, we found that a sampling rate of 50% (corresponding to just 12 slices) was sufficient to recreate the structure of the microvessels without significant deviation from the fullyrendered mesh. This pipeline effectively minimizes the number of histopathology slides required for 3D model reconstruction, and can be utilized to either (1) reduce the overall costs of a project, or (2) enable additional analysis on the intermediate slides.

  13. Comparative Study of GeneXpert with ZN Stain and Culture in Samples of Suspected Pulmonary Tuberculosis

    PubMed Central

    Bajaj, Ashish; Bhatia, Vinay; Dutt, Sarjana

    2016-01-01

    Introduction Tuberculosis remains one of the deadliest communicable diseases. There are number of tests available for the diagnosis of tuberculosis but conventional microscopy has low sensitivity and culture although gold standard, but takes longer time for positivity. On the other side, Nucleic acid amplification techniques due to its rapidity and sensitivity not only help in early diagnosis and management of tuberculosis especially in patients with high clinical suspicion like immunocompromised patients, history of contact with active tuberculosis patient etc., but also curtail the transmission of the disease. Aim To evaluate the sensitivity, specificity, positive predictive value and negative predictive value of Nucleic acid amplification assay (GeneXpert) using respiratory samples in patients with suspected pulmonary tuberculosis and compare with AFB smear microscopy (Ziehl Neelsen stain) and Acid Fast Bacilli (AFB) culture. Materials and Methods We retrospectively reviewed the respiratory samples of suspected pulmonary tuberculosis (including Bronchoalveolar lavage and sputum) of 170 patients from Jan 2015 to Nov 2015 for ZN stain, culture and GeneXpert (Xpert® MTB/Rif assay). The sensitivity, specificity, PPV and NPV of GeneXpert and ZN microscopy were calculated using Liquid culture of Mycobacterium tuberculosis as gold standard. Results A total of 170 patient samples were evaluated in final analysis. Of these, 14 samples were positive by all three methods used in our study. The overall sensitivity, specificity, PPV and NPV of GeneXpert were 86.8%, 93.1%, 78.5% and 96% respectively and for BAL sample, 81.4%, 93.4%, 73.3% and 95.7% respectively. The overall sensitivity and specificity of AFB smear microscopy were 22.2%, % and 78.5% respectively and for BAL sample 22.2% and 100% respectively. For AFB negative samples sensitivity and specificity were 79.1% and 93.1% respectively. Conclusion GeneXpert has a higher sensitivity than AFB smear microscopy in respiratory samples. GeneXpert can be a useful tool for early diagnosis of patients with high clinical suspicion of pulmonary tuberculosis. Positive GeneXpert, but culture negative results should be read cautiously and be well correlated with clinical and treatment history of the patient. The other major advantage of Gene Xpert is that it simultaneously detects Rifampicin resistance and especially beneficial in patient with MDR and HIV associated tuberculosis and should be studied further. PMID:27437212

  14. Evaluation of the GeneXpert MTB/RIF assay on extrapulmonary and respiratory samples other than sputum: a low burden country experience.

    PubMed

    Pandey, Sushil; Congdon, Jacob; McInnes, Bradley; Pop, Alina; Coulter, Christopher

    2017-01-01

    The aim of this study was to assess the performance of the GeneXpert MTB/RIF assay on extrapulmonary (EP) and respiratory (non-sputum) clinical samples of patients suspected of having tuberculosis (TB) from Queensland, Australia. A total of 269 EP and respiratory (non-sputum) clinical samples collected from Qld patients who were suspected of having TB were subjected to the GeneXpert MTB/RIF analysis, Ziehl-Neelsen (ZN) staining, Mycobacterium tuberculosis (MTB) culture and drug susceptibility testing. Phenotypic and genotypic data were compared. The overall performance analysis of the GeneXpert MTB/RIF assay for detection of MTB complex demonstrated sensitivity of 89%, specificity of 95%, PPV of 89% and NPV of 95% using culture as a reference standard. The GeneXpert MTB/RIF analysis of acid-fast bacilli (AFB) smear positive samples and AFB smear negative samples showed sensitivities of 100% and 77%, respectively. Looking at individual EP and respiratory (non-sputum) sample types, the sensitivity ranged from 60% to 100% although the specificity ranged from 33% to 100% with the specificity of lymph node tissue biopsy being the lowest. The GeneXpert MTB/RIF assay detected 11% more TB cases than culture and 27% more cases than ZN microscopy. Due to insufficient numbers of presenting rifampicin resistance cases, performance analysis of the GeneXpert MTB/RIF assay on rifampicin resistance could not be carried out. The GeneXpert MTB/RIF assay is potentially valuable for TB diagnosis in the majority of the EP and respiratory (other than sputum) samples in our setting. Although the GeneXpert MTB/RIF assay provides rapid diagnostic results, the overall sensitivity to rule out the disease is suboptimal for some specimen types. Performance varied according to specimen type and AFB smear status. The sensitivity and specificity of lymph node tissue was 63% and 33%. Care must be taken when using the GeneXpert MTB/RIF assay for detection of MTB in lymph node tissue samples. All samples should be cultured regardless of the GeneXpert MTB/RIF assay result. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.

  15. Locally-smeared operator product expansions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monahan, Christopher; Orginos, Kostantinos

    2014-12-01

    We propose a "locally-smeared Operator Product Expansion" (sOPE) to decompose non-local operators in terms of a basis of locally-smeared operators. The sOPE formally connects nonperturbative matrix elements of smeared degrees of freedom, determined numerically using the gradient flow, to non-local operators in the continuum. The nonperturbative matrix elements do not suffer from power-divergent mixing on the lattice, provided the smearing scale is kept fixed in the continuum limit. The presence of this smearing scale prevents a simple connection to the standard operator product expansion and therefore requires the construction of a two-scale formalism. We demonstrate the feasibility of our approachmore » using the example of real scalar field theory.« less

  16. Breath-based biomarkers for tuberculosis

    NASA Astrophysics Data System (ADS)

    Kolk, Arend H. J.; van Berkel, Joep J. B. N.; Claassens, Mareli M.; Walters, Elisabeth; Kuijper, Sjoukje; Dallinga, Jan W.; van Schooten, Fredrik-Jan

    2012-06-01

    We investigated the potential of breath analysis by gas chromatography - mass spectrometry (GC-MS) to discriminate between samples collected prospectively from patients with suspected tuberculosis (TB). Samples were obtained in a TB endemic setting in South Africa where 28% of the culture proven TB patients had a Ziehl-Neelsen (ZN) negative sputum smear. A training set of breath samples from 50 sputum culture proven TB patients and 50 culture negative non-TB patients was analyzed by GC-MS. A classification model with 7 compounds resulted in a training set with a sensitivity of 72%, specificity of 86% and accuracy of 79% compared with culture. The classification model was validated with an independent set of breath samples from 21 TB and 50 non-TB patients. A sensitivity of 62%, specificity of 84% and accuracy of 77% was found. We conclude that the 7 volatile organic compounds (VOCs) that discriminate breath samples from TB and non-TB patients in our study population are probably host-response related VOCs and are not derived from the VOCs secreted by M. tuberculosis. It is concluded that at present GC-MS breath analysis is able to differentiate between TB and non-TB breath samples even among patients with a negative ZN sputum smear but a positive culture for M. tuberculosis. Further research is required to improve the sensitivity and specificity before this method can be used in routine laboratories.

  17. Why minimally invasive skin sampling techniques? A bright scientific future.

    PubMed

    Wang, Christina Y; Maibach, Howard I

    2011-03-01

    There is increasing interest in minimally invasive skin sampling techniques to assay markers of molecular biology and biochemical processes. This overview examines methodology strengths and limitations, and exciting developments pending in the scientific community. Publications were searched via PubMed, the U.S. Patent and Trademark Office Website, the DermTech Website and the CuDerm Website. The keywords used were noninvasive skin sampling, skin stripping, skin taping, detergent method, ring method, mechanical scrub, reverse iontophoresis, glucose monitoring, buccal smear, hair root sampling, mRNA, DNA, RNA, and amino acid. There is strong interest in finding methods to access internal biochemical, molecular, and genetic processes through noninvasive and minimally invasive external means. Minimally invasive techniques include the widely used skin tape stripping, the abrasion method that includes scraping and detergent, and reverse iontophoresis. The first 2 methods harvest largely the stratum corneum. Hair root sampling (material deeper than the epidermis), buccal smear, shave biopsy, punch biopsy, and suction blistering are also methods used to obtain cellular material for analysis, but involve some degree of increased invasiveness and thus are only briefly mentioned. Existing and new sampling methods are being refined and validated, offering exciting, different noninvasive means of quickly and efficiently obtaining molecular material with which to monitor bodily functions and responses, assess drug levels, and follow disease processes without subjecting patients to unnecessary discomfort and risk.

  18. Smartphone based hand-held quantitative phase microscope using the transport of intensity equation method.

    PubMed

    Meng, Xin; Huang, Huachuan; Yan, Keding; Tian, Xiaolin; Yu, Wei; Cui, Haoyang; Kong, Yan; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-12-20

    In order to realize high contrast imaging with portable devices for potential mobile healthcare, we demonstrate a hand-held smartphone based quantitative phase microscope using the transport of intensity equation method. With a cost-effective illumination source and compact microscope system, multi-focal images of samples can be captured by the smartphone's camera via manual focusing. Phase retrieval is performed using a self-developed Android application, which calculates sample phases from multi-plane intensities via solving the Poisson equation. We test the portable microscope using a random phase plate with known phases, and to further demonstrate its performance, a red blood cell smear, a Pap smear and monocot root and broad bean epidermis sections are also successfully imaged. Considering its advantages as an accurate, high-contrast, cost-effective and field-portable device, the smartphone based hand-held quantitative phase microscope is a promising tool which can be adopted in the future in remote healthcare and medical diagnosis.

  19. Dried Blood Spots for qPCR Diagnosis of Acute Bartonella bacilliformis Infection

    PubMed Central

    Smit, Pieter W.; Peeling, Rosanna W.; Garcia, Patricia J.; Torres, Lorena L.; Pérez-Lu, José E.; Moore, David; Mabey, David

    2013-01-01

    Bartonella bacilliformis is the etiological agent of a life-threatening illness. Thin blood smear is the most common diagnostic method for acute infection in endemic areas of Peru but remains of limited value because of low sensitivity. The aim of this study was to adapt a B. bacilliformis-specific real-time polymerase chain reaction (PCR) assay for use with dried blood spots (DBS) as a sampling method and assess its performance and use for the diagnosis and surveillance of acute Bartonella infection. Only two of 65 children (3%) that participated in this study had positive blood smears for B. bacilliformis, whereas 16 (including these two) were positive by PCR performed on DBS samples (24.6%). The use of DBS in combination with B. bacilliformis-specific PCR could be a useful tool for public health in identifying and monitoring outbreaks of infection and designing control programs to reduce the burden of this life-threatening illness. PMID:24043691

  20. Occurrence of Cryptosporidium oocysts in Wrinkled Hornbill and other birds in the Kuala Lumpur National Zoo.

    PubMed

    Rohela, M; Lim, Y A L; Jamaiah, I; Khadijah, P Y Y; Laang, S T; Nazri, M H Mohd; Nurulhuda, Z

    2005-01-01

    The occurrence of a coccidian parasite, Cryptosporidium, among birds in the Kuala Lumpur National Zoo was investigated in this study. A hundred bird fecal samples were taken from various locations of the zoo. Fecal smears prepared using direct smear and formalin ethyl acetate concentration technique were stained with modified Ziehl-Neelsen stain. Samples positive for Cryptosporidium with Ziehl-Neelsen stain were later confirmed using the immunofluorescence technique and viewed under the epifluorescence microscope. Six species of bird feces were confirmed positive with Cryptosporidium oocysts. They included Wrinkled Hornbill (Aceros corrugatus), Great Argus Pheasant (Argusianus argus), Black Swan (Cygnus atratus), Swan Goose (Anser cygnoides), Marabou Stork (Leptoptilos crumeniferus), and Moluccan Cockatoo (Cacatua moluccencis). These birds were located in the aviary and lake, with the Moluccan Cockatoo routinely used as a show bird. Results obtained in this study indicated that animal sanctuaries like zoos and bird parks are important sources of Cryptosporidium infection to humans, especially children and other animals.

  1. Cytology smears as diagnostic material for EGFR gene testing in non-small cell lung cancer.

    PubMed

    Powrózek, Tomasz; Krawczyk, Paweł; Pankowski, Juliusz; Reszka, Katarzyna; Jakubiak, Magdalena; Obrochta, Anna; Wojas-Krawczyk, Kamila; Buczkowski, Jarosław; Milanowski, Janusz

    2015-11-14

    Cytology smears can be effectively used for EGFR mutation testing in the qualification of NSCLC patients for EGFR tyrosine kinase inhibitor therapy. However, tissue specimens are preferred for EGFR mutation analysis. The aim of this study was to estimate the effectiveness of the real-time PCR method for EGFR testing in histology and cytology materials obtained simultaneously from NSCLC patients. Fourteen adenocarcinoma patients with EGFR-mutation-positive primary tumor tissues were included in the study. Corresponding cytological smears of metastatic lymph nodes obtained by EBUS-TBNA were examined. EGFR Mutation Analysis Kit (EntroGen, USA) and real-time PCR (m2000rt system, Abbott, USA) were used for EGFR mutation analysis in both types of material. In primary tumor tissues, 12 deletions in exon 19 and 2 substitutions in exon 21 (L858R mutation) of the EGFR gene were found. Except for 1 deletion in exon 19, the same EGFR gene mutations were detected in all corresponding cytology samples. The percentage of tumor cells, DNA concentration, percentage of mutated DNA as well as ΔCt values were similar in cytology slides and histology material. In both types of materials, no significant correlations were found between the percentage of tumor cells and the percentage of mutated DNA nor between the DNA concentration and the percentage of mutated DNA. We demonstrated the high effectiveness of a sensitive real-time PCR method in EGFR gene mutation detection in cytology smears.

  2. Morphological analysis of red blood cells by polychromatic interference microscopy of thin films

    NASA Astrophysics Data System (ADS)

    Dyachenko, A. A.; Malinova, L. I.; Ryabukho, V. P.

    2016-11-01

    Red blood cells (RBC) distribution width (RDW) is a promising hematological parameter with broadapplications in clinical practice; in various studies RDWhas been shown to be associated with increased risk of heart failure (HF) in general population. It predicts mortality and other major adverse events in HF patients. In this report new method of RDWmeasurement is presented. It's based on interference color analysis of red blood cells in blood smear and further measurement of its optical thickness. Descriptive statistics of the of the RBC optical thickness distribution in a blood smear were used for RDW estimation in every studied sample. Proposed method is considered to be avoiding type II errors and minimizing the variability of measured RDW.

  3. Rates of abnormalities and infectious agents in cervical smears from female inmates in Texas: comparison with private and university clinic patients.

    PubMed

    Logrono, R; Wong, J Y

    1999-09-01

    Inmates are generally considered a high-risk population for gynecologic neoplasia and sexually transmitted diseases. Cervical smears from prisoners of the Texas Department of Corrections (TDC) were expected initially to have higher rates of cellular abnormalities and infectious agents than do smears from the general population. The cytologic findings from 25,522 TDC gynecologic smears were compared with those of 6883 cases from The University of Texas Medical Branch (UTMB) affiliated physician private clinics, and with 56,178 from the UTMB hospital clinics. The period of study was from September 1995 to February 1998. This study revealed a 5.23% higher rate of abnormalities for TDC gynecologic smears as compared with that for the private clinic smears. However, the TDC rate of abnormalities was unexpectedly 1.08% lower than that for the UTMB clinic smears. These unexpected findings were probably the result of a more selected high-risk population referred to the UTMB clinics. The TDC smears showed also the highest incidence of trichomoniasis.

  4. High resolution computational on-chip imaging of biological samples using sparsity constraint (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Rivenson, Yair; Wu, Chris; Wang, Hongda; Zhang, Yibo; Ozcan, Aydogan

    2017-03-01

    Microscopic imaging of biological samples such as pathology slides is one of the standard diagnostic methods for screening various diseases, including cancer. These biological samples are usually imaged using traditional optical microscopy tools; however, the high cost, bulkiness and limited imaging throughput of traditional microscopes partially restrict their deployment in resource-limited settings. In order to mitigate this, we previously demonstrated a cost-effective and compact lens-less on-chip microscopy platform with a wide field-of-view of >20-30 mm^2. The lens-less microscopy platform has shown its effectiveness for imaging of highly connected biological samples, such as pathology slides of various tissue samples and smears, among others. This computational holographic microscope requires a set of super-resolved holograms acquired at multiple sample-to-sensor distances, which are used as input to an iterative phase recovery algorithm and holographic reconstruction process, yielding high-resolution images of the samples in phase and amplitude channels. Here we demonstrate that in order to reconstruct clinically relevant images with high resolution and image contrast, we require less than 50% of the previously reported nominal number of holograms acquired at different sample-to-sensor distances. This is achieved by incorporating a loose sparsity constraint as part of the iterative holographic object reconstruction. We demonstrate the success of this sparsity-based computational lens-less microscopy platform by imaging pathology slides of breast cancer tissue and Papanicolaou (Pap) smears.

  5. Mesh quality oriented 3D geometric vascular modeling based on parallel transport frame.

    PubMed

    Guo, Jixiang; Li, Shun; Chui, Yim Pan; Qin, Jing; Heng, Pheng Ann

    2013-08-01

    While a number of methods have been proposed to reconstruct geometrically and topologically accurate 3D vascular models from medical images, little attention has been paid to constantly maintain high mesh quality of these models during the reconstruction procedure, which is essential for many subsequent applications such as simulation-based surgical training and planning. We propose a set of methods to bridge this gap based on parallel transport frame. An improved bifurcation modeling method and two novel trifurcation modeling methods are developed based on 3D Bézier curve segments in order to ensure the continuous surface transition at furcations. In addition, a frame blending scheme is implemented to solve the twisting problem caused by frame mismatch of two successive furcations. A curvature based adaptive sampling scheme combined with a mesh quality guided frame tilting algorithm is developed to construct an evenly distributed, non-concave and self-intersection free surface mesh for vessels with distinct radius and high curvature. Extensive experiments demonstrate that our methodology can generate vascular models with better mesh quality than previous methods in terms of surface mesh quality criteria. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Prevalence of Theileria annulata in dairy cattle in Nyala, South Darfur State, Sudan.

    PubMed

    Abaker, Ismail A; Salih, Diaeldin A; Haj, Lima M El; Ahmed, Rawia E; Osman, Manal M; Ali, Awadia M

    2017-12-01

    This study was conducted in dairy cattle in Nyala, South Darfur State, during the period from June to September 2015, to study the prevalence of bovine tropical theileriosis. Apparently, healthy cattle of different age groups, different breeds, and from both sexes were randomly selected from seven locations. Three age groups of cattle were selected, group one <1 year old, group two 1-3 years old, and group three older than 3 years. These cattle were indigenous and cross (Friesian X zebu). A total of 150 blood samples were collected for blood smears, blood in EDTA tubes, and serum samples as well as ticks infesting cattle. Three diagnostic techniques were used such as blood smear, indirect fluorescent antibody test (IFAT), and polymerase chain reaction (PCR). Of 150 samples, 11 (7.3%, 95% confidence interval [CI]: 9.1-5.5) were positive for Theileria spp. piroplasms in the blood smears, 70 (46.7%, 95% CI: 35.7-57.7) were positive for Theileria annulata antibodies in the IFAT, and of 100 samples, 39 (39%, 95% CI: 46.6-31.4) were positive for T. annulata using PCR. The prevalence of T. annulata was higher in indigenous breed than cross cattle by the three diagnostic techniques. The highest prevalence of T. annulata was recorded among cattle older than 3 years old. There were three genera and ten species of ticks found feeding on cattle. These were Rhipicephalus evertsi evertsi, Rhipicephalus decoloratus, Rhipicephalus annulatus, Hyalomma dromedrii, Hyalomma impeltatum, Hyalomma rufipes, Hyalomma anatolicum, Hyalomma truncatum, Amblyomma variegatum , and Amblyomma lepidum . The study concluded that tropical theileriosis is prevalent among dairy cattle in Nyala. H. anatolicum was found in very low numbers, suggesting other ticks may play a role in the transmission of the disease. Molecular characterization of T. annulata is recommended for accurate mapping of the disease and evaluates the magnitude problem of tropical theileriosis in South Darfur region.

  7. Prevalence of Theileria annulata in dairy cattle in Nyala, South Darfur State, Sudan

    PubMed Central

    Abaker, Ismail A.; Salih, Diaeldin A.; Haj, Lima M. El; Ahmed, Rawia E.; Osman, Manal M.; Ali, Awadia M.

    2017-01-01

    Aim: This study was conducted in dairy cattle in Nyala, South Darfur State, during the period from June to September 2015, to study the prevalence of bovine tropical theileriosis. Materials and Methods: Apparently, healthy cattle of different age groups, different breeds, and from both sexes were randomly selected from seven locations. Three age groups of cattle were selected, group one <1 year old, group two 1-3 years old, and group three older than 3 years. These cattle were indigenous and cross (Friesian X zebu). A total of 150 blood samples were collected for blood smears, blood in EDTA tubes, and serum samples as well as ticks infesting cattle. Three diagnostic techniques were used such as blood smear, indirect fluorescent antibody test (IFAT), and polymerase chain reaction (PCR). Results: Of 150 samples, 11 (7.3%, 95% confidence interval [CI]: 9.1-5.5) were positive for Theileria spp. piroplasms in the blood smears, 70 (46.7%, 95% CI: 35.7-57.7) were positive for Theileria annulata antibodies in the IFAT, and of 100 samples, 39 (39%, 95% CI: 46.6-31.4) were positive for T. annulata using PCR. The prevalence of T. annulata was higher in indigenous breed than cross cattle by the three diagnostic techniques. The highest prevalence of T. annulata was recorded among cattle older than 3 years old. There were three genera and ten species of ticks found feeding on cattle. These were Rhipicephalus evertsi evertsi, Rhipicephalus decoloratus, Rhipicephalus annulatus, Hyalomma dromedrii, Hyalomma impeltatum, Hyalomma rufipes, Hyalomma anatolicum, Hyalomma truncatum, Amblyomma variegatum, and Amblyomma lepidum. Conclusion: The study concluded that tropical theileriosis is prevalent among dairy cattle in Nyala. H. anatolicum was found in very low numbers, suggesting other ticks may play a role in the transmission of the disease. Molecular characterization of T. annulata is recommended for accurate mapping of the disease and evaluates the magnitude problem of tropical theileriosis in South Darfur region. PMID:29391689

  8. The value of mutational profiling of the cytocentrifugation supernatant fluid from fine-needle aspiration of pancreatic solid mass lesions.

    PubMed

    Deftereos, Georgios; Finkelstein, Sydney D; Jackson, Sara A; Ellsworth, Eric M G; Krishnamurti, Uma; Liu, Yulin; Silverman, Jan F; Binkert, Candy R; Ujevich, Beth A; Mohanty, Alok

    2014-04-01

    Fine-needle aspiration (FNA) of pancreatic solid masses can be significantly impacted by sampling variation. Molecular analysis of tumor DNA can be an aid for more definitive diagnosis. The aim of this study was to evaluate how molecular analysis of the cell-free cytocentrifugation supernatant DNA can help reduce sampling variability and increase diagnostic yield. Twenty-three FNA smears from pancreatic solid masses were performed. Remaining aspirates were rinsed for preparation of cytocentrifuged slides or cell blocks. DNA was extracted from supernatant fluid and assessed for DNA quantity spectrophotometrically and for amplifiability by quantitative PCR (qPCR). Supernatants with adequate DNA were analyzed for mutations using PCR/capillary electrophoresis for a broad panel of markers (KRAS point mutation by sequencing, microsatellite fragment analysis for loss of heterozygosity (LOH) of 16 markers at 1p, 3p, 5q, 9p, 10q, 17p, 17q, 21q, and 22q). In selected cases, microdissection of stained cytology smears and/or cytocentrifugation cellular slides were analyzed and compared. In all, 5/23 samples cytologically confirmed as adenocarcinoma showed detectable mutations both in the microdissected slide-based cytology cells and in the cytocentrifugation supernatant. While most mutations detected were present in both microdissected slides and supernatant fluid specimens, the latter showed additional mutations supporting greater sensitivity for detecting relevant DNA damage. Clonality for individual marker mutations was higher in the supernatant fluid than in microdissected cells. Cytocentrifugation supernatant fluid contains levels of amplifiable DNA suitable for mutation detection and characterization. The finding of additional detectable mutations at higher clonality indicates that supernatant fluid may be enriched with tumor DNA. Molecular analysis of the supernatant fluid could serve as an adjunct method to reduce sampling variability and increase diagnostic yield, especially in cases with a high clinical suspicion for malignancy and limited number of atypical cells in the smears.

  9. Smear layer-deproteinizing improves bonding of one-step self-etch adhesives to dentin.

    PubMed

    Thanatvarakorn, Ornnicha; Prasansuttiporn, Taweesak; Thittaweerat, Suppason; Foxton, Richard M; Ichinose, Shizuko; Tagami, Junji; Hosaka, Keiichi; Nakajima, Masatoshi

    2018-03-01

    Smear layer deproteinizing was proved to reduce the organic phase of smear layer covered on dentin surface. It was shown to eliminate hybridized smear layer and nanoleakage expression in resin-dentin bonding interface of two-step self-etch adhesive. This study aimed to investigate those effects on various one-step self-etch adhesives. Four different one-step self-etch adhesives were used in this study; SE One (SE), Scotchbond™ Universal (SU), BeautiBond Multi (BB), and Bond Force (BF). Flat human dentin surfaces with standardized smear layer were prepared. Smear layer deproteinizing was carried out by the application of 50ppm hypochlorous acid (HOCl) on dentin surface for 15s followed by Accel ® (p-toluenesulfinic acid salt) for 5s prior to adhesive application. No surface pretreatment was used as control. Microtensile bond strength (μTBS) and nanoleakage under TEM observation were investigated. The data were analyzed by two-way ANOVA and Tukey's post-hoc test and t-test at the significant level of 0.05. Smear layer deproteinizing significantly improved μTBS of SE, SU, and BB (p<0.001). Hybridized smear layer observed in control groups of SE, BB, and BF, and reticular nanoleakage presented throughout the hybridized complex in control groups of BB and BF were eliminated upon the smear layer deproteinizing. Smear layer deproteinizing by HOCl and Accel ® application could enhance the quality of dentin for bonding to one-step self-etch adhesives, resulting in the improving μTBS, eliminating hybridized smear layer and preventing reticular nanoleakage formation in resin-dentin bonding interface. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  10. Mixture of alkaline tetrasodium EDTA with sodium hypochlorite promotes in vitro smear layer removal and organic matter dissolution during biomechanical preparation.

    PubMed

    Tartari, T; Oda, D F; Zancan, R F; da Silva, T L; de Moraes, I G; Duarte, M A H; Bramante, C M

    2017-01-01

    The aim of this study was to determine the following: (i) the quantity of free chlorine in mixtures of equal proportions of sodium hypochlorite (NaOCl) with trisodium ethylenediaminetetraacetic acid (EDTAHNa 3 ) and alkaline tetrasodium ethylenediaminetetraacetic acid (EDTANa 4 ); (ii) organic matter dissolution; and (iii) the time necessary to remove the smear layer by these irrigants alone and when mixed. The solutions were mixed in a 1 : 1 ratio and then iodometrically titrated over time to determine the quantity of free available chlorine. The capability of organic matter dissolution by the solutions alone and the mixtures of irrigants was analysed by weighing bovine muscle tissue specimens before and after submission to the following groups (n = 10): G1 - 0.9% saline solution (control), G2 - 2.5% NaOCl, G3 - 17% EDTAHNa 3 , G4 - 10% EDTANa 4 , G5 - 20% EDTANa 4 , G6 - 5% NaOCl + 17% EDTAHNa 3 , G7 - 5% NaOCl + 10% EDTANa 4 and G8 - 5% NaOCl + 20% EDTANa 4 . The times necessary for smear layer removal were determinated on discs of bovine dentine with a standardized smear layer produced with SiC papers using a scanning electron microscope that did not require the samples to be sputter coated. The dentine discs were submitted to the same experimental groups previously described (n = 10) over several time periods, and the photomicrographs acquired were scored for the presence of smear layer. The parametric data of tissue dissolution were analysed using two-way anova and one-way anova with Tukey's post hoc tests (α < 0.05), whilst nonparametric data of smear layer removal were analysed by Friedman test (α < 0.05) and the Kruskal-Wallis test with Dunn's post hoc (α < 0.05). EDTAHNa 3 caused an almost complete and immediate loss of free available chlorine from NaOCl, whilst EDTANa 4 promoted a slow and concentrat-ion-dependent decline. The organic matter was not dissolved in the control group, EDTA groups or the mixture of NaOCl + 17% EDTAHNa 3 group (P > 0.05). NaOCl alone and the associations of NaOCl + EDTANa 4 dissolved tissue at all periods analysed (P < 0.05). The smear layer was not removed in the control and NaOCl groups (P > 0.05). The smear layer was removed at 1 min in the NaOCl + 17% EDTAHNa 3 group (P < 0.05); 2 min in 17% EDTAHNa 3 group (P < 0.05); and 5 min in 10% EDTANa 4 , 20% EDTANa 4 , 5% NaOCl + 10% EDTANa 4 and 5% NaOCl + 20% EDTANa 4 groups (P < 0.05). Alkaline EDTANa 4 was slower in removing the smear layer than EDTAHNa 3 , but when mixed with NaOCl during biomechanical canal preparation promoted organic matter dissolution and smear layer removal simultaneously. However, the mixing of NaOCl and EDTANa 4 should be performed immediately before use to prevent the reduction of free available chlorine. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. How mycorrhizal plant-soil interactions affect formation and degradation of soil organic matter in boreal forest

    NASA Astrophysics Data System (ADS)

    Adamczyk, Bartosz; Sietiö, Outi-Maaria; Ahvenainen, Anu; Strakova, Petra; Heinonsalo, Jussi

    2017-04-01

    Forest soil organic matter (SOM) contains more carbon (C) than all the flora and atmosphere combined and that is why C release as CO2 from SOM may have drastic consequences for climate globally. SOM is enormous C sink which has the potential to become C source (IPCC 2013). To predict long-term soil C storage and climate feedbacks we need profound understanding of dynamics and drivers of SOM decomposition. Ecosystem processes associated with C cycle are constrained by C and N interactions. At the level of ecosystem boreal forest is N-limited, as most of soil N is stored in recalcitrant organic form bound or complexed with soil compounds such as polyphenols. To improve N uptake, also from less available pools, plant species form symbioses with mycorrhizal fungi able to degrade recalcitrant N and sharing it with plants. As a feedback, plants provide to fungal symbiont assimilated C. Climate change through elevated CO2 level led to increases in photosynthesis which enhance the C flow belowground accelerating N uptake by plants also from more recalcitrant N pools. Increased SOM decomposition would possibly result also in increase of CO2 production from soil. Our field experiment was conducted at Hyytiälä forestry field station (SMEAR II, University of Helsinki) located in southern Finland (61°84'N, 24°26'E). In this 3-year long experiment, we discriminated SOM decomposition with different mesh bags filled with humus. These mesh bags allowed for the entrance of mycorrhiza and fine roots (1mm mesh size), or only mycorrhiza (50µm), or both were excluded (1µm). We followed changes in SOM content, N pools and enzymatic activity. The results suggests that plant-mycorrhiza interactions increase recalcitrant pool of organic N in SOM due to root-derived tannins, but mycorrhizal plants have still access to this N. Although mycorrhizal plant-soil interaction seems to strongly affect the formation of recalcitrant SOM, the net decomposition is not hindered by these chemical changes. This study underline that plant-soil feedbacks and especially soil chemistry behind this interaction are decisive factors for estimating changes in SOM decomposition rate.

  12. Molecular Pap smear: HPV genotype and DNA methylation of ADCY8, CDH8, and ZNF582 as an integrated biomarker for high-grade cervical cytology.

    PubMed

    Shen-Gunther, Jane; Wang, Chiou-Miin; Poage, Graham M; Lin, Chun-Lin; Perez, Luis; Banks, Nancy A; Huang, Tim Hui-Ming

    2016-01-01

    The Pap smear has remained the foundation for cervical cancer screening for over 70 years. With advancements in molecular diagnostics, primary high-risk human papillomavirus (hrHPV) screening has recently become an accepted stand-alone or co-test with conventional cytology. However, both diagnostic tests have distinct limitations. The aim of this study was to determine the association between HPV genotypes and cellular epigenetic modifications in three grades of cervical cytology for screening biomarker discovery. This prospective, cross-sectional study used residual liquid-based cytology samples for HPV genotyping and epigenetic analysis. Extracted DNA was subjected to parallel polymerase chain reactions using three primer sets (MY09/11, FAP59/64, E6-E7 F/B) for HPV DNA amplification. HPV+ samples were genotyped by DNA sequencing. Promoter methylation of four candidate tumor suppressor genes (adenylate cyclase 8 (ADCY8), cadherin 8, type 2 (CDH8), MGMT, and zinc finger protein 582 (ZNF582)) out of 48 genes screened was quantified by bisulfite-pyrosequencing of genomic DNA. Independent validation of methylation profiles was performed by analyzing data from cervical cancer cell lines and clinical samples from The Cancer Genome Atlas (TCGA). Two hundred seventy-seven quality cytology samples were analyzed. HPV was detected in 31/100 (31 %) negative for intraepithelial lesion or malignancy (NILM), 95/100 (95 %) low-grade squamous intraepithelial lesion (LSIL), and 71/77 (92 %) high-grade squamous intraepithelial lesion (HSIL) samples. The proportion of IARC-defined carcinogenic HPV types in sequenced samples correlated with worsening grade: NILM 7/29 (24 %), LSIL 53/92 (58 %), and HSIL 65/70 (93 %). Promoter methylation of ADCY8, CDH8, and ZNF582 was measured in 170 samples: NILM (N = 33), LSIL (N = 70), and HSIL (N = 67) also correlated with worsening grade. Similar hypermethylation patterns were found in cancer cell lines and TCGA samples. The combination of four biomarkers, i.e., HPV genotype and three-gene promoter methylation, predicted HSIL (AUC 0.89) better than HPV alone (AUC 0.74) by logistic regression and probabilistic modeling. HPV genotype and DNA methylation of ADCY8, CDH8, and ZNF582 are correlated with cytological grade. Collectively, these biomarkers may serve as a molecular classifier of Pap smears.

  13. Commercial Serological Antibody Detection Tests for the Diagnosis of Pulmonary Tuberculosis: A Systematic Review

    PubMed Central

    Steingart, Karen R; Henry, Megan; Laal, Suman; Hopewell, Philip C; Ramsay, Andrew; Menzies, Dick; Cunningham, Jane; Weldingh, Karin; Pai, Madhukar

    2007-01-01

    Background The global tuberculosis epidemic results in nearly 2 million deaths and 9 million new cases of the disease a year. The vast majority of tuberculosis patients live in developing countries, where the diagnosis of tuberculosis relies on the identification of acid-fast bacilli on unprocessed sputum smears using conventional light microscopy. Microscopy has high specificity in tuberculosis-endemic countries, but modest sensitivity which varies among laboratories (range 20% to 80%). Moreover, the sensitivity is poor for paucibacillary disease (e.g., pediatric and HIV-associated tuberculosis). Thus, the development of rapid and accurate new diagnostic tools is imperative. Immune-based tests are potentially suitable for use in low-income countries as some test formats can be performed at the point of care without laboratory equipment. Currently, dozens of distinct commercial antibody detection tests are sold in developing countries. The question is “do they work?” Methods and Findings We conducted a systematic review to assess the accuracy of commercial antibody detection tests for the diagnosis of pulmonary tuberculosis. Studies from all countries using culture and/or microscopy smear for confirmation of pulmonary tuberculosis were eligible. Studies with fewer than 50 participants (25 patients and 25 control participants) were excluded. In a comprehensive search, we identified 68 studies. The results demonstrate that (1) overall, commercial tests vary widely in performance; (2) sensitivity is higher in smear-positive than smear-negative samples; (3) in studies of smear-positive patients, Anda-TB IgG by enzyme-linked immunosorbent assay shows limited sensitivity (range 63% to 85%) and inconsistent specificity (range 73% to 100%); (4) specificity is higher in healthy volunteers than in patients in whom tuberculosis disease is initially suspected and subsequently ruled out; and (5) there are insufficient data to determine the accuracy of most commercial tests in smear microscopy–negative patients, as well as their performance in children or persons with HIV infection. Conclusions None of the commercial tests evaluated perform well enough to replace sputum smear microscopy. Thus, these tests have little or no role in the diagnosis of pulmonary tuberculosis. Lack of methodological rigor in these studies was identified as a concern. It will be important to review the basic science literature evaluating serological tests for the diagnosis of pulmonary tuberculosis to determine whether useful antigens have been described but their potential has not been fully exploited. Activities leading to the discovery of new antigens with immunodiagnostic potential need to be intensified. PMID:17564490

  14. 40 KG Sample of Fish-Clay from Stevns Klint, Denmark

    NASA Astrophysics Data System (ADS)

    Gwozdz, R.; Hansen, H. J.; Rasmussen, K. L.

    1992-07-01

    In March 1986 a 50-m-long exposure of the cliff at Stevns Klint fell down and exposed about 40 square meters of Fish Clay. Due to this extraordinary event we were able to pick by hand about 50 kg black KT boundary layer material. After drying, the material was homogenized using a wooden pestle and an agate mortar. The powdered material was sieved through 200 mesh nylon gauze. The fraction larger than 200 mesh was collected and powdered again in an agate mortar. After four repetitions the amount of material with grain size less than 200 mesh was about 40 kg. The fraction larger than 200 mesh was reduced to about 7 kg. The 40-kg powder was mixed in a rotating polyethylene drum for three weeks. The material was analyzed by instrumental neutron activation analysis, atomic absorption and X-ray fluorescence analysis for about 40 elements. INAA was made on 20 aliquots with weight about 300 mg, 20 aliquots with weight about 80 mg, and 30 with weights between 10 and 20 mg. The preliminary results show that our KT boundary sample (1) is very homogeneous, (2) is very close in composition to other K-T boundary clays analyzed by us or described in the literature, and (3) has an Ir concentration of 32 +- 2 ng/g. We hope that our Fish Clay sample (termed by us "Mesozoic Midnight") after analysis in other laboratories and by other analytical methods may qualify as reference material in analytical work on boundary clay material.

  15. A propagation method with adaptive mesh grid based on wave characteristics for wave optics simulation

    NASA Astrophysics Data System (ADS)

    Tang, Qiuyan; Wang, Jing; Lv, Pin; Sun, Quan

    2015-10-01

    Propagation simulation method and choosing mesh grid are both very important to get the correct propagation results in wave optics simulation. A new angular spectrum propagation method with alterable mesh grid based on the traditional angular spectrum method and the direct FFT method is introduced. With this method, the sampling space after propagation is not limited to propagation methods no more, but freely alterable. However, choosing mesh grid on target board influences the validity of simulation results directly. So an adaptive mesh choosing method based on wave characteristics is proposed with the introduced propagation method. We can calculate appropriate mesh grids on target board to get satisfying results. And for complex initial wave field or propagation through inhomogeneous media, we can also calculate and set the mesh grid rationally according to above method. Finally, though comparing with theoretical results, it's shown that the simulation result with the proposed method coinciding with theory. And by comparing with the traditional angular spectrum method and the direct FFT method, it's known that the proposed method is able to adapt to a wider range of Fresnel number conditions. That is to say, the method can simulate propagation results efficiently and correctly with propagation distance of almost zero to infinity. So it can provide better support for more wave propagation applications such as atmospheric optics, laser propagation and so on.

  16. Perceptions and concerns of women undergoing Pap smear examination in a tertiary care hospital of India.

    PubMed

    Tiwari, A; Kishore, J; Tiwari, A

    2011-01-01

    Cervical cancer is one of the major causes of deaths due to cancer among women in India. Pap smear is one of the best methods to detect early changes in cervix. However, there is lack of data on awareness level of women about Pap smear and various risk factors for cervical cancer. To study the awareness about various risk factors for cervical cancer, health-seeking behavior and hygienic practices among women and to assess the distress experienced by these women before the Pap smear examination. This cross-sectional study was carried out on women coming for a Pap smear examination in a tertiary teaching hospital in New Delhi. A pretested interview schedule was used to get information after obtaining their informed consent. Fifty-seven percent stated that they did not consult a doctor when they noticed the symptoms the first time. Sixty-one percent did not know what a cervical cancer is and a same percentage of women did not know what a Pap smear examination was. Older age group, Muslim and literate women had higher number of abnormal Pap smear results. Women who reported being stressed in their lives had higher number of abnormal smears as compared to women who claimed to lead a stress free life. Poor hygienic practices among these women from urban areas were also associated with abnormal Pap smear results. The study concluded that factors such as poor awareness, shyness, poor hygiene, and old age could be responsible for abnormal Pap smears and this needs special attention in cancer prevention activities of the government.

  17. Comparison of Pap smear screening results between Akha hill tribe and urban women in Chiang Rai province, Thailand.

    PubMed

    Kritpetcharat, Onanong; Wutichouy, Wiwat; Sirijaichingkul, Suchat; Kritpetcharat, Panutas

    2012-01-01

    Cervical cancer is an important woman's health problems worldwide, especially in low socio-economic countries. The aim of this study was to compare the Pap smear screening results between Akha hill tribe and urban women who live in Chiang Rai province, Thailand. Screening was conducted for 1,100 Akha women and 1,100 urban women who came to have the Pap smear at Chiangrai Prachanukroh Hospital and 1 private cytology laboratory from January to June 2008. The demographic characteristics and factors related to abnormal Pap smears of these women were gathered using closed model questionnaires. Abnormal Rap smears were defined according to the Bethesda 2001 system. The results showed that the prevalence of abnormal Pap smears was 12.2% in Akha women and 4.5% in urban women. The highest prevalence of Pap abnormalities was found in the 41-50 years age group in both populations (4.5% in Akha and 1.7% in urban women). In both populations, abnormal Pap smears were found in <21 years age groups. From the questionnaires, the possible risk factors related to the higher prevalence of abnormal Pap smears in Akha women were early age at marriage (≤17 years), high frequency pregnacies and high parity and no/low education level. In conclusion, cervical cancer control by education and early detection by Pap smear screening is necessary for hill tribe women. More Pap smear screening service units should be set to improve the coverage for the risk group women who got married in young age, especial in ethnic groups.

  18. Time to sputum conversion in smear positive pulmonary TB patients on category I DOTS and factors delaying it.

    PubMed

    Parikh, Raunak; Nataraj, Gita; Kanade, Swapna; Khatri, Vijay; Mehta, Preeti

    2012-08-01

    Sputum smear positive pulmonary tuberculosis patients expel infectious viable bacilli for a period following commencement of treatment. Patients on Directly Observed Treatment Shortcourse (DOTS) receive intermittent therapy with multidrug regimen. To determine the time to sputum smear and culture conversion following initiation of DOTS treatment and study the factors that influence it. A prospective study was undertaken at a tertiary care teaching hospital in Mumbai over a one year period on a cohort of 71 sputum smear positive patients on Category I DOTS treatment. Patients were followed up weekly for upto 20 weeks or until they underwent smear and culture conversion whichever was earlier. At each follow up, specimens were collected and processed for microscopy and culture using standard protocol. 60/71 [84.55%] patients completed the study. 56/60 [93.3%] patients underwent sputum smear and culture conversion. The median time to smear and culture conversion was end of 5th week [day 35] and 6 1/2 weeks [day 45] respectively. Univariate and stepwise regression analysis showed that patients who had cavitatory disease, high pretreatment smear grade and a past history of tuberculosis were more likely to undergo delayed or nonconversion [P < 0.05]. The time to sputum smear and culture conversion under DOTS is similar to previous antituberculosis regimens. Since viable bacilli continue to be expelled for upto two months, infection control measures should be maintained for such time. Patients with cavitatory disease, high pretreatment smear grade or a past history of tuberculosis need to be monitored more closely.

  19. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    PubMed

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  20. A Scanning Electron Microscope Evaluation of Smear Layer Removal and Antimicrobial Action of Mixture of Tetracycline, Acid and Detergent, Sodium Hypochlorite, Ethylenediaminetetraacetic Acid, and Chlorhexidine Gluconate: An In vitro Study.

    PubMed

    Charlie, K M; Kuttappa, M A; George, Liza; Manoj, K V; Joseph, Bobby; John, Nishin K

    2018-01-01

    The main objective is to evaluate the efficiency in removal of smear layer of mixture of tetracycline, acid and detergent (MTAD), sodium hypochlorite (NaOCl), ethylenediaminetetraacetic acid (EDTA) and chlorhexidine gluconate by scanning electron microscope (SEM) evaluation and also to evaluate the antimicrobial action of the same irrigants against standard culture strains of Enterococcus faecalis . This study included 60 extracted permanent teeth with single root canal. The sample was categorized into five groups with 12 teeth in each group. Root canals were enlarged till size 40 with K-files. One group was kept as control and irrigated only with saline. Other four groups used 5% NaOCl as irrigant during instrumentation and MTAD, 5% NaOCl, 17% EDTA, and 2% chlorhexidine gluconate as final rinse. Teeth were split and examined under SEM. To test the antibacterial action, the zone of inhibition method using agar plates was used. Obtained data were statistically analyzed by SPSS version 17 (SPSS Inc., Chicago, IL, USA). MTAD and 17% EDTA removed smear layer from all regions of the root canals. About 5% NaOCl and 2% chlorhexidine gluconate were ineffective in removing the smear layer. The mean zone of inhibition formed by the irrigants was in the following order; MTAD (40.5 mm), 2% chlorhexidine gluconate (29.375 mm), 17% EDTA (24.125 mm), 5% NaOCl (22.125 mm), and saline (zero). MTAD showed high smear layer removal efficacy, but no significant difference was found to that of 17% EDTA. As the dimensions of the zones of inhibition showed, MTAD has got highest antibacterial action against E. faecalis , followed by 2% chlorhexidine gluconate, 17% EDTA, and 5% NaOCl. However, the exact correlation of in vitro study results to clinical conditions is impossible due to the variables involved.

  1. The sensitivity and specificity of a urine based Rapid Diagnostic Test for the diagnosis of plasmodium falciparum in a malaria endemic area in Odisha, India.

    PubMed

    Samal, Ajit Gopal; Behera, Prativa Kumari; Mohanty, Akshay Kumar; Satpathi, Sanghamitra; Kumar, Abhishek; Panda, Rabi Ratna; Minz, Aruna Mukti; Mohanty, Sanjib; Samal, Abhijit; Van Der Pluijm, Rob W

    2017-10-01

    Rapid and accurate diagnosis is crucial in the treatment of malaria. Rapid Diagnostic Tests (RDTs) using blood have been recommended by the WHO as an acceptable method for the diagnosis of malaria. RDTs provide results quickly, is simple to use and easy to interpret. However, its use requires collection of blood by skin puncture. Hence the aim of the pilot study is to explore the sensitivity and specificity of RDTs using urine (collected non-invasively) for diagnosis of Plasmodium falciparum malaria and to assess the relation between parasite density in blood with HRP-2 Ag detection in urine. All fever cases admitted to Ispat General Hospital (IGH) Rourkela, India, during June 2012-March 2013 with a clinical diagnosis of malaria were examined for the presence of asexual forms of P. falciparum in peripheral blood smears. All smear positive febrile patients who met the eligibility criteria were enrolled. Smear negative fever cases were enrolled as control cases. RDTs were performed using both urine and blood samples by using commercially available blood specific kits. Sixty blood smear positive cases and 51 febrile blood smear negative cases were enrolled. Sensitivity and specificity of RDT urine were 86.67% (95%CI:75.83-93.09) and 94.12% (95%CI:84.08-97.98) respectively whereas those of RDT blood were 91.67% (95% CI: 81.93-96.39) and 98.04% (95% CI 89.7-99.65). The sensitivity of both RDT urine as well as RDT blood were found to be dependent on the level of parasitemia. Results of this study are promising. Larger studies are needed to assess whether RDTs using urine could serve as a practical, reliable method for the detection of P. falciparum in a non-invasive manner where invasive blood taking is less feasible.

  2. A real-time, quantitative PCR protocol for assessing the relative parasitemia of Leucocytozoon in waterfowl

    USGS Publications Warehouse

    Smith, Matthew M.; Schmutz, Joel A.; Apelgren, Chloe; Ramey, Andy M.

    2015-01-01

    Microscopic examination of blood smears can be effective at diagnosing and quantifying hematozoa infections. However, this method requires highly trained observers, is time consuming, and may be inaccurate for detection of infections at low levels of parasitemia. To develop a molecular methodology for identifying and quantifying Leucocytozoon parasite infection in wild waterfowl (Anseriformes), we designed a real-time, quantitative PCR protocol to amplify Leucocytozoon mitochondrial DNA using TaqMan fluorogenic probes and validated our methodology using blood samples collected from waterfowl in interior Alaska during late summer and autumn (n = 105). By comparing our qPCR results to those derived from a widely used nested PCR protocol, we determined that our assay showed high levels of sensitivity (91%) and specificity (100%) in detecting Leucocytozoon DNA from host blood samples. Additionally, results of a linear regression revealed significant correlation between the raw measure of parasitemia produced by our qPCR assay (Ct values) and numbers of parasites observed on blood smears (R2 = 0.694, P = 0.003), indicating that our assay can reliably determine the relative parasitemia levels among samples. This methodology provides a powerful new tool for studies assessing effects of haemosporidian infection in wild avian species.

  3. Split sample comparison of a liquid-based method and conventional smears in thyroid fine needle aspiration.

    PubMed

    Jung, Chan-Kwon; Lee, Ahwon; Jung, Eun-Sun; Choi, Yeong-Jin; Jung, So-Lyung; Lee, Kyo-Young

    2008-01-01

    To compare the efficacy of the SurePath (SP) vs. conventional smears (CS) in fine needle aspiration (FNA) of thyroid gland lesions. A total of 193 FNA cases with thyroid nodules were studied. Samples from ultrasound-guided FNA were split to prepare CS and SP slides. The diagnostic categories of unsatisfactory, benign, atypical and malignant were compared. Galectin-3 immunostaining was performed on SP slides. Some differences were found between the cytomorphology of CS and SP. SP slides showed more increased cellularity and more clustered tissue fragments. On SP slides, nuclear detail and nucleoli were more easily detected and nuclear irregularity was very useful for the diagnosis of papillary carcinoma. SP showed a trend toward a lower proportion of atypical category. The overall sensitivity of FNA in diagnosing thyroid neoplasm was 90.9% for CS and 93.9% for SP. Most lesions (73%) diagnosed as papillary carcinoma after surgery showed positive staining of galectin-3. The SP method showed easy evaluation of cytomorphologic features and consistent specimen quality and appeared to be more useful in diagnosing the suspicious cases. Moreover, it offered the possibility of adjunctive immunocytochemistry on the same sample.

  4. Locally smeared operator product expansions in scalar field theory

    DOE PAGES

    Monahan, Christopher; Orginos, Kostas

    2015-04-01

    We propose a new locally smeared operator product expansion to decompose non-local operators in terms of a basis of smeared operators. The smeared operator product expansion formally connects nonperturbative matrix elements determined numerically using lattice field theory to matrix elements of non-local operators in the continuum. These nonperturbative matrix elements do not suffer from power-divergent mixing on the lattice, which significantly complicates calculations of quantities such as the moments of parton distribution functions, provided the smearing scale is kept fixed in the continuum limit. The presence of this smearing scale complicates the connection to the Wilson coefficients of the standardmore » operator product expansion and requires the construction of a suitable formalism. We demonstrate the feasibility of our approach with examples in real scalar field theory.« less

  5. The Role of MGIT 960 Culture Medium in Resolving the Diagnostic Dilemma for Genital Tuberculosis Patients Presenting with Infertility.

    PubMed

    Jindal, Nidhi; Gainder, Shalini; Dhaliwal, Lakhbir Kaur; Sethi, Sunil

    2018-04-01

    The purpose of this study was to assess the utility of Mycobacteria Growth Indicator Tube (MGIT) 960 culture medium for the diagnosis of genital tuberculosis (GTB) in women presenting with infertility. The premenstrual endometrial biopsy samples in 300 women presenting with primary and secondary infertility were subjected to AFB smear method, histopathological examination and culture on LJ and MGIT 960 media. Detection rates were compared for diagnostic modalities and their combinations. In total, 30 cases were positive for genital tuberculosis by either of the four tests employed. The detection rates for AFB smear, MGIT culture, LJ culture and HPE were 50, 46.7, 3.3 and 33.3%, respectively. A combination of smear examination for AFB, MGIT 960 culture and histopathological examination was able to detect all the positive cases. A combination of MGIT and LJ media provided no added advantage over MGIT alone since the only case where LJ culture was positive had been detected by positive MGIT culture. In as many as five positive cases (16.7%), only MGIT culture was positive. The addition of MGIT 960 culture medium to routine battery of investigations in infertility patients significantly improves the diagnosis.

  6. [Wing 1 radiation survey and contamination report]. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olsen, K.

    We have completed the 5480.11 survey for Wing 1. All area(s)/item(s) requested by the 5480.11 committee have been thoroughly surveyed and documented. Decontamination/disposal of contaminated items has been accomplished. The wing 1 survey was started on 8/13/90 and completed 9/18/90. However, the follow-up surveys were not completed until 2/18/91. We received the final set of smear samples for wing 1 on 1/13/91. A total of 5,495 smears were taken from wing 1 and total of 465 smears were taken during the follow-up surveys. There were a total 122 items found to have fixed contamination and 4 items with smearable contaminationmore » in excess of the limits specified in DOE ORDER 5480.11 (AR 3-7). The following area(s)/item(s) were not included in the 5480.11 survey: Hallways, Access panels, Men`s and women`s change rooms, Janitor closets, Wall lockers and item(s) stored in wing 1 hallways and room 1116. If our contract is renewed, we will include those areas in our survey according to your request of April 15, 1991.« less

  7. Recent advances in tuberculosis diagnostics in resource-limited settings.

    PubMed

    Seki, Mitsuko; Kim, Chang-Ki; Hayakawa, Satoshi; Mitarai, Satoshi

    2018-04-19

    Smear-negative and drug-resistant cases of tuberculosis (TB) disease necessitate the development of new diagnostic methods, especially in resource-limited settings. To improve the current TB situations, sensitive and specific TB point-of-care tests (POCTs) should be developed. This review addresses the current status of TB, novel diagnostic methodologies for TB, and the impact of those new diagnostics on TB control in such situations. Moreover, the perspective of TB management based on laboratory examinations is described. Smear microscopy with sputum samples is the only laboratory examination available in many resource-limited settings and is still used globally. Several nucleic acid amplification tests (NATs) have been developed. The World Health Organization (WHO) endorsed novel diagnostics based on NATs and updated their definition of a bacteriologically confirmed case requiring the biological specimen to be positive by smear microscopy, culture, or the WHO-recommended rapid diagnostic protocols. The use of new diagnostics increased the number of bacteriologically confirmed TB cases. Novel diagnostics are now available, but their sensitivity is still lower than that of conventional liquid culture method. To address the increasing incidence of TB, more resources including novel diagnostics as POCTs with higher sensitivity must be allocated to healthcare systems.

  8. Scanning electron microscopy (SEM) evaluation of sealing ability of MTA and EndoSequence as root-end filling materials with chitosan and carboxymethyl chitosan (CMC) as retrograde smear layer removing agents.

    PubMed

    Nagesh, Bolla; Jeevani, Eppala; Sujana, Varri; Damaraju, Bharagavi; Sreeha, Kaluvakolanu; Ramesh, Penumaka

    2016-01-01

    The purpose of this study was to evaluate the sealing ability of mineral trioxide aggregate (MTA) and EndoSequence with chitosan and carboxymethyl chitosan (CMC) as retrograde smear layer removing agents using scanning electron microscopy (SEM). Forty human single rooted teeth were taken. Crowns were decoronated and canals were obturated. Apically roots were resected and retrograde cavities were done. Based on the type of retrograde material placed and the type of smear layer removal agent used for retrograde cavities, they were divided into four groups (N = 10): Group I chitosan with EndoSequence, group II chitosan with MTA, group III CMC with EndoSequence, and Group IV CMC with MTA. All the samples were longitudinally sectioned, and the SEM analysis was done for marginal adaptation. Kruskal-Wallis and Mann-Witney analysis tests. SEM images showed the presence of less gaps in group III, i.e., CMC with EndoSequence when compared to other groups with statistically significant difference. Within the limited scope of this study, it was concluded that EndoSequence as retrograde material showed better marginal sealing ability.

  9. A simple modification of the Baermann method for diagnosis of strongyloidiasis.

    PubMed

    Hernández-Chavarría, F; Avendaño, L

    2001-08-01

    The diagnosis of Strongyloides stercoralis infections is routinely made by microscopic observation of larvae in stool samples, a low sensitivity method, or by other, most effective methods, such as the Baermann or agar culture plate methods. We propose in this paper a practical modification of Baermann method. One hundred and six stool samples from alcoholic patients were analyzed using the direct smear test, agar culture plate method, the standard Baermann method, and its proposed modification. For this modification the funnel used in the original version of the method is substituted by a test tube with a rubber stopper, perforated to allow insertion of a pipette tip. The tube with a fecal suspension is inverted over another tube containing 6 ml of saline solution and incubated at 37 degrees C for at least 2 h. The saline solution from the second tube is centrifuged and the pellet is observed microscopically. Larva of S. stercoralis were detected in six samples (5.7%) by the two versions of the Baermann method. Five samples were positive using the agar culture plate method, and only in two samples the larva were observed using direct microscopic observation of fecal smears. Cysts of Endolimax nana and Entamoeba histolytica/dyspar were also detected in the modification of Baermann method. Data obtained by the modified Baermann method suggest that this methodology may helps concentrate larvae of S. stercoralis as efficiently as the original method.

  10. Performance evaluation of the Abbott CELL-DYN Ruby and the Sysmex XT-2000i haematology analysers.

    PubMed

    Leers, M P G; Goertz, H; Feller, A; Hoffmann, J J M L

    2011-02-01

    Two mid-range haematology analysers (Abbott CELL-DYN Ruby and Sysmex XT-2000i) were evaluated to determine their analytical performance and workflow efficiency in the haematology laboratory. In total 418 samples were processed for determining equivalence of complete blood count (CBC) measurements, and 100 for reticulocyte comparison. Blood smears served for assessing the agreement of the differential counts. Inter-instrument agreement for most parameters was good although small numbers of discrepancies were observed. Systematic biases were found for mean cell volume, reticulocytes, platelets and mean platelet volume. CELL-DYN Ruby WBC differentials were obtained with all samples while the XT-2000i suppressed differentials partially or completely in 13 samples (3.1%). WBC subpopulation counts were otherwise in good agreement with no major outliers. Following first-pass CBC/differential analysis, 88 (21%) of XT-2000i samples required further analyser processing compared to 18 (4.3%) for the CELL-DYN Ruby. Smear referrals for suspected WBC/nucleated red blood cells and platelet abnormalities were indicated for 106 (25.4%) and 95 (22.7%) of the XT-2000i and CELL-DYN Ruby samples respectively. Flagging efficiencies for both analysers were found to be similar. The Sysmex XT-2000i and Abbott CELL-DYN Ruby analysers have broadly comparable analytical performance, but the CELL-DYN Ruby showed superior first-pass efficiency. © 2010 Blackwell Publishing Ltd.

  11. Analysis of Leading Edge and Trailing Edge Cover Glass Samples Before and After Treatment with Advanced Satellite Contamination Removal Techniques

    DTIC Science & Technology

    1993-04-01

    surface analysis, 40 contamination control, ANCC ( Aerogel Mesh Contamination Collector) iPRICECODE 17. SECURITY CLASSIFICATION 1 & SECURITY CLASSIFICATION...operational parameter space (temperature, vibration, radiation, vacuum and micrometorite environments). One embodiment of this device, the Aerogel Mesh...Lippey and Dan Demeo of Hughes Aircraft Corporation for their kind hospitality and research collaboration on the contamination removal phase of this work

  12. Relationship Between Pelvic Organ Prolapse and Non-Human Papillomavirus Pap Smear Abnormalities.

    PubMed

    Menhaji, Kimia; Harvie, Heidi S; Cheston, Emily; Levin, Pamela J; Arya, Lily A; Andy, Uduak U

    2017-07-13

    The aim of this study was to determine the association between pelvic organ prolapse (POP) and non-human papillomavirus (HPV) Papanicolaou (Pap) smear abnormalities. This was a retrospective cohort study of women aged 40 to 70 years who presented for consultation at our institution between 2010 and 2015 and had results of a Pap smear and HPV test available within 5 years of their visit. We extracted demographic information, medical and social history, Pap smear, and HPV results from the electronic medical record. Associations between the presence of POP and non-HPV Pap smear abnormalities were estimated using univariable and multivariable analyses. We reviewed 1590 charts and excluded 980 women, leaving 610 women in the study: 183 with POP and 427 without POP. Women with POP were significantly older (58.2 ± 7.2 vs 55.6 ± 6.6, P < 0.01) and more likely to have a remote (>10 year) history of abnormal Pap smear (24.0% vs 14.8%, P < 0.01). The rate of non-HPV-associated abnormal Pap smears was higher in the POP group than in the non-POP group (12/183 [6.6%] vs 12/427 [2.8%], P = 0.029). In the POP group, the rate of non-HPV Pap smear abnormality was significantly associated with increasing prolapse stage (stage 1: 0/16 [0%], stage 2: 5/77 [6.5%], stage 3: 3/73 [4.1%], stage 4: 4/17 [23.5%]; P = 0.02). After controlling for age and remote history of abnormal Pap smear, the odds ratio for non-HPV Pap smear abnormalities in the POP group remained significant (2.49; 95% confidence interval, 1.08-5.79). Human papillomavirus-negative Pap smear abnormalities may be related to POP. Our findings have important implications for surgeons seeking to leave the cervix in situ in women with POP.

  13. Progressive Failure of a Unidirectional Fiber-Reinforced Composite Using the Method of Cells: Discretization Objective Computational Results

    NASA Technical Reports Server (NTRS)

    Pineda, Evan J.; Bednarcyk, Brett A.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    The smeared crack band theory is implemented within the generalized method of cells and high-fidelity generalized method of cells micromechanics models to capture progressive failure within the constituents of a composite material while retaining objectivity with respect to the size of the discretization elements used in the model. An repeating unit cell containing 13 randomly arranged fibers is modeled and subjected to a combination of transverse tension/compression and transverse shear loading. The implementation is verified against experimental data (where available), and an equivalent finite element model utilizing the same implementation of the crack band theory. To evaluate the performance of the crack band theory within a repeating unit cell that is more amenable to a multiscale implementation, a single fiber is modeled with generalized method of cells and high-fidelity generalized method of cells using a relatively coarse subcell mesh which is subjected to the same loading scenarios as the multiple fiber repeating unit cell. The generalized method of cells and high-fidelity generalized method of cells models are validated against a very refined finite element model.

  14. Verification Test of the SURF and SURFplus Models in xRage: Part II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menikoff, Ralph

    2016-06-20

    The previous study used an underdriven detonation wave (steady ZND reaction zone profile followed by a scale invariant rarefaction wave) for PBX 9502 as a validation test of the implementation of the SURF and SURFplus models in the xRage code. Even with a fairly fine uniform mesh (12,800 cells for 100mm) the detonation wave profile had limited resolution due to the thin reaction zone width (0.18mm) for the fast SURF burn rate. Here we study the effect of finer resolution by comparing results of simulations with cell sizes of 8, 2 and 1 μm, which corresponds to 25, 100 andmore » 200 points within the reaction zone. With finer resolution the lead shock pressure is closer to the von Neumann spike pressure, and there is less noise in the rarefaction wave due to fluctuations within the reaction zone. As a result the average error decreases. The pointwise error is still dominated by the smearing the pressure kink in the vicinity of the sonic point which occurs at the end of the reaction zone.« less

  15. Flagging threshold optimization for manual blood smear review in primary care laboratory.

    PubMed

    Bihl, Pierre-Adrien

    2018-04-01

    Manual blood smear review is required when an anomaly detected by the automated hematologic analyzer triggers a flag. Our will through this study is to optimize these flagging thresholds for manual slide review in order to limit workload, while insuring clinical care through no extra false-negative. Flagging causes of 4,373 samples were investigated by manual slide review, after having been run on ADVIA 2120i. A set of 6 user-adjustments is proposed. By implementing all recommendations that we made, false-positive rate falls from 81.8% to 58.6%, while PPV increases from 18.2% to 23.7%. Hence, use of such optimized thresholds enables us to maximize efficiency without altering clinical care, but each laboratory should establish its own criteria to take into consideration local distinctive features.

  16. Ancient pathogens in museal dry bone specimens: analysis of paleocytology and aDNA.

    PubMed

    Gaul, Johanna Sophia; Winter, Eduard; Grossschmidt, Karl

    2015-04-01

    Bone samples investigated in this study derive from the pathologic-anatomical collection of the Natural History Museum of Vienna. In order to explore the survival of treponemes and treponemal ancient DNA in museal dry bone specimens, we analyzed three individuals known to have been infected with Treponema pallidum pallidum. No reproducible evidence of surviving pathogen's ancient DNA (aDNA) was obtained, despite the highly sensitive extraction and amplification techniques (TPP15 and arp). Additionally, decalcification fluid of bone sections was smear stained with May-Gruenwald-Giemsa. The slides were examined using direct light microscope and dark field illumination. Remnants of spirochetal structures were detectable in every smear. Our results demonstrate that aDNA is unlikely to survive, but spirochetal remains are stainable and thus detectable.

  17. Distribution of polycyclic aromatic hydrocarbons in lime spray dryer ash

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ping Sun; Panuwat Taerakul; Linda K. Weavers

    Four lime spray dryer (LSD) ash samples were collected from a spreader stoker boiler and measured for their concentrations of 16 U.S. EPA specified polycyclic aromatic hydrocarbons (PAHs). Results showed that the total measured PAH concentration correlated with the organic carbon content of the LSD ash. Each LSD ash sample was then separated using a 140 mesh sieve into two fractions: a carbon-enriched fraction ({gt}140 mesh) and a lime-enriched fraction ({lt}140 mesh). Unburned carbon was further separated from the carbon-enriched fraction with a lithiumheteropolytungstate (LST) solution. PAH measurements on these different fractions showed that unburned carbon had the highest PAHmore » concentrations followed by the carbon-enriched fraction, indicating that PAHs were primarily associated with the carbonaceous material in LSD ash. However, detectable levels of PAHs were also found in the lime-enriched fraction, suggesting that the fine spray of slaked lime may sorb PAH compounds from the flue gas in the LSD process. 37 refs., 5 figs., 4 tabs.« less

  18. Kinetic solvers with adaptive mesh in phase space

    NASA Astrophysics Data System (ADS)

    Arslanbekov, Robert R.; Kolobov, Vladimir I.; Frolova, Anna A.

    2013-12-01

    An adaptive mesh in phase space (AMPS) methodology has been developed for solving multidimensional kinetic equations by the discrete velocity method. A Cartesian mesh for both configuration (r) and velocity (v) spaces is produced using a “tree of trees” (ToT) data structure. The r mesh is automatically generated around embedded boundaries, and is dynamically adapted to local solution properties. The v mesh is created on-the-fly in each r cell. Mappings between neighboring v-space trees is implemented for the advection operator in r space. We have developed algorithms for solving the full Boltzmann and linear Boltzmann equations with AMPS. Several recent innovations were used to calculate the discrete Boltzmann collision integral with dynamically adaptive v mesh: the importance sampling, multipoint projection, and variance reduction methods. We have developed an efficient algorithm for calculating the linear Boltzmann collision integral for elastic and inelastic collisions of hot light particles in a Lorentz gas. Our AMPS technique has been demonstrated for simulations of hypersonic rarefied gas flows, ion and electron kinetics in weakly ionized plasma, radiation and light-particle transport through thin films, and electron streaming in semiconductors. We have shown that AMPS allows minimizing the number of cells in phase space to reduce the computational cost and memory usage for solving challenging kinetic problems.

  19. Kinetic solvers with adaptive mesh in phase space.

    PubMed

    Arslanbekov, Robert R; Kolobov, Vladimir I; Frolova, Anna A

    2013-12-01

    An adaptive mesh in phase space (AMPS) methodology has been developed for solving multidimensional kinetic equations by the discrete velocity method. A Cartesian mesh for both configuration (r) and velocity (v) spaces is produced using a "tree of trees" (ToT) data structure. The r mesh is automatically generated around embedded boundaries, and is dynamically adapted to local solution properties. The v mesh is created on-the-fly in each r cell. Mappings between neighboring v-space trees is implemented for the advection operator in r space. We have developed algorithms for solving the full Boltzmann and linear Boltzmann equations with AMPS. Several recent innovations were used to calculate the discrete Boltzmann collision integral with dynamically adaptive v mesh: the importance sampling, multipoint projection, and variance reduction methods. We have developed an efficient algorithm for calculating the linear Boltzmann collision integral for elastic and inelastic collisions of hot light particles in a Lorentz gas. Our AMPS technique has been demonstrated for simulations of hypersonic rarefied gas flows, ion and electron kinetics in weakly ionized plasma, radiation and light-particle transport through thin films, and electron streaming in semiconductors. We have shown that AMPS allows minimizing the number of cells in phase space to reduce the computational cost and memory usage for solving challenging kinetic problems.

  20. Intermediate-grade squamous intraepithelial lesion may be a valid diagnostic/interpretive category.

    PubMed

    Ravinsky, Esther; Baker, Patricia

    2009-02-01

    We undertook this study to assess the characteristics of smears with features intermediate between high-grade squamous intraepithelial lesion (HSIL) and low-grade squamous intraepithelial lesion (ISIL). We also wanted to determine how these smears correlate with high risk biopsy diagnosis and to compare this with the biopsy correlation of LSIL and HSIL. Seventy-four squamous intraepithelial lesion (SIL) smears were identified as intermediate-grade SIL smears taken at colposcopy in a 1 year period. They were correlated with concurrent colposcopically guided biopsies. Thirty-five percent of cases with intermediate-grade SIL smears had a biopsy diagnosis of moderate dysplasia or higher as compared with 12% for LSIL 74% for HSIL. This confirmed our hypothesis that intermediate-grade SIL smears have a rate of biopsy diagnosis of moderate dysplasia or higher intermediate to that of LSIL and HSIL.

  1. Conformational Smear Characterization and Binning of Single-Molecule Conductance Measurements for Enhanced Molecular Recognition.

    PubMed

    Korshoj, Lee E; Afsari, Sepideh; Chatterjee, Anushree; Nagpal, Prashant

    2017-11-01

    Electronic conduction or charge transport through single molecules depends primarily on molecular structure and anchoring groups and forms the basis for a wide range of studies from molecular electronics to DNA sequencing. Several high-throughput nanoelectronic methods such as mechanical break junctions, nanopores, conductive atomic force microscopy, scanning tunneling break junctions, and static nanoscale electrodes are often used for measuring single-molecule conductance. In these measurements, "smearing" due to conformational changes and other entropic factors leads to large variances in the observed molecular conductance, especially in individual measurements. Here, we show a method for characterizing smear in single-molecule conductance measurements and demonstrate how binning measurements according to smear can significantly enhance the use of individual conductance measurements for molecular recognition. Using quantum point contact measurements on single nucleotides within DNA macromolecules, we demonstrate that the distance over which molecular junctions are maintained is a measure of smear, and the resulting variance in unbiased single measurements depends on this smear parameter. Our ability to identify individual DNA nucleotides at 20× coverage increases from 81.3% accuracy without smear analysis to 93.9% with smear characterization and binning (SCRIB). Furthermore, merely 7 conductance measurements (7× coverage) are needed to achieve 97.8% accuracy for DNA nucleotide recognition when only low molecular smear measurements are used, which represents a significant improvement over contemporary sequencing methods. These results have important implications in a broad range of molecular electronics applications from designing robust molecular switches to nanoelectronic DNA sequencing.

  2. Diagnostic utility of melanin production by fungi: study on tissue sections and culture smears with Masson-Fontana stain.

    PubMed

    Sundaram, Challa; Shantveer, G Uppin; Umabala, Pamidi; Lakshmi, Vemu

    2014-01-01

    Dematiaceous fungi appear brown in tissue section due to melanin in their cell walls. When the brown color is not seen on routine H and E and culture is not available, differentiation of dematiaceous fungi from other fungi is difficult on morphology alone. To study if melanin production by dematiaceous fungi can help differentiate them from other types of fungi. Fifty tissue sections of various fungal infections and 13 smears from cultures of different species of fungi were stained with Masson Fontana stain to assess melanin production. The tissue sections included biopsies from 26 culture-proven fungi and 24 biopsies of filamentous fungi diagnosed on morphology alone with no culture confirmation. All culture-proven dematiaceous fungi and Zygomycetes showed strong positivity in sections and culture smears. Aspergillus sp showed variable positivity and intensity. Cryptococcus neoformans showed strong positivity in tissue sections and culture smears. Tissue sections of septate filamentous fungi (9/15), Zygomycetes (4/5), and fungi with both hyphal and yeast morphology (4/4) showed positivity for melanin. The septate filamentous fungi negative for melanin were from biopsy samples of fungal sinusitis including both allergic and invasive fungal sinusitis and colonizing fungal balls. Melanin is produced by both dematiaceous and non-dematiaceous fungi. Masson-Fontana stain cannot reliably differentiate dematiaceous fungi from other filamentous fungi like Aspergillus sp; however, absence of melanin in the hyphae may be used to rule out dematiaceous fungi from other filamentous fungi. In the differential diagnosis of yeast fungi, Cryptococcus sp can be differentiated from Candida sp by Masson-Fontana stain in tissue sections.

  3. Awareness and uptake of colorectal, breast, cervical and prostate cancer screening tests in Spain.

    PubMed

    Carrasco-Garrido, Pilar; Hernandez-Barrera, Valentın; Lopez de Andres, Ana; Jimenez-Trujillo, Isabel; Gallardo Pino, Carmen; Jimenez-Garcıa, Rodrigo

    2014-04-01

    We aim to describe levels of awareness and uptake of colorectal, breast, cervical and prostate cancer screening tests and to analyze the association to socio-demographic and health-related variables. Population-based cross-sectional study conducted using a home-based personal interview survey on a nationwide representative sample (n = 7938) of population aged ≥18 years (Oncobarometro Survey). Awareness was assessed by asking participants: Now I am going to mention several medical tests for cancer detection, please tell me if you already know about them or if this is the first time you have heard of them? The tests mentioned were faecal occult blood test (FOBT), mammography, Pap smear and prostate-specific antigen (PSA). Cancer screening uptake was assessed by asking participants whether they had received tests within the previous 2 years. Awareness rates of 38.55% for FOBT, 95.03% for mammography, 70.84% for Pap smears and 54.72% for PSA were found. Uptake mammography was 74.46%, Pap smears 65.57%, PSA 35.19% and FOBT 9.40%. Factors such as immigration status, lower educational level or income and not suffering from chronic conditions are negative predictors for uptake. Awareness and uptake results showed acceptable figures for mammography, moderate for Pap smears and unacceptably low for FOBT. Inequalities exist in uptake of cancer screening. It is necessary to develop public health educational programmes, especially for the vulnerable populations, aiming to inform and motivate them to use screening services on a regular basis. Our data suggest that although PSA is not recommended, this opportunistic screening is frequently used in Spain.

  4. Using Natural Language Processing to Extract Abnormal Results From Cancer Screening Reports.

    PubMed

    Moore, Carlton R; Farrag, Ashraf; Ashkin, Evan

    2017-09-01

    Numerous studies show that follow-up of abnormal cancer screening results, such as mammography and Papanicolaou (Pap) smears, is frequently not performed in a timely manner. A contributing factor is that abnormal results may go unrecognized because they are buried in free-text documents in electronic medical records (EMRs), and, as a result, patients are lost to follow-up. By identifying abnormal results from free-text reports in EMRs and generating alerts to clinicians, natural language processing (NLP) technology has the potential for improving patient care. The goal of the current study was to evaluate the performance of NLP software for extracting abnormal results from free-text mammography and Pap smear reports stored in an EMR. A sample of 421 and 500 free-text mammography and Pap reports, respectively, were manually reviewed by a physician, and the results were categorized for each report. We tested the performance of NLP to extract results from the reports. The 2 assessments (criterion standard versus NLP) were compared to determine the precision, recall, and accuracy of NLP. When NLP was compared with manual review for mammography reports, the results were as follows: precision, 98% (96%-99%); recall, 100% (98%-100%); and accuracy, 98% (96%-99%). For Pap smear reports, the precision, recall, and accuracy of NLP were all 100%. Our study developed NLP models that accurately extract abnormal results from mammography and Pap smear reports. Plans include using NLP technology to generate real-time alerts and reminders for providers to facilitate timely follow-up of abnormal results.

  5. Prevalence of Anaplasma phagocytophilum infection in feral cats in Massachusetts.

    PubMed

    Galemore, Erin R; Labato, Mary A; O'Neil, Elizabeth

    2018-01-01

    The primary objective of this study was to determine the prevalence of Anaplasma phagocytophilum infection and exposure in adult feral cats in Massachusetts, an endemic area for A phagocytophilum and its tick vector Ixodes scapularis . The secondary objective was to determine if there were correlations between A phagocytophilum infection and the presence of anemia and thrombocytopenia. Blood samples were collected between June and December 2015 from 175 apparently healthy adult feral cats that were presented to trap and release spay/neuter centers in Massachusetts. Complete blood count, blood smear evaluation, SNAP 4Dx Plus test (IDEXX) and A phagocytophilum PCR were performed on all samples to document acute infection (PCR-positive and/or inclusions observed on blood smear) and exposure to A phagocytophilum (SNAP 4Dx Plus-positive for A phagocytophilum antibodies). The prevalence of exposure to A phagocytophilum in feral cats in Massachusetts was 9.7%, whereas the prevalence of acute infection was 6.9%. All blood smears were negative for Anaplasma species inclusions; therefore, acute infection was defined as testing positive on PCR analysis. No statistically significant correlations were identified for cats that were positive for A phagocytophilum on PCR analysis or SNAP 4Dx Plus test and the presence of anemia or thrombocytopenia. The prevalence of A phagocytophilum exposure in feral cats approaches 10% and is higher than the previously reported national average prevalence of 4.3% in the USA. A phagocytophilum infection may be an emerging infectious disease in cats. Further research is needed to determine the prevalence of clinical illness associated with A phagocytophilum infection in cats living in endemic areas.

  6. Falciparum Malaria Outbreak in Sabah Linked to an Immigrant Rubber Tapper.

    PubMed

    Jeffree, Saffree Mohammad; Ahmed, Kamruddin; Safian, Nazarudin; Hassan, Rohaizat; Mihat, Omar; Lukman, Khamisah Awang; Shamsudin, Shamsul Bahari; Kamaludin, Fadzilah

    2018-01-01

    Sabah is a Malaysian state situated in the northern part of Borneo, and it is endemic for malaria. The incidence of malaria is the lowest (0.05/1,000 population) in Penampang districts of Sabah. In June 26, 2012, two Plasmodium falciparum malaria cases were notified to public health department from a village in Penampang. Immediate investigation was initiated to identify the risk factors and to institute control measures. We performed active case finding by asking household members of all houses in the village regarding malaria symptoms and by examining blood smears. Environmental investigation was performed by collecting samples to detect mosquito breeding sites and to identify malaria transmitting vector mosquitoes. A case-control study with a ratio of 1:4 (11 cases and 44 controls) was conducted using self-administered questionnaire. The microscopic examination of blood smear for malarial parasite and entomology sampling was carried out. The malarial attack rate was 2.3%, 6/11 smears have gametocyte, and the case fatality rate was 9.1%. One case was a migrant rubber tapper from Indonesia which happened to be the first case with gametocyte positive. Overall, the incidence of malaria was higher (6/11) among rubber tappers. The odds of cases for those living nearby stagnant water were 7.3 [95% confidence interval: 1.2-43.5] times higher. In conclusion, an outbreak of P. falciparum malaria was introduced into a malaria-free village by a migrant rubber tapper, by whom the imported parasite was introduced to the community via vector Anopheles balabacensis . Living near stagnant water bodies was the risk factor in this outbreak.

  7. Use of Occult Blood Detection Cards for Real-Time PCR-Based Diagnosis of Schistosoma Mansoni Infection

    PubMed Central

    Schunk, Mirjam; Kebede Mekonnen, Seleshi; Wondafrash, Beyene; Mengele, Carolin; Fleischmann, Erna; Herbinger, Karl-Heinz; Verweij, Jaco J.; Geldmacher, Christof; Bretzel, Gisela; Löscher, Thomas; Zeynudin, Ahmed

    2015-01-01

    Background In Schistosoma mansoni infection, diagnosis and control after treatment mainly rely on parasitological stool investigations which are laborious and have limited sensitivity. PCR methods have shown equal or superior sensitivity but preservation and storage methods limit their use in the field. Therefore, the use of occult blood detection cards (fecal cards) for easy sampling and storage of fecal samples for further PCR testing was evaluated in a pilot study. Methodology Stool specimens were collected in a highly endemic area for S. mansoni in Ethiopia and submitted in an investigator-blinded fashion to microscopic examination by Kato-Katz thick smear as well as to real-time PCR using either fresh frozen stool samples or stool smears on fecal cards which have been stored at ambient temperature for up to ten months. Principal Findings Out of 55 stool samples, 35 were positive by microscopy, 33 and 32 were positive by PCR of frozen samples and of fecal card samples, respectively. When microscopy was used as diagnostic “gold standard”, the sensitivity of PCR on fresh stool was 94.3% (95%-CI: 86.6; 100) and on fecal cards 91.4% (95%-CI: 82.2; 100). Conclusions The use of fecal cards proved to be a simple and useful method for stool collection and prolonged storage prior to PCR based diagnosis of S. mansoni infection. This technique may be a valuable approach for large scale surveillance and post treatment assessments PMID:26360049

  8. Use of Occult Blood Detection Cards for Real-Time PCR-Based Diagnosis of Schistosoma Mansoni Infection.

    PubMed

    Schunk, Mirjam; Kebede Mekonnen, Seleshi; Wondafrash, Beyene; Mengele, Carolin; Fleischmann, Erna; Herbinger, Karl-Heinz; Verweij, Jaco J; Geldmacher, Christof; Bretzel, Gisela; Löscher, Thomas; Zeynudin, Ahmed

    2015-01-01

    In Schistosoma mansoni infection, diagnosis and control after treatment mainly rely on parasitological stool investigations which are laborious and have limited sensitivity. PCR methods have shown equal or superior sensitivity but preservation and storage methods limit their use in the field. Therefore, the use of occult blood detection cards (fecal cards) for easy sampling and storage of fecal samples for further PCR testing was evaluated in a pilot study. Stool specimens were collected in a highly endemic area for S. mansoni in Ethiopia and submitted in an investigator-blinded fashion to microscopic examination by Kato-Katz thick smear as well as to real-time PCR using either fresh frozen stool samples or stool smears on fecal cards which have been stored at ambient temperature for up to ten months. Out of 55 stool samples, 35 were positive by microscopy, 33 and 32 were positive by PCR of frozen samples and of fecal card samples, respectively. When microscopy was used as diagnostic "gold standard", the sensitivity of PCR on fresh stool was 94.3% (95%-CI: 86.6; 100) and on fecal cards 91.4% (95%-CI: 82.2; 100). The use of fecal cards proved to be a simple and useful method for stool collection and prolonged storage prior to PCR based diagnosis of S. mansoni infection. This technique may be a valuable approach for large scale surveillance and post treatment assessments.

  9. Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair

    PubMed Central

    Melman, L.; Jenkins, E. D.; Hamilton, N. A.; Bender, L. C.; Brodt, M. D.; Deeken, C. R.; Greco, S. C.; Frisella, M. M.

    2013-01-01

    Purpose To evaluate the biocompatibility of heavyweight polypropylene (HWPP), lightweight polypropylene (LWPP), and monofilament knit polytetrafluoroethylene (mkPTFE) mesh by comparing biomechanics and histologic response at 1, 3, and 5 months in a porcine model of incisional hernia repair. Methods Bilateral full-thickness abdominal wall defects measuring 4 cm in length were created in 27 Yucatan minipigs. Twenty-one days after hernia creation, animals underwent bilateral preperitoneal ventral hernia repair with 8 × 10 cm pieces of mesh. Repairs were randomized to Bard®Mesh (HWPP, Bard/Davol, http://www.davol.com), ULTRAPRO® (LWPP, Ethicon, http://www.ethicon.com), and GORE®INFINIT Mesh (mkPTFE, Gore & Associates, http://www.gore.com). Nine animals were sacrificed at each timepoint (1, 3, and 5 months). At harvest, a 3 × 4 cm sample of mesh and incorporated tissue was taken from the center of the implant site and subjected to uniaxial tensile testing at a rate of 0.42 mm/s. The maximum force (N) and tensile strength (N/cm) were measured with a tensiometer, and stiffness (N/mm) was calculated from the slope of the force-versus-displacement curve. Adjacent sections of tissue were stained with hematoxylin and eosin (H&E) and analyzed for inflammation, fibrosis, and tissue ingrowth. Data are reported as mean ± SEM. Statistical significance (P < 0.05) was determined using a two-way ANOVA and Bonferroni post-test. Results No significant difference in maximum force was detected between meshes at any of the time points (P > 0.05 for all comparisons). However, for each mesh type, the maximum strength at 5 months was significantly lower than that at 1 month (P < 0.05). No significant difference in stiffness was detected between the mesh types or between timepoints (P > 0.05 for all comparisons). No significant differences with regard to inflammation, fibrosis, or tissue ingrowth were detected between mesh types at any time point (P > 0.09 for all comparisons). However, over time, inflammation decreased significantly for all mesh types (P < 0.001) and tissue ingrowth reached a slight peak between 1 and 3 months (P = 0.001) but did not significantly change thereafter (P > 0.09). Conclusions The maximum tensile strength of mesh in the abdominal wall decreased over time for HWPP, LWPP, and mkPTFE mesh materials alike. This trend may actually reflect inability to adequately grip specimens at later time points rather than any mesh-specific trend. Histologically, inflammation decreased with time (P = 0.000), and tissue ingrowth increased (P = 0.019) for all meshes. No specific trends were observed between the polypropylene meshes and the monofilament knit PTFE, suggesting that this novel construction may be a suitable alternative to existing polypropylene meshes. PMID:21279663

  10. Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair.

    PubMed

    Melman, L; Jenkins, E D; Hamilton, N A; Bender, L C; Brodt, M D; Deeken, C R; Greco, S C; Frisella, M M; Matthews, B D

    2011-08-01

    To evaluate the biocompatibility of heavyweight polypropylene (HWPP), lightweight polypropylene (LWPP), and monofilament knit polytetrafluoroethylene (mkPTFE) mesh by comparing biomechanics and histologic response at 1, 3, and 5 months in a porcine model of incisional hernia repair. Bilateral full-thickness abdominal wall defects measuring 4 cm in length were created in 27 Yucatan minipigs. Twenty-one days after hernia creation, animals underwent bilateral preperitoneal ventral hernia repair with 8 × 10 cm pieces of mesh. Repairs were randomized to Bard(®)Mesh (HWPP, Bard/Davol, http://www.davol.com), ULTRAPRO(®) (LWPP, Ethicon, http://www.ethicon.com), and GORE(®)INFINIT Mesh (mkPTFE, Gore & Associates, http://www.gore.com). Nine animals were sacrificed at each timepoint (1, 3, and 5 months). At harvest, a 3 × 4 cm sample of mesh and incorporated tissue was taken from the center of the implant site and subjected to uniaxial tensile testing at a rate of 0.42 mm/s. The maximum force (N) and tensile strength (N/cm) were measured with a tensiometer, and stiffness (N/mm) was calculated from the slope of the force-versus-displacement curve. Adjacent sections of tissue were stained with hematoxylin and eosin (H&E) and analyzed for inflammation, fibrosis, and tissue ingrowth. Data are reported as mean ± SEM. Statistical significance (P < 0.05) was determined using a two-way ANOVA and Bonferroni post-test. No significant difference in maximum force was detected between meshes at any of the time points (P > 0.05 for all comparisons). However, for each mesh type, the maximum strength at 5 months was significantly lower than that at 1 month (P < 0.05). No significant difference in stiffness was detected between the mesh types or between timepoints (P > 0.05 for all comparisons). No significant differences with regard to inflammation, fibrosis, or tissue ingrowth were detected between mesh types at any time point (P > 0.09 for all comparisons). However, over time, inflammation decreased significantly for all mesh types (P < 0.001) and tissue ingrowth reached a slight peak between 1 and 3 months (P = 0.001) but did not significantly change thereafter (P > 0.09). The maximum tensile strength of mesh in the abdominal wall decreased over time for HWPP, LWPP, and mkPTFE mesh materials alike. This trend may actually reflect inability to adequately grip specimens at later time points rather than any mesh-specific trend. Histologically, inflammation decreased with time (P = 0.000), and tissue ingrowth increased (P = 0.019) for all meshes. No specific trends were observed between the polypropylene meshes and the monofilament knit PTFE, suggesting that this novel construction may be a suitable alternative to existing polypropylene meshes.

  11. Clinical value of whole-blood interferon-gamma assay in patients with suspected pulmonary tuberculosis and AFB smear- and polymerase chain reaction-negative bronchial aspirates.

    PubMed

    Lee, Jaehee; Lee, Shin Yup; Yoo, Seung Soo; Cha, Seung Ick; Won, Dong Il; Park, Jae Yong; Lee, Won-Kil; Kim, Chang Ho

    2012-07-01

    Combining a polymerase chain reaction (PCR) test with bronchoscopy is frequently performed to allow a rapid diagnosis of smear-negative pulmonary tuberculosis (PTB). However, limited data are available concerning clinical judgment in patients with suspected PTB and AFB smear- and PCR-negative bronchial aspirates (BA). The present study evaluated the usefulness of whole-blood QuantiFERON-TB Gold In-Tube (QFT) testing in these patients. Of 166 patients with suspected PTB who had undergone bronchoscopy because of smear-negative sputum or inadequate sputum production, 93 (56%) were diagnosed with culture-positive PTB. Seventy-four patients were either AFB smear- or PCR-positive. In the 75 patients whose BA AFB smear and PCR results were both negative, 19 were finally diagnosed with PTB by culture. The QFT test had a negative predictive value of 91% for PTB. The QFT test may be useful for excluding PTB in patients with suspected PTB whose BA AFB smear and PCR results are both negative. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Front-loaded smear microscopy for the diagnosis of pulmonary TB in Tripoli, Libya.

    PubMed

    Gammo, Mohamed; Lamaric, Widad; Hadida, Mukhtar; Abuazza, Aida; Askar, Nabil A; Yassin, Mohammed A; Cuevas, Luis E

    2013-02-01

    Diagnosis of pulmonary TB by conventional smear microscopy requires patient attendance on 2 consecutive days. We investigated whether collecting sputum on-the-spot for smear microscopy on the day the patient presented was as sensitive and specific for diagnosis as the conventional spot-morning-spot scheme. We enrolled 412 adults who presented between January 2009 and October 2010 at the National Centre for TB Control in Tripoli, Libya, with cough of >2 weeks' duration, into a cross-sectional survey collecting four sputum specimens: on-the-spot and Xspot on Day 1; morning and on-the-spot on Day 2. 97 (24%) of 401 culture results were culture positive. Spot-Xspot and spot-morning smear microscopy had, respectively, 65% and 66% sensitivity and 97% and 96% specificity (p > 0.5). Spot-Xspot-morning and Spot-morning-spot smear-microscopy had, respectively, 67% and 66% sensitivity and 96% and 96% specificity (p > 0.5). For the diagnosis of pulmonary TB, the sensitivity and specificity of front-loaded (same-day) smear microscopy is similar to that of the standard smear microscopy scheme.

  13. [Squamous intraepithlelial lesions in women's lupus].

    PubMed

    Mercado, Ulises

    2009-09-01

    previous studies have suggested an association between systemic lupus erythematosus (SLE), abnormal cervical smears and squamous intraepithelial lesions (SIL), but the underlying cause of this association is not well defined. To review Pap smear and biopsy results in SLE women compared with healthy controls and to identify traditional risk factors associated with abnormal smears. Retrospective cohort study. Sixty-two SLE patients and 1719 controls were included. Women with abnormal Pap smear results were referred to colposcopic biopsy histology. Information on traditional risk factors was obtained. Among SLE patients, activity score (Mex-SLEDAI) and immunosuppressive drugs exposure also were determined. Fourteen (22%) out of 62 patients had abnormal Pap smear results, compared with 120 (7%) out of 1719 controls. Thirteen (92%) out of 14 patients showed SIL by histological examination, compared with 27 (22%) out of 120 controls. Two SLE women had condylomata. There were no significant differences in the use of immunosuppressive agents among SLE patients with and without SIL. Abnormal Pap smears, SIL by biopsy and changes in the sexual behavioral were more common among SLE patients than in controls. The immunosuppressive drug exposure was not associated with abnormal Pap smears.

  14. Stool guaiac test

    MedlinePlus

    ... guaiac test; gFOBT; Guaiac smear test; Fecal occult blood test - guaiac smear; Stool occult blood test - guaiac smear ... This test detects blood in the digestive tract. It may be done if: You are being screened or tested for colon cancer You ...

  15. Blood Smear: MedlinePlus Lab Test Information

    MedlinePlus

    ... Test Information → Blood Smear URL of this page: https://medlineplus.gov/labtests/bloodsmear.html Blood Smear To ... May 26]; 353(5): 498–507. Available from: http://www.nejm.org/doi/full/10.1056/NEJMra043442 ...

  16. Optimization of FNAC findings as a preoperative diagnostic aid for odontogenic cysts.

    PubMed

    Jain, Garima; Shetty, Pushparaja

    2015-01-01

    Fine-needle aspiration cytology (FNAC) is not a definitive preoperative diagnostic procedure done for all cases of odontogenic cysts. This is because of the inconsistent results obtained with it. This study was done to optimize FNAC findings and help in preoperative characterization of odontogenic cysts. Cystic fluid was collected and centrifuged from 50 odontogenic cysts that were planned for excision. Three smears were prepared from the cell sediment obtained after centrifugation and stained. The stained sections were examined for presence and type of epithelial cells, to formulate a preopererative diagnosis. Epithelial cells were detected in 46% cases in smear 1, 48% cases in smear 2, and 52% cases in smear 3. When all three smears from one case were studied, 86% cases showed epithelial cells for evaluation. Cystic aspirate should be centrifuged and the entire cell sediment should be examined by making multiple smears for evaluation of cystic epithelial lining cells.

  17. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a Containment Level-III Laboratory as part of a Laboratory Risk Assessment Program

    PubMed Central

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-01

    Background In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating /chemical fixation) may not consistently kill MTB organisms. Methods An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Results Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80°C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. Conclusions This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in house biosafety-validated practices with the aim of protecting laboratory workers conducting these procedures. PMID:15667662

  18. Standardization of blood smears prepared in transparent acetate: an alternative method for the microscopic diagnosis of malaria.

    PubMed

    Mello, Marcia B C; Luz, Francisco C; Leal-Santos, Fabio A; Alves, Eduardo R; Gasquez, Thamires M; Fontes, Cor J F

    2014-06-17

    Due to students' initial inexperience, slides are frequently broken and blood smears are damaged in microscopy training, leading to the need for their constant replacement. To minimize this problem a method of preparing blood smears on transparent acetate sheets was developed with the goal of implementing appropriate and more readily available teaching resources for the microscopic diagnosis of malaria. Acetate sheets derived from polyester were used to standardize the preparation and staining of thin and thick blood smears on transparent acetate sheets. Thick and thin blood smears were also prepared using the conventional method on glass slides. The staining was conducted using Giemsa staining for the thick and thin smears. Microscopic examination (1,000x) of the thin and thick blood smears prepared on transparent acetate produced high-quality images for both the parasites and the blood cells. The smears showed up on a clear background and with minimal dye precipitation. It was possible to clearly identify the main morphological characteristics of Plasmodium, neutrophils and platelets. After 12 months of storage, there was no change in image quality or evidence of fungal colonization. Preparation of thin and thick blood smears in transparent acetate for the microscopic diagnosis of malaria does not compromise the morphological and staining characteristics of the parasites or blood cells. It is reasonable to predict the applicability of transparent acetate in relevant situations such as the training of qualified professionals for the microscopic diagnosis of malaria and the preparation of positive specimens for competency assessment (quality control) of professionals and services involved in the diagnosis of malaria.

  19. Factors associated with negative T-SPOT.TB results among smear-negative tuberculosis patients in China.

    PubMed

    Kang, Wanli; Wu, Meiying; Yang, Kunyun; Ertai, A; Wu, Shucai; Geng, Shujun; Li, Zhihui; Li, Mingwu; Pang, Yu; Tang, Shenjie

    2018-03-09

    We compared the positive rates of T-SPOT.TB and bacterial culture in the smear-negative PTB, and analyzed the factors affecting the results of negative T-SPOT.TB and bacterial culture. Retrospective evaluation of data from smear-negative PTB patients who underwent T-SPOT.TB and bacterial culture were done. The agreement and concordance were analyzed between T-SPOT.TB and bacterial culture. Multivariable logistic regression analysis was used to explore the factors associated with positive results of T-SPOT.TB and bacterial culture in smear-negative PTB. 858 eligible smear-negative PTB patients were included in the study. The agreement rate was 25.6% (22.7~28.5%) between T-SPOT.TB and bacterial culture in smear- negative PTB patients. The positive rate of T-SPOT.TB was higher than that of bacterial culture in smear-negative PTB patients (p < 0.001). There were nearly no concordance between T-SPOT.TB and bacterial culture (p > 0.05). Using multivariable logistic regression analysis we found that older age ≥ 60 years (OR = 0.469, 95% CI: 0.287-0.768) and decreased albumin (OR = 0.614, 95% CI: 0.380-0.992) were associated with negative diagnostic results of T-SPOT.TB in smear-negative PTB patients. Female (OR = 0.654, 95% CI: 0.431-0.992) were associated with negative diagnostic results of bacteria culture in smear-negative PTB patients. Our results indicated that the older age and decreased albumin were independently associated with negative T-SPOT.TB responses.

  20. The agreement between self-reported cervical smear abnormalities and screening programme records.

    PubMed

    Canfell, Karen; Beral, Valerie; Green, Jane; Cameron, Rebecca; Baker, Krys; Brown, Anna

    2006-01-01

    The Million Women Study is a cohort study of women aged 50-64 years in England and Scotland. As a component of the follow-up questionnaire, participants were asked to indicate if they had an abnormal cervical smear in the previous five years. This study compared self-reported cervical abnormalities with screening records obtained from the National Health Service Cervical Screening Programme. For 1944 randomly selected Million Women Study participants in Oxfordshire, screening records were assessed over a six-year period prior to the date of self-reporting. The six-year period was chosen to allow for errors in the recall of timing of abnormal smears. A total of 68 women (3.5%) had a record of at least one equivocal or abnormal smear within the last six years, whereas 49 women (2.5%) self-reported an abnormality. There was a strong trend for an increased probability of self-reporting a history of an abnormal smear as the severity of the recorded abnormality increased (P <0.001). For women with an NHS record of borderline dyskaryosis, mild dyskaryosis, or moderate dyskaryosis/severe dyskaryosis/invasive cancer, the proportions reporting an abnormality were 40%, 58% and 77%, respectively. For women with negative and inadequate smears, the proportion self-reporting an abnormality were 0.6% and 0.7%, respectively. These results indicate that among women whose screening programme records show an abnormal smear, the proportion self-reporting an abnormality increases with the severity of the recorded lesion. Almost all women with a record of negative or inadequate smear(s) correctly interpret the result and do not self-report an abnormality.

  1. Agar Block Smear Preparation: a Novel Method of Slide Preparation for Preservation of Native Fungal Structures for Microscopic Examination and Long-Term Storage▿

    PubMed Central

    Woo, Patrick C. Y.; Ngan, Antonio H. Y.; Chui, Hon-Kit; Lau, Susanna K. P.; Yuen, Kwok-Yung

    2010-01-01

    We describe a novel method of fungal slide preparation named “agar block smear preparation.” A total of 510 agar block smears of 25 fungal strains obtained from culture collections, 90 QC fungal strains, and 82 clinical fungal strains from our clinical microbiology laboratory, which included a total of 137 species of yeasts, molds, and thermal dimorphic fungi, were prepared and examined. In contrast to adhesive tape preparation, agar block smears preserved the native fungal structures, such as intact conidiophores of Aspergillus species and arrangements of conidia in Scopulariopsis brevicaulis. Furthermore, agar block smears allowed examination of fungal structures embedded in the agar, such as the ascomata with ascomal hairs in Chaetomium funicola; pycnidium of Phoma glomerata; the intercalary ovoidal chlamydospores arranged in chains of Fusarium dimerum; and the lateral, spherical chlamydospores arranged in pairs of Fusarium solani. After 1 year of storage, morphological integrity was found to have been maintained in 459 (90%) of the 510 agar block smears. After 3 years of storage, morphological integrity was found to have been maintained in 72 (71%) of the 102 smears prepared in 2006. Agar block smear preparation preserves the native fungal structures and allows long-term storage and examination of fungal structures embedded in the agar, hence overcoming the major drawbacks of adhesive tape preparation. The major roles of agar block smear should be diagnosis for difficult cases, accurate identification of fungal species for clinical management of patients and epidemiological studies, and long-term storage for transportation of slides and education purposes. PMID:20660221

  2. Agar block smear preparation: a novel method of slide preparation for preservation of native fungal structures for microscopic examination and long-term storage.

    PubMed

    Woo, Patrick C Y; Ngan, Antonio H Y; Chui, Hon-Kit; Lau, Susanna K P; Yuen, Kwok-Yung

    2010-09-01

    We describe a novel method of fungal slide preparation named "agar block smear preparation." A total of 510 agar block smears of 25 fungal strains obtained from culture collections, 90 QC fungal strains, and 82 clinical fungal strains from our clinical microbiology laboratory, which included a total of 137 species of yeasts, molds, and thermal dimorphic fungi, were prepared and examined. In contrast to adhesive tape preparation, agar block smears preserved the native fungal structures, such as intact conidiophores of Aspergillus species and arrangements of conidia in Scopulariopsis brevicaulis. Furthermore, agar block smears allowed examination of fungal structures embedded in the agar, such as the ascomata with ascomal hairs in Chaetomium funicola; pycnidium of Phoma glomerata; the intercalary ovoidal chlamydospores arranged in chains of Fusarium dimerum; and the lateral, spherical chlamydospores arranged in pairs of Fusarium solani. After 1 year of storage, morphological integrity was found to have been maintained in 459 (90%) of the 510 agar block smears. After 3 years of storage, morphological integrity was found to have been maintained in 72 (71%) of the 102 smears prepared in 2006. Agar block smear preparation preserves the native fungal structures and allows long-term storage and examination of fungal structures embedded in the agar, hence overcoming the major drawbacks of adhesive tape preparation. The major roles of agar block smear should be diagnosis for difficult cases, accurate identification of fungal species for clinical management of patients and epidemiological studies, and long-term storage for transportation of slides and education purposes.

  3. Porcine dermis compared with polypropylene mesh for laparoscopic sacrocolpopexy: a randomized controlled trial.

    PubMed

    Culligan, Patrick J; Salamon, Charbel; Priestley, Jennifer L; Shariati, Amir

    2013-01-01

    To compare the surgical outcomes 12 months after laparoscopic sacrocolpopexy performed with porcine dermis and the current gold standard of polypropylene mesh. Patients scheduled for laparoscopic sacrocolpopexy were eligible for this randomized controlled trial. Both our clinical research nurse and the patients were blinded as to which material was used. Our primary end point was objective anatomic cure defined as no pelvic organ prolapse quantification (POP-Q) points Stage 2 or greater at any postoperative interval. Our sample size calculation called for 57 patients in each group to achieve 90% power to detect a 23% difference in objective anatomic cure at 12 months (α=0.05). Our secondary end point was clinical cure. Any patient with a POP-Q point greater than zero, or Point C less than or equal to -5, or any complaints of prolapse symptoms whatsoever on Pelvic Floor Distress Inventory-20 or Pelvic Floor Impact Questionnaire, Short Form 7, or reoperation for prolapse were considered "clinical failures"; the rest were "clinical cures." Statistical comparisons were performed using the χ or independent samples t test as appropriate. As expected, there were no preoperative differences between the porcine (n=57) and mesh (n=58) groups. The 12-month objective anatomic cure rates for the porcine and mesh groups were 80.7% and 86.2%, respectively (P=.24), and the "clinical cure" rates for the porcine and mesh groups were 84.2% and 89.7%, respectively (P=.96). Pelvic Floor Distress Inventory-20 and Pelvic Floor Impact Questionnaire, Short Form 7 score improvements were significant for both groups with no differences found between groups. There were no major operative complications. There were similar outcomes in subjective or objective results 12 months after laparoscopic sacrocolpopexy performed with either porcine dermis or polypropylene mesh. ClinicalTrials.gov, www.clinicaltrials.gov, NCT00564083. I.

  4. An epidemiological study of Cryptosporidium parvum in two herds of adult beef cattle.

    PubMed

    Scott, C A; Smith, H V; Mtambo, M M; Gibbs, H A

    1995-04-01

    Prevalences of Cryptosporidium parvum oocysts in faeces and of isotype-specific anti-C. parvum antibodies in serum of apparently healthy adult cattle on two farms were determined. On Farm 1 cryptosporidial diarrhoea had been recorded in more than 80% of calves born over the previous 5 years, whereas on Farm 2 cryptosporidiosis had never been reported. No differences were demonstrated in oocyst excretion or presence of antibodies between the two farms. C. parvum oocysts were detected in 62.4% of faecal smears collected from a total of 553 apparently healthy adult cattle. Sucrose flotation was performed on a proportion of the faecal samples. This proved a more sensitive technique, detecting oocysts in 92% of the samples tested, and highlighting the insensitivity of direct smears for detecting oocysts. More than 90% of the cattle had specific anti-C. parvum IgG, IgG1, IgG2 and IgM antibodies and 58% specific anti-C. parvum IgA antibodies. Results suggest that asymptomatic adults may play an important role in the epidemiology of cryptosporidiosis in calves.

  5. Human papillomavirus prevalence, cervical abnormalities and risk factors among female sex workers in Lima, Peru

    PubMed Central

    Brown, B; Blas, M M; Cabral, A; Byraiah, G; Guerra-Giraldez, C; Sarabia-Vega, V; Carcamo, C; Gravitt, P E; Halsey, N A

    2015-01-01

    Summary Female sex workers (FSWs) are at high risk of human papillomavirus (HPV) infection. Questionnaires were administered to 200 FSWs aged 18–26 years in Lima, Peru, to gather risk behaviours, and cervical swab samples were collected for Pap smears and HPV DNA testing as part of a longitudinal study. Participants reported a median of 120 clients in the past month, and 99.2% reported using condoms with clients. The prevalence of any HPV in cervical samples was 66.8%; 34 (17.1%) participants had prevalent HPV 16 or 18, and 92 (46.2%) had one or more oncogenic types. Fifteen women had abnormal Pap smears, 13 of which were HPV DNA positive. Fewer years since first sex was associated with oncogenic HPV prevalence in a model adjusted for previous sexually transmitted infection (STI) status and condom use with partners (prevalence ratio = 0.77, 95% confidence interval [CI] = 0.60–0.97). Our data confirm the high rates of HPV transmission among FSWs in Peru, highlighting the need for early and effective strategies to prevent cervical cancer. PMID:22581946

  6. Utility of a Fluorescence Microscopy Imaging System for Analyzing the DNA Ploidy of Pathological Megakaryocytes Including 5q- Syndrome.

    PubMed

    Nakahara, Takako; Suemori, Shinichiro; Tsujioka, Takayuki; Kataoka, Mikio; Kataoka, Hiromi; Shibakura, Misako; Tohyama, Kaoru

    2018-06-01

    To investigate megakaryocyte (MK) DNA ploidy in various hematological diseases, fluorescence microscopy imaging system (FMI) can be used to analyze DNA ploidy with cell morphology at the single-cell level by using specialized image-processing software. Here we compared DNA ploidy obtained by FMI measured with that obtained flow cytometry (FCM). With FMI, we could evaluate the DNA ploidy in long-term preserved bone marrow smear samples after staining. We next analyzed the MK DNA ploidy in 42 bone marrow smear samples including 26 myeloid neoplasm cases, and we compared the DNA ploidy and platelet counts in the patients' peripheral blood; the production of platelets was significantly high compared to DNA ploidy in the myeloproliferative neoplasms group. The FMI method revealed that the patients with 5q- syndrome exhibited relatively low DNA ploidy despite high platelet counts, and this result suggested that increased DNA ploidy is not indispensable to abundant platelet production. The FMI method for DNA ploidy will be a useful tool to clarify the relationship between DNA ploidy and platelet production by MKs.

  7. Diagnosis of Carrion’s Disease by Direct Blood PCR in Thin Blood Smear Negative Samples

    PubMed Central

    Tinco Valdez, Carmen; Pons, Maria J.; del Valle, Luis J.; Oré, Verónica Casabona; Michelena, Denisse Champin; Mayra, Jorge Bazán; Gavidea, Víctor Zavaleta; Vargas, Martha; Ruiz, Joaquim

    2014-01-01

    Bartonella bacilliformis is the etiologic agent of Carrion's disease. This disease has two well established phases, the most relevant being the so called Oroya Fever, in which B. bacilliformis infect the erythrocytes resulting in severe anemia and transient immunosuppression, with a high lethality in the absence of adequate antibiotic treatment. The presence of B. bacilliformis was studied in 113 blood samples suspected of Carrion’s disease based on clinical criteria, despite the absence of a positive thin blood smear, by two different PCR techniques (using Bartonella-specific and universal 16S rRNA gene primers), and by bacterial culture. The specific 16S rRNA gene primers revealed the presence of 21 B. bacilliformis and 1 Bartonella elizabethae, while universal primers showed both the presence of 3 coinfections in which a concomitant pathogen was detected plus Bartonella, in addition to the presence of infections by other microorganisms such as Agrobacterium or Bacillus firmus. These data support the need to implement molecular tools to diagnose Carrion’s disease. PMID:24651298

  8. Human papillomavirus prevalence, cervical abnormalities and risk factors among female sex workers in Lima, Peru.

    PubMed

    Brown, B; Blas, M M; Cabral, A; Byraiah, G; Guerra-Giraldez, C; Sarabia-Vega, V; Carcamo, C; Gravitt, P E; Halsey, N A

    2012-04-01

    Female sex workers (FSWs) are at high risk of human papillomavirus (HPV) infection. Questionnaires were administered to 200 FSWs aged 18-26 years in Lima, Peru, to gather risk behaviours, and cervical swab samples were collected for Pap smears and HPV DNA testing as part of a longitudinal study. Participants reported a median of 120 clients in the past month, and 99.2% reported using condoms with clients. The prevalence of any HPV in cervical samples was 66.8%; 34 (17.1%) participants had prevalent HPV 16 or 18, and 92 (46.2%) had one or more oncogenic types. Fifteen women had abnormal Pap smears, 13 of which were HPV DNA positive. Fewer years since first sex was associated with oncogenic HPV prevalence in a model adjusted for previous sexually transmitted infection (STI) status and condom use with partners (prevalence ratio = 0.77, 95% confidence interval [CI] = 0.60-0.97). Our data confirm the high rates of HPV transmission among FSWs in Peru, highlighting the need for early and effective strategies to prevent cervical cancer.

  9. A scanning electron microscopy study of diseased root surfaces conditioned with EDTA gel plus Cetavlon after scaling and root planing.

    PubMed

    Martins Júnior, Walter; De Rossi, Andiara; Samih Georges Abi Rached, Ricardo; Rossi, Marcos Antonio

    2011-01-01

    In the present investigation, a scanning electron microscopy analysis was performed to evaluate the effects of the topical application of ethylenediaminetetraacetic acid (EDTA) gel associated with Cetavlon (EDTAC) in removing the smear layer and exposing collagen fibers following root surface instrumentation. Twenty-eight teeth from adult humans, single rooted and scheduled for extraction due to periodontal reasons, were selected. Each tooth was submitted to manual (scaling and root planing) instrumentation alone or combined with ultrasonic instruments, with or without etching using a 24% EDTAC gel. Following extraction, specimens were processed and examined under a scanning electron microscope. A comparative morphological semi-quantitative analysis was performed; the intensity of the smear layer and the decalcification of cementum and dentinal surfaces were graded in 12 sets using an arbitrary scale ranging from 1 (area covered by a smear layer) to 4 (no smear layer). Root debridement with hand instruments alone or combined with ultrasonic instruments resulted in a similar smear layer covering the root surfaces. The smear layer was successfully removed from the surfaces treated with EDTAC, which exhibited numerous exposed dentinal tubules and collagen fibers. This study supports the hypothesis that manual instrumentation alone or instrumentation combined with ultrasonic instrumentation is unable to remove the smear layer, whereas the subsequent topical application of EDTAC gel effectively removes the smear layer, uncovers dentinal openings and exposes collagen fibers.

  10. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study

    PubMed Central

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A.; Chauhan, Sunanda

    2018-01-01

    Background: Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. Materials and Methods: We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. Results: We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Conclusions: Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material. PMID:29643653

  11. It's like night and day: Diel net-effects on Cercopagidae densities in the Laurentian Great Lakes

    USGS Publications Warehouse

    Armenio, Patricia M.; Bunnell, David B.; Adams, Jean V.; Watson, Nicole M.; Woelmer, Whitney

    2017-01-01

    In the Laurentian Great Lakes, zooplankters are often sampled using standard ≤153 μm mesh nets without regard to the time of day they are collected. We sampled Cercopagidae during 2013–2014 in northern Lake Huron during day, dusk, and night using two different nets (a 0.5 m wide 153 μm mesh “standard” net and a 0.75 m wide 285 μm mesh “Bythotrephes” net) to determine if there were any differences in their sampled densities. Bythotrephes densities with the standard net were approximately 2.07-fold greater when captured at night than during the day. No time of day bias occurred with the Bythotrephes net. Nighttime Bythotrephes densities did not differ between the two net types. Cercopagis densities did not vary with net type or the time of day in this study, but future work should revisit this result given our low sample size and the low occurrence of Cercopagis in Lake Huron. To reduce bias and calculate accurate density estimates, Cercopagidae should be sampled at night if using a standard net or any time of day with the Bythotrephes net. Given the large impact of invasive predatory cladocerans Bythotrephes longimanus and Cercopagis pengoi on food webs since their invasion in the Laurentian Great Lakes in the 1980s, proper estimation of their densities is essential.

  12. Osseointegrated dental implants produced via microwave processing

    NASA Astrophysics Data System (ADS)

    Kutty, Muralithran G.

    This research is a comprehensive effort to develop osseointegrated dental implants via microwave processing. A net-shape microwave sintering procedure was employed to fabricate dental implants. Commercial pure titanium powders (-100, -200 and -325 mesh sizes) were used in this work. This process eliminates the need for machining of implants and prevents contamination. The idea was to take advantage of the peculiar way microwave couple with metallic powders, i.e. generating heat in the interior of the sample and dissipating it away through the surface. The desired features for an implant, a dense core with surface pores, is not possible via conventional sintering. Coating with hydroxyapatite via electrodeposition and chemical combustion vapor deposition was also attempted to further enhance the bioactivity of this layer. Surface roughness and area were measured using a non-contact surface profilometer to further describe the unique surface. In-vitro studies, conducted using osteoblast cells extracted from neonatal rat calvarial, showed improved cell growth on all the uncoated porous samples. However, the highest cell growth was observed on the -200 mesh size samples. The higher surface area of the -200 mesh samples is attributed to this observation. This work was able to identify the processing parameters for titanium in microwave and establishes the importance of surface area as a key parameter for cell growth on porous surfaces as compared to surface roughness.

  13. A Study of Pap Smear in HIV-Positive Females.

    PubMed

    Madan, Apeksha; Patil, Sunita; Nakate, Leena

    2016-12-01

    HIV-positive females are more likely to have abnormal Pap smears than HIV-negative women. These abnormal Pap smears are usually associated with low CD4 cell counts and human papilloma virus infection. This was a prospective hospital-based study from April 2013 till March 2014. A total of 250 (both symptomatic and asymptomatic) HIV-positive females were examined in Gynaecology OPD at R.C.S.M. G.M.C and C.P.R. Hospital, Kolhapur, and their cervical smears were taken. They were categorized as per modified Bethesda system 2001. The findings in HIV-positive women were correlated with risk factors (age, disease duration, CD4 count and ART use). To study the spectrum of cytological abnormalities on Pap smear in HIV-positive females and classify precancerous and cancerous lesions in HIV-positive females according to Bethesda system 2001 and to be familiar with terminology and morphological criteria of Bethesda system 2001. To study the association of Pap smears abnormalities among HIV-positive women with their immune status (CD4 count). NILM is the commonest finding (83.2 %) which is subdivided into non-inflammatory, non-specific and specific inflammatory and atrophic smears. Candida vaginitis was the commonest cause of specific inflammatory condition accounted for (2.52 %) of all inflammatory smears. The percentage of squamous cell abnormalities was 12 %: ASCUS + ASC-H-6.22 %, LSIL-2.10 %, HSIL-3.4 % and SCC-0.8 %. The highest incidence of intraepithelial lesions in HIV-positive females was in the age group 31-40 years. There is no association of Pap smear abnormalities among HIV-positive women with their immune status (CD4 count) and duration of ART. Periodic, regular gynaecologic and Pap smear examination would help in early detection of intraepithelial lesions and their treatment so as to prevent invasive malignancy and mortality.

  14. Crystallization and demineralization phenomena in washed-rind cheese.

    PubMed

    Tansman, Gil F; Kindstedt, Paul S; Hughes, John M

    2017-11-01

    This report documents an observational study of a high-moisture washed-rind cheese. Three batches of cheese were sampled on a weekly basis for 6 wk and again at wk 10. Center, under-rind, rind, and smear samples were tested for pH, moisture, and selected mineral elements. Powder x-ray diffractometry and petrographic microscopy were applied to identify and image the crystal phases. The pH of the rind increased by over 2 pH units by wk 10. The pH of the under-rind increased but remained below the rind pH, whereas the center pH decreased for most of aging and only began to rise after wk 5. Diffractograms of smear material revealed the presence of 4 crystal phases: brushite, calcite, ikaite, and struvite. The phases nucleated in succession over the course of aging, with calcite and ikaite appearing around the same time. A very small amount of brushite appeared sporadically in center and under-rind samples, but otherwise no other crystallization was observed beneath the rind. Micrographs revealed that crystals in the smear grew to over 250 μm in length by wk 10, and at least 2 different crystal phases, probably ikaite and struvite, could be differentiated by their different optical properties. The surface crystallization was accompanied by a mineral diffusion phenomenon that resulted, on average, in a 217, 95.7, and 149% increase in calcium, phosphorus, and magnesium, respectively, in the rind by wk 10. The diffusion phenomenon caused calcium, phosphorus, and magnesium to decrease, on average, by 55.0, 21.5, and 36.3%, respectively, in the center by wk 10. The present study represents the first observation of crystallization and demineralization phenomena in washed-rind cheese. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).

  15. Comparative performance of Thin Layer Agar and Löwenstein-Jensen culture for diagnosis of tuberculosis.

    PubMed

    Battaglioli, T; Rintiswati, N; Martin, A; Palupi, K R; Bernaerts, G; Dwihardiani, B; Ahmad, R A; Matthys, F; Mahendradhata, Y; Van der Stuyft, P

    2013-11-01

    Sputum smear microscopy for the diagnosis of tuberculosis (TB) is cheap and simple but its sensitivity is low. Culture on Löwenstein-Jensen (LJ) is more sensitive but it takes a long time to yield results. Thin-Layer Agar (TLA) culture was suggested as an equally sensitive and faster alternative. We evaluated the performance of TLA for diagnosing TB in Jogjakarta, Indonesia. People with suspected TB presenting from July 2010 to July 2011 to two chest clinics of the National TB Control Programme network of Jogjakarta were eligible for inclusion. A sputum sample was sent to the Gadjah Mada University microbiology laboratory for concentration, smearing, Ziehl-Neelsen staining and culture on LJ and TLA. Sensitivity of cultures was evaluated against a composite reference standard (any positive culture). Time to detection of Mycobacteria was recorded. Out of 1414 samples, 164 (12%) were smear positive, 99 (7%) were scanty and 1151 (81%) were negative. On TLA and LJ respectively, 168 (12%) and 149 (11%) samples were positive, 72 (5%) and 32 (2%) were contaminated (κ = 0.64; 95% CI 0.59-0.69, p <0.01). Using the reference standard, 196 (14%) TB cases were identified. The sensitivity of TLA was 0.86 (95% CI 0.80-0.90), significantly higher (p 0.03) than for LJ (0.76; 95% CI 0.69-0.81). The median time to detection in days was significantly shorter (p <0.01) for TLA (12; 95% CI 11-13) than for LJ (44; 95% CI 43-45). TLA is a rapid and sensitive method for the diagnosis of TB. Implementation studies to evaluate the cost-effectiveness and impact of its introduction into programmatic settings are urgently needed. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  16. Evaluation of the Abbott RealTime MTB and RealTime MTB INH/RIF Assays for Direct Detection of Mycobacterium tuberculosis Complex and Resistance Markers in Respiratory and Extrapulmonary Specimens.

    PubMed

    Hofmann-Thiel, Sabine; Molodtsov, Nikolay; Antonenka, Uladzimir; Hoffmann, Harald

    2016-12-01

    The Abbott RealTime MTB (RT MTB) assay is a new automated nucleic acid amplification test for the detection of Mycobacterium tuberculosis complex (MTBC) in clinical specimens. In combination with the RealTime MTB INH/RIF (RT MTB INH/RIF) resistance assay, which can be applied to RT MTB-positive specimens as an add-on assay, the tests also indicate the genetic markers of resistance to isoniazid (INH) and rifampin (RIF). We aimed to evaluate the diagnostic sensitivity and specificity of RT MTB using different types of respiratory and extrapulmonary specimens and to compare performance characteristics directly with those of the FluoroType MTB assay. The resistance results obtained by RT MTB INH/RIF were compared to those from the GenoType MTBDRplus and from phenotypic drug susceptibility testing. A total of 715 clinical specimens were analyzed. Compared to culture, the overall sensitivity of RT MTB was 92.1%; the sensitivity rates for smear-positive and smear-negative samples were 100% and 76.2%, respectively. The sensitivities of smear-negative specimens were almost identical for respiratory (76.3%) and extrapulmonary (76%) specimens. Specificity rates were 100% and 95.8% for culture-negative specimens and those that grew nontuberculous mycobacteria, respectively. RT MTB INH/RIF was applied to 233 RT MTB-positive samples and identified resistance markers in 7.7% of samples. Agreement with phenotypic and genotypic drug susceptibility testing was 99.5%. In conclusion, RT MTB and RT MTB INH/RIF allow for the rapid and accurate diagnosis of tuberculosis (TB) in different types of specimens and reliably indicate resistance markers. The strengths of this system are the comparably high sensitivity with paucibacillary specimens, its ability to detect INH and RIF resistance, and its high-throughput capacities. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  17. Pilot Study of an Open-source Image Analysis Software for Automated Screening of Conventional Cervical Smears.

    PubMed

    Sanyal, Parikshit; Ganguli, Prosenjit; Barui, Sanghita; Deb, Prabal

    2018-01-01

    The Pap stained cervical smear is a screening tool for cervical cancer. Commercial systems are used for automated screening of liquid based cervical smears. However, there is no image analysis software used for conventional cervical smears. The aim of this study was to develop and test the diagnostic accuracy of a software for analysis of conventional smears. The software was developed using Python programming language and open source libraries. It was standardized with images from Bethesda Interobserver Reproducibility Project. One hundred and thirty images from smears which were reported Negative for Intraepithelial Lesion or Malignancy (NILM), and 45 images where some abnormality has been reported, were collected from the archives of the hospital. The software was then tested on the images. The software was able to segregate images based on overall nuclear: cytoplasmic ratio, coefficient of variation (CV) in nuclear size, nuclear membrane irregularity, and clustering. 68.88% of abnormal images were flagged by the software, as well as 19.23% of NILM images. The major difficulties faced were segmentation of overlapping cell clusters and separation of neutrophils. The software shows potential as a screening tool for conventional cervical smears; however, further refinement in technique is required.

  18. Smearing the opposition: implicit and explicit stigmatization of the 2008 U.S. Presidential candidates and the current U.S. President.

    PubMed

    Kosloff, Spee; Greenberg, Jeff; Schmader, Toni; Dechesne, Mark; Weise, David

    2010-08-01

    Four studies investigated whether political allegiance and salience of outgroup membership contribute to the phenomenon of acceptance of false, stigmatizing information (smears) about political candidates. Studies 1-3 were conducted in the month prior to the 2008 U.S. Presidential election and together demonstrated that pre-standing opposition to John McCain or Barack Obama, as well as the situational salience of differentiating social categories (i.e., for Obama, race; for McCain, age), contributed to the implicit activation and explicit endorsement of smearing labels (i.e., Obama is Muslim; McCain is senile). The influence of salient differentiating categories on smear acceptance was particularly pronounced among politically undecided individuals. Study 4 clarified that social category differences heighten smear acceptance, even if the salient category is semantically unrelated to the smearing label, showing that, approximately 1 year after the election, the salience of race amplified belief that Obama is a socialist among undecided people and McCain supporters. Taken together, these findings suggest that, at both implicit and explicit cognitive levels, social category differences and political allegiance contribute to acceptance of smears against political candidates. 2010 APA, all rights reserved

  19. Acculturation and Pap smear screening practices among college-aged Vietnamese women in the United States.

    PubMed

    Yi, J K

    1998-10-01

    The purposes of this study were both to gather information on the prevalence of Pap smear screening among college-aged Vietnamese women and to identify predictive factors that influence Vietnamese women to engage in early cervical cancer detection behavior. This study also examines the role of acculturation in explaining cervical cancer screening behavior. Data were collected through mail and telephone surveys. Of those respondents (n = 207), approximately one-third (36.8%) reported having had a Pap smear. More than one-third (39.3%) of sexually active respondents reported never having had a Pap smear. Acculturated women were more likely to be sexually active and to be obtaining regular Pap smears. In the logistic regression model, marital status, sexual activity, and a belief that only married women should have a Pap smear were important predictors of prior reported Pap smear experience. These study findings suggest that less-acculturated women appear to have the belief that cervical cancer screening is more important for married women than for unmarried women, regardless of their sexual activity. The existence of such misconceptions underscores the importance of offering culturally relevant cancer education that addresses related misconceptions.

  20. A continuous quality improvement project to improve the quality of cervical Papanicolaou smears.

    PubMed

    Burkman, R T; Ward, R; Balchandani, K; Kini, S

    1994-09-01

    To improve the quality of cervical Papanicolaou smears by continuous quality improvement techniques. The study used a Papanicolaou smear data base of over 200,000 specimens collected between June 1988 and December 1992. A team approach employing techniques such as process flow-charting, cause and effect diagrams, run charts, and a randomized trial of collection methods was used to evaluate potential causes of Papanicolaou smear reports with the notation "inadequate" or "less than optimal" due to too few or absent endocervical cells. Once a key process variable (method of collection) was identified, the proportion of Papanicolaou smears with inadequate or absent endocervical cells was determined before and after employment of a collection technique using a spatula and Cytobrush. We measured the rate of less than optimal Papanicolaou smears due to too few or absent endocervical cells. Before implementing the new collection technique fully by June 1990, the overall rate of less than optimal cervical Papanicolaou smears ranged from 20-25%; by December 1993, it had stabilized at about 10%. Continuous quality improvement can be used successfully to study a clinical process and implement change that will lead to improvement.

  1. Effect of sampling and diagnostic effort on the assessment of schistosomiasis and soil-transmitted helminthiasis and drug efficacy: a meta-analysis of six drug efficacy trials and one epidemiological survey.

    PubMed

    Levecke, Bruno; Brooker, Simon J; Knopp, Stefanie; Steinmann, Peter; Sousa-Figueiredo, Jose Carlos; Stothard, J Russell; Utzinger, Jürg; Vercruysse, Jozef

    2014-12-01

    It is generally recommended to perform multiple stool examinations in order to improve the diagnostic accuracy when assessing the impact of mass drug administration programmes to control human intestinal worm infections and determining efficacy of the drugs administered. However, the collection and diagnostic work-up of multiple stool samples increases costs and workload. It has been hypothesized that these increased efforts provide more accurate results when infection and drug efficacy are summarized by prevalence (proportion of subjects infected) and cure rate (CR, proportion of infected subjects that become egg-negative after drug administration), respectively, but not when these indicators are expressed in terms of infection intensity and egg reduction rate (ERR). We performed a meta-analysis of six drug efficacy trials and one epidemiological survey. We compared prevalence and intensity of infection, CR and ERR based on collection of one or two stool samples that were processed with single or duplicate Kato-Katz thick smears. We found that the accuracy of prevalence estimates and CR was lowest with the minimal sampling effort, but that this was not the case for estimating infection intensity and ERR. Hence, a single Kato-Katz thick smear is sufficient for reporting infection intensity and ERR following drug treatment.

  2. Development of Antigen Detection Assay for Diagnosis of Tuberculosis Using Sputum Samples

    PubMed Central

    Pereira Arias-Bouda, Lenka M.; Nguyen, Lan N.; Ho, Ly M.; Kuijper, Sjoukje; Jansen, Henk M.; Kolk, Arend H. J.

    2000-01-01

    The rising incidence of tuberculosis worldwide means an increasing burden on diagnostic facilities, so tests simpler than Ziehl-Neelsen staining are needed. Such tests should be objective, reproducible, and have at least as good a detection limit as 104 bacteria/ml. A capture enzyme-linked immunosorbent assay (ELISA) was developed for detection of lipoarabinomannan (LAM) in human sputum samples. As a capture antibody, we used a murine monoclonal antibody against LAM, with rabbit antiserum against Mycobacterium tuberculosis as a source of detector antibodies. The sensitivity of the capture ELISA was evaluated by using purified LAM and M. tuberculosis whole cells. We were able to detect 1 ng of purified LAM/ml and 104 M. tuberculosis whole cells/ml. LAM could also be detected in culture filtrate of a 3-week-old culture of M. tuberculosis. The culture filtrate contained approximately 100 μg of LAM/ml. The detection limit in sputum pretreated with N-acetyl-l-cysteine and proteinase K was 104 M. tuberculosis whole cells per ml. Thirty-one (91%) of 34 sputum samples from 18 Vietnamese patients with tuberculosis (32 smear positive and 2 smear negative) were positive in the LAM detection assay. In contrast, none of the 25 sputum samples from 21 nontuberculous patients was positive. This specific and sensitive assay for the detection of LAM in sputum is potentially useful for the diagnosis of tuberculosis. PMID:10834989

  3. A computer program to generate two-dimensional grids about airfoils and other shapes by the use of Poisson's equation

    NASA Technical Reports Server (NTRS)

    Sorenson, R. L.

    1980-01-01

    A method for generating two dimensional finite difference grids about airfoils and other shapes by the use of the Poisson differential equation is developed. The inhomogeneous terms are automatically chosen such that two important effects are imposed on the grid at both the inner and outer boundaries. The first effect is control of the spacing between mesh points along mesh lines intersecting the boundaries. The second effect is control of the angles with which mesh lines intersect the boundaries. A FORTRAN computer program has been written to use this method. A description of the program, a discussion of the control parameters, and a set of sample cases are included.

  4. Smear correction of highly variable, frame-transfer CCD images with application to polarimetry.

    PubMed

    Iglesias, Francisco A; Feller, Alex; Nagaraju, Krishnappa

    2015-07-01

    Image smear, produced by the shutterless operation of frame-transfer CCD detectors, can be detrimental for many imaging applications. Existing algorithms used to numerically remove smear do not contemplate cases where intensity levels change considerably between consecutive frame exposures. In this report, we reformulate the smearing model to include specific variations of the sensor illumination. The corresponding desmearing expression and its noise properties are also presented and demonstrated in the context of fast imaging polarimetry.

  5. Alveolar Ridge Reconstruction with Titanium Meshes and Simultaneous Implant Placement: A Retrospective, Multicenter Clinical Study

    PubMed Central

    Paraud Freixas, Andres; Han, Chang-Hun; Bechara, Sohueil; Tawil, Isaac

    2016-01-01

    Objective. To evaluate horizontal bone gain and implant survival and complication rates in patients treated with titanium meshes placed simultaneously with dental implants and fixed over them. Methods. Twenty-five patients treated with 40 implants and simultaneous guided bone regeneration with titanium meshes (i–Gen®, MegaGen, Gyeongbuk, Republic of Korea) were selected for inclusion in the present retrospective multicenter study. Primary outcomes were horizontal bone gain and implant survival; secondary outcomes were biological and prosthetic complications. Results. After the removal of titanium meshes, the CBCT evaluation revealed a mean horizontal bone gain of 3.67 mm (±0.89). The most frequent complications were mild postoperative edema (12/25 patients: 48%) and discomfort after surgery (10/25 patients: 40%); these complications were resolved within one week. Titanium mesh exposure occurred in 6 patients (6/25 : 24%): one of these suffered partial loss of the graft and another experienced complete graft loss and implant failure. An implant survival rate of 97.5% (implant-based) and a peri-implant marginal bone loss of 0.43 mm (±0.15) were recorded after 1 year. Conclusions. The horizontal ridge reconstruction with titanium meshes placed simultaneously with dental implants achieved predictable satisfactory results. Prospective randomized controlled trials on a larger sample of patients are required to validate these positive outcomes. PMID:27999799

  6. Accuracy of dry vaginal self-sampling for detecting high-risk human papillomavirus infection in cervical cancer screening: a cross-sectional study.

    PubMed

    Haguenoer, K; Giraudeau, B; Gaudy-Graffin, C; de Pinieux, I; Dubois, F; Trignol-Viguier, N; Viguier, J; Marret, H; Goudeau, A

    2014-08-01

    Cervical cancer screening coverage remains insufficient in most countries. Testing self-collected samples for high-risk human papillomavirus (HR-HPV) could be an alternative to the Pap smear, but costs, sampling methods and transport issues hamper its wide use. Our objective was to compare diagnostic accuracy of 2 vaginal self-collection methods, a dry swab (vsc-DRY) or swab in liquid medium (vsc-LIQ), for detecting HR-HPV cervical infection assessed by a cervical clinician-collected sample in liquid medium (ccc-LIQ). Women 20 to 65 years attending a Pap smear were recruited between September, 2009 and March, 2011. Each sample (3 per woman) underwent HPV DNA testing. Samples were classified as HR-HPV+ with detection of at least one HR-HPV or probable HR-HPV type. Of 734 women included, 722 had complete HPV data. HR-HPV was detected in 20.9% of ccc-LIQ samples. Estimated sensitivity and specificity to detect HR-HPV in vsc-DRY samples were 88.7% and 92.5%, respectively, and in vsc-LIQ samples, 87.4% and 90.9%. Cytology findings were abnormal for 79 women (10.9%): among 27 samples of low-grade squamous intraepithelial lesions, 25 were HR-HPV+ in vsc-DRY, vsc-LIQ and ccc-LIQ samples. Among 6 samples of high-grade squamous intraepithelial lesions, all were HR-HPV+ in vsc-DRY samples, 1 was HR-HPV- in vsc-LIQ samples and 1 was HR-HPV- in ccc-LIQ samples. Vaginal self-sampling with a dry swab is accurate to detect HR-HPV infection as compared with cervical clinician-collection and accurate as compared with cytology results. This cheap and easy-to-ship sampling method could be widely used in a cervical cancer screening program. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Shear Alignment of Diblock Copolymers for Patterning Nanowire Meshes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gustafson, Kyle T.

    2016-09-08

    Metallic nanowire meshes are useful as cheap, flexible alternatives to indium tin oxide – an expensive, brittle material used in transparent conductive electrodes. We have fabricated nanowire meshes over areas up to 2.5 cm 2 by: 1) mechanically aligning parallel rows of diblock copolymer (diBCP) microdomains; 2) selectively infiltrating those domains with metallic ions; 3) etching away the diBCP template; 4) sintering to reduce ions to metal nanowires; and, 5) repeating steps 1 – 4 on the same sample at a 90° offset. We aligned parallel rows of polystyrene-b-poly(2-vinylpyridine) [PS(48.5 kDa)-b-P2VP(14.5 kDa)] microdomains by heating above its glass transition temperaturemore » (T g ≈ 100°C), applying mechanical shear pressure (33 kPa) and normal force (13.7 N), and cooling below T g. DiBCP samples were submerged in aqueous solutions of metallic ions (15 – 40 mM ions; 0.1 – 0.5 M HCl) for 30 – 90 minutes, which coordinate to nitrogen in P2VP. Subsequent ozone-etching and sintering steps yielded parallel nanowires. We aimed to optimize alignment parameters (e.g. shear and normal pressures, alignment duration, and PDMS thickness) to improve the quality, reproducibility, and scalability of meshes. We also investigated metals other than Pt and Au that may be patterned using this technique (Cu, Ag).« less

  8. Accuracy of next-generation sequencing for the identification of clinically relevant variants in cytology smears in lung adenocarcinoma.

    PubMed

    Baum, Jordan E; Zhang, Pan; Hoda, Rana S; Geraghty, Brian; Rennert, Hanna; Narula, Navneet; Fernandes, Helen D

    2017-06-01

    Minimally invasive diagnostic procedures such as needle-core biopsy and fine-needle aspiration provide adequate material for molecular analyses. Advances in precision oncology are trending toward the interrogation of limited amounts of genomic material to guide clinical and therapeutic decisions. The aim of this study was to investigate the minimum cellularity needed on cytologic smears for the identification of clinically relevant variants with next-generation sequencing (NGS). Thirty cases of cytologically diagnosed, resection-proven primary lung adenocarcinoma were identified. Nineteen of the 30 cases were known to harbor actionable variants. One Diff-Quik (DQ)-stained slide and 1 Papanicolaou (Pap)-stained slide were selected from each case. Cases were categorized as containing fewer than 100 tumor cells, 100 to 500 tumor cells, or more than 500 tumor cells. NGS was performed on the Ion Torrent platform. NGS was successfully performed on all cell blocks and on 90% of the smears. Paired DQ and Pap smears showed similar cellularity, and cases that differed in cellularity were within 1 category of each other. The cases with more than 100 tumor cells had a 93% success rate; this was significantly different from the situation for cases with fewer than 100 tumor cells, which were successfully sequenced only 67% of the time. Overall, NGS was able to provide clinically relevant information for 83% of DQ smears and for 90% of Pap smears tested. The data show a significantly higher likelihood of successful NGS with cytologic smears with more than 100 tumor cells. There was a trend for a higher NGS success rate with Pap smears versus DQ smears. Cancer Cytopathol 2017;125:398-406. © 2017 American Cancer Society. © 2017 American Cancer Society.

  9. Prevalence of tuberculous infection and incidence of tuberculosis; a re-assessment of the Styblo rule

    PubMed Central

    van der Werf, MJ; Borgdorff, MW

    2008-01-01

    Abstract Objective To evaluate the validity of the fixed mathematical relationship between the annual risk of tuberculous infection (ARTI), the prevalence of smear-positive tuberculosis (TB) and the incidence of smear-positive TB specified as the Styblo rule, which TB control programmes use to estimate the incidence of TB disease at a population level and the case detection rate. Methods Population-based tuberculin surveys and surveys on prevalence of smear-positive TB since 1975 were identified through a literature search. For these surveys, the ratio between the number of tuberculous infections (based on ARTI estimates) and the number of smear-positive TB cases was calculated and compared to the ratio of 8 to 12 tuberculous infections per prevalent smear-positive TB case as part of the Styblo rule. Findings Three countries had national population-based data on both ARTI and prevalence of smear-positive TB for more than one point in time. In China the ratio ranged from 3.4 to 5.8, in the Philippines from 2.6 to 4.4, and in the Republic of Korea, from 3.2 to 4.7. All ratios were markedly lower than the ratio that is part of the Styblo rule. Conclusion According to recent country data, there are typically fewer than 8 to 12 tuberculous infections per prevalent smear-positive TB case, and it remains unclear whether this ratio varies significantly among countries. The decrease in the ratio compared to the Styblo rule probably relates to improvements in the prompt treatment of TB disease (by national TB programmes). A change in the number of tuberculous infections per prevalent smear-positive TB case in population-based surveys makes the assumed fixed mathematical relationship between ARTI and incidence of smear-positive TB no longer valid. PMID:18235886

  10. Identification of multiple mRNA and DNA sequences from small tissue samples isolated by laser-assisted microdissection.

    PubMed

    Bernsen, M R; Dijkman, H B; de Vries, E; Figdor, C G; Ruiter, D J; Adema, G J; van Muijen, G N

    1998-10-01

    Molecular analysis of small tissue samples has become increasingly important in biomedical studies. Using a laser dissection microscope and modified nucleic acid isolation protocols, we demonstrate that multiple mRNA as well as DNA sequences can be identified from a single-cell sample. In addition, we show that the specificity of procurement of tissue samples is not compromised by smear contamination resulting from scraping of the microtome knife during sectioning of lesions. The procedures described herein thus allow for efficient RT-PCR or PCR analysis of multiple nucleic acid sequences from small tissue samples obtained by laser-assisted microdissection.

  11. Evaluation of nested PCR in diagnosis of fungal rhinosinusitis.

    PubMed

    Badiee, Parisa; Gandomi, Behrooz; Sabz, Gholamabbass; Khodami, Bijan; Choopanizadeh, Maral; Jafarian, Hadis

    2015-02-01

    Given the importance of rapid diagnosis for fungal rhinosinusitis, this study aimed to evaluate the use of nested PCR to identify Aspergillus and Mucor species in clinical samples from patients with suspected fungal rhinosinusitis. Functional endoscopic sinus surgery specimens were collected from 98 patients with rhinosinusitis from 2012 to 2013. All samples were ground and cultured on sabouraud dextrose agar. The isolated fungi were identified based on their macroscopic and microscopic features. Fungal DNA was extracted from the tissue samples and nested PCR was performed with two sets of primers for Mucor and Aspergillus. Direct microscopic showed that 5.1% contained fungal components and 9.2% exhibited growth of fungi in culture. The most common agents isolated were Aspergillus fumigatus (n= 3), Aspergillus flavus (n=2), Penicillium sp (n=3) and Alternaria sp. (n=1). Mucor sp. was identified in the pathology smear from 1 patient. Positive results for fungal rhinosinusitis were obtained for a total of 10.2% by culture or pathology smear. Positive PCR results were obtained in 72 samples for Aspergillus and 31 samples for Mucor. Our results suggest that endoscopic sinus surgery specimens are not suitable for nested PCR, probably because of the accumulation of fungi that contaminate the environmental air. This drawback is a limiting factor for diagnosis with nasal cavity specimens. Therefore, molecular methods and conventional culture techniques are helpful complementary diagnostic methods to detect fungal rhinosinusitis and determine appropriate management for these patients.

  12. An evaluation of smear layer with various desensitizing agents after tooth preparation.

    PubMed

    Zaimoglu, A; Aydin, A K

    1992-09-01

    According to hydrodynamics, any agent blocking the dentinal tubules reduces the flow of fluids and diminishes hypersensitivity. The properties of the desensitizing agents that sponsor tubular occlusion and the barrier efficiency resulting from the interaction of the smear layer with test materials were examined with the scanning electron microscope and energy-dispersive x-ray microanalysis. Selected dentinal desensitizing was accomplished with burnishing procedures, cavity varnish, calcium hydroxide, and topical fluoride. Subjective evaluations were also recorded clinically after tooth preparation. This investigation indicated that the smear layer did not protect against zinc phosphate cement, and that cavity varnish prevented the formation of the smear plugs. The smear layer and plugs were basically composed of calcium and phosphorus, the major ingredients of dentin.

  13. Terbinafine-loaded wound dressing for chronic superficial fungal infections.

    PubMed

    Paskiabi, Farnoush Asghari; Bonakdar, Shahin; Shokrgozar, Mohammad Ali; Imani, Mohammad; Jahanshiri, Zahra; Shams-Ghahfarokhi, Masoomeh; Razzaghi-Abyaneh, Mehdi

    2017-04-01

    In spite of developing new drugs and modern formulations, the treatments of chronic fungal infections are still challenging. Fibrous wound dressings are new suggestions for the treatment of chronic superficial infections. In the present study, we formulated an antifungal agent, terbinafine hydrochloride (TFH), which is a hydrophobic drug, in wound dressings prepared by electrospun polycaprolactone, polycaprolactone/gelatin (50:50 w/w) and gelatin. To obtain more water-stable meshes, the preparations were treated by glutaraldehyde and their properties were determined before and after treatment. The morphology of fibrous meshes was observed by scanning electron microscopy. Drug loading efficiency and release rate were measured by high performance liquid chromatography (HPLC) and the release rate was monitored for 144h. Antifungal tests were performed on Trichophyton mentagrophytes, Aspergillus fumigatus and Candida albicans cultured on Muller-Hinton agar. The toxicity of the meshes was measured after 24h and 14days by MTT assay. Terbinafine loading of polycaprolactone/gelatin (50:50) was 100% and it released the highest amount of TFH too. In antifungal tests, all samples were able to hinderT. mentagrophytes and A. fumigatus but not C. albicans growth among them, polycaprolactone fibers made the largest inhibition zone. In MTT assay, none of prepared samples showed toxicity against L929 cells. Teken together, the prepared TFH-loaded PCL/gelatin electrospun meshes were able to release TFH slowly and in a steady state in time. With respect to no obvious cytotoxicity in MTT assay and stong antifungal activity toward T. mentagrophytesin vitro, these TFH-based meshes could be considered as potential candidates in clinical application as wound dressing for treatment of chronic dermatophytosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Statistical Analysis of Compressive and Flexural Test Results on the Sustainable Adobe Reinforced with Steel Wire Mesh

    NASA Astrophysics Data System (ADS)

    Jokhio, Gul A.; Syed Mohsin, Sharifah M.; Gul, Yasmeen

    2018-04-01

    It has been established that Adobe provides, in addition to being sustainable and economic, a better indoor air quality without spending extensive amounts of energy as opposed to the modern synthetic materials. The material, however, suffers from weak structural behaviour when subjected to adverse loading conditions. A wide range of mechanical properties has been reported in literature owing to lack of research and standardization. The present paper presents the statistical analysis of the results that were obtained through compressive and flexural tests on Adobe samples. Adobe specimens with and without wire mesh reinforcement were tested and the results were reported. The statistical analysis of these results presents an interesting read. It has been found that the compressive strength of adobe increases by about 43% after adding a single layer of wire mesh reinforcement. This increase is statistically significant. The flexural response of Adobe has also shown improvement with the addition of wire mesh reinforcement, however, the statistical significance of the same cannot be established.

  15. Large accumulation of micro-sized synthetic polymer particles in the sea surface microlayer.

    PubMed

    Song, Young Kyoung; Hong, Sang Hee; Jang, Mi; Kang, Jung-Hoon; Kwon, Oh Youn; Han, Gi Myung; Shim, Won Joon

    2014-08-19

    Determining the exact abundance of microplastics on the sea surface can be susceptible to the sampling method used. The sea surface microlayer (SML) can accumulate light plastic particles, but this has not yet been sampled. The abundance of microplastics in the SML was evaluated off the southern coast of Korea. The SML sampling method was then compared to bulk surface water filtering, a hand net (50 μm mesh), and a Manta trawl net (330 μm mesh). The mean abundances were in the order of SML water > hand net > bulk water > Manta trawl net. Fourier transform infrared spectroscopy (FTIR) identified that alkyds and poly(acrylate/styrene) accounted for 81 and 11%, respectively, of the total polymer content of the SML samples. These polymers originated from paints and the fiber-reinforced plastic (FRP) matrix used on ships. Synthetic polymers from ship coatings should be considered to be a source of microplastics. Selecting a suitable sampling method is crucial for evaluating microplastic pollution.

  16. A real-time, quantitative PCR protocol for assessing the relative parasitemia of Leucocytozoon in waterfowl.

    PubMed

    Smith, Matthew M; Schmutz, Joel; Apelgren, Chloe; Ramey, Andrew M

    2015-04-01

    Microscopic examination of blood smears can be effective at diagnosing and quantifying hematozoa infections. However, this method requires highly trained observers, is time consuming, and may be inaccurate for detection of infections at low levels of parasitemia. To develop a molecular methodology for identifying and quantifying Leucocytozoon parasite infection in wild waterfowl (Anseriformes), we designed a real-time, quantitative PCR protocol to amplify Leucocytozoon mitochondrial DNA using TaqMan fluorogenic probes and validated our methodology using blood samples collected from waterfowl in interior Alaska during late summer and autumn (n=105). By comparing our qPCR results to those derived from a widely used nested PCR protocol, we determined that our assay showed high levels of sensitivity (91%) and specificity (100%) in detecting Leucocytozoon DNA from host blood samples. Additionally, results of a linear regression revealed significant correlation between the raw measure of parasitemia produced by our qPCR assay (Ct values) and numbers of parasites observed on blood smears (R(2)=0.694, P=0.003), indicating that our assay can reliably determine the relative parasitemia levels among samples. This methodology provides a powerful new tool for studies assessing effects of haemosporidian infection in wild avian species. Published by Elsevier B.V.

  17. A novel automatic molecular test for detection of multidrug resistance tuberculosis in sputum specimen: A case control study.

    PubMed

    Li, Qiang; Ou, Xi C; Pang, Yu; Xia, Hui; Huang, Hai R; Zhao, Bing; Wang, Sheng F; Zhao, Yan L

    2017-07-01

    MiniLab tuberculosis (ML TB) assay is a new automatic diagnostic tool for diagnosis of multidrug resistance tuberculosis (MDR-TB). This study was conducted with aims to know the performance of this assay. Sputum sample from 224 TB suspects was collected from tuberculosis suspects seeking medical care at Beijing Chest hospital. The sputum samples were directly used for smear and ML TB test. The left sputum sample was used to conduct Xpert MTB/RIF, Bactec MGIT culture and drug susceptibility test (DST). All discrepancies between the results from DST, molecular and phenotypic methods were confirmed by DNA Sequencing. The sensitivity and specificity of ML TB test for detecting MTBC from TB suspects were 95.1% and 88.9%, respectively. The sensitivity for smear negative TB suspects was 64.3%. For detection of RIF resistance, the sensitivity and specificity of ML TB test were 89.2% and 95.7%, respectively. For detection of INH resistance, the sensitivity and specificity of ML TB test were 78.3% and 98.1%, respectively. ML TB test showed similar performance to Xpert MTB/RIF for detection of MTBC and RIF resistance. In addition, ML TB also had good performance for INH resistance detection. Copyright © 2017. Published by Elsevier Ltd.

  18. Supraorbital Postmortem Brain Sampling for Definitive Quantitative Confirmation of Cerebral Sequestration of Plasmodium falciparum Parasites

    PubMed Central

    Milner, Danny A.; Valim, Clarissa; Luo, Robert; Playforth, Krupa B.; Kamiza, Steve; Molyneux, Malcolm E.; Seydel, Karl B.; Taylor, Terrie E.

    2012-01-01

    Background The conventional clinical case definition of cerebral malaria (CM) is imprecise but specificity is improved by a definitive clinical feature such as retinopathy or confirming sequestration of parasites in a post-mortem examination of the brain. A full autopsy is often not possible, since it is costly and may encounter resistance of the deceased's family. Methods We have assessed the use of a cytological smear of brain tissue, obtained post-mortem by supraorbital sampling, for the purpose of quantifying cerebral sequestration in children with fatal malaria in Blantyre, Malawi. We have compared this method to histological quantification of parasites at autopsy. Results The number of parasites present on cytological smears correlated with the proportion of vessels parasitized as assessed by histology of fixed and stained brain tissue. Use of cytological results in addition to the standard clinical case definition increases the specificity of the clinical case definition alone from 48.3% to 100% with a minimal change in sensitivity. Conclusions Post-mortem supraorbital sampling of brain tissue improves the specificity of the diagnosis of fatal cerebral malaria and provides accurate quantitative estimates of cerebral sequestration. This tool can be of great value in clinical, pathogenetic, and epidemiological research studies on cerebral malaria. PMID:22291197

  19. Pap Smear Test Prevalence within Three Years (Age 18+) - Small Area Estimates

    Cancer.gov

    For Pap smear test, a woman 18 years of age or older must have reported having at least one Pap smear test in her life. Furthermore, she should have had one within the last three years by the time of interview.

  20. Clinical use of a portable dual microscope system for smartphone (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kurachi, Cristina; Brognara, Gabriel; Gómez-García, Pablo A.; Carbinatto, Fernanda; Silva, Eduardo V.; Lombardi, Wellington; Inada, Natália M.; Bagnato, Vanderlei S.

    2016-03-01

    Cervical cancer is still one of the most relevant women cancer types, since the 5-year survival rate is of only around 68%. Prevention and early diagnosis are the best strategies to improve cervical cancer prognosis. Conventional diagnosis procedure in Gynecology is mainly based on the macroscopic clinical evaluation, Pap smear cytology, and biopsy, if needed. A portable microscope with dual configuration and its use for diagnosis in Gynecology is investigated. The microscope has interchangeable parts that allow its use for cytopathology smear samples or in situ endoscopic tissue interrogation, both using acriflavine as a nuclei marker. Patients of the Women Ambulatory of the School of Medicine (UNIARA, Araraquara, Brazil) were interrogated during the colposcopy examination. The cervix was initially cleaned using an acetic acid solution, and a 0.05% (wt/vol) acriflavine in saline solution was topically applied at the tissue surface using a cotton swab. Microendoscopy images were taken from clinically normal cervix mucosa and from detected lesions. An image processing is performed to evaluate the cell nuclei morphology and the cytoplasm/nuclei ratio. The Pap smear results and the histology analyses are taken as gold standard for the diagnosis. Preliminary results in 5 patients demonstrated the potential use of our microscope at the clinical setting.

  1. Cervical neoplasia and human papilloma virus infection in prostitutes.

    PubMed

    Gitsch, G; Kainz, C; Reinthaller, A; Kopp, W; Tatra, G; Breitenecker, G

    1991-12-01

    To evaluate the prevalence and incidence of PAP smears indicating cervical dysplasia as well as human papillomavirus (HPV) infection in prostitutes. Prevalence and incidence study of cervical dysplasia and HPV infection in prostitutes. For detection and typing of HPV-DNA In Situ Hybridisation (ISH) was performed in tissue samples with CIN gained by colposcopically directed punch biopsies. Second Department of Obstetrics and Gynecology, University of Vienna Medical School and STD Clinic of the Public Health Office, Vienna. Registered prostitutes attending the STD Clinic of the Public Health Office and a control group. 978 prostitutes and 5493 women with unknown cytological anamnesis were compared. Frequency of positive PAP smears was significantly higher in prostitutes (6.13% versus 1.43%). To determine the pick-up rate of cervical dysplasia during one year after negative cytology we compared 722 prostitutes and 3162 controls. Prostitutes showed a significant higher dysplasia pick-up rate (3.05% to 1.07%) compared with controls. HPV detection rate in prostitutes was similar to that in the control group. The distribution of HPV types revealed a higher frequency of "high risk" HPV 16/18 and 31/33 in prostitutes. The results demonstrate a higher incidence and prevalence of cervical dysplasia in prostitutes and therefore suggest regular cervical PAP smear screening in registered prostitutes twice a year.

  2. Actinomyces-like organisms in the cervical smears of IUCD users.

    PubMed

    Farida Jamal; Mohd Salleh Mohd Yasin; Zooraidah Zainal; Hamid Arshat

    1983-01-01

    Pelvic inflammatory disease (PID) is a well-documented complication of IUD use. The presence of tails on the IUDs appears to facilitate ascent of bacteria from the vagina into the uterus. In this study, cervical smears of 128 IUD users were stained by Gram's stain and screened for the presence of Actinomyces-like organisms. 5.5% of the smears were positive for these organisms. Pus was seen in 20.1% of the smears, and yeast cells were seen in 10.2%. The average duration of IUD insertion was 8 months. Smears of 103 controls were negative for Actinomyces-like organisms, pus cells were present in 8.7%, and yeast cells in 4.8%. Of the 7 smears positive for the organisms, only 1 was from the user of a plastic device. All cases included were asymptomatic and were visiting the clinic for routine follow-up. These data suggest that colonization by Actinomyces-like organisms does not appear to be a significant problem in IUD users in Malaysia.

  3. ρ resonance from the I = 1 ππ potential in lattice QCD

    NASA Astrophysics Data System (ADS)

    Kawai, Daisuke

    2018-03-01

    We calculate the phase shift for the I = 1 ππ scattering in 2+1 flavor lattice QCD at mπ = 410 MeV, using all-to-all propagators with the LapH smearing. We first investigate the sink operator independence of the I = 2 ππ scattering phase shift to estimate the systematics in the LapH smearing scheme in the HAL QCD method at mπ = 870 MeV. The difference in the scattering phase shift in this channel between the conventional point sink scheme and the smeared sink scheme is reasonably small as long as the next-toleading analysis is employed in the smeared sink scheme with larger smearing levels. We then extract the I = 1 ππ potential with the smeared sink operator, whose scattering phase shift shows a resonant behavior (ρ resonance). We also examine the pole of the S-matrix corresponding to the ρ resonance in the complex energy plane.

  4. Microscopic diagnosis of vulvovaginal candidiasis in stained vaginal smears by Dutch general practitioners.

    PubMed

    Engberts, Marian K; Goedbloed, Annelize F; van Haaften, Maarten; van Haaften, Mathilde; Boon, Mathilde E; Boon, Maarten E; Heintz, Peter M

    2007-01-01

    To determine the accuracy of the microscopic diagnosis of vulvovaginal candidiasis (presence of [pseudo] hyphae and blastospores) in stained vaginal smears in clinical practice. General practitioners trained in diagnosing vulvovaginal candidiasis performed microscopy of 324 stained vaginal smears. These smears were sent to the pathologist for confirmation of the microscopic diagnosis of the clinician; cytologic diagnosis by the pathologist was considered the gold standard. In 104 of the 342 cases Candida was established by the pathologist. The clinicians made 24 false positive and 50 false negative diagnoses of Candida. Sensitivity and specificity of the microscopic diagnoses of the clinicians were 52% and 89%, respectively. The most frequent reason for a false positive diagnosis was presence of hairs, whereas the most frequent reason for a false negative diagnosis was understaining of the smear. This study shows that even in stained smears it is difficult for clinicians to recognize blastospores and (pseudo)hyphae. Efforts are clearly needed to improve the quality of the clinical diagnosis of vulvovaginal candidiasis.

  5. Plasmodium species differentiation by non-expert on-line volunteers for remote malaria field diagnosis.

    PubMed

    Ortiz-Ruiz, Alejandra; Postigo, María; Gil-Casanova, Sara; Cuadrado, Daniel; Bautista, José M; Rubio, José Miguel; Luengo-Oroz, Miguel; Linares, María

    2018-01-30

    Routine field diagnosis of malaria is a considerable challenge in rural and low resources endemic areas mainly due to lack of personnel, training and sample processing capacity. In addition, differential diagnosis of Plasmodium species has a high level of misdiagnosis. Real time remote microscopical diagnosis through on-line crowdsourcing platforms could be converted into an agile network to support diagnosis-based treatment and malaria control in low resources areas. This study explores whether accurate Plasmodium species identification-a critical step during the diagnosis protocol in order to choose the appropriate medication-is possible through the information provided by non-trained on-line volunteers. 88 volunteers have performed a series of questionnaires over 110 images to differentiate species (Plasmodium falciparum, Plasmodium ovale, Plasmodium vivax, Plasmodium malariae, Plasmodium knowlesi) and parasite staging from thin blood smear images digitalized with a smartphone camera adapted to the ocular of a conventional light microscope. Visual cues evaluated in the surveys include texture and colour, parasite shape and red blood size. On-line volunteers are able to discriminate Plasmodium species (P. falciparum, P. malariae, P. vivax, P. ovale, P. knowlesi) and stages in thin-blood smears according to visual cues observed on digitalized images of parasitized red blood cells. Friendly textual descriptions of the visual cues and specialized malaria terminology is key for volunteers learning and efficiency. On-line volunteers with short-training are able to differentiate malaria parasite species and parasite stages from digitalized thin smears based on simple visual cues (shape, size, texture and colour). While the accuracy of a single on-line expert is far from perfect, a single parasite classification obtained by combining the opinions of multiple on-line volunteers over the same smear, could improve accuracy and reliability of Plasmodium species identification in remote malaria diagnosis.

  6. Effect of Duration of Irrigation with Sodium Hypochlorite in Clinical Protocol of MTAD on Removal of Smear Layer and Creating Dentinal Erosion

    PubMed Central

    Lotfi, Mehrdad; Moghaddam, Negar; Vosoughhosseini, Sepideh; Zand, Vahid; Saghiri, Mohammad Ali

    2012-01-01

    Background and aims The aim of the present study was to compare 1.3% sodium hypochlorite (NaOCl) in MTAD (mixture of tetracycline isomer, acid, and detergent) for the removal of the smear layer and induction of canal erosion. Materials and methods 38 maxillary incisors were divided in three experimental groups of 10 and two positive and negative control groups of each 4 teeth, and prepared using rotary files. In test groups, 1.3% NaOCl was used for 5, 10 and 20 minutes during preparation followed by MTAD as the final rinse. In negative control group, 5.25% NaOCl was used for 10 minutes followed by 17% Ethylenediamine Tetra-Acetic Acid (EDTA) as the final rinse. In positive control group, dis-tilled water was used for 10 minutes during preparation and then as the final rinse. The samples were examined under scan-ning electron microscope, and the smear layer and dentinal erosion scores were recorded. Results Five and 10 min groups had significant differences with 20 min group (p < 0.05). In apical third, 5 and 10 min groups had also significant differences with 20 min (p < 0.05). In the coronal thirds, when the time of irrigation with 1.3% NaOCl increased from 5 min to 20 min, erosion also increased significantly. However, 5 and 10 min groups had no signifi-cant differences with negative control group. Conclusion The use of 1.3% sodium hypochlorite for 5 and 10 minutes in the MTAD protocol removes the smear layer in the coronal and middle thirds but does not induce erosion. PMID:22991642

  7. [Accuracy of three methods for the rapid diagnosis of oral candidiasis].

    PubMed

    Lyu, X; Zhao, C; Yan, Z M; Hua, H

    2016-10-09

    Objective: To explore a simple, rapid and efficient method for the diagnosis of oral candidiasis in clinical practice. Methods: Totally 124 consecutive patients with suspected oral candidiasis were enrolled from Department of Oral Medicine, Peking University School and Hospital of Stomatology, Beijing, China. Exfoliated cells of oral mucosa and saliva or concentrated oral rinse) obtained from all participants were tested by three rapid smear methods(10% KOH smear, gram-stained smear, Congo red stained smear). The diagnostic efficacy(sensitivity, specificity, Youden's index, likelihood ratio, consistency, predictive value and area under curve(AUC) of each of the above mentioned three methods was assessed by comparing the results with the gold standard(combination of clinical diagnosis, laboratory diagnosis and expert opinion). Results: Gram-stained smear of saliva(or concentrated oral rinse) demonstrated highest sensitivity(82.3%). Test of 10%KOH smear of exfoliated cells showed highest specificity(93.5%). Congo red stained smear of saliva(or concentrated oral rinse) displayed highest diagnostic efficacy(79.0% sensitivity, 80.6% specificity, 0.60 Youden's index, 4.08 positive likelihood ratio, 0.26 negative likelihood ratio, 80% consistency, 80.3% positive predictive value, 79.4% negative predictive value and 0.80 AUC). Conclusions: Test of Congo red stained smear of saliva(or concentrated oral rinse) could be used as a point-of-care tool for the rapid diagnosis of oral candidiasis in clinical practice. Trial registration: Chinese Clinical Trial Registry, ChiCTR-DDD-16008118.

  8. Cost-benefit analysis of Xpert MTB/RIF for tuberculosis suspects in German hospitals.

    PubMed

    Diel, Roland; Nienhaus, Albert; Hillemann, Doris; Richter, Elvira

    2016-02-01

    Our objective was to assess the cost-benefit of enhancing or replacing the conventional sputum smear with the real-time PCR Xpert MTB/RIF method in the inpatient diagnostic schema for tuberculosis (TB).Recent data from published per-case cost studies for TB/multidrug-resistant (MDR)-TB and from comparative analyses of sputum microscopy, mycobacterial culture, Xpert MTB/RIF and drug susceptibility testing, performed at the German National Reference Center for Mycobacteria, were used. Potential cost savings of Xpert MTB/RIF, based on test accuracy and multiple cost drivers, were calculated for diagnosing TB/MDR-TB suspects from the hospital perspective.Implementing Xpert MTB/RIF as an add-on in smear-positive and smear-negative TB suspects saves on average €48.72 and €503, respectively, per admitted patient as compared with the conventional approach. In smear-positive and smear-negative MDR-TB suspects, cost savings amount to €189.56 and €515.25 per person, respectively. Full replacement of microscopy by Xpert MTB/RIF saves €449.98. In probabilistic Monte-Carlo simulation, adding Xpert MTB/RIF is less costly in 46.4% and 76.2% of smear-positive TB and MDR-TB suspects, respectively, but 100% less expensive in all smear-negative suspects. Full replacement by Xpert MTB/RIF is also consistently cost-saving.Using Xpert MTB/RIF as an add-on to and even as a replacement for sputum smear examination may significantly reduce expenditures in TB suspects. Copyright ©ERS 2016.

  9. Identification of mycobacterium tuberculosis in sputum smear slide using automatic scanning microscope

    NASA Astrophysics Data System (ADS)

    Rulaningtyas, Riries; Suksmono, Andriyan B.; Mengko, Tati L. R.; Saptawati, Putri

    2015-04-01

    Sputum smear observation has an important role in tuberculosis (TB) disease diagnosis, because it needs accurate identification to avoid high errors diagnosis. In development countries, sputum smear slide observation is commonly done with conventional light microscope from Ziehl-Neelsen stained tissue and it doesn't need high cost to maintain the microscope. The clinicians do manual screening process for sputum smear slide which is time consuming and needs highly training to detect the presence of TB bacilli (mycobacterium tuberculosis) accurately, especially for negative slide and slide with less number of TB bacilli. For helping the clinicians, we propose automatic scanning microscope with automatic identification of TB bacilli. The designed system modified the field movement of light microscope with stepper motor which was controlled by microcontroller. Every sputum smear field was captured by camera. After that some image processing techniques were done for the sputum smear images. The color threshold was used for background subtraction with hue canal in HSV color space. Sobel edge detection algorithm was used for TB bacilli image segmentation. We used feature extraction based on shape for bacilli analyzing and then neural network classified TB bacilli or not. The results indicated identification of TB bacilli that we have done worked well and detected TB bacilli accurately in sputum smear slide with normal staining, but not worked well in over staining and less staining tissue slide. However, overall the designed system can help the clinicians in sputum smear observation becomes more easily.

  10. Local spatial variations analysis of smear-positive tuberculosis in Xinjiang using Geographically Weighted Regression model.

    PubMed

    Wei, Wang; Yuan-Yuan, Jin; Ci, Yan; Ahan, Alayi; Ming-Qin, Cao

    2016-10-06

    The spatial interplay between socioeconomic factors and tuberculosis (TB) cases contributes to the understanding of regional tuberculosis burdens. Historically, local Poisson Geographically Weighted Regression (GWR) has allowed for the identification of the geographic disparities of TB cases and their relevant socioeconomic determinants, thereby forecasting local regression coefficients for the relations between the incidence of TB and its socioeconomic determinants. Therefore, the aims of this study were to: (1) identify the socioeconomic determinants of geographic disparities of smear positive TB in Xinjiang, China (2) confirm if the incidence of smear positive TB and its associated socioeconomic determinants demonstrate spatial variability (3) compare the performance of two main models: one is Ordinary Least Square Regression (OLS), and the other local GWR model. Reported smear-positive TB cases in Xinjiang were extracted from the TB surveillance system database during 2004-2010. The average number of smear-positive TB cases notified in Xinjiang was collected from 98 districts/counties. The population density (POPden), proportion of minorities (PROmin), number of infectious disease network reporting agencies (NUMagen), proportion of agricultural population (PROagr), and per capita annual gross domestic product (per capita GDP) were gathered from the Xinjiang Statistical Yearbook covering a period from 2004 to 2010. The OLS model and GWR model were then utilized to investigate socioeconomic determinants of smear-positive TB cases. Geoda 1.6.7, and GWR 4.0 software were used for data analysis. Our findings indicate that the relations between the average number of smear-positive TB cases notified in Xinjiang and their socioeconomic determinants (POPden, PROmin, NUMagen, PROagr, and per capita GDP) were significantly spatially non-stationary. This means that in some areas more smear-positive TB cases could be related to higher socioeconomic determinant regression coefficients, but in some areas more smear-positive TB cases were found to do with lower socioeconomic determinant regression coefficients. We also found out that the GWR model could be better exploited to geographically differentiate the relationships between the average number of smear-positive TB cases and their socioeconomic determinants, which could interpret the dataset better (adjusted R 2  = 0.912, AICc = 1107.22) than the OLS model (adjusted R 2  = 0.768, AICc = 1196.74). POPden, PROmin, NUMagen, PROagr, and per capita GDP are socioeconomic determinants of smear-positive TB cases. Comprehending the spatial heterogeneity of POPden, PROmin, NUMagen, PROagr, per capita GDP, and smear-positive TB cases could provide valuable information for TB precaution and control strategies.

  11. Drug resistance of Mycobacterium tuberculosis in Malawi: a cross-sectional survey

    PubMed Central

    Abouyannis, Michael; Dacombe, Russell; Dambe, Isaias; Mpunga, James; Faragher, Brian; Gausi, Francis; Ndhlovu, Henry; Kachiza, Chifundo; Suarez, Pedro; Mundy, Catherine; Banda, Hastings T; Nyasulu, Ishmael

    2014-01-01

    Abstract Objective To document the prevalence of multidrug resistance among people newly diagnosed with – and those retreated for – tuberculosis in Malawi. Methods We conducted a nationally representative survey of people with sputum-smear-positive tuberculosis between 2010 and 2011. For all consenting participants, we collected demographic and clinical data, two sputum samples and tested for human immunodeficiency virus (HIV).The samples underwent resistance testing at the Central Reference Laboratory in Lilongwe, Malawi. All Mycobacterium tuberculosis isolates found to be multidrug-resistant were retested for resistance to first-line drugs – and tested for resistance to second-line drugs – at a Supranational Tuberculosis Reference Laboratory in South Africa. Findings Overall, M. tuberculosis was isolated from 1777 (83.8%) of the 2120 smear-positive tuberculosis patients. Multidrug resistance was identified in five (0.4%) of 1196 isolates from new cases and 28 (4.8%) of 581 isolates from people undergoing retreatment. Of the 31 isolates from retreatment cases who had previously failed treatment, nine (29.0%) showed multidrug resistance. Although resistance to second-line drugs was found, no cases of extensive drug-resistant tuberculosis were detected. HIV testing of people from whom M. tuberculosis isolates were obtained showed that 577 (48.2%) of people newly diagnosed and 386 (66.4%) of people undergoing retreatment were positive. Conclusion The prevalence of multidrug resistance among people with smear-positive tuberculosis was low for sub-Saharan Africa – probably reflecting the strength of Malawi’s tuberculosis control programme. The relatively high prevalence of such resistance observed among those with previous treatment failure may highlight a need for a change in the national policy for retreating this subgroup of people with tuberculosis. PMID:25378741

  12. Rapid Detection of Mycobacterium tuberculosis and Rifampin Resistance by Use of On-Demand, Near-Patient Technology▿ † ‡

    PubMed Central

    Helb, Danica; Jones, Martin; Story, Elizabeth; Boehme, Catharina; Wallace, Ellen; Ho, Ken; Kop, JoAnn; Owens, Michelle R.; Rodgers, Richard; Banada, Padmapriya; Safi, Hassan; Blakemore, Robert; Lan, N. T. Ngoc; Jones-López, Edward C.; Levi, Michael; Burday, Michele; Ayakaka, Irene; Mugerwa, Roy D.; McMillan, Bill; Winn-Deen, Emily; Christel, Lee; Dailey, Peter; Perkins, Mark D.; Persing, David H.; Alland, David

    2010-01-01

    Current nucleic acid amplification methods to detect Mycobacterium tuberculosis are complex, labor-intensive, and technically challenging. We developed and performed the first analysis of the Cepheid Gene Xpert System's MTB/RIF assay, an integrated hands-free sputum-processing and real-time PCR system with rapid on-demand, near-patient technology, to simultaneously detect M. tuberculosis and rifampin resistance. Analytic tests of M. tuberculosis DNA demonstrated a limit of detection (LOD) of 4.5 genomes per reaction. Studies using sputum spiked with known numbers of M. tuberculosis CFU predicted a clinical LOD of 131 CFU/ml. Killing studies showed that the assay's buffer decreased M. tuberculosis viability by at least 8 logs, substantially reducing biohazards. Tests of 23 different commonly occurring rifampin resistance mutations demonstrated that all 23 (100%) would be identified as rifampin resistant. An analysis of 20 nontuberculosis mycobacteria species confirmed high assay specificity. A small clinical validation study of 107 clinical sputum samples from suspected tuberculosis cases in Vietnam detected 29/29 (100%) smear-positive culture-positive cases and 33/39 (84.6%) or 38/53 (71.7%) smear-negative culture-positive cases, as determined by growth on solid medium or on both solid and liquid media, respectively. M. tuberculosis was not detected in 25/25 (100%) of the culture-negative samples. A study of 64 smear-positive culture-positive sputa from retreatment tuberculosis cases in Uganda detected 63/64 (98.4%) culture-positive cases and 9/9 (100%) cases of rifampin resistance. Rifampin resistance was excluded in 54/55 (98.2%) susceptible cases. Specificity rose to 100% after correcting for a conventional susceptibility test error. In conclusion, this highly sensitive and simple-to-use system can detect M. tuberculosis directly from sputum in less than 2 h. PMID:19864480

  13. Prevalence of Anaplasma phagocytophilum infection in feral cats in Massachusetts

    PubMed Central

    Galemore, Erin R; Labato, Mary A; O’Neil, Elizabeth

    2018-01-01

    Objectives The primary objective of this study was to determine the prevalence of Anaplasma phagocytophilum infection and exposure in adult feral cats in Massachusetts, an endemic area for A phagocytophilum and its tick vector Ixodes scapularis. The secondary objective was to determine if there were correlations between A phagocytophilum infection and the presence of anemia and thrombocytopenia. Methods Blood samples were collected between June and December 2015 from 175 apparently healthy adult feral cats that were presented to trap and release spay/neuter centers in Massachusetts. Complete blood count, blood smear evaluation, SNAP 4Dx Plus test (IDEXX) and A phagocytophilum PCR were performed on all samples to document acute infection (PCR-positive and/or inclusions observed on blood smear) and exposure to A phagocytophilum (SNAP 4Dx Plus-positive for A phagocytophilum antibodies). Results The prevalence of exposure to A phagocytophilum in feral cats in Massachusetts was 9.7%, whereas the prevalence of acute infection was 6.9%. All blood smears were negative for Anaplasma species inclusions; therefore, acute infection was defined as testing positive on PCR analysis. No statistically significant correlations were identified for cats that were positive for A phagocytophilum on PCR analysis or SNAP 4Dx Plus test and the presence of anemia or thrombocytopenia. Conclusions and relevance The prevalence of A phagocytophilum exposure in feral cats approaches 10% and is higher than the previously reported national average prevalence of 4.3% in the USA. A phagocytophilum infection may be an emerging infectious disease in cats. Further research is needed to determine the prevalence of clinical illness associated with A phagocytophilum infection in cats living in endemic areas. PMID:29399369

  14. Evaluation of Xpert MTB/RIF assay in children with presumed pulmonary tuberculosis in Papua New Guinea.

    PubMed

    Kasa Tom, Sharon; Welch, Henry; Kilalang, Cornelia; Tefuarani, Nakapi; Vince, John; Lavu, Evelyn; Johnson, Karen; Magaye, Ruth; Duke, Trevor

    2018-05-01

    The Gene Xpert MTB/ RIF assay (Xpert) is used for rapid, simultaneous detection of Mycobacterium tuberculosis (MTB) and rifampicin resistance. This study examined the accuracy of Xpert in children with suspected pulmonary tuberculosis (PTB). Children admitted to Port Moresby General Hospital with suspected PTB were prospectively enrolled between September 2014 and March 2015. They were classified into probable, possible and TB-unlikely groups. Sputum or gastric aspirates were tested by Xpert and smear microscopy; mycobacterial culture was undertaken on a subset. Children were diagnosed with TB on the basis of standard criteria which were used as the primary reference standard. Xpert, smear for acid-fast bacilli (AFB) and the Edwards TB score were compared with the primary reference standard. A total of 93 children ≤14 years with suspected PTB were enrolled; 67 (72%) were classified as probable, 21 (22%) possible and 5 (5.4%) TB-unlikely. Eighty were treated for TB based on the primary reference standard. Xpert was positive in 26/93 (28%) MTB cases overall, including 22/67 (33%) with probable TB and 4/21 (19%) with possible TB. Three (13%) samples identified rifampicin resistance. Xpert confirmed more cases of TB than AFB smear (26 vs 13, p = 0.019). The sensitivity of Xpert, AFB smear and an Edwards TB score of ≥7 was 31% (25/80), 16% (13/80) and 90% (72/80), respectively, and the specificity was 92% (12/13), 100% (13/13) and 31% (4/13), respectively, when compared with the primary reference standard. Xpert sensitivity is sub-optimal and cannot be relied upon for diagnosing TB, although a positive result is confirmatory. A detailed history and examination, standardised clinical criteria, radiographs and available tests remain the most appropriate way of diagnosing TB in children in resource-limited countries. Xpert helps confirm PTB better than AFB smear, and identifies rifampicin resistance. Practical guidelines should be used to identify children who will benefit from an Xpert assay.

  15. Effect of Peracetic Acid as A Final Rinse on Push Out Bond Strength of Root Canal Sealers to Root Dentin.

    PubMed

    Gaddala, Naresh; Veeramachineni, Chandrasekhar; Tummala, Muralidhar

    2015-05-01

    Smear layer which was formed during the instrumentation of root canals hinders the penetration of root canal sealers to root dentin and affect the bond strength of root canal sealers to root dentin. Final irrigant such as demineralizing agents are used to remove the inorganic portion of the smear layer. In the present study, peracetic acid used as a final rinse, to effect the bond strength of root canal sealers to root dentin. The purpose of the present study was to evaluate the efficacy of peracetic acid as a final irrigant on bond strength of root canal sealers to root dentin. Sixty six freshly extracted human single rooted mandibular premolars were used for this study. After decoronation the samples were instrumented with Protaper upto F3 and irrigated with 5.25% NaOcl. The teeth were then divided into three groups based on final irrigant used: Group-1(control group) Canals were irrigated with distilled water. Group-2: Canals were irrigated with peracetic acid. Group-3: Canals were irrigated with smear clear. Each group was further divided into three subgroups (n=30) based on the sealer used to obturate the canals. Subgroup-1: kerr, Subgroup-2: Apexit plus, Subgroup-3: AH PLUS. Each sealer was mixed and coated to master cone and placed in the canal. The bonding between sealer and dentin surface was evaluated using push out bond strength by universal testing machine. The mean bond strength values of each group were statistically evaluated using Two-way ANOVA followed by Tukey post-hoc test. Significant difference was found among the bond strength of the sealers. But, there is no statistically significant difference between the groups irrigated with peracetic acid and smear clear compared to control group. AH Plus showed highest bond strength irrespective of the final irrigant used. Peracetic acid when employed as final irrigant improved the bond strength of root canal sealers compared to control group but not statistically significant than smear clear.

  16. GeneXpert MTB/RIF Assay for the Diagnosis of Tuberculous Lymphadenitis on Concentrated Fine Needle Aspirates in High Tuberculosis Burden Settings.

    PubMed

    Tadesse, Mulualem; Abebe, Gemeda; Abdissa, Ketema; Aragaw, Dossegnaw; Abdella, Kedir; Bekele, Alemayehu; Bezabih, Mesele; Apers, Ludwig; de Jong, Bouke C; Rigouts, Leen

    2015-01-01

    The diagnosis of tuberculous lymphadenitis (TBL) remains challenging. The routinely used methods (cytology and smear microscopy) have sub-optimal sensitivity. Recently, WHO recommends GeneXpert to be used as the initial diagnostic test in patients suspected of having extra-pulmonary tuberculosis (EPTB). However, this was a conditional recommendation due to very low-quality evidence available and more studies are needed. In this study we evaluated the performance of Xpert for the diagnosis of TBL on concentrated fine needle aspirates (FNA) in Southwest Ethiopia. FNA was collected from presumptive TBL cases. Two smears were prepared from each aspirate and processed for cytology and conventional microscopy. The remaining aspirate was treated with N-acetyl-L-cysteine-NaOH and centrifuged for 15minutes at 3000g. The concentrated sediment was used for culture and Xpert test. Capilia TB-Neo test was used to differentiate M. tuberculosis complex (MTBC) from non-tuberculous mycobacteria (NTM). Composite bacteriological methods (culture and/or smear microscopy) were considered as a reference standard. Out of 143 enrolled suspects, 64.3% (92/143) were confirmed TBL cases by the composite reference standard (CRS). Xpert detected M. tuberculosis complex (MTBC) in 60.1% (86/143) of the presumptive TBL cases. The sensitivity of Xpert compared to CRS was 87.8% [95% CI: 81.0-94.5] and specificity 91.1% [95% CI: 82.8-99.4]. The sensitivity was 27.8% for smear microscopy and 80% for cytology compared to CRS. Cytology showed the lowest specificity (57.8%). Xpert was positive in 4 out of 45 culture- and smear-negative cases. Among 47 cytomorphologically non-TBL cases, 15 were positive on Xpert. More than half of Xpert-positive cases were in the range of very low cut-off threshold values (28

  17. Effect of Peracetic Acid as A Final Rinse on Push Out Bond Strength of Root Canal Sealers to Root Dentin

    PubMed Central

    Gaddala, Naresh; Veeramachineni, Chandrasekhar

    2015-01-01

    Background Smear layer which was formed during the instrumentation of root canals hinders the penetration of root canal sealers to root dentin and affect the bond strength of root canal sealers to root dentin. Final irrigant such as demineralizing agents are used to remove the inorganic portion of the smear layer. In the present study, peracetic acid used as a final rinse, to effect the bond strength of root canal sealers to root dentin. Aim The purpose of the present study was to evaluate the efficacy of peracetic acid as a final irrigant on bond strength of root canal sealers to root dentin. Materials and Methods Sixty six freshly extracted human single rooted mandibular premolars were used for this study. After decoronation the samples were instrumented with Protaper upto F3 and irrigated with 5.25% NaOcl. The teeth were then divided into three groups based on final irrigant used: Group-1(control group) Canals were irrigated with distilled water. Group-2: Canals were irrigated with peracetic acid. Group-3: Canals were irrigated with smear clear. Each group was further divided into three subgroups (n=30) based on the sealer used to obturate the canals. Subgroup-1: kerr, Subgroup-2: Apexit plus, Subgroup-3: AH PLUS. Each sealer was mixed and coated to master cone and placed in the canal. The bonding between sealer and dentin surface was evaluated using push out bond strength by universal testing machine. The mean bond strength values of each group were statistically evaluated using Two-way ANOVA followed by Tukey post-hoc test. Results Significant difference was found among the bond strength of the sealers. But, there is no statistically significant difference between the groups irrigated with peracetic acid and smear clear compared to control group. AH Plus showed highest bond strength irrespective of the final irrigant used. Conclusion Peracetic acid when employed as final irrigant improved the bond strength of root canal sealers compared to control group but not statistically significant than smear clear. PMID:26155568

  18. Analytical solution for vacuum preloading considering the nonlinear distribution of horizontal permeability within the smear zone.

    PubMed

    Peng, Jie; He, Xiang; Ye, Hanming

    2015-01-01

    The vacuum preloading is an effective method which is widely used in ground treatment. In consolidation analysis, the soil around prefabricated vertical drain (PVD) is traditionally divided into smear zone and undisturbed zone, both with constant permeability. In reality, the permeability of soil changes continuously within the smear zone. In this study, the horizontal permeability coefficient of soil within the smear zone is described by an exponential function of radial distance. A solution for vacuum preloading consolidation considers the nonlinear distribution of horizontal permeability within the smear zone is presented and compared with previous analytical results as well as a numerical solution, the results show that the presented solution correlates well with the numerical solution, and is more precise than previous analytical solution.

  19. Analytical solution for vacuum preloading considering the nonlinear distribution of horizontal permeability within the smear zone

    PubMed Central

    Peng, Jie; He, Xiang; Ye, Hanming

    2015-01-01

    The vacuum preloading is an effective method which is widely used in ground treatment. In consolidation analysis, the soil around prefabricated vertical drain (PVD) is traditionally divided into smear zone and undisturbed zone, both with constant permeability. In reality, the permeability of soil changes continuously within the smear zone. In this study, the horizontal permeability coefficient of soil within the smear zone is described by an exponential function of radial distance. A solution for vacuum preloading consolidation considers the nonlinear distribution of horizontal permeability within the smear zone is presented and compared with previous analytical results as well as a numerical solution, the results show that the presented solution correlates well with the numerical solution, and is more precise than previous analytical solution. PMID:26447973

  20. The Sensitivity and Specificity of Potassium Hydroxide Smear and Fungal Culture Relative to Clinical Assessment in the Evaluation of Tinea Pedis: A Pooled Analysis

    PubMed Central

    Levitt, Jacob Oren; Levitt, Barrie H.; Akhavan, Arash; Yanofsky, Howard

    2010-01-01

    Background. There are relatively few studies published examining the sensitivity and specificity of potassium hydroxide (KOH) smear and fungal culture examination of tinea pedis. Objective. To evaluate the sensitivity and specificity of KOH smear and fungal culture for diagnosing tinea pedis. Methods. A pooled analysis of data from five similarly conducted bioequivalence trials for antifungal drugs was performed. Data from 460 patients enrolled in the vehicle arms of these studies with clinical diagnosis of tinea pedis supported by positive fungal culture were analyzed 6 weeks after initiation of the study to determine the sensitivity and specificity of KOH smear and fungal culture. Results. Using clinical assessment as the gold standard, the sensitivities for KOH smear and culture were 73.3% (95% CI: 66.3 to 79.5%) and 41.7% (34.6 to 49.1%), respectively. The respective specificities for culture and KOH smear were 77.7% (72.2 to 82.5%) and 42.5% (36.6 to 48.6%). Conclusion. KOH smear and fungal culture are complementary diagnostic tests for tinea pedis, with the former being the more sensitive test of the two, and the latter being more specific. PMID:20672004

  1. Inflammation on the Cervical Papanicolaou Smear: Evidence for Infection in Asymptomatic Women?

    PubMed Central

    Tsirmpa, Ioanna; Chasiakou, Anthia; Tsouma, Iliana; Politi, Ekaterina; Gennimata, Vassiliki; Kouskouni, Evangelia

    2013-01-01

    Background. The significance of the possible presence of infection on the Pap smear of asymptomatic women based on cytological criteria is practically unknown. Materials and Methods. A total of 1117 asymptomatic nonpregnant women had Pap smear tests and vaginal as well as cervical cultures completed (622 with and 495 without inflammation on the Pap smear). Results. Out of the 622 women with inflammation on Pap test, 251 (40.4%) had negative cultures (normal flora present), while 371 (59.6%) women had positive cultures with different pathogens. In contrast, the group of women without inflammation on Pap test displayed significantly increased percentage of negative cultures (67.1%, P < 0.001) and decreased percentage of positive cultures (32.9%, P < 0.001). Bacterial vaginosis was diagnosed more frequently in both groups and significantly more in the group with inflammation on Pap smear compared to the group without inflammation (P < 0.02). Conclusions. A report of inflammatory changes on the cervical Pap smear cannot be used to reliably predict the presence of a genital tract infection, especially in asymptomatic women. Nevertheless, the isolation of different pathogens in about 60% of the women with inflammation on the Pap smear cannot be overlooked and must be regarded with concern. PMID:24204103

  2. Cervical cancer screening after 50: near extinction?

    PubMed

    Abdullah, Nik N; Daud, Suzanna; Al-Kubaisy, Waqar; Saari, Izni S; Saad, Siti R

    2016-11-01

    The objectives of this study were to determine the prevalence and predictors of Pap smear screening among women aged 50 years and older. This cross-sectional study was conducted at two large urban health centres in Selangor. A total of 515 women aged 50 and older were recruited. The mean age of the respondents was 58.83±7.05, with a range of 50- 83 years. The prevalence of Pap smear screening was 39.22% (n=202). From the multivariate analysis, Pap smear screening was significantly associated with health care provider advice (adjusted odds ratio (AOR)=18.75; 95% CI=8.30, 42.37); tertiary (AOR=11.26; 95% CI=1.50, 84.68) and secondary education level (AOR=9.47; 95% CI=1.43, 62.84); use of contraception (AOR=2.90; 95% CI=1.48, 5.69); heart disease (AOR=0.22; 95% CI=0.05, 0.97); and worry about Pap smear results (AOR=0.20; 95% CI=0.09, 0.42). The prevalence of Pap smear screening in the older women is unsatisfactory. Health care provider advice, education level, use of contraception, heart disease and worry about Pap smear results were predictors of undergoing Pap smear screening in this study population. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Evaluation of the ICT Tuberculosis test for the routine diagnosis of tuberculosis

    PubMed Central

    Ongut, Gozde; Ogunc, Dilara; Gunseren, Filiz; Ogus, Candan; Donmez, Levent; Colak, Dilek; Gultekin, Meral

    2006-01-01

    Background Rapid and accurate diagnosis of tuberculosis (TB) is crucial to facilitate early treatment of infectious cases and thus to reduce its spread. To improve the diagnosis of TB, more rapid diagnostic techniques such as antibody detection methods including enzyme-linked immunosorbent assay (ELISA)-based serological tests and immunochromatographic methods were developed. This study was designed to evaluate the validity of an immunochromatographic assay, ICT Tuberculosis test for the serologic diagnosis of TB in Antalya, Turkey. Methods Sera from 72 patients with active pulmonary (53 smear-positive and 19 smear-negative cases) and eight extrapulmonary (6 smear-positive and 2 smear-negative cases) TB, and 54 controls from different outpatient clinics with similar demographic characteristics as patients were tested by ICT Tuberculosis test. Results The sensitivity, specificity, and negative predictive value of the ICT Tuberculosis test for pulmonary TB were 33.3%, 100%, and 52.9%, respectively. Smear-positive pulmonary TB patients showed a higher positivity rate for antibodies than smear-negative patients, but the difference was not statistically significant. Of the eight patients with extrapulmonary TB, antibody was detected in four patients. Conclusion Our results suggest that ICT Tuberculosis test can be used to aid TB diagnosis in smear-positive patients until the culture results are available. PMID:16504161

  4. Inflammatory events as detected in cervical smears and squamous intraepithelial lesions.

    PubMed

    Roeters, Anne M E; Boon, Mathilde E; van Haaften, Maarten; Vernooij, F; Bontekoe, Tj Romke; Heintz, A Peter M

    2010-02-01

    The Dutch cytological coding system, KOPAC, enables to code for eight inflammatory events, that is koilocytosis (related to human papillomavirus (HPV)), Trichomonas, dysbacteriosis [related to bacterial vaginosis (BV)], Candida, Gardnerella, Actinomyces, Chlamydia, and non-specific inflammation (leucocytosis). This study presents an analysis of 1,008,879 smears. Of each smear, the age of the woman and the reason for smear taking (screening or indication) was available. The cytoscores (per mille) for these codes were calculated. For the screening smears, the cytoscores were for koilocytosis (HPV) 2.6, for Trichomonas vaginalis 1.9, for dysbacteriosis 31.4, for Candida albicans 9.8, for Gardnerella vaginalis 0.7, for Actinomyces 6.9, for Chlamydia 0.8, and for non-specific inflammatory changes 66.4. For the calculation of the Odds Ratio (OR), normal smears were used as a reference. The cytoscores for Chlamydia and Gardnerella covaried with high grade SIL (HSIL), with an OR of 7 and 12, respectively. In addition, the OR for Trichomonas vaginalis, for dysbacteriosis, and for leucocytosis proved to be significantly high in the indication smears. This study provides an oversight of HSIL and the full range of cervical infections as detected by cytology, proving that this infectious byproduct of screening can be very valuable.

  5. Evaluation of Microscopic Observation Drug Susceptibility (MODS) and the string test for rapid diagnosis of pulmonary tuberculosis in HIV/AIDS patients in Bolivia.

    PubMed

    Lora, Meredith H; Reimer-McAtee, Melissa J; Gilman, Robert H; Lozano, Daniel; Saravia, Ruth; Pajuelo, Monica; Bern, Caryn; Castro, Rosario; Espinoza, Magaly; Vallejo, Maya; Solano, Marco; Challapa, Roxana; Torrico, Faustino

    2015-06-06

    Tuberculosis (TB) is the most common opportunistic infection and the leading cause of death in HIV-positive people worldwide. Diagnosing TB is difficult, and is more challenging in resource-scarce settings where culture-based diagnostic methods rely on poorly sensitive smear microscopy by Ziehl-Neelsen stain (ZN). We performed a cross-sectional study examining the diagnostic utility of Microscopic Observation Drug Susceptibility liquid culture (MODS) versus traditional Ziehl-Neelsen staining (ZN) and Lowenstein Jensen culture (LJ) of pulmonary tuberculosis (TB) and multidrug-resistant tuberculosis (MDRTB) in HIV-infected patients in Bolivia. For sputum scarce individuals we assessed the value of the string test and induced sputum for TB diagnosis. The presence of Mycobacterium tuberculosis (Mtb) in the sputum of 107 HIV-positive patients was evaluated by ZN, LJ, and MODS. Gastric secretion samples obtained by the string test were evaluated by MODS in 102 patients. The TB-HIV co-infection rate of HIV patients with respiratory symptoms by sputum sample was 45 % (48/107); 46/48 (96 %) were positive by MODS, 38/48 (79 %) by LJ, and 30/48 (63 %) by ZN. The rate of MDRTB was 9 % (4/48). Median time to positive culture was 10 days by MODS versus 34 days by LJ (p < 0.0001). In smear-negative patients, MODS detected TB in 17/18 patients, compared to 11/18 by LJ (94.4 % vs 61.0 %, p = 0.03 %). In patients unable to produce a sputum sample without induction, the string test cultured by MODS yielded Mtb in of 9/11 (82 %) TB positive patients compared to 11/11 (100 %) with induced sputum. Of the 10 patients unable to produce a sputum sample, 4 were TB-positive by string test. MODS was faster and had a higher Mtb detection yield compared to LJ, with a greater difference in yield between the two in smear-negative patients. The string test is a valuable diagnostic technique for HIV sputum-scarce or sputum-absent patients, and should be considered as an alternative test to induced sputum to obtain sample for Mtb in resource-limited settings. Nine percent of our TB+ patients had MDRTB, which reinforces the need for rapid detection with direct drug susceptibility testing in HIV patients in Bolivia.

  6. A MORE COST-EFFECTIVE EMAP-W BENTHIC MACROFAUNAL SAMPLE UNIT

    EPA Science Inventory

    The standard EPA West Coast Environmental Monitoring and Assessment Program (EMAP-W) benthic macrofaunal sampling protocol is to collect 30-50 random benthic samples per reporting unit (e.g., estuary, region) using a 0.1 m2 grab and to sort out macrofauna using a 1.0 mm mesh scre...

  7. Is self-sampling to test for high-risk papillomavirus an acceptable option among women who have been treated for high-grade cervical intraepithelial neoplasia?

    PubMed

    Andersson, Sonia; Belkić, Karen; Mints, Miriam; Östensson, Ellinor

    2018-01-01

    Self-sampling to test for high risk human papilloma virus (HPV) is becoming an increasingly important component of cervical cancer screening. The aim of this observational study is to examine how women treated for high-grade cervical intraepithelial neoplasia (CIN) view HPV self-sampling. Invited to participate in the present study were patients who had undergone treatment of high-grade CIN (grade 2 or higher) and were followed-up at 6-months at the Karolinska University Hospital, Stockholm. The participants were instructed as to how to perform HPV self-sampling. Thereafter, the participants completed a questionnaire about HPV self-sampling and other cervical cancer screening methods, as well as about self-perceived risk of cervical cancer without regular gynecologic follow-up and about specific knowledge regarding HPV, CIN and cervical cancer. Altogether 479 women enrolled in this study. The participation rate was 96.6%. Nearly 75% of the participants stated they would consider performing the HPV self-sampling prior to their next gynecologic follow-up. Confidence in HPV self-sampling was a significant independent predictor of willingness to perform HPV self-sampling. However, confidence in HPV self-sampling was significantly lower than confidence in Papanicolaou smears and in HPV testing with samples collected by health professionals. Higher specific knowledge about HPV, CIN and cervical cancer was also a significant independent predictor of willingness to perform HPV self-sampling, as was having travelled longer distance to attend gynecologic follow-up. Participants with lower income and without completed university education expressed significantly higher confidence in HPV self-sampling and lower confidence in Papanicolaou smears than the other women. To the best of our knowledge, this is the first study to examine the views of women treated for high-grade CIN vis-à-vis HPV self-sampling. The latter is an acceptable option for the vast majority of this cohort of women.

  8. Analysis of 13 million individual patient records pertaining to Pap smears, colposcopies, biopsies and surgery on the uterine cervix (Belgium, 1996-2000).

    PubMed

    Arbyn, Marc; Simoens, Cindy; Van Oyen, Herman; Foidart, Jean-Michel; Goffin, Frédéric; Simon, Philippe; Fabri, Valérie

    2009-05-01

    Cervical cancer screening by surveys overestimate coverage because of selection and reporting biases. The prepared Inter-Mutualistic Agency dataset has about 13 million records from Pap smears, colposcopies, cervical biopsies and surgery, performed in Belgium between 1996 and 2000. Cervical cancer screening coverage was defined as the proportion of the target population (women of 25-64 years) that has had a Pap smear taken within the last 3 years. Proportions and incidence rates were computed using official population data of the corresponding age group, area and calendar year. Cervical cancer screening coverage, in the period 1998-2000, was 59% at national level, for the target age group 25-64 years. Differences were small between the 3 regions. Variation ranged from 39% to 71%. Coverage was 64% for 25-29 year old women, 67% for those aged 30-39 years, 56% for those aged 50-54. The modal screening interval was 1 year. In the 3-year period 1998-2000, 3 million smears were taken from the 2.7 million women in the age group 25-64. Only 1.6 million women of the target group got one or more smears in that period and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman. Coverage reached only 59%, but the number of smears used was sufficient to cover more than 100% of the target population. Structural reduction of overuse and extension of coverage is warranted.

  9. Portable smartphone based quantitative phase microscope

    NASA Astrophysics Data System (ADS)

    Meng, Xin; Tian, Xiaolin; Yu, Wei; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2018-01-01

    To realize portable device with high contrast imaging capability, we designed a quantitative phase microscope using transport of intensity equation method based on a smartphone. The whole system employs an objective and an eyepiece as imaging system and a cost-effective LED as illumination source. A 3-D printed cradle is used to align these components. Images of different focal planes are captured by manual focusing, followed by calculation of sample phase via a self-developed Android application. To validate its accuracy, we first tested the device by measuring a random phase plate with known phases, and then red blood cell smear, Pap smear, broad bean epidermis sections and monocot root were also measured to show its performance. Owing to its advantages as accuracy, high-contrast, cost-effective and portability, the portable smartphone based quantitative phase microscope is a promising tool which can be future adopted in remote healthcare and medical diagnosis.

  10. Fragmentation of Red Blood Cells Caused Pseudothrombocytosis in a Patient.

    PubMed

    Tang, Wenjun; Tang, Chunhua; Zheng, Jianfeng; He, Yongling; Lu, Fangfang

    2018-06-01

    Pseudothrombocytopenia, caused by platelet (PLT) clumping, is often found in clinical studies [1]. However, pseudothrombocytosis resulting from the fragmentation of red blood cells (RBCs) is a very rare phenomenon. EDTA-K2 anticoagulation was used on a sample of venous blood extracted from the patient. A Symex XN9000 automatic blood analyzer was used to conduct CBC + DIFF mode and CBC + DIFF + RET mode tests, stained smear microscopy. The Symex XN9000 automatic blood analyzer was used to conduct CBC + DIFF mode test; PLTs were measured at 570 x 109/L. Stained smear microscopy revealed the number of PLTs did not conform to the instrument measured 570 x 109/L. "RET" alarm instrument, switch to CBC + DIFF + RET mode for testing. The second test result showed PLTs at 128 x 109/L, which accords with artificial microscopy. This was a case of a very rare phenomenon: the fragmentation of RBCs caused pseudothrombocytosis.

  11. Evaluation of the testicular toxicity of prenatal exposure to bisphenol A based on microarray analysis combined with MeSH annotation.

    PubMed

    Tainaka, Hitoshi; Takahashi, Hikari; Umezawa, Masakazu; Tanaka, Hiromitsu; Nishimune, Yoshitake; Oshio, Shigeru; Takeda, Ken

    2012-01-01

    Bisphenol A (BPA) is known to be an endocrine disruptor that affects the development of reproductive system. The aim of the present study was to investigate a group of testicular genes dysregulated by prenatal exposure to BPA. Pregnant ICR mice were treated with BPA by subcutaneous administration on days 7 and 14 of pregnancy. Tissue and blood samples were collected from 6-week-old male offspring. Testes were subjected to gene expression analysis using a testis-specific microarray (Testis2), consisting of 2,482 mouse cDNA clones annotated with Medical Subject Headings (MeSH) terms indicative of testicular components and functions. To interpret the microarray data, we used the MeSH terms significantly associated with the altered genes. As a result, MeSH terms related to androgens and Sertoli cells were extracted in BPA-treated groups. Among the genes related to Sertoli cells, downregulation of Msi1h, Ncoa1, Nid1, Hspb2, and Gata6 were detected in the testis of mice treated with BPA (twice administered 50 mg/kg). The MeSH terms associated with this group of genes may provide useful means to interpret the testicular toxicity of BPA. This article concludes that prenatal BPA exposure downregulates expression of genes associated with Sertoli cell function and affects the reproductive function of male offspring. Additionally, a method using MeSH to extract a group of genes was useful for predicting the testicular and reproductive toxicity of prenatal BPA exposure.

  12. Ultrasound biomicroscopy (UBM) and scanning acoustic microscopy (SAM) for the assessment of hernia mesh integration: a comparison to standard histology in an experimental model.

    PubMed

    Petter-Puchner, A; Gruber-Blum, S; Walder, N; Fortelny, R H; Redl, H; Raum, K

    2014-08-01

    Mesh integration is a key parameter for reliable and safe hernia repair. So far, its assessment is based on histology obtained from rare second-look operations or experimental research. Therefore, non-invasive high-resolution imaging techniques would be of great value. Ultrasound biomicroscopy (UBM) and scanning acoustic microscopy (SAM) have shown potential in the imaging of hard and soft tissues. This experimental study compared the detection of mesh integration, foreign body reaction and scar formation in UBM/SAM with standard histology. Ten titanized polypropylene meshes were implanted in rats in a model of onlay repair. 17 days postoperative animals were killed and samples were paraffin embedded for histology (H&E, Cresyl violet) or processed for postmortem UBM/SAM. The observation period was uneventful and meshes appeared well integrated. Relocation of neighboring cross-sectional levels could easily be achieved with the 40-MHz UBM and granulation tissue could be distinguished from adjacent muscle tissue layers. The spatial resolution of approximately 8 μm of the 200-MHz UBM system images was comparable to standard histology (2.5-5× magnification) and allowed a clear identification of mesh fibers and different tissue types, e.g., scar, fat, granulation, and muscle tissues, as well as vessels, abscedations, and foreign body giant cell clusters. This pilot study demonstrates the potential of high-frequency ultrasound to assess hernia mesh integration non-invasively. Although the methods lack cell-specific information, tissue integration could reliably be assessed. The possibility of conducting UBM in vivo advocates this method as a guidance tool for the indication of second-look operations and subsequent elaborate histological analyses.

  13. Preclinical evaluation of the effect of the combined use of the Ethicon Securestrap® Open Absorbable Strap Fixation Device and Ethicon Physiomesh™ Open Flexible Composite Mesh Device on surgeon stress during ventral hernia repair

    PubMed Central

    Sutton, Nadia; MacDonald, Melinda H; Lombard, John; Ilie, Bodgan; Hinoul, Piet; Granger, Douglas A

    2018-01-01

    Aim To evaluate whether performing ventral hernia repairs using the Ethicon Physiomesh™ Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap® Open Absorbable Strap Fixation Device reduces surgical time and surgeon stress levels, compared with traditional surgical repair methods. Methods To repair a simulated ventral incisional hernia, two surgeries were performed by eight experienced surgeons using a live porcine model. One procedure involved traditional suture methods and a flat mesh, and the other procedure involved a mechanical fixation device and a skirted flexible composite mesh. A Surgery Task Load Index questionnaire was administered before and after the procedure to establish the surgeons’ perceived stress levels, and saliva samples were collected before, during, and after the surgical procedures to assess the biologically expressed stress (cortisol and salivary alpha amylase) levels. Results For mechanical fixation using the Ethicon Physiomesh Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap Open Absorbable Strap Fixation Device, surgeons reported a 46.2% reduction in perceived workload stress. There was also a lower physiological reactivity to the intraoperative experience and the total surgical procedure time was reduced by 60.3%. Conclusions This study provides preliminary findings suggesting that the combined use of a mechanical fixation device and a skirted flexible composite mesh in an open intraperitoneal onlay mesh repair has the potential to reduce surgeon stress. Additional studies are needed to determine whether a reduction in stress is observed in a clinical setting and, if so, confirm that this results in improved clinical outcomes. PMID:29296101

  14. Influence of cell shape on mechanical properties of Ti-6Al-4V meshes fabricated by electron beam melting method.

    PubMed

    Li, S J; Xu, Q S; Wang, Z; Hou, W T; Hao, Y L; Yang, R; Murr, L E

    2014-10-01

    Ti-6Al-4V reticulated meshes with different elements (cubic, G7 and rhombic dodecahedron) in Materialise software were fabricated by additive manufacturing using the electron beam melting (EBM) method, and the effects of cell shape on the mechanical properties of these samples were studied. The results showed that these cellular structures with porosities of 88-58% had compressive strength and elastic modulus in the range 10-300MPa and 0.5-15GPa, respectively. The compressive strength and deformation behavior of these meshes were determined by the coupling of the buckling and bending deformation of struts. Meshes that were dominated by buckling deformation showed relatively high collapse strength and were prone to exhibit brittle characteristics in their stress-strain curves. For meshes dominated by bending deformation, the elastic deformation corresponded well to the Gibson-Ashby model. By enhancing the effect of bending deformation, the stress-strain curve characteristics can change from brittle to ductile (the smooth plateau area). Therefore, Ti-6Al-4V cellular solids with high strength, low modulus and desirable deformation behavior could be fabricated through the cell shape design using the EBM technique. Copyright © 2014 Acta Materialia Inc. All rights reserved.

  15. The ESA/MBB unfurlable mesh antenna development for mobile services

    NASA Astrophysics Data System (ADS)

    Kellermeier, H.; Vorbrugg, H.; Pontoppidan, K.; Eaton, D. C. G.

    Mobile services via satellite in the 800-900 MHz frequency range have recently been studied by SPAR Aerospace Ltd in the M-SAT phase B using various unfurlable offset reflector concepts between 9 and 5 m aperture diameters for 6-, 4- and 2-beam coverage. For a 2-beam coverage of Canada and U.S.A. two offset antennas each of 5 m aperture diameter are required. The MBB offset unfurlable mesh antenna (UMA) developed since 1983 under an ESA contract is one of the attractive candidates: The design concept chosen uses foldable radial ribs of carbon fibre which deploy a gold plated molybdenum mesh on adjustable stand-offs. This concept is applicable for offset aperture diameters up to 12 m since the carbon fibre ribs are double folded and provide for a high package density when stowed at the spacecraft during launch. The electrical analysis performed by TICRA/Copenhagen was assisted by electrical measurements on mesh samples, verifying that main charactertics as ohmic resistance, transmission loss and passive intermodulation products (PIMP) lie within the required tolerances if the mesh is pretensioned to a certain configuration. For on-orbit testing and retrieval by the Shuttle the reflector shows a unique design feature of retractability by the reversable deployment sequence.

  16. Pyrolysis-catalysis of waste plastic using a nickel-stainless-steel mesh catalyst for high-value carbon products.

    PubMed

    Zhang, Yeshui; Nahil, Mohamad A; Wu, Chunfei; Williams, Paul T

    2017-11-01

    A stainless-steel mesh loaded with nickel catalyst was produced and used for the pyrolysis-catalysis of waste high-density polyethylene with the aim of producing high-value carbon products, including carbon nanotubes (CNTs). The catalysis temperature and plastic-to-catalyst ratio were investigated to determine the influence on the formation of different types of carbon deposited on the nickel-stainless-steel mesh catalyst. Increasing temperature from 700 to 900°C resulted in an increase in the carbon deposited on the nickel-loaded stainless-steel mesh catalyst from 32.5 to 38.0 wt%. The increase in sample-to-catalyst ratio reduced the amount of carbon deposited on the mesh catalyst in terms of g carbon g -1 plastic. The carbons were found to be largely composed of filamentous carbons, with negligible disordered (amorphous) carbons. Transmission electron microscopy analysis of the filamentous carbons revealed them to be composed of a large proportion (estimated at ∼40%) multi-walled carbon nanotubes (MWCNTs). The optimum process conditions for CNT production, in terms of yield and graphitic nature, determined by Raman spectroscopy, was catalysis temperature of 800°C and plastic-to-catalyst ratio of 1:2, where a mass of 334 mg of filamentous/MWCNTs g -1 plastic was produced.

  17. Comparison of two preparatory techniques for urine cytology.

    PubMed Central

    Dhundee, J; Rigby, H S

    1990-01-01

    Two methods of preparation of urine for cytology were compared retrospectively. In method 1 cells in the urine were fixed after the preparation of the smear; in method 2 the cells were fixed before smear preparation. Urine cytology reports were correlated with subsequent histological analysis. The specificities of urine cytology using both methods were high (99%). The sensitivity using method 1 was 87%; using method 2 it was 65%. This difference was significant. The cell preparation technique therefore significantly changes the sensitivity of urine cytology. Cellular fixation after smear preparation is preferable to smear preparation after fixation. PMID:2266176

  18. Historical data decrease complete blood count reflex blood smear review rates without missing patients with acute leukaemia.

    PubMed

    Rabizadeh, Esther; Pickholtz, Itay; Barak, Mira; Froom, Paul

    2013-08-01

    The availability of historical data decreases the rate of blood smear review rates in outpatients, but we are unaware of studies done at referral centres. In the following study, we determined the effect of historical data on the rates of peripheral blood smears over a 3-month period and then the detection rate of patients with acute leukaemia. All results of complete blood counts (CBCs) tested on three ADVIA 120 analyzers at the regional Rabin Medical Centre, Beilinson Campus over a 3-month period were accessed on a computerised laboratory information system. Over a 3-month period, we determined the proportion of total CBC and patients with criteria for a manual differential count and the actual number of peripheral blood smears done. Finally, we determined the proportion of 100 consecutive patients with acute leukaemia detected using our criteria that included limiting reflex testing according to historical data. Over the 3-month period, there were 34,827 tests done in 12,785 patients. Without historical data, our smear rate would have been 24.5%, but with the availability of historical data, the blood smear review rate was 5.6%. The detection rate for cases of acute leukaemia was 100%. We conclude that the availability of previous test results significantly reduces the need for blood smear review without missing any patients with acute leukaemia.

  19. The occurrence of hepatozoon in the gray squirrel (Sciurus carolinensis)

    USGS Publications Warehouse

    Herman, C.M.; Price, D.L.

    1955-01-01

    Hepatozoon sciuri (Coles, 1914) is reported from gray squirrels (Sciurus carolinensis) in Washington, D.C. and Maryland. Blood smears stained with Giemsa's stain revealed a parasitemia in 16 to 71% of the squirrels examined. A technique for laking the red cells and concentrating the white cells in blood samples demonstrated this protozoon to be present in every squirrel so tested.

  20. White-Light Optical Information Processing and Holography.

    DTIC Science & Technology

    1984-06-22

    Processing, Image Deblurring , Source Encoding, Signal Sampling, Coherence Measurement, Noise Performance, / Pseudocolor Encoding. , ’ ’ * .~ 10.ASS!RACT...o 2.1 Broad Spectral Band Color Image Deblurring .. . 4 2.2 Noise Performance ...... ...... .. . 4 2.3 Pseudocolor Encoding with Three Primary...spectra. This technique is particularly suitable for linear smeared color image deblurring . 2.2 Noise Performance In this period, we have also

  1. Effect of repeated arthrocentesis on cytologic analysis of synovial fluid in dogs.

    PubMed

    Berg, R I M; Sykes, J E; Kass, P H; Vernau, W

    2009-01-01

    Serial arthrocentesis and synovial fluid examination can be used to monitor treatment efficacy in immune-mediated polyarthritis (IMPA), but whether this procedure induces inflammation that interferes with test result interpretation is unknown. The aim of this study was to determine the effect of repeated arthrocentesis on synovial fluid cytology in healthy dogs. Nine healthy client-owned dogs. Prospective study. Arthrocentesis was performed under sedation on 4 joints (both carpi, 1 tarsus, 1 stifle) on each dog every 3 weeks, a total of 4 times. Automated cell counts were done on stifle fluid, smears were made, and differential cell counts done on smears from all joints. Slides were evaluated microscopically for erythrocyte numbers, total nucleated cell count, differential cell count, and cell morphology. Data were analyzed by 2-way analysis of variance. A total of 144 synovial fluid samples were examined. Repeated arthrocentesis was not associated with increases in synovial fluid neutrophil numbers. Mild mononuclear inflammation was detected in 13 samples from 6 dogs. Serial arthrocentesis at 3-week intervals can rarely be associated with mild mononuclear joint inflammation, but does not appear to induce neutrophilic inflammation, at least in healthy dogs, and can be useful to monitor treatment response in canine IMPA.

  2. Optoelectronic hit/miss transform for screening cervical smear slides

    NASA Astrophysics Data System (ADS)

    Narayanswamy, R.; Turner, R. M.; McKnight, D. J.; Johnson, K. M.; Sharpe, J. P.

    1995-06-01

    An optoelectronic morphological processor for detecting regions of interest (abnormal cells) on a cervical smear slide using the hit/miss transform is presented. Computer simulation of the algorithm tested on 184 Pap-smear images provided 95% detection and 5% false alarm. An optoelectronic implementation of the hit/miss transform is presented, along with preliminary experimental results.

  3. Evaluation and optimization of the extended information process unit (E-IPU) validation module integrating the sysmex flag systems and the recommendations of the French-speaking cellular hematology group (GFHC).

    PubMed

    Cornet, Edouard; Mullier, François; Despas, Noemie; Jacqmin, Hugues; Geara, Carole; Boubaya, Marouane; Chatelain, Bernard; Troussard, Xavier

    2016-10-01

    The French-Speaking Cellular Haematology Group (GFHC) recently published criteria for microscopic analysis of a blood smears when a hemogram is requested. In order to evaluate and improve these recommendations using an XN (Sysmex) analyzer, we assessed 31,836 samples categorized into two sub-groups of patients either receiving or not receiving care in the clinical hematology/oncology departments of two university hospitals. By combining the manufacturer's recommendations and the GFHC recommendations, 21.3% of samples had a positive review flag in phase 1 of our study (17,991 samples). In phase 2 (13,845 samples), increasing the immature granulocytes (IG) percentage from 5-10% as a review trigger threshold, and ignoring slides with isolated flags 'PLT HIGH' (thrombocytosis) or 'MCV LOW' (microcytosis) or 'Blast/Abn Lymph and Atypical Lymph' (blast cells/abnormal lymphocytes and atypical lymphocytes) (in the absence of abnormal cells on a previous blood smear within 72 h), enabled us to significantly reduce the number of slides reviewed from 21.3-15.0% (p < 0.0001), without loss of clinical value. This decrease occurred in both sub-groups (hematology 48.7-38.0%, non-hematology 18.3-11.7%, p < 0.0001). In conclusion, the application of the GFHC criteria adapted to XN analyzers has enabled us to optimize the hematology laboratory processes, and thus reduce the production costs and the turnaround time of hemogram results.

  4. Prevalence and molecular characterization of Theileria equi and Babesia caballi in jereed horses in Erzurum, Turkey.

    PubMed

    Guven, Esin; Avcioglu, Hamza; Deniz, Ahmet; Balkaya, İbrahim; Abay, Ugur; Yavuz, Şevki; Akyüz, Muzaffer

    2017-03-01

    Equine piroplasmosis (EP) is a hemoprotozoan tick-borne disease with worldwide distribution that is caused by Theileria equi and Babesia caballi. There are studies reporting the presence of equine piroplasmosis in Turkey but the situation in Erzurum is unknown. The aim of the current study was to determine the situation of equine piroplasmosis in jeered horses in Erzurum. Between April and August 2015, a total of 125 Arabian horse were examined and blood samples were collected. At the time of sampling, animals were also examined for tick infestations and clinical signs. Besides microscopic examination of Giemsastained blood smears, multiplex PCR performed with species specific primers partially amplifying the 18S rRNA gene of B. caballi and T. equi. During the microscopic examination of blood smears, T. equi piroplasms were found in 6 (4.8%) samples. In total, 11 (8.8%) T. equi DNA were detected with multiplex PCR. B. caballi piroplasms or DNA were not obtained. BLAST analysis of the sequenced T. equi samples (GenBank: KU921661-KU921667) indicated 98.8-100% identity to each other, and 100% similarity to T. equi isolates in South Africa, Iran, China, Sudan, India, Mongolia, Trinidad, Kenya, Spain, Serbia, Bosnia and Herzegovina and Turkey (Bursa). The results of our study indicate that T. equi occurs more frequently than B. caballi in the study area. To the authors' knowledge, this is the first report of the molecular detection of equine piroplasmosis in jeered horses in Erzurum, Turkey.

  5. A reappraisal of the role of mosquitoes in the transmission of myxomatosis in Britain.

    PubMed

    Service, M W

    1971-03-01

    Field experiments were made in southern England to re-examine the possibility that mosquitoes in Britain might feed on wild rabbits and hence be vectors of myxomatosis. Mosquitoes of several species were attracted to rabbits enclosed in cylindrical traps and in a trap in which the animal was placed in a wire mesh cage. Substantial numbers of mosquitoes were also caught biting, or attempting to bite, tethered rabbits which were not in cages or traps. Evidence that mosquitoes fed on wild rabbits under natural conditions was obtained from results of precipitin tests made on blood-smears collected from mosquitoes caught resting amongst vegetation. On a few evenings mosquitoes were seen to be attracted to healthy wild rabbits and apparently attempting to feed on them. Batches of two mosquito species collected from the field were infected with myxoma virus.It was concluded that contrary to previous beliefs mosquitoes in Britain feed to a certain extent on wild rabbits, and therefore are potential vectors of myxomatosis. No attempts were made to assess their relative importance in the transmission of the disease, which in Britain is transmitted mainly by the rabbit flea.

  6. A reappraisal of the role of mosquitoes in the transmission of myxomatosis in Britain

    PubMed Central

    Service, M. W.

    1971-01-01

    Field experiments were made in southern England to re-examine the possibility that mosquitoes in Britain might feed on wild rabbits and hence be vectors of myxomatosis. Mosquitoes of several species were attracted to rabbits enclosed in cylindrical traps and in a trap in which the animal was placed in a wire mesh cage. Substantial numbers of mosquitoes were also caught biting, or attempting to bite, tethered rabbits which were not in cages or traps. Evidence that mosquitoes fed on wild rabbits under natural conditions was obtained from results of precipitin tests made on blood-smears collected from mosquitoes caught resting amongst vegetation. On a few evenings mosquitoes were seen to be attracted to healthy wild rabbits and apparently attempting to feed on them. Batches of two mosquito species collected from the field were infected with myxoma virus. It was concluded that contrary to previous beliefs mosquitoes in Britain feed to a certain extent on wild rabbits, and therefore are potential vectors of myxomatosis. No attempts were made to assess their relative importance in the transmission of the disease, which in Britain is transmitted mainly by the rabbit flea. ImagesPlate 1 PMID:4401995

  7. Simulation of Complex Cracking in Plain Weave C/SiC Composite under Biaxial Loading

    NASA Technical Reports Server (NTRS)

    Cheng, Ron-Bin; Hsu, Su-Yuen

    2012-01-01

    Finite element analysis is performed on a mesh, based on computed geometry of a plain weave C/SiC composite with assumed internal stacking, to reveal the pattern of internal damage due to biaxial normal cyclic loading. The simulation encompasses intertow matrix cracking, matrix cracking inside the tows, and separation at the tow-intertow matrix and tow-tow interfaces. All these dissipative behaviors are represented by traction-separation cohesive laws. Not aimed at quantitatively predicting the overall stress-strain relation, the simulation, however, does not take the actual process of fiber debonding into account. The fiber tows are represented by a simple rule-of-mixture model where the reinforcing phase is a hypothetical one-dimensional material. Numerical results indicate that for the plain weave C/SiC composite, 1) matrix-crack initiation sites are primarily determined by large intertow matrix voids and interlayer tow-tow contacts, 2) the pattern of internal damage strongly depends on the loading path and initial stress, 3) compressive loading inflicts virtually no damage evolution. KEY WORDS: ceramic matrix composite, plain weave, cohesive model, brittle failure, smeared crack model, progressive damage, meso-mechanical analysis, finite element.

  8. DIFFERENCES IN CULTURAL YIELD OF MYCOBACTERIUM TUBERCULOSIS ON MEDIA PREPARED USING COMMERCIAL AND HOUSEHOLD EGGS.

    PubMed

    Noori, Muhammad Yahya; AJi, Zaheer; Khan, Ghazala; Sharafat, Shaheen; Masroor, Muhammad

    2015-01-01

    Mycobacterial culture is considered as the gold standard for TB diagnosis. It is performed on egg-based media using commercially available eggs to grow Mycobacteria from clinical samples. These eggs are known to contain high concentration of antibiotics, including fluoroquinolones, given to chicken to prevent early mortality. This study was performed to compare Mycobacterial growth on media prepared from commercial and antibiotic free household eggs. Sputum samples from negative (No bacilli in 100 oil immersion field), scanty (1-9 AFB in 100 fields), 1+ (10-99 bacilli per field), 2+ (1-10 bacilli per field) and 3+ (>10 bacilli per field) were inoculated dually on Ogawa medium prepared from commercial and household eggs. Tubes were inspected every fourth day for the appearance of colonies till 60 days. Data tabulations and statistical analysis (F test for variation and unpaired Student's t test) were performed on Microsoft Excel. One microscopically negative sample showed growth on media prepared from household eggs, while all were negative on that prepared from commercial eggs. There were significant differences in time to culture positivity for samples graded 1+ (p = 0.02), 2+ (p = 0.002) and 3+ (p = 0.0003). Commercial eggs containing antibiotics can be a source of false negativity in cultures especially in microscopically negative samples. This can be of special concern in HIV patients who have high smear negativity. It is therefore important to either develop provision of antibiotic free eggs for media preparation or to develop and validate other laboratory investigations for smear negative TB patients.

  9. Performance of the Xpert MTB/RIF assay for the diagnosis of pulmonary tuberculosis and rifampin resistance in a low-incidence, high-resource setting.

    PubMed

    Rice, Jason P; Seifert, Marva; Moser, Kathleen S; Rodwell, Timothy C

    2017-01-01

    Performance of the Xpert MTB/RIF assay, designed to simultaneously detect Mycobacterium tuberculosis complex (MTBC) and rifampin (RIF) resistance, has been well documented in low-resource settings with high TB-incidence. However, few studies have assessed its accuracy in low TB incidence settings. We evaluated the performance of Xpert MTB/RIF using clinical sputum specimens routinely collected from suspect pulmonary TB patients over a 4-year time period in San Diego County, California. Xpert MTB/RIF results were compared to acid-fast bacilli (AFB) smear microscopy, mycobacterial culture, and phenotypic drug susceptibility testing (DST). Of 751 sputum specimens, 134 (17.8%) were MTBC culture-positive and 2 (1.5%) were multidrug-resistant (MDR). For the detection of MTBC, Xpert MTB/RIF sensitivity was 89.6% (97.7% and 74.5% in smear-positive and -negative sputa, respectively) and specificity was 97.2%; while AFB smear sensitivity and specificity were 64.9% and 77.8%, respectively. Xpert MTB/RIF detected 35 of 47 smear-negative culture-positive specimens, and excluded 124 of 137 smear-positive culture-negative specimens. Xpert MTB/RIF also correctly excluded 99.2% (121/122) of nontuberculous mycobacteria (NTM) specimens, including all 33 NTM false-positives by smear microscopy. For the detection of RIF resistance, Xpert MTB/RIF sensitivity and specificity were 100% and 98.3%, respectively. Our findings demonstrate that Xpert MTB/RIF is able to accurately detect MTBC and RIF resistance in routinely collected respiratory specimens in a low TB-incidence setting, with comparable performance to that achieved in high-incidence settings; and suggest that under these conditions the assay has particular utility in detecting smear-negative TB cases, excluding smear-positive patients without MTBC disease, and differentiating MTBC from NTM.

  10. Performance of the Xpert MTB/RIF assay for the diagnosis of pulmonary tuberculosis and rifampin resistance in a low-incidence, high-resource setting

    PubMed Central

    Rice, Jason P.; Moser, Kathleen S.; Rodwell, Timothy C.

    2017-01-01

    Performance of the Xpert MTB/RIF assay, designed to simultaneously detect Mycobacterium tuberculosis complex (MTBC) and rifampin (RIF) resistance, has been well documented in low-resource settings with high TB-incidence. However, few studies have assessed its accuracy in low TB incidence settings. We evaluated the performance of Xpert MTB/RIF using clinical sputum specimens routinely collected from suspect pulmonary TB patients over a 4-year time period in San Diego County, California. Xpert MTB/RIF results were compared to acid-fast bacilli (AFB) smear microscopy, mycobacterial culture, and phenotypic drug susceptibility testing (DST). Of 751 sputum specimens, 134 (17.8%) were MTBC culture-positive and 2 (1.5%) were multidrug-resistant (MDR). For the detection of MTBC, Xpert MTB/RIF sensitivity was 89.6% (97.7% and 74.5% in smear-positive and -negative sputa, respectively) and specificity was 97.2%; while AFB smear sensitivity and specificity were 64.9% and 77.8%, respectively. Xpert MTB/RIF detected 35 of 47 smear-negative culture-positive specimens, and excluded 124 of 137 smear-positive culture-negative specimens. Xpert MTB/RIF also correctly excluded 99.2% (121/122) of nontuberculous mycobacteria (NTM) specimens, including all 33 NTM false-positives by smear microscopy. For the detection of RIF resistance, Xpert MTB/RIF sensitivity and specificity were 100% and 98.3%, respectively. Our findings demonstrate that Xpert MTB/RIF is able to accurately detect MTBC and RIF resistance in routinely collected respiratory specimens in a low TB-incidence setting, with comparable performance to that achieved in high-incidence settings; and suggest that under these conditions the assay has particular utility in detecting smear-negative TB cases, excluding smear-positive patients without MTBC disease, and differentiating MTBC from NTM. PMID:29016684

  11. Cost analysis of different diagnostic algorithms for pulmonary tuberculosis varying in placement of Xpert MTB/RIF.

    PubMed

    Chadha, V K; Sebastian, George; Kumar, P

    2016-01-01

    We undertook cost analysis for diagnosis of pulmonary tuberculosis (PTB) using present algorithm under Revised National Tuberculosis Control programme and using Xpert MTB/RIF (Xpert) as frontline test or in conjunction with smear microscopy and/or chest radiography. Costs were estimated for different strategies: (A) present algorithm involving sputum smear examination followed by antibiotic trial in smear negative patients, repeat smear examination (RE) if symptoms continue and chest radiography if RE negative; (B) direct Xpert; (C) smear microscopy followed by Xpert in smear negative patients; (D) radiography followed by Xpert in those having abnormal pulmonary shadows; and (E) smear examination followed by radiography among smear negative patients and Xpert in presence of abnormal pulmonary shadow. Cost to program was estimated lowest with Strategy A and highest with Strategy B. Compared to the latter, program cost reduces by 7%, 4.5%, and 17.4% by strategies C, D, and E, respectively. Cost to the group of individuals with presumptive PTB and their attendants is significantly higher for Strategy A compared to other four strategies. Among the latter, the patients' cost was minimum with Strategy B and maximum with Strategy C. Program cost per case diagnosed was lowest by Strategy A and highest by Strategy B. Patient cost per case diagnosed was highest by Strategy A and lowest by Strategy B. Using Xpert, Strategy E had the lowest program as well as overall cost per case diagnosed. Strategy E may be chosen for diagnosis of PTB. When resources would no longer be a constraint, direct Xpert would reduce costs incurred by the patients. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  12. Is the phone call the most effective method for recall in cervical cancer screening?--results from a randomised control trial.

    PubMed

    Abdul Rashid, Rima Marhayu; Mohamed, Majdah; Hamid, Zaleha Abdul; Dahlui, Maznah

    2013-01-01

    To compare the effectiveness of different methods of recall for repeat Pap smear among women who had normal smears in the previous screening. Prospective randomized controlled study. All community clinics in Klang under the Ministry of Health Malaysia. Women of Klang who attended cervical screening and had a normal Pap smear in the previous year, and were due for a repeat smear were recruited and randomly assigned to four different methods of recall for repeat smear. The recall methods given to the women to remind them for a repeat smear were either by postal letter, registered letter, short message by phone (SMS) or phone call. Number and percentage of women who responded to the recall within 8 weeks after they had received the recall, irrespective whether they had Pap test conducted. Also the numbers of women in each recall method that came for repeat Pap smear. The rates of recall messages reaching the women when using letter, registered letter, SMS and phone calls were 79%, 87%, 66% and 68%, respectively. However, the positive responses to recall by letter, registered letter, phone messages and telephone call were 23.9%, 23.0%, 32.9% and 50.9%, respectively (p<0.05). Furthermore, more women who received recall by phone call had been screened (p<0.05) compared to those who received recall by postal letter (OR=2.38, CI=1.56-3.62). Both the usual way of sending letters and registered letters had higher chances of reaching patients compared to using phone either for sending messages or calling. The response to the recall method and uptake of repeat smear, however, were highest via phone call, indicating the importance of direct communication.

  13. Evaluation of the smear layer removal and erosive capacity of EDTA, boric acid, citric acid and desy clean solutions: an in vitro study.

    PubMed

    Turk, Tugba; Kaval, Mehmet Emin; Şen, Bilge Hakan

    2015-09-03

    The purpose of this study was to investigate the smear layer removal and erosive capacity of various irrigation solutions with sequential use of NaOCl on instrumented root canal walls. The root canals of single-rooted teeth were instrumented with ProTaper rotary instrument. Then, the teeth were randomly divided into five experimental groups. The root canals were irrigated with one of the following solutions (5 mL/1 min): 5% EDTA, 5% boric acid (BA), a mixture of BA and CA, 2.5% citric acid (CA) and 5% Desy Clean. After irrigating with 2.5% NaOCl and distilled water, the roots were split into two halves and each half was prepared for SEM examination. Representative photographs were taken from each third at x500 and x1000 magnifications. Double blind scoring was performed by two calibrated observers for smear layer and erosion. The scores were statistically analyzed using Kruskal-Wallis, Dunn's post hoc and Spearman's correlation tests (p = 0.05). There were statistically significant differences among the solutions by means of smear layer and erosion (p < 0.05). While 2.5% CA solution was the most effective solution in removal of smear layer, it was also the most erosive solution (p < 0.05). 5% Desy Clean removed smear layer effectively and caused less erosion. There was a negative, but statistically significant correlation between presence of smear layer and erosion (r = -0.684; p < 0.0001). Desy Clean can be a promising agent as an irrigation solution with optimal smear layer removal capacity and less erosive effects.

  14. Hydrodynamic Drag Force Measurement Of A Functionalized Surface Exhibiting Superhydrophobic Properties

    DTIC Science & Technology

    2016-12-01

    22. Completed Test Stand. ...............................................................................24 Figure 23. Steel Spring and Mesh...topography that is superhydrophobic. Furthering this research, Zuhlke et al. [27] using FLSP, created stainless steel and titanium samples with...synthetic stomach acid. Each sample created attained initial wetting angles greater than 160 degrees while the stainless steel samples had a better

  15. Effect of Planned Follow-up on Married Women's Health Beliefs and Behaviors Concerning Breast and Cervical Cancer Screenings.

    PubMed

    Kolutek, Rahsan; Avci, Ilknur Aydin; Sevig, Umit

    2018-04-01

    The objective of this study was to identify the effect of planned follow-up visits on married women's health beliefs and behaviors concerning breast and cervical cancer screenings. The study was conducted using the single-group pre-test/post-test and quasi-experimental study designs. The sample of the study included 153 women. Data were collected using a Personal Information Form, the Health Belief Model (HBM) Scale for Breast Cancer Screening, the HBM Scale for Cervical Cancer Screening, and a Pap smear test. Data were collected using the aforementioned tools from September 2012 to March 2013. Four follow-up visits were conducted, nurses were educated, and telephone reminders were utilized. Friedman's test, McNemar's test, and descriptive statistics were used for data analyzing. The frequency of performing breast self-examination (BSE) at the last visit increased to 84.3 % compared to the pre-training. A statistically significant difference was observed between the pre- and post-training median values in four subscales except for the subscale of perceived seriousness of cervical cancer under "the Health Belief Model Scale for Cervical Cancer and the Pap Smear Test" (p < 0.001). The rate of performing BSE significantly increased after the training and follow-up visits. Also, the rate of having a Pap smear significantly increased after the follow-up visits.

  16. Comparative performance of PCR-based assay versus microscopy and culture for the direct detection of Mycobacterium tuberculosis in clinical respiratory specimens in Lebanon.

    PubMed

    Araj, G F; Talhouk, R S; Itani, L Y; Jaber, W; Jamaleddine, G W

    2000-09-01

    American University of Beirut Medical Center, Lebanon. To assess the performance of a polymerase chain reaction (PCR) using primers that flank 542 bp within IS6110 in Mycobacterium tuberculosis (TB) vs. microscopy and BACTEC culture, in the diagnosis of tuberculosis. A total of 82 clinical respiratory pulmonary specimens and 73 samples from BACTEC vials were tested by the three methods. Of 24 smear-positive culture-positive (SP-CP) and 11 smear-negative culture-positive (SN-CP) TB specimens, PCR detected 83% and 64%, respectively. Among 17 specimens yielding mycobacteria other than tuberculosis (MOTT), the PCR was positive in 33% SP-CP and 14% SN-CP specimens. Among the 73 BACTEC vials, PCR was positive in 36 of 38 (95%) yielding culture-positive TB, and in one of 20 (5%) yielding culture positive MOTT. None of the 30 smear-negative culture-negative (SN-CN) clinical specimens and 15 of the CN vials were positive by PCR. The overall sensitivity of PCR was 77% and 95% for TB detection in respiratory specimens and BACTEC vials, respectively, and the specificity was 94% in both. Because a substantial number of TB cases are missed, especially in SN-CP specimens, a PCR-based assay utilizing these primers cannot be used reliably, alone, in clinical laboratory diagnosis of mycobacterial respiratory infections.

  17. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology.

    PubMed

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, Br

    2012-01-01

    The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol-formalin as a fixative agent. Statistical analysis with the 'z test' was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ(2)test was used to identify the additional yield for malignancy by the CB method. Cellularity and additional yield for malignancy was 15% more by the CB method. The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method.

  18. Drug susceptibility of Mycobacterium tuberculosis in a rural area of Bangladesh and its relevance to the national treatment regimens.

    PubMed

    Van Deun, A; Aung, K J; Chowdhury, S; Saha, S; Pankaj, A; Ashraf, A; Rigouts, L; Fissette, K; Portaels, F

    1999-02-01

    Greater Mymensingh District, a rural area of Bangladesh, at the start of the National Tuberculosis Programme (NTP). To determine the prevalence of initial and acquired drug resistance of Mycobacterium tuberculosis, and to assess the appropriateness of the NTP's standard regimens. Sampling of pre-treatment sputum from all newly registered smear-positive cases in five centres covering the area. Culture and susceptibility testing in a supra-national reference laboratory. Initial resistance to isoniazid (H) was 5.4%, and to rifampicin (R) 0.5%. Acquired H and R resistance were 25.9% and 7.4%, respectively. Multidrug resistance (MDR) was observed in one new case only and in 5.6% of previously treated patients. Changing the present NTP indication for retreatment regimen to one month of previous H intake would increase coverage of H-resistant cases from 52% to 89%, adding 6% to drug costs. The prevalence of drug resistance is surprisingly low in Bangladesh, but could rise with improving economic conditions. The NTP regimens for smear-positive cases are appropriate, all the more so since the human immunodeficiency virus is virtually absent. Indications for the retreatment regimen should be extended to include all patients treated for at least one month with any drug. The NTP regimen for smear-negative cases runs the risk of leading to MDR under present field conditions.

  19. Significant decline in the tuberculosis burden in the Philippines ten years after initiating DOTS.

    PubMed

    Tupasi, T E; Radhakrishna, S; Chua, J A; Mangubat, N V; Guilatco, R; Galipot, M; Ramos, G; Quelapio, M I D; Beltran, G; Legaspi, J; Vianzon, R G; Lagahid, J

    2009-10-01

    The Philippines ranks ninth among the 22 high-burden countries for tuberculosis (TB). To measure the burden of pulmonary tuberculosis (PTB) in the Philippines and determine the impact of the DOTS strategy. The 2007 nationwide TB prevalence survey covered 50 clusters selected by multi-stage stratified random sampling from Metro Manila and other urban and rural areas. Subjects aged >or=10 years were screened radiographically for PTB to identify subjects for sputum examination and determine the prevalence of bacteriologically confirmed PTB, i.e., smear- and/or culture-positive PTB. In subjects aged >or=10 years, the 2007 prevalence of radiographic PTB was 6.3% (95%CI 5.5-7.1), bacteriologically confirmed PTB was 6.6 per 1000 (95%CI 5.1-8.1) and sputum smear-positive PTB was 2.6/1000 (95%CI 1.7-3.6). For the total population, the corresponding estimates were respectively 4.7%, 4.9/1000 and 2.0/1000. Between 1997 and 2007, there was a 31% reduction in bacteriologically confirmed PTB (P < 0.02) and a 27% reduction in smear-positive PTB (P = 0.18). This decline occurred despite the increasing poverty in the population. The survey demonstrated a significant decline in the TB burden 10 years after the implementation of DOTS, facilitated by a strategic public-private partnership.

  20. Burden of tuberculosis in intensive care units in Cape Town, South Africa, and assessment of the accuracy and effect on patient outcomes of the Xpert MTB/RIF test on tracheal aspirate samples for diagnosis of pulmonary tuberculosis: a prospective burden of disease study with a nested randomised controlled trial.

    PubMed

    Calligaro, Gregory L; Theron, Grant; Khalfey, Hoosain; Peter, Jonathan; Meldau, Richard; Matinyenya, Brian; Davids, Malika; Smith, Liezel; Pooran, Anil; Lesosky, Maia; Esmail, Aliasgar; Miller, Malcolm G; Piercy, Jenna; Michell, Lancelot; Dawson, Rodney; Raine, Richard I; Joubert, Ivan; Dheda, Keertan

    2015-08-01

    There are few prospective data about the incidence and mortality associated with pulmonary tuberculosis in intensive care units (ICUs), and none on the accuracy and clinical effect of the Xpert-MTB/RIF assay in this setting. We aimed to measure the frequency of culture-positive tuberculosis in ICUs in Cape Town, South Africa and to assess the performance and effect on patient outcomes of Xpert MTB/RIF versus smear microscopy for diagnosis of tuberculosis. We did a prospective burden of disease study with a randomised controlled substudy at the ICUs of four hospitals in Cape Town. Mechanically ventilated adults (≥18 years) with suspected pulmonary tuberculosis admitted between Aug 1, 2010, and July 31, 2013 (irrespective of the reason for admission), were prospectively investigated by culture, and by Xpert-MTB/RIF testing or smear microscopy, of tracheal aspirate samples. In the substudy, patients were randomly assigned (1:1), via a computer-generated allocation list, to smear microscopy or Xpert MTB/RIF. Participants, caregivers, and outcome assessors were not masked to group assignment. Only the laboratory staff were blinded to the clinical details of the participants. In November, 2012, Xpert MTB/RIF was adopted as the initial diagnostic test for respiratory samples in Western Cape province. Thereafter, patients received Xpert MTB/MIF and culture as standard of care. For the whole study cohort, the primary outcome was the frequency of bacteriologically confirmed tuberculosis. The primary endpoint of the randomised substudy was the proportion of culture-positive patients on treatment at 48 h after enrolment. The randomised substudy is registered with ClinicalTrials.gov, number NCT01530568. We investigated 341 patients for suspected pulmonary tuberculosis out of a total of 2309 ICU admissions. 46 (15%) of 317 patients included in the final analysis had a positive test for tuberculosis (Xpert MTB/RIF or culture). Culture-positive patients who failed to initiate treatment (adjusted HR 4·49, 95% CI 1·45-13·89) or who received inotropes (4·33, 1·49-12·60) were more likely to die. However, tuberculosis status was not associated with 28-day or 90-day mortality. In the substudy, we randomly assigned 115 patients to smear microscopy and 111 to Xpert MTB/RIF. Smear microscopy detected six (43%) of 14 culture-positive patients, and Xpert MTB/RIF detected 11 (100%) of 11 culture-positive patients (p=0·002). The proportion of culture-positive patients on treatment at 48 h was higher in the Xpert MTB/RIF group than in the smear microscopy group (11 [92%] of 12 vs nine [53%] of 17; p=0·043), although use of Xpert MTB/RIF had no effect on mortality or other patient outcomes. Tuberculosis is fairly common in ICUs in high-burden settings, and clinicians should screen and test patients for tuberculosis with Xpert MTB/RIF where available. This test improves diagnostic yield and rates of treatment initiation, and reduces unnecessary treatment, but might not increase the total number of patients on treatment when empirical treatment is widely used. A suspected diagnosis of pulmonary tuberculosis should not exclude patients from ICU care in resource-limited settings because mortality is unaffected by the presence of this disease. European and Developing Countries Clinical Trials Partnership, South African Medical Research Council, and the Discovery Foundation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study.

    PubMed

    Rabodoarivelo, Marie Sylvianne; Brandao, A; Cergole Novella, M C; C Bombonatte, A G; Imperiale, B; Rakotosamimanana, N; Morcillo, N; Rasolofo, V; Palomino, J C; Martin, A

    2018-01-01

    In low-income countries, rapid detection of tuberculosis (TB) drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF) and isoniazid (INH) resistance. This was a multicenter study. Molecular detection of RIF and INH resistance was performed directly from smear-positive TB sputa spotted on a slide, FTA card, GenoCard, and ethanol using the Genotype MTBDRplus assay. The performance of the DNA extraction method from each storage support to detect drug resistance was assessed by calculating their sensitivity and specificity compared to the phenotypic method. From all sites, the overall sensitivity and specificity for RIF-resistance detection was 88% and 85%, respectively, for slides, 86% and 92%, respectively, for GenoCard, 87% and 89%, respectively, for FTA card, and 88% and 92%, respectively, for ethanol. For INH-resistance detection, the overall sensitivity and specificity was 82% and 90%, respectively, for slides, 85% and 96%, respectively, for GenoCard, 86% and 92%, respectively, for FTA card, and 86% and 94%, respectively, for ethanol. Smear slides and filter cards showed to be very useful tools to facilitate DNA extraction from sputum samples with the potential to accelerate the detection of drug resistance in remote areas.

  2. Trypanosoma cruzi infection in captive Neotropical primates in the Brazilian Amazon.

    PubMed

    Bahia, Michele; de Nazaré Leite Barros, Flávia; Magalhães-Matos, Paulo Cesar; de Souza Gonçalves, Thamirys; Chiesorin Neto, Laerzio; Oliveira Faria, Diogo Cesar Lagroteria; Aparecida Romeiro, Sandra; Barros Monteiro, Frederico Ozanan; Góes-Cavalcante, Gustavo; Scofield, Alessandra

    2017-02-01

    The aim of this study was to detect the infection by Trypanosoma cruzi in captive Neotropical primates in the Brazilian Amazon. From February 2013 to July 2014, 112 blood samples were collected from Neotropical primates from the Amazonas, Amapá, and Pará States, north of Brazil. The subjects belonged to the families Cebidae (N = 59), Atelidae (N = 41), Callitrichidae (N = 5), Pitheciidae (N = 4), and Aotidae (N = 3). Blood smears also were examined for the presence of trypomastigotes by optical microscopy. For the detection of T. cruzi DNA, a Nested-PCR with primers TCZ1/TCZ2 and TCZ3/TCZ4 was performed. T. cruzi DNA was detected in 12.5% (14/112) of Neotropical primates examined. Positive samples were detected in 16%, 12.5%, and 11.11% of the different species of primates sampled from the Amapá, Pará, and Amazonas states, respectively. The analysis of the blood smears did not reveal trypomastigote forms of T. cruzi. In conclusion, Neotropical primates kept in captivity were infected by T. cruzi in the studied areas. We recommend that a health management protocol be put into place to prevent the transmission of infectious agents among captive populations, captive and wild populations, and between NHPs and the technicians who handle these animals. © 2016 Wiley Periodicals, Inc.

  3. The emergence of Leishmania major and Leishmania donovani in southern Turkey.

    PubMed

    Koltas, Ismail S; Eroglu, Fadime; Alabaz, Derya; Uzun, Soner

    2014-03-01

    In southern Turkey, Leishmania tropica and L. infantum are both the causative agents of cutaneous leishmaniasis (CL) and visceral leishmaniasis (VL), respectively. However, L. major and L. donovani were known to exist after the influx of Syrian refugees. Between the years of July 2003 and July 2013, a total of 167 smears and 113 bone marrow samples were taken from CL and VL-suspected cases, respectively. Samples were analysed through real-time PCR and ITS1 DNA sequencing. One hundred and seven 64% (107/167) smears and 56% (63/113) bone marrow samples were positive for leishmaniasis according to the real-time PCR. Three different Leishmania species were found in the 107 CL cases by real-time PCR: 42% (45/107) L. tropica, 36.5% (39/107) L. infantum and 21.5% (23/107) L. major. In addition, three different Leishmania species were identified in the 63 VL cases: 60.3% (38/63) L. infantum, 30.2% (19/63) L. donovani and 9.5% (6/63) L. tropica using real-time PCR. The results of real-time PCR were confirmed with Leishmania ITS1 DNA sequencing. This study revealed that in southern Turkey, L. major and L. donovani were the aetiological agents of CL and VL, respectively. It was assumed that emergence of L. major and L. donovani was due to influx of Syrian refugees, as well as the effects of global warming.

  4. The change is length and width of the Sertoli cell nuclei in cytologic smears of testes with depopulation of the seminiferous epithelium.

    PubMed

    Banek, L; Posinovec, J

    1980-09-15

    The appearance of the Sertoli cells in cytological smears of tests with depopulation of the seminiferous epithelium is described. The mean values of the lengths and widths of the Sertoli cell nuclei in smears differed significantly between the depopulation and the control group (p < 0.01).

  5. Papanicolaou Smear Screening of Women with Intellectual Disabilities: A Cross-Sectional Survey in Taiwan

    ERIC Educational Resources Information Center

    Lin, Lan-Ping; Lin, Jin-Ding; Sung, Chang-Lin; Liu, Ta-Wen; Liu, Yi-Lian; Chen, Li-Mei; Chu, Cordia M.

    2010-01-01

    Although little is known about the incidence of cervical cancer in women with intellectual disabilities (ID), Pap smear screening is an effective public health program to prevent cervical cancer to this group of people. The purposes of this study were to identify and evaluate the factors regarding the utilization of the Pap smears in women with ID…

  6. Natural History of Tuberculosis: Duration and Fatality of Untreated Pulmonary Tuberculosis in HIV Negative Patients: A Systematic Review

    PubMed Central

    Tiemersma, Edine W.; van der Werf, Marieke J.; Borgdorff, Martien W.; Williams, Brian G.; Nagelkerke, Nico J. D.

    2011-01-01

    Background The prognosis, specifically the case fatality and duration, of untreated tuberculosis is important as many patients are not correctly diagnosed and therefore receive inadequate or no treatment. Furthermore, duration and case fatality of tuberculosis are key parameters in interpreting epidemiological data. Methodology and Principal Findings To estimate the duration and case fatality of untreated pulmonary tuberculosis in HIV negative patients we reviewed studies from the pre-chemotherapy era. Untreated smear-positive tuberculosis among HIV negative individuals has a 10-year case fatality variously reported between 53% and 86%, with a weighted mean of 70%. Ten-year case fatality of culture-positive smear-negative tuberculosis was nowhere reported directly but can be indirectly estimated to be approximately 20%. The duration of tuberculosis from onset to cure or death is approximately 3 years and appears to be similar for smear-positive and smear-negative tuberculosis. Conclusions Current models of untreated tuberculosis that assume a total duration of 2 years until self-cure or death underestimate the duration of disease by about one year, but their case fatality estimates of 70% for smear-positive and 20% for culture-positive smear-negative tuberculosis appear to be satisfactory. PMID:21483732

  7. Effects of spectral smearing on performance of the spectral ripple and spectro-temporal ripple tests.

    PubMed

    Narne, Vijaya Kumar; Sharma, Mridula; Van Dun, Bram; Bansal, Shalini; Prabhu, Latika; Moore, Brian C J

    2016-12-01

    The main aim of this study was to use spectral smearing to evaluate the efficacy of a spectral ripple test (SRt) using stationary sounds and a recent variant with gliding ripples called the spectro-temporal ripple test (STRt) in measuring reduced spectral resolution. In experiment 1 the highest detectable ripple density was measured using four amounts of spectral smearing (unsmeared, mild, moderate, and severe). The thresholds worsened with increasing smearing and were similar for the SRt and the STRt across the three conditions with smearing. For unsmeared stimuli, thresholds were significantly higher (better) for the STRt than for the SRt. An amplitude fluctuation at the outputs of simulated (gammatone) auditory filters centered above 6400 Hz was identified as providing a potential detection cue for the STRt stimuli. Experiment 2 used notched noise with energy below and above the passband of the SRt and STRt stimuli to reduce confounding cues in the STRt. Thresholds were almost identical for the STRt and SRt for both unsmeared and smeared stimuli, indicating that the confounding cue for the STRt was eliminated by the notched noise. Thresholds obtained with notched noise present could be predicted reasonably accurately using an excitation-pattern model.

  8. Microscopic diagnosis of dysbacteriosis in stained vaginal smears in clinical practice.

    PubMed

    Verbruggen, Banut-Sabine M; Boon, Mathilde E; Melkerl, Peter; van Haaften, Maarten; Heintz, A Peter M

    2006-10-01

    Dysbacteriosis is a microscopical diagnosis. In women with dysbacteriosis, an overgrowth of coccoid bacteria and almost a complete absence of lactobacilli are observed in the (stained) vaginal smear. The aim of this study was to determine the accuracy of this microscopic diagnosis in clinical practice. The analysis concerned 342 consecutive cases in which the microscopy of the stained smears was performed by general practitioners trained in diagnosing dysbacteriosis. These smears were sent to the pathologist for confirmation of the microscopical diagnosis of the clinician. The cytological diagnoses of the pathologist, sometimes performed on restained slides when the quality of the staining was substandard, were considered as the "gold standard." In 92 of the 342 cases, dysbacteriosis was unequivocally established by the pathologist. Sensitivity and specificity of the microscopical diagnoses of the clinicians were 40% and 85%, respectively. There were 37 false-positive and 54 false-negative diagnoses of dysbacteriosis rendered by the clinicians. The most frequent reason for a false-negative diagnosis was an excess of lactobacilli in the smear. This study shows that even in stained smears it is difficult for clinicians to render a correct evaluation of the status of the vaginal flora.

  9. Radio-frequency heating to inactivate Salmonella Typhimurium and Escherichia coli O157:H7 on black and red pepper spice.

    PubMed

    Kim, Sung-Youn; Sagong, Hun-Gu; Choi, Sang Ho; Ryu, Sangryeol; Kang, Dong-Hyun

    2012-02-01

    The efficacy of radio-frequency (RF) heating to inactivate Salmonella Typhimurium and Escherichia coli O157:H7 on black and red pepper spice was investigated. A 27.12 MHz RF heating system consisted of two parallel-plate electrodes was used, with the sample being placed between them. Black peppers (whole and ground) and red peppers (+ 16 mesh, -16 + 25 mesh, and -25 mesh) inoculated with S. Typhimurium and E. coli O157:H7 were treated with RF energy during 50s for black peppers and 40s for red peppers, and color change of samples was evaluated after treatment. RF heating for 50s resulted in 2.80 to 4.29 log CFU/g reductions of S. Typhimurium and E. coli O157:H7 in black peppers and RF heating of red peppers for 40s reduced pathogens by 3.38 log CFU/g to more than 5 log CFU/g (below the detection limit) without affecting the color quality change. The results suggest that RF heating has the potential for novel thermal process to control foodborne pathogens in spice. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Association between Pap smear screening and job stress in Taiwanese nurses.

    PubMed

    Su, Shiang-Yuan; Chiou, Shu-Ti; Huang, Nicole; Huang, Chiu-Mieh; Chiang, Jen-Huai; Chien, Li-Yin

    2016-02-01

    Nursing is a professional job characterized by high stress. Stress could be associated with less practice of health promoting behaviors; however, no study has investigated the relationship between job stress and health screening behaviors among nurses. This study aimed to describe the rate of Pap smears in hospital nurses and examine the effects of job stress on receiving a Pap smear. This study was a cross-sectional survey. The study participants were 30,681 full-time female nurses who were at least 30 years of age working in 100 hospitals across Taiwan. The study participants filled out an anonymous structured questionnaire from May to July, 2011. The outcome variable was having a Pap test during the previous 3 years. The level of stress was measured by a 19-item scale, with higher scores indicating higher stress levels. About 62.4% of the nurses had a Pap smear during the previous three years. Each point increase in the stress score decreased the likelihood of Pap smears (OR = .997, 95% CI: .995-.999), after adjustment for participant characteristics, health status, health behaviors, and hospital characteristics. Despite more knowledge and higher accessibility, nurses were less likely to have Pap smear screening than the general population. A higher level of job stress was associated with a lower likelihood of having a Pap smear. Hospital administrators could help decrease work-related stress and improve stress adaption among nurses in order to improve their health screening behaviors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Stochastic, compartmental, and dynamic modeling of cross-contamination during mechanical smearing of cheeses.

    PubMed

    Aziza, Fanny; Mettler, Eric; Daudin, Jean-Jacques; Sanaa, Moez

    2006-06-01

    Cheese smearing is a complex process and the potential for cross-contamination with pathogenic or undesirable microorganisms is critical. During ripening, cheeses are salted and washed with brine to develop flavor and remove molds that could develop on the surfaces. Considering the potential for cross-contamination of this process in quantitative risk assessments could contribute to a better understanding of this phenomenon and, eventually, improve its control. The purpose of this article is to model the cross-contamination of smear-ripened cheeses due to the smearing operation under industrial conditions. A compartmental, dynamic, and stochastic model is proposed for mechanical brush smearing. This model has been developed to describe the exchange of microorganisms between compartments. Based on the analytical solution of the model equations and on experimental data collected with an industrial smearing machine, we assessed the values of the transfer parameters of the model. Monte Carlo simulations, using the distributions of transfer parameters, provide the final number of contaminated products in a batch and their final level of contamination for a given scenario taking into account the initial number of contaminated cheeses of the batch and their contaminant load. Based on analytical results, the model provides indicators for smearing efficiency and propensity of the process for cross-contamination. Unlike traditional approaches in mechanistic models, our approach captures the variability and uncertainty inherent in the process and the experimental data. More generally, this model could represent a generic base to use in modeling similar processes prone to cross-contamination.

  12. Dense mesh sampling for video-based facial animation

    NASA Astrophysics Data System (ADS)

    Peszor, Damian; Wojciechowska, Marzena

    2016-06-01

    The paper describes an approach for selection of feature points on three-dimensional, triangle mesh obtained using various techniques from several video footages. This approach has a dual purpose. First, it allows to minimize the data stored for the purpose of facial animation, so that instead of storing position of each vertex in each frame, one could store only a small subset of vertices for each frame and calculate positions of others based on the subset. Second purpose is to select feature points that could be used for anthropometry-based retargeting of recorded mimicry to another model, with sampling density beyond that which can be achieved using marker-based performance capture techniques. Developed approach was successfully tested on artificial models, models constructed using structured light scanner, and models constructed from video footages using stereophotogrammetry.

  13. A MORE COST-EFFECTIVE EMAP BENTHIC MACROFAUNAL SAMPLING PROTOCOL

    EPA Science Inventory

    Benthic macrofaunal sampling protocols in the U.S. Environmental Protection Agency's Environmental Monitoring and Assessment Program (EMAP) are to collect 30 to 50 random benthic macrofauna [defined as animals retained on a 0.5 mm (East and Gulf Coasts, USA) or a 1.0 mm mesh siev...

  14. Polymerase Chain Reaction in the Diagnosis of Visceral Leishmaniasis Recurrence in the Setting of Negative Splenic Smears

    PubMed Central

    Hasnain, Golam; Basher, Ariful; Nath, Proggananda; Ghosh, Prakash; Hossain, Faria; Hossain, Shakhawat; Mondal, Dinesh

    2016-01-01

    This report presents two cases of visceral leishmaniasis (VL) recurrence where the microscopy of the splenic smear failed in diagnosis. However, a strong clinical suspicion compelled further evaluation by polymerase chain reaction (PCR), which validated the etiology. This short report highlights the usefulness of PCR in diagnosing cases of suspected smear-negative VL recurrence. PMID:26556834

  15. Cost Analysis of a Nucleic Acid Amplification Test in the Diagnosis of Pulmonary Tuberculosis at an Urban Hospital with a High Prevalence of TB/HIV

    PubMed Central

    Wang, Yun F.; Leonard, Michael K.; White, Nancy; McFarland, Deborah A.; Blumberg, Henry M.

    2014-01-01

    Introduction The Centers for Disease Control and Prevention has recommended using a nucleic acid amplification test (NAAT) for diagnosing pulmonary tuberculosis (TB) but there is a lack of data on NAAT cost-effectiveness. Methods We conducted a prospective cohort study that included all patients with an AFB smear-positive respiratory specimen at Grady Memorial Hospital in Atlanta, GA, USA between January 2002 and June 2008. We determined the sensitivity, specificity, and positive and negative predictive value of a commercially available and FDA-approved NAAT (amplified MTD, Gen-Probe) compared to the gold standard of culture. A cost analysis was performed and included costs related to laboratory tests, hospital charges, anti-TB medications, and contact investigations. Average cost per patient was calculated under two conditions: (1) using a NAAT on all AFB smear-postive respiratory specimens and (2) not using a NAAT. One-way sensitivity analyses were conducted to determine sensitivity of cost difference to reasonable ranges of model inputs. Results During a 6 1/2 year study period, there were 1,009 patients with an AFB smear-positive respiratory specimen at our public urban hospital. We found the NAAT to be highly sensitive (99.6%) and specific (99.1%) on AFB smear-positive specimens compared to culture. Overall, the positive predictive value (PPV) of an AFB smear-positive respiratory specimen for culture-confirmed TB was 27%. The PPV of an AFB smear-positive respiratory specimen for culture-confirmed TB was significantly higher for HIV-uninfected persons compared to those who were HIV-seropositive (152/271 [56%] vs. 85/445 [19%]; RR = 2.94, 95% CI 2.36–3.65, p<0.001). The cost savings of using the NAAT was $2,003 per AFB smear-positive case. Conclusions Routine use of the NAAT on AFB smear-positive respiratory specimens was highly cost-saving in our setting at a U.S. urban public hospital with a high prevalence of TB and HIV because of the low PPV of an AFB smear for culture-confirmed TB. PMID:25014783

  16. Evaluation of the 2007 WHO Guideline to Improve the Diagnosis of Tuberculosis in Ambulatory HIV-Positive Adults

    PubMed Central

    Koole, Olivier; Thai, Sopheak; Khun, Kim Eam; Pe, Reaksmey; van Griensven, Johan; Apers, Ludwig; Van den Ende, Jef; Mao, Tan Eang; Lynen, Lutgarde

    2011-01-01

    Background In 2007 WHO issued a guideline to improve the diagnosis of smear-negative and extrapulmonary tuberculosis (EPTB) in HIV-positive patients. This guideline relies heavily on the acceptance of HIV-testing and availability of chest X-rays. Methods and Findings Cohort study of TB suspects in four tuberculosis (TB) clinics in Phnom Penh, Cambodia. We assessed the operational performance of the guideline, the incremental yield of investigations, and the diagnostic accuracy for smear-negative tuberculosis in HIV-positive patients using culture positivity as reference standard. 1,147 (68.9%) of 1,665 TB suspects presented with unknown HIV status, 1,124 (98.0%) agreed to be tested, 79 (7.0%) were HIV-positive. Compliance with the guideline for chest X-rays and sputum culture requests was 97.1% and 98.3% respectively. Only 35 of 79 HIV-positive patients (44.3%) with a chest X-ray suggestive of TB started TB treatment within 10 days. 105 of 442 HIV-positive TB suspects started TB treatment (56.2% smear-negative pulmonary TB (PTB), 28.6% smear-positive PTB, 15.2% EPTB). The median time to TB treatment initiation was 5 days (IQR: 2–13 days), ranging from 2 days (IQR: 1–11.5 days) for EPTB, over 2.5 days (IQR: 1–4 days) for smear-positive PTB to 9 days (IQR: 3–17 days) for smear-negative PTB. Among the 34 smear-negative TB patients with a confirmed diagnosis, the incremental yield of chest X-ray, clinical suspicion or abdominal ultrasound, and culture was 41.2%, 17.6% and 41.2% respectively. The sensitivity and specificity of the algorithm to diagnose smear-negative TB in HIV-positive TB suspects was 58.8% (95%CI: 42.2%–73.6%) and 79.4% (95%CI: 74.8%–82.4%) respectively. Conclusions Pending point-of-care rapid diagnostic tests for TB disease, diagnostic algorithms are needed. The diagnostic accuracy of the 2007 WHO guideline to diagnose smear-negative TB is acceptable. There is, however, reluctance to comply with the guideline in terms of immediate treatment initiation. PMID:21494694

  17. Evaluation of the 2007 WHO guideline to improve the diagnosis of tuberculosis in ambulatory HIV-positive adults.

    PubMed

    Koole, Olivier; Thai, Sopheak; Khun, Kim Eam; Pe, Reaksmey; van Griensven, Johan; Apers, Ludwig; Van den Ende, Jef; Mao, Tan Eang; Lynen, Lutgarde

    2011-04-06

    In 2007 WHO issued a guideline to improve the diagnosis of smear-negative and extrapulmonary tuberculosis (EPTB) in HIV-positive patients. This guideline relies heavily on the acceptance of HIV-testing and availability of chest X-rays. Cohort study of TB suspects in four tuberculosis (TB) clinics in Phnom Penh, Cambodia. We assessed the operational performance of the guideline, the incremental yield of investigations, and the diagnostic accuracy for smear-negative tuberculosis in HIV-positive patients using culture positivity as reference standard. 1,147 (68.9%) of 1,665 TB suspects presented with unknown HIV status, 1,124 (98.0%) agreed to be tested, 79 (7.0%) were HIV-positive. Compliance with the guideline for chest X-rays and sputum culture requests was 97.1% and 98.3% respectively. Only 35 of 79 HIV-positive patients (44.3%) with a chest X-ray suggestive of TB started TB treatment within 10 days. 105 of 442 HIV-positive TB suspects started TB treatment (56.2% smear-negative pulmonary TB (PTB), 28.6% smear-positive PTB, 15.2% EPTB). The median time to TB treatment initiation was 5 days (IQR: 2-13 days), ranging from 2 days (IQR: 1-11.5 days) for EPTB, over 2.5 days (IQR: 1-4 days) for smear-positive PTB to 9 days (IQR: 3-17 days) for smear-negative PTB. Among the 34 smear-negative TB patients with a confirmed diagnosis, the incremental yield of chest X-ray, clinical suspicion or abdominal ultrasound, and culture was 41.2%, 17.6% and 41.2% respectively. The sensitivity and specificity of the algorithm to diagnose smear-negative TB in HIV-positive TB suspects was 58.8% (95%CI: 42.2%-73.6%) and 79.4% (95%CI: 74.8%-82.4%) respectively. Pending point-of-care rapid diagnostic tests for TB disease, diagnostic algorithms are needed. The diagnostic accuracy of the 2007 WHO guideline to diagnose smear-negative TB is acceptable. There is, however, reluctance to comply with the guideline in terms of immediate treatment initiation.

  18. Diagnostic accuracy of same-day microscopy versus standard microscopy for pulmonary tuberculosis: a systematic review and meta-analysis.

    PubMed

    Davis, J Lucian; Cattamanchi, Adithya; Cuevas, Luis E; Hopewell, Philip C; Steingart, Karen R

    2013-02-01

    Sputum smear microscopy is the most widely available diagnostic test for pulmonary tuberculosis in countries with a high burden of the disease. Improving its accuracy is crucial to achievement of case-detection targets established by the Millennium Development Goals. Unfortunately, many patients are unable to submit all of the specimens needed for examination or to return for treatment because standard sputum collection and reporting requires several clinic visits. To inform policy recommendations by a WHO-convened Expert Group, we aimed to assess the accuracy of sputum smear examination with strategies for obtaining sputum on 1 day compared with strategies for obtaining sputum over 2 days. We did a systematic review and meta-analysis of research articles comparing the accuracy of front-loaded or same-day microscopy and standard sputum smear microscopy for diagnosis of culture-confirmed pulmonary tuberculosis. We searched Medline, Embase, Biosis, and Web of Science for articles published between Jan 1, 2005, and Feb 14, 2012. Two investigators identified eligible articles and extracted data for individual study sites. We generated pooled summary estimates (95% CIs) for sensitivity and specificity by use of random-effects meta-analysis when four or more studies were available. We identified eight relevant studies from five articles enrolling 7771 patients with suspected tuberculosis in low-income countries. Compared with the standard approach of examination of two smears with Ziehl-Neelsen light microscopy over 2 days, examination of two smears taken on the same day had much the same sensitivity (64% [95% CI 60 to 69] for standard microscopy vs 63% [58 to 68] for same-day microscopy) and specificity (98% [97 to 99] vs 98% [97 to 99]). We noted similar results for studies employing light-emitting diode fluorescence microscopy and for studies examining three smears, whether they were compared with two-smear strategies or with one another. Same-day sputum smear microscopy is as accurate as standard smear microscopy. Data from tuberculosis programmes are needed to document the changes required in the health system to successfully implement the strategy and understand its effects. WHO and US National Institutes of Health. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Identification of Primary Drug Resistance to Rifampin in Mycobacterium leprae Strains from Leprosy Patients in Amazonas State, Brazil

    PubMed Central

    Contreras Mejía, Matilde del Carmen; Porto Dos Santos, Maísa; Villarouco da Silva, George Allan; da Motta Passos, Isabella; Naveca, Felipe Gomes; Souza Cunha, Maria da Graça; Moraes, Milton Ozório

    2014-01-01

    The aim of this study was to identify polymorphisms in the folp1, gyrA, and rpoB genes in leprosy patients treated in Amazonas State, Brazil. Among 197 slit-skin smear samples from untreated or relapsed patients, we found three cases of primary resistance to rifampin and one confirmed case of multidrug resistance. PMID:25274993

  20. The use of a differential fluorescent staining method to detect bacteriuria.

    PubMed

    Ciancaglini, Ettore; Fazii, Paolo; Sforza, Giuseppe Riario

    2004-01-01

    This report describes a differential staining method which distinguishes gram-positive from gram-negative bacteria in fluorescence. Gram-positive bacteria appear yellow and gram-negative bacteria appear green. The method is based on two fluorochromes, one acting in the wavelength of red, i.e. the acridine orange, and another acting in the wavelength of green, i.e. the fluorescein, which together form a red/ green system. In this report we compared the accuracy of the differential fluorescent staining method and the Gram stain in screening for bacteriuria, as detected by conventional cultures. A total of 1487 urine samples were tested. 289 cultures were positive. 237 specimens grew a single organism at 10(5) and 10(4) CFU/ml. 224 smears were detected by the differential fluorescent staining method and 162 were detected by Gram stain. 1198 samples failed to grow organisms at 10(5) and 10(4) CFU/ml. 107 smears were falsely positive by the fluorescent staining procedure and 289 were falsely positive by the Gram stain. On the basis of the culture results, the sensitivity of the differential fluorescent staining method was 94.5% and that of the Gram stain 68.3%. The specificity of the fluorescent staining procedure was 91.6% and that of the Gram stain 75.8%. The positive predictive value and the negative predictive value of the fluorescent staining method were 67.6% and 98.8%, respectively. Those of the Gram stain were 35.9% and 92.3%, respectively. A wide range of microbiological and chemical techniques are available to identify bacteria in urine. This fluorescent staining method represents a simple, rapid, reliable method with low-running costs. The main advantage of this technique is that it enables the microbiologist to exclude the presence of bacteria in the urine within a short time after specimen receipt and to eliminate a large number of specimens for culture with significant cost saving. Another advantage of the method is that it allows to distinguish gram-positive from gram-negative bacteria in positive slides on the same day the sample is obtained. The stained smears were easily interpreted, even when the bacterial counts in the specimen were low.

Top