Comparison of current meters used for stream gaging
Fulford, Janice M.; Thibodeaux, Kirk G.; Kaehrle, William R.
1994-01-01
The U.S. Geological Survey (USGS) is field and laboratory testing the performance of several current meters used throughout the world for stream gaging. Meters tested include horizontal-axis current meters from Germany, the United Kingdom, and the People's Republic of China, and vertical-axis and electromagnetic current meters from the United States. Summarized are laboratory test results for meter repeatability, linearity, and response to oblique flow angles and preliminary field testing results. All current meters tested were found to under- and over-register velocities; errors usually increased as the velocity and angle of the flow increased. Repeatability and linearity of all meters tested were good. In the field tests, horizontal-axis meters, except for the two meters from the People's Republic of China, registered higher velocity than did the vertical-axis meters.
The effects of vertical motion on the performance of current meters
Thibodeaux, K.G.; Futrell, J. C.
1987-01-01
A series of tests to determine the correction coefficients for Price type AA and Price type OAA current meters, when subjected to vertical motion in a towing tank, have been conducted. During these tests, the meters were subjected to vertical travel that ranged from 1.0 to 4.0 ft and vertical rates of travel that ranged from 0.33 to 1.20 ft/sec while being towed through the water at speeds ranging from 0 to 8 ft/sec. The tests show that type AA and type OAA current meters are affected adversely by the rate of vertical motion and the distance of vertical travel. In addition, the tests indicate that when current meters are moved vertically, correction coefficients must be applied to the observed meter velocities to correct for the registration errors that are induced by the vertical motion. The type OAA current meter under-registers and the type AA current meter over-registers in observed meter velocity. These coefficients for the type OAA current meter range from 0.99 to 1.49 and for the type AA current meter range from 0.33 to 1.07. When making current meter measurements from a boat or a cableway, errors in observed current meter velocity will occur when the bobbing of a boat or cableway places the current meter into vertical motion. These errors will be significant when flowing water is < 2 ft/sec and the rate of vertical motion is > 0.3 ft/sec. (Author 's abstract)
Repeatability and oblique flow response characteristics of current meters
Fulford, Janice M.; Thibodeaux, Kirk G.; Kaehrle, William R.; ,
1993-01-01
Laboratory investigation into the precision and accuracy of various mechanical-current meters are presented. Horizontal-axis and vertical-axis meters that are used for the measurement of point velocities in streams and rivers were tested. Meters were tested for repeatability and response to oblique flows. Both horizontal- and vertical-axis meters were found to under- and over-register oblique flows with errors generally increasing as the velocity and angle of flow increased. For the oblique flow tests, magnitude of errors were smallest for horizontal-axis meters. Repeatability of all meters tested was good, with the horizontal- and vertical-axis meters performing similarly.
Code of Federal Regulations, 2010 CFR
2010-04-01
... AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER INDIAN ELECTRIC POWER UTILITIES Billing, Payments, and... determined from the register on the utility's meter at the customer's point of delivery. A reasonable estimate of the amount of energy and/or power demand may be made by the utility in the event a meter is...
A Comparative Study of the Perceived Stress of Springboard Diving by Age and Sex Groups.
ERIC Educational Resources Information Center
Ness, R. Gary
Three measures--physiological, behavioral, and phenomenological in nature--were used to register inexperienced springboard divers' perceptions of stress when faced with the execution of a forward dive from three standard heights; pool deck, one-meter and three-meter springboards. Forty-eight subjects were divided into four groups representing…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... DEPARTMENT OF THE INTERIOR National Park Service [NPS-WASO-NRNHL-10735; 2200-3200-665] National Register of Historic Places; Notification of Pending Nominations and Related Actions Nominations for the... Grain Complex, (Buffalo Grain and Materials Elevator MPS) 87 Childs St., Buffalo, 12000475 Buffalo Meter...
Four hundred meters walking test in the evaluation of heart failure patients.
Zdrenghea, D; Beudean, Maria; Pop, Dana; Zdrenghea, V
2010-01-01
The best evaluation of the severity and prognosis of heart failure patients is obtained by the maximal exercise stress testing, but for the very large number of HF patients and for evaluation of their daily effort capacity submaximal stress testing, mainly 6 minutes walking test are used. The limit of 6mWT is that during it the patients are not motivated to walk and also, the periphery, so important for heart failure patients, is not equally involved. To compare a new fixed walking test-400m walking test with 6MWT and maximal exercise testing. There were investigated 20 patients with dilated cardiomyopathy (DCM). The patients were included in the study after the relief of the congestive syndrome. Each patient was submitted in three consecutive days to a maximal symptom-limited exercise stress test on cycloergometer, a six minutes walking test, a 400 meters walking test. The last one consisted of walking on a corridor 40 meters long, at a speed chosen by the patient himself. The results were expressed in seconds representing the necessary time to cover the established 400 meters of distance. During cycloergometer exercise stress test the calculated mean peak VO2 was 15.2 +/- 1.4 mlO2/kg/min (4.32 METs). The mean distance walked during 6MWT was 350 +/- 34m and the mean time needed to walk 400m (400mWT) was 300 +/- 27 seconds. The correlation between peak VO2 and distance walked during 6MWT was -0.40, a similar but negative value (r = -0.42) being registered between peak VO2 and time registered during 400mWT. Only weak correlation was registered between LVEF and all the three tests. In turn the correlation between distance registered during 6MWT and time registered during 400mWT was excellent: r = -0.60. 400mWT is a useful tool for the evaluation of submaximal effort capacity of CHF patients. Its value to evaluate exercise capacity is similar with that of the 6 MWT, but 400mWT can assure a better evaluation of peripheral involvement.
Singh, Sarika; Mani, Kumar Vyonkesh; Kapoor, Neeru
2015-05-01
To delineate the effect of chronic electromagnetic field (EMF) exposure from radar on plasma melatonin and serotonin levels in occupationally exposed military personnel. A total of 166 male military personnel participated in the study out of which only 155 joined for blood draw. They were divided into three sets: Control group (n = 68), exposure group I (n = 40) exposed to 8-12 GHz and exposure group II (n = 58) working with radar at 12.5-18 GHz frequency. The three groups were further split into two groups according to their years of service (up to 10 years and > 10 years) in order to investigate the effect of years of exposure from radar. Melatonin and serotonin levels were estimated by enzyme immunoassay in fasting blood samples collected from 06:00-07:00 h. EMF measurements were recorded at different locations using Satimo EME Guard 'Personal Exposure Meter' and Narda 'Broad Band Field Meter'. The group I exposed population registered a minor though not significant decrease in plasma melatonin concentration while the other group II exposed population registered statistically significant decline in melatonin concentration when compared with controls. Highly significant increase in plasma serotonin levels was found in exposure group II when compared to control whereas marginal non-significant rise was also registered in exposure group I in comparison to control. Exposure in terms of length of service up to 10 years did not produce any significant effect in the indoleamine levels in both the exposure groups when they were compared with their respective control groups. Whereas, length of service greater than 10 years was observed to decrease and increase respectively the melatonin and serotonin concentration significantly in exposure group II but not in exposure group I. However, correlation test did not yield any significant association between years of service and melatonin or serotonin levels respectively in both the exposure sets I and II. No significant association was observed between melatonin and serotonin levels as well. The study showed the EMF ability to influence plasma melatonin and serotonin concentration in radar workers, significantly in 12.5-18 GHz range with service period greater than 10 years.
Harvey, Craig A.; Kolpin, Dana W.; Battaglin, William A.
1996-01-01
A geographic information system (GIS) procedure was developed to compile low-altitude aerial photography, digitized data, and land-use data from U.S. Department of Agriculture Consolidated Farm Service Agency (CFSA) offices into a high-resolution (approximately 5 meters) land-use GIS data set. The aerial photography consisted of 35-mm slides which were scanned into tagged information file format (TIFF) images. These TIFF images were then imported into the GIS where they were registered into a geographically referenced coordinate system. Boundaries between land use were delineated from these GIS data sets using on-screen digitizing techniques. Crop types were determined using information obtained from the U.S. Department of Agriculture CFSA offices. Crop information not supplied by the CFSA was attributed by manual classification procedures. Automated methods to provide delineation of the field boundaries and land-use classification were investigated. It was determined that using these data sources, automated methods were less efficient and accurate than manual methods of delineating field boundaries and classifying land use.
Advanced Mirror Technology Development (AMTD): Year Five Status
NASA Technical Reports Server (NTRS)
Stahl, H Philip
2017-01-01
The Advanced Mirror Technology Development (AMTD) project is in Phase 2 of a multiyear effort initiated in Fiscal Year (FY) 2012, to mature the Technology Readiness Level (TRL) of critical technologies required to enable 4-m-or-larger monolithic or segmented ultraviolet, optical, and infrared (UVOIR) space telescope primary-mirror assemblies for general astrophysics, ultra-high-contrast observations of exoplanets, and National Interest missions. Key accomplishments of 2016/17 include the completion of the Harris Corp approximately 150 Hz 1.5-meter Ultra-Low Expansion (ULE Registered trademark) mirror substrate using stacked core method to demonstrate lateral stability of the stacked core technology, as well as the characterization and validation by test of the mechanical and thermal performance of the 1.2-meter Zerodur (Registered trademark) mirror using the STOP model prediction and verification of CTE homogeneity.
48 CFR 52.241-6 - Service Provisions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... such errors. However, any meter which registers not more than __ percent slow or fast shall be deemed... the Government if the percentage of errors is found to be not more than __ percent slow or fast. (3...
48 CFR 52.241-6 - Service Provisions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... such errors. However, any meter which registers not more than __ percent slow or fast shall be deemed... the Government if the percentage of errors is found to be not more than __ percent slow or fast. (3...
48 CFR 52.241-6 - Service Provisions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... such errors. However, any meter which registers not more than __ percent slow or fast shall be deemed... the Government if the percentage of errors is found to be not more than __ percent slow or fast. (3...
48 CFR 52.241-6 - Service Provisions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... such errors. However, any meter which registers not more than __ percent slow or fast shall be deemed... the Government if the percentage of errors is found to be not more than __ percent slow or fast. (3...
48 CFR 52.241-6 - Service Provisions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... such errors. However, any meter which registers not more than __ percent slow or fast shall be deemed... the Government if the percentage of errors is found to be not more than __ percent slow or fast. (3...
NASA Technical Reports Server (NTRS)
Glaeser, P.; Haase, I.; Oberst, J.; Neumann, G. A.
2013-01-01
We have derived algorithms and techniques to precisely co-register laser altimeter profiles with gridded Digital Terrain Models (DTMs), typically derived from stereo images. The algorithm consists of an initial grid search followed by a least-squares matching and yields the translation parameters at sub-pixel level needed to align the DTM and the laser profiles in 3D space. This software tool was primarily developed and tested for co-registration of laser profiles from the Lunar Orbiter Laser Altimeter (LOLA) with DTMs derived from the Lunar Reconnaissance Orbiter (LRO) Narrow Angle Camera (NAC) stereo images. Data sets can be co-registered with positional accuracy between 0.13 m and several meters depending on the pixel resolution and amount of laser shots, where rough surfaces typically result in more accurate co-registrations. Residual heights of the data sets are as small as 0.18 m. The software can be used to identify instrument misalignment, orbit errors, pointing jitter, or problems associated with reference frames being used. Also, assessments of DTM effective resolutions can be obtained. From the correct position between the two data sets, comparisons of surface morphology and roughness can be made at laser footprint- or DTM pixel-level. The precise co-registration allows us to carry out joint analysis of the data sets and ultimately to derive merged high-quality data products. Examples of matching other planetary data sets, like LOLA with LRO Wide Angle Camera (WAC) DTMs or Mars Orbiter Laser Altimeter (MOLA) with stereo models from the High Resolution Stereo Camera (HRSC) as well as Mercury Laser Altimeter (MLA) with Mercury Dual Imaging System (MDIS) are shown to demonstrate the broad science applications of the software tool.
39 CFR 501.14 - Postage Evidencing System inventory control processes.
Code of Federal Regulations, 2012 CFR
2012-07-01
... affect Postal Service revenues, or of any memory component, or that affects the accuracy of the registers or the accuracy of the value printed. (7) Lost or stolen postage meter procedures—the provider must...
39 CFR 501.14 - Postage Evidencing System inventory control processes.
Code of Federal Regulations, 2013 CFR
2013-07-01
... affect Postal Service revenues, or of any memory component, or that affects the accuracy of the registers or the accuracy of the value printed. (7) Lost or stolen postage meter procedures—the provider must...
39 CFR 501.14 - Postage Evidencing System inventory control processes.
Code of Federal Regulations, 2014 CFR
2014-07-01
... affect Postal Service revenues, or of any memory component, or that affects the accuracy of the registers or the accuracy of the value printed. (7) Lost or stolen postage meter procedures—the provider must...
MOLA-Based Landing Site Characterization
NASA Technical Reports Server (NTRS)
Duxbury, T. C.; Ivanov, A. B.
2001-01-01
The Mars Global Surveyor (MGS) Mars Orbiter Laser Altimeter (MOLA) data provide the basis for site characterization and selection never before possible. The basic MOLA information includes absolute radii, elevation and 1 micrometer albedo with derived datasets including digital image models (DIM's illuminated elevation data), slopes maps and slope statistics and small scale surface roughness maps and statistics. These quantities are useful in downsizing potential sites from descent engineering constraints and landing/roving hazard and mobility assessments. Slope baselines at the few hundred meter level and surface roughness at the 10 meter level are possible. Additionally, the MOLA-derived Mars surface offers the possibility to precisely register and map project other instrument datasets (images, ultraviolet, infrared, radar, etc.) taken at different resolution, viewing and lighting geometry, building multiple layers of an information cube for site characterization and selection. Examples of direct MOLA data, data derived from MOLA and other instruments data registered to MOLA arc given for the Hematite area.
Simplified Processing Method for Meter Data Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, Kimberly M.; Colotelo, Alison H. A.; Downs, Janelle L.
2015-11-01
Simple/Quick metered data processing method that can be used for Army Metered Data Management System (MDMS) and Logistics Innovation Agency data, but may also be useful for other large data sets. Intended for large data sets when analyst has little information about the buildings.
Predicted blood glucose from insulin administration based on values from miscoded glucose meters.
Raine, Charles H; Pardo, Scott; Parkes, Joan Lee
2008-07-01
The proper use of many types of self-monitored blood glucose (SMBG) meters requires calibration to match strip code. Studies have demonstrated the occurrence and impact on insulin dose of coding errors with SMBG meters. This paper reflects additional analyses performed with data from Raine et al. (JDST, 2:205-210, 2007). It attempts to relate potential insulin dose errors to possible adverse blood glucose outcomes when glucose meters are miscoded. Five sets of glucose meters were used. Two sets of meters were autocoded and therefore could not be miscoded, and three sets required manual coding. Two of each set of manually coded meters were deliberately miscoded, and one from each set was properly coded. Subjects (n = 116) had finger stick blood glucose obtained at fasting, as well as at 1 and 2 hours after a fixed meal (Boost((R)); Novartis Medical Nutrition U.S., Basel, Switzerland). Deviations of meter blood glucose results from the reference method (YSI) were used to predict insulin dose errors and resultant blood glucose outcomes based on these deviations. Using insulin sensitivity data, it was determined that, given an actual blood glucose of 150-400 mg/dl, an error greater than +40 mg/dl would be required to calculate an insulin dose sufficient to produce a blood glucose of less than 70 mg/dl. Conversely, an error less than or equal to -70 mg/dl would be required to derive an insulin dose insufficient to correct an elevated blood glucose to less than 180 mg/dl. For miscoded meters, the estimated probability to produce a blood glucose reduction to less than or equal to 70 mg/dl was 10.40%. The corresponding probabilities for autocoded and correctly coded manual meters were 2.52% (p < 0.0001) and 1.46% (p < 0.0001), respectively. Furthermore, the errors from miscoded meters were large enough to produce a calculated blood glucose outcome less than or equal to 50 mg/dl in 42 of 833 instances. Autocoded meters produced zero (0) outcomes less than or equal to 50 mg/dl out of 279 instances, and correctly coded manual meters produced 1 of 416. Improperly coded blood glucose meters present the potential for insulin dose errors and resultant clinically significant hypoglycemia or hyperglycemia. Patients should be instructed and periodically reinstructed in the proper use of blood glucose meters, particularly for meters that require coding.
NASA Technical Reports Server (NTRS)
Abdel-Gawad, M. (Principal Investigator)
1975-01-01
The author has identified the following significant results. Surface indications of recent faulting are generally observed in EREP S190B photographs. Comparison of secondary roads (asphalt and dirt) registered in EREP and U-2 photographs together with field measurements shows that dirt and asphalt roads about seven meters wide can be detected in EREP S190B photographs where sufficient contrast exists between the tone of the road surface and surrounding terrain. In low contrast cases, roads more than ten meters wide could not be detected.
Capillary glucose meter accuracy and sources of error in the ambulatory setting.
Lunt, Helen; Florkowski, Christopher; Bignall, Michael; Budgen, Christopher
2010-03-05
Hand-held glucose meters are used throughout the health system by both patients with diabetes and also by health care practitioners. Glucose meter technology is constantly evolving. The current generation of meters and strips are quick to use and require a very small volume of blood. This review aims to describe meters currently available in New Zealand, for use in the ambulatory setting. It also aims to discuss the limits of meter performance and provide technical information that is relevant to the clinician, using locally available data. Commoner causes and consequences of end-user (patient and health professional) error are illustrated using clinical case examples. No meter offers definite advantages over other meters in all clinical situations, rather meters should be chosen because they fit the needs of individual patients and because the provider is able to offer appropriate educational and quality assurance backup to the meter user. A broad understanding of the advantages and disadvantages of the subsidised meter systems available in New Zealand will help the health practitioner decide when it is in the best interests of their patients to change or update meter technology.
Predicted Blood Glucose from Insulin Administration Based on Values from Miscoded Glucose Meters
Raine, Charles H.; Pardo, Scott; Parkes, Joan Lee
2008-01-01
Objectives The proper use of many types of self-monitored blood glucose (SMBG) meters requires calibration to match strip code. Studies have demonstrated the occurrence and impact on insulin dose of coding errors with SMBG meters. This paper reflects additional analyses performed with data from Raine et al. (JDST, 2:205–210, 2007). It attempts to relate potential insulin dose errors to possible adverse blood glucose outcomes when glucose meters are miscoded. Methods Five sets of glucose meters were used. Two sets of meters were autocoded and therefore could not be miscoded, and three sets required manual coding. Two of each set of manually coded meters were deliberately miscoded, and one from each set was properly coded. Subjects (n = 116) had finger stick blood glucose obtained at fasting, as well as at 1 and 2 hours after a fixed meal (Boost®; Novartis Medical Nutrition U.S., Basel, Switzerland). Deviations of meter blood glucose results from the reference method (YSI) were used to predict insulin dose errors and resultant blood glucose outcomes based on these deviations. Results Using insulin sensitivity data, it was determined that, given an actual blood glucose of 150–400 mg/dl, an error greater than +40 mg/dl would be required to calculate an insulin dose sufficient to produce a blood glucose of less than 70 mg/dl. Conversely, an error less than or equal to -70 mg/dl would be required to derive an insulin dose insufficient to correct an elevated blood glucose to less than 180 mg/dl. For miscoded meters, the estimated probability to produce a blood glucose reduction to less than or equal to 70 mg/dl was 10.40%. The corresponding probabilities for autocoded and correctly coded manual meters were 2.52% (p < 0.0001) and 1.46% (p < 0.0001), respectively. Furthermore, the errors from miscoded meters were large enough to produce a calculated blood glucose outcome less than or equal to 50 mg/dl in 42 of 833 instances. Autocoded meters produced zero (0) outcomes less than or equal to 50 mg/dl out of 279 instances, and correctly coded manual meters produced 1 of 416. Conclusions Improperly coded blood glucose meters present the potential for insulin dose errors and resultant clinically significant hypoglycemia or hyperglycemia. Patients should be instructed and periodically reinstructed in the proper use of blood glucose meters, particularly for meters that require coding. PMID:19885229
Scintillation probe with photomultiplier tube saturation indicator
Ruch, Jeffrey F.; Urban, David J.
1996-01-01
A photomultiplier tube saturation indicator is formed by supplying a supplemental light source, typically an light emitting diode (LED), adjacent to the photomultiplier tube. A switch allows the light source to be activated. The light is forwarded to the photomultiplier tube by an optical fiber. If the probe is properly light tight, then a meter attached to the indicator will register the light from the LED. If the probe is no longer light tight, and the saturation indicator is saturated, no signal will be registered when the LED is activated.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-04
... 32 CFR Part 706 Marine Safety, Navigation (Water), and Vessels. For the reasons set forth in the... dk masthead ship's keel in flight dk Rule in meters; Rule in meters; light in sides in meters; in meters; 30(a)(i) Rule 21(e), 30(a)(ii) Sec. 2 meters; meters; Rule 21(a) Sec. Rule (g), Annex Sec. Sec. 2...
Mancini, Alessio; Esposto, Giampaolo; Manfrini, Silvana; Rilli, Silvia; Tinti, Gessica; Carta, Giuseppe; Petrolati, Laura; Vidali, Matteo; Barocci, Simone
2018-05-01
The aim of this retrospective study is to evaluate the reliability and robustness of six glucose meters for point-of-care testing in our wards using a brand-new protocol. During a 30-days study period a total of 50 diabetes patients were subjected to venous blood sampling and glucose meter blood analysis. The results of six glucose meters were compared with our laboratory reference assay. GlucoMen Plus (Menarini) with the 82% of acceptable results was the most robust glucose meter. Even if the Passing-Bablok analysis demonstrates the presence of constant systematic errors and the Bland-Altman test highlighted a possible overestimation, the surveillance error grid analysis showed that this glucose meter can be used safely. We proved that portable glucose meters are not always reliable in routinely clinical settings.
Muscle strength at the trunk*.
Smidt, G L; Amundsen, L R; Dostal, W F
1980-01-01
The purpose of this study was to determine the strength of trunk flexors and extensors in normal male subjects during isometric, concentric, and eccentric contractions. Subjects were tested in the sidelying position to minimize the effects of gravity. The pelvis and lower extremities were measured on a custom built force table (lowa Force Table). Muscle strength was expressed as a moment of force (external force times the moment arm) in Newton-meter (Nm) units. Greater Nm were registered in the muscle-lengthened position than in the muscle-shortened position for all isometric contractions. The Nm registered for eccentric contractions always exceeded the Nm registered for concentric contractions of the same muscle group. The Nm registered during contractions of trunk extensors always exceeded the values obtained during corresponding modes of contractions (isometric, eccentric, and concentric) of trunk flexors.J Orthop Sports Phys Ther 1980;1(3):165-170.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-08
... safety, Navigation (water), and Vessels. For the reasons set forth in the preamble, the Navy amends part... meters; Rule in meters; light in sides in meters; in meters; (i) Rule 21(e), 30(a)(ii) Sec. meters; meters; Rule 21(a) Sec. Rule 2(g), Annex Sec. Sec. 2(K), 30(a)(ii) I 3(b), Annex 3(b), Annex Annex I I I...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-05
... 32 CFR Part 706 Marine safety, Navigation (water), and Vessels. For the reasons set forth in the... stbd of keel dk in number of; dk in Rule meters; Sec. light in in meters; in meters; meters; Sec. Rule meters; Rule 30(a)(ii) 2(g), meters; Sec. Sec. 3(b), Rule 21(a) 2(K), 30(a)(i) 21(e), Rule Annex I 3(b...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-09
..., Navigation (water), and Vessels. For the reasons set forth in the preamble, the Navy amends part 706 of title... masthead ship's keel in in number of; in meters; Rule 30(a) in light in sides in meters; meters; Rule 30(a) Rule (ii) meters; meters; meters; Rule 21(a) Sec. (i) 21(e), Sec. 2 Sec. Sec. 2(K), Rule (g), Annex 3(b...
Zhang, Ray; Isakow, Warren; Kollef, Marin H; Scott, Mitchell G
2017-09-01
Due to accuracy concerns, the Food and Drug Administration issued guidances to manufacturers that resulted in Center for Medicare and Medicaid Services stating that the use of meters in critically ill patients is "off-label" and constitutes "high complexity" testing. This is causing significant workflow problems in ICUs nationally. We wished to determine whether real-world accuracy of modern glucose meters is worse in ICU patients compared with non-ICU inpatients. We reviewed glucose results over the preceding 3 years, comparing results from paired glucose meter and central laboratory tests performed within 60 minutes of each other in ICU versus non-ICU settings. Seven ICU and 30 non-ICU wards at a 1,300-bed academic hospital in the United States. A total of 14,763 general medicine/surgery inpatients and 20,970 ICU inpatients. None. Compared meter results with near simultaneously performed laboratory results from the same patient by applying the 2016 U.S. Food and Drug Administration accuracy criteria, determining mean absolute relative difference and examining where paired results fell within the Parkes consensus error grid zones. A higher percentage of glucose meter results from ICUs than from non-ICUs passed 2016 Food and Drug Administration accuracy criteria (p < 10) when comparing meter results with laboratory results. At 1 minute, no meter result from ICUs posed dangerous or significant risk by error grid analysis, whereas at 10 minutes, less than 0.1% of ICU meter results did, which was not statistically different from non-ICU results. Real-world accuracy of modern glucose meters is at least as accurate in the ICU setting as in the non-ICU setting at our institution.
Sohl, Terry L.; Dwyer, John L.
1998-01-01
The North American Landscape Characterization (NALC) project is a component of the National Aeronautics and Space Administration (NASA) Landsat Pathfinder program. Pathfinder projects are focused on the investigation of global change utilizing current remote sensing technologies. The NALC project is a cooperative effort between the U. S. Environmental Protection Agency (EPA), the U.S. Geological Survey (USGS), and NASA to make Landsat data available to the widest possible user community for scientific research and general public interest. The NALC project is principally funded by the EPA Office of Research and Development and the USGS's Earth Resources Observation Systems (EROS) Data Center (EDC).The objectives of the NALC project are to produce standardized remote sensing data sets, develop standardized analysis methods, and derive standardized land cover change products for a large portion of the North American continent (the conterminous United States and Mexico) (Lunetta and Sturdevant, 1993). The standard product is the NALC “triplicate”;, consisting of co‐registered Landsat multispectral scanner data for the years 1973, 1986, and 1991 (plus or minus one year), plus co‐registered 3 arcsecond digital terrain elevation data. Processing began with the 1986 scene, which was precision corrected (with full terrain correction) to a 60 meter Universal Transverse Mercator base. Automated cross‐correlation procedures were used to co‐register the 1970's and 1990's data to the 1980's base, and independent verifications of registration quality were performed on all triplicate components. The pertinent metadata were compiled in a relational database, which includes WRS2 path/rows, scene ID's, image dates, solar azimuth and elevation, verification RMSE's, and the number of verification control points. NALC triplicate data sets are being used for a number of applications, including the analysis of urbanization patterns, dynamics of climatic fluctuations, deforestation studies, and vegetation classification and mapping. These data are being distributed through the Earth Observing System Data and Information System (EOSDIS) Information Management System (IMS) at a cost of $15(U.S.) for each triplicate.
Defense Automation Resources Management Manual
1988-09-01
Electronic Command Signals Programmer, Plugboard Programmers Punch, Card Punch, Paper Tape Reader, Character Reader-Generator, Time Cards Reader...Multiplexor-Shift Register Group Multiplier Panel Control, Plugboard Panel, Interconnection, Digital Computer Panel, Meter-Attenuator, Tape Recorder PC Cards...Perforator, Tape Plug-In Unit Potentiometer, Coefficient, Analog Computer Programmer, Plugboard Punch, Paper Tape Racks Reader, Time Code Reader
Ham, Melissa R; Okada, Pamela; White, Perrin C
2004-03-01
Diabetic ketoacidosis (DKA) is a serious complication of diabetes mellitus marked by characteristic biochemical derangements. Diagnosis and management involve frequent evaluation of these biochemical parameters. Reliable bedside equivalents for these laboratory studies may help reduce the time to treatment and reduce costs. We evaluated the precision and bias of a bedside serum ketone meter in the acute care setting. Serum ketone results using the Precision Xtra glucometer/ketone meter (Abbott Laboratories, MediSense Products Inc., Bedford, MA, USA) correlated strongly with the Children's Medical Center of Dallas' laboratory values within the meter's value range. Meter ketone values steadily decreased during the treatment of DKA as pH and CO(2) levels increased and acidosis resolved. Therefore, the meter may be useful in monitoring therapy for DKA. This meter may also prove useful in identifying patients at risk for DKA in physicians' offices or at home.
Overcoming Spatial and Temporal Barriers to Public Access Defibrillators Via Optimization
Sun, Christopher L. F.; Demirtas, Derya; Brooks, Steven C.; Morrison, Laurie J.; Chan, Timothy C.Y.
2016-01-01
BACKGROUND Immediate access to an automated external defibrillator (AED) increases the chance of survival from out-of-hospital cardiac arrest (OHCA). Current deployment usually considers spatial AED access, assuming AEDs are available 24 h a day. OBJECTIVES We sought to develop an optimization model for AED deployment, accounting for spatial and temporal accessibility, to evaluate if OHCA coverage would improve compared to deployment based on spatial accessibility alone. METHODS This was a retrospective population-based cohort study using data from the Toronto Regional RescuNET cardiac arrest database. We identified all nontraumatic public-location OHCAs in Toronto, Canada (January 2006 through August 2014) and obtained a list of registered AEDs (March 2015) from Toronto emergency medical services. We quantified coverage loss due to limited temporal access by comparing the number of OHCAs that occurred within 100 meters of a registered AED (assumed 24/7 coverage) with the number that occurred both within 100 meters of a registered AED and when the AED was available (actual coverage). We then developed a spatiotemporal optimization model that determined AED locations to maximize OHCA actual coverage and overcome the reported coverage loss. We computed the coverage gain between the spatiotemporal model and a spatial-only model using 10-fold cross-validation. RESULTS We identified 2,440 atraumatic public OHCAs and 737 registered AED locations. A total of 451 OHCAs were covered by registered AEDs under assumed 24/7 coverage, and 354 OHCAs under actual coverage, representing a coverage loss of 21.5% (p < 0.001). Using the spatiotemporal model to optimize AED deployment, a 25.3% relative increase in actual coverage was achieved over the spatial-only approach (p < 0.001). CONCLUSIONS One in 5 OHCAs occurred near an inaccessible AED at the time of the OHCA. Potential AED use was significantly improved with a spatiotemporal optimization model guiding deployment. PMID:27539176
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-24
..., Navigation (water), and Vessels. 0 For the reasons set forth in the preamble, the DoN amends part 706 of... above hull light in meters 2(K) rule 21(a) rule 21(b) rule 21(c) meters meters; in meters; annex 1 3(b... when tow exceeds 200 meters from the stern of the ship to aft end of tow. Approved: September 8, 2010...
Ojeda, Álvaro Huerta; Ríos, Luis Chirosa; Barrilao, Rafael Guisado; Serrano, Pablo Cáceres
2016-01-01
[Purpose] The aim of this study was to determine the acute effect temporal of a complex training protocol on 30 meter sprint times. A secondary objective was to evaluate the fatigue indexes of military athletes. [Subjects and Methods] Seven military athletes were the subjects of this study. The variables measured were times in 30-meter sprint, and average power and peak power of squats. The intervention session with complex training consisted of 4 sets of 5 repetitions at 30% 1RM + 4 repetitions at 60% 1RM + 3 repetitions of 30 meters with 120-second rests. For the statistical analysis repeated measures of ANOVA was used, and for the post hoc analysis, student’s t-test was used. [Results] Times in 30 meter sprints showed a significant reduction between the control set and the four experimental sets, but the average power and peak power of squats did not show significant changes. [Conclusion] The results of the study show the acute positive effect of complex training, over time, in 30-meter sprint by military athletes. This effect is due to the post activation potentiation of the lower limbs’ muscles in the 30 meters sprint. PMID:27134353
Ojeda, Álvaro Huerta; Ríos, Luis Chirosa; Barrilao, Rafael Guisado; Serrano, Pablo Cáceres
2016-03-01
[Purpose] The aim of this study was to determine the acute effect temporal of a complex training protocol on 30 meter sprint times. A secondary objective was to evaluate the fatigue indexes of military athletes. [Subjects and Methods] Seven military athletes were the subjects of this study. The variables measured were times in 30-meter sprint, and average power and peak power of squats. The intervention session with complex training consisted of 4 sets of 5 repetitions at 30% 1RM + 4 repetitions at 60% 1RM + 3 repetitions of 30 meters with 120-second rests. For the statistical analysis repeated measures of ANOVA was used, and for the post hoc analysis, student's t-test was used. [Results] Times in 30 meter sprints showed a significant reduction between the control set and the four experimental sets, but the average power and peak power of squats did not show significant changes. [Conclusion] The results of the study show the acute positive effect of complex training, over time, in 30-meter sprint by military athletes. This effect is due to the post activation potentiation of the lower limbs' muscles in the 30 meters sprint.
Intravenous fluid flow meter concept for zero gravity environment
NASA Technical Reports Server (NTRS)
Miller, C. G.
1972-01-01
Measuring chamber, included in infusion-set tubing, and peristaltic flow meter concept can be incorporated into flow meter that measures fluid flow rates between 100 and 600 cu cm per hour and at the same time maintains sterilization.
Global detailed geoid computation and model analysis
NASA Technical Reports Server (NTRS)
Marsh, J. G.; Vincent, S.
1974-01-01
Comparisons and analyses were carried out through the use of detailed gravimetric geoids which we have computed by combining models with a set of 26,000 1 deg x 1 deg mean free air gravity anomalies. The accuracy of the detailed gravimetric geoid computed using the most recent Goddard earth model (GEM-6) in conjunction with the set of 1 deg x 1 deg mean free air gravity anomalies is assessed at + or - 2 meters on the continents of North America, Europe, and Australia, 2 to 5 meters in the Northeast Pacific and North Atlantic areas, and 5 to 10 meters in other areas where surface gravity data are sparse. The R.M.S. differences between this detailed geoid and the detailed geoids computed using the other satellite gravity fields in conjuction with same set of surface data range from 3 to 7 meters.
Walking adaptability therapy after stroke: study protocol for a randomized controlled trial.
Timmermans, Celine; Roerdink, Melvyn; van Ooijen, Marielle W; Meskers, Carel G; Janssen, Thomas W; Beek, Peter J
2016-08-26
Walking in everyday life requires the ability to adapt walking to the environment. This adaptability is often impaired after stroke, and this might contribute to the increased fall risk after stroke. To improve safe community ambulation, walking adaptability training might be beneficial after stroke. This study is designed to compare the effects of two interventions for improving walking speed and walking adaptability: treadmill-based C-Mill therapy (therapy with augmented reality) and the overground FALLS program (a conventional therapy program). We hypothesize that C-Mill therapy will result in better outcomes than the FALLS program, owing to its expected greater amount of walking practice. This is a single-center parallel group randomized controlled trial with pre-intervention, post-intervention, retention, and follow-up tests. Forty persons after stroke (≥3 months) with deficits in walking or balance will be included. Participants will be randomly allocated to either C-Mill therapy or the overground FALLS program for 5 weeks. Both interventions will incorporate practice of walking adaptability and will be matched in terms of frequency, duration, and therapist attention. Walking speed, as determined by the 10 Meter Walking Test, will be the primary outcome measure. Secondary outcome measures will pertain to walking adaptability (10 Meter Walking Test with context or cognitive dual-task and Interactive Walkway assessments). Furthermore, commonly used clinical measures to determine walking ability (Timed Up-and-Go test), walking independence (Functional Ambulation Category), balance (Berg Balance Scale), and balance confidence (Activities-specific Balance Confidence scale) will be used, as well as a complementary set of walking-related assessments. The amount of walking practice (the number of steps taken per session) will be registered using the treadmill's inbuilt step counter (C-Mill therapy) and video recordings (FALLS program). This process measure will be compared between the two interventions. This study will assess the effects of treadmill-based C-Mill therapy compared with the overground FALLS program and thereby the relative importance of the amount of walking practice as a key aspect of effective intervention programs directed at improving walking speed and walking adaptability after stroke. Netherlands Trial Register NTR4030 . Registered on 11 June 2013, amendment filed on 17 June 2016.
Moisture meter calibration for untreated and ACQ-treated southern yellow pine plywood
Samuel V. Glass; Charles G. Carll
2009-01-01
Conductance moisture meter readings using stainless steel screws as electrodes were compared with gravimetric moisture content for 1) southern yellow pine (SYP) dimensioned lumber, 2) untreated (underlayment grade) SYP plywood, and 3) SYP plywood treated with alkaline copper quaternary. Meter readings were taken with the meter set to the manufacturer-provided species...
Rebeiro, Geraldine; Edward, Karen-leigh; Chapman, Rose; Evans, Alicia
2015-12-01
A significant proportion of undergraduate nursing education occurs in the clinical setting in the form of practising skills and competencies, and is a requirement of all nursing curriculum for registration to practice. Education in the clinical setting is facilitated by registered nurses, yet this interpersonal relationship has not been examined well. To investigate the experience of interpersonal relationships between registered nurses and student nurses in the clinical setting from the point of view of the registered nurse. Integrative review Review methods: The databases of MEDLINE, CINAHL and OVID were searched. Key words used included: Registered Nurse, Preceptor, Buddy Nurse, Clinical Teacher, Mentor, Student Nurse, Nursing Student, Interpersonal Relationships, Attitudes and Perceptions. Additional review of the literature was manually undertaken through university library textbooks. 632 abstracts were returned after duplicates were removed. Twenty one articles were identified for full text read (quantitative n=2, mixed n=6, qualitative n=14); of these, seven articles addressed the experience of interpersonal relationships between registered nurses and student nurses in the clinical setting from the point of view of the registered nurse and these were reviewed. Providing education for registered nurses to enable them to lead student education in the clinical setting communicates the organizational value of the role. Registered nurses identified being supported in having the time-to-teach were considered important in facilitation of the clinical teaching role. The integrative review did not provide evidence related to the impact diverse clinical settings can have on the relationships between registered nurses and student nurses revealing an area for further examination. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Perkins, David Nikolaus; Gonzales, Antonio I
2014-04-08
A set of co-registered coherent change detection (CCD) products is produced from a set of temporally separated synthetic aperture radar (SAR) images of a target scene. A plurality of transformations are determined, which transformations are respectively for transforming a plurality of the SAR images to a predetermined image coordinate system. The transformations are used to create, from a set of CCD products produced from the set of SAR images, a corresponding set of co-registered CCD products.
NASA Astrophysics Data System (ADS)
Arvesen, J. C.; Dotson, R. C.
2014-12-01
The DMS (Digital Mapping System) has been a sensor component of all DC-8 and P-3 IceBridge flights since 2009 and has acquired over 3 million JPEG images over Arctic and Antarctic land and sea ice. The DMS imagery is primarily used for identifying and locating open leads for LiDAR sea-ice freeboard measurements and documenting snow and ice surface conditions. The DMS is a COTS Canon SLR camera utilizing a 28mm focal length lens, resulting in a 10cm GSD and swath of ~400 meters from a nominal flight altitude of 500 meters. Exterior orientation is provided by an Applanix IMU/GPS which records a TTL pulse coincident with image acquisition. Notable for virtually all IceBridge flights is that parallel grids are not flown and thus there is no ability to photogrammetrically tie any imagery to adjacent flight lines. Approximately 800,000 Level-3 DMS Surface Model data products have been delivered to NSIDC, each consisting of a Digital Elevation Model (GeoTIFF DEM) and a co-registered Visible Overlay (GeoJPEG). Absolute elevation accuracy for each individual Elevation Model is adjusted to concurrent Airborne Topographic Mapper (ATM) Lidar data, resulting in higher elevation accuracy than can be achieved by photogrammetry alone. The adjustment methodology forces a zero mean difference to the corresponding ATM point cloud integrated over each DMS frame. Statistics are calculated for each DMS Elevation Model frame and show RMS differences are within +/- 10 cm with respect to the ATM point cloud. The DMS Surface Model possesses similar elevation accuracy to the ATM point cloud, but with the following advantages: · Higher and uniform spatial resolution: 40 cm GSD · 45% wider swath: 435 meters vs. 300 meters at 500 meter flight altitude · Visible RGB co-registered overlay at 10 cm GSD · Enhanced visualization through 3-dimensional virtual reality (i.e. video fly-through) Examples will be presented of the utility of these advantages and a novel use of a cell phone camera for aerial photogrammetry will also be presented.
The AGS Ggamma Meter and Calibrating the Gauss Clock
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahrens, Leif
2014-03-31
During AGS Polarized Proton acceleration periods, one output from the AGS Ggamma Meter, namely the energy (or Ggamma) calculated from the magnetic field in the AGS main magnets and the beam radius- both measured in particular instant, is used to figure out the times in the AGS magnet acceleration cycle when the beam passes through a particular set of depolarizing resonances. The resonance set occur whenever a particle’s Ggamma (energy*(G/m) becomes nearly equal to n*Qx (i.e. any integer multiplied by the horizontal betatron tune). This deliverable is why the machinery is referred to as the ''Ggamma Meter'' rather than themore » AGS energy meter. The Ggamma Meter takes as inputs a set of measurements of frequency (F(t)), radius (r(t)), and gauss clock counts (GCC(t)). The other energy (GgammaBr) assumes the field when the gauss clock starts counting is known. The change in field to time t is given by the measured accumulated gauss clock counts multiplied by the gauss clock calibration (gauss/GCC). In order to deal with experimental data, this calibration factor gets an added ad hoc complication, namely a correction dependent on the rate of change the counting rate. The Ggamma meter takes GCC(t) and together with the past history for this cycle calculates B(t).« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-15
... safety, Navigation (water), and Vessels. For the reasons set forth in the preamble, amend part 706 of... sides stern in hull in forward light in rule 21(a) rule 21(b) rule 21(c) in meters meters; rule meters; 2(k) meters 2(k) 3(b) Annex 1 21(c) Annex 1 Annex 1 * * * * * * * USS SOMERSET LPD 25 1.64 below...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-30
... safety, Navigation (water), and Vessels. For the reasons set forth in the preamble, amend part 706 of... forward Vessel No. visibility; visibility; visibility; ship's sides stern in above hull in light in meters 2(k) Annex rule 21(a) rule 21(b) rule 21(c) in meters 3(b) meters; rule meters; 2(k) 1 Annex 1 21(c...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-30
... CFR Part 706 Marine safety, Navigation (water), and Vessels. For the reasons set forth in the preamble... stern in above hull in light in meters 2(k) Annex rule 21(a) rule 21(b) rule 21(c) in meters 3(b) meters; rule meters; 2(k) 1 Annex 1 21(c) Annex 1 * * * * * * * USS ANCHORAGE LPD 23 1.19 below...
A Prototype Two-Level Multicomputer Study
1999-01-01
Wakeup : When this input is asserted, the wakeJnt bit in the special register ISR (Interrupt Status Register) is set. 43 MYRINET SAN INTERFACE Pin...including the double-word pointed to by RMC, the headJnt bit of ISR is set (page 10). RMW Receive-Message Header Wakeup : This is the same physical register...Register) are both equal to 1. WAKE synch. I Wakeup : When this input is asserted, the wakeJnt bit in the special register ISR (Interrupt Status
El Hussein, Mohamed; Hirst, Sandra
2016-02-01
To construct a grounded theory that explains the clinical reasoning processes that registered nurses use to recognise delirium while caring for older adults in acute care settings. Delirium is often under-recognised in acute care settings; this may stem from underdeveloped clinical reasoning processes. Little is known about registered nurses' clinical reasoning processes in complex situations such as delirium recognition. Seventeen registered nurses working in acute care settings were interviewed. Concurrent data collection and analysis, constant comparative analysis and theoretical sampling were conducted in 2013-2014. A grounded theory approach was used to analyse interview data about the clinical reasoning processes of registered nurse in acute hospital settings. The core category that emerged from data was 'Tracking the footsteps'. This refers to the common clinical reasoning processes that registered nurses in this study used to recognise delirium in older adults in acute care settings. It depicted the process of continuously trying to catch the state of delirium in older adults. Understanding the clinical reasoning processes that contribute to delirium under-recognition provides a strategy by which this problem can be brought to the forefront of awareness and intervention by registered nurses. Registered nurses could draw from the various processes identified in this research to develop their clinical reasoning practice to enhance their effective assessment strategies. Delirium recognition by registered nurses will contribute to quality care to older adults. © 2016 John Wiley & Sons Ltd.
Overcoming Spatial and Temporal Barriers to Public Access Defibrillators Via Optimization.
Sun, Christopher L F; Demirtas, Derya; Brooks, Steven C; Morrison, Laurie J; Chan, Timothy C Y
2016-08-23
Immediate access to an automated external defibrillator (AED) increases the chance of survival for out-of-hospital cardiac arrest (OHCA). Current deployment usually considers spatial AED access, assuming AEDs are available 24 h a day. The goal of this study was to develop an optimization model for AED deployment, accounting for spatial and temporal accessibility, to evaluate if OHCA coverage would improve compared with deployment based on spatial accessibility alone. This study was a retrospective population-based cohort trial using data from the Toronto Regional RescuNET Epistry cardiac arrest database. We identified all nontraumatic public location OHCAs in Toronto, Ontario, Canada (January 2006 through August 2014) and obtained a list of registered AEDs (March 2015) from Toronto Paramedic Services. Coverage loss due to limited temporal access was quantified by comparing the number of OHCAs that occurred within 100 meters of a registered AED (assumed coverage 24 h per day, 7 days per week) with the number that occurred both within 100 meters of a registered AED and when the AED was available (actual coverage). A spatiotemporal optimization model was then developed that determined AED locations to maximize OHCA actual coverage and overcome the reported coverage loss. The coverage gain between the spatiotemporal model and a spatial-only model was computed by using 10-fold cross-validation. A total of 2,440 nontraumatic public OHCAs and 737 registered AED locations were identified. A total of 451 OHCAs were covered by registered AEDs under assumed coverage 24 h per day, 7 days per week, and 354 OHCAs under actual coverage, representing a coverage loss of 21.5% (p < 0.001). Using the spatiotemporal model to optimize AED deployment, a 25.3% relative increase in actual coverage was achieved compared with the spatial-only approach (p < 0.001). One in 5 OHCAs occurred near an inaccessible AED at the time of the OHCA. Potential AED use was significantly improved with a spatiotemporal optimization model guiding deployment. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Geerse, Daphne J; Coolen, Bert H; Roerdink, Melvyn
2015-01-01
Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point's time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point's time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters' walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman's bias and limits of agreement. Body point's time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point's time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner.
Geerse, Daphne J.; Coolen, Bert H.; Roerdink, Melvyn
2015-01-01
Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect’s 3D body point’s time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point’s time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point’s time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters’ walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman’s bias and limits of agreement. Body point’s time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point’s time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner. PMID:26461498
OCCUPATIONAL EXPOSURE OF NMR SPECTROMETRISTS TO STATIC AND RADIOFREQUENCY FIELDS.
Berlana, Tania; Úbeda, Alejandro
2017-12-01
Occupational exposure to static and radiofrequency fields emitted by nuclear magnetic resonance spectrometers was assessed through systematic field metering during operation of 19 devices in nine research centers. Whereas no measurable levels of radiofrequency radiation were registered outside the spectrometers, significant exposure to static field was detected, with maximum values recorded at the user's hand (B = 683.00 mT) and head-thorax (B = 135.70 mT) during spectrometer manipulation. All values were well below the exposure limits set by the European standard for workers protection against the effects of acute field exposure only. As for potential effects of chronic exposure, waiting for more complete knowledge, adoption of technical and operational strategies for exposure minimizing is advisable. In this respect, the data revealed that compared with standard magnetic shielding, ultrashield technology allows a 20-65-fold reduction of the field strength received by the operator. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
The Early Development of Electronic pH Meters
ERIC Educational Resources Information Center
Hines, Wallis G.; de Levie, Robert
2010-01-01
A 19-year-old undergraduate at the University of Chicago, Kenneth Goode, in 1921 came up with the idea of an electronic pH meter, worked out some of its initial problems, and set in motion an international scientific effort that culminated in the current, wide availability of electronic pH meters. Except for the replacement of vacuum tubes by…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-24
... longline hooks fish deeper than 100 meters (m) to reduce interactions with Pacific green sea turtles. This... to configure their fishing gear so that longline hooks are set to fish deeper than 100 meters, away... 40 ft to use float lines that are at least 30 meters long, and maintain a distance between float...
Processing Device for High-Speed Execution of an Xrisc Computer Program
NASA Technical Reports Server (NTRS)
Ng, Tak-Kwong (Inventor); Mills, Carl S. (Inventor)
2016-01-01
A processing device for high-speed execution of a computer program is provided. A memory module may store one or more computer programs. A sequencer may select one of the computer programs and controls execution of the selected program. A register module may store intermediate values associated with a current calculation set, a set of output values associated with a previous calculation set, and a set of input values associated with a subsequent calculation set. An external interface may receive the set of input values from a computing device and provides the set of output values to the computing device. A computation interface may provide a set of operands for computation during processing of the current calculation set. The set of input values are loaded into the register and the set of output values are unloaded from the register in parallel with processing of the current calculation set.
Two laboratory methods for the calibration of GPS speed meters
NASA Astrophysics Data System (ADS)
Bai, Yin; Sun, Qiao; Du, Lei; Yu, Mei; Bai, Jie
2015-01-01
The set-ups of two calibration systems are presented to investigate calibration methods of GPS speed meters. The GPS speed meter calibrated is a special type of high accuracy speed meter for vehicles which uses Doppler demodulation of GPS signals to calculate the measured speed of a moving target. Three experiments are performed: including simulated calibration, field-test signal replay calibration, and in-field test comparison with an optical speed meter. The experiments are conducted at specific speeds in the range of 40-180 km h-1 with the same GPS speed meter as the device under calibration. The evaluation of measurement results validates both methods for calibrating GPS speed meters. The relative deviations between the measurement results of the GPS-based high accuracy speed meter and those of the optical speed meter are analyzed, and the equivalent uncertainty of the comparison is evaluated. The comparison results justify the utilization of GPS speed meters as reference equipment if no fewer than seven satellites are available. This study contributes to the widespread use of GPS-based high accuracy speed meters as legal reference equipment in traffic speed metrology.
Results of the long range position-determining system tests. [Field Army system
NASA Technical Reports Server (NTRS)
Rhode, F. W.
1973-01-01
The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.
Quantifying exchange between groundwater and surface water in rarely measured organic sediments
NASA Astrophysics Data System (ADS)
Rosenberry, D. O.; Cavas, M.; Keith, D.; Gefell, M. J.; Jones, P. M.
2016-12-01
Transfer of water and chemicals between poorly competent organic sediments and surface water in low-energy riverine and lentic settings depends on several factors, including rate and direction of flow, redox state, number and type of benthic invertebrates, and chemical gradients at and near the sediment-water interface. In spite of their commonly large areal extent, direct measurements of flow in soft, organic sediments are rarely made and little is known about flux direction, rate, or heterogeneity. Commonly used monitoring wells are difficult to install and suffer from slow response to changing hydraulic head due to the low permeability of these sediments. Seepage meters can directly quantify seepage flux if several challenges can be overcome. Meters are difficult to install and operate where water is deep, visibility is poor, and the position of the sediment-water interface is not readily apparent. Soft, easily eroded sediment can be displaced during meter installation, creating bypass flow beneath the bottom of the seepage cylinder. Poorly competent sediments often cannot support the weight of the meters; they slowly sink into the bed and displace water inside the seepage cylinder, which leads to the interpretation of large upward flow. Decaying organic material within the sediment generates gas that can displace water and corrupt seepage-meter measurements. Several inexpensive modifications to a standard seepage meter, as well as precautions during installation and operation, can minimize these sources of error. Underwater video cameras can be mounted to the meter to remotely observe sediment disturbance during sensor installation and monitor the stability of the meter insertion depth during the period of deployment. Anchor rods can be driven a meter or more into the sediment until refusal, firmly anchoring the seepage meter at a constant sediment insertion depth. Data collected from modified seepage meters installed in Minnesota and New York demonstrate the importance of quantifying flows in these challenging settings where biogeochemistry is complex and seepage rates commonly have been assumed to be insignificantly small.
The value of registered nurses in ambulatory care settings: a survey.
Mastal, Margaret; Levine, June
2012-01-01
Ambulatory care settings employ 25% of the three million registered nurses in the United States. The American Academy of Ambulatory Care Nursing (AAACN) is committed to improving the quality of health care in ambulatory settings, enhancing patient outcomes, and realizing greater health care efficiencies. A survey of ambulatory care registered nurses indicates they are well positioned to lead and facilitate health care reform activities with organizational colleagues. They are well schooled in critical thinking, triage, advocating for patients, educating patients and families, collaborating with medical staff and other professionals, and care coordination. The evolving medical home concept and other health care delivery models reinforces the critical need for registered nurses to provide chronic disease management, care coordination, health risk appraisal, care transitions, health promotion, and disease prevention services. Recommendations are offered for organizational leaders, registered nurses, and AAACN to utilize nursing knowledge and skills in the pursuit of leading change and advancing health.
Image registration via optimization over disjoint image regions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitts, Todd; Hathaway, Simon; Karelitz, David B.
Technologies pertaining to registering a target image with a base image are described. In a general embodiment, the base image is selected from a set of images, and the target image is an image in the set of images that is to be registered to the base image. A set of disjoint regions of the target image is selected, and a transform to be applied to the target image is computed based on the optimization of a metric over the selected set of disjoint regions. The transform is applied to the target image so as to register the target imagemore » with the base image.« less
Schaap, Bryan D.
2004-01-01
The U.S. Environmental Protection Agency is working with the Yankton Sioux Tribe to develop a pesticide management plan to reduce potential for contamination of ground water that may result from the use of registered pesticides. The purpose of this study was to compile technical information to support development of a pesticide management plan by the Yankton Sioux Tribe for the area within the Yankton Sioux Reservation, Charles Mix County, South Dakota. Five pesticides (alachlor, atrazine, cyanazine, metolachlor, and simazine) were selected by the U.S. Environmental Protection Agency for the management plan approach because they had been identified as probable or possible human carcinogens and they often had been associated with ground-water contamination in many areas and at high concentrations. This report provides a compilation of data to support development of a pesticide management plan. Available data sets are summarized in the text of this report, and actual data sets are provided in one Compact Disk?Read-Only Memory that is included with the report. The compact disk contains data sets pertinent to the development of a pesticide management plan. Pesticide use for the study area is described using information from state and national databases. Within South Dakota, pesticides commonly are applied to corn and soybean crops, which are the primary row crops grown in the study area. Water-quality analyses for pesticides are summarized for several surface-water sites. Pesticide concentrations in most samples were found to be below minimum reporting levels. Topographic data are presented in the form of 30-meter digital elevation model grids and delineation of drainage basins. Geohydrologic data are provided for the surficial deposits and the bedrock units. A high-resolution (30-by-30 meters) land-cover and land-use database is provided and summarized in a tabular format. More than 91 percent of the study area is used for row crops, pasture, or hay, and almost 6 percent of the study area is covered by water or wetlands. Average monthly and yearly precipitation data are summarized in a tabular format. Irrigation information associated with permitted and licensed diversion points is provided. A composite of aerial photographs of Charles Mix County is provided. This report also describes and summarizes the data sets and files, and how the data are relevant to development of a pesticide management plan.
NASA TLA workload analysis support. Volume 2: Metering and spacing studies validation data
NASA Technical Reports Server (NTRS)
Sundstrom, J. L.
1980-01-01
Four sets of graphic reports--one for each of the metering and spacing scenarios--are presented. The complete data file from which the reports were generated is also given. The data was used to validate the detail task of both the pilot and copilot for four metering and spacing scenarios. The output presents two measures of demand workload and a report showing task length and task interaction.
Utilization of Large Data Sets in Maternal Health in Finland: A Case for Global Health Research.
Lamminpää, Reeta; Gissler, Mika; Vehviläinen-Julkunen, Katri
In recent years, the use of large data sets, such as electronic health records, has increased. These large data sets are often referred to as "Big Data," which have various definitions. The purpose of this article was to summarize and review the utilization, strengths, and challenges of register data, which means a written record containing regular entries of items or details, and Big Data, especially in maternal nursing, using 4 examples of studies from the Finnish Medical Birth Register data and relate these to other international databases and data sets. Using large health register data is crucial when studying and understanding outcomes of maternity care. This type of data enables comparisons on a population level and can be utilized in research related to maternal health, with important issues and implications for future research and clinical practice. Although there are challenges connected with register data and Big Data, these large data sets offer the opportunity for timely insight into population-based information on relevant research topics in maternal health. Nurse researchers need to understand the possibilities and limitations of using existing register data in maternity research. Maternal child nurse researchers can be leaders of the movement to utilize Big Data to improve global maternal health.
Omidbakhsh, Navid; Ahmadpour, Faraz; Kenny, Nicole
2014-01-01
Background Meters based on adenosine triphosphate (ATP) bioluminescence measurements in relative light units (RLU) are often used to rapidly assess the level of cleanliness of environmental surfaces in healthcare and other settings. Can such ATP measurements be adversely affected by factors such as soil and cleaner-disinfectant chemistry? Objective This study tested a number of leading ATP meters for their sensitivity, linearity of the measurements, correlation of the readings to the actual microbial contamination, and the potential disinfectant chemicals’ interference in their readings. Methods First, solutions of pure ATP in various concentrations were used to construct a standard curve and determine linearity and sensitivity. Serial dilutions of a broth culture of Staphylococcus aureus, as a representative nosocomial pathogen, were then used to determine if a given meter’s ATP readings correlated with the actual CFUs. Next, various types of disinfectant chemistries were tested for their potential to interfere with the standard ATP readings. Results All four ATP meters tested herein demonstrated acceptable linearity and repeatability in their readings. However, there were significant differences in their sensitivity to detect the levels of viable microorganisms on experimentally contaminated surfaces. Further, most disinfectant chemistries tested here quenched the ATP readings variably in different ATP meters evaluated. Conclusions Apart from their limited sensitivity in detecting low levels of microbial contamination, the ATP meters tested were also prone to interference by different disinfectant chemistries. PMID:24940751
16 CFR 303.20 - Registered identification numbers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Registered identification numbers. 303.20... identification numbers. (a) Registered numbers for use as the required identification in lieu of the name on... the form set out in paragraph (d) of this section. (b)(1) Registered identification numbers shall be...
LSST system analysis and integration task for an advanced science and application space platform
NASA Technical Reports Server (NTRS)
1980-01-01
To support the development of an advanced science and application space platform (ASASP) requirements of a representative set of payloads requiring large separation distances selected from the Science and Applications Space Platform data base. These payloads were a 100 meter diameter atmospheric gravity wave antenna, a 100 meter by 100 meter particle beam injection experiment, a 2 meter diameter, 18 meter long astrometric telescope, and a 15 meter diameter, 35 meter long large ambient deployable IR telescope. A low earth orbit at 500 km altitude and 56 deg inclination was selected as being the best compromise for meeting payload requirements. Platform subsystems were defined which would support the payload requirements and a physical platform concept was developed. Structural system requirements which included utilities accommodation, interface requirements, and platform strength and stiffness requirements were developed. An attitude control system concept was also described. The resultant ASASP concept was analyzed and technological developments deemed necessary in the area of large space systems were recommended.
Ambiguity effects of rhyme and meter.
Wallot, Sebastian; Menninghaus, Winfried
2018-04-23
Previous research has shown that rhyme and meter-although enhancing prosodic processing ease and memorability-also tend to make semantic processing more demanding. Using a set of rhymed and metered proverbs, as well as nonrhymed and nonmetered versions of these proverbs, the present study reveals this hitherto unspecified difficulty of comprehension to be specifically driven by perceived ambiguity. Roman Jakobson was the 1st to propose this hypothesis, in 1960. He suggested that "ambiguity is an intrinsic, inalienable feature" of "parallelistic" diction of which the combination of rhyme and meter is a pronounced example. Our results show that ambiguity indeed explains a substantial portion of the rhyme- and meter-driven difficulty of comprehension. Longer word-reading times differentially reflected ratings for ambiguity and comprehension difficulty. However, the ambiguity effect is not "inalienable." Rather, many rhymed and metered sentences turned out to be low in ambiguity. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
In-memory interconnect protocol configuration registers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Kevin Y.; Roberts, David A.
Systems, apparatuses, and methods for moving the interconnect protocol configuration registers into the main memory space of a node. The region of memory used for storing the interconnect protocol configuration registers may also be made cacheable to reduce the latency of accesses to the interconnect protocol configuration registers. Interconnect protocol configuration registers which are used during a startup routine may be prefetched into the host's cache to make the startup routine more efficient. The interconnect protocol configuration registers for various interconnect protocols may include one or more of device capability tables, memory-side statistics (e.g., to support two-level memory data mappingmore » decisions), advanced memory and interconnect features such as repair resources and routing tables, prefetching hints, error correcting code (ECC) bits, lists of device capabilities, set and store base address, capability, device ID, status, configuration, capabilities, and other settings.« less
Apparatus and method for implementing power saving techniques when processing floating point values
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young Moon; Park, Sang Phill
An apparatus and method are described for reducing power when reading and writing graphics data. For example, one embodiment of an apparatus comprises: a graphics processor unit (GPU) to process graphics data including floating point data; a set of registers, at least one of the registers of the set partitioned to store the floating point data; and encode/decode logic to reduce a number of binary 1 values being read from the at least one register by causing a specified set of bit positions within the floating point data to be read out as 0s rather than 1s.
Gschwind, Michael K [Chappaqua, NY
2011-03-01
Mechanisms for implementing a floating point only single instruction multiple data instruction set architecture are provided. A processor is provided that comprises an issue unit, an execution unit coupled to the issue unit, and a vector register file coupled to the execution unit. The execution unit has logic that implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA). The floating point vector registers of the vector register file store both scalar and floating point values as vectors having a plurality of vector elements. The processor may be part of a data processing system.
Using a PC as a Frequency Meter or a Counter.
ERIC Educational Resources Information Center
Sartori, J.; And Others
1995-01-01
Describes hardware that enables the use of an IBM PC microcomputer as a frequency meter or a counter by using the parallel printer port. Eliminates the 16-bit time-day counter through the use of an external time base that can be conveniently set depending on the desired frequency range. (JRH)
Colorado Wind Resource at 50 Meters Above Ground Level
Meters Above Ground Level Geospatial_Data_Presentation_Form: vector digital data Description: Abstract . Supplemental_Information: This data set has been validated by NREL and wind energy meteorological consultants. However, the data is not suitable for micro-siting potential development projects. This shapefile was generated from
NASA Astrophysics Data System (ADS)
Sudarmono, Panggih; Deendarlianto; Widyaparaga, Adhika
2018-05-01
Public street lighting consumes large energy for the public interest, but many street lights still do not use energy-saving technologies. In 2014, Provincial Government of DKI Jakarta operated 179,305 units of street lights. Of the number of installed armature, 92 % of them or 166,441 units are HPS (High-Pressure Sodium) armatures which are inefficient. In 2016, the Provincial Government of DKI Jakarta cut down the energy used for street lighting, by implementing the programs of kWh-meter installation in every street lighting panel and use energy-saving lamps equipped with the smart system. The Provincial Government of DKI Jakarta is registered with 6,399 customer IDs in PLN (State Owned Electric Company), and gradually carried out the kWh Meter installation and changes to the contract. The program to use energy-saving lights done by replacing the HPS armature that is not energy efficient to LED armature which is known to be energy efficient. Until the end of 2016, the number of armatures that has been replaced was 89,417 units. The research results on 25 samples of PLN customer IDs and the replacement of 2,162 units armature, showed that the energy efficiency through kWh meter installation and armature replacement reduce the power consumption from 330,414 kWh to 71,278 kWh or by 78.43%. Generally, there was a decrease in the value of electricity bill compared to the before the replacement. The program of kWh-meter installations and replacement of the armature has a payback period of 2.66 years.
Rest break organization in geriatric care and turnover: a multimethod cross-sectional study.
Wendsche, Johannes; Hacker, Winfried; Wegge, Jürgen; Schrod, Nadine; Roitzsch, Katharina; Tomaschek, Anne; Kliegel, Matthias
2014-09-01
Various determinants of nurses' work motivation and turnover behavior have been examined in previous studies. In this research, we extend this work by investigating the impact of care setting (nursing homes vs. home care services) and the important role of rest break organization. We aimed to identify direct and indirect linkages between geriatric care setting, rest break organization, and registered nurses' turnover assessed over a period of one year. We designed a multimethod cross-sectional study. 80 nursing units (n=45 nursing homes, n=35 home care) in 51 German geriatric care services employing 597 registered nurses. We gathered documentary, interview, and observational data about the organization of rest breaks, registered nurses' turnover, and additional organizational characteristics (type of ownership, location, nursing staff, clients, and client-to-staff-ratio). The findings show that the rest break system in geriatric nursing home units is more regularly as well as collectively organized and causes less unauthorized rest breaks than in home care units. Moreover, the feasibility of collective rest breaks was, as predicted, negatively associated with registered nurses' turnover and affected indirectly the relation between care setting and registered nurses' turnover. Care setting, however, had no direct impact on turnover. Furthermore, registered nurses' turnover was higher in for-profit care units than in public or non-profit units. This study reveals significant differences in rest break organization as a function of geriatric care setting and highlights the role of collective rest breaks for nursing staff retention. Our study underlines the integration of organizational context variables and features of rest break organization for the analysis of nursing turnover. Copyright © 2014 Elsevier Ltd. All rights reserved.
AGE Bio Diesel Emissions Evaluation
2003-12-01
329 44 788 Vratd) Standard Meter Volume, m° 1.336 1.214 1.255 1,268 am Average Sampling Rate, dscfm 0786 0 714 0 739 0 746 P, Stack Pressure, inches...sat) Moisture (at saturation), % by volume 70864 248 8 36676 V.d Standard Water Vapor Volume, ft’ 2.198 1 624 1 911 1-B• Dry Mole Fraction 0 941 0946...Clock Meter Dry Gas Sample Time, Volume, Rotameter Meter Temp., Vacuum, Probe Time (min) (24-hr) (liter) Setting (OF) (in.Hg) jTpr, OF /o5 f / 52 / 6 14V_
Calibration of the Minolta SPAD-502 leaf chlorophyll meter.
Markwell, J; Osterman, J C; Mitchell, J L
1995-01-01
Use of leaf meters to provide an instantaneous assessment of leaf chlorophyll has become common, but calibration of meter output into direct units of leaf chlorophyll concentration has been difficult and an understanding of the relationship between these two parameters has remained elusive. We examined the correlation of soybean (Glycine max) and maize (Zea mays L.) leaf chlorophyll concentration, as measured by organic extraction and spectrophotometric analysis, with output (M) of the Minolta SPAD-502 leaf chlorophyll meter. The relationship is non-linear and can be described by the equation chlorophyll (μmol m(-2))=10((M0.265)), r (2)=0.94. Use of such an exponential equation is theoretically justified and forces a more appropriate fit to a limited data set than polynomial equations. The exact relationship will vary from meter to meter, but will be similar and can be readily determined by empirical methods. The ability to rapidly determine leaf chlorophyll concentrations by use of the calibration method reported herein should be useful in studies on photosynthesis and crop physiology.
Registered nurses' clinical reasoning skills and reasoning process: A think-aloud study.
Lee, JuHee; Lee, Young Joo; Bae, JuYeon; Seo, Minjeong
2016-11-01
As complex chronic diseases are increasing, nurses' prompt and accurate clinical reasoning skills are essential. However, little is known about the reasoning skills of registered nurses. This study aimed to determine how registered nurses use their clinical reasoning skills and to identify how the reasoning process proceeds in the complex clinical situation of hospital setting. A qualitative exploratory design was used with a think-aloud method. A total of 13 registered nurses (mean years of experience=11.4) participated in the study, solving an ill-structured clinical problem based on complex chronic patients cases in a hospital setting. Data were analyzed using deductive content analysis. Findings showed that the registered nurses used a variety of clinical reasoning skills. The most commonly used skill was 'checking accuracy and reliability.' The reasoning process of registered nurses covered assessment, analysis, diagnosis, planning/implementation, and evaluation phase. It is critical that registered nurses apply appropriate clinical reasoning skills in complex clinical practice. The main focus of registered nurses' reasoning in this study was assessing a patient's health problem, and their reasoning process was cyclic, rather than linear. There is a need for educational strategy development to enhance registered nurses' competency in determining appropriate interventions in a timely and accurate fashion. Copyright © 2016 Elsevier Ltd. All rights reserved.
Metering Plan: Intelligent Operational Strategies Through Enhanced Metering Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pope, Jason E.
The Sustainability Program at Pacific Northwest National Laboratory (PNNL) has adopted a “triple-bottom-line” approach of environmental stewardship, social responsibility, and economic prosperity to its operations. Metering at PNNL works in support of all three, specifically to measure and inform building energy use and greenhouse gas emissions and minimize water use. The foundation for metering at PNNL is a core goal set, which consists of four objectives: providing accurate data without interruption, analyzing data while it is still new, providing actionable recommendations to operations management, and ensuring PNNL’s compliance with contract metering requirements. These core objectives guide the decisions that wemore » make during annual planning and as we operate throughout the year. This 2016 edition of the Metering Plan conveys the metering practices for and vision of the Sustainability Program. Changes in this plan from the 2015 edition include updated tables and an enhanced discussion on energy tracking systems used at PNNL. This plan also discusses updated benchmarking strategies using PNNL’s graphics and analytics tool, BuildingOS by Lucid Design Group. This plan presents our progress toward the metering goals shared by all federal agencies and highlights our successful completion of metering requirements. Currently, PNNL is fully compliant with the applicable legislative and Executive Order metering requirements. PNNL’s approach to the installation of new meters will be discussed. Perhaps most importantly, this plan details the analysis techniques utilized at PNNL that rely on the endless streams of data newly available as a result of increased meter deployment over the last several years. Previous Metering Plans have documented specific meter connection schemes as PNNL focused on deploying meters in a first step toward managing energy and water use. This plan serves not only to highlight PNNL’s successful completion of agency metering goals, but also can be used as a guideline for meter installation and data analysis.« less
Core outcome sets in women's and newborn health: a systematic review.
Duffy, Jmn; Rolph, R; Gale, C; Hirsch, M; Khan, K S; Ziebland, S; McManus, R J
2017-09-01
Variation in outcome collection and reporting is a serious hindrance to progress in our specialty; therefore, over 80 journals have come together to support the development, dissemination, and implementation of core outcome sets. This study systematically reviewed and characterised registered, progressing, or completed core outcome sets relevant to women's and newborn health. Systematic search using the Core Outcome Measures in Effectiveness Trial initiative and the Core Outcomes in Women's and Newborn Health initiative databases. Registry entries, protocols, systematic reviews, and core outcome sets. Descriptive statistics to describe characteristics and results. There were 49 core outcome sets registered in maternal and newborn health, with the majority registered in 2015 (n = 22; 48%) or 2016 (n = 16; 32%). Benign gynaecology (n = 8; 16%) and newborn health (n = 3; 6%) are currently under-represented. Twenty-four (52%) core outcome sets were funded by international (n = 1; <1%), national (n = 18; 38%), and regional (n = 4; 8%) bodies. Seven protocols were published. Twenty systematic reviews have characterised the inconsistency in outcome reporting across a broad range of relevant healthcare conditions. Four core outcome sets were completed: reconstructive breast surgery (11 outcomes), preterm birth (13 outcomes), epilepsy in pregnancy (29 outcomes), and maternity care (48 outcomes). The quantitative, qualitative, and consensus methods used to develop core outcome sets varied considerably. Core outcome sets are currently being developed across women's and newborn health, although coverage of topics is variable. Development of further infrastructure to develop, disseminate, and implement core outcome sets is urgently required. Forty-nine women's and newborn core outcome sets registered. 50% funded. 7 protocols, 20 systematic reviews, and 4 core outcome sets published. @coreoutcomes @jamesmnduffy. © 2017 Royal College of Obstetricians and Gynaecologists.
The 4M comPany: Make Mine Metric Marvels. Third Grade Teacher's Guide.
ERIC Educational Resources Information Center
Hawaii State Dept. of Education, Honolulu.
This is one of several teacher's guides for the 4M Company, a set of materials for teaching metric concepts and computation skills to elementary school students. Included in this guide are sections on needed materials, length (ancient Hawaiian units, meter decimeter, centimeter, addition, subtraction), decimals related to meters (measurement,…
Moisture Determination of Nuts and Dry Fruits using a Capacitance Sensor
USDA-ARS?s Scientific Manuscript database
Impedance (Z), and phase angle (') of a cylindrical parallel-plate capacitor with in-shell peanuts between the plates was measured earlier, using a CI meter (Chari’s Impedance meter), at 1 and 5 MHz . Capacitance C, was derived from Z and ', and using the C, ', and Z values of a set of peanuts whos...
Sensing the Moisture Content of Dry Cherries - A Rapid and Nondestructive Method
USDA-ARS?s Scientific Manuscript database
Impedance (Z), and phase angle (') of a parallel-plate capacitor with a single cherry fruit between the plates was measured using a CI meter (Chari’s Impedance meter), at 1 and 9 MHz . Capacitance C, was derived from Z and ', and using the C, ', and Z values of a set of cherries whose moisture cont...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-05
... naval ship: Annex I, paragraph 3(c), pertaining to the placement of task lights not less than two meters... safety, Navigation (water), and Vessels. 0 For the reasons set forth in the preamble, amend part 706 of... vessel in the athwartship direction * * * * * * * USS OSCAR AUSTIN DDG 79 1.89 meters...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strelnikov, N.; Vasserman, I.; Xu, J.
As part of the R&D program of the LCLS-II project, a novel 3.4-meter-long undulator prototype with horizontal magnetic field and dynamic force compensation has recently been developed at the Advanced Photon Source (APS). Some previous steps in this development were the shorter 0.8-meter-long and 2.8-meter-long prototypes. Extensive mechanical and magnetic testing was carried out for each prototype, and each prototype was magnetically tuned using magnetic shims. Furthermore, the resulting performance of the 3.4-meter-long undulator prototype meets all requirements for the LCLS-II insertion device, including limits on the field integrals, phase errors, higher-order magnetic moments, and electron-beam trajectory for all operationalmore » gaps, as well as the reproducibility and accuracy of the gap settings.« less
New scientific ocean drilling depth record extends study of subseafloor life
NASA Astrophysics Data System (ADS)
Showstack, Randy
2012-09-01
The Japanese deep-sea drilling vessel Chikyu set a new depth record for scientific ocean drilling and core retrieval by reaching a depth of 2119.5 meters below the seafloor (mbsf) on 6 September. This is 8.5 meters deeper than the prior record, set 19 years ago. Three days later, on 9 September, Chikyu set another record by reaching a drilling depth of 2466 mbsf, the maximum depth that will be attempted during the current expedition. The 6 September record was set on day 44 of the Deep Coalbed Biosphere off Shimokita expedition, which is expedition 337 of the Integrated Ocean Drilling Program (IODP). It occurred at drilling site C0020 in the northwestern Pacific Ocean, approximately 80 kilometers northeast from Hachinohe, Japan. The expedition is scheduled to conclude on 30 September.
Crveno jezero - the biggest sinkhole in Dinaric Karst (Croatia)
NASA Astrophysics Data System (ADS)
Garasic, M.
2012-04-01
Crveno jezero is a karst phenomenon known throughout the world for its size and specific features. In the course of the 1950's, some hydrological measurements were made on the surface of the lake, including depth measurement at 39 points (academician M. Petrik and his associates). The information about the maximum depth of 254 meters actually originates from that research (PETRIK, 1960). This depth has been "attracting" geologists, hydrogeologists and speleologists for many years now. On numerous occasions, people descended to the surface of the lake but, in the period prior to speleohydrogeological research conducted in 1998, no attempt had been made to dive underwater and document the lake depth, nor to investigate by other methods the interior of the lake and give a scientifically documented representation of this karst phenomenon from the speleohydrogeological aspect (GARAŠIĆ, 2000; 2001). The Red Lake, located one kilometer to the west of Imotski, is the biggest of all lakes situated in the area (featuring 18 big or small dry or water-filled depressions) and this by both its visible (superficial) and invisible (submerged) portions. Its name originates from red rocks perched on cliffs extending to more than 250 meters in height. The lake color is dark blue, and it measures about 150 x 180 meters, depending on water level, i.e. on the time of the year. The easiest way to reach the lake (belay, descend and ascend with ropes) is to approach it from the east side. Here we have a vertical cliff about 60 meters in height, followed by 300 meters of a very steep soil creep zone, after which there is yet another vertical cliff of at least ten meters in height (depending on lake water level). In other words, a special descending technique must be used to access any point along the lake perimeter in summer months. Vertical and overhanging cliffs rising above the surface of the lake range from 160 to 250 meters in height. However, the depth of the lake is even more fascinating and has been measured on a number of occasions. Valuable and interesting data about the lake depth, as presented by academician Milivoj Petrik in 1955, show that the lake is about 250 meters deep, which discouraged any attempts to dive to the bottom of the lake. During the 5th International Congress of Speleology held in Stuttgart in Germany, Croatian cavers and speleologists have tried to add the Red Lake to the list of deepest pits in the world, as its real depth amounted to 518 meters at the time. However, the response of the documentation committee was that the depth had not been duly documented, that no man has been at such depth etc., although in reality it is a real pit one half of which is filled with water. In late 1970's and early 1980's the speleodiving activities rapidly gathered momentum in all parts of the world and it is in this period that deepest dives were made at the source called Fontaine de Vaucluse. At that time, a special underwater vehicle, the so called "Speleonaut", attained (without crew) the depth of 315 meters. Similar vehicle called Hyball descended down to the depth of 165 meters in Hranicke propasti in Czech Republic. These speleological structures are therefore considered as sufficiently documented and, as such, they have been added to the list of the world's deepest water structures. In 1980's speleodiving has became an increasingly popular cave exploration method in Croatia. Thus, the decision was made to contact the world's best speleodivers and invite them to investigate the Red Lake. In 1981, during their stay in the USA, Dr. Mladen Garašić contacted Mr. Jochan Hassenmayer who was at that time the best speleodiver of the world. However, because of political climate that prevailed in that period, Mr. Hassenmayer finally decided not to come to our country. In an unfortunate turn of events, this diver was later affected with a permanent disability. In the course of 1989 and 1990, Dr. Garašić established contact with Mr. Sheck Exley (from Florida , USA) who is considered to be the best speleodiver of all times. At the time, it was agreed that he and his team would come to Croatia during the summer of 1991 and that they will, in the course of this visit, investigate the Red Lake. Unfortunately, due to the outbreak of war, this has been postponed and, in 1994, this outstanding diver had a fatal accident while diving at the depth of about 300 meters. This accident has remained unexplained to this date. In the course of 1996, French speleodivers recommended German speleodivers that would be interested in the underwater exploration of deep speleological structures. In this respect, the contact was established in early 1997 with the German Caving Group from Hanover the members of which had by that time been diving at about 200 m below the water surface (ASPACHER, B.& all, 2000). This team visited the Red Lake on several occasions in 1997 and 1998 and, during these visits, the lake depth was measured (using an echo sounder and highly-accurate depth measuring devices) at the total of 454 points, while previous measurements conducted in 1955 were performed at 39 points only. The maximum depth registered during our measurements was 276.35 meters, which exceeds the depth determined in previous measurements by approximately twenty meters. The main objective of the "Red Lake 98" expedition was to obtain new data about the speleogenesis of this structure, about its morphology, hydrogeology, tectonics and biospeleology, and to produce an appropriate documentation (video recordings, structural-tectonics and speleological maps). This was a Croatian speleodiving expedition with international participation and was sponsored by the UIS members from Germany, Austria and Switzerland (GARAŠIĆ, 1999). Sedimentologic studies were conducted in cooperation with colleagues from Tubingen-based Max Planc Institute and with those from the Technical Faculty in Munich, while biospeleological studies were performed together with colleagues from Salzburg. Highly accurate topographic instruments were borrowed from the University of Zürich. Results and Final Considerations The development of speleological, speleo-hydrogeological and speleodiving methods encouraged new investigations and, in that respect, new exploration was carried out in the Red Lake during the summer of 1998. The depth of the lake was measured at 454 points, topographic measurements of underwater parts of the lake were made, and several hundred meters of cave canals (dry and submerged), within the area delineated by the lake's vertical cliffs, were investigated. The maximum depth of the lake (-281 meters) was measured and recorded by means of a special autonomous underwater vehicle, the quantity of water flowing into the lake through a cave canal was established, and the quantity of water contained in the lake was determined (approx. 16 million of cubic meters). Recent studies provided information that is highly useful for better understanding of this karst phenomenon. The inverse karstification was dominant in the genesis, while gravity karstification had an accessory role only (GARAŠIĆ & KOVAĈEVIĆ, 2000). The bottom of the lake is inclined towards the west, and the lowest point lies 6 meters below sea level. At the time of these investigations, strong water currents in the direction of southwest were observed at the depths ranging from -206 to -281 meters. The total difference in height is 528 meters (from the highest point at lake periphery to the lowest point registered at the bottom of the lake). The bottom of the lake is deeper down but, due to technical difficulties, the camera was unable to penetrate any further. This extension is in fact a large cave canal spreading obliquely in the southwest direction. The International speleodiving expedition "Crveno jezero 98" resulted in numerous new findings some of which are listed below: - a fully documented material (photographs, topographic maps, video recordings) about the previously unknown parts of the lake was established, -an inflow cave-shaped canal (measuring 30 x 30 meters) was discovered in the eastern part of the lake, at the depth of approximately 175 meters, - new assumptions were made about ground water circulation in this area, - it was concluded that principal karstification processes develop in the interior and spread towards the surface, i.e. that this is the zone dominated by an inverse karstification; a room measuring 400 x 300 x 500 meters has been created in the interior, which is quite amazing, - some new species of cave fish, crabs, frogs and insects were discovered and determined within the lake and in speleological structures, - all speleohydrogeological features, as well as most significant tectonic elements, were determined down to 90 m in depth, -sedimentological and petrological testing of the lake bottom was conducted (at four locations), - more than 800 meters of cave canals were discovered within the lake "crater", - more than 22 hours of video material was recorded, the deepest point registered by ROV (Remotely Operated Vehicle) is 236 meters, - the deepest point measured in the lake is 281 meters, i.e. 6 meters below sea level, - the constant water temperature is +7.9°C (50 m below the surface), - (westward) movement of ground water was registered at the bottom of the lake, - the total of 454 points were measured, - heliox was used to dive to the depth of 181 m, which is one of the deepest cave dives ever performed in the world (ASPACHER & BEHREND, 1999), - vertical difference between the highest and lowest points in the lake is - 528 meters, - the size of the lake bottom was established (about 300 x 300 m) while on its surface the lake measures approximately 180 x 200 meters, - as many as 43 members have participated in the expedition /22 from Croatia, 18 from Germany, 2 from Austria and 1 from Switzerland) - more than 20 tons of equipment and material were transported to the site., etc. The Red Lake is ONE OF THE DEEPEST KARST (CAVE) LAKES IN THE WORLD and its deepest measured level of -281 METERS is still not the deepest point of the lake! It is a water storage containing more than 16,000,000 cubic meters of water. More accurate figures will be obtained in the course of future explorations to be undertaken by a special kind of bathyscaph. The Red Lake is the world's largest documented and surveyed ground water storage in karst, and deserves to be appreciated as such.
Low Altitude AVIRIS Data for Mapping Landform Types on West Ship Island, Mississippi
NASA Technical Reports Server (NTRS)
Spruce, Joseph; Otvos, Ervin; Giardino, Marco
2002-01-01
A chain of barrier islands provides protection against hurricanes and severe storms along the south and southeastern shores of the United States. Barrier island landform types can be spectrally similar and as small as a few meters across, making highly detailed maps difficult to produce. To determine whether high-resolution airborne hyperspectral imagery could provide detailed maps of barrier island landform types, we used low-altitude hyperspectral and multispectral imagery to map surface environments of West Ship Island, Mississippi. We employed 3.4-meter AVIRIS hyperspectral imagery acquired in July 1999 and 0.5-meter ADAR multispectral data acquired in November 1997. The data were co-registered to digital ortho aerial imagery, and the AVIRIS data was scaled to ground reflectance using ATREM software. Unsupervised classification of AVIRIS and ADAR data proceeded using ISODATA clustering techniques. The resulting landform maps were field-checked and compared to aerial photography and digital elevation maps. Preliminary analyses indicated that the AVIRIS classification mapped more landform types, while the ADAR-based map enabled smaller patches to be identified. Used together, these maps provided a means to assess landform distributions of West Ship Island before and after Hurricane Gorges. Classification accuracy is being addressed through photo-interpretation and field surveys of sample areas selected with stratified random sampling.
Low Altitude AVIRIS Data for Mapping Landform Types on West Ship Island, Mississippi
NASA Technical Reports Server (NTRS)
Spruce, Joseph; Otvos, Ervin; Giardino, Marco
2003-01-01
A chain of barrier islands provides protection against hurricanes and severe storms along the southern and southeastern shores of the Unites States. Barrier island landform types can be spectrally similar and as small as a few meters across, making highly detailed maps difficult to produce. To determine whether high-resolution airborne hyperspectral imagery could provide detailed maps of barrier island landform types, we used low-altitude hyperspectral and multispectral imagery to map surface environments of West Ship Island, Mississippi. We employed 3.4 meter AVIRIS hyperspectral imagery acquired in July 1999 and 0.5 meter ADAR multispectral data acquired in November 1997. The data were co-registered to digital ortho aerial imagery, and the AVIRIS data was scaled to ground reflectance using ATREM software. Unsupervised classification of AVIRIS and ADAR data proceeded using ISODATA clustering techniques. The resulting landform maps were field-checked and compared to aerial photography and digital elevation maps. Preliminary analyses indicated that the AVIRIS classification mapped more landform types, while the ADAR-based map enabled smaller patches to be identified. Used together, these maps provided a means to assess landform distributions of West Ship Island before and after Hurricane Georges. Classification accuracy is being assessed through photo-interpretation and field surveys of sample areas selected with stratified random sampling.
Curl-meter of Electrical Fields In The Ground.
NASA Astrophysics Data System (ADS)
Krylov, S. M.; Maibuk, Z.-Ju. Ja.; Nikiforova, N. N.
A special instrument U curl-meter was designed and manufactured in the Institute of Physics of the Earth of RAS for measuring of variable electric fields during alternation of stressedly-deformed state in rock mass. The instrument consist the four-electrode unit and a circuit of analogue signal processing for separation of E U circulations or according to the StokesSs theorem, Curl E in absence of indirect sources. Four electrodes are laied out in rocks on angles of square and they are affixed by ring-type circuit to uninverting inputs of precision operational amplifiers. First input is connected to electrode N1, the second one is connected to N2 and so on. The independent inputs are grounded to a arbitrary point (the fifth electrode is SzeroT). The transmission factors of the circuit are set by resistors accurate to within 0.25 %. First and third, and also second and fourth outputs of the amplifiers are connected to the grad EX and grad EY calculation circuit (deduction circuits). So, if the vector components have different signs of both two EX values and two values EY, the gradient calculation circuit generates signal extremums. If in this case the signs inside pairs are identical , that means that the signal not- ring-type and it is absent on output (difference of the equal values with equal signs). The signals from outputs of the gradient calculations act into adding device for calculation of Curl E (circulation). Curl-meter differs by high security from clutters and from cues on any of inputs rather of "zero point" (ground) reacting only on a ring-type current, thus it is essential (on the order) the noise level and drift of operational amplifiers is moderated. Curl-meter works in a complex of measuring devices on Obninsk seismological polygon for study of behavior of superlow frequency of tectonic genesis electromagnetic emission. Through four inputs (electrode spacing 7x7 2, resistance between welding rods 0.8 - 1.1 kOm), manufactured from fine- dyspersated of a graphitic dust with connecting on the basis of paraffine confidently registers signals by 0.2 microvolts amplitude in a frequency range 0.05 - 20 Hz on a background of considerable clutters of an industrial genesis. Technique in operation in geophysical observations the three-electrode installations were not applied in these studies because of a low industrial noise immunity and low sensitivity (5 microvolts). 1 This work was carried out by finance support RFFR Grant N 01-05-64153 2
Using Registered Dental Hygienists to Promote a School-Based Approach to Dental Public Health
Wellever, Anthony; Kelly, Patricia
2017-01-01
We examine a strategy for improving oral health in the United States by focusing on low-income children in school-based settings. Vulnerable children often experience cultural, social, economic, structural, and geographic barriers when trying to access dental services in traditional dental office settings. These disparities have been discussed for more than a decade in multiple US Department of Health and Human Services publications. One solution is to revise dental practice acts to allow registered dental hygienists increased scope of services, expanded public health delivery opportunities, and decreased dentist supervision. We provide examples of how federally qualified health centers have implemented successful school-based dental models within the parameters of two state policies that allow registered dental hygienists varying levels of dentist supervision. Changes to dental practice acts at the state level allowing registered dental hygienists to practice with limited supervision in community settings, such as schools, may provide vulnerable populations greater access to screening and preventive services. We derive our recommendations from expert opinion. PMID:28661808
An area model for on-chip memories and its application
NASA Technical Reports Server (NTRS)
Mulder, Johannes M.; Quach, Nhon T.; Flynn, Michael J.
1991-01-01
An area model suitable for comparing data buffers of different organizations and arbitrary sizes is described. The area model considers the supplied bandwidth of a memory cell and includes such buffer overhead as control logic, driver logic, and tag storage. The model gave less than 10 percent error when verified against real caches and register files. It is shown that, comparing caches and register files in terms of area for the same storage capacity, caches generally occupy more area per bit than register files for small caches because the overhead dominates the cache area at these sizes. For larger caches, the smaller storage cells in the cache provide a smaller total cache area per bit than the register set. Studying cache performance (traffic ratio) as a function of area, it is shown that, for small caches, direct-mapped caches perform significantly better than four-way set-associative caches and, for caches of medium areas, both direct-mapped and set-associative caches perform better than fully associative caches.
Calibration of GPS based high accuracy speed meter for vehicles
NASA Astrophysics Data System (ADS)
Bai, Yin; Sun, Qiao; Du, Lei; Yu, Mei; Bai, Jie
2015-02-01
GPS based high accuracy speed meter for vehicles is a special type of GPS speed meter which uses Doppler Demodulation of GPS signals to calculate the speed of a moving target. It is increasingly used as reference equipment in the field of traffic speed measurement, but acknowledged standard calibration methods are still lacking. To solve this problem, this paper presents the set-ups of simulated calibration, field test signal replay calibration, and in-field test comparison with an optical sensor based non-contact speed meter. All the experiments were carried out on particular speed values in the range of (40-180) km/h with the same GPS speed meter. The speed measurement errors of simulated calibration fall in the range of +/-0.1 km/h or +/-0.1%, with uncertainties smaller than 0.02% (k=2). The errors of replay calibration fall in the range of +/-0.1% with uncertainties smaller than 0.10% (k=2). The calibration results justify the effectiveness of the two methods. The relative deviations of the GPS speed meter from the optical sensor based noncontact speed meter fall in the range of +/-0.3%, which validates the use of GPS speed meter as reference instruments. The results of this research can provide technical basis for the establishment of internationally standard calibration methods of GPS speed meters, and thus ensures the legal status of GPS speed meters as reference equipment in the field of traffic speed metrology.
USDA-ARS?s Scientific Manuscript database
Impedance (Z), and phase angle (') of a cylindrical parallel-plate capacitor with dry fruits between the plates was measured using a CI meter (Chari’s Impedance meter), at 1 and 9 MHz . Capacitance, C was derived from Z and ', and using the C, ', and Z values of a set of cherries whose moisture con...
Mayo, Lawrence R.; Trabant, Dennis C.; March, Rod S.
2004-01-01
Scientific measurements at Wolverine Glacier, on the Kenai Peninsula in south-central Alaska, began in April 1966. At three long-term sites in the research basin, the measurements included snow depth, snow density, heights of the glacier surface and stratigraphic summer surfaces on stakes, and identification of the surface materials. Calculations of the mass balance of the surface strata-snow, new firn, superimposed ice, and old firn and ice mass at each site were based on these measurements. Calculations of fixed-date annual mass balances for each hydrologic year (October 1 to September 30), as well as net balances and the dates of minimum net balance measured between time-transgressive summer surfaces on the glacier, were made on the basis of the strata balances augmented by air temperature and precipitation recorded in the basin. From 1966 through 1995, the average annual balance at site A (590 meters altitude) was -4.06 meters water equivalent; at site B (1,070 meters altitude), was -0.90 meters water equivalent; and at site C (1,290 meters altitude), was +1.45 meters water equivalent. Geodetic determination of displacements of the mass balance stake, and glacier surface altitudes was added to the data set in 1975 to detect the glacier motion responses to variable climate and mass balance conditions. The average surface speed from 1975 to 1996 was 50.0 meters per year at site A, 83.7 meters per year at site B, and 37.2 meters per year at site C. The average surface altitudes were 594 meters at site A, 1,069 meters at site B, and 1,293 meters at site C; the glacier surface altitudes rose and fell over a range of 19.4 meters at site A, 14.1 meters at site B, and 13.2 meters at site C.
NASA Astrophysics Data System (ADS)
Waseda, Takuji
2010-03-01
Giant episodic ocean waves that suddenly soar like a wall of water out of an otherwise calm sea are not just a legend. Such waves—which in the past have been called “abnormal,” “exceptional,” “extreme,” and even “vicious killer” waves—are now commonly known as “rogue waves” or “freak waves.” These waves have sunk or severely damaged 22 supercarriers in the world and caused the loss of more than 500 lives in the past 40 years. The largest wave registered by reliable instruments reached 30 meters in height, and the largest wave recorded by visual observation reached about 34 meters, equivalent to the height of an eight-story building. Tales of seafarers from Christopher Columbus to the passengers of luxury cruise ships had long been undervalued by scientists, but in the past 10 or so years, those historical notes and modern testimonies have been scientifically dissected to reveal the nature of these monster waves.
The Experiences of Registered Nurses Transitioning from Patient Care Settings to Academia
ERIC Educational Resources Information Center
Gwin, Teresa
2012-01-01
Registered nurses (RNs) who make the move from a patient-care service setting to an academic teaching environment often go through a transition phase in their first semesters of teaching that is difficult and traumatic. RNs that go on to higher academic degrees often do so in order to teach in schools of nursing. However, graduate work in nursing…
Meter-Scale 3-D Models of the Martian Surface from Combining MOC and MOLA Data
NASA Technical Reports Server (NTRS)
Soderblom, Laurence A.; Kirk, Randolph L.
2003-01-01
We have extended our previous efforts to derive through controlled photoclinometry, accurate, calibrated, high-resolution topographic models of the martian surface. The process involves combining MGS MOLA topographic profiles and MGS MOC Narrow Angle images. The earlier work utilized, along with a particular MOC NA image, the MOLA topographic profile that was acquired simultaneously, in order to derive photometric and scattering properties of the surface and atmosphere so as to force the low spatial frequencies of a one-dimensional MOC photoclinometric model to match the MOLA profile. Both that work and the new results reported here depend heavily on successful efforts to: 1) refine the radiometric calibration of MOC NA; 2) register the MOC to MOLA coordinate systems and refine the pointing; and 3) provide the ability to project into a common coordinate system, simultaneously acquired MOC and MOLA with a single set of SPICE kernels utilizing the USGS ISIS cartographic image processing tools. The approach described in this paper extends the MOC-MOLA integration and cross-calibration procedures from one-dimensional profiles to full two-dimensional photoclinometry and image simulations. Included are methods to account for low-frequency albedo variations within the scene.
Reflections on Distributive Leadership for Work-Based Mobile Learning of Canadian Registered Nurses
ERIC Educational Resources Information Center
Fahlman, Dorothy
2017-01-01
The ubiquity, flexibility, and accessibility of mobile devices can transform how registered nurses in Canada learn beyond the confines of traditional education/training boundaries in their work settings. Many Canadian registered nurses have actively embraced mobile technologies for their work-based learning to meet their competency requirements…
Weak-value amplification as an optimal metrological protocol
NASA Astrophysics Data System (ADS)
Alves, G. Bié; Escher, B. M.; de Matos Filho, R. L.; Zagury, N.; Davidovich, L.
2015-06-01
The implementation of weak-value amplification requires the pre- and postselection of states of a quantum system, followed by the observation of the response of the meter, which interacts weakly with the system. Data acquisition from the meter is conditioned to successful postselection events. Here we derive an optimal postselection procedure for estimating the coupling constant between system and meter and show that it leads both to weak-value amplification and to the saturation of the quantum Fisher information, under conditions fulfilled by all previously reported experiments on the amplification of weak signals. For most of the preselected states, full information on the coupling constant can be extracted from the meter data set alone, while for a small fraction of the space of preselected states, it must be obtained from the postselection statistics.
Vertically polarizing undulator with dynamic compensation of magnetic forces
Strelnikov, N.; Vasserman, I.; Xu, J.; ...
2017-01-20
As part of the R&D program of the LCLS-II project, a novel 3.4-meter-long undulator prototype with horizontal magnetic field and dynamic force compensation has recently been developed at the Advanced Photon Source (APS). Some previous steps in this development were the shorter 0.8-meter-long and 2.8-meter-long prototypes. Extensive mechanical and magnetic testing was carried out for each prototype, and each prototype was magnetically tuned using magnetic shims. Furthermore, the resulting performance of the 3.4-meter-long undulator prototype meets all requirements for the LCLS-II insertion device, including limits on the field integrals, phase errors, higher-order magnetic moments, and electron-beam trajectory for all operationalmore » gaps, as well as the reproducibility and accuracy of the gap settings.« less
Storm Surge Modeling of Typhoon Haiyan at the Naval Oceanographic Office Using Delft3D
NASA Astrophysics Data System (ADS)
Gilligan, M. J.; Lovering, J. L.
2016-02-01
The Naval Oceanographic Office provides estimates of the rise in sea level along the coast due to storm surge associated with tropical cyclones, typhoons, and hurricanes. Storm surge modeling and prediction helps the US Navy by providing a threat assessment tool to help protect Navy assets and provide support for humanitarian assistance/disaster relief efforts. Recent advancements in our modeling capabilities include the use of the Delft3D modeling suite as part of a Naval Research Laboratory (NRL) developed Coastal Surge Inundation Prediction System (CSIPS). Model simulations were performed on Typhoon Haiyan, which made landfall in the Philippines in November 2013. Comparisons of model simulations using forecast and hindcast track data highlight the importance of accurate storm track information for storm surge predictions. Model runs using the forecast track prediction and hindcast track information give maximum storm surge elevations of 4 meters and 6.1 meters, respectively. Model results for the hindcast simulation were compared with data published by the JSCE-PICE Joint survey for locations in San Pedro Bay (SPB) and on the Eastern Samar Peninsula (ESP). In SPB, where wind-induced set-up predominates, the model run using the forecast track predicted surge within 2 meters in 38% of survey locations and within 3 meters in 59% of the locations. When the hindcast track was used, the model predicted within 2 meters in 77% of the locations and within 3 meters in 95% of the locations. The model was unable to predict the high surge reported along the ESP produced by infragravity wave-induced set-up, which is not simulated in the model. Additional modeling capabilities incorporating infragravity waves are required to predict storm surge accurately along open coasts with steep bathymetric slopes, such as those seen in island arcs.
Conversion of board foot scaled logs to cubic meters in Washington State, 1970–1998
Henry Spelter
2002-01-01
The conversion factor generally used to convert logs measured in board feet to cubic meters has traditionally been set at 4.53. Because of diminishing old growth, large diameter trees, the average conversion factor has risen, as illustrated in this analysis of Washington state sawmill data over the period 1970â1998. Conversion factors for coastal and interior...
2006-04-01
Primary mirror of Zerodur with Pilkington 747 coating • FOV = 0.104 degrees Airborne Intercept Monitoring RTO-MP-SET-105 16 - 3 UNCLASSIFIED...Pointing System (SPS). The STS is a 0.75 meter aperture Mersenne Cassegrain telescope and the SAT is a 0.34 meter aperture 3- mirror anastigmat telescope...UNLIMITED UNCLASSIFIED/UNLIMITED • Air Flow to Mitigate Thermal “Seeing” Effects • Light weighted primary mirror to reduce mass The SAT
Continued development of a detailed model of arc discharge dynamics
NASA Technical Reports Server (NTRS)
Beers, B. L.; Pine, V. W.; Ives, S. T.
1982-01-01
Using a previously developed set of codes (SEMC, CASCAD, ACORN), a parametric study was performed to quantify the parameters which describe the development of a single electron indicated avalanche into a negative tip streamer. The electron distribution function in Teflon is presented for values of the electric field in the range of four-hundred million volts/meter to four billon volts/meter. A formulation of the scattering parameters is developed which shows that the transport can be represented by three independent variables. The distribution of ionization sites is used to indicate an avalanche. The self consistent evolution of the avalanche is computed over the parameter range of scattering set.
Integrated Fuel Injection and Mixing System with Impingement Cooling Face
NASA Technical Reports Server (NTRS)
Mansour, Adel B. (Inventor); Harvey, Rex J. (Inventor); Tacina, Robert R. (Inventor); Laing, Peter (Inventor)
2003-01-01
An atomizing injector includes a metering set having a swirl chamber, a spray orifice and one or more feed slots etched in a thin plate. The swirl chamber is etched in a first side of the plate and the spray orifice is etched through a second side to the center of the swirl chamber. Fuel feed slots extend non-radially to the swirl chamber. The injector also includes integral swirler structure. The swirler structure includes a cylindrical air swirler passage, also shaped by etching, through at least one other thin plate. The cylindrical air swirler passage is located in co-axial relation to the spray orifice of the plate of the fuel metering set such that fuel directed through the spray orifice passes through the air swirler passage and swirling air is imparted to the fuel such that the fuel has a swirling component of motion. At least one air feed slot is provided in fluid communication with the air swirler passage and extends in non-radial relation thereto. Air supply passages extend through the plates of the metering set and the swirler structure to feed the air feed slot in each plate of the swirler structure.
Hageman, David; Gommans, Lindy Nm; Scheltinga, Marc Rm; Teijink, Joep Aw
2017-02-01
Some believe that certain patients with intermittent claudication may be unsuitable for supervised exercise therapy (SET), based on the presence of comorbidities and the possibly increased risks. We conducted a systematic review (MEDLINE, EMBASE and CENTRAL) to summarize evidence on the potential influence of diabetes mellitus (DM) on the response to SET. Randomized and nonrandomized studies that investigated the effect of DM on walking distance after SET in patients with IC were included. Considered outcome measures were maximal, pain-free and functional walking distance (MWD, PFWD and FWD). Three articles met the inclusion criteria ( n = 845). In one study, MWD was 111 meters (128%) longer in the non-DM group compared to the DM group after 3 months of follow-up ( p = 0.056). In a second study, the non-DM group demonstrated a significant increase in PFWD (114 meters, p ⩽ 0.05) after 3 months of follow-up, whereas there was no statistically significant increase for the DM group (54 meters). On the contrary, the largest study of this review did not demonstrate any adverse effect of DM on MWD and FWD after SET. In conclusion, the data evaluating the effects of DM on SET were inadequate to determine if DM impairs the exercise response. While trends in the data do not suggest an impairment, they are not conclusive. Practitioners should consider this limitation when making clinical decisions.
Development and Testing of the Europa Mission's Venturi Flow Meter
NASA Technical Reports Server (NTRS)
Diaz, C. E.; McKim, S. A.
2017-01-01
NASA's Marshall Space Flight Center (MSFC), in collaboration with NASA's Goddard Space Flight Center (GSFC), Fox Valve Development Corp. and Oxford Lasers, is developing a set of venturi flow meters for use on the Europa Mission's propulsion subsystem. The requirement for the venturi flow meters' throat diameters is approximately 0.040". An early risk reduction activity conducted by MSFC revealed that a venturi flow meter produced by FOX with a throat diameter near 0.040" had much higher pressure loss than venturi flow meters with larger throat diameters and venturis of similar throat diameter size but with no pressure taps (i.e. venturis with a throat length to diameter ratio of zero). In response, a series of venturi flow meters was fabricated and flow tested to gain insight into pressure recovery as it is affected by pressure port diameter, throat length and diffuser angle in an effort to improve the performance of a venturi flow meter. This presentation provides a summary of the venturi flow meter development activity including: a description of the test's objectives, a detailed description of each venturi configuration, a description of the manufacturing processes of the venturis, and observations from the test data. A summary of the current development activities will also be given, as well as the current development path forward. Ultimately, the knowledge gained through the fabrication and testing of these venturis provides guidance to design a flight venturi flow meters with pressure recoveries that is acceptable for the Europa flight application.
Mungun, Tuya; Dorj, Narangerel; Volody, Baigal; Chuluundorj, Uranjargal; Munkhbat, Enkhtuya; Danzan, Gerelmaa; Nguyen, Cattram D; La Vincente, Sophie; Russell, Fiona
2017-01-01
Introduction Monitoring of vaccination coverage is vital for the prevention and control of vaccine-preventable diseases. Electronic immunization registers have been increasingly adopted to assist with the monitoring of vaccine coverage; however, there is limited literature about the use of electronic registers in low- and middle-income countries such as Mongolia. We aimed to determine the accuracy and completeness of the newly introduced electronic immunization register for calculating vaccination coverage and determining vaccine effectiveness within two districts in Mongolia in comparison to written health provider records. Methods We conducted a cross-sectional record review among children 2–23 months of age vaccinated at immunization clinics within the two districts. We linked data from written records with the electronic immunization register using the national identification number to determine the completeness and accuracy of the electronic register. Results Both completeness (90.9%; 95% CI: 88.4–93.4) and accuracy (93.3%; 95% CI: 84.1–97.4) of the electronic immunization register were high when compared to written records. The increase in completeness over time indicated a delay in data entry. Conclusion Through this audit, we have demonstrated concordance between a newly introduced electronic register and health provider records in a middle-income country setting. Based on this experience, we recommend that electronic registers be accompanied by routine quality assurance procedures for the monitoring of vaccination programmes in such settings. PMID:29051836
Use of an Electromagnetic Seepage Meter to Investigate Temporal Variability in Lake Seepage
Rosenberry, D.O.; Morin, R.H.
2004-01-01
A commercially available electromagnetic flowmeter is attached to a seepage cylinder to create an electromagnetic seepage meter (ESM) for automating measurement of fluxes across the sediment/water interface between ground water and surface water. The ESM is evaluated through its application at two lakes in New England, one where water seeps into the lake and one where water seeps out of the lake. The electromagnetic flowmeter replaces the seepage-meter bag and provides a continuous series of measurements from which temporal seepage processes can be investigated. It provides flow measurements over a range of three orders of magnitude, and contains no protruding components or moving parts. The ESM was used to evaluate duration of seepage disturbance following meter installation and indicated natural seepage rates resumed approximately one hour following meter insertion in a sandy lakebed. Lakebed seepage also varied considerably in response to lakebed disturbances, near-shore waves, and rain-falls, indicating hydrologic processes are occurring in shallow lakebed settings at time scales that have largely gone unobserved.
Use of an electromagnetic seepage meter to investigate temporal variability in lake seepage.
Rosenberry, Donald O; Morin, Roger H
2004-01-01
A commercially available electromagnetic flowmeter is attached to a seepage cylinder to create an electromagnetic seepage meter (ESM) for automating measurement of fluxes across the sediment/water interface between ground water and surface water. The ESM is evaluated through its application at two lakes in New England, one where water seeps into the lake and one where water seeps out of the lake. The electromagnetic flowmeter replaces the seepage-meter bag and provides a continuous series of measurements from which temporal seepage processes can be investigated. It provides flow measurements over a range of three orders of magnitude, and contains no protruding components or moving parts. The ESM was used to evaluate duration of seepage disturbance following meter installation and indicated natural seepage rates resumed approximately one hour following meter insertion in a sandy lakebed. Lakebed seepage also varied considerably in response to lakebed disturbances, near-shore waves, and rainfalls, indicating hydrologic processes are occurring in shallow lakebed settings at time scales that have largely gone unobserved.
Robust, non-invasive methods for metering groundwater well extraction in remote environments
NASA Astrophysics Data System (ADS)
Bulovic, Nevenka; Keir, Greg; McIntyre, Neil
2017-04-01
Quantifying the rate of extraction from groundwater wells can be essential for regional scale groundwater management and impact assessment. This is especially the case in regions heavily dependent on groundwater such as the semi-arid Surat and Bowen Basins in Queensland, Australia. Of the 30 000+ groundwater wells in this area, the majority of which are used for stock watering and domestic purposes, almost none have flow metering devices installed. As part of a research project to estimate regional groundwater extraction, we have undertaken a small scale flow metering program on a selected set of wells. Conventional in-line flow meters were unsuitable for our project, as both non-invasiveness and adaptability / suitability to a variety of discharge pipe characteristics was critical. We describe the use of two metering technologies not widely used in groundwater applications, non-invasive, clamp-on ultrasonic transit time flow meters and tipping bucket flow meters, as semi-permanent installations on discharge pipes of various artesian and sub-artesian groundwater wells. We present examples of detailed extraction rate time-series, which are of particular value in developing predictive models of water well extraction in data limited areas where water use dynamics and drivers are poorly understood. We conclude by discussing future project trajectories, which include expansion of the monitoring network through development of novel metering techniques and telemetry across large areas of poor connectivity.
A Power Planning Algorithm Based on RPL for AMI Wireless Sensor Networks.
Miguel, Marcio L F; Jamhour, Edgard; Pellenz, Marcelo E; Penna, Manoel C
2017-03-25
The advanced metering infrastructure (AMI) is an architecture for two-way communication between electric, gas and water meters and city utilities. The AMI network is a wireless sensor network that provides communication for metering devices in the neighborhood area of the smart grid. Recently, the applicability of a routing protocol for low-power and lossy networks (RPL) has been considered in AMI networks. Some studies in the literature have pointed out problems with RPL, including sub-optimal path selection and instability. In this paper, we defend the viewpoint that careful planning of the transmission power in wireless RPL networks can significantly reduce the pointed problems. This paper presents a method for planning the transmission power in order to assure that, after convergence, the size of the parent set of the RPL nodes is as close as possible to a predefined size. Another important feature is that all nodes in the parent set offer connectivity through links of similar quality.
A Power Planning Algorithm Based on RPL for AMI Wireless Sensor Networks
Miguel, Marcio L. F.; Jamhour, Edgard; Pellenz, Marcelo E.; Penna, Manoel C.
2017-01-01
The advanced metering infrastructure (AMI) is an architecture for two-way communication between electric, gas and water meters and city utilities. The AMI network is a wireless sensor network that provides communication for metering devices in the neighborhood area of the smart grid. Recently, the applicability of a routing protocol for low-power and lossy networks (RPL) has been considered in AMI networks. Some studies in the literature have pointed out problems with RPL, including sub-optimal path selection and instability. In this paper, we defend the viewpoint that careful planning of the transmission power in wireless RPL networks can significantly reduce the pointed problems. This paper presents a method for planning the transmission power in order to assure that, after convergence, the size of the parent set of the RPL nodes is as close as possible to a predefined size. Another important feature is that all nodes in the parent set offer connectivity through links of similar quality. PMID:28346339
Physical and Radiative Characteristic and Long-term Variability of the Okhotsk Sea Ice Cover
NASA Technical Reports Server (NTRS)
Nishio, Fumihiko; Comiso, Josefino C.; Gersten, Robert; Nakayama, Masashige; Ukita, Jinro; Gasiewski, Al; Stanko, Boba; Naoki, Kazuhiro
2008-01-01
Much of what we know about the large scale characteristics of the Okhotsk Sea ice cover has been provided by ice concentration maps derived from passive microwave data. To understand what satellite data represent in a highly divergent and rapidly changing environment like the Okhotsk Sea, we take advantage of concurrent satellite, aircraft, and ship data acquired on 7 February and characterized the sea ice cover at different scales from meters to hundreds of kilometers. Through comparative analysis of surface features using co-registered data from visible, infrared and microwave channels we evaluated the general radiative and physical characteristics of the ice cover as well as quantify the distribution of different ice types in the region. Ice concentration maps from AMSR-E using the standard sets of channels, and also only the 89 GHz channel for optimal resolution, are compared with aircraft and high resolution visible data and while the standard set provides consistent results, the 89 GHz provides the means to observe mesoscale patterns and some unique features of the ice cover. Analysis of MODIS data reveals that thick ice types represents about 37% of the ice cover indicating that young and new ice types represent a large fraction of the ice cover that averages about 90% ice concentration according to passive microwave data. These results are used to interpret historical data that indicate that the Okhotsk Sea ice extent and area are declining at a rapid rate of about -9% and -12 % per decade, respectively.
Simple, inexpensive computerized rodent activity meters.
Horton, R M; Karachunski, P I; Kellermann, S A; Conti-Fine, B M
1995-10-01
We describe two approaches for using obsolescent computers, either an IBM PC XT or an Apple Macintosh Plus, to accurately quantify spontaneous rodent activity, as revealed by continuous monitoring of the spontaneous usage of running activity wheels. Because such computers can commonly be obtained at little or no expense, and other commonly available materials and inexpensive parts can be used, these meters can be built quite economically. Construction of these meters requires no specialized electronics expertise, and their software requirements are simple. The computer interfaces are potentially of general interest, as they could also be used for monitoring a variety of events in a research setting.
Blood Glucose Meters That Are Accessible to Blind and Visually Impaired Persons
Uslan, Mark M.; Burton, Darren M.; Clements, Charles W.
2008-01-01
Blood glucose meters (BGMs) that can be used nonvisually or with a visual limitation were introduced in the mid-1990s, but it was not until 2006 and 2007 that a new set of meters with accessibility features were introduced: Prodigy, Prodigy Autocode, and Prodigy Voice (Diagnostic Devices, Charlotte, NC), and Advocate and Advocate Redi-Code (TaiDoc, Taiwan). Accessibility attributes of the newly introduced BGMs were tabulated, and product design features were examined and documented. The Prodigy Voice was found to be the only one of these new BGMs that is fully usable by blind and visually impaired persons. PMID:19885356
Blood glucose meters that are accessible to blind and visually impaired persons.
Uslan, Mark M; Burton, Darren M; Clements, Charles W
2008-03-01
Blood glucose meters (BGMs) that can be used nonvisually or with a visual limitation were introduced in the mid-1990s, but it was not until 2006 and 2007 that a new set of meters with accessibility features were introduced: Prodigy, Prodigy Autocode, and Prodigy Voice (Diagnostic Devices, Charlotte, NC), and Advocate and Advocate Redi-Code (TaiDoc, Taiwan). Accessibility attributes of the newly introduced BGMs were tabulated, and product design features were examined and documented. The Prodigy Voice was found to be the only one of these new BGMs that is fully usable by blind and visually impaired persons.
The METER: A Brief, Self-Administered Measure of Health Literacy
Gunstad, John; Hughes, Joel; Spitznagel, Mary Beth; Potter, Vanessa; Waechter, Donna; Rosneck, James
2009-01-01
Background Given rapidly accumulating evidence that health literacy is correlated with important health-related measures, assessing patients’ health literacy level is of increasing concern for researchers and practitioners. Practical limitations for use of existing health literacy measures include length of time and practitioner involvement in administration. Objective To develop and validate a brief, self-administered measure of health literacy, the Medical Term Recognition Test (METER). Participants 155 participants were recruited from an outpatient cardiology program at an urban hospital. Measures Patients completed measures of health literacy (METER and REALM), neuropsychological function, psychosocial health, and self-report questionnaires about health behaviors. Indicators of cardiovascular health were also recorded from patients’ medical charts. Key results The measure took 2 min to complete. The internal consistency of the METER was 0.93, and it correlated highly with REALM (r = 0.74). Regarding sensitivity and specificity for identifying individuals below REALM’s cutoff for functional literacy, METER resulted in 75% correct identifications and 8% false positives. METER and REALM were both associated with various health-related measures (including significant correlations with measures of neuropsychological function and cardiovascular health). Conclusions These initial findings show that the METER is a quick and practical measure of health literacy for use in clinical settings. PMID:19885705
Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148
Lin, Shu-Ping; Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.
Validation of the ASTER instrument level 1A scene geometry
Kieffer, H.H.; Mullins, K.F.; MacKinnon, D.J.
2008-01-01
An independent assessment of the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument geometry was undertaken by the U.S. ASTER Team, to confirm the geometric correction parameters developed and applied to Level 1A (radiometrically and geometrically raw with correction parameters appended) ASTER data. The goal was to evaluate the geometric quality of the ASTER system and the stability of the Terra spacecraft. ASTER is a 15-band system containing optical instruments with resolutions from 15- to 90-meters; all geometrically registered products are ultimately tied to the 15-meter Visible and Near Infrared (VNIR) sub-system. Our evaluation process first involved establishing a large database of Ground Control Points (GCP) in the mid-western United States; an area with features of an appropriate size for spacecraft instrument resolutions. We used standard U.S. Geological Survey (USGS) Digital Orthophoto Quads (DOQS) of areas in the mid-west to locate accurate GCPs by systematically identifying road intersections and recording their coordinates. Elevations for these points were derived from USGS Digital Elevation Models (DEMS). Road intersections in a swath of nine contiguous ASTER scenes were then matched to the GCPs, including terrain correction. We found no significant distortion in the images; after a simple image offset to absolute position, the RMS residual of about 200 points per scene was less than one-half a VNIR pixel. Absolute locations were within 80 meters, with a slow drift of about 10 meters over the entire 530-kilometer swath. Using strictly simultaneous observations of scenes 370 kilometers apart, we determined a stereo angle correction of 0.00134 degree with an accuracy of one microradian. The mid-west GCP field and the techniques used here should be widely applicable in assessing other spacecraft instruments having resolutions from 5 to 50-meters. ?? 2008 American Society for Photogrammetry and Remote Sensing.
A Randomized Response Model For Privacy Preserving Smart Metering.
Wang, Shuang; Cui, Lijuan; Que, Jialan; Choi, Dae-Hyun; Jiang, Xiaoqian; Cheng, Samuel; Xie, Le
2012-09-01
The adoption of smart meters may bring new privacy concerns to the general public. Given the fact that metering data of individual homes/factories is accumulated every 15 minutes, it is possible to infer the pattern of electricity consumption of individual users. In order to protect the privacy of users in a completely de-centralized setting (i.e., individuals do not communicate with one another), we propose a novel protocol, which allows individual meters to report the true electricity consumption reading with a pre-determinted probability. Load serving entities (LSE) can reconstruct the total electricity consumption of a region or a district through inference algorithm, but their ability of identifying individual users' energy consumption pattern is significantly reduced. Using simulated data, we verify the feasibility of the proposed method and demonstrate performance advantages over existing approaches.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5... 46 Shipping 4 2010-10-01 2010-10-01 false Power sources on vessels of more than 19.8 meters (65...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...
ASTER-Derived 30-Meter-Resolution Digital Elevation Models of Afghanistan
Chirico, Peter G.; Warner, Michael B.
2007-01-01
INTRODUCTION The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) is an imaging instrument aboard the Terra satellite, launched on December 19, 1999, as part of the National Aeronautics and Space Administration's (NASA) Earth Observing System (EOS). The ASTER sensor consists of three subsystems: the visible and near infrared (VNIR), the shortwave infrared (SWIR), and the thermal infrared (TIR), each with a different spatial resolution (VNIR, 15 meters; SWIR, 30 meters, TIR 90 meters). The VNIR system has the capability to generate along-track stereo images that can be used to create digital elevation models (DEMs) at 30-meter resolution. Currently, the only available DEM dataset for Afghanistan is the 90-meter-resolution Shuttle Radar Topography Mission (SRTM) data. This dataset is appropriate for macroscale DEM analysis and mapping. However, ASTER provides a low cost opportunity to generate higher resolution data. For this publication, study areas were identified around populated areas and areas where higher resolution elevation data were desired to assist in natural resource assessments. The higher resolution fidelity of these DEMs can also be used for other terrain analysis including landform classification and geologic structure analysis. For this publication, ASTER scenes were processed and mosaicked to generate 36 DEMs which were created and extracted using PCI Geomatics' OrthoEngine 3D Stereo software. The ASTER images were geographically registered to Landsat data with at least 15 accurate and well distributed ground control points with a root mean square error (RMSE) of less that one pixel (15 meters). An elevation value was then assigned to each ground control point by extracting the elevation from the 90-meter SRTM data. The 36 derived DEMs demonstrate that the software correlated on nearly flat surfaces and smooth slopes accurately. Larger errors occur in cloudy and snow-covered areas, lakes, areas with steep slopes, and southeastern-facing slopes. In these areas, holes, large pits, and spikes were generated by the software during the correlation process and the automatic interpolation method. To eliminate these problems, overlapping DEMs were generated and filtered using a progressive morphologic filter. The quadrangles used to delineate the DEMs in the publication were derived from the Afghan Geodesy and Cartography Head Office's (AGCHO) 1:100,000-scale maps series quadrangles. Each DEM was clipped and assigned a name according to the associated AGCHO quadrangle name. The geospatial data included in this publication are intended to be used with any GIS software packages including, but not limited to, ESRI's ArcGIS and ERDAS IMAGINE.
Distributed temperature sensor testing in liquid sodium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerardi, Craig; Bremer, Nathan; Lisowski, Darius
Rayleigh-backscatter-based distributed fiber optic sensors were immersed in sodium to obtain high-resolution liquid-sodium temperature measurements. Distributed temperature sensors (DTSs) functioned well up to 400°C in a liquid sodium environment. The DTSs measured sodium column temperature and the temperature of a complex geometrical pattern that leveraged the flexibility of fiber optics. A single Ø 360 lm OD sensor registered dozens of temperatures along a length of over one meter at 100 Hz. We also demonstrated the capability to use a single DTS to simultaneously detect thermal interfaces (e.g. sodium level) and measure temperature.
ERIC Educational Resources Information Center
Smith-Yoshimura, Karen; Altman, Micah; Conlon, Michael; Cristán, Ana Lupe; Dawson, Laura; Dunham, Joanne; Hickey, Thom; Hill, Amanda; Hook, Daniel; Horstmann, Wolfram; MacEwan, Andrew; Schreur, Philip; Smart, Laura; Wacker, Melanie; Woutersen, Saskia
2014-01-01
The OCLC Research Report, "Registering Researchers in Authority Files", [Accessible in ERIC as ED564924] summarizes the results of the research conducted by the OCLC Research Registering Researchers in Authority Files Task Group in 2012-2014. Details of this research are in supplementary data sets: (1) "Supplement A: Use Cases. A…
NASA Technical Reports Server (NTRS)
Ambrosia, Vincent G.; Myers, Jeffrey S.; Ekstrand, Robert E.; Fitzgerald, Michael T.
1991-01-01
A simple method for enhancing the spatial and spectral resolution of disparate data sets is presented. Two data sets, digitized aerial photography at a nominal spatial resolution 3,7 meters and TMS digital data at 24.6 meters, were coregistered through a bilinear interpolation to solve the problem of blocky pixel groups resulting from rectification expansion. The two data sets were then subjected to intensity-saturation-hue (ISH) transformations in order to 'blend' the high-spatial-resolution (3.7 m) digitized RC-10 photography with the high spectral (12-bands) and lower spatial (24.6 m) resolution TMS digital data. The resultant merged products make it possible to perform large-scale mapping, ease photointerpretation, and can be derived for any of the 12 available TMS spectral bands.
A m-ary linear feedback shift register with binary logic
NASA Technical Reports Server (NTRS)
Perlman, M. (Inventor)
1973-01-01
A family of m-ary linear feedback shift registers with binary logic is disclosed. Each m-ary linear feedback shift register with binary logic generates a binary representation of a nonbinary recurring sequence, producible with a m-ary linear feedback shift register without binary logic in which m is greater than 2. The state table of a m-ary linear feedback shift register without binary logic, utilizing sum modulo m feedback, is first tubulated for a given initial state. The entries in the state table are coded in binary and the binary entries are used to set the initial states of the stages of a plurality of binary shift registers. A single feedback logic unit is employed which provides a separate feedback binary digit to each binary register as a function of the states of corresponding stages of the binary registers.
Bradley, J S; Phillips, J O; Cavanaugh, J E; Metzler, M H
1998-11-01
To evaluate the clinical utility of measuring gastric pH with a pH meter vs. pH paper in critical care patients. Prospective comparison of gastric pH measurements, using both pH meter and pH paper. Surgical intensive care unit (ICU) at a rural Midwestern university medical center. Fifty-one patients who received therapy for prophylaxis of stress ulcers in the surgical ICU. Therapy for stress ulcer prophylaxis was monitored. The pH of 985 gastric samples, taken from 51 patients, was measured with both pH meter and pH paper. The pH meter and pH paper measures demonstrated a concordance correlation coefficient of .896. The mean difference between the two measures (pH paper - pH meter) was estimated to be between -0.4 and 1.4, suggesting a positive bias for the paper. The prevalence of events representing clinically relevant differences between the pH meter and pH paper in the measurement of the same gastric sample was calculated. The frequency with which each of the events occurred consecutively (or, in one case, two nearly consecutive events on the same day) was also calculated. Bias in a clinically relevant range was estimated. A set of "probability profiles" was constructed. A hand-held pH meter and pH paper are not interchangeable measures of gastric pH. The pH paper exhibits an appreciable positive bias compared with a hand-held pH meter in the clinically relevant range of 2 to 6. More research is needed to determine if that bias affects treatment outcomes. We recommend the use of a pH meter for patients who demonstrate pH readings of < or = 4, consecutive with readings of < or = 5.
NASA Technical Reports Server (NTRS)
Fijany, Amir (Inventor); Bejczy, Antal K. (Inventor)
1994-01-01
In a computer having a large number of single-instruction multiple data (SIMD) processors, each of the SIMD processors has two sets of three individual processor elements controlled by a master control unit and interconnected among a plurality of register file units where data is stored. The register files input and output data in synchronism with a minor cycle clock under control of two slave control units controlling the register file units connected to respective ones of the two sets of processor elements. Depending upon which ones of the register file units are enabled to store or transmit data during a particular minor clock cycle, the processor elements within an SIMD processor are connected in rings or in pipeline arrays, and may exchange data with the internal bus or with neighboring SIMD processors through interface units controlled by respective ones of the two slave control units.
Household Energy Consumption Segmentation Using Hourly Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwac, J; Flora, J; Rajagopal, R
2014-01-01
The increasing US deployment of residential advanced metering infrastructure (AMI) has made hourly energy consumption data widely available. Using CA smart meter data, we investigate a household electricity segmentation methodology that uses an encoding system with a pre-processed load shape dictionary. Structured approaches using features derived from the encoded data drive five sample program and policy relevant energy lifestyle segmentation strategies. We also ensure that the methodologies developed scale to large data sets.
Direct Methanol Fuel Cell (DMFC) Battery Replacement Program
2013-01-29
selection of the Reynold’s number enables use of water for simulation of gas or liquid flow. Introduction of dye to the flow stream, with video...calibrated using a soap -film flow meter (Bubble-o-meter, Dublin, OH). Eleven Array system temperature regions were set as follows prior to start of...expected. The ar- ray flow proceeds down the columns: column effects would be more likely than row effects from a design of experiments perspective
The changing roles of registered nurses in Pioneer Accountable Care Organizations.
Pittman, Patricia; Forrest, Emily
2015-01-01
This study focuses on whether and how Pioneer Accountable Care Organization (ACO) leaders believe the deployment of the registered nurse workforce is changing in response to the shared savings incentives. Semistructured phone interviews with leaders from 18 of the original 32 Pioneer ACOs were conducted. Narrative analysis suggests that all of the organizations are developing new and enhanced roles for registered nurses across the continuum of care. Overall, eight types of changes were reported: enhancement of roles, substitution, delegation, increased numbers of nurses, relocation of services, transfer of nurses from one setting to another, the use of liaison nurses across settings, and partnerships between nurses coordinating care in primary and acute care settings. This exploratory study suggests that Pioneer ACO leaders believe that payment models are affecting the deployment of the health workforce and that these changes are, in turn, driving outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.
Nurses' experiences working with nursing students in a hospital: a phenomenological enquiry.
Lapeña-Moñux, Yolanda Raquel; Cibanal-Juan, Luis; Orts-Cortés, M Isabel; Maciá-Soler, M Loreto; Palacios-Ceña, Domingo
2016-01-01
this paper explores the experiences of registered nurses working with Spanish nursing students within the hospital. a qualitative phenomenological approach was followed. Purposeful sampling was employed. Twenty-one registered nurses, from a public hospital located in Spain, were included in the study. Data were collected by means of unstructured and semi-structured interviews and were analysed using Giorgi's proposal. The Consolidated Criteria for Reporting Qualitative Research were followed. three main themes described the experience of registered nurses: "The nurse's relationship with nursing students"; most nurses emphasized the importance of the first contact with students and they considered students' attitude to be key. "Defining the role of the student in clinical practice"; it is necessary to unify the nurse's role and interventions to avoid misleading students and establish priorities in clinical practice. "Building bridges between clinical settings and the University"; the need to establish a common ground and connection between the university and hospital clinical settings was emphasized. Nurses felt that the training program should also be designed by the clinical settings themselves. understanding the meaning of nursing students with registered nurses might gain a deeper insight into their expectations.
Lartey, Sarah; Cummings, Greta; Profetto-McGrath, Joanne
2014-11-01
The aim of this review was to report the effectiveness of strategies for retaining experienced Registered Nurses. Nursing researchers have noted that the projected nursing shortage, if not rectified, is expected to affect healthcare cost, job satisfaction and quality patient care. Retaining experienced nurses would help to mitigate the shortage, facilitate the transfer of knowledge and provision of quality care to patients. A systematic review of studies on interventions that promote the retention of experienced Registered Nurses in health care settings. Twelve studies were included in the final analysis. Most studies reported improved retention as a result of the intervention. Team work and individually targeted strategies including mentoring, leadership interest and in-depth orientation increased job satisfaction and produced higher retention results. Few published studies have examined interventions that promote the retention of experienced Registered Nurses in healthcare. Retention was highest when multiple interventions were used. Further research is needed to inform nurse leaders of ways to retain nurses and to maintain quality care in health care settings. Programmes targeting the retention of experienced nurses need to be considered when implementing measures to decrease the nursing shortage and its effects on quality care. © 2013 John Wiley & Sons Ltd.
Rasmussen, A; Frimodt-Møller, N; Espersen, F; Roed, M; Frimodt-Møller, C
1996-08-01
To compare three different urine metering systems for their ability to prevent retrograde contamination in an in vitro model of a closed urinary drainage system and for qualities important to their practical handling in a clinical setting. Using three urine-meters (the Braun Ureofix 511, the Kendall Curity 4000 and the Unoplast Unometer 500) the in vitro model was constantly flushed with a solution of Mueller-Hinton broth diluted with saline. On the first day, the urine collecting bag was inoculated with 10(8) cells of Pseudomonas aeruginosa. The system was operated for 12 days with daily sampling of the model bladder to detect any contamination. After 12 days the experiment was stopped and sampling performed at various locations, including the urine-meter and the tubing. Nine of each type of urine-meter were tested, i.e. three in three different experiments. In the clinical study, 45 patients were randomized to each of the three urine-meters and the nurses attending them were asked to complete a questionnaire on the practical handling of the urine-meters. When the urine-meters was omitted from the model system, the 'bladder' became contaminated with the test bacteria within 3 days. None of the nine Unometer 500 systems became contaminated, compared with four of each of the other two systems (P < 0.05). In clinical use, the Unometer 500 and Ureofix 511 were easier to suspend and empty than was the Curity 4000. The Unometer 500 was significantly easier to handle when the collecting bag was emptied. Urine-meters can prevent retrograde contamination in a closed bladder-drainage model, but the degree of prevention depends upon the type of urine-meter. In daily practice, there were differences in the ease of suspension of the systems and in the emptying of the urine-meter and collecting bag.
The utility of blood glucose meters in biotechnological applications.
FitzGerald, Jennifer; Vermerris, Wilfred
2005-06-01
Most methods used to measure glucose concentrations in biotechnological settings are labour-intensive and/or expensive. With this in mind we have investigated the possibility of employing blood glucose meters, the use of which has the benefit of being fast, convenient and inexpensive, for this purpose. Accu-Chek Advantage (Roche Diagnostics, Indianapolis, IN, U.S.A.) and Precision QID (Medisense, Abbott Laboratories, Indianapolis, IN, U.S.A.) meters were tested using glucose samples of known concentration, at pH 7.5 and 4.8. The Accu-Chek Advantage meter uses strips containing the enzyme glucose dehydrogenase. This meter showed a linear response for glucose concentrations between 0.50 and 6.0 g/litre, and the effect of pH was small. The Precision QID meter uses strips containing the enzyme glucose oxidase and is more sensitive to pH. The displayed glucose concentrations at low pH values were consistently lower than at higher pH values. At both pH values the response curve reached a plateau, which limited the effective range of this meter to a range of 0.30-2.5 g/litre. Unlike the Precision QID meter, the Accu-Chek Advantage meter also responded to xylose and arabinose. A synergistic effect of combining sugars was observed when a mixture of sugars consisting of glucose and arabinose, or glucose and xylose, was applied: the displayed concentrations were consistently higher than was expected on the basis of the individual calibration curves. The use of glucose meters is a fast and convenient alternative to existing methods and may be of particular use for screening purposes where a high degree of accuracy is not crucial. The choice of meter should depend on the application, and in this respect the pH, expected concentration range and the presence of other sugars are among the factors that should be considered.
Balion, Cynthia; Grey, Vijaylaxmi; Ismaila, Afisi; Blatz, Susan; Seidlitz, Wendy
2006-11-03
Point of care (POC) glucose meters are routinely used as a screening tool for hypoglycemia in a neonatal setting. Glucose meters however, lack the same accuracy as laboratory instruments for glucose measurement. In this study we investigated potential reasons for this inaccuracy and established a cut off value for confirmatory testing. In this prospective study, all patients in the neonatal intensive care unit who had a plasma glucose test ordered were eligible to participate. Demographic information, sample collection information (nine variables) and a recent hematocrit value were recorded for each sample. Glucose measurements were taken at the bedside on the glucose meter (RN PCx) as well as in the laboratory on both the glucose meter (LAB PCx) and the laboratory analyzer (PG). Data were analyzed by simple and mixed-effects regression analysis and by analysis of a receiver operator characteristics (ROC) curve. There were 475 samples analyzed from 132 patients. RN PCx values were higher than PG values (mean = 4.9%), while LAB PCx results were lower (mean = -5.2%) than PG values. Only 31% of the difference between RN PCx--PG and 46% of the difference for LAB PCx--PG could be accounted for by the variables tested. The largest proportion of variance between PCx and PG measurements was explained by hematocrit (about 30%) with a greater effect seen at glucose concentrations < or =4.0 mmol/L (< or =72 mg/dL)(48% and 40% for RN PCx and LAB PCx, respectively). The ROC analysis showed that for detection of all cases of hypoglycemia (PG < 2.6 mmol/L)(PG < 47 mg/dL) the PCx screening cut off value would need to be set at 3.8 mmol/L (68 mg/dL) requiring 20% of all samples to have confirmatory analysis by the laboratory method. The large difference between glucose results obtained by PCx glucose meter compared to the laboratory analyzer can be explained in part by hematocrit and low glucose concentration. These results emphasize that the glucose meter is useful only as a screening device for neonatal hypoglycemia and that a screening cut off value must be established.
Johnson, Michaela R.; Clark, Jimmy M.; Dickinson, Ross G.; Sanocki, Chris A.; Tranmer, Andrew W.
2009-01-01
This data set was developed as part of the National Water-Quality Assessment (NAWQA) Program, Nutrient Enrichment Effects Topical (NEET) study. This report is concerned with three of the eight NEET study units distributed across the United States: Ozark Plateaus, Upper Mississippi River Basin, and Upper Snake River Basin, collectively known as Group II of the NEET study. Ninety stream reaches were investigated during 2006-08 in these three study units. Stream segments, with lengths equal to the base-10 logarithm of the basin area, were delineated upstream from the stream reaches through the use of digital orthophoto quarter-quadrangle (DOQQ) imagery. The analysis area for each stream segment was defined by a streamside buffer extending laterally to 250 meters from the stream segment. Delineation of landuse and land-cover (LULC) map units within stream-segment buffers was completed using on-screen digitizing of riparian LULC classes interpreted from the DOQQ. LULC units were classified using a strategy consisting of nine classes. National Wetlands Inventory (NWI) data were used to aid in wetland classification. Longitudinal riparian transects (lines offset from the stream segments) were generated digitally, used to sample the LULC maps, and partitioned in accord with the intersected LULC map-unit types. These longitudinal samples yielded the relative linear extent and sequence of each LULC type within the riparian zone at the segment scale. The resulting areal and linear estimates of LULC extent filled in the spatial-scale gap between the 30-meter resolution of the 1990s National Land Cover Dataset and the reach-level habitat assessment data collected onsite routinely for NAWQA ecological sampling. The resulting data consisted of 12 geospatial data sets: LULC within 25 meters of the stream reach (polygon); LULC within 50 meters of the stream reach (polygon); LULC within 50 meters of the stream segment (polygon); LULC within 100 meters of the stream segment (polygon); LULC within 150 meters of the stream segment (polygon); LULC within 250 meters of the stream segment (polygon); frequency of gaps in woody vegetation at the reach scale (arc); stream reaches (arc); longitudinal LULC transect sample at the reach scale (arc); frequency of gaps in woody vegetation at the segment scale (arc); stream segments (arc); and longitudinal LULC transect sample at the segment scale (arc).
Soil Moisture Estimation Using Hyperspectral SWIR Imagery
NASA Astrophysics Data System (ADS)
Lewis, D.
2007-12-01
The U.S. Geological Survey (USGS) is engaged with the U.S. Department of Agriculture's (USDA) Agricultural Research Service (ARS) and the University of Georgia's National Environmentally Sound Production Agriculture Laboratory (NESPAL) both in Tifton, Georgia, USA, to develop transformations for medium and high resolution remotely sensed images to generate moisture indicators for soil. The Institute for Technology Development (ITD) is located at the Stennis Space Center in southern Mississippi and has developed hyperspectral sensor systems that, when mounted in aircraft, collect electromagnetic reflectance data of the terrain. The sensor suite consists of sensors for three different sections of the electromagnetic spectrum; the Ultra-Violet (UV), Visible/Near InfraRed (VNIR) and Short Wave InfraRed (SWIR). The USDA/ ARS' Southeast Watershed Research Laboratory has probes that measure and record soil moisture. Data taken from the ITD SWIR sensor and the USDA/ARS soil moisture meters were analyzed to study the informatics relationships between SWIR data and measured soil moisture. The geographic locations of 29 soil moisture meters provided by the USDA/ARS are in the vicinity of Tifton, Georgia. Using USGS Digital Ortho Quads (DOQ), flightlines were drawn over the 29 soil moisture meters. The SWIR sensor was installed into an aircraft. The coordinates for the flightlines were also loaded into the navigational system of the aircraft. This airborne platform was used to collect the data over these flightlines. In order to prepare the data set for analysis, standard preprocessing was performed. These standard processes included sensor calibration, spectral subsetting, and atmospheric calibration. All 60 bands of the SWIR data were collected for each line in the image data, 15 bands of which were stripped from the data set leaving 45 bands of information in the wavelength range of 906 to 1705 nanometers. All the image files were calibrated using the regression equations generated by using radiometer data collected over calibration tarps. Regions of Interest (ROI) were drawn over the image data set corresponding with the location of the soil moisture meters. Scripts written in ENVI's Interactive Data Language (IDL) were developed to extract the spectra from each of the processed hyperspectral image data over each soil moisture meter from its corresponding ROI. The informatics relationship between soil moisture and SWIR spectra was identified by using the resulting data set.
Analytical and Clinical Performance of Blood Glucose Monitors
Boren, Suzanne Austin; Clarke, William L.
2010-01-01
Background The objective of this study was to understand the level of performance of blood glucose monitors as assessed in the published literature. Methods Medline from January 2000 to October 2009 and reference lists of included articles were searched to identify eligible studies. Key information was abstracted from eligible studies: blood glucose meters tested, blood sample, meter operators, setting, sample of people (number, diabetes type, age, sex, and race), duration of diabetes, years using a glucose meter, insulin use, recommendations followed, performance evaluation measures, and specific factors affecting the accuracy evaluation of blood glucose monitors. Results Thirty-one articles were included in this review. Articles were categorized as review articles of blood glucose accuracy (6 articles), original studies that reported the performance of blood glucose meters in laboratory settings (14 articles) or clinical settings (9 articles), and simulation studies (2 articles). A variety of performance evaluation measures were used in the studies. The authors did not identify any studies that demonstrated a difference in clinical outcomes. Examples of analytical tools used in the description of accuracy (e.g., correlation coefficient, linear regression equations, and International Organization for Standardization standards) and how these traditional measures can complicate the achievement of target blood glucose levels for the patient were presented. The benefits of using error grid analysis to quantify the clinical accuracy of patient-determined blood glucose values were discussed. Conclusions When examining blood glucose monitor performance in the real world, it is important to consider if an improvement in analytical accuracy would lead to improved clinical outcomes for patients. There are several examples of how analytical tools used in the description of self-monitoring of blood glucose accuracy could be irrelevant to treatment decisions. PMID:20167171
47 CFR 2.1511 - Measurements of radiated emissions.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) General set-up instructions. Measurements of radiated electromagnetic emissions (EME) are to be performed... meters in both vertical and horizontal polarization. Record the highest receiver reading in dBm as the... receiver reading in dBm and the instrument settings, antenna height and direction for maximum radiation...
40 CFR 53.2 - General requirements for a reference method determination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... part. Further, FRM samplers must be manufactured in an ISO 9001-registered facility, as defined in § 53... manufactured in an ISO 9001-registered facility, as defined in § 53.1 and as set forth in § 53.51. (b...
A note on chaotic unimodal maps and applications.
Zhou, C T; He, X T; Yu, M Y; Chew, L Y; Wang, X G
2006-09-01
Based on the word-lift technique of symbolic dynamics of one-dimensional unimodal maps, we investigate the relation between chaotic kneading sequences and linear maximum-length shift-register sequences. Theoretical and numerical evidence that the set of the maximum-length shift-register sequences is a subset of the set of the universal sequence of one-dimensional chaotic unimodal maps is given. By stabilizing unstable periodic orbits on superstable periodic orbits, we also develop techniques to control the generation of long binary sequences.
A 32-bit NMOS microprocessor with a large register file
NASA Astrophysics Data System (ADS)
Sherburne, R. W., Jr.; Katevenis, M. G. H.; Patterson, D. A.; Sequin, C. H.
1984-10-01
Two scaled versions of a 32-bit NMOS reduced instruction set computer CPU, called RISC II, have been implemented on two different processing lines using the simple Mead and Conway layout rules with lambda values of 2 and 1.5 microns (corresponding to drawn gate lengths of 4 and 3 microns), respectively. The design utilizes a small set of simple instructions in conjunction with a large register file in order to provide high performance. This approach has resulted in two surprisingly powerful single-chip processors.
Heimes, F.J.; Luckey, R.R.; Stephens, D.M.
1986-01-01
Combining estimates of applied irrigation water, determined for selected sample sites, with information on irrigated acreage provides one alternative for developing areal estimates of groundwater pumpage for irrigation. The reliability of this approach was evaluated by comparing estimated pumpage with metered pumpage for two years for a three-county area in southwestern Nebraska. Meters on all irrigation wells in the three counties provided a complete data set for evaluation of equipment and comparison with pumpage estimates. Regression analyses were conducted on discharge, time-of-operation, and pumpage data collected at 52 irrigation sites in 1983 and at 57 irrigation sites in 1984 using data from inline flowmeters as the independent variable. The standard error of the estimate for regression analysis of discharge measurements made using a portable flowmeter was 6.8% of the mean discharge metered by inline flowmeters. The standard error of the estimate for regression analysis of time of operation determined from electric meters was 8.1% of the mean time of operation determined from in-line and 15.1% for engine-hour meters. Sampled pumpage, calculated by multiplying the average discharge obtained from the portable flowmeter by the time of operation obtained from energy or hour meters, was compared with metered pumpage from in-line flowmeters at sample sites. The standard error of the estimate for the regression analysis of sampled pumpage was 10.3% of the mean of the metered pumpage for 1983 and 1984 combined. The difference in the mean of the sampled pumpage and the mean of the metered pumpage was only 1.8% for 1983 and 2.3% for 1984. Estimated pumpage, for each county and for the study area, was calculated by multiplying application (sampled pumpage divided by irrigated acreages at sample sites) by irrigated acreage compiled from Landsat (Land satellite) imagery. Estimated pumpage was compared with total metered pumpage for each county and the study area. Estimated pumpage by county varied from 9% less, to 20% more, than metered pumpage in 1983 and from 0 to 15% more than metered pumpage in 1984. Estimated pumpage for the study area was 11 % more than metered pumpage in 1983 and 5% more than metered pumpage in 1984. (Author 's abstract)
Physical and Radiative Characteristics and Long Term Variability of the Okhotsk Sea Ice Cover
NASA Technical Reports Server (NTRS)
Nishio, Fumihiko; Comiso, Josefino C.; Gersten, Robert; Nakayama, Masashige; Ukita, Jinro; Gasiewski, Al; Stanko, Boba; Naoki, Kazuhiro
2007-01-01
Much of what we know about the large scale characteristics of the Okhotsk Sea ice cover comes from ice concentration maps derived from passive microwave data. To understand what these satellite data represents in a highly divergent and rapidly changing environment like the Okhotsk Sea, we analyzed concurrent satellite, aircraft, and ship data and characterized the sea ice cover at different scales from meters to tens of kilometers. Through comparative analysis of surface features using co-registered data from visible, infrared and microwave channels we evaluated how the general radiative and physical characteristics of the ice cover changes as well as quantify the distribution of different ice types in the region. Ice concentration maps from AMSR-E using the standard sets of channels, and also only the 89 GHz channel for optimal resolution, are compared with aircraft and high resolution visible data and while the standard set provides consistent results, the 89 GHz provides the means to observe mesoscale patterns and some unique features of the ice cover. Analysis of MODIS data reveals that thick ice types represents about 37% of the ice cover indicating that young and new ice represent a large fraction of the lice cover that averages about 90% ice concentration, according to passive microwave data. A rapid decline of -9% and -12 % per decade is observed suggesting warming signals but further studies are required because of aforementioned characteristics and because the length of the ice season is decreasing by only 2 to 4 days per decade.
Hydrogen Field Test Standard: Laboratory and Field Performance
Pope, Jodie G.; Wright, John D.
2015-01-01
The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors < 0.1 % and < 0.04 % in the PVT and master meter methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are used. PMID:26722192
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, Ksenia; Nichols, James H.
2009-01-01
Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy, anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results. PMID:20144348
GIS integration of the 1:2880 Stabile cadastre map sheets from Bukovina
NASA Astrophysics Data System (ADS)
Crǎciunescu, Vasile; NièU, Constantin; Timár, Gábor; Boicu, Alin; Rus, Ioan
2010-05-01
Starting with 1975, the North-West part of the Moldavia Principality was occupied by the Habsburg Monarchy and become known as Duchy of Bukovina. During the 143 years of Austrian rule (1775 - 1918), this territory was the subject of several topographic and cadastral surveys. The paper will focus on the cadastral maps produced under the Stabile cadaster (also known as Franciscan cadastre). In the Habsburg Empire, this cadastral survey was started in 1817, at an order of the Emperor Francis I of Austria, as a base for his land taxation reform. In Bukovina, the land registration system was introduced in 1832. The base maps, known as Katastralmappe or Parzellenplan, were drawn under the 1:2880 scale, using Viennese Klafter (fathom) as length unit (1 Viennese Klafter = 1.89648 meters). Each taxation parish (usually centered on the most important cities/villages) was surveyed and mapped individually. The map sheets were accompanied by several registers (e.g. register of building plots, register of land plots) with informations regarding the cadastral parcels. Today, such documents represent a valuable resource in reconstructing the natural and built environment. The study presents the way this maps can be georeferenced and integrated into modern GIS applications, for precise digitization, spatial analysis and 3D reconstruction. The base of the georeference is the knowledge of the projection and datum parameters of the survey in Bukovina as well as the sheet labeling system.
Anisotropy of the permittivity field inferred from aspect-sensitive radar echoes
NASA Technical Reports Server (NTRS)
Waterman, A. T.
1984-01-01
An attempt is made to draw some quantitative conclusions regarding the anisotropy of the clear-air back-scattering mechanism based on the measured variation of echo power with zenith angle. The measurements were made by the SOUSY group of the Max Planck Institute for Aeronomy at Lindau, FRG. They installed their 47-MHz transmitter and antenna feed in the 300-meter diameter reflector at Arecibo. The resulting 1.7-degree beam was stepped successively through seven 1.7-degree intervals from 1.7 to 11.7 degrees in zenith angle, obtaining about four minutes of data at each setting. This procedure was carried out in an eastward pointing azimuth and in a northward pointing azimuth, the entire set of measurements consuming an hour and twenty minutes. Range resolution was 150 meters.
Skin Friction Measurements Using Luminescent Oil Films
NASA Astrophysics Data System (ADS)
Husen, Nicholas M.
As aircraft are designed to a greater extent on computers, the need for accurate and fast CFD algorithms has never been greater. The development of CFD algorithms requires experimental data against which CFD output can be validated and from which insight about flow physics can be acquired. Skin friction, in particular, is an important quantity to predict with CFD, and experimental skin friction data sets aid not only with the validation of the CFD predictions, but also in tuning the CFD models to predict specific flow fields. However, a practical experimental technique for collecting spatially and temporally resolved skin friction data on complex models does not yet exist. This dissertation develops and demonstrates a new luminescent oil film skin friction meter which can produce spatially-resolved quantitative steady and unsteady skin friction data on models with complex curvature. The skin friction acting on the surface of a thin film of oil can be approximated by the expression tauw =mu ouh/h, where mu o is the dynamic viscosity of the oil, uh is the velocity of the surface of the oil film, and h is the thickness of the oil film. The new skin friction meter determines skin friction by measuring h and uh. The oil film thickness h is determined by ratioing the intensity of the fluorescent emissions from the oil film with the intensity of the incident light which is scattered from the surface of the model. When properly calibrated, that ratio provides an absolute oil film thickness value. This oil film thickness meter is therefore referred as the Ratioed-Image Film-Thickness (RIFT) Meter. The oil film velocity uh is determined by monitoring the evolution of tagged molecules within the oil film: Photochromic molecules are dissolved into the fluorescent oil and a pattern is written into the oil film using an ultraviolet laser. The evolution of the pattern is recorded, and standard cross-correlation techniques are applied to the resulting sequence of images. This newly developed skin friction meter is therefore called the Luminescent Oil Film Flow-Tagging skin friction meter, or the LOFFT skin friction meter. The LOFFT skin friction meter is demonstrated by collecting time-averaged skin friction measurements on NASA's FAITH model and by collecting unsteady skin friction measurements with a frequency response of 600Hz. Higher frequency response is possible and is dependent on the experimental setup. This dissertation also contributes to the work done on the Global Luminescent Oil Film Skin Friction Meter (GLOFSFM) by noting that the technique could be influenced by ripples at the oil-air interface. An experiment studying the evolution of ripples at the oil-air interface was conducted to determine under what oil film conditions the GLOFSFM can be appropriately applied. The RIFT meter was crucial for this experiment, as it facilitated quantitative distributed oil film thickness measurements during the wind-tunnel run. The resulting data set is rich in content, permitting the computation of mean wavelengths, peak-to-trough ripple heights, wave speeds, and mean thicknesses. In addition to determining under what oil film conditions the GLOFSFM may be applied, this experiment directly determined the oil film conditions under which the velocity of the ripples may be used to proxy the velocity of the oil film surface. The RIFT meter and the ability to determine oil film surface velocity by monitoring ripple velocities admit yet another time-averaged skin friction meter, the Fluorescent-Oil Ripple-Velocity (FORV) skin friction meter. The FORV skin friction meter recovers skin friction as tau w = muovrip/H, where vrip is the velocity of the ripples, and H is the oil film thickness averaged over the thickness fluctuations due to the ripples. The FORV skin friction meter is demonstrated on NASA's FAITH model.
Mwashote, B.M.; Burnett, W.C.; Chanton, J.; Santos, I.R.; Dimova, N.; Swarzenski, P.W.
2010-01-01
Submarine groundwater discharge (SGD) assessments were conducted both in the laboratory and at a field site in the northeastern Gulf of Mexico, using a continuous heat-type automated seepage meter (seepmeter). The functioning of the seepmeter is based on measurements of a temperature gradient in the water between downstream and upstream positions in its flow pipe. The device has the potential of providing long-term, high-resolution measurements of SGD. Using a simple inexpensive laboratory set-up, we have shown that connecting an extension cable to the seepmeter has a negligible effect on its measuring capability. Similarly, the observed influence of very low temperature (???3 ??C) on seepmeter measurements can be accounted for by conducting calibrations at such temperatures prior to field deployments. Compared to manual volumetric measurements, calibration experiments showed that at higher water flow rates (>28 cm day-1 or cm3 cm-2 day-1) an analog flowmeter overestimated flow rates by ???7%. This was apparently due to flow resistance, turbulence and formation of air bubbles in the seepmeter water flow tubes. Salinity had no significant effect on the performance of the seepmeter. Calibration results from fresh water and sea water showed close agreement at a 95% confidence level significance between the data sets from the two media (R2 = 0.98). Comparatively, the seepmeter SGD measurements provided data that are comparable to manually-operated seepage meters, the radon geochemical tracer approach, and an electromagnetic (EM) seepage meter. ?? 2009 Elsevier Ltd.
Barriers to Research Utilization by Certified Registered Nurse Anesthetists
ERIC Educational Resources Information Center
Palmer, Timothy J.
2013-01-01
At present, no documentation pertaining to the factors influencing utilization of research into clinical practice by Certified Registered Nurse Anesthetists (CRNAs) exists. An investigation was undertaken to determine perceptions of CRNAs regarding factors within the context of the work setting, which may serve to influence their utilization of…
Jones, K P; Mullee, M A
1990-01-01
OBJECTIVE--To compare measurements of the peak expiratory flow rate taken by the mini Wright peak flow meter and the turbine spirometer. DESIGN--Pragmatic study with randomised order of use of recording instruments. Phase 1 compared a peak expiratory flow type expiration recorded by the mini Wright peak flow meter with an expiration to forced vital capacity recorded by the turbine spirometer. Phase 2 compared peak expiratory flow type expirations recorded by both meters. Reproducibility was assessed separately. SETTING--Routine surgeries at Aldermoor Health Centre, Southampton. SUBJECTS--212 Patients aged 4 to 78 presenting with asthma or obstructive airways disease. Each patient contributed only once to each phase (105 in phase 1, 107 in phase 2), but some entered both phases on separate occasions. Reproducibility was tested on a further 31 patients. MAIN OUTCOME MEASURE--95% Limits of agreement between measurements on the two meters. RESULTS--208 (98%) Of the readings taken by the mini Wright meter were higher than the corresponding readings taken by the turbine spirometer, but the 95% limits of agreement (mean difference (2 SD] were wide (1 to 173 l/min). Differences due to errors in reproducibility were not sufficient to predict this level of disagreement. Analysis by age, sex, order of use, and the type of expiration did not detect any significant differences. CONCLUSIONS--The two methods of measuring peak expiratory flow rate were not comparable. The mini Wright meter is likely to remain the preferred instrument in general practice. PMID:2142611
Heap/stack guard pages using a wakeup unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gooding, Thomas M; Satterfield, David L; Steinmacher-Burow, Burkhard
A method and system for providing a memory access check on a processor including the steps of detecting accesses to a memory device including level-1 cache using a wakeup unit. The method includes invalidating level-1 cache ranges corresponding to a guard page, and configuring a plurality of wakeup address compare (WAC) registers to allow access to selected WAC registers. The method selects one of the plurality of WAC registers, and sets up a WAC register related to the guard page. The method configures the wakeup unit to interrupt on access of the selected WAC register. The method detects access ofmore » the memory device using the wakeup unit when a guard page is violated. The method generates an interrupt to the core using the wakeup unit, and determines the source of the interrupt. The method detects the activated WAC registers assigned to the violated guard page, and initiates a response.« less
Automatic Focusing for a 675 GHz Imaging Radar with Target Standoff Distances from 14 to 34 Meters
NASA Technical Reports Server (NTRS)
Tang, Adrian; Cooper, Ken B.; Dengler, Robert J.; Llombart, Nuria; Siegel, Peter H.
2013-01-01
This paper dicusses the issue of limited focal depth for high-resolution imaging radar operating over a wide range of standoff distances. We describe a technique for automatically focusing a THz imaging radar system using translational optics combined with range estimation based on a reduced chirp bandwidth setting. The demonstarted focusing algorithm estimates the correct focal depth for desired targets in the field of view at unknown standoffs and in the presence of clutter to provide good imagery at 14 to 30 meters of standoff.
System and technology considerations for space-based air traffic surveillance
NASA Technical Reports Server (NTRS)
Vaisnys, A.
1986-01-01
This paper describes the system trade-offs examined in a recent study of space-based air traffic surveillance. Three system options, each satisfying a set of different constraints, were considered. The main difference in the technology needed to implement the three systems was determined to be the size of the spacecraft antenna aperture. It was found that essentially equivalent position location accuracy could be achieved with apertures from 50 meters down to less than a meter in diameter, depending on the choice of signal structure and on the desired user update rate.
Surveyor V: Television pictures
Shoemaker, E.M.; Batson, R.M.; Holt, H.E.; Morris, E.C.; Rennilson, J.J.; Whitaker, E.A.
1967-01-01
Surveyor V landed in a small crater, 8.5 meters wide and 12.5 meters long, which was probably formed by drainage of surficial fragmental debris into a subsurface fissure. The lunar surface debris layer is exposed in the walls of this crater. At depths below about 10 centimeters, the debris appears to be composed mainly of shock-compressed aggregates, ranging from a few millimeters up to 3 centimeters in diameter, set in a matrix of less-coherent finer particles. Rocky chips and fragments larger than a millimeter are dispersed as a subordinate constituent of the debris.
Visible to Near-infrared Spectral Reflectance, NGEE-Arctic Tram, Barrow, Alaska, 2015-2017
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meng, Ran; McMahon, Andrew; Rogers, Alistair
Canopy spectral reflectance collected from the NGEE-Arctic automated tram platform using a PP-Systems UniSpec-DC spectrometer. Downwelling radiance was measured using a 2 meter fiber optic cable connected to a cosine diffuser. Upwelling (i.e. reflected) radiance was measured using a 2 meter cable connected to a 12 degree field-of-view (FOV) lens. Canopy reflectance was calculated using the ratio of upwelling to downwelling radiance measured over a 99.99% reflectance Spectralon standard measured at the start of each measurement set.
46 CFR 31.10-5 - Inspection of new tank vessels-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... approved, properly stamped and dated and distributed as follows: One set to owner or builder; one set to....com. (2) For vessels of 100 meters (328 feet) or more in length contracted for on or after September 7... certificate of inspection endorsed as a permit for the carriage of flammable or combustible liquids in bulk...
31 CFR 352.3 - Registration and issue.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Registration and issue. 352.3 Section....3 Registration and issue. (a) Registration. Series HH bonds may be registered as set forth in.... 3-80. (b) Validity of issue. A bond is validly issued when it is registered as provided 31 CFR part...
Co-registered photoacoustic, thermoacoustic, and ultrasound mouse imaging
NASA Astrophysics Data System (ADS)
Reinecke, Daniel R.; Kruger, Robert A.; Lam, Richard B.; DelRio, Stephen P.
2010-02-01
We have constructed and tested a prototype test bed that allows us to form 3D photoacoustic CT images using near-infrared (NIR) irradiation (700 - 900 nm), 3D thermoacoustic CT images using microwave irradiation (434 MHz), and 3D ultrasound images from a commercial ultrasound scanner. The device utilizes a vertically oriented, curved array to capture the photoacoustic and thermoacoustic data. In addition, an 8-MHz linear array fixed in a horizontal position provides the ultrasound data. The photoacoustic and thermoacoustic data sets are co-registered exactly because they use the same detector. The ultrasound data set requires only simple corrections to co-register its images. The photoacoustic, thermoacoustic, and ultrasound images of mouse anatomy reveal complementary anatomic information as they exploit different contrast mechanisms. The thermoacoustic images differentiate between muscle, fat and bone. The photoacoustic images reveal the hemoglobin distribution, which is localized predominantly in the vascular space. The ultrasound images provide detailed information about the bony structures. Superposition of all three images onto a co-registered hybrid image shows the potential of a trimodal photoacoustic-thermoacoustic-ultrasound small-animal imaging system.
Comparison of two methods of measuring gastric pH.
Neill, K M; Rice, K T; Ahern, H L
1993-01-01
To assess the agreement between two methods of measuring gastric pH in critically ill patients (multiple band litmus paper-tested aspirations versus a meter-read probe located in the tip of a nasogastric tube) and to compare nurse satisfaction with both methods of measuring pH. Prospective, correlational, nonprobability sample. Mid-Atlantic, semirural Veterans Affairs Medical Center. 39 male, surgical, critical care patients, who were nasogastrically intubated in the operating room and received nothing by mouth. NURSES: Twenty-seven registered nurses on the medical-surgical intensive care staff. Differences in pH units as determined by two methods of measurement and nurse satisfaction scores. Litmus paper-tested aspirations versus a meter-read probe located in the tip of the nasogastric tube, measured every 2 hours for 48 hours. A nurse satisfaction assessment form for both measurement methods at entry, 6 months, and 12 months. All measures of association, Pearson's r (0.79), the concordance coefficient (0.74), and eta (0.88), were high. The concordance coefficient measures indicated sufficient agreement between the two methods at the initial and 24 hour measurement times (Cb) = 0.97, 0.97, and 0.94), but not at 48 hours. The meter method indicated prophylaxis was needed when the paper did not, more often than did the paper method (9.3% vs 5.2%). A significant difference between methods was found only at the last reading at 48 hours (z = -2.24, p < .0249). MANOVA revealed that nurses' preference for the meter method was significant (F = 139.48, df = 1.18) and increased over time (F = 4.77, df = 2,36). The gastric probe method of measuring pH is an accurate substitution up to 48 hours for the litmus-paper aspiration method in the postoperative patient who is receiving nothing by mouth. Nurses prefer the gastric probe method of measuring pH over the litmus-paper method because they judge it to be safer, faster, and more accurate.
Usability analysis of 2D graphics software for designing technical clothing.
Teodoroski, Rita de Cassia Clark; Espíndola, Edilene Zilma; Silva, Enéias; Moro, Antônio Renato Pereira; Pereira, Vera Lucia D V
2012-01-01
With the advent of technology, the computer became a working tool increasingly present in companies. Its purpose is to increase production and reduce the inherent errors in manual production. The aim of this study was to analyze the usability of 2D graphics software in creating clothing designs by a professional during his work. The movements of the mouse, keyboard and graphical tools were monitored in real time by software Camtasia 7® installed on the user's computer. To register the use of mouse and keyboard we used auxiliary software called MouseMeter®, which quantifies the number of times they pressed the right, middle and left mouse's buttons, the keyboard and also the distance traveled in meters by the cursor on the screen. Data was collected in periods of 15 minutes, 1 hour and 8 hours, consecutively. The results showed that the job is considered repetitive and high demands physical efforts, which can lead to the appearance of repetitive strain injuries. Thus, the goal of minimizing operator efforts and thereby enhance the usability of the examined tool, becomes imperative to replace the mouse by a device called tablet, which also offers an electronic pen and a drawing platform for design development.
Doub, William H; Shah, Vibhakar; Limb, Susan; Guo, Changning; Liu, Xiaofei; Ngo, Diem
2014-11-01
As a result of the Montreal Protocol on Substances that Deplete the Ozone Layer, manufacturers of metered dose inhalers began reformulating their products to use hydrofluoroalkanes (HFAs) as propellants in place of chlorofluorocarbons (CFCs). Although the new products are considered safe and efficacious by the US Food and Drug Administration (FDA), a large number of complaints have been registered via the FDA's Adverse Events Reporting System (FAERS)-more than 7000 as of May 2013. To develop a better understanding of the measurable parameters that may, in part, determine in vitro performance and thus patient compliance, we compared several CFC- and HFA-based products with respect to their aerodynamic performance in response to changes in actuator cleaning interval and interactuation delay interval. Comparison metrics examined in this study were: total drug delivered ex-actuator, fine particle dose (<5 μm), mass median aerodynamic diameter, plume width, plume temperature, plume impaction force, and actuator orifice diameter. Overall, no single metric or test condition distinguishes HFA products from CFC products, but, for individual products tested, there were a combination of metrics that differentiated one from another. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Bertrais, Sandrine; Boursier, Jérôme; Ducancelle, Alexandra; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Moal, Valérie; Calès, Paul
2017-06-01
There is currently no recommended time interval between noninvasive fibrosis measurements for monitoring chronic liver diseases. We determined how long a single liver fibrosis evaluation may accurately predict mortality, and assessed whether combining tests improves prognostic performance. We included 1559 patients with chronic liver disease and available baseline liver stiffness measurement (LSM) by Fibroscan, aspartate aminotransferase to platelet ratio index (APRI), FIB-4, Hepascore, and FibroMeter V2G . Median follow-up was 2.8 years during which 262 (16.8%) patients died, with 115 liver-related deaths. All fibrosis tests were able to predict mortality, although APRI (and FIB-4 for liver-related mortality) showed lower overall discriminative ability than the other tests (differences in Harrell's C-index: P < 0.050). According to time-dependent AUROCs, the time period with optimal predictive performance was 2-3 years in patients with no/mild fibrosis, 1 year in patients with significant fibrosis, and <6 months in cirrhotic patients even in those with a model of end-stage liver disease (MELD) score <15. Patients were then randomly split in training/testing sets. In the training set, blood tests and LSM were independent predictors of all-cause mortality. The best-fit multivariate model included age, sex, LSM, and FibroMeter V2G with C-index = 0.834 (95% confidence interval, 0.803-0.862). The prognostic model for liver-related mortality included the same covariates with C-index = 0.868 (0.831-0.902). In the testing set, the multivariate models had higher prognostic accuracy than FibroMeter V2G or LSM alone for all-cause mortality and FibroMeter V2G alone for liver-related mortality. The prognostic durability of a single baseline fibrosis evaluation depends on the liver fibrosis level. Combining LSM with a blood fibrosis test improves mortality risk assessment. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
NASA Astrophysics Data System (ADS)
Satyanarayana, B.; Majumder, G.; Mondal, N. K.; Kalmani, S. D.; Shinde, R. R.; Joshi, A.
2014-10-01
Pilot unit of a closed loop gas mixing and distribution system for the INO project was designed and is being operated with 1.8meters × 1.9meters RPCs for about two years. A number of studies on controlling the flow and optimisation of the gas mixture through the RPC stack were carried out during this period. The gas system essentially measures and attempts to maintain absolute pressure inside the RPC gas volume. During typical Mumbai monsoon seasons, the barometric pressure changes rather rapidly, due to which the gas system fails to maintain the set differential pressure between the ambience and the RPC gas volume. As the safety bubblers on the RPC gas input lines are set to work on fixed pressure differentials, the ambient pressure changes lead to either venting out and thus wasting gas through safety bubblers or over pressuring the RPCs gas volume and thus degrading its performance. The above problem also leads to gas mixture contamination through minute leaks in gas gap. The problem stated above was solved by including the ambient barometric pressure as an input parameter in the closed loop. Using this, it is now possible to maintain any set differential pressure between the ambience and RPC gas volumes between 0 to 20mm of water column, thus always ensuring a positive pressure inside the RPC gas volume with respect to the ambience. This has resulted in improved performance of the gas system by maintaining the constant gas flow and reducing the gas toping up frequency. In this paper, we will highlight the design features and improvements of the closed loop gas system. We will present some of the performance studies and considerations for scaling up the system to be used with the engineering module and then followed by Iron Calorimeter detector (ICAL), which is designed to deploy about 30,000 RPCs of 1.8meters × 1.9 meters in area.
Noise data from tests of a 1.83 meter (6-ft-) diameter variable-pitch 1.2-pressure-ratio fan (QF-9)
NASA Technical Reports Server (NTRS)
Glaser, F. W.; Wazyniak, J. A.; Friedman, R.
1975-01-01
Acoustic and aerodynamic data for a 1.83-meter (6-ft.) diameter fan suitable for a quiet engine for short-takeoff-and-landing (STOL) aircraft are documented. The QF-9 rotor blades had an adjustable pitch feature which provided a means for testing at several rotor blade setting angles, including one for reverse thrust. The fan stage incorporated features for low noise. Far-field noise around the fan was measured without acoustic suppression over a range of operating conditions for six different rotor blade setting angles in the forward thrust configuration, and for one in the reverse configuration. Complete results of one-third-octave band analysis of the data are presented in tabular form. Also included are power spectra, data referred to the source, and sideline perceived noise levels.
An Inventory of Impact Craters on the Martian South Polar Layered Deposits
NASA Technical Reports Server (NTRS)
Plaut, J. J.
2005-01-01
The polar layered deposits (PLD) of Mars continue to be a focus of study due to the possibility that these finely layered, volatile-rich deposits hold a record of recent eras in Martian climate history. Recently, the visible sensor on 2001 Mars Odyssey s Thermal Emission Imaging System (THEMIS) has acquired 36 meter/pixel contiguous single-band visible image data sets of both the north and the south polar layered deposits, during the local spring and summer seasons. In addition, significant coverage has been obtained at the THEMIS visible sensor s full resolution of 18 meters/pixel. This paper reports on the use of these data sets to further characterize the population of impact craters on the south polar layered deposits (SPLD), and the implications of the observed population for the age and evolution of the SPLD.
MULTIPLE INPUT BINARY ADDER EMPLOYING MAGNETIC DRUM DIGITAL COMPUTING APPARATUS
Cooke-Yarborough, E.H.
1960-12-01
A digital computing apparatus is described for adding a plurality of multi-digit binary numbers. The apparatus comprises a rotating magnetic drum, a recording head, first and second reading heads disposed adjacent to the first and second recording tracks, and a series of timing signals recorded on the first track. A series of N groups of digit-representing signals is delivered to the recording head at time intervals corresponding to the timing signals, each group consisting of digits of the same significance in the numbers, and the signal series is recorded on the second track of the drum in synchronism with the timing signals on the first track. The multistage registers are stepped cyclically through all positions, and each of the multistage registers is coupled to the control lead of a separate gate circuit to open the corresponding gate at only one selected position in each cycle. One of the gates has its input coupled to the bistable element to receive the sum digit, and the output lead of this gate is coupled to the recording device. The inputs of the other gates receive the digits to be added from the second reading head, and the outputs of these gates are coupled to the adding register. A phase-setting pulse source is connected to each of the multistage registers individually to step the multistage registers to different initial positions in the cycle, and the phase-setting pulse source is actuated each N time interval to shift a sum digit to the bistable element, where the multistage register coupled to bistable element is operated by the phase- setting pulse source to that position in its cycle N steps before opening the first gate, so that this gate opens in synchronism with each of the shifts to pass the sum digits to the recording head.
NASA Astrophysics Data System (ADS)
Franzetti, M.; Garlan, T.; Le Roy, P.; Delacourt, C.; Cancouët, R.; Graindorge, D.; Deschamps, A.
2011-12-01
Marine sand dunes and sandbanks are mainly observed in continental tidal shelves (North Sea, South China Sea, North Atlantic America) and may be highly dynamic (for example up to 75 m/y in the Marsdiep inlet). So they may pose a potential risk to offshore installations and shipping. Multitemporal mapping of sandwaves, necessary to mitigate this hazard, is complicated by their dynamic character, which is still poorly understood especially in the offshore domain. In consequence, these structures are often defined as moribund at depths greater than 30 meters. The aim of this investigation is to study evolution of deeper (110 meters) complex set of sand bedforms : "Banc du Four" located in the Iroise Sea. The study area is exposed to strong tidal currents and storm waves at the junction of the Northeast Atlantic Ocean and the Western English Channel, conditions favorable to sediment dynamics. The bathymetric data, which form the basis of this study, are two Digital Terrain Modeling's (DTM's) derived from MultiBeam Echosounder (MBES) surveys : "Pourquoi-Pas?" oceanographic research vessel (R/V) in February 2009 (5 meters resolution DTM) and R/V "Albert Lucas" in August 2010 (2 meters resolution DTM). Sandwave parameters (water depth, shape, wavelength, height, symmetry index, ...) have been derived from the 2009 bathymetric data. The Banc du Four is characterized by a large sandbank (45 meters height and 2 km width) flanked by dune fields. The morphological characteristics of the dunes vary greatly (range 30 to 110 meters depth, 40 meters maximal height, 600 meters maximal width, symmetrical to asymmetrical, ...). However, this complexity can be explained by the involved sandwave dynamic (range 0 to 30 meters per year migration velocity). Spatial correlation method, applied on the two DTM's, are used to measure the migration rate. The high migration rates for deeper giant dunes bring to light the dynamic sandwave existence at depths exceeding 30-40 meters, contrary to previously accepted models. Dune asymmetry is proportional to migration rates and the lee side is always oriented towards the direction of movement. These relationships confirm the observations reported in the literature for shallower structures.
A comparison and evaluation of satellite derived positions of tracking stations
NASA Technical Reports Server (NTRS)
Vincent, S. F.; Strange, W. E.; Marsh, J. G.
1971-01-01
A comparison is presented of sets of satellite tracking station coordinate values published in the past few years by a number of investigators, i.e. Goddard Space Flight Center, Smithsonian Astrophysical Observatory, Ohio State University, The Naval Weapons Laboratory, Air Force Cambridge Research Laboratories, and Wallops Island. The comparisons have been made in terms of latitude, longitude and height. The results of the various solutions have been compared directly and also with external standards such as local survey data and gravimetrically derived geoid heights. After taking into account systematic rotations, latitude and longitude agreement on a global basis is generally 15 meters or better, on the North American Datum agreement is generally better than 10 meters. Allowing for scale differences (of the order of 2 ppm) radial agreement is generally of the order of 10 meters.
Field calibration of orifice meters for natural gas flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ting, V.C.; Shen, J.J.S.
1989-03-01
This paper presents the orifice calibration results for nominal 15.24, 10.16, and 5.08-cm (6,4,2-in.) orifice meters conducted at the Chevron's Sand Hills natural gas flow measurement facility in Crane, Texas. Over 200 test runs were collected in a field environment to study the accuracy of the orifice meters. Data were obtained at beta ratios ranging from 0.12 to 0.74 at the nominal conditions of 4576 kPa and 27{sup 0}C (650 psig and 80{sup 0}F) with a 0.57 specific gravity processed, pipeline quality natural gas. A bank of critical flow nozzles was used as the flow rate proving device to calibratemore » the orifice meters. Orifice discharge coefficients were computed with ANSI/API 2530-1985 (AGA3) and ISO 5167/ASME MFC-3M-1984 equations for every set of data points. With the orifice bore Reynolds numbers ranging from 1 to 9 million, the Sand Hills calibration data bridge the gap between the Ohio State water data at low Reynolds numbers and Chevron's high Reynolds number test data taken at a large test facility in Venice, Louisiana. The test results also successfully demonstrate that orifice meters can be accurately proved with critical flow nozzles under realistic field conditions.« less
Field Evaluation of Seepage Meters in the Coastal Marine Environment
NASA Astrophysics Data System (ADS)
Cable, J. E.; Burnett, W. C.; Chanton, J. P.; Corbett, D. R.; Cable, P. H.
1997-09-01
The response of seepage meters was evaluated in a nearshore marine environment where water motion effects are more pronounced than in lake settings, where these meters have been used traditionally. Temporal and spatial variations of seepage, as well as potential artifacts, were evaluated using empty and 1000-ml pre-filled bag measurements. Time-series measurements confirmed earlier observations that anomalously high fluxes occur during the early stages (≤10 min) of collection. As deployment times increased (30-60 min), measured flow rates stabilized at a level thought to represent the actual seepage flux. Pre-filling the plastic measurement bags effectively alleviated this anomalous, short-term influx. Reliable seepage measurements required deployment times sufficient to allow a net volume of at least 150 ml into the collection bag. Control experiments, designed by placing seepage meters inside sand-filled plastic swimming pools, served as indicators of external effects on these measurements, i.e. they served as seepage meter blanks. When winds were under 15 knots, little evidence was found that water motion caused artifacts in the seepage measurements. Tidal cycle influences on seepage rates were negligible in the present study area, but long-term temporal variations (weeks to months) proved substantial. Observed long-term changes in groundwater flux into the Gulf of Mexico correlated with water table elevation at a nearby monitoring well.
Advanced optical smoke meters for jet engine exhaust measurement
NASA Technical Reports Server (NTRS)
Pitz, R. W.
1986-01-01
Smoke meters with increased sensitivity, improved accuracy, and rapid response are needed to measure the smoke levels emitted by modern jet engines. The standard soiled tape meter in current use is based on filtering, which yields long term averages and is insensitive to low smoke levels. Two new optical smoke meter techniques that promise to overcome these difficulties have been experimentally evaluated: modulated transmission (MODTRAN) and photothermal deflection spectroscopy (PDS). Both techniques are based on light absorption by smoke, which is closely related to smoke density. They are variations on direct transmission measurements which produce a modulated signal that can be easily measured with phase sensitive detection. The MODTRAN and PDS techniques were tested on low levels of smoke and diluted samples of NO2 in nitrogen, simulating light adsorption due to smoke. The results are evaluated against a set of ideal smoke meter criteria that include a desired smoke measurement range of 0.1 to 12 mg cu.m. (smoke numbers of 1 to 50) and a frequency response of 1 per second. The MODTRAN instrument is found to be inaccurate for smoke levels below 3 mg/cu.m. and is able to make a only about once every 20 seconds because of its large sample cell. The PDS instrument meets nearly all the characteristics of an ideal smoke meter: it has excellent sensitivity over a range of smoke levels from 0.1 to 20 mg/cu.m. (smoke numbers of 1 to 60) and good frequency response (1 per second).
NASA Astrophysics Data System (ADS)
Gryning, S. E.; Batchvarova, E.; Pena, A.; Mikkelsen, T.; Brümmer, B.; Emeis, S.; Gulstad, L.; Lee, N.
2010-09-01
Predicting the wind at typical heights of present and future wind turbines is a considerable scientific challenge. Presently applied models are accurate within the surface layer. New measurements and instrument synergies are necessary as basis for developing new wind models and understanding the physical processes that form the wind profile in order to describe the wind profile above it. Analysis of the wind and turbulence profiles from a meteorological mast at heights up to 160 meters and wind lidars up to 300 meters at the National test station at Høvsøre, Denmark, shows deviations of the wind profile above 80 meters the from the profile used so far near the surface. It also reveals the importance of the boundary-layer height as a physical parameter for the description of the wind profile. In the Tall Wind project, mast and lidar measurements of wind and fluxes will be combined with monitoring of the boundary-layer height by use of an aerosol lidar. At the main project monitoring sites (Høvsøre in Denmark and Hamburg in Germany) long term monitoring programmes on tall masts (160 and 300 meters) already exists and will be intensified. As part of the project the wind profile will be measured up to 1000 meters by a wind lidar (windcube) and the boundary-layer height by an aerosol lidar. The new data sets can be used for theoretical developments and evaluation of meso-scale meteorological models. The project is an international collaboration between academia (Risoe-DTU, HU and KIT) and industry (Vestas and DONG), funded by the Danish Research Agency, the Strategic Research Council (Sagsnr. 2104-08-0025). In the paper the set-up of the Tall Wind project will be described and some first results and experience will be presented.
Methods for accurate estimation of net discharge in a tidal channel
Simpson, M.R.; Bland, R.
2000-01-01
Accurate estimates of net residual discharge in tidally affected rivers and estuaries are possible because of recently developed ultrasonic discharge measurement techniques. Previous discharge estimates using conventional mechanical current meters and methods based on stage/discharge relations or water slope measurements often yielded errors that were as great as or greater than the computed residual discharge. Ultrasonic measurement methods consist of: 1) the use of ultrasonic instruments for the measurement of a representative 'index' velocity used for in situ estimation of mean water velocity and 2) the use of the acoustic Doppler current discharge measurement system to calibrate the index velocity measurement data. Methods used to calibrate (rate) the index velocity to the channel velocity measured using the Acoustic Doppler Current Profiler are the most critical factors affecting the accuracy of net discharge estimation. The index velocity first must be related to mean channel velocity and then used to calculate instantaneous channel discharge. Finally, discharge is low-pass filtered to remove the effects of the tides. An ultrasonic velocity meter discharge-measurement site in a tidally affected region of the Sacramento-San Joaquin Rivers was used to study the accuracy of the index velocity calibration procedure. Calibration data consisting of ultrasonic velocity meter index velocity and concurrent acoustic Doppler discharge measurement data were collected during three time periods. Two sets of data were collected during a spring tide (monthly maximum tidal current) and one of data collected during a neap tide (monthly minimum tidal current). The relative magnitude of instrumental errors, acoustic Doppler discharge measurement errors, and calibration errors were evaluated. Calibration error was found to be the most significant source of error in estimating net discharge. Using a comprehensive calibration method, net discharge estimates developed from the three sets of calibration data differed by less than an average of 4 cubic meters per second, or less than 0.5% of a typical peak tidal discharge rate of 750 cubic meters per second.
NASA Astrophysics Data System (ADS)
Jaroszkiewicz, George
2017-12-01
Preface; Acronyms; 1. Introduction; 2. Questions and answers; 3. Classical bits; 4. Quantum bits; 5. Classical and quantum registers; 6. Classical register mechanics; 7. Quantum register dynamics; 8. Partial observations; 9. Mixed states and POVMs; 10. Double-slit experiments; 11. Modules; 12. Computerization and computer algebra; 13. Interferometers; 14. Quantum eraser experiments; 15. Particle decays; 16. Non-locality; 17. Bell inequalities; 18. Change and persistence; 19. Temporal correlations; 20. The Franson experiment; 21. Self-intervening networks; 22. Separability and entanglement; 23. Causal sets; 24. Oscillators; 25. Dynamical theory of observation; 26. Conclusions; Appendix; Index.
Alternative Practice Dental Hygiene in California: Past, Present, and Future
MERTZ, ELIZABETH; GLASSMAN, PAUL
2012-01-01
This study examines the development of the registered dental hygienist in alternative practice in California through an analysis of archival documents, stakeholder interviews, and two surveys of the registered dental hygienist in alternative practice. Designing, testing and implementing a new practice model for dental hygienists took 23 years. Today, registered dental hygienists in alternative practice have developed viable alternative methods for delivering preventive oral health care services in a range of settings with patients who often have no other source of access to care. PMID:21337961
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
...'s statements of account shall set forth each step of its calculations with sufficient information to... available by persons making digital phonorecord deliveries.'' Register's Division of Authority Decision... type of information in a notice of use (but not in the statement of account) to be served on the...
ERIC Educational Resources Information Center
McElveen, Peggy C.
Supporting performance objective 28 of the V-TECS (Vocational-Technical Education Consortium of States) Secretarial Catalog, both a set of student materials and an instructor's manual on preparing a payroll register, employee earnings' records, and paychecks are included in this packet, which is one in a series. The student materials include a…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-26
... Control Number: 2120-0042. Title: Aircraft Registration. Form Numbers: FAA Forms 8050-1, 8050-2, 8050-4... states that all aircraft must be registered before they may be flown. It sets forth registration... of registration. The information collected is used by the FAA to register an aircraft or hold an...
Murray-Parahi, Pauline; DiGiacomo, Michelle; Jackson, Debra; Davidson, Patricia M
2016-11-01
To summarise the literature describing new graduate nurse transition to professional practice within the primary health care (PHC) setting. There is a plethora of research literature spanning several decades about new graduate nurse transition in the acute care setting. Yet, the experiences of new graduate nurse in the PHC setting is unremarkable particularly considering the increasing demand for skilled health care workers and focus of health reform to provide care where people work and live. Electronic data bases, Academic Search Complete, EBSCO, Medline, PsycINFO, CINHAL, and ERIC were searched using a combination of terms and synonyms arising from three key concepts which identify the phenomenon; 'transition', 'new graduate registered nurse' and 'primary health care. An inclusive search strategy placed no limits on language or publication date. Of the 50 articles located and examined for relevance; 40 were sourced through databases and 10 from Google Scholar/Alerts and hand-searching references. None of the 19 articles retained for analysis addressed all key concepts. Some challenges of researching the professional transition of graduate nurses in PHC settings included, an absence of definitive transition models, a dearth of literature and deference to acute care research. Nursing in PHC settings, particularly the client's home is notably different to hospital settings because of higher levels of isolation and autonomy. Societal changes, health reform and subsequent demand for skilled workers in PHC settings has caused health care providers to question the logic that such roles are only for experienced nurses. Implications arise for education and health service providers who desire to close the theory practice gap and mitigate risk for all stakeholders when next generation nurses have limited opportunities to experience PHC roles as undergraduates and newly graduated registered nurses are already transitioning in this setting. © 2016 John Wiley & Sons Ltd.
Equivalent Noise Dose Obtained through Hearing Aids in the Classrooms of Hearing-Impaired Children.
ERIC Educational Resources Information Center
Wilde, Ronald A.
1990-01-01
A commercial noise dose meter was used to estimate the equivalent noise dose received through high-gain hearing aids worn in four classrooms in a school for deaf children. There were no significant differences among nominal saturation sound pressure level (SSPL) settings, and all SSPL settings produced very high equivalent noise doses. (Author/JDD)
Make Your Own Transpiring Tree
ERIC Educational Resources Information Center
Martinez Vilalta, Jordi; Sauret, Miquel; Duro, Alicia; Pinol, Josep
2003-01-01
In this paper we present a simple set-up that illustrates the mechanism of sap ascent in plants and demonstrates that it can easily draw water up to heights of a few meters. The set-up consists of a tube with the lower end submerged in water and the upper one connected to a filter supported by a standard filter-holder. The evaporation of water…
Hageman, David; Fokkenrood, Hugo Jp; Gommans, Lindy Nm; van den Houten, Marijn Ml; Teijink, Joep Aw
2018-04-06
Although supervised exercise therapy (SET) provides significant symptomatic benefit for patients with intermittent claudication (IC), it remains an underutilized tool. Widespread implementation of SET is restricted by lack of facilities and funding. Structured home-based exercise therapy (HBET) with an observation component (e.g., exercise logbooks, pedometers) and just walking advice (WA) are alternatives to SET. This is the second update of a review first published in 2006. The primary objective was to provide an accurate overview of studies evaluating effects of SET programs, HBET programs, and WA on maximal treadmill walking distance or time (MWD/T) for patients with IC. Secondary objectives were to evaluate effects of SET, HBET, and WA on pain-free treadmill walking distance or time (PFWD/T), quality of life, and self-reported functional impairment. The Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register (December 16, 2016) and the Cochrane Central Register of Controlled Trials (2016, Issue 11). We searched the reference lists of relevant studies identified through searches for other potential trials. We applied no restriction on language of publication. We included parallel-group randomized controlled trials comparing SET programs with HBET programs and WA in participants with IC. We excluded studies in which control groups did not receive exercise or walking advice (maintained normal physical activity). We also excluded studies comparing exercise with percutaneous transluminal angioplasty, bypass surgery, or drug therapy. Three review authors (DH, HF, and LG) independently selected trials, extracted data, and assessed trials for risk of bias. Two other review authors (MvdH and JT) confirmed the suitability and methodological quality of trials. For all continuous outcomes, we extracted the number of participants, mean outcome, and standard deviation for each treatment group through the follow-up period, if available. We extracted Medical Outcomes Study Short Form 36 outcomes to assess quality of life, and Walking Impairment Questionnaire outcomes to assess self-reported functional impairment. As investigators used different scales to present results of walking distance and time, we standardized reported data to effect sizes to enable calculation of an overall standardized mean difference (SMD). We obtained summary estimates for all outcome measures using a random-effects model. We assessed the quality of evidence using the GRADE approach. For this update, we included seven additional studies, making a total of 21 included studies, which involved a total of 1400 participants: 635 received SET, 320 received HBET, and 445 received WA. In general, SET and HBET programs consisted of three exercise sessions per week. Follow-up ranged from six weeks to two years. Most trials used a treadmill walking test to investigate effects of exercise therapy on walking capacity. However, two trials assessed only quality of life, functional impairment, and/or walking behavior (i.e., daily steps measured by pedometer). The overall methodological quality of included trials was moderate to good. However, some trials were small with respect to numbers of participants, ranging from 20 to 304.SET groups showed clear improvement in MWD/T compared with HBET and WA groups, with overall SMDs at three months of 0.37 (95% confidence interval [CI] 0.12 to 0.62; P = 0.004; moderate-quality evidence) and 0.80 (95% CI 0.53 to 1.07; P < 0.00001; high-quality evidence), respectively. This translates to differences in increased MWD of approximately 120 and 210 meters in favor of SET groups. Data show improvements for up to six and 12 months, respectively. The HBET group did not show improvement in MWD/T compared with the WA group (SMD 0.30, 95% CI -0.45 to 1.05; P = 0.43; moderate-quality evidence).Compared with HBET, SET was more beneficial for PFWD/T but had no effect on quality of life parameters nor on self-reported functional impairment. Compared with WA, SET was more beneficial for PFWD/T and self-reported functional impairment, as well as for some quality of life parameters (e.g., physical functioning, pain, and physical component summary after 12 months), and HBET had no effect.Data show no obvious effects on mortality rates. Thirteen of the 1400 participants died, but no deaths were related to exercise therapy. Overall, adherence to SET was approximately 80%, which was similar to that reported with HBET. Only limited adherence data were available for WA groups. Evidence of moderate and high quality shows that SET provides an important benefit for treadmill-measured walking distance (MWD and PFWD) compared with HBET and WA, respectively. Although its clinical relevance has not been definitively demonstrated, this benefit translates to increased MWD of 120 and 210 meters after three months in SET groups. These increased walking distances are likely to have a positive impact on the lives of patients with IC. Data provide no clear evidence of a difference between HBET and WA. Trials show no clear differences in quality of life parameters nor in self-reported functional impairment between SET and HBET. However, evidence is of low and very low quality, respectively. Investigators detected some improvements in quality of life favoring SET over WA, but analyses were limited by small numbers of studies and participants. Future studies should focus on disease-specific quality of life and other functional outcomes, such as walking behavior and physical activity, as well as on long-term follow-up.
NASA Astrophysics Data System (ADS)
Bailey, T. L.; Sutherland-Montoya, D.
2015-12-01
High resolution topographic analysis methods have become important tools in geomorphology. Structure from Motion photogrammetry offers a compelling vehicle for geomorphic change detection in fluvial environments. This process can produce arbitrarily high resolution, geographically registered spectral and topographic coverages from a collection of overlapping digital imagery from consumer cameras. Cuneo Creek has had three historically observed episodes of rapid aggradation (1955, 1964, and 1997). The debris flow deposits continue to be major sources of sediment sixty years after the initial slope failure. Previous studies have monitored the sediment storage volume and particle size since 1976 (in 1976, 1982, 1983, 1985, 1986, 1987, 1998, 2003). We reoccupied 3 previously surveyed stream cross sections on Sept 30, 2014 and March 30, 2015, and produced photogrammetric point clouds using a pole mounted camera with a remote view finder to take nadir view images from 4.3 meters above the channel bed. Ground control points were registered using survey grade GPS and typical cross sections used over 100 images to build the structure model. This process simultaneously collects channel geometry and we used it to also generate surface texture metrics, and produced DEMs with point cloud densities above 5000 points / m2. In the period between the surveys, a five year recurrence interval discharge of 20 m3/s scoured the channel. Surface particle size distribution has been determined for each observation period using image segmentation algorithms based on spectral distance and compactness. Topographic differencing between the point clouds shows substantial channel bed mobilization and reorganization. The net decline in sediment storage is in excess of 4 x 10^5 cubic meters since the 1964 aggradation peak, with associated coarsening of surface particle sizes. These new methods provide a promising rapid assessment tool for measurement of channel responses to sediment inputs.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-25
.... 080225267-91393-03] RIN 0648-XA370 Western Pacific Pelagic Fisheries; Closure of the Hawaii Shallow- Set...: Temporary rule; fishery closure. SUMMARY: NMFS closes the shallow-set pelagic longline fishery north of the Equator for all vessels registered under the Hawaii longline limited access program. The shallow-set...
Pilcher, Janine; Holliday, Mark; Ebmeier, Stefan; McKinstry, Steve; Messaoudi, Fatiha; Weatherall, Mark; Beasley, Richard
2016-01-01
The SmartTouch Ventolin monitor (Adherium, Auckland, New Zealand) is an electronic monitor for use with a Ventolin metered dose inhaler, which records the date and time of inhaler actuations. This technology has the potential to allow in-depth analysis of patterns of inhaler use in clinical trial settings. The aim of this study was to determine the accuracy of the SmartTouch Ventolin monitor in recording Ventolin actuations. 20 SmartTouch Ventolin monitors were attached to Ventolin metered dose inhalers. Bench testing was performed over a 10-week period, to reflect the potential time frame between visits in a clinical trial. Inhaler actuations were recorded in a paper diary, which was compared with data uploaded from the monitors. 2560 actuations were performed during the 10-week study period. Monitor sensitivity for diary-recorded actuations was 99.9% with a lower 97.5% confidence bound of 99.7%. The positive predictive value for diary-recorded actuations was 100% with a 97.5% lower confidence bound of 99.9%. The SmartTouch Ventolin monitor is highly accurate in recording and retaining electronic data. It can be recommended for use in clinical trial settings in which training and quality control systems are incorporated into study protocols to ensure accurate data acquisition.
Pilcher, Janine; Holliday, Mark; Ebmeier, Stefan; McKinstry, Steve; Messaoudi, Fatiha; Weatherall, Mark; Beasley, Richard
2016-01-01
Background The SmartTouch Ventolin monitor (Adherium, Auckland, New Zealand) is an electronic monitor for use with a Ventolin metered dose inhaler, which records the date and time of inhaler actuations. This technology has the potential to allow in-depth analysis of patterns of inhaler use in clinical trial settings. The aim of this study was to determine the accuracy of the SmartTouch Ventolin monitor in recording Ventolin actuations. Methods 20 SmartTouch Ventolin monitors were attached to Ventolin metered dose inhalers. Bench testing was performed over a 10-week period, to reflect the potential time frame between visits in a clinical trial. Inhaler actuations were recorded in a paper diary, which was compared with data uploaded from the monitors. Results 2560 actuations were performed during the 10-week study period. Monitor sensitivity for diary-recorded actuations was 99.9% with a lower 97.5% confidence bound of 99.7%. The positive predictive value for diary-recorded actuations was 100% with a 97.5% lower confidence bound of 99.9%. Conclusions The SmartTouch Ventolin monitor is highly accurate in recording and retaining electronic data. It can be recommended for use in clinical trial settings in which training and quality control systems are incorporated into study protocols to ensure accurate data acquisition. PMID:27026805
POSE Algorithms for Automated Docking
NASA Technical Reports Server (NTRS)
Heaton, Andrew F.; Howard, Richard T.
2011-01-01
POSE (relative position and attitude) can be computed in many different ways. Given a sensor that measures bearing to a finite number of spots corresponding to known features (such as a target) of a spacecraft, a number of different algorithms can be used to compute the POSE. NASA has sponsored the development of a flash LIDAR proximity sensor called the Vision Navigation Sensor (VNS) for use by the Orion capsule in future docking missions. This sensor generates data that can be used by a variety of algorithms to compute POSE solutions inside of 15 meters, including at the critical docking range of approximately 1-2 meters. Previously NASA participated in a DARPA program called Orbital Express that achieved the first automated docking for the American space program. During this mission a large set of high quality mated sensor data was obtained at what is essentially the docking distance. This data set is perhaps the most accurate truth data in existence for docking proximity sensors in orbit. In this paper, the flight data from Orbital Express is used to test POSE algorithms at 1.22 meters range. Two different POSE algorithms are tested for two different Fields-of-View (FOVs) and two different pixel noise levels. The results of the analysis are used to predict future performance of the POSE algorithms with VNS data.
Setting standards for the future
DOT National Transportation Integrated Search
1993-12-01
Traffic management systems, such as metering lights, ramp signals and stop signs and lights, have been in use for so many years that drivers now take them for granted. The planned introduction of Advanced Traffic Management Systems (ATMS) will ...
Chiovitti, Rosalina F
2008-02-01
The concept of caring is described as intangible, abstract, and invisible in nursing practice. This has translated into a view of caring as a personal choice or natural obligation rather than a deliberate process. While there has been movement to delineate caring within nursing in general, the psychiatric nurse's perspective on caring has been absent from theoretical works and measures constructed to describe nurse's work. To develop a substantive grounded theory of caring from the perspective of Registered Nurses working with patients in three Canadian acute psychiatric hospital settings. The qualitative research design of grounded theory methodology was used to develop a theory of caring. Three urban, acute psychiatric hospital settings in Canada. Two were general hospitals and one was a psychiatric hospital. Registered Nurses (N=17) licensed with the College of Nurses of Ontario. In-depth interviews with Registered Nurses were conducted using theoretical sampling. The data were analysed using constant comparative analysis. Protective empowering is the basic social psychological process that represents Registered Nurses' caring with patients in acute psychiatric hospital settings. Nurses accomplish protective empowering through six main categories of: (1) respecting the patient; (2) not taking the patient's behaviour personally; (3) keeping the patient safe; (4) encouraging the patient's health; (5) authentic relating; and (6) interactive teaching. The six main categories were accomplished through 27 subcategories. In the theory of protective empowering, the goal is to help patients participate in activities contributing to convalescence, health, and/or quality of life. The theory of protective empowering provides six main categories and 27 subcategories that can be transferred to funding formulas, patient health record documentation systems, nurse orientation and education programs, nurse role descriptions, and used in guiding discussions about organizational values of patient-centred care within a collaborative multidisciplinary context.
NASA Technical Reports Server (NTRS)
Sanchez, Braulio V.; Nishihama, Masahiro
1997-01-01
Half-daily global wind speeds in the east-west (u) and north-south (v) directions at the 10-meter height level were obtained from the European Centre for Medium Range Weather Forecasts (ECMWF) data set of global analyses. The data set covered the period 1985 January to 1995 January. A spherical harmonic expansion to degree and order 50 was used to perform harmonic analysis of the east-west (u) and north-south (v) velocity field components. The resulting wind field is displayed, as well as the residual of the fit, at a particular time. The contribution of particular coefficients is shown. The time variability of the coefficients up to degree and order 3 is presented. Corresponding power spectrum plots are given. Time series analyses were applied also to the power associated with degrees 0-10; the results are included.
NASA Technical Reports Server (NTRS)
Oberholtzer, David; Donelan, Mark
1996-01-01
This is a guide to the data that was collected during the Surface Wave Dynamics Experiment (SWADE) carried out from October 1990 through March 1991. The area studied was the Mid-Atlantic bight. Buoys collected data continuously during this time. Included are three 3-meter discus buoys the National Data Buoy Center (NDBC) set in the area for this project, they then later added a fourth 3-meter discus and an experimental coastal buoy. Data from all of the NDBC buoys and stations from New England to Florida have been included in the data set; in addition, several other buoys monitored meteorological and ocean conditions for parts of the experiment. Several times during the project, there were intensive data collection periods. During the third of these, there were 7 aircraft and a ship collecting data. Maps of each mission from the platforms that have shared their data are included. The anonymous FTP site that has been established to make this data public is described.
Gas flow meter and method for measuring gas flow rate
Robertson, Eric P.
2006-08-01
A gas flow rate meter includes an upstream line and two chambers having substantially equal, fixed volumes. An adjustable valve may direct the gas flow through the upstream line to either of the two chambers. A pressure monitoring device may be configured to prompt valve adjustments, directing the gas flow to an alternate chamber each time a pre-set pressure in the upstream line is reached. A method of measuring the gas flow rate measures the time required for the pressure in the upstream line to reach the pre-set pressure. The volume of the chamber and upstream line are known and fixed, thus the time required for the increase in pressure may be used to determine the flow rate of the gas. Another method of measuring the gas flow rate uses two pressure measurements of a fixed volume, taken at different times, to determine the flow rate of the gas.
Method and system for providing autonomous control of a platform
NASA Technical Reports Server (NTRS)
Seelinger, Michael J. (Inventor); Yoder, John-David (Inventor)
2012-01-01
The present application provides a system for enabling instrument placement from distances on the order of five meters, for example, and increases accuracy of the instrument placement relative to visually-specified targets. The system provides precision control of a mobile base of a rover and onboard manipulators (e.g., robotic arms) relative to a visually-specified target using one or more sets of cameras. The system automatically compensates for wheel slippage and kinematic inaccuracy ensuring accurate placement (on the order of 2 mm, for example) of the instrument relative to the target. The system provides the ability for autonomous instrument placement by controlling both the base of the rover and the onboard manipulator using a single set of cameras. To extend the distance from which the placement can be completed to nearly five meters, target information may be transferred from navigation cameras (used for long-range) to front hazard cameras (used for positioning the manipulator).
SPRUCE Bog Surface Elevation Assessments with SET Instrument Beginning in 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, Paul J; Phillips, Jana R; Brice, Deanne J
This data set reports plot-specific bog surface elevation measurements collected with the SPRUCE Elevation Transect (SET) instrument. Measurements are reported as absolute elevation in meters above mean sea level for two locations in each of the SPRUCE experimental treatment plots and additional ambient boardwalk plots -- 4, 5, 6, 7, 8, 9, 10, 11, 13, 14, 15, 16, 17, 19, 20 and 21. This data set reports measurements collected from June 2013 through August 2017, but it will be appended annually as new data are collected.
Photogrammetric Data Set, 1957-2000, and Bathymetric Measurements for Columbia Glacier, Alaska
Krimmel, Robert M.
2001-01-01
Major changes in the length, speed, surface altitude, and calving rate of Columbia Glacier, Alaska have been recorded with stereo vertical photography acquired on 119 dates from 1957 to 2000. Photogrammetric analysis of this photographic record has resulted in precise measurement of these changes. From 1982 to 2000 Columbia Glacier retreated 12 kilometers, reduced its thickness by as much as 400 meters, increased its speed from about 5 to 30 meters per day, and increased its calving rate from 3 to 18 million cubic meters per day. All photogrammetric data for Columbia Glacier from 1957 to 2000 are included in this report, as well as supplemental data of ice-dammed lake surface levels, stagnant ice ablation rate, forebay bathymetry, ground control, and camera calibrations. These data are contained in 481 files, all preserved on a CD-ROM included with this report.
Radial dependence of HF wave field strength in the BPD column. [Beam Plasma Discharge
NASA Technical Reports Server (NTRS)
Jost, R. J.; Anderson, H. R.; Bernstein, W.; Kellogg, P. J.
1982-01-01
The results of a recent set of RF frequency measurements of the beam plasma discharge (BPD) performed in order to determine a quantitative value for the field strength in the plasma frequency region of the spectrum are presented. The parallel and perpendicular components of the plasma wave electric fields inside the BPD column have comparable field strengths, on the order of 10 volts/m. The radial dependence of the field strength is very strong, decreasing by as much as 40 dB within one meter from the beam center, with the illumination or discharge column approximately one meter in diameter. The field strength inside the column increases as a function of distance along the beam at least for several meters from the gun aperture. The frequency and amplitude of the plasma wave increases with beam current. A particularly rapid increase in these parameters occurs as the beam current approaches the critical current.
NASA Technical Reports Server (NTRS)
Hendry, David F. (Inventor)
1993-01-01
In a data system having a memory, plural input/output (I/O) devices and a bus connecting each of the I/O devices to the memory, a direct memory access (DMA) controller regulating access of each of the I/O devices to the bus, including a priority register storing priorities of bus access requests from the I/O devices, an interrupt register storing bus access requests of the I/O devices, a resolver for selecting one of the I/O devices to have access to the bus, a pointer register storing addresses of locations in the memory for communication with the one I/O device via the bus, a sequence register storing an address of a location in the memory containing a channel program instruction which is to be executed next, an ALU for incrementing and decrementing addresses stored in the pointer register, computing the next address to be stored in the sequence register, computing an initial contents of each of the register. The memory contains a sequence of channel program instructions defining a set up operation wherein the contents of each of the registers in the channel register is initialized in accordance with the initial contents computed by the ALU and an access operation wherein data is transferred on the bus between a location in the memory whose address is currently stored in the pointer register and the one I/O device enabled by the resolver.
ERIC Educational Resources Information Center
Jalongo, Mary Renck; Astorino, Terri; Bomboy, Nancy
2004-01-01
Trained therapy dogs are becoming an increasingly common sight in many educational and health care settings. This article, coauthored by a college professor, a Therapy Dogs International, Inc., Evaluator and local program director, and a registered nurse reviews the research on using registered therapy dogs as adjuncts in school programs and…
Stanton, Gregory P.; Kress, Wade; Hobza, Christopher M.; Czarnecki, John B.
2003-01-01
A surface-geophysical investigation of the Red River Aluminum site at Stamps, Arkansas, was conducted in cooperation with the Arkansas Department of Environmental Quality to determine the possible extent and depth of saltwater contamination. Water-level measurements indicate the distance to water level below land surface ranges from about 1.2 to 3.9 feet (0.37 to 1.19 meters) in shallow monitor wells and about 10.5 to 17.1 feet (3.20 to 5.21 meters) in deeper monitoring wells. The two-dimensional, direct-current resistivity method identified resistivities less than 5 ohm-meters which indicated possible areas of salt contamination occurring in near-surface or deep subsurface ground water along four resistivity lines within the site. One line located east of the site yielded data that demonstrated no effect of salt contamination. Sections from two of the five data sets were modeled. The input model grids were created on the basis of the known geology and the results and interpretations of borehole geophysical data. The clay-rich Cook Mountain Formation is modeled as 25 ohm-meters and extends from 21 meters (68.9 feet) below land surface to the bottom of the model (about 52 meters (170.6 feet)). The models were used to refine interpretation of the resistivity data and to determine extent of saltwater contamination and depth to the Cook Mountain Formation. Data from the resistivity lines indicate both near-surface and subsurface saltwater contamination. The near-surface contamination appears as low resistivity (less than 5 ohm-meters) on four of the five resistivity lines, extending up to 775 meters (2,542.8 feet) horizontally in a line that traverses the entire site south to north. Model resistivity data indicate that the total depth of saltwater contamination is about 18 meters (59 feet) below land surface. Data from four resistivity lines identified areas containing low resistivity anomalies interpreted as possible salt contamination. A fifth line located just east of the site showed no saltwater contamination.
Five meters of H(2)O: the pressure at the urinary bladder neck during human ejaculation.
Böhlen, D; Hugonnet, C L; Mills, R D; Weise, E S; Schmid, H P
2000-09-01
There are no data in the literature on pressure changes in the prostatic urethra during ejaculation. In healthy men, it has always been postulated that there must be a pressure gradient in order to prevent retrograde ejaculation, but scientific proof for that is pending. In five healthy male volunteers, the pressure profile in the prostatic urethra was registered during ejaculation, using a 10 French balloon catheter with 16 pressure channels. The channels were arranged in pairs at 5-mm intervals, beginning just below the balloon at the bladder neck and extending down to the external urethral sphincter. In the proximal part of the prostatic urethra, a pressure of up to 500 cm of H(2)O was measured in all subjects. Contrary to that, pressures did not exceed 400 cm of H(2)O distally to the verumontanum. A novel method to register the pressure profile in the lower urinary tract during ejaculation (ejaculomanometry) is presented. This study adds to the knowledge of the normal physiology of reproductive function and may be useful in the evaluation of male sexual and reproductive disorders. Copyright 2000 Wiley-Liss, Inc.
NASA Technical Reports Server (NTRS)
Grimsley, Brian W.; Sutter, James K.; Burke, Eric R.; Dixon, Genevieve D.; Gyekenyesi, Thomas G.; Smeltzer, Stanley S.
2012-01-01
Several 1/16th-scale curved sandwich composite panel sections of a 10 m diameter barrel were fabricated to demonstrate the manufacturability of large-scale curved sections using minimum gauge, [+60/-60/0]s, toughened epoxy composite facesheets co-cured with low density (50 kilograms per cubic meters) aluminum honeycomb core. One of these panels was fabricated out of autoclave (OoA) by the vacuum bag oven (VBO) process using Cycom(Registered Trademark) T40-800b/5320-1 prepreg system while another panel with the same lay-up and dimensions was fabricated using the autoclave-cure, toughened epoxy prepreg system Cycom(Registered Trademark) IM7/977-3. The resulting 2.44 m x 2 m curved panels were investigated by non-destructive evaluation (NDE) at NASA Langley Research Center (NASA LaRC) to determine initial fabrication quality and then cut into smaller coupons for elevated temperature wet (ETW) mechanical property characterization. Mechanical property characterization of the sandwich coupons was conducted including edge-wise compression (EWC), and compression-after-impact (CAI) at conditions ranging from 25 C/dry to 150 C/wet. The details and results of this characterization effort are presented in this paper.
NASA Technical Reports Server (NTRS)
Lee, Zhong-Ping; Carder, Kendall L.
2001-01-01
A multi-band analytical (MBA) algorithm is developed to retrieve absorption and backscattering coefficients for optically deep waters, which can be applied to data from past and current satellite sensors, as well as data from hyperspectral sensors. This MBA algorithm applies a remote-sensing reflectance model derived from the Radiative Transfer Equation, and values of absorption and backscattering coefficients are analytically calculated from values of remote-sensing reflectance. There are only limited empirical relationships involved in the algorithm, which implies that this MBA algorithm could be applied to a wide dynamic range of waters. Applying the algorithm to a simulated non-"Case 1" data set, which has no relation to the development of the algorithm, the percentage error for the total absorption coefficient at 440 nm a (sub 440) is approximately 12% for a range of 0.012 - 2.1 per meter (approximately 6% for a (sub 440) less than approximately 0.3 per meter), while a traditional band-ratio approach returns a percentage error of approximately 30%. Applying it to a field data set ranging from 0.025 to 2.0 per meter, the result for a (sub 440) is very close to that using a full spectrum optimization technique (9.6% difference). Compared to the optimization approach, the MBA algorithm cuts the computation time dramatically with only a small sacrifice in accuracy, making it suitable for processing large data sets such as satellite images. Significant improvements over empirical algorithms have also been achieved in retrieving the optical properties of optically deep waters.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... standard was set at 15 micrograms per cubic meter ([mu]g/m\\3\\), based on the 3-year average of annual... 2.5 standard was set at 65 [mu]g/m\\3\\, based on the 3- year average of the 98th percentile of 24... partially approve the submittal based on EPA's independent evaluation of Nevada's impact on receptor states...
Record Drive Day, Opportunity Sol 383 3-D
2005-03-05
On Feb. 19, 2005, NASA Mars Exploration Rover Opportunity set a one-day distance record for martian driving; Opportunity rolled 177.5 meters 582 feet across the plain of Meridiani. 3D glasses are necessary to view this image.
Whole-Home Dehumidifiers: Field-Monitoring Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burke, Tom; Willem, Henry; Ni, Chun Chun
2014-09-23
Lawrence Berkeley National Laboratory (LBNL) initiated a WHD field-metering study to expand current knowledge of and obtain data on WHD operation and energy consumption in real-world applications. The field study collected real-time data on WHD energy consumption, along with information regarding housing characteristics, consumer behavior, and various outdoor conditions expected to affect WHD performance and efficiency. Although the metering study collected similar data regarding air conditioner operation, this report discusses only WHDs. The primary objectives of the LBNL field-metering study are to (1) expand knowledge of the configurations, energy consumption profiles, consumer patterns of use (e.g., relative humidity [RH] settings),more » and environmental parameters of whole-home dehumidification systems; and (2) develop distributions of hours of dehumidifier operation in four operating modes: off, standby, fan-only, and compressor (also called dehumidification mode). Profiling energy consumption entails documenting the power consumption, duration of power consumption in different modes, condensate generation, and properties of output air of an installed system under field conditions of varying inlet air temperature and RH, as well as system configuration. This profiling provides a more detailed and deeper understanding of WHD operation and its complexities. This report describes LBNL’s whole-home dehumidification field-metering study conducted at four homes in Wisconsin and Florida. The initial phase of the WHD field-metering study was conducted on one home in Madison, Wisconsin, from June to December of 2013. During a second phase, three Florida homes were metered from June to October of 2014. This report presents and examines data from the Wisconsin site and from the three Florida sites.« less
Voulgaris, Gerasimos; Aleksejeva, Jelena
2017-04-24
The city of Shizuoka directly faces the Nankai Trough (known for its tsunamigenic history), and is facing a potential tsunami threat. In this setting vertical evacuation can be of great significance in reducing loss of life. We apply a GIS based method in order to identify sites that could be utilized for vertical evacuation within the existing building stock of the city, under two tsunami scenarios of 5 and 10 meters of run-up. For each building, we estimate the volume that is expected to be lost per scenario, as well as the number of people inside and how that number fluctuates over different times of the day. Using the criteria of 25% or less building volume loss and 6 cubic meters of volume per person, resulted in 2,046 potential sites for the 10 meter scenario and 1,643 potential sites for the 5 meter scenario, with the maximum amount of people that can potentially be accepted in these sites in the morning hours being 873,537 in the 10 meter scenario and 304,734 in the 5 meter scenario. Our approach has shown that there is a temporal aspect in tsunami vertical evacuation due to the movement of the local population throughout the day. the proposed method can be used for preliminary identification of potential vertical evacuation sites, however, it must be followed by further vulnerability and engineering assessments of buildings, in combination with accessibility and evacuation routing in order to reach a viable and complete evacuation plan.
Voulgaris, Gerasimos; Aleksejeva, Jelena
2017-01-01
Introduction: The city of Shizuoka directly faces the Nankai Trough (known for its tsunamigenic history), and is facing a potential tsunami threat. In this setting vertical evacuation can be of great significance in reducing loss of life. Methods: We apply a GIS based method in order to identify sites that could be utilized for vertical evacuation within the existing building stock of the city, under two tsunami scenarios of 5 and 10 meters of run-up. For each building, we estimate the volume that is expected to be lost per scenario, as well as the number of people inside and how that number fluctuates over different times of the day. Results: Using the criteria of 25% or less building volume loss and 6 cubic meters of volume per person, resulted in 2,046 potential sites for the 10 meter scenario and 1,643 potential sites for the 5 meter scenario, with the maximum amount of people that can potentially be accepted in these sites in the morning hours being 873,537 in the 10 meter scenario and 304,734 in the 5 meter scenario. Discussion: Our approach has shown that there is a temporal aspect in tsunami vertical evacuation due to the movement of the local population throughout the day. the proposed method can be used for preliminary identification of potential vertical evacuation sites, however, it must be followed by further vulnerability and engineering assessments of buildings, in combination with accessibility and evacuation routing in order to reach a viable and complete evacuation plan. PMID:28736680
Hardware support for software controlled fast reconfiguration of performance counters
Salapura, Valentina; Wisniewski, Robert W.
2013-06-18
Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.
Hardware support for software controlled fast reconfiguration of performance counters
Salapura, Valentina; Wisniewski, Robert W
2013-09-24
Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.
Developing a policy for delegation of nursing care in the school setting.
Spriggle, Melinda
2009-04-01
School nurses are in a unique position to provide care for students with special health care needs in the school setting. The incidence of chronic conditions and improved technology necessitate care of complex health care needs that had formerly been managed in inpatient settings. Delegation is a tool that may be used by registered nurses to allow unlicensed assistive personnel to perform appropriate nursing tasks and activities while keeping in mind that the registered nurse ultimately retains accountability for the delegation. The legal parameters for nursing delegation are defined by State Nurse Practice Acts, State Board of Nursing guidelines, and Nursing Administrative Rules/Regulations. Delegation becomes more challenging when carried out in a non-health care setting. School administrators may not be aware of legal issues related to delegation of nursing care in the school setting. It is crucial for school nurses to have a working knowledge of the delegation process. Development of a specific delegation policy will ensure that delegation is carried out in a manner providing for safe and appropriate care in the school setting.
Large scale Wyoming transportation data: a resource planning tool
O'Donnell, Michael S.; Fancher, Tammy S.; Freeman, Aaron T.; Ziegler, Abra E.; Bowen, Zachary H.; Aldridge, Cameron L.
2014-01-01
The U.S. Geological Survey Fort Collins Science Center created statewide roads data for the Bureau of Land Management Wyoming State Office using 2009 aerial photography from the National Agriculture Imagery Program. The updated roads data resolves known concerns of omission, commission, and inconsistent representation of map scale, attribution, and ground reference dates which were present in the original source data. To ensure a systematic and repeatable approach of capturing roads on the landscape using on-screen digitizing from true color National Agriculture Imagery Program imagery, we developed a photogrammetry key and quality assurance/quality control protocols. Therefore, the updated statewide roads data will support the Bureau of Land Management’s resource management requirements with a standardized map product representing 2009 ground conditions. The updated Geographic Information System roads data set product, represented at 1:4,000 and +/- 10 meters spatial accuracy, contains 425,275 kilometers within eight attribute classes. The quality control of these products indicated a 97.7 percent accuracy of aspatial information and 98.0 percent accuracy of spatial locations. Approximately 48 percent of the updated roads data was corrected for spatial errors of greater than 1 meter relative to the pre-existing road data. Twenty-six percent of the updated roads involved correcting spatial errors of greater than 5 meters and 17 percent of the updated roads involved correcting spatial errors of greater than 9 meters. The Bureau of Land Management, other land managers, and researchers can use these new statewide roads data set products to support important studies and management decisions regarding land use changes, transportation and planning needs, transportation safety, wildlife applications, and other studies.
DOT National Transportation Integrated Search
2011-03-01
Traffic Management applications such as ramp metering, incident detection, travel time prediction, and vehicle : classification greatly depend on the accuracy of data collected from inductive loop detectors, but these data are : prone to various erro...
DuBay, Derek A; Ivankova, Nataliya; Herby, Ivan; Schoenberger, Yu-Mei; Redden, David T; Holt, Cheryl; Siminoff, Laura; Fouad, Mona; Martin, Michelle Y
2017-01-01
African Americans (AA) are a third as likely as Caucasians to become registered organ donors at the Department of Motorized Vehicles (DMV). The Department of Health and Human Services has set the goal that at least 50% of adults in each state are registered donors. The purpose of this study was to explore the personal, behavioral and environmental factors associated with AA donor registration decision-making at the DMV. Guided by the Social Cognitive Theory, 13 focus groups (n = 100 participants) were conducted with AAs within 3 months of visiting a DMV and making a decision regarding whether to become or to not become a registered donor. The data were analyzed using inductive thematic and qualitative content analyses. Study participants expressed a desire to learn more information while waiting in line at the DMV. Knowing a family member or friend in need of an organ transplant, and the desire to make one's own decision were two salient factors associated with the decision to become a registered organ donor. Several aspects of the DMV environment (e.g., noisy, overcrowded, lacking privacy) were cited as deterrents to becoming a registered donor. This study highlights the personal, behavioral and environmental factors associated with AA organ donor registration decision-making at the DMV. The DMV is a setting where many adults make a decision about organ donation. Policies that create an environment in the DMV to support informed decision-making (e.g., privacy, informed clerks, available educational materials, etc.) are indicated. Copyright © 2017 National Medical Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Christensen, Gary E.; Williamson, Jeffrey F.; Chao, K. S. C.; Miller, Michael I.; So, F. B.; Vannier, Michael W.
1997-10-01
This paper describes a new method to register serial, volumetric x-ray computed tomography (CT) data sets for tracking soft-tissue deformation caused by insertion of intracavity brachytherapy applicators to treat cervical cancer. 3D CT scans collected from the same patient with and without a brachytherapy applicator are registered to aid in computation of the radiation dose to tumor and normal tissue. The 3D CT image volume of pelvic anatomy with the applicator. Initial registration is accomplished by rigid alignment of the pelvic bones and non-rigid alignment of gray scale CT data and hand segmentations of the vagina, cervix, bladder, and rectum. A viscous fluid transformation model is used for non-rigid registration to allow for local, non-linear registration of the vagina, cervix, bladder, and rectum without disturbing the rigid registration of the bony pelvis and adjacent structures. Results are presented in which two 3D CT data sets of the same patient - imaged with and without a brachytherapy applicator - are registered.
Dyson, Lyn; Hedgecock, Bronwyn; Tomkins, Sharon; Cooke, Gordon
2009-11-01
Ongoing education for the nursing workforce is necessary to ensure currency of knowledge in order to enable evidence based client care. The cost of education is high to the organisation and the individual, and must therefore be cost-effective, relevant and appropriate. According to research, education for nurses is not always systematically planned and developed and often relies on the interest area and assessment of the nurse educators. To survey the learning needs of clinically based registered nurses within an acute care setting. An anonymous questionnaire was used to collect the data. Two groups completed the questionnaire: all eligible registered nurses in two acute care hospitals located in urban New Zealand and their senior nurses such as clinical nurse managers, specialists and educators. The study found agreement on learning needs and also noted differing opinions between the Registered Nurses (RNs), and their senior RNs, RNs initially registered overseas and between levels of practice, on selection and ranking of learning needs. This survey identified a number of high learning needs for RNs working within acute care settings. Differences in perception of learning needs for RNs, between the nurses themselves and the Senior RNs exist, as well as among sub groups of RNs. As a result, educators and managers are encouraged to collaborate to realise the opportunity which exists for the provision of education across specialty areas and to work with the different groups and the individual to ensure unique learning needs are met.
Chapter 8: Web-based Tools - CARNIVORE
NASA Astrophysics Data System (ADS)
Graham, M. J.
Registries are an integral part of the VO infrastructure, yet the greatest exposure that most users will ever need to have to one is discovering resources through a registry portal. Some users, however, will have resources of their own that they need to register and will go to an existing registry to do so, but a small number will want to set up their own registry. They may have too many resources to register with an existing registry; they may want more control over their resource metadata than an existing registry will afford; or they may want to set up a specialized registry, e.g. a subjectspecific one. CARNIVORE is designed to offer those who want their own registry the functionality they require in an off-the-shelf implementation. This chapter describes how to set up your own registry using CARNIVORE.
Gschwind, Michael K
2013-04-16
Mechanisms for generating and executing programs for a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA) are provided. A computer program product comprising a computer recordable medium having a computer readable program recorded thereon is provided. The computer readable program, when executed on a computing device, causes the computing device to receive one or more instructions and execute the one or more instructions using logic in an execution unit of the computing device. The logic implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA), based on data stored in a vector register file of the computing device. The vector register file is configured to store both scalar and floating point values as vectors having a plurality of vector elements.
40 CFR 164.22 - Contents of document setting forth objections.
Code of Federal Regulations, 2011 CFR
2011-07-01
... objections. 164.22 Section 164.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... RODENTICIDE ACT, ARISING FROM REFUSALS TO REGISTER, CANCELLATIONS OF REGISTRATIONS, CHANGES OF CLASSIFICATIONS... registration, or change the classification of a pesticide, shall clearly and concisely set forth such...
40 CFR 164.22 - Contents of document setting forth objections.
Code of Federal Regulations, 2010 CFR
2010-07-01
... objections. 164.22 Section 164.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... RODENTICIDE ACT, ARISING FROM REFUSALS TO REGISTER, CANCELLATIONS OF REGISTRATIONS, CHANGES OF CLASSIFICATIONS... registration, or change the classification of a pesticide, shall clearly and concisely set forth such...
78 FR 645 - Federal Employee Pay Schedules and Rates That Are Set by Administrative Discretion
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-03
...--Federal Employee Pay Schedules and Rates That Are Set by Administrative Discretion Executive Order 13635--Adjustments of Certain Rates of Pay #0; #0; #0; Presidential Documents #0; #0; #0;#0;Federal Register / Vol... President [[Page 647
New products from the shuttle radar topography mission
Gesch, Dean B.; Farr, Tom; Slater, James; Muller, Jan-Peter; Cook, Sally
2006-01-01
Final products include elevation data resulting from a substantial editing effort by the NGA in which water bodies and coastlines were well defined and data artifacts known as spikes and wells (single pixel errors) were removed. This second version of the SRTM data set, also referred to as ‘finished’ data, represents a significant improvement over earlier versions that had nonflat water bodies, poorly defined coastlines, and numerous noise artifacts. The edited data are available at a one-arc-second resolution (approximately 30 meters) for the United States and its territories, and at a three-arc-second resolution (approximately 90 meters) for non-U.S. areas.
Canuteson, E L; Zumberge, M
1996-07-01
In an absolute gravity meter, a laser interferometer measures the position of a test mass that is falling ina vacuum. The calculated value of gravity is the average acceleration of the mass during a set ofdrops. Since systematic accelerations of the optical system will bias the measured value of gravity,various interferometer geometries have been implemented in the past to isolate the optical system fromground motion. We have developed and tested a low-finesse fiber-optic extrinsic Fabry-Perotinterferometer that is fixed to the mass of a critically damped seismometer in which the effects ofsystematic ground motion and acoustic vibrations are reduced.
IT Security Standards and Legal Metrology - Transfer and Validation
NASA Astrophysics Data System (ADS)
Thiel, F.; Hartmann, V.; Grottker, U.; Richter, D.
2014-08-01
Legal Metrology's requirements can be transferred into the IT security domain applying a generic set of standardized rules provided by the Common Criteria (ISO/IEC 15408). We will outline the transfer and cross validation of such an approach. As an example serves the integration of Legal Metrology's requirements into a recently developed Common Criteria based Protection Profile for a Smart Meter Gateway designed under the leadership of the Germany's Federal Office for Information Security. The requirements on utility meters laid down in the Measuring Instruments Directive (MID) are incorporated. A verification approach to check for meeting Legal Metrology's requirements by their interpretation through Common Criteria's generic requirements is also presented.
Turnover of registered nurses in Israel: characteristics and predictors.
Toren, Orly; Zelker, Revital; Lipschuetz, Michal; Riba, Shoshana; Reicher, Sima; Nirel, Nurit
2012-05-01
In an era of global and local nursing shortages, nursing turnover has negative consequences in terms of diminished quality of care, increased costs and economic losses and decreased job satisfaction. To examine the turnover rate of registered nurses in Israel by assessing the varying degree of turnover between economic sectors, between hospital and community facilities, and/or between types of hospitals; and by examining potential predicting factors of turnover among registered nurses. A national phone survey was undertaken in Israel consisting of a random sampling of registered nurses of working age (up to age 60). The subjects comprised 10% of a national database of 32,000 registered nurses. The turnover rate among working nurses in Israel currently stands at 23%. In addition, 13% of employed nurses have taken a temporary leave of absence for a period greater than 6 months in the past 10 years, most up to 1 year. While job satisfaction rates were relatively high (72%), Professional satisfaction rates were 60% with no significant difference between hospital and community nurses. The turnover rate of registered nurses from a hospital setting to the community was significantly higher (p<.01) than that of community registered nurses to hospitals. Predicting factors of turnover were found to be: young age, part-time work, lack of advanced professional education, academic education and low satisfaction with the nursing profession. The shift of nursing workforce is mainly from hospitals to community health settings. There is a need to monitor and understand the characteristics of job and professional satisfaction among hospital nurses in order to implement crucial organizational interventions and retain hospital nursing staffs. Since young nurses, nurses working part time and nurses with no advanced professional and academic education, tend to move more than others, efforts should be targeted at these specific groups. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Lukewich, Julia; Edge, Dana S.; VanDenKerkhof, Elizabeth; Williamson, Tyler; Tranmer, Joan
2016-01-01
Background: As the organization of primary care continues to evolve toward more interdisciplinary team structures, demonstrating effectiveness of care delivery is becoming important, particularly for nonphysician providers. Nurses are the most common nonphysician provider within primary care. The purpose of this study was to examine the relation between primary care delivery models that incorporate registered nurses and clinical outcomes of patients with type 2 diabetes. Methods: Patient data from the Canadian Primary Care Sentinel Surveillance Network were matched with survey data from 15 Family Health Team practices in southeastern Ontario. Included patients were adults with type 2 diabetes mellitus who had at least 1 primary care encounter at a Family Health Team practice that completed the organizational survey between Apr. 1, 2013, and Mar. 31, 2014. The clinical outcomes explored included hemoglobin A1c, fasting plasma glucose, blood pressure, low-density lipoprotein cholesterol and urine albumin:creatinine ratio. Results: Of the 15 practices, 13 (86.7%) had at least 1 registered nurse. The presence of 1 or more registered nurses in the practice was associated with increased odds of patients' having their hemoglobin A1c, fasting plasma glucose, blood pressure and low-density lipoprotein cholesterol values meet recommended targets. Practices with the lowest ratios of patients with diabetes to registered nurse had a significantly greater proportion of patients with hemoglobin A1c and fasting plasma glucose values on target than did practices with the highest ratios of patients to registered nurse (p < 0.01 and p = 0.03, respectively). Interpretation: The findings suggest that registered nurse staffing within primary care practice teams contributes to better diabetic care, as measured by diabetes management indicators. This study sets the groundwork for further exploration of nursing and organizational contributions to patient care in the primary care setting. PMID:27398372
Thorat, Yogesh T; Salvi, Sundeep S; Kodgule, Rahul R
2017-05-09
Peak flow meter with questionnaire and mini-spirometer are considered as alternative tools to spirometry for screening of asthma and chronic obstructive pulmonary disease. However, the accuracy of these tools together, in clinical settings for disease diagnosis, has not been studied. Two hundred consecutive patients with respiratory complaints answered a short symptom questionnaire and performed peak expiratory flow measurements, standard spirometry with Koko spirometer and mini-spirometry (COPD-6). Spirometry was repeated after bronchodilation. Physician made a final diagnosis of asthma, chronic obstructive pulmonary disease and others. One eighty nine patients (78 females) with age 51 ± 17 years with asthma (115), chronic obstructive pulmonary disease (33) and others (41) completed the study. "Breathlessness > 6months" and "cough > 6months" were important symptoms to detect obstructive airways disease. "Asymptomatic period > 2 weeks" had the best sensitivity (Sn) and specificity (Sp) to differentiate asthma and chronic obstructive pulmonary disease. A peak expiratory flow of < 80% predicted was the best cut-off to detect airflow limitation (Sn 90%, Sp 50%). Respiratory symptoms with PEF < 80% predicted, had Sn 84 and Sp 93% to detect OAD. COPD-6 device under-estimated FEV 1 by 13 mL (95% CI: -212, 185). At a cut-off of 0.75, the FEV 1 /FEV 6 had the best accuracy (Sn 80%, Sp 86%) to detect airflow limitation. Peak flow meter with few symptom questions can be effectively used in clinical practice for objective detection of asthma and chronic obstructive pulmonary disease, in the absence of good quality spirometry. Mini-spirometers are useful in detection of obstructive airways diseases but FEV 1 measured is inaccurate. DIFFERENTIATING CONDITIONS IN POORLY-EQUIPPED SETTINGS: A simple questionnaire and peak flow meter measurements can help doctors differentiate between asthma and chronic lung disease. In clinical settings where access to specialist equipment and knowledge is limited, it can be challenging for doctors to tell the difference between asthma and chronic obstructive pulmonary disease (COPD). To determine a viable alternative method for differentiating between these diseases, Rahul Kodgule and colleagues at the Chest Research Foundation in Pune, India, trialed a simplified version of two existing symptom questionnaires, combined with peak flow meter measurements. They assessed 189 patients using this method, and found it aided diagnosis with high sensitivity and specificity. Breathlessness, cough and wheeze were the minimal symptoms required for COPD diagnosis, while the length of asymptomatic periods was most helpful in distinguishing asthma from COPD.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-30
... potential problems, set priorities, and take appropriate steps to reduce any potential risks to human health... not be disclosed except in accordance with procedures set forth in 40 CFR part 2. II. Introduction... Tribes, which is published periodically in the Federal Register. As also set forth at 40 CFR 372.3...
Role strain among male RNs in the critical care setting: Perceptions of an unfriendly workplace.
Carte, Nicholas S; Williams, Collette
2017-12-01
Traditionally, nursing has been a female-dominated profession. Men employed as registered nurses have been in the minority and little is known about the experiences of this demographic. The purpose of this descriptive, quantitative study was to understand the relationship between the variables of demographics and causes of role strain among male nurses in critical care settings. The Sherrod Role Strain Scale assesses role strain within the context of role conflict, role overload, role ambiguity and role incongruity. Data analysis of the results included descriptive and inferential statistics. Inferential statistics involved the use of repeated measures ANOVA testing for significant difference in the causes of role strain between male nurses employed in critical care settings and a post hoc comparison of specific demographic data using multivariate analyses of variance (MANOVAs). Data from 37 male nurses in critical care settings from the northeast of the United States were used to calculate descriptive statistics standard deviation, mean of the data analysis and results of the repeated ANOVA and the post hoc secondary MANOVA analysis. The descriptive data showed that all participants worked full-time. There was an even split from those participants who worked day shift (46%) vs. night shift (43%), most the participants indicated they had 15 years or more experience as an registered nurse (54%). Significant findings of this study include two causes of role strain in male nurses employed in critical care settings which are: role ambiguity and role overload based on ethnicity. Consistent with previous research findings, the results of this study suggest that male registered nurses employed in critical care settings do experience role strain. The two main causes of role strain in male nurses are role ambiguity and role overload. Copyright © 2017. Published by Elsevier Ltd.
Realising dignity in care home practice: an action research project.
Gallagher, Ann; Curtis, Katherine; Dunn, Michael; Baillie, Lesley
2017-06-01
More than 400,000 older people reside in over 18,000 care homes in England. A recent social care survey found up to 50% of older people in care homes felt their dignity was undermined. Upholding the dignity of older people in care homes has implications for residents' experiences and the role of Registered Nurses. The study aimed to explore how best to translate the concept of dignity into care home practice, and how to support this translation process by enabling Registered Nurses to provide ethical leadership within the care home setting. Action research with groups of staff (Registered Nurses and non-registered caregivers) and groups of residents and relatives in four care homes in the south of England to contribute to the development of the dignity toolkit. Action research groups were facilitated by 4 researchers (2 in each care home) to discuss dignity principles and experiences within care homes. These groups reviewed and developed a dignity toolkit over six cycles of activity (once a month for 6 months). The Registered Nurses were individually interviewed before and after the activity. Hard copy and online versions of a dignity toolkit, with tailored versions for participating care homes, were developed. Registered Nurses and caregivers identified positive impact of making time for discussion about dignity-related issues. Registered Nurses identified ongoing opportunities for using their toolkit to support all staff. Nurses and caregivers expressed feelings of empowerment by the process of action research. The collaborative development of a dignity toolkit within each care home has the potential to enable ethical leadership by Registered Nurses that would support and sustain dignity in care homes. Action research methods empower staff to maintain dignity for older people within the care home setting through the development of practically useful toolkits to support everyday care practice. Providing opportunities for caregivers to be involved in such initiatives may promote their dignity and sense of being valued. The potential of bottom-up collaborative approaches to promote dignity in care therefore requires further research. © 2016 John Wiley & Sons Ltd.
Real time, TV-based, point-image quantizer and sorter
Case, Arthur L.; Davidson, Jackson B.
1976-01-01
A device is provided for improving the vertical resolution in a television-based, two-dimensional readout for radiation detection systems such as are used to determine the location of light or nuclear radiation impinging a target area viewed by a television camera, where it is desired to store the data indicative of the centroid location of such images. In the example embodiment, impinging nuclear radiation detected in the form of a scintillation occurring in a crystal is stored as a charge image on a television camera tube target. The target is scanned in a raster and the image position is stored according to a corresponding vertical scan number and horizontal position number along the scan. To determine the centroid location of an image that may overlap a number of horizontal scan lines along the vertical axis of the raster, digital logic circuits are provided with at least four series-connected shift registers, each having 512 bit positions according to a selected 512 horizontal increment of resolutions along a scan line. The registers are shifted by clock pulses at a rate of 512 pulses per scan line. When an image or portion thereof is detected along a scan, its horizontal center location is determined and the present front bit is set in the first shift register and shifted through the registers one at a time for each horizontal scan. Each register is compared bit-by-bit with the preceding register to detect coincident set bit positions until the last scan line detecting a portion of the image is determined. Depending on the number of shift registers through which the first detection of the image is shifted, circuitry is provided to store the vertical center position of the event according to the number of shift registers through which the first detection of the event is shifted. Interpolation circuitry is provided to determine if the event centroid is between adjacent scan lines and stored in a vertical address accordingly. The horizontal location of the event is stored in a separate address memory.
Analysis of a multisensor image data set of south San Rafael Swell, Utah
NASA Technical Reports Server (NTRS)
Evans, D. L.
1982-01-01
A Shuttle Imaging Radar (SIR-A) image of the southern portion of the San Rafael Swell in Utah has been digitized and registered to coregistered Landsat, Seasat, and HCMM thermal inertia images. The addition of the SIR-A image to the registered data set improves rock type discrimination in both qualitative and quantitative analyses. Sedimentary units can be separated in a combined SIR-A/Seasat image that cannot be seen in either image alone. Discriminant Analyses show that the classification accuracy is improved with addition of the SIR-A image to Landsat images. Classification accuracy is further improved when texture information from the Seasat and SIR-A images is included.
Pfützner, Andreas; Musholt, Petra B; Schipper, Christina; Demircik, Filiz; Hengesbach, Carina; Flacke, Frank; Sieber, Jochen; Forst, Thomas
2013-11-01
Hematocrit (HCT) is known to be a confounding factor that interferes with many blood glucose (BG) measurement technologies, resulting in wrong readings. Dynamic electrochemistry has been identified as one possible way to correct for these potential deviations. The purpose of this laboratory investigation was to assess the HCT stability of four BG meters known to employ dynamic electrochemistry (BGStar and iBGStar, Sanofi; Wavesense Jazz, AgaMatrix; Wellion Linus, MedTrust) in comparison with three other devices (GlucoDock, Medisana; OneTouch Verio Pro, LifeScan; FreeStyle Freedom InsuLinx, Abbott-Medisense). Venous heparinized blood was immediately aliquoted after draw and manipulated to contain three different BG concentrations (60-90, 130-160, and 280-320 mg/dl) and five different HCT levels (25%, 35%, 45%, 55%, and 60%). After careful oxygenation to normal blood oxygen pressure, each of the resulting 15 different samples was measured six times with three devices and three strip lots of each meter. The YSI Stat 2300 served as laboratory reference method. Stability to HCT influence was assumed when less than 10% difference occurred between the highest and lowest mean glucose deviations in relation to HCT concentrations [hematocrit interference factor (HIF)]. Five of the investigated self-test meters showed a stable performance with the different HCT levels tested in this investigation: BGStar (HIF 4.6%), iBGStar (6.6%), Wavesense Jazz (4.1%), Wellion Linus (8.5%), and OneTouch Verio Pro (6.2%). The two other meters were influenced by HCT (FreeStyle InsuLinx 17.8%; GlucoDock 46.5%). In this study, meters employing dynamic electrochemistry, as used in the BGStar and iBGStar devices, were shown to correct for potential HCT influence on the meter results. Dynamic electrochemistry appears to be an effective way to handle this interfering condition. © 2013 Diabetes Technology Society.
Patino, Eduardo
1996-01-01
A field experiment was conducted at the Levee 4 canal site below control structure G-88 in the Everglades agricultural area in northwestern Broward County, Florida, to study the relation of acoustic attenuation to suspended-solids concentrations. Acoustic velocity meter and temperature data were obtained with concurrent water samples analyzed for suspended-solids concentrations. Two separate acoustic velocity meter frequencies were used, 200 and 500 kilohertz, to determine the sensitivity of acoustic attenuation to frequency for the measured suspended-solids concentration range. Suspended-solids concentrations for water samples collected at the Levee 4 canal site from July 1993 to September 1994 ranged from 22 to 1,058 milligrams per liter, and organic content ranged from about 30 to 93 percent. Regression analyses showed that attenuation data from the acoustic velocity meter (automatic gain control) and temperature data alone do not provide enough information to adequately describe the concentrations of suspended solids. However, if velocity is also included as one of the independent variables in the regression model, a satisfactory correlation can be obtained. Thus, it is feasible to use acoustic velocity meter instrumentation to estimate suspended-solids concentrations in streams, even when suspended solids are primarily composed of organic material. Using the most comprehensive data set available for the study (500 kiloherz data), the best fit regression model produces a standard error of 69.7 milligrams per liter, with actual errors ranging from 2 to 128 milligrams per liter. Both acoustic velocity meter transmission frequencies of 200 and 500 hilohertz produced similar results, suggesting that transducers of either frequency could be used to collect attenuation data at the study site. Results indicate that calibration will be required for each acoustic velocity meter system to the unique suspended-solids regime existing at each site. More robust solutions may be defined in streams with suspended solids having lower percentages of organic composition.
Pfützner, Andreas; Musholt, Petra B.; Schipper, Christina; Demircik, Filiz; Hengesbach, Carina; Flacke, Frank; Sieber, Jochen; Forst, Thomas
2013-01-01
Background Hematocrit (HCT) is known to be a confounding factor that interferes with many blood glucose (BG) measurement technologies, resulting in wrong readings. Dynamic electrochemistry has been identified as one possible way to correct for these potential deviations. The purpose of this laboratory investigation was to assess the HCT stability of four BG meters known to employ dynamic electrochemistry (BGStar and iBGStar, Sanofi; Wavesense Jazz, AgaMatrix; Wellion Linus, MedTrust) in comparison with three other devices (GlucoDock, Medisana; OneTouch Verio Pro, LifeScan; FreeStyle Freedom InsuLinx, Abbott-Medisense). Methods Venous heparinized blood was immediately aliquoted after draw and manipulated to contain three different BG concentrations (60–90, 130–160, and 280–320 mg/dl) and five different HCT levels (25%, 35%, 45%, 55%, and 60%). After careful oxygenation to normal blood oxygen pressure, each of the resulting 15 different samples was measured six times with three devices and three strip lots of each meter. The YSI Stat 2300 served as laboratory reference method. Stability to HCT influence was assumed when less than 10% difference occurred between the highest and lowest mean glucose deviations in relation to HCT concentrations [hematocrit interference factor (HIF)]. Results Five of the investigated self-test meters showed a stable performance with the different HCT levels tested in this investigation: BGStar (HIF 4.6%), iBGStar (6.6%), Wavesense Jazz (4.1%), Wellion Linus (8.5%), and OneTouch Verio Pro (6.2%). The two other meters were influenced by HCT (FreeStyle InsuLinx 17.8%; GlucoDock 46.5%). Conclusions In this study, meters employing dynamic electrochemistry, as used in the BGStar and iBGStar devices, were shown to correct for potential HCT influence on the meter results. Dynamic electrochemistry appears to be an effective way to handle this interfering condition. PMID:24351179
Basic study on hot-wire flow meter in forced flow of liquid hydrogen
NASA Astrophysics Data System (ADS)
Oura, Y.; Shirai, Y.; Shiotsu, M.; Murakami, K.; Tatsumoto, H.; Naruo, Y.; Nonaka, S.; Kobayashi, H.; Inatani, Y.; Narita, N.
2014-01-01
Liquid hydrogen (LH2) is a key issue in a carbon-free energy infrastructure at the energy storage and transportation stage. The typical features of LH2 are low viscosity, large latent heat and small density, compared with other general liquids. It is necessary to measure a mass flow of liquid hydrogen with a simple and compact method, especially in a two phase separate flow condition. We have proposed applying a hot-wire type flow meter, which is usually used a for gas flow meter, to LH2 flow due to the quite low viscosity and density. A test model of a compact LH2 hot-wire flow meter to measure local flow velocities near and around an inside perimeter of a horizontal tube by resistance thermometry was designed and made. The model flow meter consists of two thin heater wires made of manganin fixed in a 10 mm-diameter and 40 mm-length tube flow path made of GFRP. Each rigid heater wire was set twisted by 90 degrees from the inlet to the outlet along the inner wall. In other words, the wires were aslant with regard to the LH2 stream line. The heated wire was cooled by flowing LH2, and the flow velocity was obtained by means of the difference of the cooling characteristic in response to the flow velocity. In this report, we show results on the basic experiments with the model LH2 hot-wire flow meter. First, the heat transfer characteristics of the two heater wires for several LH2 flow velocities were measured. Second, the heating current was controlled to keep the wire temperature constant for various flow velocities. The relations between the flow velocity and the heating current were measured. The feasibility of the proposed model was confirmed.
Baum, John M; Monhaut, Nanette M; Parker, Donald R; Price, Christopher P
2006-06-01
Two independent studies reported that 16% of people who self-monitor blood glucose used incorrectly coded meters. The degree of analytical error, however, was not characterized. Our study objectives were to demonstrate that miscoding can cause analytical errors and to characterize the potential amount of bias that can occur. The impact of calibration error with three selfblood glucose monitoring systems (BGMSs), one of which has an autocoding feature, is reported. Fresh capillary fingerstick blood from 50 subjects, 18 men and 32 women ranging in age from 23 to 82 years, was used to measure glucose with three BGMSs. Two BGMSs required manual coding and were purposely miscoded using numbers different from the one recommended for the reagent lot used. Two properly coded meters of each BGMS were included to assess within-system variability. Different reagent lots were used to challenge a third system that had autocoding capability and could not be miscoded. Some within-system comparisons showed deviations of greater than +/-30% when results obtained with miscoded meters were compared with data obtained with ones programmed using the correct code number. Similar erroneous results were found when the miscoded meter results were compared with those obtained with a glucose analyzer. For some miscoded meter and test strip combinations, error grid analysis showed that 90% of results fell into zones indicating altered clinical action. Such inaccuracies were not found with the BGMS having the autocoding feature. When certain meter code number settings of two BGMSs were used in conjunction with test strips having code numbers that did not match, statistically and clinically inaccurate results were obtained. Coding errors resulted in analytical errors of greater than +/-30% (-31.6 to +60.9%). These results confirm the value of a BGMS with an automatic coding feature.
Exploring the energy benefits of advanced water metering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, Michael A.; Hans, Liesel; Piscopo, Kate
Recent improvements to advanced water metering and communications technologies have the potential to improve the management of water resources and utility infrastructure, benefiting both utilities and ratepayers. The highly granular, near-real-time data and opportunity for automated control provided by these advanced systems may yield operational benefits similar to those afforded by similar technologies in the energy sector. While significant progress has been made in quantifying the water-related benefits of these technologies, the research on quantifying the energy benefits of improved water metering is underdeveloped. Some studies have quantified the embedded energy in water in California, however these findings are basedmore » on data more than a decade old, and unanimously assert that more research is needed to further explore how topography, climate, water source, and other factors impact their findings. In this report, we show how water-related advanced metering systems may present a broader and more significant set of energy-related benefits. We review the open literature of water-related advanced metering technologies and their applications, discuss common themes with a series of water and energy experts, and perform a preliminary scoping analysis of advanced water metering deployment and use in California. We find that the open literature provides very little discussion of the energy savings potential of advanced water metering, despite the substantial energy necessary for water’s extraction, conveyance, treatment, distribution, and eventual end use. We also find that water AMI has the potential to provide water-energy co-efficiencies through improved water systems management, with benefits including improved customer education, automated leak detection, water measurement and verification, optimized system operation, and inherent water and energy conservation. Our findings also suggest that the adoption of these technologies in the water sector has been slow, due to structural economic and regulatory barriers. In California, we see examples of deployed advanced metering systems with demonstrated embedded energy savings through water conservation and leak detection. Finally, we also see substantial untapped opportunity in the agricultural sector for enabling electric demand response for both traditional peak shaving and more complex flexible and ancillary services through improved water tracking and farm automation.« less
Hofer, Philipp; Fiegl, Heidi; Angerer, Justina; Mueller-Holzner, Elisabeth; Chamson, Martina; Klocker, Helmut; Steiner, Eberhardt; Hauffe, Helga; Zschocke, Johannes; Goebel, Georg
2014-01-01
The knowledge about the quality of samples and associated clinical data in biospecimen collections is a premise of clinical research. An electronic biosample register aims to facilitate the discovery of information about biosample collections in a hospital. Moreover, it might improve scientific collaboration and research quality through a shared access to harmonized sample collection description data. The aim of this paper is to present a concept of a web-based biosample register of the existing biosample collections at the Medical University of Innsbruck. A uniform description model is built based on an analysis of the sample collection data of independent sample management systems from two departments within the hospital. An extended set of attributes of the minimum dataset used by the Swedish sample collection register (MIABIS) has been applied to all biosample collections as a common description model. The results of the analysis and the data model are presented together with a first concept of a sample collection search register.
NASA Technical Reports Server (NTRS)
Janoudi, A.; Poff, K. L.
1990-01-01
The relationship between the amount of light and the amount of response for any photobiological process can be based on the number of incident quanta per unit time (fluence rate-response) or on the number of incident quanta during a given period of irradiation (fluence-response). Fluence-response and fluence rate-response relationships have been measured for second positive phototropism by seedlings of Arabidopsis thaliana. The fluence-response relationships exhibit a single limiting threshold at about 0.01 micromole per square meter when measured at fluence rates from 2.4 x 10(-5) to 6.5 x 10(-3) micromoles per square meter per second. The threshold values in the fluence rate-response curves decrease with increasing time of irradiation, but show a common fluence threshold at about 0.01 micromole per square meter. These thresholds are the same as the threshold of about 0.01 micromole per square meter measured for first positive phototropism. Based on these data, it is suggested that second positive curvature has a threshold in time of about 10 minutes. Moreover, if the times of irradiation exceed the time threshold, there is a single limiting fluence threshold at about 0.01 micromole per square meter. Thus, the limiting fluence threshold for second positive phototropism is the same as the fluence threshold for first positive phototropism. Based on these data, we suggest that this common fluence threshold for first positive and second positive phototropism is set by a single photoreceptor pigment system.
Simplified microprocessor design for VLSI control applications
NASA Technical Reports Server (NTRS)
Cameron, K.
1991-01-01
A design technique for microprocessors combining the simplicity of reduced instruction set computers (RISC's) with the richer instruction sets of complex instruction set computers (CISC's) is presented. They utilize the pipelined instruction decode and datapaths common to RISC's. Instruction invariant data processing sequences which transparently support complex addressing modes permit the formulation of simple control circuitry. Compact implementations are possible since neither complicated controllers nor large register sets are required.
Hommel, Ami; Bååth, Carina
2016-06-01
The Swedish healthcare system has a unique resource in the national quality registers. A national quality registry contains individualised data concerning patient problems, medical interventions and outcomes after treatment, within all healthcare settings. Many healthcare settings face challenges related to the way they deliver the fundamentals of care, therefore, it is important to audit the outcome. It is estimated that the number of people aged 80 years or older will have almost quadrupled between 2000 and 2050. Hip fracture has been recognised as the most serious consequence of osteoporosis because of the risk of its complications, which include pain, acute confusional state, pressure ulcers, infections, disability, diminished quality of life and mortality. The aim of this study was therefore to explore if and how a national quality register can be used as an audit tool for the fundamentals of care when it concerns older patients suffering from a hip fracture. For this study we retrospectively selected and audited variables retrieved from the national quality hip fracture register. The audit included 1083 patients 80 years and older, consecutively admitted to a university hospital in the south of Sweden, in 2011-2013. Nearly half of the patients were admitted from their own homes and were living alone. Almost half of the patients could walk outdoors before the fracture occurred. After 4 months, 28.5% of the patients walked outdoors. Additionally, after 4 months about 30% of the patients were still suffering from pain after hip fracture surgery and still using analgesics. There was a reduction in length of stay between 2011 and 2013. As a part of the national quality register the questions from EQ5D were used before surgery and after 4 months. Before discharge from hospital there were less registered complications in 2012 and 2013 compared with 2011. The national hip fracture quality register allows healthcare staff to analyse nursing outcomes and to highlight some fundamental aspects of care. Greater awareness, among hospital staff, of risk factors for complications in hip fracture patients may lead to improved patient care. Through registration in a quality register and working with the results we as Registered Nurses can ensure quality health care for older adults. © 2015 John Wiley & Sons Ltd.
Row-crop planter requirements to support variable-rate seeding of maize
USDA-ARS?s Scientific Manuscript database
Current planting technology possesses the ability to increase crop productivity and improve field efficiency by precisely metering and placing crop seeds. Planter performance depends on using the correct planter and technology setup which consists of determining optimal settings for different planti...
Comparison of Clustering Techniques for Residential Energy Behavior using Smart Meter Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Ling; Lee, Doris; Sim, Alex
Current practice in whole time series clustering of residential meter data focuses on aggregated or subsampled load data at the customer level, which ignores day-to-day differences within customers. This information is critical to determine each customer’s suitability to various demand side management strategies that support intelligent power grids and smart energy management. Clustering daily load shapes provides fine-grained information on customer attributes and sources of variation for subsequent models and customer segmentation. In this paper, we apply 11 clustering methods to daily residential meter data. We evaluate their parameter settings and suitability based on 6 generic performance metrics and post-checkingmore » of resulting clusters. Finally, we recommend suitable techniques and parameters based on the goal of discovering diverse daily load patterns among residential customers. To the authors’ knowledge, this paper is the first robust comparative review of clustering techniques applied to daily residential load shape time series in the power systems’ literature.« less
High angular resolution at LBT
NASA Astrophysics Data System (ADS)
Conrad, A.; Arcidiacono, C.; Bertero, M.; Boccacci, P.; Davies, A. G.; Defrere, D.; de Kleer, K.; De Pater, I.; Hinz, P.; Hofmann, K. H.; La Camera, A.; Leisenring, J.; Kürster, M.; Rathbun, J. A.; Schertl, D.; Skemer, A.; Skrutskie, M.; Spencer, J. R.; Veillet, C.; Weigelt, G.; Woodward, C. E.
2015-12-01
High angular resolution from ground-based observatories stands as a key technology for advancing planetary science. In the window between the angular resolution achievable with 8-10 meter class telescopes, and the 23-to-40 meter giants of the future, LBT provides a glimpse of what the next generation of instruments providing higher angular resolution will provide. We present first ever resolved images of an Io eruption site taken from the ground, images of Io's Loki Patera taken with Fizeau imaging at the 22.8 meter LBT [Conrad, et al., AJ, 2015]. We will also present preliminary analysis of two data sets acquired during the 2015 opposition: L-band fringes at Kurdalagon and an occultation of Loki and Pele by Europa (see figure). The light curves from this occultation will yield an order of magnitude improvement in spatial resolution along the path of ingress and egress. We will conclude by providing an overview of the overall benefit of recent and future advances in angular resolution for planetary science.
van Dam, Joris; Musuku, John; Zühlke, Liesl J; Engel, Mark E; Nestle, Nick; Tadmor, Brigitta; Spector, Jonathan; Mayosi, Bongani M
2015-01-01
Rheumatic heart disease (RHD) remains a major disease burden in low-resource settings globally. Patient registers have long been recognised to be an essential instrument in RHD control and elimination programmes, yet to date rely heavily on paper-based data collection and non-networked data-management systems, which limit their functionality. To assess the feasibility and potential benefits of producing an electronic RHD patient register. We developed an eRegister based on the World Heart Federation's framework for RHD patient registers using CommCare, an open-source, cloud-based software for health programmes that supports the development of customised data capture using mobile devices. The resulting eRegistry application allows for simultaneous data collection and entry by field workers using mobile devices, and by providers using computer terminals in clinics and hospitals. Data are extracted from CommCare and are securely uploaded into a cloud-based database that matches the criteria established by the WHF framework. The application can easily be tailored to local needs by modifying existing variables or adding new ones. Compared with traditional paper-based data-collection systems, the eRegister reduces the risk of data error, synchronises in real-time, improves clinical operations and supports management of field team operations. The user-friendly eRegister is a low-cost, mobile, compatible platform for RHD treatment and prevention programmes based on materials sanctioned by the World Heart Federation. Readily adaptable to local needs, this paperless RHD patient register program presents many practical benefits.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Agency for Healthcare Research and Quality Priority Setting for the Children's Health Insurance Program Reauthorization Act (CHIPRA) Pediatric Quality Measures Program--Notice of Correction On pages 75469 and 75470, Volume 75, Number 232, Federal Register...
Developing a Policy for Delegation of Nursing Care in the School Setting
ERIC Educational Resources Information Center
Spriggle, Melinda
2009-01-01
School nurses are in a unique position to provide care for students with special health care needs in the school setting. The incidence of chronic conditions and improved technology necessitate care of complex health care needs that had formerly been managed in inpatient settings. Delegation is a tool that may be used by registered nurses to allow…
Satellite control of electric power distribution
NASA Technical Reports Server (NTRS)
Bergen, L.
1981-01-01
An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.
NASA Astrophysics Data System (ADS)
Golik, Sergey S.; Mayor, Alexsander Yu.; Proschenko, Dmitriy Yu.; Ilyin, Alexey A.; Nagorniy, Ivan G.; Biryukova, Yuliya S.; Babiy, Michael Yu.; Golik, Natalia N.; Gevorgyan, Tigran A.; Lisitsa, Vladimir V.; Borovskiy, Anton V.; Kulchin, Yuri N.
2017-10-01
The developed underwater laser induced breakdown spectrometer consists of two units: 1- remotely operated vehicle (ROV) with the next main characteristics: work deep - up to 150 meters, maximum speed of immersion 1 m/s, maximum cruise velocity - 2 m/s and 2 - spectrometer unit (SU) consist of a DPSS Nd: YAG laser excitation source (double pulse with 50 mJ energy for each pulse at wavelength 1064 nm, pulse width 12 ns and pulse repetition rate 1-15 Hz, DF251, SOL Instruments), a spectrum recording system (Maya HR4000 or 2000 Pro spectrometer, Ocean Optics) and microcomputer. These two units are connected by Ethernet network and registered spectral data are automatically processed in a MATLAB platform.
Quantum information. Unconditional quantum teleportation between distant solid-state quantum bits.
Pfaff, W; Hensen, B J; Bernien, H; van Dam, S B; Blok, M S; Taminiau, T H; Tiggelman, M J; Schouten, R N; Markham, M; Twitchen, D J; Hanson, R
2014-08-01
Realizing robust quantum information transfer between long-lived qubit registers is a key challenge for quantum information science and technology. Here we demonstrate unconditional teleportation of arbitrary quantum states between diamond spin qubits separated by 3 meters. We prepare the teleporter through photon-mediated heralded entanglement between two distant electron spins and subsequently encode the source qubit in a single nuclear spin. By realizing a fully deterministic Bell-state measurement combined with real-time feed-forward, quantum teleportation is achieved upon each attempt with an average state fidelity exceeding the classical limit. These results establish diamond spin qubits as a prime candidate for the realization of quantum networks for quantum communication and network-based quantum computing. Copyright © 2014, American Association for the Advancement of Science.
Stratton, T D; Dunkin, J W; Juhl, N; Geller, J M
1995-05-01
Researchers have demonstrated repeatedly the importance of the relationship linking job satisfaction to employee retention. In rural areas of the country, where a persistent maldistribution of nurses continues to hamper health care delivery, the potential benefits of bolstering retention via enhancements in job satisfaction are of utmost utility to administrators and providers alike. Data were gathered from a multistate survey of registered nurses (RNs) practicing in rural hospitals, skilled nursing facilities, and community/public health settings (N = 1,647; response rate = 40.3%). The investigators found that the use of tuition reimbursement corresponded significantly with increased levels of job satisfaction among nurses in all three practice environments, as did day care services for nurses in acute care settings. Also, among hospital-based RNs, level of nursing education was found to be a significant factor in the relationship between tuition reimbursement and job satisfaction, with the highest level occurring among diploma-prepared nurses.
Poor reporting of scientific leadership information in clinical trial registers.
Sekeres, Melanie; Gold, Jennifer L; Chan, An-Wen; Lexchin, Joel; Moher, David; Van Laethem, Marleen L P; Maskalyk, James; Ferris, Lorraine; Taback, Nathan; Rochon, Paula A
2008-02-20
In September 2004, the International Committee of Medical Journal Editors (ICMJE) issued a Statement requiring that all clinical trials be registered at inception in a public register in order to be considered for publication. The World Health Organization (WHO) and ICMJE have identified 20 items that should be provided before a trial is considered registered, including contact information. Identifying those scientifically responsible for trial conduct increases accountability. The objective is to examine the proportion of registered clinical trials providing valid scientific leadership information. We reviewed clinical trial entries listing Canadian investigators in the two largest international and public trial registers, the International Standard Randomized Controlled Trial Number (ISRCTN) register, and ClinicalTrials.gov. The main outcome measures were the proportion of clinical trials reporting valid contact information for the trials' Principal Investigator (PI)/Co-ordinating Investigator/Study Chair/Site PI, and trial e-mail contact address, stratified by funding source, recruiting status, and register. A total of 1388 entries (142 from ISRCTN and 1246 from ClinicalTrials.gov) comprised our sample. We found non-compliance with mandatory registration requirements regarding scientific leadership and trial contact information. Non-industry and partial industry funded trials were significantly more likely to identify the individual responsible for scientific leadership (OR = 259, 95% CI: 95-701) and to provide a contact e-mail address (OR = 9.6, 95% CI: 6.6-14) than were solely industry funded trials. Despite the requirements set by WHO and ICMJE, data on scientific leadership and contact e-mail addresses are frequently omitted from clinical trials registered in the two leading public clinical trial registers. To promote accountability and transparency in clinical trials research, public clinical trials registers should ensure adequate monitoring of trial registration to ensure completion of mandatory contact information fields identifying scientific leadership.
3DVEM Software Modules for Efficient Management of Point Clouds and Photorealistic 3d Models
NASA Astrophysics Data System (ADS)
Fabado, S.; Seguí, A. E.; Cabrelles, M.; Navarro, S.; García-De-San-Miguel, D.; Lerma, J. L.
2013-07-01
Cultural heritage managers in general and information users in particular are not usually used to deal with high-technological hardware and software. On the contrary, information providers of metric surveys are most of the times applying latest developments for real-life conservation and restoration projects. This paper addresses the software issue of handling and managing either 3D point clouds or (photorealistic) 3D models to bridge the gap between information users and information providers as regards the management of information which users and providers share as a tool for decision-making, analysis, visualization and management. There are not many viewers specifically designed to handle, manage and create easily animations of architectural and/or archaeological 3D objects, monuments and sites, among others. 3DVEM - 3D Viewer, Editor & Meter software will be introduced to the scientific community, as well as 3DVEM - Live and 3DVEM - Register. The advantages of managing projects with both sets of data, 3D point cloud and photorealistic 3D models, will be introduced. Different visualizations of true documentation projects in the fields of architecture, archaeology and industry will be presented. Emphasis will be driven to highlight the features of new userfriendly software to manage virtual projects. Furthermore, the easiness of creating controlled interactive animations (both walkthrough and fly-through) by the user either on-the-fly or as a traditional movie file will be demonstrated through 3DVEM - Live.
Fleminger, Jessica; Goldacre, Ben
2018-01-01
Trial registries are a key source of information for clinicians and researchers. While building OpenTrials, an open database of public trial information, we identified errors and omissions in registries, including discrepancies between descriptions of the same trial in different registries. We set out to ascertain the prevalence of discrepancies in trial completion status using a cohort of trials registered on both the European Union Clinical Trials Register (EUCTR) and ClinicalTrials.gov. We used matching titles and registry IDs provided by both registries to build a cohort of dual-registered trials. Completion statuses were compared; we calculated descriptive statistics on the prevalence of discrepancies. 11,988 dual-registered trials were identified. 1,496 did not provide a comparable completion status, leaving 10,492 trials. 16.2% were discrepant on completion status. The majority of discrepancies (90.5%) were a 'completed' trial on ClinicalTrials.gov inaccurately marked as 'ongoing' on EUCTR. Overall, 33.9% of dual-registered trials described as 'ongoing' on EUCTR were listed as 'completed' on ClinicalTrials.gov. Completion status on registries is commonly inaccurate. Previous work on publication bias may underestimate non-reporting. We describe simple steps registry owners and trialists could take to improve accuracy.
Moreno Berggren, Daniel; Folkvaljon, Yasin; Engvall, Marie; Sundberg, Johan; Lambe, Mats; Antunovic, Petar; Garelius, Hege; Lorenz, Fryderyk; Nilsson, Lars; Rasmussen, Bengt; Lehmann, Sören; Hellström-Lindberg, Eva; Jädersten, Martin; Ejerblad, Elisabeth
2018-06-01
The myelodysplastic syndromes (MDS) have highly variable outcomes and prognostic scoring systems are important tools for risk assessment and to guide therapeutic decisions. However, few population-based studies have compared the value of the different scoring systems. With data from the nationwide Swedish population-based MDS register we validated the International Prognostic Scoring System (IPSS), revised IPSS (IPSS-R) and the World Health Organization (WHO) Classification-based Prognostic Scoring System (WPSS). We also present population-based data on incidence, clinical characteristics including detailed cytogenetics and outcome from the register. The study encompassed 1329 patients reported to the register between 2009 and 2013, 14% of these had therapy-related MDS (t-MDS). Based on the MDS register, the yearly crude incidence of MDS in Sweden was 2·9 per 100 000 inhabitants. IPSS-R had a significantly better prognostic power than IPSS (P < 0·001). There was a trend for better prognostic power of IPSS-R compared to WPSS (P = 0·05) and for WPSS compared to IPSS (P = 0·07). IPSS-R was superior to both IPSS and WPSS for patients aged ≤70 years. Patients with t-MDS had a worse outcome compared to de novo MDS (d-MDS), however, the validity of the prognostic scoring systems was comparable for d-MDS and t-MDS. In conclusion, population-based studies are important to validate prognostic scores in a 'real-world' setting. In our nationwide cohort, the IPSS-R showed the best predictive power. © 2018 John Wiley & Sons Ltd.
Havelin, Leif I; Robertsson, Otto; Fenstad, Anne M; Overgaard, Søren; Garellick, Göran; Furnes, Ove
2011-12-21
The Nordic (Scandinavian) countries have had working arthroplasty registers for several years. However, the small numbers of inhabitants and the conformity within each country with respect to preferred prosthesis brands and techniques have limited register research. A collaboration called NARA (Nordic Arthroplasty Register Association) was started in 2007, resulting in a common database for Denmark, Norway, and Sweden with regard to hip replacements in 2008 and primary knee replacements in 2009. Finland joined the project in 2010. A code set was defined for the parameters that all registers had in common, and data were re-coded, within each national register, according to the common definitions. After de-identification of the patients, the anonymous data were merged into a common database. The first study based on this common database included 280,201 hip arthroplasties and the second, 151,814 knee arthroplasties. Kaplan-Meier and Cox multiple regression analyses, with adjustment for age, sex, and diagnosis, were used to calculate prosthesis survival, with any revision as the end point. In later studies, specific reasons for revision were also used as end points. We found differences among the countries concerning patient demographics, preferred surgical approaches, fixation methods, and prosthesis brands. Prosthesis survival was best in Sweden, where cement implant fixation was used more commonly than it was in the other countries. As the comparison of national results was one of the main initial aims of this collaboration, only parameters and data that all three registers could deliver were included in the database. Compared with each separate register, this combined register resulted in reduced numbers of parameters and details. In future collaborations of registers with a focus on comparing the performances of prostheses and articulations, we should probably include only the data needed specifically for the predetermined purposes, from registers that can deliver these data, rather than compiling all data from all registers that are willing to participate.
The bacterial contamination rate of glucose meter test strips in the hospital setting
Al-Rubeaan, Khalid A.; Saeb, Amr T. M.; AlNaqeb, Dhekra M.; AlQumaidi, Hamed M.; AlMogbel, Turki A.
2016-01-01
Objectives: To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. Methods: This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saudi Arabia during the period from August to September 2014 to assess the bacterial contamination rate of the unused strips. A total of 10,447 strips were cultured using proper agar media and incubated both aerobically and anaerobically. Results: The total bacterial contamination rate for the multi-use vials glucose strips was 31.7%, while single-use packed strips were not contaminated at all. Ministry of Health hospitals had the highest contamination rates compared with other hospitals. Critical, obstetric, and surgical wards had the highest bacterial isolates number, where most were in the risk group 3 according to the National Institute of Health guidelines. Staphylococcus species were the most common bacteria found. Conclusion: Glucose meter strips should be recognized as a source of bacterial contamination that could be behind serious hospital acquired infections. The hospital infection control team should adopt proper measures to implement protocols for glucose meter cleaning and glucose strips handling. PMID:27570855
NASA Astrophysics Data System (ADS)
Yin, Dong-shan; Gao, Yu-ping; Zhao, Shu-hong
2017-07-01
Millisecond pulsars can generate another type of time scale that is totally independent of the atomic time scale, because the physical mechanisms of the pulsar time scale and the atomic time scale are quite different from each other. Usually the pulsar timing observations are not evenly sampled, and the internals between two data points range from several hours to more than half a month. Further more, these data sets are sparse. All this makes it difficult to generate an ensemble pulsar time scale. Hence, a new algorithm to calculate the ensemble pulsar time scale is proposed. Firstly, a cubic spline interpolation is used to densify the data set, and make the intervals between data points uniform. Then, the Vondrak filter is employed to smooth the data set, and get rid of the high-frequency noises, and finally the weighted average method is adopted to generate the ensemble pulsar time scale. The newly released NANOGRAV (North American Nanohertz Observatory for Gravitational Waves) 9-year data set is used to generate the ensemble pulsar time scale. This data set includes the 9-year observational data of 37 millisecond pulsars observed by the 100-meter Green Bank telescope and the 305-meter Arecibo telescope. It is found that the algorithm used in this paper can reduce effectively the influence caused by the noises in pulsar timing residuals, and improve the long-term stability of the ensemble pulsar time scale. Results indicate that the long-term (> 1 yr) stability of the ensemble pulsar time scale is better than 3.4 × 10-15.
27 CFR 29.55 - Registry of stills and distilling apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... distilling apparatus. 29.55 Section 29.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Registry of stills and distilling apparatus. (a) General. Every person having possession, custody, or control of any still or distilling apparatus set up shall, immediately on its being set up, register the...
27 CFR 29.55 - Registry of stills and distilling apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... distilling apparatus. 29.55 Section 29.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Registry of stills and distilling apparatus. (a) General. Every person having possession, custody, or control of any still or distilling apparatus set up shall, immediately on its being set up, register the...
Using electrical resistance probes for moisture determination in switchgrass windrows
USDA-ARS?s Scientific Manuscript database
Determining moisture levels in windrowed biomass is important for both forage producers and researchers. Energy crops such as switchgrass have been troublesome when using the standard methods set for electrical resistance meters. The objectives of this study were to i) develop the methodologies need...
10 CFR 2.1003 - Availability of material.
Code of Federal Regulations, 2013 CFR
2013-01-01
... its license application for a geologic repository, the NRC shall make available no later than thirty... privilege in § 2.1006, graphic-oriented documentary material that includes raw data, computer runs, computer... discrepancies; (ii) Gauge, meter and computer settings; (iii) Probe locations; (iv) Logging intervals and rates...
10 CFR 2.1003 - Availability of material.
Code of Federal Regulations, 2014 CFR
2014-01-01
... its license application for a geologic repository, the NRC shall make available no later than thirty... privilege in § 2.1006, graphic-oriented documentary material that includes raw data, computer runs, computer... discrepancies; (ii) Gauge, meter and computer settings; (iii) Probe locations; (iv) Logging intervals and rates...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
... interconnect sites (meter stations), 12 mainline block valves, 4 pig \\1\\ launchers/ receivers, 2 over-pipeline protection facilities, and 1 side tap valve setting; and \\1\\ A pig is an internal tool that can be used to...
de Olalla, Patricia García; Gracia, José; Rius, Cristina; Caylà, Joan A; Pañella, Helena; Villabí, Joan R; Guix, Joan; Pellicer, Teresa; Ferrer, Dolors; Cusi, Meritxell; Pelaz, Carmen; Sabrià, Miquel
2008-01-01
Description of an outbreak of legionnaires' disease originating in one of the cooling towers of a hospital. This study included patients with confirmed pneumonia caused by Legionella pneumophila serogroup 1 and related to the Vallcarca neighborhood of Barcelona (Spain) in August 2004. Exposure was determined by a standardized questionnaire. An environmental investigation was carried out to identify the source of the outbreak. A descriptive analysis including incidence rates estimation was performed, as well as molecular study to document the genetic identity among human and environmental strains. Thirty-three cases of L. pneumophila pneumonia were detected. Median age was 68 years and 70% of the affected patients were men. Incidence rate among residents in less than 200 meters of the source and older than 65 was 888.9 cases/100,000 inhabitants. Lethality rate was 6%. Four seasonal cooling towers that were not registered with the authorities were identified in a health care center. L. pneumophila was isolated from all four and at least one colony in each tower had the same genetic profile as the strains isolated from patients. An association was demonstrated between a community outbreak of legionellosis and unregistered seasonal cooling towers located in a hospital. All risk facilities should be registered and inspected to ensure that they fulfill current legislation requirements.
Kedzierski, Michal; Fryskowska, Anna
2014-01-01
Visualization techniques have been greatly developed in the past few years. Three-dimensional models based on satellite and aerial imagery are now being enhanced by models generated using Aerial Laser Scanning (ALS) data. The most modern of such scanning systems have the ability to acquire over 50 points per square meter and to register a multiple echo, which allows the reconstruction of the terrain together with the terrain cover. However, ALS data accuracy is less than 10 cm and the data is often incomplete: there is no information about ground level (in most scanning systems), and often around the facade or structures which have been covered by other structures. However, Terrestrial Laser Scanning (TLS) not only acquires higher accuracy data (1–5 cm) but is also capable of registering those elements which are incomplete or not visible using ALS methods (facades, complicated structures, interiors, etc.). Therefore, to generate a complete 3D model of a building in high Level of Details, integration of TLS and ALS data is necessary. This paper presents the wavelet-based method of processing and integrating data from ALS and TLS. Methods of choosing tie points to combine point clouds in different datum will be analyzed. PMID:25004157
Roshani, G H; Nazemi, E; Roshani, M M
2017-05-01
Changes of fluid properties (especially density) strongly affect the performance of radiation-based multiphase flow meter and could cause error in recognizing the flow pattern and determining void fraction. In this work, we proposed a methodology based on combination of multi-beam gamma ray attenuation and dual modality densitometry techniques using RBF neural network in order to recognize the flow regime and determine the void fraction in gas-liquid two phase flows independent of the liquid phase changes. The proposed system is consisted of one 137 Cs source, two transmission detectors and one scattering detector. The registered counts in two transmission detectors were used as the inputs of one primary Radial Basis Function (RBF) neural network for recognizing the flow regime independent of liquid phase density. Then, after flow regime identification, three RBF neural networks were utilized for determining the void fraction independent of liquid phase density. Registered count in scattering detector and first transmission detector were used as the inputs of these three RBF neural networks. Using this simple methodology, all the flow patterns were correctly recognized and the void fraction was predicted independent of liquid phase density with mean relative error (MRE) of less than 3.28%. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kedzierski, Michal; Fryskowska, Anna
2014-07-07
Visualization techniques have been greatly developed in the past few years. Three-dimensional models based on satellite and aerial imagery are now being enhanced by models generated using Aerial Laser Scanning (ALS) data. The most modern of such scanning systems have the ability to acquire over 50 points per square meter and to register a multiple echo, which allows the reconstruction of the terrain together with the terrain cover. However, ALS data accuracy is less than 10 cm and the data is often incomplete: there is no information about ground level (in most scanning systems), and often around the facade or structures which have been covered by other structures. However, Terrestrial Laser Scanning (TLS) not only acquires higher accuracy data (1-5 cm) but is also capable of registering those elements which are incomplete or not visible using ALS methods (facades, complicated structures, interiors, etc.). Therefore, to generate a complete 3D model of a building in high Level of Details, integration of TLS and ALS data is necessary. This paper presents the wavelet-based method of processing and integrating data from ALS and TLS. Methods of choosing tie points to combine point clouds in different datum will be analyzed.
Barrientos, Christian; Holmberg, Mats
2018-05-01
The aim of this study was to describe the care of patients assessed as not in need of emergency ambulance care, from Registered Nurse's lived experiences. Non-emergency patients in need of ambulance care are described as vulnerable and patients in ambulance care have earlier been found to be dependent on the Registered Nurse. However, little is known about the care of non-emergency patients in the ambulance setting, from the perspective of Registered Nurses. A reflective lifeworld research design was chosen. Five Registered Nurses with experience of ambulance care were individually interviewed. The result reveals the essence of the phenomenon as a desire to provide good care in an on-going struggle between one's own and others' expectations. Three meaning constituents emerged in the description; Being in a struggle between different expectations, Being in a questioned professional role, and Being in lack of support and formal directives. Registered Nurses' care for patients assessed as not in need of emergency ambulance care, is a complex struggle between different expectations. This may be related to the encounter between the nurse's and the patient's lifeworld. Copyright © 2018 Elsevier Ltd. All rights reserved.
Empowering aged care nurses to deliver person-centred care: Enabling nurses to shine.
Marriott-Statham, Kelly; Mackay, Maria; Brennan, Ngaire; Mackay, Jacinta
2018-05-23
In this paper, the authors will describe the journey of registered nurses across a series of workshops as part of a research project that was undertaken in a regional aged care service in New South Wales, Australia. The aim of the project was to empower the participant registered nurses to positively influence the health care workplace culture within the residential care home by raising consciousness about their own practice. Registered nurses were actively involved in this reconnaissance phase of a participatory action research project through practice development principles and methods. Registered nurses determined the content and the outcomes of the overall program. The researchers evaluated the impact of a series of workshops, designed to develop skills and knowledge using nominal group technique. Results revealed registered nurses perceived they were empowered to flourish, and developed an understanding of the uniqueness of their role. A shared understanding of the role of the registered nurse in the aged care setting was fundamental in enabling them to feel empowered to lead their team and contribute positively to the workplace culture. Overall, the outcomes of this project have positively impacted workplace culture. Copyright © 2018. Published by Elsevier Ltd.
Physical restraint: perceptions of nurse managers, registered nurses and healthcare assistants.
Leahy-Warren, P; Varghese, V; Day, M R; Curtin, M
2018-02-09
To examine the perceptions of nurse managers, registered nurses and healthcare assistants of physical restraint use on older people in a long-term care setting in the Republic of Ireland. The use of physical restraint, although controversial, persists in long-term care settings, despite recommendations for restraint-free environments. Perception and attitude of staff can influence use of physical restraint. A descriptive cross-sectional design was used. A total of 250 nursing and healthcare assistant staff were recruited. A questionnaire incorporating demographics and the Perceptions of Restraint Use Questionnaire was used. Descriptive and inferential statistical analyses were conducted. Mean age of respondents (n = 156) was 41 years, and the majority were female. Overall, a low level of importance was attached to the use of restraint. Nurse managers and registered nurses compared favourably with healthcare assistants who attached a higher importance to use of restraint. Across all three staff groups, greatest importance was attached to the use of physical restraint for reducing falls, followed by prevention of treatment interference. Restraint was least favoured as a means of impairment management. Education was not an explanatory factor in perceived importance of physical restraint use. Nurse managers and registered nurses are unlikely to use physical restraint. However, there is concern regarding perception of healthcare assistants on use of restraint. Results from this study compare favourably with those in countries that have no policy on physical restraint use. Educational programmes alone are insufficient to address use of physical restraint. Attention to skill mix with adequate support for healthcare assistants in long-term care settings is recommended. © 2018 International Council of Nurses.
Context Switching with Multiple Register Windows: A RISC Performance Study
NASA Technical Reports Server (NTRS)
Konsek, Marion B.; Reed, Daniel A.; Watcharawittayakul, Wittaya
1987-01-01
Although previous studies have shown that a large file of overlapping register windows can greatly reduce procedure call/return overhead, the effects of register windows in a multiprogramming environment are poorly understood. This paper investigates the performance of multiprogrammed, reduced instruction set computers (RISCs) as a function of window management strategy. Using an analytic model that reflects context switch and procedure call overheads, we analyze the performance of simple, linearly self-recursive programs. For more complex programs, we present the results of a simulation study. These studies show that a simple strategy that saves all windows prior to a context switch, but restores only a single window following a context switch, performs near optimally.
El Hussein, Mohamed; Hirst, Sandra
2016-02-01
The aim of this study was to construct a grounded theory that explains the clinical reasoning processes that registered nurses use to recognize delirium in older adults in acute care hospitals. Delirium is under-recognized in acute hospital settings, this may stem from underdeveloped clinical reasoning processes. Little is known about registered nurses' (RNs) clinical reasoning processes in complex situations such as delirium recognition. A grounded theory approach was used to analyse interview data about the clinical reasoning processes of RNs in acute hospital settings. Seventeen RNs were recruited. Concurrent data collection and comparative analysis and theoretical sampling were conducted in 2013-2014. The core category to emerge from the data was 'chasing the mirage', which describes RNs' clinical reasoning processes to recognize delirium during their interaction with older adults. Understanding the reasoning that contributes to delirium under-recognition provides a strategy by which, this problem can be brought to the forefront of RNs' awareness and intervention. Delirium recognition will contribute to quality care for older adults. © 2015 John Wiley & Sons Ltd.
van Gorp, D A M; van der Klink, J J L; Abma, F I; Jongen, P J; van Lieshout, I; Arnoldus, E P J; Beenakker, E A C; Bos, H M; van Eijk, J J J; Fermont, J; Frequin, S T F M; de Gans, K; Hengstman, G J D; Hupperts, R M M; Mostert, J P; Pop, P H M; Verhagen, W I M; Zemel, D; Heerings, M A P; Reneman, M F; Middelkoop, H A M; Visser, L H; van der Hiele, K
2018-06-01
The aim of this study was to examine whether work capabilities differ between workers with Multiple Sclerosis (MS) and workers from the general population. The second aim was to investigate whether the capability set was related to work and health outcomes. A total of 163 workers with MS from the MS@Work study and 163 workers from the general population were matched for gender, age, educational level and working hours. All participants completed online questionnaires on demographics, health and work functioning. The Capability Set for Work Questionnaire was used to explore whether a set of seven work values is considered valuable (A), is enabled in the work context (B), and can be achieved by the individual (C). When all three criteria are met a work value can be considered part of the individual's 'capability set'. Group differences and relationships with work and health outcomes were examined. Despite lower physical work functioning (U = 4250, p = 0.001), lower work ability (U = 10591, p = 0.006) and worse self-reported health (U = 9091, p ≤ 0.001) workers with MS had a larger capability set (U = 9649, p ≤ 0.001) than the general population. In workers with MS, a larger capability set was associated with better flexible work functioning (r = 0.30), work ability (r = 0.25), self-rated health (r = 0.25); and with less absenteeism (r = - 0.26), presenteeism (r = - 0.31), cognitive/neuropsychiatric impairment (r = - 0.35), depression (r = - 0.43), anxiety (r = - 0.31) and fatigue (r = - 0.34). Workers with MS have a larger capability set than workers from the general population. In workers with MS a larger capability set was associated with better work and health outcomes. This observational study is registered under NL43098.008.12: 'Voorspellers van arbeidsparticipatie bij mensen met relapsing-remitting Multiple Sclerose'. The study is registered at the Dutch CCMO register ( https://www.toetsingonline.nl ). This study is approved by the METC Brabant, 12 February 2014. First participants are enrolled 1 st of March 2014.
Hardware support for software controlled fast multiplexing of performance counters
Salapura, Valentina; Wisniewski, Robert W
2013-10-01
Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.
Hardware support for software controlled fast multiplexing of performance counters
Salapura, Valentina; Wisniewski, Robert W.
2013-01-01
Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.
NASA Astrophysics Data System (ADS)
Liu, Tianqi; Yang, Zhenlei; Guo, Jinlong; Du, Guanghua; Tong, Teng; Wang, Xiaohui; Su, Hong; Liu, Wenjing; Liu, Jiande; Wang, Bin; Ye, Bing; Liu, Jie
2017-08-01
The heavy-ion imaging of single event upset (SEU) in a flash-based field programmable gate array (FPGA) device was carried out for the first time at Heavy Ion Research Facility in Lanzhou (HIRFL). The three shift register chains with separated input and output configurations in device under test (DUT) were used to identify the corresponding logical area rapidly once an upset occurred. The logic units in DUT were partly configured in order to distinguish the registers in SEU images. Based on the above settings, the partial architecture of shift register chains in DUT was imaged by employing the microbeam of 86Kr ion with energy of 25 MeV/u in air. The results showed that the physical distribution of registers in DUT had a high consistency with its logical arrangement by comparing SEU image with logic configuration in scanned area.
NASA Astrophysics Data System (ADS)
Macmannis, K. R.; Hawley, R. J.
2013-12-01
The mechanisms controlling stability on small streams in steep settings are not well documented but have many implications related to stream integrity and water quality. For example, channel instability on first and second order streams is a potential source of sediment in regulated areas with Total Maximum Daily Loads (TMDLs) on water bodies that are impaired for sedimentation, such as the Chesapeake Bay. Management strategies that preserve stream integrity and protect channel stability are critical to communities that may otherwise require large capital investments to meet TMDLs and other water quality criteria. To contribute to an improved understanding of ephemeral step-pool systems, we collected detailed hydrogeomorphic data on 4 steep (0.06 - 0.12 meter/meter) headwater streams draining to lower relief alluvial valleys in Spencer County, Kentucky, USA. The step-pool streams (mean step height of 0.47 meter, mean step spacing of 4 meters) drained small undeveloped catchments dominated by early successional forest. Data collection for each of the 4 streams included 2 to 3 cross section surveys, bed material particle counts at cross section locations, and profile surveys ranging from approximately 125 to 225 meters in length. All survey data was systematically processed to understand geometric parameters such as cross sectional area, depth, and top width; bed material gradations; and detailed profile measurements such as slope, pool and riffle lengths, pool spacing, pool depth, step height, and step length. We documented the location, frequency, and type of step-forming materials (i.e., large woody debris (LWD), rock, and tree roots), compiling a database of approximately 130 total steps. Lastly, we recorded a detailed tree assessment of all trees located within 2 meters of the top of bank, detailing the species of tree, trunk diameter, and approximate distance from the top of bank. Analysis of geometric parameters illustrated correlations between channel characteristics (e.g., step height was positively correlated to slope while pool spacing was inversely correlated to slope). Most importantly, we assessed the step-forming materials with respect to channel stability. LWD has been widely documented as an important component of geomorphic stability and habitat diversity across many settings; however, our research highlights the importance of roots in providing bed stability in steep, first and second-order ephemeral streams, as 40 percent of the steps in these step-pool systems were controlled by tree roots. Similar to the key member in naturally-occurring log jams, lateral tree roots frequently served as the anchor for channel steps that were often supplemented by rocks or LWD. Assessment of the trees throughout the riparian zone suggested average tree densities of 0.30 trees/square meter or 0.40 trees/meter could provide adequate riparian zone coverage to promote channel stability. These results have implications to land use planning and stormwater management. For example, on developments draining to step-pool systems, maintaining the integrity of the riparian zone would seem to be as important as ensuring hydrologic mimicry if channel integrity is to be preserved.
Registered nurses' use of research findings in the care of older people.
Boström, Anne-Marie; Kajermo, Kerstin Nilsson; Nordström, Gun; Wallin, Lars
2009-05-01
To describe registered nurses' reported use of research in the care of older people and to examine associations between research use and factors related to the elements: the communication channels, the adopter and the social system. Research use among registered nurses working in hospital settings has been reported in many studies. Few studies, however, have explored the use of research among registered nurses working in the care of older people. A cross-sectional survey. In eight municipalities, all registered nurses (n = 210) working in older people care were invited to participate (response rate 67%). The Research Utilisation Questionnaire was adopted. Questions concerning the work organisation and research-related resources were sent to the Community Chief Nurse at each municipality. Descriptive statistics and logistic regression were applied. The registered nurses reported a relatively low use of research findings in daily practice, despite reporting a positive attitude to research. The registered nurses reported lack of access to research reports at the work place and that they had little support from unit managers and colleagues. Registered nurses working in municipalities with access to research-related resources reported more use of research than registered nurses without resources. The factors 'Access to research findings at work place', 'Positive attitudes to research' and 'Nursing programme at university level' were significantly associated with research use. There is a great potential to increase registered nurses' use of research findings in the care of older people. Factors which were linked to the communication channels and the adopter were associated with research use. Strategies to enhance research use should focus on access to and adequate training in using information sources, increased knowledge on research methodology and nursing science and a supportive organisation.
Rosvall, Annica; Carlson, Elisabeth
2017-12-01
To describe how registered nurses having undergone a web-based learning activity perceive their self-efficacy and competence to support patients with smoking cessation in connection with surgery. Smoking cessation in connection with surgery reduces postoperative complications, and the support patients get from registered nurses may be important in helping them become smoke-free in connection with their surgery. Therefore, registered nurses are in need of enhanced understanding about which kind of counselling is the most effective for smoking cessation. Educating large groups of registered nurses in a digital environment appears to be a flexible and cost-effective way. A convergent mixed-method design with data collection was done using questionnaires (n = 47) and semistructured interviews (n = 11). Inclusion criteria were registered nurses in surgical wards. The samples were nonprobability and modified nested. Descriptive statistics and content analysis were used for data analysis. After completing the web-based learning activity, the registered nurses perception was that of good self-efficacy and increased competence in supporting patients with smoking cessation in connection with surgery. They improved their understanding of how to talk about smoking cessation with patients in dialogue using open-ended questions. Nevertheless, the registered nurses requested opportunities for dialogue and interaction with colleagues or topic experts. The results indicate that registered nurses can enhance their competence in supporting patients to embrace smoking cessation by learning in a digital environment. Self-efficacy and understanding of the topic seems to motivate registered nurses to counsel patients about smoking cessation. Findings from this study will be of particular interest to educators in healthcare settings who can devise further development of web-based learning activities. © 2017 John Wiley & Sons Ltd.
NURSE STAFFING AND RENAL ANAEMIA OUTCOMES IN HAEMODIALYSIS CARE.
Erlingmark, Julia; Hedström, Mariann; Lindberg, Magnus
2016-09-01
Current trends in renal anaemia management place greater emphasis, and thus increased workload, on the role of the nurse in haemodialysis settings. However, there is little evidence that demonstrates the relationship between nurse staffing and patient outcomes. To describe nurse staffing in haemodialysis settings, its relationship with target levels of renal anaemia management and to describe target level achievement for different ways of organising anaemia management. Cross-sectional audit. Forty (out of 78) haemodialysis centres in Sweden reported quality assurance data. The numbers of bedside registered nurses, licensed nurse assistants and patients undergoing haemodialysis during a predefined morning shift; type of anaemia management and achieved target levels of anaemia management. The mean patient:registered nurse ratio was 2.4 and the mean patient:nurse assistant ratio was 12.8. There were no significant relationships between registered nurse staffing and target level achievement. On average, 45.6% of the patients had haemoglobin within the target levels at centres applying nurse-driven anaemia management, compared with 47.3% at physician-driven centres. These cross-sectional data suggest that renal anaemia outcomes are unrelated to the patient:registered nurse ratio. There is, however, room for improvement in renal anaemia management in the units included in this study, particularly the achievement of target levels of haemoglobin and transferrin saturation. © 2016 European Dialysis and Transplant Nurses Association/European Renal Care Association.
Excessive exposure of sick neonates to sound during transport
Buckland, L; Austin, N; Jackson, A; Inder, T
2003-01-01
Objective: To determine the levels of sound to which infants are exposed during routine transport by ambulance, aircraft, and helicopter. Design: Sound levels during 38 consecutive journeys from a regional level III neonatal intensive care unit were recorded using a calibrated data logging sound meter (Quest 2900). The meter was set to record "A" weighted slow response integrated sound levels, which emulates the response of the human ear, and "C" weighted response sound levels as a measure of total sound level exposure for all frequencies. The information was downloaded to a computer using MS HyperTerminal. The resulting data were stored, and a graphical profile was generated for each journey using SigmaPlot software. Setting: Eight journeys involved ambulance transport on country roads, 24 involved fixed wing aircraft, and four were by helicopter. Main outcome measures: Relations between decibel levels and events or changes in transport mode were established by correlating the time logged on the sound meter with the standard transport documentation sheet. Results: The highest sound levels were recorded during air transport. However, mean sound levels for all modes of transport exceeded the recommended levels for neonatal intensive care. The maximum sound levels recorded were extremely high at greater than 80 dB in the "A" weighted hearing range and greater than 120 dB in the total frequency range. Conclusions: This study raises major concerns about the excessive exposure of the sick newborn to sound during transportation. PMID:14602701
Sound Standards for Schools "Unsound."
ERIC Educational Resources Information Center
Davis, Don
2002-01-01
Criticizes new classroom sound standard proposed by the American National Standards Institute that sets maximum background sound level at 35 decibels (described as "a whisper at 2 meters"). Argues that new standard is too costly for schools to implement, is not recommended by the medical community, and cannot be achieved by construction…
The International System of Units and Its Use in Geography and Related Disciplines.
ERIC Educational Resources Information Center
Lee, Jeffrey A.
1995-01-01
Introduces college level geography students to the International System of Units (SI), a standardized set of units used in science, engineering, and commerce. Identifies the SI base units as meter, kilogram, second, kelvin, ampere, mole, and candela. Includes geographically relevant examples of each. (MJP)
49 CFR 210.31 - Operation standards (stationary locomotives at 30 meters).
Code of Federal Regulations, 2010 CFR
2010-10-01
... stationary locomotives at load cells: (1) Each noise emission test shall begin after the engine of the locomotive has attained the normal cooling water operating temperature as prescribed by the locomotive manufacturer. (2) Noise emission testing in idle or maximum throttle setting shall start after a 40 second...
Relations Among Systems of Electromagnetic Equations
ERIC Educational Resources Information Center
page, Chester H.
1970-01-01
Contends that the equations of electromagnetism, whether in rationalized or non-rationalized form, express an invariant set of physical relationships. The relationships among corresponding symbols are given and applied to precise statements about the relation between the oersted and the amphere per meter, the abampere and the ampere, etc.…
Facilitating mental health research for patients, clinicians and researchers: a mixed-method study
Robotham, D; Waterman, S; Oduola, S; Papoulias, C; Craig, T; Wykes, T
2016-01-01
Objectives Research registers using Consent for Contact (C4C) can facilitate recruitment into mental health research studies, allowing investigators to contact patients based on clinical records information. We investigated whether such a register was useful for mental health research, seeking the perspectives of patients and research investigators. Setting and design In 2012, a C4C register was developed in a large secondary mental health provider within the UK; almost 9000 patients have joined. This mixed-method study audited the effectiveness of the register. Participants A ‘mystery shopper’ exercise was conducted, and patients (n=21) were recruited to ask clinicians about the availability of research opportunities. Structured interviews were conducted with patients (n=52) about their experiences of being on the register. Similar interviews were conducted with 18 investigators from 19 studies, who had attempted to use the register to recruit participants. Outcome measures The impact of C4C on study recruitment, and whether it helped patients learn about research. Results So far, the register has provided 928 individuals with 1085 research opportunities (in 60% of cases, the individual agreed to participate in the study). Clinicians were willing to link patients to research opportunities, but often lacked information about studies. For patients, the register provided opportunities which they may not otherwise have; 27 of 52 had participated in studies since joining the register (18 participating for the first time). Most investigators used the register to supplement recruitment to their studies, but described problems in prescreening potential participants from a clinical record for complex studies. Conclusions Although the register helped investigators recruit for studies, and provided patients with research opportunities, clinicians' input is still useful for identifying suitable participants. C4C registers should be adapted to provide clinicians with automatically updated information on local studies allowing them to match patients on their caseload with active studies. PMID:27503859
Janoudi, Abdul; Poff, Kenneth L.
1990-01-01
The relationship between the amount of light and the amount of response for any photobiological process can be based on the number of incident quanta per unit time (fluence rate-response) or on the number of incident quanta during a given period of irradiation (fluence-response). Fluence-response and fluence rate-response relationships have been measured for second positive phototropism by seedlings of Arabidopsis thaliana. The fluence-response relationships exhibit a single limiting threshold at about 0.01 micromole per square meter when measured at fluence rates from 2.4 × 10−5 to 6.5 × 10−3 micromoles per square meter per second. The threshold values in the fluence rateresponse curves decrease with increasing time of irradiation, but show a common fluence threshold at about 0.01 micromole per square meter. These thresholds are the same as the threshold of about 0.01 micromole per square meter measured for first positive phototropism. Based on these data, it is suggested that second positive curvature has a threshold in time of about 10 minutes. Moreover, if the times of irradiation exceed the time threshold, there is a single limiting fluence threshold at about 0.01 micromole per square meter. Thus, the limiting fluence threshold for second positive phototropism is the same as the fluence threshold for first positive phototropism. Based on these data, we suggest that this common fluence threshold for first positive and second positive phototropism is set by a single photoreceptor pigment system. PMID:11537470
Dairy manure nutrient analysis using quick tests.
Singh, A; Bicudo, J R
2005-05-01
Rapid on-farm assessment of manure nutrient content can be achieved with the use of quick tests. These tests can be used to indirectly measure the nutrient content in animal slurries immediately before manure is applied on agricultural fields. The objective of this study was to assess the reliability of hydrometers, electrical conductivity meter and pens, and Agros N meter against standard laboratory methods. Manure samples were collected from 34 dairy farms in the Mammoth Cave area in central Kentucky. Regression equations were developed for combined and individual counties located In the area (Barren, Hart and Monroe). Our results indicated that accuracy in nutrient estimation could be improved if separate linear regressions were developed for farms with similar facilities in a county. Direct hydrometer estimates of total nitrogen were among the most accurate when separate regression equations were developed for each county (R2 = 0.61, 0.93, and 0.74 for Barren, Hart and Monroe county, respectively). Reasonably accurate estimates (R2 > 0.70) were also obtained for total nitrogen and total phosphorus using hydrometers, either by relating specific gravity to nutrient content or to total solids content. Estimation of ammoniacal nitrogen with Agros N meter and electrical conductivity meter/pens correlated well with standard laboratory determinations, especially while using the individual data sets from Hart County (R2 = 0.70 to 0.87). This study indicates that the use of quick test calibration equations developed for a small area or region where farms are similar in terms of manure handling and management, housing, and feed ration are more appropriate than using "universal" equations usually developed with combined data sets. Accuracy is expected to improve if individual farms develop their own calibration curves. Nevertheless, we suggest confidence intervals always be specified for nutrients estimated through quick testing for any specific region, county, or farm.
Improving Station Performance by Building Isolation Walls in the Tunnel
NASA Astrophysics Data System (ADS)
Jia, Yan; Horn, Nikolaus; Leohardt, Roman
2014-05-01
Conrad Observatory is situated far away from roads and industrial areas on the Trafelberg in Lower Austria. At the end of the seismic tunnel, the main seismic instrument of the Observatory with a station code CONA is located. This station is one of the most important seismic stations in the Austrian Seismic Network (network code OE). The seismic observatory consists of a 145m long gallery and an underground laboratory building with several working areas. About 25 meters away from the station CONA, six temporary seismic stations were implemented for research purposes. Two of them were installed with the same equipment as CONA, while the remaining four stations were set up with digitizers having lower noise and higher resolution (Q330HR) and sensors with the same type (STS-2). In order to prevent possible disturbances by air pressure and temperature fluctuation, three walls were built inside of the tunnel. The first wall is located ca 63 meters from the tunnel entrance, while a set of double walls with a distance of 1.5 meters is placed about 53 meters from the first isolation wall but between the station CONA and the six temporary stations. To assess impact of the isolation walls on noise reduction and detection performance, investigations are conducted in two steps. The first study is carried out by comparing the noise level and detection performance between the station CONA behind the double walls and the stations in front of the double walls for verifying the noise isolation by the double walls. To evaluate the effect of the single wall, station noise level and detection performance were studied by comparing the results before and after the installation of the wall. Results and discussions will be presented. Additional experiment is conducted by filling insulation material inside of the aluminium boxes of the sensors (above and around the sensors). This should help us to determine an optimal insulation of the sensors with respect to pressure and temperature fluctuations.
Van Hemelrijck, Mieke; Wigertz, Annette; Sandin, Fredrik; Garmo, Hans; Hellström, Karin; Fransson, Per; Widmark, Anders; Lambe, Mats; Adolfsson, Jan; Varenhorst, Eberhard; Johansson, Jan-Erik; Stattin, Pär
2013-08-01
In 1987, the first Regional Prostate Cancer Register was set up in the South-East health-care region of Sweden. Other health-care regions joined and since 1998 virtually all prostate cancer (PCa) cases are registered in the National Prostate Cancer Register (NPCR) of Sweden to provide data for quality assurance, bench marking and clinical research. NPCR includes data on tumour stage, Gleason score, serum level of prostate-specific antigen (PSA) and primary treatment. In 2008, the NPCR was linked to a number of other population-based registers by use of the personal identity number. This database named Prostate Cancer data Base Sweden (PCBaSe) has now been extended with more cases, longer follow-up and a selection of two control series of men free of PCa at the time of sampling, as well as information on brothers of men diagnosed with PCa, resulting in PCBaSe 2.0. This extension allows for studies with case-control, cohort or longitudinal case-only design on aetiological factors, pharmaceutical prescriptions and assessment of long-term outcomes. The NPCR covers >96% of all incident PCa cases registered by the Swedish Cancer Register, which has an underreporting of <3.7%. The NPCR is used to assess trends in incidence, treatment and outcome of men with PCa. Since the national registers linked to PCBaSe are complete, studies from PCBaSe 2.0 are truly population based.
Reportable Quantities Federal Register Notices
Comprehensive Environmental Response, Compensation and Liability Act regulation designates specific substances as hazardous; identifies the quantity of substances which, when released, requires notification; and sets forth the notification requirements.
NASA Astrophysics Data System (ADS)
Naylor, S.; Gustin, A. R.; Ellett, K. M.
2012-12-01
Weather stations that collect reliable, sustained meteorological data sets are becoming more widely distributed because of advances in both instrumentation and data server technology. However, sites collecting soil moisture and soil temperature data remain sparse with even fewer locations where complete meteorological data are collected in conjunction with soil data. Thanks to the advent of sensors that collect continuous in-situ thermal properties data for soils, we have gone a step further and incorporated thermal properties measurements as part of hydrologic instrument arrays in central and northern Indiana. The coupled approach provides insights into the variability of soil thermal conductivity and diffusivity attributable to geologic and climatological controls for various hydrogeologic settings. These data are collected to facilitate the optimization of ground-source heat pumps (GSHPs) in the glaciated Midwest by establishing publicly available data that can be used to parameterize system design models. A network of six monitoring sites was developed in Indiana. Sensors that determine thermal conductivity and diffusivity using radial differential temperature measurements around a heating wire were installed at 1.2 meters below ground surface— a typical depth for horizontal GSHP systems. Each site also includes standard meteorological sensors for calculating reference evapotranspiration following the methods by the Food and Agriculture Organization (FAO) of the United Nations. Vadose zone instrumentation includes time domain reflectometry soil-moisture and temperature sensors installed at 0.3-meter depth intervals down to a 1.8-meter depth, in addition to matric potential sensors at 0.15, 0.3, 0.6, and 1.2 meters. Cores collected at 0.3-meter intervals were analyzed in a laboratory for grain size distribution, bulk density, thermal conductivity, and thermal diffusivity. Our work includes developing methods for calibrating thermal properties sensors based on known standards and comparing measurements from transient line heat source devices. Transform equations have been developed to correct in-situ measurements of thermal conductivity and comparing these results with soil moisture data indicates that thermal conductivity can increase by as much as 25 percent during wetting front propagation. Thermal dryout curves have also been modeled based on laboratory conductivity data collected from core samples to verify field measurements, and alternatively, temperature profile data are used to calibrate near-surface temperature gradient models. We compare data collected across various spatial scales to assess the potential for upscaling near-surface thermal regimes based on available soils data. A long-term goal of the monitoring effort is to establish continuous data sets that determine the effect of climate variability on soil thermal properties such that expected ranges in thermal conductivity can be used to determine optimal ground-coupling loop lengths for GSHP systems.
Ash bed level control system for a fixed-bed coal gasifier
Fasching, George E.; Rotunda, John R.
1984-01-01
An ash level control system is provided which incorporates an ash level meter to automatically control the ash bed level of a coal gasifier at a selected level. The ash level signal from the ash level meter is updated during each cycle that a bed stirrer travels up and down through the extent of the ash bed level. The ash level signal is derived from temperature measurements made by thermocouples carried by the stirrer as it passes through the ash bed and into the fire zone immediately above the ash bed. The level signal is compared with selected threshold level signal to determine if the ash level is above or below the selected level once each stirrer cycle. A first counter is either incremented or decremented accordingly. The registered count of the first counter is preset in a down counter once each cycle and the preset count is counted down at a selected clock rate. A grate drive is activated to rotate a grate assembly supporting the ash bed for a period equal to the count down period to maintain the selected ash bed level. In order to avoid grate binding, the controller provides a short base operating duration time each stirrer cycle. If the ash bed level drops below a selected low level or exceeds a selected high level, means are provided to notify the operator.
Geometric correction and digital elevation extraction using multiple MTI datasets
Mercier, Jeffrey A.; Schowengerdt, Robert A.; Storey, James C.; Smith, Jody L.
2007-01-01
Digital Elevation Models (DEMs) are traditionally acquired from a stereo pair of aerial photographs sequentially captured by an airborne metric camera. Standard DEM extraction techniques can be naturally extended to satellite imagery, but the particular characteristics of satellite imaging can cause difficulties. The spacecraft ephemeris with respect to the ground site during image collects is the most important factor in the elevation extraction process. When the angle of separation between the stereo images is small, the extraction process typically produces measurements with low accuracy, while a large angle of separation can cause an excessive number of erroneous points in the DEM from occlusion of ground areas. The use of three or more images registered to the same ground area can potentially reduce these problems and improve the accuracy of the extracted DEM. The pointing capability of some sensors, such as the Multispectral Thermal Imager (MTI), allows for multiple collects of the same area from different perspectives. This functionality of MTI makes it a good candidate for the implementation of a DEM extraction algorithm using multiple images for improved accuracy. Evaluation of this capability and development of algorithms to geometrically model the MTI sensor and extract DEMs from multi-look MTI imagery are described in this paper. An RMS elevation error of 6.3-meters is achieved using 11 ground test points, while the MTI band has a 5-meter ground sample distance.
Wang, Xiaohui; Chontawan, Ratanawadee; Nantsupawat, Raymoul
2012-02-01
The aim of this study was to describe the relationship between the transformational leadership of nurse managers and job satisfaction among clinical Registered Nurses at a tertiary care hospital in China. The healthcare system is changing rapidly. Research in Western countries has shown that transformational leadership affects job satisfaction. However, very little research related to this subject has been conducted in healthcare settings in China. The sample consisted of 238 nurses who work at a tertiary care hospital in China. Data were collected from April to August 2006. Research instruments included a demographic data form, a Leadership Practice Inventory and a Job Satisfaction Scale for clinical registered nurses. Both the transformational leadership of nurse managers and job satisfaction among clinical Registered Nurses were at a moderate level. There was a statistically significant positive correlation between the transformational leadership of nurse managers and job satisfaction (r = 0·556, P < 0·001). The findings indicate that the transformational leadership of nurse managers could have an effect on the job satisfaction of clinical Registered Nurses. © 2011 Blackwell Publishing Ltd.
77 FR 18307 - Update to the January 6, 2012, Federal Register
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-27
... to announce that a Presidential $1 Four-Coin Set, priced at $9.95, will be offered instead of the $1... follows: Retail Product price Presidential $1 Four-Coin Set $9.95 Presidential $1 Coin & First Spouse... FURTHER INFORMATION CONTACT: B. B. Craig, Associate Director for Sales and Marketing, United States Mint...
Diabetes Management in the School Setting. Position Statement. Revised
ERIC Educational Resources Information Center
Wright, Janet B.; Easterling, Traci; Hardy, Alicen
2017-01-01
It is the position of the National Association of School Nurses (NASN) that the registered professional school nurse (hereinafter referred to as school nurse) is the school staff member who has the knowledge, skills, and statutory authority to fully meet the healthcare needs of students with diabetes in the school setting. Diabetes management in…
Diabetes Management in the School Setting. Position Statement
ERIC Educational Resources Information Center
Butler, Sarah; Fekaris, Nina; Pontius, Deborah; Zacharski, Susan
2012-01-01
It is the position of the National Association of School Nurses that the registered professional school nurse (hereinafter referred to as school nurse) is the only school staff member who has the skills, knowledge base, and statutory authority to fully meet the healthcare needs of students with diabetes in the school setting. Diabetes management…
NASA Astrophysics Data System (ADS)
Salamuniccar, G.; Loncaric, S.
2008-03-01
The Catalogue from our previous work was merged with the date of Barlow, Rodionova, Boyce, and Kuzmin. The resulting ground truth catalogue with 57,633 craters was registered, using MOLA data, with THEMIS-DIR, MDIM, and MOC data-sets.
Examination of the Use of Healing Touch by Registered Nurses in the Acute Care Setting.
Anderson, Joel G; Friesen, Mary Ann; Swengros, Diane; Herbst, Anna; Mangione, Lucrezia
2017-03-01
Acute care nursing is currently undergoing unprecedented change, with health systems becoming more open to nonpharmacological approaches to patient care. Healing Touch (HT) may be a valuable intervention for acute care patients. Research has shown that HT helps both the patient and the caregiver; however, no study to date has examined the impact that the education of nurses in and their use of HT have on daily care delivery in the acute care setting. The purpose of the current qualitative study was to examine the use of HT by registered nurses in the acute care setting during their delivery of patient care, as well as the impact of education in and use of HT on the nurses themselves. Five themes were identified: (1) use of HT techniques, processes, and sequence; (2) outcomes related to HT; (3) integration of HT into acute care nursing practice; (4) perceptions of HT, from skepticism to openness; and (5) transformation through HT. Education in HT and delivery of this modality by nurses in the acute care setting provide nurses with a transformative tool to improve patient outcomes.
Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burke, Thomas; Willem, Henry; Ni, Chun Chun
2014-12-12
As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance ofmore » PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States. LBNL performed its field-metering study from mid-April to late October 2014. The study, which monitored 19 sites in the Northeastern United States (4 in upstate New York and 15 near Philadelphia), collected real-time data on PAC energy consumption along with information regarding housing characteristics, consumer behavior, and environmental conditions that were expected to affect PAC performance. Given the limited number of test sites, this study was not intended to be statistically representative of PAC users in the United States but rather to understand the system response to the cooling demand and to some extent, the operating hours of the studied units. Specifically, the primary objectives of the field-metering study were to (1) expand knowledge of the installation, energy consumption profiles, consumer patterns of use, and environmental parameters related to PAC use; (2) develop distributions of hours of PAC operation for three operating modes: standby, 1 fan-only, and cooling; and (3) describe how individual consumers’ selection of PAC capacity, the area of the space to be cooled, the temperature set point, and environmental conditions affect energy use. Beginning to understand the energy consumption of PACs operating in American homes and commercial settings will help develop a more accurate energy use profile that characterizes relevant variables. This report on LBNL’s field-metering study of PAC energy use describes: a general definition of a PAC and how it operates (section 2); current practices and sources of data for estimating PAC energy use (section 3); the process LBNL used to select field-metering sites, along with characteristics of the sites and the PACs studied (section 4); data collection methods and instrumentation (section 5); analysis methods (section 6); results and discussion (section 7); and conclusions (section 8).« less
Mapping health outcome measures from a stroke registry to EQ-5D weights.
Ghatnekar, Ola; Eriksson, Marie; Glader, Eva-Lotta
2013-03-07
To map health outcome related variables from a national register, not part of any validated instrument, with EQ-5D weights among stroke patients. We used two cross-sectional data sets including patient characteristics, outcome variables and EQ-5D weights from the national Swedish stroke register. Three regression techniques were used on the estimation set (n=272): ordinary least squares (OLS), Tobit, and censored least absolute deviation (CLAD). The regression coefficients for "dressing", "toileting", "mobility", "mood", "general health" and "proxy-responders" were applied to the validation set (n=272), and the performance was analysed with mean absolute error (MAE) and mean square error (MSE). The number of statistically significant coefficients varied by model, but all models generated consistent coefficients in terms of sign. Mean utility was underestimated in all models (least in OLS) and with lower variation (least in OLS) compared to the observed. The maximum attainable EQ-5D weight ranged from 0.90 (OLS) to 1.00 (Tobit and CLAD). Health states with utility weights <0.5 had greater errors than those with weights ≥ 0.5 (P<0.01). This study indicates that it is possible to map non-validated health outcome measures from a stroke register into preference-based utilities to study the development of stroke care over time, and to compare with other conditions in terms of utility.
NASA Technical Reports Server (NTRS)
Jackson, Karen E.; Fasanella, Edwin L.; Littell, Justin D.
2017-01-01
This paper describes the development of input properties for a continuum damage mechanics based material model, Mat 58, within LS-DYNA(Registered Trademark) to simulate the response of a graphite-Kevlar(Registered Trademark) hybrid plain weave fabric. A limited set of material characterization tests were performed on the hybrid graphite-Kevlar(Registered Trademark) fabric. Simple finite element models were executed in LS-DYNA(Registered Trademark) to simulate the material characterization tests and to verify the Mat 58 material model. Once verified, the Mat 58 model was used in finite element models of two composite energy absorbers: a conical-shaped design, designated the "conusoid," fabricated of four layers of hybrid graphite-Kevlar(Registered Trademark) fabric; and, a sinusoidal-shaped foam sandwich design, designated the "sinusoid," fabricated of the same hybrid fabric face sheets with a foam core. Dynamic crush tests were performed on components of the two energy absorbers, which were designed to limit average vertical accelerations to 25- to 40-g, to minimize peak crush loads, and to generate relatively long crush stroke values under dynamic loading conditions. Finite element models of the two energy absorbers utilized the Mat 58 model that had been verified through material characterization testing. Excellent predictions of the dynamic crushing response were obtained.
A FSI Enabled Practical Rotorcraft Flow Simulator for Morphing Blade Innovation
2015-05-08
morphing surface at different azimuthal angles . It can be found that the morphing surfaces do not deform at 0º and 22.5º, because the shock is...Apparently, due to the superposition of two speeds, the position and strength of shock change at different azimuthal angles . As shown in Figure 30, the...meters. The observer is stationary and the blade rotates periodically. This set up follows what would essentially be a wind tunnel set up. The blade
Keogh, Claire; Wallace, Emma; O’Brien, Kirsty K.; Galvin, Rose; Smith, Susan M.; Lewis, Cliona; Cummins, Anthony; Cousins, Grainne; Dimitrov, Borislav D.; Fahey, Tom
2014-01-01
PURPOSE We describe the methodology used to create a register of clinical prediction rules relevant to primary care. We also summarize the rules included in the register according to various characteristics. METHODS To identify relevant articles, we searched the MEDLINE database (PubMed) for the years 1980 to 2009 and supplemented the results with searches of secondary sources (books on clinical prediction rules) and personal resources (eg, experts in the field). The rules described in relevant articles were classified according to their clinical domain, the stage of development, and the clinical setting in which they were studied. RESULTS Our search identified clinical prediction rules reported between 1965 and 2009. The largest share of rules (37.2%) were retrieved from PubMed. The number of published rules increased substantially over the study decades. We included 745 articles in the register; many contained more than 1 clinical prediction rule study (eg, both a derivation study and a validation study), resulting in 989 individual studies. In all, 434 unique rules had gone through derivation; however, only 54.8% had been validated and merely 2.8% had undergone analysis of their impact on either the process or outcome of clinical care. The rules most commonly pertained to cardiovascular disease, respiratory, and musculoskeletal conditions. They had most often been studied in the primary care or emergency department settings. CONCLUSIONS Many clinical prediction rules have been derived, but only about half have been validated and few have been assessed for clinical impact. This lack of thorough evaluation for many rules makes it difficult to retrieve and identify those that are ready for use at the point of patient care. We plan to develop an international web-based register of clinical prediction rules and computer-based clinical decision support systems. PMID:25024245
Newton, Louise; Pront, Leeanne; Giles, Tracey M
2016-06-01
To examine the literature reporting the experiences and perceptions of registered nurses who supervise international nursing students in the clinical and classroom setting. Nursing education relies on clinical experts to supervise students during classroom and clinical education, and the quality of that supervision has a significant impact on student development and learning. Global migration and internationalisation of nursing education have led to increasing numbers of registered nurses supervising international nursing students. However, a paucity of relevant literature limits our understanding of these experiences. An integrative literature review. Comprehensive database searches of CINAHL, Informit, PubMed, Journals@Ovid, Findit@flinders and Medline were undertaken. Screening of 179 articles resulted in 10 included for review. Appraisal and analysis using Whittemore and Knafl's (Journal of Advanced Nursing, 52, 2005, 546) five stage integrative review recommendations was undertaken. This review highlighted some unique challenges for registered nurses supervising international nursing students. Identified issues were, a heightened sense of responsibility, additional pastoral care challenges, considerable time investments, communication challenges and cultural differences between teaching and learning styles. It is possible that these unique challenges could be minimised by implementing role preparation programmes specific to international nursing student supervision. Further research is needed to provide an in-depth exploration of current levels of preparation and support to make recommendations for future practice, education and policy development. An awareness of the specific cultural learning needs of international nursing students is an important first step to the provision of culturally competent supervision for this cohort of students. There is an urgent need for education and role preparation for all registered nurses supervising international nursing students, along with adequate recognition of the additional time required to effectively supervise these students. © 2016 John Wiley & Sons Ltd.
Mantwill, Sarah; Fiordelli, Maddalena; Ludolph, Ramona; Schulz, Peter J
2015-03-20
Diabetes education together with patient empowerment has shown to be key to effective self-management behavior. When delivered through information and communication technologies (ICT), this solution has shown to lead to better health outcomes. However, the potential of ICT and their integration into the healthcare environment have not yet been fully exploited. ICT should be in particular used to facilitate communication and information exchange between patient and healthcare providers. In addition, systems should include components facilitating behavior change using empowerment approaches such as goal-setting. Funded by the European Commission (FP7-ICT-2011-288209) a web/mobile based platform (EMPOWER) has been developed, which aims at supporting self-management activities of diabetes patients and their treating physicians in Germany and Turkey. The platform semantically integrates multiple information sources, such as electronic and personal health records (EHR/PHR). Patients can register patterns of daily living, record blood glucose levels, design disease management plans and set long- and short-term goals. The project actively involves the treating physician, who has the possibility to set recommendations for the patient and to monitor his/her progress on the platform. In the test-phase of EMPOWER, patients will be assigned to an intervention group and a control group. Data will be collected at baseline and three months after the intervention started. In addition, qualitative interviews will be conducted to collect extra information on usability and usefulness. Outcome measures include amongst others the Problem Areas in Diabetes questionnaire (PAID), the Summary of Diabetes Self-Care Activities and scales evaluating doctor-patient interaction. Physiological parameters, such as physical activity or blood glucose levels will be collected via the platform. Further, log files and number of logins will serve as independent variables. The interplay between multiple sources, including EHR, patients' own registered information and physicians' recommendations on one platform can have important practice implications. It might not only improve self-management activities in diabetes patients but it will also facilitate physician's work, and ultimately the physician patient relationship. The trial has been registered with Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS00007699 on January 30, 2015.
Nurses who work in rural and remote communities in Canada: a national survey.
MacLeod, Martha L P; Stewart, Norma J; Kulig, Judith C; Anguish, Penny; Andrews, Mary Ellen; Banner, Davina; Garraway, Leana; Hanlon, Neil; Karunanayake, Chandima; Kilpatrick, Kelley; Koren, Irene; Kosteniuk, Julie; Martin-Misener, Ruth; Mix, Nadine; Moffitt, Pertice; Olynick, Janna; Penz, Kelly; Sluggett, Larine; Van Pelt, Linda; Wilson, Erin; Zimmer, Lela
2017-05-23
In Canada, as in other parts of the world, there is geographic maldistribution of the nursing workforce, and insufficient attention is paid to the strengths and needs of those providing care in rural and remote settings. In order to inform workforce planning, a national study, Nursing Practice in Rural and Remote Canada II, was conducted with the rural and remote regulated nursing workforce (registered nurses, nurse practitioners, licensed or registered practical nurses, and registered psychiatric nurses) with the intent of informing policy and planning about improving nursing services and access to care. In this article, the study methods are described along with an examination of the characteristics of the rural and remote nursing workforce with a focus on important variations among nurse types and regions. A cross-sectional survey used a mailed questionnaire with persistent follow-up to achieve a stratified systematic sample of 3822 regulated nurses from all provinces and territories, living outside of the commuting zones of large urban centers and in the north of Canada. Rural workforce characteristics reported here suggest the persistence of key characteristics noted in a previous Canada-wide survey of rural registered nurses (2001-2002), namely the aging of the rural nursing workforce, the growth in baccalaureate education for registered nurses, and increasing casualization. Two thirds of the nurses grew up in a community of under 10 000 people. While nurses' levels of satisfaction with their nursing practice and community are generally high, significant variations were noted by nurse type. Nurses reported coming to rural communities to work for reasons of location, interest in the practice setting, and income, and staying for similar reasons. Important variations were noted by nurse type and region. The proportion of the rural nursing workforce in Canada is continuing to decline in relation to the proportion of the Canadian population in rural and remote settings. Survey results about the characteristics and practice of the various types of nurses can support workforce planning to improve nursing services and access to care.
Clinical assessment of the accuracy of blood glucose measurement devices.
Pfützner, Andreas; Mitri, Michael; Musholt, Petra B; Sachsenheimer, Daniela; Borchert, Marcus; Yap, Andrew; Forst, Thomas
2012-04-01
Blood glucose meters for patient self-measurement need to comply with the accuracy standards of the ISO 15197 guideline. We investigated the accuracy of the two new blood glucose meters BG*Star and iBG*Star (Sanofi-Aventis) in comparison to four other competitive devices (Accu-Chek Aviva, Roche Diagnostics; FreeStyle Freedom Lite, Abbott Medisense; Contour, Bayer; OneTouch Ultra 2, Lifescan) at different blood glucose ranges in a clinical setting with healthy subjects and patients with type 1 and type 2 diabetes. BGStar and iBGStar are employ dynamic electrochemistry, which is supposed to result in highly accurate results. The study was performed on 106 participants (53 female, 53 male, age (mean ± SD): 46 ± 16 years, type 1: 32 patients, type 2: 34 patients, and 40 healthy subjects). Two devices from each type and strips from two different production lots were used for glucose assessment (∼200 readings/meter). Spontaneous glucose assessments and glucose or insulin interventions under medical supervision were applied to perform measurements in the different glucose ranges in accordance with the ISO 15197 requirements. Sample values <50 mg/dL and >400 mg/dL were prepared by laboratory manipulations. The YSI glucose analyzer (glucose oxidase method) served as the standard reference method which may be considered to be a limitation in light of glucose hexokinase-based meters. For all devices, there was a very close correlation between the glucose results compared to the YSI reference method results. The correlation coefficients were r = 0.995 for BGStar and r = 0.992 for iBGStar (Aviva: 0.995, Freedom Lite: 0.990, Contour: 0.993, Ultra 2: 0.990). Error-grid analysis according to Parkes and Clarke revealed both 100% of the readings to be within the clinically acceptable areas (Clarke: A + B with BG*Star (100 + 0), Aviva (97 + 3), and Contour (97 + 3); and 99.5% with iBG*Star (97.5 + 2), Freedom Lite (98 + 1.5), and Ultra 2 (97.5 + 2)). This study demonstrated the very high accuracy of BG*Star, iBG*Star, and the competitive blood glucose meters in a clinical setting.
A new and inexpensive pyranometer for the visible spectral range.
Martínez, Miguel A; Andújar, José M; Enrique, Juan M
2009-01-01
This paper presents the design, construction and testing of a new photodiode-based pyranometer for the visible spectral range (approx. 400 to 750 nm), whose principal characteristics are: accuracy, ease of connection, immunity to noise, remote programming and operation, interior temperature regulation, cosine error minimisation and all this at a very low cost, tens of times lower than that of commercial thermopile-based devices. This new photodiode-based pyranometer overcomes traditional problems in this type of device and offers similar characteristics to those of thermopile-based pyranometers and, therefore, can be used in any installation where reliable measurement of solar irradiance is necessary, especially in those where cost is a deciding factor in the choice of a meter. This new pyranometer has been registered in the Spanish Patent and Trademark Office under the number P200703162.
A New and Inexpensive Pyranometer for the Visible Spectral Range
Martínez, Miguel A.; Andújar, José M.; Enrique, Juan M.
2009-01-01
This paper presents the design, construction and testing of a new photodiode-based pyranometer for the visible spectral range (approx. 400 to 750 nm), whose principal characteristics are: accuracy, ease of connection, immunity to noise, remote programming and operation, interior temperature regulation, cosine error minimisation and all this at a very low cost, tens of times lower than that of commercial thermopile-based devices. This new photodiode-based pyranometer overcomes traditional problems in this type of device and offers similar characteristics to those of thermopile-based pyranometers and, therefore, can be used in any installation where reliable measurement of solar irradiance is necessary, especially in those where cost is a deciding factor in the choice of a meter. This new pyranometer has been registered in the Spanish Patent and Trademark Office under the number P200703162. PMID:22408545
NASA Technical Reports Server (NTRS)
Salomonson, Vincent V.
2002-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) on the NASA Earth Observing System (EOS) Terra and Aqua missions has shown considerable capability for mapping snowcover. The typical approach that has used, along with other criteria, the Normalized Snow Difference Index (NDSI) that takes the difference between 500 meter observations at 1.64 micrometers (MODIS band 6) and 0.555 micrometers (MODIS band 4) over the sum of these observations to determine whether MODIS pixels are snowcovered or not in mapping the extent of snowcover. For many hydrological and climate studies using remote sensing of snowcover, it is desirable to assess if the MODIS snowcover observations could not be enhanced by providing the fraction of snowcover in each MODIS observation (pixel). Pursuant to this objective studies have been conducted to assess whether there is sufficient "signal%o in the NDSI parameter to provide useful estimates of fractional snowcover in each MODIS 500 meter pixel. To accomplish this objective high spatial resolution (30 meter) Landsat snowcover observations were used and co-registered with MODIS 500 meter pixels. The NDSI approach was used to assess whether a Landsat pixel was or was not snowcovered. Then the number of snowcovered Landsat pixels within a MODIS pixel was used to determine the fraction of snowcover within each MODIS pixel. The e results were then used to develop statistical relationships between the NDSI value for each 500 meter MODIS pixel and the fraction of snowcover in the MODIS pixel. Such studies were conducted for three widely different areas covered by Landsat scenes in Alaska, Russia, and the Quebec Province in Canada. The statistical relationships indicate that a 10 percent accuracy can be attained. The variability in the statistical relationship for the three areas was found to be remarkably similar (-0.02 for mean error and less than 0.01 for mean absolute error and standard deviation). Independent tests of the relationships were accomplished by taking the relationship of fractional snow-cover to NDSI from one area (e.g., Alaska) and testing it on the other two areas (e.g. Russia and Quebec). Again the results showed that fractional snow-cover can be estimated to 10 percent. The results have been shown to have advantages over other published fractional snowcover algorithms applied to MODIS data. Most recently the fractional snow-cover algorithm has been applied using 500-meter observations over the state of Colorado for a period spanning 25 days. The results exhibit good behavior in mapping the spatial and temporal variability in snowcover over that 25-day period. Overall these studies indicate that robust estimates of fractional snow-cover can be attained using the NDSI parameter over areas extending in size from watersheds relatively large compared to MODIS pixels to global land cover. Other refinements to this approach as well as different approaches are being examined for mapping fractional snow-cover using MODIS observations.
36 CFR 60.1 - Authorization and expansion of the National Register.
Code of Federal Regulations, 2010 CFR
2010-07-01
... districts, sites, buildings, structures, and objects significant in American history, architecture, archeology, engineering and culture. The regulations herein set forth the procedural requirements for listing...
"But my doctor recommended pot": medical marijuana and the patient-physician relationship.
Nussbaum, Abraham M; Boyer, Jonathan A; Kondrad, Elin C
2011-11-01
As the use of medical marijuana expands, it is important to consider its implications for the patient-physician relationship. In Colorado, a small cohort of physicians is recommending marijuana, with 15 physicians registering 49% of all medical marijuana patients and a single physician registering 10% of all patients. Together, they have registered more than 2% of the state to use medical marijuana in the last three years. We are concerned that this dramatic expansion is occurring in a setting rife with conflicts of interest despite insufficient scientific knowledge about marijuana. This system diminishes the patient-physician relationship to the recommendation of a single substance while unburdening physicians of their usual responsibilities to the welfare of their patients.
Deployable Emergency Shutoff Device Blocks High-Velocity Fluid Flows
NASA Technical Reports Server (NTRS)
Nabors, Sammy A.
2015-01-01
NASA's Marshall Space Flight Center has developed a device and method for blocking the flow of fluid from an open pipe. Motivated by the sea-bed oil-drilling catastrophe in the Gulf of Mexico in 2010, NASA innovators designed the device to plug, control, and meter the flow of gases and liquids. Anchored with friction fittings, spikes, or explosively activated fasteners, the device is well-suited for harsh environments and high fluid velocities and pressures. With the addition of instrumentation, it can also be used as a variable area flow metering valve that can be set based upon flow conditions. With robotic additions, this patent-pending innovation can be configured to crawl into a pipe then anchor and activate itself to block or control fluid flow.
A detailed gravimetric geoid of North America, Eurasia, and Australia
NASA Technical Reports Server (NTRS)
Vincent, S.; Strange, W. E.
1972-01-01
A detailed gravimetric geoid of North America, the North Atlantic, Eurasia, and Australia computed from a combination of satellite-derived and surface 1 x 1 gravity data, is presented. Using a consistent set of parameters, this geoid is referenced to an absolute datum. The precision of this detailed geoid is + or - 2 meters in the continents but may be in the range of 5 to 7 meters in those areas where data was sparse. Comparisons of the detailed gravimetric geoid with results of Rice for the United States, Bomford and Fischer in Eurasia, and Mather in Australia are presented. Comparisons are also presented with geoid heights from satellite solutions for geocentric station coordinates in North America, the Caribbean, Europe, and Australia.
Use of Visible Satellite Imagery to Determine Velocity in Tidal Rivers
NASA Astrophysics Data System (ADS)
Mied, R. P.; Donato, T. F.; Chen, W.
2006-05-01
In the open ocean and on the continental shelf, current velocities have traditionally been calculated remotely using the Maximum Correlation Coefficient (MCC) technique to track features between sequential sea surface temperature image scenes. These images are obtained from NOAA polar orbiters having an effective ground pixel size of 1.47 km. In contrast to this relatively large distance, spatial scales over which current velocities can vary in rivers and estuaries are hundreds of meters; associated temporal scales vary from tens of minutes to hours. Traditional in-situ measurements can be instructive in determining some aspects of the flow, but truly synoptic overviews are possible only with remote sensing, provided high-resolution imagery is available. With the advent of a constellation of moderate- to high-resolution imaging systems (e.g., Landsat, ASTER, SPOT, Quickbird, Ikonos, and Orbview-3) it is now available to extend current estimations to these areas. For instance, Landsat-7 and ASTER produce imagery with spatial resolutions on the order of 30 m or less and within 30 min of each other. This is sufficient to spatially resolve a wide variety of surface features, and to maintain feature integrity over time for tracking purposes. We apply this approach to a portion of the tidal Potomac River by using pairs of co-registered, sequential, multi-spectral Landsat-7 and ASTER images. The final data used in the analysis set contain three spectral bands (green, red, and near-infrared), and have a ground pixel spacing (GSD) of 30m. The time step between each Landsat-7 and ASTER pair is approximately 29 minutes. Two image sets are used in the present study, one occurring on 5 October 2001 and the other on 2 April 2003. We show current maps derived from both image pairs an discuss the results in the light of model and
NASA Astrophysics Data System (ADS)
Girod, L.; Nuth, C.; Schellenberger, T.
2014-12-01
The capability of structure from motion techniques to survey glaciers with a very high spatial and temporal resolution is a promising tool for better understanding the dynamic changes of glaciers. Modern software and computing power allow us to produce accurate data sets from low cost surveys, thus improving the observational capabilities on a wider range of glaciers and glacial processes. In particular, highly accurate glacier volume change monitoring and 3D movement computations will be possible Taking advantage of the helicopter flight needed to survey the ice stakes on Kronenbreen, NW Svalbard, we acquired high resolution photogrammetric data over the well-studied Midre Lovénbreen in September 2013. GoPro Hero 2 cameras were attached to the landing gear of the helicopter, acquiring two images per second. A C/A code based GPS was used for registering the stereoscopic model. Camera clock calibration is obtained through fitting together the shapes of the flight given by both the GPS logger and the relative orientation of the images. A DEM and an ortho-image are generated at 30cm resolution from 300 images collected. The comparison with a 2005 LiDAR DEM (5 meters resolution) shows an absolute error in the direct registration of about 6±3m in 3D which could be easily reduced to 1,5±1m by using fine point cloud alignment algorithms on stable ground. Due to the different nature of the acquisition method, it was not possible to use tie point based co-registration. A combination of the DEM and ortho-image is shown with the point cloud in figure below. A second photogrammetric data set will be acquired in September 2014 to survey the annual volume change and movement. These measurements will then be compared to the annual resolution glaciological stake mass balance and velocity measurements to assess the precision of the method to monitor at an annual resolution.
NASA Technical Reports Server (NTRS)
Robinson, John E.
2014-01-01
The Federal Aviation Administration's Next Generation Air Transportation System will combine advanced air traffic management technologies, performance-based procedures, and state-of-the-art avionics to maintain efficient operations throughout the entire arrival phase of flight. Flight deck Interval Management (FIM) operations are expected to use sophisticated airborne spacing capabilities to meet precise in-trail spacing from top-of-descent to touchdown. Recent human-in-the-loop simulations by the National Aeronautics and Space Administration have found that selection of the assigned spacing goal using the runway schedule can lead to premature interruptions of the FIM operation during periods of high traffic demand. This study compares three methods for calculating the assigned spacing goal for a FIM operation that is also subject to time-based metering constraints. The particular paradigms investigated include: one based upon the desired runway spacing interval, one based upon the desired meter fix spacing interval, and a composite method that combines both intervals. These three paradigms are evaluated for the primary arrival procedures to Phoenix Sky Harbor International Airport using the entire set of Rapid Update Cycle wind forecasts from 2011. For typical meter fix and runway spacing intervals, the runway- and meter fix-based paradigms exhibit moderate FIM interruption rates due to their inability to consider multiple metering constraints. The addition of larger separation buffers decreases the FIM interruption rate but also significantly reduces the achievable runway throughput. The composite paradigm causes no FIM interruptions, and maintains higher runway throughput more often than the other paradigms. A key implication of the results with respect to time-based metering is that FIM operations using a single assigned spacing goal will not allow reduction of the arrival schedule's excess spacing buffer. Alternative solutions for conducting the FIM operation in a manner more compatible with the arrival schedule are discussed in detail.
Design and Performance of a Wideband Radio Telescope
NASA Technical Reports Server (NTRS)
Weinreb, Sander; Imbriale, William A.; Jones, Glenn; Mani, Handi
2012-01-01
The Goldstone Apple Valley Radio Telescope (GAVRT) is an outreach project, a partnership involving NASA's Jet Propulsion Laboratory (JPL), the Lewis Center for Educational Research (LCER), and the Apple Valley Unified School District near the NASA Goldstone deep space communication complex. This educational program currently uses a 34-meter antenna, DSS12, at Goldstone for classroom radio astronomy observations via the Internet. The current program utilizes DSS12 in two narrow frequency bands around S-band (2.3 GHz) and X-band (8.45 GHz), and is used by a training program involving a large number of secondary school teachers and their classrooms. To expand the program, a joint JPL/LCER project was started in mid-2006 to retrofit an additional existing 34-meter beam-waveguide antenna, DSS28, with wideband feeds and receivers to cover the 0.5-to- 14-GHz frequency bands. The DSS28 antenna has a 34-meter diameter main reflector, a 2.54-meter subreflector, and a set of beam waveguide mirrors surrounded by a 2.43-meter tube. The antenna was designed for high power and a narrow frequency band around 7.2 GHz. The performance at the low end of the frequency band desired for the educational program would be extremely poor if the beam waveguide system was used as part of the feed system. Consequently, the 34-meter antenna was retrofitted with a tertiary offset mirror placed at the vertex of the main reflector. The tertiary mirror can be rotated to use two wideband feeds that cover the 0.5-to-14-GHz band. The earlier designs for both GAVRT and the DSN only used narrow band feeds and consequently, only covered a small part of the S- and X-band frequencies. By using both a wideband feed and wideband amplifiers, the entire band from 0.5 to 14 GHz is covered, expanding significantly the science activities that can be studied using this system.
Murray, David; Stankovic, Lina; Stankovic, Vladimir
2017-01-01
Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical load measurements dataset described in this paper includes whole house aggregate loads and nine individual appliance measurements at 8-second intervals per house, collected continuously over a period of two years from 20 houses. During monitoring, the occupants were conducting their usual routines. At the time of publishing, the dataset has the largest number of houses monitored in the United Kingdom at less than 1-minute intervals over a period greater than one year. The dataset comprises 1,194,958,790 readings, that represent over 250,000 monitored appliance uses. The data is accessible in an easy-to-use comma-separated format, is time-stamped and cleaned to remove invalid measurements, correctly label appliance data and fill in small gaps of missing data. PMID:28055033
Schibler, Andreas; Hammer, Jürg; Isler, Ruedi; Buess, Christian; Newth, Christopher J L
2004-01-01
Measurement of functional residual capacity (FRC) during mechanical ventilation is important to standardise respiratory system compliance and adjust the ventilator settings to optimise lung recruitment. In the present study we compared three methods to measure FRC. The bias flow nitrogen washout technique (FRC(N2MC)), the multiple breath nitrogen washout (FRC(MBNW)) and the multiple breath sulphur-hexafluoride washout using the molar mass signal of an ultrasonic flow meter (FRC(MBSF6)) were compared in six adult monkeys after endotracheal intubation and during spontaneous breathing and mechanical ventilation at three different positive end-expiratory pressure (PEEP) levels of 0, 5 and 10 cmH2O. Animal research laboratory. We found good agreement between all three methods and they all accurately measured changes in FRC when PEEP was increased. The coefficients of variance of the three measurement techniques were in the same range (1.3-9.2%). The measurement of the tracer gas concentration with the molar mass signal of the ultrasonic flow meter provides a good and simple alternative to respiratory mass spectrometer for FRC measurements in ventilated subjects.
NASA Astrophysics Data System (ADS)
Murray, David; Stankovic, Lina; Stankovic, Vladimir
2017-01-01
Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical load measurements dataset described in this paper includes whole house aggregate loads and nine individual appliance measurements at 8-second intervals per house, collected continuously over a period of two years from 20 houses. During monitoring, the occupants were conducting their usual routines. At the time of publishing, the dataset has the largest number of houses monitored in the United Kingdom at less than 1-minute intervals over a period greater than one year. The dataset comprises 1,194,958,790 readings, that represent over 250,000 monitored appliance uses. The data is accessible in an easy-to-use comma-separated format, is time-stamped and cleaned to remove invalid measurements, correctly label appliance data and fill in small gaps of missing data.
Murray, David; Stankovic, Lina; Stankovic, Vladimir
2017-01-05
Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical load measurements dataset described in this paper includes whole house aggregate loads and nine individual appliance measurements at 8-second intervals per house, collected continuously over a period of two years from 20 houses. During monitoring, the occupants were conducting their usual routines. At the time of publishing, the dataset has the largest number of houses monitored in the United Kingdom at less than 1-minute intervals over a period greater than one year. The dataset comprises 1,194,958,790 readings, that represent over 250,000 monitored appliance uses. The data is accessible in an easy-to-use comma-separated format, is time-stamped and cleaned to remove invalid measurements, correctly label appliance data and fill in small gaps of missing data.
Priority of road maintenance management based on halda reading range on NAASRA method
NASA Astrophysics Data System (ADS)
Surbakti, M.; Doan, A.
2018-02-01
The road pavement, constantly experiencing stress-strain due to traffic load through it, can cause damage to the pavement. Therefore, early detection and repair of the damage will be able to prevent more severe damage that can develop into pavement failure. A road condition survey is one of the earliest attempts to detect the initial damage of a pavement. In this case the driving comfort is the most important part for the driver in assessing road conditions that are affected by the level of road surface roughness. To determine the level of roughness of the road, one of the methods developed is the measurement using the NAASRA method. In this method the roughness of the road is an accumulation of the average unevenness of the road, with the general setting on halda of 100 m. However, with this 100-meter setting, in some places the final value of the roughness value is too large or too small so that it will result in the priority of the road maintenance. This is what underlies roughness research by comparing halda settings at 50 m and 200 m different from the general settings above.This study uses the International Roughness Index (IRI) method in determining the level of road stability concerning driving discomfort. IRI score obtained from direct survey in field by using Roughometer-NAASRA.The final result shows that there is a significant difference between the reading of halda which is set at 100 m reading with halda set with 50 and 200 meter readings. This may lead to differences in handling priorities, which may impact on the sustainability of road network maintenance management (Sustainaible Road Management)
Establishing and maintaining the National Vaccination Register in Finland.
Baum, Ulrike; Sundman, Jonas; Jääskeläinen, Susanna; Nohynek, Hanna; Puumalainen, Taneli; Jokinen, Jukka
2017-04-27
Computerised, population-based vaccination registers are valuable tools for assessing the vaccine uptake and impact in populations. However, reliable impact assessment is only possible if the data quality can be reviewed and monitored continuously. This report describes the establishment and maintenance of the National Vaccination Register (NVR) in Finland. Currently, the NVR covers nationwide records of vaccinations given within the frame of the National Vaccination Programme since 2009. All vaccinations registered in the NVR contain a record of the personal identity code, the administered vaccine, and the date of vaccination. The vaccine lot number is the key component for recording and identifying vaccinations, because of its broad availability across patient information systems and its importance in vaccine safety monitoring. Vaccination records are accumulated and updated daily into the NVR, and their completeness is monitored monthly to assess deficiencies in data entry and data collection. Additionally, an alert system reports unexpected changes in data accumulation prompting the validation of observed changes in vaccination coverage. The presented process documentation may serve as basis to improve the design and quality of other vaccination or healthcare registers and aims to inspire the set-up of vaccination registers in those countries which still do not have one. This article is copyright of The Authors, 2017.
Optimization Based Data Mining Approah for Forecasting Real-Time Energy Demand
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omitaomu, Olufemi A; Li, Xueping; Zhou, Shengchao
The worldwide concern over environmental degradation, increasing pressure on electric utility companies to meet peak energy demand, and the requirement to avoid purchasing power from the real-time energy market are motivating the utility companies to explore new approaches for forecasting energy demand. Until now, most approaches for forecasting energy demand rely on monthly electrical consumption data. The emergence of smart meters data is changing the data space for electric utility companies, and creating opportunities for utility companies to collect and analyze energy consumption data at a much finer temporal resolution of at least 15-minutes interval. While the data granularity providedmore » by smart meters is important, there are still other challenges in forecasting energy demand; these challenges include lack of information about appliances usage and occupants behavior. Consequently, in this paper, we develop an optimization based data mining approach for forecasting real-time energy demand using smart meters data. The objective of our approach is to develop a robust estimation of energy demand without access to these other building and behavior data. Specifically, the forecasting problem is formulated as a quadratic programming problem and solved using the so-called support vector machine (SVM) technique in an online setting. The parameters of the SVM technique are optimized using simulated annealing approach. The proposed approach is applied to hourly smart meters data for several residential customers over several days.« less
Aswan High Dam in 6-meter Resolution from the International Space Station
NASA Technical Reports Server (NTRS)
2002-01-01
Astronaut photography of the Earth from the International Space Station has achieved resolutions close to those available from commercial remote sensing satellites-with many photographs having spatial resolutions of less than six meters. Astronauts take the photographs by hand and physically compensate for the motion of the spacecraft relative to the Earth while the images are being acquired. The achievement was highlighted in an article entitled 'Space Station Allows Remote Sensing of Earth to within Six Meters' published in this week's edition of Eos, Transactions of the American Geophysical Union. Lines painted on airport runways at the Aswan Airport served to independently validate the spatial resolution of the camera sensor. For press information, read: International Space Station Astronauts Set New Standard for Earth Photography For details, see Robinson, J. A. and Evans, C. A. 2002. Space Station Allows Remote Sensing of Earth to within Six Meters. Eos, Transactions, American Geophysical Union 83(17):185, 188. See some of the other detailed photographs posted to Earth Observatory: Pyramids at Giza Bermuda Downtown Houston The image above represents a detailed portion of a digitized NASA photograph STS102-303-17, and was provided by the Earth Sciences and Image Analysis Laboratory at Johnson Space Center. Additional images taken by astronauts and cosmonauts can be viewed at the NASA-JSC Gateway to Astronaut Photography of Earth.
2.1 meter (82 inch) Slip Ring By-Pass Project
NASA Astrophysics Data System (ADS)
Bryan, Corby B.
2006-12-01
2.1 meter (82 inch) Slip Ring By-Pass Project I will describe a project to bypass the old method of getting control communications above the rotation point of the McDonald Observatory 2.1 meter dome. The old method used slip rings that were implemented in the late 1930s. The new system uses wireless serial commands which allow the control lines to be taken off the slip rings, leaving only power and ground. I will describe how the concept was devised so the slip rings could be by-passed, what micro-controller system that was decided on and used, how the wireless units were set up and finally how the system was tested and put in place with only limited tasks to control. (I.E. the opening and closing of the shutters) We describe the advantages to making this upgrade and how it could benefit any telescope interested in upgrading its communication systems. This project was designed and tested in ten weeks during the McDonald Observatory REU and was supported under NSF AST-0243745. The system was designed so that it could be installed while running side by side with the current method of getting control to the above rotation point. The method is still in place being tested on the 2.1 meter telescope and will soon be fully implemented by the University of Texas McDonald Observatory OS staff.
A seepage meter designed for use in flowing water
Rosenberry, D.O.
2008-01-01
Seepage meters provide one of the most direct means to measure exchange of water across the sediment-water interface, but they generally have been unsuitable for use in fluvial settings. Although the seepage bag can be placed inside a rigid container to minimize velocity head concerns, the seepage cylinder installed in the sediment bed projects into and disrupts the flow field, altering both the local-scale fluid exchange as well as measurement of that exchange. A low-profile seepage meter designed for use in moving water was tested in a seepage meter flux tank where both current velocity and seepage velocity could be controlled. The conical seepage cylinder protrudes only slightly above the sediment bed and is connected via tubing to a seepage bag or flowmeter positioned inside a rigid shelter that is located nearby where current velocity is much slower. Laboratory and field tests indicate that the net effect of the small protrusion of the seepage cylinder into the surface water flow field is inconsequentially small for surface water currents up to 65 cm s-1. Current velocity affects the variability of seepage measurements; seepage standard deviation increased from ???2 to ???6 cm d-1 as current velocity increased from 9 to 65 cm s-1. Substantial bias can result if the shelter is not placed to minimize hydraulic gradient between the bag and the seepage cylinder.
NASA Astrophysics Data System (ADS)
Boyarnikov, A. V.; Boyarnikova, L. V.; Kozhushko, A. A.; Sekachev, A. F.
2017-08-01
In the article the process of verification (calibration) of oil metering units secondary equipment is considered. The purpose of the work is to increase the reliability and reduce the complexity of this process by developing a software and hardware system that provides automated verification and calibration. The hardware part of this complex carries out the commutation of the measuring channels of the verified controller and the reference channels of the calibrator in accordance with the introduced algorithm. The developed software allows controlling the commutation of channels, setting values on the calibrator, reading the measured data from the controller, calculating errors and compiling protocols. This system can be used for checking the controllers of the secondary equipment of the oil metering units in the automatic verification mode (with the open communication protocol) or in the semi-automatic verification mode (without it). The peculiar feature of the approach used is the development of a universal signal switch operating under software control, which can be configured for various verification methods (calibration), which allows to cover the entire range of controllers of metering units secondary equipment. The use of automatic verification with the help of a hardware and software system allows to shorten the verification time by 5-10 times and to increase the reliability of measurements, excluding the influence of the human factor.
Full-custom design of split-set data weighted averaging with output register for jitter suppression
NASA Astrophysics Data System (ADS)
Jubay, M. C.; Gerasta, O. J.
2015-06-01
A full-custom design of an element selection algorithm, named as Split-set Data Weighted Averaging (SDWA) is implemented in 90nm CMOS Technology Synopsys Library. SDWA is applied in seven unit elements (3-bit) using a thermometer-coded input. Split-set DWA is an improved DWA algorithm which caters the requirement for randomization along with long-term equal element usage. Randomization and equal element-usage improve the spectral response of the unit elements due to higher Spurious-free dynamic range (SFDR) and without significantly degrading signal-to-noise ratio (SNR). Since a full-custom, the design is brought to transistor-level and the chip custom layout is also provided, having a total area of 0.3mm2, a power consumption of 0.566 mW, and simulated at 50MHz clock frequency. On this implementation, SDWA is successfully derived and improved by introducing a register at the output that suppresses the jitter introduced at the final stage due to switching loops and successive delays.
78 FR 66666 - Airworthiness Directives; Diamond Aircraft Industries GmbH Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-06
... available in the AD docket shortly after receipt. FOR FURTHER INFORMATION CONTACT: Mike Kiesov, Aerospace... Invited We invite you to send any written relevant data, views, or arguments about this proposed AD. Send... trigger by using the G1000 ampere-meter signals. The trigger is set once an alternator provides less than...
ERIC Educational Resources Information Center
Crawford, Christina; Beason-Abmayr, Beth; Eich, Elizabeth; Scott, Jamie; Nichol, Carolyn
2015-01-01
Viruses are all around--and within. They replicate inside the cells of living organisms. An estimated 1.6 million to 40 million of them occupy each cubic meter of the air people breathe. The activity described in this article helps students understand how the structure of a virus allows it to infect a specific set of organisms and cell types.…
van Dam, Joris; Tadmor, Brigitta; Spector, Jonathan; Musuku, John; Zühlke, Liesl J; Zühlke, Liesl J; Engel, Mark E; Mayosi, Bongani M; Nestle, Nick
2015-01-01
Summary Background Rheumatic heart disease (RHD) remains a major disease burden in low-resource settings globally. Patient registers have long been recognised to be an essential instrument in RHD control and elimination programmes, yet to date rely heavily on paper-based data collection and non-networked data-management systems, which limit their functionality. Objectives To assess the feasibility and potential benefits of producing an electronic RHD patient register. Methods We developed an eRegister based on the World Heart Federation’s framework for RHD patient registers using CommCare, an open-source, cloud-based software for health programmes that supports the development of customised data capture using mobile devices. Results The resulting eRegistry application allows for simultaneous data collection and entry by field workers using mobile devices, and by providers using computer terminals in clinics and hospitals. Data are extracted from CommCare and are securely uploaded into a cloud-based database that matches the criteria established by the WHF framework. The application can easily be tailored to local needs by modifying existing variables or adding new ones. Compared with traditional paper-based data-collection systems, the eRegister reduces the risk of data error, synchronises in real-time, improves clinical operations and supports management of field team operations. Conclusions The user-friendly eRegister is a low-cost, mobile, compatible platform for RHD treatment and prevention programmes based on materials sanctioned by the World Heart Federation. Readily adaptable to local needs, this paperless RHD patient register program presents many practical benefits. PMID:26444995
Registered nurses' attention to and perceptions of pressure ulcer prevention in hospital settings.
Sving, Eva; Gunningberg, Lena; Högman, Marieann; Mamhidir, Anna-Greta
2012-05-01
To describe how registered nurses perform, document and reflect on pressure ulcer prevention in a specific nurse-patient care situation, as well as generally, on hospital wards. Registered nurses should provide safe and qualified pressure ulcer prevention, but pressure ulcers remain a problem. Compliance with evidence-based guidelines impedes pressure ulcer formation. A descriptive design with a multimethods approach. Nine registered nurses at three wards and hospitals participated. The registered nurses were observed in a specific nurse-patient care situation with patients at risk for pressure ulcers. Interviews followed and patients' records were reviewed. Quantitative and qualitative data analysis methods were used. Pressure ulcer prevention performed by the registered nurses was dependent on the cultural care, which ranged from planned to unplanned prevention. Diversity was found in compliance with evidence-based guidelines across the wards. Although all patients involved were at risk and the nurses described pressure ulcer prevention as basic care, the nurses' attention to prevention was lacking. Few prevention activities and no structured risk assessments using risk assessment tools were observed, and few care plans were identified. The lack of attention was explained by registered nurses' trust in assistant nurses' knowledge, and prevention was seen as an assistant nurse task. Registered nurses paid little attention to pressure ulcer prevention among patients at risk. The planned and unplanned care structures affected the prevention. The nurses trusted and largely delegated their responsibility to the assistant nurses. Evidence-based pressure ulcer prevention is fundamental to patient safety. Care quality is created in situations where patients and care providers meet. How registered nurses work with pressure ulcer prevention, their role and communication, particularly with assistant nurses, should be of major concern to them as well as to healthcare managers. © 2012 Blackwell Publishing Ltd.
29 CFR 30.1 - Scope and purpose.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... This part sets forth policies and procedures to promote equality of opportunity in apprenticeship... registering of apprenticeship programs for Federal purposes. The purpose of this part is to promote equality...
Code of Federal Regulations, 2011 CFR
2011-10-01
... officer shall perform market research and document why a small business set-aside is inappropriate when an... market price. [48 FR 42240, Sept. 19, 1983] Editorial Note: For Federal Register citations affecting...
World Globes, Shaded Relief and Colored Height
2003-08-21
These images of the world were generated with data from the Shuttle Radar Topography Mission (SRTM). The SRTM Project has recently released a new global data set called SRTM30, where the original one arcsecond of latitude and longitude resolution (about 30 meters, or 98 feet, at the equator) was reduced to 30 arcseconds (about 928 meters, or 1496 feet.) These images were created from that data set and show the Earth as it would be viewed from a point in space centered over the Americas, Africa and the western Pacific. Two visualization methods were combined to produce the image: shading and color coding of topographic height. The shade image was derived by computing topographic slope in the northwest-southeast direction, so that northwest slopes appear bright and southeast slopes appear dark. Color coding is directly related to topographic height, with green at the lower elevations, rising through yellow and tan, to white at the highest elevations. Elevation data used in this image were acquired by the Shuttle Radar Topography Mission aboard the Space Shuttle Endeavour, launched on Feb. 11, 2000. http://photojournal.jpl.nasa.gov/catalog/PIA03394
Modeling tidal hydrodynamics of San Diego Bay, California
Wang, P.-F.; Cheng, R.T.; Richter, K.; Gross, E.S.; Sutton, D.; Gartner, J.W.
1998-01-01
In 1983, current data were collected by the National Oceanic and Atmospheric Administration using mechanical current meters. During 1992 through 1996, acoustic Doppler current profilers as well as mechanical current meters and tide gauges were used. These measurements not only document tides and tidal currents in San Diego Bay, but also provide independent data sets for model calibration and verification. A high resolution (100-m grid), depth-averaged, numerical hydrodynamic model has been implemented for San Diego Bay to describe essential tidal hydrodynamic processes in the bay. The model is calibrated using the 1983 data set and verified using the more recent 1992-1996 data. Discrepancies between model predictions and field data in beth model calibration and verification are on the order of the magnitude of uncertainties in the field data. The calibrated and verified numerical model has been used to quantify residence time and dilution and flushing of contaminant effluent into San Diego Bay. Furthermore, the numerical model has become an important research tool in ongoing hydrodynamic and water quality studies and in guiding future field data collection programs.
Moving on? Predictors of Intent to Leave among Rural and Remote RNs in Canada
ERIC Educational Resources Information Center
Stewart, Norma J.; D'Arcy, Carl; Kosteniuk, Julie; Andrews, Mary Ellen; Morgan, Debra; Forbes, Dorothy; MacLeod, Martha L. P.; Kulig, Judith C.; Pitblado, J. Roger
2011-01-01
Context: Examination of factors related to the retention or voluntary turnover of Registered Nurses (RNs) has mainly focused on urban, acute care settings. Purpose: This paper explored predictors of intent to leave (ITL) a nursing position in all rural and remote practice settings in Canada. Based on the conceptual framework developed for this…
ERIC Educational Resources Information Center
Cagginello, Joan; Blackborow, Mary; Porter, Jessica; Disney, Jody; Andresen, Kathleen; Tuck, Christine
2014-01-01
It is the position of the National Association of School Nurses (NASN) that the delegation of nursing tasks in the school setting can be a valuable tool for the registered professional school nurse (hereinafter referred to as school nurse), when based on the nursing definition of delegation (American Nurses Association [ANA], 2012) and in…
Wallert, John; Tomasoni, Mattia; Madison, Guy; Held, Claes
2017-07-05
Machine learning algorithms hold potential for improved prediction of all-cause mortality in cardiovascular patients, yet have not previously been developed with high-quality population data. This study compared four popular machine learning algorithms trained on unselected, nation-wide population data from Sweden to solve the binary classification problem of predicting survival versus non-survival 2 years after first myocardial infarction (MI). This prospective national registry study for prognostic accuracy validation of predictive models used data from 51,943 complete first MI cases as registered during 6 years (2006-2011) in the national quality register SWEDEHEART/RIKS-HIA (90% coverage of all MIs in Sweden) with follow-up in the Cause of Death register (> 99% coverage). Primary outcome was AUROC (C-statistic) performance of each model on the untouched test set (40% of cases) after model development on the training set (60% of cases) with the full (39) predictor set. Model AUROCs were bootstrapped and compared, correcting the P-values for multiple comparisons with the Bonferroni method. Secondary outcomes were derived when varying sample size (1-100% of total) and predictor sets (39, 10, and 5) for each model. Analyses were repeated on 79,869 completed cases after multivariable imputation of predictors. A Support Vector Machine with a radial basis kernel developed on 39 predictors had the highest complete cases performance on the test set (AUROC = 0.845, PPV = 0.280, NPV = 0.966) outperforming Boosted C5.0 (0.845 vs. 0.841, P = 0.028) but not significantly higher than Logistic Regression or Random Forest. Models converged to the point of algorithm indifference with increased sample size and predictors. Using the top five predictors also produced good classifiers. Imputed analyses had slightly higher performance. Improved mortality prediction at hospital discharge after first MI is important for identifying high-risk individuals eligible for intensified treatment and care. All models performed accurately and similarly and because of the superior national coverage, the best model can potentially be used to better differentiate new patients, allowing for improved targeting of limited resources. Future research should focus on further model development and investigate possibilities for implementation.
Automated protocols for spaceborne sub-meter resolution "Big Data" products for Earth Science
NASA Astrophysics Data System (ADS)
Neigh, C. S. R.; Carroll, M.; Montesano, P.; Slayback, D. A.; Wooten, M.; Lyapustin, A.; Shean, D. E.; Alexandrov, O.; Macander, M. J.; Tucker, C. J.
2017-12-01
The volume of available remotely sensed data has grown exceeding Petabytes per year and the cost for data, storage systems and compute power have both dropped exponentially. This has opened the door for "Big Data" processing systems with high-end computing (HEC) such as the Google Earth Engine, NASA Earth Exchange (NEX), and NASA Center for Climate Simulation (NCCS). At the same time, commercial very high-resolution (VHR) satellites have grown into a constellation with global repeat coverage that can support existing NASA Earth observing missions with stereo and super-spectral capabilities. Through agreements with the National Geospatial-Intelligence Agency NASA-Goddard Space Flight Center is acquiring Petabytes of global sub-meter to 4 meter resolution imagery from WorldView-1,2,3 Quickbird-2, GeoEye-1 and IKONOS-2 satellites. These data are a valuable no-direct cost for the enhancement of Earth observation research that supports US government interests. We are currently developing automated protocols for generating VHR products to support NASA's Earth observing missions. These include two primary foci: 1) on demand VHR 1/2° ortho mosaics - process VHR to surface reflectance, orthorectify and co-register multi-temporal 2 m multispectral imagery compiled as user defined regional mosaics. This will provide an easy access dataset to investigate biodiversity, tree canopy closure, surface water fraction, and cropped area for smallholder agriculture; and 2) on demand VHR digital elevation models (DEMs) - process stereo VHR to extract VHR DEMs with the NASA Ames stereo pipeline. This will benefit Earth surface studies on the cryosphere (glacier mass balance, flow rates and snow depth), hydrology (lake/water body levels, landslides, subsidence) and biosphere (forest structure, canopy height/cover) among others. Recent examples of products used in NASA Earth Science projects will be provided. This HEC API could foster surmounting prior spatial-temporal limitations while providing broad benefits to Earth Science.
Earth Observations taken by the Expedition 10 crew
2005-04-02
ISS010-E-22495 (2 April 2005) --- Numerous recognizable features appear in this detailed view of London, United Kingdom, photographed by an Expedition 10 crewmember on the International Space Station (ISS). The photographer had to look back along track for the shot, from a position over northern Germany. The most striking visual features are green open spaces such as Regents Park, Hyde Park and St. Jamess Park east of Buckingham Palace. Many smaller parks indicate why Londoners are proud of being able to walk miles through the city mainly on grass. The River Thameswith its bridges and barges (some of the more than 14,000 craft registered to sail the Thames)is the axis upon which the city was founded in Roman times. The relatively small area known as the City of London coincides with the ancient walled Roman city of Londinium on the north bank of the river (the line of the wall is marked closely for almost its entire length by modern streets), and includes St. Pauls Cathedral near where the Roman temple stood. For scale, the river is 265 meters wide near St. Pauls. The City is the financial center while Westminster is the center of government, including the Houses of Parliament and Downing Street, where the British Prime Minister lives. Several large structures visible in this image are railroad stations; three serving areas north of London (Euston, St. Pancras and Kings Cross), and Waterloo Station serving southern Britain. The London Eye, a famous Ferris wheel 140 meters high, is situated on an oval island in the River Thames, visible just west of Waterloo Station. Many larger buildings can also be identified, partly because they cast shadowsBuckingham Palace, St Pauls Cathedral, and the Tate Modern art museum (a converted power station, the 99-meter chimney was designed to fall just short of the crest of St Pauls dome).
A Fault-tolerant RISC Microprocessor for Spacecraft Applications
NASA Technical Reports Server (NTRS)
Timoc, Constantin; Benz, Harry
1990-01-01
Viewgraphs on a fault-tolerant RISC microprocessor for spacecraft applications are presented. Topics covered include: reduced instruction set computer; fault tolerant registers; fault tolerant ALU; and double rail CMOS logic.
Anesetti-Rothermel, Andrew; Pearson, Jennifer L.; Xiao, Haijun; Vallone, Donna; Kirchner, Thomas R.
2014-01-01
Aims This study examined the impact of tobacco retail outlets on cessation outcomes over time among non-treatment-seeking smokers and assessed differences by neighborhood poverty and individual factors. Design Observational longitudinal cohort study using geospatial data. We used generalized estimating equations to examine cessation outcomes in relation to the proximity and density of tobacco retail outlets near the home. Setting Eight large Designated Media Areas across the U.S. Participants A total of 2,377 baseline smokers followed over 3 waves from 2008 to 2010. Measurements Outlet addresses were identified through North American Industry Classification System codes and proximity and density measures were constructed for each participant at each wave. Outcomes included past 30-day abstinence and pro-cessation attitudes. Findings Smokers in high poverty census tracts living between 500 meters and 1.9 kilometers from an outlet were over 2 times more likely to be abstinent than those living fewer than 500 meters from an outlet (p<.05). Density within 500 meters of home was associated with reduced abstinence (OR: 0.94; CI: 0.90, 0.98) and lower pro-cessation attitudes (Coef: −0.07, CI: −0.10, −0.03) only in high poverty areas. In low poverty areas, density within 500 meters was associated with greater pro-cessation attitudes (OR: 0.06; CI: 0.01, 0.12). Gender, education and heaviness of smoking did not moderate the impact of outlet proximity and density on cessation outcomes. Conclusions In the US, density of tobacco outlets within 500 meters of the home residence appears to be negatively associated with smoking abstinence and pro-cessation attitudes only in poor areas. PMID:25171184
Using aerial infrared thermography to detect utility theft of service
NASA Astrophysics Data System (ADS)
Stockton, Gregory R.; Lucas, R. Gillem
2012-06-01
Natural gas and electric utility companies, public utility commissions, consumer advocacy groups, city governments, state governments and the federal government United States continue to turn a blind eye towards utility energy theft of service which we conservatively estimate is in excess of 10 billion a year. Why? Many in the United States have exhausted their unemployment benefits. The amounts for federal funding for low income heating assistance programs (LIHEAP) funds were cut by nearly 40% for 2012 to 3.02 billion. "At peak funding ($5.1 billion in 2009), the program was national in scale but still only had enough resources to support roughly 1/4 of the eligible households.i" Contributions to charities are down and the number of families below the poverty line who are unable to pay to heat their houses continues to rise. Many of the less fortunate in our society now consider theft and fraud to be an attractive option for their supply of natural gas and/or electricity. A record high mild winter in 2011-2012 coupled with 10-year low natural gas prices temporarily obscured the need for low income heating assistance programs (LIHEAPs) from the news and federal budgets, but cold winters will return. The proliferation of smart meters and automated meter infrastructures across our nation can do little to detect energy theft because the thieves can simply by-pass the meters, jumper around the meters and/or steal meters from abandoned houses and use them. Many utility systems were never set-up to stop these types of theft. Even with low-cost per identified thief method using aerial infrared thermography, utilities continue to ignore theft detection.
NASA Astrophysics Data System (ADS)
Bochenska, T.; Limisiewicz, P.; Loprawski, L.
1995-03-01
In regions of intense mining, shortages of water are common. Increased water demand is normally associated with industry in mining areas, and mine unwatering has negative effects on the natural groundwater balance. The study area occupies 3,300 square kilometers within the copper mining region of Lubin-Glogow, southwestern Poland. Pumping of groundwater to drain mines has created a cone of depression that underlies 2,500 square kilometers. The lowering of potentiometric surfaces has occurred in deep aquifers, which are isolated from the surface by thick confining units (loams and clays). Changes of hydraulic head in the shallow aquifer have not previously been observed. In this study, the authors analyzed the water-table changes in the shallow aquifer. The statistical analysis of the water table was based on two sets of water-level measurements in about 1,200 farm wells during dry seasons. The first set was done in the fall of 1986, the second in the fall of 1991. In addition to these measurements, multi-seasonal observations were made by the mining survey in several tens of wells. During five years, the head declined an average of 0.4 meter. Locally, the lowering was as great as five meters. The regional decline of head resulted in a loss of water resources about 2×108 cubic meters. Regionally, this loss is not directly related to the dewatering of copper mines. Locally, however, mining activity strongly influences the water table. The general trend of the decline is probably an effect of decreasing precipitation.
Diving at altitude: from definition to practice.
Egi, S Murat; Pieri, Massimo; Marroni, Alessandro
2014-01-01
Diving above sea level has different motivations for recreational, military, commercial and scientific activities. Despite the apparently wide practice of inland diving, there are three major discrepancies about diving at altitude: threshold elevation that requires changes in sea level procedures; upper altitude limit of the applicability of these modifications; and independent validation of altitude adaptation methods of decompression algorithms. The first problem is solved by converting the normal fluctuation in barometric pressure to an altitude equivalent. Based on the barometric variations recorded from a meteorological center, it is possible to suggest 600 meters as a threshold for classifying a dive as an "altitude" dive. The second problem is solved by proposing the threshold altitude of aviation (2,400 meters) to classify "high" altitude dives. The DAN (Divers Alert Network) Europe diving database (DB) is analyzed to solve the third problem. The database consists of 65,050 dives collected from different dive computers. A total of 1,467 dives were found to be classified as altitude dives. However, by checking the elevation according to the logged geographical coordinates, 1,284 dives were disqualified because the altitude setting had been used as a conservative setting by the dive computer despite the fact that the dive was made at sea level. Furthermore, according to the description put forward in this manuscript, 72 dives were disqualified because the surface level elevation is lower than 600 meters. The number of field data (111 dives) is still very low to use for the validation of any particular method of altitude adaptation concerning decompression algorithms.
Lynch, B A; Jones, A; Biggs, B K; Kaufman, T; Cristiani, V; Kumar, S; Quigg, S; Maxson, J; Swenson, L; Jacobson, N
2015-12-01
The prevalence of pediatric obesity has increased over the past 3 decades and is a pressing public health program. New technology advancements that can encourage more physical in children are needed. The Zamzee program is an activity meter linked to a motivational website designed for children 8-14 years of age. The objective of the study was to use a collaborative approach between a medical center, the private sector and local school staff to assess the feasibility of using the Zamzee Program in the school-based setting to improve physical activity levels in children. This was a pilot 8-week observational study offered to all children in one fifth grade classroom. Body mass index (BMI), the amount of physical activity by 3-day recall survey, and satisfaction with usability of the Zamzee Program were measured pre- and post-study. Out of 11 children who enrolled in the study, 7 completed all study activities. In those who completed the study, the median (interquartile range) total activity time by survey increased by 17 (1042) minutes and the BMI percentile change was 0 (8). Both children and their caregivers found the Zamzee Activity Meter (6/7) and website (6/7) "very easy" or "easy" to use. The Zamzee Program was found to be usable but did not significantly improve physical activity levels or BMI. Collaborative obesity intervention projects involving medical centers, the private sector and local schools are feasible but the effectiveness needs to be evaluated in larger-scale studies.
Geophysical observations at cavity collapse
NASA Astrophysics Data System (ADS)
Jousset, Philippe; Bazargan-Sabet, Behrooz; Lebert, François; Bernardie, Séverine; Gourry, Jean-Christophe
2010-05-01
In Lorraine region (France) salt layers at about 200 meters depth are exploited by Solvay using solution mining methodology which consists in extracting the salt by dissolution, collapsing the cavern overburden during the exploitation phase and finally reclaiming the landscape by creating a water area. In this process, one of the main challenges for the exploiting company is to control the initial 120-m diameter collapse so as to minimize possible damages. In order to detect potential precursors and understand processes associated with such collapses, a wide series of monitoring techniques including micro seismics, broad-band seismology, hydro-acoustic, electromagnetism, gas probing, automatic leveling, continuous GPS, continuous gravity and borehole extensometry was set-up in the frame of an in-situ study carried out by the "Research Group for the Impact and Safety of Underground Works" (GISOS, France). Equipments were set-up well before the final collapse, giving a unique opportunity to analyze a great deal of information prior to and during the collapse process which has been successfully achieved on February the 13th, 2009 by controlling the cavity internal pressure. In this work, we present the results of data recorded by a network of 3 broadband seismometers, 2 accelerometers, 2 tilt-meters and a continuously gravity meter. We relate the variations of the brine pumping rate with the evolutions of the induced geophysical signals and finally we propose a first mechanical model for describing the controlled collapse. Beyond the studied case, extrapolation of the results obtained might contribute to the understanding of uncontrolled cavity collapses, such as pit-craters or calderas at volcanoes.
Park, Hyun-Seok
2012-12-01
Whereas a vast amount of new information on bioinformatics is made available to the public through patents, only a small set of patents are cited in academic papers. A detailed analysis of registered bioinformatics patents, using the existing patent search system, can provide valuable information links between science and technology. However, it is extremely difficult to select keywords to capture bioinformatics patents, reflecting the convergence of several underlying technologies. No single word or even several words are sufficient to identify such patents. The analysis of patent subclasses can provide valuable information. In this paper, I did a preliminary study of the current status of bioinformatics patents and their International Patent Classification (IPC) groups registered in the Korea Intellectual Property Rights Information Service (KIPRIS) database.
36 CFR 67.5 - Standards for evaluating significance within registered historic districts.
Code of Federal Regulations, 2014 CFR
2014-07-01
... a district is one which by location, design, setting, materials, workmanship, feeling and..., workmanship, feeling and association have been so altered or have so deteriorated that the overall integrity...
36 CFR 67.5 - Standards for evaluating significance within registered historic districts.
Code of Federal Regulations, 2012 CFR
2012-07-01
... a district is one which by location, design, setting, materials, workmanship, feeling and..., workmanship, feeling and association have been so altered or have so deteriorated that the overall integrity...
36 CFR 67.5 - Standards for evaluating significance within registered historic districts.
Code of Federal Regulations, 2011 CFR
2011-07-01
... a district is one which by location, design, setting, materials, workmanship, feeling and..., workmanship, feeling and association have been so altered or have so deteriorated that the overall integrity...
36 CFR 67.5 - Standards for evaluating significance within registered historic districts.
Code of Federal Regulations, 2013 CFR
2013-07-01
... a district is one which by location, design, setting, materials, workmanship, feeling and..., workmanship, feeling and association have been so altered or have so deteriorated that the overall integrity...
Characteristics of Pesticide Poisoning in Rural and Urban Settings in Uganda.
Pedersen, Bastian; Ssemugabo, Charles; Nabankema, Victoria; Jørs, Erik
2017-01-01
Pesticide poisoning is a significant burden on health care systems in many low-income countries. This study evaluates cases of registered pesticide poisonings treated in selected rural (N = 101) and urban (N = 212) health facilities in Uganda from January 2010 to August 2016. In the urban setting, pesticides were the most prevalent single poison responsible for intoxications (N = 212 [28.8%]). Self-harm constituted a significantly higher proportion of the total number of poisonings in urban (63.3%) compared with rural areas (25.6%) where unintentional poisonings prevailed. Men were older than women and represented a majority of around 60% of the cases in both the urban and rural settings. Unintentional cases were almost the only ones seen below the age of 10, whereas self-harm dominated among adolescents and young persons from 10 to 29 years of age. Organophosphorus insecticides accounted for 73.0% of the poisonings. Urban hospitals provided a more intensive treatment and had registered fever complications than rural health care settings. To minimize self-harm with pesticides, a restriction of pesticide availability as shown to be effective in other low-income countries is recommended. Training of health care workers in proper diagnosis and treatment of poisonings and improved equipment in the health care settings should be strengthened.
Characteristics of Pesticide Poisoning in Rural and Urban Settings in Uganda
Pedersen, Bastian; Ssemugabo, Charles; Nabankema, Victoria; Jørs, Erik
2017-01-01
Pesticide poisoning is a significant burden on health care systems in many low-income countries. This study evaluates cases of registered pesticide poisonings treated in selected rural (N = 101) and urban (N = 212) health facilities in Uganda from January 2010 to August 2016. In the urban setting, pesticides were the most prevalent single poison responsible for intoxications (N = 212 [28.8%]). Self-harm constituted a significantly higher proportion of the total number of poisonings in urban (63.3%) compared with rural areas (25.6%) where unintentional poisonings prevailed. Men were older than women and represented a majority of around 60% of the cases in both the urban and rural settings. Unintentional cases were almost the only ones seen below the age of 10, whereas self-harm dominated among adolescents and young persons from 10 to 29 years of age. Organophosphorus insecticides accounted for 73.0% of the poisonings. Urban hospitals provided a more intensive treatment and had registered fever complications than rural health care settings. To minimize self-harm with pesticides, a restriction of pesticide availability as shown to be effective in other low-income countries is recommended. Training of health care workers in proper diagnosis and treatment of poisonings and improved equipment in the health care settings should be strengthened. PMID:28615953
First Dutch Consensus of Pain Quality Indicators for Pain Treatment Facilities.
de Meij, Nelleke; van Grotel, Marloes; Patijn, Jacob; van der Weijden, Trudy; van Kleef, Maarten
2016-01-01
There is a general consensus about the need to define and improve the quality of pain treatment facilities. Although guidelines and recommendations to improve the quality of pain practice management have been launched, provision of appropriate pain treatment is inconsistent and the quality of facilities varies widely. The aim of the study was to develop an expert-agreed list of quality indicators applicable to pain treatment facilities. The list was also intended to be used as the basis for a set of criteria for registered status of pain treatment facilities. The University Pain Center Maastricht at the Department of Anesthesiology and Pain Management of the Maastricht University Medical Center conducted a 3-round Delphi study in collaboration with the Board of the Pain Section of the Dutch Society of Anesthesiologists (NVA). Twenty-five quality indicators were selected as relevant to 2 types of pain treatment facilities, pain clinics and pain centers. The final expert-agreed list consisted of 22 quality indicators covering 7 quality domains: supervision, availability of care, staffing level and patient load, quality policy, multidisciplinarity, regionalization, and research and education. This set of quality indicators may facilitate organizational evaluation and improve insight into service quality from the perspectives of patients, pain specialists, and other healthcare professionals. Recommendations for improvements to the current set of quality indicators are made. In 2014 the process of registering pain treatment facilities in the Netherlands started; facilities can register as a pain clinic or pain center. © 2015 World Institute of Pain.
Mapping health outcome measures from a stroke registry to EQ-5D weights
2013-01-01
Purpose To map health outcome related variables from a national register, not part of any validated instrument, with EQ-5D weights among stroke patients. Methods We used two cross-sectional data sets including patient characteristics, outcome variables and EQ-5D weights from the national Swedish stroke register. Three regression techniques were used on the estimation set (n = 272): ordinary least squares (OLS), Tobit, and censored least absolute deviation (CLAD). The regression coefficients for “dressing“, “toileting“, “mobility”, “mood”, “general health” and “proxy-responders” were applied to the validation set (n = 272), and the performance was analysed with mean absolute error (MAE) and mean square error (MSE). Results The number of statistically significant coefficients varied by model, but all models generated consistent coefficients in terms of sign. Mean utility was underestimated in all models (least in OLS) and with lower variation (least in OLS) compared to the observed. The maximum attainable EQ-5D weight ranged from 0.90 (OLS) to 1.00 (Tobit and CLAD). Health states with utility weights <0.5 had greater errors than those with weights ≥0.5 (P < 0.01). Conclusion This study indicates that it is possible to map non-validated health outcome measures from a stroke register into preference-based utilities to study the development of stroke care over time, and to compare with other conditions in terms of utility. PMID:23496957
Ancilla-driven quantum computation for qudits and continuous variables
NASA Astrophysics Data System (ADS)
Proctor, Timothy; Giulian, Melissa; Korolkova, Natalia; Andersson, Erika; Kendon, Viv
2017-05-01
Although qubits are the leading candidate for the basic elements in a quantum computer, there are also a range of reasons to consider using higher-dimensional qudits or quantum continuous variables (QCVs). In this paper, we use a general "quantum variable" formalism to propose a method of quantum computation in which ancillas are used to mediate gates on a well-isolated "quantum memory" register and which may be applied to the setting of qubits, qudits (for d >2 ), or QCVs. More specifically, we present a model in which universal quantum computation may be implemented on a register using only repeated applications of a single fixed two-body ancilla-register interaction gate, ancillas prepared in a single state, and local measurements of these ancillas. In order to maintain determinism in the computation, adaptive measurements via a classical feed forward of measurement outcomes are used, with the method similar to that in measurement-based quantum computation (MBQC). We show that our model has the same hybrid quantum-classical processing advantages as MBQC, including the power to implement any Clifford circuit in essentially one layer of quantum computation. In some physical settings, high-quality measurements of the ancillas may be highly challenging or not possible, and hence we also present a globally unitary model which replaces the need for measurements of the ancillas with the requirement for ancillas to be prepared in states from a fixed orthonormal basis. Finally, we discuss settings in which these models may be of practical interest.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Proctor, Timothy; Giulian, Melissa; Korolkova, Natalia
Although qubits are the leading candidate for the basic elements in a quantum computer, there are also a range of reasons to consider using higher-dimensional qudits or quantum continuous variables (QCVs). In this paper, we use a general “quantum variable” formalism to propose a method of quantum computation in which ancillas are used to mediate gates on a well-isolated “quantum memory” register and which may be applied to the setting of qubits, qudits (for d>2), or QCVs. More specifically, we present a model in which universal quantum computation may be implemented on a register using only repeated applications of amore » single fixed two-body ancilla-register interaction gate, ancillas prepared in a single state, and local measurements of these ancillas. In order to maintain determinism in the computation, adaptive measurements via a classical feed forward of measurement outcomes are used, with the method similar to that in measurement-based quantum computation (MBQC). We show that our model has the same hybrid quantum-classical processing advantages as MBQC, including the power to implement any Clifford circuit in essentially one layer of quantum computation. In some physical settings, high-quality measurements of the ancillas may be highly challenging or not possible, and hence we also present a globally unitary model which replaces the need for measurements of the ancillas with the requirement for ancillas to be prepared in states from a fixed orthonormal basis. In conclusion, we discuss settings in which these models may be of practical interest.« less
Thomson, Annika; Tiihonen, Jari; Miettunen, Jouko; Virkkunen, Matti; Lindberg, Nina
2017-02-01
Aggressive and disruptive behaviours often precede the onset of serious mental illnesses. Fire-setting is a type of crime that is associated with psychotic disorders. The aim of this prospective follow-up study was to investigate if fire-setting performed in adolescence or early adulthood was associated with future diagnoses of schizophrenia or schizoaffective disorder. The consecutive sample consisted of 111 Finnish 15-25-year old males with fire-setting crimes, decreed to a pre-trial forensic psychiatric examination in 1973-1998, and showing no past nor current psychosis at the time of examination. For each firesetter, four age-, gender-, and place of birth-matched controls were randomly selected from the Central Population Register. The subjects were followed until the death of the individual, until they moved abroad, or until the end of 2012. Fourteen firesetters (12.6%) and five controls (1.1%) were diagnosed with either schizophrenia or schizoaffective disorder later in life, corresponding to a hazard ratio of 12.5. The delay between the fire-setting offense and the future diagnosis was on average nearly 10 years. Young male offenders undergoing a forensic psychiatric examination because of fire-setting crimes had a significant propensity for schizophrenia and schizoaffective disorder. Accurate assessments should be made both during imprisonment and later in life to detect possible psychotic signs in these individuals.
24 CFR 1715.50 - Advertising disclaimers; subdivisions registered and effective with HUD.
Code of Federal Regulations, 2010 CFR
2010-04-01
... statement may be set in type of at least six point font. (c) This disclaimer statement need not appear on... at the bottom of the front page. The disclaimer statement shall be set in type of at least ten point font. Obtain the Property Report required by Federal law and read it before signing anything. No...
1968-01-01
which forms a conducting medium between the electrodes of a dry cell , storage cell , or electrolytic capacitor. ELECTROMAGNETIC FIELD - A mlagnetic...Dry cel batteries. (2) Vehicular batteries. (3) Hand generators. (4) Gas engine generators. (5) Wet cell batteries. 2-5. NETTING TWO RADIO SETS: To net...1600 meters Power output .. .. .. ..... ..... ..... 5watt Power source. .. .. .. ..... ...... ... dry cell battery flA-270/U Battery lift
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd, A.; Perry, M.; Smith, B.
2014-12-01
In this report, we use smart meter data to analyze specific actions, behaviors, and characteristics that drive energy savings in a BB program. Specifically, we examine a Home Energy Report (HER) program. These programs typically obtain 1% to 3% annual savings, and recent studies have shown hourly savings of between 0.5% and 3%.1 But what is driving these savings? What types of households tend to be “high-savers,” and what behaviors are they adopting? There are several possibilities: one-time behaviors (e.g., changing thermostat settings), reoccurring habitual behaviors (e.g., turning off lights), and equipment purchase behaviors (e.g., energy efficient appliances); these maymore » vary across households, regions, and over time.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd, Annika; Perry, Michael; Smith, Brian
2014-12-01
In this report, we use smart meter data to analyze specific actions, behaviors, and characteristics that drive energy savings in a behavior-based (BB) program. Specifically, we examine a Home Energy Report (HER) program. These programs typically obtain 1% to 3% annual savings, and recent studies have shown hourly savings of between 0.5% and 3%. But what is driving these savings? What types of households tend to be “high-savers”, and what behaviors are they adopting? There are several possibilities: one-time behaviors (e.g., changing thermostat settings); reoccurring habitual behaviors (e.g., turning off lights); and equipment purchase behaviors (e.g., energy efficient appliances), andmore » these may vary across households, regions, and over time.« less
"Theory Becoming Alive": The Learning Transition Process of Newly Graduated Nurses in Canada.
Nour, Violet; Williams, Anne M
2018-01-01
Background Newly graduated nurses often encounter a gap between theory and practice in clinical settings. Although this has been the focus of considerable research, little is known about the learning transition process. Purpose The purpose of this study was to explore the experiences of newly graduated nurses in acute healthcare settings within Canada. This study was conducted to gain a greater understanding of the experiences and challenges faced by graduates. Methods Grounded theory method was utilized with a sample of 14 registered nurses who were employed in acute-care settings. Data were collected using in-depth interviews. Constant comparative analysis was used to analyze data. Results Findings revealed a core category, "Theory Becoming Alive," and four supporting categories: Entry into Practice, Immersion, Committing, and Evolving. Theory Becoming Alive described the process of new graduate nurses' clinical learning experiences as well as the challenges that they encountered in clinical settings after graduating. Conclusions This research provides a greater understanding of learning process of new graduate nurses in Canada. It highlights the importance of providing supportive environments to assist new graduate nurses to develop confidence as independent registered nurses in clinical areas. Future research directions as well as supportive educational strategies are described.
NASA Astrophysics Data System (ADS)
Woodford, Curtis; Yartsev, Slav; Van Dyk, Jake
2007-08-01
This study aims to investigate the settings that provide optimum registration accuracy when registering megavoltage CT (MVCT) studies acquired on tomotherapy with planning kilovoltage CT (kVCT) studies of patients with lung cancer. For each experiment, the systematic difference between the actual and planned positions of the thorax phantom was determined by setting the phantom up at the planning isocenter, generating and registering an MVCT study. The phantom was translated by 5 or 10 mm, MVCT scanned, and registration was performed again. A root-mean-square equation that calculated the residual error of the registration based on the known shift and systematic difference was used to assess the accuracy of the registration process. The phantom study results for 18 combinations of different MVCT/kVCT registration options are presented and compared to clinical registration data from 17 lung cancer patients. MVCT studies acquired with coarse (6 mm), normal (4 mm) and fine (2 mm) slice spacings could all be registered with similar residual errors. No specific combination of resolution and fusion selection technique resulted in a lower residual error. A scan length of 6 cm with any slice spacing registered with the full image fusion selection technique and fine resolution will result in a low residual error most of the time. On average, large corrections made manually by clinicians to the automatic registration values are infrequent. Small manual corrections within the residual error averages of the registration process occur, but their impact on the average patient position is small. Registrations using the full image fusion selection technique and fine resolution of 6 cm MVCT scans with coarse slices have a low residual error, and this strategy can be clinically used for lung cancer patients treated on tomotherapy. Automatic registration values are accurate on average, and a quick verification on a sagittal MVCT slice should be enough to detect registration outliers.
Development of a Comprehensive Seismic Yield Estimation System for Underground Nuclear Explosions
1993-05-01
Inc. SPOT data are copyrighted by CNES (1986,1987). UNIX is a registered trademark of AT&T Bell Laboratories. FrameMaker is a registered trademark of...interface to the desktop publishing package FrameMaker , version 3.0 X, which allows the user to generate, edit and print a report of the analysis. Startup...if you’re sure. 3. Logout of UNIX at the console. FrameMaker Instructions FrameMaker version 3.0 X or later must be set up on the Sun work- station as
California's minimum-nurse-staffing legislation and nurses' wages.
Mark, Barbara; Harless, David W; Spetz, Joanne
2009-01-01
In 2004, California became the first state to implement minimum-nurse-staffing ratios in acute care hospitals. We examined the wages of registered nurses (RNs) before and after the legislation was enacted. Using four data sets-the National Sample Survey of Registered Nurses, the Current Population Survey, the National Compensation Survey, and the Occupational Employment Statistics Survey-we found that from 2000 through 2006, RNs in California metropolitan areas experienced real wage growth as much as twelve percentage points higher than the growth in the wages of nurses employed in metropolitan areas outside of California.
NASA Technical Reports Server (NTRS)
Goldman, Benjamin D.; Dowell, Earl H.; Scott, Robert C.
2015-01-01
Conical shell theory and a supersonic potential flow aerodynamic theory are used to study the nonlinear pressure buckling and aeroelastic limit cycle behavior of the thermal protection system for NASA's Hypersonic Inflatable Aerodynamic Decelerator. The structural model of the thermal protection system consists of an orthotropic conical shell of the Donnell type, resting on several circumferential elastic supports. Classical Piston Theory is used initially for the aerodynamic pressure, but was found to be insufficient at low supersonic Mach numbers. Transform methods are applied to the convected wave equation for potential flow, and a time-dependent aerodynamic pressure correction factor is obtained. The Lagrangian of the shell system is formulated in terms of the generalized coordinates for all displacements and the Rayleigh-Ritz method is used to derive the governing differential-algebraic equations of motion. Aeroelastic limit cycle oscillations and buckling deformations are calculated in the time domain using a Runge-Kutta method in MATLAB. Three conical shell geometries were considered in the present analysis: a 3-meter diameter 70 deg. cone, a 3.7-meter 70 deg. cone, and a 6-meter diameter 70 deg. cone. The 6-meter configuration was loaded statically and the results were compared with an experimental load test of a 6-meter HIAD. Though agreement between theoretical and experimental strains was poor, the circumferential wrinkling phenomena observed during the experiments was captured by the theory and axial deformations were qualitatively similar in shape. With Piston Theory aerodynamics, the nonlinear flutter dynamic pressures of the 3-meter configuration were in agreement with the values calculated using linear theory, and the limit cycle amplitudes were generally on the order of the shell thickness. The effect of axial tension was studied for this configuration, and increasing tension was found to decrease the limit cycle amplitudes when the circumferential elastic supports were neglected, but resulted in more complex behavior when the supports were included. The nominal flutter dynamic pressure of the 3.7-meter configuration was significantly lower than that of the 3-meter, and it was found that two sets of natural modes coalesce to flutter modes near the same dynamic pressure. This resulted in a significant drop in the limit cycle frequencies at higher dynamic pressures, where the flutter mode with the lower frequency becomes more critical. Pre-buckling pressure loads and the aerodynamic pressure correction factor were studied for all geometries, and these effects resulted in significantly lower flutter boundaries compared with Piston Theory alone. The maximum dynamic pressure predicted by aerodynamic simulations of a proposed 3.7-meter HIAD vehicle was still lower than any of the calculated flutter dynamic pressures, suggesting that aeroelastic effects for this vehicle are of little concern.
Off-set stabilizer for comparator output
Lunsford, James S.
1991-01-01
A stabilized off-set voltage is input as the reference voltage to a comparator. In application to a time-interval meter, the comparator output generates a timing interval which is independent of drift in the initial voltage across the timing capacitor. A precision resistor and operational amplifier charge a capacitor to a voltage which is precisely offset from the initial voltage. The capacitance of the reference capacitor is selected so that substantially no voltage drop is obtained in the reference voltage applied to the comparator during the interval to be measured.
Hogervorst, Maarten A.; Pinkus, Alan R.
2016-01-01
The fusion and enhancement of multiband nighttime imagery for surveillance and navigation has been the subject of extensive research for over two decades. Despite the ongoing efforts in this area there is still only a small number of static multiband test images available for the development and evaluation of new image fusion and enhancement methods. Moreover, dynamic multiband imagery is also currently lacking. To fill this gap we present the TRICLOBS dynamic multi-band image data set containing sixteen registered visual (0.4–0.7μm), near-infrared (NIR, 0.7–1.0μm) and long-wave infrared (LWIR, 8–14μm) motion sequences. They represent different military and civilian surveillance scenarios registered in three different scenes. Scenes include (military and civilian) people that are stationary, walking or running, or carrying various objects. Vehicles, foliage, and buildings or other man-made structures are also included in the scenes. This data set is primarily intended for the development and evaluation of image fusion, enhancement and color mapping algorithms for short-range surveillance applications. The imagery was collected during several field trials with our newly developed TRICLOBS (TRI-band Color Low-light OBServation) all-day all-weather surveillance system. This system registers a scene in the Visual, NIR and LWIR part of the electromagnetic spectrum using three optically aligned sensors (two digital image intensifiers and an uncooled long-wave infrared microbolometer). The three sensor signals are mapped to three individual RGB color channels, digitized, and stored as uncompressed RGB (false) color frames. The TRICLOBS data set enables the development and evaluation of (both static and dynamic) image fusion, enhancement and color mapping algorithms. To allow the development of realistic color remapping procedures, the data set also contains color photographs of each of the three scenes. The color statistics derived from these photographs can be used to define color mappings that give the multi-band imagery a realistic color appearance. PMID:28036328
Toet, Alexander; Hogervorst, Maarten A; Pinkus, Alan R
2016-01-01
The fusion and enhancement of multiband nighttime imagery for surveillance and navigation has been the subject of extensive research for over two decades. Despite the ongoing efforts in this area there is still only a small number of static multiband test images available for the development and evaluation of new image fusion and enhancement methods. Moreover, dynamic multiband imagery is also currently lacking. To fill this gap we present the TRICLOBS dynamic multi-band image data set containing sixteen registered visual (0.4-0.7μm), near-infrared (NIR, 0.7-1.0μm) and long-wave infrared (LWIR, 8-14μm) motion sequences. They represent different military and civilian surveillance scenarios registered in three different scenes. Scenes include (military and civilian) people that are stationary, walking or running, or carrying various objects. Vehicles, foliage, and buildings or other man-made structures are also included in the scenes. This data set is primarily intended for the development and evaluation of image fusion, enhancement and color mapping algorithms for short-range surveillance applications. The imagery was collected during several field trials with our newly developed TRICLOBS (TRI-band Color Low-light OBServation) all-day all-weather surveillance system. This system registers a scene in the Visual, NIR and LWIR part of the electromagnetic spectrum using three optically aligned sensors (two digital image intensifiers and an uncooled long-wave infrared microbolometer). The three sensor signals are mapped to three individual RGB color channels, digitized, and stored as uncompressed RGB (false) color frames. The TRICLOBS data set enables the development and evaluation of (both static and dynamic) image fusion, enhancement and color mapping algorithms. To allow the development of realistic color remapping procedures, the data set also contains color photographs of each of the three scenes. The color statistics derived from these photographs can be used to define color mappings that give the multi-band imagery a realistic color appearance.
Malgorzata Kasperska Henryk Bunka
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The MarCo Engineering Company Ltd. has its registered seat at Gdynia and was established in 1990. We are the exclusive representative for Poland of the world`s renowned manufacturers of heat distribution network products; Through six subsidiaries (Gdynia, Warsaw, Wroclaw, Cracow, Gliwice and Lublin) and our dealers` network all over Poland the following products and services are offered: (1) automatic control systems for heating and air conditioning; (2) a supervisory remote control system for heat distribution centers; (3) compensating devices for central heating and household hot water installations; (4) radiator thermostatic valves; (5) Meinecke water meters; (6) thermal energy counters; (6)more » a remote calorimeter data reading system SIOX; (7) an electronic central heating costs sharing system - GT-15; (8) compact thermal stations; and (9) compact and pipe exchangers. The modern, high standard devices offered have achieved much success on the Polish market.« less
NASA Technical Reports Server (NTRS)
1977-01-01
Integrated set of manual procedures, computer programs, and graphic devices processes multispectral scanner data from orbiting Landsat into precisely registered and formatted maps of surface water and other resources at variety of scales, sheet formats, and tick intervals.
Environmental Impact Statement Filing Guidance
Describes how to submit an environmental impact statement through the e-NEPA electronic submission system. Describes how EPA submits a notice of availability in to the Federal Register and how the comment time period if set forth.
Code of Federal Regulations, 2010 CFR
2010-10-01
... NANC. (p) The term Registered Internet-based TRS User has the meaning set forth in 47 CFR 64.601. (q... part of the public switched network that, among other things: (1) Interconnects to an SCP and sends to...
Closure plan for Corrective Action Unit 109: U-2bu subsidence crater, Nevada Test Site, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-03-01
The U-2bu subsidence crater, Corrective Action Unit 109, will be closed in accordance with the Resource Conservation and Recovery Act, the Nevada Division of Environmental Protection operational permit, and the Federal Facility Agreement and Consent Order. The U-2bu subsidence crater is located in Area 2 of the Nevada Test Site. It was created in 1971 by an underground nuclear test with the name Miniata. The crater has a diameter of 288 meters (944 feet) and an approximate depth of 35 meters (115 feet). Based on the results of the analyses reported in the site characterization report, the only constituents ofmore » concern in the U-2bu subsidence crater include leachable lead and total petroleum hydrocarbons. Closure activities will include the excavation and disposal of impacted soil from the top of the crater. Upon completion of excavation, verification samples will be collected to show that the leachable lead has been removed to concentrations below the regulatory action level. After sample results show that the lead has been removed, the excavated area will be backfilled and a soil flood diversion berm will be constructed as a best management practice. An independent registered professional engineer will certify the site was closed following the approved Closure Plan. Post-closure care is not warranted for this site because closure activities will involve removal of the Resource Conservation and Recovery Act constituents of concern.« less
NASA Astrophysics Data System (ADS)
Krämer, Sebastian G. M.; Wiesent, Benjamin; Müller, Mathias S.; Puente León, Fernando; Méndez Hernández, Yarú
2008-04-01
Wind turbine blades are made of composite materials and reach a length of more than 42 meters. Developments for modern offshore turbines are working on about 60 meters long blades. Hence, with the increasing height of the turbines and the remote locations of the structures, health monitoring systems are becoming more and more important. Therefore, fiber-optic sensor systems are well-suited, as they are lightweight, immune against electromagnetic interference (EMI), and as they can be multiplexed. Based on two separately existing concepts for strain measurements and lightning detection on wind turbines, a fused system is presented. The strain measurement system is based on a reflective fiber-Bragg-grating (FBG) network embedded in the composite structure of the blade. For lightning detection, transmissive &fiber-optic magnetic field sensors based on the Faraday effect are used to register the lightning parameters and estimate the impact point. Hence, an existing lightning detection system will be augmented, due to the fusion, by the capability to measure strain, temperature and vibration. Load, strain, temperature and impact detection information can be incorporated into the turbine's monitoring or SCADA system and remote controlled by operators. Data analysis techniques allow dynamic maintenance scheduling to become a reality, what is of special interest for the cost-effective maintenance of large offshore or badly attainable onshore wind parks. To prove the feasibility of this sensor fusion on one optical fiber, interferences between both sensor systems are investigated and evaluated.
Ground-Cover Measurements: Assessing Correlation Among Aerial and Ground-Based Methods
NASA Astrophysics Data System (ADS)
Booth, D. Terrance; Cox, Samuel E.; Meikle, Tim; Zuuring, Hans R.
2008-12-01
Wyoming’s Green Mountain Common Allotment is public land providing livestock forage, wildlife habitat, and unfenced solitude, amid other ecological services. It is also the center of ongoing debate over USDI Bureau of Land Management’s (BLM) adjudication of land uses. Monitoring resource use is a BLM responsibility, but conventional monitoring is inadequate for the vast areas encompassed in this and other public-land units. New monitoring methods are needed that will reduce monitoring costs. An understanding of data-set relationships among old and new methods is also needed. This study compared two conventional methods with two remote sensing methods using images captured from two meters and 100 meters above ground level from a camera stand (a ground, image-based method) and a light airplane (an aerial, image-based method). Image analysis used SamplePoint or VegMeasure software. Aerial methods allowed for increased sampling intensity at low cost relative to the time and travel required by ground methods. Costs to acquire the aerial imagery and measure ground cover on 162 aerial samples representing 9000 ha were less than 3000. The four highest correlations among data sets for bare ground—the ground-cover characteristic yielding the highest correlations (r)—ranged from 0.76 to 0.85 and included ground with ground, ground with aerial, and aerial with aerial data-set associations. We conclude that our aerial surveys are a cost-effective monitoring method, that ground with aerial data-set correlations can be equal to, or greater than those among ground-based data sets, and that bare ground should continue to be investigated and tested for use as a key indicator of rangeland health.
Generation of the global cloud free data set of MODIS
NASA Astrophysics Data System (ADS)
Oguro, Y.; Tsuchiya, K.
To extract temporal change of the land cover from remotely sensed data from space the generation of the reliable cloud free data set is the first priority item With the objectives of generating accurate global basic data and to find the effects of spectral and spatial resolution differences and observation time an attempt is made to generate reliable global cloud free data set of Terra and Aqua MODIS utilizing personal computers Out of 36 bands seven bands with similar spectral features to those of Landsat TM i e Band 1 through 7 are selected These bands cover the most important spectra to derive landcover features The procedure of the data set generation is as follows 1 Download the global Terra and Aqua MODIS day time data MOD02 Level-1B Calibrated Geolocation Data Set of 250 meter Band 1 and 2 and 500 meter Band 3 through 7 resolution from NASA web site 2 Separate the data into several BSQ Band SeQuential image and several text geolocation information of pixels files 3 The geolocation information is given to the pixels of several kms interval Based on the information resampling of the data are made at 1 2 and 1 4 degrees intervals of latitude and longitude thus the resampled pixels are distributed in the latitude and longitudinal axis plane at 1 4 degrees high resolution and 1 2 degrees low resolution intervals 4 A global data for one day is composed 5 Compute NDVI for each pixel 6 Compare the value of NDVI of successive days and keep the larger NDVI At the same time keep the values of each band of the day of the larger
Microcomputer based controller for the Langley 0.3-meter Transonic Cryogenic Tunnel
NASA Technical Reports Server (NTRS)
Balakrishna, S.; Kilgore, W. Allen
1989-01-01
Flow control of the Langley 0.3-meter Transonic Cryogenic Tunnel (TCT) is a multivariable nonlinear control problem. Globally stable control laws were generated to hold tunnel conditions in the presence of geometrical disturbances in the test section and precisely control the tunnel states for small and large set point changes. The control laws are mechanized as four inner control loops for tunnel pressure, temperature, fan speed, and liquid nitrogen supply pressure, and two outer loops for Mach number and Reynolds number. These integrated control laws have been mechanized on a 16-bit microcomputer working on DOS. This document details the model of the 0.3-m TCT, control laws, microcomputer realization, and its performance. The tunnel closed loop responses to small and large set point changes were presented. The controller incorporates safe thermal management of the tunnel cooldown based on thermal restrictions. The controller was shown to provide control of temperature to + or - 0.2K, pressure to + or - 0.07 psia, and Mach number to + or - 0.002 of a given set point during aerodynamic data acquisition in the presence of intrusive geometrical changes like flexwall movement, angle-of-attack changes, and drag rake traverse. The controller also provides a new feature of Reynolds number control. The controller provides a safe, reliable, and economical control of the 0.3-m TCT.
Sloane, Philip D; Mitchell, C Madeline; Weisman, Gerald; Zimmerman, Sheryl; Foley, Kristie M Long; Lynn, Mary; Calkins, Margaret; Lawton, M Powell; Teresi, Jeanne; Grant, Leslie; Lindeman, David; Montgomery, Rhonda
2002-03-01
To develop an observational instrument that describes the ability of physical environments of institutional settings to address therapeutic goals for persons with dementia. A National Institute on Aging workgroup identified and subsequently revised items that evaluated exit control, maintenance, cleanliness, safety, orientation/cueing, privacy, unit autonomy, outdoor access, lighting, noise, visual/tactile stimulation, space/seating, and familiarity/homelikeness. The final instrument contains 84 discrete items and one global rating. A summary scale, the Special Care Unit Environmental Quality Scale (SCUEQS), consists of 18 items. Lighting items were validated using portable light meters. Concurrent criterion validation compared SCUEQS scores with the Professional Environmental Assessment Protocol (PEAP). Interrater kappa statistics for 74% of items were above.60. For another 10% of items, kappas could not be calculated due to empty cells, but interrater agreement was above 80%. The SCUEQS demonstrated an interrater reliability of.93, a test--retest reliability of.88, and an internal consistency of.81--.83. Light meter ratings correlated significantly with the Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH) lighting items (r =.29--.38, p =.01--.04), and the SCUEQS correlated significantly with global PEAP ratings (r =.52, p <.01). The TESS-NH efficiently assesses discrete elements of the physical environment and has strong reliability and validity. The SCUEQS provides a quantitative measure of environmental quality in institutional settings.
Layout design in order to improve efficiency in manufacturing
NASA Astrophysics Data System (ADS)
Siregar, I.; Tarigan, U.; Nasution, T. H.
2018-02-01
This research was conducted at the company that produces bobbins and ream type cigarette paper. Problems that found on the production process is the back and forth (back tracking) movement. Back and forth (back tracking) movement extending the total distance moved by the material and increase the total moment of transfer materials thus reducing the efficiency of the transfer of materials in the production process. The purpose of this study is to give design for the layout of production facilities in the company, so that the expected production produced by the company can reach the targets set by the management company. The method used in this research is the Graph-Based Construction and Travel Chart Method. The results of the analysis of the proposed layout with Graph-Based Construction was selected with a total value that is equal to the moment of transfer of 780 758 m / year. This result is better than the actual layout in the amount of 1,021,038.12 meters / year and the results of the method Travel Alternative Chart I of 826.236,60 meters/year, Alternative II of 1.004.433,56 meters / year, and Alternative III for 828,467.12 meters/year. The design layout of Graph-Based Construction material increases the transfer efficiency for 23.53%. With this layout proposal, expected production capacity will be increased along with the shortening of the distance of the displacement that must be passed by the material to be processed.
NASA Astrophysics Data System (ADS)
Fairchild, A.; Chirayath, V.; Gladen, R.; McDonald, A.; Lim, Z.; Chrysler, M.; Koymen, A.; Weiss, A.
Simion 8.1®simulations were used to determine the energy resolution of a 1 meter long Time of Flight Positron annihilation induced Auger Electron Spectrometer (TOF-PAES). The spectrometer consists of: 1. a magnetic gradient section used to parallelize the electrons leaving the sample along the beam axis, 2. an electric field free time of flight tube and 3. a detection section with a set of ExB plates that deflect electrons exiting the TOF tube into a Micro-Channel Plate (MCP). Simulations of the time of flight distribution of electrons emitted according to a known secondary electron emission distribution, for various sample biases, were compared to experimental energy calibration peaks and found to be in excellent agreement. The TOF spectra at the highest sample bias was used to determine the timing resolution function describing the timing spread due to the electronics. Simulations were then performed to calculate the energy resolution at various electron energies in order to deconvolute the combined influence of the magnetic field parallelizer, the timing resolution, and the voltage gradient at the ExB plates. The energy resolution of the 1m TOF-PAES was compared to a newly constructed 3 meter long system. The results were used to optimize the geometry and the potentials of the ExB plates for obtaining the best energy resolution. This work was supported by NSF Grant NSF Grant No. DMR 1508719 and DMR 1338130.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romero-Gomez, P.; Harding, S. F.; Richmond, M. C.
2017-01-01
Standards provide recommendations for best practices when installing current meters to measure fluid flow in closed conduits. A central guideline requires the velocity distribution to be regular and the flow steady. Because of the nature of the short converging intakes typical of low-head hydroturbines, these assumptions may be invalid if current meters are intended to be used to estimate discharge. Usual concerns are (1) the effects of the number of devices, (2) the sampling location and (3) the high turbulence caused by blockage from submersible traveling screens usually deployed for safe downstream fish passage. These three effects were examined inmore » the present study by using 3D simulated flow fields in both steady-state and transient modes. In the process of describing an application at an existing hydroturbine intake at Ice Harbor Dam, the present work outlined the methods involved, which combined computational fluid dynamics, laboratory measurements in physical models of the hydroturbine, and current meter performance evaluations in experimental settings. The main conclusions in this specific application were that a steady-state flow field sufficed to determine the adequate number of meters and their location, and that both the transverse velocity and turbulence intensity had a small impact on estimate errors. However, while it may not be possible to extrapolate these findings to other field conditions and measuring devices, the study laid out a path to conduct similar assessments in other applications.« less
Duc, Sebastien; Villerius, Vincent; Bertucci, William; Grappe, Frederic
2007-09-01
The ErgomoPro (EP) is a power meter that measures power output (PO) during outdoor and indoor cycling via 2 optoelectronic sensors located in the bottom bracket axis. The aim of this study was to determine the validity and the reproducibility of the EP compared with the SRM crank set and Powertap hub (PT). The validity of the EP was tested in the laboratory during 8 submaximal incremental tests (PO: 100 to 400 W), eight 30-min submaximal constant-power tests (PO = 180 W), and 8 sprint tests (PO > 750 W) and in the field during 8 training sessions (time: 181 +/- 73 min; PO: approximately 140 to 160 W). The reproducibility was assessed by calculating the coefficient of PO variation (CV) during the submaximal incremental and constant tests. The EP provided a significantly higher PO than the SRM and PT during the submaximal incremental test: The mean PO differences were +6.3% +/- 2.5% and +11.1% +/- 2.1% respectively. The difference was greater during field training sessions (+12.0% +/- 5.7% and +16.5% +/- 5.9%) but lower during sprint tests (+1.6% +/- 2.5% and +3.2% +/- 2.7%). The reproducibility of the EP is lower than those of the SRM and PT (CV = 4.1% +/- 1.8%, 1.9% +/- 0.4%, and 2.1% +/- 0.8%, respectively). The EP power meter appears less valid and reliable than the SRM and PT systems.
Balsalobre-Fernández, Carlos; Tejero-González, Carlos Mª; del Campo-Vecino, Juan; Alonso-Curiel, Dionisio
2013-01-01
The aim of this study was to determine the effects of a power training cycle on maximum strength, maximum power, vertical jump height and acceleration in seven high-level 400-meter hurdlers subjected to a specific training program twice a week for 10 weeks. Each training session consisted of five sets of eight jump-squats with the load at which each athlete produced his maximum power. The repetition maximum in the half squat position (RM), maximum power in the jump-squat (W), a squat jump (SJ), countermovement jump (CSJ), and a 30-meter sprint from a standing position were measured before and after the training program using an accelerometer, an infra-red platform and photo-cells. The results indicated the following statistically significant improvements: a 7.9% increase in RM (Z=−2.03, p=0.021, δc=0.39), a 2.3% improvement in SJ (Z=−1.69, p=0.045, δc=0.29), a 1.43% decrease in the 30-meter sprint (Z=−1.70, p=0.044, δc=0.12), and, where maximum power was produced, a change in the RM percentage from 56 to 62% (Z=−1.75, p=0.039, δc=0.54). As such, it can be concluded that strength training with a maximum power load is an effective means of increasing strength and acceleration in high-level hurdlers. PMID:23717361
Balsalobre-Fernández, Carlos; Tejero-González, Carlos M; Del Campo-Vecino, Juan; Alonso-Curiel, Dionisio
2013-03-01
The aim of this study was to determine the effects of a power training cycle on maximum strength, maximum power, vertical jump height and acceleration in seven high-level 400-meter hurdlers subjected to a specific training program twice a week for 10 weeks. Each training session consisted of five sets of eight jump-squats with the load at which each athlete produced his maximum power. The repetition maximum in the half squat position (RM), maximum power in the jump-squat (W), a squat jump (SJ), countermovement jump (CSJ), and a 30-meter sprint from a standing position were measured before and after the training program using an accelerometer, an infra-red platform and photo-cells. The results indicated the following statistically significant improvements: a 7.9% increase in RM (Z=-2.03, p=0.021, δc=0.39), a 2.3% improvement in SJ (Z=-1.69, p=0.045, δc=0.29), a 1.43% decrease in the 30-meter sprint (Z=-1.70, p=0.044, δc=0.12), and, where maximum power was produced, a change in the RM percentage from 56 to 62% (Z=-1.75, p=0.039, δc=0.54). As such, it can be concluded that strength training with a maximum power load is an effective means of increasing strength and acceleration in high-level hurdlers.
2013-01-01
Background In Germany, hospitals can deliver data from patients with pelvic fractures selectively or twofold to two different trauma registries, i.e. the German Pelvic Injury Register (PIR) and the TraumaRegister DGU® (TR). Both registers are anonymous and differ in composition and content. We describe the methodological approach of linking these registries and reidentifying twofold documented patients. The aim of the approach is to create an intersection set that benefit from complementary data of each registry, respectively. Furthermore, the concordance of data entry of some clinical variables entered in both registries was evaluated. Methods PIR (4,323 patients) and TR (34,134 patients) data from 2004-2009 were linked together by using a specific match code including code of the trauma department, dates of admission and discharge, patient’s age, and sex. Data entry concordance was evaluated using haemoglobin and blood pressure levels at emergency department arrival, Injury Severity Score (ISS), and mortality. Results Altogether, 420 patients were identified as documented in both data sets. Linkage rates for the intersection set were 15.7% for PIR and 44.4% for TR. Initial fluid management for different Tile/OTA types of pelvic ring fractures and the patient’s posttraumatic course, including intensive care unit data, were now available for the PIR population. TR is benefiting from clinical use of the Tile/OTA classification and from correlation with the distinct entity “complex pelvic injury.” Data entry verification showed high concordance for the ISS and mortality, whereas initial haemoglobin and blood pressure data showed significant differences, reflecting inconsistency at the data entry level. Conclusions Individually, the PIR and the TR reflect a valid source for documenting injured patients, although the data reflect the emphasis of the particular registry. Linking the two registries enabled new insights into care of multiple-trauma patients with pelvic fractures even when linkage rates were poor. Future considerations and development of the registries should be done in close bilateral consultation with the aim of benefiting from complementary data and improving data concordance. It is also conceivable to integrate individual modules, e.g. a pelvic fracture module, into the TR likewise a modular system in the future. PMID:23496832
McMullan, Miriam; Jones, Ray; Lea, Susan
2010-04-01
This paper is a report of a correlational study of the relations of age, status, experience and drug calculation ability to numerical ability of nursing students and Registered Nurses. Competent numerical and drug calculation skills are essential for nurses as mistakes can put patients' lives at risk. A cross-sectional study was carried out in 2006 in one United Kingdom university. Validated numerical and drug calculation tests were given to 229 second year nursing students and 44 Registered Nurses attending a non-medical prescribing programme. The numeracy test was failed by 55% of students and 45% of Registered Nurses, while 92% of students and 89% of nurses failed the drug calculation test. Independent of status or experience, older participants (> or = 35 years) were statistically significantly more able to perform numerical calculations. There was no statistically significant difference between nursing students and Registered Nurses in their overall drug calculation ability, but nurses were statistically significantly more able than students to perform basic numerical calculations and calculations for solids, oral liquids and injections. Both nursing students and Registered Nurses were statistically significantly more able to perform calculations for solids, liquid oral and injections than calculations for drug percentages, drip and infusion rates. To prevent deskilling, Registered Nurses should continue to practise and refresh all the different types of drug calculations as often as possible with regular (self)-testing of their ability. Time should be set aside in curricula for nursing students to learn how to perform basic numerical and drug calculations. This learning should be reinforced through regular practice and assessment.
VR-Planets : a 3D immersive application for real-time flythrough images of planetary surfaces
NASA Astrophysics Data System (ADS)
Civet, François; Le Mouélic, Stéphane
2015-04-01
During the last two decades, a fleet of planetary probes has acquired several hundred gigabytes of images of planetary surfaces. Mars has been particularly well covered thanks to the Mars Global Surveyor, Mars Express and Mars Reconnaissance Orbiter spacecrafts. HRSC, CTX, HiRISE instruments allowed the computation of Digital Elevation Models with a resolution from hundreds of meters up to 1 meter per pixel, and corresponding orthoimages with a resolution from few hundred of meters up to 25 centimeters per pixel. The integration of such huge data sets into a system allowing user-friendly manipulation either for scientific investigation or for public outreach can represent a real challenge. We are investigating how innovative tools can be used to freely fly over reconstructed landscapes in real time, using technologies derived from the game industry and virtual reality. We have developed an application based on a game engine, using planetary data, to immerse users in real martian landscapes. The user can freely navigate in each scene at full spatial resolution using a game controller. The actual rendering is compatible with several visualization devices such as 3D active screen, virtual reality headsets (Oculus Rift), and android devices.
NASA Astrophysics Data System (ADS)
Singer, Robin; Butler, Douglas M.
1990-07-01
A High Speed Buffer Board (HSBB) was developed for the Vector Measuring Current Meter (VMCM) to implement the transmission of data at 9600 baud over an EIA-485 link. The HSBB significantly extends the VMCM communication functionality, which was previously limited to 300 baud transmission via 20mA current loop or FSK telemetry. The increased speed allows rapid sampling of a large number of current meters on a common cable and the EIA-485 circuitry, which was designed for low power operation, provides a useful multipoint communication method for data transmission over long cable lengths. SAIL protocol (IEEE 997) was utilized to coordinate data transfer by the instruments on a common link. An MC68HC11 microcontroller resides in the VMCM, buffering data it receives at 300 baud from the VMCM UART. In response to a jumper selectable SAIL address, the MC68HC11 offloads the data 9600 baud via EIA-485 to the SAIL controller. Synchronous data collection from many instruments is ensured by the SAIL synoptic set command and an embedded resynchronization/reset command. The low power consumption allows deployments of six months or more with a standard VMCM battery stack.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doris, E.; Busche, S.; Hockett, S.
2009-12-01
The goal of the Minnesota net metering policy is to give the maximum possible encouragement to distributed generation assets, especially solar electric systems (MN 2008). However, according to a published set of best practices (NNEC 2008) that prioritize the maximum development of solar markets within states, the Minnesota policy does not incorporate many of the important best practices that may help other states transform their solar energy markets and increase the amount of grid-connected distributed solar generation assets. Reasons cited include the low system size limit of 40kW (the best practices document recommends a 2 MW limit) and a lackmore » of language protecting generators from additional utility fees. This study was conducted to compare Minnesota's policies to national best practices. It provides an overview of the current Minnesota policy in the context of these best practices and other jurisdictions' net metering policies, as well as a qualitative assessment of the impacts of raising the system size cap within the policy based on the experiences of other states.« less
NASA Astrophysics Data System (ADS)
Nurhakim, I.; Kurniawan, E. B.; Wardhani, D. K.
2018-05-01
Several studies have shown that living close to a park is associated with high levels of happiness. However, there is a possible difference in the level of happiness between living close to a park (0-400 meters radius) compared to living far from the park (400-1.000 meters radius). Therefore, this study aims to compare the influence of Place Attachment on the level of happiness for people living near a park, especially residential parks in some housing areas in Malang City. Place Attachment in this study defined as a bond between an individual and a particular setting. The study demonstrates a positive influence of Place Attachment on the level of happiness of people living near the park. Respondents who live close to a park (R = 0.441; Happiness Level = 97.8%; Average Happiness = 6.833) tend to have a higher level of happiness compared to respondents who live far from a park (R = 0.326; Happiness Level = 69.9%; average Happiness = 4.148). This result shows the urgency to reconsider the provision standard of residential parks in Indonesia which only suggests one residential park for every 1,000 meters radius.
Economic Analysis and Optimal Sizing for behind-the-meter Battery Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Di; Kintner-Meyer, Michael CW; Yang, Tao
This paper proposes methods to estimate the potential benefits and determine the optimal energy and power capacity for behind-the-meter BSS. In the proposed method, a linear programming is first formulated only using typical load profiles, energy/demand charge rates, and a set of battery parameters to determine the maximum saving in electric energy cost. The optimization formulation is then adapted to include battery cost as a function of its power and energy capacity in order to capture the trade-off between benefits and cost, and therefore to determine the most economic battery size. Using the proposed methods, economic analysis and optimal sizingmore » have been performed for a few commercial buildings and utility rate structures that are representative of those found in the various regions of the Continental United States. The key factors that affect the economic benefits and optimal size have been identified. The proposed methods and case study results cannot only help commercial and industrial customers or battery vendors to evaluate and size the storage system for behind-the-meter application, but can also assist utilities and policy makers to design electricity rate or subsidies to promote the development of energy storage.« less
High-Resolution Digital Terrain Models of the Sacramento/San Joaquin Delta Region, California
Coons, Tom; Soulard, Christopher E.; Knowles, Noah
2008-01-01
The U.S. Geological Survey (USGS) Western Region Geographic Science Center, in conjunction with the USGS Water Resources Western Branch of Regional Research, has developed a high-resolution elevation dataset covering the Sacramento/San Joaquin Delta region of California. The elevation data were compiled photogrammically from aerial photography (May 2002) with a scale of 1:15,000. The resulting dataset has a 10-meter horizontal resolution grid of elevation values. The vertical accuracy was determined to be 1 meter. Two versions of the elevation data are available: the first dataset has all water coded as zero, whereas the second dataset has bathymetry data merged with the elevation data. The projection of both datasets is set to UTM Zone 10, NAD 1983. The elevation data are clipped into files that spatially approximate 7.5-minute USGS quadrangles, with about 100 meters of overlap to facilitate combining the files into larger regions without data gaps. The files are named after the 7.5-minute USGS quadrangles that cover the same general spatial extent. File names that include a suffix (_b) indicate that the bathymetry data are included (for example, sac_east versus sac_east_b). These files are provided in ESRI Grid format.
NASA Technical Reports Server (NTRS)
Arvidson, R. E. (Principal Investigator); Guinness, E. A.; Bindschadler, D. L.
1983-01-01
Several digital data sets were registered to a common base map for southern Missouri. These registered data sets were examined in an attempt to improve our understanding of the crustal structure and the relationships between structure and Pb-Zn-Cu, Fe, Mn, and Ba ores in the area. Data included land station reading of gravity, geologic data, and Heat Capacity Mapping Mission (HCMM) images. The HCMM day infrared (IR) images of Missouri displayed linear features, which parallel a newly discovered NW-SE trending Bouguer gravity low. The structural pattern over the gravity low suggests vertical uplift of the low density crust via isostatic readjustment and consequent fracturing of the Paleozoic sedimentary cover. The presence of a gravity low is interesting because rifts are often sites of extensive mineralization. The HCMM thermal data were also examined in conjunction with digital topography, land use, and LANDSAT MSS data to understand the phenomena that produce linears on the HCMM day IR images. Finally, the kinds of information that can be extracted from day-night IR pairs are discussed.
Haasum, Ylva; Fastbom, Johan; Johnell, Kristina
2016-06-01
It has been suggested that depression in Parkinson's Disease (PD) is often unrecognized and undertreated. However, few previous studies have studied the use of antidepressants in a large sample of both home-dwelling and institutionalized elderly persons with PD. We aimed to study the use of antidepressants in older persons using anti-parkinson drugs (APD, used as a proxy for PD), stratified by residential setting. We analyzed individual data on age, sex, residential setting and drug use in over 1.5 million older persons in the Swedish Prescribed Drug Register on 31th of December 2013. Twenty-two percent of the home-dwellers and 50% of the institutionalized elderly persons with APD used antidepressants. Persons with APD had a higher probability of use of any antidepressant compared to persons without APD. A selective serotonin reuptake inhibitor (SSRI) was the most commonly used antidepressants in both settings followed by mirtazapin. The high use of antidepressants among older persons with APD warrants further studies on the quality of treatment of depression in PD. Copyright © 2016 Elsevier Ltd. All rights reserved.
Khalil, Asma; Perry, Helen; Duffy, James; Reed, Keith; Baschat, Ahmet; Deprest, Jan; Hecher, Kurt; Lewi, Liesbeth; Lopriore, Enrico; Oepkes, Dick
2017-07-14
Twin-Twin Transfusion Syndrome (TTTS) is associated with an increased risk of perinatal mortality and morbidity. Several treatment interventions have been described for TTTS, including fetoscopic laser surgery, amnioreduction, septostomy, expectant management, and pregnancy termination. Over the last decade, fetoscopic laser surgery has become the primary treatment. The literature to date reports on many different outcomes, making it difficult to compare results or combine data from individual studies, limiting the value of research to guide clinical practice. With the advent and ongoing development of new therapeutic techniques, this is more important than ever. The development and use of a core outcome set has been proposed to address these issues, prioritising outcomes important to the key stakeholders, including patients. We aim to produce, disseminate, and implement a core outcome set for TTTS. An international steering group has been established to oversee the development of this core outcome set. This group includes healthcare professionals, researchers and patients. A systematic review is planned to identify previously reported outcomes following treatment for TTTS. Following completion, the identified outcomes will be evaluated by stakeholders using an international, multi-perspective online modified Delphi method to build consensus on core outcomes. This method encourages the participants towards consensus 'core' outcomes. All key stakeholders will be invited to participate. The steering group will then hold a consensus meeting to discuss results and form a core outcome set to be introduced and measured. Once core outcomes have been agreed, the next step will be to determine how they should be measured, disseminated, and implemented within an international context. The development, dissemination, and implementation of a core outcome set in TTTS will enable its use in future clinical trials, systematic reviews and clinical practice guidelines. This is likely to advance the quality of research studies and their effective use in order to guide clinical practice and improve patient care, maternal, short-term perinatal outcomes and long-term neurodevelopmental outcomes. Core Outcome Measures in Effectiveness Trials (COMET), 921 Registered on July 2016. International Prospective Register of Systematic Reviews (PROSPERO), CRD42016043999 . Registered on 2 August 2016.
77 FR 65939 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-31
... Technology Architecture (VistA) Records-VA'' (79VA19) as set forth in the Federal Register 75 FR 4454. VA is... Health Information Systems and Technology Architecture (VistA) Records-VA ROUTINE USES OF RECORDS...
EPA Regulation of Bed Bug Pesticides
All pesticides must be registered by EPA before being sold and used in the U.S., other than those that rely on a limited set of active ingredients (so-called minimum risk pesticides). EPA reviews for safety and effectiveness.
Administrator Leadership Styles and Their Impact on School Nursing.
Davis, Charles R
2018-01-01
In comparison to other professional staff in an educational based setting, the registered professional school nurse has unique roles, responsibilities, education, training, and scope of practice. In carrying out this unique and specialized role, school nurses operate under a building administrator, the leader of the building and often the immediate supervisor of the school nurse. In addition, many school nurses in small districts are the only registered professional nurse employed by the school. The building administrator's leadership style not only sets the tone for the day-to-day operations in the school but also impacts the school nurse functioning and program implementation. This article reviews the three most common types of leadership styles as defined by Kurt Lewin-laissez-faire, democratic, and coercive/authoritarian-and their potential impact on school nursing practice. In addition, the article provides recommendations for school nurses for successful practice with regard to supervisor leadership styles.
Work force policy perspectives: registered nurses.
Friss, L O
1981-01-01
If the decline in full-time labor force participation by registered nurses in hospitals is to be reversed, the issue of equal pay for comparable work must be addressed. Under pressure for cost containment, policies tend to focus on labor force economics rather than on limitations of services. While the two are interrelated, wage policies must be considered independently. This article describes the network which determines how nurse salaries are set: the relationship between the private sector, the general schedule and the Veteran's Administration. The effects of this system are documented, using testimony from a case in the tenth circuit, as well as comparisons with other reference groups: policemen, teachers, laborers, and VA career fields. The evidence suggests that there is a need for policy intervention. Prime areas for action are the comparability practices by governments, particularly in the areas of classification standards and pay setting. Hospital personnel practices which continue past effects of occupational segregation also should be changed.
NASA Technical Reports Server (NTRS)
Hoffer, R. M. (Principal Investigator); Knowlton, D. J.; Dean, M. E.
1981-01-01
A set of training statistics for the 30 meter resolution simulated thematic mapper MSS data was generated based on land use/land cover classes. In addition to this supervised data set, a nonsupervised multicluster block of training statistics is being defined in order to compare the classification results and evaluate the effect of the different training selection methods on classification performance. Two test data sets, defined using a stratified sampling procedure incorporating a grid system with dimensions of 50 lines by 50 columns, and another set based on an analyst supervised set of test fields were used to evaluate the classifications of the TMS data. The supervised training data set generated training statistics, and a per point Gaussian maximum likelihood classification of the 1979 TMS data was obtained. The August 1980 MSS data was radiometrically adjusted. The SAR data was redigitized and the SAR imagery was qualitatively analyzed.
BOREAS Soils Data over the SSA in Raster Format and AEAC Projection
NASA Technical Reports Server (NTRS)
Knapp, David; Rostad, Harold; Hall, Forrest G. (Editor)
2000-01-01
This data set consists of GIS layers that describe the soils of the BOREAS SSA. The original data were submitted as vector layers that were gridded by BOREAS staff to a 30-meter pixel size in the AEAC projection. These data layers include the soil code (which relates to the soil name), modifier (which also relates to the soil name), and extent (indicating the extent that this soil exists within the polygon). There are three sets of these layers representing the primary, secondary, and tertiary soil characteristics. Thus, there is a total of nine layers in this data set along with supporting files. The data are stored in binary, image format files.
The Effect of Remote Sensor Spatial Resolution in Monitoring U.S. Army Training Maneuver Sites
1990-12-01
THE EFFECT OF REMOTE SENSOR SPATIAL RESOLUTION IN MONITORING U.S. ARMY...Multispectral Scanner with 6.5 meter spatial resolution provided the most effective digital data set for enhancing tank trails. However, this Airborne Scanner...primary objective of this research was to determine the capabilities and limitations of remote sensor systems having different spatial resolutions to
Absorption Spectrum of Phytoplankton Pigments Derived from Hyperspectral Remote-Sensing Reflectance
2004-01-01
For a data set collected around Baja California with chlorophyll-a concentration ((chl-a)) ranging from 0.16 to 11.3 mg/cubic meter, hyperspectral absorption spectra of phytoplankton pigments were independently inverted from hyperspectral remote - sensing reflectance using a newly...potential of using hyperspectral remote sensing to retrieve both chlorophyll-a and other accessory pigments. (7 figures, 47 refs.)
Building information modeling (BIM) approach to the GMT Project
NASA Astrophysics Data System (ADS)
Teran, Jose; Sheehan, Michael; Neff, Daniel H.; Adriaanse, David; Grigel, Eric; Farahani, Arash
2014-07-01
The Giant Magellan Telescope (GMT), one of several next generation Extremely Large Telescopes (ELTs), is a 25.4 meter diameter altitude over azimuth design set to be built at the summit of Cerro Campánas at the Las Campánas Observatory in Chile. The paper describes the use of Building Information Modeling (BIM) for the GMT project.
NASA Astrophysics Data System (ADS)
Tao, Xuemei; He, Yong
2006-09-01
The internal quality of tomato such as acidity and sugar content is important to its taste thus influences the market. The objective of this paper was to demonstrate the feasibility of using a near-infrared spectroscopy (NIRS) to investigate the relationship between sugar content and acidity of tomato and absorption spectra. The N1RS reflectance of nondestructive tomatoes was measured with a Visible/NJR spectrophotometer in 325-1075 nm range. The sugar content and acidity of tomato were obtained with a handhold sugar content meter and a PH meter. The reflectance data set was recorded and analyzed with some mathematic methods. The PLS (Partial least squares) calibration method was developed for converting the NIRS reflectance of tomato into the data which determined the acidity value. BP (Back propagation) neural network was used to set up the relationship between the NIRS reflectance of tomato and sugar content. The acidity values were detected with an accuracy of 9O% and the sugar contents determined by the BP network were also very close to the measurements (coefficient of correlation r2=0.8764). NW spectra analysis would be very useful in the nondestructive internal quality inspecting of tomato.
Development of integral holographic motion pictures
NASA Astrophysics Data System (ADS)
Alexander, P.
1995-02-01
In 1985 Anne-Marie Christakis selected me to make the first pulse holographic feature-fiction movie. Up to that time, the process had only been used for laboratory tests. The running time for the movie was to be 1 minute 20 seconds. Apparently quite long compared with previous tests, but an extremely short time in which to tell a story. I chose the characters of Beauty and the Beast. A lot of time was spent in preparatory work: triple distilling the scenario to get it down to 80 seconds; paintings and masks, and I extracted the music from a suite I had already written in medieval style. The movie was made in 1986 in the laboratory of Professeur Smigielsky, which was located in the Franco-German Defense Research Establishment, at St. Louis in France. Prof. Smigielsky's staff operated all the equipment and Anne-Marie Christakis coordinated everything, as she had done throughout the project. As soon as we arrived at the laboratory, we were told not to look beyond a certain angle towards the laser, otherwise we could be blinded for life. With all that dangerous power however, it was only possible to illuminate a volume for the set of half a meter wide by half a meter deep by one third of a meter high. Such a set gives real meaning to the expression `cramp one's style.' The layout used was, in principle, the same as for making a simple hologram. A pulsed YAG laser was used and each pulse was synchronized with a new frame to be exposed in the camera. When the movie was finished, it was not very bright, and one had to look through a small aperture to view it.
Braeckman, Tessa; Lernout, Tinne; Top, Geert; Paeps, Annick; Roelants, Mathieu; Hoppenbrouwers, Karel; Van Damme, Pierre; Theeten, Heidi
2014-01-09
Infant immunisation coverage in Flanders, Belgium, is monitored through repeated coverage surveys. With the increased use of Vaccinnet, the web-based ordering system for vaccines in Flanders set up in 2004 and linked to an immunisation register, this database could become an alternative to quickly estimate vaccination coverage. To evaluate its current accuracy, coverage estimates generated from Vaccinnet alone were compared with estimates from the most recent survey (2012) that combined interview data with data from Vaccinnet and medical files. Coverage rates from registrations in Vaccinnet were systematically lower than the corresponding estimates obtained through the survey (mean difference 7.7%). This difference increased by dose number for vaccines that require multiple doses. Differences in administration date between the two sources were observed for 3.8-8.2% of registered doses. Underparticipation in Vaccinnet thus significantly impacts on the register-based immunisation coverage estimates, amplified by underregistration of administered doses among vaccinators using Vaccinnet. Therefore, survey studies, despite being labour-intensive and expensive, currently provide more complete and reliable results than register-based estimates alone in Flanders. However, further improvement of Vaccinnet's completeness will likely allow more accurate estimates in the nearby future. Copyright © 2013 Elsevier Ltd. All rights reserved.
Stitzel, Kimberly F
2006-11-01
It is the position of the American Dietetic Association (ADA) that primary prevention is the most effective, affordable course of action for preventing and reducing risk for chronic disease. Registered dietitians and dietetic technicians, registered, are leaders in delivering preventive services in both clinical and community settings, including advocating for funding and inclusion of these services in programs and policy initiatives at local, state, and federal levels. In addition, registered dietitians are leaders in facilitating and participating in research in chronic disease prevention and health promotion. Diet, nutrition, and physical activity are important factors in the promotion and maintenance of good health throughout the life cycle. Cost-effective interventions that produce a change in personal health practices are likely to lead to substantial reductions in the incidence and severity of the leading causes of disease in the United States. In an era of increasing health care expenditures and relative decreases in availability of federal funds, there is increasing demand on health promotion and disease prevention to be economically viable. Through clinical involvement and rigorous participation in research on chronic disease prevention and health promotion, the field of dietetics can lead the way to effectively translate the impact of nutrition on all ages.
Staff perceptions of leadership during implementation of task-shifting in three surgical units.
Henderson, Amanda; Paterson, Karyn; Burmeister, Liz; Thomson, Bernadette; Young, Louise
2013-03-01
Registered nurses are difficult to recruit and retain. Task shifting, which involves reallocation of delegation, can reduce demand for registered nurses. Effective leadership is needed for successful task shifting. This study explored leadership styles of three surgical nurse unit managers. Staff completed surveys before and after the implementation of task shifting. Task shifting involved the introduction of endorsed enrolled nurses (licensed nurses who must practise under registered nurse supervision) to better utilize registered nurses. Implementation of task shifting occurred over 4 months in a 700-bed tertiary hospital, in southeast Queensland, Australia. A facilitator assisted nurse unit managers during implementation. The impact was assessed by comparison of data before (n = 49) and after (n = 72) task shifting from registered nurses and endorsed enrolled nurses (n = 121) who completed the Ward Organization Features Survey. Significant differences in leadership and staff organization subscales across the settings suggest that how change involving task shifting is implemented influences nurses' opinions of leadership. Leadership behaviours of nurse unit managers is a key consideration in managing change such as task shifting. Consistent and clear messages from leaders about practice change are viewed positively by nursing staff. In the short term, incremental change possibly results in staff maintaining confidence in leadership. © 2012 Blackwell Publishing Ltd.
Characterizing user requirements for future land observing satellites
NASA Technical Reports Server (NTRS)
Barker, J. L.; Cressy, P. J.; Schnetzler, C. C.; Salomonson, V. V.
1981-01-01
The objective procedure was developed for identifying probable sensor and mission characteristics for an operational satellite land observing system. Requirements were systematically compiled, quantified and scored by type of use, from surveys of federal, state, local and private communities. Incremental percent increases in expected value of data were estimated for critical system improvements. Comparisons with costs permitted selection of a probable sensor system, from a set of 11 options, with the following characteristics: 30 meter spatial resolution in 5 bands and 15 meters in 1 band, spectral bands nominally at Thematic Mapper (TM) bands 1 through 6 positions, and 2 day data turn around for receipt of imagery. Improvements are suggested for both the form of questions and the procedures for analysis of future surveys in order to provide a more quantitatively precise definition of sensor and mission requirements.
Low altitude temperature and humidity profile data for application to aircraft noise propagation
NASA Technical Reports Server (NTRS)
Connor, A. B.; Copeland, W. L.; Fulbright, D. C.
1975-01-01
A data search of the weather statistics from 11 widely dispersed geographical locations within the continental United States was conducted. The sites, located long both sea-coasts and in the interior, span the northern, southern, and middle latitudes. The weather statistics, retrieved from the records of these 11 sites, consist of two daily observations taken over a 10-year period. The data were sorted with respect to precipitation and surface winds and classified into temperature intervals of 5 C and relative humidity intervals of 10 percent for the lower 1400 meters of the atmosphere. These data were assembled in a statistical format and further classified into altitude increments of 200 meters. The data are presented as sets of tables for each site by season of the year and include both daily observations.
Mid-IR Imaging of Orion BN/KL: Modeling of Physical Conditions and Energy Balance
NASA Technical Reports Server (NTRS)
Gezari, Daniel; Varosi, Frank; Dwek, Eli; Danchi, William C.; Tan, Jonathan; Okumura, Shin-ichiro
2016-01-01
We have modeled two mid-infrared imaging photometry data sets to determine the spatial distribution of physical conditions in the BN/KL (Becklin-Neugebauer / Kleinmann-Low) infrared complex. We observed the BN/KL region using the 10-meter Keck I telescope and the LWS (Living With a Star) in the direct imaging mode, over a 13 inch by 19 inch field . We also modeled images obtained with COMICS (Cooled Mid-Infrared Camera and Spectrometer, Kataza et al. 2000) at the 8.2-meter SUBARU telescope, over a total field of view [which] is 31 inches by 41 inches in a total of nine bands: 7.8, 8.8, 9.7, 10.5, 11.7, 12.4, 18.5, 20.8 and 24.8 microns with 1-micron bandwidth interference filters.
Efficient Ada multitasking on a RISC register window architecture
NASA Technical Reports Server (NTRS)
Kearns, J. P.; Quammen, D.
1987-01-01
This work addresses the problem of reducing context switch overhead on a processor which supports a large register file - a register file much like that which is part of the Berkeley RISC processors and several other emerging architectures (which are not necessarily reduced instruction set machines in the purest sense). Such a reduction in overhead is particularly desirable in a real-time embedded application, in which task-to-task context switch overhead may result in failure to meet crucial deadlines. A storage management technique by which a context switch may be implemented as cheaply as a procedure call is presented. The essence of this technique is the avoidance of the save/restore of registers on the context switch. This is achieved through analysis of the static source text of an Ada tasking program. Information gained during that analysis directs the optimized storage management strategy for that program at run time. A formal verification of the technique in terms of an operational control model and an evaluation of the technique's performance via simulations driven by synthetic Ada program traces are presented.
Ancilla-driven quantum computation for qudits and continuous variables
Proctor, Timothy; Giulian, Melissa; Korolkova, Natalia; ...
2017-05-10
Although qubits are the leading candidate for the basic elements in a quantum computer, there are also a range of reasons to consider using higher-dimensional qudits or quantum continuous variables (QCVs). In this paper, we use a general “quantum variable” formalism to propose a method of quantum computation in which ancillas are used to mediate gates on a well-isolated “quantum memory” register and which may be applied to the setting of qubits, qudits (for d>2), or QCVs. More specifically, we present a model in which universal quantum computation may be implemented on a register using only repeated applications of amore » single fixed two-body ancilla-register interaction gate, ancillas prepared in a single state, and local measurements of these ancillas. In order to maintain determinism in the computation, adaptive measurements via a classical feed forward of measurement outcomes are used, with the method similar to that in measurement-based quantum computation (MBQC). We show that our model has the same hybrid quantum-classical processing advantages as MBQC, including the power to implement any Clifford circuit in essentially one layer of quantum computation. In some physical settings, high-quality measurements of the ancillas may be highly challenging or not possible, and hence we also present a globally unitary model which replaces the need for measurements of the ancillas with the requirement for ancillas to be prepared in states from a fixed orthonormal basis. In conclusion, we discuss settings in which these models may be of practical interest.« less
Nhongo, Dorika; Hendricks, Joyce; Bradshaw, Julie; Bail, Kasia
2018-06-12
Registered nurses (RNs) working in Residential Aged Care Facilities are required to undertake complex management tasks including leading nursing care teams, supervising non-nursing staff, and allocating workloads according to residents' care needs, staff skills and experience. Registered nurses plan, assess, manage medication, evaluate each resident's care, liaise with doctors and allied health professionals and are responsible for evidence-based practice in accordance with the Nursing Standards for Practice (2016). Researchers have commented that effective nurse leadership can improve quality of care, improved resident outcomes and reduce adverse events. The aim of this literature review is to synthesise and analyse the literature pertinent to the RN's competence and confidence to undertake the leadership role when working in residential aged care facilities after-hours and to determine any association of leadership with quality resident outcomes. A review of original research papers based on the structured methodology described by Kable, Pich and Maslin-Prothero (2012). The review was conducted according to the 12-step structured framework by Kable et al. (2012). The search included peer-reviewed papers published between 2002 and 2017 on RN leadership after-hours, factors contributing to or with relationships to nursing leadership. Nineteen papers were found that researched the impact of leadership in aged care settings. The literature review concluded that nursing leadership has been linked to the quality of care and clinical outcomes in the aged care setting. However, RNs in the aged care setting have limited opportunities to develop key leadership competencies and confidence in order to meet the many challenges found in this environment due to lack of access to aged-care-specific leadership education. Minimal publications address the importance of the leadership of after-hours RNs. Results from this literature review will inform future research in this area. Nineteen papers identified the leadership required of RNs in aged care settings. However, limited research investigating the association between nursing leadership and clinical outcomes was found. The findings from this literature review suggest that leadership in the aged care setting may be facilitated through specific educational activities such as RN shadowing shifts, continuing professional development, working with peers and by demonstrating and practising leadership competencies. Based on the literature reviewed, a need for more research in this area is required. Specifically, research into RN leadership, competence and confidence in aged care facilities after-hours is needed. Registered nurses working in the aged care setting after-hours need access to leadership education. Better quality of care, improved resident outcomes and reduced adverse events are associated with sound leadership. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
45 CFR 613.1 - General Provisions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION PRIVACY ACT REGULATIONS § 613.1 General Provisions. This part sets forth the National Science Foundation procedures under... maintained by the National Science Foundation are published in the Federal Register. ...
45 CFR 613.1 - General Provisions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION PRIVACY ACT REGULATIONS § 613.1 General Provisions. This part sets forth the National Science Foundation procedures under... maintained by the National Science Foundation are published in the Federal Register. ...
45 CFR 613.1 - General Provisions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION PRIVACY ACT REGULATIONS § 613.1 General Provisions. This part sets forth the National Science Foundation procedures under... maintained by the National Science Foundation are published in the Federal Register. ...
29 CFR 1990.133 - Publication.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) IDENTIFICATION, CLASSIFICATION, AND REGULATION OF POTENTIAL OCCUPATIONAL CARCINOGENS Priority Setting § 1990.133...) The Secretary shall publish the Priority Lists in the Federal Register at least every six months and... notice requesting information concerning the classification and establishment of priorities for...
Atkins, Salla; Ojajärvi, Ulla; Talola, Nina; Viljamaa, Mervi; Nevalainen, Jaakko; Uitti, Jukka
2017-07-26
Employment protects and fosters health. Occupational health services, particularly in Finland, have a central role in protecting employee health and preventing work ability problems. However, primary care within occupational health services is currently underused in informing preventive activities. This study was designed to assess whether the recording of work ability problems and improvement of follow-up of work-related primary care visits can reduce sickness absences and work disability pensions after 1 year. A pragmatic trial will be conducted using patient electronic registers and registers of the central pensions agency in Finland. Twenty-two occupational health centres will be randomised to intervention and control groups. Intervention units will receive training to improve recording of work ability illnesses in the primary care setting and improved follow-up procedures. The intervention impact will be assessed through examining rates of sickness absence across intervention and control clinics as well as before and after the intervention. The trial will develop knowledge of the intervention potential of primary care for preventing work disability pensions and sickness absence. The use of routine patient registers and pensions registers to assess the outcomes of a randomised controlled trial will bring forward trial methodology, particularly when using register-based data. If successful, the intervention will improve the quality of occupational health care primary care and contribute to reducing work disability. ISRCTN Registry reference number ISRCTN45728263 . Registered on 18 April 2016.
Probabilistic registration of an unbiased statistical shape model to ultrasound images of the spine
NASA Astrophysics Data System (ADS)
Rasoulian, Abtin; Rohling, Robert N.; Abolmaesumi, Purang
2012-02-01
The placement of an epidural needle is among the most difficult regional anesthetic techniques. Ultrasound has been proposed to improve success of placement. However, it has not become the standard-of-care because of limitations in the depictions and interpretation of the key anatomical features. We propose to augment the ultrasound images with a registered statistical shape model of the spine to aid interpretation. The model is created with a novel deformable group-wise registration method which utilizes a probabilistic approach to register groups of point sets. The method is compared to a volume-based model building technique and it demonstrates better generalization and compactness. We instantiate and register the shape model to a spine surface probability map extracted from the ultrasound images. Validation is performed on human subjects. The achieved registration accuracy (2-4 mm) is sufficient to guide the choice of puncture site and trajectory of an epidural needle.
New graduate registered nurses' knowledge of patient safety and practice: A literature review.
Murray, Melanie; Sundin, Deborah; Cope, Vicki
2018-01-01
To critically appraise available literature and summarise evidence pertaining to the patient safety knowledge and practices of new graduate registered nurses. Responsibility for patient safety should not be limited to the practice of the bedside nurses, rather the responsibility of all in the healthcare system. Previous research identified lapses in safety across the health care, more specifically with new practitioners. Understanding these gaps and what may be employed to counteract them is vital to ensuring patient safety. A focused review of research literature. The review used key terms and Boolean operators across a 5-year time frame in CINAHL, Medline, psycINFO and Google Scholar for research articles pertaining to the area of enquiry. Eighty-four articles met the inclusion criteria, 39 discarded due to irrelevant material and 45 articles were included in the literature review. This review acknowledges that nursing has different stages of knowledge and practice capabilities. A theory-practice gap for new graduate registered nurses exists, and transition to practice is a key learning period setting new nurses on the path to becoming expert practitioners. Within the literature, there was little to no acknowledgement of patient safety knowledge of the newly registered nurse. Issues raised in the 1970s remain a concern for today's new graduate registered nurses. Research has recognised several factors affecting transition from nursing student to new graduate registered nurse. These factors are leaving new practitioners open to potential errors and risking patient safety. Understanding the knowledge of a new graduate registered nurse upon entering clinical practice may assist in organisations providing appropriate clinical and theoretical support to these nurses during their transition. © 2017 John Wiley & Sons Ltd.
Transitioning into new clinical areas of practice: An integrative review of the literature.
Kinghorn, Grant R; Halcomb, Elizabeth J; Froggatt, Terry; Thomas, Stuart Dm
2017-12-01
To critically synthesise research related to the transition of registered nurses into new areas of clinical practice. Global workforce shortages and rising healthcare demands have encouraged registered nurses to move into new clinical settings. While a body of literature reports on the transition of newly qualified nurses, evidence surrounding the transition of more experienced registered nurses to new clinical areas remains poorly explored. An integrative review was conducted, guided by Whittemore and Knafl (Journal of Advanced Nursing, 52, 2005, 546) framework. An electronic database search was conducted for papers published between 1996-2016. Papers were then subjected to a methodological quality appraisal, with findings synthesised using thematic analysis into core themes. Ten articles met the inclusion criteria. Three themes emerged, namely Support, Professional Development and Emotional Impact. These themes suggest that transitioning nurses experience challenges in adapting to new clinical areas and developing necessary skills. Such challenges prompted various emotional and physical responses. While formal and informal support systems were regarded as valuable by transitioning nurses, they were inconsistent across the new clinical areas. There is some evidence to highlight the initial shock and emotional stress experienced by registered nurses during transition to a new clinical area. However, the influence of formal and informal support systems for such registered nurses is far from conclusive. Further research is needed, to examine registered nurse transition into a variety of clinical areas to inform workforce support, policy and practices. The demand of health care is growing while global shortages of nursing workforce remain. To ensure retention and enhance the transition experience of registered nurses, it is important for nurse leaders, managers and policymakers to understand the transition experience and factors that impact this experience. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Khandelwal, A.; Karpatne, A.; Kumar, V.
2017-12-01
In this paper, we present novel methods for producing surface water maps at 30 meter spatial resolution at a daily temporal resolution. These new methods will make use of the MODIS spectral data from Terra (available daily since 2000) to produce daily maps at 250 meter and 500 meter resolution, and then refine them using the relative elevation ordering of pixels at 30 meter resolution. The key component of these methods is the use of elevation structure (relative elevation ordering) of a water body. Elevation structure is not explicitly available at desired resolution for most water bodies in the world and hence it will be estimated using our previous work that uses the history of imperfect labels. In this paper, we will present a new technique that uses elevation structure (unlike existing pixel based methods) to enforce temporal consistency in surface water extents (lake area on nearby dates is likely to be very similar). This will greatly improve the quality of the MODIS scale land/water labels since daily MODIS data can have a large amount of missing (or poor quality) data due to clouds and other factors. The quality of these maps will be further improved using elevation based resolution refinement approach that will make use of elevation structure estimated at Landsat scale. With the assumption that elevation structure does not change over time, it provides a very effective way to transfer information between datasets even when they are not observed concurrently. In this work, we will derive elevation structure at Landsat scale from monthly water extent maps spanning 1984-2015, publicly available through a joint effort of Google Earth Engine and the European Commission's Joint Research Centre (JRC). This elevation structure will then be used to refine spatial resolution of Modis scale maps from 2000 onwards. We will present the analysis of these methods on a large and diverse set of water bodies across the world.
Research on Integrated Geophysics Detect Potential Ground Fissure in City
NASA Astrophysics Data System (ADS)
Qian, R.
2017-12-01
North China confined aquifer lied 70 to 200 meters below the earth's surface has been exploited for several decades, which resulted in confined water table declining and has generated a mass of ground fissure. Some of them has reached the surface and the other is developing. As it is very difficult to stop the ground fissure coming into being, measures of avoiding are often taken. It brings great potential risk to urban architecture and municipal engineering. It is very important to find out specific distribution and characteristic of potential ground fissure in city with high resolution. The ground fissure is concealed, therefor, geophysical method is an important technology to detecting concealed ground fissure. However, it is very difficult to detect the characteristics of the superficial part of ground fissure directly, as it lies dozens of meters below and has only scores of centimeters fault displacement. This paper studies applied ground penetration radar, surface wave and shallow refleciton seismic to detect ground fissure. It sets up model of surface by taking advantage of high resolution of ground penetrating radar data, constrains Reilay wave inversion and improves its resolution. The high resolution reflection seismic is good at detecting the geology structure. The data processing and interpretation technique is developmented to avoid the pitfall and improve the aliability of the rusult. The experiment has been conducted in Shunyi District, Beijing in 2016. 5 lines were settled to collect data of integrated geophysical method. Development zone of concealed ground fissure was found and its ultra shallow layer location was detected by ground penetrating radar. A trial trench of 6 meters in depth was dug and obvious ground fissure development was found. Its upper end was 1.5 meters beneath the earth's surface with displacement of 0.3 meters. The favorable effect of this detection has provided a new way for detecting ground fissure in cities of China, such as Beijing and Xi'an etc. Keyword: Ground Fissure, GPR, Surface Wave; Shallow Reflection Seismic
High-resolution seismic reflection survey at Dover AFB: A comparison of three seismic sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cardimona, S.; Kadinsky-Cade, K.; Miller, R.
1996-11-01
In June of 1995, the Earth Sciences Division of the Air Force Phillips Lab, with survey equipment from the University of Delaware and assisted by the Kansas Geological Survey and Elohi Geophysics, conducted a geophysical site characterization of the SERDP-funded Groundwater Remediation Field Lab (GRFL) located at Dover AFB, Delaware and administered by Applied Research Associates for USAF Armstrong Lab. Seismic data were collected in order to (1) compare the results using three different compressional sources and (2) cover the field site well enough to characterize the seismic response of the shallow subsurface. This paper will focus primarily on themore » first of these two goals. Seismic data were collected along three north-south profiles set 10 meters apart, each profile with a different compressional source: a 5.5kg sledgehammer, a 12-gauge firing rod from Betsy Seisgun Inc. shooting 150 grain blanks, and a portable piezoelectrically driven vibrator, developed by Elohi Geophysics, operating with a 90Hz-450Hz sweep. An east-west cross line was collected using the sledgehammer source in order to tie the three profiles together. A laser theodolite provided station location and elevation control. The primary targets were the water table (that had been marked on maps at a depth of about 3 meters) and a sand-clay interface at about 15 meters depth. We collected 24-channel CMP data using a half meter spacing of both source and 100Hz geophones. Field C after initial walkaway noise testing with each source did not show any one source to be outstanding A practical early result of the seismic survey showed the water table to be at just over 10 meters. We have associated the strongest reflection event with the water-table interface. Seismic data comparison in this study is based on spectral content, total energy and signal-to-noise ratios, as well as a discussion of coherency of the primary reflection event at the water table.« less
NASA Technical Reports Server (NTRS)
Quattrochi, Dale A.; Emerson, Charles W.; Lam, Nina Siu-Ngan; Laymon, Charles A.
1997-01-01
The Image Characterization And Modeling System (ICAMS) is a public domain software package that is designed to provide scientists with innovative spatial analytical tools to visualize, measure, and characterize landscape patterns so that environmental conditions or processes can be assessed and monitored more effectively. In this study ICAMS has been used to evaluate how changes in fractal dimension, as a landscape characterization index, and resolution, are related to differences in Landsat images collected at different dates for the same area. Landsat Thematic Mapper (TM) data obtained in May and August 1993 over a portion of the Great Basin Desert in eastern Nevada were used for analysis. These data represent contrasting periods of peak "green-up" and "dry-down" for the study area. The TM data sets were converted into Normalized Difference Vegetation Index (NDVI) images to expedite analysis of differences in fractal dimension between the two dates. These NDVI images were also resampled to resolutions of 60, 120, 240, 480, and 960 meters from the original 30 meter pixel size, to permit an assessment of how fractal dimension varies with spatial resolution. Tests of fractal dimension for two dates at various pixel resolutions show that the D values in the August image become increasingly more complex as pixel size increases to 480 meters. The D values in the May image show an even more complex relationship to pixel size than that expressed in the August image. Fractal dimension for a difference image computed for the May and August dates increase with pixel size up to a resolution of 120 meters, and then decline with increasing pixel size. This means that the greatest complexity in the difference images occur around a resolution of 120 meters, which is analogous to the operational domain of changes in vegetation and snow cover that constitute differences between the two dates.
Airborne Laser Swath Mapping: Improved Penetration of Dense Vegetation Opens New Applications
NASA Astrophysics Data System (ADS)
Carter, W. E.; Shrestha, R. L.; Slatton, K. C.
2009-12-01
Historically, mapping structures and terrain obscured by dense forests has been problematical, because shadows limit or prevent the use of airborne photogrammetric techniques, and ground surveying techniques are slow, labor intensive, and too costly for many applications. Airborne laser swath mapping (ALSM) units with pulse rates of a few thousand to a few tens of thousands of pulses per second typically resulted in 1 or 2 points per square meter of terrain, which worked reasonably well in sparse to moderately forested areas. For example, data collected with a 30 kHz laser, provided sufficient returns from the ground in areas covered with redwood, mixed hardwoods, and conifer forests, to create 1 to 2 meter resolution bare earth digital elevation models (DEM). These DEMs were useful in studies of forest covered landslides, terraces, and fault lines. However, in dense semi-tropical areas of Florida, with primary and secondary canopies that include dense brush such as palmetto, the DEMs were significantly degraded, and in many areas it was not possible to derive bare earth DEMs that were reliable in height to better than 0.5 to 1.0 meter. In 2007 the UF purchased a second generation Optech ALSM unit that has decimeter accuracy ranging with pulse rates of 100 to 125 kHz. Flying at 600 meters AGL, 60 meters per second, and using a scan angle of ± 20 degrees and scan rate of 40 Hz, results in about 5 laser pulses per square meter within a single swath. In April 2009 a UF team collected ALSM observations covering approximately 2000 acres at Caracol, Belize, to support archaeological studies of the ancient (650 to 900AD) Mayan city, which is largely covered with dense jungle. By overlapping adjacent swaths by 50%, and flying the project area twice with orthogonal flight lines, an accumulated data set containing approximately 20 pulses per square meter, with a distribution of incident angles was realized. The Caracol area has been under study for 25 years and traditional mapping techniques involved cutting pathways through the jungle, typically at 50 meter intervals, and using transits, electronic distance measuring instruments and total stations to map visible features. Without completely clearing the vegetation, it was difficult for ground surveyors to identify and map all of the pertinent features, and preliminary analysis suggest that the ALSM data display areas of previously unmapped mounded settlement, as well as subtle features in the terrain, including shallow agricultural terraces. The ability to map structures and terrain in areas covered with semi-tropical and tropical forests and jungles opens new opportunities for archaeological studies, and promises to impact geological and geophysical studies in these difficult to map regions as well.
Method to produce American Thoracic Society flow-time waveforms using a mechanical pump.
Hankinson, J L; Reynolds, J S; Das, M K; Viola, J O
1997-03-01
The American Thoracic Society (ATS) recently adopted a new set of 26 standard flow-time waveforms for use in testing both diagnostic and monitoring devices. Some of these waveforms have a higher frequency content than present in the ATS-24 standard volume-time waveforms, which, when produced by a mechanical pump, may result in a pump flow output that is less than the desired flow due to gas compression losses within the pump. To investigate the effects of gas compression, a mechanical pump was used to generate the necessary flows to test mini-Wright and Assess peak expiratory flow (PEF) meters. Flow output from the pump was measured by two different independent methods, a pneumotachometer and a method based on piston displacement and pressure measured within the pump. Measuring output flow based on piston displacement and pressure has been validated using a pneumotachometer and mini-Wright PEF meter, and found to accurately measure pump output. This method introduces less resistance (lower back-pressure) and dead space volume than using a pneumotachometer in series with the meter under test. Pump output flow was found to be lower than the desired flow both with the mini-Wright and Assess meters (for waveform No. 26, PEFs 7.1 and 10.9% lower, respectively). To compensate for losses due to gas compression, we have developed a method of deriving new input waveforms, which, when used to drive a commercially available mechanical pump, accurately and reliably produces the 26 ATS flow-time waveforms, even those with the fastest rise-times.
NASA Astrophysics Data System (ADS)
Holden, Z.; Cushman, S.; Evans, J.; Littell, J. S.
2009-12-01
The resolution of current climate interpolation models limits our ability to adequately account for temperature variability in complex mountainous terrain. We empirically derive 30 meter resolution models of June-October day and nighttime temperature and April nighttime Vapor Pressure Deficit (VPD) using hourly data from 53 Hobo dataloggers stratified by topographic setting in mixed conifer forests near Bonners Ferry, ID. 66%, of the variability in average June-October daytime temperature is explained by 3 variables (elevation, relative slope position and topographic roughness) derived from 30 meter digital elevation models. 69% of the variability in nighttime temperatures among stations is explained by elevation, relative slope position and topographic dissection (450 meter window). 54% of variability in April nighttime VPD is explained by elevation, soil wetness and the NDVIc derived from Landsat. We extract temperature and VPD predictions at 411 intensified Forest Inventory and Analysis plots (FIA). We use these variables with soil wetness and solar radiation indices derived from a 30 meter DEM to predict the presence and absence of 10 common forest tree species and 25 shrub species. Classification accuracies range from 87% for Pinus ponderosa , to > 97% for most other tree species. Shrub model accuracies are also high with greater than 90% accuracy for the majority of species. Species distribution models based on the physical variables that drive species occurrence, rather than their topographic surrogates, will eventually allow us to predict potential future distributions of these species with warming climate at fine spatial scales.
Use of the Cygnus GlucoWatch biographer at a diabetes camp.
Gandrud, Laura M; Paguntalan, Helen U; Van Wyhe, M Michelle; Kunselman, Betsy L; Leptien, Amy D; Wilson, Darrell M; Eastman, Richard C; Buckingham, Bruce A
2004-01-01
Detection and prevention of nocturnal hypoglycemia is a major medical concern at diabetes camps. We conducted an open-label trial of the Cygnus GlucoWatch biographer to detect nocturnal hypoglycemia in a diabetes camp, a nonclinical environment with multiple activities. Forty-five campers (7-17 years old) wore a biographer. The biographer was placed on the arm at 6:00 PM, with the low alarm set to 85 mg/dL (4.7 mmol/L). Overnight glucose monitoring occurred per usual camp protocol. Counselors were to check and record blood glucose values if the biographer alarmed. Biographers were worn for 154 nights by 45 campers. After a 3-hour warm-up period, 67% of biographers were calibrated, of which 28% were worn the entire night (12 hours). Thirty-four percent of readings were skipped because of: "data errors" (65%), sweat (20%), and temperature change (16%). Reported biographer values correlated with meter glucose values measured 11 to 20 minutes later (r = 0.90). Of 20 low-glucose alarms with corresponding meter values measured within 20 minutes, there were 10 true-positive alarms, 10 false-positive alarms, and no false-negative alarms. Campers reported sleep disruption 32% of the nights, and 74% found the biographer helpful. Campers reported they would wear the biographer 4 to 5 nights each week. Half of the biographer low-glucose alarms that had corresponding blood meter values were true-positive alarms, and the remaining were false-positive alarms. There was close correlation between the biographer and meter glucose values. The majority of campers found the biographer helpful and would use it at home.
NASA Technical Reports Server (NTRS)
Yanow, Gilbert
1996-01-01
Pyranometer generates output potential of about 300 mV in maximum sunlight. Designed to monitor insolation at accuracy within 5 percent of accuracy of instruments ordinarily used for this purpose. Suitable for use in school laboratories and perhaps in commercial facilities where expense of more precise instrument not justified. Slightly more complex pyranometer intended primarily for use in agricultural setting described in "Inexpensive Meter For Total Solar Radiation" (NPO-16741).
Speed of Sound in Metal Pipes: An Inexpensive Lab
ERIC Educational Resources Information Center
Huggins, Elisha
2008-01-01
Our favorite demonstration for sound waves is to set up a compressional pulse on a horizontally stretched Slinky[TM]. One can easily watch the pulse move back and forth at a speed of the order of one meter per second. Watching this demonstration, it occurred to us that the same thing might happen in a steel pipe if you hit the end of the pipe with…
A dynamic water-quality modeling framework for the Neuse River estuary, North Carolina
Bales, Jerad D.; Robbins, Jeanne C.
1999-01-01
As a result of fish kills in the Neuse River estuary in 1995, nutrient reduction strategies were developed for point and nonpoint sources in the basin. However, because of the interannual variability in the natural system and the resulting complex hydrologic-nutrient inter- actions, it is difficult to detect through a short-term observational program the effects of management activities on Neuse River estuary water quality and aquatic health. A properly constructed water-quality model can be used to evaluate some of the potential effects of manage- ment actions on estuarine water quality. Such a model can be used to predict estuarine response to present and proposed nutrient strategies under the same set of meteorological and hydrologic conditions, thus removing the vagaries of weather and streamflow from the analysis. A two-dimensional, laterally averaged hydrodynamic and water-quality modeling framework was developed for the Neuse River estuary by using previously collected data. Development of the modeling framework consisted of (1) computational grid development, (2) assembly of data for model boundary conditions and model testing, (3) selection of initial values of model parameters, and (4) limited model testing. The model domain extends from Streets Ferry to Oriental, N.C., includes seven lateral embayments that have continual exchange with the main- stem of the estuary, three point-source discharges, and three tributary streams. Thirty-five computational segments represent the mainstem of the estuary, and the entire framework contains a total of 60 computa- tional segments. Each computational cell is 0.5 meter thick; segment lengths range from 500 meters to 7,125 meters. Data that were used to develop the modeling framework were collected during March through October 1991 and represent the most comprehensive data set available prior to 1997. Most of the data were collected by the North Carolina Division of Water Quality, the University of North Carolina Institute of Marine Sciences, and the U.S. Geological Survey. Limitations in the modeling framework were clearly identified. These limitations formed the basis for a set of suggestions to refine the Neuse River estuary water-quality model.
Hoben, Matthias; Knopp-Sihota, Jennifer A.; Nesari, Maryam; Chamberlain, Stephanie A.; Squires, Janet E.; Norton, Peter G.; Cummings, Greta G.; Stevens, Bonnie J.; Estabrooks, Carole A.
2017-01-01
Background: Poor health of health care workers affects quality of care, but research and health data for health care workers are scarce. Our aim was to compare physical/mental health among health care worker groups 1) within nursing homes and pediatric hospitals, 2) between the 2 settings and 3) with the physical/mental health of the Canadian population. Methods: Using cross-sectional data collected as part of the Translating Research in Elder Care program and the Translating Research on Pain in Children program, we examined the health of health care workers. In nursing homes, 169 registered nurses, 139 licensed practical nurses, 1506 care aides, 145 allied health care providers and 69 managers were surveyed. In pediatric hospitals, 63 physicians, 747 registered nurses, 155 allied health care providers, 49 nurse educators and 22 managers were surveyed. After standardization of the data for age and sex, we applied analyses of variance and general linear models, adjusted for multiple testing. Results: Nursing home workers and registered nurses in pediatric hospitals had poorer mental health than the Canadian population. Scores were lowest for registered nurses in nursing homes (mean difference -4.4 [95% confidence interval -6.6 to -2.6]). Physicians in pediatric hospitals and allied health care providers in nursing homes had better physical health than the general population. We also found important differences in physical/mental health for care provider groups within and between care settings. Interpretation: Mental health is especially poor among nursing home workers, who care for a highly vulnerable and medically complex population of older adults. Strategies including optimized work environments are needed to improve the physical and mental health of health care workers to ameliorate quality of patient care. PMID:29162609
Feldman, Harriet Ruth; DeVito, Nicholas J; Mendel, Jonathan; Carroll, David E; Goldacre, Ben
2018-03-05
We set out to document how NHS trusts in the UK record and share disclosures of conflict of interest by their employees. Cross-sectional study of responses to a Freedom of Information Act request for Gifts and Hospitality Registers. NHS Trusts (secondary/tertiary care organisations) in England. 236 Trusts were contacted, of which 217 responded. We assessed all disclosures for completeness and openness, scoring them for achieving each of five measures of transparency. 185 Trusts (78%) provided a register. 71 Trusts did not respond within the 28 day time limit required by the FoIA. Most COI registers were incomplete by design, and did not contain the information necessary to assess conflicts of interest. 126/185 (68%) did not record the names of recipients. 47/185 (25%) did not record the cash value of the gift or hospitality. Only 31/185 registers (16%) contained the names of recipients, the names of donors, and the cash amounts received. 18/185 (10%) contained none of: recipient name, donor name, and cash amount. Only 15 Trusts had their disclosure register publicly available online (6%). We generated a transparency index assessing whether each Trust met the following criteria: responded on time; provided a register; had a register with fields identifying donor, recipient, and cash amount; provided a register in a format that allowed further analysis; and had their register publicly available online. Mean attainment was 1.9/5; no NHS trust met all five criteria. Overall, recording of employees' conflicts of interest by NHS trusts is poor. None of the NHS Trusts in England met all transparency criteria. 19 did not respond to our FoIA requests, 51 did not provide a Gifts and Hospitality Register and only 31 of the registers provided contained enough information to assess employees' conflicts of interest. Despite obligations on healthcare professionals to disclose conflicts of interest, and on organisations to record these, the current system for logging and tracking such disclosures is not functioning adequately. We propose a simple national template for reporting conflicts of interest, modelled on the US 'Sunshine Act'. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Inherent limitations of nondestructive chlorophyll meters: a comparison of two types of meters
NASA Technical Reports Server (NTRS)
Monje, O. A.; Bugbee, B.
1992-01-01
Two types of nondestructive chlorophyll meters were compared with a standard, destructive chlorophyll measurement technique. The nondestructive chlorophyll meters were 1) a custom built, single-wavelength meter, and 2) the recently introduced, dual-wavelengh, chlorophyll meter from Minolta (model SPAD-502). Data from both meters were closely correlated with destructive measurements of chlorophyll (r2 = 0.90 and 0.93; respectively) for leaves with chlorophyll concentrations ranging from 100 to 600 mg m-2, but both meters consistently overestimated chlorophyll outside this range. Although the dual-wavelength meter was slightly more accurate than the single-wavelength meter (higher r2), the light-scattering properties of leaf cells and the nonhomogeneous distribution of chlorophyll in leaves appear to limit the ability of all meters to estimate in vivo chlorophyll concentration.
NASA Technical Reports Server (NTRS)
Paulson, J. W.; Whitten, P. D.; Stumpfl, S. C.
1982-01-01
A wind-tunnel investigation incorporating both static and wind-on testing was conducted in the Langley 4- by 7-Meter Tunnel to determine the effects of vectored thrust along with spanwise blowing on the low-speed aerodynamics of an advanced fighter configuration. Data were obtained over a large range of thrust coefficients corresponding to takeoff and landing thrust settings for many nozzle configurations. The complete set of static thrust data and the complete set of longitudinal aerodynamic data obtained in the investigation are presented. These data are intended for reference purposes and, therefore, are presented without analysis or comment. The analysis of the thrust-induced effects found in the investigation are not discussed.
2011-01-01
Background The 'Physical Activity Care Pathway' (a Pilot for the 'Let's Get Moving' policy) is a systematic approach to integrating physical activity promotion into the primary care setting. It combines several methods reported to support behavioural change, including brief interventions, motivational interviewing, goal setting, providing written resources, and follow-up support. This paper compares costs falling on the UK National Health Service (NHS) of implementing the care pathway using two different recruitment strategies and provides initial insights into the cost of changing physical activity behaviour. Methods A combination of a time driven variant of activity based costing, audit data through EMIS and a survey of practice managers provided patient-level cost data for 411 screened individuals. Self reported physical activity data of 70 people completing the care pathway at three month was compared with baseline using a regression based 'difference in differences' approach. Deterministic and probabilistic sensitivity analyses in combination with hypothesis testing were used to judge how robust findings are to key assumptions and to assess the uncertainty around estimates of the cost of changing physical activity behaviour. Results It cost £53 (SD 7.8) per patient completing the PACP in opportunistic centres and £191 (SD 39) at disease register sites. The completer rate was higher in disease register centres (27.3% vs. 16.2%) and the difference in differences in time spent on physical activity was 81.32 (SE 17.16) minutes/week in patients completing the PACP; so that the incremental cost of converting one sedentary adult to an 'active state' of 150 minutes of moderate intensity physical activity per week amounts to £ 886.50 in disease register practices, compared to opportunistic screening. Conclusions Disease register screening is more costly than opportunistic patient recruitment. However, additional costs come with a higher completion rate and better outcomes in terms of behavioural change in patients completing the care pathway. Further research is needed to rigorously evaluate intervention efficiency and to assess the link between behavioural change and changes in quality adjusted life years (QALYs). PMID:21605400
Olatunya, Oladele; Ogundare, Olatunde; Olaleye, Abiola; Agaja, Oyinkansola; Omoniyi, Evelyn; Adeyefa, Babajide; Oluwadiya, Kehinde; Oyelami, Oyeku
2016-05-01
Prompt and accurate diagnosis is needed to prevent the untoward effects of anaemia on children. Although haematology analyzers are the gold standard for accurate measurement of haemoglobin or haematocrit for anaemia diagnosis, they are often out of the reach of most health facilities in resource-poor settings thus creating a care gap. We conducted this study to examine the agreement between a point-of-care device and haematology analyzer in determining the haematocrit levels in children and to determine its usefulness in diagnosing anaemia in resource-poor settings. EDTA blood samples collected from participants were processed to estimate their haematocrits using the two devices (Mindray BC-3600 haematology analyzer and Portable Mission Hb/Haemotocrit testing system). A pairwise t-test was used to compare the haematocrit (PCV) results from the automated haematology analyzer and the portable haematocrit meter. The agreement between the two sets of measurements was assessed using the Bland and Altman method where the mean, standard deviation and limit of agreement of paired results were calculated. The intraclass and concordance correlation coefficients were 0.966 and 0.936. Sensitivity and specificity were 97.85% and 94.51% respectively while the positive predictive and negative predictive values were 94.79% and 97.73%. The Bland and Altman`s limit of agreement was -5.5-5.1 with the mean difference being -0.20 and a non-ignificant variability between the two measurements (p = 0.506). Haematocrit determined by the portable testing system is comparable to that determined by the haematology analyzer. We therefore recommend its use as a point-of-care device for determining haematocrit in resource-poor settings where haematology analyzers are not available.
New experimental sites for borehole geophysics, hydrodynamics and long-term monitoringITORING
NASA Astrophysics Data System (ADS)
Pezard, P.; Aliance/Saltrans Team
2003-04-01
In order to provide platforms for the development of new downhole geophysical and hydrodynamic sensors, 4 sites are being developped with a series of nearby 100 m deep boreholes located with a few meters to 100 meters, at the most. The objective is to set-up a cluster of extremely well characterized in-situ laboratories at scales where experiments cannot be conducted in traditionnal labs. At least one borehole is continuously cored at each of the sites, and the core is fully characterized in petrological, petrophysical and geochemical terms. An emphasis is placed on fundamental and environmental applications such as hydrogeology, waste storage or the study of seismogenic faults, whether for characterization purposes or the development of long-term monitoring sensors and methods. These sites are developped with the support of CNRS, the University of Montpellier and the ALIANCE program financed by the European Commission. The 4 sites span different lithologies with granite at Ploemeur (Brittany, France), Miocene carbonates from a reefal platform in south Mallorca (Baleares, Spain), Valanginian marly limestone at Lavalette, near Montpellier (Languedoc, France), and unconsolidated sands in a coastal setting also near Montpellier. In the context of ALIANCE, the goal is to improve the investigation, characterisation and monitoring of coastal aquifers for vulnerability assessment. For this, a set of geophysical approaches for the quantitative evaluation of brine intrusion will be developped. This includes the design of 5 new geophysical and hydrodynamical logging/testing sensors. Two end-member sites in terms of hydrogeological behavior will be set up for long-term experimentation, the testing of the new tools, and the validation of site-specific experimental and modelling protocols from µm- to 100 m-scale. Active in-situ testing from short and longer-term injections with variable salinity fluids will simulate overdrafting or saline water intrusion.
A two-fluid model for avalanche and debris flows.
Pitman, E Bruce; Le, Long
2005-07-15
Geophysical mass flows--debris flows, avalanches, landslides--can contain O(10(6)-10(10)) m(3) or more of material, often a mixture of soil and rocks with a significant quantity of interstitial fluid. These flows can be tens of meters in depth and hundreds of meters in length. The range of scales and the rheology of this mixture presents significant modelling and computational challenges. This paper describes a depth-averaged 'thin layer' model of geophysical mass flows containing a mixture of solid material and fluid. The model is derived from a 'two-phase' or 'two-fluid' system of equations commonly used in engineering research. Phenomenological modelling and depth averaging combine to yield a tractable set of equations, a hyperbolic system that describes the motion of the two constituent phases. If the fluid inertia is small, a reduced model system that is easier to solve may be derived.
Design Considerations for a New Terminal Area Arrival Scheduler
NASA Technical Reports Server (NTRS)
Thipphavong, Jane; Mulfinger, Daniel
2010-01-01
Design of a terminal area arrival scheduler depends on the interrelationship between throughput, delay and controller intervention. The main contribution of this paper is an analysis of the above interdependence for several stochastic behaviors of expected system performance distributions in the aircraft s time of arrival at the meter fix and runway. Results of this analysis serve to guide the scheduler design choices for key control variables. Two types of variables are analyzed, separation buffers and terminal delay margins. The choice for these decision variables was tested using sensitivity analysis. Analysis suggests that it is best to set the separation buffer at the meter fix to its minimum and adjust the runway buffer to attain the desired system performance. Delay margin was found to have the least effect. These results help characterize the variables most influential in the scheduling operations of terminal area arrivals.
NASA Astrophysics Data System (ADS)
Kauahikaua, J.
A controlled source, time domain electromagnetic (TDEM) sounding survey was conducted in the Calico Hills area of the Nevada Test Site (NTS). The geoelectric structure was determined as an aid in the evaluation of the site for possible future storage of spent nuclear fuel or high level nuclear waste. The data were initially interpreted with a simple scheme that produces an apparent resistivity versus depth curve from the vertical magnetic field data. These curves are qualitatively interpreted much like standard Schlumberger resistivity sounding curves. Final interpretation made use of a layered earth Marquardt inversion computer program. The results combined with those from a set of Schlumberger soundings in the area show that there is a moderately resistive basement at a depth no greater than 800 meters. The basement resistivity is greater than 100 ohm meters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurt Derr; Milos Manic
Location Based Services (LBS), context aware applications, and people and object tracking depend on the ability to locate mobile devices, also known as localization, in the wireless landscape. Localization enables a diverse set of applications that include, but are not limited to, vehicle guidance in an industrial environment, security monitoring, self-guided tours, personalized communications services, resource tracking, mobile commerce services, guiding emergency workers during fire emergencies, habitat monitoring, environmental surveillance, and receiving alerts. This paper presents a new neural network approach (LENSR) based on a competitive topological Counter Propagation Network (CPN) with k-nearest neighborhood vector mapping, for indoor location estimationmore » based on received signal strength. The advantage of this approach is both speed and accuracy. The tested accuracy of the algorithm was 90.6% within 1 meter and 96.4% within 1.5 meters. Several approaches for location estimation using WLAN technology were reviewed for comparison of results.« less
Conception of a test bench to generate known and controlled conditions of refrigerant mass flow.
Martins, Erick F; Flesch, Carlos A; Flesch, Rodolfo C C; Borges, Maikon R
2011-07-01
Refrigerant compressor performance tests play an important role in the evaluation of the energy characteristics of the compressor, enabling an increase in the quality, reliability, and efficiency of these products. Due to the nonexistence of a refrigerating capacity standard, it is common to use previously conditioned compressors for the intercomparison and evaluation of the temporal drift of compressor performance test panels. However, there are some limitations regarding the use of these specific compressors as standards. This study proposes the development of a refrigerating capacity standard which consists of a mass flow meter and a variable-capacity compressor, whose speed is set based on the mass flow rate measured by the meter. From the results obtained in the tests carried out on a bench specifically developed for this purpose, it was possible to validate the concept of a capacity standard. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Madsen, Soren N.; Carsey, Frank D.; Turtle, Elizabeth P.
2003-01-01
The topographic data set obtained by MOLA has provided an unprecedented level of information about Mars' geologic features. The proposed flight of JIMO provides an opportunity to accomplish a similar mapping of and comparable scientific discovery for the Jovian moons through us of an interferometric imaging radar analogous to the Shuttle radar that recently generated a new topographic map of Earth. A Ka-band single pass across-track synthetic aperture radar (SAR) interferometer can provide very high resolution surface elevation maps. The concept would use two antennas mounted at the ends of a deployable boom (similar to the Shuttle Radar Topographic Mapper) extended orthogonal to the direction of flight. Assuming an orbit altitude of approximately 100 km and a ground velocity of approximately 1.5 km/sec, horizontal resolutions at the 10 meter level and vertical resolutions at the sub-meter level are possible.
NASA Technical Reports Server (NTRS)
Madsen, S. N.; Carsey, F. D.; Turtle, E. P.
2003-01-01
The topographic data set obtained by MOLA has provided an unprecedented level of information about Mars' geologic features. The proposed flight of JIMO provides an opportunity to accomplish a similar mapping of and comparable scientific discovery for the Jovian moons through use of an interferometric imaging radar analogous to the Shuttle radar that recently generated a new topographic map of Earth. A Ka-band single pass across-track synthetic aperture radar (SAR) interferometer can provide very high resolution surface elevation maps. The concept would use two antennas mounted at the ends of a deployable boom (similar to the Shuttle Radar Topographic Mapper) extended orthogonal to the direction of flight. Assuming an orbit altitude of approximately 100km and a ground velocity of approximately 1.5 km/sec, horizontal resolutions at the 10 meter level and vertical resolutions at the sub-meter level are possible.
NASA Astrophysics Data System (ADS)
Bottom, Michael; Muirhead, Philip S.; Swift, Jonathan J.; Zhao, Ming; Gardner, Paul; Plavchan, Peter P.; Riddle, Reed L.; Herzig, Erich; Johnson, John A.; Wright, Jason T.; McCrady, Nate; Wittenmyer, Robert A.
2014-08-01
We present the science motivation, design, and on-sky test data of a high-throughput fiber coupling unit suitable for automated 1-meter class telescopes. The optical and mechanical design of the fiber coupling is detailed and we describe a flexible controller software designed specifically for this unit. The system performance is characterized with a set of numerical simulations, and we present on-sky results that validate the performance of the controller and the expected throughput of the fiber coupling. This unit was designed specifically for the MINERVA array, a robotic observatory consisting of multiple 0.7 m telescopes linked to a single high-resolution stabilized spectrograph for the purpose of exoplanet discovery using high-cadence radial velocimetry. However, this unit could easily be used for general astronomical purposes requiring fiber coupling or precise guiding.
Capabilities and Present Status of The Sicaya Radio Telescope in Peru
NASA Astrophysics Data System (ADS)
Ishitsuka, J. K.; Kobayashi, H.; Miyoshi, M.
2017-07-01
The private telephone company, Telefónica del Perú, stopped operations of the Sicaya Intelsat Station in 2000, we knew that they were looking for some institution to own the Station in 2002 and begun conversations. Finally in 2008, the whole communications station with a 32-meters parabolic antenna was donated to the Geophysical Institute of Peru. Many things have happened since that, but finally we are almost ready to have a radio telescope. National Astronomical Observatory of Japan contributed enormously to set up the radio telescope. Initially as a single dish radio telescope, it will observe methanol maser at 6.7 GHz of young stellar objects. In the near future, equipping for VLBI observations is in the scope. Sicaya is situated on the central part of Peru at 3,370 meters of altitude and the weather is benign for radio astronomical observations, also humidity is low and allows have radio telescopes free of rust.
Metering Best Practices, A Guide to Achieving Utility Resource Efficiency, Release 2.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, Greg; Hunt, W. D.; Pugh, Ray
2011-08-31
This release is an update and expansion of the information provided in Release 1.0 of the Metering Best Practice Guide that was issued in October 2007. This release, as was the previous release, was developed under the direction of the U.S. Department of Energy's Federal Energy Management Program (FEMP). The mission of FEMP is to facilitate the Federal Government's implementation of sound cost-effective energy management and investment practices to enhance the nation's energy security and environmental stewardship. Each of these activities is directly related to achieving requirements set forth in the Energy Policy Acts of 1992 and 2005, the Energymore » Independence and Security Act (EISA) of 2007, and the goals that have been established in Executive Orders 13423 and 13514 - and also those practices that are inherent in sound management of Federal financial and personnel resources.« less
ERIC Educational Resources Information Center
Benz, Stephen
2006-01-01
Schools and universities recognize that many of the people and neighborhoods they serve expect education institutions to embrace environmental stewardship and sustainable design. Standards such as the LEED-registered facility program, managed by the U.S. Green Building Council, are receiving more attention. Schools can demonstrate their commitment…
21 CFR 589.1 - Substances prohibited from use in animal food or feed.
Code of Federal Regulations, 2010 CFR
2010-04-01
... establish, amend, or repeal a regulation under this part on the basis of new scientific evaluation or... the form set forth in § 571.1 of this chapter, and will be published in the Federal Register for...
Women in Combat Arms: A Study of the Global War on Terror
2013-05-23
Discus Throw Javelin Throw 11.9 sec 1.68 meters 5.695 meters 13.75 meters 41.92 meters 45.57 meters 10.3 sec 1.98 meters 7.825 meters 17.12 meters...in the development of this product. Among them, I must include all those who subjected themselves to interviews: BG Hutmacher, COL Evans, and COL...15 Table 2. KIA and WIA for OIF and OEF 2001- Present Table 3. Primary Diagnosis Groups by Gender for All Soldiers
Evaluation of Skybox Video and Still Image products
NASA Astrophysics Data System (ADS)
d'Angelo, P.; Kuschk, G.; Reinartz, P.
2014-11-01
The SkySat-1 satellite lauched by Skybox Imaging on November 21 in 2013 opens a new chapter in civilian earth observation as it is the first civilian satellite to image a target in high definition panchromatic video for up to 90 seconds. The small satellite with a mass of 100 kg carries a telescope with 3 frame sensors. Two products are available: Panchromatic video with a resolution of around 1 meter and a frame size of 2560 × 1080 pixels at 30 frames per second. Additionally, the satellite can collect still imagery with a swath of 8 km in the panchromatic band, and multispectral images with 4 bands. Using super-resolution techniques, sub-meter accuracy is reached for the still imagery. The paper provides an overview of the satellite design and imaging products. The still imagery product consists of 3 stripes of frame images with a footprint of approximately 2.6 × 1.1 km. Using bundle block adjustment, the frames are registered, and their accuracy is evaluated. Image quality of the panchromatic, multispectral and pansharpened products are evaluated. The video product used in this evaluation consists of a 60 second gazing acquisition of Las Vegas. A DSM is generated by dense stereo matching. Multiple techniques such as pairwise matching or multi image matching are used and compared. As no ground truth height reference model is availble to the authors, comparisons on flat surface and compare differently matched DSMs are performed. Additionally, visual inspection of DSM and DSM profiles show a detailed reconstruction of small features and large skyscrapers.
Jia, Yu; Ehlert, Ludwig; Wahlskog, Cecilia; Lundberg, Angela; Maurice, Christian
2017-12-05
Monitoring pollutants in stormwater discharge in cold climates is challenging. An environmental survey was performed by sampling the stormwater from Luleå Airport, Northern Sweden, during the period 2010-2013, when urea was used as a main component of aircraft deicing/anti-icing fluids (ADAFs). The stormwater collected from the runway was led through an oil trap to an infiltration pond to store excess water during precipitation periods and enhance infiltration and water treatment. Due to insufficient capacity, an emergency spillway was established and equipped with a flow meter and an automatic sampler. This study proposes a program for effective monitoring of pollutant discharge with a minimum number of sampling occasions when use of automatic samplers is not possible. The results showed that 90% of nitrogen discharge occurs during late autumn before the water pipes freeze and during snow melting, regardless of the precipitation during the remaining months when the pollutant discharge was negligible. The concentrations of other constituents in the discharge were generally low compared to guideline values. The best data quality was obtained using flow controlled sampling. Intensive time-controlled sampling during late autumn (few weeks) and snow melting (2 weeks) would be sufficient for necessary information. The flow meters installed at the rectangular notch appeared to be difficult to calibrate and gave contradictory results. Overall, the spillway was dry, as water infiltrated into the pond, and stagnant water close to the edge might be registered as flow. Water level monitoring revealed that the infiltration capacity gradually decreased with time.
Executive Functions of Divers Are Selectively Impaired at 20-Meter Water Depth.
Steinberg, Fabian; Doppelmayr, Michael
2017-01-01
Moving and acting underwater within recreational or occupational activities require intact executive functions, since they subserve higher cognitive functions such as successful self-regulation, coping with novel situations, and decision making; all of which could be influenced by nitrogen narcosis due to elevated partial pressure under water. However, specific executive functions that could provide a differentiated view on humans' cognitive performance ability have not yet been systematically analyzed in full-water immersion, which is a research gap addressed within this approach to contribute to a better understanding of nitrogen narcosis. In this study, 20 young, healthy, and certified recreational divers participated and performed three different executive-function tests: the Stroop test (Inhibition), the Number/Letter test (Task switching), the 2-back test (Updating/Working memory), and a simple reaction time test (Psychomotor performance). These tests were performed once on land, at 5-meter (m) water depth, and at 20-meter (m) water depth of an indoor diving facility in standardized test conditions (26°C in all water depths). A water-proofed and fully operational tablet computer was used to present visual stimuli and to register reaction times. Performance of the simple reaction time test was not different between underwater and land testing, suggesting that reaction times were not biased by the utilization of the tablet in water immersion. Executive functions were not affected by the shallow water immersion of 5-m water depth. However, performance scores in 20-m water depth revealed a decreased performance in the incongruent test condition (i.e., an index of inhibitory control ability) of the Stroop test, while all other tests were unaffected. Even though only one out of the three tested cognitive domains was affected, the impairment of inhibitory control ability even in relatively shallow water of 20-m is a critical component that should be considered for diver's safety, since inhibition is required in self-control requiring situations where impulsive and automatic behavior must be inhibited. Our interpretation of these selective impairments is based on a discussion suggesting that different neural networks within the central nervous system, which process specific executive functions, are affected differently by nitrogen narcosis.
Production facility layout by comparing moment displacement using BLOCPLAN and ALDEP Algorithms
NASA Astrophysics Data System (ADS)
Tambunan, M.; Ginting, E.; Sari, R. M.
2018-02-01
Production floor layout settings include the organizing of machinery, materials, and all the equipments used in the production process in the available area. PT. XYZ is a company that manufactures rubber and rubber compounds for retreading tire threaded with hot and cold cooking system. In the production of PT. XYZ is divided into three interrelated parts, namely Masterbatch Department, Department Compound, and Procured Thread Line Department. PT. XYZ has a production process with material flow is irregular and the arrangement of machine is complicated and need to be redesigned. The purpose of this study is comparing movement displacement using BLOCPLAN and ALDEP algorithm in order to redesign existing layout. Redesigning the layout of the production floor is done by applying algorithms of BLOCPLAN and ALDEP. The algorithm used to find the best layout design by comparing the moment displacement and the flow pattern. Moment displacement on the floor layout of the company’s production currently amounts to 2,090,578.5 meters per year and material flow pattern is irregular. Based on the calculation, the moment displacement for the BLOCPLAN is 1,551,344.82 meter per year and ALDEP is 1,600,179 meter per year. Flow Material resulted is in the form of straight the line.
λ-augmented tree for robust data collection in Advanced Metering Infrastructure
Kamto, Joseph; Qian, Lijun; Li, Wei; ...
2016-01-01
In this study, tree multicast configuration of smart meters (SMs) can maintain the connectivity and meet the latency requirements for the Advanced Metering Infrastructure (AMI). However, such topology is extremely weak as any single failure suffices to break its connectivity. On the other hand, the impact of a SM node failure can be more or less significant: a noncut SM node will have a limited local impact compared to a cut SM node that will break the network connectivity. In this work, we design a highly connected tree with a set of backup links to minimize the weakness of treemore » topology of SMs. A topology repair scheme is proposed to address the impact of a SM node failure on the connectivity of the augmented tree network. It relies on a loop detection scheme to define the criticality of a SM node and specifically targets cut SM node by selecting backup parent SM to cover its children. Detailed algorithms to create such AMI tree and related theoretical and complexity analysis are provided with insightful simulation results: sufficient redundancy is provided to alleviate data loss at the cost of signaling overhead. It is however observed that biconnected tree provides the best compromise between the two entities.« less
Acoustic treatment of the NASA Langley 4- by 7-meter tunnel: A feasibility study
NASA Technical Reports Server (NTRS)
Yu, J. C.; Abrahamson, A. L.
1986-01-01
A feasibility study for upgrading the NASA Langley 4- by 7-Meter Tunnel so that it may be used for aeroacoustic research related to helicopters is described. The requirements for noise research leading to the design of the next generation of helicopters impose a set of acoustic test criteria that no existing wind tunnel in the United States can presently meet. Included in this feasibility study are the following considerations: (1) an evaluation of general wind-tunnel requirements and desired tunnel background noise levels for helicopter aeroacoustic research; (2) an assessment of the present acoustic environment for testing model rotors; (3) a diagnostic investigation of tunnel background noise sources and paths; (4) acoustic treatment options for tunnel background noise reduction and a trade-off study between these options; (5) an engineering feasibility assessment of the selected option; and (6) an integrated analysis of study components and recommendations of treatment for an approach to meet the tunnel background noise reduction goal. It is concluded that the Langley 4- by 7-Meter Tunnel is a fundamentally suitable facility for helicopter aeroacoustic research. It is also concluded that acoustic treatment of this facility for meeting the required tunnel background noise goal can be accomplished technically at reasonable risk and cost.
A Composite Depth Scale for Sediments from Crevice Lake, Montana
Rosenbaum, J.G.; Skipp, G.; Honke, J.; Chapman, C.
2010-01-01
As part of a study to derive records of past environmental change from lake sediments in the western United States, a set of cores was collected from Crevice Lake, Montana, in late February and early March 2001. Crevice Lake (latitude 45.000N, longitude 110.578W, elevation 1,713 meters) lies adjacent to the Yellowstone River at the north edge of Yellowstone National Park. The lake is more than 31 meters deep and has a surface area of 7.76 hectares. The combination of small surface area and significant depth promote anoxic bottom-water conditions that preserve annual laminations (varves) in the sediment. Three types of cores were collected through the ice. The uppermost sediments were obtained in freeze cores that preserved the sediment water interface. Two sites were cored with a 5-centimeter diameter corer. Five cores were taken with a 2-meter-long percussion piston corer. The percussion core uses a plastic core liner with an inside diameter of 9 centimeters. Coring was done at two sites. Because of the relatively large diameter of the percussion cores, samples from these cores were used for a variety of analyses including pollen, charcoal, diatoms, stable isotopes, organic and inorganic carbon, elemental analyses, and magnetic properties.
λ-augmented tree for robust data collection in Advanced Metering Infrastructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamto, Joseph; Qian, Lijun; Li, Wei
In this study, tree multicast configuration of smart meters (SMs) can maintain the connectivity and meet the latency requirements for the Advanced Metering Infrastructure (AMI). However, such topology is extremely weak as any single failure suffices to break its connectivity. On the other hand, the impact of a SM node failure can be more or less significant: a noncut SM node will have a limited local impact compared to a cut SM node that will break the network connectivity. In this work, we design a highly connected tree with a set of backup links to minimize the weakness of treemore » topology of SMs. A topology repair scheme is proposed to address the impact of a SM node failure on the connectivity of the augmented tree network. It relies on a loop detection scheme to define the criticality of a SM node and specifically targets cut SM node by selecting backup parent SM to cover its children. Detailed algorithms to create such AMI tree and related theoretical and complexity analysis are provided with insightful simulation results: sufficient redundancy is provided to alleviate data loss at the cost of signaling overhead. It is however observed that biconnected tree provides the best compromise between the two entities.« less
Fernandez, I Diana; Chin, Nancy P; Devine, Carol M; Dozier, Ann M; Martina, Camille A; McIntosh, Scott; Thevenet-Morrison, Kelly; Yang, Hongmei
2015-10-01
We assessed the effects of a worksite multiple-component intervention addressing diet and physical activity on employees' mean body mass index (BMI) and the percentage of employees who were overweight or obese. This group-randomized trial (n = 3799) was conducted at 10 worksites in the northeastern United States. Worksites were paired and allocated into intervention and control conditions. Within- and between-groups changes in mean BMIs and in the percentage of overweight or obese employees were examined in a volunteer sample. Within-group mean BMIs decreased by 0.54 kilograms per meter squared (P = .02) and 0.12 kilograms per meter squared (P = .73) at the intervention and control worksites, respectively, resulting in a difference in differences (DID) decrease of 0.42 kilograms per meter squared (P = .33). The within-group percentage of overweight or obese employees decreased by 3.7% (P = .07) at the intervention worksites and increased by 4.9% (P = .1) at the control worksites, resulting in a DID decline of 8.6% (P = .02). Our findings support a worksite population strategy that might eventually reduce the prevalence of overweight and obesity by minimizing environmental exposures to calorically dense foods and increasing exposures to opportunities for energy expenditure within worksite settings.
Calibration of Clinical Audio Recording and Analysis Systems for Sound Intensity Measurement.
Maryn, Youri; Zarowski, Andrzej
2015-11-01
Sound intensity is an important acoustic feature of voice/speech signals. Yet recordings are performed with different microphone, amplifier, and computer configurations, and it is therefore crucial to calibrate sound intensity measures of clinical audio recording and analysis systems on the basis of output of a sound-level meter. This study was designed to evaluate feasibility, validity, and accuracy of calibration methods, including audiometric speech noise signals and human voice signals under typical speech conditions. Calibration consisted of 3 comparisons between data from 29 measurement microphone-and-computer systems and data from the sound-level meter: signal-specific comparison with audiometric speech noise at 5 levels, signal-specific comparison with natural voice at 3 levels, and cross-signal comparison with natural voice at 3 levels. Intensity measures from recording systems were then linearly converted into calibrated data on the basis of these comparisons, and validity and accuracy of calibrated sound intensity were investigated. Very strong correlations and quasisimilarity were found between calibrated data and sound-level meter data across calibration methods and recording systems. Calibration of clinical sound intensity measures according to this method is feasible, valid, accurate, and representative for a heterogeneous set of microphones and data acquisition systems in real-life circumstances with distinct noise contexts.
NASA Technical Reports Server (NTRS)
Rajmon, D.; Spudis, P.
2004-01-01
Maria Tranquillitatis and Fecunditatis have been mapped based on Clementine image mosaics and derived iron and titanium maps. Impact craters served as stratigraphic probes enabling better delineation of compositionally different basaltic units, determining the distribution of subsurface basalts, and providing estimates of total basalt thickness and the thickness of the surface units. Collected data indicate that volcanism in these maria started with the eruption of low-Ti basalts and evolved toward medium- and high-Ti basalts. Some of the high-Ti basalts in Mare Tranquillitatis began erupting early and were contemporaneous with the low- and medium-Ti basalts; these units form the oldest units exposed on the mare surface. Mare Tranquillitatis is mostly covered with high- Ti basalts. In Mare Fecunditatis, the volume of erupting basalts clearly decreased as the Ti content increased, and the high-Ti basalts occur as a few patches on the mare surface. The basalt in both maria is on the order of several hundred meters thick and locally may be as thick as 1600 m. The new basalt thickness estimates generally fall within the range set by earlier studies, although locally differ. The medium- to high-Ti basalts exposed at the surfaces of both maria are meters to tens of meters thick.
Accuracy of the Velotron ergometer and SRM power meter.
Abbiss, C R; Quod, M J; Levin, G; Martin, D T; Laursen, P B
2009-02-01
The purpose of this study was to determine the accuracy of the Velotron cycle ergometer and the SRM power meter using a dynamic calibration rig over a range of exercise protocols commonly applied in laboratory settings. These trials included two sustained constant power trials (250 W and 414 W), two incremental power trials and three high-intensity interval power trials. To further compare the two systems, 15 subjects performed three dynamic 30 km performance time trials. The Velotron and SRM displayed accurate measurements of power during both constant power trials (<1% error). However, during high-intensity interval trials the Velotron and SRM were found to be less accurate (3.0%, CI=1.6-4.5% and -2.6%, CI=-3.2--2.0% error, respectively). During the dynamic 30 km time trials, power measured by the Velotron was 3.7+/-1.9% (CI=2.9-4.8%) greater than that measured by the SRM. In conclusion, the accuracy of the Velotron cycle ergometer and the SRM power meter appears to be dependent on the type of test being performed. Furthermore, as each power monitoring system measures power at various positions (i.e. bottom bracket vs. rear wheel), caution should be taken when comparing power across the two systems, particularly when power is variable.
Educational needs and employment status of Scottish dental hygienists.
Ross, M K; Ibbetson, R J; Rennie, J S
2005-01-22
To investigate the educational needs and employment status of registered dental hygienists in Scotland. Three hundred and eighty one registered dental hygienists with postal addresses in Scotland. Structured questionnaire. A 76% response rate was achieved following two mailings. Of the respondents, 43% were in full-time employment albeit in more than one setting, mostly in the 'central belt' of Scotland. It was reported that 41% were employed in general dental practice with both NHS and private lists and 39% worked in a purely private setting. The introduction of extended clinical duties had been well received and 59% of subjects were interested in additional training in dental therapy, should this become available. Absence of funding for CPD was raised repeatedly, with only 41% reporting a degree of financial assistance. Greater accessibility to continuing education via distance learning, particularly in remote and rural settings, was requested by 73% of hygienists. This study identifies a number of issues in relation to this increasingly important group of healthcare professionals, which will inform the providers of oral healthcare. Although hygienists' involvement in CPD was commendable, results indicated that despite commitment to their profession, respondents did not always feel respected in terms of their employment status or support for continuing professional development.
Speaking up, being heard: registered nurses' perceptions of workplace communication.
Garon, Maryanne
2012-04-01
The aim of the present study was to explore nurses' perceptions of their own ability to speak up and be heard in the workplace. Nurses are central to patient care and patient safety in hospitals. Their ability to speak up and be heard greatly impacts their own work satisfaction, team work as well as patient safety. The present study utilized a qualitative approach, consisting of focus group interviews of 33 registered nurses (RNs), in staff or management positions from a variety of healthcare settings in California, USA. Data were analysed using thematic content analysis. Findings were organized into three categories: influences on speaking up, transmission and reception of a message and outcomes or results. The present study supported the importance of the manager in setting the culture of open communication. It is anticipated that findings from the present study may increase understandings of nurse views of communication within healthcare settings. The study highlights the importance of nurse managers in creating the communication culture that will allow nurses to speak up and be heard. These open communication cultures lead to better patient care, increased safety and better staff satisfaction. © 2011 Blackwell Publishing Ltd.
McCabe, Marita P; Mellor, David; Davison, Tanya E; Karantzas, Gery; von Treuer, Kathryn; O'Connor, Daniel W
2013-09-19
The high occurrence and under-treatment of clinical depression and behavioral and psychological symptoms of dementia (BPSD) within aged care settings is concerning, yet training programs aimed at improving the detection and management of these problems have generally been ineffective. This article presents a study protocol to evaluate a training intervention for facility managers/registered nurses working in aged care facilities that focuses on organisational processes and culture as well as knowledge, skills and self-efficacy. A Randomised Control Trial (RCT) will be implemented across 18 aged care facilities (divided into three conditions). Participants will be senior registered nurses and personal care attendants employed in the aged care facility. The first condition will receive the training program (Staff as Change Agents - Enhancing and Sustaining Mental Health in Aged Care), the second condition will receive the training program and clinical support, and the third condition will receive no intervention. Pre-, post-, 6-month and 12-month follow-up measures of staff and residents will be used to demonstrate how upskilling clinical leaders using our transformational training approach, as well as the use of a structured screening, referral and monitoring protocol, can address the mental health needs of older people in residential care. The expected outcome of this study is the validation of an evidence-based training program to improve the management of depression and BPSD among older people in residential care settings by establishing routine practices related to mental health. This relatively brief but highly focussed training package will be readily rolled out to a larger number of residential care facilities at a relatively low cost. Australia and New Zealand Clinical Trials Register (ANZCTR): The Universal Trial Number (UTN) is U1111-1141-0109.
Building a population-based diabetes register: an Italian experience.
Ballotari, Paola; Chiatamone Ranieri, Sofia; Vicentini, Massimo; Caroli, Stefania; Gardini, Andrea; Rodolfi, Rossella; Crucco, Roberto; Greci, Marina; Manicardi, Valeria; Giorgi Rossi, Paolo
2014-01-01
To describe the methodology used to set up the Reggio Emilia (northern Italy) Diabetes Register. The prevalence estimates on December 31st, 2009 are also provided. The Diabetes Register covers all residents in the Reggio Emilia province. The register was created by deterministic linkage of six routinely collected data sources through a definite algorithm able to ascertain cases and to distinguish type of diabetes and model of care: Hospital Discharge, Drug Dispensation, Biochemistry Laboratory, Disease-specific Exemption, Diabetes Outpatient Clinics, and Mortality databases. Using these data, we estimated crude prevalence on December 31st, 2009 by sex, age groups, and type of diabetes. There were 25,425 ascertained prevalent cases on December 31st, 2009. Drug Dispensation and Exemption databases made the greatest contribution to prevalence. Analyzing overlapping sources, more than 80% of cases were reported by at least two sources. Crude prevalence was 4.8% and 5.9% for the whole population and for people aged 18 years and over, respectively. Males accounted for 53.6%. Type 1 diabetes accounted for 3.8% of cases, while people with Type 2 diabetes were the overriding majority (91.2%), and Diabetes Outpatient Clinics treated 75.4% of people with Type 2 diabetes. The Register is able to quantify the burden of disease, the first step in planning, implementing, and monitoring appropriate interventions. All data sources contributed to completeness and/or accuracy of the Register. Although all cases are identified by deterministic record linkage, manual revision and General Practitioner involvement are still necessary when information is insufficient or conflicting. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Meijer, Erik; Rohwedder, Susann; Wansbeek, Tom
2012-01-01
Survey data on earnings tend to contain measurement error. Administrative data are superior in principle, but they are worthless in case of a mismatch. We develop methods for prediction in mixture factor analysis models that combine both data sources to arrive at a single earnings figure. We apply the methods to a Swedish data set. Our results show that register earnings data perform poorly if there is a (small) probability of a mismatch. Survey earnings data are more reliable, despite their measurement error. Predictors that combine both and take conditional class probabilities into account outperform all other predictors.
NASA Astrophysics Data System (ADS)
Eppenhof, Koen A. J.; Pluim, Josien P. W.
2017-02-01
Error estimation in medical image registration is valuable when validating, comparing, or combining registration methods. To validate a nonlinear image registration method, ideally the registration error should be known for the entire image domain. We propose a supervised method for the estimation of a registration error map for nonlinear image registration. The method is based on a convolutional neural network that estimates the norm of the residual deformation from patches around each pixel in two registered images. This norm is interpreted as the registration error, and is defined for every pixel in the image domain. The network is trained using a set of artificially deformed images. Each training example is a pair of images: the original image, and a random deformation of that image. No manually labeled ground truth error is required. At test time, only the two registered images are required as input. We train and validate the network on registrations in a set of 2D digital subtraction angiography sequences, such that errors up to eight pixels can be estimated. We show that for this range of errors the convolutional network is able to learn the registration error in pairs of 2D registered images at subpixel precision. Finally, we present a proof of principle for the extension to 3D registration problems in chest CTs, showing that the method has the potential to estimate errors in 3D registration problems.
Wendsche, Johannes; Hacker, Winfried; Wegge, Jürgen; Rudolf, Matthias
2016-10-01
We investigated how two types of care setting (home care and nursing home) and type of ownership (for-profit vs. public/non-profit) of geriatric care services interacted in influencing registered nurses' intention to give up their profession. In prior research, employment in for-profit-organizations, high job demands, and low job control were important antecedents of nurses' intent to leave. However, the impact of care setting on these associations was inconclusive. Therefore, we tested a mediated moderation model predicting that adverse work characteristics would drive professional leaving intentions, particularly in for-profit services and in nursing homes. A representative German sample of 304 registered nurses working in 78 different teams participated in our cross-sectional study. As predicted, lower job control and higher job demands were associated with higher professional leaving intentions, and nurses reported higher job demands in public/non-profit care than in for-profit care, and in nursing homes compared to home care. Overall, RNs in nursing homes and home care reported similar intent to leave, but in for-profit settings only, nurses working in nursing homes reported higher professional leaving intentions than did nurses in home care, which was linked to lower job control in the for-profit nursing home setting, supporting mediated moderation. Taken together, our results indicate that the interplay of care setting and type of ownership is important when explaining nurses' intentions to give up their profession. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-10
...-01] Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter... Technology (NIST) seeks comments on Draft NISTIR 7823, Advanced Metering Infrastructure Smart Meter.... Electronic comments should be sent to: Michaela Iorga at [email protected]nist.gov , with a Subject line...
The Peak Flow Working Group: test of portable peak flow meters by explosive decompression.
Pedersen, O F; Miller, M R
1997-02-01
In 1991, 50 new Vitalograph peak flow meters and 27 previously used mini-Wright peak flow meters were tested at three peak flows by use of a calibrator applying explosive decompression. The mini-Wright peak flow meters were also compared with eight new meters. For both makes of meter there was an excellent within-meter and between-meter variation. The accuracy, however, was poor, with a maximal overestimation of true flows of 50 and 70 L.min-1 in the interval from 200 to 400 L.min-1 for the Vitalograph and mini-Wright meters, respectively. The deviation is explained by the physical characteristics of the variable orifice peak flow meters. They have been supplied with equidistant scales, which give non-linear readings.
NASA Astrophysics Data System (ADS)
Vericat, Damià; Narciso, Efrén; Béjar, Maria; Tena, Álvaro; Brasington, James; Gibbins, Chris; Batalla, Ramon J.
2014-05-01
Digital Terrain Models are fundamental to characterise landscapes, to support numerical modelling and to monitor topographic changes. Recent advances in topography, remote sensing and geomatics are providing new opportunities to obtain high density/quality and rapid topographic data. In this paper we present an integrated methodology to rapidly obtain reach scale topographic models of fluvial systems. This methodology has been tested and is being applied to develop event-scale terrain models of a 11-km river reach in the highly dynamic Upper Cinca (NE Iberian Peninsula). This research is conducted in the background of the project MorphSed. The methodology integrates (a) the acquisition of dense point clouds of the exposed floodplain (aerial photography and digital photogrammetry); (b) the registration of all observations to the same coordinate system (using RTK-GPS surveyed GCPs); (c) the acquisition of bathymetric data (using aDcp measurements integrated with RTK-GPS); (d) the intelligent decimation of survey observations (using the open source TopCat toolkit) and, finally, (e) data fusion (elaborating Digital Elevation Models). In this paper special emphasis is given to the acquisition and registration of point clouds. 3D point clouds are obtained from aerial photography and by means of automated digital photogrammetry. Aerial photographs are taken at 275 meters above the ground by means of a SLR digital camera manually operated from an autogyro. Four flight paths are defined in order to cover the 11 km long and 500 meters wide river reach. A total of 45 minutes are required to fly along these paths. Camera has been previously calibrated with the objective to ensure image resolution at around 5 cm. A total of 220 GCPs are deployed and RTK-GPS surveyed before the flight is conducted. Two people and one full workday are necessary to deploy and survey the full set of GCPs. Field data acquisition may be finalised in less than 2 days. Structure-from-Motion is subsequently applied in the lab using Agisoft PhotoScan, photographs are aligned and a 3d point cloud is generated. GCPs are used to geo-register all point clouds. This task may be time consuming since GCPs need to be identified in at least two of the pictures. A first automatic identification of GCPs positions is performed in the rest of the photos, although user supervision is necessary. Preliminary results show as geo-registration errors between 0.08 and and 0.10 meters can be obtained. The number of GCPs is being degraded and the quality of the point cloud assessed based on check points (the extracted GCPs). A critical analysis of GCPs density and scene locations is being performed (results in preparation). The results show that automated digital photogrammetry may provide new opportunities in the acquisition of topographic data at multiple temporal and spatial scales, being competitive with other more expensive techniques that, in turn, may require much more time to acquire field observations. SfM offers new opportunities to develop event-scale terrain models of fluvial systems suitable for hydraulic modelling and to study topographic change in highly dynamic environments.
On the use of InSAR technology to assess land subsidence in Jakarta coastal flood plain
NASA Astrophysics Data System (ADS)
Koudogbo, Fifame; Duro, Javier; Garcia Robles, Javier; Arnaud, Alain; Abidin, Hasanuddin Z.
2014-05-01
Jakarta is the capital of Indonesia and is home to approximately 10 million people on the coast of the Java Sea. It is situated on the northern coastal alluvial plane of Java which shares boundaries with West Java Province in the south and in the east, and with Banten Province in the west. The Capital District of Jakarta (DKI) sits in the lowest lying areas of the basin. Its topography varies, with the northern part just meters above current sea level and lying on a flood plain. Subsequently, this portion of the city frequently floods. The southern part of the city is hilly. Thirteen major rivers flow through Jakarta to the Java Sea. The Ciliwung River is the most significant river and divides the city West to East. In the last three decades, urban growing of Jakarta has been very fast in sectors as industry, trade, transportation, real estate, among others. This exponential development has caused several environmental issues; land subsidence is one of them. Subsidence in Jakarta has been known since the early part of the 20th century. It is mainly due to groundwater extraction, the fast development (construction load), soil natural consolidation and tectonics. Evidence of land subsidence exists through monitoring with GPS, level surveys and InSAR investigations. InSAR states for "Interferometric Synthetic Aperture Radar". Its principle is based on comparing the distance between the satellite and the ground in consecutive satellite passes over the same area on the Earth's surface. Radar satellites images record, with very high precision, the distance travelled by the radar signal that is emitted by the satellite is registered. When this distance is compared through time, InSAR technology can provide highly accurate ground deformation measurements. ALTAMIRA INFORMATION, company specialized in ground motion monitoring, has developed GlobalSARTM, which combines several processing techniques and algorithms based on InSAR technology, to achieve ground motion measurements with millimetric precision and high accuracy. World Bank studies conservatively estimate land subsidence in Jakarta occurring at an average rate of 5 cm per year, and in some areas, over 1 meters was already observed. Recent studies of land subsidence found that while typical subsidence rates were 7.5-10 cm a year, in localized areas of North Jakarta subsidence in the range 15-25 cm a year was occurring, which if sustained, would result in them sinking to 4 to 5 meters below sea level by 2025. Land subsidence will require major interventions, including increased pumping, dikes and most likely introducing major infrastructure investment for sea defense. With the increasing prevalence of Earth Observation, the World Bank and the European Space Agency have set up a partnership that aims at highlighting the potential of EO information to support the monitoring and management of World Bank projects. In this framework ALTAMIRA INFORMATION has assessed land subsidence in Jakarta. Impressive results have been obtained by providing high resolution measurements which can help in improving the characterization of the subsidence mechanisms.
Z-Earth: 4D topography from space combining short-baseline stereo and lidar
NASA Astrophysics Data System (ADS)
Dewez, T. J.; Akkari, H.; Kaab, A. M.; Lamare, M. L.; Doyon, G.; Costeraste, J.
2013-12-01
The advent of free-of-charge global topographic data sets SRTM and Aster GDEM have enabled testing a host of geoscience hypotheses. Availability of such data is now considered standard, and though resolved at 30-m to 90-m pixel size, they are today regarded as obsolete and inappropriate given the regularly updated sub-meter imagery coming through web services like Google Earth. Two features will thus help meet the current topographic data needs of the Geoscience communities: field-scale-compatible elevation datasets (i.e. meter-scale digital models and sub-meter elevation precision) and provision for regularly updated topography to tackle earth surface changes in 4D, while retaining the key for success: data availability at no charge. A new space borne instrumental concept called Z-Earth has undergone phase 0 study at CNES, the French space agency to fulfill these aims. The scientific communities backing this proposal are that of natural hazards, glaciology and biomass. The system under study combines a short-baseline native stereo imager and a lidar profiler. This combination provides spatially resolved elevation swaths together with absolute along-track elevation control point profiles. Acquisition is designed for revisit time better than a year. Intended products not only target single pass digital surface models, color orthoimages and small footprint full-wave-form lidar profiles to update existing topographic coverage, but also time series of them. 3D change detection targets centimetre-scale horizontal precision and metric vertical precision, in complement of -now traditional- spectral change detection. To assess the actual concept value, two real-size experiments were carried out. We used sub-meter-scale Pleiades panchromatic stereo-images to generate digital surface models and check them against dense airborne lidar coverages, one heliborne set purposely flown in Corsica (50-100pts/sq.m) and a second one retrieved from OpenTopography.org (~10pts/sq.m.). In Corsica, over a challenging 45-degree-grade tree-covered mountain side, the Pleiades 2-m-grid-posting digital surface model described the topography with a median error of -4.75m +/-2.59m (NMAD). A planimetric bias between both datasets was found to be about 7m to the South. This planimetric misregistration, though well within Pleiades specifications, partly explains the dramatic effect on elevation difference. In the Redmond area (eastern Oregon), a very gentle desert landscape, elevation differences also contained a vertical median bias of -4.02m+/-1.22m (NMAD). Though here, sub-pixel planimetric registration between stereo DSM and lidar coverage was enforced. This real-size experiment hints that sub-meter accuracy for 2-m-grid-posting DSM is an achievable goal when combining stereoimaging and lidar.