Sample records for meter systems usability

  1. Development of Bottom Oil Recovery Systems. Revised

    DTIC Science & Technology

    2014-02-01

    designed a recovery system based on dredging technology. It could handle harsh wind /wave conditions but has significant logistical requirements, due...Knots m/s Meter(s) per second M/T Motor tanker M/V Motor vessel m Meter or meters m2 Square meters m3 Cubic meters MBTA Migratory Bird ...usable for some bottom types. Wind 30 kts (45-kt gusts) Wave 0-2m (0-5ft) Current 0-2 kts Lightning ɝmiles Minimum depth of about 9m (30 ft

  2. Seamless recording of glucometer measurements among older experienced diabetic patients - A study of perception and usability.

    PubMed

    Rasche, Peter; Mertens, Alexander; Miron-Shatz, Talya; Berzon, Corinne; Schlick, Christopher M; Jahn, Michael; Becker, Stefan

    2018-01-01

    Self-measurement and documentation of blood-glucose are critical elements of diabetes management, particularly in regimes including insulin. In this study, we analyze the usability of iBG-STAR, the first blood glucose meter connectable to a smartphone. This technology records glucometer measurements, removing the burden of documentation from diabetic patients. This study assesses the potential for implementation of iBG-STAR in routine care. Twelve long-term diabetic patients (4 males; median age of 66.5 years) were enrolled in the study. N = 4/12 reported diabetic polyneuropathy. Reported subjective mental workload for all tasks related to iBG-STAR was on average lower than 12 points, corresponding to the verbal code 'nearly no effort needed'. A "Post Study System Usability Questionnaire", evaluated the glucometer at an average value of 2.06 (SD = 1.02) on a 7-Likert-scale (1 = 'I fully agree' to 7 = 'I completely disagree') for usability. These results represent a positive user-experience. Patients with polyneuropathy may experience physical difficulties in completing the tasks, thereby affecting usability. Technologically savvy patients (n = 6) with a positive outlook on diabetes assessed the product as a suitable tool for themselves and would recommend to other diabetic patients. The main barrier to regular use was treating physicians' inability to retrieve digitally recorded data. This barrier was due to a shortcoming in interoperability of mobile devices and medical information systems.

  3. Design and Testing of a One-Meter Membrane Mirror with Active Boundary Control (Conference Proceedings)

    DTIC Science & Technology

    2005-08-01

    One type of setup looked into in the past has been the lenticular design, which consists of a clear canopy attached to a reflective film that uses...class lenticular membrane mirror system utilizing active boundary control and stress-coating applications to form a usable aperture for visible...imaging applications. Keywords: Membrane mirror, boundary control, lenticular , lightweight 1. INTRODUCTION Analysis has been conducted to

  4. Blood Glucose Meters and Accessibility to Blind and Visually Impaired People

    PubMed Central

    Burton, Darren M.; Enigk, Matthew G.; Lilly, John W.

    2012-01-01

    In 2007, five blood glucose meters (BGMs) were introduced with integrated speech output necessary for use by persons with vision loss. One of those five meters had fully integrated speech output, allowing a person with vision loss independence in accessing all features and functions of the meter. In comparison, 13 BGMs with integrated speech output were available in 2011. Accessibility attributes of these 11 meters were tabulated and product design features examined. All 13 meters were found to be usable by persons with vision loss to obtain a blood glucose measurement. However, only 4 of them featured the fully integrated speech output necessary for a person with vision loss to access all features and functions independently. PMID:22538131

  5. Blood glucose meters and accessibility to blind and visually impaired people.

    PubMed

    Burton, Darren M; Enigk, Matthew G; Lilly, John W

    2012-03-01

    In 2007, five blood glucose meters (BGMs) were introduced with integrated speech output necessary for use by persons with vision loss. One of those five meters had fully integrated speech output, allowing a person with vision loss independence in accessing all features and functions of the meter. In comparison, 13 BGMs with integrated speech output were available in 2011. Accessibility attributes of these 11 meters were tabulated and product design features examined. All 13 meters were found to be usable by persons with vision loss to obtain a blood glucose measurement. However, only 4 of them featured the fully integrated speech output necessary for a person with vision loss to access all features and functions independently. © 2012 Diabetes Technology Society.

  6. All Optical Solution for Free Space Optics Point to Point Links

    NASA Astrophysics Data System (ADS)

    Hirayama, Daigo

    Optical network systems are quickly replacing electrical network systems. Optical systems provide better bandwidth, faster data rates, better security to networks, and are less susceptible to noise. Free Space Optics (systems) still rely on numerous electrical systems such as the modulation and demodulation systems to convert optical signals to electrical signals for the transmitting laser. As the concept of the entirely optical network becomes more realizable, the electrical components of the FSO system will become a hindrance to communications. The focus of this thesis is to eliminate the electrical devices for the FSO point to point links by replacing them with optical devices. The concept is similar to an extended beam connector. However, where an extended beam connector deals with a gap of a few millimeters, my focus looks at distances from 100 meters to one kilometer. The aim is to achieve a detectable signal of 1nW at a distance of 500 meters at a wavelength of 1500-1600nm. This leads to application in building to building links and mobile networks. The research examines the design of the system in terms of generating the wave, the properties of the fiber feeding the wave, and the power necessary to achieve a usable distance. The simulation is executed in Code V by Synopsys, which is an industry standard to analyze optical systems. A usable device with a range of around 500m was achieved with an input power of 1mW. The approximations of the phase function resulted in some aberrations to the profile of the beam, but were not very detrimental to the function of the device. The removal of electrical devices from a FSO point to point link decreased the power used to establish the link and decreased the cost.

  7. Usability analysis of 2D graphics software for designing technical clothing.

    PubMed

    Teodoroski, Rita de Cassia Clark; Espíndola, Edilene Zilma; Silva, Enéias; Moro, Antônio Renato Pereira; Pereira, Vera Lucia D V

    2012-01-01

    With the advent of technology, the computer became a working tool increasingly present in companies. Its purpose is to increase production and reduce the inherent errors in manual production. The aim of this study was to analyze the usability of 2D graphics software in creating clothing designs by a professional during his work. The movements of the mouse, keyboard and graphical tools were monitored in real time by software Camtasia 7® installed on the user's computer. To register the use of mouse and keyboard we used auxiliary software called MouseMeter®, which quantifies the number of times they pressed the right, middle and left mouse's buttons, the keyboard and also the distance traveled in meters by the cursor on the screen. Data was collected in periods of 15 minutes, 1 hour and 8 hours, consecutively. The results showed that the job is considered repetitive and high demands physical efforts, which can lead to the appearance of repetitive strain injuries. Thus, the goal of minimizing operator efforts and thereby enhance the usability of the examined tool, becomes imperative to replace the mouse by a device called tablet, which also offers an electronic pen and a drawing platform for design development.

  8. OPTOTRAK: at last a system with resolution of 10 μm (Abstract Only)

    NASA Astrophysics Data System (ADS)

    Crouch, David G.; Kehl, L.; Krist, J. R.

    1990-08-01

    Northern Digital's first active marker point measurement system, the WATSMART, was begun in 1983. Development ended in 1985 with the manufacture of a highly accurate system, which achieved .15 to .25 mm accuracies in three dimensions within a .75-meter cube. Further improvements in accuracy were rendered meaningless, and a great obstacle to usability was presented by a surplus light problem somewhat incorrectly known as "the reflection problem". In 1985, development of a new system to overcome "the reflection problem" was begun. The advantages and disadvantages involved in the use of active versus passive markers were considered. The implications of using a CCD device as the imaging element in a precision measurement device were analyzed, as were device characteristics such as dynamic range, peak readout noise and charge transfer efficiency. A new type of lens was also designed The end result, in 1988, was the first OPTOTRAK system. This system produces three-dimensional data in real-time and is not at all affected by reflections. Accuracies of 30 microns have been achieved in a 1-meter volume. Each two-dimensional camera actually has two separate, one-dimensional, CCD elements and two separate anamorphic lenses. It can locate a point from 1-8 meters away with a resolution of 1 part in 64,000 and an accuracy of 1 part in 20,000 over the field of view.

  9. Blood Glucose Meters That Are Accessible to Blind and Visually Impaired Persons

    PubMed Central

    Uslan, Mark M.; Burton, Darren M.; Clements, Charles W.

    2008-01-01

    Blood glucose meters (BGMs) that can be used nonvisually or with a visual limitation were introduced in the mid-1990s, but it was not until 2006 and 2007 that a new set of meters with accessibility features were introduced: Prodigy, Prodigy Autocode, and Prodigy Voice (Diagnostic Devices, Charlotte, NC), and Advocate and Advocate Redi-Code (TaiDoc, Taiwan). Accessibility attributes of the newly introduced BGMs were tabulated, and product design features were examined and documented. The Prodigy Voice was found to be the only one of these new BGMs that is fully usable by blind and visually impaired persons. PMID:19885356

  10. Blood glucose meters that are accessible to blind and visually impaired persons.

    PubMed

    Uslan, Mark M; Burton, Darren M; Clements, Charles W

    2008-03-01

    Blood glucose meters (BGMs) that can be used nonvisually or with a visual limitation were introduced in the mid-1990s, but it was not until 2006 and 2007 that a new set of meters with accessibility features were introduced: Prodigy, Prodigy Autocode, and Prodigy Voice (Diagnostic Devices, Charlotte, NC), and Advocate and Advocate Redi-Code (TaiDoc, Taiwan). Accessibility attributes of the newly introduced BGMs were tabulated, and product design features were examined and documented. The Prodigy Voice was found to be the only one of these new BGMs that is fully usable by blind and visually impaired persons.

  11. Handheld Multi-Gas Meters Assessment Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Gustavious; Wald-Hopkins, Mark David; Obrey, Stephen J.

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria andmore » scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.« less

  12. La contribution des astronomes aux mesures de précision.

    NASA Astrophysics Data System (ADS)

    Debarbat, S.

    The system for astronomical constants includes the astronomical unit, the velocity of light and the light-time for the unit distance in the metric system. In France, at least from the 17th century, scientists had in mind to unify the units. But it is not before the time of the French Revolution that it was succeeded to adopt a unified system based on the metre. Measurements were made of an arc of meridian, from Dunkirk to Barcelona to determine the new unit as the fraction of 1 over 107 of a quarter of any part of the Earth from the north pole to the equator. On the occasion of the bicentenary of the nomenclature of the metric system (1795), the Paris Observatory has presented during more than six months in 1995, mostly for students, manuscripts, documents related to the subject, in its galeries on the first floor of the Perrault building. The exhibition ended with the 1960 and 1983 definitions of the meter to which the Paris Observatory has contributed. For astronomers it was recalled the reason for which the Angström had to be considered as not more usable, being only close to the fraction 1/1010 of the meter.

  13. Design of a CAN bus interface for photoelectric encoder in the spaceflight camera

    NASA Astrophysics Data System (ADS)

    Sun, Ying; Wan, Qiu-hua; She, Rong-hong; Zhao, Chang-hai; Jiang, Yong

    2009-05-01

    In order to make photoelectric encoder usable in a spaceflight camera which adopts CAN bus as the communication method, CAN bus interface of the photoelectric encoder is designed in this paper. CAN bus interface hardware circuit of photoelectric encoder consists of CAN bus controller SJA 1000, CAN bus transceiver TJA1050 and singlechip. CAN bus interface controlling software program is completed in C language. A ten-meter shield twisted pair line is used as the transmission medium in the spaceflight camera, and speed rate is 600kbps.The experiments show that: the photoelectric encoder with CAN bus interface which has the advantages of more reliability, real-time, transfer rate and transfer distance overcomes communication line's shortcomings of classical photoelectric encoder system. The system works well in automatic measuring and controlling system.

  14. Increasing EHR system usability through standards: Conformance criteria in the HL7 EHR-system functional model.

    PubMed

    Meehan, Rebecca A; Mon, Donald T; Kelly, Kandace M; Rocca, Mitra; Dickinson, Gary; Ritter, John; Johnson, Constance M

    2016-10-01

    Though substantial work has been done on the usability of health information technology, improvements in electronic health record system (EHR) usability have been slow, creating frustration, distrust of EHRs and the use of potentially unsafe work-arounds. Usability standards could be part of the solution for improving EHR usability. EHR system functional requirements and standards have been used successfully in the past to specify system behavior, the criteria of which have been gradually implemented in EHR systems through certification programs and other national health IT strategies. Similarly, functional requirements and standards for usability can help address the multitude of sequelae associated with poor usability. This paper describes the evidence-based functional requirements for usability contained in the Health Level Seven (HL7) EHR System Functional Model, and the benefits of open and voluntary EHR system usability standards. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Towards a Usability and Error "Safety Net": A Multi-Phased Multi-Method Approach to Ensuring System Usability and Safety.

    PubMed

    Kushniruk, Andre; Senathirajah, Yalini; Borycki, Elizabeth

    2017-01-01

    The usability and safety of health information systems have become major issues in the design and implementation of useful healthcare IT. In this paper we describe a multi-phased multi-method approach to integrating usability engineering methods into system testing to ensure both usability and safety of healthcare IT upon widespread deployment. The approach involves usability testing followed by clinical simulation (conducted in-situ) and "near-live" recording of user interactions with systems. At key stages in this process, usability problems are identified and rectified forming a usability and technology-induced error "safety net" that catches different types of usability and safety problems prior to releasing systems widely in healthcare settings.

  16. Human Factors in the Large: Experiences from Denmark, Finland and Canada in Moving Towards Regional and National Evaluations of Health Information System Usability. Contribution of the IMIA Human Factors Working Group.

    PubMed

    Kushniruk, A; Kaipio, J; Nieminen, M; Hyppönen, H; Lääveri, T; Nohr, C; Kanstrup, A M; Berg Christiansen, M; Kuo, M-H; Borycki, E

    2014-08-15

    The objective of this paper is to explore approaches to understanding the usability of health information systems at regional and national levels. Several different methods are discussed in case studies from Denmark, Finland and Canada. They range from small scale qualitative studies involving usability testing of systems to larger scale national level questionnaire studies aimed at assessing the use and usability of health information systems by entire groups of health professionals. It was found that regional and national usability studies can complement smaller scale usability studies, and that they are needed in order to understand larger trends regarding system usability. Despite adoption of EHRs, many health professionals rate the usability of the systems as low. A range of usability issues have been noted when data is collected on a large scale through use of widely distributed questionnaires and websites designed to monitor user perceptions of usability. As health information systems are deployed on a widespread basis, studies that examine systems used regionally or nationally are required. In addition, collection of large scale data on the usability of specific IT products is needed in order to complement smaller scale studies of specific systems.

  17. Human Factors in the Large: Experiences from Denmark, Finland and Canada in Moving Towards Regional and National Evaluations of Health Information System Usability

    PubMed Central

    Kaipio, J.; Nieminen, M.; Hyppönen, H.; Lääveri, T.; Nohr, C.; Kanstrup, A. M.; Berg Christiansen, M.; Kuo, M.-H.; Borycki, E.

    2014-01-01

    Summary Objectives The objective of this paper is to explore approaches to understanding the usability of health information systems at regional and national levels. Methods Several different methods are discussed in case studies from Denmark, Finland and Canada. They range from small scale qualitative studies involving usability testing of systems to larger scale national level questionnaire studies aimed at assessing the use and usability of health information systems by entire groups of health professionals. Results It was found that regional and national usability studies can complement smaller scale usability studies, and that they are needed in order to understand larger trends regarding system usability. Despite adoption of EHRs, many health professionals rate the usability of the systems as low. A range of usability issues have been noted when data is collected on a large scale through use of widely distributed questionnaires and websites designed to monitor user perceptions of usability. Conclusion As health information systems are deployed on a widespread basis, studies that examine systems used regionally or nationally are required. In addition, collection of large scale data on the usability of specific IT products is needed in order to complement smaller scale studies of specific systems. PMID:25123725

  18. Usability Methods for Ensuring Health Information Technology Safety: Evidence-Based Approaches. Contribution of the IMIA Working Group Health Informatics for Patient Safety.

    PubMed

    Borycki, E; Kushniruk, A; Nohr, C; Takeda, H; Kuwata, S; Carvalho, C; Bainbridge, M; Kannry, J

    2013-01-01

    Issues related to lack of system usability and potential safety hazards continue to be reported in the health information technology (HIT) literature. Usability engineering methods are increasingly used to ensure improved system usability and they are also beginning to be applied more widely for ensuring the safety of HIT applications. These methods are being used in the design and implementation of many HIT systems. In this paper we describe evidence-based approaches to applying usability engineering methods. A multi-phased approach to ensuring system usability and safety in healthcare is described. Usability inspection methods are first described including the development of evidence-based safety heuristics for HIT. Laboratory-based usability testing is then conducted under artificial conditions to test if a system has any base level usability problems that need to be corrected. Usability problems that are detected are corrected and then a new phase is initiated where the system is tested under more realistic conditions using clinical simulations. This phase may involve testing the system with simulated patients. Finally, an additional phase may be conducted, involving a naturalistic study of system use under real-world clinical conditions. The methods described have been employed in the analysis of the usability and safety of a wide range of HIT applications, including electronic health record systems, decision support systems and consumer health applications. It has been found that at least usability inspection and usability testing should be applied prior to the widespread release of HIT. However, wherever possible, additional layers of testing involving clinical simulations and a naturalistic evaluation will likely detect usability and safety issues that may not otherwise be detected prior to widespread system release. The framework presented in the paper can be applied in order to develop more usable and safer HIT, based on multiple layers of evidence.

  19. Evaluation of expert system application based on usability aspects

    NASA Astrophysics Data System (ADS)

    Munaiseche, C. P. C.; Liando, O. E. S.

    2016-04-01

    Usability usually defined as a point of human acceptance to a product or a system based on understands and right reaction to an interface. The performance of web application has been influence by the quality of the interface of that web to supporting information transfer process. Preferably, before the applications of expert systems were installed in the operational environment, these applications must be evaluated first by usability testing. This research aimed to measure the usability of the expert system application using tasks as interaction media. This study uses an expert system application to diagnose skin disease in human using questionnaire method which utilize the tasks as interaction media in measuring the usability. Certain tasks were executed by the participants in observing usability value of the application. The usability aspects observed were learnability, efficiency, memorability, errors, and satisfaction. Each questionnaire question represent aspects of usability. The results present the usability value for each aspect and the total average merit for all the five-usability aspect was 4.28, this indicated that the tested expert system application is in the range excellent for the usability level, so the application can be implemented as the operated system by user. The main contribution of the study is the research became the first step in using task model in the usability evaluation for the expert system application software.

  20. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System.

    PubMed

    Marcilly, R; Ammenwerth, E; Roehrer, E; Pelayo, S; Vasseur, F; Beuscart-Zéphir, M-C

    2015-08-13

    Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology.

  1. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System

    PubMed Central

    Ammenwerth, E.; Roehrer, E.; Pelayo, S.; Vasseur, F.; Beuscart-Zéphir, M.-C.

    2015-01-01

    Summary Objectives Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. Methods A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Results Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Conclusion Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology. PMID:26123906

  2. Applying usability methods to identify health literacy issues: an example using a Personal Health Record.

    PubMed

    Monkman, Helen; Kushniruk, Andre

    2013-01-01

    The prevalence of consumer health information systems is increasing. However, usability and health literacy impact both the value and adoption of these systems. Health literacy and usability are closely related in that systems may not be used accurately if users cannot understand the information therein. Thus, it is imperative to focus on mitigating the demands on health literacy in consumer health information systems. This study modified two usability evaluation methods (heuristic evaluation and usability testing) to incorporate the identification of potential health literacy issues in a Personal Health Record (PHR). Heuristic evaluation is an analysis of a system performed by a usability specialist who evaluates how well the system abides by usability principles. In contrast, a usability test involves a post hoc analysis of a representative user interacting with the system. These two methods revealed several health literacy issues and suggestions to ameliorate them were made. Thus, it was demonstrated that usability methods could be successfully augmented for the purpose of investigating health literacy issues. To improve users' health knowledge, the adoption of consumer health information systems, and the accuracy of the information contained therein, it is encouraged that usability methods be applied with an added focus on health literacy.

  3. Innovative telemonitoring system for cardiology: from science to routine operation.

    PubMed

    Kastner, P; Morak, J; Modre, R; Kollmann, A; Ebner, C; Fruhwald, Fm; Schreier, G

    2010-01-01

    Results of the Austrian MOBITEL (MOBIle phone based TELemonitoring for heart failure patients) trial indicate that home-based telemonitoring improves outcome of chronic heart failure (CHF) patients and reduces both frequency and duration of hospitalizations. Based on lessons learned, we assessed the weak points to clear the way for routine operations. We analyzed the system with respect to recommendations of the ESC Guidelines and experiences gained throughout the trial to identify potential improvements. The following components have been identified: a patient terminal with highest usability, integrated way to document drug-intake and well-being, and automated event detection for worsening of CHF. As a consequence the system was extended by Near Field Communication (NFC) technology and by an event management tool. Usability evaluation with 30 adults (14f, median 51y. IQR[45-65]) showed that 21 (8f) were able to immediately operate the system after reading a step-by-step manual. Eight (6f) needed one time demonstration and one man (80y) failed to operate the blood pressure meter. Routine operation of the revised system started in March 2009. Within 9 months, 15 patients (4f, median 74y. IQR[71-83], all NYHA-III) transmitted 17,149 items. 43 events were detected because of body weight gain of more then 2kg within 2 days. 49 therapy adjustments were documented. Three patients stopped using the system, two (1f) because of non-compliance and one (m, 82y) because of death. Overall, the rate of adherence to daily data transfer was 78%. First results confirm the applicability of the revised telemonitoring system in routine operation.

  4. Usability study of a computer-based self-management system for older adults with chronic diseases.

    PubMed

    Or, Calvin; Tao, Da

    2012-11-08

    Usability can influence patients' acceptance and adoption of a health information technology. However, little research has been conducted to study the usability of a self-management health care system, especially one geared toward elderly patients. This usability study evaluated a new computer-based self-management system interface for older adults with chronic diseases, using a paper prototype approach. Fifty older adults with different chronic diseases participated. Two usability evaluation methods were involved: (1) a heuristics evaluation and (2) end-user testing with a think-aloud testing method, audio recording, videotaping, and interviewing. A set of usability metrics was employed to determine the overall system usability, including task incompletion rate, task completion time, frequency of error, frequency of help, satisfaction, perceived usefulness, and perceived ease of use. Interviews were used to elicit participants' comments on the system design. The quantitative data were analyzed using descriptive statistics and the qualitative data were analyzed for content. The participants were able to perform the predesigned self-management tasks with the current system design and they expressed mostly positive responses about the perceived usability measures regarding the system interface. However, the heuristics evaluation, performance measures, and interviews revealed a number of usability problems related to system navigation, information search and interpretation, information presentation, and readability. Design recommendations for further system interface modifications were discussed. This study verified the usability of the self-management system developed for older adults with chronic diseases. Also, we demonstrated that our usability evaluation approach could be used to quickly and effectively identify usability problems in a health care information system at an early stage of the system development process using a paper prototype. Conducting a usability evaluation is an essential step in system development to ensure that the system features match the users' true needs, expectations, and characteristics, and also to minimize the likelihood of the users committing user errors and having difficulties using the system.

  5. Usability Study of a Computer-Based Self-Management System for Older Adults with Chronic Diseases

    PubMed Central

    Tao, Da

    2012-01-01

    Background Usability can influence patients’ acceptance and adoption of a health information technology. However, little research has been conducted to study the usability of a self-management health care system, especially one geared toward elderly patients. Objective This usability study evaluated a new computer-based self-management system interface for older adults with chronic diseases, using a paper prototype approach. Methods Fifty older adults with different chronic diseases participated. Two usability evaluation methods were involved: (1) a heuristics evaluation and (2) end-user testing with a think-aloud testing method, audio recording, videotaping, and interviewing. A set of usability metrics was employed to determine the overall system usability, including task incompletion rate, task completion time, frequency of error, frequency of help, satisfaction, perceived usefulness, and perceived ease of use. Interviews were used to elicit participants’ comments on the system design. The quantitative data were analyzed using descriptive statistics and the qualitative data were analyzed for content. Results The participants were able to perform the predesigned self-management tasks with the current system design and they expressed mostly positive responses about the perceived usability measures regarding the system interface. However, the heuristics evaluation, performance measures, and interviews revealed a number of usability problems related to system navigation, information search and interpretation, information presentation, and readability. Design recommendations for further system interface modifications were discussed. Conclusions This study verified the usability of the self-management system developed for older adults with chronic diseases. Also, we demonstrated that our usability evaluation approach could be used to quickly and effectively identify usability problems in a health care information system at an early stage of the system development process using a paper prototype. Conducting a usability evaluation is an essential step in system development to ensure that the system features match the users’ true needs, expectations, and characteristics, and also to minimize the likelihood of the users committing user errors and having difficulties using the system. PMID:23612015

  6. Perceived Usability Evaluation of Learning Management Systems: Empirical Evaluation of the System Usability Scale

    ERIC Educational Resources Information Center

    Orfanou, Konstantina; Tselios, Nikolaos; Katsanos, Christos

    2015-01-01

    Perceived usability affects greatly student's learning effectiveness and overall learning experience, and thus is an important requirement of educational software. The System Usability Scale (SUS) is a well-researched and widely used questionnaire for perceived usability evaluation. However, surprisingly few studies have used SUS to evaluate the…

  7. Implementing Child-focused Activity Meter Utilization into the Elementary School Classroom Setting Using a Collaborative Community-based Approach.

    PubMed

    Lynch, B A; Jones, A; Biggs, B K; Kaufman, T; Cristiani, V; Kumar, S; Quigg, S; Maxson, J; Swenson, L; Jacobson, N

    2015-12-01

    The prevalence of pediatric obesity has increased over the past 3 decades and is a pressing public health program. New technology advancements that can encourage more physical in children are needed. The Zamzee program is an activity meter linked to a motivational website designed for children 8-14 years of age. The objective of the study was to use a collaborative approach between a medical center, the private sector and local school staff to assess the feasibility of using the Zamzee Program in the school-based setting to improve physical activity levels in children. This was a pilot 8-week observational study offered to all children in one fifth grade classroom. Body mass index (BMI), the amount of physical activity by 3-day recall survey, and satisfaction with usability of the Zamzee Program were measured pre- and post-study. Out of 11 children who enrolled in the study, 7 completed all study activities. In those who completed the study, the median (interquartile range) total activity time by survey increased by 17 (1042) minutes and the BMI percentile change was 0 (8). Both children and their caregivers found the Zamzee Activity Meter (6/7) and website (6/7) "very easy" or "easy" to use. The Zamzee Program was found to be usable but did not significantly improve physical activity levels or BMI. Collaborative obesity intervention projects involving medical centers, the private sector and local schools are feasible but the effectiveness needs to be evaluated in larger-scale studies.

  8. Measuring AT Usability with the Modified System Usability Scale (SUS).

    PubMed

    Friesen, Emma L

    2017-01-01

    The modified System Usability Scale (SUS) is a widely used generic measure of product usability. This study concerns the usability of mobile shower commodes using correlations between the SUS and AT device-specific measures. Results suggest the modified SUS, and corresponding adjective-anchored rating scale, are appropriate for measuring MSC usability, and have potential for use with other AT devices.

  9. Early-Stage Software Design for Usability

    ERIC Educational Resources Information Center

    Golden, Elspeth

    2010-01-01

    In spite of the goodwill and best efforts of software engineers and usability professionals, systems continue to be built and released with glaring usability flaws that are costly and difficult to fix after the system has been built. Although user interface (UI) designers, be they usability or design experts, communicate usability requirements to…

  10. Investigation of the Usability of Computerized Critical Care Information Systems in Germany.

    PubMed

    von Dincklage, Falk; Suchodolski, Klaudiusz; Lichtner, Gregor; Friesdorf, Wolfgang; Podtschaske, Beatrice; Ragaller, Maximilian

    2017-01-01

    The term "usability" describes how effectively, efficiently, and with what level of user satisfaction an information system can be used to accomplish specific goals. Computerized critical care information systems (CCISs) with high usability increase quality of care and staff satisfaction, while reducing medication errors. Conversely, systems lacking usability can interrupt clinical workflow, facilitate errors, and increase charting time. The aim of this study was to investigate and compare usability across CCIS currently used in Germany. In this study, German intensive care unit (ICU) nurses and physicians completed a specialized, previously validated, web-based questionnaire. The questionnaire assessed CCIS usability based on three rating models: an overall rating of the systems, a model rating technical usability, and a model rating task-specific usability. We analyzed results from 535 survey participants and compared eight different CCIS commonly used in Germany. Our results showed that usability strongly differs across the compared systems. The system ICUData had the best overall rating and technical usability, followed by the platforms ICM and MetaVision. The same three systems performed best in the rating of task-specific usability without significant differences between each other. Across all systems, overall ratings were more dependent on ease-of-use aspects than on aspects of utility/functionality, and the general scope of the functions offered was rated better than how well the functions are realized. Our results suggest that manufacturers should shift some of their effort away from the development of new features and focus more on improving the ease-of-use and quality of existing features.

  11. Does the use of structured reporting improve usability? A comparative evaluation of the usability of two approaches for findings reporting in a large-scale telecardiology context.

    PubMed

    Lacerda, Thaisa Cardoso; von Wangenheim, Christiane Gresse; von Wangenheim, Aldo; Giuliano, Isabela

    2014-12-01

    One of the main reasons that leads to a low adoption rate of telemedicine systems is poor usability. An aspect that influences usability during the reporting of findings is the input mode, e.g., if a free-text (FT) or a structured report (SR) interface is employed. The objective of our study is to compare the usability of FT and ST telemedicine systems, specifically in terms of user satisfaction, efficiency and general usability. We comparatively evaluate the usability of these two input modes in a telecardiology system for issuing electrocardiography reports in the context of a statewide telemedicine system in Brazil with more than 350.000 performed tele-electrocardiography examinations. We adopted a multiple method research strategy, applying three different kinds of usability evaluations: user satisfaction was evaluated through interviews with seven medical professionals using the System Usability Scale (SUS) questionnaire and specific questions related to adequacy and user experience. Efficiency was evaluated by estimating execution time using the Keystroke-Level Model (KLM). General usability was assessed based on the conformity of the systems to a set of e-health specific usability heuristics. The results of this comparison provide a first indication that a structured report (SR) input mode for such a system is more satisfactory and efficient with a larger conformity to usability heuristics than free-text (FT) input. User satisfaction using the SUS questionnaire has been scored in average with 58.8 and 77.5 points for the FT and SR system, respectively, which means that the SR system was rated 18.65 points higher than the FT system. In terms of efficiency, the completion of a findings report using the SR mode is estimated to take 8.5s, 3.74 times faster than using the FT system (31.8s). The SR system also demonstrated less violations to usability heuristics (8 points) in comparison to 14 points observed in the FT system. These results provide a first indication that the usage of structured reporting as an input mode in telecardiology systems may enhance usability. This also seems to confirm the advantages of the usage of structured reporting, as already described in the literature for other areas such as teleradiology. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Combining usability evaluations to highlight the chain that leads from usability flaws to usage problems and then negative outcomes.

    PubMed

    Watbled, Ludivine; Marcilly, Romaric; Guerlinger, Sandra; Bastien, J-M Christian; Beuscart-Zéphir, Marie-Catherine; Beuscart, Régis

    2018-02-01

    Poor usability of health technology is thought to diminish work system performance, increase error rates and, potentially, harm patients. The present study (i) used a combination of usability evaluation methods to highlight the chain that leads from usability flaws to usage problems experienced by users and, ultimately, to negative patient outcomes, and (ii) validated this approach by studying two different discharge summary production systems. To comply with quality guidelines, the process of drafting and sending discharge summaries is increasingly being automated. However, the usability of these systems may modify their impact (or the absence thereof) in terms of production times and quality, and must therefore be evaluated. Here, we applied three successive techniques for usability evaluation (heuristic evaluation, user testing and field observation) to two discharge summary production systems (underpinned by different technologies). The systems' main usability flaws led respectively to an increase in the time need to produce a discharge summary and the risk of patient misidentification. Our results are discussed with regard to the possibility of linking the usability flaws, usage problems and the negative outcomes by successively applying three methods for evaluating usability (heuristic evaluation, user testing and in situ observations) throughout the system development life cycle. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. A usability evaluation of four commercial dental computer-based patient record systems

    PubMed Central

    Thyvalikakath, Thankam P.; Monaco, Valerie; Thambuganipalle, Hima Bindu; Schleyer, Titus

    2008-01-01

    Background The usability of dental computer-based patient record (CPR) systems has not been studied, despite early evidence that poor usability is a problem for dental CPR system users at multiple levels. Methods The authors conducted formal usability tests of four dental CPR systems by using a purposive sample of four groups of five novice users. The authors measured task outcomes (correctly completed, incorrectly completed and incomplete) in each CPR system while the participants performed nine clinical documentation tasks, as well as the number of usability problems identified in each CPR system and their potential relationship to task outcomes. The authors reviewed the software application design aspects responsible for these usability problems. Results The range for correctly completed tasks was 16 to 64 percent, for incorrectly completed tasks 18 to 38 percent and for incomplete tasks 9 to 47 percent. The authors identified 286 usability problems. The main types were three unsuccessful attempts, negative affect and task incorrectly completed. They also identified six problematic interface and interaction designs that led to usability problems. Conclusion The four dental CPR systems studied have significant usability problems for novice users, resulting in a steep learning curve and potentially reduced system adoption. Clinical Implications The significant number of data entry errors raises concerns about the quality of documentation in clinical practice. PMID:19047669

  14. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    PubMed

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  15. Qualitative review of usability problems in health information systems for radiology.

    PubMed

    Dias, Camila Rodrigues; Pereira, Marluce Rodrigues; Freire, André Pimenta

    2017-12-01

    Radiology processes are commonly supported by Radiology Information System (RIS), Picture Archiving and Communication System (PACS) and other software for radiology. However, these information technologies can present usability problems that affect the performance of radiologists and physicians, especially considering the complexity of the tasks involved. The purpose of this study was to extract, classify and analyze qualitatively the usability problems in PACS, RIS and other software for radiology. A systematic review was performed to extract usability problems reported in empirical usability studies in the literature. The usability problems were categorized as violations of Nielsen and Molich's usability heuristics. The qualitative analysis indicated the causes and the effects of the identified usability problems. From the 431 papers initially identified, 10 met the study criteria. The analysis of the papers identified 90 instances of usability problems, classified into categories corresponding to established usability heuristics. The five heuristics with the highest number of instances of usability problems were "Flexibility and efficiency of use", "Consistency and standards", "Match between system and the real world", "Recognition rather than recall" and "Help and documentation", respectively. These problems can make the interaction time consuming, causing delays in tasks, dissatisfaction, frustration, preventing users from enjoying all the benefits and functionalities of the system, as well as leading to more errors and difficulties in carrying out clinical analyses. Furthermore, the present paper showed a lack of studies performed on systems for radiology, especially usability evaluations using formal methods of evaluation involving the final users. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Usability Evaluation of Electronic Health Record System around Clinical Notes Usage-An Ethnographic Study.

    PubMed

    Rizvi, Rubina F; Marquard, Jenna L; Hultman, Gretchen M; Adam, Terrence J; Harder, Kathleen A; Melton, Genevieve B

    2017-10-01

    Background A substantial gap exists between current Electronic Health Record (EHR) usability and potential optimal usability. One of the fundamental reasons for this discrepancy is poor incorporation of a User-Centered Design (UCD) approach during the Graphical User Interface (GUI) development process. Objective To evaluate usability strengths and weaknesses of two widely implemented EHR GUIs for critical clinical notes usage tasks. Methods Twelve Internal Medicine resident physicians interacting with one of the two EHR systems (System-1 at Location-A and System-2 at Location-B) were observed by two usability evaluators employing an ethnographic approach. User comments and observer findings were analyzed for two critical tasks: (1) clinical notes entry and (2) related information-seeking tasks. Data were analyzed from two standpoints: (1) usability references categorized by usability evaluators as positive, negative, or equivocal and (2) usability impact of each feature measured through a 7-point severity rating scale. Findings were also validated by user responses to a post observation questionnaire. Results For clinical notes entry, System-1 surpassed System-2 with more positive (26% vs. 12%) than negative (12% vs. 34%) usability references. Greatest impact features on EHR usability (severity score pertaining to each feature) for clinical notes entry were: autopopulation (6), screen options (5.5), communication (5), copy pasting (4.5), error prevention (4.5), edit ability (4), and dictation and transcription (3.5). Both systems performed equally well on information-seeking tasks and features with greatest impacts on EHR usability were navigation for notes (7) and others (e.g., looking for ancillary data; 5.5). Ethnographic observations were supported by follow-up questionnaire responses. Conclusion This study provides usability-specific insights to inform future, improved, EHR interface that is better aligned with UCD approach.

  17. Innovative Telemonitoring System for Cardiology: From Science to Routine Operation

    PubMed Central

    Kastner, P.; Morak, J.; Modre, R.; Kollmann, A.; Ebner, C.; Fruhwald, FM.; Schreier, G.

    2010-01-01

    Objective Results of the Austrian MOBITEL (MOBIle phone based TELemonitoring for heart failure patients) trial indicate that home-based telemonitoring improves outcome of chronic heart failure (CHF) patients and reduces both frequency and duration of hospitalizations. Based on lessons learned, we assessed the weak points to clear the way for routine operations. Methods We analyzed the system with respect to recommendations of the ESC Guidelines and experiences gained throughout the trial to identify potential improvements. The following components have been identified: a patient terminal with highest usability, integrated way to document drug-intake and well-being, and automated event detection for worsening of CHF. As a consequence the system was extended by Near Field Communication (NFC) technology and by an event management tool. Results Usability evaluation with 30 adults (14f, median 51y. IQR[45-65]) showed that 21 (8f) were able to immediately operate the system after reading a step-by-step manual. Eight (6f) needed one time demonstration and one man (80y) failed to operate the blood pressure meter. Routine operation of the revised system started in March 2009. Within 9 months, 15 patients (4f, median 74y. IQR[71-83], all NYHA-III) transmitted 17,149 items. 43 events were detected because of body weight gain of more then 2kg within 2 days. 49 therapy adjustments were documented. Three patients stopped using the system, two (1f) because of non-compliance and one (m, 82y) because of death. Overall, the rate of adherence to daily data transfer was 78%. Conclusion First results confirm the applicability of the revised telemonitoring system in routine operation. PMID:23616835

  18. Usability Evaluation of a Web-Based Learning System

    ERIC Educational Resources Information Center

    Nguyen, Thao

    2012-01-01

    The paper proposes a contingent, learner-centred usability evaluation method and a prototype tool of such systems. This is a new usability evaluation method for web-based learning systems using a set of empirically-supported usability factors and can be done effectively with limited resources. During the evaluation process, the method allows for…

  19. Capacity and reliability analyses with applications to power quality

    NASA Astrophysics Data System (ADS)

    Azam, Mohammad; Tu, Fang; Shlapak, Yuri; Kirubarajan, Thiagalingam; Pattipati, Krishna R.; Karanam, Rajaiah

    2001-07-01

    The deregulation of energy markets, the ongoing advances in communication networks, the proliferation of intelligent metering and protective power devices, and the standardization of software/hardware interfaces are creating a dramatic shift in the way facilities acquire and utilize information about their power usage. The currently available power management systems gather a vast amount of information in the form of power usage, voltages, currents, and their time-dependent waveforms from a variety of devices (for example, circuit breakers, transformers, energy and power quality meters, protective relays, programmable logic controllers, motor control centers). What is lacking is an information processing and decision support infrastructure to harness this voluminous information into usable operational and management knowledge to handle the health of their equipment and power quality, minimize downtime and outages, and to optimize operations to improve productivity. This paper considers the problem of evaluating the capacity and reliability analyses of power systems with very high availability requirements (e.g., systems providing energy to data centers and communication networks with desired availability of up to 0.9999999). The real-time capacity and margin analysis helps operators to plan for additional loads and to schedule repair/replacement activities. The reliability analysis, based on computationally efficient sum of disjoint products, enables analysts to decide the optimum levels of redundancy, aids operators in prioritizing the maintenance options for a given budget and monitoring the system for capacity margin. The resulting analytical and software tool is demonstrated on a sample data center.

  20. Mobility Outcomes Following Five Training Sessions with a Powered Exoskeleton

    PubMed Central

    Hartigan, Clare; Kandilakis, Casey; Dalley, Skyler; Clausen, Mike; Wilson, Edgar; Morrison, Scott; Etheridge, Steven

    2015-01-01

    Background: Loss of legged mobility due to spinal cord injury (SCI) is associated with multiple physiological and psychological impacts. Powered exoskeletons offer the possibility of regained mobility and reversal or prevention of the secondary effects associated with immobility. Objective: This study was conducted to evaluate mobility outcomes for individuals with SCI after 5 gait-training sessions with a powered exoskeleton, with a primary goal of characterizing the ease of learning and usability of the system. Methods: Sixteen subjects with SCI were enrolled in a pilot clinical trial at Shepherd Center, Atlanta, Georgia, with injury levels ranging from C5 complete to L1 incomplete. An investigational Indego exoskeleton research kit was evaluated for ease of use and efficacy in providing legged mobility. Outcome measures of the study included the 10-meter walk test (10MWT) and the 6-minute walk test (6MWT) as well as measures of independence including donning and doffing times and the ability to walk on various surfaces. Results: At the end of 5 sessions (1.5 hours per session), average walking speed was 0.22 m/s for persons with C5-6 motor complete tetraplegia, 0.26 m/s for T1-8 motor complete paraplegia, and 0.45 m/s for T9-L1 paraplegia. Distances covered in 6 minutes averaged 64 meters for those with C5-6, 74 meters for T1-8, and 121 meters for T9-L1. Additionally, all participants were able to walk on both indoor and outdoor surfaces. Conclusions: Results after only 5 sessions suggest that persons with tetraplegia and paraplegia learn to use the Indego exoskeleton quickly and can manage a variety of surfaces. Walking speeds and distances achieved also indicate that some individuals with paraplegia can quickly become limited community ambulators using this system. PMID:26364278

  1. Translation, Cross-Cultural Adaptation, and Validation of the Malay Version of the System Usability Scale Questionnaire for the Assessment of Mobile Apps.

    PubMed

    Mohamad Marzuki, Muhamad Fadhil; Yaacob, Nor Azwany; Yaacob, Najib Majdi

    2018-05-14

    A mobile app is a programmed system designed to be used by a target user on a mobile device. The usability of such a system refers not only to the extent to which product can be used to achieve the task that it was designed for, but also its effectiveness and efficiency, as well as user satisfaction. The System Usability Scale is one of the most commonly used questionnaires used to assess the usability of a system. The original 10-item version of System Usability Scale was developed in English and thus needs to be adapted into local languages to assess the usability of a mobile apps developed in other languages. The aim of this study is to translate and validate (with cross-cultural adaptation) the English System Usability Scale questionnaire into Malay, the main language spoken in Malaysia. The development of a translated version will allow the usability of mobile apps to be assessed in Malay. Forward and backward translation of the questionnaire was conducted by groups of Malay native speakers who spoke English as their second language. The final version was obtained after reconciliation and cross-cultural adaptation. The content of the Malay System Usability Scale questionnaire for mobile apps was validated by 10 experts in mobile app development. The efficacy of the questionnaire was further probed by testing the face validity on 10 mobile phone users, followed by reliability testing involving 54 mobile phone users. The content validity index was determined to be 0.91, indicating good relevancy of the 10 items used to assess the usability of a mobile app. Calculation of the face validity index resulted in a value of 0.94, therefore indicating that the questionnaire was easily understood by the users. Reliability testing showed a Cronbach alpha value of .85 (95% CI 0.79-0.91) indicating that the translated System Usability Scale questionnaire is a reliable tool for the assessment of usability of a mobile app. The Malay System Usability Scale questionnaire is a valid and reliable tool to assess the usability of mobile app in Malaysia. ©Muhamad Fadhil Mohamad Marzuki, Nor Azwany Yaacob, Najib Majdi Yaacob. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 14.05.2018.

  2. End-Users' Voice in EHR Selection: Development of a Usability Questionnaire for Demonstrations in Procurement (DPUQ).

    PubMed

    Tyllinen, Mari; Kaipio, Johanna; Lääveri, Tinja; Nieminen, Marko

    2017-01-01

    This paper describes the development of a questionnaire for evaluating usability during EHR system procurement (DPUQ). Established usability questionnaires can be used to gather user feedback after using the systems. However, during procurement, experimenting with real system use is practical only with a limited number of system candidates. There is a need for less resource-demanding usability evaluation in the early stages of procurement in cases with several vendors. DPUQ has been designed for usability evaluation by end-users during special scenario-based vendor demonstrations. The questionnaire includes three sets of questions to be used during and after the vendor demonstration. DPUQ delivers specific usability scores and can be used to compare system candidates in procurement complementing other evaluation methods.

  3. Development of a Video Coding Scheme for Analyzing the Usability and Usefulness of Health Information Systems.

    PubMed

    Kushniruk, Andre W; Borycki, Elizabeth M

    2015-01-01

    Usability has been identified as a key issue in health informatics. Worldwide numerous projects have been carried out in an attempt to increase and optimize health system usability. Usability testing, involving observing end users interacting with systems, has been widely applied and numerous publications have appeared describing such studies. However, to date, fewer works have been published describing methodological approaches to analyzing the rich data stream that results from usability testing. This includes analysis of video, audio and screen recordings. In this paper we describe our work in the development and application of a coding scheme for analyzing the usability of health information systems. The phases involved in such analyses are described.

  4. National questionnaire study on clinical ICT systems proofs: physicians suffer from poor usability.

    PubMed

    Viitanen, Johanna; Hyppönen, Hannele; Lääveri, Tinja; Vänskä, Jukka; Reponen, Jarmo; Winblad, Ilkka

    2011-10-01

    In the health informatics field, usability studies typically focus on evaluating a single information system and involve a rather small group of end-users. However, little is known about the usability of clinical information and communication technology (ICT) environment in which healthcare professionals work daily. This paper aims at contributing to usability research and user-oriented development of healthcare technologies with three objectives: inform researchers and practitioners about the current state of usability of clinical ICT systems, increase the understanding of usability aspects specific for clinical context, and encourage a more holistic approach on studying usability issues in health informatics field. A national web questionnaire study was conducted in Finland in spring 2010 with 3929 physicians actively working in patient care. For the purposes of the study, we described three dimensions of clinical ICT system usability that reflect the physicians' viewpoint on system usage: (1) compatibility between clinical ICT systems and physicians' tasks, (2) ICT support for information exchange, communication and collaboration in clinical work, and (3) interoperability and reliability. The dimensions derive from the definitions of usability and clinical context of use analysis, and reflect the ability of ICT systems to have a positive impact on patient care by supporting physicians in achieving their goals with a pleasant user experience. The research data incorporated 32 statements with a five-point Likert-scale on physicians' experiences on usability of their currently used ICT systems and a summative question about school grade given to electronic health record (EHR) systems. Physicians' estimates of their EHR systems were very critical. With the rating scale from 4 or fail to 10 or excellent, the average of the grades varied from 6.1 to 8.4 dependent on the kind of facility the physician is working. Questionnaire results indicated several usability problems and deficiencies which considerably hindered the efficiency of clinical ICT use and physician's routine work. Systems lacked the appropriate features to support typical clinical tasks, such as decision making, prevention of medical errors, and review of a patient's treatment chart. The systems also required physicians to perform fixed sequences of steps and tasks, and poorly supported the documentation and retrieval of patient data. The findings on ICT support for collaboration showed mainly negative results, aside from collaboration between co-located physicians. In addition, the study results pointed out physicians suffering from system failures and a lack of integration between the systems. The described study and related results are unique in several ways. A national usability study with nearly 4000 respondents had not been conducted in other countries in which healthcare technologies are widely adopted. The questionnaire study provided a generalized picture about the usability problems, however, it should be noted that there were significant differences between legacy systems in use. Previously, researchers had not approached contextual aspects of usability the context of clinical work, where numerous systems are in use. The described usability dimensions and the presented study results can be considered as the first step towards conceptualizing ICT usability in the unique setting of clinical work. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. 76 FR 8715 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    .... Title; Associated Form; and OMB Number: Electronic Health Record (EHR) Usability Survey; OMB Control... longitudinal measure of how end-users perceive the usability of the Department of Defense (DoD) suite of... usability of a system. This usability attribute describes the ease with which people can use the system to...

  6. Beyond Effectiveness: A Pragmatic Evaluation Framework for Learning and Continuous Quality Improvement of e-Learning Interventions in Healthcare.

    PubMed

    Dafalla, Tarig Dafalla Mohamed; Kushniruk, Andre W; Borycki, Elizabeth M

    2015-01-01

    A pragmatic evaluation framework for evaluating the usability and usefulness of an e-learning intervention for a patient clinical information scheduling system is presented in this paper. The framework was conceptualized based on two different but related concepts (usability and usefulness) and selection of appropriate and valid methods of data collection and analysis that included: (1) Low-Cost Rapid Usability Engineering (LCRUE), (2) Cognitive Task Analysis (CTA), (3) Heuristic Evaluation (HE) criteria for web-based learning, and (4) Software Usability Measurement Inventory (SUMI). The results of the analysis showed some areas where usability that were related to General Interface Usability (GIU), instructional design and content was problematic; some of which might account for the poorly rated aspects of usability when subjectively measured. This paper shows that using a pragmatic framework can be a useful way, not only for measuring the usability and usefulness, but also for providing a practical objective evidences for learning and continuous quality improvement of e-learning systems. The findings should be of interest to educators, developers, designers, researchers, and usability practitioners involved in the development of e-learning systems in healthcare. This framework could be an appropriate method for assessing the usability, usefulness and safety of health information systems both in the laboratory and in the clinical context.

  7. Interactivity Centered Usability Evaluation (ICUE) for Course Management Systems

    ERIC Educational Resources Information Center

    Yoon, Sangil

    2010-01-01

    ICUE (Interactivity Centered Usability Evaluation) is an enhanced usability testing protocol created by the researcher. ICUE augments the facilitator's role for usability testing, and offers strategies in developing and presenting usability tasks during a testing session. ICUE was designed to address weaknesses found in the usability evaluation of…

  8. Comparison of two heuristic evaluation methods for evaluating the usability of health information systems.

    PubMed

    Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh

    2018-04-01

    In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p < 0.0001). After removing the duplicates, the difference between the number of unique usability problems identified by the checklist method (n = 100) and usual method (n = 44) was significant (p < 0.0001). Differences between the mean severity of the real usability problems (1.83) and those identified by only one of the methods (usual = 2.05, checklist = 1.74) were significant (p = 0.001). This study revealed the potential of the two HE methods for identifying usability problems of health information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Usability evaluation of the interactive Personal Patient Profile-Prostate decision support system with African American men.

    PubMed

    Jaja, Cheedy; Pares-Avila, Jose; Wolpin, Seth; Berry, Donna

    2010-04-01

    The Personal Patient Profile-Prostate (P4) program is an interactive Web-based decision support system that provides men with localized prostate cancer customized education and coaching with which to make the best personal treatment decision. This study assessed functionality and usability of the P4 program and identified problems in user-computer interaction in a sample of African American men. Usability testing was conducted with 12 community-dwelling African American adult men. The health status of participants was not known or collected by the research team. Each participant worked with the P4 program and provided simultaneous feedback using the "think aloud" technique. Handwritten field notes were collated and assigned to 3 standard coded categories. Aspects of P4 program usability was made based on common issues in the assigned categories. Summary statistics were derived for types and frequency of usability issues noted in the coded data. Twelve participants reported a total of 122 usability comments, with a mean of 9 usability comments. The most common usability issue by participant was completeness of information content, which comprised 53 (43%) of the total issues. Comprehensibility of text and graphics was second, comprising 51 (42%) of the total issues. This study provided initial inventory of usability issues for community African American men that may potentially interfere with application of the P4 system in the community setting and overall system usability, confirming the need for usability testing of a culturally appropriate Internet-based decision support system before community application.

  10. How Do Clinical Information Systems Affect the Cognitive Demands of General Practitioners?: Usability Study with a Focus on Cognitive Workload.

    PubMed

    Ariza, Ferran; Kalra, Dipak; Potts, Henry Ww

    2015-11-20

    Clinical information systems in the National Health Service do not need to conform to any explicit usability requirements. Poor usability can increase the mental workload experienced by clinicians and cause fatigue, increase error rates and impact the overall patient safety. Mental workload can be used as a measure of usability. To assess the subjective cognitive workload experienced by general practitioners (GPs) with their systems. To raise awareness of the importance of usability in system design among users, designers, developers and policymakers. We used a modified version of the NASA Task Load Index, adapted for web. We developed a set of common clinical scenarios and computer tasks on an online survey. We emailed the study link to 199 clinical commissioning groups and 1,646 GP practices in England. Sixty-seven responders completed the survey. The respondents had spent an average of 17 years in general practice, had experience of using a mean of 1.5 GP computer systems and had used their current system for a mean time of 6.7 years. The mental workload score was not different among systems. There were significant differences among the task scores, but these differences were not specific to particular systems. The overall score and task scores were related to the length of experience with their present system. Four tasks imposed a higher mental workload on GPs: 'repeat prescribing', 'find episode', 'drug management' and 'overview records'. Further usability studies on GP systems should focus on these tasks. Users, policymakers, designers and developers should remain aware of the importance of usability in system design.What does this study add?• Current GP systems in England do not need to conform to explicit usability requirements. Poor usability can increase the mental workload of clinicians and lead to errors.• Some clinical computer tasks incur more cognitive workload than others and should be considered carefully during the design of a system.• GPs did not report overall very high levels of subjective cognitive workload when undertaking common clinical tasks with their systems.• Further usability studies on GP systems should focus on the tasks incurring higher cognitive workload.• Users, policymakers, and designers and developers should remain aware of the importance of usability in system design.

  11. Debunking Health IT Usability Myths

    PubMed Central

    Staggers, N.; Xiao, Y.; Chapman, L.

    2013-01-01

    Poor usability is a threat to patient safety and linked to productivity loss, workflow disruption, user frustration, sub-optimal product use and system de-installations. Although usability is receiving more attention nationally and internationally, myths about usability persist. This editorial debunks five common myths about usability (1) usability only concerns the look and feel of a product and is, therefore, only a minor concern, (2) usability is not measurable, (3) usability stifles innovation, (4) vendors are solely responsible for product usability, and (5) usability methods are not practical for use in healthcare. PMID:23874361

  12. Pre-post evaluation of physicians' satisfaction with a redesigned electronic medical record system.

    PubMed

    Jaspers, Monique W M; Peute, Linda W P; Lauteslager, Arnaud; Bakker, Piet J M

    2008-01-01

    Physicians' acceptance of Electronic Medical Record Systems (EMRs) is closely related to their usability. Knowledge about end-users' opinions on usability of an EMR system may contribute to planning for the next phase of the usability cycle of the system. A demand for integration of new functionalities, such as computerized order entry and an electronic patient status led to redesign of our EMR system, which had been in use for over 8 years at the Academic Medical Center of Amsterdam. The aim of this study was to understand whether the redesigned EMR system was an improvement of the earlier EMR and which system aspects accounted for user satisfaction and which did not. We conducted a formative pre- and post usability evaluation of our former and redesigned EMR system. For the assessment of both system versions' usability, we distributed two standardized usability questionnaires among 150 clinicians who routinely had used the older EMR system and had been working with its newer version for 6 weeks. Though overall user satisfaction was relatively high for both EMR systems, screen layout and interaction structure proved less easy to work with in the newer EMR system. The new EMR system however was more appreciated because of its enhanced functionality, capabilities and likeable user-interface. The results point to a number of actions that might be useful in future usability improvement efforts of our EMR system and other EMRs.

  13. TopoLens: Building a cyberGIS community data service for enhancing the usability of high-resolution National Topographic datasets

    USGS Publications Warehouse

    Hu, Hao; Hong, Xingchen; Terstriep, Jeff; Liu, Yan; Finn, Michael P.; Rush, Johnathan; Wendel, Jeffrey; Wang, Shaowen

    2016-01-01

    Geospatial data, often embedded with geographic references, are important to many application and science domains, and represent a major type of big data. The increased volume and diversity of geospatial data have caused serious usability issues for researchers in various scientific domains, which call for innovative cyberGIS solutions. To address these issues, this paper describes a cyberGIS community data service framework to facilitate geospatial big data access, processing, and sharing based on a hybrid supercomputer architecture. Through the collaboration between the CyberGIS Center at the University of Illinois at Urbana-Champaign (UIUC) and the U.S. Geological Survey (USGS), a community data service for accessing, customizing, and sharing digital elevation model (DEM) and its derived datasets from the 10-meter national elevation dataset, namely TopoLens, is created to demonstrate the workflow integration of geospatial big data sources, computation, analysis needed for customizing the original dataset for end user needs, and a friendly online user environment. TopoLens provides online access to precomputed and on-demand computed high-resolution elevation data by exploiting the ROGER supercomputer. The usability of this prototype service has been acknowledged in community evaluation.

  14. Design and validation of a questionnaire to evaluate the usability of computerized critical care information systems.

    PubMed

    von Dincklage, Falk; Lichtner, Gregor; Suchodolski, Klaudiusz; Ragaller, Maximilian; Friesdorf, Wolfgang; Podtschaske, Beatrice

    2017-08-01

    The implementation of computerized critical care information systems (CCIS) can improve the quality of clinical care and staff satisfaction, but also holds risks of disrupting the workflow with consecutive negative impacts. The usability of CCIS is one of the key factors determining their benefits and weaknesses. However, no tailored instrument exists to measure the usability of such systems. Therefore, the aim of this study was to design and validate a questionnaire that measures the usability of CCIS. Following a mixed-method design approach, we developed a questionnaire comprising two evaluation models to assess the usability of CCIS: (1) the task-specific model rates the usability individually for several tasks which CCIS could support and which we derived by analyzing work processes in the ICU; (2) the characteristic-specific model rates the different aspects of the usability, as defined by the international standard "ergonomics of human-system interaction". We tested validity and reliability of the digital version of the questionnaire in a sample population. In the sample population of 535 participants both usability evaluation models showed a strong correlation with the overall rating of the system (multiple correlation coefficients ≥0.80) as well as a very high internal consistency (Cronbach's alpha ≥0.93). The novel questionnaire is a valid and reliable instrument to measure the usability of CCIS and can be used to study the influence of the usability on their implementation benefits and weaknesses.

  15. Re-usable electrochemical glucose sensors integrated into a smartphone platform.

    PubMed

    Bandodkar, Amay J; Imani, Somayeh; Nuñez-Flores, Rogelio; Kumar, Rajan; Wang, Chiyi; Mohan, A M Vinu; Wang, Joseph; Mercier, Patrick P

    2018-03-15

    This article demonstrates a new smartphone-based reusable glucose meter. The glucose meter includes a custom-built smartphone case that houses a permanent bare sensor strip, a stylus that is loaded with enzyme-carbon composite pellets, and sensor instrumentation circuits. A custom-designed Android-based software application was developed to enable easy and clear display of measured glucose concentration. A typical test involves the user loading the software, using the stylus to dispense an enzymatic pellet on top of the bare sensor strip affixed to the case, and then introducing the sample. The electronic module then acquires and wirelessly transmits the data to the application software to be displayed on the screen. The deployed pellet is then discarded to regain the fresh bare sensor surface. Such a unique working principle allows the system to overcome challenges faced by previously reported reusable sensors, such as enzyme degradation, leaching, and hysteresis effects. Studies reveal that the enzyme loaded in the pellets are stable for up to 8 months at ambient conditions, and generate reproducible sensor signals. The work illustrates the significance of the pellet-based sensing system towards realizing a reusable, point-of-care sensor that snugly fits around a smartphone and which does not face issues usually common to reusable sensors. The versatility of this system allows it to be easily modified to detect other analytes for application in a wide range of healthcare, environmental and defense domains. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Usability engineering: domain analysis activities for augmented-reality systems

    NASA Astrophysics Data System (ADS)

    Gabbard, Joseph; Swan, J. E., II; Hix, Deborah; Lanzagorta, Marco O.; Livingston, Mark; Brown, Dennis B.; Julier, Simon J.

    2002-05-01

    This paper discusses our usability engineering process for the Battlefield Augmented Reality System (BARS). Usability engineering is a structured, iterative, stepwise development process. Like the related disciplines of software and systems engineering, usability engineering is a combination of management principals and techniques, formal and semi- formal evaluation techniques, and computerized tools. BARS is an outdoor augmented reality system that displays heads- up battlefield intelligence information to a dismounted warrior. The paper discusses our general usability engineering process. We originally developed the process in the context of virtual reality applications, but in this work we are adapting the procedures to an augmented reality system. The focus of this paper is our work on domain analysis, the first activity of the usability engineering process. We describe our plans for and our progress to date on our domain analysis for BARS. We give results in terms of a specific urban battlefield use case we have designed.

  17. Usability Evaluation of Laboratory Information Systems.

    PubMed

    Mathews, Althea; Marc, David

    2017-01-01

    Numerous studies have revealed widespread clinician frustration with the usability of electronic health records (EHRs) that is counterproductive to adoption of EHR systems to meet the aims of health-care reform. With poor system usability comes increased risk of negative unintended consequences. Usability issues could lead to user error and workarounds that have the potential to compromise patient safety and negatively impact the quality of care.[1] While there is ample research on EHR usability, there is little information on the usability of laboratory information systems (LISs). Yet, LISs facilitate the timely provision of a great deal of the information needed by physicians to make patient care decisions.[2] Medical and technical advances in genomics that require processing of an increased volume of complex laboratory data further underscore the importance of developing user-friendly LISs. This study aims to add to the body of knowledge on LIS usability. A survey was distributed among LIS users at hospitals across the United States. The survey consisted of the ten-item System Usability Scale (SUS). In addition, participants were asked to rate the ease of performing 24 common tasks with a LIS. Finally, respondents provided comments on what they liked and disliked about using the LIS to provide diagnostic insight into LIS perceived usability. The overall mean SUS score of 59.7 for the LIS evaluated is significantly lower than the benchmark of 68 ( P < 0.001). All LISs evaluated received mean SUS scores below 68 except for Orchard Harvest (78.7). While the years of experience using the LIS was found to be a statistically significant influence on mean SUS scores, the combined effect of years of experience and LIS used did not account for the statistically significant difference in the mean SUS score between Orchard Harvest and each of the other LISs evaluated. The results of this study indicate that overall usability of LISs is poor. Usability lags that of systems evaluated across 446 usability surveys.

  18. Comparison of two kinds of interface, based on guided navigation or usability principles, for improving the adoption of computerized decision support systems: application to the prescription of antibiotics.

    PubMed

    Tsopra, Rosy; Jais, Jean-Philippe; Venot, Alain; Duclos, Catherine

    2014-02-01

    It is important to consider the way in which information is presented by the interfaces of clinical decision support systems, to favor the adoption of these systems by physicians. Interface design can focus on decision processes (guided navigation) or usability principles. The aim of this study was to compare these two approaches in terms of perceived usability, accuracy rate, and confidence in the system. We displayed clinical practice guidelines for antibiotic treatment via two types of interface, which we compared in a crossover design. General practitioners were asked to provide responses for 10 clinical cases and the System Usability Scale (SUS) for each interface. We assessed SUS scores, the number of correct responses, and the confidence level for each interface. SUS score and percentage confidence were significantly higher for the interface designed according to usability principles (81 vs 51, p=0.00004, and 88.8% vs 80.7%, p=0.004). The percentage of correct responses was similar for the two interfaces. The interface designed according to usability principles was perceived to be more usable and inspired greater confidence among physicians than the guided navigation interface. Consideration of usability principles in the construction of an interface--in particular 'effective information presentation', 'consistency', 'efficient interactions', 'effective use of language', and 'minimizing cognitive load'--seemed to improve perceived usability and confidence in the system.

  19. User perspectives on the usability of a regional health information exchange

    PubMed Central

    Ho, Yun-Xian; Cala, Cather Marie; Blakemore, Dana; Chen, Qingxia; Frisse, Mark E; Johnson, Kevin B

    2011-01-01

    Objective We assessed the usability of a health information exchange (HIE) in a densely populated metropolitan region. This grant-funded HIE had been deployed rapidly to address the imminent needs of the patient population and the need to draw wider participation from regional entities. Design We conducted a cross-sectional survey of individuals given access to the HIE at participating organizations and examined some of the usability and usage factors related to the technology acceptance model. Measurements We probed user perceptions using the Questionnaire for User Interaction Satisfaction, an author-generated Trust scale, and user characteristic questions (eg, age, weekly system usage time). Results Overall, users viewed the system favorably (ratings for all usability items were greater than neutral (one-sample Wilcoxon test, p<0.0014, Bonferroni-corrected for 35 tests). System usage was regressed on usability, trust, and demographic and user characteristic factors. Three usability factors were positively predictive of system usage: overall reactions (p<0 0.01), learning (p<0.05), and system functionality (p<0.01). Although trust is an important component in collaborative relationships, we did not find that user trust of other participating healthcare entities was significantly predictive of usage. An analysis of respondents' comments revealed ways to improve the HIE. Conclusion We used a rapid deployment model to develop an HIE and found that perceptions of system usability were positive. We also found that system usage was predicted well by some aspects of usability. Results from this study suggest that a rapid development approach may serve as a viable model for developing usable HIEs serving communities with limited resources. PMID:21622933

  20. How you spend your pennies ... factors affecting the efficiency of human waste disposal systems (re-usable and disposable) and their cost.

    PubMed

    Rollnick, M

    1991-05-01

    Both re-usable and disposable systems have their merits and problems. The disposable system, being fully integrated, appears to be steadily gaining market share compared with the re-usable system. Since its introduction, the success of the re-usable system has been limited by the use of pans not designed for automatic processing. Where the 'perfection' pan has been superseded by 'open' shaped receptacles and those used in commode chairs, cleaning effectiveness can be improved by a factor of 10. For this and other reasons, nursing involvement in the re-usable system can be high while the 'perfection' pan is in use. A work study exercise to compare nursing involvement in re-usable and disposable systems is under way. When selecting a human waste disposal system for any site, it is vital that all disciplines discuss and decide objectives. The equipment usage, space, site conditions, availability and quality of supplies (eg water, electricity), the costs of maintenance, nursing time and other expenditure must be considered. The disposable system is capable of high process rates (more than double that of the fastest re-usable system). Its capital cost is currently about 1,000 pounds less than an average re-usable system, but in the busiest wards, revenue costs may be higher. In such wards the space for disposable receptacle storage can be as much as five to ten times machine volume. The design of macerators is generally simpler (having less components) than washer-disinfectors. Monitoring and maintenance involvement are likewise expected to be lower, particularly in hospitals with modern drainage systems.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Usability of Low-Cost Android Data Collection System for Community-Based Participatory Research.

    PubMed

    Salihu, Hamisu M; Salinas-Miranda, Abraham; Turner, DeAnne; King, Lindsey; Paothong, Arnut; Austin, Deborah; Berry, Estrellita Lo

    2016-01-01

    Android tablet computers can be valuable tools for data collection, but their usability has not been evaluated in community-based participatory research (CBPR). This article examines the usability of a low-cost bilingual touchscreen computerized survey system using Android tablets, piloted with a sample of 201 community residents in Tampa, Florida, from November 2013 to March 2014. Needs assessment questions were designed with the droidSURVEY software, and deployed using Android tablet computers. In addition, participants were asked questions about system usability. The mean system usability was 77.57 ± 17.66 (range, 0-100). The mean completion time for taking the 63 survey questions in the needs assessment was 23.11 ± 9.62 minutes. The survey completion rate was optimal (100%), with only 6.34% missingness per variable. We found no sociodemographic differences in usability scores. Our findings indicate that Android tablets could serve as useful tools in CBPR studies.

  2. An Iterative, Mixed Usability Approach Applied to the Telekit System from the Danish TeleCare North Trial

    PubMed Central

    Schaarup, Clara; Hejlesen, Ole Kristian

    2016-01-01

    Objective. The aim of the present study is to evaluate the usability of the telehealth system, coined Telekit, by using an iterative, mixed usability approach. Materials and Methods. Ten double experts participated in two heuristic evaluations (HE1, HE2), and 11 COPD patients attended two think-aloud tests. The double experts identified usability violations and classified them into Jakob Nielsen's heuristics. These violations were then translated into measurable values on a scale of 0 to 4 indicating degree of severity. In the think-aloud tests, COPD participants were invited to verbalise their thoughts. Results. The double experts identified 86 usability violations in HE1 and 101 usability violations in HE2. The majority of the violations were rated in the 0–2 range. The findings from the think-aloud tests resulted in 12 themes and associated examples regarding the usability of the Telekit system. The use of the iterative, mixed usability approach produced both quantitative and qualitative results. Conclusion. The iterative, mixed usability approach yields a strong result owing to the high number of problems identified in the tests because the double experts and the COPD participants focus on different aspects of Telekit's usability. This trial is registered with Clinicaltrials.gov, NCT01984840, November 14, 2013. PMID:27974888

  3. An Iterative, Mixed Usability Approach Applied to the Telekit System from the Danish TeleCare North Trial.

    PubMed

    Lilholt, Pernille Heyckendorff; Schaarup, Clara; Hejlesen, Ole Kristian

    2016-01-01

    Objective . The aim of the present study is to evaluate the usability of the telehealth system, coined Telekit, by using an iterative, mixed usability approach. Materials and Methods . Ten double experts participated in two heuristic evaluations (HE1, HE2), and 11 COPD patients attended two think-aloud tests. The double experts identified usability violations and classified them into Jakob Nielsen's heuristics. These violations were then translated into measurable values on a scale of 0 to 4 indicating degree of severity. In the think-aloud tests, COPD participants were invited to verbalise their thoughts. Results . The double experts identified 86 usability violations in HE1 and 101 usability violations in HE2. The majority of the violations were rated in the 0-2 range. The findings from the think-aloud tests resulted in 12 themes and associated examples regarding the usability of the Telekit system. The use of the iterative, mixed usability approach produced both quantitative and qualitative results. Conclusion . The iterative, mixed usability approach yields a strong result owing to the high number of problems identified in the tests because the double experts and the COPD participants focus on different aspects of Telekit's usability. This trial is registered with Clinicaltrials.gov, NCT01984840, November 14, 2013.

  4. The Cultural Evolution of Human Communication Systems in Different Sized Populations: Usability Trumps Learnability

    PubMed Central

    Fay, Nicolas; Ellison, T. Mark

    2013-01-01

    This study examines the intergenerational transfer of human communication systems. It tests if human communication systems evolve to be easy to learn or easy to use (or both), and how population size affects learnability and usability. Using an experimental-semiotic task, we find that human communication systems evolve to be easier to use (production efficiency and reproduction fidelity), but harder to learn (identification accuracy) for a second generation of naïve participants. Thus, usability trumps learnability. In addition, the communication systems that evolve in larger populations exhibit distinct advantages over those that evolve in smaller populations: the learnability loss (from the Initial signs) is more muted and the usability benefits are more pronounced. The usability benefits for human communication systems that evolve in a small and large population is explained through guided variation reducing sign complexity. The enhanced performance of the communication systems that evolve in larger populations is explained by the operation of a content bias acting on the larger pool of competing signs. The content bias selects for information-efficient iconic signs that aid learnability and enhance usability. PMID:23967243

  5. The cultural evolution of human communication systems in different sized populations: usability trumps learnability.

    PubMed

    Fay, Nicolas; Ellison, T Mark

    2013-01-01

    This study examines the intergenerational transfer of human communication systems. It tests if human communication systems evolve to be easy to learn or easy to use (or both), and how population size affects learnability and usability. Using an experimental-semiotic task, we find that human communication systems evolve to be easier to use (production efficiency and reproduction fidelity), but harder to learn (identification accuracy) for a second generation of naïve participants. Thus, usability trumps learnability. In addition, the communication systems that evolve in larger populations exhibit distinct advantages over those that evolve in smaller populations: the learnability loss (from the Initial signs) is more muted and the usability benefits are more pronounced. The usability benefits for human communication systems that evolve in a small and large population is explained through guided variation reducing sign complexity. The enhanced performance of the communication systems that evolve in larger populations is explained by the operation of a content bias acting on the larger pool of competing signs. The content bias selects for information-efficient iconic signs that aid learnability and enhance usability.

  6. Comparison of two kinds of interface, based on guided navigation or usability principles, for improving the adoption of computerized decision support systems: application to the prescription of antibiotics

    PubMed Central

    Tsopra, Rosy; Jais, Jean-Philippe; Venot, Alain; Duclos, Catherine

    2014-01-01

    Context It is important to consider the way in which information is presented by the interfaces of clinical decision support systems, to favor the adoption of these systems by physicians. Interface design can focus on decision processes (guided navigation) or usability principles. Objective The aim of this study was to compare these two approaches in terms of perceived usability, accuracy rate, and confidence in the system. Materials and methods We displayed clinical practice guidelines for antibiotic treatment via two types of interface, which we compared in a crossover design. General practitioners were asked to provide responses for 10 clinical cases and the System Usability Scale (SUS) for each interface. We assessed SUS scores, the number of correct responses, and the confidence level for each interface. Results SUS score and percentage confidence were significantly higher for the interface designed according to usability principles (81 vs 51, p=0.00004, and 88.8% vs 80.7%, p=0.004). The percentage of correct responses was similar for the two interfaces. Discussion/conclusion The interface designed according to usability principles was perceived to be more usable and inspired greater confidence among physicians than the guided navigation interface. Consideration of usability principles in the construction of an interface—in particular ‘effective information presentation’, ‘consistency’, ‘efficient interactions’, ‘effective use of language’, and ‘minimizing cognitive load’—seemed to improve perceived usability and confidence in the system. PMID:24008427

  7. Usability in the real world: assessing medical information technologies in patients' homes.

    PubMed

    Kaufman, David R; Patel, Vimla L; Hilliman, Charlyn; Morin, Philip C; Pevzner, Jenia; Weinstock, Ruth S; Goland, Robin; Shea, Steven; Starren, Justin

    2003-01-01

    This paper presents an approach to usability evaluation of computer-based health care systems designed for patient use in their homes. Although such devices are becoming more prevalent, there is very little known about their usability. The theoretical foundations for the methods are discussed. The approach incorporates a cognitive walkthrough usability evaluation and new methods for usability testing that can be conducted in patient's homes. The method was applied to the IDEATel intervention, a multi-institution randomized controlled trial of the feasibility, acceptability, and clinical utility of a home-based telemedicine system for diabetic Medicare population. The usability study was designed to assess barriers to optimal use of the system. The focus was both on dimensions of the interface and on dimensions of patient skills and competency. The usability field research involved testing 25 patients in their homes using the system. The analysis included a range of video-analytic methods of varying levels of granularity. The usability evaluation revealed aspects of the interface that were sub-optimal and impeded the performance of certain tasks. It also found a range of patient-related factors such as numeracy and psychomotor skills that constituted barriers to productive use. A multifaceted usability approach provided important insight regarding use of technology by an elderly chronic-care patient population and more generally, for understanding how home health initiatives can more effectively use such technology.

  8. The Relationship between National Culture and the Usability of an E-Learning System

    ERIC Educational Resources Information Center

    Downey, Steve; Wentling, Rose Mary; Wentling, Tim; Wadsworth, Andrew

    2004-01-01

    This study sought to measure the relationship between national culture and the usability of an e-Learning system by using Hofstede's cultural dimensions and Nielson's usability attributes. The study revealed that high uncertainty avoidance cultures found the system more frustrating to use. The study also revealed that individuals from cultures…

  9. A literature review about usability evaluation methods for e-learning platforms.

    PubMed

    Freire, Luciana Lopes; Arezes, Pedro Miguel; Campos, José Creissac

    2012-01-01

    The usability analysis of information systems has been the target of several research studies over the past thirty years. These studies have highlighted a great diversity of points of view, including researchers from different scientific areas such as Ergonomics, Computer Science, Design and Education. Within the domain of information ergonomics, the study of tools and methods used for usability evaluation dedicated to E-learning presents evidence that there is a continuous and dynamic evolution of E-learning systems, in many different contexts -academics and corporative. These systems, also known as LMS (Learning Management Systems), can be classified according to their educational goals and their technological features. However, in these systems the usability issues are related with the relationship/interactions between user and system in the user's context. This review is a synthesis of research project about Information Ergonomics and embraces three dimensions, namely the methods, models and frameworks that have been applied to evaluate LMS. The study also includes the main usability criteria and heuristics used. The obtained results show a notorious change in the paradigms of usability, with which it will be possible to discuss about the studies carried out by different researchers that were focused on usability ergonomic principles aimed at E-learning.

  10. A usability evaluation of a SNOMED CT based compositional interface terminology for intensive care.

    PubMed

    Bakhshi-Raiez, F; de Keizer, N F; Cornet, R; Dorrepaal, M; Dongelmans, D; Jaspers, M W M

    2012-05-01

    To evaluate the usability of a large compositional interface terminology based on SNOMED CT and the terminology application for registration of the reasons for intensive care admission in a Patient Data Management System. Observational study with user-based usability evaluations before and 3 months after the system was implemented and routinely used. Usability was defined by five aspects: effectiveness, efficiency, learnability, overall user satisfaction, and experienced usability problems. Qualitative (the Think-Aloud user testing method) and quantitative (the System Usability Scale questionnaire and Time-on-Task analyses) methods were used to examine these usability aspects. The results of the evaluation study revealed that the usability of the interface terminology fell short (SUS scores before and after implementation of 47.2 out of 100 and 37.5 respectively out of 100). The qualitative measurements revealed a high number (n=35) of distinct usability problems, leading to ineffective and inefficient registration of reasons for admission. The effectiveness and efficiency of the system did not change over time. About 14% (n=5) of the revealed usability problems were related to the terminology content based on SNOMED CT, while the remaining 86% (n=30) was related to the terminology application. The problems related to the terminology content were more severe than the problems related to the terminology application. This study provides a detailed insight into how clinicians interact with a controlled compositional terminology through a terminology application. The extensiveness, complexity of the hierarchy, and the language usage of an interface terminology are defining for its usability. Carefully crafted domain-specific subsets and a well-designed terminology application are needed to facilitate the use of a complex compositional interface terminology based on SNOMED CT. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. Usability of clinical decision support system as a facilitator for learning the assistive technology adaptation process.

    PubMed

    Danial-Saad, Alexandra; Kuflik, Tsvi; Weiss, Patrice L Tamar; Schreuer, Naomi

    2016-01-01

    The aim of this study was to evaluate the usability of Ontology Supported Computerized Assistive Technology Recommender (OSCAR), a Clinical Decision Support System (CDSS) for the assistive technology adaptation process, its impact on learning the matching process, and to determine the relationship between its usability and learnability. Two groups of expert and novice clinicians (total, n = 26) took part in this study. Each group filled out system usability scale (SUS) to evaluate OSCAR's usability. The novice group completed a learning questionnaire to assess OSCAR's effect on their ability to learn the matching process. Both groups rated OSCAR's usability as "very good", (M [SUS] = 80.7, SD = 11.6, median = 83.7) by the novices, and (M [SUS] = 81.2, SD = 6.8, median = 81.2) by the experts. The Mann-Whitney results indicated that no significant differences were found between the expert and novice groups in terms of OSCAR's usability. A significant positive correlation existed between the usability of OSCAR and the ability to learn the adaptation process (rs = 0.46, p = 0.04). Usability is an important factor in the acceptance of a system. The successful application of user-centered design principles during the development of OSCAR may serve as a case study that models the significant elements to be considered, theoretically and practically in developing other systems. Implications for Rehabilitation Creating a CDSS with a focus on its usability is an important factor for its acceptance by its users. Successful usability outcomes can impact the learning process of the subject matter in general, and the AT prescription process in particular. The successful application of User-Centered Design principles during the development of OSCAR may serve as a case study that models the significant elements to be considered, theoretically and practically. The study emphasizes the importance of close collaboration between the developers and the end users.

  12. Applying heuristic evaluation to improve the usability of a telemedicine system.

    PubMed

    Tang, Zhihua; Johnson, Todd R; Tindall, R Douglas; Zhang, Jiajie

    2006-02-01

    The development of a telemedicine system should not only take advantage of technological advances but also pay close attention to users and the human issues involved. In this paper we examine the utility of heuristic evaluation in improving the usability of a digital emergency medical services (EMS) system equipped on an ambulance. The digital EMS system used advanced communication technologies to help remotely located trauma specialists gain access to patient data in real-time and direct life-saving measures in a timely fashion. To improve its usability, three experts inspected prototypes of the system according to 14 software usability heuristics. The analyses revealed information on the prevalence, severity, and nature of heuristic violations in the user interface design. The results were subsequently utilized to guide the iterative software design process. A comparison between two consecutive prototypes showed that the second design had only half as many usability violations as the first prototype and had considerable improvement in a number of usability heuristic categories. The validity of heuristic evaluation was examined in an ethnographic study of paramedics using a prototype of the system in their work environment. Users' task performances partially verified heuristic evaluation results. However, they also revealed problems that were not identified in heuristic evaluation but only became prominent during field observation. In conclusion, we argue that usability should be given high priority in the development of a telemedicine system, and that heuristic evaluation can be an effective and efficient way to identify usability problems in the early stage of software development.

  13. Situated Usability Testing for Security Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greitzer, Frank L.

    2011-03-02

    While usability testing is well established, assessing the usability of security software, tools, or methods deserves more careful consideration. It has been argued that dealing with security has become too difficult for individuals or organizations to manage effectively or to use conveniently. As difficult as it is for system administrators and developers to deal with, security is even more challenging for casual users. Indeed, it is much too easy for casual/home users to configure the security of their systems in non-optimal ways that leave their systems inadvertently insecure. This is exacerbated by the fact that casual users are focused onmore » matters other than security, and likely would prefer not even to think about security. This brief report argues that when security and/or privacy are part of the equation, traditional methods for usability testing should be re-considered. The purpose of this brief report is to argue for and outline a method associated with a new approach to usability testing for examining usable security issues.« less

  14. Designing Telemedicine Systems for Geriatric Patients: A Review of the Usability Studies.

    PubMed

    Narasimha, Shraddhaa; Madathil, Kapil Chalil; Agnisarman, Sruthy; Rogers, Hunter; Welch, Brandon; Ashok, Aparna; Nair, Aswathi; McElligott, James

    2017-06-01

    One area where telemedicine may prove to be highly effective is in providing medical care to the geriatric population, an age group predicted to account for 20% of the population in the near future. However, even though telemedicine has certain advantages, the usability of these systems with this population merits investigation. This article reviews the literature published from 2000 to 2016 with the goal of analyzing the characteristics of usability-related studies conducted using geriatric participants and the subsequent usability challenges identified. Articles were found using Web of Knowledge and PubMed citation indexing portals using the keywords (1) Telemedicine* AND Geriatrics* (2) Telemedicine* AND Usability* (3) Telemedicine* AND Usability* AND Older Adults*. A total of 297 articles were obtained from the initial search. After further detailed screening, 16 articles were selected for review based on the inclusion criteria. Of these, 60% of the studies focused on the overall usability of telemedicine systems; 6.25% focused on the usability of a telepresence robot; 12.5% compared a face-to-face medical consultation with the use of telemedicine systems, and 25% focused on the study of other aspects of telemedicine in addition to its usability. Findings reported in the studies included high patient satisfaction with telemedicine in 31.25%, whereas another 31.25% indicated a high acceptance of this method of medical consultation. Care coordination in 6.25% of the studies; confidence in telemedicine in 6.25%; trust, privacy, and reliability in 6.25%; and increased convenience when compared to personal visits in 18.75% were also reported. This review suggests limited research providing scientifically valid and reproducible usability evaluation at various stages of telemedicine system development. Telemedicine system designers need to consider the age-related issues in cognition, perception, and behavior of geriatric patients while designing telemedicine applications. Future directions for research were developed based on the limitations as well as other results found in this systematic review.

  15. Usability and feasibility of health IT interventions to enhance Self-Care for Lymphedema Symptom Management in breast cancer survivors.

    PubMed

    Fu, Mei R; Axelrod, Deborah; Guth, Amber A; Wang, Yao; Scagliola, Joan; Hiotis, Karen; Rampertaap, Kavita; El-Shammaa, Nardin

    2016-09-01

    The-Optimal-Lymph-Flow health IT system (TOLF) is a patient-centered, web-and-mobile-based educational and behavioral health IT system focusing on safe, innovative, and pragmatic self-care strategies for lymphedema symptom management. The purpose of this study was to evaluate usability, feasibility, and acceptability of TOLF among the end-user of breast cancer survivors. Two types of usability testing were completed with 30 breast cancer survivors: heuristic evaluation and end-user testing. Each participant was asked to think aloud while completing a set of specified tasks designed to explicate and freely explore the system features. A heuristic evaluation checklist, the Perceived Ease of Use and Usefulness Questionnaire, and The Post Study System Usability Questionnaire were used to evaluate usability of the system. Open-ended questions were used to gather qualitative data. Quantitative data were analyzed using descriptive statistics and qualitative data were summarized thematically. Breast cancer survivors were very satisfied with the system: 90% (n = 27) rated the system having no usability problems; 10% (n = 3) noted minor cosmetic problems: spelling errors or text font size. The majority of participants 96.6% (n = 29) strongly agreed that the system was easy to use and effective in helping to learn about lymphedema, symptoms and self-care strategies. Themes from the qualitative data included empowerment, high quality information, loving avatar simulation videos, easy accessibility, and user-friendliness. This usability study provided evidence on breast cancer survivor's acceptance and highly positive evaluation of TOLF's usability as well as feasibility of using technologically-driven delivery model to enhance self-care strategies for lymphedema symptom management.

  16. A Framework for Usability Evaluation in EHR Procurement.

    PubMed

    Tyllinen, Mari; Kaipio, Johanna; Lääveri, Tinja

    2018-01-01

    Usability should be considered already by the procuring organizations when selecting future systems. In this paper, we present a framework for usability evaluation during electronic health record (EHR) system procurement. We describe the objectives of the evaluation, the procedure, selected usability attributes and the evaluation methods to measure them. We also present the emphasis usability had in the selection process. We do not elaborate on the details of the results, the application of methods or gathering of data. Instead we focus on the components of the framework to inform and give an example to other similar procurement projects.

  17. Usability evaluation of an emergency department information system prototype designed using cognitive systems engineering techniques.

    PubMed

    Clark, Lindsey N; Benda, Natalie C; Hegde, Sudeep; McGeorge, Nicolette M; Guarrera-Schick, Theresa K; Hettinger, A Zachary; LaVergne, David T; Perry, Shawna J; Wears, Robert L; Fairbanks, Rollin J; Bisantz, Ann M

    2017-04-01

    This article presents an evaluation of novel display concepts for an emergency department information system (EDIS) designed using cognitive systems engineering methods. EDISs assist emergency medicine staff with tracking patient care and ED resource allocation. Participants performed patient planning and orientation tasks using the EDIS displays and rated the display's ability to support various cognitive performance objectives along with the usability, usefulness, and predicted frequency of use for 18 system components. Mean ratings were positive for cognitive performance support objectives, usability, usefulness, and frequency of use, demonstrating the successful application of design methods to create useful and usable EDIS concepts that provide cognitive support for emergency medicine staff. Nurse and provider roles had significantly different perceptions of the usability and usefulness of certain EDIS components, suggesting that they have different information needs while working. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Usability evaluation of an emergency department information system prototype designed using cognitive systems engineering techniques

    PubMed Central

    Clark, Lindsey N.; Benda, Natalie C.; Hegde, Sudeep; McGeorge, Nicolette M.; Guarrera-Schick, Theresa K.; Hettinger, A. Zachary; LaVergne, David T.; Perry, Shawna J.; Wears, Robert L.; Fairbanks, Rollin J.; Bisantz, Ann M.

    2017-01-01

    This article presents an evaluation of novel display concepts for an emergency department information system (EDIS) designed using cognitive systems engineering methods. EDISs assist emergency medicine staff with tracking patient care and ED resource allocation. Participants performed patient planning and orientation tasks using the EDIS displays and rated the display’s ability to support various cognitive performance objectives along with the usability, usefulness, and predicted frequency of use for 18 system components. Mean ratings were positive for cognitive performance support objectives, usability, usefulness, and frequency of use, demonstrating the successful application of design methods to create useful and usable EDIS concepts that provide cognitive support for emergency medicine staff. Nurse and provider roles had significantly different perceptions of the usability and usefulness of certain EDIS components, suggesting that they have different information needs while working. PMID:28166896

  19. Integrating Low-Cost Rapid Usability Testing into Agile System Development of Healthcare IT: A Methodological Perspective.

    PubMed

    Kushniruk, Andre W; Borycki, Elizabeth M

    2015-01-01

    The development of more usable and effective healthcare information systems has become a critical issue. In the software industry methodologies such as agile and iterative development processes have emerged to lead to more effective and usable systems. These approaches highlight focusing on user needs and promoting iterative and flexible development practices. Evaluation and testing of iterative agile development cycles is considered an important part of the agile methodology and iterative processes for system design and re-design. However, the issue of how to effectively integrate usability testing methods into rapid and flexible agile design cycles has remained to be fully explored. In this paper we describe our application of an approach known as low-cost rapid usability testing as it has been applied within agile system development in healthcare. The advantages of the integrative approach are described, along with current methodological considerations.

  20. Measuring the Usability of Augmented Reality e-Learning Systems: A User-Centered Evaluation Approach

    NASA Astrophysics Data System (ADS)

    Pribeanu, Costin; Balog, Alexandru; Iordache, Dragoş Daniel

    The development of Augmented Reality (AR) systems is creating new challenges and opportunities for the designers of e-learning systems. The mix of real and virtual requires appropriate interaction techniques that have to be evaluated with users in order to avoid usability problems. Formative usability aims at finding usability problems as early as possible in the development life cycle and is suitable to support the development of such novel interactive systems. This work presents an approach to the user-centered usability evaluation of an e-learning scenario for Biology developed on an Augmented Reality educational platform. The evaluation has been carried on during and after a summer school held within the ARiSE research project. The basic idea was to perform usability evaluation twice. In this respect, we conducted user testing with a small number of students during the summer school in order to get a fast feedback from users having good knowledge in Biology. Then, we repeated the user testing in different conditions and with a relatively larger number of representative users. In this paper we describe both experiments and compare the usability evaluation results.

  1. The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System

    PubMed Central

    Bailey, Timothy; Bode, Bruce W.; Christiansen, Mark P.; Klaff, Leslie J.

    2015-01-01

    Abstract Introduction: The purpose of the study was to evaluate the performance and usability of the FreeStyle® Libre™ Flash glucose monitoring system (Abbott Diabetes Care, Alameda, CA) for interstitial glucose results compared with capillary blood glucose results. Materials and Methods: Seventy-two study participants with type 1 or type 2 diabetes were enrolled by four U.S. clinical sites. A sensor was inserted on the back of each upper arm for up to 14 days. Three factory-only calibrated sensor lots were used in the study. Sensor glucose measurements were compared with capillary blood glucose (BG) results (approximately eight per day) obtained using the BG meter built into the reader (BG reference) and with the YSI analyzer (Yellow Springs Instrument, Yellow Springs, OH) reference tests at three clinic visits (32 samples per visit). Sensor readings were masked to the participants. Results: The accuracy of the results was demonstrated against capillary BG reference values, with 86.7% of sensor results within Consensus Error Grid Zone A. The percentage of readings within Consensus Error Grid Zone A on Days 2, 7, and 14 was 88.4%, 89.2%, and 85.2%, respectively. The overall mean absolute relative difference was 11.4%. The mean lag time between sensor and YSI reference values was 4.5±4.8 min. Sensor accuracy was not affected by factors such as body mass index, age, type of diabetes, clinical site, insulin administration, or hemoglobin A1c. Conclusions: Interstitial glucose measurements with the FreeStyle Libre system were found to be accurate compared with capillary BG reference values, with accuracy remaining stable over 14 days of wear and unaffected by patient characteristics. PMID:26171659

  2. The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System.

    PubMed

    Bailey, Timothy; Bode, Bruce W; Christiansen, Mark P; Klaff, Leslie J; Alva, Shridhara

    2015-11-01

    The purpose of the study was to evaluate the performance and usability of the FreeStyle(®) Libre™ Flash glucose monitoring system (Abbott Diabetes Care, Alameda, CA) for interstitial glucose results compared with capillary blood glucose results. Seventy-two study participants with type 1 or type 2 diabetes were enrolled by four U.S. clinical sites. A sensor was inserted on the back of each upper arm for up to 14 days. Three factory-only calibrated sensor lots were used in the study. Sensor glucose measurements were compared with capillary blood glucose (BG) results (approximately eight per day) obtained using the BG meter built into the reader (BG reference) and with the YSI analyzer (Yellow Springs Instrument, Yellow Springs, OH) reference tests at three clinic visits (32 samples per visit). Sensor readings were masked to the participants. The accuracy of the results was demonstrated against capillary BG reference values, with 86.7% of sensor results within Consensus Error Grid Zone A. The percentage of readings within Consensus Error Grid Zone A on Days 2, 7, and 14 was 88.4%, 89.2%, and 85.2%, respectively. The overall mean absolute relative difference was 11.4%. The mean lag time between sensor and YSI reference values was 4.5±4.8 min. Sensor accuracy was not affected by factors such as body mass index, age, type of diabetes, clinical site, insulin administration, or hemoglobin A1c. Interstitial glucose measurements with the FreeStyle Libre system were found to be accurate compared with capillary BG reference values, with accuracy remaining stable over 14 days of wear and unaffected by patient characteristics.

  3. User Interface Problems of a Nationwide Inpatient Information System: A Heuristic Evaluation.

    PubMed

    Atashi, Alireza; Khajouei, Reza; Azizi, Amirabbas; Dadashi, Ali

    2016-01-01

    While studies have shown that usability evaluation could uncover many design problems of health information systems, the usability of health information systems in developing countries using their native language is poorly studied. The objective of this study was to evaluate the usability of a nationwide inpatient information system used in many academic hospitals in Iran. Three trained usability evaluators independently evaluated the system using Nielsen's 10 usability heuristics. The evaluators combined identified problems in a single list and independently rated the severity of the problems. We statistically compared the number and severity of problems identified by HIS experienced and non-experienced evaluators. A total of 158 usability problems were identified. After removing duplications 99 unique problems were left. The highest mismatch with usability principles was related to "Consistency and standards" heuristic (25%) and the lowest related to "Flexibility and efficiency of use" (4%). The average severity of problems ranged from 2.4 (Major problem) to 3.3 (Catastrophe problem). The experienced evaluator with HIS identified significantly more problems and gave higher severities to problems (p<0.02). Heuristic Evaluation identified a high number of usability problems in a widely used inpatient information system in many academic hospitals. These problems, if remain unsolved, may waste users' and patients' time, increase errors and finally threaten patient's safety. Many of them can be fixed with simple redesign solutions such as using clear labels and better layouts. This study suggests conducting further studies to confirm the findings concerning effect of evaluator experience on the results of Heuristic Evaluation.

  4. User Interface Problems of a Nationwide Inpatient Information System: A Heuristic Evaluation

    PubMed Central

    Atashi, Alireza; Azizi, Amirabbas; Dadashi, Ali

    2016-01-01

    Summary Introduction While studies have shown that usability evaluation could uncover many design problems of health information systems, the usability of health information systems in developing countries using their native language is poorly studied. The objective of this study was to evaluate the usability of a nationwide inpatient information system used in many academic hospitals in Iran. Material and Methods Three trained usability evaluators independently evaluated the system using Nielsen’s 10 usability heuristics. The evaluators combined identified problems in a single list and independently rated the severity of the problems. We statistically compared the number and severity of problems identified by HIS experienced and non-experienced evaluators. Results A total of 158 usability problems were identified. After removing duplications 99 unique problems were left. The highest mismatch with usability principles was related to “Consistency and standards” heuristic (25%) and the lowest related to “Flexibility and efficiency of use” (4%). The average severity of problems ranged from 2.4 (Major problem) to 3.3 (Catastrophe problem). The experienced evaluator with HIS identified significantly more problems and gave higher severities to problems (p<0.02). Discussion Heuristic Evaluation identified a high number of usability problems in a widely used inpatient information system in many academic hospitals. These problems, if remain unsolved, may waste users’ and patients’ time, increase errors and finally threaten patient’s safety. Many of them can be fixed with simple redesign solutions such as using clear labels and better layouts. This study suggests conducting further studies to confirm the findings concerning effect of evaluator experience on the results of Heuristic Evaluation. PMID:27081409

  5. Interface design recommendations for computerised clinical audit and feedback: Hybrid usability evidence from a research-led system.

    PubMed

    Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain

    2016-10-01

    Audit and Feedback (A&F) is a widely used quality improvement technique that measures clinicians' clinical performance and reports it back to them. Computerised A&F (e-A&F) system interfaces may consist of four key components: (1) Summaries of clinical performance; (2) Patient lists; (3) Patient-level data; (4) Recommended actions. There is a lack of evidence regarding how to best design e-A&F interfaces; establishing such evidence is key to maximising usability, and in turn improving patient safety. To evaluate the usability of a novel theoretically-informed and research-led e-A&F system for primary care (the Performance Improvement plaN GeneratoR: PINGR). (1) Describe PINGR's design, rationale and theoretical basis; (2) Identify usability issues with PINGR; (3) Understand how these issues may interfere with the cognitive goals of end-users; (4) Translate the issues into recommendations for the user-centred design of e-A&F systems. Eight experienced health system evaluators performed a usability inspection using an innovative hybrid approach consisting of five stages: (1) Development of representative user tasks, Goals, and Actions; (2) Combining Heuristic Evaluation and Cognitive Walkthrough methods into a single protocol to identify usability issues; (3) Consolidation of issues; (4) Severity rating of consolidated issues; (5) Analysis of issues according to usability heuristics, interface components, and Goal-Action structure. A final list of 47 issues were categorised into 8 heuristic themes. The most error-prone heuristics were 'Consistency and standards' (13 usability issues; 28% of the total) and 'Match between system and real world' (n=10, 21%). The recommended actions component of the PINGR interface had the most usability issues (n=21, 45%), followed by patient-level data (n=5, 11%), patient lists (n=4, 9%), and summaries of clinical performance (n=4, 9%). The most error-prone Actions across all user Goals were: (1) Patient selection from a list; (2) Data identification from a figure (both population-level and patient-level); (3) Disagreement with a system recommendation. By contextualising our findings within the wider literature on health information system usability, we provide recommendations for the design of e-A&F system interfaces relating to their four key components, in addition to how they may be integrated within a system. Copyright © 2016. Published by Elsevier Ireland Ltd.

  6. Evaluating Usability in a Distance Digital Systems Laboratory Class

    ERIC Educational Resources Information Center

    Kostaras, N.; Xenos, M.; Skodras, A. N.

    2011-01-01

    This paper presents the usability evaluation of a digital systems laboratory class offered to distance-learning students. It details the way in which students can participate remotely in such a laboratory, the methodology employed in the usability assessment of the laboratory infrastructure (hardware and software), and also outlines the main…

  7. Defining Usability: How Library Practice Differs from Published Research

    ERIC Educational Resources Information Center

    Chen, Yu-Hui; Germain, Carol Anne; Rorissa, Abebe

    2011-01-01

    Library/information science professionals need a clearly articulated definition of usability/Web usability to implement intuitive websites. In this study, the authors analyzed usability definitions provided by the ARL library professionals and those found in the library/information science and computer science-information systems literature.…

  8. An evaluation of patients' experienced usability of a diabetes mHealth system using a multi-method approach.

    PubMed

    Georgsson, Mattias; Staggers, Nancy

    2016-02-01

    mHealth systems are becoming more common to aid patients in their diabetes self-management, but recent studies indicate a need for thorough evaluation of patients' experienced usability. Current evaluations lack a multi-method design for data collection and structured methods for data analyses. The purpose of this study was to provide a feasibility test of a multi-method approach for both data collection and data analyses for patients' experienced usability of a mHealth system for diabetes type 2 self-management. A random sample of 10 users was selected from a larger clinical trial. Data collection methods included user testing with eight representative tasks and Think Aloud protocol, a semi-structured interview and a questionnaire on patients' experiences using the system. The Framework Analysis (FA) method and Usability Problem Taxonomy (UPT) were used to structure, code and analyze the results. A usability severity rating was assigned after classification. The combined methods resulted in a total of 117 problems condensed into 19 usability issues with an average severity rating of 2.47 or serious. The usability test detected 50% of the initial usability problems, followed by the post-interview at 29%. The usability test found 18 of 19 consolidated usability problems while the questionnaire uncovered one unique issue. Patients experienced most usability problems (8) in the Glucose Readings View when performing complex tasks such as adding, deleting, and exporting glucose measurements. The severity ratings were the highest for the Glucose Diary View, Glucose Readings View, and Blood Pressure View with an average severity rating of 3 (serious). Most of the issues were classified under the artifact component of the UPT and primary categories of Visualness (7) and Manipulation (6). In the UPT task component, most issues were in the primary category Task-mapping (12). Multiple data collection methods yielded a more comprehensive set of usability issues. Usability testing uncovered the largest volume of usability issues, followed by interviewing and then the questionnaire. The interview did not surface any unique consolidated usability issues while the questionnaire surfaced one. The FA and UPT were valuable in structuring and classifying problems. The resulting descriptions serve as a communication tool in problem solving and programming. We recommend the usage of multiple methods in data collection and employing the FA and UPT in data analyses for future usability testing. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  9. 77 FR 25707 - Submission for OMB Review; Comment request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-01

    ... and OMB Number: Electronic Health Record (EHR) Usability Survey; OMB Control Number 0720-TBD. Type of... information collection is to develop a longitudinal measure of how end-users perceive the usability of the... the focus has shifted towards understanding the usability of a system. This usability attribute...

  10. Evaluating a Web-Based Interface for Internet Telemedicine

    NASA Technical Reports Server (NTRS)

    Lathan, Corinna E.; Newman, Dava J.; Sebrechts, Marc M.; Doarn, Charles R.

    1997-01-01

    The objective is to introduce the usability engineering methodology, heuristic evaluation, to the design and development of a web-based telemedicine system. Using a set of usability criteria, or heuristics, one evaluator examined the Spacebridge to Russia web-site for usability problems. Thirty-four usability problems were found in this preliminary study and all were assigned a severity rating. The value of heuristic analysis in the iterative design of a system is shown because the problems can be fixed before deployment of a system and the problems are of a different nature than those found by actual users of the system. It was therefore determined that there is potential value of heuristic evaluation paired with user testing as a strategy for optimal system performance design.

  11. A systematic review of hybrid brain-computer interfaces: Taxonomy and usability perspectives

    PubMed Central

    Lee, Yushin; Yun, Myung Hwan

    2017-01-01

    A new Brain-Computer Interface (BCI) technique, which is called a hybrid BCI, has recently been proposed to address the limitations of conventional single BCI system. Although some hybrid BCI studies have shown promising results, the field of hybrid BCI is still in its infancy and there is much to be done. Especially, since the hybrid BCI systems are so complicated and complex, it is difficult to understand the constituent and role of a hybrid BCI system at a glance. Also, the complicated and complex systems make it difficult to evaluate the usability of the systems. We systematically reviewed and analyzed the current state-of-the-art hybrid BCI studies, and proposed a systematic taxonomy for classifying the types of hybrid BCIs with multiple taxonomic criteria. After reviewing 74 journal articles, hybrid BCIs could be categorized with respect to 1) the source of brain signals, 2) the characteristics of the brain signal, and 3) the characteristics of operation in each system. In addition, we exhaustively reviewed recent literature on usability of BCIs. To identify the key evaluation dimensions of usability, we focused on task and measurement characteristics of BCI usability. We classified and summarized 31 BCI usability journal articles according to task characteristics (type and description of task) and measurement characteristics (subjective and objective measures). Afterwards, we proposed usability dimensions for BCI and hybrid BCI systems according to three core-constructs: Satisfaction, effectiveness, and efficiency with recommendations for further research. This paper can help BCI researchers, even those who are new to the field, can easily understand the complex structure of the hybrid systems at a glance. Recommendations for future research can also be helpful in establishing research directions and gaining insight in how to solve ergonomics and HCI design issues surrounding BCI and hybrid BCI systems by usability evaluation. PMID:28453547

  12. A systematic review of hybrid brain-computer interfaces: Taxonomy and usability perspectives.

    PubMed

    Choi, Inchul; Rhiu, Ilsun; Lee, Yushin; Yun, Myung Hwan; Nam, Chang S

    2017-01-01

    A new Brain-Computer Interface (BCI) technique, which is called a hybrid BCI, has recently been proposed to address the limitations of conventional single BCI system. Although some hybrid BCI studies have shown promising results, the field of hybrid BCI is still in its infancy and there is much to be done. Especially, since the hybrid BCI systems are so complicated and complex, it is difficult to understand the constituent and role of a hybrid BCI system at a glance. Also, the complicated and complex systems make it difficult to evaluate the usability of the systems. We systematically reviewed and analyzed the current state-of-the-art hybrid BCI studies, and proposed a systematic taxonomy for classifying the types of hybrid BCIs with multiple taxonomic criteria. After reviewing 74 journal articles, hybrid BCIs could be categorized with respect to 1) the source of brain signals, 2) the characteristics of the brain signal, and 3) the characteristics of operation in each system. In addition, we exhaustively reviewed recent literature on usability of BCIs. To identify the key evaluation dimensions of usability, we focused on task and measurement characteristics of BCI usability. We classified and summarized 31 BCI usability journal articles according to task characteristics (type and description of task) and measurement characteristics (subjective and objective measures). Afterwards, we proposed usability dimensions for BCI and hybrid BCI systems according to three core-constructs: Satisfaction, effectiveness, and efficiency with recommendations for further research. This paper can help BCI researchers, even those who are new to the field, can easily understand the complex structure of the hybrid systems at a glance. Recommendations for future research can also be helpful in establishing research directions and gaining insight in how to solve ergonomics and HCI design issues surrounding BCI and hybrid BCI systems by usability evaluation.

  13. Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics.

    PubMed

    Georgsson, Mattias; Staggers, Nancy

    2016-01-01

    Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients' perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients' task performance, satisfaction, and the relationship of these measures to user characteristics. We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients' experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  14. Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics

    PubMed Central

    Staggers, Nancy

    2016-01-01

    Objective Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients’ perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients’ task performance, satisfaction, and the relationship of these measures to user characteristics. Materials and Methods We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Results Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Discussion Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Conclusion Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients’ experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems. PMID:26377990

  15. To twist or poke? A method for identifying usability issues with the rotary controller and touch screen for control of in-vehicle information systems.

    PubMed

    Harvey, Catherine; Stanton, Neville A; Pickering, Carl A; McDonald, Mike; Zheng, Pengjun

    2011-07-01

    In-vehicle information systems (IVIS) can be controlled by the user via direct or indirect input devices. In order to develop the next generation of usable IVIS, designers need to be able to evaluate and understand the usability issues associated with these two input types. The aim of this study was to investigate the effectiveness of a set of empirical usability evaluation methods for identifying important usability issues and distinguishing between the IVIS input devices. A number of usability issues were identified and their causal factors have been explored. These were related to the input type, the structure of the menu/tasks and hardware issues. In particular, the translation between inputs and on-screen actions and a lack of visual feedback for menu navigation resulted in lower levels of usability for the indirect device. This information will be useful in informing the design of new IVIS, with improved usability. STATEMENT OF RELEVANCE: This paper examines the use of empirical methods for distinguishing between direct and indirect IVIS input devices and identifying usability issues. Results have shown that the characteristics of indirect input devices produce more serious usability issues, compared with direct devices and can have a negative effect on the driver-vehicle interaction.

  16. Usability of patient-centered health IT: mixed-methods usability study of ePill.

    PubMed

    Schmidt-Kraepelin, Manuel; Dehling, Tobias; Sunyaev, Ali

    2014-01-01

    To facilitate use of patient-centered health IT applications in everyday life, a high degree of usability is required. Based on the example of a patient-centered web application, we propose a usability study design enabling developers and researchers to assess usability of patient-centered health IT applications and derive implications for their improvement. Our study design integrates tasks that subjects have to process, an associated questionnaire based on Perceived Ease of Use, Perceived Usefulness, Attitude Toward Using, and Behavioral Intention to Use, a System Usability Scale questionnaire, and focus groups. Application of the usability study design demonstrates its feasibility and provides insights for assessment of usability in related projects in research and practice.

  17. A usability evaluation toolkit for In-Vehicle Information Systems (IVISs).

    PubMed

    Harvey, Catherine; Stanton, Neville A; Pickering, Carl A; McDonald, Mike; Zheng, Pengjun

    2011-05-01

    Usability must be defined specifically for the context of use of the particular system under investigation. This specific context of use should also be used to guide the definition of specific usability criteria and the selection of appropriate evaluation methods. There are four principles which can guide the selection of evaluation methods, relating to the information required in the evaluation, the stage at which to apply methods, the resources required and the people involved in the evaluation. This paper presents a framework for the evaluation of usability in the context of In-Vehicle Information Systems (IVISs). This framework guides designers through defining usability criteria for an evaluation, selecting appropriate evaluation methods and applying those methods. These stages form an iterative process of design-evaluation-redesign with the overall aim of improving the usability of IVISs and enhancing the driving experience, without compromising the safety of the driver. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  18. Usability of a real-time tracked augmented reality display system in musculoskeletal injections

    NASA Astrophysics Data System (ADS)

    Baum, Zachary; Ungi, Tamas; Lasso, Andras; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Image-guided needle interventions are seldom performed with augmented reality guidance in clinical practice due to many workspace and usability restrictions. We propose a real-time optically tracked image overlay system to make image-guided musculoskeletal injections more efficient and assess its usability in a bed-side clinical environment. METHODS: An image overlay system consisting of an optically tracked viewbox, tablet computer, and semitransparent mirror allows users to navigate scanned patient volumetric images in real-time using software built on the open-source 3D Slicer application platform. A series of experiments were conducted to evaluate the latency and screen refresh rate of the system using different image resolutions. To assess the usability of the system and software, five medical professionals were asked to navigate patient images while using the overlay and completed a questionnaire to assess the system. RESULTS: In assessing the latency of the system with scanned images of varying size, screen refresh rates were approximately 5 FPS. The study showed that participants found using the image overlay system easy, and found the table-mounted system was significantly more usable and effective than the handheld system. CONCLUSION: It was determined that the system performs comparably with scanned images of varying size when assessing the latency of the system. During our usability study, participants preferred the table-mounted system over the handheld. The participants also felt that the system itself was simple to use and understand. With these results, the image overlay system shows promise for use in a clinical environment.

  19. Understanding Usability: Investigating an Integrated Design Environment and Management System

    ERIC Educational Resources Information Center

    Lee, Jason Chong; Wahid, Shahtab; McCrickard, D. Scott; Chewar, C. M.; Congleton, Ben

    2007-01-01

    Purpose: Decades of innovation in designing usable (and unusable) interfaces have resulted in a plethora of guidelines, usability methods, and other design tools. The purpose of this research is to develop ways for novice developers to effectively leverage and contribute to the large and growing body of usability knowledge and methods.…

  20. Physician satisfaction with a critical care clinical information system using a multimethod evaluation of usability.

    PubMed

    Hudson, Darren; Kushniruk, Andre; Borycki, Elizabeth; Zuege, Danny J

    2018-04-01

    Physician satisfaction with electronic medical records has often been poor. Usability has frequently been identified as a source for decreased satisfaction. While surveys can identify many issues, and are logistically easier to administer, they may miss issues identified using other methods This study sought to understand the level of physician satisfaction and usability issues associated with a critical care clinical information system (eCritical Alberta) implemented throughout the province of Alberta, Canada. All critical care attending physicians using the system were invited to participate in an online survey. Questions included components of the User Acceptance of Information Technology and Usability Questionnaire as well as free text feedback on system components. Physicians were also invited to participate in a think aloud test using simulated scenarios. The transcribed think aloud text and questionnaire were subjected to textual analysis. 82% of all eligible physicians completed the on-line survey (n = 61). Eight physicians were invited and seven completed the think aloud test. Overall satisfaction with the system was moderate. Usability was identified as a significant factor contributing to satisfaction. The major usability factors identified were system response time and layout. The think aloud component identified additional factors beyond those identified in the on-line survey. This study found a modestly high level of physician satisfaction with a province-wide clinical critical care information system. Usability continues to be a significant factor in physician satisfaction. Using multiple methods of evaluation can capture the benefits of a large sample size and deeper understanding of the issues. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. The Relationship between National Culture and the Usability of an E-Learning System

    ERIC Educational Resources Information Center

    Adeoye, Blessing; Wentling, Rose Mary

    2007-01-01

    The purpose of this study was to investigate possible relationships between national culture and the usability of an e-learning system. The theoretical frameworks that were used to guide this study were Hofstede's (1980) cultural dimensions, and Nielson's (1993) usability attributes. The sample for this study was composed of 24 international…

  2. Using Heuristic Evaluation to Improve Sepsis Alert Usability.

    PubMed

    Pertiwi, Ariani Arista Putri; Fraczkowski, Dan; Stogis, Sheryl L; Lopez, Karen Dunn

    2018-06-01

    Sepsis, life-threatening organ dysfunction in response to infection, is an alarmingly common and aggressive illness in US hospitals, especially for intensive care patients. Preventing sepsis deaths rests on the clinicians' ability to promptly recognize and treat sepsis. To aid early recognition, many organizations have employed clinician-facing electronic sepsis alert systems. However, the effectiveness of the alert relies on heavily on the visual interface, textual information, and overall usability. This article reports a usability inspection of a sepsis alert system. The authors found violations in 12 of the 14 usability principles and promote use of this method in practice to systematically identify usability problems. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Effective Usability Engineering in Healthcare: A Vision of Usable and Safer Healthcare IT.

    PubMed

    Kushniruk, Andre; Senathirajah, Yalini; Borycki, Elizabeth

    2017-01-01

    Persistent problems with healthcare IT that is unusable and unsafe have been reported worldwide. In this paper we present our vision for deploying usability engineering in healthcare in a more substantive way in order to improve the current situation. The argument will be made that stronger and more substantial efforts need to be made to bring multiple usability engineering methods to bear on points in both system design and deployment (and not just as a one-time effort restricted to software product development). In addition, improved processes for ensuring the usability of commercial vendor-based systems being implemented in healthcare organizations need to be addressed. A discussion will also be provided on challenges and barriers that will need to be overcome to ensure that the heatlhcare IT that is released is both usable and safe.

  4. Usability Evaluation of a Clinical Decision Support System for Geriatric ED Pain Treatment.

    PubMed

    Genes, Nicholas; Kim, Min Soon; Thum, Frederick L; Rivera, Laura; Beato, Rosemary; Song, Carolyn; Soriano, Jared; Kannry, Joseph; Baumlin, Kevin; Hwang, Ula

    2016-01-01

    Older adults are at risk for inadequate emergency department (ED) pain care. Unrelieved acute pain is associated with poor outcomes. Clinical decision support systems (CDSS) hold promise to improve patient care, but CDSS quality varies widely, particularly when usability evaluation is not employed. To conduct an iterative usability and redesign process of a novel geriatric abdominal pain care CDSS. We hypothesized this process would result in the creation of more usable and favorable pain care interventions. Thirteen emergency physicians familiar with the Electronic Health Record (EHR) in use at the study site were recruited. Over a 10-week period, 17 1-hour usability test sessions were conducted across 3 rounds of testing. Participants were given 3 patient scenarios and provided simulated clinical care using the EHR, while interacting with the CDSS interventions. Quantitative System Usability Scores (SUS), favorability scores and qualitative narrative feedback were collected for each session. Using a multi-step review process by an interdisciplinary team, positive and negative usability issues in effectiveness, efficiency, and satisfaction were considered, prioritized and incorporated in the iterative redesign process of the CDSS. Video analysis was used to determine the appropriateness of the CDS appearances during simulated clinical care. Over the 3 rounds of usability evaluations and subsequent redesign processes, mean SUS progressively improved from 74.8 to 81.2 to 88.9; mean favorability scores improved from 3.23 to 4.29 (1 worst, 5 best). Video analysis revealed that, in the course of the iterative redesign processes, rates of physicians' acknowledgment of CDS interventions increased, however most rates of desired actions by physicians (such as more frequent pain score updates) decreased. The iterative usability redesign process was instrumental in improving the usability of the CDSS; if implemented in practice, it could improve geriatric pain care. The usability evaluation process led to improved acknowledgement and favorability. Incorporating usability testing when designing CDSS interventions for studies may be effective to enhance clinician use.

  5. From Usability Engineering to Evidence-based Usability in Health IT.

    PubMed

    Marcilly, Romaric; Peute, Linda; Beuscart-Zephir, Marie-Catherine

    2016-01-01

    Usability is a critical factor in the acceptance, safe use, and success of health IT. The User-Centred Design process is widely promoted to improve usability. However, this traditional case by case approach that is rooted in the sound understanding of users' needs is not sufficient to improve technologies' usability and prevent usability-induced use-errors that may harm patients. It should be enriched with empirical evidence. This evidence is on design elements (what are the most valuable design principles, and the worst usability mistakes), and on the usability evaluation methods (which combination of methods is most suitable in which context). To achieve this evidence, several steps must be fulfilled and challenges must be overcome. Some attempts to search evidence for designing elements of health IT and for usability evaluation methods exist and are summarized. A concrete instance of evidence-based usability design principles for medication-related alerting systems is briefly described.

  6. Hello World! - Experiencing Usability Methods without Usability Expertise

    NASA Astrophysics Data System (ADS)

    Eriksson, Elina; Cajander, Åsa; Gulliksen, Jan

    How do you do usability work when no usability expertise is available? What happens in an organization when system developers, with no previous HCI knowledge, after a 3-day course, start applying usability methods, and particularly field studies? In order to answer these questions qualitative data were gathered through participatory observations, a feed back survey, field study documentation and interviews from 47 system developers from a public authority. Our results suggest that field studies enhance the developer’s understanding of the user perspective, and provide a more holistic overview of the use situation, but that some developers were unable to interpret their observations and see solutions to the users’ problems. The field study method was very much appreciated and has now become standard operating procedure within the organization. However, although field studies may be useful, it does not replace the need for usability pro fes sion als, as their knowledge is essential for more complex observations, analysis and for keeping the focus on usability.

  7. Usability in telemedicine systems-A literature survey.

    PubMed

    Klaassen, B; van Beijnum, B J F; Hermens, H J

    2016-09-01

    The rapid development of sensors and communication technologies enable the growth of new innovative services in healthcare, such as Telemedicine. An essential ingredient in the development of a telemedicine system and its final acceptance by end users are usability studies. The principles of usability engineering, evaluations and telemedicine are well established, and it may contribute to the adoption and eventually deployment of such systems and services. An in-depth usability analysis, including performance and attitude measures, requires knowledge about available usability techniques, and is depending on the amount of resources. Therefore it is worth investigating how usability methods are applied in developing telemedicine systems. Our hypothesis is: with increasing research and development of telemedicine systems, we expect that various usability methods are more equally employed for different end-user groups and applications. A literature survey was conducted to find telemedicine systems that have been evaluated for usability or ease of use. The elements of the PICO framework were used as a basis for the selection criteria in the literature search. The search was not limited by year. Two independent reviewers screened all search results first by title, and then by abstract for inclusion. Articles were included up to May 2015. In total, 127 publications were included in this survey. The number of publications on telemedicine systems significantly increased after 2008. Older adults and end-users with cardiovascular conditions were among largest target end-user groups. Remote monitoring systems were found the most, in 90 publications. Questionnaires are the most common means for evaluating telemedicine systems, and were found in 88 publications. Questionnaires are used frequently in studies focusing on cardiovascular diseases, Parkinson's disease and older adult conditions. Interviews are found the most in publications related to stroke. In total 71% of the publications were trial-orientated and the remaining process orientated. An increase in telemedicine research, development and applications is found worldwide, with the majority of publications conducted in America. Monitoring patients in their homes can lead to better healthcare at lower costs which implies an increased demand of new healthcare strategies like telemedicine. We expected that with the increase in telemedicine research and development, a greater range of usability methods would also be employed in the included publications. This is not the case. Researchers employed questionnaires as a preferred usability method for each type of telemedicine system and most end-users. However, in process-orientated studies a greater range of usability evaluations were applied, with fewer differences found in the amount of publications for each evaluation method. Questionnaires enable researchers to evaluate a system quickly on end users, as it requires less expertise on the evaluation method compared to the other methods. They are easily distributed and are customizable. The use of questionnaires is therefore an evaluation method of choice for a variety of telemedicine systems and end-users. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. LATCH usability in vehicles.

    DOT National Transportation Integrated Search

    2012-04-01

    This project investigated the usability of Lower Anchors and Tethers for CHildren (LATCH) hardware by measuring LATCH implementations in 98 2011 or 2010 model-year vehicles. ISO and SAE LATCH usability rating systems were used to assess all vehicles ...

  9. Comparison of heuristic and cognitive walkthrough usability evaluation methods for evaluating health information systems.

    PubMed

    Khajouei, Reza; Zahiri Esfahani, Misagh; Jahani, Yunes

    2017-04-01

    There are several user-based and expert-based usability evaluation methods that may perform differently according to the context in which they are used. The objective of this study was to compare 2 expert-based methods, heuristic evaluation (HE) and cognitive walkthrough (CW), for evaluating usability of health care information systems. Five evaluators independently evaluated a medical office management system using HE and CW. We compared the 2 methods in terms of the number of identified usability problems, their severity, and the coverage of each method. In total, 156 problems were identified using the 2 methods. HE identified a significantly higher number of problems related to the "satisfaction" attribute ( P  = .002). The number of problems identified using CW concerning the "learnability" attribute was significantly higher than those identified using HE ( P  = .005). There was no significant difference between the number of problems identified by HE, based on different usability attributes ( P  = .232). Results of CW showed a significant difference between the number of problems related to usability attributes ( P  < .0001). The average severity of problems identified using CW was significantly higher than that of HE ( P  < .0001). This study showed that HE and CW do not differ significantly in terms of the number of usability problems identified, but they differ based on the severity of problems and the coverage of some usability attributes. The results suggest that CW would be the preferred method for evaluating systems intended for novice users and HE for users who have experience with similar systems. However, more studies are needed to support this finding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  10. Lessons learned from the usability assessment of home-based telemedicine systems.

    PubMed

    Agnisarman, Sruthy Orozhiyathumana; Chalil Madathil, Kapil; Smith, Kevin; Ashok, Aparna; Welch, Brandon; McElligott, James T

    2017-01-01

    At-home telemedicine visits are quickly becoming an acceptable alternative for in-person patient visits. However, little work has been done to understand the usability of these home-based telemedicine solutions. It is critical for user acceptance and real-world applicability to evaluate available telemedicine solutions within the context-specific needs of the users of this technology. To address this need, this study evaluated the usability of four home-based telemedicine software platforms: Doxy.me, Vidyo, VSee, and Polycom. Using a within-subjects experimental design, twenty participants were asked to complete a telemedicine session involving several tasks using the four platforms. Upon completion of these tasks for each platform, participants completed the IBM computer system usability questionnaire (CSUQ) and the NASA Task Load Index test. Upon completing the tasks on all four platforms, the participants completed a final post-test subjective questionnaire ranking the platforms based on their preference. Of the twenty participants, 19 completed the study. Statistically significant differences among the telemedicine software platforms were found for task completion time, total workload, mental demand, effort, frustration, preference ranking and computer system usability scores. Usability problems with installation and account creation led to high mental demand and task completion time, suggesting the participants preferred a system without such requirements. Majority of the usability issues were identified at the telemedicine initiation phase. The findings from this study can be used by software developers to develop user-friendly telemedicine systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Developing a Self-Report-Based Sequential Analysis Method for Educational Technology Systems: A Process-Based Usability Evaluation

    ERIC Educational Resources Information Center

    Lin, Yi-Chun; Hsieh, Ya-Hui; Hou, Huei-Tse

    2015-01-01

    The development of a usability evaluation method for educational systems or applications, called the self-report-based sequential analysis, is described herein. The method aims to extend the current practice by proposing self-report-based sequential analysis as a new usability method, which integrates the advantages of self-report in survey…

  12. A usability study of CPOE's medication administration functions: impact on physician-nurse cooperation.

    PubMed

    Beuscart-Zéphir, Marie Catherine; Pelayo, Sylvia; Degoulet, Patrice; Anceaux, Françoise; Guerlinger, Sandra; Meaux, Jean-Jacques

    2004-01-01

    Implementation of CPOE systems in Healthcare Institutions has proven efficient in reducing medication errors but it also induces hidden side-effects on Doctor-Nurse cooperation. We propose a usability engineering approach to this problem. An extensive activity analysis of the medication ordering and administration process was performed in several departments of 3 different hospitals. Two of these hospitals are still using paper-based orders, while the 3rd one is in the roll-out phase of medication functions of its CPOE system. We performed a usability assessment of this CPOE system. The usability assessment uncovered usability problems for the entry of medication administration time scheduling by the physician and revealed that the information can be ambiguous for the nurse. The comparison of cooperation models in both situation shows that users tend to adopt a distributed decision making paradigm in the paper-based situation, while the CPOE system supports a centralized decision making process. This analysis can support recommendation for the re-engineering of the Human-Computer Interface.

  13. Integration of MSFC Usability Lab with Usability Testing

    NASA Technical Reports Server (NTRS)

    Cheng, Yiwei; Richardson, Sally

    2010-01-01

    As part of the Stage Analysis Branch, human factors engineering plays an important role in relating humans to the systems of hardware and structure designs of the new launch vehicle. While many branches are involved in the technical aspects of creating a launch vehicle, human factors connects humans to the scientific systems with the goal of improving operational performance and safety while reducing operational error and damage to the hardware. Human factors engineers use physical and computerized models to visualize possible areas for improvements to ensure human accessibility to components requiring maintenance and that the necessary maintenance activities can be accomplished with minimal risks to human and hardware. Many methods of testing are used to fulfill this goal, such as physical mockups, computerized visualization, and usability testing. In this analysis, a usability test is conducted to test how usable a website is to users who are and are not familiar with it. The testing is performed using participants and Morae software to record and analyze the results. This analysis will be a preliminary test of the usability lab in preparation for use in new spacecraft programs, NASA Enterprise, or other NASA websites. The usability lab project is divided into two parts: integration of the usability lab and a preliminary test of the usability lab.

  14. Usability Laboratory Test of a Novel Mobile Homecare Application with Experienced Home Help Service Staff

    PubMed Central

    Scandurra, I; Hägglund, M; Koch, S; Lind, M

    2008-01-01

    Using participatory design, we developed and deployed a mobile Virtual Health Record (VHR) on a personal digital assistant (PDA) together with experienced homecare staff. To assess transferability to a second setting and usability when used by novice users with limited system education the application was tested in a usability lab. Eight participants from another homecare district performed tasks related to daily homecare work using the VHR. Test protocols were analyzed with regard to effectiveness, potential usability problems and user satisfaction. Usability problems having impact on system performance and contextual factors affecting system transferability were uncovered. Questionnaires revealed that the participants frequently used computers, but never PDAs. Surprisingly there were only minor differences in input efficiency between novice and experienced users. The participants were overall satisfied with the application. However, transfer to another district can not be performed, unless by means of careful field observations of contextual differences. PMID:19415140

  15. Optimizing the user interface of a data entry module for an electronic patient record for cardiac rehabilitation: A mixed method usability approach.

    PubMed

    van Engen-Verheul, Mariëtte M; Peute, Linda W P; de Keizer, Nicolette F; Peek, Niels; Jaspers, Monique W M

    2016-03-01

    Cumbersome electronic patient record (EPR) interfaces may complicate data-entry in clinical practice. Completeness of data entered in the EPR determines, among other things, the value of computerized clinical decision support (CCDS). Quantitative usability evaluations can provide insight into mismatches between the system design model of data entry and users' data entry behavior, but not into the underlying causes for these mismatches. Mixed method usability evaluation studies may provide these insights, and thus support generating redesign recommendations for improving an EPR system's data entry interface. To improve the usability of the data entry interface of an EPR system with CCDS in the field of cardiac rehabilitation (CR), and additionally, to assess the value of a mixed method usability approach in this context. Seven CR professionals performed a think-aloud usability evaluation both before (beta-version) and after the redesign of the system. Observed usability problems from both evaluations were analyzed and categorized using Zhang et al.'s heuristic principles of good interface design. We combined the think-aloud usability evaluation of the system's beta-version with the measurement of a new usability construct: users' deviations in action sequence from the system's predefined data entry order sequence. Recommendations for redesign were implemented. We assessed whether the redesign improved CR professionals' (1) task efficacy (with respect to the completeness of data they collected), and (2) task efficiency (with respect to the average number of mouse clicks they needed to complete data entry subtasks). With the system's beta version, 40% of health care professionals' navigation actions through the system deviated from the predefined next system action. The causes for these deviations as revealed by the think-aloud method mostly concerned mismatches between the system design model for data entry action sequences and users expectations of these action sequences, based on their paper-based daily routines. This caused non completion of data entry tasks (31% of main tasks completed), and more navigation actions than minimally required (146% of the minimum required). In the redesigned system the data entry navigational structure was organized in a flexible way around an overview screen to better mimic users' paper-based daily routines of collecting patient data. This redesign resulted in an increased number of completed main tasks (70%) and a decrease in navigation actions (133% of the minimum required). The think-aloud usability evaluation of the redesigned system showed that remaining problems concerned flexibility (e.g., lack of customization options) and consistency (mainly with layout and position of items on the screen). The mixed method usability evaluation was supportive in revealing the magnitude and causes of mismatches between the system design model of data-entry with users' data entry behavior. However, as both task efficacy and efficiency were still not optimal with the redesigned EPR, we advise to perform a cognitive analysis on end users' mental processes and behavior patterns in daily work processes specifically during the requirements analysis phase of development of interactive healthcare information systems. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Applying usability heuristics to radiotherapy systems.

    PubMed

    Chan, Alvita J; Islam, Mohammad K; Rosewall, Tara; Jaffray, David A; Easty, Anthony C; Cafazzo, Joseph A

    2012-01-01

    Heuristic evaluations have been used to evaluate safety of medical devices by identifying and assessing usability issues. Since radiotherapy treatment delivery systems often consist of multiple complex user-interfaces, a heuristic evaluation was conducted to assess the potential safety issues of such a system. A heuristic evaluation was conducted to evaluate the treatment delivery system at Princess Margaret Hospital (Toronto, Canada). Two independent evaluators identified usability issues with the user-interfaces and rated the severity of each issue. The evaluators identified 75 usability issues in total. Eighteen of them were rated as high severity, indicating the potential to have a major impact on patient safety. A majority of issues were found on the record and verify system, and many were associated with the patient setup process. While the hospital has processes in place to ensure patient safety, recommendations were developed to further mitigate the risks of potential consequences. Heuristic evaluation is an efficient and inexpensive method that can be successfully applied to radiotherapy delivery systems to identify usability issues and improve patient safety. Although this study was conducted only at one site, the findings may have broad implications for the design of these systems. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Evaluation of Nursing Information Systems: Application of Usability Aspects in the Development of Systems.

    PubMed

    Moghaddasi, Hamid; Rabiei, Reza; Asadi, Farkhondeh; Ostvan, Negin

    2017-04-01

    As the largest group providing healthcare services, nurses require well-designed information systems in their practice. This study aims to evaluate the usability of nursing information systems (NIS). This cross-sectional survey was conducted in 2015. The settings of the study consisted of four hospitals affiliated with three medical universities in Tehran (Iran). The subjects of the study included nurses who had access to and used a NIS developed by four major software companies. The data were collected using a modified version of a usability questionnaire known as IsoMetrics, based on the International Standard ISO 9241, Part 11. The questionnaire is composed of 35 questions divided into seven general criteria. The validity of the questionnaire was determined by experts in the field, and the reliability was checked using Cronbach's alpha (α = 0.91). The questionnaire was then distributed to 184 nurses. The response rate was 64.6%. Among the seven ISO usability criteria, suitability for the task (3.10 ± 1.24) and suitability for learning (3.10 ± 1.27) had the highest mean value. The lowest mean value (2.37 ± 1.29) was related to the suitability for individualization. Addressing issues related to individualization and self-descriptiveness could improve the usability of nursing systems. Considering usability requirements in the design of a NIS will lead to the efficient and effective use of these systems.

  18. Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume.

    PubMed

    Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U

    2018-06-01

    Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.

  19. Safety and usability evaluation of a web-based insulin self-titration system for patients with type 2 diabetes mellitus.

    PubMed

    Simon, Airin C R; Holleman, Frits; Gude, Wouter T; Hoekstra, Joost B L; Peute, Linda W; Jaspers, Monique W M; Peek, Niels

    2013-09-01

    The rising incidence of type 2 diabetes mellitus (T2DM) induces severe challenges for the health care system. Our research group developed a web-based system named PANDIT that provides T2DM patients with insulin dosing advice using state of the art clinical decision support technology. The PANDIT interface resembles a glucose diary and provides advice through pop-up messages. Diabetes nurses (DNs) also have access to the system, allowing them to intervene when needed. The objective of this study was to establish whether T2DM patients can safely use PANDIT at home. To this end, we assessed whether patients experience usability problems with a high risk of compromising patient safety when interacting with the system, and whether PANDIT's insulin dosing advice are clinically safe. The study population consisted of patients with T2DM (aged 18-80) who used a once daily basal insulin as well as DNs from a university hospital. The usability evaluation consisted of think-aloud sessions with four patients and three DNs. Video data, audio data and verbal utterances were analyzed for usability problems encountered during PANDIT interactions. Usability problems were rated by a physician and a usability expert according to their potential impact on patient safety. The usability evaluation was followed by an implementation with a duration of four weeks. This implementation took place at the patients' homes with ten patients to evaluate clinical safety of PANDIT advice. PANDIT advice were systematically compared with DN advice. Deviating advice were evaluated with respect to patient safety by a panel of experienced physicians, which specialized in diabetes care. We detected seventeen unique usability problems, none of which was judged to have a high risk of compromising patient safety. Most usability problems concerned the lay-out of the diary, which did not clearly indicate which data entry fields had to be entered in order to obtain an advice. 27 out of 74 (36.5%) PANDIT advice differed from those provided by DNs. However, only one of these (1.4%) was considered unsafe by the panel. T2DM patients with no prior experience with the web-based self-management system were capable of consulting the system without encountering significant usability problems. Furthermore, the large majority of PANDIT advice were considered clinically safe according to the expert panel. One advice was considered unsafe. This could however easily be corrected by implementing a small modification to the system's knowledge base. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Comparison of Post-detonation Combustion in Explosives Incorporating Aluminum Nanoparticles: Influence of the Passivation Layer (Postprint)

    DTIC Science & Technology

    2013-01-31

    meters away from the explosive charge. The collection optic were aligned to view the center of each charge through a BK7 glass view- port. The...Basler Sprint ) with a data collection rate of 1–70 kHz. The resolution and usable spectral range of the spectrograph were 1.2 nm and 380–720 nm...RDX 20 wt. % AlOA in RDX 20 wt. % AlFA in RDX 0 … … … 15 … 4000 ( 400 ) … 30 3900 (200) 4500 (500) 3200 (300) 45 3600 (300) 򓇨 3400 (500) 044907-3

  1. Evaluating the usability of speech recognition to create clinical documentation using a commercial electronic health record.

    PubMed

    Hodgson, Tobias; Magrabi, Farah; Coiera, Enrico

    2018-05-01

    To conduct a usability study exploring the value of using speech recognition (SR) for clinical documentation tasks within an electronic health record (EHR) system. Thirty-five emergency department clinicians completed a system usability scale (SUS) questionnaire. The study was undertaken after participants undertook randomly allocated clinical documentation tasks using keyboard and mouse (KBM) or SR. SUS scores were analyzed and the results with KBM were compared to SR results. Significant difference in SUS scores between EHR system use with and without SR were observed (KBM 67, SR 61; P = 0.045; CI, 0.1 to 12.0). Nineteen of 35 participants scored higher for EHR with KBM, 11 higher for EHR with SR and 5 gave the same score for both. Factor analysis showed no significant difference in scores for the sub-element of usability (EHR with KBM 65, EHR with SR 62; P = 0.255; CI, -2.6 to 9.5). Scores for the sub-element of learnability were significantly different (KBM 72, SR 55; P < 0.001; CI, 9.8 to 23.5). A significant correlation was found between the perceived usability of the two system configurations (EHR with KBM or SR) and the efficiency of documentation (time to document) (P = 0.002; CI, 10.5 to -0.1) but not with safety (number of errors) (P = 0.90; CI, -2.3 to 2.6). SR was associated with significantly reduced overall usability scores, even though it is often positioned as ease of use technology. SR was perceived to impose larger costs in terms of learnability via training and support requirements for EHR based documentation when compared to using KBM. Lower usability scores were significantly associated with longer documentation times. The usability of EHR systems with any input modality is an area that requires continued development. The addition of an SR component to an EHR system may cause a significant reduction in terms of perceived usability by clinicians. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Usability/Sentiment for the Enterprise and ENTERPRISE

    NASA Technical Reports Server (NTRS)

    Meza, David; Berndt, Sarah

    2014-01-01

    The purpose of the Sentiment of Search Study for NASA Johnson Space Center (JSC) is to gain insight into the intranet search environment. With an initial usability survey, the authors were able to determine a usability score based on the Systems Usability Scale (SUS). Created in 1986, the freely available, well cited, SUS is commonly used to determine user perceptions of a system (in this case the intranet search environment). As with any improvement initiative, one must first examine and document the current reality of the situation. In this scenario, a method was needed to determine the usability of a search interface in addition to the user's perception on how well the search system was providing results. The use of the SUS provided a mechanism to quickly ascertain information in both areas, by adding one additional open-ended question at the end. The first ten questions allowed us to examine the usability of the system, while the last questions informed us on how the users rated the performance of the search results. The final analysis provides us with a better understanding of the current situation and areas to focus on for improvement. The power of search applications to enhance knowledge transfer is indisputable. The performance impact for any user unable to find needed information undermines project lifecycle, resource and scheduling requirements. Ever-increasing complexity of content and the user interface make usability considerations for the intranet, especially for search, a necessity instead of a 'nice-to-have'. Despite these arguments, intranet usability is largely disregarded due to lack of attention beyond the functionality of the infrastructure (White, 2013). The data collected from users of the JSC search system revealed their overall sentiment by means of the widely-known System Usability Scale. Results of the scores suggest 75%, +/-0.04, of the population rank the search system below average. In terms of a grading scaled, this equated to D or lower. It is obvious JSC users are not satisfied with the current situation, however they are eager to provide information and assistance in improving the search system. A majority of the respondents provided feedback on the issues most troubling them. This information will be used to enrich the next phase, root cause analysis and solution creation.

  3. A flight evaluation of VTOL jet transport under visual and simulated instrument conditions

    NASA Technical Reports Server (NTRS)

    Holzhauser, C. A.; Morello, S. A.; Innis, R. C.; Patton, J. M., Jr.

    1972-01-01

    A flight investigation was performed with the Dornier DO-31 VTOL to evaluate the performance, handling qualities, and operating characteristics that are considered to be important in the operation of a commerical VTOL transport in the terminal area. The DO-31, a 20,000 kilogram transport, has a mixed jet propulsion system; main engines with nozzles deflect from a cruise to a hover position, and vertical lift engines operated below 170 knots. This VTOL mode incorporates pitch and roll attitude and yaw rate stabilization. The tests concentrated on the transition, approach, and vertical landing. The mixed jet propulsion system provided a large usable performance envelope that enabled simulated IFR approaches to be made on 7 deg and 12 deg glide slopes. In these approaches management of thrust magnitude and direction was a primary problem, and some form of integrating the controls will be necessary. The handling qualities evaluation pointed out the need for additional research of define flight path criteria. The aircraft had satisfactory control and stability in hover out of ground effect. The recirculation effects in vertical landing were large below 15 meters.

  4. A Wide-field Camera and Fully Remote Operations at the Wyoming Infrared Observatory

    NASA Astrophysics Data System (ADS)

    Findlay, Joseph R.; Kobulnicky, Henry A.; Weger, James S.; Bucher, Gerald A.; Perry, Marvin C.; Myers, Adam D.; Pierce, Michael J.; Vogel, Conrad

    2016-11-01

    Upgrades at the 2.3 meter Wyoming Infrared Observatory telescope have provided the capability for fully remote operations by a single operator from the University of Wyoming campus. A line-of-sight 300 Megabit s-1 11 GHz radio link provides high-speed internet for data transfer and remote operations that include several realtime video feeds. Uninterruptable power is ensured by a 10 kVA battery supply for critical systems and a 55 kW autostart diesel generator capable of running the entire observatory for up to a week. The construction of a new four-element prime-focus corrector with fused-silica elements allows imaging over a 40‧ field of view with a new 40962 UV-sensitive prime-focus camera and filter wheel. A new telescope control system facilitates the remote operations model and provides 20″ rms pointing over the usable sky. Taken together, these improvements pave the way for a new generation of sky surveys supporting space-based missions and flexible-cadence observations advancing emerging astrophysical priorities such as planet detection, quasar variability, and long-term time-domain campaigns.

  5. Usability Prediction & Ranking of SDLC Models Using Fuzzy Hierarchical Usability Model

    NASA Astrophysics Data System (ADS)

    Gupta, Deepak; Ahlawat, Anil K.; Sagar, Kalpna

    2017-06-01

    Evaluation of software quality is an important aspect for controlling and managing the software. By such evaluation, improvements in software process can be made. The software quality is significantly dependent on software usability. Many researchers have proposed numbers of usability models. Each model considers a set of usability factors but do not cover all the usability aspects. Practical implementation of these models is still missing, as there is a lack of precise definition of usability. Also, it is very difficult to integrate these models into current software engineering practices. In order to overcome these challenges, this paper aims to define the term `usability' using the proposed hierarchical usability model with its detailed taxonomy. The taxonomy considers generic evaluation criteria for identifying the quality components, which brings together factors, attributes and characteristics defined in various HCI and software models. For the first time, the usability model is also implemented to predict more accurate usability values. The proposed system is named as fuzzy hierarchical usability model that can be easily integrated into the current software engineering practices. In order to validate the work, a dataset of six software development life cycle models is created and employed. These models are ranked according to their predicted usability values. This research also focuses on the detailed comparison of proposed model with the existing usability models.

  6. CUNY+ Web: Usability Study of the Web-Based GUI Version of the Bibliographic Database of the City University of New York (CUNY).

    ERIC Educational Resources Information Center

    Oulanov, Alexei; Pajarillo, Edmund J. Y.

    2002-01-01

    Describes the usability evaluation of the CUNY (City University of New York) information system in Web and Graphical User Interface (GUI) versions. Compares results to an earlier usability study of the basic information database available on CUNY's wide-area network and describes the applicability of the previous usability instrument to this…

  7. Proposing Electronic Health Record Usability Requirements Based on Enriched ISO 9241 Metric Usability Model

    PubMed Central

    Farzandipour, Mehrdad; Riazi, Hossein; Jabali, Monireh Sadeqi

    2018-01-01

    Introduction: System usability assessment is among the important aspects in assessing the quality of clinical information technology, especially when the end users of the system are concerned. This study aims at providing a comprehensive list of system usability. Methods: This research is a descriptive cross-sectional one conducted using Delphi technique in three phases in 2013. After experts’ ideas were concluded, the final version of the questionnaire including 163 items in three phases was presented to 40 users of information systems in hospitals. The grading ranged from 0-4. Data analysis was conducted using SPSS software. Those requirements with a mean point of three or higher were finally confirmed. Results: The list of system usability requirements for electronic health record was designed and confirmed in nine areas including suitability for the task (24 items), self-descriptiveness (22 items), controllability (19 questions), conformity with user expectations (25 items), error tolerance (21 items), suitability for individualization (7 items), suitability for learning (19 items), visual clarity (18 items) and auditory presentation (8 items). Conclusion: A relatively comprehensive model including useful requirements for using EHR was presented which can increase functionality, effectiveness and users’ satisfaction. Thus, it is suggested that the present model be adopted by system designers and healthcare system institutions to assess those systems. PMID:29719310

  8. Low-Cost Rapid Usability Testing: Its Application in Both Product Development and System Implementation.

    PubMed

    Kushniruk, Andre; Borycki, Elizabeth

    2017-01-01

    In recent years there has been considerable discussion around the need for certification and regulation of healthcare information technology (IT). In particular, the usability of the products being developed needs to be evaluated. This has included the application of standards designed to ensure the process of system development is user-centered and takes usability into consideration while a product is being developed. In addition to this, in healthcare, organizations in the United States and Europe have also addressed the need and requirement for product certification. However, despite these efforts there are continued reports of unusable and unsafe implementations. In this paper we discuss the need to not only include (and require) usability testing in the one-time development process of health IT products (such as EHRs), but we also argue for the need to additionally develop specific usability standards and requirements for usability testing during the implementation of vendor products (i.e. post product development) in healthcare settings. It is further argued that health IT products that may have been certified regarding their development process will still require application of usability testing in the process of implementing them in real hospital settings in order to ensure usability and safety. This is needed in order to ensure that the final result of both product development and implementation processes take into account and apply the latest usability principles and methods.

  9. A Pedagogical Approach toward Teaching an Information Systems Student How to Conduct a Web Usability Study for an Honors Project: A Case Study

    ERIC Educational Resources Information Center

    Jesse, Gayle

    2013-01-01

    The purpose of this paper is to provide educators with a course model and pedagogy to teach a computer information systems usability course. This paper offers a case study based on an honors student project titled "Web Usability: Phases of Developing an Interactive Event Database." Each individual phase--creating a prototype along with…

  10. A review of privacy and usability issues in mobile health systems: Role of external factors.

    PubMed

    Katusiime, Jane; Pinkwart, Niels

    2017-10-01

    The increased penetration of mobile devices has created opportunities in the health sector and led to emerging of mobile health systems. As much as the mobile health systems have registered tremendous progress, they have been faced with privacy and usability issues. Due to the sensitivity of health information, there is an ethical need to equip mobile health systems with adequate privacy measures. However, these systems should also be useable by the intended users. Even though many researchers are working on solutions, the issues still persist. External factors such as cultural differences have also contributed to the issues, yet they have been under researched. In this article, we conduct a systematic literature review of 22 articles, categorize and present privacy and usability issues and possible solutions. We then discuss the relevance and implications of external factors to the findings on privacy and usability. We end with recommendations to address these external factors.

  11. Exploring user experience and technology acceptance for a fall prevention system: results from a randomized clinical trial and a living lab.

    PubMed

    Vaziri, Daryoush D; Aal, Konstantin; Ogonowski, Corinna; Von Rekowski, Thomas; Kroll, Michael; Marston, Hannah R; Poveda, Rakel; Gschwind, Yves J; Delbaere, Kim; Wieching, Rainer; Wulf, Volker

    2016-01-01

    Falls are common in older adults and can result in serious injuries. Due to demographic changes, falls and related healthcare costs are likely to increase over the next years. Participation and motivation of older adults in fall prevention measures remain a challenge. The iStoppFalls project developed an information and communication technology (ICT)-based system for older adults to use at home in order to reduce common fall risk factors such as impaired balance and muscle weakness. The system aims at increasing older adults' motivation to participate in ICT-based fall prevention measures. This article reports on usability, user-experience and user-acceptance aspects affecting the use of the iStoppFalls system by older adults. In the course of a 16-week international multicenter study, 153 community-dwelling older adults aged 65+ participated in the iStoppFalls randomized controlled trial, of which half used the system in their home to exercise and assess their risk of falling. During the study, 60 participants completed questionnaires regarding the usability, user experience and user acceptance of the iStoppFalls system. Usability was measured with the System Usability Scale (SUS). For user experience the Physical Activity Enjoyment Scale (PACES) was applied. User acceptance was assessed with the Dynamic Acceptance Model for the Re-evaluation of Technologies (DART). To collect more detailed data on usability, user experience and user acceptance, additional qualitative interviews and observations were conducted with participants. Participants evaluated the usability of the system with an overall score of 62 (Standard Deviation, SD 15.58) out of 100, which suggests good usability. Most users enjoyed the iStoppFalls games and assessments, as shown by the overall PACES score of 31 (SD 8.03). With a score of 0.87 (SD 0.26), user acceptance results showed that participants accepted the iStoppFalls system for use in their own home. Interview data suggested that certain factors such as motivation, complexity or graphical design were different for gender and age. The results suggest that the iStoppFalls system has good usability, user experience and user acceptance. It will be important to take these along with factors such as motivation, gender and age into consideration when designing and further developing ICT-based fall prevention systems.

  12. A Usability Case Study Using TREC and ZPRISE.

    ERIC Educational Resources Information Center

    Downey, Laura L.; Tice, Dawn M.

    1999-01-01

    Examines the challenges involved in conducting an informal usability case study based on the introduction of a new information-retrieval system to experienced users. Identifies problems users were having with TREC (Text Retrieval Conference) and examines the usability of the new ZPRISE interface. (Author/LRW)

  13. A Method for Automated Detection of Usability Problems from Client User Interface Events

    PubMed Central

    Saadawi, Gilan M.; Legowski, Elizabeth; Medvedeva, Olga; Chavan, Girish; Crowley, Rebecca S.

    2005-01-01

    Think-aloud usability analysis provides extremely useful data but is very time-consuming and expensive to perform because of the extensive manual video analysis that is required. We describe a simple method for automated detection of usability problems from client user interface events for a developing medical intelligent tutoring system. The method incorporates (1) an agent-based method for communication that funnels all interface events and system responses to a centralized database, (2) a simple schema for representing interface events and higher order subgoals, and (3) an algorithm that reproduces the criteria used for manual coding of usability problems. A correction factor was empirically determining to account for the slower task performance of users when thinking aloud. We tested the validity of the method by simultaneously identifying usability problems using TAU and manually computing them from stored interface event data using the proposed algorithm. All usability problems that did not rely on verbal utterances were detectable with the proposed method. PMID:16779121

  14. Usability: a critical success factor for managing change in the clinical info-structure.

    PubMed

    Kay, S

    2005-06-01

    There can be no doubt that the clinical info-structure is being significantly enriched with the deployment of new systems throughout the health sector. From a technological perspective, the initial emphasis has been mainly on functionality and only latterly on the usability of these clinical information systems. However, the large scale and rapid pace of the changes being wrought in the health sector will have a major impact on clinicians and patients, not least in how they interact with the technology. Therefore, it is not only hardware and software but people-ware, too, that needs to be actively managed; not simply a one-off functional specification but an ongoing, complex relationship. Usability is the human factor that encompasses the ethical, educational, and evaluative aspects of design. There is also a strong case for regarding usability of clinical information systems as a key critical success factor for the management of change within the health-care domain. In particular, the relationship between usability, and education and training is examined.

  15. 39 CFR 501.15 - Computerized Meter Resetting System.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15...

  16. VoIP Accessibility: A Usability Study of Voice over Internet Protocol (VoIP) Systems and A Survey of VoIP Users with Vision Loss

    ERIC Educational Resources Information Center

    Packer, Jaclyn; Reuschel, William

    2018-01-01

    Introduction: Accessibility of Voice over Internet Protocol (VoIP) systems was tested with a hands-on usability study and an online survey of VoIP users who are visually impaired. The survey examined the importance of common VoIP features, and both methods assessed difficulty in using those features. Methods: The usability test included four paid…

  17. Initial Usability and Feasibility Evaluation of a Personal Health Record-Based Self-Management System for Older Adults.

    PubMed

    Sheehan, Barbara; Lucero, Robert J

    2015-01-01

    Electronic personal health record-based (ePHR-based) self-management systems can improve patient engagement and have an impact on health outcomes. In order to realize the benefits of these systems, there is a need to develop and evaluate heath information technology from the same theoretical underpinnings. Using an innovative usability approach based in human-centered distributed information design (HCDID), we tested an ePHR-based falls-prevention self-management system-Self-Assessment via a Personal Health Record (i.e., SAPHeR)-designed using HCDID principles in a laboratory. And we later evaluated SAPHeR's use by community-dwelling older adults at home. The innovative approach used in this study supported the analysis of four components: tasks, users, representations, and functions. Tasks were easily learned and features such as text-associated images facilitated task completion. Task performance times were slow, however user satisfaction was high. Nearly seven out of every ten features desired by design participants were evaluated in our usability testing of the SAPHeR system. The in vivo evaluation suggests that older adults could improve their confidence in performing indoor and outdoor activities after using the SAPHeR system. We have applied an innovative consumer-usability evaluation. Our approach addresses the limitations of other usability testing methods that do not utilize consistent theoretically based methods for designing and testing technology. We have successfully demonstrated the utility of testing consumer technology use across multiple components (i.e., task, user, representational, functional) to evaluate the usefulness, usability, and satisfaction of an ePHR-based self-management system.

  18. Evaluating Usability of Radiology Information Systems in Hospitals of Tabriz University of Medical Sciences.

    PubMed

    Rezaei-Hachesu, Peyman; Pesianian, Esmaeil; Mohammadian, Mohsen

    2016-02-01

    Radiology information system (RIS) in order to reduce workload and improve the quality of services must be well-designed. Heuristic evaluation is one of the methods that understand usability problems with the least time, cost and resources. The aim of present study is to evaluate the usability of RISs in hospitals. This is a cross-sectional descriptive study (2015) that uses heuristic evaluation method to evaluate the usability of RIS used in 3 hospitals of Tabriz city. The data are collected using a standard checklist based on 13 principles of Nielsen Heuristic evaluation method. Usability of RISs was investigated based on the number of components observed from Nielsen principles and problems of usability based on the number of non-observed components as well as non-existent or unrecognizable components. by evaluation of RISs in each of the hospitals 1, 2 and 3, total numbers of observed components were obtained as 173, 202 and 196, respectively. It was concluded that the usability of RISs in the studied population, on average and with observing 190 components of the 291 components related to the 13 principles of Nielsen is 65.41 %. Furthermore, problems of usability were obtained as 26.35%. The established and visible nature of some components such as response time of application, visual feedbacks, colors, view and design and arrangement of software objects cause more attention to these components as principal components in designing UI software. Also, incorrect analysis before system design leads to a lack of attention to secondary needs like Help software and security issues.

  19. Usability Study of a Wireless Monitoring System among Alzheimer's Disease Elderly Population

    PubMed Central

    Avvenuti, Marco

    2014-01-01

    Healthcare technologies are slowly entering into our daily lives, replacing old devices and techniques with newer intelligent ones. Although they are meant to help people, the reaction and willingness to use such new devices by the people can be unexpected, especially among the elderly. We conducted a usability study of a fall monitoring system in a long-term nursing home. The subjects were the elderly with advanced Alzheimer's disease. The study presented here highlights some of the challenges faced in the use of wearable devices and the lessons learned. The results gave us useful insights, leading to ergonomics and aesthetics modifications to our wearable systems that significantly improved their usability and acceptance. New evaluating metrics were designed for the performance evaluation of usability and acceptability. PMID:24963289

  20. A Modified User-Oriented Heuristic Evaluation of a Mobile Health System for Diabetes Self-management Support

    PubMed Central

    Georgsson, Mattias; Staggers, Nancy; Weir, Charlene

    2016-01-01

    Mobile health platforms offer significant opportunities for improving diabetic self-care, but only if adequate usability exists. Expert evaluations such as heuristic evaluation can provide distinct usability information about systems. The purpose of this study was to complete a usability evaluation of a mobile health system for diabetes patients using a modified heuristic evaluation technique of (1) dual-domain experts (healthcare professionals, usability experts), (2) validated scenarios and user tasks related to patients’ self-care, and (3) in-depth severity factor ratings. Experts identified 129 usability problems with 274 heuristic violations for the system. The categories Consistency and Standards dominated at 24.1% (n = 66), followed by Match Between System and Real World at 22.3% (n = 61). Average severity ratings across system views were 2.8 (of 4), with 9.3% (n = 12) rated as catastrophic and 53.5% (n = 69) as major. The large volume of violations with severe ratings indicated clear priorities for redesign. The modified heuristic approach allowed evaluators to identify unique and important issues, including ones related to self-management and patient safety. This article provides a template for one type of expert evaluation adding to the informaticists’ toolbox when needing to conduct a fast, resource-efficient and user-oriented heuristic evaluation. PMID:26657618

  1. A Modified User-Oriented Heuristic Evaluation of a Mobile Health System for Diabetes Self-management Support.

    PubMed

    Georgsson, Mattias; Staggers, Nancy; Weir, Charlene

    2016-02-01

    Mobile health platforms offer significant opportunities for improving diabetic self-care, but only if adequate usability exists. Expert evaluations such as heuristic evaluation can provide distinct usability information about systems. The purpose of this study was to complete a usability evaluation of a mobile health system for diabetes patients using a modified heuristic evaluation technique of (1) dual-domain experts (healthcare professionals, usability experts), (2) validated scenarios and user tasks related to patients' self-care, and (3) in-depth severity factor ratings. Experts identified 129 usability problems with 274 heuristic violations for the system. The categories Consistency and Standards dominated at 24.1% (n = 66), followed by Match Between System and Real World at 22.3% (n = 61). Average severity ratings across system views were 2.8 (of 4), with 9.3% (n = 12) rated as catastrophic and 53.5% (n = 69) as major. The large volume of violations with severe ratings indicated clear priorities for redesign. The modified heuristic approach allowed evaluators to identify unique and important issues, including ones related to self-management and patient safety. This article provides a template for one type of expert evaluation adding to the informaticists' toolbox when needing to conduct a fast, resource-efficient and user-oriented heuristic evaluation.

  2. The design and evaluation of an activity monitoring user interface for people with stroke.

    PubMed

    Hart, Phil; Bierwirth, Rebekah; Fulk, George; Sazonov, Edward

    2014-01-01

    Usability is an important topic in the field of telerehabilitation research. Older users with disabilities in particular, present age-related and disability-related challenges that should be accommodated for in the design of a user interface for a telerehabilitation system. This paper describes the design, implementation, and assessment of a telerehabilitation system user interface that tries to maximize usability for an elderly user who has experienced a stroke. An Internet-connected Nintendo(®) Wii™ gaming system is selected as a hardware platform, and a server and website are implemented to process and display the feedback information. The usability of the interface is assessed with a trial consisting of 18 subjects: 10 healthy Doctor of Physical Therapy students and 8 people with a stroke. Results show similar levels of usability and high satisfaction with the gaming system interface from both groups of subjects.

  3. Evidence-based Heuristics for Evaluating Demands on eHealth Literacy and Usability in a Mobile Consumer Health Application.

    PubMed

    Monkman, Helen; Griffith, Janessa; Kushniruk, Andre W

    2015-01-01

    Heuristic evaluations have proven to be valuable for identifying usability issues in systems. Commonly used sets of heuritics exist; however, they may not always be the most suitable, given the specific goal of the analysis. One such example is seeking to evaluate the demands on eHealth literacy and usability of consumer health information systems. In this study, eight essential heuristics and three optional heuristics subsumed from the evidence on eHealth/health literacy and usability were tested for their utility in assessing a mobile blood pressure tracking application (app). This evaluation revealed a variety of ways the design of the app could both benefit and impede users with limited eHealth literacy. This study demonstrated the utility of a low-cost, single evaluation approach for identifying both eHealth literacy and usability issues based on existing evidence in the literature.

  4. VRUSE--a computerised diagnostic tool: for usability evaluation of virtual/synthetic environment systems.

    PubMed

    Kalawsky, R S

    1999-02-01

    A special questionnaire (VRUSE) has been designed to measure the usability of a VR system according to the attitude and perception of its users. Important aspects of VR systems were carefully derived to produce key usability factors for the questionnaire. Unlike questionnaires designed for generic interfaces VRUSE is specifically designed to cater for evaluating virtual environments, being a diagnostic tool providing a wealth of information about a user's viewpoint of the interface. VRUSE can be used to great effect with other evaluation techniques to pinpoint problematical areas of a VR interface. Other applications include bench-marking of competitor VR systems.

  5. 'Televaluation' of clinical information systems: an integrative approach to assessing Web-based systems.

    PubMed

    Kushniruk, A W; Patel, C; Patel, V L; Cimino, J J

    2001-04-01

    The World Wide Web provides an unprecedented opportunity for widespread access to health-care applications by both patients and providers. The development of new methods for assessing the effectiveness and usability of these systems is becoming a critical issue. This paper describes the distance evaluation (i.e. 'televaluation') of emerging Web-based information technologies. In health informatics evaluation, there is a need for application of new ideas and methods from the fields of cognitive science and usability engineering. A framework is presented for conducting evaluations of health-care information technologies that integrates a number of methods, ranging from deployment of on-line questionnaires (and Web-based forms) to remote video-based usability testing of user interactions with clinical information systems. Examples illustrating application of these techniques are presented for the assessment of a patient clinical information system (PatCIS), as well as an evaluation of use of Web-based clinical guidelines. Issues in designing, prototyping and iteratively refining evaluation components are discussed, along with description of a 'virtual' usability laboratory.

  6. Usability testing of an mHealth device for swallowing therapy in head and neck cancer survivors.

    PubMed

    Constantinescu, Gabriela; Kuffel, Kristina; King, Ben; Hodgetts, William; Rieger, Jana

    2018-04-01

    The objective of this study was to conduct the first patient usability testing of a mobile health (mHealth) system for in-home swallowing therapy. Five participants with a history of head and neck cancer evaluated the mHealth system. After completing an in-application (app) tutorial with the clinician, participants were asked to independently complete five tasks: pair the device to the smartphone, place the device correctly, exercise, interpret progress displays, and close the system. Quantitative and qualitative methods were used to evaluate the effectiveness, efficiency, and satisfaction with the system. Critical changes to the app were found in three of the tasks, resulting in recommendations for the next iteration. These issues were related to ease of Bluetooth pairing, placement of device, and interpretation of statistics. Usability testing with patients identified issues that were essential to address prior to implementing the mHealth system in subsequent clinical trials. Of the usability methods used, video observation (synced screen capture with videoed gestures) revealed the most information.

  7. Usability Evaluation and Implementation of a Health Information Technology Dashboard of Evidence-Based Quality Indicators.

    PubMed

    Schall, Mark Christopher; Cullen, Laura; Pennathur, Priyadarshini; Chen, Howard; Burrell, Keith; Matthews, Grace

    2017-06-01

    Health information technology dashboards that integrate evidence-based quality indicators can efficiently and accurately display patient risk information to promote early intervention and improve overall quality of patient care. We describe the process of developing, evaluating, and implementing a dashboard designed to promote quality care through display of evidence-based quality indicators within an electronic health record. Clinician feedback was sought throughout the process. Usability evaluations were provided by three nurse pairs and one physician from medical-surgical areas. Task completion times, error rates, and ratings of system usability were collected to compare the use of quality indicators displayed on the dashboard to the indicators displayed in a conventional electronic health record across eight experimental scenarios. Participants rated the dashboard as "highly usable" following System Usability Scale (mean, 87.5 [SD, 9.6]) and Poststudy System Usability Questionnaire (mean, 1.7 [SD, 0.5]) criteria. Use of the dashboard led to reduced task completion times and error rates in comparison to the conventional electronic health record for quality indicator-related tasks. Clinician responses to the dashboard display capabilities were positive, and a multifaceted implementation plan has been used. Results suggest application of the dashboard in the care environment may lead to improved patient care.

  8. Evaluation of Usability Utilizing Markov Models

    ERIC Educational Resources Information Center

    Penedo, Janaina Rodrigues; Diniz, Morganna; Ferreira, Simone Bacellar Leal; Silveira, Denis S.; Capra, Eliane

    2012-01-01

    Purpose: The purpose of this paper is to analyze the usability of a remote learning system in its initial development phase, using a quantitative usability evaluation method through Markov models. Design/methodology/approach: The paper opted for an exploratory study. The data of interest of the research correspond to the possible accesses of users…

  9. Grappling with Distributed Usability: A Cultural-Historical Examination of Documentation Genres Over Four Decades.

    ERIC Educational Resources Information Center

    Spinuzzi, Clay

    2001-01-01

    Describes and illustrates a distributed approach to usability (envisioning usability across the genres, practices, uses, and goals of a given activity) using a four-decade examination of a traffic accident location and analysis system. Uses the theoretical framework of "genre ecologies" to show how communities of users interact with…

  10. The effect of user's perceived presence and promotion focus on usability for interacting in virtual environments.

    PubMed

    Sun, Huey-Min; Li, Shang-Phone; Zhu, Yu-Qian; Hsiao, Bo

    2015-09-01

    Technological advance in human-computer interaction has attracted increasing research attention, especially in the field of virtual reality (VR). Prior research has focused on examining the effects of VR on various outcomes, for example, learning and health. However, which factors affect the final outcomes? That is, what kind of VR system design will achieve higher usability? This question remains largely. Furthermore, when we look at VR system deployment from a human-computer interaction (HCI) lens, does user's attitude play a role in achieving the final outcome? This study aims to understand the effect of immersion and involvement, as well as users' regulatory focus on usability for a somatosensory VR learning system. This study hypothesized that regulatory focus and presence can effectively enhance user's perceived usability. Survey data from 78 students in Taiwan indicated that promotion focus is positively related to user's perceived efficiency, whereas involvement and promotion focus are positively related to user's perceived effectiveness. Promotion focus also predicts user satisfaction and overall usability perception. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  11. An Assessment-for-Learning System in Mathematics for Individuals with Visual Impairments

    ERIC Educational Resources Information Center

    Hansen, Eric G.; Shute, Valerie J.; Landau, Steven

    2010-01-01

    This study examined the usability of an assessment-for-learning (AfL) system that provides audio-tactile graphics for algebra content (geometric sequences) for individuals with visual impairments--two who are blind and two with low vision. It found that the system is generally usable as a mathematics AfL system. (Contains 4 tables.)

  12. Usability: Human Research Program - Space Human Factors and Habitability

    NASA Technical Reports Server (NTRS)

    Sandor, Aniko; Holden, Kritina L.

    2009-01-01

    The Usability project addresses the need for research in the area of metrics and methodologies used in hardware and software usability testing in order to define quantifiable and verifiable usability requirements. A usability test is a human-in-the-loop evaluation where a participant works through a realistic set of representative tasks using the hardware/software under investigation. The purpose of this research is to define metrics and methodologies for measuring and verifying usability in the aerospace domain in accordance with FY09 focus on errors, consistency, and mobility/maneuverability. Usability metrics must be predictive of success with the interfaces, must be easy to obtain and/or calculate, and must meet the intent of current Human Systems Integration Requirements (HSIR). Methodologies must work within the constraints of the aerospace domain, be cost and time efficient, and be able to be applied without extensive specialized training.

  13. Review of health information technology usability study methodologies

    PubMed Central

    Bakken, Suzanne

    2011-01-01

    Usability factors are a major obstacle to health information technology (IT) adoption. The purpose of this paper is to review and categorize health IT usability study methods and to provide practical guidance on health IT usability evaluation. 2025 references were initially retrieved from the Medline database from 2003 to 2009 that evaluated health IT used by clinicians. Titles and abstracts were first reviewed for inclusion. Full-text articles were then examined to identify final eligibility studies. 629 studies were categorized into the five stages of an integrated usability specification and evaluation framework that was based on a usability model and the system development life cycle (SDLC)-associated stages of evaluation. Theoretical and methodological aspects of 319 studies were extracted in greater detail and studies that focused on system validation (SDLC stage 2) were not assessed further. The number of studies by stage was: stage 1, task-based or user–task interaction, n=42; stage 2, system–task interaction, n=310; stage 3, user–task–system interaction, n=69; stage 4, user–task–system–environment interaction, n=54; and stage 5, user–task–system–environment interaction in routine use, n=199. The studies applied a variety of quantitative and qualitative approaches. Methodological issues included lack of theoretical framework/model, lack of details regarding qualitative study approaches, single evaluation focus, environmental factors not evaluated in the early stages, and guideline adherence as the primary outcome for decision support system evaluations. Based on the findings, a three-level stratified view of health IT usability evaluation is proposed and methodological guidance is offered based upon the type of interaction that is of primary interest in the evaluation. PMID:21828224

  14. Design of Remote Heat-Meter System Based on Trusted Technology

    NASA Astrophysics Data System (ADS)

    Yu, Changgeng; Lai, Liping

    2018-03-01

    This article presents a proposal of a heat meter and remote meter reading system for the disadvantages of the hackers very easily using eavesdropping, tampering, replay attack of traditional remote meter reading system. The system selects trusted technology such as, the identity authentication, integrity verifying, and data protection. By the experiments, it is proved that the remote meter reading system of the heat meter can be used to verify the feasibility of the technology, and verify the practicability and operability of data protection technology.

  15. Task-specific usability requirements of electronic medical records systems: Lessons learned from a national survey of end-users.

    PubMed

    Farzandipour, Mehrdad; Meidani, Zahra; Riazi, Hossein; Sadeqi Jabali, Monireh

    2018-09-01

    There are various approaches to evaluating the usability of electronic medical record (EMR) systems. User perspectives are an integral part of evaluation. Usability evaluations efficiently and effectively contribute to user-centered design and supports tasks and increase user satisfaction. This study determined the main usability requirements for EMRs by means of an end-user survey. A mixed-method strategy was conducted in three phases. A qualitative approach was employed to collect and formulate EMR usability requirements using the focus group method and the modified Delphi technique. Classic Delphi technique was used to evaluate the proposed requirements among 380 end-users in Iran. The final list of EMR usability requirements was verified and included 163 requirements divided into nine groups. The highest rates of end-user agreement relate to EMR visual clarity (3.65 ± 0.61), fault tolerance (3.58 ± 0.56), and suitability for learning (3.55 ± 0.54). The lowest end-user agreement was for auditory presentation (3.18 ± 0.69). The highest and lowest agreement among end-users was for visual clarity and auditory presentation by EMRs, respectively. This suggests that user priorities in determination of EMR usability and their understanding of the importance of the types of individual tasks and context characteristics differ.

  16. Integrating Visual Mnemonics and Input Feedback With Passphrases to Improve the Usability and Security of Digital Authentication.

    PubMed

    Juang, Kevin; Greenstein, Joel

    2018-04-01

    We developed a new authentication system based on passphrases instead of passwords. Our new system incorporates a user-generated mnemonic picture displayed during login, definition tooltips, error correction to reduce typographical errors, a decoy-based input masking technique, and random passphrase generation using either a specialized wordlist or a sentence template. Passphrases exhibit a greater level of security than traditional passwords, but their wider adoption has been hindered by human factors issues. Our assertion is that the added features of our system work particularly well with passphrases and help address these shortcomings. We conducted a study to evaluate our new system with a customized 1,450-word list and our new system with a 6-word sentence structure against the control conditions of a user-created passphrase of at least 24 characters and a system-generated passphrase using a 10,326-word list. Fifty participants completed two sessions so that we could measure the usability and security of the authentication schemes. With the new system conditions, memorability was improved, and security was equivalent to or better than the control conditions. Usability and overall ratings also favored the new system conditions over the control conditions. Our research presents a new authentication system using innovative techniques that improve on the usability and security of existing password and passphrase authentication systems. In computer security, drastic changes should never happen overnight, but we recommend that our contributions be incorporated into current authentication systems to help facilitate a transition from passwords to usable passphrases.

  17. 14 CFR 135.159 - Equipment requirements: Carrying passengers under VFR at night or under VFR over-the-top conditions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... a third attitude instrument system usable through flight attitudes of 360 degrees of pitch-and-roll... chapter. (2) Helicopters with a third attitude instrument system usable through flight attitudes of ±80...

  18. Assessing the Potential Use of Eye-Tracking Triangulation for Evaluating the Usability of an Online Diabetes Exercise System.

    PubMed

    Schaarup, Clara; Hartvigsen, Gunnar; Larsen, Lars Bo; Tan, Zheng-Hua; Årsand, Eirik; Hejlesen, Ole Kristian

    2015-01-01

    The Online Diabetes Exercise System was developed to motivate people with Type 2 diabetes to do a 25 minutes low-volume high-intensity interval training program. In a previous multi-method evaluation of the system, several usability issues were identified and corrected. Despite the thorough testing, it was unclear whether all usability problems had been identified using the multi-method evaluation. Our hypothesis was that adding the eye-tracking triangulation to the multi-method evaluation would increase the accuracy and completeness when testing the usability of the system. The study design was an Eye-tracking Triangulation; conventional eye-tracking with predefined tasks followed by The Post-Experience Eye-Tracked Protocol (PEEP). Six Areas of Interests were the basis for the PEEP-session. The eye-tracking triangulation gave objective and subjective results, which are believed to be highly relevant for designing, implementing, evaluating and optimizing systems in the field of health informatics. Future work should include testing the method on a larger and more representative group of users and apply the method on different system types.

  19. Digital casts in orthodontics: a comparison of 4 software systems.

    PubMed

    Westerlund, Anna; Tancredi, Weronika; Ransjö, Maria; Bresin, Andrea; Psonis, Spyros; Torgersson, Olof

    2015-04-01

    The introduction of digital cast models is inevitable in the otherwise digitized everyday life of orthodontics. The introduction of this new technology, however, is not straightforward, and selecting an appropriate system can be difficult. The aim of the study was to compare 4 orthodontic digital software systems regarding service, features, and usability. Information regarding service offered by the companies was obtained from questionnaires and Web sites. The features of each software system were collected by exploring the user manuals and the software programs. Replicas of pretreatment casts were sent to Cadent (OrthoCAD; Cadent, Carlstadt, NJ), OthoLab (O3DM; OrthoLab, Poznan, Poland), OrthoProof (DigiModel; OrthoProof, Nieuwegein, The Netherlands), and 3Shape (OrthoAnalyzer; 3Shape, Copenhagen, Denmark). The usability of the programs was assessed by experts in interaction design and usability using the "enhanced cognitive walkthrough" method: 4 tasks were defined and performed by a group of domain experts while they were observed by usability experts. The services provided by the companies were similar. Regarding the features, all 4 systems were able to perform basic measurements; however, not all provided the peer assessment rating index or the American Board of Orthodontics analysis, simulation of the treatment with braces, or digital articulation of the casts. All systems demonstrated weaknesses in usability. However, OrthoCAD and 03DM were considered to be easier to learn for first-time users. In general, the usability of these programs was poor and needs to be further developed. Hands-on training supervised by the program experts is recommended for beginners. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  20. Usability Evaluation of the Student Centered e-Learning Environment

    ERIC Educational Resources Information Center

    Junus, Inas Sofiyah; Santoso, Harry Budi; Isal, R. Yugo K.; Utomo, Andika Yudha

    2015-01-01

    Student Centered e-Learning Environment (SCeLE) has substantial roles to support learning activities at Faculty of Computer Science, Universitas Indonesia (Fasilkom UI). Although it has been utilized for about 10 years, the usability aspect of SCeLE as an e-Learning system has not been evaluated. Therefore, the usability aspects of SCeLE Fasilkom…

  1. Usability Assessment of Educational Software by Students: Case of "?Pón-Ìm?`" in Osun State, Nigeria

    ERIC Educational Resources Information Center

    Tijani, O. K.

    2016-01-01

    This study investigated usability of educational software: case of "?pón-Ìm?`" in Osun state, Nigeria. Specifically, the study investigated influences of gender and school locations on students' assessment of "?pón-Ìm?`" Technology Enhanced Learning System (OTELS) based on selected usability parameters. 701 students were…

  2. A Usability Study of Users' Perceptions toward a Multimedia Computer-Assisted Learning Tool for Neuroanatomy

    ERIC Educational Resources Information Center

    Gould, Douglas J.; Terrell, Mark A.; Fleming, Jo

    2008-01-01

    This usability study evaluated users' perceptions of a multimedia prototype for a new e-learning tool: Anatomy of the Central Nervous System: A Multimedia Course. Usability testing is a collection of formative evaluation methods that inform the developmental design of e-learning tools to maximize user acceptance, satisfaction, and adoption.…

  3. A health literacy and usability heuristic evaluation of a mobile consumer health application.

    PubMed

    Monkman, Helen; Kushniruk, Andre

    2013-01-01

    Usability and health literacy are two critical factors in the design and evaluation of consumer health information systems. However, methods for evaluating these two factors in conjunction remain limited. This study adapted a set of existing guidelines for the design of consumer health Web sites into evidence-based evaluation heuristics tailored specifically for mobile consumer health applications. In order to test the approach, a mobile consumer health application (app) was then evaluated using these heuristics. In addition to revealing ways to improve the usability of the system, this analysis identified opportunities to augment the content to make it more understandable by users with limited health literacy. This study successfully demonstrated the utility of converting existing design guidelines into heuristics for the evaluation of usability and health literacy. The heuristics generated could be applied for assessing and revising other existing consumer health information systems.

  4. User-centered development and testing of a monitoring system that provides feedback regarding physical functioning to elderly people

    PubMed Central

    Vermeulen, Joan; Neyens, Jacques CL; Spreeuwenberg, Marieke D; van Rossum, Erik; Sipers, Walther; Habets, Herbert; Hewson, David J; de Witte, Luc P

    2013-01-01

    Purpose To involve elderly people during the development of a mobile interface of a monitoring system that provides feedback to them regarding changes in physical functioning and to test the system in a pilot study. Methods and participants The iterative user-centered development process consisted of the following phases: (1) selection of user representatives; (2) analysis of users and their context; (3) identification of user requirements; (4) development of the interface; and (5) evaluation of the interface in the lab. Subsequently, the monitoring and feedback system was tested in a pilot study by five patients who were recruited via a geriatric outpatient clinic. Participants used a bathroom scale to monitor weight and balance, and a mobile phone to monitor physical activity on a daily basis for six weeks. Personalized feedback was provided via the interface of the mobile phone. Usability was evaluated on a scale from 1 to 7 using a modified version of the Post-Study System Usability Questionnaire (PSSUQ); higher scores indicated better usability. Interviews were conducted to gain insight into the experiences of the participants with the system. Results The developed interface uses colors, emoticons, and written and/or spoken text messages to provide daily feedback regarding (changes in) weight, balance, and physical activity. The participants rated the usability of the monitoring and feedback system with a mean score of 5.2 (standard deviation 0.90) on the modified PSSUQ. The interviews revealed that most participants liked using the system and appreciated that it signaled changes in their physical functioning. However, usability was negatively influenced by a few technical errors. Conclusion Involvement of elderly users during the development process resulted in an interface with good usability. However, the technical functioning of the monitoring system needs to be optimized before it can be used to support elderly people in their self-management. PMID:24039407

  5. A Usability Survey of a Contents-Based Video Retrieval System by Combining Digital Video and an Electronic Bulletin Board

    ERIC Educational Resources Information Center

    Haga, Hirohide; Kaneda, Shigeo

    2005-01-01

    This article describes the survey of the usability of a novel content-based video retrieval system. This system combines video streaming and an electronic bulletin board system (BBS). Comments submitted to the BBS are used to index video data. Following the development of the prototype system an experimental survey with ten subjects was performed.…

  6. Ten Demands of Improved Usability in eHealth and Some Progress - Co-Creation by Health and Social Care Professionals.

    PubMed

    Scandurra, Isabella; Liljequist, David

    2016-01-01

    Current healthcare organizations often do not accomplish the intended effects of their eHealth systems due to inadequate usability. Commissioned by the Swedish Ministry of Health and Social Affairs, the usability of current eHealth systems in Swedish health and social care has been analysed from the perspective of their professionals. The objective of the study was to report on current problems, potential solutions as well as to relate these to research in relevant areas. Using a participatory approach, nine workshops were held where health informatics researchers guided staff from different care organizations, representatives of the national associations of health and social care professionals and the national eHealth system vendor organization. This paper presents ten demands that Swedish health and social care professionals find imperative to prioritize. The study emphasizes that development of eHealth systems must be integrated into the care practice improvement process and iteratively evaluated regarding usability.

  7. Enhancing patient safety and quality of care by improving the usability of electronic health record systems: recommendations from AMIA.

    PubMed

    Middleton, Blackford; Bloomrosen, Meryl; Dente, Mark A; Hashmat, Bill; Koppel, Ross; Overhage, J Marc; Payne, Thomas H; Rosenbloom, S Trent; Weaver, Charlotte; Zhang, Jiajie

    2013-06-01

    In response to mounting evidence that use of electronic medical record systems may cause unintended consequences, and even patient harm, the AMIA Board of Directors convened a Task Force on Usability to examine evidence from the literature and make recommendations. This task force was composed of representatives from both academic settings and vendors of electronic health record (EHR) systems. After a careful review of the literature and of vendor experiences with EHR design and implementation, the task force developed 10 recommendations in four areas: (1) human factors health information technology (IT) research, (2) health IT policy, (3) industry recommendations, and (4) recommendations for the clinician end-user of EHR software. These AMIA recommendations are intended to stimulate informed debate, provide a plan to increase understanding of the impact of usability on the effective use of health IT, and lead to safer and higher quality care with the adoption of useful and usable EHR systems.

  8. Enhancing patient safety and quality of care by improving the usability of electronic health record systems: recommendations from AMIA

    PubMed Central

    Middleton, Blackford; Bloomrosen, Meryl; Dente, Mark A; Hashmat, Bill; Koppel, Ross; Overhage, J Marc; Payne, Thomas H; Rosenbloom, S Trent; Weaver, Charlotte; Zhang, Jiajie

    2013-01-01

    In response to mounting evidence that use of electronic medical record systems may cause unintended consequences, and even patient harm, the AMIA Board of Directors convened a Task Force on Usability to examine evidence from the literature and make recommendations. This task force was composed of representatives from both academic settings and vendors of electronic health record (EHR) systems. After a careful review of the literature and of vendor experiences with EHR design and implementation, the task force developed 10 recommendations in four areas: (1) human factors health information technology (IT) research, (2) health IT policy, (3) industry recommendations, and (4) recommendations for the clinician end-user of EHR software. These AMIA recommendations are intended to stimulate informed debate, provide a plan to increase understanding of the impact of usability on the effective use of health IT, and lead to safer and higher quality care with the adoption of useful and usable EHR systems. PMID:23355463

  9. Exploring the Usability of Mobile Apps Supporting Radiologists' Training in Diagnostic Decision Making.

    PubMed

    Kim, Min Soon; Aro, Michael R; Lage, Kraig J; Ingalls, Kevin L; Sindhwani, Vivek; Markey, Mia K

    2016-03-01

    The objective of this study was to conduct a usability evaluation of mobile apps for supporting education and training in radiologic diagnostic decision-making processes. Of 381 mobile apps available at two major stores (Google Play and iTunes), eight iOS apps were selected for laboratory-based usability tests. Six staff radiologists completed eight app-specific task sets, using a think-aloud strategy. The triangular methods approach included quantitative performance measures, System Usability Scale (SUS), and qualitative thematic analysis using heuristic usability principles of usability issues. Overall, radiologists achieved higher than 70% success, with favorable SUS scores, in completing the tasks for seven of the eight apps. However, task success rate and SUS score had a weak relation (r = 0.23), indicating that the perceived usability may not reflect the holistic usability of the app. Task analysis and self-report revealed 108 usability issues, which were condensed to 55 unique issues and categorized by nine usability themes and mapped to ten usability heuristics. Nonintuitive functionality (eg, nonintuitive or misleading labels) was the most frequent theme observed, leading to inefficient navigation. These usability findings were consistent with the 13 improvements the radiologists suggested. This study demonstrates the feasibility of usability evaluation of radiology mobile apps and suggests potential improvements in the development of radiology mobile apps. This study also suggests that proficiency with mobile devices may not be equivalent to being an expert user, proficient in using the apps. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Ten factors to consider when developing usability scenarios and tasks for health information technology.

    PubMed

    Russ, Alissa L; Saleem, Jason J

    2018-02-01

    The quality of usability testing is highly dependent upon the associated usability scenarios. To promote usability testing as part of electronic health record (EHR) certification, the Office of the National Coordinator (ONC) for Health Information Technology requires that vendors test specific capabilities of EHRs with clinical end-users and report their usability testing process - including the test scenarios used - along with the results. The ONC outlines basic expectations for usability testing, but there is little guidance in usability texts or scientific literature on how to develop usability scenarios for healthcare applications. The objective of this article is to outline key factors to consider when developing usability scenarios and tasks to evaluate computer-interface based health information technologies. To achieve this goal, we draw upon a decade of our experience conducting usability tests with a variety of healthcare applications and a wide range of end-users, to include healthcare professionals as well as patients. We discuss 10 key factors that influence scenario development: objectives of usability testing; roles of end-user(s); target performance goals; evaluation time constraints; clinical focus; fidelity; scenario-related bias and confounders; embedded probes; minimize risks to end-users; and healthcare related outcome measures. For each factor, we present an illustrative example. This article is intended to aid usability researchers and practitioners in their efforts to advance health information technologies. The article provides broad guidance on usability scenario development and can be applied to a wide range of clinical information systems and applications. Published by Elsevier Inc.

  11. Usability flaws of medication-related alerting functions: A systematic qualitative review.

    PubMed

    Marcilly, Romaric; Ammenwerth, Elske; Vasseur, Francis; Roehrer, Erin; Beuscart-Zéphir, Marie-Catherine

    2015-06-01

    Medication-related alerting functions may include usability flaws that limit their optimal use. A first step on the way to preventing usability flaws is to understand the characteristics of these usability flaws. This systematic qualitative review aims to analyze the type of usability flaws found in medication-related alerting functions. Papers were searched via PubMed, Scopus and Ergonomics Abstracts databases, along with references lists. Paper selection, data extraction and data analysis was performed by two to three Human Factors experts. Meaningful semantic units representing instances of usability flaws were the main data extracted. They were analyzed through qualitative methods: categorization following general usability heuristics and through an inductive process for the flaws specific to medication-related alerting functions. From the 6380 papers initially identified, 26 met all eligibility criteria. The analysis of the papers identified a total of 168 instances of usability flaws that could be classified into 13 categories of usability flaws representing either violations of general usability principles (i.e. they could be found in any system, e.g. guidance and workload issues) or infractions specific to medication-related alerting functions. The latter refer to issues of low signal-to-noise ratio, incomplete content of alerts, transparency, presentation mode and timing, missing alert features, tasks and control distribution. The list of 168 instances of usability flaws of medication-related alerting functions provides a source of knowledge for checking the usability of medication-related alerting functions during their design and evaluation process and ultimately constructs evidence-based usability design principles for these functions. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Usability problems do not heal by themselves: National survey on physicians' experiences with EHRs in Finland.

    PubMed

    Kaipio, Johanna; Lääveri, Tinja; Hyppönen, Hannele; Vainiomäki, Suvi; Reponen, Jarmo; Kushniruk, Andre; Borycki, Elizabeth; Vänskä, Jukka

    2017-01-01

    Survey studies of health information systems use tend to focus on availability of functionalities, adoption and intensity of use. Usability surveys have not been systematically conducted by any healthcare professional groups on a national scale on a repeated basis. This paper presents results from two cross-sectional surveys of physicians' experiences with the usability of currently used EHR systems in Finland. The research questions were: To what extent has the overall situation improved between 2010 and 2014? What differences are there between healthcare sectors? In the spring of 2014, a survey was conducted in Finland using a questionnaire that measures usability and respondents' user experiences with electronic health record (EHR) systems. The survey was targeted to physicians who were actively doing clinical work. Twenty-four usability-related statements, that were identical in 2010 and 2014, were analysed from the survey. The respondents were also asked to give an overall rating of the EHR system they used. The study data comprised responses from 3081 physicians from the year 2014 and from 3223 physicians in the year 2010, who were using the nine most commonly used EHR system brands in Finland. Physicians' assessments of the usability of their EHR system remain as critical as they were in 2010. On a scale from 1 ('fail') to 7 ('excellent') the average of overall ratings of their principally used EHR systems varied from 3.2 to 4.4 in 2014 (and in 2010 from 2.5 to 4.3). The results show some improvements in the following EHR functionalities and characteristics: summary view of patient's health status, prevention of errors associated with medication ordering, patient's medication list as well as support for collaboration and information exchange between the physician and the nurses. Even so, support for cross-organizational collaboration between physicians and for physician-patient collaboration were still considered inadequate. Satisfaction with technical features had not improved in four years. The results show marked differences between the EHR system brands as well as between healthcare sectors (private sector, public hospitals, primary healthcare). Compared to responses from the public sector, physicians working in the private sector were more satisfied with their EHR systems with regards to statements about user interface characteristics and support for routine tasks. Overall, the study findings are similar to our previous study conducted in 2010. Surveys about the usability of EHR systems are needed to monitor their development at regional and national levels. To our knowledge, this study is the first national eHealth observatory questionnaire that focuses on usability and is used to monitor the long-term development of EHRs. The results do not show notable improvements in physician's ratings for their EHRs between the years 2010 and 2014 in Finland. Instead, the results indicate the existence of serious problems and deficiencies which considerably hinder the efficiency of EHR use and physician's routine work. The survey results call for considerable amount of development work in order to achieve the expected benefits of EHR systems and to avoid technology-induced errors which may endanger patient safety. The findings of repeated surveys can be used to inform healthcare providers, decision makers and politicians about the current state of EHR usability and differences between brands as well as for improvements of EHR usability. This survey will be repeated in 2017 and there is a plan to include other healthcare professional groups in future surveys. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  13. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    PubMed

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests that the reader is usable among and can benefit a wide group of potential users, including in POC contexts. Generally, the methodology of this study demonstrates the importance of testing these types of systems with potential users and exemplifies how iterative design processes can be employed by multidisciplinary research teams to produce compelling technological solutions. ©Jess Hohenstein, Dakota O'Dell, Elizabeth L Murnane, Zhengda Lu, David Erickson, Geri Gay. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 21.11.2017.

  14. Example of a Human Factors Engineering approach to a medication administration work system: potential impact on patient safety.

    PubMed

    Beuscart-Zéphir, Marie-Catherine; Pelayo, Sylvia; Bernonville, Stéphanie

    2010-04-01

    The objectives of this paper are: In this approach, the implementation of such a complex IT solution is considered a major redesign of the work system. The paper describes the Human Factor (HF) tasks embedded in the project lifecycle: (1) analysis and modelling of the current work system and usability assessment of the medication CPOE solution; (2) HF recommendations for work re-design and usability recommendations for IT system re-engineering both aiming at a safer and more efficient work situation. Standard ethnographic methods were used to support the analysis of the current work system and work situations, coupled with cognitive task analysis methods and documents review. Usability inspection (heuristic evaluation) and both in-lab (simulated tasks) and on-site (real tasks) usability tests were performed for the evaluation of the CPOE candidate. Adapted software engineering models were used in combination with usual textual descriptions, tasks models and mock-ups to support the recommendations for work and product re-design. The analysis of the work situations identified different work organisations and procedures across the hospital's departments. The most important differences concerned the doctor-nurse communications and cooperation modes and the procedures for preparing and administering the medications. The assessment of the medication CPOE functions uncovered a number of usability problems including severe ones leading to impossible to detect or to catch errors. Models of the actual and possible distribution of tasks and roles were used to support decision making in the work design process. The results of the usability assessment were translated into requirements to support the necessary re-engineering of the IT application. The HFE approach to medication CPOE efficiently identifies and distinguishes currently unsafe or uncomfortable work situations that could obviously benefit from an IT solution from other work situations incorporating efficient work procedures that might be impaired by the implementation of the CPOE. In this context, a careful redesign of the work situation and of the entire work system is necessary to actually benefit from the installation of the product in terms of patient safety and human performances. In parallel, a usability assessment of the product to be implemented is mandatory to identify potentially dangerous usability flaws and to fix them before the installation. (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  15. APRN Usability Testing of a Tailored Computer-Mediated Health Communication Program

    PubMed Central

    Lin, Carolyn A.; Neafsey, Patricia J.; Anderson, Elizabeth

    2010-01-01

    This study tested the usability of a touch-screen enabled “Personal Education Program” (PEP) with Advanced Practice Registered Nurses (APRN). The PEP is designed to enhance medication adherence and reduce adverse self-medication behaviors in older adults with hypertension. An iterative research process was employed, which involved the use of: (1) pre-trial focus groups to guide the design of system information architecture, (2) two different cycles of think-aloud trials to test the software interface, and (3) post-trial focus groups to gather feedback on the think-aloud studies. Results from this iterative usability testing process were utilized to systematically modify and improve the three PEP prototype versions—the pilot, Prototype-1 and Prototype-2. Findings contrasting the two separate think-aloud trials showed that APRN users rated the PEP system usability, system information and system-use satisfaction at a moderately high level between trials. In addition, errors using the interface were reduced by 76 percent and the interface time was reduced by 18.5 percent between the two trials. The usability testing processes employed in this study ensured an interface design adapted to APRNs' needs and preferences to allow them to effectively utilize the computer-mediated health-communication technology in a clinical setting. PMID:19940619

  16. 77 FR 8217 - Evaluating the Usability of Electronic Health Record (EHR) Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ... interface design guidelines for EHRs. Manufacturers interested in participating in this research will be... the usability of health information technology (HIT) systems. NIST research is designed to: (1... develop performance-oriented user interface design guidelines for EHRs, and a framework for assessing the...

  17. Usability of light-emitting diodes in precision approach path indicator systems by individuals with marginal color vision.

    DOT National Transportation Integrated Search

    2014-05-01

    To save energy, the FAA is planning to convert from incandescent lights to light-emitting diodes (LEDs) in : precision approach path indicator (PAPI) systems. Preliminary work on the usability of LEDs by color vision-waivered pilots (Bullough, Skinne...

  18. Promise Fulfilled? An EBSCO Discovery Service Usability Study

    ERIC Educational Resources Information Center

    Williams, Sarah C.; Foster, Anita K.

    2011-01-01

    Discovery tools are the next phase of library search systems. Illinois State University's Milner Library implemented EBSCO Discovery Service in August 2010. The authors conducted usability studies on the system in the fall of 2010. The aims of the study were twofold: first, to determine how Milner users set about using the system in order to…

  19. Usability Testing of Two Ambulatory EHR Navigators.

    PubMed

    Hultman, Gretchen; Marquard, Jenna; Arsoniadis, Elliot; Mink, Pamela; Rizvi, Rubina; Ramer, Tim; Khairat, Saif; Fickau, Keri; Melton, Genevieve B

    2016-01-01

    Despite widespread electronic health record (EHR) adoption, poor EHR system usability continues to be a significant barrier to effective system use for end users. One key to addressing usability problems is to employ user testing and user-centered design. To understand if redesigning an EHR-based navigation tool with clinician input improved user performance and satisfaction. A usability evaluation was conducted to compare two versions of a redesigned ambulatory navigator. Participants completed tasks for five patient cases using the navigators, while employing a think-aloud protocol. The tasks were based on Meaningful Use (MU) requirements. The version of navigator did not affect perceived workload, and time to complete tasks was longer in the redesigned navigator. A relatively small portion of navigator content was used to complete the MU-related tasks, though navigation patterns were highly variable across participants for both navigators. Preferences for EHR navigation structures appeared to be individualized. This study demonstrates the importance of EHR usability assessments to evaluate group and individual performance of different interfaces and preferences for each design.

  20. Usability and accessibility in consumer health informatics current trends and future challenges.

    PubMed

    Goldberg, Larry; Lide, Bettijoyce; Lowry, Svetlana; Massett, Holly A; O'Connell, Trisha; Preece, Jennifer; Quesenbery, Whitney; Shneiderman, Ben

    2011-05-01

    It is a truism that, for innovative eHealth systems to have true value and impact, they must first and foremost be usable and accessible by clinicians, consumers, and other stakeholders. In this paper, current trends and future challenges in the usability and accessibility of consumer health informatics will be described. Consumer expectations of their healthcare providers and healthcare records in this new era of consumer-directed care will be explored, and innovative visualizations, assistive technologies, and other ways that healthcare information is currently being provided and/or shared will be described. Challenges for ensuring the usability of current and future systems will also be discussed. An innovative model for conducting systematic, timely, user-centered research on consumer-facing websites at the National Cancer Institute (NCI) and the ongoing efforts at the National Institute of Standards and Technology (NIST) to promote health information technology (HIT) usability standards and evaluation criteria will also be presented. Copyright © 2011 American Journal of Preventive Medicine. All rights reserved.

  1. Evaluation of a BCMA’s Electronic Medication Administration Record

    PubMed Central

    Staggers, Nancy; Iribarren, Sarah; Guo, Jia-Wen; Weir, Charlene

    2015-01-01

    Barcode medication administration (BCMA) systems can reduce medication errors, but sociotechnical issues are quite common. Although crucial to nurses’ work, few usability evaluations are available for electronic medication administration record screens (eMARs). The purpose of this research was to identify current usability problems in the VA’s eMAR/BCMA system and explore how these might impact nurses’ situation awareness. Three expert evaluators used 10 tasks/elements, heuristic evaluation techniques and explored potential impacts using a situation awareness perspective. The results yielded 99 usability problems categorized into 440 heuristic violations with the largest volume in the category of Match with the Real World. Fifteen usability issues were rated as catastrophic with the Administer/Chart medications task having the most. Situational awareness was impacted at all levels, especially at Level 2, Comprehension. Usability problems point to important areas for improvement because these issues have the potential to impact nurses’ situation awareness, “at a glance” information, nurse productivity and patient safety. PMID:25601936

  2. Discovering How Students Search a University Web Site: A Comparative Usability Case Study for PC and Mobile Devices

    ERIC Educational Resources Information Center

    Sengel, Erhan

    2014-01-01

    This study aims to investigate the usability level of web site of a university by observing 10 participants who are required to complete 11 tasks, which have been defined by the researchers before to gather data about effectiveness, efficiency and satisfaction. System Usability Scale was used to collect data about satisfaction. The research…

  3. Developing and Validation a Usability Evaluation Tools for Distance Education Websites: Persian Version

    ERIC Educational Resources Information Center

    Hafezi, Soheila; Farahi, Ahmad; Mehri, Soheil Najafi; Mahmoodi, Hosein

    2010-01-01

    The web is playing a central role in distance education. The word "usability" is usually synonymous with functionality of the system for the user. Also, usability of a website is defined as something that can be used by a specific group of people to carry out specific objectives in an effective way, with efficiency and satisfaction.…

  4. Facilitating Energy Savings through Enhanced Usability of Thermostats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meier, Alan; Aragon, Cecilia; Peffer, Therese

    2011-05-23

    Residential thermostats play a key role in controlling heating and cooling systems. Occupants often find the controls of programmable thermostats confusing, sometimes leading to higher heating consumption than when the buildings are controlled manually. A high degree of usability is vital to a programmable thermostat's effectiveness because, unlike a more efficient heating system, occupants must engage in specific actions after installation to obtain energy savings. We developed a procedure for measuring the usability of thermostats and tested this methodology with 31 subjects on five thermostats. The procedure requires first identifying representative tasks associated with the device and then testing themore » subjects ability to accomplish those tasks. The procedure was able to demonstrate the subjects wide ability to accomplish tasks and the influence of a device's usability on success rates. A metric based on the time to accomplish the tasks and the fraction of subjects actually completing the tasks captured the key aspects of each thermostat's usability. The procedure was recently adopted by the Energy Star Program for its thermostat specification. The approach appears suitable for quantifying usability of controls in other products, such as heat pump water heaters and commercial lighting.« less

  5. An appraisal of published usability evaluations of electronic health records via systematic review.

    PubMed

    Ellsworth, Marc A; Dziadzko, Mikhail; O'Horo, John C; Farrell, Ann M; Zhang, Jiajie; Herasevich, Vitaly

    2017-01-01

    In this systematic review, we aimed to evaluate methodological and reporting trends present in the current literature by investigating published usability studies of electronic health records (EHRs). A literature search was conducted for articles published through January 2015 using MEDLINE (Ovid), EMBASE, Scopus, and Web of Science, supplemented by citation and reference list reviews. Studies were included if they tested the usability of hospital and clinic EHR systems in the inpatient, outpatient, emergency department, or operating room setting. A total of 4848 references were identified for title and abstract screening. Full text screening was performed for 197 articles, with 120 meeting the criteria for study inclusion. A review of the literature demonstrates a paucity of quality published studies describing scientifically valid and reproducible usability evaluations at various stages of EHR system development. A lack of formal and standardized reporting of EHR usability evaluation results is a major contributor to this knowledge gap, and efforts to improve this deficiency will be one step of moving the field of usability engineering forward. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Development of the Telehealth Usability Questionnaire (TUQ).

    PubMed

    Parmanto, Bambang; Lewis, Allen Nelson; Graham, Kristin M; Bertolet, Marnie H

    2016-01-01

    Current telehealth usability questionnaires are designed primarily for older technologies, where telehealth interaction is conducted over dedicated videoconferencing applications. However, telehealth services are increasingly conducted over computer-based systems that rely on commercial software and a user supplied computer interface. Therefore, a usability questionnaire that addresses the changes in telehealth service delivery and technology is needed. The Telehealth Usability Questionnaire (TUQ) was developed to evaluate the usability of telehealth implementation and services. This paper addresses: (1) the need for a new measure of telehealth usability, (2) the development of the TUQ, (3) intended uses for the TUQ, and (4) the reliability of the TUQ. Analyses indicate that the TUQ is a solid, robust, and versatile measure that can be used to measure the quality of the computer-based user interface and the quality of the telehealth interaction and services.

  7. Conceptual design for a user-friendly adaptive optics system at Lick Observatory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bissinger, H.D.; Olivier, S.; Max, C.

    1996-03-08

    In this paper, we present a conceptual design for a general-purpose adaptive optics system, usable with all Cassegrain facility instruments on the 3 meter Shane telescope at the University of California`s Lick Observatory located on Mt. Hamilton near San Jose, California. The overall design goal for this system is to take the sodium-layer laser guide star adaptive optics technology out of the demonstration stage and to build a user-friendly astronomical tool. The emphasis will be on ease of calibration, improved stability and operational simplicity in order to allow the system to be run routinely by observatory staff. A prototype adaptivemore » optics system and a 20 watt sodium-layer laser guide star system have already been built at Lawrence Livermore National Laboratory for use at Lick Observatory. The design presented in this paper is for a next- generation adaptive optics system that extends the capabilities of the prototype system into the visible with more degrees of freedom. When coupled with a laser guide star system that is upgraded to a power matching the new adaptive optics system, the combined system will produce diffraction-limited images for near-IR cameras. Atmospheric correction at wavelengths of 0.6-1 mm will significantly increase the throughput of the most heavily used facility instrument at Lick, the Kast Spectrograph, and will allow it to operate with smaller slit widths and deeper limiting magnitudes. 8 refs., 2 figs.« less

  8. Implant technology and usability.

    PubMed

    Meadows, Paul M

    2008-08-01

    Implanted electrical stimulation technology has changed greatly in the roughly five decades of its existence. Many factors determine the viability of the technology and whether the systems and products developed ultimately go on to help the target patient population. This article describes the successful introduction of an implanted system and the challenges to implanted system development, acceptance, and usability of these systems by the patient and clinical communities.

  9. Developing an Android-Based Patient Decision Aid Based on Ottawa Standards for Patients After Kidney Transplant and Its Usability Evaluation.

    PubMed

    Zare Moayedi, Mahboobeh; Aslani, Azam; Fakhrahmad, Mostafa; Ezzatzadegan J, Shahrokh

    2018-01-01

    This study was conducted to develop an android based patient decision aid (PDA) as a self-care instrument for patients after kidney transplant and its usability evaluation. In this study, the systematic development process of Android-based self-care application for patients after kidney transplant based on Ottawa standard was included: scoping, assemble steering group, analysis of requirements, designing, develop of a prototype and system evaluation. The PDA is a self-triage system that will help early identification of risk symptoms in patients, and help manage them. System recommendations for risk signs are: Refer to the nearest hospital or healthcare center without delay, refer to the doctor and tell your doctor in the next visit. To identify patient care needs, a semi-structured interview with members of steering group, including patients and clinical experts, was conducted by the researchers. A prototype of the decision aid was made according to identified needs in the previous step. Finally, in order to evaluate its usability rate by using the System Usability Scale (SUS) questionnaire, it was used by exerts and patients. This study identified information needs, risk signs and steps that patients need to make appropriate decisions about them. The main capabilities of the decision aid are features such as reminders for appointment/test, time of taking medication, registration of symptoms, weight, blood pressure, body temperature, advising to patient in case of signs of risk, weight, blood pressure, body temperature and test results which were reported in the diagram. The mean score of system's usability evaluated by medical informatics specialists, clinicians, and patients were 88.33, 95, and 91. PDAs was usable and desirable from the point of view of medical informatics specialists, clinicians and patients.

  10. A novel computerized surgeon-machine interface for robot-assisted laser phonomicrosurgery.

    PubMed

    Mattos, Leonardo S; Deshpande, Nikhil; Barresi, Giacinto; Guastini, Luca; Peretti, Giorgio

    2014-08-01

    To introduce a novel computerized surgical system for improved usability, intuitiveness, accuracy, and controllability in robot-assisted laser phonomicrosurgery. Pilot technology assessment. The novel system was developed involving a newly designed motorized laser micromanipulator, a touch-screen display, and a graphics stylus. The system allows the control of a CO2 laser through interaction between the stylus and the live video of the surgical area. This empowers the stylus with the ability to have actual effect on the surgical site. Surgical enhancements afforded by this system were established through a pilot technology assessment using randomized trials comparing its performance with a state-of-the-art laser microsurgery system. Resident surgeons and medical students were chosen as subjects in performing sets of trajectory-following exercises. Image processing-based techniques were used for an objective performance assessment. A System Usability Scale-based questionnaire was used for the qualitative assessment. The computerized interface demonstrated superiority in usability, accuracy, and controllability over the state-of-the-art system. Significant ease of use and learning experienced by the subjects were demonstrated by the usability score assigned to the two compared interfaces: computerized interface = 83.96% versus state-of-the-art = 68.02%. The objective analysis showed a significant enhancement in accuracy and controllability: computerized interface = 90.02% versus state-of-the-art = 75.59%. The novel system significantly enhances the accuracy, usability, and controllability in laser phonomicrosurgery. The design provides an opportunity to improve the ergonomics and safety of current surgical setups. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  11. The use of think-aloud and instant data analysis in evaluation research: Exemplar and lessons learned.

    PubMed

    Joe, Jonathan; Chaudhuri, Shomir; Le, Thai; Thompson, Hilaire; Demiris, George

    2015-08-01

    While health information technologies have become increasingly popular, many have not been formally tested to ascertain their usability. Traditional rigorous methods take significant amounts of time and manpower to evaluate the usability of a system. In this paper, we evaluate the use of instant data analysis (IDA) as developed by Kjeldskov et al. to perform usability testing on a tool designed for older adults and caregivers. The IDA method is attractive because it takes significantly less time and manpower than the traditional usability testing methods. In this paper we demonstrate how IDA was used to evaluate usability of a multifunctional wellness tool, discuss study results and lessons learned while using this method. We also present findings from an extension of the method which allows the grouping of similar usability problems in an efficient manner. We found that the IDA method is a quick, relatively easy approach to identifying and ranking usability issues among health information technologies. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Getting a Technology-based Diabetes Intervention Ready for Primetime: A Review of Usability Testing Studies

    PubMed Central

    Lyles, Courtney R.; Sarkar, Urmimala; Osborn, Chandra Y.

    2014-01-01

    Consumer health technologies can educate patients about diabetes and support their self-management, yet usability evidence is rarely published even though it determines patient engagement, optimal benefit of any intervention, and an understanding of generalizability. Therefore, we conducted a narrative review of peer-reviewed articles published from 2009–2013 that tested the usability of a web- or mobile-delivered system/application designed to educate and support patients with diabetes. Overall, the 23 papers included in our review used mixed (n=11), descriptive quantitative (n=9), and qualitative methods (n=3) to assess usability, such as documenting which features performed as intended and how patients rated their experiences. More sophisticated usability evaluations combined several complementary approaches to elucidate more aspects of functionality. Future work pertaining to the design and evaluation of technology-delivered diabetes education/support interventions should aim to standardize the usability testing processes, and publish usability findings to inform interpretation of why an intervention succeeded or failed, and for whom. PMID:25173689

  13. Tree Testing of Hierarchical Menu Structures for Health Applications

    PubMed Central

    Le, Thai; Chaudhuri, Shomir; Chung, Jane; Thompson, Hilaire J; Demiris, George

    2014-01-01

    To address the need for greater evidence-based evaluation of Health Information Technology (HIT) systems we introduce a method of usability testing termed tree testing. In a tree test, participants are presented with an abstract hierarchical tree of the system taxonomy and asked to navigate through the tree in completing representative tasks. We apply tree testing to a commercially available health application, demonstrating a use case and providing a comparison with more traditional in-person usability testing methods. Online tree tests (N=54) and in-person usability tests (N=15) were conducted from August to September 2013. Tree testing provided a method to quantitatively evaluate the information structure of a system using various navigational metrics including completion time, task accuracy, and path length. The results of the analyses compared favorably to the results seen from the traditional usability test. Tree testing provides a flexible, evidence-based approach for researchers to evaluate the information structure of HITs. In addition, remote tree testing provides a quick, flexible, and high volume method of acquiring feedback in a structured format that allows for quantitative comparisons. With the diverse nature and often large quantities of health information available, addressing issues of terminology and concept classifications during the early development process of a health information system will improve navigation through the system and save future resources. Tree testing is a usability method that can be used to quickly and easily assess information hierarchy of health information systems. PMID:24582924

  14. Qualitative assessment of user experiences of a novel smart phone application designed to support flexible intensive insulin therapy in type 1 diabetes.

    PubMed

    Knight, Brigid A; McIntyre, H David; Hickman, Ingrid J; Noud, Marina

    2016-09-15

    Modern flexible multiple daily injection (MDI) therapy requires people with diabetes to manage complex mathematical calculations to determine insulin doses on a day to day basis. Automated bolus calculators assist with these calculations, add additional functionality to protect against hypoglycaemia and enhance the record keeping process, however uptake and use depends on the devices meeting the needs of the user. We aimed to obtain user feedback on the usability of a mobile phone bolus calculator application in adults with T1DM to inform future development of mobile phone diabetes support applications. Adults with T1DM who had previously received education in flexible MDI therapy were invited to participate. Eligible respondents attended app education and one month later participated in a focus group to provide feedback on the features of the app in relation to usability for patient-based flexible MDI and future app development. Seven adults participated in the app training and follow up interview. App features that support dose adjustment to reduce hypoglycaemia risk and features that enable greater efficiency in dose calculation, record keeping and report generation were highly valued. Adults who are self managing flexible MDI found the Rapidcalc mobile phone app to be a useful self-management tool and additional features to further improve usability, such as connectivity with BG meter and food databases, shortcut options to economise data entry and web based storage of data, were identified. Further work is needed to ascertain specific features and benefit for those with lower health literacy.

  15. Usability Testing of a National Substance Use Screening Tool Embedded in Electronic Health Records.

    PubMed

    Press, Anne; DeStio, Catherine; McCullagh, Lauren; Kapoor, Sandeep; Morley, Jeanne; Conigliaro, Joseph

    2016-07-08

    Screening, brief intervention, and referral to treatment (SBIRT) is currently being implemented into health systems nationally via paper and electronic methods. The purpose of this study was to evaluate the integration of an electronic SBIRT tool into an existing paper-based SBIRT clinical workflow in a patient-centered medical home. Usability testing was conducted in an academic ambulatory clinic. Two rounds of usability testing were done with medical office assistants (MOAs) using a paper and electronic version of the SBIRT tool, with two and four participants, respectively. Qualitative and quantitative data was analyzed to determine the impact of both tools on clinical workflow. A second round of usability testing was done with the revised electronic version and compared with the first version. Personal workflow barriers cited in the first round of testing were that the electronic health record (EHR) tool was disruptive to patient's visits. In Round 2 of testing, MOAs reported favoring the electronic version due to improved layout and the inclusion of an alert system embedded in the EHR. For example, using the system usability scale (SUS), MOAs reported a grade "1" for the statement, "I would like to use this system frequently" during the first round of testing but a "5" during the second round of analysis. The importance of testing usability of various mediums of tools used in health care screening is highlighted by the findings of this study. In the first round of testing, the electronic tool was reported as less user friendly, being difficult to navigate, and time consuming. Many issues faced in the first generation of the tool were improved in the second generation after usability was evaluated. This study demonstrates how usability testing of an electronic SBRIT tool can help to identify challenges that can impact clinical workflow. However, a limitation of this study was the small sample size of MOAs that participated. The results may have been biased to Northwell Health workers' perceptions of the SBIRT tool and their specific clinical workflow.

  16. Integration Of Launch Vehicle Simulation/Analysis Tools And Lunar Cargo Lander Design. Part 2/2

    NASA Technical Reports Server (NTRS)

    DeJean, George Brian; Shiue, Yeu-Sheng Paul; King, Jeffrey

    2005-01-01

    Part 2, which will be discussed in this report, will discuss the development of a Lunar Cargo Lander (unmanned launch vehicle) that will transport usable payload from Trans- Lunar Injection to the moon. The Delta IV-Heavy was originally used to transport the Lunar Cargo Lander to TLI, but other launch vehicles have been studied. In order to uncover how much payload is possible to land on the moon, research was needed in order to design the sub-systems of the spacecraft. The report will discuss and compare the use of a hypergolic and cryogenic system for its main propulsion system. The guidance, navigation, control, telecommunications, thermal, propulsion, structure, mechanisms, landing gear, command, data handling, and electrical power sub-systems were designed by scaling off other flown orbiters and moon landers. Once all data was collected, an excel spreadsheet was created to accurately calculate the usable payload that will land on the moon along with detailed mass and volume estimating relations. As designed, The Lunar Cargo Lander can plant 5,400 lbm of usable payload on the moon using a hypergolic system and 7,400 lbm of usable payload on the moon using a cryogenic system.

  17. Usability Evaluation at the Point-of-Care: A Method to Identify User Information Needs in CPOE Applications

    PubMed Central

    Washburn, Jeff; Fiol, Guilherme Del; Rocha, Roberto A.

    2006-01-01

    Point of care usability evaluation may help identify information needs that occur during the process of providing care. We describe the process of using usability-specific recording software to record Computerized Physician Order Entry (CPOE) ordering sessions on admitted adult and pediatric patients at two urban tertiary hospitals in the Intermountain Healthcare system of hospitals. PMID:17238756

  18. An investigation of the efficacy of collaborative virtual reality systems for moderated remote usability testing.

    PubMed

    Chalil Madathil, Kapil; Greenstein, Joel S

    2017-11-01

    Collaborative virtual reality-based systems have integrated high fidelity voice-based communication, immersive audio and screen-sharing tools into virtual environments. Such three-dimensional collaborative virtual environments can mirror the collaboration among usability test participants and facilitators when they are physically collocated, potentially enabling moderated usability tests to be conducted effectively when the facilitator and participant are located in different places. We developed a virtual collaborative three-dimensional remote moderated usability testing laboratory and employed it in a controlled study to evaluate the effectiveness of moderated usability testing in a collaborative virtual reality-based environment with two other moderated usability testing methods: the traditional lab approach and Cisco WebEx, a web-based conferencing and screen sharing approach. Using a mixed methods experimental design, 36 test participants and 12 test facilitators were asked to complete representative tasks on a simulated online shopping website. The dependent variables included the time taken to complete the tasks; the usability defects identified and their severity; and the subjective ratings on the workload index, presence and satisfaction questionnaires. Remote moderated usability testing methodology using a collaborative virtual reality system performed similarly in terms of the total number of defects identified, the number of high severity defects identified and the time taken to complete the tasks with the other two methodologies. The overall workload experienced by the test participants and facilitators was the least with the traditional lab condition. No significant differences were identified for the workload experienced with the virtual reality and the WebEx conditions. However, test participants experienced greater involvement and a more immersive experience in the virtual environment than in the WebEx condition. The ratings for the virtual environment condition were not significantly different from those for the traditional lab condition. The results of this study suggest that participants were productive and enjoyed the virtual lab condition, indicating the potential of a virtual world based approach as an alternative to conventional approaches for synchronous usability testing. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Automatic remote-integration metering center. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Philippidis, P.A.; Weinreb, M.; de Gil, B.F.

    1988-11-01

    The report documents a multi-phase program for the development and demonstration of a unique automatic and remote metering system. The system consists of a solid-state meter module to provide electrical consumption data, tamper detection, and load control functions; a central master station to interrogate the meter modules for their data and also to transmit load control signals; and a data display module to be accessible to tenants wishing to obtain their meter readings. The system has the capability to measure and allocate demand and to process time of use rates. It also has a meter accuracy self-test feature. The systemmore » is suitable for both direct metering of multi-family buildings and the sub-metering of master-metered apartment buildings. In addition to describing the system, the report documents the results of a 371-point field trial at Scott Tower, a cooperative apartment building in the Bronx, New York.« less

  20. How Usability Testing Resulted in Improvements to Ground Collision Software for General Aviation: Improved Ground Collision Avoidance System (IGCAS)

    NASA Technical Reports Server (NTRS)

    Lamarr, Michael; Chinske, Chris; Williams, Ethan; Law, Cameron; Skoog, Mark; Sorokowski, Paul

    2016-01-01

    The NASA improved Ground Collision Avoidance System (iGCAS) team conducted an onsite usability study at Experimental Aircraft Association (EAA) Air Venture in Oshkosh, Wisconsin from July 19 through July 26, 2015. EAA Air Venture had approximately 550,000 attendees from which the sample pool of pilots were selected. The objectives of this study were to assess the overall appropriateness and acceptability of iGCAS as a warning system for General Aviation aircraft, usability of the iGCAS displays and audio cues, test terrain avoidance characteristics, performance, functionality, pilot response time, and correlate terrain avoidance performance and pilot response time data.

  1. Complete energetic description of hydrokinetic turbine impact on flow channel dynamics

    NASA Astrophysics Data System (ADS)

    Brasseale, E.; Kawase, M.

    2016-02-01

    Energy budget analysis on tidal channels quantifies and demarcates the impacts of marine renewables on environmental fluid dynamics. Energy budget analysis assumes the change in total kinetic energy within a volume of fluid can be described by the work done by each force acting on the flow. In a numerically simulated channel, the balance between energy change and work done has been validated up to 5% error.The forces doing work on the flow include pressure, turbulent dissipation, and stress from the estuary floor. If hydrokinetic turbines are installed in an estuarine channel to convert tidal energy into usable power, the dynamics of the channel change. Turbines provide additional pressure work against the flow of the channel which will slow the current and lessen turbulent dissipation and bottom stress. These losses may negatively impact estuarine circulation, seafloor scour, and stratification.The environmental effects of turbine deployment have been quantified using a three dimensional, Reynolds-averaged, Navier-Stokes model of an idealized flow channel situated between the ocean and a large estuarine basin. The channel is five kilometers wide, twenty kilometers long and fifty meters deep, and resolved to a grid size of 10 meters by 10 meters by 1 meter. Tidal currents are simulated by an initial difference in sea surface height across the channel of 160 centimeters from the channel entrance to the channel exit. This creates a pressure gradient which drives flow through the channel. Tidal power turbines are represented as disks that force the channel in proportion to the strength of the current. Three tidal turbines twenty meters in diameters have been included in the model to simulate the impacts of a pilot scale test deployment.This study is the first to appreciate the energetic impact of marine renewables in a three dimensional model through the energy equation's constituent terms. This study provides groundwork for understanding and predicting the environmental impacts of marine renewables.

  2. Evaluation of a Telerehabilitation System for Community-Based Rehabilitation

    PubMed Central

    Schutte, Jamie; Gales, Sara; Filippone, Ashlee; Saptono, Andi; Parmanto, Bambang; McCue, Michael

    2012-01-01

    The use of web-based portals, while increasing in popularity in the fields of medicine and research, are rarely reported on in community-based rehabilitation programs. A program within the Pennsylvania Office of Vocational Rehabilitation’s Hiram G. Andrews Center, the Cognitive Skills Enhancement Program (CSEP), sought to enhance organization of program and participant information and communication between part- and full-time employees, supervisors and consultants. A telerehabilitation system was developed consisting of (1) a web-based portal to support a variety of clinical activities, and (2) the Versatile Integrated System for Telerehabilitation (VISYTER) video-conferencing system to support the collaboration and delivery of rehabilitation services remotely. This descriptive evaluation examines the usability of the telerehabilitation system incorporating both the portal and VISYTER. Telerehabilitation system users include CSEP staff members from three geographical locations and employed by two institutions. The IBM After-Scenario Questionnaire (ASQ) and Post-Study System Usability Questionnaire (PSSUQ), the Telehealth Usability Questionnaire (TUQ), and two demographic surveys were administered to gather both objective and subjective information. Results showed generally high levels of usability. Users commented that the telerehabilitation system improved communication, increased access to information, improved speed of completing tasks, and had an appealing interface. Areas where users would like to see improvements, including ease of accessing/editing documents and searching for information, are discussed. PMID:25945193

  3. Usability evaluation of the SMART application for youth with mTBI.

    PubMed

    Dexheimer, Judith W; Kurowski, Brad G; Anders, Shilo H; McClanahan, Nicole; Wade, Shari L; Babcock, Lynn

    2017-01-01

    There is a dearth of evidence-based treatments available to address the significant morbidity associated with mild traumatic brain injury (mTBI). To address this gap, we designed a novel user-friendly, web-based application. We describe the preliminary evaluation of feasibility and usability of the application to promote recovery following mTBI in youth, the Self-Monitoring Activity-Restriction and Relaxation Treatment (SMART). SMART incorporates real-time recommendations for individualized symptom management and activity restriction along with training in cognitive-behavioral coping strategies. We conducted a usability evaluation to assess and modify the SMART system prior to further study and deployment. Children ages 11-18 years presenting to the emergency department were recruited after symptoms resolved. Usability was assessed using a 60-min think-aloud protocol of teens and parents describing their interaction with the application. Upon completion of the tasks, each participant also completed the system usability scale (SUS). We performed tests with 4 parent/child dyads. The average age of the children was 13 years (standard deviation=1.8). The parents were an average of 41.5 years old (standard deviation=6.2). Research revealed that the participants were enthusiastic about the interactive portions of the tool particularly the video based sessions. Parents were concerned about the speed at which their child might move through the program and the children thought that the system required large amounts of reading. Based on user feedback, researchers modified SMART to include an audio file in every module and improved the system's aesthetic properties. The mean SUS score was 85, with high SUS scores (>68) indicating satisfactory usability. High initial usability and favorable user feedback provide a foundation for further iterative development and testing of the SMART application as a tool for managing recovery from concussion. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Development and user evaluation of a virtual rehabilitation system for wobble board balance training.

    PubMed

    Fitzgerald, Diarmaid; Trakarnratanakul, Nanthana; Dunne, Lucy; Smyth, Barry; Caulfield, Brian

    2008-01-01

    We have developed a prototype virtual reality-based balance training system using a single inertial orientation sensor attached to the upper surface of a wobble board. This input device has been interfaced with Neverball, an open source computer game to create the balance training platform. Users can exercise with the system by standing on the wobble board and tilting it in different directions to control an on-screen environment. We have also developed a customized instruction manual to use when setting up the system. To evaluate the usability our prototype system we undertook a user evaluation study with twelve healthy novice participants. Participants were required to assemble the system using an instruction manual and then perform balance exercises with the system. Following this period of exercise VRUSE, a usability evaluation questionnaire, was completed by participants. Results indicated a high level of usability in all categories evaluated.

  5. Evaluating the Usability of Pinchigator, a system for Navigating Virtual Worlds using Pinch Gloves

    NASA Technical Reports Server (NTRS)

    Hamilton, George S.; Brookman, Stephen; Dumas, Joseph D. II; Tilghman, Neal

    2003-01-01

    Appropriate design of two dimensional user interfaces (2D U/I) utilizing the well known WIMP (Window, Icon, Menu, Pointing device) environment for computer software is well studied and guidance can be found in several standards. Three-dimensional U/I design is not nearly so mature as 2D U/I, and standards bodies have not reached consensus on what makes a usable interface. This is especially true when the tools for interacting with the virtual environment may include stereo viewing, real time trackers and pinch gloves instead of just a mouse & keyboard. Over the last several years the authors have created a 3D U/I system dubbed Pinchigator for navigating virtual worlds based on the dVise dV/Mockup visualization software, Fakespace Pinch Gloves and Pohlemus trackers. The current work is to test the usability of the system on several virtual worlds, suggest improvements to increase Pinchigator s usability, and then to generalize about what was learned and how those lessons might be applied to improve other 3D U/I systems.

  6. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    PubMed

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  7. The Post-Dam System. Volume 5. Harvard Project Manager (HPM).

    DTIC Science & Technology

    1992-10-01

    cQllected and analyzed to determine structural integrity and usability. From this analysis, a repair schedule is developed. This is currently a time...information on mission-critical facility damage is collected and analyzed to determine structural integrity and usability. From this analysis, a repair...to determine repair strategies with an expert system, keep track of materials and equipment with a relational database management system, and

  8. Assessing and comparing the usability of Chinese EHRs used in two Peking University hospitals to EHRs used in the US: A method of RUA.

    PubMed

    Xu, Lufei; Wen, Dong; Zhang, Xingting; Lei, Jianbo

    2016-05-01

    The objective of this study was to investigate the usability level of Chinese hospital Electronic Health Records (EHRs) by assessing the completion times of EHRs for seven "meaningful use (MU)" relevant tasks conducted at two Chinese tertiary hospitals and comparing the results to those of relevant research conducted in US EHRs. Using Rapid Usability Assessment (RUA) developed by the National Center for Cognitive Informatics and Decision Making (NCCD), the usability of EHRs from two Peking University hospitals was assessed using a three-step Keystroke Level Model (KLM) in a laboratory environment. (1) The total EHR task completion time for 7 MU relevant test tasks showed no significant differences between the two Chinese EHRs and their US counterparts, in which the time for thinking was relatively large and comprised 35.6% of the total time. The time for the electronic physician order was the largest. (2) For specific tasks, the mean completion times of the 2 hospital EHR systems spent on recording, modifying and searching (RMS) the medication orders were similar to those for the RMS radioactive tests; the mean time spent on the RMS laboratory test orders were much less. (3) There were 85 usability problems identified in the 2 hospital EHR systems. In Chinese EHRs, a substantial amount of time is required to complete tasks relevant to MU targets and many preventable usability problems can be discovered. The task completion time of the 2 Chinese EHR systems was a little shorter than in the 5 reported US EHR systems, while the differences in smoking status and CPOE tasks were obvious; one main reason for these differences was the use of structured data entry. The efficiency of Chinese and US EHRs was not significantly different. The key to improving the efficiency of both systems lies in expediting the Computerized physician order entry (CPOE) task. Many usability problems can be identified using heuristic assessments and improved by corresponding actions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Effects of laryngoscope handle light source on the light intensity from disposable laryngoscope blades.

    PubMed

    Milne, A D; Brousseau, P A; Brousseau, C A

    2014-12-01

    A bench-top study was performed to assess the effects of different laryngoscope handles on the light intensity delivered from disposable metal or plastic laryngoscope blades. The light intensity from both the handle light sources themselves and the combined handle and laryngoscope blade sets was measured using a custom-designed testing system and light meter. Five samples of each disposable blade type were tested and compared with a standard re-usable stainless steel blade using three different handle/light sources (Vital Signs LED, Heine 2.5 V Xenon and 3.5 V Xenon). The light intensity delivered by the disposable blades ranged from 790 to 3846 lux for the different handle types. Overall, the 3.5 V Heine handle delivered the highest light output (p < 0.007) in comparison with the other handles. For the disposable blades, the overall light output was significantly higher from the plastic than the metal blades (p < 0.001). © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  10. Evaluation of Home Health Care Devices: Remote Usability Assessment.

    PubMed

    Kortum, Philip; Peres, S Camille

    2015-06-05

    An increasing amount of health care is now performed in a home setting, away from the hospital. While there is growing anecdotal evidence about the difficulty patients and caregivers have using increasingly complex health care devices in the home, there has been little systematic scientific study to quantify the global nature of home health care device usability in the field. Research has tended to focus on a handful of devices, making it difficult to gain a broad view of the usability of home-care devices in general. The objective of this paper is to describe a remote usability assessment method using the System Usability Scale (SUS), and to report on the usability of a broad range of health care devices using this metric. A total of 271 participants selected and rated up to 10 home health care devices of their choice using the SUS, which scores usability from 0 (unusable) to 100 (highly usable). Participants rated a total of 455 devices in their own home without an experimenter present. Usability scores ranged from 98 (oxygen masks) to 59 (home hormone test kits). An analysis conducted on devices that had at least 10 ratings showed that the effect of device on SUS scores was significant (P<.001), and that the usability of these devices was on the low end when compared with other commonly used items in the home, such as microwave ovens and telephones. A large database of usability scores for home health care devices collected using this remote methodology would be beneficial for physicians, patients, and their caregivers.

  11. Calibration and testing of selected portable flowmeters for use on large irrigation systems

    USGS Publications Warehouse

    Luckey, Richard R.; Heimes, Frederick J.; Gaggiani, Neville G.

    1980-01-01

    Existing methods for measuring discharge of irrigation systems in the High Plains region are not suitable to provide the pumpage data required by the High Plains Regional Aquifer System Analysis. Three portable flowmeters that might be suitable for obtaining fast and accurate discharge measure-ments on large irrigation systems were tested during 1979 under both laboratory and field conditions: propeller type gated-pipe meter, a Doppler meter, and a transient-time meter.The gated-pipe meter was found to be difficult to use and sensitive to particulate matter in the fluid. The Doppler meter, while easy to use, would not function suitably on steel pipe 6 inches or larger in diameter, or on aluminum pipe larger than 8 inches in diameter. The transient-time meter was more difficult to use than the other two meters; however, this instrument provided a high degree of accuracy and reliability under a variety of conditions. Of the three meters tested, only the transient-time meter was found to be suitable for providing reliable discharge measurements on the variety of irrigation systems used in the High Plains region.

  12. Momentum harvesting techniques for solar system travel

    NASA Technical Reports Server (NTRS)

    Willoughby, Alan J.

    1990-01-01

    Astronomers are lately estimating there are 400,000 Earth visiting asteroids larger than 100 meters in diameter. These asteroids are accessible sources of building materials, propellants, oxygen, water, and minerals which also constitute a huge momentum reserve, potentially usable for travel throughout the solar system. To use this momentum, these stealthy objects must be tracked and the extraction of the momentum wanted must be learned. Momentum harvesting by momentum transfer from asteroid to spacecraft, and by using the momentum of the extraterrestrial material to help deliver itself to the destination are discussed. A net and tether concept is the suggested means of asteroid capture, the basic momentum exchange process. The energy damping characteristics of the tether will determine the velocity mismatch that can be tolerated, and hence the amount of momentum that can be harvested per capture. As it plays out of its reel, drag on the tether steadily accelerates the spacecraft. A variety of concepts for riding and using the asteroid after capture are discussed. The hitchhiker uses momentum transfer only. The beachcomber, the caveman, the swinger, the prospector, and the rock wrecker also take advantage of raw asteroidal materials. The chemist and the hijacker go further, they process the asteroid into propellant. Or, an 'asteroid railway system' could evolve with each hijacked asteroid becoming a scheduled train. Travelers could board the space railway system assured that water, oxygen, and propellants await them.

  13. Get out of Fines Free: Recruiting Student Usability Testers via Fine Waivers

    ERIC Educational Resources Information Center

    Hockenberry, Benjamin; Blackburn, Kourtney

    2016-01-01

    St. John Fisher College's Lavery Library's Access Services and Systems departments began a pilot project in which students with overdue fines tested usability of library Web sites in exchange for fine waivers. Circulation staff promoted the program and redeemed fine waiver vouchers at the Checkout Desk, while Systems staff administered testing and…

  14. Usability of a Web-Based School Experience System: Opinions of IT Teachers and Teacher Candidates

    ERIC Educational Resources Information Center

    Genç, Zülfü

    2015-01-01

    With advances in information and communication technologies, the classical nature of educational institutions has changed. One innovative effort within teacher training is the Web-Based School Experience System (WBSES) developed by the researcher. In this study, the usability of an existing WBSES is evaluated from both teachers' (n = 13) and…

  15. Usability of a Battle Management System Under Simulated Vehicular Motion

    DTIC Science & Technology

    2012-10-01

    Figure 2, which is a commercial product designed to replicate racing car motions while playing computer games was used. The D-BOX is capable of three...7 3.2 Design ...standard usability issues such as interface design by using static BMS systems outside of vehicles (i.e. Command HQs or in the laboratory) (for example

  16. Usability Evaluation of an Unstructured Clinical Document Query Tool for Researchers.

    PubMed

    Hultman, Gretchen; McEwan, Reed; Pakhomov, Serguei; Lindemann, Elizabeth; Skube, Steven; Melton, Genevieve B

    2018-01-01

    Natural Language Processing - Patient Information Extraction for Researchers (NLP-PIER) was developed for clinical researchers for self-service Natural Language Processing (NLP) queries with clinical notes. This study was to conduct a user-centered analysis with clinical researchers to gain insight into NLP-PIER's usability and to gain an understanding of the needs of clinical researchers when using an application for searching clinical notes. Clinical researcher participants (n=11) completed tasks using the system's two existing search interfaces and completed a set of surveys and an exit interview. Quantitative data including time on task, task completion rate, and survey responses were collected. Interviews were analyzed qualitatively. Survey scores, time on task and task completion proportions varied widely. Qualitative analysis indicated that participants found the system to be useful and usable in specific projects. This study identified several usability challenges and our findings will guide the improvement of NLP-PIER 's interfaces.

  17. Procuring interoperability at the expense of usability: a case study of UK National Programme for IT assurance process.

    PubMed

    Krause, Paul; de Lusignan, Simon

    2010-01-01

    The allure of interoperable systems is that they should improve patient safety and make health services more efficient. The UK's National Programme for IT has made great strides in achieving interoperability; through linkage to a national electronic spine. However, there has been criticism of the usability of the applications in the clinical environment. Analysis of the procurement and assurance process to explore whether they predetermine usability. Processes separate developers from users, and test products against theoretical assurance models of use rather than simulate or pilot in a clinical environment. The current process appears to be effective for back office systems and high risk applications, but too inflexible for developing applications for the clinical setting. For clinical applications agile techniques are more appropriate. Usability testing should become an integrated part of the contractual process and be introduced earlier in the development process.

  18. Exploring the Role of Usability in the Software Process: A Study of Irish Software SMEs

    NASA Astrophysics Data System (ADS)

    O'Connor, Rory V.

    This paper explores the software processes and usability techniques used by Small and Medium Enterprises (SMEs) that develop web applications. The significance of this research is that it looks at development processes used by SMEs in order to assess to what degree usability is integrated into the process. This study seeks to gain an understanding into the level of awareness of usability within SMEs today and their commitment to usability in practice. The motivation for this research is to explore the current development processes used by SMEs in developing web applications and to understand how usability is represented in those processes. The background for this research is provided by the growth of the web application industry beyond informational web sites to more sophisticated applications delivering a broad range of functionality. This paper presents an analysis of the practices of several Irish SMEs that develop web applications through a series of case studies. With the focus on SMEs that develop web applications as Management Information Systems and not E-Commerce sites, informational sites, online communities or web portals. This study gathered data about the usability techniques practiced by these companies and their awareness of usability in the context of the software process in those SMEs. The contribution of this study is to further the understanding of the current role of usability within the software development processes of SMEs that develop web applications.

  19. How to Present Evidence-Based Usability Design Principles Dedicated to Medication-Related Alerting Systems to Designers and Evaluators? Results from a Workshop.

    PubMed

    Marcilly, Romaric; Monkman, Helen; Villumsen, Sidsel; Kaufman, David; Beuscart-Zephir, Marie-Catherine

    2016-01-01

    Medication alerting system use errors and lack of adoption are often attributed to usability issues. Previous work has used evidence from the literature to reveal usability principles specific to medication alerting systems and identify potential consequences of violating these principles. The current study sought to explore how best to convey these principles to designers and evaluators of these systems to facilitate their work. To this aim, a workshop with 19 participants was used to generate ideas and opinions on how to deliver these topic-specific design principles in a way that would be most helpful for them. Participants generated ideas for how (e.g., a collaborative, continuously updated forum) and what (e.g., illustrations, checklists, evidence sources and strength, consequences of violations) information is most useful to disseminate usability principles for medication alerting systems. Participants, especially designers, expressed desire to use these principles in practice and avoid previously documented mistakes and therefore make design and evaluation of these systems more effective and efficient. Those insights are discussed in terms of feasibility and logistical challenges to developing the proposed documentation). To move this work forward, a more collaborative approach of Human Factors specialists in medical informatics is necessary.

  20. Portable refrigerant charge meter and method for determining the actual refrigerant charge in HVAC systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Zhiming; Abdelaziz, Omar; LaClair, Tim L.

    A refrigerant charge meter and a method for determining the actual refrigerant charge in HVAC systems are described. The meter includes means for determining an optimum refrigerant charge from system subcooling and system component parameters. The meter also includes means for determining the ratio of the actual refrigerant charge to the optimum refrigerant charge. Finally, the meter includes means for determining the actual refrigerant charge from the optimum refrigerant charge and the ratio of the actual refrigerant charge to the optimum refrigerant charge.

  1. Addressing the Tension Between Strong Perimeter Control an Usability

    NASA Technical Reports Server (NTRS)

    Hinke, Thomas H.; Kolano, Paul Z.; Keller, Chris

    2006-01-01

    This paper describes a strong perimeter control system for a general purpose processing system, with the perimeter control system taking significant steps to address usability issues, thus mitigating the tension between strong perimeter protection and usability. A secure front end enforces two-factor authentication for all interactive access to an enclave that contains a large supercomputer and various associated systems, with each requiring their own authentication. Usability is addressed through a design in which the user has to perform two-factor authentication at the secure front end in order to gain access to the enclave, while an agent transparently performs public key authentication as needed to authenticate to specific systems within the enclave. The paper then describes a proxy system that allows users to transfer files into the enclave under script control, when the user is not present to perform two-factor authentication. This uses a pre-authorization approach based on public key technology, which is still strongly tied to both two-factor authentication and strict control over where files can be transferred on the target system. Finally the paper describes an approach to support network applications and systems such as grids or parallel file transfer protocols that require the use of many ports through the perimeter. The paper describes a least privilege approach that dynamically opens ports on a host-specific, if-authorized, as-needed, just-in-time basis.

  2. A feasibility study to determine if there is a market for automatic meter-reading devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hilberg, G.R.

    1996-08-01

    For many utilities the cost of manually reading meters is increasing due to personnel expenses and equipment costs. The current system of manual meters provides little ability for the utility to reduce costs. To reduce meter reading costs the utility must automate the manual system and reduce personnel expenses. A water utility in San Diego county was studied to calculate the cost of reading individual water meters. This would allow for the selective replacement of {open_quotes}high-cost{close_quotes} meters to quickly reduce meter-reading costs while limiting the necessary capital investments. As the {open_quotes}high-cost{close_quotes} meters are selectively replaced, a utility with a significantmore » difference in individual meter reading costs could save three to five dollars per meter per year. This study showed that the {open_quotes}high-cost{close_quotes} meters were six times more expensive to read than the average meter. Additionally, AMR systems increase the information available to consumers and to the utility on usage patterns and problems. The challenge was to cost effectively identify the {open_quotes}high-cost{close_quotes} meters. The costs to collect these data were less than $500.« less

  3. From Usability Testing to Clinical Simulations: Bringing Context into the Design and Evaluation of Usable and Safe Health Information Technologies. Contribution of the IMIA Human Factors Engineering for Healthcare Informatics Working Group.

    PubMed

    Kushniruk, A; Nohr, C; Jensen, S; Borycki, E M

    2013-01-01

    The objective of this paper is to explore human factors approaches to understanding the use of health information technology (HIT) by extending usability engineering approaches to include analysis of the impact of clinical context through use of clinical simulations. Methods discussed are considered on a continuum from traditional laboratory-based usability testing to clinical simulations. Clinical simulations can be conducted in a simulation laboratory and they can also be conducted in real-world settings. The clinical simulation approach attempts to bring the dimension of clinical context into stronger focus. This involves testing of systems with representative users doing representative tasks, in representative settings/environments. Application of methods where realistic clinical scenarios are used to drive the study of users interacting with systems under realistic conditions and settings can lead to identification of problems and issues with systems that may not be detected using traditional usability engineering methods. In conducting such studies, careful consideration is needed in creating ecologically valid test scenarios. The evidence obtained from such evaluation can be used to improve both the usability and safety of HIT. In addition, recent work has shown that clinical simulations, in particular those conducted in-situ, can lead to considerable benefits when compared to the costs of running such studies. In order to bring context of use into the testing of HIT, clinical simulation, involving observing representative users carrying out tasks in representative settings, holds considerable promise.

  4. Multi-method laboratory user evaluation of an actionable clinical performance information system: Implications for usability and patient safety.

    PubMed

    Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain

    2018-01-01

    Electronic audit and feedback (e-A&F) systems are used worldwide for care quality improvement. They measure health professionals' performance against clinical guidelines, and some systems suggest improvement actions. However, little is known about optimal interface designs for e-A&F, in particular how to present suggested actions for improvement. We developed a novel theory-informed system for primary care (the Performance Improvement plaN GeneratoR; PINGR) that covers the four principal interface components: clinical performance summaries; patient lists; detailed patient-level information; and suggested actions. As far as we are aware, this is the first report of an e-A&F system with all four interface components. (1) Use a combination of quantitative and qualitative methods to evaluate the usability of PINGR with target end-users; (2) refine existing design recommendations for e-A&F systems; (3) determine the implications of these recommendations for patient safety. We recruited seven primary care physicians to perform seven tasks with PINGR, during which we measured on-screen behaviour and eye movements. Participants subsequently completed usability questionnaires, and were interviewed in-depth. Data were integrated to: gain a more complete understanding of usability issues; enhance and explain each other's findings; and triangulate results to increase validity. Participants committed a median of 10 errors (range 8-21) when using PINGR's interface, and completed a median of five out of seven tasks (range 4-7). Errors violated six usability heuristics: clear response options; perceptual grouping and data relationships; representational formats; unambiguous description; visually distinct screens for confusable items; and workflow integration. Eye movement analysis revealed the integration of components largely supported effective user workflow, although the modular design of clinical performance summaries unnecessarily increased cognitive load. Interviews and questionnaires revealed PINGR is user-friendly, and that improved information prioritisation could further promote useful user action. Comparing our results with the wider usability literature we refine a previously published set of interface design recommendations for e-A&F. The implications for patient safety are significant regarding: user engagement; actionability; and information prioritisation. Our results also support adopting multi-method approaches in usability studies to maximise issue discovery and the credibility of findings. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Usability and Culture as Two of the Value Criteria for Evaluating the Artifact

    NASA Astrophysics Data System (ADS)

    Kurosu, Masaaki

    In this paper, the conceptual framework of the Artifact Development Analysis (ADA) and its relationship to the usability engineering are outlined. The ADA analyses the significance of all artifacts including hardware, software, humanware and system. Its viewpoint extends both in temporal and spatial dimensions. In short, it deals with the diversity of the artifact and casts the questions "why it is so" and "why it is not so". In this respect, the ADA is related to the usability engineering as one of the value attitudes. The usability engineering puts emphasis on effectiveness and efficiency. The usability is not always the value criterion of highest importance and some people sometimes put more emphasis on other criteria such as the aesthetic aspect, the cost, etc. Based on the findings of ADA, we should focus on the extent where the usability can provide the core satisfaction and we should also summarize the guideline on how the artifact should be designed.

  6. A glucose meter evaluation co-designed with both health professional and consumer input.

    PubMed

    Thompson, Harmony; Chan, Huan; Logan, Florence J; Heenan, Helen F; Taylor, Lynne; Murray, Chris; Florkowski, Christopher M; Frampton, Christopher M A; Lunt, Helen

    2013-11-22

    Health consumer's input into assessment of medical device safety is traditionally given either as part of study outcome (trial participants) or during post marketing surveillance. Direct consumer input into the methodological design of device assessment is less common. We discuss the difference in requirements for assessment of a measuring device from the consumer and clinician perspectives, using the example of hand held glucose meters. Around 80,000 New Zealanders with diabetes recently changed their glucose meter system, to enable ongoing access to PHARMAC subsidised meters and strips. Consumers were most interested in a direct comparison of their 'old' meter system (Accu-Chek Performa) with their 'new' meter system (CareSens brand, including the CareSens N POP), rather than comparisons against a laboratory standard. This direct comparison of meter/strip systems showed that the CareSens N POP meter read around 0.6 mmol/L higher than the Performa system. Whilst this difference is unlikely to result in major errors in clinical decision making such as major insulin dosing errors, this information is nevertheless of interest to consumers who switched meters so that they could maintain access to PHARMAC subsidised meters and strips. We recommend that when practical, the consumer perspective be incorporated into study design related to medical device assessment.

  7. Cognitive engineering of film library transition from film medium to digital environment in a Texas teaching hospital.

    PubMed

    Koperwhats, Martha A; Chang, Wei-Chih; Xiao, Jianguo

    2002-01-01

    Digital imaging technology promises efficient, economical, and fast service for patient care, but the challenges are great in the transition from film to a filmless (digital) environment. This change has a significant impact on the film library's personnel (film librarians) who play a leading roles in storage, classification, and retrieval of images. The objectives of this project were to study film library errors and the usability of a physical computerized system that could not be changed, while developing an intervention to reduce errors and test the usability of the intervention. Cognitive and human factors analysis were used to evaluate human-computer interaction. A workflow analysis was performed to understand the film and digital imaging processes. User and task analyses were applied to account for all behaviors involved in interaction with the system. A heuristic evaluation was used to probe the usability issues in the picture archiving and communication systems (PACS) modules. Simplified paper-based instructions were designed to familiarize the film librarians with the digital system. A usability survey evaluated the effectiveness of the instruction. The user and task analyses indicated that different users faced challenges based on their computer literacy, education, roles, and frequency of use of diagnostic imaging. The workflow analysis showed that the approaches to using the digital library differ among the various departments. The heuristic evaluation of the PACS modules showed the human-computer interface to have usability issues that prevented easy operation. Simplified instructions were designed for operation of the modules. Usability surveys conducted before and after revision of the instructions showed that performance improved. Cognitive and human factor analysis can help film librarians and other users adapt to the filmless system. Use of cognitive science tools will aid in successful transition of the film library from a film environment to a digital environment.

  8. Improving the accuracy and usability of Iowa falling weight deflectometer data.

    DOT National Transportation Integrated Search

    2013-05-01

    This study aims to improve the accuracy and usability of Iowa Falling Weight Deflectometer (FWD) data by incorporating significant : enhancements into the fully-automated software system for rapid processing of the FWD data. These enhancements includ...

  9. Experiences with establishing and implementing learning management system and computer-based test system in medical college.

    PubMed

    Park, Joo Hyun; Son, Ji Young; Kim, Sun

    2012-09-01

    The purpose of this study was to establish an e-learning system to support learning in medical education and identify solutions for improving the system. A learning management system (LMS) and computer-based test (CBT) system were established to support e-learning for medical students. A survey of 219 first- and second-grade medical students was administered. The questionnaire included 9 forced choice questions about the usability of system and 2 open-ended questions about necessary improvements to the system. The LMS consisted of a class management, class evaluation, and class attendance system. CBT consisted of a test management, item bank, and authoring tool system. The results of the survey showed a high level of satisfaction in all system usability items except for stability. Further, the advantages of the e-learning system were ensuring information accessibility, providing constant feedback, and designing an intuitive interface. Necessary improvements to the system were stability, user control, readability, and diverse device usage. Based on the findings, suggestions for developing an e-learning system to improve usability by medical students and support learning effectively are recommended.

  10. Usability and clinical efficacy of diabetes mobile applications for adults with type 2 diabetes: A systematic review.

    PubMed

    Fu, Helen; McMahon, Siobhan K; Gross, Cynthia R; Adam, Terrence J; Wyman, Jean F

    2017-09-01

    To assess the usability and clinical effectiveness of diabetes mobile applications (diabetes apps) developed for adults with type 2 diabetes. A systematic review of the usability and effectiveness of diabetes apps was conducted. Searches were performed using MEDLINE, EMBASE, COMPENDEX, and IEEE XPLORE for articles published from January 1, 2011, to January 17, 2017. Search terms included: diabetes, mobile apps, and mobile health (mHealth). The search yielded 723 abstracts of which seven usability studies and ten clinical effectiveness studies met the inclusion criteria from 20 publications. Usability, as measured by satisfaction ratings from experts and patients, ranged from 38% to 80%. Usability problem ratings ranged from moderate to catastrophic. Top usability problems are multi-steps task, limited functionality and interaction, and difficult system navigation. Clinical effectiveness, measured by reductions in HbA1c, ranged from 0.15% to 1.9%. Despite meager satisfaction ratings and major usability problems, there is some limited evidence supporting the effectiveness of diabetes apps to improve glycemic control for adults with type 2 diabetes. Findings strongly suggest that efforts to improve user satisfaction, incorporate established principles of health behavior change, and match apps to user characteristics will increase the therapeutic impact of diabetes apps. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. ODMSummary: A Tool for Automatic Structured Comparison of Multiple Medical Forms Based on Semantic Annotation with the Unified Medical Language System.

    PubMed

    Storck, Michael; Krumm, Rainer; Dugas, Martin

    2016-01-01

    Medical documentation is applied in various settings including patient care and clinical research. Since procedures of medical documentation are heterogeneous and developed further, secondary use of medical data is complicated. Development of medical forms, merging of data from different sources and meta-analyses of different data sets are currently a predominantly manual process and therefore difficult and cumbersome. Available applications to automate these processes are limited. In particular, tools to compare multiple documentation forms are missing. The objective of this work is to design, implement and evaluate the new system ODMSummary for comparison of multiple forms with a high number of semantically annotated data elements and a high level of usability. System requirements are the capability to summarize and compare a set of forms, enable to estimate the documentation effort, track changes in different versions of forms and find comparable items in different forms. Forms are provided in Operational Data Model format with semantic annotations from the Unified Medical Language System. 12 medical experts were invited to participate in a 3-phase evaluation of the tool regarding usability. ODMSummary (available at https://odmtoolbox.uni-muenster.de/summary/summary.html) provides a structured overview of multiple forms and their documentation fields. This comparison enables medical experts to assess multiple forms or whole datasets for secondary use. System usability was optimized based on expert feedback. The evaluation demonstrates that feedback from domain experts is needed to identify usability issues. In conclusion, this work shows that automatic comparison of multiple forms is feasible and the results are usable for medical experts.

  12. Comparing usability testing outcomes and functions of six electronic nursing record systems.

    PubMed

    Cho, Insook; Kim, Eunman; Choi, Woan Heui; Staggers, Nancy

    2016-04-01

    This study examined the usability of six differing electronic nursing record (ENR) systems on the efficiency, proficiency and available functions for documenting nursing care and subsequently compared the results to nurses' perceived satisfaction from a previous study. The six hospitals had different ENR systems, all with narrative nursing notes in use for more than three years. Stratified by type of nursing unit, 54 staff nurses were digitally recorded during on-site usability testing by employing validated patient care scenarios and think-aloud protocols. The time to complete specific tasks was also measured. Qualitative performance data were converted into scores on efficiency (relevancy), proficiency (accuracy), and a competency index using scoring schemes described by McGuire and Babbott. Six nurse managers and the researchers completed assessments of available ENR functions and examined computerized nursing process components including the linkages among them. For the usability test, participants' mean efficiency score was 94.2% (95% CI, 91.4-96.9%). The mean proficiency was 60.6% (95% CI, 54.3-66.8%), and the mean competency index was 59.5% (95% CI, 52.9-66.0). Efficiency scores were significantly different across ENRs as was the time to complete tasks, ranging from 226.3 to 457.2s (χ(2)=12.3, P=0.031; χ(2)=11.2, P=0.048). No significant differences were seen for proficiency scores. The coverage of the various ENRs' nursing process ranged from 67% to 100%, but only two systems had complete integration of nursing components. Two systems with high efficiency and proficiency scores had much lower usability test scores and perceived user satisfaction along with more complex navigation patterns. In terms of system usability and functions, different levels of sophistication of and interaction performance with ENR systems exist in practice. This suggests that ENRs may have variable impacts on clinical outcomes and care quality. Future studies are needed to explore ENR impact on nursing care quality, efficiency, and safety. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Advanced Metering Infrastructure based on Smart Meters

    NASA Astrophysics Data System (ADS)

    Suzuki, Hiroshi

    By specifically designating penetrations rates of advanced meters and communication technologies, devices and systems, this paper introduces that the penetration of advanced metering is important for the future development of electric power system infrastructure. It examines the state of the technology and the economical benefits of advanced metering. One result of the survey is that advanced metering currently has a penetration of about six percent of total installed electric meters in the United States. Applications to the infrastructure differ by type of organization. Being integrated with emerging communication technologies, smart meters enable several kinds of features such as, not only automatic meter reading but also distribution management control, outage management, remote switching, etc.

  14. Evaluating the usability of an interactive, bi-lingual, touchscreen-enabled breastfeeding educational programme: application of Nielson's heuristics.

    PubMed

    Joshi, Ashish; Perin, Douglas M Puricelli; Amadi, Chioma; Trout, Kate

    2015-03-05

    The study purpose was to conduct heuristic evaluation of an interactive, bilingual touchscreen-enabled breastfeeding educational programme for Hispanic women living in rural settings in Nebraska. Three raters conducted the evaluation during May 2013 using principles of Nielson's heuristics. A total of 271 screens were evaluated and included: interface (n = 5), programme sections (n = 223) and educational content (n = 43). A total of 97 heuristic violations were identified and were mostly related to interface (8 violations/5 screens) and programme components (89 violations/266 screens). The most common heuristic violations reported were recognition rather than recall (62%, n = 60), consistency and standards (14%, n = 14) and match between the system and real world (9%, n = 9). Majority of the heuristic violations had minor usability issues (73%, n = 71). The only grade 4 heuristic violation reported was due to the visibility of system status in the assessment modules. The results demonstrated that the system was more consistent with Nielsen's usability heuristics. With Nielsen's usability heuristics, it is possible to identify problems in a timely manner, and help facilitate the identification and prioritisation of problems needing urgent attention at an earlier stage before the final deployment of the system.

  15. Cost Effective Development of Usable Systems: Gaps between HCI and Software Architecture Design

    NASA Astrophysics Data System (ADS)

    Folmer, Eelke; Bosch, Jan

    A software product with poor usability is likely to fail in a highly competitive market; therefore software developing organizations are paying more and more attention to ensuring the usability of their software. Practice, however, shows that product quality (which includes usability among others) is not that high as it could be. Studies of software projects (Pressman, 2001) reveal that organizations spend a relative large amount of money and effort on fixing usability problems during late stage development. Some of these problems could have been detected and fixed much earlier. This avoidable rework leads to high costs and because during development different tradeoffs have to be made, for example between cost and quality leads to systems with less than optimal usability. This problem has been around for a couple of decades especially after software engineering (SE) and human computer interaction (HCI) became disciplines on their own. While both disciplines developed themselves, several gaps appeared which are now receiving increased attention in research literature. Major gaps of understanding, both between suggested practice and how software is actually developed in industry, but also between the best practices of each of the fields have been identified (Carrol et al, 1994, Bass et al, 2001, Folmer and Bosch, 2002). In addition, there are gaps in the fields of differing terminology, concepts, education, and methods.

  16. Usability analysis of industrial cooking equipment.

    PubMed

    Calado, Alexana Vilar Soares; Soares, Marcelo Márcio

    2012-01-01

    This paper refers to the comparative study of the equipment used for cooking in commercial of kitchens restaurants that use the system of traditional cooking and those ones which use the system called smart cooking (combination oven). The study investigates the usability issues concerning to the two systems, analyzing comparatively the aspects related to anthropometry, dimensional variables, the use of the product and also the product safety, as well as issues of information related to operation of the new concepts of cooking in intelligent systems.

  17. User Guide: How to Use and Operate Virtual Reality Equipment in the Systems Assessment and Usability Laboratory (SAUL) for Conducting Demonstrations

    DTIC Science & Technology

    2017-08-01

    ARL-TN-0839 ● AUG 2017 US Army Research Laboratory User Guide: How to Use and Operate Virtual Reality Equipment in the Systems...ARL-TN-0839 ● AUG 2017 US Army Research Laboratory User Guide: How to Use and Operate Virtual Reality Equipment in the Systems...September 2017 4. TITLE AND SUBTITLE User Guide: How to Use and Operate Virtual Reality Equipment in the Systems Assessment and Usability Laboratory

  18. Effectiveness and usability of Scanning Wizard software: a tool for enhancing switch scanning.

    PubMed

    Koester, Heidi Horstmann; Simpson, Richard C

    2017-11-24

    Scanning Wizard software helps scanning users improve the setup of their switch and scanning system. This study evaluated Scanning Wizard's effectiveness and usability. Ten people who use switch scanning and ten practitioners used Scanning Wizard in the initial session. Usability was high, based on survey responses averaging over 4.5 out of 5, and qualitative feedback was very positive. Five switch users were able to complete the multi-week protocol, using settings on their own scanning system that were recommended from the Scanning Wizard session. Using these revised settings, text entry rates improved by an average of 71%, ranging from 29% to 172% improvement. Results suggest that Scanning Wizard is a useful tool for improving the configuration of scanning systems for people who use switch scanning to communicate. Implications for Rehabilitation Some individuals with severe physical impairments use switch scanning for spoken and written communication. Scanning Wizard software helps scanning users improve the setup of their switch and scanning system. This study demonstrated high usability of Scanning Wizard (with 10 switch userpractitioner teams) and increased text entry rate by an average of 71% (for five switch users). Results suggest that Scanning Wizard is a useful tool for improving the configuration of scanning systems for people who use switch scanning to communicate.

  19. Qualitative and quantitative evaluation of EHR-integrated mobile patient questionnaires regarding usability and cost-efficiency.

    PubMed

    Fritz, Fleur; Balhorn, Sebastian; Riek, Markus; Breil, Bernhard; Dugas, Martin

    2012-05-01

    The objective of this evaluation study is to assess a web-based application, currently available on iPad, to document questionnaires regarding patient reported outcomes such as quality of life. Based on the single source approach, the results of these questionnaires are available in the electronic health record to be used for treatment and research purposes. The assessment focuses on the usability and efficiency of the system. The system usability scale questionnaire with seven additional items was used to rate the usability by the patients. It was formally validated by a Cronbach Alpha test. In addition, semi-structured interviews were conducted with patients and medical staff. Time and cost measures, based on official tables of costs, were taken through workflow observations. This study was conducted in the department of dermatology at the University Hospital of Münster, Germany from April to June 2011. Using the web-based application questionnaire, results about patient reported outcomes like quality of life are immediately available in the electronic health record and can be used for treatment or research purposes. 118 patients and four staff members participated in the study. The usability score reached 80 from 100 points and patients as well as medical staff stated in the interviews that the usability of the web-based system was high, and they preferred it to the previously used paper-based questionnaires. In the setting of our pilot department the mobile devices amortized their costs after 6.7 months. In general, depending on the professional group who are going to post process the paper-based forms, the earliest break-even point to use mobile questionnaires is at 1737 paper sheets per year. The mobile patient questionnaires, integrated into the electronic health record, were well accepted in our pilot setting with high usability scores from patients and medical staff alike. The system has also proved to be cost-efficient compared to the paper-based workflow, given that a certain number of questionnaires is used per year. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  20. Using archived ITS data to measure the operational benefits of a system-wide adaptive ramp metering system.

    DOT National Transportation Integrated Search

    2008-12-01

    A System-Wide Adaptive Ramp Metering (SWARM) system has been implemented in the Portland, Oregon metropolitan area, replacing the previous pre-timed ramp-metering system that had been in operation since 1981. SWARM has been deployed on six major corr...

  1. Engineering the electronic health record for safety: a multi-level video-based approach to diagnosing and preventing technology-induced error arising from usability problems.

    PubMed

    Borycki, Elizabeth M; Kushniruk, Andre W; Kuwata, Shigeki; Kannry, Joseph

    2011-01-01

    Electronic health records (EHRs) promise to improve and streamline healthcare through electronic entry and retrieval of patient data. Furthermore, based on a number of studies showing their positive benefits, they promise to reduce medical error and make healthcare safer. However, a growing body of literature has clearly documented that if EHRS are not designed properly and with usability as an important goal in their design, rather than reducing error, EHR deployment has the potential to actually increase medical error. In this paper we describe our approach to engineering (and reengineering) EHRs in order to increase their beneficial potential while at the same time improving their safety. The approach described in this paper involves an integration of the methods of usability analysis with video analysis of end users interacting with EHR systems and extends the evaluation of the usability of EHRs to include the assessment of the impact of these systems on work practices. Using clinical simulations, we analyze human-computer interaction in real healthcare settings (in a portable, low-cost and high fidelity manner) and include both artificial and naturalistic data collection to identify potential usability problems and sources of technology-induced error prior to widespread system release. Two case studies where the methods we have developed and refined have been applied at different levels of user-computer interaction are described.

  2. Usability Assessment of the Missouri Cancer Registry's Published Interactive Mapping Reports: Round One.

    PubMed

    Ben Ramadan, Awatef Ahmed; Jackson-Thompson, Jeannette; Schmaltz, Chester Lee

    2017-08-04

     Many users of spatial data have difficulty interpreting information in health-related spatial reports. The Missouri Cancer Registry and Research Center (MCR-ARC) has produced interactive reports for several years. These reports have never been tested for usability.  The aims of this study were to: (1) conduct a multi-approach usability testing study to understand ease of use (user friendliness) and user satisfaction; and (2) evaluate the usability of MCR-ARC's published InstantAtlas reports.   An institutional review board (IRB) approved mixed methodology usability testing study using a convenience sample of health professionals. A recruiting email was sent to faculty in the Master of Public Health program and to faculty and staff in the Department of Health Management and Informatics at the University of Missouri-Columbia. The study included 7 participants. The test included a pretest questionnaire, a multi-task usability test, and the System Usability Scale (SUS). Also, the researchers collected participants' comments about the tested maps immediately after every trial. Software was used to record the computer screen during the trial and the participants' spoken comments. Several performance and usability metrics were measured to evaluate the usability of MCR-ARC's published mapping reports. Of the 10 assigned tasks, 6 reached a 100% completion success rate, and this outcome was relative to the complexity of the tasks. The simple tasks were handled more efficiently than the complicated tasks. The SUS score ranged between 20-100 points, with an average of 62.7 points and a median of 50.5 points. The tested maps' effectiveness outcomes were better than the efficiency and satisfaction outcomes. There was a statistically significant relationship between the subjects' performance on the study test and the users' previous experience with geographic information system (GIS) tools (P=.03). There were no statistically significant relationships between users' performance and satisfaction and their education level, work type, or previous experience in health care (P>.05). There were strong positive correlations between the three measured usability elements. The tested maps should undergo an extensive refining and updating to overcome all the discovered usability issues and meet the perspectives and needs of the tested maps' potential users. The study results might convey the perspectives of academic health professionals toward GIS health data. We need to conduct a second-round usability study with public health practitioners and cancer professionals who use GIS tools on a routine basis. Usability testing should be conducted before and after releasing MCR-ARC's maps in the future. ©Awatef Ahmed Ben Ramadan, Jeannette Jackson-Thompson, Chester Lee Schmaltz. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 04.08.2017.

  3. Usability Assessment of the Missouri Cancer Registry’s Published Interactive Mapping Reports: Round One

    PubMed Central

    Jackson-Thompson, Jeannette; Schmaltz, Chester Lee

    2017-01-01

    Background  Many users of spatial data have difficulty interpreting information in health-related spatial reports. The Missouri Cancer Registry and Research Center (MCR-ARC) has produced interactive reports for several years. These reports have never been tested for usability. Objective  The aims of this study were to: (1) conduct a multi-approach usability testing study to understand ease of use (user friendliness) and user satisfaction; and (2) evaluate the usability of MCR-ARC’s published InstantAtlas reports. Methods   An institutional review board (IRB) approved mixed methodology usability testing study using a convenience sample of health professionals. A recruiting email was sent to faculty in the Master of Public Health program and to faculty and staff in the Department of Health Management and Informatics at the University of Missouri-Columbia. The study included 7 participants. The test included a pretest questionnaire, a multi-task usability test, and the System Usability Scale (SUS). Also, the researchers collected participants’ comments about the tested maps immediately after every trial. Software was used to record the computer screen during the trial and the participants’ spoken comments. Several performance and usability metrics were measured to evaluate the usability of MCR-ARC’s published mapping reports. Results Of the 10 assigned tasks, 6 reached a 100% completion success rate, and this outcome was relative to the complexity of the tasks. The simple tasks were handled more efficiently than the complicated tasks. The SUS score ranged between 20-100 points, with an average of 62.7 points and a median of 50.5 points. The tested maps’ effectiveness outcomes were better than the efficiency and satisfaction outcomes. There was a statistically significant relationship between the subjects’ performance on the study test and the users’ previous experience with geographic information system (GIS) tools (P=.03). There were no statistically significant relationships between users’ performance and satisfaction and their education level, work type, or previous experience in health care (P>.05). There were strong positive correlations between the three measured usability elements. Conclusions The tested maps should undergo an extensive refining and updating to overcome all the discovered usability issues and meet the perspectives and needs of the tested maps’ potential users. The study results might convey the perspectives of academic health professionals toward GIS health data. We need to conduct a second-round usability study with public health practitioners and cancer professionals who use GIS tools on a routine basis. Usability testing should be conducted before and after releasing MCR-ARC’s maps in the future. PMID:28778842

  4. Ambient Assisted Living spaces validation by services and devices simulation.

    PubMed

    Fernández-Llatas, Carlos; Mocholí, Juan Bautista; Sala, Pilar; Naranjo, Juan Carlos; Pileggi, Salvatore F; Guillén, Sergio; Traver, Vicente

    2011-01-01

    The design of Ambient Assisted Living (AAL) products is a very demanding challenge. AAL products creation is a complex iterative process which must accomplish exhaustive prerequisites about accessibility and usability. In this process the early detection of errors is crucial to create cost-effective systems. Computer-assisted tools can suppose a vital help to usability designers in order to avoid design errors. Specifically computer simulation of products in AAL environments can be used in all the design phases to support the validation. In this paper, a computer simulation tool for supporting usability designers in the creation of innovative AAL products is presented. This application will benefit their work saving time and improving the final system functionality.

  5. Usability of a barcode scanning system as a means of data entry on a PDA for self-report health outcome questionnaires: a pilot study in individuals over 60 years of age

    PubMed Central

    Boissy, Patrick; Jacobs, Karen; Roy, Serge H

    2006-01-01

    Background Throughout the medical and paramedical professions, self-report health status questionnaires are used to gather patient-reported outcome measures. The objective of this pilot study was to evaluate in individuals over 60 years of age the usability of a PDA-based barcode scanning system with a text-to-speech synthesizer to collect data electronically from self-report health outcome questionnaires. Methods Usability of the system was tested on a sample of 24 community-living older adults (7 men, 17 women) ranging in age from 63 to 93 years. After receiving a brief demonstration on the use of the barcode scanner, participants were randomly assigned to complete two sets of 16 questions using the bar code wand scanner for one set and a pen for the other. Usability was assessed using directed interviews with a usability questionnaire and performance-based metrics (task times, errors, sources of errors). Results Overall, participants found barcode scanning easy to learn, easy to use, and pleasant. Participants were marginally faster in completing the 16 survey questions when using pen entry (20/24 participants). The mean response time with the barcode scanner was 31 seconds longer than traditional pen entry for a subset of 16 questions (p = 0.001). The responsiveness of the scanning system, expressed as first scan success rate, was less than perfect, with approximately one-third of first scans requiring a rescan to successfully capture the data entry. The responsiveness of the system can be explained by a combination of factors such as the location of the scanning errors, the type of barcode used as an answer field in the paper version, and the optical characteristics of the barcode scanner. Conclusion The results presented in this study offer insights regarding the feasibility, usability and effectiveness of using a barcode scanner with older adults as an electronic data entry method on a PDA. While participants in this study found their experience with the barcode scanning system enjoyable and learned to become proficient in its use, the responsiveness of the system constitutes a barrier to wide-scale use of such a system. Optimizing the graphical presentation of the information on paper should significantly increase the system's responsiveness. PMID:17184533

  6. Design and Usability Evaluation of Social Mobile Diabetes Management System in the Gulf Region.

    PubMed

    Alanzi, Turki; Istepanian, Robert; Philip, Nada

    2016-09-26

    The prevalence of diabetes in the Gulf States is one of the highest globally. It is estimated that 20% of the population in the region has been diagnosed with diabetes and according to the International Diabetes Federation (IDF), five of the IDF's "top 10" countries for diabetes prevalence in 2011 and projected for 2030 are in this region. In recent years, there have been an increasing number of clinical studies advocating the use of mobile phone technology for diabetes self-management with improved clinical outcomes. However, there are few studies to date addressing the application of mobile diabetes management in the Gulf region, particularly in the Kingdom of Saudi Arabia (KSA), where there is exponential increase in mobile phone usage and access to social networking. The objective of this paper is to present the design and development of a new mobile health system for social behavioral change and management tailored for Saudi patients with diabetes called Saudi Arabia Networking for Aiding Diabetes (SANAD). A usability study for the SANAD system is presented to validate the acceptability of using mobile technologies among patients with diabetes in the KSA and the Gulf region. The SANAD system was developed using mobile phone technology with diabetes management and social networking modules. For the usability study the Questionnaire for User Interaction Satisfaction was used to evaluate the usability aspect of the SANAD system. A total of 33 users with type 2 diabetes participated in the study. The key modules of the SANAD system consist of (1) a mobile diabetes management module; (2) a social networking module; and (3) a cognitive behavioral therapy module for behavioral change issues. The preliminary results of the usability study indicated general acceptance of the patients in using the system with higher usability rating in patients with type 2 diabetes. We found that the acceptability of the system was high among Saudi patients with diabetes, and ongoing work in this research area is underway to conduct a clinical pilot study in the KSA for patients with type 2 diabetes. The wide deployment of such a system is timely and required in the Gulf region due to the wide use of mobile phones and social networking mediums.

  7. Design and Usability Evaluation of Social Mobile Diabetes Management System in the Gulf Region

    PubMed Central

    2016-01-01

    Background The prevalence of diabetes in the Gulf States is one of the highest globally. It is estimated that 20% of the population in the region has been diagnosed with diabetes and according to the International Diabetes Federation (IDF), five of the IDF’s “top 10” countries for diabetes prevalence in 2011 and projected for 2030 are in this region. In recent years, there have been an increasing number of clinical studies advocating the use of mobile phone technology for diabetes self-management with improved clinical outcomes. However, there are few studies to date addressing the application of mobile diabetes management in the Gulf region, particularly in the Kingdom of Saudi Arabia (KSA), where there is exponential increase in mobile phone usage and access to social networking. Objective The objective of this paper is to present the design and development of a new mobile health system for social behavioral change and management tailored for Saudi patients with diabetes called Saudi Arabia Networking for Aiding Diabetes (SANAD). A usability study for the SANAD system is presented to validate the acceptability of using mobile technologies among patients with diabetes in the KSA and the Gulf region. Methods The SANAD system was developed using mobile phone technology with diabetes management and social networking modules. For the usability study the Questionnaire for User Interaction Satisfaction was used to evaluate the usability aspect of the SANAD system. A total of 33 users with type 2 diabetes participated in the study. Results The key modules of the SANAD system consist of (1) a mobile diabetes management module; (2) a social networking module; and (3) a cognitive behavioral therapy module for behavioral change issues. The preliminary results of the usability study indicated general acceptance of the patients in using the system with higher usability rating in patients with type 2 diabetes. Conclusions We found that the acceptability of the system was high among Saudi patients with diabetes, and ongoing work in this research area is underway to conduct a clinical pilot study in the KSA for patients with type 2 diabetes. The wide deployment of such a system is timely and required in the Gulf region due to the wide use of mobile phones and social networking mediums. PMID:27670696

  8. Promoting Higher Order Thinking Skills via IPTEACES e-Learning Framework in the Learning of Information Systems Units

    ERIC Educational Resources Information Center

    Isaias, Pedro; Issa, Tomayess; Pena, Nuno

    2014-01-01

    When developing and working with various types of devices from a supercomputer to an iPod Mini, it is essential to consider the issues of Human Computer Interaction (HCI) and Usability. Developers and designers must incorporate HCI, Usability and user satisfaction in their design plans to ensure that systems are easy to learn, effective,…

  9. Integrating an embedded system in a microwave moisture meter

    USDA-ARS?s Scientific Manuscript database

    The conversion of a PC- or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter measures the attenuation and phase shift of low power microwaves traversing the sample, from which the dielectric properties are calculated. T...

  10. Integrating an Embedded System within a Microwave Moisture Meter

    USDA-ARS?s Scientific Manuscript database

    In this paper, the conversion of a PC or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter uses low-power microwaves to measure the attenuation and phase shift of the sample, from which the dielectric properties are cal...

  11. Using a medical simulation center as an electronic health record usability laboratory

    PubMed Central

    Landman, Adam B; Redden, Lisa; Neri, Pamela; Poole, Stephen; Horsky, Jan; Raja, Ali S; Pozner, Charles N; Schiff, Gordon; Poon, Eric G

    2014-01-01

    Usability testing is increasingly being recognized as a way to increase the usability and safety of health information technology (HIT). Medical simulation centers can serve as testing environments for HIT usability studies. We integrated the quality assurance version of our emergency department (ED) electronic health record (EHR) into our medical simulation center and piloted a clinical care scenario in which emergency medicine resident physicians evaluated a simulated ED patient and documented electronically using the ED EHR. Meticulous planning and close collaboration with expert simulation staff was important for designing test scenarios, pilot testing, and running the sessions. Similarly, working with information systems teams was important for integration of the EHR. Electronic tools are needed to facilitate entry of fictitious clinical results while the simulation scenario is unfolding. EHRs can be successfully integrated into existing simulation centers, which may provide realistic environments for usability testing, training, and evaluation of human–computer interactions. PMID:24249778

  12. Addressing critical issues in the development of an Oncology Information System.

    PubMed

    Urda, D; Ribelles, N; Subirats, J L; Franco, L; Alba, E; Jerez, J M

    2013-05-01

    This paper presents the experience on the design and implementation of a user-centered Oncology Information System developed for the Medical Oncology Department at the "Hospital Universitario Virgen de la Victoria", in Málaga, Spain. The project focused on the aspects considered in the literature as critical factors for a successful deployment and usage of a health information system. System usability, adequate technology, integration of clinical routines, real-time statistical analysis of data, information confidentiality and standard protocol-based external interconnection were the key aspects considered. The developed system is based on a web application with a modular and layered architecture accounting for usability, ease of maintenance and further system development. Evaluation of system usability was carried at three and fifteen months after system deployment to analyze the advantages/disadvantages experienced by the end-users. A thorough prior analysis of clinical activities and workflows, the use of the adequate technology, and the availability of data analysis tools will almost guarantee success in the deployment of an Oncology Information System. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. A Usability Study of Users’ Perceptions Toward a Multimedia Computer-Assisted Learning Tool for Neuroanatomy

    PubMed Central

    Gould, Douglas J.; Terrell, Mark A.; Fleming, Jo

    2015-01-01

    This usability study evaluated users’ perceptions of a multimedia prototype for a new e-learning tool: Anatomy of the Central Nervous System: A Multimedia Course. Usability testing is a collection of formative evaluation methods that inform the developmental design of e-learning tools to maximize user acceptance, satisfaction, and adoption. Sixty-two study participants piloted the prototype and completed a usability questionnaire designed to measure two usability properties: program need and program applicability. Statistical analyses were used to test the hypothesis that the multimedia prototype was well designed and highly usable, it was perceived as: 1) highly needed across a spectrum of educational contexts, 2) highly applicable in supporting the pedagogical processes of teaching and learning neuroanatomy, and 3) was highly usable by all types of users. Three independent variables represented user differences: level of expertise (faculty vs. student), age, and gender. Analysis of the results supports the research hypotheses that the prototype was designed well for different types of users in various educational contexts and for supporting the pedagogy of neuroanatomy. In addition, the results suggest that the multimedia program will be most useful as a neuroanatomy review tool for health-professions students preparing for licensing or board exams. This study demonstrates the importance of integrating quality properties of usability with principles of human learning during the instructional design process for multimedia products. PMID:19177405

  14. Retrograde contamination and practical handling of urine-meters: a comparison of three systems for the measurement of hourly diuresis in an experimental bladder-drainage model and in clinical use.

    PubMed

    Rasmussen, A; Frimodt-Møller, N; Espersen, F; Roed, M; Frimodt-Møller, C

    1996-08-01

    To compare three different urine metering systems for their ability to prevent retrograde contamination in an in vitro model of a closed urinary drainage system and for qualities important to their practical handling in a clinical setting. Using three urine-meters (the Braun Ureofix 511, the Kendall Curity 4000 and the Unoplast Unometer 500) the in vitro model was constantly flushed with a solution of Mueller-Hinton broth diluted with saline. On the first day, the urine collecting bag was inoculated with 10(8) cells of Pseudomonas aeruginosa. The system was operated for 12 days with daily sampling of the model bladder to detect any contamination. After 12 days the experiment was stopped and sampling performed at various locations, including the urine-meter and the tubing. Nine of each type of urine-meter were tested, i.e. three in three different experiments. In the clinical study, 45 patients were randomized to each of the three urine-meters and the nurses attending them were asked to complete a questionnaire on the practical handling of the urine-meters. When the urine-meters was omitted from the model system, the 'bladder' became contaminated with the test bacteria within 3 days. None of the nine Unometer 500 systems became contaminated, compared with four of each of the other two systems (P < 0.05). In clinical use, the Unometer 500 and Ureofix 511 were easier to suspend and empty than was the Curity 4000. The Unometer 500 was significantly easier to handle when the collecting bag was emptied. Urine-meters can prevent retrograde contamination in a closed bladder-drainage model, but the degree of prevention depends upon the type of urine-meter. In daily practice, there were differences in the ease of suspension of the systems and in the emptying of the urine-meter and collecting bag.

  15. Hybrid P300-based brain-computer interface to improve usability for people with severe motor disability: electromyographic signals for error correction during a spelling task.

    PubMed

    Riccio, Angela; Holz, Elisa Mira; Aricò, Pietro; Leotta, Francesco; Aloise, Fabio; Desideri, Lorenzo; Rimondini, Matteo; Kübler, Andrea; Mattia, Donatella; Cincotti, Febo

    2015-03-01

    To evaluate the impact of a hybrid control on usability of a P300-based brain-computer interface (BCI) system that was designed to control an assistive technology software and was integrated with an electromyographic channel for error correction. Proof-of-principle study with a convenience sample. Neurologic rehabilitation hospital. Participants (N=11) in this pilot study included healthy (n=8) and severely motor impaired (n=3) persons. The 3 people with severe motor disability were identified as potential candidates to benefit from the proposed hybrid BCI system for communication and environmental interaction. To eventually investigate the improvement in usability, we compared 2 modalities of BCI system control: a P300-based and a hybrid P300 electromyographic-based mode of control. System usability was evaluated according to the following outcome measures within 3 domains: (1) effectiveness (overall system accuracy and P300-based BCI accuracy); (2) efficiency (throughput time and users' workload); and (3) satisfaction (users' satisfaction). We also considered the information transfer rate and time for selection. Findings obtained in healthy participants were in favor of a higher usability of the hybrid control as compared with the nonhybrid. A similar trend was indicated by the observational results gathered from each of the 3 potential end-users. The proposed hybrid BCI control modality could provide end-users with severe motor disability with an option to exploit some residual muscular activity, which could not be fully reliable for properly controlling an assistive technology device. The findings reported in this pilot study encourage the implementation of a clinical trial involving a large cohort of end-users. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. ODMSummary: A Tool for Automatic Structured Comparison of Multiple Medical Forms Based on Semantic Annotation with the Unified Medical Language System

    PubMed Central

    Krumm, Rainer; Dugas, Martin

    2016-01-01

    Introduction Medical documentation is applied in various settings including patient care and clinical research. Since procedures of medical documentation are heterogeneous and developed further, secondary use of medical data is complicated. Development of medical forms, merging of data from different sources and meta-analyses of different data sets are currently a predominantly manual process and therefore difficult and cumbersome. Available applications to automate these processes are limited. In particular, tools to compare multiple documentation forms are missing. The objective of this work is to design, implement and evaluate the new system ODMSummary for comparison of multiple forms with a high number of semantically annotated data elements and a high level of usability. Methods System requirements are the capability to summarize and compare a set of forms, enable to estimate the documentation effort, track changes in different versions of forms and find comparable items in different forms. Forms are provided in Operational Data Model format with semantic annotations from the Unified Medical Language System. 12 medical experts were invited to participate in a 3-phase evaluation of the tool regarding usability. Results ODMSummary (available at https://odmtoolbox.uni-muenster.de/summary/summary.html) provides a structured overview of multiple forms and their documentation fields. This comparison enables medical experts to assess multiple forms or whole datasets for secondary use. System usability was optimized based on expert feedback. Discussion The evaluation demonstrates that feedback from domain experts is needed to identify usability issues. In conclusion, this work shows that automatic comparison of multiple forms is feasible and the results are usable for medical experts. PMID:27736972

  17. Methods of measuring pumpage through closed-conduit irrigation systems

    USGS Publications Warehouse

    Kjelstrom, L.C.

    1991-01-01

    Methods of measuring volumes of water withdrawn from the Snake River and its tributaries and pumped through closed-conduit irrigation systems were needed for equitable management of and resolution of conflicts over water use. On the basis of evaluations and field tests by researchers from the University of Idaho, Water Resources Research Institute, Moscow, Idaho, an impeller meter was selected to monitor pumpage through closed-conduit systems. In 1988, impeller meters were installed at 20 pumping stations along the Snake River between the Upper Salmon Falls and C.J. Strike Dams. Impeller-derived pumpage data were adjusted if they differed substantially from ultrasonic flow-meter- or current-meter-derived values. Comparisons of pumpage data obtained by ultrasonic flow-meter and current-meter measurements indicated that the ultrasonic flow meter was a reliable means to check operation of impeller meters. The equipment generally performed satisfactorily, and reliable pumpage data could be obtained using impeller meters in closed-conduit irrigation systems. Many pumping stations that divert water from the Snake River for irrigation remain unmeasured; however, regression analyses indicate that total pumpage can be reasonably estimated on the basis of electrical power consumption data, an approximation of total head at a pumping station, and a derived coefficient.

  18. Health Information Technology Usability Evaluation Scale (Health-ITUES) for Usability Assessment of Mobile Health Technology: Validation Study.

    PubMed

    Schnall, Rebecca; Cho, Hwayoung; Liu, Jianfang

    2018-01-05

    Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. ©Rebecca Schnall, Hwayoung Cho, Jianfang Liu. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 05.01.2018.

  19. Health Information Technology Usability Evaluation Scale (Health-ITUES) for Usability Assessment of Mobile Health Technology: Validation Study

    PubMed Central

    Cho, Hwayoung; Liu, Jianfang

    2018-01-01

    Background Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. Objective The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. Methods A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. Results The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. Conclusions The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. PMID:29305343

  20. An evaluation method of computer usability based on human-to-computer information transmission model.

    PubMed

    Ogawa, K

    1992-01-01

    This paper proposes a new evaluation and prediction method for computer usability. This method is based on our two previously proposed information transmission measures created from a human-to-computer information transmission model. The model has three information transmission levels: the device, software, and task content levels. Two measures, called the device independent information measure (DI) and the computer independent information measure (CI), defined on the software and task content levels respectively, are given as the amount of information transmitted. Two information transmission rates are defined as DI/T and CI/T, where T is the task completion time: the device independent information transmission rate (RDI), and the computer independent information transmission rate (RCI). The method utilizes the RDI and RCI rates to evaluate relatively the usability of software and device operations on different computer systems. Experiments using three different systems, in this case a graphical information input task, confirm that the method offers an efficient way of determining computer usability.

  1. Semantic Indexing of Medical Learning Objects: Medical Students' Usage of a Semantic Network

    PubMed Central

    Gießler, Paul; Ohnesorge-Radtke, Ursula; Spreckelsen, Cord

    2015-01-01

    Background The Semantically Annotated Media (SAM) project aims to provide a flexible platform for searching, browsing, and indexing medical learning objects (MLOs) based on a semantic network derived from established classification systems. Primarily, SAM supports the Aachen emedia skills lab, but SAM is ready for indexing distributed content and the Simple Knowledge Organizing System standard provides a means for easily upgrading or even exchanging SAM’s semantic network. There is a lack of research addressing the usability of MLO indexes or search portals like SAM and the user behavior with such platforms. Objective The purpose of this study was to assess the usability of SAM by investigating characteristic user behavior of medical students accessing MLOs via SAM. Methods In this study, we chose a mixed-methods approach. Lean usability testing was combined with usability inspection by having the participants complete four typical usage scenarios before filling out a questionnaire. The questionnaire was based on the IsoMetrics usability inventory. Direct user interaction with SAM (mouse clicks and pages accessed) was logged. Results The study analyzed the typical usage patterns and habits of students using a semantic network for accessing MLOs. Four scenarios capturing characteristics of typical tasks to be solved by using SAM yielded high ratings of usability items and showed good results concerning the consistency of indexing by different users. Long-tail phenomena emerge as they are typical for a collaborative Web 2.0 platform. Suitable but nonetheless rarely used keywords were assigned to MLOs by some users. Conclusions It is possible to develop a Web-based tool with high usability and acceptance for indexing and retrieval of MLOs. SAM can be applied to indexing multicentered repositories of MLOs collaboratively. PMID:27731860

  2. Semantic Indexing of Medical Learning Objects: Medical Students' Usage of a Semantic Network.

    PubMed

    Tix, Nadine; Gießler, Paul; Ohnesorge-Radtke, Ursula; Spreckelsen, Cord

    2015-11-11

    The Semantically Annotated Media (SAM) project aims to provide a flexible platform for searching, browsing, and indexing medical learning objects (MLOs) based on a semantic network derived from established classification systems. Primarily, SAM supports the Aachen emedia skills lab, but SAM is ready for indexing distributed content and the Simple Knowledge Organizing System standard provides a means for easily upgrading or even exchanging SAM's semantic network. There is a lack of research addressing the usability of MLO indexes or search portals like SAM and the user behavior with such platforms. The purpose of this study was to assess the usability of SAM by investigating characteristic user behavior of medical students accessing MLOs via SAM. In this study, we chose a mixed-methods approach. Lean usability testing was combined with usability inspection by having the participants complete four typical usage scenarios before filling out a questionnaire. The questionnaire was based on the IsoMetrics usability inventory. Direct user interaction with SAM (mouse clicks and pages accessed) was logged. The study analyzed the typical usage patterns and habits of students using a semantic network for accessing MLOs. Four scenarios capturing characteristics of typical tasks to be solved by using SAM yielded high ratings of usability items and showed good results concerning the consistency of indexing by different users. Long-tail phenomena emerge as they are typical for a collaborative Web 2.0 platform. Suitable but nonetheless rarely used keywords were assigned to MLOs by some users. It is possible to develop a Web-based tool with high usability and acceptance for indexing and retrieval of MLOs. SAM can be applied to indexing multicentered repositories of MLOs collaboratively.

  3. A usability study of a mobile health application for rural Ghanaian midwives.

    PubMed

    Vélez, Olivia; Okyere, Portia Boakye; Kanter, Andrew S; Bakken, Suzanne

    2014-01-01

    Midwives in rural Ghana work at the frontline of the health care system, where they have access to essential data about the patient population. However, current methods of data capture, primarily pen and paper, make the data neither accessible nor usable for monitoring patient care or program evaluation. Electronic health (eHealth) systems present a potential mechanism for enhancing the roles of midwives by providing tools for collecting, exchanging, and viewing patient data as well as offering midwives the possibility for receiving information and decision support. Introducing such technology in low-resource settings has been challenging because of low levels of user acceptance, software design that does not match the end-user environment, and/or unforeseen challenges such as irregular power availability. These challenges are often attributable to a lack of understanding by the software developers of the end users' needs and work environment. A mobile health (mHealth) application known as mClinic was designed to support midwife access to the Millennium Village-Global Network, an eHealth delivery platform that captures data for managing patient care as well as program evaluation and monitoring, decision making, and management. We conducted a descriptive usability study composed of 3 phases to evaluate an mClinic prototype: 1) hybrid lab-live software evaluation of mClinic to identify usability issues; 2) completion of a usability questionnaire; and 3) interviews that included low-fidelity prototyping of new functionality proposed by midwives. The heuristic evaluation identified usability problems related to 4 of 8 usability categories. Analysis of usability questionnaire data indicated that the midwives perceived mClinic as useful but were more neutral about the ease of use. Analysis of midwives' reactions to low-fidelity prototypes during the interview process supported the applicability of mClinic to midwives' work and identified the need for additional functionality. User acceptance is essential for the success of any mHealth implementation. Usability testing identified mClinic development flaws and needed software enhancements. © 2014 by the American College of Nurse-Midwives.

  4. The value of Retrospective and Concurrent Think Aloud in formative usability testing of a physician data query tool.

    PubMed

    Peute, Linda W P; de Keizer, Nicolette F; Jaspers, Monique W M

    2015-06-01

    To compare the performance of the Concurrent (CTA) and Retrospective (RTA) Think Aloud method and to assess their value in a formative usability evaluation of an Intensive Care Registry-physician data query tool designed to support ICU quality improvement processes. Sixteen representative intensive care physicians participated in the usability evaluation study. Subjects were allocated to either the CTA or RTA method by a matched randomized design. Each subject performed six usability-testing tasks of varying complexity in the query tool in a real-working context. Methods were compared with regard to number and type of problems detected. Verbal protocols of CTA and RTA were analyzed in depth to assess differences in verbal output. Standardized measures were applied to assess thoroughness in usability problem detection weighted per problem severity level and method overall effectiveness in detecting usability problems with regard to the time subjects spent per method. The usability evaluation of the data query tool revealed a total of 43 unique usability problems that the intensive care physicians encountered. CTA detected unique usability problems with regard to graphics/symbols, navigation issues, error messages, and the organization of information on the query tool's screens. RTA detected unique issues concerning system match with subjects' language and applied terminology. The in-depth verbal protocol analysis of CTA provided information on intensive care physicians' query design strategies. Overall, CTA performed significantly better than RTA in detecting usability problems. CTA usability problem detection effectiveness was 0.80 vs. 0.62 (p<0.05) respectively, with an average difference of 42% less time spent per subject compared to RTA. In addition, CTA was more thorough in detecting usability problems of a moderate (0.85 vs. 0.7) and severe nature (0.71 vs. 0.57). In this study, the CTA is more effective in usability-problem detection and provided clarification of intensive care physician query design strategies to inform redesign of the query tool. However, CTA does not outperform RTA. The RTA additionally elucidated unique usability problems and new user requirements. Based on the results of this study, we recommend the use of CTA in formative usability evaluation studies of health information technology. However, we recommend further research on the application of RTA in usability studies with regard to user expertise and experience when focusing on user profile customized (re)design. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Analysing Smart Metering Systems from a Consumer Perspective

    NASA Astrophysics Data System (ADS)

    Yesudas, Rani

    Many countries are deploying smart meters and Advanced Metering Infrastructure systems as part of demand management and grid modernisation efforts. Several of these projects are facing consumer resistance. The advertised benefits to the consumer appear mainly monetary but detailed analysis shows that financial benefits are hard to realise since the fixed services charges are high. Additionally, the data collected from smart meters have security and privacy implications for the consumer. These projects failed to consider end-users as an important stakeholder group during planning stages resulting in the design and roll-out of expensive systems, which do not demonstrate clear consumer benefits. The overall goal of the research reported in this thesis was to improve the smart metering system to deliver consumer benefits that increase confidence and acceptance of these projects. The smart metering system was examined from an end-user perspective for realistic insights into consumer concerns. Processes from Design Science Research methodology were utilised to conduct this research due to the utilitarian nature of the objective. Consumer segmentation was central to the proposed measures. Initially, a consumer-friendly risk analysis framework was devised, and appropriate requirement elicitation techniques were identified. Control options for smart meter data transfer and storage were explored. Various scenarios were analysed to determine consumer-friendly features in the smart metering system, including control options for smart meter data transfer and storage. Proposed functionalities (billing choices, feedback information and specific configurations to match the needs of different user segments) were studied using the Australian smart metering system. Smart meters vary in capabilities depending on the manufacturer, mode and place of deployment. The research showed that features proposed in this thesis are implementable in smart meters, by examining their applicability to those used in Victoria (Australia). This study demonstrated that intelligent systems for demand and distribution-side management can be built without the use of detailed consumption data from the consumer. Many issues related to smart meter data could be avoided by distributing intelligent metering devices across the network. A check-list was generated to guide project proponents to achieve a consumer-friendly outcome. This research establishes that by applying well-established theories during the planning process, in particular, requirement elicitation and risk analysis, consumer support can be gained leading to the deployment of user-friendly and sustainable systems. The check-list generated will help the industry to appropriately plan and develop systems that can avoid opposition and even stimulate adoption. Options proposed provide choices for different consumer segments without affecting major operations such as billing. On evaluation, it has been identified that the proposed measures do not affect the quality attributes of the system. Since the proposals presented in this thesis were based on smart meters used in Victoria (Australia), smart meters used in other areas may require upgrades or revisions to support these functions. The scope of this research is limited to identifying improvements in the system that will benefit the residential consumer and does not extend to the analysis of the effects of these improvements on the profitability of the investors.

  6. Pattern mining of user interaction logs for a post-deployment usability evaluation of a radiology PACS client.

    PubMed

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi A; Oudkerk, Matthijs; van Ooijen, Peter M A

    2016-01-01

    To perform a post-deployment usability evaluation of a radiology Picture Archiving and Communication System (PACS) client based on pattern mining of user interaction log data, and to assess the usefulness of this approach compared to a field study. All user actions performed on the PACS client were logged for four months. A data mining technique called closed sequential pattern mining was used to automatically extract frequently occurring interaction patterns from the log data. These patterns were used to identify usability issues with the PACS. The results of this evaluation were compared to the results of a field study based usability evaluation of the same PACS client. The interaction patterns revealed four usability issues: (1) the display protocols do not function properly, (2) the line measurement tool stays active until another tool is selected, rather than being deactivated after one use, (3) the PACS's built-in 3D functionality does not allow users to effectively perform certain 3D-related tasks, (4) users underuse the PACS's customization possibilities. All usability issues identified based on the log data were also found in the field study, which identified 48 issues in total. Post-deployment usability evaluation based on pattern mining of user interaction log data provides useful insights into the way users interact with the radiology PACS client. However, it reveals few usability issues compared to a field study and should therefore not be used as the sole method of usability evaluation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Usability Guidelines for Product Recommenders Based on Example Critiquing Research

    NASA Astrophysics Data System (ADS)

    Pu, Pearl; Faltings, Boi; Chen, Li; Zhang, Jiyong; Viappiani, Paolo

    Over the past decade, our group has developed a suite of decision tools based on example critiquing to help users find their preferred products in e-commerce environments. In this chapter, we survey important usability research work relative to example critiquing and summarize the major results by deriving a set of usability guidelines. Our survey is focused on three key interaction activities between the user and the system: the initial preference elicitation process, the preference revision process, and the presentation of the systems recommendation results. To provide a basis for the derivation of the guidelines, we developed a multi-objective framework of three interacting criteria: accuracy, confidence, and effort (ACE). We use this framework to analyze our past work and provide a specific context for each guideline: when the system should maximize its ability to increase users' decision accuracy, when to increase user confidence, and when to minimize the interaction effort for the users. Due to the general nature of this multi-criteria model, the set of guidelines that we propose can be used to ease the usability engineering process of other recommender systems, especially those used in e-commerce environments. The ACE framework presented here is also the first in the field to evaluate the performance of preference-based recommenders from a user-centric point of view.

  8. LSST system analysis and integration task for an advanced science and application space platform

    NASA Technical Reports Server (NTRS)

    1980-01-01

    To support the development of an advanced science and application space platform (ASASP) requirements of a representative set of payloads requiring large separation distances selected from the Science and Applications Space Platform data base. These payloads were a 100 meter diameter atmospheric gravity wave antenna, a 100 meter by 100 meter particle beam injection experiment, a 2 meter diameter, 18 meter long astrometric telescope, and a 15 meter diameter, 35 meter long large ambient deployable IR telescope. A low earth orbit at 500 km altitude and 56 deg inclination was selected as being the best compromise for meeting payload requirements. Platform subsystems were defined which would support the payload requirements and a physical platform concept was developed. Structural system requirements which included utilities accommodation, interface requirements, and platform strength and stiffness requirements were developed. An attitude control system concept was also described. The resultant ASASP concept was analyzed and technological developments deemed necessary in the area of large space systems were recommended.

  9. A Human Reliability Based Usability Evaluation Method for Safety-Critical Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillippe Palanque; Regina Bernhaupt; Ronald Boring

    2006-04-01

    Recent years have seen an increasing use of sophisticated interaction techniques including in the field of safety critical interactive software [8]. The use of such techniques has been required in order to increase the bandwidth between the users and systems and thus to help them deal efficiently with increasingly complex systems. These techniques come from research and innovation done in the field of humancomputer interaction (HCI). A significant effort is currently being undertaken by the HCI community in order to apply and extend current usability evaluation techniques to these new kinds of interaction techniques. However, very little has been donemore » to improve the reliability of software offering these kinds of interaction techniques. Even testing basic graphical user interfaces remains a challenge that has rarely been addressed in the field of software engineering [9]. However, the non reliability of interactive software can jeopardize usability evaluation by showing unexpected or undesired behaviors. The aim of this SIG is to provide a forum for both researchers and practitioners interested in testing interactive software. Our goal is to define a roadmap of activities to cross fertilize usability and reliability testing of these kinds of systems to minimize duplicate efforts in both communities.« less

  10. A usability assessment on a virtual reality system for panic disorder treatment

    NASA Astrophysics Data System (ADS)

    Lee, Jaelin; Kawai, Takashi; Yoshida, Nahoko; Izawa, Shuhei; Nomura, Shinobu; Eames, Douglas; Kaiya, Hisanobu

    2008-02-01

    The authors have developed a virtual reality exposure system that reflects the Japanese culture and environment. Concretely, the system focuses on the subway environment, which is the environment most patients receiving treatment for panic disorder at hospitals in Tokyo, Japan tend to avoid. The system is PC based and features realistic video images and highly interactive functionality. In particular, the system enables instant transformation of the virtual space and allows situations to be freely customized according to the condition and symptoms expressed by each patient. Positive results achieved in therapy assessments aimed at patients with panic disorder accompanying agoraphobia indicate the possibility of indoor treatment. Full utilization of the functionality available requires that the interactive functions be easily operable. Accordingly, there appears to be a need for usability testing aimed at determining whether or not a therapist can operate the system naturally while focusing fully on treatment. In this paper, the configuration of the virtual reality exposure system focusing on the subway environment is outlined. Further, the results of usability tests aimed at assessing how naturally it can be operated while focusing fully on treatment are described.

  11. Energy Autonomous Wireless Water Meter with Integrated Turbine Driven Energy Harvester

    NASA Astrophysics Data System (ADS)

    Becker, P.; Folkmer, B.; Goepfert, R.; Hoffmann, D.; Willmann, A.; Manoli, Y.

    2013-12-01

    Accurate meter reading is the fundamental task of the home water system for the handling of payments. Meters need to be read correctly, to avoid an effect of adding events that increase unnecessary cost and create customer dissatisfaction. This paper presents a fully integrated wireless, energy autonomous water metering system based on the European Standard EN 13757 "Communication systems for meters and remote reading of meters". The system can be used in multiple water metering scenarios. No maintenance will be required and the system will provide precise and secure data transmission as well as timely and accurate recording of the consumption of water. The identification of any leakages will be improved through the analysis of the actual quantity supplied and recorded by the meters. The system is powered by an energy harvester, based on a water driven turbine wheel that is directly coupled to an electromagnetic energy transducer. The power delivered by the generator is dependent of the amount of flowing water and the pressure in the water pipes. Therefor the power is commonly non-continuous, fluctuant and unstable in the voltage amplitude. To be able to report the meter readings at all times, the system needs to be powered not only in times when the energy harvester delivers energy. Therefor an energy buffer, that stores the harvested energy, is installed to compensate the energy requirement between the actual generator output and the energy consumption of the application. Besides a complete system overview, the presentation will focus on the power management and energy aware battery charging circuitry. The design, fabrication, measuring results and the preparations for field tests in rural and urban environment will be presented and discussed.

  12. A Contextual Model for Identity Management (IdM) Interfaces

    ERIC Educational Resources Information Center

    Fuller, Nathaniel J.

    2014-01-01

    The usability of Identity Management (IdM) systems is highly dependent upon design that simplifies the processes of identification, authentication, and authorization. Recent findings reveal two critical problems that degrade IdM usability: (1) unfeasible techniques for managing various digital identifiers, and (2) ambiguous security interfaces.…

  13. 5 CFR 532.241 - Analysis of usable wage survey data.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... average rates identified and computed under paragraph (a) of this section. (ii) The frequency payline... PREVAILING RATE SYSTEMS Prevailing Rate Determinations § 532.241 Analysis of usable wage survey data. (a)(1) The lead agency shall compute a weighted average rate for each appropriated fund survey job having at...

  14. Scale-up considerations for surface collecting agent assisted in-situ burn crude oil spill response experiments in the Arctic: Laboratory to field-scale investigations.

    PubMed

    Bullock, Robin J; Aggarwal, Srijan; Perkins, Robert A; Schnabel, William

    2017-04-01

    In the event of a marine oil spill in the Arctic, government agencies, industry, and the public have a stake in the successful implementation of oil spill response. Because large spills are rare events, oil spill response techniques are often evaluated with laboratory and meso-scale experiments. The experiments must yield scalable information sufficient to understand the operability and effectiveness of a response technique under actual field conditions. Since in-situ burning augmented with surface collecting agents ("herders") is one of the few viable response options in ice infested waters, a series of oil spill response experiments were conducted in Fairbanks, Alaska, in 2014 and 2015 to evaluate the use of herders to assist in-situ burning and the role of experimental scale. This study compares burn efficiency and herder application for three experimental designs for in-situ burning of Alaska North Slope crude oil in cold, fresh waters with ∼10% ice cover. The experiments were conducted in three project-specific constructed venues with varying scales (surface areas of approximately 0.09 square meters, 9 square meters and 8100 square meters). The results from the herder assisted in-situ burn experiments performed at these three different scales showed good experimental scale correlation and no negative impact due to the presence of ice cover on burn efficiency. Experimental conclusions are predominantly associated with application of the herder material and usability for a given experiment scale to make response decisions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Method and apparatus for reading meters from a video image

    DOEpatents

    Lewis, Trevor J.; Ferguson, Jeffrey J.

    1997-01-01

    A method and system to enable acquisition of data about an environment from one or more meters using video images. One or more meters are imaged by a video camera and the video signal is digitized. Then, each region of the digital image which corresponds to the indicator of the meter is calibrated and the video signal is analyzed to determine the value indicated by each meter indicator. Finally, from the value indicated by each meter indicator in the calibrated region, a meter reading is generated. The method and system offer the advantages of automatic data collection in a relatively non-intrusive manner without making any complicated or expensive electronic connections, and without requiring intensive manpower.

  16. Design of Smart-Meter data acquisition device based on Cloud Platform

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-05-01

    In recent years, the government has attached great importance to ‘Four-Meter Unified’ Project. Under the call of national policy, State Grid is participate in building ‘Four-Meter Unified’ Project actively by making use of electricity information acquisition system. In this paper, a new type Smart-Meter data acquisition device based on Cloud Platform is designed according to the newest series of standards Energy Measure and Management System for Electric, Water, Gas and Heat Meter, and this paper introduces the general scheme, main hardware design and main software design for the Smart-Meter data acquisition device.

  17. Capillary glucose meter accuracy and sources of error in the ambulatory setting.

    PubMed

    Lunt, Helen; Florkowski, Christopher; Bignall, Michael; Budgen, Christopher

    2010-03-05

    Hand-held glucose meters are used throughout the health system by both patients with diabetes and also by health care practitioners. Glucose meter technology is constantly evolving. The current generation of meters and strips are quick to use and require a very small volume of blood. This review aims to describe meters currently available in New Zealand, for use in the ambulatory setting. It also aims to discuss the limits of meter performance and provide technical information that is relevant to the clinician, using locally available data. Commoner causes and consequences of end-user (patient and health professional) error are illustrated using clinical case examples. No meter offers definite advantages over other meters in all clinical situations, rather meters should be chosen because they fit the needs of individual patients and because the provider is able to offer appropriate educational and quality assurance backup to the meter user. A broad understanding of the advantages and disadvantages of the subsidised meter systems available in New Zealand will help the health practitioner decide when it is in the best interests of their patients to change or update meter technology.

  18. 39 CFR 501.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... limited to postage meters and PC Postage systems. (b) A postage meter is a Postal Service-approved Postage... this part refers to a postage meter. (c) PC Postage products are Postal Service-approved Postage Evidencing Systems that use a personal computer as an integral part of the system. PC Postage products may...

  19. Logistical Consideration in Computer-Based Screening of Astronaut Applicants

    NASA Technical Reports Server (NTRS)

    Galarza, Laura

    2000-01-01

    This presentation reviews the logistical, ergonomic, and psychometric issues and data related to the development and operational use of a computer-based system for the psychological screening of astronaut applicants. The Behavioral Health and Performance Group (BHPG) at the Johnson Space Center upgraded its astronaut psychological screening and selection procedures for the 1999 astronaut applicants and subsequent astronaut selection cycles. The questionnaires, tests, and inventories were upgraded from a paper-and-pencil system to a computer-based system. Members of the BHPG and a computer programmer designed and developed needed interfaces (screens, buttons, etc.) and programs for the astronaut psychological assessment system. This intranet-based system included the user-friendly computer-based administration of tests, test scoring, generation of reports, the integration of test administration and test output to a single system, and a complete database for past, present, and future selection data. Upon completion of the system development phase, four beta and usability tests were conducted with the newly developed system. The first three tests included 1 to 3 participants each. The final system test was conducted with 23 participants tested simultaneously. Usability and ergonomic data were collected from the system (beta) test participants and from 1999 astronaut applicants who volunteered the information in exchange for anonymity. Beta and usability test data were analyzed to examine operational, ergonomic, programming, test administration and scoring issues related to computer-based testing. Results showed a preference for computer-based testing over paper-and -pencil procedures. The data also reflected specific ergonomic, usability, psychometric, and logistical concerns that should be taken into account in future selection cycles. Conclusion. Psychological, psychometric, human and logistical factors must be examined and considered carefully when developing and using a computer-based system for psychological screening and selection.

  20. Adapting Nielsen’s Design Heuristics to Dual Processing for Clinical Decision Support

    PubMed Central

    Taft, Teresa; Staes, Catherine; Slager, Stacey; Weir, Charlene

    2016-01-01

    The study objective was to improve the applicability of Nielson’s standard design heuristics for evaluating electronic health record (EHR) alerts and linked ordering support by integrating them with Dual Process theory. Through initial heuristic evaluation and a user study of 7 physicians, usability problems were identified. Through independent mapping of specific usability criteria to support for each of the Dual Cognitive processes (S1 and S2) and deliberation, agreement was reached on mapping criteria. Finally, usability errors from the heuristic and user study were mapped to S1 and S2. Adding a dual process perspective to specific heuristic analysis increases the applicability and relevance of computerized health information design evaluations. This mapping enables designers to measure that their systems are tailored to support attention allocation. System 1 will be supported by improving pattern recognition and saliency, and system 2 through efficiency and control of information access. PMID:28269915

  1. Adapting Nielsen's Design Heuristics to Dual Processing for Clinical Decision Support.

    PubMed

    Taft, Teresa; Staes, Catherine; Slager, Stacey; Weir, Charlene

    2016-01-01

    The study objective was to improve the applicability of Nielson's standard design heuristics for evaluating electronic health record (EHR) alerts and linked ordering support by integrating them with Dual Process theory. Through initial heuristic evaluation and a user study of 7 physicians, usability problems were identified. Through independent mapping of specific usability criteria to support for each of the Dual Cognitive processes (S1 and S2) and deliberation, agreement was reached on mapping criteria. Finally, usability errors from the heuristic and user study were mapped to S1 and S2. Adding a dual process perspective to specific heuristic analysis increases the applicability and relevance of computerized health information design evaluations. This mapping enables designers to measure that their systems are tailored to support attention allocation. System 1 will be supported by improving pattern recognition and saliency, and system 2 through efficiency and control of information access.

  2. Usability of Videogame-Based Dexterity Training in the Early Rehabilitation Phase of Stroke Patients: A Pilot Study.

    PubMed

    Vanbellingen, Tim; Filius, Suzanne J; Nyffeler, Thomas; van Wegen, Erwin E H

    2017-01-01

    Approximately 70-80% of stroke survivors have limited activities of daily living, mainly due to dexterous problems. Videogame-based training (VBT) along with virtual reality seems to be beneficial to train upper limb function. To evaluate the usability of VBT using the Leap Motion Controller (LMC) to train fine manual dexterity in the early rehabilitation phase of stroke patients as an add-on to conventional therapy. Additionally, this study aimed to estimate the feasibility and potential efficacy of the VBT. During 3 months, 64 stroke patients were screened for eligibility, 13 stroke patients were included (4 women and 9 men; age range: 24-91 years; mean time post stroke: 28.2 days). Nine sessions of 30 min VBT, three times per week as an add-on to conventional therapy with stroke inpatients. Primary outcome was the usability of the system measured with the System Usability Scale. Secondary outcomes concerning feasibility were the compliance rate calculated from the total time spent on the intervention (TT) compared to planned time, the opinion of participants via open-end questions, and the level of active participation measured with the Pittsburgh Rehabilitation Participation Scale. Regarding the potential efficacy secondary outcomes were: functional dexterity measured with the Nine Hole Peg Test (NHPT), subjective dexterity measured with the Dexterity Questionnaire 24, grip strength measured with the Jamar dynamometer, and motor impairment of the upper limb measured with the Fugl-Meyer Upper Extremity (FM-UE) scale. Primarily, the usability of the system was good to excellent. The patient's perception of usability remained stable over a mean period of 3 weeks of VBT. Secondly, the compliance rate was good, and the level of active participation varied between good and very good. The opinion of the participants revealed that despite individual differences, the overall impression of the therapy and device was good. Patients showed significant improvements in hand dexterity. No changes were found in motor impairment of the upper limb (FM-UE) during intervention. VBT using LMC is a usable rehabilitation tool to train dexterity in the early rehabilitation phase of stroke inpatients.

  3. DSN 63 64-meter antenna S- and X-band efficiency and system noise temperature calibrations, July 1986

    NASA Technical Reports Server (NTRS)

    Slobin, S. D.

    1987-01-01

    The Deep Space Network (DSN) 64-meter antenna in Spain (DSN 63) has been calibrated prior to its upgrading to a 70-meter high efficiency configuration in preparation for the Voyager Neptune encounter in August 1989. The S-band (2285 MHz) and X-band (8420 MHz) effective area efficiency and system noise temperature calibrations were carried out during July 1986 to establish a baseline system performance for this station. It is expected that the 70-meter will result in at least a 1.9 dB G/T improvement at X-band relative to the 64-meter baseline reference.

  4. [Exploring nurse, usage effectiveness of mobile nursing station].

    PubMed

    Chang, Fang-Mei; Lee, Ting-Ting

    2013-04-01

    A mobile nursing station is an innovative cart that integrates a wireless network, information technology devices, and online charts. In addition to improving clinical work and workflow efficiencies, data is integrated among different information systems and hardware devices to promote patient safety. This study investigated the effectiveness of mobile nursing cart use. We compared different distributions of nursing activity working samples to evaluate the nursing information systems in terms of interface usability and usage outcomes. There were two parts of this study. Part one used work sampling to collect nursing activity data necessary to compare a unit that used a mobile nursing cart (mobile group, n = 18) with another that did not (traditional group, n = 14). Part two applied a nursing information system interface usability questionnaire to survey the mobile unit with nurses who had used a mobile nursing station (including those who had worked in this unit as floating nurses) (n = 30) in order to explore interface usability and effectiveness. We found that using the mobile nursing station information system increased time spent on direct patient care and decreased time spent on indirect patient care and documentation. Results further indicated that participants rated interface usability as high and evaluated usage effectiveness positively. Comments made in the open-ended question section raised several points of concern, including problems / inadequacies related to hardware devices, Internet speed, and printing. This study indicates that using mobile nursing station can improve nursing activity distributions and that nurses hold generally positive attitudes toward mobile nursing station interface usability and usage effectiveness. The authors thus encourage the continued implementation of mobile nursing stations and related studies to further enhance clinical nursing care.

  5. Evaluation of the acceptability and usability of a decision support system to encourage safe and effective use of opioid therapy for chronic, noncancer pain by primary care providers.

    PubMed

    Trafton, Jodie; Martins, Susana; Michel, Martha; Lewis, Eleanor; Wang, Dan; Combs, Ann; Scates, Naquell; Tu, Samson; Goldstein, Mary K

    2010-04-01

    To develop and evaluate a clinical decision support system (CDSS) named Assessment and Treatment in Healthcare: Evidenced-Based Automation (ATHENA)-Opioid Therapy, which encourages safe and effective use of opioid therapy for chronic, noncancer pain. CDSS development and iterative evaluation using the analysis, design, development, implementation, and evaluation process including simulation-based and in-clinic assessments of usability for providers followed by targeted system revisions. Volunteers provided detailed feedback to guide improvements in the graphical user interface, and content and design changes to increase clinical usefulness, understandability, clinical workflow fit, and ease of completing guideline recommended practices. Revisions based on feedback increased CDSS usability ratings over time. Practice concerns outside the scope of the CDSS were also identified. Usability testing optimized the CDSS to better address barriers such as lack of provider education, confusion in dosing calculations and titration schedules, access to relevant patient information, provider discontinuity, documentation, and access to validated assessment tools. It also highlighted barriers to good clinical practice that are difficult to address with CDSS technology in its current conceptualization. For example, clinicians indicated that constraints on time and competing priorities in primary care, discomfort in patient-provider communications, and lack of evidence to guide opioid prescribing decisions impeded their ability to provide effective, guideline-adherent pain management. Iterative testing was essential for designing a highly usable and acceptable CDSS; however, identified barriers may limit the impact of the ATHENA-Opioid Therapy system and other CDSS on clinical practices and outcomes unless CDSS are paired with parallel initiatives to address these issues.

  6. Preliminary Evaluation of a Personal Healthcare System Prototype for Cognitive eRehabilitation in a Living Assistance Domain

    PubMed Central

    Pastorino, Matteo; Fioravanti, Alessio; Arredondo, Maria Teresa; Cogollor, José M.; Rojo, Javier; Ferre, Manuel; Bienkiewicz, Marta; Hermsdörfer, Joachim; Fringi, Evangelia; Wing, Alan M.

    2014-01-01

    The integration of rehabilitation systems in an ambient assisted living environment can provide a powerful and versatile tool for long-term stroke rehabilitation goals. This paper introduces a novel concept of a personalized cognitive rehabilitation system in a naturalistic setting. The proposed platform was developed within the CogWatch project, with the intent of fostering independence in activities of daily living in patients with apraxia and action disorganization syndrome. Technical usability was evaluated in a series of pilot experiments, which illustrate how this approach may help to retrain patients in activities of daily living. The first system prototype has been tested with 36 participants divided into three groups, providing an exploratory evaluation of the usability of this solution and its acceptability. The technical solutions used within the CogWatch project are targeted to meet both the end users' needs from the interaction and usability point of views and the clinical requirements associated with the use of such systems. The challenges behind the development of ambient assisted living systems for cognitive rehabilitation are discussed. PMID:24922452

  7. Usability evaluation of mobile applications using ISO 9241 and ISO 25062 standards.

    PubMed

    Moumane, Karima; Idri, Ali; Abran, Alain

    2016-01-01

    This paper presents an empirical study based on a set of measures to evaluate the usability of mobile applications running on different mobile operating systems, including Android, iOS and Symbian. The aim is to evaluate empirically a framework that we have developed on the use of the Software Quality Standard ISO 9126 in mobile environments, especially the usability characteristic. To do that, 32 users had participated in the experiment and we have used ISO 25062 and ISO 9241 standards for objective measures by working with two widely used mobile applications: Google Apps and Google Maps. The QUIS 7.0 questionnaire have been used to collect measures assessing the users' level of satisfaction when using these two mobile applications. By analyzing the results we highlighted a set of mobile usability issues that are related to the hardware as well as to the software and that need to be taken into account by designers and developers in order to improve the usability of mobile applications.

  8. Feasibility and usability of a home monitoring concept based on mobile phones and near field communication (NFC) technology.

    PubMed

    Morak, Jürgen; Kollmann, Alexander; Schreier, Günter

    2007-01-01

    Utilization of mobile information and communication technologies in home monitoring applications is becoming more and more common. The mobile phone, acting as a patient terminal for patients suffering from chronic diseases, provides an active link to the caregiver to transmit health status information and receive feedback. In such a concept the usability is still limited by the necessity of entering the values via the mobile phone's small keypad. The near field communication technology (NFC), a touch-based wireless interface that became available recently, may improve the usability level of such applications significantly. The focus of this paper is to describe the development of a prototype application based on this technology embedded in a home monitoring system. The feasibility and usability of this approach are evaluated and compared with concepts used in previous approaches. The high quantifier with respect to overall usability indicates that NFC may be the technology of choice for some tasks in home monitoring applications.

  9. Usability evaluation of user interface of thesis title review system

    NASA Astrophysics Data System (ADS)

    Tri, Y.; Erna, A.; Gellysa, U.

    2018-03-01

    Presentation of programs with user interface that can be accessed online through the website of course greatly provide user benefits. User can easily access the program they need. There are usability values that serve as a benchmark for the success of a user accessible program, ie efficiency, effectiveness, and convenience. These usability values also determine the development of the program for the better use. Therefore, on the review title thesis program that will be implemented in STT Dumai was measured usability evaluation. It aims to see which sides are not yet perfect and need to be improved to improve the performance and utilization of the program. Usability evaluation was measured by using smartPLS software. Database used was the result of respondent questionnaires that include questions about the experience when they used program. The result of a review of thesis title program implemented in STT Dumai has an efficiency value of 22.615, the effectiveness of 20.612, and satisfaction of 33.177.

  10. The McMaster Optimal Aging Portal: Usability Evaluation of a Unique Evidence-Based Health Information Website.

    PubMed

    Barbara, Angela M; Dobbins, Maureen; Haynes, R Brian; Iorio, Alfonso; Lavis, John N; Raina, Parminder; Levinson, Anthony J

    2016-05-11

    Increasingly, older adults and their informal caregivers are using the Internet to search for health-related information. There is a proliferation of health information online, but the quality of this information varies, often based on exaggerated or dramatic findings, and not easily comprehended by consumers. The McMaster Optimal Aging Portal (Portal) was developed to provide Internet users with high-quality evidence about aging and address some of these current limitations of health information posted online. The Portal includes content for health professionals coming from three best-in-class resources (MacPLUS, Health Evidence, and Health Systems Evidence) and four types of content specifically prepared for the general public (Evidence Summaries, Web Resource Ratings, Blog Posts, and Twitter messages). Our objectives were to share the findings of the usability evaluation of the Portal with particular focus on the content features for the general public and to inform designers of health information websites and online resources for older adults about key usability themes. Data analysis included task performance during usability testing and qualitative content analyses of both the usability sessions and interviews to identify core themes. A total of 37 participants took part in 33 usability testing sessions and 21 focused interviews. Qualitative analysis revealed common themes regarding the Portal's strengths and challenges to usability. The strengths of the website were related to credibility, applicability, browsing function, design, and accessibility. The usability challenges included reluctance to register, process of registering, searching, terminology, and technical features. The study reinforced the importance of including end users during the development of this unique, dynamic, evidence-based health information website. The feedback was applied to iteratively improve website usability. Our findings can be applied by designers of health-related websites.

  11. The McMaster Optimal Aging Portal: Usability Evaluation of a Unique Evidence-Based Health Information Website

    PubMed Central

    Dobbins, Maureen; Haynes, R. Brian; Iorio, Alfonso; Lavis, John N; Raina, Parminder

    2016-01-01

    Background Increasingly, older adults and their informal caregivers are using the Internet to search for health-related information. There is a proliferation of health information online, but the quality of this information varies, often based on exaggerated or dramatic findings, and not easily comprehended by consumers. The McMaster Optimal Aging Portal (Portal) was developed to provide Internet users with high-quality evidence about aging and address some of these current limitations of health information posted online. The Portal includes content for health professionals coming from three best-in-class resources (MacPLUS, Health Evidence, and Health Systems Evidence) and four types of content specifically prepared for the general public (Evidence Summaries, Web Resource Ratings, Blog Posts, and Twitter messages). Objective Our objectives were to share the findings of the usability evaluation of the Portal with particular focus on the content features for the general public and to inform designers of health information websites and online resources for older adults about key usability themes. Methods Data analysis included task performance during usability testing and qualitative content analyses of both the usability sessions and interviews to identify core themes. Results A total of 37 participants took part in 33 usability testing sessions and 21 focused interviews. Qualitative analysis revealed common themes regarding the Portal’s strengths and challenges to usability. The strengths of the website were related to credibility, applicability, browsing function, design, and accessibility. The usability challenges included reluctance to register, process of registering, searching, terminology, and technical features. Conclusions The study reinforced the importance of including end users during the development of this unique, dynamic, evidence-based health information website. The feedback was applied to iteratively improve website usability. Our findings can be applied by designers of health-related websites. PMID:27170443

  12. Experiments with Coler magnetic current apparatus

    NASA Astrophysics Data System (ADS)

    Ludwig, T.

    Experiments with a replica of the famous Coler "Magnetstromapparat" (magnetic current apparatus) were conducted. The replica was built at the same institute at the Technical University of Berlin where the original was tested by Prof. Kloss in 1925. The details of the setup will be presented in this paper. The investigation of the Coler device was done with modern methods. The output was measured with a digital multi meter (DMM) and a digital storage oscilloscope (DSO). The results of the measurements will be presented. Did Coler convert vacuum fluctuations via magnetic, electric and acoustic resonance into electricity? There is a strong connection between magnetism and quantum field radiation energy. The magnetic moment of the electron is in part an energy exchange with the radiation field. The energy output of the Coler apparatus is measured. Furthermore the dynamics of the ferromagnetic magnets that Coler reported as the working principle of his device was investigated with magnetic force microscopy (MFM) and the spectroscopy mode of an atomic force microscope (AFM). The magnetic and acoustic resonance was investigated with magnetic force microscopy (MFM). The connection between ZPE and magnetism will be discussed as well as the perspective of using magnetic systems as a means to convert vacuum fluctuations into usable electricity.

  13. A Mobile App (BEDSide Mobility) to Support Nurses’ Tasks at the Patient's Bedside: Usability Study

    PubMed Central

    Weinhold, Thomas; Joe, Jonathan; Lovis, Christian; Blondon, Katherine

    2018-01-01

    Background The introduction of clinical information systems has increased the amount of clinical documentation. Although this documentation generally improves patient safety, it has become a time-consuming task for nurses, which limits their time with the patient. On the basis of a user-centered methodology, we have developed a mobile app named BEDSide Mobility to support nurses in their daily workflow and to facilitate documentation at the bedside. Objective The aim of the study was to assess the usability of the BEDSide Mobility app in terms of the navigation and interaction design through usability testing. Methods Nurses were asked to complete a scenario reflecting their daily work with patients. Their interactions with the app were captured with eye-tracking glasses and by using the think aloud protocol. After completing the tasks, participants filled out the system usability scale questionnaire. Descriptive statistics were used to summarize task completion rates and the users’ performance. Results A total of 10 nurses (aged 21-50) participated in the study. Overall, they were satisfied with the navigation, layout, and interaction design of the app, with the exception of one user who was unfamiliar with smartphones. The problems identified were related to the ambiguity of some icons, the navigation logic, and design inconsistency. Conclusions Besides the usability issues identified in the app, the participants’ results do indicate good usability, high acceptance, and high satisfaction with the developed app. However, the results must be taken with caution because of the poor ecological validity of the experimental setting. PMID:29563074

  14. Information Metering: Paving the Way for Pay-per-View Information.

    ERIC Educational Resources Information Center

    Hawkins, Donald T.

    1996-01-01

    Describes information metering technology as a method that information providers use to provide information collections to users in encrypted form and charge them only for the parts actually used. Discusses how two current information metering systems (Wave Systems Corporation and CD-MAX) operate, the institutions using their systems, and the…

  15. 24 CFR 965.407 - Reevaluations of master-meter systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Reevaluations of master-meter systems. 965.407 Section 965.407 Housing and Urban Development REGULATIONS RELATING TO HOUSING AND URBAN... Existing PHA-Owned Projects § 965.407 Reevaluations of master-meter systems. Because of changes in the cost...

  16. TRL Assessment of Solar Sail Technology Development Following the 20-Meter System Ground Demonstrator Hardware Testing

    NASA Technical Reports Server (NTRS)

    Young, Roy M.; Adams, Charles L.

    2010-01-01

    The NASA In-Space Propulsion Technology (ISPT) Projects Office sponsored two separate, independent solar sail system design and development demonstration activities during 2002-2005. ATK Space Systems of Goleta, CA was the prime contractor for one development team and L' Garde, Inc. of Tustin, CA was the prime contractor for the other development team. The goal of these activities was to advance the technology readiness level (TRL) of solar sail propulsion from 3 towards 6 by the year 2006. Component and subsystem fabrication and testing were completed successfully, including the ground deployment of 10-meter and 20-meter demonstration hardware systems under vacuum conditions. The deployment and structural testing of the 20-meter solar sail systems was conducted in the 30 meter diameter Space Power Facility thermal-vacuum chamber at NASA Glenn Plum Brook in April though August, 2005. This paper will present the results of the TRL assessment following the solar sail technology development activities associated with the design, development, analysis and testing of the 20-meter system ground demonstrators.

  17. Method and apparatus for reading meters from a video image

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, T.J.; Ferguson, J.J.

    1995-12-31

    A method and system enable acquisition of data about an environment from one or more meters using video images. One or more meters are imaged by a video camera and the video signal is digitized. Then, each region of the digital image which corresponds to the indicator of the meter is calibrated and the video signal is analyzed to determine the value indicated by each meter indicator. Finally, from the value indicated by each meter indicator in the calibrated region, a meter reading is generated. The method and system offer the advantages of automatic data collection in a relatively non-intrusivemore » manner without making any complicated or expensive electronic connections, and without requiring intensive manpower.« less

  18. Method and apparatus for reading meters from a video image

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, T.J.; Ferguson, J.J.

    1997-09-30

    A method and system to enable acquisition of data about an environment from one or more meters using video images. One or more meters are imaged by a video camera and the video signal is digitized. Then, each region of the digital image which corresponds to the indicator of the meter is calibrated and the video signal is analyzed to determine the value indicated by each meter indicator. Finally, from the value indicated by each meter indicator in the calibrated region, a meter reading is generated. The method and system offer the advantages of automatic data collection in a relativelymore » non-intrusive manner without making any complicated or expensive electronic connections, and without requiring intensive manpower. 1 fig.« less

  19. Research on the full life cycle management system of smart electric energy meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; Guo, Dingying; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Renheng, Xu

    2018-02-01

    At present, China’s smart electric energy meter life management is started from the procurement and acceptance. The related monitoring and management of the manufacturing sector has not yet been carried out. This article applies RFID technology and network cloud platform to full life cycle management system of smart electric energy meters, builds this full life cycle management system including design and manufacturing, process control, measurement and calibration testing, storage management, user acceptance, site operation, maintenance scrap and other aspects. Exploring smart electric energy meters on-line and off-line communication by the application of active RFID communication functions, and the actual functional application such as local data exchange and instrument calibration. This system provides technical supports on power demand side management and the improvement of smart electric energy meter reliability evaluation system.

  20. Measuring Usability Compliance of a Stand-Alone Educational Tablet: The Users' Perspective, Nigeria

    ERIC Educational Resources Information Center

    Tijani, Olawale Kazeem

    2017-01-01

    This study assessed usability compliance of Opón-Ìmò Technology Enhanced Learning System (OTELS), Nigeria. Specifically, the study investigated: students' satisfaction with the OTELS; its efficiency; retentiveness; learnability and capacity to reduce errors. Being a survey study, samples were drawn from six secondary schools across the three…

  1. The Role of Human Web Assistants in E-Commerce: An Analysis and a Usability Study.

    ERIC Educational Resources Information Center

    Aberg, Johan; Shahmehri, Nahid

    2000-01-01

    Discusses electronic commerce and presents the concept of Web assistants, human assistants working in an electronic Web shop. Presents results of a usability study of a prototype adaptive Web assistant system that show users were enthusiastic about the concept of Web assistants and its implications. (Author/LRW)

  2. Eliciting and Analyzing Quality Requirements: Management Influences on Software Quality Requirements

    DTIC Science & Technology

    2005-03-01

    their portable devices [ Balfanz 04] can be applied to many of the quality requirements issues within the development life cycle: " Neither usability or...Systems. New York, NY: Wiley Computer Publishing, 2001. [ Balfanz 04] Balfanz , D.; Durfee, G; & Smetters, D. K. "Search of Usable Security: Five Lessons from

  3. Usability Evaluation of a Research Repository and Collaboration Web Site

    ERIC Educational Resources Information Center

    Zhang, Tao; Maron, Deborah J.; Charles, Christopher C.

    2013-01-01

    This article reports results from an empirical usability evaluation of Human-Animal Bond Research Initiative Central as part of the effort to develop an open access research repository and collaboration platform for human-animal bond researchers. By repurposing and altering key features of the original HUBzero system, Human-Animal Bond Research…

  4. Defining Usability Heuristics for Adoption and Efficiency of an Electronic Workflow Document Management System

    ERIC Educational Resources Information Center

    Fuentes, Steven

    2017-01-01

    Usability heuristics have been established for different uses and applications as general guidelines for user interfaces. These can affect the implementation of industry solutions and play a significant role regarding cost reduction and process efficiency. The area of electronic workflow document management (EWDM) solutions, also known as…

  5. Graphical Weather Information System Evaluation: Usability, Perceived Utility, and Preferences from General Aviation Pilots

    NASA Technical Reports Server (NTRS)

    Latorella, Kara A.; Chamberlain, James P.

    2002-01-01

    Weather is a significant factor in General Aviation (GA) accidents and fatality rates. Graphical Weather Information Systems (GWISs) for the flight deck are appropriate technologies for mitigating the difficulties GA pilots have with current aviation weather information sources. This paper describes usability evaluations of a prototype GWIS by 12 GA pilots after using the system in flights towards convective weather. We provide design guidance for GWISs and discuss further research required to support weather situation awareness and in-flight decision making for GA pilots.

  6. Effect of improving the usability of an e-learning resource: a randomized trial.

    PubMed

    Davids, Mogamat Razeen; Chikte, Usuf M E; Halperin, Mitchell L

    2014-06-01

    Optimizing the usability of e-learning materials is necessary to reduce extraneous cognitive load and maximize their potential educational impact. However, this is often neglected, especially when time and other resources are limited. We conducted a randomized trial to investigate whether a usability evaluation of our multimedia e-learning resource, followed by fixing of all problems identified, would translate into improvements in usability parameters and learning by medical residents. Two iterations of our e-learning resource [version 1 (V1) and version 2 (V2)] were compared. V1 was the first fully functional version and V2 was the revised version after all identified usability problems were addressed. Residents in internal medicine and anesthesiology were randomly assigned to one of the versions. Usability was evaluated by having participants complete a user satisfaction questionnaire and by recording and analyzing their interactions with the application. The effect on learning was assessed by questions designed to test the retention and transfer of knowledge. Participants reported high levels of satisfaction with both versions, with good ratings on the System Usability Scale and adjective rating scale. In contrast, analysis of video recordings revealed significant differences in the occurrence of serious usability problems between the two versions, in particular in the interactive HandsOn case with its treatment simulation, where there was a median of five serious problem instances (range: 0-50) recorded per participant for V1 and zero instances (range: 0-1) for V2 (P < 0.001). There were no differences in tests of retention or transfer of knowledge between the two versions. In conclusion, usability evaluation followed by a redesign of our e-learning resource resulted in significant improvements in usability. This is likely to translate into improved motivation and willingness to engage with the learning material. In this population of relatively high-knowledge participants, learning scores were similar across the two versions. Copyright © 2014 The American Physiological Society.

  7. Effect of improving the usability of an e-learning resource: a randomized trial

    PubMed Central

    Chikte, Usuf M. E.; Halperin, Mitchell L.

    2014-01-01

    Optimizing the usability of e-learning materials is necessary to reduce extraneous cognitive load and maximize their potential educational impact. However, this is often neglected, especially when time and other resources are limited. We conducted a randomized trial to investigate whether a usability evaluation of our multimedia e-learning resource, followed by fixing of all problems identified, would translate into improvements in usability parameters and learning by medical residents. Two iterations of our e-learning resource [version 1 (V1) and version 2 (V2)] were compared. V1 was the first fully functional version and V2 was the revised version after all identified usability problems were addressed. Residents in internal medicine and anesthesiology were randomly assigned to one of the versions. Usability was evaluated by having participants complete a user satisfaction questionnaire and by recording and analyzing their interactions with the application. The effect on learning was assessed by questions designed to test the retention and transfer of knowledge. Participants reported high levels of satisfaction with both versions, with good ratings on the System Usability Scale and adjective rating scale. In contrast, analysis of video recordings revealed significant differences in the occurrence of serious usability problems between the two versions, in particular in the interactive HandsOn case with its treatment simulation, where there was a median of five serious problem instances (range: 0–50) recorded per participant for V1 and zero instances (range: 0–1) for V2 (P < 0.001). There were no differences in tests of retention or transfer of knowledge between the two versions. In conclusion, usability evaluation followed by a redesign of our e-learning resource resulted in significant improvements in usability. This is likely to translate into improved motivation and willingness to engage with the learning material. In this population of relatively high-knowledge participants, learning scores were similar across the two versions. PMID:24913451

  8. Study on the system-level test method of digital metering in smart substation

    NASA Astrophysics Data System (ADS)

    Zhang, Xiang; Yang, Min; Hu, Juan; Li, Fuchao; Luo, Ruixi; Li, Jinsong; Ai, Bing

    2017-03-01

    Nowadays, the test methods of digital metering system in smart substation are used to test and evaluate the performance of a single device, but these methods can only effectively guarantee the accuracy and reliability of the measurement results of a digital metering device in a single run, it does not completely reflect the performance when each device constitutes a complete system. This paper introduced the shortages of the existing test methods. A system-level test method of digital metering in smart substation was proposed, and the feasibility of the method was proved by the actual test.

  9. Locating and Searching Electronic Documents: A User Study of Supply Publications in the United States Marine Corps

    DTIC Science & Technology

    2007-12-01

    Boyle, “Important issues in hypertext documentation usability,” In Proceedings of the 9th Annual international Conference on Systems Documentation...Tufte’s principles of information design to creating effective Web sites.” In Proceedings of the 15th Annual international Conference on Computer...usability,” In Proceedings of the 9th Annual international Conference on Systems Documentation (Chicago, Illinois, 1991). SIGDOC 󈨟. ACM, New York, NY

  10. Redesigning printed educational materials for primary care physicians: design improvements increase usability.

    PubMed

    Grudniewicz, Agnes; Bhattacharyya, Onil; McKibbon, K Ann; Straus, Sharon E

    2015-11-04

    Printed educational materials (PEMs) are a frequently used tool to disseminate clinical information and attempt to change behavior within primary care. However, their effect on clinician behavior is limited. In this study, we explored how PEMs can be redesigned to better meet the needs of primary care physicians (PCPs) and whether usability and selection can be increased when design principles and user preferences are used. We redesigned a publicly available PEM using physician preferences, design principles, and graphic designer support. We invited PCPs to select their preferred document between the redesigned and original versions in a discrete choice experiment, followed by an assessment of usability with the System Usability Scale and a think aloud process. We conducted this study in both a controlled and opportunistic setting to determine whether usability testing results vary by study location. Think aloud data was thematically analyzed, and results were interpreted using the Technology Acceptance Model. One hundred and eighty four PCPs participated in the discrete choice experiment at the 2014 Family Medicine Forum, a large Canadian conference for family physicians. Of these, 87.7 % preferred the redesigned version. Follow-up interviews were held with a randomly selected group of seven participants. We repeated this in a controlled setting in Toronto, Canada, with a set of 14 participants. Using the System Usability Scale, we found that usability scores were significantly increased with the redesign (p < 0.001). We also found that when PCPs were given the choice between the two versions, they selected the redesigned version as their preferred PEM more often than the original (p < 0.001). Results did not appear to differ between the opportunistic and controlled setting. We used the results of the think aloud process to add to a list of end user preferences developed in a previous study. We found that redesigning a PEM with user preferences and design principles can improve its usability and result in the PEM being selected more often than the original. We feel this finding supports the involvement of the user, application of design principles, and the assistance of a graphic designer in the development of PEMs.

  11. Evaluation of the Acoustic Doppler Velocity Meter for Computation of Discharge Records at Three Sites in Colorado, 2004-2005

    USGS Publications Warehouse

    Stevens, Michael R.; Diaz, Paul; Smits, Dennis E.

    2008-01-01

    The U.S. Geological Survey (USGS), in cooperation with the Colorado Water Conservation Board, conducted a study in 2004-2005 at three sites in Colorado: Bear Creek at Morrison, Clear Creek near Empire, and Redlands Canal near Grand Junction. The study was done to evaluate acoustic Doppler velocity meter (ADVM) technology in different hydrologic settings that are characteristic of many Colorado streamflow-gaging sites. ADVMs have been tested and used extensively in many parts of the United States by USGS but not in Colorado where relatively small, shallow, clear, coarse-bed streams that ice up in the winter may affect the ADVM suitability. In this study, ADVM instrumentation was successfully used and discharge computations compared favorably, generally within 5 to 10 percent, with conventional USGS stage/discharge methods at the three Colorado sites. However, two factors, encountered in this study, may adversely affect the use of ADVM technology in Colorado. First, for some streams, the depth required (about 1.5 feet for a side-looking instrument) cannot be met during low-flow periods of the year. Second, cold temperatures and freezing-thawing cycles can produce ice effects that could prevent collection of usable ADVM (and stage) data.

  12. 76 FR 4097 - Verdant Power, LLC (Verdant); Notice of Application Tendered for Filing With the Commission and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-24

    ... facilities would include: (1) Three 35-kilowatt (kW), 5-meter-diameter axial flow Kinetic System turbine...; (2) nine additional 5-meter-diameter axial flow Kinetic System turbine generator units mounted on...-meter-diameter axial flow Kinetic System turbine generator units mounted on six triframe mounts, with a...

  13. Usability testing in medical informatics: cognitive approaches to evaluation of information systems and user interfaces.

    PubMed Central

    Kushniruk, A. W.; Patel, V. L.; Cimino, J. J.

    1997-01-01

    This paper describes an approach to the evaluation of health care information technologies based on usability engineering and a methodological framework from the study of medical cognition. The approach involves collection of a rich set of data including video recording of health care workers as they interact with systems, such as computerized patient records and decision support tools. The methodology can be applied in the laboratory setting, typically involving subjects "thinking aloud" as they interact with a system. A similar approach to data collection and analysis can also be extended to study of computer systems in the "live" environment of hospital clinics. Our approach is also influenced from work in the area of cognitive task analysis, which aims to characterize the decision making and reasoning of subjects of varied levels of expertise as they interact with information technology in carrying out representative tasks. The stages involved in conducting cognitively-based usability analyses are detailed and the application of such analysis in the iterative process of system and interface development is discussed. PMID:9357620

  14. Usability Assessment of Secure Messaging for Clinical Document Sharing between Health Care Providers and Patients.

    PubMed

    Jahn, Michelle A; Porter, Brian W; Patel, Himalaya; Zillich, Alan J; Simon, Steven R; Russ, Alissa L

    2018-04-01

     Web-based patient portals feature secure messaging systems that enable health care providers and patients to communicate information. However, little is known about the usability of these systems for clinical document sharing.  This article evaluates the usability of a secure messaging system for providers and patients in terms of its ability to support sharing of electronic clinical documents.  We conducted usability testing with providers and patients in a human-computer interaction laboratory at a Midwestern U.S. hospital. Providers sent a medication list document to a fictitious patient via secure messaging. Separately, patients retrieved the clinical document from a secure message and returned it to a fictitious provider. We collected use errors, task completion, task time, and satisfaction.  Twenty-nine individuals participated: 19 providers (6 physicians, 6 registered nurses, and 7 pharmacists) and 10 patients. Among providers, 11 (58%) attached and sent the clinical document via secure messaging without requiring assistance, in a median (range) of 4.5 (1.8-12.7) minutes. No patients completed tasks without moderator assistance. Patients accessed the secure messaging system within 3.6 (1.2-15.0) minutes; retrieved the clinical document within 0.8 (0.5-5.7) minutes; and sent the attached clinical document in 6.3 (1.5-18.1) minutes. Although median satisfaction ratings were high, with 5.8 for providers and 6.0 for patients (scale, 0-7), we identified 36 different use errors. Physicians and pharmacists requested additional features to support care coordination via health information technology, while nurses requested features to support efficiency for their tasks.  This study examined the usability of clinical document sharing, a key feature of many secure messaging systems. Our results highlight similarities and differences between provider and patient end-user groups, which can inform secure messaging design to improve learnability and efficiency. The observations suggest recommendations for improving the technical aspects of secure messaging for clinical document sharing. Schattauer GmbH Stuttgart.

  15. The usability axiom of medical information systems.

    PubMed

    Pantazi, Stefan V; Kushniruk, Andre; Moehr, Jochen R

    2006-12-01

    In this article we begin by connecting the concept of simplicity of user interfaces of information systems with that of usability, and the concept of complexity of the problem-solving in information systems with the concept of usefulness. We continue by stating "the usability axiom" of medical information technology: information systems must be, at the same time, usable and useful. We then try to show why, given existing technology, the axiom is a paradox and we continue with analysing and reformulating it several times, from more fundamental information processing perspectives. We underline the importance of the concept of representation and demonstrate the need for context-dependent representations. By means of thought experiments and examples, we advocate the need for context-dependent information processing and argue for the relevance of algorithmic information theory and case-based reasoning in this context. Further, we introduce the notion of concept spaces and offer a pragmatic perspective on context-dependent representations. We conclude that the efficient management of concept spaces may help with the solution to the medical information technology paradox. Finally, we propose a view of informatics centred on the concepts of context-dependent information processing and management of concept spaces that aligns well with existing knowledge centric definitions of informatics in general and medical informatics in particular. In effect, our view extends M. Musen's proposal and proposes a definition of Medical Informatics as context-dependent medical information processing. The axiom that medical information systems must be, at the same time, useful and usable, is a paradox and its investigation by means of examples and thought experiments leads to the recognition of the crucial importance of context-dependent information processing. On the premise that context-dependent information processing equates to knowledge processing, this view defines Medical Informatics as a context-dependent medical information processing which aligns well with existing knowledge centric definitions of our field.

  16. 40 CFR 92.111 - Smoke measurement system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... system of the light extinction meter, as follows: ER16AP98.000 (b) Equipment. The following equipment... the exhaust plume as it passes through the optical unit. (3) Smokemeter, (light extinction meter). A... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  17. 40 CFR 92.111 - Smoke measurement system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... system of the light extinction meter, as follows: ER16AP98.000 (b) Equipment. The following equipment... the exhaust plume as it passes through the optical unit. (3) Smokemeter, (light extinction meter). A... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  18. 40 CFR 92.111 - Smoke measurement system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system of the light extinction meter, as follows: ER16AP98.000 (b) Equipment. The following equipment... the exhaust plume as it passes through the optical unit. (3) Smokemeter, (light extinction meter). A... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  19. 40 CFR 92.111 - Smoke measurement system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system of the light extinction meter, as follows: ER16AP98.000 (b) Equipment. The following equipment... the exhaust plume as it passes through the optical unit. (3) Smokemeter, (light extinction meter). A... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  20. 40 CFR 92.111 - Smoke measurement system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... system of the light extinction meter, as follows: ER16AP98.000 (b) Equipment. The following equipment... the exhaust plume as it passes through the optical unit. (3) Smokemeter, (light extinction meter). A... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  1. Multicenter User Evaluation of ACCU-CHEK® Combo, an Integrated System for Continuous Subcutaneous Insulin Infusion

    PubMed Central

    Kerr, David; Hoogma, Roel P.L.M; Buhr, Andreas; Petersen, Bettina; Storms, Fred E.M.G

    2010-01-01

    Background The aim of this study was to evaluate a newly developed system for insulin delivery incorporating a multifunctional blood glucose meter and a remotely controlled insulin pump (ACCU-CHEK® Combo system) in established pump users with type 1 diabetes. The technology was assessed both from device performance and subject usability perspectives. Method A multicenter, prospective, single group study was carried out in five centers in the Netherlands and four centers in the United Kingdom for more than 6 months. The study was divided into two phases: Phase 1 (4 weeks) for device validation purposes and phase 2 (22 weeks) to observe the impact of the system on metabolic control, patient satisfaction [using the Diabetes Treatment Satisfaction Questionnaire (DTSQ)] and device safety. Results Eighty subjects completed the planned study period. There were no unexpected device errors. Treatment satisfaction was high at baseline and further increased to study end (DTSQ change version: sum score, 10.6 ± 7.2; scale score range, -18 to +18, p < 0.0001). Hemoglobin A1c improved continuously over time, from 7.9% (±0.9%) to 7.7% (±0.8%) at month 3 (p < 0.001) and 7.6% (±0.8%) at month 6 (p < 0.0001). The frequency of severe hypoglycemia was 0.08 per patient years. There was no case of ketoacidosis. Conclusions The new system was evaluated by experienced continuous subcutaneous insulin infusion users as safe in daily practice and associated with favorable treatment satisfaction and a modest improvement in glycemic control. PMID:21129336

  2. User-Centered Innovation: A Model for "Early Usability Testing."

    ERIC Educational Resources Information Center

    Sugar, William A.; Boling, Elizabeth

    The goal of this study is to show how some concepts and techniques from disciplines outside Instructional Systems Development (ISD) have the potential to extend and enhance the traditional view of ISD practice when they are employed very early in the ISD process. The concepts and techniques employed were user-centered in design and usability, and…

  3. Towards an Understanding of Mobile Website Contextual Usability and Its Impact on Mobile Commerce

    ERIC Educational Resources Information Center

    Hyman, Jack Alan

    2012-01-01

    An increasing number of technologies and applications have begun to focus on mobile computing and the wireless Web as a way to conduct commerce-oriented transactions. M-commerce Websites that are usability friendly must emphasize information quality, system quality, and service quality, as these are proxy measures to mobile commerce user…

  4. High-Resolution Gas Metering and Nonintrusive Appliance Load Monitoring System

    NASA Astrophysics Data System (ADS)

    Tewolde, Mahder

    This thesis deals with design and implementation of a high-resolution metering system for residential natural gas meters. Detailed experimental measurements are performed on the meter to characterize and understand its measurement properties. Results from these experiments are used to develop a simple, fast and accurate technique to non-intrusively monitor the gas consumption of individual appliances in homes by resolving small amounts of gas usage. The technique is applied on an existing meter retrofitted with a module that includes a high-resolution encoder to collect gas flow data and a microprocessor to analyze and identify appliance load profiles. This approach provides a number of appealing features including low cost, easy installation and integration with automated meter reading (AMR) systems. The application of this method to residential gas meters currently deployed is also given. This is done by performing a load simulation on realistic gas loads with the aim of identifying the necessary parameters that minimize the cost and complexity of the mechanical encoder module. The primary benefits of the system are efficiency analysis, appliance health monitoring and real-time customer feedback of gas usage. Additional benefits of include the ability to detect very small leaks and theft. This system has the potential for wide scale market adoption.

  5. 40 CFR 86.884-9 - Smoke measurement system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... extinction meter. ER06OC93.182 (b) Equipment. The following equipment shall be used in the system. (1... used to remove the exhaust from the test site. (2) Smokemeter (light extinction meter)—continuous... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  6. 40 CFR 86.884-9 - Smoke measurement system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... extinction meter. ER06OC93.182 (b) Equipment. The following equipment shall be used in the system. (1... used to remove the exhaust from the test site. (2) Smokemeter (light extinction meter)—continuous... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  7. 40 CFR 86.884-9 - Smoke measurement system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... extinction meter. ER06OC93.182 (b) Equipment. The following equipment shall be used in the system. (1... used to remove the exhaust from the test site. (2) Smokemeter (light extinction meter)—continuous... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  8. 40 CFR 86.884-9 - Smoke measurement system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... extinction meter. ER06OC93.182 (b) Equipment. The following equipment shall be used in the system. (1... used to remove the exhaust from the test site. (2) Smokemeter (light extinction meter)—continuous... a remote control unit. (ix) Light extinction meters employing substantially identical measurement...

  9. Record completeness and data concordance in an anesthesia information management system using context-sensitive mandatory data-entry fields.

    PubMed

    Avidan, Alexander; Weissman, Charles

    2012-03-01

    Use of an anesthesia information management system (AIMS) does not insure record completeness and data accuracy. Mandatory data-entry fields can be used to assure data completeness. However, they are not suited for data that is mandatory depending on the clinical situation (context sensitive). For example, information on equal breath sounds should be mandatory with tracheal intubation, but not with mask ventilation. It was hypothesized that employing context-sensitive mandatory data-entry fields can insure high data-completeness and accuracy while maintaining usability. A commercial off-the-shelf AIMS was enhanced using its built-in VBScript programming tool to build event-driven forms with context-sensitive mandatory data-entry fields. One year after introduction of the system, all anesthesia records were reviewed for data completeness. Data concordance, used as a proxy for accuracy, was evaluated using verifiable age-related data. Additionally, an anonymous satisfaction survey on general acceptance and usability of the AIMS was performed. During the initial 12 months of AIMS use, 12,241 (99.6%) of 12,290 anesthesia records had complete data. Concordances of entered data (weight, size of tracheal tubes, laryngoscopy blades and intravenous catheters) with patients' ages were 98.7-99.9%. The AIMS implementation was deemed successful by 98% of the anesthesiologists. Users rated the AIMS usability in general as very good and the data-entry forms in particular as comfortable. Due to the complexity and the high costs of implementation of an anesthesia information management system it was not possible to compare various system designs (for example with or without context-sensitive mandatory data entry-fields). Therefore, it is possible that a different or simpler design would have yielded the same or even better results. This refers also to the evaluation of usability, since users did not have the opportunity to work with different design approaches or even different computer programs. Using context-sensitive mandatory fields in an anesthesia information management system was associated with high record completeness rate and data concordance. In addition, the system's usability was rated as very good by its users. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Traceable calibration of ultraviolet meters used with broadband, extended sources.

    PubMed

    Coleman, A J; Collins, M; Saunders, J E

    2000-01-01

    A calibration system has been developed to provide increased accuracy in the measurement of the irradiance responsivity appropriate for UV meters used with broadband, extended sources of the type employed in phototherapy. The single wavelength responsivity of the test meter is obtained in the wavelength range 250-400 nm by intercomparison with a transfer standard meter in a narrow, monochromatic beam. Traceability to primary standard irradiance scales is provided via the National Measurement System with a best uncertainty of 7% (at 95% confidence). The effective responsivity of the test meter, when used with broadband extended sources, is calculated using the measured spectral and angular response of the meter and tabulated data on the spectral and spatial characteristics of the source radiance. The uncertainty in the effective responsivity, independent of the source variability, is estimated to be 10% (at 95% confidence). The advantages of this calibration system over existing approaches are discussed.

  11. Does user-centred design affect the efficiency, usability and safety of CPOE order sets?

    PubMed

    Chan, Julie; Shojania, Kaveh G; Easty, Anthony C; Etchells, Edward E

    2011-05-01

    Application of user-centred design principles to Computerized provider order entry (CPOE) systems may improve task efficiency, usability or safety, but there is limited evaluative research of its impact on CPOE systems. We evaluated the task efficiency, usability, and safety of three order set formats: our hospital's planned CPOE order sets (CPOE Test), computer order sets based on user-centred design principles (User Centred Design), and existing pre-printed paper order sets (Paper). 27 staff physicians, residents and medical students. Sunnybrook Health Sciences Centre, an academic hospital in Toronto, Canada. Methods Participants completed four simulated order set tasks with three order set formats (two CPOE Test tasks, one User Centred Design, and one Paper). Order of presentation of order set formats and tasks was randomized. Users received individual training for the CPOE Test format only. Completion time (efficiency), requests for assistance (usability), and errors in the submitted orders (safety). 27 study participants completed 108 order sets. Mean task times were: User Centred Design format 273 s, Paper format 293 s (p=0.73 compared to UCD format), and CPOE Test format 637 s (p<0.0001 compared to UCD format). Users requested assistance in 31% of the CPOE Test format tasks, whereas no assistance was needed for the other formats (p<0.01). There were no significant differences in number of errors between formats. The User Centred Design format was more efficient and usable than the CPOE Test format even though training was provided for the latter. We conclude that application of user-centred design principles can enhance task efficiency and usability, increasing the likelihood of successful implementation.

  12. Does user-centred design affect the efficiency, usability and safety of CPOE order sets?

    PubMed Central

    Chan, Julie; Shojania, Kaveh G; Easty, Anthony C

    2011-01-01

    Background Application of user-centred design principles to Computerized provider order entry (CPOE) systems may improve task efficiency, usability or safety, but there is limited evaluative research of its impact on CPOE systems. Objective We evaluated the task efficiency, usability, and safety of three order set formats: our hospital's planned CPOE order sets (CPOE Test), computer order sets based on user-centred design principles (User Centred Design), and existing pre-printed paper order sets (Paper). Participants 27staff physicians, residents and medical students. Setting Sunnybrook Health Sciences Centre, an academic hospital in Toronto, Canada. Methods Participants completed four simulated order set tasks with three order set formats (two CPOE Test tasks, one User Centred Design, and one Paper). Order of presentation of order set formats and tasks was randomized. Users received individual training for the CPOE Test format only. Main Measures Completion time (efficiency), requests for assistance (usability), and errors in the submitted orders (safety). Results 27 study participants completed 108 order sets. Mean task times were: User Centred Design format 273 s, Paper format 293 s (p=0.73 compared to UCD format), and CPOE Test format 637 s (p<0.0001 compared to UCD format). Users requested assistance in 31% of the CPOE Test format tasks, whereas no assistance was needed for the other formats (p<0.01). There were no significant differences in number of errors between formats. Conclusions The User Centred Design format was more efficient and usable than the CPOE Test format even though training was provided for the latter. We conclude that application of user-centred design principles can enhance task efficiency and usability, increasing the likelihood of successful implementation. PMID:21486886

  13. Iterative User Interface Design for Automated Sequential Organ Failure Assessment Score Calculator in Sepsis Detection

    PubMed Central

    Herasevich, Vitaly

    2017-01-01

    Background The new sepsis definition has increased the need for frequent sequential organ failure assessment (SOFA) score recalculation and the clerical burden of information retrieval makes this score ideal for automated calculation. Objective The aim of this study was to (1) estimate the clerical workload of manual SOFA score calculation through a time-motion analysis and (2) describe a user-centered design process for an electronic medical record (EMR) integrated, automated SOFA score calculator with subsequent usability evaluation study. Methods First, we performed a time-motion analysis by recording time-to-task-completion for the manual calculation of 35 baseline and 35 current SOFA scores by 14 internal medicine residents over a 2-month period. Next, we used an agile development process to create a user interface for a previously developed automated SOFA score calculator. The final user interface usability was evaluated by clinician end users with the Computer Systems Usability Questionnaire. Results The overall mean (standard deviation, SD) time-to-complete manual SOFA score calculation time was 61.6 s (33). Among the 24% (12/50) usability survey respondents, our user-centered user interface design process resulted in >75% favorability of survey items in the domains of system usability, information quality, and interface quality. Conclusions Early stakeholder engagement in our agile design process resulted in a user interface for an automated SOFA score calculator that reduced clinician workload and met clinicians’ needs at the point of care. Emerging interoperable platforms may facilitate dissemination of similarly useful clinical score calculators and decision support algorithms as “apps.” A user-centered design process and usability evaluation should be considered during creation of these tools. PMID:28526675

  14. Iterative User Interface Design for Automated Sequential Organ Failure Assessment Score Calculator in Sepsis Detection.

    PubMed

    Aakre, Christopher Ansel; Kitson, Jaben E; Li, Man; Herasevich, Vitaly

    2017-05-18

    The new sepsis definition has increased the need for frequent sequential organ failure assessment (SOFA) score recalculation and the clerical burden of information retrieval makes this score ideal for automated calculation. The aim of this study was to (1) estimate the clerical workload of manual SOFA score calculation through a time-motion analysis and (2) describe a user-centered design process for an electronic medical record (EMR) integrated, automated SOFA score calculator with subsequent usability evaluation study. First, we performed a time-motion analysis by recording time-to-task-completion for the manual calculation of 35 baseline and 35 current SOFA scores by 14 internal medicine residents over a 2-month period. Next, we used an agile development process to create a user interface for a previously developed automated SOFA score calculator. The final user interface usability was evaluated by clinician end users with the Computer Systems Usability Questionnaire. The overall mean (standard deviation, SD) time-to-complete manual SOFA score calculation time was 61.6 s (33). Among the 24% (12/50) usability survey respondents, our user-centered user interface design process resulted in >75% favorability of survey items in the domains of system usability, information quality, and interface quality. Early stakeholder engagement in our agile design process resulted in a user interface for an automated SOFA score calculator that reduced clinician workload and met clinicians' needs at the point of care. Emerging interoperable platforms may facilitate dissemination of similarly useful clinical score calculators and decision support algorithms as "apps." A user-centered design process and usability evaluation should be considered during creation of these tools. ©Christopher Ansel Aakre, Jaben E Kitson, Man Li, Vitaly Herasevich. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 18.05.2017.

  15. A Mobile App (BEDSide Mobility) to Support Nurses' Tasks at the Patient's Bedside: Usability Study.

    PubMed

    Ehrler, Frederic; Weinhold, Thomas; Joe, Jonathan; Lovis, Christian; Blondon, Katherine

    2018-03-21

    The introduction of clinical information systems has increased the amount of clinical documentation. Although this documentation generally improves patient safety, it has become a time-consuming task for nurses, which limits their time with the patient. On the basis of a user-centered methodology, we have developed a mobile app named BEDSide Mobility to support nurses in their daily workflow and to facilitate documentation at the bedside. The aim of the study was to assess the usability of the BEDSide Mobility app in terms of the navigation and interaction design through usability testing. Nurses were asked to complete a scenario reflecting their daily work with patients. Their interactions with the app were captured with eye-tracking glasses and by using the think aloud protocol. After completing the tasks, participants filled out the system usability scale questionnaire. Descriptive statistics were used to summarize task completion rates and the users' performance. A total of 10 nurses (aged 21-50) participated in the study. Overall, they were satisfied with the navigation, layout, and interaction design of the app, with the exception of one user who was unfamiliar with smartphones. The problems identified were related to the ambiguity of some icons, the navigation logic, and design inconsistency. Besides the usability issues identified in the app, the participants' results do indicate good usability, high acceptance, and high satisfaction with the developed app. However, the results must be taken with caution because of the poor ecological validity of the experimental setting. ©Frederic Ehrler, Thomas Weinhold, Jonathan Joe, Christian Lovis, Katherine Blondon. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 21.03.2018.

  16. High usability of a smartphone application for reporting symptoms in adults with cystic fibrosis.

    PubMed

    Wood, Jamie; Jenkins, Sue; Putrino, David; Mulrennan, Siobhain; Morey, Sue; Cecins, Nola; Hill, Kylie

    2017-01-01

    Introduction In cystic fibrosis, exacerbations impair lung function and health-related quality of life, increase healthcare costs and reduce survival. Delayed reporting of worsening symptoms can result in more severe exacerbations and worse clinical outcomes; therefore there is a need for a novel approach to facilitate the early identification and treatment of exacerbations in this population. This study investigated the usability of a smartphone application to report symptoms in adults with cystic fibrosis, and the observer agreement in clinical decision-making between senior clinicians interpreting smartphone application responses. Methods Adults with cystic fibrosis used the smartphone application weekly for four weeks. The application comprised 10 yes/no questions regarding respiratory symptoms and two regarding emotional well-being. Usability was measured with the System Usability Scale; Observer agreement was tested by providing a cystic fibrosis physician and a nurse practitioner with 45 clinical scenarios. For each scenario the clinicians, who were blinded to each other's responses, were asked to indicate whether or not they would: (i) initiate telephone contact, and/or (ii) request a clinic visit for the individual. Results Ten participants (five female), aged mean (SD) 33 (11) years, FEV1 49 (27)% predicted completed the study. The mean (SD) System Usability Scale score was 94 (6). There was perfect agreement between clinicians for initiating contact with the participant ( κ = 1.0, p < 0.001), and near-perfect for requesting a clinic visit ( κ = 0.86, p < 0.001). Discussion The use of a smartphone application for reporting symptoms in adults with cystic fibrosis has excellent usability and near-perfect agreement between senior clinicians when interpreting the application responses.

  17. Adapting a commercial power system simulator for smart grid based system study and vulnerability assessment

    NASA Astrophysics Data System (ADS)

    Navaratne, Uditha Sudheera

    The smart grid is the future of the power grid. Smart meters and the associated network play a major role in the distributed system of the smart grid. Advance Metering Infrastructure (AMI) can enhance the reliability of the grid, generate efficient energy management opportunities and many innovations around the future smart grid. These innovations involve intense research not only on the AMI network itself but as also on the influence an AMI network can have upon the rest of the power grid. This research describes a smart meter testbed with hardware in loop that can facilitate future research in an AMI network. The smart meters in the testbed were developed such that their functionality can be customized to simulate any given scenario such as integrating new hardware components into a smart meter or developing new encryption algorithms in firmware. These smart meters were integrated into the power system simulator to simulate the power flow variation in the power grid on different AMI activities. Each smart meter in the network also provides a communication interface to the home area network. This research delivers a testbed for emulating the AMI activities and monitoring their effect on the smart grid.

  18. A compact perspiration meter system with capacitive humidity sensor for wearable health-care applications

    NASA Astrophysics Data System (ADS)

    Mitani, Yusuke; Miyaji, Kousuke; Kaneko, Satoshi; Uekura, Takaharu; Momose, Hideya; Johguchi, Koh

    2018-04-01

    This paper presents a compact wearable perspiration meter system using a 180-nm CMOS technology. With custom chip and board design, the proposed perspiration meter, which can measure a qualitative sweating rate, is integrated into 15 × 20 mm2. From the experimental results, the capacitances of the humidity sensors with analog-to-digital converter and band-gap reference circuits can operate accurately without hysteresis. In addition, a demonstration with simulated human skin is carried out to investigate the sensor’s performance under real environments. The proposed perspiration meter can output values equivalent to a conventional meter. As a result, it is verified that the proposed system can be used as a human sweat sensor for wearable application.

  19. Human Factors for Nursing: From In-Situ Testing to Mobile Usability Engineering.

    PubMed

    Kushniruk, Andre W; Borycki, Elizabeth M; Solvoll, Terje; Hullin, Carola

    2016-01-01

    The tutorial goal is to familiarize participants with human aspects of health informatics and human-centered approaches to the design, evaluation and deployment of both usable and safe healthcare information systems. The focus will be on demonstrating and teaching practical and low-cost methods for evaluating mobile applications in nursing. Basic background to testing methods will be provided, followed by live demonstration of the methods. Then the audience will break into small groups to explore the application of the methods to applications of interest (there will be a number of possible applications that will be available for applications in areas such as electronic health records and decision support, however, if the groups have applications of specific interest to them that will be possible). The challenges of conducting usability testing, and in particular mobile usability testing will be discussed along with practical solutions. The target audience includes practicing nurses and nurse researchers, nursing informatics specialists, nursing students, nursing managers and health informatics professionals interested in improving the usability and safety of healthcare applications.

  20. Usability of a home-based test for the measurement of fecal calprotectin in asymptomatic IBD patients.

    PubMed

    Bello, Caroline; Roseth, Arne; Guardiola, Jordi; Reenaers, Catherine; Ruiz-Cerulla, Alexandra; Van Kemseke, Catherine; Arajol, Claudia; Reinhard, Christian; Seidel, Laurence; Louis, Edouard

    2017-09-01

    The aim of our work was to test the usability of fecal calprotectin (FC) home-based test in inflammatory bowel disease (IBD) patients. IBD patients were prospectively recruited. They had to measure FC with a dedicated tool and smartphone application, 5 times at two weeks intervals over an 8 weeks period. They had to fill in a usability questionnaire at the first and the last FC measurement. A System Usability Scale (SUS: 0-100) and the Global Score of Usability (GSU: 0-85) were calculated. FC was also centrally measured by ELISA. Fifty-eight patients were recruited. Forty-two performed at least one FC measurement and 27 performed all the FC requested measurements. The median (IQR) SUS (0-100) at the first and last use were 85 (78-90) and 81 (70-88), respectively; the median (IQR) GSU (0-85) at the first and last use were 74 (69-80) and 77 (68-83), respectively. Adherence to the planned measurements and usability of the tool were higher in females and in less severe disease. The intra-class correlation coefficient between home-based and centrally measured FC was 0.88. The adherence to home-based measurement of FC was fair. Usability scores for the home-based test were high. There was a good correlation with the centrally measured FC by ELISA. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  1. Applying User-Centered Design Methods to the Development of an mHealth Application for Use in the Hospital Setting by Patients and Care Partners.

    PubMed

    Couture, Brittany; Lilley, Elizabeth; Chang, Frank; DeBord Smith, Ann; Cleveland, Jessica; Ergai, Awatef; Katsulis, Zachary; Benneyan, James; Gershanik, Esteban; Bates, David W; Collins, Sarah A

    2018-04-01

     Developing an optimized and user-friendly mHealth application for patients and family members in the hospital environment presents unique challenges given the diverse patient population and patients' various states of well-being.  This article describes user-centered design methods and results for developing the patient and family facing user interface and functionality of MySafeCare, a safety reporting tool for hospitalized patients and their family members.  Individual and group usability sessions were conducted with specific testing scenarios for participants to follow to test the usability and functionality of the tool. Participants included patients, family members, and Patient and Family Advisory Council (PFAC) members. Engagement rounds were also conducted on study units and lessons learned provided additional information to the usability work. Usability results were aligned with Nielsen's Usability Heuristics.  Eleven patients and family members and 25 PFAC members participated in usability testing and over 250 patients and family members were engaged during research team rounding. Specific themes resulting from the usability testing sessions influenced the changes made to the user interface design, workflow functionality, and terminology.  User-centered design should focus on workflow functionality, terminology, and user interface issues for mHealth applications. These themes illustrated issues aligned with four of Nielsen's Usability Heuristics: match between system and the real world, consistency and standards, flexibility and efficiency of use, and aesthetic and minimalist design. We identified workflow and terminology issues that may be specific to the use of an mHealth application focused on safety and used by hospitalized patients and their families. Schattauer GmbH Stuttgart.

  2. Bathymetric terrain model of the Atlantic margin for marine geological investigations

    USGS Publications Warehouse

    Andrews, Brian D.; Chaytor, Jason D.; ten Brink, Uri S.; Brothers, Daniel S.; Gardner, James V.; Lobecker, Elizabeth A.; Calder, Brian R.

    2016-01-01

    A bathymetric terrain model of the Atlantic margin covering almost 725,000 square kilometers of seafloor from the New England Seamounts in the north to the Blake Basin in the south is compiled from existing multibeam bathymetric data for marine geological investigations. Although other terrain models of the same area are extant, they are produced from either satellite-derived bathymetry at coarse resolution (ETOPO1), or use older bathymetric data collected by using a combination of single beam and multibeam sonars (Coastal Relief Model). The new multibeam data used to produce this terrain model have been edited by using hydrographic data processing software to maximize the quality, usability, and cartographic presentation of the combined 100-meter resolution grid. The final grid provides the largest high-resolution, seamless terrain model of the Atlantic margin..

  3. Characterizing Giant Exoplanets through Multiwavelength Transit Observations: HAT-P-5 b

    NASA Astrophysics Data System (ADS)

    PeQueen, David Jeffrey; Cole, Jackson Lane; Gardner, Cristilyn N.; Garver, Bethany Ray; Jarka, Kyla L.; Kar, Aman; McGough, Aylin M.; Rivera, Daniel Ivan; Kasper, David; Jang-Condell, Hannah; Kobulnicky, Henry; Dale, Daniel

    2018-01-01

    During the summer of 2017, we observed hot Jupiter-type exoplanet transit events using the Wyoming Infrared Observatory’s 2.3 meter telescope. We observed 14 unique exoplanets during transit events; one such target was HAT-P-5 b. In total, we collected 53 usable science images in the Sloan filter set, particularly with the g’, r’, z’, and i’ band wavelength filters. This exoplanet transited approximately 40 minutes earlier than the currently published literature suggests. After reducing the data and running a Markov chain Monte Carlo analysis, we present results describing the planetary radius, semi-major axis, orbital period, and inclination of HAT-P-5 b. Characteristics of Rayleigh scattering are present in the atmosphere of this exoplanet. This work is supported by the National Science Foundation under REU grant AST 1560461.

  4. RECENT DEVELOPMENTS IN HYDROLOGIC INSTRUMENTATION.

    USGS Publications Warehouse

    Latkovich, Vito J.

    1985-01-01

    The availability of space-age materials and implementation of state-of-the-art electronics is making possible the recent developments of hydrologic instrumentation. Material developments include: Synthetic-fiber sounding and tag lines; fiberglass wading rod; polymer (plastic) sheaves, pulleys and sampler components; and polymer (plastic) bucket wheels for current meters. These materials are very cost effective and efficient. Electromechanical and electronic developments and applications include: adaptable data acquisition system; downhole sampler for hazardous substances; current-meter digitizer; hydraulic power/drive system for discharge measurements and water-quality sampling; non-contact water-level sensors; minimum data recorder; acoustic velocity meters, and automated current meter discharge-measurement system.

  5. Development of a Prototype Continuity of Care Record with Context-Specific Links to Meet the Information Needs of Case Managers for Persons Living with HIV

    PubMed Central

    Cimino, James J.; Bakken, Suzanne

    2012-01-01

    Objectives (1) To develop a prototype Continuity of Care Record (CCR) with context-specific links to electronic HIV information resources; and (2) to assess case managers’ perceptions regarding the usability of the prototype. Methods We integrated context-specific links to HIV case management information resources into a prototype CCR using the Infobutton Manager and Librarian Infobutton Tailoring Environment (LITE). Case managers (N=9) completed a think-aloud protocol and the Computer System Usability Questionnaire (CSUQ) to evaluate the usability of the prototype. Verbalizations from the think-aloud protocol were summarized using thematic analysis. CSUQ data were analyzed with descriptive statistics. Results Although participants expressed positive comments regarding the usability of the prototype, the think-aloud protocol also identified the need for improvement in resource labels and for additional resources. On a scale ranging from 1 (strongly agree) to 7 (strongly disagree), the average CSUQ overall satisfaction was 2.25 indicating that users (n=9) were generally satisfied with the system. Mean CSUQ factor scores were: System Usefulness (M=2.13), Information Quality (M=2.46), and Interface Quality (M=2.26). Conclusion Our novel application of the Infobutton Manager and LITE in the context of case management for persons living with HIV in community-based settings resulted in a prototype CCR with infobuttons that met the majority of case managers’ information needs and received relatively positive usability ratings. Findings from this study inform future integration of context-specific links into CCRs and electronic health records and support their use for meeting end-users information needs. PMID:22632821

  6. Comparing two anesthesia information management system user interfaces: a usability evaluation.

    PubMed

    Wanderer, Jonathan P; Rao, Anoop V; Rothwell, Sarah H; Ehrenfeld, Jesse M

    2012-11-01

    Anesthesia information management systems (AIMS) have been developed by multiple vendors and are deployed in thousands of operating rooms around the world, yet not much is known about measuring and improving AIMS usability. We developed a methodology for evaluating AIMS usability in a low-fidelity simulated clinical environment and used it to compare an existing user interface with a revised version. We hypothesized that the revised user interface would be more useable. In a low-fidelity simulated clinical environment, twenty anesthesia providers documented essential anesthetic information for the start of the case using both an existing and a revised user interface. Participants had not used the revised user interface previously and completed a brief training exercise prior to the study task. All participants completed a workload assessment and a satisfaction survey. All sessions were recorded. Multiple usability metrics were measured. The primary outcome was documentation accuracy. Secondary outcomes were perceived workload, number of documentation steps, number of user interactions, and documentation time. The interfaces were compared and design problems were identified by analyzing recorded sessions and survey results. Use of the revised user interface was shown to improve documentation accuracy from 85.1% to 92.4%, a difference of 7.3% (95% confidence interval [CI] for the difference 1.8 to 12.7). The revised user interface decreased the number of user interactions by 6.5 for intravenous documentation (95% CI 2.9 to 10.1) and by 16.1 for airway documentation (95% CI 11.1 to 21.1). The revised user interface required 3.8 fewer documentation steps (95% CI 2.3 to 5.4). Airway documentation time was reduced by 30.5 seconds with the revised workflow (95% CI 8.5 to 52.4). There were no significant time differences noted in intravenous documentation or in total task time. No difference in perceived workload was found between the user interfaces. Two user interface design problems were identified in the revised user interface. The usability of anesthesia information management systems can be evaluated using a low-fidelity simulated clinical environment. User testing of the revised user interface showed improvement in some usability metrics and highlighted areas for further revision. Vendors of AIMS and those who use them should consider adopting methods to evaluate and improve AIMS usability.

  7. Participatory interaction design in user requirements specification in healthcare.

    PubMed

    Martikainen, Susanna; Ikävalko, Pauliina; Korpela, Mikko

    2010-01-01

    Healthcare information systems are accused of poor usability even in the popular media in Finland. Doctors especially have been very critical and actively expressed their opinions in public. User involvement and user-centered design methods are seen as the key solution to usability problems. In this paper we describe a research case where participatory methods were experimented within healthcare information systems development in medicinal care in a hospital. The study was part of a larger research project on Activity-driven Information Systems Development in healthcare. The study started by finding out about and modeling the present state of medicinal care in the hospital. After that it was important to define and model the goal state. The goal state, facilitated by the would-be software package, was modeled with the help of user interface drawings as one way of prototyping. Traditional usability methods were extended during the study. According to the health professionals' feedback, the use of participatory and user-centered interaction design methods, particularly user interface drawings enabled them to describe their requirements and create common understanding with the system developers.

  8. Improving the Interoperability and Usability of NASA Earth Observation Data

    NASA Astrophysics Data System (ADS)

    Walter, J.; Berrick, S. W.; Murphy, K. J.; Mitchell, A. E.; Tilmes, C.

    2014-12-01

    NASA's Earth Science Data and Information System Project (ESDIS) is charged with managing, maintaining, and evolving NASA's Earth Observing System Data and Information System (EOSDIS) and is responsible for processing, archiving, and distributing NASA Earth Science data. The system supports a multitude of missions and serves diverse science research and other user communities. While NASA has made, and continues to make, great strides in the discoverability and accessibility of its earth observation data holdings, issues associated with data interoperability and usability still present significant challenges to realizing the full scientific and societal benefits of these data. This concern has been articulated by multiple government agencies, both U.S. and international, as well as other non-governmental organizations around the world. Among these is the White House Office of Science and Technology Policy who, in response, has launched the Big Earth Data Initiative and the Climate Data Initiative to address these concerns for U.S. government agencies. This presentation will describe NASA's approach for addressing data interoperability and usability issues with our earth observation data.

  9. Using scenarios and personas to enhance the effectiveness of heuristic usability evaluations for older adults and their care team.

    PubMed

    Kneale, Laura; Mikles, Sean; Choi, Yong K; Thompson, Hilaire; Demiris, George

    2017-09-01

    Using heuristics to evaluate user experience is a common methodology for human-computer interaction studies. One challenge of this method is the inability to tailor results towards specific end-user needs. This manuscript reports on a method that uses validated scenarios and personas of older adults and care team members to enhance heuristics evaluations of the usability of commercially available personal health records for homebound older adults. Our work extends the Chisnell and Redish heuristic evaluation methodology by using a protocol that relies on multiple expert reviews of each system. It further standardizes the heuristic evaluation process through the incorporation of task-based scenarios. We were able to use the modified version of the Chisnell and Redish heuristic evaluation methodology to identify potential usability challenges of two commercially available personal health record systems. This allowed us to: (1) identify potential usability challenges for specific types of users, (2) describe improvements that would be valuable to all end-users of the system, and (3) better understand how the interactions of different users may vary within a single personal health record. The methodology described in this paper may help designers of consumer health information technology tools, such as personal health records, understand the needs of diverse end-user populations. Such methods may be particularly helpful when designing systems for populations that are difficult to recruit for end-user evaluations through traditional methods. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient's and Physical Therapist's Perspective.

    PubMed

    van Lieshout, Remko; Pisters, Martijn F; Vanwanseele, Benedicte; de Bie, Rob A; Wouters, Eveline J; Stukstette, Mirelle J

    2016-01-01

    Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient's compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices that provide real-time feedback. For a successful implementation, usability of the devices is a critical aspect and should be tested from a user's perspective. To describe the usability from the physical therapists' and a patients' perspective of Smartstep and OpenGo-Science to provide feedback on partial weight bearing during supervised rehabilitation of patients after lower-limb trauma or surgery. In a convergent mixed-methods design, qualitative and quantitative data were collected. Usability was subdivided into user performance, satisfaction and acceptability. Patients prescribed with partial weight bearing and their physical therapists were asked to use SmartStep and OpenGo-Science during supervised rehabilitation. Usability was qualitatively tested by a think-aloud method and a semi-structured interview and quantitatively tested by the System-Usability-Scale (SUS) and closed questions. For the qualitative data thematic content analyses were used. Nine pairs of physical therapists and their patients participated. The mean SUS scores for patients and physical therapists were for SmartStep 70 and 53, and for OpenGo-Science 79 and 81, respectively. Scores were interpreted with the Curved Grading Scale. The qualitative data showed that there were mixed views and perceptions from patients and physical therapists on satisfaction and acceptability. This study gives insight in the usability of two biofeedback devices from the patient's and physical therapist's perspective. The overall usability from both perspectives seemed to be acceptable for OpenGo-Science. For SmartStep, overall usability seemed only acceptable from the patient's perspective. The study findings could help clinicians to decide which biofeedback device is appropriate for their given situation and provide information for future development of biofeedback devices.

  11. ELECTRICAL LOAD ANTICIPATOR AND RECORDER

    DOEpatents

    Werme, J.E.

    1961-09-01

    A system is described in which an indication of the prevailing energy consumption in an electrical power metering system and a projected power demand for one demand in terval is provided at selected increments of time within the demand interval. Each watt-hour meter in the system is provided with an impulse generator that generates two impulses for each revolution of the meter disc. In each demand interval, for example, one half-hour, of the metering system, the total impulses received from all of the meters are continuously totaled for each 5-minute interval and multiplied by a number from 6 to 1 depending upon which 5- minute interval the impulses were received. This value is added to the total pulses received in the intervals preceding the current 5-minute interval within the half-hour demand interval tc thereby provide an indication of the projected power demand every 5 minutes in the demand interval.

  12. Clinical pathways for primary care: current use, interest and perceived usability.

    PubMed

    Waters, Richard C; Toy, Jennifer M; Drechsler, Adam

    2018-02-26

    Translating clinical evidence to daily practice remains a challenge and may improve with clinical pathways. We assessed interest in and usability of clinical pathways by primary care professionals. An online survey was created. Interest in pathways for patient care and learning was assessed at start and finish. Participants completed baseline questions then pathway-associated question sets related to management of 2 chronic diseases. Perceived pathway usability was assessed using the system usability scale. Accuracy and confidence of answers was compared for baseline and pathway-assisted questions. Of 115 participants, 17.4% had used clinical pathways, the lowest of decision support tool types surveyed. Accuracy and confidence in answers significantly improved for all pathways. Interest in using pathways daily or weekly was above 75% for the respondents. There is low utilization of, but high interest in, clinical pathways by primary care clinicians. Pathways improve accuracy and confidence in answering written clinical questions.

  13. Older Adults' Acceptance of Activity Trackers

    PubMed Central

    Preusse, Kimberly C.; Mitzner, Tracy L.; Fausset, Cara Bailey; Rogers, Wendy A.

    2016-01-01

    Objective To assess the usability and acceptance of activity tracking technologies by older adults. Method First in our multi-method approach, we conducted heuristic evaluations of two activity trackers that revealed potential usability barriers to acceptance. Next, questionnaires and interviews were administered to 16 older adults (Mage=70, SDage=3.09, rangeage= 65-75) before and after a 28-day field study to understand facilitators and additional barriers to acceptance. These measurements were supplemented with diary and usage data and assessed if and why users overcame usability issues. Results The heuristic evaluation revealed usability barriers in System Status Visibility; Error Prevention; and Consistency and Standards. The field study revealed additional barriers (e.g., accuracy, format), and acceptance-facilitators (e.g., goal-tracking, usefulness, encouragement). Discussion The acceptance of wellness management technologies, such as activity trackers, may be increased by addressing acceptance-barriers during deployment (e.g., providing tutorials on features that were challenging, communicating usefulness). PMID:26753803

  14. The E-health Literacy Demands of Australia's My Health Record: A Heuristic Evaluation of Usability.

    PubMed

    Walsh, Louisa; Hemsley, Bronwyn; Allan, Meredith; Adams, Natalie; Balandin, Susan; Georgiou, Andrew; Higgins, Isabel; McCarthy, Shaun; Hill, Sophie

    2017-01-01

    My Health Record is Australia's electronic personal health record system, which was introduced in July 2012. As of August 2017, approximately 21 percent of Australia's total population was registered to use My Health Record. Internationally, usability issues have been shown to negatively influence the uptake and use of electronic health record systems, and this scenario may particularly affect people who have low e-health literacy. It is likely that usability issues are negatively affecting the uptake and use of My Health Record in Australia. To identify potential e-health literacy-related usability issues within My Health Record through a heuristic evaluation method. Between September 14 and October 12, 2016, three of the authors conducted a heuristic evaluation of the two consumer-facing components of My Health Record-the information website and the electronic health record itself. These two components were evaluated against two sets of heuristics-the Health Literacy Online checklist and the Monkman Heuristics. The Health Literacy Online checklist and Monkman Heuristics are evidence-based checklists of web design elements with a focus on design for audiences with low health literacy. During this heuristic evaluation, the investigators individually navigated through the consumer-facing components of My Health Record, recording instances where the My Health Record did not conform to the checklist criteria. After the individual evaluations were completed, the investigators conferred and aggregated their results. From this process, a list of usability violations was constructed. When evaluated against the Health Literacy Online Checklist, the information website demonstrated violations in 12 of 35 criteria, and the electronic health record demonstrated violations in 16 of 35 criteria. When evaluated against the Monkman Heuristics, the information website demonstrated violations in 7 of 11 criteria, and the electronic health record demonstrated violations in 9 of 11 criteria. The identified violations included usability issues with the reading levels used within My Health Record, the graphic design elements, the layout of web pages, and a lack of images and audiovisual tools to support learning. Other important usability issues included a lack of translated resources, difficulty using accessibility tools, and complexity of the registration processes. My Health Record is an important piece of technology that has the potential to facilitate better communication between consumers and their health providers. However, this heuristic evaluation demonstrated that many usability-related elements of My Health Record cater poorly to users at risk of having low e-health literacy. Usability issues have been identified as an important barrier to use of personal health records internationally, and the findings of this heuristic evaluation demonstrate that usability issues may be substantial barriers to the uptake and use of My Health Record.

  15. The E-health Literacy Demands of Australia's My Health Record: A Heuristic Evaluation of Usability

    PubMed Central

    Walsh, Louisa; Hemsley, Bronwyn; Allan, Meredith; Adams, Natalie; Balandin, Susan; Georgiou, Andrew; Higgins, Isabel; McCarthy, Shaun; Hill, Sophie

    2017-01-01

    Background My Health Record is Australia's electronic personal health record system, which was introduced in July 2012. As of August 2017, approximately 21 percent of Australia's total population was registered to use My Health Record. Internationally, usability issues have been shown to negatively influence the uptake and use of electronic health record systems, and this scenario may particularly affect people who have low e-health literacy. It is likely that usability issues are negatively affecting the uptake and use of My Health Record in Australia. Objective To identify potential e-health literacy–related usability issues within My Health Record through a heuristic evaluation method. Methods Between September 14 and October 12, 2016, three of the authors conducted a heuristic evaluation of the two consumer-facing components of My Health Record—the information website and the electronic health record itself. These two components were evaluated against two sets of heuristics—the Health Literacy Online checklist and the Monkman Heuristics. The Health Literacy Online checklist and Monkman Heuristics are evidence-based checklists of web design elements with a focus on design for audiences with low health literacy. During this heuristic evaluation, the investigators individually navigated through the consumer-facing components of My Health Record, recording instances where the My Health Record did not conform to the checklist criteria. After the individual evaluations were completed, the investigators conferred and aggregated their results. From this process, a list of usability violations was constructed. Results When evaluated against the Health Literacy Online Checklist, the information website demonstrated violations in 12 of 35 criteria, and the electronic health record demonstrated violations in 16 of 35 criteria. When evaluated against the Monkman Heuristics, the information website demonstrated violations in 7 of 11 criteria, and the electronic health record demonstrated violations in 9 of 11 criteria. The identified violations included usability issues with the reading levels used within My Health Record, the graphic design elements, the layout of web pages, and a lack of images and audiovisual tools to support learning. Other important usability issues included a lack of translated resources, difficulty using accessibility tools, and complexity of the registration processes. Conclusion My Health Record is an important piece of technology that has the potential to facilitate better communication between consumers and their health providers. However, this heuristic evaluation demonstrated that many usability-related elements of My Health Record cater poorly to users at risk of having low e-health literacy. Usability issues have been identified as an important barrier to use of personal health records internationally, and the findings of this heuristic evaluation demonstrate that usability issues may be substantial barriers to the uptake and use of My Health Record. PMID:29118683

  16. Usability Testing, User-Centered Design, and LibGuides Subject Guides: A Case Study

    ERIC Educational Resources Information Center

    Sonsteby, Alec; DeJonghe, Jennifer

    2013-01-01

    Usability testing has become a routine way for many libraries to ensure that their Web presence is user-friendly and accessible. At the same time, popular subject guide creation systems, such as LibGuides, decentralize Web content creation and put authorship into the hands of librarians who may not be trained in user-centered design principles. At…

  17. INCOMMANDS TDP: Human Factors Evaluation of the Command Decision Support Capability Prototype

    DTIC Science & Technology

    2009-03-01

    CDSC) design with guidelines and principles stipulated in the INCOMMANDS TDP Human Factors Design and Evaluation Guide. 2. Usability and Utility...INCOMMANDS CDSC. The Heuristic Evaluation helps to ensure that the design of system is compliant with HCI best practices. Whereas the Usability and...implemented to confirm compliance with the INCOMMANDS TDP Human Factors Design and Evaluation Guide

  18. Developing an Understanding of the Nature of Accessibility and Usability Problems Blind Students Face in Web-Enhanced Instruction Environments

    ERIC Educational Resources Information Center

    Babu, Rakesh

    2011-01-01

    The central premise of this research is that blind and visually impaired (BVI) people cannot use the Internet effectively due to accessibility and usability problems. Use of the Internet is indispensable in today's education system that relies on Web-enhanced instruction (WEI). Therefore, BVI students cannot participate effectively in WEI. Extant…

  19. CPOE system design aspects and their qualitative effect on usability.

    PubMed

    Khajouei, Reza; Jaspers, Monique W M

    2008-01-01

    Although many studies have discussed the benefits of Computerized Provider Order Entry (CPOE) systems, their configuration can have a great impact on clinicians' adoption of these systems. Poorly designed CPOE systems can lead to usability problems, users' dissatisfaction and may disrupt normal flow of clinical activities. This paper reports on a literature review focused on the identification of CPOE medication systems' design aspects that impact CPOE systems' usability and create opportunities for medication errors. Our review is based on a systematic literature search in PubMed, EMBASE and Ovid MEDLINE for relevant publications from 1986-2006. We categorized the design aspects extracted from relevant publications into six different groups: 1) timing of alerts, 2) log in/out procedures, 3) pick lists and drop down menus, 4) clues and guidelines, 5) documentation and data entry options, and 6) screen display and layout. Our review shows that the manner in which a CPOE system is configured can have a high impact on ease of system use, task behavior of clinicians in ordering drugs, and medication errors. Characterization of consequences associated with certain CPOE design aspects provides insight into how CPOE system designs can be improved to enhance physicians' adoption of these systems and their success. Recommendations are provided to enable CPOE system designers to create CPOE systems that are not only more user friendly and efficient but safer.

  20. Research on Operation Assessment Method for Energy Meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  1. A Method of Evaluating Operation of Electric Energy Meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Li, Tianyang; Cao, Fei; Chu, Pengfei; Zhao, Xinwang; Huang, Rui; Liu, Liping; Zhang, Chenglin

    2018-05-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  2. 47 CFR 15.251 - Operation within the bands 2.9-3.26 GHz, 3.267-3.332 GHz, 3.339-3.3458 GHz, and 3.358-3.6 GHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... exceed 3000 microvolts/meter/MHz at 3 meters in any direction. Further, an AVIS, when in its operating position, shall not produce a field strength greater than 400 microvolts/meter/MHz at 3 meters in any... maximum of 100 microvolts/meter/MHz at 3 meters, measured from 30 MHz to 20 GHz for the complete system...

  3. 20 Meter Solar Sail Analysis and Correlation

    NASA Technical Reports Server (NTRS)

    Taleghani, B. K.; Lively, P. S.; Banik, J.; Murphy, D. M.; Trautt, T. A.

    2005-01-01

    This paper describes finite element analyses and correlation studies to predict deformations and vibration modes/frequencies of a 20-meter solar sail system developed by ATK Space Systems. Under the programmatic leadership of NASA Marshall Space Flight Center's In-Space Propulsion activity, the 20-meter solar sail program objectives were to verify the design, to assess structural responses of the sail system, to implement lessons learned from a previous 10-meter quadrant system analysis and test program, and to mature solar sail technology to a technology readiness level (TRL) of 5. For this 20 meter sail system, static and ground vibration tests were conducted in NASA Glenn Research Center's 100 meter diameter vacuum chamber at Plum Brook station. Prior to testing, a preliminary analysis was performed to evaluate test conditions and to determine sensor and actuator locations. After testing was completed, an analysis of each test configuration was performed. Post-test model refinements included updated properties to account for the mass of sensors, wiring, and other components used for testing. This paper describes the development of finite element models (FEM) for sail membranes and masts in each of four quadrants at both the component and system levels, as well as an optimization procedure for the static test/analyses correlation.

  4. Development and usability testing of FOCUS: a smartphone system for self-management of schizophrenia.

    PubMed

    Ben-Zeev, Dror; Kaiser, Susan M; Brenner, Christopher J; Begale, Mark; Duffecy, Jennifer; Mohr, David C

    2013-12-01

    Mobile Health (mHealth) approaches can support the rehabilitation of individuals with psychiatric conditions. In the current article, we describe the development of a smartphone illness self-management system for people with schizophrenia. The research was conducted with consumers and practitioners at a community-based rehabilitation agency. Stage 1: 904 individuals with schizophrenia or schizoaffective disorder completed a survey reporting on their current use of mobile devices and interest in mHealth services. Eight practitioners completed a survey examining their attitudes and expectations from an mHealth intervention, and identified needs and potential obstacles. Stage 2: A multidisciplinary team incorporated consumer and practitioner input and employed design principles for the development of e-resources for people with schizophrenia to produce an mHealth intervention. Stage 3: 12 consumers participated in laboratory usability sessions. They performed tasks involved in operating the new system, and provided "think aloud" commentary and post-session usability ratings. 570 (63%) of survey respondents reported owning a mobile device and many expressed interest in receiving mHealth services. Most practitioners believed that consumers could learn to use and would benefit from an mHealth intervention. In response, we developed a smartphone system that targets medication adherence, mood regulation, sleep, social functioning, and coping with symptoms. Usability testing revealed several design vulnerabilities, and the system was adapted to address consumer needs and preferences accordingly. Through a comprehensive development process, we produced an mHealth illness self-management intervention that is likely to be used successfully, and is ready for deployment and systemic evaluation in real-world conditions. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  5. An Expert System for Diagnosing Eye Diseases using Forward Chaining Method

    NASA Astrophysics Data System (ADS)

    Munaiseche, C. P. C.; Kaparang, D. R.; Rompas, P. T. D.

    2018-02-01

    Expert System is a system that seeks to adopt human knowledge to the computer, so that the computer can solve problems which are usually done by experts. The purpose of medical expert system is to support the diagnosis process of physicians. It considers facts and symptoms to provide diagnosis. This implies that a medical expert system uses knowledge about diseases and facts about the patients to suggest diagnosis. The aim of this research is to design an expert system application for diagnosing eye diseases using forward chaining method and to figure out user acceptance to this application through usability testing. Eye is selected because it is one of the five senses which is very sensitive and important. The scope of the work is extended to 16 types of eye diseases with 41 symptoms of the disease, arranged in 16 rules. The computer programming language employed was the PHP programming language and MySQL as the Relational Database Management System (RDBMS). The results obtained showed that the expert system was able to successfully diagnose eye diseases corresponding to the selected symptoms entered as query and the system evaluation through usability testing showed the expert system for diagnosis eye diseases had very good rate of usability, which includes learnability, efficiency, memorability, errors, and satisfaction so that the system can be received in the operational environment.

  6. Evaluating Nurses' Satisfaction With Two Nursing Information Systems.

    PubMed

    Khajouei, Reza; Abbasi, Reza

    2017-06-01

    Evaluating user satisfaction is one of the methods to ensure the usability of information systems. Considering the importance of nursing information systems in patient health, the objective of this study is to evaluate nurses' satisfaction with two widely used nursing information systems (Peyvand Dadeh and Tirazhe) in Iran. This descriptive-analytical study was done on 230 nurses in all teaching hospitals of Kerman University of Medical Sciences in 2015. Data were collected using an augmented version of a questionnaire developed by IBM. Data were analyzed by SPSS.16 using descriptive and analytical statistical methods including t test, analysis of variance, and Pearson correlation coefficient. The mean of overall satisfaction with the two systems was 61 ± 2.2 and 74 ± 2.4, respectively. The mean of satisfaction with different systems dimensions, that is, ease of use, information quality, and interface quality, was, respectively, 24 ± 1.9, 26 ± 9.7, and 12 ± 4.7 for Tirazhe and 29 ± 1.1, 39 ± 1.04 and 13 ± 5.3 for Peyvand Dadeh system. Nurses' satisfaction with both systems was at a medium level. The majority of nurses were relatively satisfied with the information quality and user interface quality of these systems. The results suggest that designing nursing information systems in accordance with their users' need improves usability. Hence, policy and decision makers of healthcare institutions should invest on usability when purchasing such systems.

  7. 40 CFR 86.092-2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...), general type of fuel system (i.e., carburetor or fuel injection), catalyst system (e.g., none, oxidization... control systems are emission control components or systems (and fuel metering systems) that have completed... emission control components or systems (and fuel metering systems) that do not qualify as proven emission...

  8. 40 CFR 86.092-2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...), general type of fuel system (i.e., carburetor or fuel injection), catalyst system (e.g., none, oxidization... control systems are emission control components or systems (and fuel metering systems) that have completed... emission control components or systems (and fuel metering systems) that do not qualify as proven emission...

  9. 40 CFR 86.092-2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...), general type of fuel system (i.e., carburetor or fuel injection), catalyst system (e.g., none, oxidization... control systems are emission control components or systems (and fuel metering systems) that have completed... emission control components or systems (and fuel metering systems) that do not qualify as proven emission...

  10. Usability evaluation of in-housed developed ERP system

    NASA Astrophysics Data System (ADS)

    Faisal, Chaudhry Muhammad Nadeem; Shakeel Faridi, Muhammad; Javed, Zahid

    2011-10-01

    Enterprise Resource Planning systems are the combination of different business IS (Information System) applications that are designed according to the organization requirements. Generally ERP systems are suffering from complex user interface issues. Recent research shows that there is a need for improvement concerning, the user interface from their perspectives. In order to design the software applications that are easy to use, memorize and apply to new problems, we must know the users philosophy and something about learning, reminiscence and problems solving. The Usability engineering is the only way to study the deeds of users while interacting with ERP (Enterprise Resource & Planning). This paper will focus on the users' experiences view of financial module in ERP system. The HCI research method, explicitly survey questionnaire method was adopted to gather users understanding in order to evaluate the selected modules for in-housed ERP system. The study involved group of users from two industries, the results can not be generalized as a whole. The study was first time successfully applied Usability evaluation on in-housed ERP in local industry (Masood Textile Mills, Interloop Ltd) in Pakistan. The results may hopefully opened-up an area of research and methodology that could provide considerable further benefits to Industry in developments of Industrial information systems.

  11. Software to Control and Monitor Gas Streams

    NASA Technical Reports Server (NTRS)

    Arkin, C.; Curley, Charles; Gore, Eric; Floyd, David; Lucas, Damion

    2012-01-01

    This software package interfaces with various gas stream devices such as pressure transducers, flow meters, flow controllers, valves, and analyzers such as a mass spectrometer. The software provides excellent user interfacing with various windows that provide time-domain graphs, valve state buttons, priority- colored messages, and warning icons. The user can configure the software to save as much or as little data as needed to a comma-delimited file. The software also includes an intuitive scripting language for automated processing. The configuration allows for the assignment of measured values or calibration so that raw signals can be viewed as usable pressures, flows, or concentrations in real time. The software is based on those used in two safety systems for shuttle processing and one volcanic gas analysis system. Mass analyzers typically have very unique applications and vary from job to job. As such, software available on the market is usually inadequate or targeted on a specific application (such as EPA methods). The goal was to develop powerful software that could be used with prototype systems. The key problem was to generalize the software to be easily and quickly reconfigurable. At Kennedy Space Center (KSC), the prior art consists of two primary methods. The first method was to utilize Lab- VIEW and a commercial data acquisition system. This method required rewriting code for each different application and only provided raw data. To obtain data in engineering units, manual calculations were required. The second method was to utilize one of the embedded computer systems developed for another system. This second method had the benefit of providing data in engineering units, but was limited in the number of control parameters.

  12. Applications of the Renewable Energy Network Optimization Tool

    NASA Astrophysics Data System (ADS)

    Alliss, R.; Link, R.; Apling, D.; Kiley, H.; Mason, M.; Darmenova, K.

    2010-12-01

    As the renewable energy industry continues to grow so does the requirement for atmospheric modeling and analysis tools to maximize both wind and solar power. Renewable energy generation is variable however; presenting challenges for electrical grid operation and requires a variety of measures to adequately firm power. These measures include the production of non-renewable generation during times when renewables are not available. One strategy for minimizing the variability of renewable energy production is site diversity. Assuming that a network of renewable energy systems feed a common electrical grid, site diversity ensures that when one system on the network has a reduction in generation others on the same grid make up the difference. The site-diversity strategy can be used to mitigate the intermittency in alternative energy production systems while still maximizing saleable energy. The Renewable Energy Network Optimization Tool (ReNOT) has recently been developed to study the merits of site optimization for wind farms. The modeling system has a plug-in architecture that allows us to accommodate a wide variety of renewable energy system designs and performance metrics. The Weather Research and Forecasting (WRF) mesoscale model is applied to generate high-resolution wind databases to support the site selection of wind farms. These databases are generated on High Performance Computing systems such as the Rocky Mountain Supercomputing Center (RMSC). The databases are then accessed by ReNOT and an optimized site selection is developed. We can accommodate numerous constraints (e.g., number of sites, the geographic extent of the optimization, proximity to high-voltage transport lines, etc.). As part of our collaboration with RMSC and the State of Montana a study was performed to estimate the optimal locations of a network of wind farms. Comparisons were made to four existing wind farm locations in Montana including Glacier with a 210 MW name plate capacity, Horseshoe Bend with a total capacity of 9 MW, Diamond Willow with a capacity of 20MW and Judith Gap with a total capacity of 135 MW. The goal of this study was to see if ReNOT could find a four site network that made more effective use of the existing four site network of wind farms' 374 MW nameplate capacity. We developed three different metrics in which to pick sites. Metric 3 (M3) picks sites based on the previous day's mean power, and accounts for short-term variability (i.e., 1 hour). M3 attempts to approximate usable power by minimizing ramping events which are so important to industry. In addition we investigated several performance metrics including Mean Power, Usable Power, and ramping event frequency. A ramping event is defined as an increase or decrease in power production over the course of one hour. Of interest was the frequency of ramping events that exceeded 10% of total capacity for the network. Networks with few ramping events are markedly superior to networks producing otherwise identical aggregate power. The optimization was run over the 15-year period of hub-height wind data (40 meters AGL). The ReNOT derived network produces 58% more usable power than the four existing and operating wind farms. In addition, the optimized four site network produces three times fewer significant ramping events.

  13. Embedded solution for a microwave moisture meter

    USDA-ARS?s Scientific Manuscript database

    In this paper, the conversion of a PC or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter is based on the free-space transmission measurement technique and uses low-intensity microwaves to measure the attenuation and p...

  14. A system for the real time, direct measurement of natural gas flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sowell, T.

    1995-12-31

    PMI/Badger Meter, Inc. with partial sponsorship from the Gas Research Institute, has designed and developed direct measurement total energy flow metering instrumentation. As industry demands for improved accuracy and speed of measurement have increased so has the complexity of the overall hardware and software systems. Considering traditional system approaches, few companies have the in house capability of maintaining a complete system. This paper addresses efforts to implement a direct, total gas energy flow metering system which is simple to use and cost effective.

  15. Application of semi-active RFID power meter in automatic verification pipeline and intelligent storage system

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    In this paper, the semi-active RFID watt-hour meter is applied to automatic test lines and intelligent warehouse management, from the transmission system, test system and auxiliary system, monitoring system, realize the scheduling of watt-hour meter, binding, control and data exchange, and other functions, make its more accurate positioning, high efficiency of management, update the data quickly, all the information at a glance. Effectively improve the quality, efficiency and automation of verification, and realize more efficient data management and warehouse management.

  16. Methods and Tools for Ethical Usability

    NASA Astrophysics Data System (ADS)

    Kavathatzopoulos, Iordanis; Kostrzewa, Agata; Laaksoharju, Mikael

    The objectives of the tutorial are to provide knowledge of basic ethical, psychological and organizational theories that are relevant to consider ethical aspects during design and use of IT systems; knowledge and skills about handling and solving ethical problems in connection with design and use of IT-systems; and skills in using questionnaires, surveys, interviews and the like in connection with software development and IT-use. It contains lectures, workshop and exercises; use of special tools to identify and consider IT ethical issues during planning, construction, installation and use of IT systems; and group exercises where the participants train their ethical skills on IT ethical conflicts and problems. Intended participants are system developers, purchasers, usability experts, academics, HCI teachers.

  17. Usability Testing for e-Resource Discovery: How Students Find and Choose e-Resources Using Library Web Sites

    ERIC Educational Resources Information Center

    Fry, Amy; Rich, Linda

    2011-01-01

    In early 2010, library staff at Bowling Green State University (BGSU) in Ohio designed and conducted a usability study of key parts of the library web site, focusing on the web pages generated by the library's electronic resources management system (ERM) that list and describe the library's databases. The goal was to discover how users find and…

  18. United States Navy Health Care Providers' Attitudes and Satisfaction toward the Usability of the Navy's Primary Learning Portal and Learning Management System

    ERIC Educational Resources Information Center

    Catanese, Anthony Peter

    2013-01-01

    The purpose of this study was to investigate if the architectural design factors affected usability of Navy Knowledge Online (NKO) technology along with the user dissatisfaction associated through restricted achievements of online education and training. In this study, attitudes, satisfaction, obstacles, and providers' demographics were also…

  19. Applying Human Factors Principles to Mitigate Usability Issues Related to Embedded Assumptions in Health Information Technology Design

    PubMed Central

    Lowry, Svetlana Z; Patterson, Emily S

    2014-01-01

    Background There is growing recognition that design flaws in health information technology (HIT) lead to increased cognitive work, impact workflows, and produce other undesirable user experiences that contribute to usability issues and, in some cases, patient harm. These usability issues may in turn contribute to HIT utilization disparities and patient safety concerns, particularly among “non-typical” HIT users and their health care providers. Health care disparities are associated with poor health outcomes, premature death, and increased health care costs. HIT has the potential to reduce these disparate outcomes. In the computer science field, it has long been recognized that embedded cultural assumptions can reduce the usability, usefulness, and safety of HIT systems for populations whose characteristics differ from “stereotypical” users. Among these non-typical users, inappropriate embedded design assumptions may contribute to health care disparities. It is unclear how to address potentially inappropriate embedded HIT design assumptions once detected. Objective The objective of this paper is to explain HIT universal design principles derived from the human factors engineering literature that can help to overcome potential usability and/or patient safety issues that are associated with unrecognized, embedded assumptions about cultural groups when designing HIT systems. Methods Existing best practices, guidance, and standards in software usability and accessibility were subjected to a 5-step expert review process to identify and summarize those best practices, guidance, and standards that could help identify and/or address embedded design assumptions in HIT that could negatively impact patient safety, particularly for non-majority HIT user populations. An iterative consensus-based process was then used to derive evidence-based design principles from the data to address potentially inappropriate embedded cultural assumptions. Results Design principles that may help identify and address embedded HIT design assumptions are available in the existing literature. Conclusions Evidence-based HIT design principles derived from existing human factors and informatics literature can help HIT developers identify and address embedded cultural assumptions that may underlie HIT-associated usability and patient safety concerns as well as health care disparities. PMID:27025349

  20. TRAK App Suite: A Web-Based Intervention for Delivering Standard Care for the Rehabilitation of Knee Conditions.

    PubMed

    Spasić, Irena; Button, Kate; Divoli, Anna; Gupta, Satyam; Pataky, Tamas; Pizzocaro, Diego; Preece, Alun; van Deursen, Robert; Wilson, Chris

    2015-10-16

    Standard care for the rehabilitation of knee conditions involves exercise programs and information provision. Current methods of rehabilitation delivery struggle to keep up with large volumes of patients and the length of treatment required to maximize the recovery. Therefore, the development of novel interventions to support self-management is strongly recommended. Such interventions need to include information provision, goal setting, monitoring, feedback, and support groups, but the most effective methods of their delivery are poorly understood. The Internet provides a medium for intervention delivery with considerable potential for meeting these needs. The objective of this study was to demonstrate the feasibility of a Web-based app and to conduct a preliminary review of its practicability as part of a complex medical intervention in the rehabilitation of knee disorders. This paper describes the development, implementation, and usability of such an app. An interdisciplinary team of health care professionals and researchers, computer scientists, and app developers developed the TRAK app suite. The key functionality of the app includes information provision, a three-step exercise program based on a standard care for the rehabilitation of knee conditions, self-monitoring with visual feedback, and a virtual support group. There were two types of stakeholders (patients and physiotherapists) that were recruited for the usability study. The usability questionnaire was used to collect both qualitative and quantitative information on computer and Internet usage, task completion, and subjective user preferences. A total of 16 patients and 15 physiotherapists participated in the usability study. Based on the System Usability Scale, the TRAK app has higher perceived usability than 70% of systems. Both patients and physiotherapists agreed that the given Web-based approach would facilitate communication, provide information, help recall information, improve understanding, enable exercise progression, and support self-management in general. The Web app was found to be easy to use and user satisfaction was very high. The TRAK app suite can be accessed at http://apps.facebook.com/kneetrak/. The usability study suggests that a Web-based intervention is feasible and acceptable in supporting self-management of knee conditions.

  1. Applying Human Factors Principles to Mitigate Usability Issues Related to Embedded Assumptions in Health Information Technology Design.

    PubMed

    Gibbons, Michael C; Lowry, Svetlana Z; Patterson, Emily S

    2014-12-18

    There is growing recognition that design flaws in health information technology (HIT) lead to increased cognitive work, impact workflows, and produce other undesirable user experiences that contribute to usability issues and, in some cases, patient harm. These usability issues may in turn contribute to HIT utilization disparities and patient safety concerns, particularly among "non-typical" HIT users and their health care providers. Health care disparities are associated with poor health outcomes, premature death, and increased health care costs. HIT has the potential to reduce these disparate outcomes. In the computer science field, it has long been recognized that embedded cultural assumptions can reduce the usability, usefulness, and safety of HIT systems for populations whose characteristics differ from "stereotypical" users. Among these non-typical users, inappropriate embedded design assumptions may contribute to health care disparities. It is unclear how to address potentially inappropriate embedded HIT design assumptions once detected. The objective of this paper is to explain HIT universal design principles derived from the human factors engineering literature that can help to overcome potential usability and/or patient safety issues that are associated with unrecognized, embedded assumptions about cultural groups when designing HIT systems. Existing best practices, guidance, and standards in software usability and accessibility were subjected to a 5-step expert review process to identify and summarize those best practices, guidance, and standards that could help identify and/or address embedded design assumptions in HIT that could negatively impact patient safety, particularly for non-majority HIT user populations. An iterative consensus-based process was then used to derive evidence-based design principles from the data to address potentially inappropriate embedded cultural assumptions. Design principles that may help identify and address embedded HIT design assumptions are available in the existing literature. Evidence-based HIT design principles derived from existing human factors and informatics literature can help HIT developers identify and address embedded cultural assumptions that may underlie HIT-associated usability and patient safety concerns as well as health care disparities.

  2. TRAK App Suite: A Web-Based Intervention for Delivering Standard Care for the Rehabilitation of Knee Conditions

    PubMed Central

    Divoli, Anna; Gupta, Satyam; Pataky, Tamas; Pizzocaro, Diego; Preece, Alun; van Deursen, Robert; Wilson, Chris

    2015-01-01

    Background Standard care for the rehabilitation of knee conditions involves exercise programs and information provision. Current methods of rehabilitation delivery struggle to keep up with large volumes of patients and the length of treatment required to maximize the recovery. Therefore, the development of novel interventions to support self-management is strongly recommended. Such interventions need to include information provision, goal setting, monitoring, feedback, and support groups, but the most effective methods of their delivery are poorly understood. The Internet provides a medium for intervention delivery with considerable potential for meeting these needs. Objective The objective of this study was to demonstrate the feasibility of a Web-based app and to conduct a preliminary review of its practicability as part of a complex medical intervention in the rehabilitation of knee disorders. This paper describes the development, implementation, and usability of such an app. Methods An interdisciplinary team of health care professionals and researchers, computer scientists, and app developers developed the TRAK app suite. The key functionality of the app includes information provision, a three-step exercise program based on a standard care for the rehabilitation of knee conditions, self-monitoring with visual feedback, and a virtual support group. There were two types of stakeholders (patients and physiotherapists) that were recruited for the usability study. The usability questionnaire was used to collect both qualitative and quantitative information on computer and Internet usage, task completion, and subjective user preferences. Results A total of 16 patients and 15 physiotherapists participated in the usability study. Based on the System Usability Scale, the TRAK app has higher perceived usability than 70% of systems. Both patients and physiotherapists agreed that the given Web-based approach would facilitate communication, provide information, help recall information, improve understanding, enable exercise progression, and support self-management in general. The Web app was found to be easy to use and user satisfaction was very high. The TRAK app suite can be accessed at http://apps.facebook.com/kneetrak/. Conclusions The usability study suggests that a Web-based intervention is feasible and acceptable in supporting self-management of knee conditions. PMID:26474643

  3. Assessment of the Need for an Improved Inspection Program for Master Meter Systems

    DOT National Transportation Integrated Search

    2002-01-01

    Gas master meter systems are small intrastate gas distribution systems providing natural gas purchased from local gas utilities (or, rarely, gas transmission systems) to consumers in connection with the rental, leasing, or management of real property...

  4. Electric-drive tractability indicator integrated in hybrid electric vehicle tachometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamai, Goro; Zhou, Jing; Weslati, Feisel

    An indicator, system and method of indicating electric drive usability in a hybrid electric vehicle. A tachometer is used that includes a display having an all-electric drive portion and a hybrid drive portion. The all-electric drive portion and the hybrid drive portion share a first boundary which indicates a minimum electric drive usability and a beginning of hybrid drive operation of the vehicle. The indicated level of electric drive usability is derived from at least one of a percent battery discharge, a percent maximum torque provided by the electric drive, and a percent electric drive to hybrid drive operating costmore » for the hybrid electric vehicle.« less

  5. Safety status system for operating room devices.

    PubMed

    Guédon, Annetje C P; Wauben, Linda S G L; Overvelde, Marlies; Blok, Joleen H; van der Elst, Maarten; Dankelman, Jenny; van den Dobbelsteen, John J

    2014-01-01

    Since the increase of the number of technological aids in the operating room (OR), equipment-related incidents have come to be a common kind of adverse events. This underlines the importance of adequate equipment management to improve the safety in the OR. A system was developed to monitor the safety status (periodic maintenance and registered malfunctions) of OR devices and to facilitate the notification of malfunctions. The objective was to assess whether the system is suitable for use in an busy OR setting and to analyse its effect on the notification of malfunctions. The system checks automatically the safety status of OR devices through constant communication with the technical facility management system, informs the OR staff real-time and facilitates notification of malfunctions. The system was tested for a pilot period of six months in four ORs of a Dutch teaching hospital and 17 users were interviewed on the usability of the system. The users provided positive feedback on the usability. For 86.6% of total time, the localisation of OR devices was accurate. 62 malfunctions of OR devices were reported, an increase of 12 notifications compared to the previous year. The safety status system was suitable for an OR complex, both from a usability and technical point of view, and an increase of reported malfunctions was observed. The system eases monitoring the safety status of equipment and is a promising tool to improve the safety related to OR devices.

  6. Heuristic Evaluation on Mobile Interfaces: A New Checklist

    PubMed Central

    Yáñez Gómez, Rosa; Cascado Caballero, Daniel; Sevillano, José-Luis

    2014-01-01

    The rapid evolution and adoption of mobile devices raise new usability challenges, given their limitations (in screen size, battery life, etc.) as well as the specific requirements of this new interaction. Traditional evaluation techniques need to be adapted in order for these requirements to be met. Heuristic evaluation (HE), an Inspection Method based on evaluation conducted by experts over a real system or prototype, is based on checklists which are desktop-centred and do not adequately detect mobile-specific usability issues. In this paper, we propose a compilation of heuristic evaluation checklists taken from the existing bibliography but readapted to new mobile interfaces. Selecting and rearranging these heuristic guidelines offer a tool which works well not just for evaluation but also as a best-practices checklist. The result is a comprehensive checklist which is experimentally evaluated as a design tool. This experimental evaluation involved two software engineers without any specific knowledge about usability, a group of ten users who compared the usability of a first prototype designed without our heuristics, and a second one after applying the proposed checklist. The results of this experiment show the usefulness of the proposed checklist for avoiding usability gaps even with nontrained developers. PMID:25295300

  7. Evaluating the parent-adolescent communication toolkit: Usability and preliminary content effectiveness of an online intervention.

    PubMed

    Toombs, Elaine; Unruh, Anita; McGrath, Patrick

    2018-01-01

    This study aimed to assess the Parent-Adolescent Communication Toolkit, an online intervention designed to help improve parent communication with their adolescents. Participant preferences for two module delivery systems (sequential and unrestricted module access) were identified. Usability assessment of the PACT intervention was completed using pre-test and posttest comparisons. Usability data, including participant completion and satisfaction ratings were examined. Parents ( N  =   18) of adolescents were randomized to a sequential or unrestricted chapter access group. Parent participants completed pre-test measures, the PACT intervention and posttest measures. Participants provided feedback for the intervention to improve modules and provided usability ratings. Adolescent pre- and posttest ratings were evaluated. Usability ratings were high and parent feedback was positive. The sequential module access groups rated the intervention content higher and completed more content than the unrestricted chapter access group, indicating support for the sequential access design. Parent mean posttest communication scores were significantly higher ( p  <   .05) than pre-test scores. No significant differences were detected for adolescent participants. Findings suggest that the Parent-Adolescent Communication Toolkit has potential to improve parent-adolescent communication but further effectiveness assessment is required.

  8. Empirical studies on usability of mHealth apps: a systematic literature review.

    PubMed

    Zapata, Belén Cruz; Fernández-Alemán, José Luis; Idri, Ali; Toval, Ambrosio

    2015-02-01

    The release of smartphones and tablets, which offer more advanced communication and computing capabilities, has led to the strong emergence of mHealth on the market. mHealth systems are being used to improve patients' lives and their health, in addition to facilitating communication between doctors and patients. Researchers are now proposing mHealth applications for many health conditions such as dementia, autism, dysarthria, Parkinson's disease, and so on. Usability becomes a key factor in the adoption of these applications, which are often used by people who have problems when using mobile devices and who have a limited experience of technology. The aim of this paper is to investigate the empirical usability evaluation processes described in a total of 22 selected studies related to mHealth applications by means of a Systematic Literature Review. Our results show that the empirical evaluation methods employed as regards usability could be improved by the adoption of automated mechanisms. The evaluation processes should also be revised to combine more than one method. This paper will help researchers and developers to create more usable applications. Our study demonstrates the importance of adapting health applications to users' need.

  9. Effect of disinfectants on glucose monitors.

    PubMed

    Mahoney, John J; Lim, Christine G

    2012-01-01

    Monitoring blood glucose levels is an integral part of routine diabetes management. To minimize the risk of transmission of bloodborne pathogens during monitoring, the Centers for Disease Control and Prevention (CDC) recommends that glucose meters be disinfected after each use whenever they are used to test multiple patients. The objective of this study is to assess the compatibility of some common disinfectants with certain blood glucose meter systems. We tested six disinfectants for adverse impact on meter performance or the exterior meter surfaces. The disinfectants tested were 0.525% sodium hypochlorite, 20% 2-propanol and 10% ethanol, 17.2% isopropanol, 55% isopropanol, 70% isopropanol, and hydrogen peroxide. To assess meter performance, we tested OneTouch® Ultra® blood glucose monitoring systems with control solution before and after application of either water or disinfectant. To assess the effect on exterior meter surfaces, we performed a soaking test to simulate long-term exposure to disinfectant. Paired t-test results showed that the control solution data associated with disinfectant and with water application were not significantly different for each meter type. However, most of the meter types were adversely affected by hydrogen peroxide and/or by the higher concentrations of alcohol-based disinfectants. Although none of the six disinfectants affected meter performance, hydrogen peroxide and isopropanol >20% adversely affected the exterior surfaces of the tested meters. When complying with CDC instructions for meter disinfection, users should use caution and choose disinfectants that have been validated by the meter manufacturer. © 2012 Diabetes Technology Society.

  10. Effect of Disinfectants on Glucose Monitors

    PubMed Central

    Mahoney, John J; Lim, Christine G

    2012-01-01

    Background Monitoring blood glucose levels is an integral part of routine diabetes management. To minimize the risk of transmission of bloodborne pathogens during monitoring, the Centers for Disease Control and Prevention (CDC) recommends that glucose meters be disinfected after each use whenever they are used to test multiple patients. The objective of this study is to assess the compatibility of some common disinfectants with certain blood glucose meter systems. Methods We tested six disinfectants for adverse impact on meter performance or the exterior meter surfaces. The disinfectants tested were 0.525% sodium hypochlorite, 20% 2-propanol and 10% ethanol, 17.2% isopropanol, 55% isopropanol, 70% isopropanol, and hydrogen peroxide. To assess meter performance, we tested OneTouch® Ultra® blood glucose monitoring systems with control solution before and after application of either water or disinfectant. To assess the effect on exterior meter surfaces, we performed a soaking test to simulate long-term exposure to disinfectant. Results Paired t-test results showed that the control solution data associated with disinfectant and with water application were not significantly different for each meter type. However, most of the meter types were adversely affected by hydrogen peroxide and/or by the higher concentrations of alcohol-based disinfectants. Conclusions Although none of the six disinfectants affected meter performance, hydrogen peroxide and isopropanol >20% adversely affected the exterior surfaces of the tested meters. When complying with CDC instructions for meter disinfection, users should use caution and choose disinfectants that have been validated by the meter manufacturer. PMID:22401326

  11. Metering Plan: Intelligent Operational Strategies Through Enhanced Metering Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, Jason E.

    The Sustainability Program at Pacific Northwest National Laboratory (PNNL) has adopted a “triple-bottom-line” approach of environmental stewardship, social responsibility, and economic prosperity to its operations. Metering at PNNL works in support of all three, specifically to measure and inform building energy use and greenhouse gas emissions and minimize water use. The foundation for metering at PNNL is a core goal set, which consists of four objectives: providing accurate data without interruption, analyzing data while it is still new, providing actionable recommendations to operations management, and ensuring PNNL’s compliance with contract metering requirements. These core objectives guide the decisions that wemore » make during annual planning and as we operate throughout the year. This 2016 edition of the Metering Plan conveys the metering practices for and vision of the Sustainability Program. Changes in this plan from the 2015 edition include updated tables and an enhanced discussion on energy tracking systems used at PNNL. This plan also discusses updated benchmarking strategies using PNNL’s graphics and analytics tool, BuildingOS by Lucid Design Group. This plan presents our progress toward the metering goals shared by all federal agencies and highlights our successful completion of metering requirements. Currently, PNNL is fully compliant with the applicable legislative and Executive Order metering requirements. PNNL’s approach to the installation of new meters will be discussed. Perhaps most importantly, this plan details the analysis techniques utilized at PNNL that rely on the endless streams of data newly available as a result of increased meter deployment over the last several years. Previous Metering Plans have documented specific meter connection schemes as PNNL focused on deploying meters in a first step toward managing energy and water use. This plan serves not only to highlight PNNL’s successful completion of agency metering goals, but also can be used as a guideline for meter installation and data analysis.« less

  12. 49 CFR 325.23 - Type of measurement systems which may be used.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... may be used. The sound level measurement system must meet or exceed the requirements of American National Standard Specification for Sound Level Meters (ANSI S1.4-1971), approved April 27, 1971, issued by..., New York, New York, 10018. (a) A Type 1 sound level meter; (b) A Type 2 sound level meter; or (c) A...

  13. Space Transportation Infrastructure Supported By Propellant Depots

    NASA Technical Reports Server (NTRS)

    Smitherman, David; Woodcock, Gordon

    2011-01-01

    A space transportation infrastructure is described that utilizes propellant depots to support all foreseeable missions in the Earth-Moon vicinity and deep space out to Mars. The infrastructure utilizes current expendable launch vehicles such as the Delta IV Heavy, Atlas V, and Falcon 9, for all crew, cargo, and propellant launches to orbit. Propellant launches are made to a Low-Earth-Orbit (LEO) Depot and an Earth-Moon Lagrange Point 1 (L1) Depot to support new reusable in-space transportation vehicles. The LEO Depot supports missions to Geosynchronous Earth Orbit (GEO) for satellite servicing, and to L1 for L1 Depot missions. The L1 Depot supports Lunar, Earth-Sun L2 (ESL2), Asteroid, and Mars missions. A Mars Orbital Depot is also described to support ongoing Mars missions. New concepts for vehicle designs are presented that can be launched on current 5-meter diameter expendable launch vehicles. These new reusable vehicle concepts include a LEO Depot, L1 Depot, and Mars Orbital Depot based on International Space Station (ISS) heritage hardware. The high-energy depots at L1 and Mars orbit are compatible with, but do not require, electric propulsion tug use for propellant and/or cargo delivery. New reusable in-space crew transportation vehicles include a Crew Transfer Vehicle (CTV) for crew transportation between the LEO Depot and the L1 Depot, a new reusable Lunar Lander for crew transportation between the L1 Depot and the lunar surface, and a Deep Space Habitat (DSH) to support crew missions from the L1 Depot to ESL2, Asteroid, and Mars destinations. A 6 meter diameter Mars lander concept is presented that can be launched without a fairing based on the Delta IV heavy Payload Planners Guide, which indicates feasibility of a 6.5 meter fairing. This lander would evolve to re-usable operations when propellant production is established on Mars. Figure 1 provides a summary of the possible missions this infrastructure can support. Summary mission profiles are presented for each primary mission capability. These profiles are the basis for propellant loads, numbers of vehicles/stages and launches for each mission capability. Data includes the number of launches required for each mission utilizing current expendable launch vehicle systems, and concluding remarks include ideas for reducing the number of launches through incorporation of heavy-lift launch vehicles, solar electric propulsion, and other transportation support concepts.

  14. A task-specific interactive game-based virtual reality rehabilitation system for patients with stroke: a usability test and two clinical experiments.

    PubMed

    Shin, Joon-Ho; Ryu, Hokyoung; Jang, Seong Ho

    2014-03-06

    Virtual reality (VR) is not commonly used in clinical rehabilitation, and commercial VR gaming systems may have mixed effects in patients with stroke. Therefore, we developed RehabMaster™, a task-specific interactive game-based VR system for post-stroke rehabilitation of the upper extremities, and assessed its usability and clinical efficacy. A participatory design and usability tests were carried out for development of RehabMaster with representative user groups. Two clinical trials were then performed. The first was an observational study in which seven patients with chronic stroke received 30 minutes of RehabMaster intervention per day for two weeks. The second was a randomised controlled trial of 16 patients with acute or subacute stroke who received 10 sessions of conventional occupational therapy only (OT-only group) or conventional occupational therapy plus 20 minutes of RehabMaster intervention (RehabMaster + OT group). The Fugl-Meyer Assessment score (FMA), modified Barthel Index (MBI), adverse effects, and drop-out rate were recorded. The requirements of a VR system for stroke rehabilitation were established and incorporated into RehabMaster. The reported advantages from the usability tests were improved attention, the immersive flow experience, and individualised intervention. The first clinical trial showed that the RehabMaster intervention improved the FMA (P = .03) and MBI (P = .04) across evaluation times. The second trial revealed that the addition of RehabMaster intervention tended to enhance the improvement in the FMA (P = .07) but did not affect the improvement in the MBI. One patient with chronic stroke left the trial, and no adverse effects were reported. The RehabMaster is a feasible and safe VR system for enhancing upper extremity function in patients with stroke.

  15. A task-specific interactive game-based virtual reality rehabilitation system for patients with stroke: a usability test and two clinical experiments

    PubMed Central

    2014-01-01

    Background Virtual reality (VR) is not commonly used in clinical rehabilitation, and commercial VR gaming systems may have mixed effects in patients with stroke. Therefore, we developed RehabMaster™, a task-specific interactive game-based VR system for post-stroke rehabilitation of the upper extremities, and assessed its usability and clinical efficacy. Methods A participatory design and usability tests were carried out for development of RehabMaster with representative user groups. Two clinical trials were then performed. The first was an observational study in which seven patients with chronic stroke received 30 minutes of RehabMaster intervention per day for two weeks. The second was a randomised controlled trial of 16 patients with acute or subacute stroke who received 10 sessions of conventional occupational therapy only (OT-only group) or conventional occupational therapy plus 20 minutes of RehabMaster intervention (RehabMaster + OT group). The Fugl-Meyer Assessment score (FMA), modified Barthel Index (MBI), adverse effects, and drop-out rate were recorded. Results The requirements of a VR system for stroke rehabilitation were established and incorporated into RehabMaster. The reported advantages from the usability tests were improved attention, the immersive flow experience, and individualised intervention. The first clinical trial showed that the RehabMaster intervention improved the FMA (P = .03) and MBI (P = .04) across evaluation times. The second trial revealed that the addition of RehabMaster intervention tended to enhance the improvement in the FMA (P = .07) but did not affect the improvement in the MBI. One patient with chronic stroke left the trial, and no adverse effects were reported. Conclusions The RehabMaster is a feasible and safe VR system for enhancing upper extremity function in patients with stroke. PMID:24597650

  16. Intellectual Production Supervision Perform based on RFID Smart Electricity Meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    This topic develops the RFID intelligent electricity meter production supervision project management system. The system is designed for energy meter production supervision in the management of the project schedule, quality and cost information management requirements in RFID intelligent power, and provide quantitative information more comprehensive, timely and accurate for supervision engineer and project manager management decisions, and to provide technical information for the product manufacturing stage file. From the angle of scheme analysis, design, implementation and test, the system development of production supervision project management system for RFID smart meter project is discussed. Focus on the development of the system, combined with the main business application and management mode at this stage, focuses on the energy meter to monitor progress information, quality information and cost based information on RFID intelligent power management function. The paper introduces the design scheme of the system, the overall client / server architecture, client oriented graphical user interface universal, complete the supervision of project management and interactive transaction information display, the server system of realizing the main program. The system is programmed with C# language and.NET operating environment, and the client and server platforms use Windows operating system, and the database server software uses Oracle. The overall platform supports mainstream information and standards and has good scalability.

  17. Two years of unintended consequences: introducing an electronic health record system in a hospice in Scotland.

    PubMed

    Snowden, Austyn; Kolb, Hildegard

    2017-05-01

    To explore the impact of implementing an electronic health record system on staff at a Scottish hospice. Electronic health records are broadly considered preferable to paper-based systems. However, changing from one system to the other is difficult. This study analysed the impact of this change in a Scottish hospice. Naturalistic prospective repeated-measures mixed-methods approach. Data on the usability of the system, staff engagement and staff experience were obtained at four time points spanning 30 months from inception. Quantitative data were obtained from surveys, and qualitative from concurrent analysis of free-text comments and focus group. Participants were all 150 employees of a single hospice in Scotland. Both system usability and staff engagement scores decreased for the first two years before recovering at 30 months. Staff experience data pointed to two main challenges: (1) Technical issues, with subthemes of accessibility and usability. (2) Cultural issues, with subthemes of time, teamwork, care provision and perception of change. It took 30 months for system usability and staff engagement scores to rise, after falling significantly for the first two years. The unintended outcomes of implementation included challenges to the way the patient story was both recorded and communicated. Nevertheless, this process of change was found to be consistent with the 'J-curve' theory of organisational change, and as such, it is both predictable and manageable for other organisations. It is known that implementing an electronic health record system is complex. This paper puts parameters on this complexity by defining both the nature of the complexity ('J' curve) and the time taken for the organisation to begin recovery from the challenges (two years). Understanding these parameters will help health organisations across the world plan more strategically. © 2016 John Wiley & Sons Ltd.

  18. Rockot - a new cost effective launcher for small satellites

    NASA Astrophysics Data System (ADS)

    Mosenkis, Regina

    1996-01-01

    Daimler-Benz Aerospace of Germany and the Russian Khrunichev State Research and Production Space Center have formed a jointly owned EUROCKOT Launch Services GmbH to offer worldwide cost effective launch services for the ROCKOT launch vehicle. ROCKOT, produced by Khrunichev, builder of the famous PROTON launcher, aims at the market of small and medium size satellites ranging from 300 to 1800 kg to be launched into low earth or sunsynchronous orbits. These comprize scientific, earth observation and polar meteorological satellites as well as the new generation of small communication satellites in low earth orbits, known as the ``Constellations''. ROCKOT is a three stage liquid propellant launch vehicle, composed of a former Russian SS 19 strategic missile, which has been withdrawn from military use, and a highly sophisticated, flight-proven upper stage named Breeze, which is particularly suited for a variety of civic and commercial space applications. Usable payload envelope has a length of 4.75 meters and a maximum diameter of 2.26 meters for accomodating the payload within the payload fairing. ROCKOT can also accomodate multiple payloads which can be deployed into the same or different orbits. So far ROCKOT has been successfully launched three times from Baikonur. The commercial launch services on ROCKOT from the Plesetsk launch site, Russia, will begin in 1997 and will be available worldwide at a highly competitive price.

  19. Ramp meter design manual

    DOT National Transportation Integrated Search

    2000-01-01

    Caltrans is committed to using ramp metering as an effective traffic management strategy to maintain an efficient freeway system and protect the investment made in constructing freeways by keeping them operating at or near capacity. Ramp Metering is ...

  20. The effect of touch-key size on the usability of In-Vehicle Information Systems and driving safety during simulated driving.

    PubMed

    Kim, Heejin; Kwon, Sunghyuk; Heo, Jiyoon; Lee, Hojin; Chung, Min K

    2014-05-01

    Investigating the effect of touch-key size on usability of In-Vehicle Information Systems (IVISs) is one of the most important research issues since it is closely related to safety issues besides its usability. This study investigated the effects of the touch-key size of IVISs with respect to safety issues (the standard deviation of lane position, the speed variation, the total glance time, the mean glance time, the mean time between glances, and the mean number of glances) and the usability of IVISs (the task completion time, error rate, subjective preference, and NASA-TLX) through a driving simulation. A total of 30 drivers participated in the task of entering 5-digit numbers with various touch-key sizes while performing simulated driving. The size of the touch-key was 7.5 mm, 12.5 mm, 17.5 mm, 22.5 mm and 27.5 mm, and the speed of driving was set to 0 km/h (stationary state), 50 km/h and 100 km/h. As a result, both the driving safety and the usability of the IVISs increased as the touch-key size increased up to a certain size (17.5 mm in this study), at which they reached asymptotes. We performed Fitts' law analysis of our data, and this revealed that the data from the dual task experiment did not follow Fitts' law. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  1. Designing Home-Based Telemedicine Systems for the Geriatric Population: An Empirical Study.

    PubMed

    Narasimha, Shraddhaa; Agnisarman, Sruthy; Chalil Madathil, Kapil; Gramopadhye, Anand; McElligott, James T

    2018-02-01

    Background and Introduction: Telemedicine, the process of providing healthcare remotely using communication devices, has the potential to be useful for the geriatric population when specifically designed for this age group. This study explored the design of four video telemedicine systems currently available and outlined issues with these systems that impact usability among the geriatric population. Based on the results, design suggestions were developed to improve telemedicine systems for this population. Using a between-subjects experimental design, the study considered four telemedicine systems used in Medical University of South Carolina. The study was conducted at a local retirement home. The participant pool consisted of 40 adults, 60 years or older. The dependent measures used were the mean times for telemedicine session initiation and video session, mean number of errors, post-test satisfaction ratings, the NASA-Task Load Index (NASA-TLX) workload measures, and the IBM-Computer Systems Usability Questionnaire measures. Statistical significance was found among the telemedicine systems' initiation times. The analysis of the qualitative data revealed several issues, including lengthy e-mail content, icon placement, and chat box design, which affect the usability of these systems for the geriatric population. Human factor-based design modifications, including short, precise e-mail content, appropriately placed icons, and the inclusion of instructions, are recommended to address the issues found in the qualitative study.

  2. Design and implementation of Remote Digital Energy Meter (RDEM) based on GSM technology

    NASA Astrophysics Data System (ADS)

    Khan, Muhammad Waseem; Wang, Jie; Irfan, Muhammad; Shiraz, M.; Khan, Ali Hassan

    2017-11-01

    Electric power is one of the basic requirement for socio economic and social prosperity of any country, which is mainly employs for domestic, industrial and agricultural sectors. The primary purpose of this research is to design and implement an energy meter which can remotely control and monitor through global system for mobile (GSM) communication technology. For this purpose, a single phase or three phase digital energy meters are used to add on different advanced modules. The energy meter can be activated and display power consumption information at the consumer premises on liquid crystal display and through a short message service (SMS) by using GSM technology. At the power sending end, an energy meter can be remotely control and monitor through GSM technology without any system disturbances. This study will lead to make the system easier, economical, reliable and efficient for the electrical department.

  3. Comparative Analysis of Smart Meters Deployment Business Models on the Example of the Russian Federation Markets

    NASA Astrophysics Data System (ADS)

    Daminov, Ildar; Tarasova, Ekaterina; Andreeva, Tatyana; Avazov, Artur

    2016-02-01

    This paper presents the comparison of smart meter deployment business models to determine the most suitable option providing smart meters deployment. Authors consider 3 main business model of companies: distribution grid company, energy supplier (energosbyt) and metering company. The goal of the article is to compare the business models of power companies from massive smart metering roll out in power system of Russian Federation.

  4. Grid-Connected Distributed Generation: Compensation Mechanism Basics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aznar, Alexandra Y; Zinaman, Owen R

    2017-10-02

    This short report defines compensation mechanisms for grid-connected, behind-the-meter distributed generation (DG) systems as instruments that comprise three core elements: (1) metering and billing arrangements, (2) sell rate design, and (3) retail rate design. This report describes metering and billing arrangements, with some limited discussion of sell rate design. We detail the three possible arrangements for metering and billing of DG: net energy metering (NEM); buy all, sell all; and net billing.

  5. Dosvox Usability: recommendations for improving interaction of blind people with the web using the system.

    PubMed

    de Souza, Edson Rufino; de Freitas, Sydney Fernandes

    2012-01-01

    At present, it is recognized that the Internet plays key role in universalization of opportunities in society in which we live. For people with disabilities, the content must be accessible in all websites, but the assistive technologies used must be adequate to the specific needs of people with disabilities. Dosvox is a free system developed in the Universidade Federal do Rio de Janeiro (UFRJ) specially designed for blind people and used by them in the performance of their tasks with the use of computers. Previously, through exploratory research based on the observation of the interaction of blind students with the Web, usability problems were identified in the Dosvox interface and in the Webvox, the Web browser included in the system, and these problems were related to the fact that the interface is designed in accordance with the mental model of these Information Technology professionals. This study consolidate the problems in earlier phases of the research, link the results with usability heuristics of Nielsen and propose several improvements to Dosvox and its development process.

  6. Sentiment of Search: KM and IT for User Expectations

    NASA Technical Reports Server (NTRS)

    Berndt, Sarah Ann; Meza, David

    2014-01-01

    User perceived value is the number one indicator of a successful implementation of KM and IT collaborations. The system known as "Search" requires more strategy and workflow that a mere data dump or ungoverned infrastructure can provide. Monitoring of user sentiment can be a driver for providing objective measures of success and justifying changes to the user interface. The dynamic nature of information technology makes traditional usability metrics difficult to identify, yet easy to argue against. There is little disagreement, however, on the criticality of adapting to user needs and expectations. The Systems Usability Scale (SUS), developed by John Brook in 1986 has become an industry standard for usability engineering. The first phase of a modified SUS, polls the sentiment of representative users of the JSC Search system. This information can be used to correlate user determined value with types of information sought and how the system is (or is not) meeting expectations. Sentiment analysis by way of the SUS assists an organization in identification and prioritization of the KM and IT variables impacting user perceived value. A secondary, user group focused analysis is the topic of additional work that demonstrates the impact of specific changes dictated by user sentiment.

  7. Further Exploration of the Classroom Video Analysis (CVA) Instrument as a Measure of Usable Knowledge for Teaching Mathematics: Taking a Knowledge System Perspective

    ERIC Educational Resources Information Center

    Kersting, Nicole B.; Sutton, Taliesin; Kalinec-Craig, Crystal; Stoehr, Kathleen Jablon; Heshmati, Saeideh; Lozano, Guadalupe; Stigler, James W.

    2016-01-01

    In this article we report further explorations of the classroom video analysis instrument (CVA), a measure of usable teacher knowledge based on scoring teachers' written analyses of classroom video clips. Like other researchers, our work thus far has attempted to identify and measure separable components of teacher knowledge. In this study we take…

  8. Rocket/Nimbus Sounder Comparison (RNSC)

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The experimental results for radiance and temperature differences in the Wallops Island comparisons indicate that the differences between satellite and rocket systems are of the same order of magnitude as the differences among the various satellite and rocket sounders. The Arcasondes produced usable data to about 50 km, while the Datasondes require design modification. The SIRS and IRIS soundings provided usable data to 30 mb; extension of these soundings was also investigated.

  9. Development and testing of highway storm-sewer flow measurement and recording system

    USGS Publications Warehouse

    Kilpatrick, F.A.; Kaehrle, W.R.; Hardee, Jack; Cordes, E.H.; Landers, M.N.

    1985-01-01

    A comprehensive study and development of measuring instruments and techniques for measuring all components of flow in a storm-sewer drainage system was undertaken by the U.S. Geological Survey under the sponsorship of the Federal Highway Administration. The study involved laboratory and field calibration and testing of measuring flumes, pipe insert meters, weirs, electromagnetic velocity meters as well as the development and calibration of pneumatic-bubbler pressure transducer head measuring systems. Tracer-dilution and acoustic flow meter measurements were used in field verification tests. A single micrologger was used to record data from all the above instruments as well as from a tipping-bucket rain gage and also to activate on command the electromagnetic velocity meter and tracer-dilution systems. (Author 's abstract)

  10. A framework for reporting on human factor/usability studies of health information technologies.

    PubMed

    Peute, Linda W; Driest, Keiko F; Marcilly, Romaric; Bras Da Costa, Sabrina; Beuscart-Zephir, Marie-Catherine; Jaspers, Monique W M

    2013-01-01

    Increasingly, studies are being published on the potential negative effect of introducing poor designed Health Information Technology (HIT) into clinical settings, relating to technology-induced errors and adverse events. Academic research on HIT design and evaluation is an extremely important source of information in providing new insights into factors contributing to successful system (re)design efforts, system user-friendliness and usability issues and safety critical aspects of HIT design. However, these studies have been inconsistent and incomprehensive in their reporting, complicating the appraisal of outcomes, generalizability of study findings, meta-analysis and harmonization of the available evidence. To improve identification of type of use errors and safety related issues regarding design and implementation of HIT, consensus on issues to be reported on in scientific publications is a necessary step forward. This study presents the first approach to a framework providing a set of principles to follow for comprehensive and unambiguous reporting of HIT design and usability evaluation studies with the objective to reduce variation, improve on the publication reporting quality and proper indexation of these studies. This framework may be helpful in expanding the knowledge base not only concerning the application of Human Factors (HF)/Usability studies of HIT but also improve the knowledge base of how to (re)design and implement effective, efficient and safe HIT.

  11. Enhancing TSM&O strategies through life cycle benefit/cost analysis : life cycle benefit/cost analysis & life cycle assessment of adaptive traffic control systems and ramp metering systems.

    DOT National Transportation Integrated Search

    2015-05-01

    The research team developed a comprehensive Benefit/Cost (B/C) analysis framework to evaluate existing and anticipated : intelligent transportation system (ITS) strategies, particularly, adaptive traffic control systems and ramp metering systems, : i...

  12. 40 CFR 205.54-2 - Sound data acquisition system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... meets the “fast” dynamic requirement of a precision sound level meter indicating meter system for the... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Sound data acquisition system. 205.54... data acquisition system. (a) Systems employing tape recorders and graphic level recorders may be...

  13. In the Loop: The Organization of Team-Based Communication in a Patient-Centered Clinical Collaboration System.

    PubMed

    Kurahashi, Allison M; Weinstein, Peter B; Jamieson, Trevor; Stinson, Jennifer N; Cafazzo, Joseph A; Lokuge, Bhadra; Morita, Plinio P; Cohen, Eyal; Rapoport, Adam; Bezjak, Andrea; Husain, Amna

    2016-03-24

    We describe the development and evaluation of a secure Web-based system for the purpose of collaborative care called Loop. Loop assembles the team of care with the patient as an integral member of the team in a secure space. The objectives of this paper are to present the iterative design of the separate views for health care providers (HCPs) within each patient's secure space and examine patients', caregivers', and HCPs' perspectives on this separate view for HCP-only communication. The overall research program includes cycles of ethnography, prototyping, usability testing, and pilot testing. This paper describes the usability testing phase that directly informed development. A descriptive qualitative approach was used to analyze participant perspectives that emerged during usability testing. During usability testing, we sampled 89 participants from three user groups: 23 patients, 19 caregivers, and 47 HCPs. Almost all perspectives from the three user groups supported the need for an HCP-only communication view. In an earlier prototype, the visual presentation caused confusion among HCPs when reading and composing messages about whether a message was visible to the patient. Usability testing guided us to design a more deliberate distinction between posting in the Patient and Team view and the Health Care Provider Only view at the time of composing a message, which once posted is distinguished by an icon. The team made a decision to incorporate an HCP-only communication view based on findings during earlier phases of work. During usability testing we tested the separate communication views, and all groups supported this partition. We spent considerable effort designing the partition; however, preliminary findings from the next phase of evaluation, pilot testing, show that the Patient and Team communication is predominantly being used. This demonstrates the importance of a subsequent phase of the clinical trial of Loop to validate the concept and design.

  14. Development of a distributed-parameter mathematical model for simulation of cryogenic wind tunnels

    NASA Technical Reports Server (NTRS)

    Tripp, J. S.

    1983-01-01

    A one-dimensional distributed-parameter dynamic model of a cryogenic wind tunnel was developed which accounts for internal and external heat transfer, viscous momentum losses, and slotted-test-section dynamics. Boundary conditions imposed by liquid-nitrogen injection, gas venting, and the tunnel fan were included. A time-dependent numerical solution to the resultant set of partial differential equations was obtained on a CDC CYBER 203 vector-processing digital computer at a usable computational rate. Preliminary computational studies were performed by using parameters of the Langley 0.3-Meter Transonic Cryogenic Tunnel. Studies were performed by using parameters from the National Transonic Facility (NTF). The NTF wind-tunnel model was used in the design of control loops for Mach number, total temperature, and total pressure and for determining interactions between the control loops. It was employed in the application of optimal linear-regulator theory and eigenvalue-placement techniques to develop Mach number control laws.

  15. Electronic physiologic and subjective data acquisition in home-dwelling heart failure patients: An assessment of patient use and perception of usability.

    PubMed

    Gardner, Cubby L; Flanagan, Michael C; Franklin, Cathy; John-Swayers, Cherly; Walsh-Pouch, Stacy; Bryant, F Joyce; Romano, Carol A; Gibbons, Susanne; De Jong, Marla; Hoang, Albert; Becher, Dorothy; Burke, Harry B

    2016-09-01

    The current approach to the outpatient management of heart failure involves patients recollecting what has happened to them since their last clinic visit. But patients' recollection of their symptoms may not be sufficiently accurate to optimally manage their disease. Most of what is known about heart failure is related to patients' diurnal symptoms and activities. Some mobile electronic technologies can operate continuously to collect data from the time patients go to bed until they get up in the morning. We were therefore interested to evaluate if patients would use a system of selected patient-facing devices to collect physiologic and subjective state data in and around the patients' period of sleep, and if there were differences in device use and perceptions of usability at the device level This descriptive observational study of home-dwelling patients with heart failure, between 21 and 90 years of age, enrolled in an outpatient heart failure clinic was conducted between December 2014 and June 2015. Patients received five devices, namely, body weight scale, blood pressure device, an iPad-based subjective states assessment, pulse oximeter, and actigraph, to collect their physiologic (body weight, blood pressure, heart rate, blood oxygen saturation, and physical activity) and subjective state data (symptoms and subjective states) at home for the next six consecutive nights. Use was defined as the ratio of observed use over expected use, where 1.0 is observed equals expected. Usability was determined by the overall System Usability Scale score. Participants were 39 clinical heart failure patients, mean age 68.1 (SD, 12.3), 72% male, 62% African American. The ratio of observed over expected use for the body weight scale, blood pressure device, iPad application, pulse oximeter and actigraph was 0.8, 1.0, 1.1, 0.9, and 1.9, respectively. The mean overall System Usability Scale score for each device were 84.5, 89.7, 85.7, 87.6, and 85.2, respectively. Patients were able to use all of the devices and they rated the usability of all the devices higher than expected. Our study provides support for at-home patient-collected physiologic and subjective state data. To our knowledge, this is the first study to assess the use and usability of electronic objective and subjective data collection devices in heart failure patients' homes overnight. Published by Elsevier Ireland Ltd.

  16. Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective

    PubMed Central

    van Lieshout, Remko; Pisters, Martijn F.; Vanwanseele, Benedicte; de Bie, Rob A.; Wouters, Eveline J.; Stukstette, Mirelle J.

    2016-01-01

    Background Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient’s compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices that provide real-time feedback. For a successful implementation, usability of the devices is a critical aspect and should be tested from a user’s perspective. Aim To describe the usability from the physical therapists’ and a patients’ perspective of Smartstep and OpenGo-Science to provide feedback on partial weight bearing during supervised rehabilitation of patients after lower-limb trauma or surgery. Methods In a convergent mixed-methods design, qualitative and quantitative data were collected. Usability was subdivided into user performance, satisfaction and acceptability. Patients prescribed with partial weight bearing and their physical therapists were asked to use SmartStep and OpenGo-Science during supervised rehabilitation. Usability was qualitatively tested by a think-aloud method and a semi-structured interview and quantitatively tested by the System-Usability-Scale (SUS) and closed questions. For the qualitative data thematic content analyses were used. Results Nine pairs of physical therapists and their patients participated. The mean SUS scores for patients and physical therapists were for SmartStep 70 and 53, and for OpenGo-Science 79 and 81, respectively. Scores were interpreted with the Curved Grading Scale. The qualitative data showed that there were mixed views and perceptions from patients and physical therapists on satisfaction and acceptability. Conclusion This study gives insight in the usability of two biofeedback devices from the patient’s and physical therapist’s perspective. The overall usability from both perspectives seemed to be acceptable for OpenGo-Science. For SmartStep, overall usability seemed only acceptable from the patient’s perspective. Implication The study findings could help clinicians to decide which biofeedback device is appropriate for their given situation and provide information for future development of biofeedback devices. PMID:27798674

  17. Implementation of the Agitated Behavior Scale in the Electronic Health Record.

    PubMed

    Wilson, Helen John; Dasgupta, Kritis; Michael, Kathleen

    The purpose of the study was to implement an Agitated Behavior Scale through an electronic health record and to evaluate the usability of the scale in a brain injury unit at a rehabilitation hospital. A quality improvement project was conducted in the brain injury unit at a large rehabilitation hospital with registered nurses as participants using convenience sampling. The project consisted of three phases and included education, implementation of the scale in the electronic health record, and administration of the survey questionnaire, which utilized the system usability scale. The Agitated Behavior Scale was found to be usable, and there was 92.2% compliance with the use of the electronic Electronic Agitated Behavior Scale. The Agitated Behavior Scale was effectively implemented in the electronic health record and was found to be usable in the assessment of agitation. Utilization of the scale through the electronic health record on a daily basis will allow for an early identification of agitation in patients with traumatic brain injury and enable prompt interventions to manage agitation.

  18. Usability testing of ANSWER: a web-based methotrexate decision aid for patients with rheumatoid arthritis

    PubMed Central

    2013-01-01

    Background Decision aids are evidence-based tools designed to inform people of the potential benefit and harm of treatment options, clarify their preferences and provide a shared decision-making structure for discussion at a clinic visit. For patients with rheumatoid arthritis (RA) who are considering methotrexate, we have developed a web-based patient decision aid called the ANSWER (Animated, Self-serve, Web-based Research Tool). This study aimed to: 1) assess the usability of the ANSWER prototype; 2) identify strengths and limitations of the ANSWER from the patient’s perspective. Methods The ANSWER prototype consisted of: 1) six animated patient stories and narrated information on the evidence of methotrexate for RA; 2) interactive questionnaires to clarify patients’ treatment preferences. Eligible participants for the usability test were patients with RA who had been prescribed methotrexate. They were asked to verbalize their thoughts (i.e., think aloud) while using the ANSWER, and to complete the System Usability Scale (SUS) to assess overall usability (range = 0-100; higher = more user friendly). Participants were audiotaped and observed, and field notes were taken. The testing continued until no new modifiable issues were found. We used descriptive statistics to summarize participant characteristics and the SUS scores. Content analysis was used to identified usability issues and navigation problems. Results 15 patients participated in the usability testing. The majority were aged 50 or over and were university/college graduates (n = 8, 53.4%). On average they took 56 minutes (SD = 34.8) to complete the tool. The mean SUS score was 81.2 (SD = 13.5). Content analysis of audiotapes and field notes revealed four categories of modifiable usability issues: 1) information delivery (i.e., clarity of the information and presentation style); 2) navigation control (i.e., difficulties in recognizing and using the navigation control buttons); 3) layout (i.e., position of the videos, text, diagrams and navigation buttons); 4) aesthetic (i.e., the colour, look and feel of the online tool). Conclusions Although the SUS score indicated high usability before and after major modification, findings from the think-aloud sessions illustrated areas that required further refinement. Our results highlight the importance of formative evaluation in usability testing. PMID:24289731

  19. Usability Evaluation of Public Web Mapping Sites

    NASA Astrophysics Data System (ADS)

    Wang, C.

    2014-04-01

    Web mapping sites are interactive maps that are accessed via Webpages. With the rapid development of Internet and Geographic Information System (GIS) field, public web mapping sites are not foreign to people. Nowadays, people use these web mapping sites for various reasons, in that increasing maps and related map services of web mapping sites are freely available for end users. Thus, increased users of web mapping sites led to more usability studies. Usability Engineering (UE), for instance, is an approach for analyzing and improving the usability of websites through examining and evaluating an interface. In this research, UE method was employed to explore usability problems of four public web mapping sites, analyze the problems quantitatively and provide guidelines for future design based on the test results. Firstly, the development progress for usability studies were described, and simultaneously several usability evaluation methods such as Usability Engineering (UE), User-Centered Design (UCD) and Human-Computer Interaction (HCI) were generally introduced. Then the method and procedure of experiments for the usability test were presented in detail. In this usability evaluation experiment, four public web mapping sites (Google Maps, Bing maps, Mapquest, Yahoo Maps) were chosen as the testing websites. And 42 people, who having different GIS skills (test users or experts), gender (male or female), age and nationality, participated in this test to complete the several test tasks in different teams. The test comprised three parts: a pretest background information questionnaire, several test tasks for quantitative statistics and progress analysis, and a posttest questionnaire. The pretest and posttest questionnaires focused on gaining the verbal explanation of their actions qualitatively. And the design for test tasks targeted at gathering quantitative data for the errors and problems of the websites. Then, the results mainly from the test part were analyzed. The success rate from different public web mapping sites was calculated and compared, and displayed by the means of diagram. And the answers from questionnaires were also classified and organized in this part. Moreover, based on the analysis, this paper expands the discussion about the layout, map visualization, map tools, search logic and etc. Finally, this paper closed with some valuable guidelines and suggestions for the design of public web mapping sites. Also, limitations for this research stated in the end.

  20. Usability testing of ANSWER: a web-based methotrexate decision aid for patients with rheumatoid arthritis.

    PubMed

    Li, Linda C; Adam, Paul M; Townsend, Anne F; Lacaille, Diane; Yousefi, Charlene; Stacey, Dawn; Gromala, Diane; Shaw, Chris D; Tugwell, Peter; Backman, Catherine L

    2013-12-01

    Decision aids are evidence-based tools designed to inform people of the potential benefit and harm of treatment options, clarify their preferences and provide a shared decision-making structure for discussion at a clinic visit. For patients with rheumatoid arthritis (RA) who are considering methotrexate, we have developed a web-based patient decision aid called the ANSWER (Animated, Self-serve, Web-based Research Tool). This study aimed to: 1) assess the usability of the ANSWER prototype; 2) identify strengths and limitations of the ANSWER from the patient's perspective. The ANSWER prototype consisted of: 1) six animated patient stories and narrated information on the evidence of methotrexate for RA; 2) interactive questionnaires to clarify patients' treatment preferences. Eligible participants for the usability test were patients with RA who had been prescribed methotrexate. They were asked to verbalize their thoughts (i.e., think aloud) while using the ANSWER, and to complete the System Usability Scale (SUS) to assess overall usability (range = 0-100; higher = more user friendly). Participants were audiotaped and observed, and field notes were taken. The testing continued until no new modifiable issues were found. We used descriptive statistics to summarize participant characteristics and the SUS scores. Content analysis was used to identified usability issues and navigation problems. 15 patients participated in the usability testing. The majority were aged 50 or over and were university/college graduates (n = 8, 53.4%). On average they took 56 minutes (SD = 34.8) to complete the tool. The mean SUS score was 81.2 (SD = 13.5). Content analysis of audiotapes and field notes revealed four categories of modifiable usability issues: 1) information delivery (i.e., clarity of the information and presentation style); 2) navigation control (i.e., difficulties in recognizing and using the navigation control buttons); 3) layout (i.e., position of the videos, text, diagrams and navigation buttons); 4) aesthetic (i.e., the colour, look and feel of the online tool). Although the SUS score indicated high usability before and after major modification, findings from the think-aloud sessions illustrated areas that required further refinement. Our results highlight the importance of formative evaluation in usability testing.

  1. CD-ROM and Metering--An Overview.

    ERIC Educational Resources Information Center

    Shear, Victor

    1992-01-01

    Discusses the need for security and metering features for CD-ROM products. Topics covered include user productivity issues, pricing problems, integrated information resources, advantages of CD-ROM distribution systems, unauthorized use, content encryption, and multiple simultaneous meters. (MES)

  2. Navigation in the electronic health record: A review of the safety and usability literature.

    PubMed

    Roman, Lisette C; Ancker, Jessica S; Johnson, Stephen B; Senathirajah, Yalini

    2017-03-01

    Inefficient navigation in electronic health records has been shown to increase users' cognitive load, which may increase potential for errors, reduce efficiency, and increase fatigue. However, navigation has received insufficient recognition and attention in the electronic health record (EHR) literature as an independent construct and contributor to overall usability. Our aims in this literature review were to (1) assess the prevalence of navigation-related topics within the EHR usability and safety research literature, (2) categorize types of navigation actions within the EHR, (3) capture relationships between these navigation actions and usability principles, and (4) collect terms and concepts related to EHR navigation. Our goal was to improve access to navigation-related research in usability. We applied scoping literature review search methods with the assistance of a reference librarian to identify articles published since 1996 that reported evaluation of the usability or safety of an EHR user interface via user test, analytic methods, or inspection methods. The 4336 references collected from MEDLINE, EMBASE, Engineering Village, and expert referrals were de-duplicated and screened for relevance, and navigation-related concepts were abstracted from the 21 articles eligible for review using a standard abstraction form. Of the 21 eligible articles, 20 (95%) mentioned navigation in results and discussion of usability evaluations. Navigation between pages of the EHR was the more frequently documented type of navigation (86%) compared to navigation within a single page (14%). Navigation actions (e.g., scrolling through a medication list) were frequently linked to specific usability heuristic violations, among which flexibility and efficiency of use, recognition rather than recall, and error prevention were most common. Discussion of navigation was prevalent in results across all types of evaluation methods among the articles reviewed. Navigating between multiple screens was frequently identified as a usability barrier. The lack of standard terminology created some challenges to identifying and comparing articles. We observed that usability researchers are frequently capturing navigation-related issues even in articles that did not explicitly state navigation as a focus. Capturing and synthesizing the literature on navigation is challenging because of the lack of uniform vocabulary. Navigation is a potential target for normative recommendations for improved interaction design for safer systems. Future research in this domain, including development of normative recommendations for usability design and evaluation, will be facilitated by development of a standard terminology for describing EHR navigation. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. A Wearable Sensor-Based Exercise Biofeedback System: Mixed Methods Evaluation of Formulift

    PubMed Central

    Slevin, Patrick; Ward, Tomas; Caulfield, Brian

    2018-01-01

    Background Formulift is a newly developed mobile health (mHealth) app that connects to a single inertial measurement unit (IMU) worn on the left thigh. The IMU captures users’ movements as they exercise, and the app analyzes the data to count repetitions in real time and classify users’ exercise technique. The app also offers feedback and guidance to users on exercising safely and effectively. Objective The aim of this study was to assess the Formulift system with three different and realistic types of potential users (beginner gym-goers, experienced gym-goers, and qualified strength and conditioning [S&C] coaches) under a number of categories: (1) usability, (2) functionality, (3) the perceived impact of the system, and (4) the subjective quality of the system. It was also desired to discover suggestions for future improvements to the system. Methods A total of 15 healthy volunteers participated (12 males; 3 females; age: 23.8 years [SD 1.80]; height: 1.79 m [SD 0.07], body mass: 78.4 kg [SD 9.6]). Five participants were beginner gym-goers, 5 were experienced gym-goers, and 5 were qualified and practicing S&C coaches. IMU data were first collected from each participant to create individualized exercise classifiers for them. They then completed a number of nonexercise-related tasks with the app. Following this, a workout was completed using the system, involving squats, deadlifts, lunges, and single-leg squats. Participants were then interviewed about their user experience and completed the System Usability Scale (SUS) and the user version of the Mobile Application Rating Scale (uMARS). Thematic analysis was completed on all interview transcripts, and survey results were analyzed. Results Qualitative and quantitative analysis found the system has “good” to “excellent” usability. The system achieved a mean (SD) SUS usability score of 79.2 (8.8). Functionality was also deemed to be good, with many users reporting positively on the systems repetition counting, technique classification, and feedback. A number of bugs were found, and other suggested changes to the system were also made. The overall subjective quality of the app was good, with a median star rating of 4 out of 5 (interquartile range, IQR: 3-5). Participants also reported that the system would aid their technique, provide motivation, reassure them, and help them avoid injury. Conclusions This study demonstrated an overall positive evaluation of Formulift in the categories of usability, functionality, perceived impact, and subjective quality. Users also suggested a number of changes for future iterations of the system. These findings are the first of their kind and show great promise for wearable sensor-based exercise biofeedback systems. PMID:29386171

  4. In Situ Soil Venting - Full Scale Test, Hill AFB, Guidance Document. Volume 2

    DTIC Science & Technology

    1991-08-01

    oxidizer. Another system was connected to the existing air scrubber of a building (Reference 23). The self-contained unit reported by Rippberger...devices on the market for flow rate measurement. Some of the more common devices are orifice meters, venturi meters, rotameters, pitot tubes, hot-wire...Notes on how to size and construct orifice meters can be found in Reference 41. * Venturi Meter - A venturi meter works basically on the same

  5. Supporting cancer patients in illness management: usability evaluation of a mobile app.

    PubMed

    Mirkovic, Jelena; Kaufman, David R; Ruland, Cornelia M

    2014-08-13

    Mobile phones and tablets currently represent a significant presence in people's everyday lives. They enable access to different information and services independent of current place and time. Such widespread connectivity offers significant potential in different app areas including health care. Our goal was to evaluate the usability of the Connect Mobile app. The mobile app enables mobile access to the Connect system, an online system that supports cancer patients in managing health-related issues. Along with symptom management, the system promotes better patient-provider communication, collaboration, and shared decision making. The Connect Mobile app enables access to the Connect system over both mobile phones and tablets. The study consisted of usability tests of a high fidelity prototype with 7 cancer patients where the objectives were to identify existing design and functionality issues and to provide patients with a real look-and-feel of the mobile system. In addition, we conducted semistructured interviews to obtain participants' feedback about app usefulness, identify the need for new system features and design requirements, and measure the acceptance of the mobile app and its features within everyday health management. The study revealed a total of 27 design issues (13 for mobile apps and 14 for tablet apps), which were mapped to source events (ie, errors, requests for help, participants' concurrent feedback, and moderator observation). We also applied usability heuristics to identify violations of usability principles. The majority of violations were related to enabling ease of input, screen readability, and glanceability (15 issues), as well as supporting an appropriate match between systems and the real world (7 issues) and consistent mapping of system functions and interactions (4 issues). Feedback from participants also showed the cancer patients' requirements for support systems and how these needs are influenced by different context-related factors, such as type of access terminal (eg, desktop computer, tablet, mobile phone) and phases of illness. Based on the observed results, we proposed design and functionality recommendations that can be used for the development of mobile apps for cancer patients to support their health management process. Understanding and addressing users' requirements is one of the main prerequisites for developing useful and effective technology-based health interventions. The results of this study outline different user requirements related to the design of the mobile patient support app for cancer patients. The results will be used in the iterative development of the Connect Mobile app and can also inform other developers and researchers in development, integration, and evaluation of mobile health apps and services that support cancer patients in managing their health-related issues.

  6. Testing the Feasibility and Usability of a Novel Smartphone-Based Self-Management Support System for Dialysis Patients: A Pilot Study.

    PubMed

    Hayashi, Aki; Yamaguchi, Satoko; Waki, Kayo; Fujiu, Katsuhito; Hanafusa, Norio; Nishi, Takahiro; Tomita, Hyoe; Kobayashi, Haruka; Fujita, Hideo; Kadowaki, Takashi; Nangaku, Masaomi; Ohe, Kazuhiko

    2017-04-20

    Diet and fluid restrictions that need continuous self-management are among the most difficult aspects of dialysis treatment. Smartphone applications may be useful for supporting self-management. Our objective is to investigate the feasibility and usability of a novel smartphone-based self-management support system for dialysis patients. We developed the Self-Management and Recording System for Dialysis (SMART-D), which supports self-monitoring of three mortality-related factors that can be modified by lifestyle: interdialytic weight gain and predialysis serum potassium and phosphorus concentrations. Data is displayed graphically, with all data evaluated automatically to determine whether they achieve the values suggested by the Japanese Society for Dialysis Therapy guidelines. In a pilot study, 9 dialysis patients used SMART-D system for 2 weeks. A total of 7 of them completed questionnaires rating their assessment of SMART-D's usability and their satisfaction with the system. In addition, the Kidney Disease Quality of Life scale was compared before and after the study period. All 9 participants were able to use SMART-D with no major problems. Completion rates for body weight, pre- and postdialysis weight, and serum potassium and phosphorus concentrations were, respectively, 89% (SD 23), 95% (SD 7), and 78% (SD 44). Of the 7 participants who completed the usability survey, all were motivated by the sense of security derived from using the system, and 6 of the 7 (86%) reported that using SMART-D helped improve their lifestyle and self-management. Using SMART-D was feasible, and the system was well regarded by patients. Further study with larger scale cohorts and longer study and follow-up periods is needed to evaluate the effects of SMART-D on clinical outcomes and quality of life. ©Aki Hayashi, Satoko Yamaguchi, Kayo Waki, Katsuhito Fujiu, Norio Hanafusa, Takahiro Nishi, Hyoe Tomita, Haruka Kobayashi, Hideo Fujita, Takashi Kadowaki, Masaomi Nangaku, Kazuhiko Ohe. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 20.04.2017.

  7. Testing the Feasibility and Usability of a Novel Smartphone-Based Self-Management Support System for Dialysis Patients: A Pilot Study

    PubMed Central

    Fujiu, Katsuhito; Hanafusa, Norio; Nishi, Takahiro; Tomita, Hyoe; Kobayashi, Haruka; Fujita, Hideo; Kadowaki, Takashi; Nangaku, Masaomi; Ohe, Kazuhiko

    2017-01-01

    Background Diet and fluid restrictions that need continuous self-management are among the most difficult aspects of dialysis treatment. Smartphone applications may be useful for supporting self-management. Objective Our objective is to investigate the feasibility and usability of a novel smartphone-based self-management support system for dialysis patients. Methods We developed the Self-Management and Recording System for Dialysis (SMART-D), which supports self-monitoring of three mortality-related factors that can be modified by lifestyle: interdialytic weight gain and predialysis serum potassium and phosphorus concentrations. Data is displayed graphically, with all data evaluated automatically to determine whether they achieve the values suggested by the Japanese Society for Dialysis Therapy guidelines. In a pilot study, 9 dialysis patients used SMART-D system for 2 weeks. A total of 7 of them completed questionnaires rating their assessment of SMART-D’s usability and their satisfaction with the system. In addition, the Kidney Disease Quality of Life scale was compared before and after the study period. Results All 9 participants were able to use SMART-D with no major problems. Completion rates for body weight, pre- and postdialysis weight, and serum potassium and phosphorus concentrations were, respectively, 89% (SD 23), 95% (SD 7), and 78% (SD 44). Of the 7 participants who completed the usability survey, all were motivated by the sense of security derived from using the system, and 6 of the 7 (86%) reported that using SMART-D helped improve their lifestyle and self-management. Conclusions Using SMART-D was feasible, and the system was well regarded by patients. Further study with larger scale cohorts and longer study and follow-up periods is needed to evaluate the effects of SMART-D on clinical outcomes and quality of life. PMID:28428168

  8. A continuous usability evaluation of an electronic medication administration record application.

    PubMed

    Vicente Oliveros, Noelia; Gramage Caro, Teresa; Pérez Menéndez-Conde, Covadonga; Álvarez-Diaz, Ana María; Martín-Aragón Álvarez, Sagrario; Bermejo Vicedo, Teresa; Delgado Silveira, Eva

    2017-12-01

    The complexity of an electronic medication administration record (eMAR) has been underestimated by most designers in the past. Usability issues, such as poorly designed user application flow in eMAR, are therefore of vital importance, since they can have a negative impact on nursing activities and result in poor outcomes. The purpose of this study was to evaluate the usability of an eMAR application during its development. A usability evaluation was conducted during the development of the eMAR application. Two usability methods were used: a heuristic evaluation complemented by usability testing. Each eMAR application version provided by the vendor was evaluated by 2 hospital pharmacists, who applied the heuristic method. They reviewed the eMAR tasks, detected usability problems and their heuristic violations, and rated the severity of the usability problems. Usability testing was used to assess the final application version by observing how 3 nurses interacted with the application. Thirty-four versions were assessed before the eMAR application was considered usable. During the heuristic evaluation, the usability problems decreased from 46 unique usability problems in version 1 (V1) to 9 in version 34 (V34). In V1, usability problems were categorized into 154 heuristic violations, which decreased to 27 in V34. The average severity rating also decreased from major usability problem (2.96) to no problem (0.23). During usability testing, the 3 nurses did not encounter new usability problems. A thorough heuristic evaluation is a good method for obtaining a usable eMAR application. This evaluation points key areas for improvement and decreases usability problems and their severity. © 2017 John Wiley & Sons, Ltd.

  9. Developing an area-wide system for coordinated ramp meter control.

    DOT National Transportation Integrated Search

    2008-12-01

    Ramp metering has been broadly accepted and deployed as an effective countermeasure : against both recurrent and non-recurrent congestion on freeways. However, many current ramp : metering algorithms tend to improve only freeway travels using local d...

  10. Using qualitative studies to improve the usability of an EMR.

    PubMed

    Rose, Alan F; Schnipper, Jeffrey L; Park, Elyse R; Poon, Eric G; Li, Qi; Middleton, Blackford

    2005-02-01

    The adoption of electronic medical records (EMRs) and user satisfaction are closely associated with the system's usability. To improve the usability of a results management module of a widely deployed web-based EMR, we conducted two qualitative studies that included multiple focus group and field study sessions. Qualitative research can help focus attention on user tasks and goals and identify patterns of care that can be visualized through task modeling exercises. Findings from both studies raised issues with the amount and organization of information in the display, interference with workflow patterns of primary care physicians, and the availability of visual cues and feedback. We used the findings of these studies to recommend design changes to the user interface of the results management module.

  11. 14 CFR 121.305 - Flight and navigational equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... is required when a third attitude instrument system usable through flight attitudes of 360° of pitch... electrical generating system; (3) Operates independently of any other attitude indicating system; (4) Is...

  12. 77 FR 38342 - Privacy Act of 1974; System of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-27

    ... to adding postage to postage meters. III. Description of Changes to Systems of Records The Postal... Management Records USPS 300.000 SYSTEM NAME: Finance Records USPS 400.000 SYSTEM NAME: Supplier and Tenant...: Postage Meter and PC Postage Customer Data and Transaction Records Accordingly, for the reasons stated...

  13. Examining Older Adults’ Perceptions of Usability and Acceptability of Remote Monitoring Systems to Manage Chronic Heart Failure

    PubMed Central

    Evangelista, Lorraine S.; Moser, Debra K.; Lee, Jung-Ah; Moore, Alison A.; Ghasemzadeh, Hassan; Sarrafzadeh, Majid; Mangione, Carol M.

    2015-01-01

    Objective: This study was conducted to evaluate the feasibility, usability, and acceptability of using remote monitoring systems (RMS) in monitoring health status (e.g., vital signs, symptom distress) in older adults (≥55) with chronic heart failure (HF). Method: Twenty-one patients (52.4% women, mean age 73.1 ± 9.3) were trained to measure and transmit health data with an RMS. Data transmissions were tracked for 12 weeks. Results: All participants initiated use of RMS within 1 week; 71%, 14%, and 14% of patients transmitted daily health data 100%, ≥75%, and <75% of the time, respectively, for 12 weeks. Overall usability and acceptability of the RMS were 4.08 ± 0.634 and 4.10 ± 0.563, respectively (when scored on a range of 1-5, where 1 = strongly disagree and 5 = strongly agree). Discussion: Findings show that an RMS-based intervention can be successfully implemented in a group of older patients with chronic HF. PMID:28138479

  14. Visualization of usability and functionality of a professional website through web-mining.

    PubMed

    Jones, Josette F; Mahoui, Malika; Gopa, Venkata Devi Pragna

    2007-10-11

    Functional interface design requires understanding of the information system structure and the user. Web logs record user interactions with the interface, and thus provide some insight into user search behavior and efficiency of the search process. The present study uses a data-mining approach with techniques such as association rules, clustering and classification, to visualize the usability and functionality of a digital library through in depth analyses of web logs.

  15. Cancer-meter: measure and cure.

    PubMed

    Kashyap, Sunil Kumar; Sharma, Birendra Kumar; Banerjee, Amitabh

    2017-05-01

    This paper presents a theory and system on "Cancer-Meter'. This idea came through the statement that "cancer is curable if it is measurable". The Cancer-Meter proves that it is possible. This paper proposes the cancer-meter in two ways, theoretical and electronically, as per the measurement and treatment. By the mathematics, first part is defined but the second part is based on computer programming, electrical and electronics. Thus, the cancer-meter is a programmed-electrical-electronic device which measures and cures the cancer both.

  16. TRL Assessment of Solar Sail Technology Development Following the 20-Meter System Ground Demonstrator Hardware Testing

    NASA Technical Reports Server (NTRS)

    Young, Roy M.; Montgomery, Edward E.; Montgomery, Sandy; Adams, Charles L.

    2007-01-01

    The NASA In-Space Propulsion Technology (ISPT) Projects Office has been sponsoring 2 separate, independent system design and development hardware demonstration activities during 2002-2005. ATK Space Systems of Goleta, CA was the prime contractor for one development team and L'Garde, Inc. of Tustin, CA was the prime contractor for the other development team. The goal of these activities was to advance the technology readiness level (TRL) of solar sail propulsion from 3 towards 6 by the year 2006. Component and subsystem fabrication and testing were completed successfully, including the ground deployment of 10-meter and 20-meter ground demonstration hardware systems under vacuum conditions. The deployment and structural testing of the 20-meter solar sail systems was conducted in the 30 meter diameter Space Power Facility thermal-vacuum chamber at NASA Glenn Plum Brook in April though August, 2005. This paper will present the results of the TRL assessment following the solar sail technology development activities associated with the design, development, analysis and testing of the 20-meter system ground demonstrators. Descriptions of the system designs for both the ATK and L'Garde systems will be presented. Changes, additions and evolution of the system designs will be highlighted. A description of the modeling and analyses activities performed by both teams, as well as testing conducted to raise the TRL of solar sail technology will be presented. A summary of the results of model correlation activities will be presented. Finally, technology gaps identified during the assessment and gap closure plans will be presented, along with "lessons learned", subsequent planning activities and validation flight opportunities for solar sail propulsion technology.

  17. Accuracy of acoustic velocity metering systems for measurement of low velocity in open channels

    USGS Publications Warehouse

    Laenen, Antonius; Curtis, R. E.

    1989-01-01

    Acoustic velocity meter (AVM) accuracy depends on equipment limitations, the accuracy of acoustic-path length and angle determination, and the stability of the mean velocity to acoustic-path velocity relation. Equipment limitations depend on path length and angle, transducer frequency, timing oscillator frequency, and signal-detection scheme. Typically, the velocity error from this source is about +or-1 to +or-10 mms/sec. Error in acoustic-path angle or length will result in a proportional measurement bias. Typically, an angle error of one degree will result in a velocity error of 2%, and a path-length error of one meter in 100 meter will result in an error of 1%. Ray bending (signal refraction) depends on path length and density gradients present in the stream. Any deviation from a straight acoustic path between transducer will change the unique relation between path velocity and mean velocity. These deviations will then introduce error in the mean velocity computation. Typically, for a 200-meter path length, the resultant error is less than one percent, but for a 1,000 meter path length, the error can be greater than 10%. Recent laboratory and field tests have substantiated assumptions of equipment limitations. Tow-tank tests of an AVM system with a 4.69-meter path length yielded an average standard deviation error of 9.3 mms/sec, and the field tests of an AVM system with a 20.5-meter path length yielded an average standard deviation error of a 4 mms/sec. (USGS)

  18. Summary of extensometric measurements in El Paso, Texas

    USGS Publications Warehouse

    Heywood, Charles E.

    2003-01-01

    Two counter-weighted-pipe borehole extensometers were installed on the left bank of the Rio Grande between El Paso, Texas, and Ciudad Juarez, Chihuahua, Mexico, in 1992. A shallow extensometer measures vertical compaction in the 6- to 100-meter aquifer-system depth interval. A deep extensometer measures vertical compaction in the 6- to 305-meter aquifer-system depth interval. Both extensometers are referenced to the same surface datum, which allows time-series differencing to determine vertical compaction in the depth interval between 100 and 305 meters. From April 2, 1993, through June 13, 2002, 1.6 centimeters of compaction occurred in the 6-to 305-m depth interval. Until February 1999, most aquifer-system compaction occurred in the deeper aquifer-system interval between 100 and 305 meters, from which ground water was extracted. After that time, compaction in the shallow interval from 6 to 100 meters was predominant and attained a maximum of 7.6 millimeters by June 13, 2002. Minor residual compaction is expected to continue; continued maintenance of the El Paso extensometers would document this process.

  19. Usability of American Nurses Association State Web Sites: A Follow-up Evaluation.

    PubMed

    Koch, Gina; Wakefield, Bonnie J; Alexander, Gregory L; Wilson, Melissa A; Becker, Colleen

    2016-05-01

    The American Nurses Association supports professional nurses through Web sites administered by state nursing associations, providing important information for current and potential members. Optimal usability of these Web sites is critical for nurses to obtain the information they seek. Heuristic evaluations are general criteria used to evaluate the usability of technology such as Web sites. A study published in 2014, using heuristic criteria from Nielsen's 10 principles and Health on The Web, evaluated 27 state nursing Web sites to identify usability concerns that could prevent nurses from obtaining accurate information regarding state nursing practice. The purpose of this study is to conduct a second heuristic evaluation to assess for changes in a subset of 12 Web sites. The analysis comparing the evaluation from 2012 to 2014 found that mean scores increased and variance decreased; however, no statistically significant difference was found between the two studies. Scores increased in 2014 for "help users to diagnose, and recover from errors," "match between the system and real world," and "consistency and standards." Scores decreased due to absence of mission statements and identification of intended audience. Ideally, Web site designers will use the feedback from this study and make changes that improve their usability to provide information to nurses.

  20. Development of an integrated utilities billing management system for the Navy Public Works Center San Diego, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monsabert, S. de; Lemmer, H.; Dinwiddie, D.

    1995-10-01

    In the past, most buildings, structures, and ship visits were not metered, and flat estimates were calculated based on various estimating techniques. The decomposition process was further complicated by the fact that many of the meters monitor consumption values only and do not provide demand or time of use data. This method of billing provides no incentives to the PWC customers to implement energy conservation programs, including load shedding, Energy Monitoring and Control Systems (EMCS), building shell improvements, low flow toilets and shower heads, efficient lighting systems, or other energy savings alternatives. Similarly, the method had no means of adjustmentmore » for seasonal or climatic variations outside of the norm. As an alternative to flat estimates, the Customized Utility Billing Integrated Control (CUBIC) system and the Graphical Data Input System (GDIS) were developed to better manage the data to the major claimant area users based on utilities usage factors, building size, weather data, and hours of operation. GDIS is a graphical database that assists PWC engineers in the development and maintenance of single-line utility diagrams of the facilities and meters. It functions as a drawing associate system and is written in AutoLISP for AutoCAD version 12. GDIS interprets the drawings and provides the facility-to-meter and meter-to-meter hierarchy data that are used by the CUBIC to allocate the billings. This paper reviews the design, development and implementation aspects of CUBIC/GDIS and discusses the benefits of this improved utilities management system.« less

  1. Facilitating Secure Sharing of Personal Health Data in the Cloud.

    PubMed

    Thilakanathan, Danan; Calvo, Rafael A; Chen, Shiping; Nepal, Surya; Glozier, Nick

    2016-05-27

    Internet-based applications are providing new ways of promoting health and reducing the cost of care. Although data can be kept encrypted in servers, the user does not have the ability to decide whom the data are shared with. Technically this is linked to the problem of who owns the data encryption keys required to decrypt the data. Currently, cloud service providers, rather than users, have full rights to the key. In practical terms this makes the users lose full control over their data. Trust and uptake of these applications can be increased by allowing patients to feel in control of their data, generally stored in cloud-based services. This paper addresses this security challenge by providing the user a way of controlling encryption keys independently of the cloud service provider. We provide a secure and usable system that enables a patient to share health information with doctors and specialists. We contribute a secure protocol for patients to share their data with doctors and others on the cloud while keeping complete ownership. We developed a simple, stereotypical health application and carried out security tests, performance tests, and usability tests with both students and doctors (N=15). We developed the health application as an app for Android mobile phones. We carried out the usability tests on potential participants and medical professionals. Of 20 participants, 14 (70%) either agreed or strongly agreed that they felt safer using our system. Using mixed methods, we show that participants agreed that privacy and security of health data are important and that our system addresses these issues. We presented a security protocol that enables patients to securely share their eHealth data with doctors and nurses and developed a secure and usable system that enables patients to share mental health information with doctors.

  2. From expert-derived user needs to user-perceived ease of use and usefulness: a two-phase mixed-methods evaluation framework.

    PubMed

    Boland, Mary Regina; Rusanov, Alexander; So, Yat; Lopez-Jimenez, Carlos; Busacca, Linda; Steinman, Richard C; Bakken, Suzanne; Bigger, J Thomas; Weng, Chunhua

    2014-12-01

    Underspecified user needs and frequent lack of a gold standard reference are typical barriers to technology evaluation. To address this problem, this paper presents a two-phase evaluation framework involving usability experts (phase 1) and end-users (phase 2). In phase 1, a cross-system functionality alignment between expert-derived user needs and system functions was performed to inform the choice of "the best available" comparison system to enable a cognitive walkthrough in phase 1 and a comparative effectiveness evaluation in phase 2. During phase 2, five quantitative and qualitative evaluation methods are mixed to assess usability: time-motion analysis, software log, questionnaires - System Usability Scale and the Unified Theory of Acceptance of Use of Technology, think-aloud protocols, and unstructured interviews. Each method contributes data for a unique measure (e.g., time motion analysis contributes task-completion-time; software log contributes action transition frequency). The measures are triangulated to yield complementary insights regarding user-perceived ease-of-use, functionality integration, anxiety during use, and workflow impact. To illustrate its use, we applied this framework in a formative evaluation of a software called Integrated Model for Patient Care and Clinical Trials (IMPACT). We conclude that this mixed-methods evaluation framework enables an integrated assessment of user needs satisfaction and user-perceived usefulness and usability of a novel design. This evaluation framework effectively bridges the gap between co-evolving user needs and technology designs during iterative prototyping and is particularly useful when it is difficult for users to articulate their needs for technology support due to the lack of a baseline. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments.

    PubMed

    Geerse, Daphne J; Coolen, Bert H; Roerdink, Melvyn

    2015-01-01

    Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point's time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point's time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters' walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman's bias and limits of agreement. Body point's time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point's time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner.

  4. Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments

    PubMed Central

    Geerse, Daphne J.; Coolen, Bert H.; Roerdink, Melvyn

    2015-01-01

    Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect’s 3D body point’s time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point’s time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point’s time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters’ walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman’s bias and limits of agreement. Body point’s time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point’s time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner. PMID:26461498

  5. The usability of ventilators: a comparative evaluation of use safety and user experience.

    PubMed

    Morita, Plinio P; Weinstein, Peter B; Flewwelling, Christopher J; Bañez, Carleene A; Chiu, Tabitha A; Iannuzzi, Mario; Patel, Aastha H; Shier, Ashleigh P; Cafazzo, Joseph A

    2016-08-20

    The design complexity of critical care ventilators (CCVs) can lead to use errors and patient harm. In this study, we present the results of a comparison of four CCVs from market leaders, using a rigorous methodology for the evaluation of use safety and user experience of medical devices. We carried out a comparative usability study of four CCVs: Hamilton G5, Puritan Bennett 980, Maquet SERVO-U, and Dräger Evita V500. Forty-eight critical care respiratory therapists participated in this fully counterbalanced, repeated measures study. Participants completed seven clinical scenarios composed of 16 tasks on each ventilator. Use safety was measured by percentage of tasks with use errors or close calls (UE/CCs). User experience was measured by system usability and workload metrics, using the Post-Study System Usability Questionnaire (PSSUQ) and the National Aeronautics and Space Administration Task Load Index (NASA-TLX). Nine of 18 post hoc contrasts between pairs of ventilators were significant after Bonferroni correction, with effect sizes between 0.4 and 1.09 (Cohen's d). There were significantly fewer UE/CCs with SERVO-U when compared to G5 (p = 0.044) and V500 (p = 0.020). Participants reported higher system usability for G5 when compared to PB980 (p = 0.035) and higher system usability for SERVO-U when compared to G5 (p < 0.001), PB980 (p < 0.001), and V500 (p < 0.001). Participants reported lower workload for G5 when compared to PB980 (p < 0.001) and lower workload for SERVO-U when compared to PB980 (p < 0.001) and V500 (p < 0.001). G5 scored better on two of nine possible comparisons; SERVO-U scored better on seven of nine possible comparisons. Aspects influencing participants' performance and perception include the low sensitivity of G5's touchscreen and the positive effect from the quality of SERVO-U's user interface design. This study provides empirical evidence of how four ventilators from market leaders compare and highlights the importance of medical technology design. Within the boundaries of this study, we can infer that SERVO-U demonstrated the highest levels of use safety and user experience, followed by G5. Based on qualitative data, differences in outcomes could be explained by interaction design, quality of hardware components used in manufacturing, and influence of consumer product technology on users' expectations.

  6. 49 CFR 192.1015 - What must a master meter or small liquefied petroleum gas (LPG) operator do to implement this...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false What must a master meter or small liquefied... a master meter or small liquefied petroleum gas (LPG) operator do to implement this subpart? (a) General. No later than August 2, 2011 the operator of a master meter system or a small LPG operator must...

  7. 49 CFR 192.1015 - What must a master meter or small liquefied petroleum gas (LPG) operator do to implement this...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false What must a master meter or small liquefied... a master meter or small liquefied petroleum gas (LPG) operator do to implement this subpart? (a) General. No later than August 2, 2011 the operator of a master meter system or a small LPG operator must...

  8. 49 CFR 192.1015 - What must a master meter or small liquefied petroleum gas (LPG) operator do to implement this...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false What must a master meter or small liquefied... a master meter or small liquefied petroleum gas (LPG) operator do to implement this subpart? (a) General. No later than August 2, 2011 the operator of a master meter system or a small LPG operator must...

  9. Momentum harvesting techniques for solar system travel

    NASA Technical Reports Server (NTRS)

    Willoughby, Alan J.

    1991-01-01

    Astronomers are lately estimating there are 400,000 earth visiting asteroids larger than 100 meters in diameter. These asteroids are uniquely accessible sources of building materials, propellants, oxygen, water, and minerals. They also constitute a huge momentum reserve, potentially usable for travel throughout the solar system. To use this momentum, these stealthy objects must be tracked and the ability to extract the desired momentum obtained. Momentum harvesting by momentum transfer from asteroid to spacecraft, and by using the momentum of the extraterrestrial material to help deliver itself to its destination is discussed. The purpose is neither to quantify nor justify the momentum exchange processes, but to stimulate collective imaginations with some intriguing possibilities which emerge when momentum as well as material is considered. A net and tether concept is the suggested means of asteroid capture, the basic momentum exchange process. The energy damping characteristics of the tether determines the velocity mismatch that can be tolerated, and hence the amount of momentum that can be harvested per capture. As the tether plays out of its reel, drag on the tether steadily accelerates the spacecraft and dilutes, in time, the would-be collision. A variety of concepts for riding and using asteroids after capture are introduced. The hitchhiker uses momentum transfer only. The beachcomber, the caveman, the swinger, the prospector, and the rock wrecker also take advantage of raw asteroid materials. The chemist and the hijacker go further, they process the asteroid into propellants. Or, an asteroid railway system could be constructed with each hijacked asteroid becoming a scheduled train. Travelers could board this space railway system assured that water, oxygen propellants, and shielding await them. Austere space travel could give way to comforts, with a speed and economy impossible without nature's gift of earth visiting asteroids.

  10. System for photometric calibration of optoelectronic imaging devices especially streak cameras

    DOEpatents

    Boni, Robert; Jaanimagi, Paul

    2003-11-04

    A system for the photometric calibration of streak cameras and similar imaging devices provides a precise knowledge of the camera's flat-field response as well as a mapping of the geometric distortions. The system provides the flat-field response, representing the spatial variations in the sensitivity of the recorded output, with a signal-to-noise ratio (SNR) greater than can be achieved in a single submicrosecond streak record. The measurement of the flat-field response is carried out by illuminating the input slit of the streak camera with a signal that is uniform in space and constant in time. This signal is generated by passing a continuous wave source through an optical homogenizer made up of a light pipe or pipes in which the illumination typically makes several bounces before exiting as a spatially uniform source field. The rectangular cross-section of the homogenizer is matched to the usable photocathode area of the streak tube. The flat-field data set is obtained by using a slow streak ramp that may have a period from one millisecond (ms) to ten seconds (s), but may be nominally one second in duration. The system also provides a mapping of the geometric distortions, by spatially and temporarily modulating the output of the homogenizer and obtaining a data set using the slow streak ramps. All data sets are acquired using a CCD camera and stored on a computer, which is used to calculate all relevant corrections to the signal data sets. The signal and flat-field data sets are both corrected for geometric distortions prior to applying the flat-field correction. Absolute photometric calibration is obtained by measuring the output fluence of the homogenizer with a "standard-traceable" meter and relating that to the CCD pixel values for a self-corrected flat-field data set.

  11. Active bypass flow control for a seal in a gas turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebert, Todd A.; Kimmel, Keith D.

    An active bypass flow control system for controlling bypass compressed air based upon leakage flow of compressed air flowing past an outer balance seal between a stator and rotor of a first stage of a gas turbine in a gas turbine engine is disclosed. The active bypass flow control system is an adjustable system in which one or more metering devices may be used to control the flow of bypass compressed air as the flow of compressed air past the outer balance seal changes over time as the outer balance seal between the rim cavity and the cooling cavity wearsmore » In at least one embodiment, the metering device may include an annular ring having at least one metering orifice extending therethrough, whereby alignment of the metering orifice with the outlet may be adjustable to change a cross-sectional area of an opening of aligned portions of the outlet and the metering orifice.« less

  12. Accuracy and precision of four value-added blood glucose meters: the Abbott Optium, the DDI Prodigy, the HDI True Track, and the HypoGuard Assure Pro.

    PubMed

    Sheffield, Catherine A; Kane, Michael P; Bakst, Gary; Busch, Robert S; Abelseth, Jill M; Hamilton, Robert A

    2009-09-01

    This study compared the accuracy and precision of four value-added glucose meters. Finger stick glucose measurements in diabetes patients were performed using the Abbott Diabetes Care (Alameda, CA) Optium, Diagnostic Devices, Inc. (Miami, FL) DDI Prodigy, Home Diagnostics, Inc. (Fort Lauderdale, FL) HDI True Track Smart System, and Arkray, USA (Minneapolis, MN) HypoGuard Assure Pro. Finger glucose measurements were compared with laboratory reference results. Accuracy was assessed by a Clarke error grid analysis (EGA), a Parkes EGA, and within 5%, 10%, 15%, and 20% of the laboratory value criteria (chi2 analysis). Meter precision was determined by calculating absolute mean differences in glucose values between duplicate samples (Kruskal-Wallis test). Finger sticks were obtained from 125 diabetes patients, of which 90.4% were Caucasian, 51.2% were female, 83.2% had type 2 diabetes, and average age of 59 years (SD 14 years). Mean venipuncture blood glucose was 151 mg/dL (SD +/-65 mg/dL; range, 58-474 mg/dL). Clinical accuracy by Clarke EGA was demonstrated in 94% of Optium, 82% of Prodigy, 61% of True Track, and 77% of the Assure Pro samples (P < 0.05 for Optium and True Track compared to all others). By Parkes EGA, the True Track was significantly less accurate than the other meters. Within 5% accuracy was achieved in 34%, 24%, 29%, and 13%, respectively (P < 0.05 for Optium, Prodigy, and Assure Pro compared to True Track). Within 10% accuracy was significantly greater for the Optium, Prodigy, and Assure Pro compared to True Track. Significantly more Optium results demonstrated within 15% and 20% accuracy compared to the other meter systems. The HDI True Track was significantly less precise than the other meter systems. The Abbott Optium was significantly more accurate than the other meter systems, whereas the HDI True Track was significantly less accurate and less precise compared to the other meter systems.

  13. 40 CFR 90.420 - CVS concept of exhaust gas sampling system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...

  14. 40 CFR 90.420 - CVS concept of exhaust gas sampling system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...

  15. 40 CFR 90.420 - CVS concept of exhaust gas sampling system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...

  16. 40 CFR 90.420 - CVS concept of exhaust gas sampling system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...

  17. 40 CFR 90.420 - CVS concept of exhaust gas sampling system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...

  18. Human interaction with wearable computer systems: a look at glasses-mounted displays

    NASA Astrophysics Data System (ADS)

    Revels, Allen R.; Quill, Laurie L.; Kancler, David E.; Masquelier, Barbara L.

    1998-09-01

    With the advancement of technology and the information explosion, integration of the two into performance aiding systems can have a significant impact on operational and maintenance environments. The Department of Defense and commercial industry have made great strides in digitizing and automating technical manuals and data to be presented on performance aiding systems. These performance aides are computerized interactive systems that provide procedures on how to operate and maintain fielded systems. The idea is to provide the end-user a system which is compatible with their work environment. The purpose of this paper is to show, historically, the progression of wearable computer aiding systems for maintenance environments, and then highlight the work accomplished in the design and development of glasses- mounted displays (GMD). The paper reviews work performed over the last seven years, then highlights, through review of a usability study, the advances made with GMDs. The use of portable computing systems, such as laptop and notebook, computers, does not necessarily increase the accessibility of the displayed information while accomplishing a given task in a hands-busy, mobile work environment. The use of a GMD increases accessibility of the information by placing it in eye sight of the user without obstructing the surrounding environment. Although the potential utility for this type of display is great, hardware and human integration must be refined. Results from the usability study show the usefulness and usability of the GMD in a mobile, hands-free environment.

  19. A Robot-Based Tool for Physical and Cognitive Rehabilitation of Elderly People Using Biofeedback

    PubMed Central

    Lopez-Samaniego, Leire; Garcia-Zapirain, Begonya

    2016-01-01

    This publication presents a complete description of a technological solution system for the physical and cognitive rehabilitation of elderly people through a biofeedback system, which is combined with a Lego robot. The technology used was the iOS’s (iPhone Operating System) Objective-C programming language and its XCode programming environment; and SQLite in order to create the database. The biofeedback system is implemented by the use of two biosensors which are, in fact, a Microsoft band 2 in order to register the user’s heart rate and a MYO sensor to detect the user’s arm movement. Finally, the system was tested with seven elderly people from La Santa y Real Casa de la Misericordia nursing home in Bilbao. The statistical assessment has shown that the users are satisfied with the usability of the system, with a mean score of 79.29 on the System Usability Scale (SUS) questionnaire. PMID:27886146

  20. Slit-lamp photography made easy by a spot metering system.

    PubMed Central

    Khaw, P T; Elkington, A R

    1988-01-01

    The use of a standard 35 mm camera with a spot metering system to take slit-lamp photographs is described. This system is mounted on a standard Haag-Streit slit-lamp and can be used with good results even by inexperienced operators. Images PMID:3390424

  1. Real-time adaptive ramp metering : phase I, MILOS proof of concept (multi-objective, integrated, large-scale, optimized system).

    DOT National Transportation Integrated Search

    2006-12-01

    Over the last several years, researchers at the University of Arizonas ATLAS Center have developed an adaptive ramp : metering system referred to as MILOS (Multi-Objective, Integrated, Large-Scale, Optimized System). The goal of this project : is ...

  2. Weak-value amplification as an optimal metrological protocol

    NASA Astrophysics Data System (ADS)

    Alves, G. Bié; Escher, B. M.; de Matos Filho, R. L.; Zagury, N.; Davidovich, L.

    2015-06-01

    The implementation of weak-value amplification requires the pre- and postselection of states of a quantum system, followed by the observation of the response of the meter, which interacts weakly with the system. Data acquisition from the meter is conditioned to successful postselection events. Here we derive an optimal postselection procedure for estimating the coupling constant between system and meter and show that it leads both to weak-value amplification and to the saturation of the quantum Fisher information, under conditions fulfilled by all previously reported experiments on the amplification of weak signals. For most of the preselected states, full information on the coupling constant can be extracted from the meter data set alone, while for a small fraction of the space of preselected states, it must be obtained from the postselection statistics.

  3. Display system replacement baseline research report.

    DOT National Transportation Integrated Search

    2000-12-01

    This report provides baseline measurements on the Display System Replacement (DSR). These measurements followed six constructs: : safety, capacity, performance, workload, usability, and simulation fidelity. To collect these measurements, human factor...

  4. An object-oriented mobile health system with usability features.

    PubMed

    Escarfullet, Krystle; Moore, Cantera; Tucker, Shari; Wei, June

    2012-01-01

    Mobile health (m-health) comprises the concept of utilising mobile devices to carry out the task of viewing electronic medical records, reserving medical appointments with a patient's medical provider and electronically refilling prescriptions. This paper aims at developing a m-health system to improve usability from a user's perspective. Specifically, it first developed a m-health model by logically linking characteristics of the m-health system together based on information flows. Then, the system requirements were collected by using a developed questionnaire. These requirements were structured and further in-depth analysis was conducted by using an object-oriented approach based on unified modelling language, such as use-case, sequence and analysis class diagrams. This research will be beneficial to decision makers and developers in the mobile healthcare industry.

  5. Usability and Utility of a Mobile Application for Marksmanship Training

    DTIC Science & Technology

    2015-01-01

    Right of Canada, as represented by the Minister of National Defence, 2015 © Sa Majesté la Reine (en droit du Canada), telle que représentée par le...Empirical Evaluation of the System Usability Scale. International Journal of Human-Computer Interaction, 24(6), 574-594. BenMoussa, C. (2003). Workers on...Behavioral and Social Sciences. Jumisko-Pyykko, S., & Vainio, T. (2011). Framing the Context of Use for Mobile HCI. International Journal of Mobile

  6. Simplified Processing Method for Meter Data Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, Kimberly M.; Colotelo, Alison H. A.; Downs, Janelle L.

    2015-11-01

    Simple/Quick metered data processing method that can be used for Army Metered Data Management System (MDMS) and Logistics Innovation Agency data, but may also be useful for other large data sets. Intended for large data sets when analyst has little information about the buildings.

  7. Usability of a mobile electronic medical record prototype: a verbal protocol analysis.

    PubMed

    Wu, Robert C; Orr, M Scott; Chignell, Mark; Straus, Sharon E

    2008-06-01

    Point of care access to electronic medical records may provide clinicians with the information they want when they need it and may in turn improve patient safety. Yet providing an electronic medical record on handheld devices presents many usability challenges, and it is unclear whether clinicians will use them. An iterative design process for the development and evaluation of a prototype of a mobile electronic medical record was performed. Usability sessions were conducted in which physicians were asked to 'think aloud' while working through clinical scenarios using the prototype. Verbal protocol analysis, which consists of coding utterances, was conducted on the transcripts from the sessions and common themes were extracted. Usability sessions were held with five family physicians and four internists with varying levels of computer expertise. Physicians were able to use the device to complete 52 of 54 required tasks. Users commented that it was intuitive (9/9), would increase accessibility (5/9) but for them to use it, it would need the system to be fast and time-saving (5/9). Users had difficulty entering information (5/9) and reading the screen (4/9). In terms of functionality, users had concerns about completeness of information (6/9), details of ordering (5/9) and desired billing functionality (5/9) and integration with other systems (4/9). While physicians can use mobile electronic medical records in realistic scenarios, certain requirements likely need to be met including a fast system with easy data selection, easy data entry and improved display before widespread adoption occurs.

  8. Addressing security, collaboration, and usability with tactical edge mobile devices and strategic cloud-based systems

    NASA Astrophysics Data System (ADS)

    Graham, Christopher J.

    2012-05-01

    Success in the future battle space is increasingly dependent on rapid access to the right information. Faced with a shrinking budget, the Government has a mandate to improve intelligence productivity, quality, and reliability. To achieve increased ISR effectiveness, leverage of tactical edge mobile devices via integration with strategic cloud-based infrastructure is the single, most likely candidate area for dramatic near-term impact. This paper discusses security, collaboration, and usability components of this evolving space. These three paramount tenets outlined below, embody how mission information is exchanged securely, efficiently, with social media cooperativeness. Tenet 1: Complete security, privacy, and data integrity, must be ensured within the net-centric battle space. This paper discusses data security on a mobile device, data at rest on a cloud-based system, authorization and access control, and securing data transport between entities. Tenet 2: Lack of collaborative information sharing and content reliability jeopardizes mission objectives and limits the end user capability. This paper discusses cooperative pairing of mobile devices and cloud systems, enabling social media style interaction via tagging, meta-data refinement, and sharing of pertinent data. Tenet 3: Fielded mobile solutions must address usability and complexity. Simplicity is a powerful paradigm on mobile platforms, where complex applications are not utilized, and simple, yet powerful, applications flourish. This paper discusses strategies for ensuring mobile applications are streamlined and usable at the tactical edge through focused features sets, leveraging the power of the back-end cloud, minimization of differing HMI concepts, and directed end-user feedback.teInput=

  9. Electro-optical equivalent calibration technology for high-energy laser energy meters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wei, Ji Feng, E-mail: wjfcom2000@163.com; Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900; Graduate School of China Academy of Engineering Physics, Beijing 100088

    Electro-optical equivalent calibration with high calibration power and high equivalence is particularly well-suited to the calibration of high-energy laser energy meters. A large amount of energy is reserved during this process, however, which continues to radiate after power-off. This study measured the radiation efficiency of a halogen tungsten lamp during power-on and after power-off in order to calculate the total energy irradiated by a lamp until the high-energy laser energy meter reaches thermal equilibrium. A calibration system was designed based on the measurement results, and the calibration equivalence of the system was analyzed in detail. Results show that measurement precisionmore » is significantly affected by the absorption factor of the absorption chamber and by heat loss in the energy meter. Calibration precision is successfully improved by enhancing the equivalent power and reducing power-on time. The electro-optical equivalent calibration system, measurement uncertainty of which was evaluated as 2.4% (k = 2), was used to calibrate a graphite-cone-absorption-cavity absolute energy meter, yielding a calibration coefficient of 1.009 and measurement uncertainty of 3.5% (k = 2). A water-absorption-type high-energy laser energy meter with measurement uncertainty of 4.8% (k = 2) was considered the reference standard, and compared to the energy meter calibrated in this study, yielded a correction factor of 0.995 (standard deviation of 1.4%).« less

  10. Exploring the learnability and usability of a near field communication-based application for semantic enrichment in children with language disorders.

    PubMed

    Lorusso, Maria Luisa; Biffi, Emilia; Molteni, Massimo; Reni, Gianluigi

    2018-01-01

    Recently, a few software applications (apps) have been developed to enhance vocabulary and conceptual networks to address the needs of children with language impairments (LI), but there is no evidence about their impact and their usability in therapy contexts. Here, we try to fill this gap presenting a system aimed at improving the semantic competence and the structural knowledge of children with LI. The goal of the study is to evaluate learnability, usability, user satisfaction and quality of the interaction between the system and the children. The system consists of a tablet, hosting an app with educational and training purposes, equipped with a Near Field Communication (NFC) reader, used to interact with the user by means of objects. Fourteen preschool children with LI played with the device during one 45-minute speech therapy session. Reactions and feedbacks were recorded and rated. The system proved to be easy to understand and learn, as well as engaging and rewarding. The success of the device probably rests on the integration of smart technology and real, tangible objects. The device can be seen as a valuable aid to support and enhance communication abilities in children with LI as well as typically developing individuals.

  11. Evaluation of the functional performance and technical quality of an Electronic Documentation System of the Nursing Process.

    PubMed

    de Oliveira, Neurilene Batista; Peres, Heloisa Helena Ciqueto

    2015-01-01

    To evaluate the functional performance and the technical quality of the Electronic Documentation System of the Nursing Process of the Teaching Hospital of the University of São Paulo. exploratory-descriptive study. The Quality Model of regulatory standard 25010 and the Evaluation Process defined under regulatory standard 25040, both of the International Organization for Standardization/International Electrotechnical Commission. The quality characteristics evaluated were: functional suitability, reliability, usability, performance efficiency, compatibility, security, maintainability and portability. The sample was made up of 37 evaluators. in the evaluation of the specialists in information technology, only the characteristic of usability obtained a rate of positive responses of less than 70%. For the nurse lecturers, all the quality characteristics obtained a rate of positive responses of over 70%. The staff nurses of the medical and surgical clinics with experience in using the system) and staff nurses from other units of the hospital and from other health institutions (without experience in using the system) obtained rates of positive responses of more than 70% referent to the functional suitability, usability, and security. However, performance efficiency, reliability and compatibility all obtained rates below the parameter established. the software achieved rates of positive responses of over 70% for the majority of the quality characteristics evaluated.

  12. NASA Johnson Space Center Usability Testing and Analysis facility (UTAF) Overview

    NASA Technical Reports Server (NTRS)

    Whitmore, Mihriban; Holden, Kritina L.

    2005-01-01

    The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility performs research for NASA's HumanSystems Integration Program, under the HumanSystems Research and Technology Division. Specifically, the UTAF provides human factors support for space vehicles, including the International Space Station, the Space Shuttle, and the forthcoming Crew Exploration Vehicle. In addition, there are ongoing collaborative research efforts with external corporations and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes and requirements. This presentation will provide an overview of ongoing activities, and will address how the UTAF projects will evolve to meet new space initiatives.

  13. Usability issues concerning child restraint system harness design.

    PubMed

    Rudin-Brown, Christina M; Kumagai, Jason K; Angel, Harry A; Iwasa-Madge, Kim M; Noy, Y Ian

    2003-05-01

    A study was conducted to assess usability issues relating to child restraint system (CRS) harness design. Four convertible child restraint systems representing a wide variety of design features were used. Forty-two participants installed two child test dummies in both forward- and rear-facing configurations either inside or outside a test vehicle. Observer-scored checklists determined the degree to which each harness was installed correctly. Participant-scored questionnaires evaluated the 'ease-of-use' of various design features. While the percentage of correct installations exceeded 83% for all designs when installed in the forward-facing configuration, in the rear-facing position (that intended for children under 9-10 kg), there was a significant (between 65 and 89%) percentage of incorrect installations for all models. This finding is of particular interest and may be indicative of a more generalized problem with 'convertible' CRS designs when they are used in the rear-facing configuration. Furthermore, while certain design features were perceived by users as providing significantly better protection in the event of a collision, these also tended to be the features that were misused most often. The benefits and costs of various design features are discussed, and a method to test harness design usability is presented.

  14. Dynamic Tunnel Usability Study: Format Recommendations for Synthetic Vision System Primary Flight Displays

    NASA Technical Reports Server (NTRS)

    Arthur, Jarvis J., III; Prinzel, Lawrence J., III; Kramer, Lynda J.; Bailey, Randall E.

    2006-01-01

    A usability study evaluating dynamic tunnel concepts has been completed under the Aviation Safety and Security Program, Synthetic Vision Systems Project. The usability study was conducted in the Visual Imaging Simulator for Transport Aircraft Systems (VISTAS) III simulator in the form of questionnaires and pilot-in-the-loop simulation sessions. Twelve commercial pilots participated in the study to determine their preferences via paired comparisons and subjective rankings regarding the color, line thickness and sensitivity of the dynamic tunnel. The results of the study showed that color was not significant in pilot preference paired comparisons or in pilot rankings. Line thickness was significant for both pilot preference paired comparisons and in pilot rankings. The preferred line/halo thickness combination was a line width of 3 pixels and a halo of 4 pixels. Finally, pilots were asked their preference for the current dynamic tunnel compared to a less sensitive dynamic tunnel. The current dynamic tunnel constantly gives feedback to the pilot with regard to path error while the less sensitive tunnel only changes as the path error approaches the edges of the tunnel. The tunnel sensitivity comparison results were not statistically significant.

  15. Reduction of Burnout in Mental Health Care Providers Using the Provider Resilience Mobile Application.

    PubMed

    Wood, Amanda Ernst; Prins, Annabel; Bush, Nigel E; Hsia, Jennifer F; Bourn, Laura E; Earley, Michael D; Walser, Robyn D; Ruzek, Josef

    2017-05-01

    This pilot study examined the usability, acceptability, and effectiveness of a free Provider Resilience (PR) mobile application (app) designed by the National Center for Telehealth and Technology to reduce provider burnout. Outpatient mental health providers (N = 30) used the PR app for 1 month. Participants rated the PR app on the System Usability Scale with an overall score of 79.7, which is in the top quartile for usability. Results of paired sample t tests on the Professional Quality of Life Scale indicated significant decreases on the Burnout (t = 3.65, p < .001) and Compassion Fatigue (t = 4.54, p < .001) subscales. The Provider Resilience app shows promise in reducing burnout and compassion fatigue in mental health care providers.

  16. A personal health information toolkit for health intervention research.

    PubMed

    Kizakevich, Paul N; Eckhoff, Randall; Weger, Stacey; Weeks, Adam; Brown, Janice; Bryant, Stephanie; Bakalov, Vesselina; Zhang, Yuying; Lyden, Jennifer; Spira, James

    2014-01-01

    With the emergence of mobile health (mHealth) apps, there is a growing demand for better tools for developing and evaluating mobile health interventions. Recently we developed the Personal Health Intervention Toolkit (PHIT), a software framework which eases app implementation and facilitates scientific evaluation. PHIT integrates self-report and physiological sensor instruments, evidence-based advisor logic, and self-help interventions such as meditation, health education, and cognitive behavior change. PHIT can be used to facilitate research, interventions for chronic diseases, risky behaviors, sleep, medication adherence, environmental monitoring, momentary data collection health screening, and clinical decision support. In a series of usability evaluations, participants reported an overall usability score of 4.5 on a 1-5 Likert scale and an 85 score on the System Usability Scale, indicating a high percentile rank of 95%.

  17. Usability factors of mobile health application for chronic diseases

    NASA Astrophysics Data System (ADS)

    Zahra, Fatima; Hussain, Azham; Mohd, Haslina

    2016-08-01

    M-health has changed the conventional delivery system of health-care, permitting continuous, pervasive Health-care anywhere, anytime. Chronic disease apps are increasing, as many health workers, patients and clinicians already embracing smartphones in their comprehensive and diverse practices. There are lots of challenges and requirements that need to be addressed for mobile health applications to prevent or eliminate design problems and minimize potential threats for users, the proposed factors for chronic disease mobile applications can be used as a guide for app developers While, the usability testing, and evaluations of chronic disease apps have not yet touched the accuracy level of other web based applications. This study is being conducted to learn about challenges of m-health apps and to identify the factors that affect the usability of such applications.

  18. Usability Study of Two Collocated Prototype System Displays

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.

    2007-01-01

    Currently, most of the displays in control rooms can be categorized as status screens, alerts/procedures screens (or paper), or control screens (where the state of a component is changed by the operator). The primary focus of this line of research is to determine which pieces of information (status, alerts/procedures, and control) should be collocated. Two collocated displays were tested for ease of understanding in an automated desktop survey. This usability study was conducted as a prelude to a larger human-in-the-loop experiment in order to verify that the 2 new collocated displays were easy to learn and usable. The results indicate that while the DC display was preferred and yielded better performance than the MDO display, both collocated displays can be easily learned and used.

  19. Randomised controlled trial to evaluate the efficacy and usability of a computerised phone-based lifestyle coaching system for primary and secondary prevention of stroke.

    PubMed

    Spassova, Lübomira; Vittore, Debora; Droste, Dirk W; Rösch, Norbert

    2016-02-09

    One of the most effective current approaches to preventing stroke events is the reduction of lifestyle risk factors, such as unhealthy diet, physical inactivity and smoking. In this study, we assessed the efficacy and usability of the phone-based Computer-aided Prevention System (CAPSYS) in supporting the reduction of lifestyle-related risk factors. A single-centre two-arm clinical trial was performed between January 2013 and February 2014, based on individual follow-up periods of six months with 94 patients at high risk of stroke, randomly assigned to an intervention group (IC: 48; advised to use the CAPSYS system) or a standard care group (SC: 46). Study parameters, such as blood pressure, blood values (HDL, LDL, HbA1c, glycaemia and triglycerides), weight, height, physical activity as well as nutrition and smoking habits were captured through questionnaires and medical records at baseline and post-intervention and analysed to detect significant changes. The usability of the intervention was assessed based on the standardised System Usability Scale (SUS) complemented by a more system-specific user satisfaction and feedback questionnaire. The statistical evaluation of primary measures revealed significant decreases of systolic blood pressure (mean of the differences = -9 mmHg; p = 0.03; 95% CI = [-17.29, -0.71]), LDL (pseudo-median of the differences = -7.9 mg/dl; p = 0.04; 95% CI = [-18.5, -0.5]) and triglyceride values (pseudo-median of the differences = -12.5 mg/dl; p = 0.04; 95% CI = [-26, -0.5]) in the intervention group, while no such changes could be observed in the control group. Furthermore, we detected a statistically significant increase in self-reported fruit and vegetable consumption (pseudo-median of the differences = 5.4 servings/week; p = 0.04; 95% CI = [0.5, 10.5]) and a decrease in sweets consumption (pseudo-median of the differences = -2 servings/week; p = 0.04; 95% CI = [-4, -0.00001]) in the intervention group. The usability assessment showed that the CAPSYS system was, in general, highly accepted by the users (average SUS score: 80.1). The study provided encouraging results indicating that a computerised phone-based lifestyle coaching system, such as CAPSYS, can support the usual treatment in reducing cerebro-cardiovascular risk factors and that such an approach is well applicable in practice. ClinicalTrials.gov Identifier: NCT02444715.

  20. The Anti-RFI Design of Intelligent Electric Energy Meters with UHF RFID

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    In order to solve the existing artificial meter reading watt-hour meter industry is still slow and inventory of common problems, using the uhf radio frequency identification (RFID) technology and intelligent watt-hour meter depth fusion, which has a one-time read multiple tags, identification distance, high transmission rate, high reliability, etc, while retaining the original asset management functions, in order to ensure the uhf RFID and minimum impact on the operation of the intelligent watt-hour meter, proposed to improve the stability of the electric meter system while working at the same time, this paper designs the uhf RFID intelligent watt-hour meter radio frequency interference resistance, put forward to improve intelligent watt-hour meter electromagnetic compatibility design train of thought, and introduced its power and the hardware circuit design of printed circuit board, etc.

  1. Adapting an in-person patient-caregiver communication intervention to a tailored web-based format.

    PubMed

    Zulman, Donna M; Schafenacker, Ann; Barr, Kathryn L C; Moore, Ian T; Fisher, Jake; McCurdy, Kathryn; Derry, Holly A; Saunders, Edward W; An, Lawrence C; Northouse, Laurel

    2012-03-01

    Interventions that target cancer patients and their caregivers have been shown to improve patient-caregiver communication, support, and emotional well-being. To adapt an in-person communication intervention for cancer patients and caregivers to a web-based format, and to examine the usability and acceptability of the web-based program among representative users. A tailored, interactive web-based communication program for cancer patients and their family caregivers was developed based on an existing in-person, nurse-delivered intervention. The development process involved: (1) building a multidisciplinary team of content and web design experts, (2) combining key components of the in-person intervention with the unique tailoring and interactive features of a web-based platform, and (3) conducting focus groups and usability testing to obtain feedback from representative program users at multiple time points. Four focus groups with 2-3 patient-caregiver pairs per group (n = 22 total participants) and two iterations of usability testing with four patient-caregiver pairs per session (n = 16 total participants) were conducted. Response to the program's structure, design, and content was favorable, even among users who were older or had limited computer and Internet experience. The program received high ratings for ease of use and overall usability (mean System Usability Score of 89.5 out of 100). Many elements of a nurse-delivered patient-caregiver intervention can be successfully adapted to a web-based format. A multidisciplinary design team and an iterative evaluation process with representative users were instrumental in the development of a usable and well-received web-based program. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Usability and Safety in Electronic Medical Records Interface Design: A Review of Recent Literature and Guideline Formulation.

    PubMed

    Zahabi, Maryam; Kaber, David B; Swangnetr, Manida

    2015-08-01

    The objectives of this study were to (a) review electronic medical record (EMR) and related electronic health record (EHR) interface usability issues, (b) review how EMRs have been evaluated with safety analysis techniques along with any hazard recognition, and (c) formulate design guidelines and a concept for enhanced EMR interfaces with a focus on diagnosis and documentation processes. A major impact of information technology in health care has been the introduction of EMRs. Although numerous studies indicate use of EMRs to increase health care quality, there remain concerns with usability issues and safety. A literature search was conducted using Compendex, PubMed, CINAHL, and Web of Science databases to find EMR research published since 2000. Inclusion criteria included relevant English-language papers with subsets of keywords and any studies (manually) identified with a focus on EMR usability. Fifty studies met the inclusion criteria. Results revealed EMR and EHR usability problems to include violations of natural dialog, control consistency, effective use of language, effective information presentation, and customization principles as well as a lack of error prevention, minimization of cognitive load, and feedback. Studies focusing on EMR system safety made no objective assessments and applied only inductive reasoning methods for hazard recognition. On the basis of the identified usability problems and structure of safety analysis techniques, we provide EMR design guidelines and a design concept focused on the diagnosis process and documentation. The design guidelines and new interface concept can be used for prototyping and testing enhanced EMRs. © 2015, Human Factors and Ergonomics Society.

  3. An efficient approach to improve the usability of e-learning resources: the role of heuristic evaluation.

    PubMed

    Davids, Mogamat Razeen; Chikte, Usuf M E; Halperin, Mitchell L

    2013-09-01

    Optimizing the usability of e-learning materials is necessary to maximize their potential educational impact, but this is often neglected when time and other resources are limited, leading to the release of materials that cannot deliver the desired learning outcomes. As clinician-teachers in a resource-constrained environment, we investigated whether heuristic evaluation of our multimedia e-learning resource by a panel of experts would be an effective and efficient alternative to testing with end users. We engaged six inspectors, whose expertise included usability, e-learning, instructional design, medical informatics, and the content area of nephrology. They applied a set of commonly used heuristics to identify usability problems, assigning severity scores to each problem. The identification of serious problems was compared with problems previously found by user testing. The panel completed their evaluations within 1 wk and identified a total of 22 distinct usability problems, 11 of which were considered serious. The problems violated the heuristics of visibility of system status, user control and freedom, match with the real world, intuitive visual layout, consistency and conformity to standards, aesthetic and minimalist design, error prevention and tolerance, and help and documentation. Compared with user testing, heuristic evaluation found most, but not all, of the serious problems. Combining heuristic evaluation and user testing, with each involving a small number of participants, may be an effective and efficient way of improving the usability of e-learning materials. Heuristic evaluation should ideally be used first to identify the most obvious problems and, once these are fixed, should be followed by testing with typical end users.

  4. Patient-Reported Usability of Positive Airway Pressure Equipment Is Associated With Adherence in Older Adults

    PubMed Central

    Martin, Jennifer L.; Hays, Ron D.; Patterson, Emily S.; Aysola, Ravi; Col, Nananda; Mitchell, Michael N.; Truong, Cindy; Dzierzewski, Joseph M.; Jouldjian, Stella; Song, Yeonsu; Rodriguez, Juan Carlos; Josephson, Karen; Alessi, Cathy

    2017-01-01

    Abstract Study objectives: To examine the usability of positive airway pressure (PAP) devices and its association with PAP adherence among older adults with sleep-disordered breathing. Methods: We mailed questionnaires to patients aged ≥65 years prescribed PAP therapy during the prior 36 months from two large healthcare systems. Survey participants completed the Usability of Sleep Apnea Equipment-Positive Airway Pressure (USE-PAP) questionnaire, which assessed the usability of their PAP device. Other questionnaire items included demographics and self-rated health. We also abstracted adherence data (mean nightly hours of PAP use available from one site) and interface type from the electronic health record. Results: Five hundred sixty-four patients completed the survey (response rate = 33%). The mean USE-PAP score (0 = best to 100 = worst) was 20 (SD ± 20). Mean duration of PAP use (available in 189 respondents) was 5.2 hours per night (SD ± 2.0). In a nested regression model predicting nightly hours of PAP use, a 10-point (0.5 SD) increase in USE-PAP score corresponded to a 0.37 hour/night reduction in PAP use. The model including the USE-PAP score explained a significant proportion (R2 = 15%) of the variation in nightly hours of PAP use above and beyond demographics, self-reported health, and interface type (∆R2 = 12%). Conclusions: Our results demonstrate that PAP usability varies among older patients and is associated with PAP adherence, above and beyond other predictors of adherence. These results support measuring and improving PAP usability to further improve PAP adherence for older patients. PMID:28364429

  5. Brief Report: Adapting an In-Person Patient-Caregiver Communication Intervention to a Tailored Web-Based Format

    PubMed Central

    Zulman, Donna M.; Schafenacker, Ann; Barr, Kathryn L.C.; Moore, Ian T.; Fisher, Jake; McCurdy, Kathryn; Derry, Holly A.; Saunders, Edward W.; An, Lawrence C.; Northouse, Laurel

    2011-01-01

    Background Interventions that target cancer patients and their caregivers have been shown to improve communication, support, and emotional well-being. Objective To adapt an in-person communication intervention for cancer patients and caregivers to a web-based format, and to examine the usability and acceptability of the web-based program among representative users. Methods A tailored, interactive web-based communication program for cancer patients and their family caregivers was developed based on an existing in-person, nurse-delivered intervention. The development process involved: 1) building a multidisciplinary team of content and web design experts, 2) combining key components of the in-person intervention with the unique tailoring and interactive features of a web-based platform, and 3) conducting focus groups and usability testing to obtain feedback from representative program users at multiple time points. Results Four focus groups with 2 to 3 patient-caregiver pairs per group (n = 22 total participants) and two iterations of usability testing with 4 patient-caregiver pairs per session (n = 16 total participants) were conducted. Response to the program's structure, design, and content was favorable, even among users who were older or had limited computer and internet experience. The program received high ratings for ease of use and overall usability (mean System Usability Score of 89.5 out of 100). Conclusions Many elements of a nurse-delivered patient-caregiver intervention can be successfully adapted to a web-based format. A multidisciplinary design team and an iterative evaluation process with representative users were instrumental in the development of a usable and well-received web-based program. PMID:21830255

  6. 40 CFR 60.3 - Units and abbreviations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) System International (SI) units of measure: A—ampere g—gram Hz—hertz J—joule K—degree Kelvin kg—kilogram m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...

  7. 40 CFR 60.3 - Units and abbreviations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) System International (SI) units of measure: A—ampere g—gram Hz—hertz J—joule K—degree Kelvin kg—kilogram m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...

  8. 40 CFR 60.3 - Units and abbreviations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) System International (SI) units of measure: A—ampere g—gram Hz—hertz J—joule K—degree Kelvin kg—kilogram m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...

  9. 40 CFR 60.3 - Units and abbreviations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) System International (SI) units of measure: A—ampere g—gram Hz—hertz J—joule K—degree Kelvin kg—kilogram m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...

  10. Accuracy of Cycling Power Meters against a Mathematical Model of Treadmill Cycling.

    PubMed

    Maier, Thomas; Schmid, Lucas; Müller, Beat; Steiner, Thomas; Wehrlin, Jon Peter

    2017-06-01

    The aim of this study was to compare the accuracy among a high number of current mobile cycling power meters used by elite and recreational cyclists against a first principle-based mathematical model of treadmill cycling. 54 power meters from 9 manufacturers used by 32 cyclists were calibrated. While the cyclist coasted downhill on a motorised treadmill, a back-pulling system was adjusted to counter the downhill force. The system was then loaded 3 times with 4 different masses while the cyclist pedalled to keep his position. The mean deviation (trueness) to the model and coefficient of variation (precision) were analysed. The mean deviations of the power meters were -0.9±3.2% (mean±SD) with 6 power meters deviating by more than±5%. The coefficients of variation of the power meters were 1.2±0.9% (mean±SD), with Stages varying more than SRM (p<0.001) and PowerTap (p<0.001). In conclusion, current power meters used by elite and recreational cyclists vary considerably in their trueness; precision is generally high but differs between manufacturers. Calibrating and adjusting the trueness of every power meter against a first principle-based reference is advised for accurate measurements. © Georg Thieme Verlag KG Stuttgart · New York.

  11. STORM-SEWER FLOW MEASUREMENT AND RECORDING SYSTEM.

    USGS Publications Warehouse

    Kilpatrick, Frederick A.; Kaehrle, William R.

    1986-01-01

    A comprehensive study and development of instruments and techniques for measuring all components of flow in a storm-sewer drainage system were undertaken by the U. S. Geological Survey under the sponsorship of FHWA. The study involved laboratory and field calibration and testing of measuring flumes, pipe insert meters, weirs, and electromagnetic velocity meters as well as the development and calibration of pneumatic bubbler and pressure transducer head-measuring systems. Tracer dilution and acoustic-flowmeter measurements were used in field verification tests. A single micrologger was used to record data from all the instruments and also to activate on command the electromagnetic velocity meter and tracer dilution systems.

  12. Design and test of a 2m x 4m DART system

    NASA Technical Reports Server (NTRS)

    Tolomeo, J.; Loane, J.; Cross, G.; Tenerelli, D.; Sable, B.; Decker, T.; Nelson, T.; Joseph, B.; Windes, C.; Kokawa, D.; hide

    2003-01-01

    A 2 meter by 4 meter DART (dual anamorphic reflector telescope) system has been designed and fabricated using thin stretched mesh reflectors. This report documents the structural configuration, test preparation, test results, and analysis correlation.

  13. On-site flow calibration of turbine meters for natural gas custody transfer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ting, V.C.; Schexnayder, L.L.; Conkling, D.B.

    1991-05-01

    This paper presents the design criteria, performance characteristics, and calibration procedures relating to a turbine-meter flow-calibration facility used in the high-volume custody transfer of natural gas. The facility, located in Venice, LA, is owned and operated by Chevron U.S.A. Inc. and is used to meter sales volumes of up to 500 MMscf/D (14.16 {times} 10 std m{sup 3}/d) at a nominal operating pressure of 1,000 psig (6.9 MPa). The system includes three 12-in. (30.48 cm) turbine meters used for sales-volume measurement, a bank of sonic nozzles, and a master turbine meter connected in series with the sales meters. The sonicmore » nozzles and master meter serve as flow-proving and -calibration devices. sonic nozzles are recommended by the turbine-meter standard for meter calibration. This paper examines the performance of on-site calibration of gas turbine meters. The Venice facility successfully demonstrated that on-site calibration of gas-metering devices can ensure accurate gas-flow measurement under field conditions.« less

  14. Two laboratory methods for the calibration of GPS speed meters

    NASA Astrophysics Data System (ADS)

    Bai, Yin; Sun, Qiao; Du, Lei; Yu, Mei; Bai, Jie

    2015-01-01

    The set-ups of two calibration systems are presented to investigate calibration methods of GPS speed meters. The GPS speed meter calibrated is a special type of high accuracy speed meter for vehicles which uses Doppler demodulation of GPS signals to calculate the measured speed of a moving target. Three experiments are performed: including simulated calibration, field-test signal replay calibration, and in-field test comparison with an optical speed meter. The experiments are conducted at specific speeds in the range of 40-180 km h-1 with the same GPS speed meter as the device under calibration. The evaluation of measurement results validates both methods for calibrating GPS speed meters. The relative deviations between the measurement results of the GPS-based high accuracy speed meter and those of the optical speed meter are analyzed, and the equivalent uncertainty of the comparison is evaluated. The comparison results justify the utilization of GPS speed meters as reference equipment if no fewer than seven satellites are available. This study contributes to the widespread use of GPS-based high accuracy speed meters as legal reference equipment in traffic speed metrology.

  15. Smart Grid Integrity Attacks: Characterizations and Countermeasures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Annarita Giani; Eilyan Bitar; Miles McQueen

    2011-10-01

    Real power injections at loads and generators, and real power flows on selected lines in a transmission network are monitored, transmitted over a SCADA network to the system operator, and used in state estimation algorithms to make dispatch, re-balance and other energy management system [EMS] decisions. Coordinated cyber attacks of power meter readings can be arranged to be undetectable by any bad data detection algorithm. These unobservable attacks present a serious threat to grid operations. Of particular interest are sparse attacks that involve the compromise of a modest number of meter readings. An efficient algorithm to find all unobservable attacksmore » [under standard DC load flow approximations] involving the compromise of exactly two power injection meters and an arbitrary number of power meters on lines is presented. This requires O(n2m) flops for a power system with n buses and m line meters. If all lines are metered, there exist canonical forms that characterize all 3, 4, and 5-sparse unobservable attacks. These can be quickly detected in power systems using standard graph algorithms. Known secure phase measurement units [PMUs] can be used as countermeasures against an arbitrary collection of cyber attacks. Finding the minimum number of necessary PMUs is NP-hard. It is shown that p + 1 PMUs at carefully chosen buses are sufficient to neutralize a collection of p cyber attacks.« less

  16. Individuals Achieve More Accurate Results with Meters That Are Codeless and Employ Dynamic Electrochemistry

    PubMed Central

    Rao, Anoop; Wiley, Meg; Iyengar, Sridhar; Nadeau, Dan; Carnevale, Julie

    2010-01-01

    Background Studies have shown that controlling blood glucose can reduce the onset and progression of the long-term microvascular and neuropathic complications associated with the chronic course of diabetes mellitus. Improved glycemic control can be achieved by frequent testing combined with changes in medication, exercise, and diet. Technological advancements have enabled improvements in analytical accuracy of meters, and this paper explores two such parameters to which that accuracy can be attributed. Methods Four blood glucose monitoring systems (with or without dynamic electrochemistry algorithms, codeless or requiring coding prior to testing) were evaluated and compared with respect to their accuracy. Results Altogether, 108 blood glucose values were obtained for each system from 54 study participants and compared with the reference values. The analysis depicted in the International Organization for Standardization table format indicates that the devices with dynamic electrochemistry and the codeless feature had the highest proportion of acceptable results overall (System A, 101/103). Results were significant when compared at the 10% bias level with meters that were codeless and utilized static electrochemistry (p = .017) or systems that had static electrochemistry but needed coding (p = .008). Conclusions Analytical performance of these blood glucose meters differed significantly depending on their technologic features. Meters that utilized dynamic electrochemistry and did not require coding were more accurate than meters that used static electrochemistry or required coding. PMID:20167178

  17. Individuals achieve more accurate results with meters that are codeless and employ dynamic electrochemistry.

    PubMed

    Rao, Anoop; Wiley, Meg; Iyengar, Sridhar; Nadeau, Dan; Carnevale, Julie

    2010-01-01

    Studies have shown that controlling blood glucose can reduce the onset and progression of the long-term microvascular and neuropathic complications associated with the chronic course of diabetes mellitus. Improved glycemic control can be achieved by frequent testing combined with changes in medication, exercise, and diet. Technological advancements have enabled improvements in analytical accuracy of meters, and this paper explores two such parameters to which that accuracy can be attributed. Four blood glucose monitoring systems (with or without dynamic electrochemistry algorithms, codeless or requiring coding prior to testing) were evaluated and compared with respect to their accuracy. Altogether, 108 blood glucose values were obtained for each system from 54 study participants and compared with the reference values. The analysis depicted in the International Organization for Standardization table format indicates that the devices with dynamic electrochemistry and the codeless feature had the highest proportion of acceptable results overall (System A, 101/103). Results were significant when compared at the 10% bias level with meters that were codeless and utilized static electrochemistry (p = .017) or systems that had static electrochemistry but needed coding (p = .008). Analytical performance of these blood glucose meters differed significantly depending on their technologic features. Meters that utilized dynamic electrochemistry and did not require coding were more accurate than meters that used static electrochemistry or required coding. 2010 Diabetes Technology Society.

  18. "Think aloud" and "Near live" usability testing of two complex clinical decision support tools.

    PubMed

    Richardson, Safiya; Mishuris, Rebecca; O'Connell, Alexander; Feldstein, David; Hess, Rachel; Smith, Paul; McCullagh, Lauren; McGinn, Thomas; Mann, Devin

    2017-10-01

    Low provider adoption continues to be a significant barrier to realizing the potential of clinical decision support. "Think Aloud" and "Near Live" usability testing were conducted on two clinical decision support tools. Each was composed of an alert, a clinical prediction rule which estimated risk of either group A Streptococcus pharyngitis or pneumonia and an automatic order set based on risk. The objective of this study was to further understanding of the facilitators of usability and to evaluate the types of additional information gained from proceeding to "Near Live" testing after completing "Think Aloud". This was a qualitative observational study conducted at a large academic health care system with 12 primary care providers. During "Think Aloud" testing, participants were provided with written clinical scenarios and asked to verbalize their thought process while interacting with the tool. During "Near Live" testing participants interacted with a mock patient. Morae usability software was used to record full screen capture and audio during every session. Participant comments were placed into coding categories and analyzed for generalizable themes. Themes were compared across usability methods. "Think Aloud" and "Near Live" usability testing generated similar themes under the coding categories visibility, workflow, content, understand-ability and navigation. However, they generated significantly different themes under the coding categories usability, practical usefulness and medical usefulness. During both types of testing participants found the tool easier to use when important text was distinct in its appearance, alerts were passive and appropriately timed, content was up to date, language was clear and simple, and each component of the tool included obvious indicators of next steps. Participant comments reflected higher expectations for usability and usefulness during "Near Live" testing. For example, visit aids, such as automatically generated order sets, were felt to be less useful during "Near-Live" testing because they would not be all inclusive for the visit. These complementary types of usability testing generated unique and generalizable insights. Feedback during "Think Aloud" testing primarily helped to improve the tools' ease of use. The additional feedback from "Near Live" testing, which mimics a real clinical encounter, was helpful for eliciting key barriers and facilitators to provider workflow and adoption. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Evaluation of a Dry EEG System for Application of Passive Brain-Computer Interfaces in Autonomous Driving

    PubMed Central

    Zander, Thorsten O.; Andreessen, Lena M.; Berg, Angela; Bleuel, Maurice; Pawlitzki, Juliane; Zawallich, Lars; Krol, Laurens R.; Gramann, Klaus

    2017-01-01

    We tested the applicability and signal quality of a 16 channel dry electroencephalography (EEG) system in a laboratory environment and in a car under controlled, realistic conditions. The aim of our investigation was an estimation how well a passive Brain-Computer Interface (pBCI) can work in an autonomous driving scenario. The evaluation considered speed and accuracy of self-applicability by an untrained person, quality of recorded EEG data, shifts of electrode positions on the head after driving-related movements, usability, and complexity of the system as such and wearing comfort over time. An experiment was conducted inside and outside of a stationary vehicle with running engine, air-conditioning, and muted radio. Signal quality was sufficient for standard EEG analysis in the time and frequency domain as well as for the use in pBCIs. While the influence of vehicle-induced interferences to data quality was insignificant, driving-related movements led to strong shifts in electrode positions. In general, the EEG system used allowed for a fast self-applicability of cap and electrodes. The assessed usability of the system was still acceptable while the wearing comfort decreased strongly over time due to friction and pressure to the head. From these results we conclude that the evaluated system should provide the essential requirements for an application in an autonomous driving context. Nevertheless, further refinement is suggested to reduce shifts of the system due to body movements and increase the headset's usability and wearing comfort. PMID:28293184

  20. Evaluation of a Dry EEG System for Application of Passive Brain-Computer Interfaces in Autonomous Driving.

    PubMed

    Zander, Thorsten O; Andreessen, Lena M; Berg, Angela; Bleuel, Maurice; Pawlitzki, Juliane; Zawallich, Lars; Krol, Laurens R; Gramann, Klaus

    2017-01-01

    We tested the applicability and signal quality of a 16 channel dry electroencephalography (EEG) system in a laboratory environment and in a car under controlled, realistic conditions. The aim of our investigation was an estimation how well a passive Brain-Computer Interface (pBCI) can work in an autonomous driving scenario. The evaluation considered speed and accuracy of self-applicability by an untrained person, quality of recorded EEG data, shifts of electrode positions on the head after driving-related movements, usability, and complexity of the system as such and wearing comfort over time. An experiment was conducted inside and outside of a stationary vehicle with running engine, air-conditioning, and muted radio. Signal quality was sufficient for standard EEG analysis in the time and frequency domain as well as for the use in pBCIs. While the influence of vehicle-induced interferences to data quality was insignificant, driving-related movements led to strong shifts in electrode positions. In general, the EEG system used allowed for a fast self-applicability of cap and electrodes. The assessed usability of the system was still acceptable while the wearing comfort decreased strongly over time due to friction and pressure to the head. From these results we conclude that the evaluated system should provide the essential requirements for an application in an autonomous driving context. Nevertheless, further refinement is suggested to reduce shifts of the system due to body movements and increase the headset's usability and wearing comfort.

Top