Sample records for method correlation coefficients

  1. [Correlation coefficient-based classification method of hydrological dependence variability: With auto-regression model as example].

    PubMed

    Zhao, Yu Xi; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi

    2018-04-01

    Hydrological process evaluation is temporal dependent. Hydrological time series including dependence components do not meet the data consistency assumption for hydrological computation. Both of those factors cause great difficulty for water researches. Given the existence of hydrological dependence variability, we proposed a correlationcoefficient-based method for significance evaluation of hydrological dependence based on auto-regression model. By calculating the correlation coefficient between the original series and its dependence component and selecting reasonable thresholds of correlation coefficient, this method divided significance degree of dependence into no variability, weak variability, mid variability, strong variability, and drastic variability. By deducing the relationship between correlation coefficient and auto-correlation coefficient in each order of series, we found that the correlation coefficient was mainly determined by the magnitude of auto-correlation coefficient from the 1 order to p order, which clarified the theoretical basis of this method. With the first-order and second-order auto-regression models as examples, the reasonability of the deduced formula was verified through Monte-Carlo experiments to classify the relationship between correlation coefficient and auto-correlation coefficient. This method was used to analyze three observed hydrological time series. The results indicated the coexistence of stochastic and dependence characteristics in hydrological process.

  2. Estimation of the biserial correlation and its sampling variance for use in meta-analysis.

    PubMed

    Jacobs, Perke; Viechtbauer, Wolfgang

    2017-06-01

    Meta-analyses are often used to synthesize the findings of studies examining the correlational relationship between two continuous variables. When only dichotomous measurements are available for one of the two variables, the biserial correlation coefficient can be used to estimate the product-moment correlation between the two underlying continuous variables. Unlike the point-biserial correlation coefficient, biserial correlation coefficients can therefore be integrated with product-moment correlation coefficients in the same meta-analysis. The present article describes the estimation of the biserial correlation coefficient for meta-analytic purposes and reports simulation results comparing different methods for estimating the coefficient's sampling variance. The findings indicate that commonly employed methods yield inconsistent estimates of the sampling variance across a broad range of research situations. In contrast, consistent estimates can be obtained using two methods that appear to be unknown in the meta-analytic literature. A variance-stabilizing transformation for the biserial correlation coefficient is described that allows for the construction of confidence intervals for individual coefficients with close to nominal coverage probabilities in most of the examined conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Testing the Difference of Correlated Agreement Coefficients for Statistical Significance

    ERIC Educational Resources Information Center

    Gwet, Kilem L.

    2016-01-01

    This article addresses the problem of testing the difference between two correlated agreement coefficients for statistical significance. A number of authors have proposed methods for testing the difference between two correlated kappa coefficients, which require either the use of resampling methods or the use of advanced statistical modeling…

  4. Distance correlation methods for discovering associations in large astrophysical databases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martínez-Gómez, Elizabeth; Richards, Mercedes T.; Richards, Donald St. P., E-mail: elizabeth.martinez@itam.mx, E-mail: mrichards@astro.psu.edu, E-mail: richards@stat.psu.edu

    2014-01-20

    High-dimensional, large-sample astrophysical databases of galaxy clusters, such as the Chandra Deep Field South COMBO-17 database, provide measurements on many variables for thousands of galaxies and a range of redshifts. Current understanding of galaxy formation and evolution rests sensitively on relationships between different astrophysical variables; hence an ability to detect and verify associations or correlations between variables is important in astrophysical research. In this paper, we apply a recently defined statistical measure called the distance correlation coefficient, which can be used to identify new associations and correlations between astrophysical variables. The distance correlation coefficient applies to variables of any dimension,more » can be used to determine smaller sets of variables that provide equivalent astrophysical information, is zero only when variables are independent, and is capable of detecting nonlinear associations that are undetectable by the classical Pearson correlation coefficient. Hence, the distance correlation coefficient provides more information than the Pearson coefficient. We analyze numerous pairs of variables in the COMBO-17 database with the distance correlation method and with the maximal information coefficient. We show that the Pearson coefficient can be estimated with higher accuracy from the corresponding distance correlation coefficient than from the maximal information coefficient. For given values of the Pearson coefficient, the distance correlation method has a greater ability than the maximal information coefficient to resolve astrophysical data into highly concentrated horseshoe- or V-shapes, which enhances classification and pattern identification. These results are observed over a range of redshifts beyond the local universe and for galaxies from elliptical to spiral.« less

  5. A comparison of confidence interval methods for the intraclass correlation coefficient in community-based cluster randomization trials with a binary outcome.

    PubMed

    Braschel, Melissa C; Svec, Ivana; Darlington, Gerarda A; Donner, Allan

    2016-04-01

    Many investigators rely on previously published point estimates of the intraclass correlation coefficient rather than on their associated confidence intervals to determine the required size of a newly planned cluster randomized trial. Although confidence interval methods for the intraclass correlation coefficient that can be applied to community-based trials have been developed for a continuous outcome variable, fewer methods exist for a binary outcome variable. The aim of this study is to evaluate confidence interval methods for the intraclass correlation coefficient applied to binary outcomes in community intervention trials enrolling a small number of large clusters. Existing methods for confidence interval construction are examined and compared to a new ad hoc approach based on dividing clusters into a large number of smaller sub-clusters and subsequently applying existing methods to the resulting data. Monte Carlo simulation is used to assess the width and coverage of confidence intervals for the intraclass correlation coefficient based on Smith's large sample approximation of the standard error of the one-way analysis of variance estimator, an inverted modified Wald test for the Fleiss-Cuzick estimator, and intervals constructed using a bootstrap-t applied to a variance-stabilizing transformation of the intraclass correlation coefficient estimate. In addition, a new approach is applied in which clusters are randomly divided into a large number of smaller sub-clusters with the same methods applied to these data (with the exception of the bootstrap-t interval, which assumes large cluster sizes). These methods are also applied to a cluster randomized trial on adolescent tobacco use for illustration. When applied to a binary outcome variable in a small number of large clusters, existing confidence interval methods for the intraclass correlation coefficient provide poor coverage. However, confidence intervals constructed using the new approach combined with Smith's method provide nominal or close to nominal coverage when the intraclass correlation coefficient is small (<0.05), as is the case in most community intervention trials. This study concludes that when a binary outcome variable is measured in a small number of large clusters, confidence intervals for the intraclass correlation coefficient may be constructed by dividing existing clusters into sub-clusters (e.g. groups of 5) and using Smith's method. The resulting confidence intervals provide nominal or close to nominal coverage across a wide range of parameters when the intraclass correlation coefficient is small (<0.05). Application of this method should provide investigators with a better understanding of the uncertainty associated with a point estimator of the intraclass correlation coefficient used for determining the sample size needed for a newly designed community-based trial. © The Author(s) 2015.

  6. Random matrix theory analysis of cross-correlations in the US stock market: Evidence from Pearson’s correlation coefficient and detrended cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Wang, Gang-Jin; Xie, Chi; Chen, Shou; Yang, Jiao-Jiao; Yang, Ming-Yan

    2013-09-01

    In this study, we first build two empirical cross-correlation matrices in the US stock market by two different methods, namely the Pearson’s correlation coefficient and the detrended cross-correlation coefficient (DCCA coefficient). Then, combining the two matrices with the method of random matrix theory (RMT), we mainly investigate the statistical properties of cross-correlations in the US stock market. We choose the daily closing prices of 462 constituent stocks of S&P 500 index as the research objects and select the sample data from January 3, 2005 to August 31, 2012. In the empirical analysis, we examine the statistical properties of cross-correlation coefficients, the distribution of eigenvalues, the distribution of eigenvector components, and the inverse participation ratio. From the two methods, we find some new results of the cross-correlations in the US stock market in our study, which are different from the conclusions reached by previous studies. The empirical cross-correlation matrices constructed by the DCCA coefficient show several interesting properties at different time scales in the US stock market, which are useful to the risk management and optimal portfolio selection, especially to the diversity of the asset portfolio. It will be an interesting and meaningful work to find the theoretical eigenvalue distribution of a completely random matrix R for the DCCA coefficient because it does not obey the Marčenko-Pastur distribution.

  7. 40 CFR 53.34 - Test procedure for methods for PM10 and Class I methods for PM2.5.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... linear regression parameters (slope, intercept, and correlation coefficient) describing the relationship... correlation coefficient. (2) To pass the test for comparability, the slope, intercept, and correlation...

  8. Two-Way Gene Interaction From Microarray Data Based on Correlation Methods.

    PubMed

    Alavi Majd, Hamid; Talebi, Atefeh; Gilany, Kambiz; Khayyer, Nasibeh

    2016-06-01

    Gene networks have generated a massive explosion in the development of high-throughput techniques for monitoring various aspects of gene activity. Networks offer a natural way to model interactions between genes, and extracting gene network information from high-throughput genomic data is an important and difficult task. The purpose of this study is to construct a two-way gene network based on parametric and nonparametric correlation coefficients. The first step in constructing a Gene Co-expression Network is to score all pairs of gene vectors. The second step is to select a score threshold and connect all gene pairs whose scores exceed this value. In the foundation-application study, we constructed two-way gene networks using nonparametric methods, such as Spearman's rank correlation coefficient and Blomqvist's measure, and compared them with Pearson's correlation coefficient. We surveyed six genes of venous thrombosis disease, made a matrix entry representing the score for the corresponding gene pair, and obtained two-way interactions using Pearson's correlation, Spearman's rank correlation, and Blomqvist's coefficient. Finally, these methods were compared with Cytoscape, based on BIND, and Gene Ontology, based on molecular function visual methods; R software version 3.2 and Bioconductor were used to perform these methods. Based on the Pearson and Spearman correlations, the results were the same and were confirmed by Cytoscape and GO visual methods; however, Blomqvist's coefficient was not confirmed by visual methods. Some results of the correlation coefficients are not the same with visualization. The reason may be due to the small number of data.

  9. Identification of Correlated GRACE Monthly Harmonic Coefficients Using Pattern Recognition and Neural Networks

    NASA Astrophysics Data System (ADS)

    Piretzidis, D.; Sra, G.; Sideris, M. G.

    2016-12-01

    This study explores new methods for identifying correlation errors in harmonic coefficients derived from monthly solutions of the Gravity Recovery and Climate Experiment (GRACE) satellite mission using pattern recognition and neural network algorithms. These correlation errors are evidenced in the differences between monthly solutions and can be suppressed using a de-correlation filter. In all studies so far, the implementation of the de-correlation filter starts from a specific minimum order (i.e., 11 for RL04 and 38 for RL05) until the maximum order of the monthly solution examined. This implementation method has two disadvantages, namely, the omission of filtering correlated coefficients of order less than the minimum order and the filtering of uncorrelated coefficients of order higher than the minimum order. In the first case, the filtered solution is not completely free of correlated errors, whereas the second case results in a monthly solution that suffers from loss of geophysical signal. In the present study, a new method of implementing the de-correlation filter is suggested, by identifying and filtering only the coefficients that show indications of high correlation. Several numerical and geometric properties of the harmonic coefficient series of all orders are examined. Extreme cases of both correlated and uncorrelated coefficients are selected, and their corresponding properties are used to train a two-layer feed-forward neural network. The objective of the neural network is to identify and quantify the correlation by providing the probability of an order of coefficients to be correlated. Results show good performance of the neural network, both in the validation stage of the training procedure and in the subsequent use of the trained network to classify independent coefficients. The neural network is also capable of identifying correlated coefficients even when a small number of training samples and neurons are used (e.g.,100 and 10, respectively).

  10. Identifying presence of correlated errors in GRACE monthly harmonic coefficients using machine learning algorithms

    NASA Astrophysics Data System (ADS)

    Piretzidis, Dimitrios; Sra, Gurveer; Karantaidis, George; Sideris, Michael G.

    2017-04-01

    A new method for identifying correlated errors in Gravity Recovery and Climate Experiment (GRACE) monthly harmonic coefficients has been developed and tested. Correlated errors are present in the differences between monthly GRACE solutions, and can be suppressed using a de-correlation filter. In principle, the de-correlation filter should be implemented only on coefficient series with correlated errors to avoid losing useful geophysical information. In previous studies, two main methods of implementing the de-correlation filter have been utilized. In the first one, the de-correlation filter is implemented starting from a specific minimum order until the maximum order of the monthly solution examined. In the second one, the de-correlation filter is implemented only on specific coefficient series, the selection of which is based on statistical testing. The method proposed in the present study exploits the capabilities of supervised machine learning algorithms such as neural networks and support vector machines (SVMs). The pattern of correlated errors can be described by several numerical and geometric features of the harmonic coefficient series. The features of extreme cases of both correlated and uncorrelated coefficients are extracted and used for the training of the machine learning algorithms. The trained machine learning algorithms are later used to identify correlated errors and provide the probability of a coefficient series to be correlated. Regarding SVMs algorithms, an extensive study is performed with various kernel functions in order to find the optimal training model for prediction. The selection of the optimal training model is based on the classification accuracy of the trained SVM algorithm on the same samples used for training. Results show excellent performance of all algorithms with a classification accuracy of 97% - 100% on a pre-selected set of training samples, both in the validation stage of the training procedure and in the subsequent use of the trained algorithms to classify independent coefficients. This accuracy is also confirmed by the external validation of the trained algorithms using the hydrology model GLDAS NOAH. The proposed method meet the requirement of identifying and de-correlating only coefficients with correlated errors. Also, there is no need of applying statistical testing or other techniques that require prior de-correlation of the harmonic coefficients.

  11. Two-Way Gene Interaction From Microarray Data Based on Correlation Methods

    PubMed Central

    Alavi Majd, Hamid; Talebi, Atefeh; Gilany, Kambiz; Khayyer, Nasibeh

    2016-01-01

    Background Gene networks have generated a massive explosion in the development of high-throughput techniques for monitoring various aspects of gene activity. Networks offer a natural way to model interactions between genes, and extracting gene network information from high-throughput genomic data is an important and difficult task. Objectives The purpose of this study is to construct a two-way gene network based on parametric and nonparametric correlation coefficients. The first step in constructing a Gene Co-expression Network is to score all pairs of gene vectors. The second step is to select a score threshold and connect all gene pairs whose scores exceed this value. Materials and Methods In the foundation-application study, we constructed two-way gene networks using nonparametric methods, such as Spearman’s rank correlation coefficient and Blomqvist’s measure, and compared them with Pearson’s correlation coefficient. We surveyed six genes of venous thrombosis disease, made a matrix entry representing the score for the corresponding gene pair, and obtained two-way interactions using Pearson’s correlation, Spearman’s rank correlation, and Blomqvist’s coefficient. Finally, these methods were compared with Cytoscape, based on BIND, and Gene Ontology, based on molecular function visual methods; R software version 3.2 and Bioconductor were used to perform these methods. Results Based on the Pearson and Spearman correlations, the results were the same and were confirmed by Cytoscape and GO visual methods; however, Blomqvist’s coefficient was not confirmed by visual methods. Conclusions Some results of the correlation coefficients are not the same with visualization. The reason may be due to the small number of data. PMID:27621916

  12. Detrended partial cross-correlation analysis of two nonstationary time series influenced by common external forces

    NASA Astrophysics Data System (ADS)

    Qian, Xi-Yuan; Liu, Ya-Min; Jiang, Zhi-Qiang; Podobnik, Boris; Zhou, Wei-Xing; Stanley, H. Eugene

    2015-06-01

    When common factors strongly influence two power-law cross-correlated time series recorded in complex natural or social systems, using detrended cross-correlation analysis (DCCA) without considering these common factors will bias the results. We use detrended partial cross-correlation analysis (DPXA) to uncover the intrinsic power-law cross correlations between two simultaneously recorded time series in the presence of nonstationarity after removing the effects of other time series acting as common forces. The DPXA method is a generalization of the detrended cross-correlation analysis that takes into account partial correlation analysis. We demonstrate the method by using bivariate fractional Brownian motions contaminated with a fractional Brownian motion. We find that the DPXA is able to recover the analytical cross Hurst indices, and thus the multiscale DPXA coefficients are a viable alternative to the conventional cross-correlation coefficient. We demonstrate the advantage of the DPXA coefficients over the DCCA coefficients by analyzing contaminated bivariate fractional Brownian motions. We calculate the DPXA coefficients and use them to extract the intrinsic cross correlation between crude oil and gold futures by taking into consideration the impact of the U.S. dollar index. We develop the multifractal DPXA (MF-DPXA) method in order to generalize the DPXA method and investigate multifractal time series. We analyze multifractal binomial measures masked with strong white noises and find that the MF-DPXA method quantifies the hidden multifractal nature while the multifractal DCCA method fails.

  13. A Method for Approximating the Bivariate Normal Correlation Coefficient.

    ERIC Educational Resources Information Center

    Kirk, David B.

    Improvements of the Gaussian quadrature in conjunction with the Newton-Raphson iteration technique (TM 000 789) are discussed as effective methods of calculating the bivariate normal correlation coefficient. (CK)

  14. Feature Genes Selection Using Supervised Locally Linear Embedding and Correlation Coefficient for Microarray Classification

    PubMed Central

    Wang, Yun; Huang, Fangzhou

    2018-01-01

    The selection of feature genes with high recognition ability from the gene expression profiles has gained great significance in biology. However, most of the existing methods have a high time complexity and poor classification performance. Motivated by this, an effective feature selection method, called supervised locally linear embedding and Spearman's rank correlation coefficient (SLLE-SC2), is proposed which is based on the concept of locally linear embedding and correlation coefficient algorithms. Supervised locally linear embedding takes into account class label information and improves the classification performance. Furthermore, Spearman's rank correlation coefficient is used to remove the coexpression genes. The experiment results obtained on four public tumor microarray datasets illustrate that our method is valid and feasible. PMID:29666661

  15. Feature Genes Selection Using Supervised Locally Linear Embedding and Correlation Coefficient for Microarray Classification.

    PubMed

    Xu, Jiucheng; Mu, Huiyu; Wang, Yun; Huang, Fangzhou

    2018-01-01

    The selection of feature genes with high recognition ability from the gene expression profiles has gained great significance in biology. However, most of the existing methods have a high time complexity and poor classification performance. Motivated by this, an effective feature selection method, called supervised locally linear embedding and Spearman's rank correlation coefficient (SLLE-SC 2 ), is proposed which is based on the concept of locally linear embedding and correlation coefficient algorithms. Supervised locally linear embedding takes into account class label information and improves the classification performance. Furthermore, Spearman's rank correlation coefficient is used to remove the coexpression genes. The experiment results obtained on four public tumor microarray datasets illustrate that our method is valid and feasible.

  16. Factors That Attenuate the Correlation Coefficient and Its Analogs.

    ERIC Educational Resources Information Center

    Dolenz, Beverly

    The correlation coefficient is an integral part of many other statistical techniques (analysis of variance, t-tests, etc.), since all analytic methods are actually correlational (G. V. Glass and K. D. Hopkins, 1984). The correlation coefficient is a statistical summary that represents the degree and direction of relationship between two variables.…

  17. Genome-scale cluster analysis of replicated microarrays using shrinkage correlation coefficient.

    PubMed

    Yao, Jianchao; Chang, Chunqi; Salmi, Mari L; Hung, Yeung Sam; Loraine, Ann; Roux, Stanley J

    2008-06-18

    Currently, clustering with some form of correlation coefficient as the gene similarity metric has become a popular method for profiling genomic data. The Pearson correlation coefficient and the standard deviation (SD)-weighted correlation coefficient are the two most widely-used correlations as the similarity metrics in clustering microarray data. However, these two correlations are not optimal for analyzing replicated microarray data generated by most laboratories. An effective correlation coefficient is needed to provide statistically sufficient analysis of replicated microarray data. In this study, we describe a novel correlation coefficient, shrinkage correlation coefficient (SCC), that fully exploits the similarity between the replicated microarray experimental samples. The methodology considers both the number of replicates and the variance within each experimental group in clustering expression data, and provides a robust statistical estimation of the error of replicated microarray data. The value of SCC is revealed by its comparison with two other correlation coefficients that are currently the most widely-used (Pearson correlation coefficient and SD-weighted correlation coefficient) using statistical measures on both synthetic expression data as well as real gene expression data from Saccharomyces cerevisiae. Two leading clustering methods, hierarchical and k-means clustering were applied for the comparison. The comparison indicated that using SCC achieves better clustering performance. Applying SCC-based hierarchical clustering to the replicated microarray data obtained from germinating spores of the fern Ceratopteris richardii, we discovered two clusters of genes with shared expression patterns during spore germination. Functional analysis suggested that some of the genetic mechanisms that control germination in such diverse plant lineages as mosses and angiosperms are also conserved among ferns. This study shows that SCC is an alternative to the Pearson correlation coefficient and the SD-weighted correlation coefficient, and is particularly useful for clustering replicated microarray data. This computational approach should be generally useful for proteomic data or other high-throughput analysis methodology.

  18. Correlation coefficient measurement of the mode-locked laser tones using four-wave mixing.

    PubMed

    Anthur, Aravind P; Panapakkam, Vivek; Vujicic, Vidak; Merghem, Kamel; Lelarge, Francois; Ramdane, Abderrahim; Barry, Liam P

    2016-06-01

    We use four-wave mixing to measure the correlation coefficient of comb tones in a quantum-dash mode-locked laser under passive and active locked regimes. We study the uncertainty in the measurement of the correlation coefficient of the proposed method.

  19. [Electroencephalogram Feature Selection Based on Correlation Coefficient Analysis].

    PubMed

    Zhou, Jinzhi; Tang, Xiaofang

    2015-08-01

    In order to improve the accuracy of classification with small amount of motor imagery training data on the development of brain-computer interface (BCD systems, we proposed an analyzing method to automatically select the characteristic parameters based on correlation coefficient analysis. Throughout the five sample data of dataset IV a from 2005 BCI Competition, we utilized short-time Fourier transform (STFT) and correlation coefficient calculation to reduce the number of primitive electroencephalogram dimension, then introduced feature extraction based on common spatial pattern (CSP) and classified by linear discriminant analysis (LDA). Simulation results showed that the average rate of classification accuracy could be improved by using correlation coefficient feature selection method than those without using this algorithm. Comparing with support vector machine (SVM) optimization features algorithm, the correlation coefficient analysis can lead better selection parameters to improve the accuracy of classification.

  20. Clustering Coefficients for Correlation Networks.

    PubMed

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties.

  1. Clustering Coefficients for Correlation Networks

    PubMed Central

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties. PMID:29599714

  2. Statistics corner: A guide to appropriate use of correlation coefficient in medical research.

    PubMed

    Mukaka, M M

    2012-09-01

    Correlation is a statistical method used to assess a possible linear association between two continuous variables. It is simple both to calculate and to interpret. However, misuse of correlation is so common among researchers that some statisticians have wished that the method had never been devised at all. The aim of this article is to provide a guide to appropriate use of correlation in medical research and to highlight some misuse. Examples of the applications of the correlation coefficient have been provided using data from statistical simulations as well as real data. Rule of thumb for interpreting size of a correlation coefficient has been provided.

  3. Thin and Slow Smoke Detection by Using Frequency Image

    NASA Astrophysics Data System (ADS)

    Zheng, Guang; Oe, Shunitiro

    In this paper, a new method to detect thin and slow smoke for early fire alarm by using frequency image has been proposed. The correlation coefficient of the frequency image between the current stage and the initial stage are calculated, so are the gray image correlation coefficient of the color image. When the thin smoke close to transparent enters into the camera view, the correlation coefficient of the frequency image becomes small, while the gray image correlation coefficient of the color image hardly change and keep large. When something which is not transparent, like human beings, etc., enters into the camera view, the correlation coefficient of the frequency image becomes small, as well as that of color image. Based on the difference of correlation coefficient between frequency image and color image in different situations, the thin smoke can be detected. Also, considering the movement of the thin smoke, miss detection caused by the illustration change or noise can be avoided. Several experiments in different situations are carried out, and the experimental results show the effect of the proposed method.

  4. Information-theoretic indices usage for the prediction and calculation of octanol-water partition coefficient.

    PubMed

    Persona, Marek; Kutarov, Vladimir V; Kats, Boris M; Persona, Andrzej; Marczewska, Barbara

    2007-01-01

    The paper describes the new prediction method of octanol-water partition coefficient, which is based on molecular graph theory. The results obtained using the new method are well correlated with experimental values. These results were compared with the ones obtained by use of ten other structure correlated methods. The comparison shows that graph theory can be very useful in structure correlation research.

  5. An asymptotic theory for cross-correlation between auto-correlated sequences and its application on neuroimaging data.

    PubMed

    Zhou, Yunyi; Tao, Chenyang; Lu, Wenlian; Feng, Jianfeng

    2018-04-20

    Functional connectivity is among the most important tools to study brain. The correlation coefficient, between time series of different brain areas, is the most popular method to quantify functional connectivity. Correlation coefficient in practical use assumes the data to be temporally independent. However, the time series data of brain can manifest significant temporal auto-correlation. A widely applicable method is proposed for correcting temporal auto-correlation. We considered two types of time series models: (1) auto-regressive-moving-average model, (2) nonlinear dynamical system model with noisy fluctuations, and derived their respective asymptotic distributions of correlation coefficient. These two types of models are most commonly used in neuroscience studies. We show the respective asymptotic distributions share a unified expression. We have verified the validity of our method, and shown our method exhibited sufficient statistical power for detecting true correlation on numerical experiments. Employing our method on real dataset yields more robust functional network and higher classification accuracy than conventional methods. Our method robustly controls the type I error while maintaining sufficient statistical power for detecting true correlation in numerical experiments, where existing methods measuring association (linear and nonlinear) fail. In this work, we proposed a widely applicable approach for correcting the effect of temporal auto-correlation on functional connectivity. Empirical results favor the use of our method in functional network analysis. Copyright © 2018. Published by Elsevier B.V.

  6. Cumulative query method for influenza surveillance using search engine data.

    PubMed

    Seo, Dong-Woo; Jo, Min-Woo; Sohn, Chang Hwan; Shin, Soo-Yong; Lee, JaeHo; Yu, Maengsoo; Kim, Won Young; Lim, Kyoung Soo; Lee, Sang-Il

    2014-12-16

    Internet search queries have become an important data source in syndromic surveillance system. However, there is currently no syndromic surveillance system using Internet search query data in South Korea. The objective of this study was to examine correlations between our cumulative query method and national influenza surveillance data. Our study was based on the local search engine, Daum (approximately 25% market share), and influenza-like illness (ILI) data from the Korea Centers for Disease Control and Prevention. A quota sampling survey was conducted with 200 participants to obtain popular queries. We divided the study period into two sets: Set 1 (the 2009/10 epidemiological year for development set 1 and 2010/11 for validation set 1) and Set 2 (2010/11 for development Set 2 and 2011/12 for validation Set 2). Pearson's correlation coefficients were calculated between the Daum data and the ILI data for the development set. We selected the combined queries for which the correlation coefficients were .7 or higher and listed them in descending order. Then, we created a cumulative query method n representing the number of cumulative combined queries in descending order of the correlation coefficient. In validation set 1, 13 cumulative query methods were applied, and 8 had higher correlation coefficients (min=.916, max=.943) than that of the highest single combined query. Further, 11 of 13 cumulative query methods had an r value of ≥.7, but 4 of 13 combined queries had an r value of ≥.7. In validation set 2, 8 of 15 cumulative query methods showed higher correlation coefficients (min=.975, max=.987) than that of the highest single combined query. All 15 cumulative query methods had an r value of ≥.7, but 6 of 15 combined queries had an r value of ≥.7. Cumulative query method showed relatively higher correlation with national influenza surveillance data than combined queries in the development and validation set.

  7. Optimal portfolio strategy with cross-correlation matrix composed by DCCA coefficients: Evidence from the Chinese stock market

    NASA Astrophysics Data System (ADS)

    Sun, Xuelian; Liu, Zixian

    2016-02-01

    In this paper, a new estimator of correlation matrix is proposed, which is composed of the detrended cross-correlation coefficients (DCCA coefficients), to improve portfolio optimization. In contrast to Pearson's correlation coefficients (PCC), DCCA coefficients acquired by the detrended cross-correlation analysis (DCCA) method can describe the nonlinear correlation between assets, and can be decomposed in different time scales. These properties of DCCA make it possible to improve the investment effect and more valuable to investigate the scale behaviors of portfolios. The minimum variance portfolio (MVP) model and the Mean-Variance (MV) model are used to evaluate the effectiveness of this improvement. Stability analysis shows the effect of two kinds of correlation matrices on the estimation error of portfolio weights. The observed scale behaviors are significant to risk management and could be used to optimize the portfolio selection.

  8. Prediction of Very High Reynolds Number Compressible Skin Friction

    NASA Technical Reports Server (NTRS)

    Carlson, John R.

    1998-01-01

    Flat plate skin friction calculations over a range of Mach numbers from 0.4 to 3.5 at Reynolds numbers from 16 million to 492 million using a Navier Stokes method with advanced turbulence modeling are compared with incompressible skin friction coefficient correlations. The semi-empirical correlation theories of van Driest; Cope; Winkler and Cha; and Sommer and Short T' are used to transform the predicted skin friction coefficients of solutions using two algebraic Reynolds stress turbulence models in the Navier-Stokes method PAB3D. In general, the predicted skin friction coefficients scaled well with each reference temperature theory though, overall the theory by Sommer and Short appeared to best collapse the predicted coefficients. At the lower Reynolds number 3 to 30 million, both the Girimaji and Shih, Zhu and Lumley turbulence models predicted skin-friction coefficients within 2% of the semi-empirical correlation skin friction coefficients. At the higher Reynolds numbers of 100 to 500 million, the turbulence models by Shih, Zhu and Lumley and Girimaji predicted coefficients that were 6% less and 10% greater, respectively, than the semi-empirical coefficients.

  9. Five radiographic methods for assessing skeletal maturity in a Spanish population: is there a correlation?

    PubMed

    Camacho-Basallo, Paula; Yáñez-Vico, Rosa-María; Solano-Reina, Enrique; Iglesias-Linares, Alejandro

    2017-03-01

    The need for accurate techniques of estimating age has sharply increased in line with the rise in illegal migration and the political, economic and socio-demographic problems that this poses in developed countries today. The methods routinely employed for determining chronological age are mainly based on determining skeletal maturation using radiological techniques. The objective of this study was to correlate five different methods for assessing skeletal maturation. 606 radiographs of growing patients were analyzed, and each patient was classified according to two cervical vertebral-based methods, two hand-wrist-based methods and one tooth-based method. Spearman's rank-order correlation coefficient was applied to assess the relationship between chronological age and the five methods of assessing maturation, as well as correlations between the five methods (p < 0.05). Spearman's rank correlation coefficients for chronological age and cervical vertebral maturation stage using both methods were 0.656/0.693 (p < 0.001), respectively, for males. For females, the correlation was stronger for both methods. The correlation coefficients for chronological age against the two hand-wrist assessment methods were statistically significant only for Fishman's method, 0.722 (p < 0.001) and 0.839 (p < 0.001), respectively for males and females. The cervical vertebral, hand-wrist and dental maturation methods of assessment were all found to correlate strongly with each other, irrespective of gender, except for Grave and Brown's method. The results found the strongest correlation between the second molars and females, and the second premolar and males. This study sheds light on and correlates with the five radiographic methods most commonly used for assessing skeletal maturation in a Spanish population in southern Europe.

  10. Estimation of Comfort/Disconfort Based on EEG in Massage by Use of Clustering according to Correration and Incremental Learning type NN

    NASA Astrophysics Data System (ADS)

    Teramae, Tatsuya; Kushida, Daisuke; Takemori, Fumiaki; Kitamura, Akira

    Authors proposed the estimation method combining k-means algorithm and NN for evaluating massage. However, this estimation method has a problem that discrimination ratio is decreased to new user. There are two causes of this problem. One is that generalization of NN is bad. Another one is that clustering result by k-means algorithm has not high correlation coefficient in a class. Then, this research proposes k-means algorithm according to correlation coefficient and incremental learning for NN. The proposed k-means algorithm is method included evaluation function based on correlation coefficient. Incremental learning is method that NN is learned by new data and initialized weight based on the existing data. The effect of proposed methods are verified by estimation result using EEG data when testee is given massage.

  11. Correlation time and diffusion coefficient imaging: application to a granular flow system.

    PubMed

    Caprihan, A; Seymour, J D

    2000-05-01

    A parametric method for spatially resolved measurements for velocity autocorrelation functions, R(u)(tau) = , expressed as a sum of exponentials, is presented. The method is applied to a granular flow system of 2-mm oil-filled spheres rotated in a half-filled horizontal cylinder, which is an Ornstein-Uhlenbeck process with velocity autocorrelation function R(u)(tau) = e(- ||tau ||/tau(c)), where tau(c) is the correlation time and D = tau(c) is the diffusion coefficient. The pulsed-field-gradient NMR method consists of applying three different gradient pulse sequences of varying motion sensitivity to distinguish the range of correlation times present for particle motion. Time-dependent apparent diffusion coefficients are measured for these three sequences and tau(c) and D are then calculated from the apparent diffusion coefficient images. For the cylinder rotation rate of 2.3 rad/s, the axial diffusion coefficient at the top center of the free surface was 5.5 x 10(-6) m(2)/s, the correlation time was 3 ms, and the velocity fluctuation or granular temperature was 1.8 x 10(-3) m(2)/s(2). This method is also applicable to study transport in systems involving turbulence and porous media flows. Copyright 2000 Academic Press.

  12. A New Methodology of Spatial Cross-Correlation Analysis

    PubMed Central

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran’s index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson’s correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China’s urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes. PMID:25993120

  13. A new methodology of spatial cross-correlation analysis.

    PubMed

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran's index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson's correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China's urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes.

  14. [Dental arch form reverting by four-point method].

    PubMed

    Pan, Xiao-Gang; Qian, Yu-Fen; Weng, Si-En; Feng, Qi-Ping; Yu, Quan

    2008-04-01

    To explore a simple method of reverting individual dental arch form template for wire bending. Individual dental arch form was reverted by four-point method. By defining central point of bracket on bilateral lower second premolar and first molar, certain individual dental arch form could be generated. The arch form generating procedure was then be developed to computer software for printing arch form. Four-point method arch form was evaluated by comparing with direct model measurement on linear and angular parameters. The accuracy and reproducibility were assessed by paired t test and concordance correlation coefficient with Medcalc 9.3 software package. The arch form by four-point method was of good accuracy and reproducibility (linear concordance correlation coefficient was 0.9909 and angular concordance correlation coefficient was 0.8419). The dental arch form reverted by four-point method could reproduce the individual dental arch form.

  15. An improved method based on wavelet coefficient correlation to filter noise in Doppler ultrasound blood flow signals

    NASA Astrophysics Data System (ADS)

    Wan, Renzhi; Zu, Yunxiao; Shao, Lin

    2018-04-01

    The blood echo signal maintained through Medical ultrasound Doppler devices would always include vascular wall pulsation signal .The traditional method to de-noise wall signal is using high-pass filter, which will also remove the lowfrequency part of the blood flow signal. Some scholars put forward a method based on region selective reduction, which at first estimates of the wall pulsation signals and then removes the wall signal from the mixed signal. Apparently, this method uses the correlation between wavelet coefficients to distinguish blood signal from wall signal, but in fact it is a kind of wavelet threshold de-noising method, whose effect is not so much ideal. In order to maintain a better effect, this paper proposes an improved method based on wavelet coefficient correlation to separate blood signal and wall signal, and simulates the algorithm by computer to verify its validity.

  16. Transcultural adaptation and psychometric properties of Spanish version of Pregnancy Physical Activity Questionnaire: the PregnActive project.

    PubMed

    Oviedo-Caro, Miguel Ángel; Bueno-Antequera, Javier; Munguía-Izquierdo, Diego

    2018-03-19

    To transculturally adapt the Spanish version of Pregnancy Physical Activity Questionnaire (PPAQ) analyzing its psychometric properties. The PPAQ was transculturally adapted into Spanish. Test-retest reliability was evaluated in a subsample of 109 pregnant women. The validity was evaluated in a sample of 208 pregnant women who answered the questionnaire and wore the multi-sensor monitor for 7 valid days. The reliability (intraclass correlation coefficient), concordance (concordance correlation coefficient), correlation (Pearson correlation coefficient), agreement (Bland-Altman plots) and relative activity levels (Jonckheere-Terpstra test) between both administrations and methods were examined. Intraclass correlation coefficients between both administrations were good for all categories except transportation. A low but significant correlation was found for total activity (light and above) whereas no correlation was found for other intensities between both methods. Relative activity levels analysis showed a significant linear trend for increased total activity between both methods. Spanish version of PPAQ is a brief and easily interpretable questionnaire with good reliability and ability to rank individuals, and poor validity compared with multi-sensor monitor. The use of PPAQ provides information of pregnancy-specific activities in order to establish physical activity levels of pregnant women and adapt health promotion interventions. Copyright © 2018 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Diagnosing cysts with correlation coefficient images from 2-dimensional freehand elastography.

    PubMed

    Booi, Rebecca C; Carson, Paul L; O'Donnell, Matthew; Richards, Michael S; Rubin, Jonathan M

    2007-09-01

    We compared the diagnostic potential of using correlation coefficient images versus elastograms from 2-dimensional (2D) freehand elastography to characterize breast cysts. In this preliminary study, which was approved by the Institutional Review Board and compliant with the Health Insurance Portability and Accountability Act, we imaged 4 consecutive human subjects (4 cysts, 1 biopsy-verified benign breast parenchyma) with freehand 2D elastography. Data were processed offline with conventional 2D phase-sensitive speckle-tracking algorithms. The correlation coefficient in the cyst and surrounding tissue was calculated, and appearances of the cysts in the correlation coefficient images and elastograms were compared. The correlation coefficient in the cysts was considerably lower (14%-37%) than in the surrounding tissue because of the lack of sufficient speckle in the cysts, as well as the prominence of random noise, reverberations, and clutter, which decorrelated quickly. Thus, the cysts were visible in all correlation coefficient images. In contrast, the elastograms associated with these cysts each had different elastographic patterns. The solid mass in this study did not have the same high decorrelation rate as the cysts, having a correlation coefficient only 2.1% lower than that of surrounding tissue. Correlation coefficient images may produce a more direct, reliable, and consistent method for characterizing cysts than elastograms.

  18. Dynamics analysis of SIR epidemic model with correlation coefficients and clustering coefficient in networks.

    PubMed

    Zhang, Juping; Yang, Chan; Jin, Zhen; Li, Jia

    2018-07-14

    In this paper, the correlation coefficients between nodes in states are used as dynamic variables, and we construct SIR epidemic dynamic models with correlation coefficients by using the pair approximation method in static networks and dynamic networks, respectively. Considering the clustering coefficient of the network, we analytically investigate the existence and the local asymptotic stability of each equilibrium of these models and derive threshold values for the prevalence of diseases. Additionally, we obtain two equivalent epidemic thresholds in dynamic networks, which are compared with the results of the mean field equations. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Hadamard multimode optical imaging transceiver

    DOEpatents

    Cooke, Bradly J; Guenther, David C; Tiee, Joe J; Kellum, Mervyn J; Olivas, Nicholas L; Weisse-Bernstein, Nina R; Judd, Stephen L; Braun, Thomas R

    2012-10-30

    Disclosed is a method and system for simultaneously acquiring and producing results for multiple image modes using a common sensor without optical filtering, scanning, or other moving parts. The system and method utilize the Walsh-Hadamard correlation detection process (e.g., functions/matrix) to provide an all-binary structure that permits seamless bridging between analog and digital domains. An embodiment may capture an incoming optical signal at an optical aperture, convert the optical signal to an electrical signal, pass the electrical signal through a Low-Noise Amplifier (LNA) to create an LNA signal, pass the LNA signal through one or more correlators where each correlator has a corresponding Walsh-Hadamard (WH) binary basis function, calculate a correlation output coefficient for each correlator as a function of the corresponding WH binary basis function in accordance with Walsh-Hadamard mathematical principles, digitize each of the correlation output coefficient by passing each correlation output coefficient through an Analog-to-Digital Converter (ADC), and performing image mode processing on the digitized correlation output coefficients as desired to produce one or more image modes. Some, but not all, potential image modes include: multi-channel access, temporal, range, three-dimensional, and synthetic aperture.

  20. An efficient sensitivity analysis method for modified geometry of Macpherson suspension based on Pearson correlation coefficient

    NASA Astrophysics Data System (ADS)

    Shojaeefard, Mohammad Hasan; Khalkhali, Abolfazl; Yarmohammadisatri, Sadegh

    2017-06-01

    The main purpose of this paper is to propose a new method for designing Macpherson suspension, based on the Sobol indices in terms of Pearson correlation which determines the importance of each member on the behaviour of vehicle suspension. The formulation of dynamic analysis of Macpherson suspension system is developed using the suspension members as the modified links in order to achieve the desired kinematic behaviour. The mechanical system is replaced with an equivalent constrained links and then kinematic laws are utilised to obtain a new modified geometry of Macpherson suspension. The equivalent mechanism of Macpherson suspension increased the speed of analysis and reduced its complexity. The ADAMS/CAR software is utilised to simulate a full vehicle, Renault Logan car, in order to analyse the accuracy of modified geometry model. An experimental 4-poster test rig is considered for validating both ADAMS/CAR simulation and analytical geometry model. Pearson correlation coefficient is applied to analyse the sensitivity of each suspension member according to vehicle objective functions such as sprung mass acceleration, etc. Besides this matter, the estimation of Pearson correlation coefficient between variables is analysed in this method. It is understood that the Pearson correlation coefficient is an efficient method for analysing the vehicle suspension which leads to a better design of Macpherson suspension system.

  1. Semi-quantitative spectrographic analysis and rank correlation in geochemistry

    USGS Publications Warehouse

    Flanagan, F.J.

    1957-01-01

    The rank correlation coefficient, rs, which involves less computation than the product-moment correlation coefficient, r, can be used to indicate the degree of relationship between two elements. The method is applicable in situations where the assumptions underlying normal distribution correlation theory may not be satisfied. Semi-quantitative spectrographic analyses which are reported as grouped or partly ranked data can be used to calculate rank correlations between elements. ?? 1957.

  2. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography.

    PubMed

    Stuberg, W A; Colerick, V L; Blanke, D J; Bruce, W

    1988-08-01

    The purpose of this study was to compare a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography in a gait analysis laboratory. Ten children with a diagnosis of cerebral palsy (means age = 8.8 +/- 2.7 years) and 9 healthy children (means age = 8.9 +/- 2.4 years) participated in the study. Stride length, walking velocity, and goniometric measurements of the hip, knee, and ankle were recorded using the two gait analysis methods. A multivariate analysis of variance was used to determine significant differences between the data collected using the two methods. Pearson product-moment correlation coefficients were determined to examine the relationship between the measurements recorded by the two methods. The consistency of performance of the subjects during walking was examined by intraclass correlation coefficients. No significant differences were found between the methods for the variables studied. Pearson product-moment correlation coefficients ranged from .79 to .95, and intraclass coefficients ranged from .89 to .97. The clinical gait analysis method was found to be a valid tool in comparison with 16-mm cinematography for the variables that were studied.

  3. High-resolution correlation

    NASA Astrophysics Data System (ADS)

    Nelson, D. J.

    2007-09-01

    In the basic correlation process a sequence of time-lag-indexed correlation coefficients are computed as the inner or dot product of segments of two signals. The time-lag(s) for which the magnitude of the correlation coefficient sequence is maximized is the estimated relative time delay of the two signals. For discrete sampled signals, the delay estimated in this manner is quantized with the same relative accuracy as the clock used in sampling the signals. In addition, the correlation coefficients are real if the input signals are real. There have been many methods proposed to estimate signal delay to more accuracy than the sample interval of the digitizer clock, with some success. These methods include interpolation of the correlation coefficients, estimation of the signal delay from the group delay function, and beam forming techniques, such as the MUSIC algorithm. For spectral estimation, techniques based on phase differentiation have been popular, but these techniques have apparently not been applied to the correlation problem . We propose a phase based delay estimation method (PBDEM) based on the phase of the correlation function that provides a significant improvement of the accuracy of time delay estimation. In the process, the standard correlation function is first calculated. A time lag error function is then calculated from the correlation phase and is used to interpolate the correlation function. The signal delay is shown to be accurately estimated as the zero crossing of the correlation phase near the index of the peak correlation magnitude. This process is nearly as fast as the conventional correlation function on which it is based. For real valued signals, a simple modification is provided, which results in the same correlation accuracy as is obtained for complex valued signals.

  4. Evaluation of estimation methods for organic carbon normalized sorption coefficients

    USGS Publications Warehouse

    Baker, James R.; Mihelcic, James R.; Luehrs, Dean C.; Hickey, James P.

    1997-01-01

    A critically evaluated set of 94 soil water partition coefficients normalized to soil organic carbon content (Koc) is presented for 11 classes of organic chemicals. This data set is used to develop and evaluate Koc estimation methods using three different descriptors. The three types of descriptors used in predicting Koc were octanol/water partition coefficient (Kow), molecular connectivity (mXt) and linear solvation energy relationships (LSERs). The best results were obtained estimating Koc from Kow, though a slight improvement in the correlation coefficient was obtained by using a two-parameter regression with Kow and the third order difference term from mXt. Molecular connectivity correlations seemed to be best suited for use with specific chemical classes. The LSER provided a better fit than mXt but not as good as the correlation with Koc. The correlation to predict Koc from Kow was developed for 72 chemicals; log Koc = 0.903* log Kow + 0.094. This correlation accounts for 91% of the variability in the data for chemicals with log Kow ranging from 1.7 to 7.0. The expression to determine the 95% confidence interval on the estimated Koc is provided along with an example for two chemicals of different hydrophobicity showing the confidence interval of the retardation factor determined from the estimated Koc. The data showed that Koc is not likely to be applicable for chemicals with log Kow < 1.7. Finally, the Koc correlation developed using Kow as a descriptor was compared with three nonclass-specific correlations and two 'commonly used' class-specific correlations to determine which method(s) are most suitable.

  5. The Delicate Analysis of Short-Term Load Forecasting

    NASA Astrophysics Data System (ADS)

    Song, Changwei; Zheng, Yuan

    2017-05-01

    This paper proposes a new method for short-term load forecasting based on the similar day method, correlation coefficient and Fast Fourier Transform (FFT) to achieve the precision analysis of load variation from three aspects (typical day, correlation coefficient, spectral analysis) and three dimensions (time dimension, industry dimensions, the main factors influencing the load characteristic such as national policies, regional economic, holidays, electricity and so on). First, the branch algorithm one-class-SVM is adopted to selection the typical day. Second, correlation coefficient method is used to obtain the direction and strength of the linear relationship between two random variables, which can reflect the influence caused by the customer macro policy and the scale of production to the electricity price. Third, Fourier transform residual error correction model is proposed to reflect the nature of load extracting from the residual error. Finally, simulation result indicates the validity and engineering practicability of the proposed method.

  6. [Correlation coefficient-based principle and method for the classification of jump degree in hydrological time series].

    PubMed

    Wu, Zi Yi; Xie, Ping; Sang, Yan Fang; Gu, Hai Ting

    2018-04-01

    The phenomenon of jump is one of the importantly external forms of hydrological variabi-lity under environmental changes, representing the adaption of hydrological nonlinear systems to the influence of external disturbances. Presently, the related studies mainly focus on the methods for identifying the jump positions and jump times in hydrological time series. In contrast, few studies have focused on the quantitative description and classification of jump degree in hydrological time series, which make it difficult to understand the environmental changes and evaluate its potential impacts. Here, we proposed a theatrically reliable and easy-to-apply method for the classification of jump degree in hydrological time series, using the correlation coefficient as a basic index. The statistical tests verified the accuracy, reasonability, and applicability of this method. The relationship between the correlation coefficient and the jump degree of series were described using mathematical equation by derivation. After that, several thresholds of correlation coefficients under different statistical significance levels were chosen, based on which the jump degree could be classified into five levels: no, weak, moderate, strong and very strong. Finally, our method was applied to five diffe-rent observed hydrological time series, with diverse geographic and hydrological conditions in China. The results of the classification of jump degrees in those series were closely accorded with their physically hydrological mechanisms, indicating the practicability of our method.

  7. Thermal expansion coefficient determination of polylactic acid using digital image correlation

    NASA Astrophysics Data System (ADS)

    Botean, Adrian-Ioan

    2018-02-01

    This paper aims determining the linear thermal expansion coefficient (CTE) of polylactic acid (PLA) using an optical method for measuring deformations called digital image correlation method (DIC). Because PLA is often used in making many pieces with 3D printing technology, it is opportune to know this coefficient to obtain a higher degree of precision in the construction of parts and to monitor deformations when these parts are subjected to a thermal gradient. Are used two PLA discs with 20 and 40% degree of filling. In parallel with this approach was determined the linear thermal expansion coefficient (CTE) for the copper cylinder on the surface of which are placed the two discs of PLA.

  8. Estimating Seven Coefficients of Pairwise Relatedness Using Population-Genomic Data

    PubMed Central

    Ackerman, Matthew S.; Johri, Parul; Spitze, Ken; Xu, Sen; Doak, Thomas G.; Young, Kimberly; Lynch, Michael

    2017-01-01

    Population structure can be described by genotypic-correlation coefficients between groups of individuals, the most basic of which are the pairwise relatedness coefficients between any two individuals. There are nine pairwise relatedness coefficients in the most general model, and we show that these can be reduced to seven coefficients for biallelic loci. Although all nine coefficients can be estimated from pedigrees, six coefficients have been beyond empirical reach. We provide a numerical optimization procedure that estimates all seven reduced coefficients from population-genomic data. Simulations show that the procedure is nearly unbiased, even at 3× coverage, and errors in five of the seven coefficients are statistically uncorrelated. The remaining two coefficients have a negative correlation of errors, but their sum provides an unbiased assessment of the overall correlation of heterozygosity between two individuals. Application of these new methods to four populations of the freshwater crustacean Daphnia pulex reveal the occurrence of half siblings in our samples, as well as a number of identical individuals that are likely obligately asexual clone mates. Statistically significant negative estimates of these pairwise relatedness coefficients, including inbreeding coefficients that were typically negative, underscore the difficulties that arise when interpreting genotypic correlations as estimations of the probability that alleles are identical by descent. PMID:28341647

  9. Correlation Between the Field Line and Particle Diffusion Coefficients in the Stochastic Fields of a Tokamak

    NASA Astrophysics Data System (ADS)

    Calvin, Mark; Punjabi, Alkesh

    1996-11-01

    We use the method of quasi-magnetic surfaces to calculate the correlation between the field line and particle diffusion coefficients. The magnetic topology of a tokamak is perturbed by a spectrum of neighboring resonant resistive modes. The Hamiltonian equations of motion for the field line are integrated numerically. Poincare plots of the quasi-magnetic surfaces are generated initially and after the field line has traversed a considerable distance. From the areas of the quasi-magnetic surfaces and the field line distance, we estimate the field line diffusion coefficient. We start plasma particles on the initial quasi-surface, and calculate the particle diffusion coefficient from our Monte Carlo method (Punjabi A., Boozer A., Lam M., Kim H. and Burke K., J. Plasma Phys.), 44, 405 (1990). We then estimate the correlation between the particle and field diffusion as the strength of the resistive modes is varied.

  10. 40 CFR Figure C-4 to Subpart C of... - Illustration of the Minimum Limits for Correlation Coefficient for PM 2.5 and PM 10-2,5 Class II...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Illustration of the Minimum Limits for Correlation Coefficient for PM 2.5 and PM 10-2,5 Class II and III Methods C Figure C-4 to Subpart C of Part 53... Methods and Reference Methods Pt. 53, Subpt. C, Fig. C-4 Figure C-4 to Subpart C of Part 53—Illustration...

  11. 40 CFR Figure C-4 to Subpart C of... - Illustration of the Minimum Limits for Correlation Coefficient for PM 2.5 and PM 10-2.5 Class II...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Illustration of the Minimum Limits for Correlation Coefficient for PM 2.5 and PM 10-2.5 Class II and III Methods C Figure C-4 to Subpart C of Part 53... Methods and Reference Methods Pt. 53, Subpt. C, Fig. C-4 Figure C-4 to Subpart C of Part 53—Illustration...

  12. Inferential Procedures for Correlation Coefficients Corrected for Attenuation.

    ERIC Educational Resources Information Center

    Hakstian, A. Ralph; And Others

    1988-01-01

    A model and computation procedure based on classical test score theory are presented for determination of a correlation coefficient corrected for attenuation due to unreliability. Delta and Monte Carlo method applications are discussed. A power analysis revealed no serious loss in efficiency resulting from correction for attentuation. (TJH)

  13. Correlation tests of the engine performance parameter by using the detrended cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Dong, Keqiang; Gao, You; Jing, Liming

    2015-02-01

    The presence of cross-correlation in complex systems has long been noted and studied in a broad range of physical applications. We here focus on an aero-engine system as an example of a complex system. By applying the detrended cross-correlation (DCCA) coefficient method to aero-engine time series, we investigate the effects of the data length and the time scale on the detrended cross-correlation coefficients ρ DCCA ( T, s). We then show, for a twin-engine aircraft, that the engine fuel flow time series derived from the left engine and the right engine exhibit much stronger cross-correlations than the engine exhaust-gas temperature series derived from the left engine and the right engine do.

  14. Comparison of RNFL thickness and RPE-normalized RNFL attenuation coefficient for glaucoma diagnosis

    NASA Astrophysics Data System (ADS)

    Vermeer, K. A.; van der Schoot, J.; Lemij, H. G.; de Boer, J. F.

    2013-03-01

    Recently, a method to determine the retinal nerve fiber layer (RNFL) attenuation coefficient, based on normalization on the retinal pigment epithelium, was introduced. In contrast to conventional RNFL thickness measures, this novel measure represents a scattering property of the RNFL tissue. In this paper, we compare the RNFL thickness and the RNFL attenuation coefficient on 10 normal and 8 glaucomatous eyes by analyzing the correlation coefficient and the receiver operator curves (ROCs). The thickness and attenuation coefficient showed moderate correlation (r=0.82). Smaller correlation coefficients were found within normal (r=0.55) and glaucomatous (r=0.48) eyes. The full separation between normal and glaucomatous eyes based on the RNFL attenuation coefficient yielded an area under the ROC (AROC) of 1.0. The AROC for the RNFL thickness was 0.9875. No statistically significant difference between the two measures was found by comparing the AROC. RNFL attenuation coefficients may thus replace current RNFL thickness measurements or be combined with it to improve glaucoma diagnosis.

  15. Different hip and knee priority score systems: are they good for the same thing?

    PubMed

    Escobar, Antonio; Quintana, Jose Maria; Espallargues, Mireia; Allepuz, Alejandro; Ibañez, Berta

    2010-10-01

    The aim of the present study was to compare two priority tools used for joint replacement for patients on waiting lists, which use two different methods. Two prioritization tools developed and validated by different methodologies were used on the same cohort of patients. The first, an IRYSS hip and knee priority score (IHKPS) developed by RAND method, was applied while patients were on the waiting list. The other, a Catalonia hip-knee priority score (CHKPS) developed by conjoint analysis, was adapted and applied retrospectively. In addition, all patients fulfilled pre-intervention the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Correlation between them was studied by Pearson correlation coefficient (r). Agreement was analysed by means of intra-class correlation coefficient (ICC), Kendall coefficient and Cohern kappa. The relationship between IHKPS, CHKPS and baseline WOMAC scores by r coefficient was studied. The sample consisted of 774 consecutive patients. Pearson correlation coefficient between IHKPS and CHKPS was 0.79. The agreement study showed that ICC was 0.74, Kendall coefficient 0.86 and kappa 0.66. Finally, correlation between CHKPS and baseline WOMAC ranged from 0.43 to 0.64. The results according to the relationship between IHKPS and WOMAC ranged from 0.50 to 0.74. Results support the hypothesis that if the final objective of the prioritization tools is to organize and sort patients on the waiting list, although they use different methodologies, the results are similar. © 2010 Blackwell Publishing Ltd.

  16. Correlation and prediction of gaseous diffusion coefficients.

    NASA Technical Reports Server (NTRS)

    Marrero, T. R.; Mason, E. A.

    1973-01-01

    A new correlation method for binary gaseous diffusion coefficients from very low temperatures to 10,000 K is proposed based on an extended principle of corresponding states, and having greater range and accuracy than previous correlations. There are two correlation parameters that are related to other physical quantities and that are predictable in the absence of diffusion measurements. Quantum effects and composition dependence are included, but high-pressure effects are not. The results are directly applicable to multicomponent mixtures.

  17. A comparison of confidence interval methods for the concordance correlation coefficient and intraclass correlation coefficient with small number of raters.

    PubMed

    Feng, Dai; Svetnik, Vladimir; Coimbra, Alexandre; Baumgartner, Richard

    2014-01-01

    The intraclass correlation coefficient (ICC) with fixed raters or, equivalently, the concordance correlation coefficient (CCC) for continuous outcomes is a widely accepted aggregate index of agreement in settings with small number of raters. Quantifying the precision of the CCC by constructing its confidence interval (CI) is important in early drug development applications, in particular in qualification of biomarker platforms. In recent years, there have been several new methods proposed for construction of CIs for the CCC, but their comprehensive comparison has not been attempted. The methods consisted of the delta method and jackknifing with and without Fisher's Z-transformation, respectively, and Bayesian methods with vague priors. In this study, we carried out a simulation study, with data simulated from multivariate normal as well as heavier tailed distribution (t-distribution with 5 degrees of freedom), to compare the state-of-the-art methods for assigning CI to the CCC. When the data are normally distributed, the jackknifing with Fisher's Z-transformation (JZ) tended to provide superior coverage and the difference between it and the closest competitor, the Bayesian method with the Jeffreys prior was in general minimal. For the nonnormal data, the jackknife methods, especially the JZ method, provided the coverage probabilities closest to the nominal in contrast to the others which yielded overly liberal coverage. Approaches based upon the delta method and Bayesian method with conjugate prior generally provided slightly narrower intervals and larger lower bounds than others, though this was offset by their poor coverage. Finally, we illustrated the utility of the CIs for the CCC in an example of a wake after sleep onset (WASO) biomarker, which is frequently used in clinical sleep studies of drugs for treatment of insomnia.

  18. Sector Identification in a Set of Stock Return Time Series Traded at the London Stock Exchange

    NASA Astrophysics Data System (ADS)

    Coronnello, C.; Tumminello, M.; Lillo, F.; Micciche, S.; Mantegna, R. N.

    2005-09-01

    We compare some methods recently used in the literature to detect the existence of a certain degree of common behavior of stock returns belonging to the same economic sector. Specifically, we discuss methods based on random matrix theory and hierarchical clustering techniques. We apply these methods to a portfolio of stocks traded at the London Stock Exchange. The investigated time series are recorded both at a daily time horizon and at a 5-minute time horizon. The correlation coefficient matrix is very different at different time horizons confirming that more structured correlation coefficient matrices are observed for long time horizons. All the considered methods are able to detect economic information and the presence of clusters characterized by the economic sector of stocks. However, different methods present a different degree of sensitivity with respect to different sectors. Our comparative analysis suggests that the application of just a single method could not be able to extract all the economic information present in the correlation coefficient matrix of a stock portfolio.

  19. [Tobacco quality analysis of industrial classification of different years using near-infrared (NIR) spectrum].

    PubMed

    Wang, Yi; Xiang, Ma; Wen, Ya-Dong; Yu, Chun-Xia; Wang, Luo-Ping; Zhao, Long-Lian; Li, Jun-Hui

    2012-11-01

    In this study, tobacco quality analysis of main Industrial classification of different years was carried out applying spectrum projection and correlation methods. The group of data was near-infrared (NIR) spectrum from Hongta Tobacco (Group) Co., Ltd. 5730 tobacco leaf Industrial classification samples from Yuxi in Yunnan province from 2007 to 2010 year were collected using near infrared spectroscopy, which from different parts and colors and all belong to tobacco varieties of HONGDA. The conclusion showed that, when the samples were divided to two part by the ratio of 2:1 randomly as analysis and verification sets in the same year, the verification set corresponded with the analysis set applying spectrum projection because their correlation coefficients were above 0.98. The correlation coefficients between two different years applying spectrum projection were above 0.97. The highest correlation coefficient was the one between 2008 and 2009 year and the lowest correlation coefficient was the one between 2007 and 2010 year. At the same time, The study discussed a method to get the quantitative similarity values of different industrial classification samples. The similarity and consistency values were instructive in combination and replacement of tobacco leaf blending.

  20. Image stitching and image reconstruction of intestines captured using radial imaging capsule endoscope

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Mang; Jeng, Wei-De; Wu, Yin-Yi; Dung, Lan-Rong; Wu, Hsien-Ming; Weng, Ping-Kuo; Huang, Ker-Jer; Chiu, Luan-Jiau

    2012-05-01

    This study investigates image processing using the radial imaging capsule endoscope (RICE) system. First, an experimental environment is established in which a simulated object has a shape that is similar to a cylinder, such that a triaxial platform can be used to push the RICE into the sample and capture radial images. Then four algorithms (mean absolute error, mean square error, Pearson correlation coefficient, and deformation processing) are used to stitch the images together. The Pearson correlation coefficient method is the most effective algorithm because it yields the highest peak signal-to-noise ratio, higher than 80.69 compared to the original image. Furthermore, a living animal experiment is carried out. Finally, the Pearson correlation coefficient method and vector deformation processing are used to stitch the images that were captured in the living animal experiment. This method is very attractive because unlike the other methods, in which two lenses are required to reconstruct the geometrical image, RICE uses only one lens and one mirror.

  1. Intraclass Correlation Coefficients in Hierarchical Designs: Evaluation Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko

    2011-01-01

    Interval estimation of intraclass correlation coefficients in hierarchical designs is discussed within a latent variable modeling framework. A method accomplishing this aim is outlined, which is applicable in two-level studies where participants (or generally lower-order units) are clustered within higher-order units. The procedure can also be…

  2. Simplified Radiographic Damage Index for Affected Joints in Chronic Gouty Arthritis

    PubMed Central

    2016-01-01

    The aim of this study was to develop and validate a new radiographic damage scoring method (DAmagE index of GoUt; DAEGU) in chronic gout using plain radiography. Two independent observers scored foot x-rays from 15 patients with chronic gout according to the DAEGU method and the modified Sharp/van der Heijde (SvdH) method. The 10 metatarsophalangeal (MTP) and 2 interphalangeal (IP) joints of the first toes of both feet were scored to assess the degrees of erosion and joint space narrowing (JSN). The intraobserver and interobserver reliabilities were analyzed by calculating the intraclass correlation coefficient (ICC) and minimal detectable change (MDC). The correlation between the DAEGU and SvdH methods was analyzed by calculating the Spearman's rho correlation coefficients and Kappa coefficients. The DAEGU method was found to be highly reproducible (0.945–0.987 for the intraobserver and 0.993–0.996 for the interobserver ICC values). The erosion, JSN, and total scores exhibited strong positive correlations between the DAEGU and SvdH methods and also within each method (r = 0.860–0.969, P < 0.001 for all parameters). The DAEGU and SvdH methods were in very good agreement as determined by Kappa coefficient analysis [0.732 (0.387–1.000) for erosion and 1.000 (1.000–1.000) for JSN]. In conclusion, this study revealed that DAEGU method was a reliable and feasible tool in the assessment of radiographic damage in chronic gout. The DAEGU method may provide a more easy assessment of structural damage in chronic gout in the real clinical practice. PMID:26955246

  3. Quantifying the range of cross-correlated fluctuations using a q- L dependent AHXA coefficient

    NASA Astrophysics Data System (ADS)

    Wang, Fang; Wang, Lin; Chen, Yuming

    2018-03-01

    Recently, based on analogous height cross-correlation analysis (AHXA), a cross-correlation coefficient ρ×(L) has been proposed to quantify the levels of cross-correlation on different temporal scales for bivariate series. A limitation of this coefficient is that it cannot capture the full information of cross-correlations on amplitude of fluctuations. In fact, it only detects the cross-correlation at a specific order fluctuation, which might neglect some important information inherited from other order fluctuations. To overcome this disadvantage, in this work, based on the scaling of the qth order covariance and time delay L, we define a two-parameter dependent cross-correlation coefficient ρq(L) to detect and quantify the range and level of cross-correlations. This new version of ρq(L) coefficient leads to the formation of a ρq(L) surface, which not only is able to quantify the level of cross-correlations, but also allows us to identify the range of fluctuation amplitudes that are correlated in two given signals. Applications to the classical ARFIMA models and the binomial multifractal series illustrate the feasibility of this new coefficient ρq(L) . In addition, a statistical test is proposed to quantify the existence of cross-correlations between two given series. Applying our method to the real life empirical data from the 1999-2000 California electricity market, we find that the California power crisis in 2000 destroys the cross-correlation between the price and the load series but does not affect the correlation of the load series during and before the crisis.

  4. Estimating a graphical intra-class correlation coefficient (GICC) using multivariate probit-linear mixed models.

    PubMed

    Yue, Chen; Chen, Shaojie; Sair, Haris I; Airan, Raag; Caffo, Brian S

    2015-09-01

    Data reproducibility is a critical issue in all scientific experiments. In this manuscript, the problem of quantifying the reproducibility of graphical measurements is considered. The image intra-class correlation coefficient (I2C2) is generalized and the graphical intra-class correlation coefficient (GICC) is proposed for such purpose. The concept for GICC is based on multivariate probit-linear mixed effect models. A Markov Chain Monte Carlo EM (mcm-cEM) algorithm is used for estimating the GICC. Simulation results with varied settings are demonstrated and our method is applied to the KIRBY21 test-retest dataset.

  5. 40 CFR Figure C-4 to Subpart C of... - Illustration of the Minimum Limits for Correlation Coefficient for PM2.5 and PM10−2.5 Class II...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Illustration of the Minimum Limits for Correlation Coefficient for PM2.5 and PM10â2.5 Class II and III Methods C Figure C-4 to Subpart C of Part 53... Methods and Reference Methods Pt. 53, Subpt. C, Fig. C-4 Figure C-4 to Subpart C of Part 53—Illustration...

  6. 40 CFR Figure C-4 to Subpart C of... - Illustration of the Minimum Limits for Correlation Coefficient for PM2.5 and PM10−2.5 Class II...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Illustration of the Minimum Limits for Correlation Coefficient for PM2.5 and PM10â2.5 Class II and III Methods C Figure C-4 to Subpart C of Part 53... Methods and Reference Methods Pt. 53, Subpt. C, Fig. C-4 Figure C-4 to Subpart C of Part 53—Illustration...

  7. 40 CFR Figure C-4 to Subpart C of... - Illustration of the Minimum Limits for Correlation Coefficient for PM2.5 and PM10−2.5 Class II...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Illustration of the Minimum Limits for Correlation Coefficient for PM2.5 and PM10â2.5 Class II and III Methods C Figure C-4 to Subpart C of Part 53... Methods and Reference Methods Pt. 53, Subpt. C, Fig. C-4 Figure C-4 to Subpart C of Part 53—Illustration...

  8. Body Adiposity Index Performance in Estimating Body Fat Percentage in Colombian College Students: Findings from the FUPRECOL-Adults Study.

    PubMed

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio

    2017-01-17

    Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5)) -18 ) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin's concordance correlation coefficient, linear regression, Bland-Altman's agreement analysis, concordance correlation coefficient ( ρc ) and the coefficient of determination ( R ²) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R ² = 0.384, p < 0.001. A paired-sample t -test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = -6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin's concordance correlation coefficient was poor ( ρc = 0.014, 95% CI = -0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels.

  9. [Examination of diagnosis procedure combination survey data that influence function evaluation coefficient II].

    PubMed

    Nakajima, Hisato; Yano, Kouya; Nagasawa, Kaoko; Kobayashi, Eiji; Yokota, Kuninobu

    2015-01-01

    On the basis of Diagnosis Procedure Combination (DPC) survey data, the factors that increase the value of function evaluation coefficient II were considered. A total of 1,505 hospitals were divided into groups I, II, and III, and the following items were considered. 1. Significant differences in function evaluation coefficient II and DPC survey data. 2. Examination of using the Mahalanobis-Taguchi (MT) method. 3. Correlation between function evaluation coefficient II and each DPC survey data item. 1. Function evaluation coefficient II was highest in group II. Group I hospitals showed the highest bed capacity, and numbers of hospitalization days, operations, chemotherapies, radiotherapies and general anesthesia procedures. 2. Using the MT method, we found that the number of ambulance conveyances was effective factor in group I hospitals, the number of general anesthesia procedures was effective factor in group II hospitals, and the bed capacity was effective factor in group III hospitals. 3. In group I hospitals, function evaluation coefficient II significantly correlated to the numbers of ambulance conveyances and chemotherapies. In group II hospitals, function evaluation coefficient II significantly correlated to bed capacity, the numbers of ambulance conveyances, hospitalization days, operations, general anesthesia procedures, and mean hospitalization days. In group III hospitals, function evaluation coefficient II significantly correlated to all items. The factors that improve the value of function evaluation coefficient II were the increases in the numbers of ambulance conveyances, chemotherapies and radiotherapies in group I hospitals, increases in the numbers of hospitalization days, operations, ambulance conveyances and general anesthesia procedures in group II hospitals, and increases in the numbers of hospitalization days, operations and ambulance conveyances. These results indicate that the profit of a hospital will increase, which will lead to medical services of good quality.

  10. Validation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obese Colombian adults.

    PubMed

    Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; González-Jiménez, Emilio; Triana-Reina, Hector Reynaldo; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline

    2018-01-01

    To verify the validity of multi-frequency bioelectrical impedance analysis (mBCA) for predicting body fat percentage (BF%) in overweight/obese adults using dual-energy X-ray absorptiometry (DXA) as the reference method. Forty-eight adults participated (54% women, mean age = 41.0 ± 7.3 years old). The Pearson's correlation coefficient was used to evaluate the correlation between BIA and BF% assessed by DXA. The concordance between BF% measured by both methods was obtained with Lin's concordance correlation coefficient and Bland-Altman difference plots. Measures of BF% were estimated as 39.0 (SD = 6.1) and 38.3 (SD = 6.5) using DXA and mBCA, respectively. The Pearson's correlation coefficient reflected a strong correlation (r =.921, P = .001). The paired t-test showed a significant mean difference between these methods for obese men BF% of -0.6 [(SD 1.95; 95% CI = -4.0 to 3.0), P =.037]. Overall, the bias of the mBCA was -0.6 [(SD 2.2; 95% CI = -5.0 to 3.7), P =.041], which indicated that the mBCA method significantly underestimated BF% in comparison to the reference method. Finally, in both genders, Lin's concordance correlation coefficient showed a strong agreement. More specifically the DXA value was ρc = 0.943 (95% CI = 0.775 to 0.950) and the mBCA value was ρc = 0.948 (95% CI = 0.778 to 0.978). Our analysis showed a strong agreement between the two methods as reflected in the range of BF%. These results show that mBCA and DXA are comparable methods for measuring body composition with higher body fat percentages. However, due to broad limits of agreement, we can only recommend mBCA for groups of populations. © 2017 Wiley Periodicals, Inc.

  11. Reliability and validity of a quantitative color scale to evaluate masticatory performance using color-changeable chewing gum.

    PubMed

    Hama, Yohei; Kanazawa, Manabu; Minakuchi, Shunsuke; Uchida, Tatsuro; Sasaki, Yoshiyuki

    2014-03-19

    In the present study, we developed a novel color scale for visual assessment, conforming to theoretical color changes of a gum, to evaluate masticatoryperformance; moreover, we investigated the reliability and validity of this evaluation method using the color scale. Ten participants (aged 26.30 years) with natural dentition chewed the gum at several chewing strokes. Changes in color were measured using a colorimeter, and then, linearregression expressions that represented changes in gum color were derived. The color scale was developed using these regression expressions. Thirty-two chewed gums were evaluated using colorimeter and were assessed three times using the color scale by six dentists aged 25.27 (mean, 25.8) years, six preclinical dental students aged 21.23 (mean, 22.2) years, and six elderly individuals aged 68.84 (mean, 74.0) years. The intrarater and interrater reliability of evaluations was assessed using intraclass correlation coefficients. Validity of the method compared with a colorimeter was assessed using Spearman's rank correlation coefficient. All intraclass correlation coefficients were > 0.90, and Spearman's rank-correlation coefficients were > 0.95 in all groups. These results indicated that the evaluation method of the color-changeable chewing gum using the newly developed color scale is reliable and valid.

  12. HARBO, a simple computer-aided observation method for recording work postures.

    PubMed

    Wiktorin, C; Mortimer, M; Ekenvall, L; Kilbom, A; Hjelm, E W

    1995-12-01

    The aim of the study was to present an observation method focusing on the positions of the hands relative to the body and to evaluate whether this simple observation technique gives a reliable estimate of the total time spent in each of five work postures during one workday. In the first part of the study the interobserver reliability of the observation method was tested with eight blue-collar workers. In the second part the observed time spent with work above the shoulder level was tested in relation to an upper-arm position analyzer, and observed time spent in work below knuckle level was tested in relation to a trunk flexion analyzer, both with 72 blue-collar workers. The interobserver reliability for full-day registrations was high. The intraclass correlation coefficients ranged from 0.99 to 1.00. The observed duration of work with hands above shoulder level correlated well with the measured duration of pronounced arm elevation (> 75 degrees). The product moment correlation coefficient was 0.97. The observed duration of work with hands below knuckle level correlated well with the measured duration of pronounced trunk flexion angles (> 40 degrees). The product moment correlation coefficient was 0.98. The present observation method, designed to make postural observations continuously for several hours, is easy to learn and seems reliable.

  13. Scale-Free Nonparametric Factor Analysis: A User-Friendly Introduction with Concrete Heuristic Examples.

    ERIC Educational Resources Information Center

    Mittag, Kathleen Cage

    Most researchers using factor analysis extract factors from a matrix of Pearson product-moment correlation coefficients. A method is presented for extracting factors in a non-parametric way, by extracting factors from a matrix of Spearman rho (rank correlation) coefficients. It is possible to factor analyze a matrix of association such that…

  14. Sample Size Calculation for Estimating or Testing a Nonzero Squared Multiple Correlation Coefficient

    ERIC Educational Resources Information Center

    Krishnamoorthy, K.; Xia, Yanping

    2008-01-01

    The problems of hypothesis testing and interval estimation of the squared multiple correlation coefficient of a multivariate normal distribution are considered. It is shown that available one-sided tests are uniformly most powerful, and the one-sided confidence intervals are uniformly most accurate. An exact method of calculating sample size to…

  15. [Surface electromyography signal classification using gray system theory].

    PubMed

    Xie, Hongbo; Ma, Congbin; Wang, Zhizhong; Huang, Hai

    2004-12-01

    A new method based on gray correlation was introduced to improve the identification rate in artificial limb. The electromyography (EMG) signal was first transformed into time-frequency domain by wavelet transform. Singular value decomposition (SVD) was then used to extract feature vector from the wavelet coefficient for pattern recognition. The decision was made according to the maximum gray correlation coefficient. Compared with neural network recognition, this robust method has an almost equivalent recognition rate but much lower computation costs and less training samples.

  16. Preliminary study of radioactive limonite localities in Colorado, Utah, and Wyoming

    USGS Publications Warehouse

    Lovering, T.G.; Beroni, E.P.

    1956-01-01

    Nine radioactive limonite localities of different types were sampled during the spring and fall of 1953 in an effort to establish criteria for differentiating limonite outcrops associated with uranium or thorium deposits from limonite outcrops not associated with such deposits. The samples were analyzed for uranium and thorium by standard chemical methods, for equivalent uranium by the radiometric method, and for a number of common metals by semiquantitative geochemical methods. Correlation coefficients were then calculated for each of the metals with respect to equivalent uranium, and to uranium where present, for all of the samples from each locality. The correlation coefficients may indicate a significant association between uranium or thorium and certain metals. Occurrences of specific that are interpreted as significant very considerably for different uranium localities but are more consistent for the thorium localities. Samples taken from radioactive outcrops in the vicinity of uranium or thorium deposits can be quickly analyzed by geochemical methods for various elements. Correlation coefficients can then be determined for the various elements with respect to uranium or thorium; if any significant correlations are obtained, the elements showing such correlation may be indicators of uranium or thorium. Soil samples of covered areas in the vicinity of the radioactive outcrop may then be analyzed for the indicator elements and any resulting anomalies used as a guide for prospecting where the depth of overburden is too great to allow the use of radiation-detecting instruments. Correlation coefficients of the associated indicator elements, used in conjunction with petrographic evidence, may also be useful in interpreting the origin and paragenesis of radioactive deposits. Changes in color of limonite stains on the outcrop may also be a useful guide to ore in some areas.

  17. Reconstructing networks from dynamics with correlated noise

    NASA Astrophysics Data System (ADS)

    Tam, H. C.; Ching, Emily S. C.; Lai, Pik-Yin

    2018-07-01

    Reconstructing the structure of complex networks from measurements of the nodes is a challenge in many branches of science. External influences are always present and act as a noise to the networks of interest. In this paper, we present a method for reconstructing networks from measured dynamics of the nodes subjected to correlated noise that cannot be approximated by a white noise. This method can reconstruct the links of both bidirectional and directed networks, the correlation time and strength of the noise, and also the relative coupling strength of the links when the coupling functions have certain properties. Our method is built upon theoretical relations between network structure and measurable quantities from the dynamics that we have derived for systems that have fixed point dynamics in the noise-free limit. Using these theoretical results, we can further explain the shortcomings of two common practices of inferring links for bidirectional networks using the Pearson correlation coefficient and the partial correlation coefficient.

  18. Research and Development of Methods for Estimating Physicochemical Properties of Organic Compounds of Environmental Concern

    DTIC Science & Technology

    1979-02-01

    coefficient (at equilibrium) when hysteresis is apparent. 6. Coefficient n in Freundlich equation for 1/n soil or sediment adsorption isotherms ýX - KC . 7...Biodegradation Chemical structures cal clasaes (e.g., Diffusion Correlations phenols). General Diffusion coefficients Equations terms for organic...OF THE FATE AND TRANSPORT OF ORGANIC CHEMICALS Adsorption coefficients: K, n* from Freundlich equation + Desorption coefficients: K’*, n’* from

  19. Cross-Correlations and Structures of Aero-Engine Gas Path System Based on DCCA Coefficient and Rooted Tree

    NASA Astrophysics Data System (ADS)

    Dong, Keqiang; Fan, Jie; Gao, You

    2015-12-01

    Identifying the mutual interaction is a crucial problem that facilitates the understanding of emerging structures in complex system. We here focus on aero-engine dynamic as an example of complex system. By applying the detrended cross-correlation analysis (DCCA) coefficient method to aero-engine gas path system, we find that the low-spool rotor speed (N1) and high-spool rotor speed (N2) fluctuation series exhibit cross-correlation characteristic. Further, we employ detrended cross-correlation coefficient matrix and rooted tree to investigate the mutual interactions of other gas path variables. The results can infer that the exhaust gas temperature (EGT), N1, N2, fuel flow (WF) and engine pressure ratio (EPR) are main gas path parameters.

  20. aCORN: An experiment to measure the electron-antineutrino correlation coefficient in free neutron decay

    DOE PAGES

    Collett, B.; Bateman, F.; Bauder, W. K.; ...

    2017-08-01

    Here, we describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. This apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. We present details of the method, apparatus, detectors, data acquisition, and data reduction scheme, along with a discussion of the important systematic effects.

  1. aCORN: An experiment to measure the electron-antineutrino correlation coefficient in free neutron decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collett, B.; Bateman, F.; Bauder, W. K.

    Here, we describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. This apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. We present details of the method, apparatus, detectors, data acquisition, and data reduction scheme, along with a discussion of the important systematic effects.

  2. aCORN: An experiment to measure the electron-antineutrino correlation coefficient in free neutron decay.

    PubMed

    Collett, B; Bateman, F; Bauder, W K; Byrne, J; Byron, W A; Chen, W; Darius, G; DeAngelis, C; Dewey, M S; Gentile, T R; Hassan, M T; Jones, G L; Komives, A; Laptev, A; Mendenhall, M P; Nico, J S; Noid, G; Park, H; Stephenson, E J; Stern, I; Stockton, K J S; Trull, C; Wietfeldt, F E; Yerozolimsky, B G

    2017-08-01

    We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.

  3. Classical Wigner method with an effective quantum force: application to reaction rates.

    PubMed

    Poulsen, Jens Aage; Li, Huaqing; Nyman, Gunnar

    2009-07-14

    We construct an effective "quantum force" to be used in the classical molecular dynamics part of the classical Wigner method when determining correlation functions. The quantum force is obtained by estimating the most important short time separation of the Feynman paths that enter into the expression for the correlation function. The evaluation of the force is then as easy as classical potential energy evaluations. The ideas are tested on three reaction rate problems. The resulting transmission coefficients are in much better agreement with accurate results than transmission coefficients from the ordinary classical Wigner method.

  4. Band selection method based on spectrum difference in targets of interest in hyperspectral imagery

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaohan; Yang, Guang; Yang, Yongbo; Huang, Junhua

    2016-10-01

    While hyperspectral data shares rich spectrum information, it has numbers of bands with high correlation coefficients, causing great data redundancy. A reasonable band selection is important for subsequent processing. Bands with large amount of information and low correlation should be selected. On this basis, according to the needs of target detection applications, the spectral characteristics of the objects of interest are taken into consideration in this paper, and a new method based on spectrum difference is proposed. Firstly, according to the spectrum differences of targets of interest, a difference matrix which represents the different spectral reflectance of different targets in different bands is structured. By setting a threshold, the bands satisfying the conditions would be left, constituting a subset of bands. Then, the correlation coefficients between bands are calculated and correlation matrix is given. According to the size of the correlation coefficient, the bands can be set into several groups. At last, the conception of normalized variance is used on behalf of the information content of each band. The bands are sorted by the value of its normalized variance. Set needing number of bands, and the optimum band combination solution can be get by these three steps. This method retains the greatest degree of difference between the target of interest and is easy to achieve by computer automatically. Besides, false color image synthesis experiment is carried out using the bands selected by this method as well as other 3 methods to show the performance of method in this paper.

  5. Comparing the structure of an emerging market with a mature one under global perturbation

    NASA Astrophysics Data System (ADS)

    Namaki, A.; Jafari, G. R.; Raei, R.

    2011-09-01

    In this paper we investigate the Tehran stock exchange (TSE) and Dow Jones Industrial Average (DJIA) in terms of perturbed correlation matrices. To perturb a stock market, there are two methods, namely local and global perturbation. In the local method, we replace a correlation coefficient of the cross-correlation matrix with one calculated from two Gaussian-distributed time series, whereas in the global method, we reconstruct the correlation matrix after replacing the original return series with Gaussian-distributed time series. The local perturbation is just a technical study. We analyze these markets through two statistical approaches, random matrix theory (RMT) and the correlation coefficient distribution. By using RMT, we find that the largest eigenvalue is an influence that is common to all stocks and this eigenvalue has a peak during financial shocks. We find there are a few correlated stocks that make the essential robustness of the stock market but we see that by replacing these return time series with Gaussian-distributed time series, the mean values of correlation coefficients, the largest eigenvalues of the stock markets and the fraction of eigenvalues that deviate from the RMT prediction fall sharply in both markets. By comparing these two markets, we can see that the DJIA is more sensitive to global perturbations. These findings are crucial for risk management and portfolio selection.

  6. Agreement between ambulatory, home, and office blood pressure variability.

    PubMed

    Juhanoja, Eeva P; Niiranen, Teemu J; Johansson, Jouni K; Puukka, Pauli J; Jula, Antti M

    2016-01-01

    Ambulatory, home, and office blood pressure (BP) variability are often treated as a single entity. Our aim was to assess the agreement between these three methods for measuring BP variability. Twenty-four-hour ambulatory BP monitoring, 28 home BP measurements, and eight office BP measurements were performed on 461 population-based or hypertensive participants. Five variability indices were calculated for all measurement methods: SD, coefficient of variation, maximum-minimum difference, variability independent of the mean, and average real variability. Pearson's correlation coefficients were calculated for indices measured with different methods. The agreement between different measurement methods on the diagnoses of extreme BP variability (participants in the highest decile of variability) was assessed with kappa (κ) coefficients. SBP/DBP variability was greater in daytime (coefficient of variation: 9.8 ± 2.9/11.9 ± 3.6) and night-time ambulatory measurements (coefficient of variation: 8.6 ± 3.4/12.1 ± 4.5) than in home (coefficient of variation: 4.4 ± 1.8/4.7 ± 1.9) and office (coefficient of variation: 4.6 ± 2.4/5.2 ± 2.6) measurements (P < 0.001/0.001 for all). Pearson's correlation coefficients for systolic/diastolic daytime or night-time ambulatory-home, ambulatory-office, and home-office variability indices ranged between 0.07-0.25/0.12-0.23, 0.13-0.26/0.03-0.22 and 0.13-0.24/0.10-0.19, respectively, indicating, at most, a weak positive (r < 0.3) relationship. The agreement between measurement methods on diagnoses of extreme SBP/DBP variability was only slight (κ < 0.2), with the κ coefficients for daytime and night-time ambulatory-home, ambulatory-office, and home-office agreement varying between-0.014-0.20/0.061-0.15, 0.037-0.18/0.082-0.15, and 0.082-0.13/0.045-0.15, respectively. Shorter-term and longer-term BP variability assessed by different methods of BP measurement seem to correlate only weakly with each other. Our study suggests that BP variability measured by different methods and timeframes may reflect different phenomena, not a single entity.

  7. Body Adiposity Index Performance in Estimating Body Fat Percentage in Colombian College Students: Findings from the FUPRECOL—Adults Study

    PubMed Central

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio

    2017-01-01

    Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5))−18) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin’s concordance correlation coefficient, linear regression, Bland–Altman’s agreement analysis, concordance correlation coefficient (ρc) and the coefficient of determination (R2) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R2 = 0.384, p < 0.001. A paired-sample t-test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = −6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin’s concordance correlation coefficient was poor (ρc = 0.014, 95% CI = −0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels. PMID:28106719

  8. Application of the Gini correlation coefficient to infer regulatory relationships in transcriptome analysis.

    PubMed

    Ma, Chuang; Wang, Xiangfeng

    2012-09-01

    One of the computational challenges in plant systems biology is to accurately infer transcriptional regulation relationships based on correlation analyses of gene expression patterns. Despite several correlation methods that are applied in biology to analyze microarray data, concerns regarding the compatibility of these methods with the gene expression data profiled by high-throughput RNA transcriptome sequencing (RNA-Seq) technology have been raised. These concerns are mainly due to the fact that the distribution of read counts in RNA-Seq experiments is different from that of fluorescence intensities in microarray experiments. Therefore, a comprehensive evaluation of the existing correlation methods and, if necessary, introduction of novel methods into biology is appropriate. In this study, we compared four existing correlation methods used in microarray analysis and one novel method called the Gini correlation coefficient on previously published microarray-based and sequencing-based gene expression data in Arabidopsis (Arabidopsis thaliana) and maize (Zea mays). The comparisons were performed on more than 11,000 regulatory relationships in Arabidopsis, including 8,929 pairs of transcription factors and target genes. Our analyses pinpointed the strengths and weaknesses of each method and indicated that the Gini correlation can compensate for the shortcomings of the Pearson correlation, the Spearman correlation, the Kendall correlation, and the Tukey's biweight correlation. The Gini correlation method, with the other four evaluated methods in this study, was implemented as an R package named rsgcc that can be utilized as an alternative option for biologists to perform clustering analyses of gene expression patterns or transcriptional network analyses.

  9. Application of the Gini Correlation Coefficient to Infer Regulatory Relationships in Transcriptome Analysis[W][OA

    PubMed Central

    Ma, Chuang; Wang, Xiangfeng

    2012-01-01

    One of the computational challenges in plant systems biology is to accurately infer transcriptional regulation relationships based on correlation analyses of gene expression patterns. Despite several correlation methods that are applied in biology to analyze microarray data, concerns regarding the compatibility of these methods with the gene expression data profiled by high-throughput RNA transcriptome sequencing (RNA-Seq) technology have been raised. These concerns are mainly due to the fact that the distribution of read counts in RNA-Seq experiments is different from that of fluorescence intensities in microarray experiments. Therefore, a comprehensive evaluation of the existing correlation methods and, if necessary, introduction of novel methods into biology is appropriate. In this study, we compared four existing correlation methods used in microarray analysis and one novel method called the Gini correlation coefficient on previously published microarray-based and sequencing-based gene expression data in Arabidopsis (Arabidopsis thaliana) and maize (Zea mays). The comparisons were performed on more than 11,000 regulatory relationships in Arabidopsis, including 8,929 pairs of transcription factors and target genes. Our analyses pinpointed the strengths and weaknesses of each method and indicated that the Gini correlation can compensate for the shortcomings of the Pearson correlation, the Spearman correlation, the Kendall correlation, and the Tukey’s biweight correlation. The Gini correlation method, with the other four evaluated methods in this study, was implemented as an R package named rsgcc that can be utilized as an alternative option for biologists to perform clustering analyses of gene expression patterns or transcriptional network analyses. PMID:22797655

  10. A novel approach to detect respiratory phases from pulmonary acoustic signals using normalised power spectral density and fuzzy inference system.

    PubMed

    Palaniappan, Rajkumar; Sundaraj, Kenneth; Sundaraj, Sebastian; Huliraj, N; Revadi, S S

    2016-07-01

    Monitoring respiration is important in several medical applications. One such application is respiratory rate monitoring in patients with sleep apnoea. The respiratory rate in patients with sleep apnoea disorder is irregular compared with the controls. Respiratory phase detection is required for a proper monitoring of respiration in patients with sleep apnoea. To develop a model to detect the respiratory phases present in the pulmonary acoustic signals and to evaluate the performance of the model in detecting the respiratory phases. Normalised averaged power spectral density for each frame and change in normalised averaged power spectral density between the adjacent frames were fuzzified and fuzzy rules were formulated. The fuzzy inference system (FIS) was developed with both Mamdani and Sugeno methods. To evaluate the performance of both Mamdani and Sugeno methods, correlation coefficient and root mean square error (RMSE) were calculated. In the correlation coefficient analysis in evaluating the fuzzy model using Mamdani and Sugeno method, the strength of the correlation was found to be r = 0.9892 and r = 0.9964, respectively. The RMSE for Mamdani and Sugeno methods are RMSE = 0.0853 and RMSE = 0.0817, respectively. The correlation coefficient and the RMSE of the proposed fuzzy models in detecting the respiratory phases reveals that Sugeno method performs better compared with the Mamdani method. © 2014 John Wiley & Sons Ltd.

  11. A non-linear regression method for CT brain perfusion analysis

    NASA Astrophysics Data System (ADS)

    Bennink, E.; Oosterbroek, J.; Viergever, M. A.; Velthuis, B. K.; de Jong, H. W. A. M.

    2015-03-01

    CT perfusion (CTP) imaging allows for rapid diagnosis of ischemic stroke. Generation of perfusion maps from CTP data usually involves deconvolution algorithms providing estimates for the impulse response function in the tissue. We propose the use of a fast non-linear regression (NLR) method that we postulate has similar performance to the current academic state-of-art method (bSVD), but that has some important advantages, including the estimation of vascular permeability, improved robustness to tracer-delay, and very few tuning parameters, that are all important in stroke assessment. The aim of this study is to evaluate the fast NLR method against bSVD and a commercial clinical state-of-art method. The three methods were tested against a published digital perfusion phantom earlier used to illustrate the superiority of bSVD. In addition, the NLR and clinical methods were also tested against bSVD on 20 clinical scans. Pearson correlation coefficients were calculated for each of the tested methods. All three methods showed high correlation coefficients (>0.9) with the ground truth in the phantom. With respect to the clinical scans, the NLR perfusion maps showed higher correlation with bSVD than the perfusion maps from the clinical method. Furthermore, the perfusion maps showed that the fast NLR estimates are robust to tracer-delay. In conclusion, the proposed fast NLR method provides a simple and flexible way of estimating perfusion parameters from CT perfusion scans, with high correlation coefficients. This suggests that it could be a better alternative to the current clinical and academic state-of-art methods.

  12. The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.

    PubMed

    Erceg, David N; Dieli-Conwright, Christina M; Rossuello, Amerigo E; Jensky, Nicole E; Sun, Stephanie; Schroeder, E Todd

    2010-05-01

    Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses. Copyright 2010 Elsevier Inc. All rights reserved.

  13. Measuring the Cobb angle with the iPhone in kyphoses: a reliability study.

    PubMed

    Jacquot, Frederic; Charpentier, Axelle; Khelifi, Sofiane; Gastambide, Daniel; Rigal, Regis; Sautet, Alain

    2012-08-01

    Smartphones have gained widespread use in the healthcare field to fulfill a variety of tasks. We developed a small iPhone application to take advantage of the built-in position sensor to measure angles in a variety of spinal deformities. We present a reliability study of this tool in measuring kyphotic angles. Radiographs taken from 20 different patients' charts were presented to a panel of six operators at two different times. Radiographs were measured with the protractor and the iPhone application and statistical analysis was applied to measure intraclass correlation coefficients between both measurement methods, and to measure intra- and interobserver reliability The intraclass correlation coefficient calculated between methods (i.e. CobbMeter application on the iPhone versus standard method with the protractor) was 0.963 for all measures, indicating excellent correlation was obtained between the CobbMeter application and the standard method. The interobserver correlation coefficient was 0.965. The intraobserver ICC was 0.977, indicating excellent reproductibility of measurements at different times for all operators. The interobserver ICC between fellowship trained senior surgeons and general orthopaedic residents was 0.989. Consistently, the ICC for intraobserver and interobserver correlations was higher with the CobbMeter application than with the regular protractor method. This difference was not statistically significant. Measuring kyphotic angles with the iPhone application appears to be a valid procedure and is in no way inferior to the standard way of measuring the Cobb angle in kyphotic deformities.

  14. The Physical Significance of the Synthetic Running Correlation Coefficient and Its Applications in Oceanic and Atmospheric Studies

    NASA Astrophysics Data System (ADS)

    Zhao, Jinping; Cao, Yong; Wang, Xin

    2018-06-01

    In order to study the temporal variations of correlations between two time series, a running correlation coefficient (RCC) could be used. An RCC is calculated for a given time window, and the window is then moved sequentially through time. The current calculation method for RCCs is based on the general definition of the Pearson product-moment correlation coefficient, calculated with the data within the time window, which we call the local running correlation coefficient (LRCC). The LRCC is calculated via the two anomalies corresponding to the two local means, meanwhile, the local means also vary. It is cleared up that the LRCC reflects only the correlation between the two anomalies within the time window but fails to exhibit the contributions of the two varying means. To address this problem, two unchanged means obtained from all available data are adopted to calculate an RCC, which is called the synthetic running correlation coefficient (SRCC). When the anomaly variations are dominant, the two RCCs are similar. However, when the variations of the means are dominant, the difference between the two RCCs becomes obvious. The SRCC reflects the correlations of both the anomaly variations and the variations of the means. Therefore, the SRCCs from different time points are intercomparable. A criterion for the superiority of the RCC algorithm is that the average value of the RCC should be close to the global correlation coefficient calculated using all data. The SRCC always meets this criterion, while the LRCC sometimes fails. Therefore, the SRCC is better than the LRCC for running correlations. We suggest using the SRCC to calculate the RCCs.

  15. Experimental determination of turbulence in a GH2-GOX rocket combustion chamber

    NASA Technical Reports Server (NTRS)

    Tou, P.; Russell, R.; Ohara, J.

    1974-01-01

    The intensity of turbulence and the Lagrangian correlation coefficient for a gaseous rocket combustion chamber have been determined from the experimental measurements of the tracer gas diffusion. A combination of Taylor's turbulent diffusion theory and Spalding's numerical method for solving the conservation equations of fluid mechanics was used to calculate these quantities. Taylor's theory was extended to consider the inhomogeneity of the turbulence field in the axial direction of the combustion chamber. An exponential function was used to represent the Lagrangian correlation coefficient. The results indicate that the maximum value of the intensity of turbulence is about 15% and the Lagrangian correlation coefficient drops to about 0.12 in one inch of the chamber length.

  16. Biostatistics Series Module 6: Correlation and Linear Regression.

    PubMed

    Hazra, Avijit; Gogtay, Nithya

    2016-01-01

    Correlation and linear regression are the most commonly used techniques for quantifying the association between two numeric variables. Correlation quantifies the strength of the linear relationship between paired variables, expressing this as a correlation coefficient. If both variables x and y are normally distributed, we calculate Pearson's correlation coefficient ( r ). If normality assumption is not met for one or both variables in a correlation analysis, a rank correlation coefficient, such as Spearman's rho (ρ) may be calculated. A hypothesis test of correlation tests whether the linear relationship between the two variables holds in the underlying population, in which case it returns a P < 0.05. A 95% confidence interval of the correlation coefficient can also be calculated for an idea of the correlation in the population. The value r 2 denotes the proportion of the variability of the dependent variable y that can be attributed to its linear relation with the independent variable x and is called the coefficient of determination. Linear regression is a technique that attempts to link two correlated variables x and y in the form of a mathematical equation ( y = a + bx ), such that given the value of one variable the other may be predicted. In general, the method of least squares is applied to obtain the equation of the regression line. Correlation and linear regression analysis are based on certain assumptions pertaining to the data sets. If these assumptions are not met, misleading conclusions may be drawn. The first assumption is that of linear relationship between the two variables. A scatter plot is essential before embarking on any correlation-regression analysis to show that this is indeed the case. Outliers or clustering within data sets can distort the correlation coefficient value. Finally, it is vital to remember that though strong correlation can be a pointer toward causation, the two are not synonymous.

  17. Biostatistics Series Module 6: Correlation and Linear Regression

    PubMed Central

    Hazra, Avijit; Gogtay, Nithya

    2016-01-01

    Correlation and linear regression are the most commonly used techniques for quantifying the association between two numeric variables. Correlation quantifies the strength of the linear relationship between paired variables, expressing this as a correlation coefficient. If both variables x and y are normally distributed, we calculate Pearson's correlation coefficient (r). If normality assumption is not met for one or both variables in a correlation analysis, a rank correlation coefficient, such as Spearman's rho (ρ) may be calculated. A hypothesis test of correlation tests whether the linear relationship between the two variables holds in the underlying population, in which case it returns a P < 0.05. A 95% confidence interval of the correlation coefficient can also be calculated for an idea of the correlation in the population. The value r2 denotes the proportion of the variability of the dependent variable y that can be attributed to its linear relation with the independent variable x and is called the coefficient of determination. Linear regression is a technique that attempts to link two correlated variables x and y in the form of a mathematical equation (y = a + bx), such that given the value of one variable the other may be predicted. In general, the method of least squares is applied to obtain the equation of the regression line. Correlation and linear regression analysis are based on certain assumptions pertaining to the data sets. If these assumptions are not met, misleading conclusions may be drawn. The first assumption is that of linear relationship between the two variables. A scatter plot is essential before embarking on any correlation-regression analysis to show that this is indeed the case. Outliers or clustering within data sets can distort the correlation coefficient value. Finally, it is vital to remember that though strong correlation can be a pointer toward causation, the two are not synonymous. PMID:27904175

  18. Quantifying Abdominal Adipose Tissue and Thigh Muscle Volume and Hepatic Proton Density Fat Fraction: Repeatability and Accuracy of an MR Imaging-based, Semiautomated Analysis Method.

    PubMed

    Middleton, Michael S; Haufe, William; Hooker, Jonathan; Borga, Magnus; Dahlqvist Leinhard, Olof; Romu, Thobias; Tunón, Patrik; Hamilton, Gavin; Wolfson, Tanya; Gamst, Anthony; Loomba, Rohit; Sirlin, Claude B

    2017-05-01

    Purpose To determine the repeatability and accuracy of a commercially available magnetic resonance (MR) imaging-based, semiautomated method to quantify abdominal adipose tissue and thigh muscle volume and hepatic proton density fat fraction (PDFF). Materials and Methods This prospective study was institutional review board- approved and HIPAA compliant. All subjects provided written informed consent. Inclusion criteria were age of 18 years or older and willingness to participate. The exclusion criterion was contraindication to MR imaging. Three-dimensional T1-weighted dual-echo body-coil images were acquired three times. Source images were reconstructed to generate water and calibrated fat images. Abdominal adipose tissue and thigh muscle were segmented, and their volumes were estimated by using a semiautomated method and, as a reference standard, a manual method. Hepatic PDFF was estimated by using a confounder-corrected chemical shift-encoded MR imaging method with hybrid complex-magnitude reconstruction and, as a reference standard, MR spectroscopy. Tissue volume and hepatic PDFF intra- and interexamination repeatability were assessed by using intraclass correlation and coefficient of variation analysis. Tissue volume and hepatic PDFF accuracy were assessed by means of linear regression with the respective reference standards. Results Adipose and thigh muscle tissue volumes of 20 subjects (18 women; age range, 25-76 years; body mass index range, 19.3-43.9 kg/m 2 ) were estimated by using the semiautomated method. Intra- and interexamination intraclass correlation coefficients were 0.996-0.998 and coefficients of variation were 1.5%-3.6%. For hepatic MR imaging PDFF, intra- and interexamination intraclass correlation coefficients were greater than or equal to 0.994 and coefficients of variation were less than or equal to 7.3%. In the regression analyses of manual versus semiautomated volume and spectroscopy versus MR imaging, PDFF slopes and intercepts were close to the identity line, and correlations of determination at multivariate analysis (R 2 ) ranged from 0.744 to 0.994. Conclusion This MR imaging-based, semiautomated method provides high repeatability and accuracy for estimating abdominal adipose tissue and thigh muscle volumes and hepatic PDFF. © RSNA, 2017.

  19. A comparison of two indices for the intraclass correlation coefficient.

    PubMed

    Shieh, Gwowen

    2012-12-01

    In the present study, we examined the behavior of two indices for measuring the intraclass correlation in the one-way random effects model: the prevailing ICC(1) (Fisher, 1938) and the corrected eta-squared (Bliese & Halverson, 1998). These two procedures differ both in their methods of estimating the variance components that define the intraclass correlation coefficient and in their performance of bias and mean squared error in the estimation of the intraclass correlation coefficient. In contrast with the natural unbiased principle used to construct ICC(1), in the present study it was analytically shown that the corrected eta-squared estimator is identical to the maximum likelihood estimator and the pairwise estimator under equal group sizes. Moreover, the empirical results obtained from the present Monte Carlo simulation study across various group structures revealed the mutual dominance relationship between their truncated versions for negative values. The corrected eta-squared estimator performs better than the ICC(1) estimator when the underlying population intraclass correlation coefficient is small. Conversely, ICC(1) has a clear advantage over the corrected eta-squared for medium and large magnitudes of population intraclass correlation coefficient. The conceptual description and numerical investigation provide guidelines to help researchers choose between the two indices for more accurate reliability analysis in multilevel research.

  20. The use of least squares methods in functional optimization of energy use prediction models

    NASA Astrophysics Data System (ADS)

    Bourisli, Raed I.; Al-Shammeri, Basma S.; AlAnzi, Adnan A.

    2012-06-01

    The least squares method (LSM) is used to optimize the coefficients of a closed-form correlation that predicts the annual energy use of buildings based on key envelope design and thermal parameters. Specifically, annual energy use is related to a number parameters like the overall heat transfer coefficients of the wall, roof and glazing, glazing percentage, and building surface area. The building used as a case study is a previously energy-audited mosque in a suburb of Kuwait City, Kuwait. Energy audit results are used to fine-tune the base case mosque model in the VisualDOE{trade mark, serif} software. Subsequently, 1625 different cases of mosques with varying parameters were developed and simulated in order to provide the training data sets for the LSM optimizer. Coefficients of the proposed correlation are then optimized using multivariate least squares analysis. The objective is to minimize the difference between the correlation-predicted results and the VisualDOE-simulation results. It was found that the resulting correlation is able to come up with coefficients for the proposed correlation that reduce the difference between the simulated and predicted results to about 0.81%. In terms of the effects of the various parameters, the newly-defined weighted surface area parameter was found to have the greatest effect on the normalized annual energy use. Insulating the roofs and walls also had a major effect on the building energy use. The proposed correlation and methodology can be used during preliminary design stages to inexpensively assess the impacts of various design variables on the expected energy use. On the other hand, the method can also be used by municipality officials and planners as a tool for recommending energy conservation measures and fine-tuning energy codes.

  1. Adaptive Green-Kubo estimates of transport coefficients from molecular dynamics based on robust error analysis.

    PubMed

    Jones, Reese E; Mandadapu, Kranthi K

    2012-04-21

    We present a rigorous Green-Kubo methodology for calculating transport coefficients based on on-the-fly estimates of: (a) statistical stationarity of the relevant process, and (b) error in the resulting coefficient. The methodology uses time samples efficiently across an ensemble of parallel replicas to yield accurate estimates, which is particularly useful for estimating the thermal conductivity of semi-conductors near their Debye temperatures where the characteristic decay times of the heat flux correlation functions are large. Employing and extending the error analysis of Zwanzig and Ailawadi [Phys. Rev. 182, 280 (1969)] and Frenkel [in Proceedings of the International School of Physics "Enrico Fermi", Course LXXV (North-Holland Publishing Company, Amsterdam, 1980)] to the integral of correlation, we are able to provide tight theoretical bounds for the error in the estimate of the transport coefficient. To demonstrate the performance of the method, four test cases of increasing computational cost and complexity are presented: the viscosity of Ar and water, and the thermal conductivity of Si and GaN. In addition to producing accurate estimates of the transport coefficients for these materials, this work demonstrates precise agreement of the computed variances in the estimates of the correlation and the transport coefficient with the extended theory based on the assumption that fluctuations follow a Gaussian process. The proposed algorithm in conjunction with the extended theory enables the calculation of transport coefficients with the Green-Kubo method accurately and efficiently.

  2. Adaptive Green-Kubo estimates of transport coefficients from molecular dynamics based on robust error analysis

    NASA Astrophysics Data System (ADS)

    Jones, Reese E.; Mandadapu, Kranthi K.

    2012-04-01

    We present a rigorous Green-Kubo methodology for calculating transport coefficients based on on-the-fly estimates of: (a) statistical stationarity of the relevant process, and (b) error in the resulting coefficient. The methodology uses time samples efficiently across an ensemble of parallel replicas to yield accurate estimates, which is particularly useful for estimating the thermal conductivity of semi-conductors near their Debye temperatures where the characteristic decay times of the heat flux correlation functions are large. Employing and extending the error analysis of Zwanzig and Ailawadi [Phys. Rev. 182, 280 (1969)], 10.1103/PhysRev.182.280 and Frenkel [in Proceedings of the International School of Physics "Enrico Fermi", Course LXXV (North-Holland Publishing Company, Amsterdam, 1980)] to the integral of correlation, we are able to provide tight theoretical bounds for the error in the estimate of the transport coefficient. To demonstrate the performance of the method, four test cases of increasing computational cost and complexity are presented: the viscosity of Ar and water, and the thermal conductivity of Si and GaN. In addition to producing accurate estimates of the transport coefficients for these materials, this work demonstrates precise agreement of the computed variances in the estimates of the correlation and the transport coefficient with the extended theory based on the assumption that fluctuations follow a Gaussian process. The proposed algorithm in conjunction with the extended theory enables the calculation of transport coefficients with the Green-Kubo method accurately and efficiently.

  3. Evaluation of the pulse-contour method of determining stroke volume in man.

    NASA Technical Reports Server (NTRS)

    Alderman, E. L.; Branzi, A.; Sanders, W.; Brown, B. W.; Harrison, D. C.

    1972-01-01

    The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.

  4. Wavelet-based image compression using shuffling and bit plane correlation

    NASA Astrophysics Data System (ADS)

    Kim, Seungjong; Jeong, Jechang

    2000-12-01

    In this paper, we propose a wavelet-based image compression method using shuffling and bit plane correlation. The proposed method improves coding performance in two steps: (1) removing the sign bit plane by shuffling process on quantized coefficients, (2) choosing the arithmetic coding context according to maximum correlation direction. The experimental results are comparable or superior for some images with low correlation, to existing coders.

  5. Development and validation of a new Prescription Quality Index

    PubMed Central

    Hassan, Norul Badriah; Ismail, Hasanah Che; Naing, Lin; Conroy, Ronán M; Abdul Rahman, Abdul Rashid

    2010-01-01

    AIMS The aims were to develop and validate a new Prescription Quality Index (PQI) for the measurement of prescription quality in chronic diseases. METHODS The PQI were developed and validated based on three separate surveys and one pilot study. Criteria were developed based on literature search, discussions and brainstorming sessions. Validity of the criteria was examined using modified Delphi method. Pre-testing was performed on 30 patients suffering from chronic diseases. The modified version was then subjected to reviews by pharmacists and clinicians in two separate surveys. The rater-based PQI with 22 criteria was then piloted in 120 patients with chronic illnesses. Results were analysed using SPSS version 12.0.1 RESULTS Exploratory principal components analysis revealed multiple factors contributing to prescription quality. Cronbach's α for the entire 22 criteria was 0.60. The average intra-rater and inter-rater reliability showed good to moderate stability (intraclass correlation coefficient 0.76 and 0.52, respectively). The PQI was significantly and negatively correlated with age (correlation coefficient −0.34, P < 0.001), number of drugs in prescriptions (correlation coefficient −0.51, P < 0.001) and number of chronic diseases/conditions (correlation coefficient −0.35, P < 0.001). CONCLUSIONS The PQI is a promising new instrument for measuring prescription quality. It has been shown that the PQI is a valid, reliable and responsive tool to measure quality of prescription in chronic diseases. PMID:20840442

  6. Prediction of soil organic carbon partition coefficients by soil column liquid chromatography.

    PubMed

    Guo, Rongbo; Liang, Xinmiao; Chen, Jiping; Wu, Wenzhong; Zhang, Qing; Martens, Dieter; Kettrup, Antonius

    2004-04-30

    To avoid the limitation of the widely used prediction methods of soil organic carbon partition coefficients (KOC) from hydrophobic parameters, e.g., the n-octanol/water partition coefficients (KOW) and the reversed phase high performance liquid chromatographic (RP-HPLC) retention factors, the soil column liquid chromatographic (SCLC) method was developed for KOC prediction. The real soils were used as the packing materials of RP-HPLC columns, and the correlations between the retention factors of organic compounds on soil columns (ksoil) and KOC measured by batch equilibrium method were studied. Good correlations were achieved between ksoil and KOC for three types of soils with different properties. All the square of the correlation coefficients (R2) of the linear regression between log ksoil and log KOC were higher than 0.89 with standard deviations of less than 0.21. In addition, the prediction of KOC from KOW and the RP-HPLC retention factors on cyanopropyl (CN) stationary phase (kCN) was comparatively evaluated for the three types of soils. The results show that the prediction of KOC from kCN and KOW is only applicable to some specific types of soils. The results obtained in the present study proved that the SCLC method is appropriate for the KOC prediction for different types of soils, however the applicability of using hydrophobic parameters to predict KOC largely depends on the properties of soil concerned.

  7. A method comparison of a food frequency questionnaire to measure folate, choline, betaine, vitamin C and carotenoids with 24-h dietary recalls in women of reproductive age.

    PubMed

    Coathup, V; Wheeler, S; Smith, L

    2016-03-01

    The objective of this study was to conduct a method comparison of a modified food frequency questionnaire (FFQ), designed to estimate usual dietary intake of selected micronutrients and antioxidants including folate, choline, betaine, vitamin C and carotenoids (α-carotene, β-carotene, lutein, lycopene and β-cryptoxanthin) with 24-h dietary recalls (24-HR) in women of reproductive age. Sixty-four British women of reproductive age (18-40 years) were recruited in Oxford, UK and provided complete dietary data for analysis. We compared micronutrient estimates from the FFQ against estimates derived from three multiple-pass, 24-HR interviews, by evaluating Pearson's correlation coefficients and Bland-Altman plots. Median intakes of most nutrients were higher when measured by FFQ compared with 24-HR. Strong correlation coefficients were observed for folate (r=0.80) and choline (r=0.68), whereas moderate correlation coefficients were observed for vitamin C (0.50) and lycopene (0.43). Weak correlation coefficients were observed for betaine (0.39) and other carotenoids (r=0.26-0.38). Bland-Altman plots indicated that there was a large amount of variability in the FFQ estimates of nutrient intakes compared to those using 24-HR, particularly for carotenoids. The findings indicate that this FFQ estimated higher mean intakes for most nutrients. Pearson's correlation coefficients were comparable with previous research; however, the Bland-Altman plots suggest a high variability in mean nutrient estimates between the FFQ and 24-h. We recommend further investigation of the validity of this FFQ before use.

  8. Correlation and simple linear regression.

    PubMed

    Zou, Kelly H; Tuncali, Kemal; Silverman, Stuart G

    2003-06-01

    In this tutorial article, the concepts of correlation and regression are reviewed and demonstrated. The authors review and compare two correlation coefficients, the Pearson correlation coefficient and the Spearman rho, for measuring linear and nonlinear relationships between two continuous variables. In the case of measuring the linear relationship between a predictor and an outcome variable, simple linear regression analysis is conducted. These statistical concepts are illustrated by using a data set from published literature to assess a computed tomography-guided interventional technique. These statistical methods are important for exploring the relationships between variables and can be applied to many radiologic studies.

  9. Complex versus Simple Modeling for DIF Detection: When the Intraclass Correlation Coefficient (?) of the Studied Item Is Less Than the ? of the Total Score

    ERIC Educational Resources Information Center

    Jin, Ying; Myers, Nicholas D.; Ahn, Soyeon

    2014-01-01

    Previous research has demonstrated that differential item functioning (DIF) methods that do not account for multilevel data structure could result in too frequent rejection of the null hypothesis (i.e., no DIF) when the intraclass correlation coefficient (?) of the studied item was the same as the ? of the total score. The current study extended…

  10. Determination of facial symmetry in unilateral cleft lip and palate patients from three-dimensional data: technical report and assessment of measurement errors.

    PubMed

    Nkenke, Emeka; Lehner, Bernhard; Kramer, Manuel; Haeusler, Gerd; Benz, Stefanie; Schuster, Maria; Neukam, Friedrich W; Vairaktaris, Eleftherios G; Wurm, Jochen

    2006-03-01

    To assess measurement errors of a novel technique for the three-dimensional determination of the degree of facial symmetry in patients suffering from unilateral cleft lip and palate malformations. Technical report, reliability study. Cleft Lip and Palate Center of the University of Erlangen-Nuremberg, Erlangen, Germany. The three-dimensional facial surface data of five 10-year-old unilateral cleft lip and palate patients were subjected to the analysis. Distances, angles, surface areas, and volumes were assessed twice. Calculations were made for method error, intraclass correlation coefficient, and repeatability of the measurements of distances, angles, surface areas, and volumes. The method errors were less than 1 mm for distances and less than 1.5 degrees for angles. The intraclass correlation coefficients showed values greater than .90 for all parameters. The repeatability values were comparable for cleft and noncleft sides. The small method errors, high intraclass correlation coefficients, and comparable repeatability values for cleft and noncleft sides reveal that the new technique is appropriate for clinical use.

  11. A Method of Q-Matrix Validation for the Linear Logistic Test Model

    PubMed Central

    Baghaei, Purya; Hohensinn, Christine

    2017-01-01

    The linear logistic test model (LLTM) is a well-recognized psychometric model for examining the components of difficulty in cognitive tests and validating construct theories. The plausibility of the construct model, summarized in a matrix of weights, known as the Q-matrix or weight matrix, is tested by (1) comparing the fit of LLTM with the fit of the Rasch model (RM) using the likelihood ratio (LR) test and (2) by examining the correlation between the Rasch model item parameters and LLTM reconstructed item parameters. The problem with the LR test is that it is almost always significant and, consequently, LLTM is rejected. The drawback of examining the correlation coefficient is that there is no cut-off value or lower bound for the magnitude of the correlation coefficient. In this article we suggest a simulation method to set a minimum benchmark for the correlation between item parameters from the Rasch model and those reconstructed by the LLTM. If the cognitive model is valid then the correlation coefficient between the RM-based item parameters and the LLTM-reconstructed item parameters derived from the theoretical weight matrix should be greater than those derived from the simulated matrices. PMID:28611721

  12. Relative validity of an FFQ to estimate daily food and nutrient intakes for Chilean adults.

    PubMed

    Dehghan, Mahshid; Martinez, Solange; Zhang, Xiaohe; Seron, Pamela; Lanas, Fernando; Islam, Shofiqul; Merchant, Anwar T

    2013-10-01

    FFQ are commonly used to rank individuals by their food and nutrient intakes in large epidemiological studies. The purpose of the present study was to develop and validate an FFQ to rank individuals participating in an ongoing Prospective Urban and Rural Epidemiological (PURE) study in Chile. An FFQ and four 24 h dietary recalls were completed over 1 year. Pearson correlation coefficients, energy-adjusted and de-attenuated correlations and weighted kappa were computed between the dietary recalls and the FFQ. The level of agreement between the two dietary assessment methods was evaluated by Bland-Altman analysis. Temuco, Chile. Overall, 166 women and men enrolled in the present study. One hundred men and women participated in FFQ development and sixty-six individuals participated in FFQ validation. The FFQ consisted of 109 food items. For nutrients, the crude correlation coefficients between the dietary recalls and FFQ varied from 0.14 (protein) to 0.44 (fat). Energy adjustment and de-attenuation improved correlation coefficients and almost all correlation coefficients exceeded 0.40. Similar correlation coefficients were observed for food groups; the highest de-attenuated energy adjusted correlation coefficient was found for margarine and butter (0.75) and the lowest for potatoes (0.12). The FFQ showed moderate to high agreement for most nutrients and food groups, and can be used to rank individuals based on energy, nutrient and food intakes. The validation study was conducted in a unique setting and indicated that the tool is valid for use by adults in Chile.

  13. [Habitat suitability index of larval Japanese Halfbeak (Hyporhamphus sajori) in Bohai Sea based on geographically weighted regression.

    PubMed

    Zhao, Yang; Zhang, Xue Qing; Bian, Xiao Dong

    2018-01-01

    To investigate the early supplementary processes of fishre sources in the Bohai Sea, the geographically weighted regression (GWR) was introduced to the habitat suitability index (HSI) model. The Bohai Sea larval Japanese Halfbeak HSI GWR model was established with four environmental variables, including sea surface temperature (SST), sea surface salinity (SSS), water depth (DEP), and chlorophyll a concentration (Chl a). Results of the simulation showed that the four variables had different performances in August 2015. SST and Chl a were global variables, and had little impacts on HSI, with the regression coefficients of -0.027 and 0.006, respectively. SSS and DEP were local variables, and had larger impacts on HSI, while the average values of absolute values of their regression coefficients were 0.075 and 0.129, respectively. In the central Bohai Sea, SSS showed a negative correlation with HSI, and the most negative correlation coefficient was -0.3. In contrast, SSS was correlated positively but weakly with HSI in the three bays of Bohai Sea, and the largest correlation coefficient was 0.1. In particular, DEP and HSI were negatively correlated in the entire Bohai Sea, while they were more negatively correlated in the three bays of Bohai than in the central Bohai Sea, and the most negative correlation coefficient was -0.16 in the three bays. The Poisson regression coefficient of the HSI GWR model was 0.705, consistent with field measurements. Therefore, it could provide a new method for the research on fish habitats in the future.

  14. Development of stock correlation networks using mutual information and financial big data.

    PubMed

    Guo, Xue; Zhang, Hu; Tian, Tianhai

    2018-01-01

    Stock correlation networks use stock price data to explore the relationship between different stocks listed in the stock market. Currently this relationship is dominantly measured by the Pearson correlation coefficient. However, financial data suggest that nonlinear relationships may exist in the stock prices of different shares. To address this issue, this work uses mutual information to characterize the nonlinear relationship between stocks. Using 280 stocks traded at the Shanghai Stocks Exchange in China during the period of 2014-2016, we first compare the effectiveness of the correlation coefficient and mutual information for measuring stock relationships. Based on these two measures, we then develop two stock networks using the Minimum Spanning Tree method and study the topological properties of these networks, including degree, path length and the power-law distribution. The relationship network based on mutual information has a better distribution of the degree and larger value of the power-law distribution than those using the correlation coefficient. Numerical results show that mutual information is a more effective approach than the correlation coefficient to measure the stock relationship in a stock market that may undergo large fluctuations of stock prices.

  15. Development of stock correlation networks using mutual information and financial big data

    PubMed Central

    Guo, Xue; Zhang, Hu

    2018-01-01

    Stock correlation networks use stock price data to explore the relationship between different stocks listed in the stock market. Currently this relationship is dominantly measured by the Pearson correlation coefficient. However, financial data suggest that nonlinear relationships may exist in the stock prices of different shares. To address this issue, this work uses mutual information to characterize the nonlinear relationship between stocks. Using 280 stocks traded at the Shanghai Stocks Exchange in China during the period of 2014-2016, we first compare the effectiveness of the correlation coefficient and mutual information for measuring stock relationships. Based on these two measures, we then develop two stock networks using the Minimum Spanning Tree method and study the topological properties of these networks, including degree, path length and the power-law distribution. The relationship network based on mutual information has a better distribution of the degree and larger value of the power-law distribution than those using the correlation coefficient. Numerical results show that mutual information is a more effective approach than the correlation coefficient to measure the stock relationship in a stock market that may undergo large fluctuations of stock prices. PMID:29668715

  16. Investigating Correlation between Protein Sequence Similarity and Semantic Similarity Using Gene Ontology Annotations.

    PubMed

    Ikram, Najmul; Qadir, Muhammad Abdul; Afzal, Muhammad Tanvir

    2018-01-01

    Sequence similarity is a commonly used measure to compare proteins. With the increasing use of ontologies, semantic (function) similarity is getting importance. The correlation between these measures has been applied in the evaluation of new semantic similarity methods, and in protein function prediction. In this research, we investigate the relationship between the two similarity methods. The results suggest absence of a strong correlation between sequence and semantic similarities. There is a large number of proteins with low sequence similarity and high semantic similarity. We observe that Pearson's correlation coefficient is not sufficient to explain the nature of this relationship. Interestingly, the term semantic similarity values above 0 and below 1 do not seem to play a role in improving the correlation. That is, the correlation coefficient depends only on the number of common GO terms in proteins under comparison, and the semantic similarity measurement method does not influence it. Semantic similarity and sequence similarity have a distinct behavior. These findings are of significant effect for future works on protein comparison, and will help understand the semantic similarity between proteins in a better way.

  17. Observed intra-cluster correlation coefficients in a cluster survey sample of patient encounters in general practice in Australia

    PubMed Central

    Knox, Stephanie A; Chondros, Patty

    2004-01-01

    Background Cluster sample study designs are cost effective, however cluster samples violate the simple random sample assumption of independence of observations. Failure to account for the intra-cluster correlation of observations when sampling through clusters may lead to an under-powered study. Researchers therefore need estimates of intra-cluster correlation for a range of outcomes to calculate sample size. We report intra-cluster correlation coefficients observed within a large-scale cross-sectional study of general practice in Australia, where the general practitioner (GP) was the primary sampling unit and the patient encounter was the unit of inference. Methods Each year the Bettering the Evaluation and Care of Health (BEACH) study recruits a random sample of approximately 1,000 GPs across Australia. Each GP completes details of 100 consecutive patient encounters. Intra-cluster correlation coefficients were estimated for patient demographics, morbidity managed and treatments received. Intra-cluster correlation coefficients were estimated for descriptive outcomes and for associations between outcomes and predictors and were compared across two independent samples of GPs drawn three years apart. Results Between April 1999 and March 2000, a random sample of 1,047 Australian general practitioners recorded details of 104,700 patient encounters. Intra-cluster correlation coefficients for patient demographics ranged from 0.055 for patient sex to 0.451 for language spoken at home. Intra-cluster correlations for morbidity variables ranged from 0.005 for the management of eye problems to 0.059 for management of psychological problems. Intra-cluster correlation for the association between two variables was smaller than the descriptive intra-cluster correlation of each variable. When compared with the April 2002 to March 2003 sample (1,008 GPs) the estimated intra-cluster correlation coefficients were found to be consistent across samples. Conclusions The demonstrated precision and reliability of the estimated intra-cluster correlations indicate that these coefficients will be useful for calculating sample sizes in future general practice surveys that use the GP as the primary sampling unit. PMID:15613248

  18. A robust bayesian estimate of the concordance correlation coefficient.

    PubMed

    Feng, Dai; Baumgartner, Richard; Svetnik, Vladimir

    2015-01-01

    A need for assessment of agreement arises in many situations including statistical biomarker qualification or assay or method validation. Concordance correlation coefficient (CCC) is one of the most popular scaled indices reported in evaluation of agreement. Robust methods for CCC estimation currently present an important statistical challenge. Here, we propose a novel Bayesian method of robust estimation of CCC based on multivariate Student's t-distribution and compare it with its alternatives. Furthermore, we extend the method to practically relevant settings, enabling incorporation of confounding covariates and replications. The superiority of the new approach is demonstrated using simulation as well as real datasets from biomarker application in electroencephalography (EEG). This biomarker is relevant in neuroscience for development of treatments for insomnia.

  19. Multilevel geometry optimization

    NASA Astrophysics Data System (ADS)

    Rodgers, Jocelyn M.; Fast, Patton L.; Truhlar, Donald G.

    2000-02-01

    Geometry optimization has been carried out for three test molecules using six multilevel electronic structure methods, in particular Gaussian-2, Gaussian-3, multicoefficient G2, multicoefficient G3, and two multicoefficient correlation methods based on correlation-consistent basis sets. In the Gaussian-2 and Gaussian-3 methods, various levels are added and subtracted with unit coefficients, whereas the multicoefficient Gaussian-x methods involve noninteger parameters as coefficients. The multilevel optimizations drop the average error in the geometry (averaged over the 18 cases) by a factor of about two when compared to the single most expensive component of a given multilevel calculation, and in all 18 cases the accuracy of the atomization energy for the three test molecules improves; with an average improvement of 16.7 kcal/mol.

  20. [Similarity system theory to evaluate similarity of chromatographic fingerprints of traditional Chinese medicine].

    PubMed

    Liu, Yongsuo; Meng, Qinghua; Jiang, Shumin; Hu, Yuzhu

    2005-03-01

    The similarity evaluation of the fingerprints is one of the most important problems in the quality control of the traditional Chinese medicine (TCM). Similarity measures used to evaluate the similarity of the common peaks in the chromatogram of TCM have been discussed. Comparative studies were carried out among correlation coefficient, cosine of the angle and an improved extent similarity method using simulated data and experimental data. Correlation coefficient and cosine of the angle are not sensitive to the differences of the data set. They are still not sensitive to the differences of the data even after normalization. According to the similarity system theory, an improved extent similarity method was proposed. The improved extent similarity is more sensitive to the differences of the data sets than correlation coefficient and cosine of the angle. And the character of the data sets needs not to be changed compared with log-transformation. The improved extent similarity can be used to evaluate the similarity of the chromatographic fingerprints of TCM.

  1. A secure image encryption method based on dynamic harmony search (DHS) combined with chaotic map

    NASA Astrophysics Data System (ADS)

    Mirzaei Talarposhti, Khadijeh; Khaki Jamei, Mehrzad

    2016-06-01

    In recent years, there has been increasing interest in the security of digital images. This study focuses on the gray scale image encryption using dynamic harmony search (DHS). In this research, first, a chaotic map is used to create cipher images, and then the maximum entropy and minimum correlation coefficient is obtained by applying a harmony search algorithm on them. This process is divided into two steps. In the first step, the diffusion of a plain image using DHS to maximize the entropy as a fitness function will be performed. However, in the second step, a horizontal and vertical permutation will be applied on the best cipher image, which is obtained in the previous step. Additionally, DHS has been used to minimize the correlation coefficient as a fitness function in the second step. The simulation results have shown that by using the proposed method, the maximum entropy and the minimum correlation coefficient, which are approximately 7.9998 and 0.0001, respectively, have been obtained.

  2. Nondestructive Measurement of Dynamic Modulus for Cellulose Nanofibril Films

    Treesearch

    Yan Qing; Robert J. Ross; Zhiyong Cai; Yiqiang Wu

    2013-01-01

    Nondestructive evaluation of cellulose nanofibril (CNF) films was performed using cantilever beam vibration (CBV) and acoustic methods to measure dynamic modulus. Static modulus was tested using tensile tension method. Correlation analysis shows the data measured by CBV has little linear relationship with static modulus, possessing a correlation coefficient (R

  3. Automated brain tumor segmentation in magnetic resonance imaging based on sliding-window technique and symmetry analysis.

    PubMed

    Lian, Yanyun; Song, Zhijian

    2014-01-01

    Brain tumor segmentation from magnetic resonance imaging (MRI) is an important step toward surgical planning, treatment planning, monitoring of therapy. However, manual tumor segmentation commonly used in clinic is time-consuming and challenging, and none of the existed automated methods are highly robust, reliable and efficient in clinic application. An accurate and automated tumor segmentation method has been developed for brain tumor segmentation that will provide reproducible and objective results close to manual segmentation results. Based on the symmetry of human brain, we employed sliding-window technique and correlation coefficient to locate the tumor position. At first, the image to be segmented was normalized, rotated, denoised, and bisected. Subsequently, through vertical and horizontal sliding-windows technique in turn, that is, two windows in the left and the right part of brain image moving simultaneously pixel by pixel in two parts of brain image, along with calculating of correlation coefficient of two windows, two windows with minimal correlation coefficient were obtained, and the window with bigger average gray value is the location of tumor and the pixel with biggest gray value is the locating point of tumor. At last, the segmentation threshold was decided by the average gray value of the pixels in the square with center at the locating point and 10 pixels of side length, and threshold segmentation and morphological operations were used to acquire the final tumor region. The method was evaluated on 3D FSPGR brain MR images of 10 patients. As a result, the average ratio of correct location was 93.4% for 575 slices containing tumor, the average Dice similarity coefficient was 0.77 for one scan, and the average time spent on one scan was 40 seconds. An fully automated, simple and efficient segmentation method for brain tumor is proposed and promising for future clinic use. Correlation coefficient is a new and effective feature for tumor location.

  4. Multiscale Detrended Cross-Correlation Analysis of STOCK Markets

    NASA Astrophysics Data System (ADS)

    Yin, Yi; Shang, Pengjian

    2014-06-01

    In this paper, we employ the detrended cross-correlation analysis (DCCA) to investigate the cross-correlations between different stock markets. We report the results of cross-correlated behaviors in US, Chinese and European stock markets in period 1997-2012 by using DCCA method. The DCCA shows the cross-correlated behaviors of intra-regional and inter-regional stock markets in the short and long term which display the similarities and differences of cross-correlated behaviors simply and roughly and the persistence of cross-correlated behaviors of fluctuations. Then, because of the limitation and inapplicability of DCCA method, we propose multiscale detrended cross-correlation analysis (MSDCCA) method to avoid "a priori" selecting the ranges of scales over which two coefficients of the classical DCCA method are identified, and employ MSDCCA to reanalyze these cross-correlations to exhibit some important details such as the existence and position of minimum, maximum and bimodal distribution which are lost if the scale structure is described by two coefficients only and essential differences and similarities in the scale structures of cross-correlation of intra-regional and inter-regional markets. More statistical characteristics of cross-correlation obtained by MSDCCA method help us to understand how two different stock markets influence each other and to analyze the influence from thus two inter-regional markets on the cross-correlation in detail, thus we get a richer and more detailed knowledge of the complex evolutions of dynamics of the cross-correlations between stock markets. The application of MSDCCA is important to promote our understanding of the internal mechanisms and structures of financial markets and helps to forecast the stock indices based on our current results demonstrated the cross-correlations between stock indices. We also discuss the MSDCCA methods of secant rolling window with different sizes and, lastly, provide some relevant implications and issue.

  5. Correlation analysis of respiratory signals by using parallel coordinate plots.

    PubMed

    Saatci, Esra

    2018-01-01

    The understanding of the bonds and the relationships between the respiratory signals, i.e. the airflow, the mouth pressure, the relative temperature and the relative humidity during breathing may provide the improvement on the measurement methods of respiratory mechanics and sensor designs or the exploration of the several possible applications in the analysis of respiratory disorders. Therefore, the main objective of this study was to propose a new combination of methods in order to determine the relationship between respiratory signals as a multidimensional data. In order to reveal the coupling between the processes two very different methods were used: the well-known statistical correlation analysis (i.e. Pearson's correlation and cross-correlation coefficient) and parallel coordinate plots (PCPs). Curve bundling with the number intersections for the correlation analysis, Least Mean Square Time Delay Estimator (LMS-TDE) for the point delay detection and visual metrics for the recognition of the visual structures were proposed and utilized in PCP. The number of intersections was increased when the correlation coefficient changed from high positive to high negative correlation between the respiratory signals, especially if whole breath was processed. LMS-TDE coefficients plotted in PCP indicated well-matched point delay results to the findings in the correlation analysis. Visual inspection of PCB by visual metrics showed range, dispersions, entropy comparisons and linear and sinusoidal-like relationships between the respiratory signals. It is demonstrated that the basic correlation analysis together with the parallel coordinate plots perceptually motivates the visual metrics in the display and thus can be considered as an aid to the user analysis by providing meaningful views of the data. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. A Rapid Identification Method for Calamine Using Near-Infrared Spectroscopy Based on Multi-Reference Correlation Coefficient Method and Back Propagation Artificial Neural Network.

    PubMed

    Sun, Yangbo; Chen, Long; Huang, Bisheng; Chen, Keli

    2017-07-01

    As a mineral, the traditional Chinese medicine calamine has a similar shape to many other minerals. Investigations of commercially available calamine samples have shown that there are many fake and inferior calamine goods sold on the market. The conventional identification method for calamine is complicated, therefore as a result of the large scale of calamine samples, a rapid identification method is needed. To establish a qualitative model using near-infrared (NIR) spectroscopy for rapid identification of various calamine samples, large quantities of calamine samples including crude products, counterfeits and processed products were collected and correctly identified using the physicochemical and powder X-ray diffraction method. The NIR spectroscopy method was used to analyze these samples by combining the multi-reference correlation coefficient (MRCC) method and the error back propagation artificial neural network algorithm (BP-ANN), so as to realize the qualitative identification of calamine samples. The accuracy rate of the model based on NIR and MRCC methods was 85%; in addition, the model, which took comprehensive multiple factors into consideration, can be used to identify crude calamine products, its counterfeits and processed products. Furthermore, by in-putting the correlation coefficients of multiple references as the spectral feature data of samples into BP-ANN, a BP-ANN model of qualitative identification was established, of which the accuracy rate was increased to 95%. The MRCC method can be used as a NIR-based method in the process of BP-ANN modeling.

  7. Establishment of a Simple and Convenient Method for Folic Acid Enzyme Chemiluminescence Immunoassay

    NASA Astrophysics Data System (ADS)

    Liu, Ting; Zeng, Ling; Yu, Zhengwei; Yang, Yanfei; Qu, Yunhuan

    2018-01-01

    The enzyme chemiluminescence new immunoassay for folic acid (FA) was established by competition model. Add FA samples to a microtiter plate precoated with the goat anti-mouse IgG firstly, then add enzyme abled FA and FA monoclonal antibody (McAb). The values of CLIA were measured to reflect the quantity of FA. The limit of detection(LOD) of assay is 0.37ng/mL. The assay shows good correlation during 1∼30 ng/mL with correlation coefficient 0.9976. The intra- and inter-assay coefficients of variation are 4.8 % ∼ 7.3 % and 6.1 % ∼ 12.2 %, respectively. The recovery of folic acid in serum is 90.4 %∼113.2 %. Compared with determine value clinically in chemiluminescence immunoassay kit from Roche company, the correlative equation is y = 0.9689x + 0.0228, and correlation coefficient is 0.9780. Various components and kit overall show good stabilities. This method is simple and convenient, and has low LOD value. The method has overcome the shortcomings of the present references. It is easy to apply and has broad clinical application prospect. It lays an experimental foundation for the preparation of Mc Ab against folic acid and the development of domestic kit.

  8. Estimated Accuracy of Three Common Trajectory Statistical Methods

    NASA Technical Reports Server (NTRS)

    Kabashnikov, Vitaliy P.; Chaikovsky, Anatoli P.; Kucsera, Tom L.; Metelskaya, Natalia S.

    2011-01-01

    Three well-known trajectory statistical methods (TSMs), namely concentration field (CF), concentration weighted trajectory (CWT), and potential source contribution function (PSCF) methods were tested using known sources and artificially generated data sets to determine the ability of TSMs to reproduce spatial distribution of the sources. In the works by other authors, the accuracy of the trajectory statistical methods was estimated for particular species and at specified receptor locations. We have obtained a more general statistical estimation of the accuracy of source reconstruction and have found optimum conditions to reconstruct source distributions of atmospheric trace substances. Only virtual pollutants of the primary type were considered. In real world experiments, TSMs are intended for application to a priori unknown sources. Therefore, the accuracy of TSMs has to be tested with all possible spatial distributions of sources. An ensemble of geographical distributions of virtual sources was generated. Spearman s rank order correlation coefficient between spatial distributions of the known virtual and the reconstructed sources was taken to be a quantitative measure of the accuracy. Statistical estimates of the mean correlation coefficient and a range of the most probable values of correlation coefficients were obtained. All the TSMs that were considered here showed similar close results. The maximum of the ratio of the mean correlation to the width of the correlation interval containing the most probable correlation values determines the optimum conditions for reconstruction. An optimal geographical domain roughly coincides with the area supplying most of the substance to the receptor. The optimal domain s size is dependent on the substance decay time. Under optimum reconstruction conditions, the mean correlation coefficients can reach 0.70 0.75. The boundaries of the interval with the most probable correlation values are 0.6 0.9 for the decay time of 240 h and 0.5 0.95 for the decay time of 12 h. The best results of source reconstruction can be expected for the trace substances with a decay time on the order of several days. Although the methods considered in this paper do not guarantee high accuracy they are computationally simple and fast. Using the TSMs in optimum conditions and taking into account the range of uncertainties, one can obtain a first hint on potential source areas.

  9. Initial Ship Design Using a Pearson Correlation Coefficient and Artificial Intelligence Techniques

    NASA Astrophysics Data System (ADS)

    Moon, Byung Young; Kim, Soo Young; Kang, Gyung Ju

    In this paper we analyzed correlation between geometrical character and resistance, and effective horse power by using Pearson correlation coefficient which is one of the data mining methods. Also we made input data to ship's geometrical character which has strong correlation with output data. We calculated effective horse power and resistance by using Neuro-Fuzzy system. To verify the calculation, 9 of 11 container ships' data were improved as data of Neuro-Fuzzy system and the others were improved as verification data. After analyzing rate of error between existing data and calculation data, we concluded that calculation data have sound agreement with existing data.

  10. [Fractal dimension--a new EEG-based method of assessing the depth of anaesthesia].

    PubMed

    Willand, Monika; Rudner, Robert; Olejarczyk, Elzbieta; Wartak, Magdalena; Marciniak, Radosław; Stasiowski, Michał; Byrczek, Tomasz; Jałowiecki, Przemysław

    2008-01-01

    It has been suggested that analysis of the EEG signal using the fractal dimension method may be useful for assessment of depth of anaesthesia. Thirty ASA I and II patients, scheduled for elective surgery under general anaesthesia were induced with midazolam, fentanyl and propofol and paralyzed with rocuronium or cis-atracurium. Clinical signs of the depth of anaesthesia were classified to one of five OAA/S levels. Standard vital parameters were observed and brain electrical activity was measured using the bispectral index (BIS) and burst suppression ratio (BSR). The EEG signal was recorded and processed postoperatively to calculate Higuchi's fractal dimension (FD). The latter was presented as a derivative: (D(F)-1) x 100. Mean correlation coefficients between OAA/S scale levels, and BIS and (D(F)-1) x 100 values, were respectively: 0.749+/-0.172 and 0.753+/-0.220. In 28 (93.3%) patients, BIS correlated well with FD (r=0.63+/-0.33). In twenty cases, burst suppression occurred and the correlation coefficient between BIS and DF was much lower (r=0.5860+/-3650), when compared to the group of 10 patients in which no burst suppression was detected (r=0.711+/-0.251). Appropriate correction was made using the following formula: D(FK)=D(F)-(D(F) x BSR). The mean correlation coefficient between BIS values and D(FK) in the BS group was r=0.629+/-0.331. In all cases, the mean correlation coefficient between (D(F)-1) x 100 and BIS was r=0.661+/-0.307 (p<0.001). The fractal dimension method can be regarded as equal to BIS for assessment of depth of anaesthesia.

  11. Statistical analysis and digital processing of the Mössbauer spectra

    NASA Astrophysics Data System (ADS)

    Prochazka, Roman; Tucek, Pavel; Tucek, Jiri; Marek, Jaroslav; Mashlan, Miroslav; Pechousek, Jiri

    2010-02-01

    This work is focused on using the statistical methods and development of the filtration procedures for signal processing in Mössbauer spectroscopy. Statistical tools for noise filtering in the measured spectra are used in many scientific areas. The use of a pure statistical approach in accumulated Mössbauer spectra filtration is described. In Mössbauer spectroscopy, the noise can be considered as a Poisson statistical process with a Gaussian distribution for high numbers of observations. This noise is a superposition of the non-resonant photons counting with electronic noise (from γ-ray detection and discrimination units), and the velocity system quality that can be characterized by the velocity nonlinearities. The possibility of a noise-reducing process using a new design of statistical filter procedure is described. This mathematical procedure improves the signal-to-noise ratio and thus makes it easier to determine the hyperfine parameters of the given Mössbauer spectra. The filter procedure is based on a periodogram method that makes it possible to assign the statistically important components in the spectral domain. The significance level for these components is then feedback-controlled using the correlation coefficient test results. The estimation of the theoretical correlation coefficient level which corresponds to the spectrum resolution is performed. Correlation coefficient test is based on comparison of the theoretical and the experimental correlation coefficients given by the Spearman method. The correctness of this solution was analyzed by a series of statistical tests and confirmed by many spectra measured with increasing statistical quality for a given sample (absorber). The effect of this filter procedure depends on the signal-to-noise ratio and the applicability of this method has binding conditions.

  12. Correlation of skeletal maturation stages determined by cervical vertebrae and hand-wrist evaluations.

    PubMed

    Flores-Mir, Carlos; Burgess, Corr A; Champney, Mitchell; Jensen, Robert J; Pitcher, Micheal R; Major, Paul W

    2006-01-01

    The aim of this study was to assess the correlation between the Fishman maturation prediction method (FMP) and the cervical vertebral maturation (CVM) method for skeletal maturation stage determination. Hand-wrist and lateral cephalograms from 79 subjects (52 females and 27 males) were used. Hand-wrist radiographs were analyzed using the FMP to determine skeletal maturation level (advanced, average, or delayed) and stage (relative position of the individual in the pubertal growth curve). Cervical vertebrae (C2, C3, and C4) outlines obtained from lateral cephalograms were analyzed using the CVM to determine skeletal maturation stage. Intraexaminer reliability (Intraclass correlation coefficient [ICC]) for both methods was calculated from 10 triplicate hand-wrist and lateral cephalograms from the same patients. An ICC coefficient of 0.985 for FMP and an ICC of 0.889 for CVM were obtained. A Spearman correlation value of 0.72 (P < .001) was found between the skeletal maturation stages of both methods. When the sample was subgrouped according to skeletal maturation level, the following correlation values were found: for early mature adolescents 0.73, for average mature adolescents 0.70, and for late mature adolescents 0.87. All these correlation values were statistically different from zero (P < .024). Correlation values between both skeletal maturation methods were moderately high. This may be high enough to use either of the methods indistinctively for research purposes but not for the assessment of individual patients. Skeletal level influences the correlation values and, therefore, it should be considered whenever possible.

  13. Interobserver Reliability of the Total Body Score System for Quantifying Human Decomposition.

    PubMed

    Dabbs, Gretchen R; Connor, Melissa; Bytheway, Joan A

    2016-03-01

    Several authors have tested the accuracy of the Total Body Score (TBS) method for quantifying decomposition, but none have examined the reliability of the method as a scoring system by testing interobserver error rates. Sixteen participants used the TBS system to score 59 observation packets including photographs and written descriptions of 13 human cadavers in different stages of decomposition (postmortem interval: 2-186 days). Data analysis used a two-way random model intraclass correlation in SPSS (v. 17.0). The TBS method showed "almost perfect" agreement between observers, with average absolute correlation coefficients of 0.990 and average consistency correlation coefficients of 0.991. While the TBS method may have sources of error, scoring reliability is not one of them. Individual component scores were examined, and the influences of education and experience levels were investigated. Overall, the trunk component scores were the least concordant. Suggestions are made to improve the reliability of the TBS method. © 2016 American Academy of Forensic Sciences.

  14. Fungible Correlation Matrices: A Method for Generating Nonsingular, Singular, and Improper Correlation Matrices for Monte Carlo Research.

    PubMed

    Waller, Niels G

    2016-01-01

    For a fixed set of standardized regression coefficients and a fixed coefficient of determination (R-squared), an infinite number of predictor correlation matrices will satisfy the implied quadratic form. I call such matrices fungible correlation matrices. In this article, I describe an algorithm for generating positive definite (PD), positive semidefinite (PSD), or indefinite (ID) fungible correlation matrices that have a random or fixed smallest eigenvalue. The underlying equations of this algorithm are reviewed from both algebraic and geometric perspectives. Two simulation studies illustrate that fungible correlation matrices can be profitably used in Monte Carlo research. The first study uses PD fungible correlation matrices to compare penalized regression algorithms. The second study uses ID fungible correlation matrices to compare matrix-smoothing algorithms. R code for generating fungible correlation matrices is presented in the supplemental materials.

  15. The relationship between the managerial skills and results of "performance evaluation "tool among nursing managers in teaching hospitals of Iran University of Medical Science.

    PubMed

    Isfahani, Haleh Mousavi; Aryankhesal, Aidin; Haghani, Hamid

    2014-09-25

    Performance of different organizations, such as hospitals is mainly influenced by their managers' performance. Nursing managers have an important role in hospital performance and their managerial skills can improve the quality of the services. Hence, the present study was conducted in order to assess the relationship between the managerial skills and the results of their performance evaluation in Teaching Hospitals of Iran University of Medical Science in 2013. The research used the cross sectional method in 2013. It was done by distributing a managerial skills assessment questionnaire, with close-ended questions in 5 choice Likert scale, among 181 managers and head nurses of hospitals of Iran university of Medical Sciences; among which 131 answered the questions. Another data collection tools was a forms to record evaluation marks from the personnel records. We used Pearson and Spearman correlation tests and SPSS for analysis and description (frequency, mean and standard deviation). Results showed that the managerial skills of the nursing mangers were fair (2.57 out of 5) and the results of the performance evaluation were in a good condition (98.44). The mangers' evaluation results and the managerial skills scores were not in a meaningful correlation (r=0.047 np=0.856). The research showed no correlation between different domains of managerial skills and the performance evaluation marks: decision making skills (r=0.074 and p=0.399), leadership (correlation coefficient 0.028 and p=0.654), motivation (correlation coefficient 0.118 and p=0.163), communication  (correlation coefficient 0.116 and p=0.122), systematic thinking  (correlation coefficient 0.028 and p=0.828), time management (correlation coefficient 0.077 and p=0.401) and strategic thinking  (correlation coefficient 0.041 and p=0.756). Lack of any correlation and relation between managers' managerial skills and their performance evaluation results shows need to a fundamental revision at managers' performance evaluation form.

  16. Long-range correlations improve understanding of the influence of network structure on contact dynamics.

    PubMed

    Peyrard, N; Dieckmann, U; Franc, A

    2008-05-01

    Models of infectious diseases are characterized by a phase transition between extinction and persistence. A challenge in contemporary epidemiology is to understand how the geometry of a host's interaction network influences disease dynamics close to the critical point of such a transition. Here we address this challenge with the help of moment closures. Traditional moment closures, however, do not provide satisfactory predictions close to such critical points. We therefore introduce a new method for incorporating longer-range correlations into existing closures. Our method is technically simple, remains computationally tractable and significantly improves the approximation's performance. Our extended closures thus provide an innovative tool for quantifying the influence of interaction networks on spatially or socially structured disease dynamics. In particular, we examine the effects of a network's clustering coefficient, as well as of new geometrical measures, such as a network's square clustering coefficients. We compare the relative performance of different closures from the literature, with or without our long-range extension. In this way, we demonstrate that the normalized version of the Bethe approximation-extended to incorporate long-range correlations according to our method-is an especially good candidate for studying influences of network structure. Our numerical results highlight the importance of the clustering coefficient and the square clustering coefficient for predicting disease dynamics at low and intermediate values of transmission rate, and demonstrate the significance of path redundancy for disease persistence.

  17. QSAR modeling of flotation collectors using principal components extracted from topological indices.

    PubMed

    Natarajan, R; Nirdosh, Inderjit; Basak, Subhash C; Mills, Denise R

    2002-01-01

    Several topological indices were calculated for substituted-cupferrons that were tested as collectors for the froth flotation of uranium. The principal component analysis (PCA) was used for data reduction. Seven principal components (PC) were found to account for 98.6% of the variance among the computed indices. The principal components thus extracted were used in stepwise regression analyses to construct regression models for the prediction of separation efficiencies (Es) of the collectors. A two-parameter model with a correlation coefficient of 0.889 and a three-parameter model with a correlation coefficient of 0.913 were formed. PCs were found to be better than partition coefficient to form regression equations, and inclusion of an electronic parameter such as Hammett sigma or quantum mechanically derived electronic charges on the chelating atoms did not improve the correlation coefficient significantly. The method was extended to model the separation efficiencies of mercaptobenzothiazoles (MBT) and aminothiophenols (ATP) used in the flotation of lead and zinc ores, respectively. Five principal components were found to explain 99% of the data variability in each series. A three-parameter equation with correlation coefficient of 0.985 and a two-parameter equation with correlation coefficient of 0.926 were obtained for MBT and ATP, respectively. The amenability of separation efficiencies of chelating collectors to QSAR modeling using PCs based on topological indices might lead to the selection of collectors for synthesis and testing from a virtual database.

  18. Turbulence in a gaseous hydrogen-liquid oxygen rocket combustion chamber

    NASA Technical Reports Server (NTRS)

    Lebas, J.; Tou, P.; Ohara, J.

    1975-01-01

    The intensity of turbulence and the Lagrangian correlation coefficient for a LOX-GH2 rocket combustion chamber was determined from experimental measurements of tracer gas diffusion. A combination of Taylor's turbulent diffusion theory and a numerical method for solving the conservation equations of fluid mechanics was used to calculate these quantities. Taylor's theory was extended to consider the inhomogeneity of the turbulence field in the axial direction of the combustion chamber, and an exponential function was used to represent the Lagrangian correlation coefficient. The results indicate that the value of the intensity of turbulence reaches a maximum of 14% at a location about 7" downstream from the injector. The Lagrangian correlation coefficient associated with this value is given by the above exponential expression where alpha = 10,000/sec.

  19. A novel method for effective diffusion coefficient measurement in gas diffusion media of polymer electrolyte fuel cells

    NASA Astrophysics Data System (ADS)

    Yang, Linlin; Sun, Hai; Fu, Xudong; Wang, Suli; Jiang, Luhua; Sun, Gongquan

    2014-07-01

    A novel method for measuring effective diffusion coefficient of porous materials is developed. The oxygen concentration gradient is established by an air-breathing proton exchange membrane fuel cell (PEMFC). The porous sample is set in a sample holder located in the cathode plate of the PEMFC. At a given oxygen flux, the effective diffusion coefficients are related to the difference of oxygen concentration across the samples, which can be correlated with the differences of the output voltage of the PEMFC with and without inserting the sample in the cathode plate. Compared to the conventional electrical conductivity method, this method is more reliable for measuring non-wetting samples.

  20. Marine Targets Classification in PolInSAR Data

    NASA Astrophysics Data System (ADS)

    Chen, Peng; Yang, Jingsong; Ren, Lin

    2014-11-01

    In this paper, marine stationary targets and moving targets are studied by Pol-In-SAR data of Radarsat-2. A new method of stationary targets detection is proposed. The method get the correlation coefficient image of the In-SAR data, and using the histogram of correlation coefficient image. Then, A Constant False Alarm Rate (CFAR) algorithm and The Probabilistic Neural Network model are imported to detect stationary targets. To find the moving targets, Azimuth Ambiguity is show as an important feature. We use the length of azimuth ambiguity to get the target's moving direction and speed. Make further efforts, Targets classification is studied by rebuild the surface elevation of marine targets.

  1. Marine Targets Classification in PolInSAR Data

    NASA Astrophysics Data System (ADS)

    Chen, Peng; Yang, Jingsong; Ren, Lin

    2014-11-01

    In this paper, marine stationary targets and moving targets are studied by Pol-In-SAR data of Radarsat-2. A new method of stationary targets detection is proposed. The method get the correlation coefficient image of the In-SAR data, and using the histogram of correlation coefficient image. Then , A Constant False Alarm Rate (CFAR) algorithm and The Probabilistic Neural Network model are imported to detect stationary targets. To find the moving targets, Azimuth Ambiguity is show as an important feature. We use the length of azimuth ambiguity to get the target's moving direction and speed. Make further efforts, Targets classification is studied by rebuild the surface elevation of marine targets.

  2. Mastication noise reduction method for fully implantable hearing aid using piezo-electric sensor.

    PubMed

    Na, Sung Dae; Lee, Gihyoun; Wei, Qun; Seong, Ki Woong; Cho, Jin Ho; Kim, Myoung Nam

    2017-07-20

    Fully implantable hearing devices (FIHDs) can be affected by generated biomechanical noise such as mastication noise. To reduce the mastication noise using a piezo-electric sensor, the mastication noise is measured with the piezo-electric sensor, and noise reduction is practiced by the energy difference. For the experiment on mastication noise, a skull model was designed using artificial skull model and a piezo-electric sensor that can measure the vibration signals better than other sensors. A 1 kHz pure-tone sound through a standard speaker was applied to the model while the lower jawbone of the model was moved in a masticatory fashion. The correlation coefficients and signal-to-noise ratio (SNR) before and after application of the proposed method were compared. It was found that the signal-to-noise ratio and correlation coefficients increased by 4.48 dB and 0.45, respectively. The mastication noise is measured by piezo-electric sensor as the mastication noise that occurred during vibration. In addition, the noise was reduced by using the proposed method in conjunction with MATLAB. In order to confirm the performance of the proposed method, the correlation coefficients and signal-to-noise ratio before and after signal processing were calculated. In the future, an implantable microphone for real-time processing will be developed.

  3. Data Mining Methods Applied to Flight Operations Quality Assurance Data: A Comparison to Standard Statistical Methods

    NASA Technical Reports Server (NTRS)

    Stolzer, Alan J.; Halford, Carl

    2007-01-01

    In a previous study, multiple regression techniques were applied to Flight Operations Quality Assurance-derived data to develop parsimonious model(s) for fuel consumption on the Boeing 757 airplane. The present study examined several data mining algorithms, including neural networks, on the fuel consumption problem and compared them to the multiple regression results obtained earlier. Using regression methods, parsimonious models were obtained that explained approximately 85% of the variation in fuel flow. In general data mining methods were more effective in predicting fuel consumption. Classification and Regression Tree methods reported correlation coefficients of .91 to .92, and General Linear Models and Multilayer Perceptron neural networks reported correlation coefficients of about .99. These data mining models show great promise for use in further examining large FOQA databases for operational and safety improvements.

  4. Correlation among chronologic age, skeletal maturity, and dental age.

    PubMed

    Sukhia, Rashna H; Fida, Mubassar

    2010-01-01

    To determine the correlation among chronologic age, skeletal maturity, and dental age in reference to both sexes. In 380 subjects (147 males and 233 females) between 7 and 17 years of age, skeletal maturity was assessed using the cervical vertebral maturation stages described by Baccetti et al. Dental age was determined using the Demirjian method. The correlation between skeletal maturity and chronologic age on one side and between skeletal maturity and dental age on the other was assessed with Spearman rank correlation coefficients. Pearson correlation coefficients were used to assess the correlation between chronologic and dental age. For both sexes, significant correlations among chronologic age, skeletal maturity, and dental age were found. The mandibular first premolar had the highest correlation with skeletal maturation in both sexes. As skeletal maturity and dental age are significantly correlated, tooth development may be used to assess a patient's skeletal maturity at an early age. © 2011 BY QUINTESSENCE PUBLISHING CO, INC.

  5. Influence of structure properties on protein-protein interactions-QSAR modeling of changes in diffusion coefficients.

    PubMed

    Bauer, Katharina Christin; Hämmerling, Frank; Kittelmann, Jörg; Dürr, Cathrin; Görlich, Fabian; Hubbuch, Jürgen

    2017-04-01

    Information about protein-protein interactions provides valuable knowledge about the phase behavior of protein solutions during the biopharmaceutical production process. Up to date it is possible to capture their overall impact by an experimentally determined potential of mean force. For the description of this potential, the second virial coefficient B22, the diffusion interaction parameter kD, the storage modulus G', or the diffusion coefficient D is applied. In silico methods do not only have the potential to predict these parameters, but also to provide deeper understanding of the molecular origin of the protein-protein interactions by correlating the data to the protein's three-dimensional structure. This methodology furthermore allows a lower sample consumption and less experimental effort. Of all in silico methods, QSAR modeling, which correlates the properties of the molecule's structure with the experimental behavior, seems to be particularly suitable for this purpose. To verify this, the study reported here dealt with the determination of a QSAR model for the diffusion coefficient of proteins. This model consisted of diffusion coefficients for six different model proteins at various pH values and NaCl concentrations. The generated QSAR model showed a good correlation between experimental and predicted data with a coefficient of determination R2 = 0.9 and a good predictability for an external test set with R2 = 0.91. The information about the properties affecting protein-protein interactions present in solution was in agreement with experiment and theory. Furthermore, the model was able to give a more detailed picture of the protein properties influencing the diffusion coefficient and the acting protein-protein interactions. Biotechnol. Bioeng. 2017;114: 821-831. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Experimental determination of the turbulence in a liquid rocket combustion chamber

    NASA Technical Reports Server (NTRS)

    Hara, J.; Smith, L. O.; Partus, F. P.

    1972-01-01

    The intensity of turbulence and the Lagrangian correlation coefficient for a liquid rocket combustion chamber were determined experimentally using the tracer gas diffusion method. The results indicate that the turbulent diffusion process can be adequately modeled by the one-dimensional Taylor theory; however, the numerical values show significant disagreement with previously accepted values. The intensity of turbulence is higher by a factor of about two, while the Lagrangian correlation coefficient which was assumed to be unity in the past is much less than unity.

  7. Cross-correlation analysis between Chinese TF contracts and treasury ETF based on high-frequency data

    NASA Astrophysics Data System (ADS)

    Zhou, Yu; Chen, Shi

    2016-02-01

    In this paper, we investigate the high-frequency cross-correlation relationship between Chinese treasury futures contracts and treasury ETF. We analyze the logarithmic return of these two price series, from which we can conclude that both return series are not normally distributed and the futures markets have greater volatility. We find significant cross-correlation between these two series. We further confirm the relationship using the DCCA coefficient and the DMCA coefficient. We quantify the long-range cross-correlation with DCCA method, and we further show that the relationship is multifractal. An arbitrage algorithm based on DFA regression with stable return is proposed in the last part.

  8. Further Examination of the Reliability of the Modified Rathus Assertiveness Schedule.

    ERIC Educational Resources Information Center

    Del Greco, Linda; And Others

    1986-01-01

    Examined the reliability of the 30-item Modified Rathus Assertiveness Schedule (MRAS) using the test-retest method over a three-week period. The MRAS yielded correlations of .74 using the Pearson product and Spearman Brown correlation coefficient. Correlations for males yielded .77 and .72. For females correlations for both tests were .72.…

  9. Implementations of geographically weighted lasso in spatial data with multicollinearity (Case study: Poverty modeling of Java Island)

    NASA Astrophysics Data System (ADS)

    Setiyorini, Anis; Suprijadi, Jadi; Handoko, Budhi

    2017-03-01

    Geographically Weighted Regression (GWR) is a regression model that takes into account the spatial heterogeneity effect. In the application of the GWR, inference on regression coefficients is often of interest, as is estimation and prediction of the response variable. Empirical research and studies have demonstrated that local correlation between explanatory variables can lead to estimated regression coefficients in GWR that are strongly correlated, a condition named multicollinearity. It later results on a large standard error on estimated regression coefficients, and, hence, problematic for inference on relationships between variables. Geographically Weighted Lasso (GWL) is a method which capable to deal with spatial heterogeneity and local multicollinearity in spatial data sets. GWL is a further development of GWR method, which adds a LASSO (Least Absolute Shrinkage and Selection Operator) constraint in parameter estimation. In this study, GWL will be applied by using fixed exponential kernel weights matrix to establish a poverty modeling of Java Island, Indonesia. The results of applying the GWL to poverty datasets show that this method stabilizes regression coefficients in the presence of multicollinearity and produces lower prediction and estimation error of the response variable than GWR does.

  10. Repeatability and reproducibility of corneal thickness using SOCT Copernicus HR.

    PubMed

    Vidal, Silvia; Viqueira, Valentín; Mas, David; Domenech, Begoña

    2013-05-01

    The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (S(W)) and the within-subject coefficient of variation (C(W)). The level of agreement by Bland-Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  11. Measurements of the thermal coefficient of optical attenuation at different depth regions of in vivo human skins using optical coherence tomography: a pilot study

    PubMed Central

    Su, Ya; Yao, X. Steve; Li, Zhihong; Meng, Zhuo; Liu, Tiegen; Wang, Longzhi

    2015-01-01

    We present detailed measurement results of optical attenuation’s thermal coefficients (referenced to the temperature of the skin surface) in different depth regions of in vivo human forearm skins using optical coherence tomography (OCT). We first design a temperature control module with an integrated optical probe to precisely control the surface temperature of a section of human skin. We propose a method of using the correlation map to identify regions in the skin having strong correlations with the surface temperature of the skin and find that the attenuation coefficient in these regions closely follows the variation of the surface temperature without any hysteresis. We observe a negative thermal coefficient of attenuation in the epidermis. While in dermis, the slope signs of the thermal coefficient of attenuation are different at different depth regions for a particular subject, however, the depth regions with a positive (or negative) slope are different in different subjects. We further find that the magnitude of the thermal coefficient of attenuation coefficient is greater in epidermis than in dermis. We believe the knowledge of such thermal properties of skins is important for several noninvasive diagnostic applications, such as OCT glucose monitoring, and the method demonstrated in this paper is effective in studying the optical and biological properties in different regions of skin. PMID:25780740

  12. Diffusion and solubility coefficients determined by permeation and immersion experiments for organic solvents in HDPE geomembrane.

    PubMed

    Chao, Keh-Ping; Wang, Ping; Wang, Ya-Ting

    2007-04-02

    The chemical resistance of eight organic solvents in high density polyethylene (HDPE) geomembrane has been investigated using the ASTM F739 permeation method and the immersion test at different temperatures. The diffusion of the experimental organic solvents in HDPE geomembrane was non-Fickian kinetic, and the solubility coefficients can be consistent with the solubility parameter theory. The diffusion coefficients and solubility coefficients determined by the ASTM F739 method were significantly correlated to the immersion tests (p<0.001). The steady state permeation rates also showed a good agreement between ASTM F739 and immersion experiments (r(2)=0.973, p<0.001). Using a one-dimensional diffusion equation based on Fick's second law, the diffusion and solubility coefficients obtained by immersion test resulted in over estimates of the ASTM F739 permeation results. The modeling results indicated that the diffusion and solubility coefficients should be obtained using ASTM F739 method which closely simulates the practical application of HDPE as barriers in the field.

  13. Quality assessment of remote sensing image fusion using feature-based fourth-order correlation coefficient

    NASA Astrophysics Data System (ADS)

    Ma, Dan; Liu, Jun; Chen, Kai; Li, Huali; Liu, Ping; Chen, Huijuan; Qian, Jing

    2016-04-01

    In remote sensing fusion, the spatial details of a panchromatic (PAN) image and the spectrum information of multispectral (MS) images will be transferred into fused images according to the characteristics of the human visual system. Thus, a remote sensing image fusion quality assessment called feature-based fourth-order correlation coefficient (FFOCC) is proposed. FFOCC is based on the feature-based coefficient concept. Spatial features related to spatial details of the PAN image and spectral features related to the spectrum information of MS images are first extracted from the fused image. Then, the fourth-order correlation coefficient between the spatial and spectral features is calculated and treated as the assessment result. FFOCC was then compared with existing widely used indices, such as Erreur Relative Globale Adimensionnelle de Synthese, and quality assessed with no reference. Results of the fusion and distortion experiments indicate that the FFOCC is consistent with subjective evaluation. FFOCC significantly outperforms the other indices in evaluating fusion images that are produced by different fusion methods and that are distorted in spatial and spectral features by blurring, adding noise, and changing intensity. All the findings indicate that the proposed method is an objective and effective quality assessment for remote sensing image fusion.

  14. SPSS and SAS programs for comparing Pearson correlations and OLS regression coefficients.

    PubMed

    Weaver, Bruce; Wuensch, Karl L

    2013-09-01

    Several procedures that use summary data to test hypotheses about Pearson correlations and ordinary least squares regression coefficients have been described in various books and articles. To our knowledge, however, no single resource describes all of the most common tests. Furthermore, many of these tests have not yet been implemented in popular statistical software packages such as SPSS and SAS. In this article, we describe all of the most common tests and provide SPSS and SAS programs to perform them. When they are applicable, our code also computes 100 × (1 - α)% confidence intervals corresponding to the tests. For testing hypotheses about independent regression coefficients, we demonstrate one method that uses summary data and another that uses raw data (i.e., Potthoff analysis). When the raw data are available, the latter method is preferred, because use of summary data entails some loss of precision due to rounding.

  15. Comparison of nanoparticle diffusion using fluorescence correlation spectroscopy and differential dynamic microscopy within concentrated polymer solutions

    NASA Astrophysics Data System (ADS)

    Shokeen, Namita; Issa, Christopher; Mukhopadhyay, Ashis

    2017-12-01

    We studied the diffusion of nanoparticles (NPs) within aqueous entangled solutions of polyethylene oxide (PEO) by using two different optical techniques. Fluorescence correlation spectroscopy, a method widely used to investigate nanoparticle dynamics in polymer solution, was used to measure the long-time diffusion coefficient (D) of 25 nm radius particles within high molecular weight, Mw = 600 kg/mol PEO in water solutions. Differential dynamic microscopy (DDM) was used to determine the wave-vector dependent dynamics of NPs within the same polymer solutions. Our results showed good agreement between the two methods, including demonstration of normal diffusion and almost identical diffusion coefficients obtained by both techniques. The research extends the scope of DDM to study the dynamics and rheological properties of soft matter at a nanoscale. The measured diffusion coefficients followed a scaling theory, which can be explained by the coupling between polymer dynamics and NP motion.

  16. Comparative study of flow condensation in conventional and small diameter tubes

    NASA Astrophysics Data System (ADS)

    Mikielewicz, Dariusz; Andrzejczyk, Rafał

    2012-10-01

    Flow boiling and flow condensation are often regarded as two opposite or symmetrical phenomena. Their description however with a single correlation has yet to be suggested. In the case of flow boiling in minichannels there is mostly encountered the annular flow structure, where the bubble generation is not present. Similar picture holds for the case of inside tube condensation, where annular flow structure predominates. In such case the heat transfer coefficient is primarily dependent on the convective mechanism. In the paper a method developed earlier by the first author is applied to calculations of heat transfer coefficient for inside tube condensation. The method has been verified using experimental data from literature on several fluids in different microchannels and compared to three well established correlations for calculations of heat transfer coefficient in flow condensation. It clearly stems from the results presented here that the flow condensation can be modeled in terms of appropriately devised pressure drop.

  17. Cavitation in liquid cryogens. 3: Ogives

    NASA Technical Reports Server (NTRS)

    Hord, J.

    1973-01-01

    Experimental results for three, scaled, quarter-caliber ogives are given. Both desinent and developed cavity data, using liquid hydrogen and liquid nitrogen, are reported. The desinent data do not exhibit a consistent ogive size effect, but the developed cavity data were consistently influenced by ogive size; B-factor increases with increasing ogive diameter. The developed cavity data indicated that stable thermodynamic equilibrium exists throughout the vaporous cavities. These data were correlated by using the extended theory derived in NASA-CR-2156 (volume II of this report series). The new correlating parameter MTWO, improves data correlation for the ogives, hydrofoil, and venturi and appears attractive for future predictive applications. The cavitation coefficient and equipment size effects are shown to vary with specific equipment-fluid combinations. A method of estimating cavitation coefficient from knowledge of the noncavitating pressure coefficient is suggested.

  18. Extracting near-surface QL between 1-4 Hz from higher-order noise correlations in the Euroseistest area, Greece

    NASA Astrophysics Data System (ADS)

    Haendel, A.; Ohrnberger, M.; Krüger, F.

    2016-11-01

    Knowledge of the quality factor of near-surface materials is of fundamental interest in various applications. Attenuation can be very strong close to the surface and thus needs to be properly assessed. In recent years, several researchers have studied the retrieval of attenuation coefficients from the cross correlation of ambient seismic noise. Yet, the determination of exact amplitude information from noise-correlation functions is, in contrast to the extraction of traveltimes, not trivial. Most of the studies estimated attenuation coefficients on the regional scale and within the microseism band. In this paper, we investigate the possibility to derive attenuation coefficients from seismic noise at much shallower depths and higher frequencies (>1 Hz). The Euroseistest area in northern Greece offers ideal conditions to study quality factor retrieval from ambient noise for different rock types. Correlations are computed between the stations of a small scale array experiment (station spacings <2 km) that was carried out in the Euroseistest area in 2011. We employ the correlation of the coda of the correlation (C3) method instead of simple cross correlations to mitigate the effect of uneven noise source distributions on the correlation amplitude. Transient removal and temporal flattening are applied instead of 1-bit normalization in order to retain relative amplitudes. The C3 method leads to improved correlation results (higher signal-to-noise ratio and improved time symmetry) compared to simple cross correlations. The C3 functions are rotated from the ZNE to the ZRT system and we focus on Love wave arrivals on the transverse component and on Love wave quality factors QL. The analysis is performed for selected stations being either situated on soft soil or on weathered rock. Phase slowness is extracted using a slant-stack method. Attenuation parameters are inferred by inspecting the relative amplitude decay of Love waves with increasing interstation distance. We observe that the attenuation coefficient γ and QL can be reliably extracted for stations situated on soft soil whereas the derivation of attenuation parameters is more problematic for stations that are located on weathered rock. The results are in acceptable conformance with theoretical Love wave attenuation curves that were computed using 1-D shear wave velocity and quality factor profiles from the Euroseistest area.

  19. Visualizing Similarity of Appearance by Arrangement of Cards

    PubMed Central

    Nakatsuji, Nao; Ihara, Hisayasu; Seno, Takeharu; Ito, Hiroshi

    2016-01-01

    This study proposes a novel method to extract the configuration of the psychological space by directly measuring subjects' similarity rating without computational work. Although multidimensional scaling (MDS) is well-known as a conventional method for extracting the psychological space, the method requires many pairwise evaluations. The times taken for evaluations increase in proportion to the square of the number of objects in MDS. The proposed method asks subjects to arrange cards on a poster sheet according to the degree of similarity of the objects. To compare the performance of the proposed method with the conventional one, we developed similarity maps of typefaces through the proposed method and through non-metric MDS. We calculated the trace correlation coefficient among all combinations of the configuration for both methods to evaluate the degree of similarity in the obtained configurations. The threshold value of trace correlation coefficient for statistically discriminating similar configuration was decided based on random data. The ratio of the trace correlation coefficient exceeding the threshold value was 62.0% so that the configurations of the typefaces obtained by the proposed method closely resembled those obtained by non-metric MDS. The required duration for the proposed method was approximately one third of the non-metric MDS's duration. In addition, all distances between objects in all the data for both methods were calculated. The frequency for the short distance in the proposed method was lower than that of the non-metric MDS so that a relatively small difference was likely to be emphasized among objects in the configuration by the proposed method. The card arrangement method we here propose, thus serves as a easier and time-saving tool to obtain psychological structures in the fields related to similarity of appearance. PMID:27242611

  20. Assessment of curing behavior of light-activated dental composites using intensity correlation based multiple reference optical coherence tomography.

    PubMed

    Dsouza, Roshan; Subhash, Hrebesh; Neuhaus, Kai; Kantamneni, Ramakrishna; McNamara, Paul M; Hogan, Josh; Wilson, Carol; Leahy, Martin

    2016-01-01

    Monitoring the curing kinetics of light-activated resin is a key area of research. These resins are used in restorative applications and particularly in dental applications. They can undergo volumetric shrinkage due to poor control of the depth dependent curing process, modulated by the intensity and duration of the curing light source. This often results in the formation of marginal gaps, causing pain and damage to the restoration site. In this study, we demonstrate the capabilities of a correlation method applied using a multiple references optical coherence tomography (MR-OCT) architecture to monitor the curing of the resin. A MR-OCT system is used in this study to monitor the curing of the resin. The system operates at the center wavelength of 1310 nm with an A-scan rate of 1200 A-scans per second. The axial and lateral resolution of the system is ∼13 μm and ∼27 μm. The method to determine the intensity correlation between adjacent B-frames is based on the Pearson correlation coefficient for a region of interest. Calculating the correlation coefficient for multiple B-frames related to the first B-frame at regular spaced time points, shows for a noncured resin a reduction of the correlation coefficient over time due to Brownian motion. The time constant of the reduction of the correlation value is a measure for the progress of the polymerization during LED light irradiation of the resin. The proposed approach is potentially a low-cost, powerful and unique optical imaging modality for measuring the curing behavior of dental resin and other resins, coatings, and adhesives in medical and industrial applications. To demonstrate the proposed method to monitor the curing process, a light-activated resin composite from GRADIA DIRECT ANTERIOR (GC Corporation, Japan) is studied. The curing time of resin was measured and monitored as a function of depth. The correlation coefficient method is highly sensitive to Brownian motion. The process of curing results in a change in intensity as measured by the MR-OCT signal and hence can be monitored using this method. These results show that MR-OCT has the potential to measure the curing time and monitor the curing process as a function of depth. Moreover, MR-OCT as a product has potential to be compact, low-cost and to fit into a smartphone. Using such a device for monitoring the curing of the resin will be suitable for dentists in stationary and mobile clinical settings. © 2015 Wiley Periodicals, Inc.

  1. Shrinkage regression-based methods for microarray missing value imputation.

    PubMed

    Wang, Hsiuying; Chiu, Chia-Chun; Wu, Yi-Ching; Wu, Wei-Sheng

    2013-01-01

    Missing values commonly occur in the microarray data, which usually contain more than 5% missing values with up to 90% of genes affected. Inaccurate missing value estimation results in reducing the power of downstream microarray data analyses. Many types of methods have been developed to estimate missing values. Among them, the regression-based methods are very popular and have been shown to perform better than the other types of methods in many testing microarray datasets. To further improve the performances of the regression-based methods, we propose shrinkage regression-based methods. Our methods take the advantage of the correlation structure in the microarray data and select similar genes for the target gene by Pearson correlation coefficients. Besides, our methods incorporate the least squares principle, utilize a shrinkage estimation approach to adjust the coefficients of the regression model, and then use the new coefficients to estimate missing values. Simulation results show that the proposed methods provide more accurate missing value estimation in six testing microarray datasets than the existing regression-based methods do. Imputation of missing values is a very important aspect of microarray data analyses because most of the downstream analyses require a complete dataset. Therefore, exploring accurate and efficient methods for estimating missing values has become an essential issue. Since our proposed shrinkage regression-based methods can provide accurate missing value estimation, they are competitive alternatives to the existing regression-based methods.

  2. A novel measure and significance testing in data analysis of cell image segmentation.

    PubMed

    Wu, Jin Chu; Halter, Michael; Kacker, Raghu N; Elliott, John T; Plant, Anne L

    2017-03-14

    Cell image segmentation (CIS) is an essential part of quantitative imaging of biological cells. Designing a performance measure and conducting significance testing are critical for evaluating and comparing the CIS algorithms for image-based cell assays in cytometry. Many measures and methods have been proposed and implemented to evaluate segmentation methods. However, computing the standard errors (SE) of the measures and their correlation coefficient is not described, and thus the statistical significance of performance differences between CIS algorithms cannot be assessed. We propose the total error rate (TER), a novel performance measure for segmenting all cells in the supervised evaluation. The TER statistically aggregates all misclassification error rates (MER) by taking cell sizes as weights. The MERs are for segmenting each single cell in the population. The TER is fully supported by the pairwise comparisons of MERs using 106 manually segmented ground-truth cells with different sizes and seven CIS algorithms taken from ImageJ. Further, the SE and 95% confidence interval (CI) of TER are computed based on the SE of MER that is calculated using the bootstrap method. An algorithm for computing the correlation coefficient of TERs between two CIS algorithms is also provided. Hence, the 95% CI error bars can be used to classify CIS algorithms. The SEs of TERs and their correlation coefficient can be employed to conduct the hypothesis testing, while the CIs overlap, to determine the statistical significance of the performance differences between CIS algorithms. A novel measure TER of CIS is proposed. The TER's SEs and correlation coefficient are computed. Thereafter, CIS algorithms can be evaluated and compared statistically by conducting the significance testing.

  3. Novel Spectrophotometric Method for the Quantitation of Urinary Xanthurenic Acid and Its Application in Identifying Individuals with Hyperhomocysteinemia Associated with Vitamin B6 Deficiency

    PubMed Central

    Chen, Chi-Fen; Liu, Tsan-Zon; Lan, Wu-Hsiang; Wu, Li-An; Tsai, Chin-Hung; Chiou, Jeng-Fong; Tsai, Li-Yu

    2013-01-01

    A novel spectrophotometric method for the quantification of urinary xanthurenic acid (XA) is described. The direct acid ferric reduction (DAFR) procedure was used to quantify XA after it was purified by a solid-phase extraction column. The linearity of proposed method extends from 2.5 to 100.0 mg/L. The method is precise, yielding day-to-day CVs for two pooled controls of 3.5% and 4.6%, respectively. Correlation studies with an established HPLC method and a fluorometric procedure showed correlation coefficients of 0.98 and 0.98, respectively. Interference from various urinary metabolites was insignificant. In a small-scale screening of elderly conducted at Penghu county in Taiwan (n = 80), we were able to identify a group of twenty individuals having hyperhomocysteinemia (>15 μmole/L). Three of them were found to be positive for XA as analyzed by the proposed method, which correlated excellently with the results of the activation coefficient method for RBC's AST/B6 functional test. These data confirm the usefulness of the proposed method for identifying urinary XA as an indicator of vitamin B6 deficiency-associated hyperhomocysteinemic condition. PMID:24151616

  4. Generalized Correlation Coefficient for Non-Parametric Analysis of Microarray Time-Course Data.

    PubMed

    Tan, Qihua; Thomassen, Mads; Burton, Mark; Mose, Kristian Fredløv; Andersen, Klaus Ejner; Hjelmborg, Jacob; Kruse, Torben

    2017-06-06

    Modeling complex time-course patterns is a challenging issue in microarray study due to complex gene expression patterns in response to the time-course experiment. We introduce the generalized correlation coefficient and propose a combinatory approach for detecting, testing and clustering the heterogeneous time-course gene expression patterns. Application of the method identified nonlinear time-course patterns in high agreement with parametric analysis. We conclude that the non-parametric nature in the generalized correlation analysis could be an useful and efficient tool for analyzing microarray time-course data and for exploring the complex relationships in the omics data for studying their association with disease and health.

  5. Comparison of aerodynamic coefficients obtained from theoretical calculations wind tunnel tests and flight tests data reduction for the alpha jet aircraft

    NASA Technical Reports Server (NTRS)

    Guiot, R.; Wunnenberg, H.

    1980-01-01

    The methods by which aerodynamic coefficients are determined and discussed. These include: calculations, wind tunnel experiments and experiments in flight for various prototypes of the Alpha Jet. A comparison of obtained results shows good correlation between expectations and in-flight test results.

  6. Behavior of R-Square for Pooled Data Sets.

    ERIC Educational Resources Information Center

    Adams, Arthur J.; Shiffler, Ronald E.

    1989-01-01

    New methods of analysis--equations and graphs for iso-r(sup 2) contours--were introduced and used to illustrate location effects for pooled data sets. The "r(sup 2)" is the coefficient of determination. Results are used to highlight imprecise statements in the literature about the behavior of the correlation coefficient for pooled data…

  7. Relationship of body mass index to percent body fat and waist circumference among schoolchildren in Japan - the influence of gender and obesity: a population-based cross-sectional study

    PubMed Central

    2010-01-01

    Background Although the correlation coefficient between body mass index (BMI) and percent body fat (%BF) or waist circumference (WC) has been reported, studies conducted among population-based schoolchildren to date have been limited in Japan, where %BF and WC are not usually measured in annual health examinations at elementary schools or junior high schools. The aim of the present study was to investigate the relationship of BMI to %BF and WC and to examine the influence of gender and obesity on these relationships among Japanese schoolchildren. Methods Subjects included 3,750 schoolchildren from the fourth and seventh grade in Ina-town, Saitama Prefecture, Japan between 2004 and 2008. Information about subject's age, sex, height, weight, %BF, and WC was collected from annual physical examinations. %BF was measured with a bipedal biometrical impedance analysis device. Obesity was defined by the following two criteria: the obese definition of the Centers for Disease Control and Prevention, and the definition of obesity for Japanese children. Pearson's correlation coefficients between BMI and %BF or WC were calculated separately for sex. Results Among fourth graders, the correlation coefficients between BMI and %BF were 0.74 for boys and 0.97 for girls, whereas those between BMI and WC were 0.94 for boys and 0.90 for girls. Similar results were observed in the analysis of seventh graders. The correlation coefficient between BMI and %BF varied by physique (obese or non-obese), with weaker correlations among the obese regardless of the definition of obesity; most correlation coefficients among obese boys were less than 0.5, whereas most correlations among obese girls were more than 0.7. On the other hand, the correlation coefficients between BMI and WC were more than 0.8 among boys and almost all coefficients were more than 0.7 among girls, regardless of physique. Conclusions BMI was positively correlated with %BF and WC among Japanese schoolchildren. The correlations could be influenced by obesity as well as by gender. Accordingly, it is essential to consider gender and obesity when using BMI as a surrogate for %BF and WC for epidemiological use. PMID:20716379

  8. A new correlation coefficient for bivariate time-series data

    NASA Astrophysics Data System (ADS)

    Erdem, Orhan; Ceyhan, Elvan; Varli, Yusuf

    2014-11-01

    The correlation in time series has received considerable attention in the literature. Its use has attained an important role in the social sciences and finance. For example, pair trading in finance is concerned with the correlation between stock prices, returns, etc. In general, Pearson’s correlation coefficient is employed in these areas although it has many underlying assumptions which restrict its use. Here, we introduce a new correlation coefficient which takes into account the lag difference of data points. We investigate the properties of this new correlation coefficient. We demonstrate that it is more appropriate for showing the direction of the covariation of the two variables over time. We also compare the performance of the new correlation coefficient with Pearson’s correlation coefficient and Detrended Cross-Correlation Analysis (DCCA) via simulated examples.

  9. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study

    PubMed Central

    Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.

    2016-01-01

    Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049

  10. Rapid Contour-based Segmentation for 18F-FDG PET Imaging of Lung Tumors by Using ITK-SNAP: Comparison to Expert-based Segmentation.

    PubMed

    Besson, Florent L; Henry, Théophraste; Meyer, Céline; Chevance, Virgile; Roblot, Victoire; Blanchet, Elise; Arnould, Victor; Grimon, Gilles; Chekroun, Malika; Mabille, Laurence; Parent, Florence; Seferian, Andrei; Bulifon, Sophie; Montani, David; Humbert, Marc; Chaumet-Riffaud, Philippe; Lebon, Vincent; Durand, Emmanuel

    2018-04-03

    Purpose To assess the performance of the ITK-SNAP software for fluorodeoxyglucose (FDG) positron emission tomography (PET) segmentation of complex-shaped lung tumors compared with an optimized, expert-based manual reference standard. Materials and Methods Seventy-six FDG PET images of thoracic lesions were retrospectively segmented by using ITK-SNAP software. Each tumor was manually segmented by six raters to generate an optimized reference standard by using the simultaneous truth and performance level estimate algorithm. Four raters segmented 76 FDG PET images of lung tumors twice by using ITK-SNAP active contour algorithm. Accuracy of ITK-SNAP procedure was assessed by using Dice coefficient and Hausdorff metric. Interrater and intrarater reliability were estimated by using intraclass correlation coefficients of output volumes. Finally, the ITK-SNAP procedure was compared with currently recommended PET tumor delineation methods on the basis of thresholding at 41% volume of interest (VOI; VOI 41 ) and 50% VOI (VOI 50 ) of the tumor's maximal metabolism intensity. Results Accuracy estimates for the ITK-SNAP procedure indicated a Dice coefficient of 0.83 (95% confidence interval: 0.77, 0.89) and a Hausdorff distance of 12.6 mm (95% confidence interval: 9.82, 15.32). Interrater reliability was an intraclass correlation coefficient of 0.94 (95% confidence interval: 0.91, 0.96). The intrarater reliabilities were intraclass correlation coefficients above 0.97. Finally, VOI 41 and VOI 50 accuracy metrics were as follows: Dice coefficient, 0.48 (95% confidence interval: 0.44, 0.51) and 0.34 (95% confidence interval: 0.30, 0.38), respectively, and Hausdorff distance, 25.6 mm (95% confidence interval: 21.7, 31.4) and 31.3 mm (95% confidence interval: 26.8, 38.4), respectively. Conclusion ITK-SNAP is accurate and reliable for active-contour-based segmentation of heterogeneous thoracic PET tumors. ITK-SNAP surpassed the recommended PET methods compared with ground truth manual segmentation. © RSNA, 2018.

  11. Correlation between National Influenza Surveillance Data and Google Trends in South Korea

    PubMed Central

    Jo, Min Woo; Shin, Soo-Yong; Lee, Jae Ho; Ryoo, Seoung Mok; Kim, Won Young; Seo, Dong-Woo

    2013-01-01

    Background In South Korea, there is currently no syndromic surveillance system using internet search data, including Google Flu Trends. The purpose of this study was to investigate the correlation between national influenza surveillance data and Google Trends in South Korea. Methods Our study was based on a publicly available search engine database, Google Trends, using 12 influenza-related queries, from September 9, 2007 to September 8, 2012. National surveillance data were obtained from the Korea Centers for Disease Control and Prevention (KCDC) influenza-like illness (ILI) and virologic surveillance system. Pearson's correlation coefficients were calculated to compare the national surveillance and the Google Trends data for the overall period and for 5 influenza seasons. Results The correlation coefficient between the KCDC ILI and virologic surveillance data was 0.72 (p<0.05). The highest correlation was between the Google Trends query of H1N1 and the ILI data, with a correlation coefficient of 0.53 (p<0.05), for the overall study period. When compared with the KCDC virologic data, the Google Trends query of bird flu had the highest correlation with a correlation coefficient of 0.93 (p<0.05) in the 2010-11 season. The following queries showed a statistically significant correlation coefficient compared with ILI data for three consecutive seasons: Tamiflu (r = 0.59, 0.86, 0.90, p<0.05), new flu (r = 0.64, 0.43, 0.70, p<0.05) and flu (r = 0.68, 0.43, 0.77, p<0.05). Conclusions In our study, we found that the Google Trends for certain queries using the survey on influenza correlated with national surveillance data in South Korea. The results of this study showed that Google Trends in the Korean language can be used as complementary data for influenza surveillance but was insufficient for the use of predictive models, such as Google Flu Trends. PMID:24339927

  12. American Orthopaedic Foot and Ankle Society ankle-hindfoot scale: A cross-cultural adaptation and validation study from Iran.

    PubMed

    Vosoughi, Amir Reza; Roustaei, Narges; Mahdaviazad, Hamideh

    2018-06-01

    The use of valid and reliable outcome rating scales is essential for evaluating the result of different treatments and interventions. The purposes of this study were to translate and culturally adapt the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale (AOFAS-AHFS) into Persian languages and evaluate its psychometric properties. Forward-backward translation and cultural adaptation method were used to develop Persian version of AOFAS-AHFS. From March to July 2016, one hundred consecutive patients with ankle and hindfoot injuries were included. Internal consistency and reproducibility were evaluated using Cronbach's alpha, Spearman's rank correlation coefficient and Intraclass correlation coefficient (ICC) respectively. Construct validity reported which compare the outcome rating scale measurements with Short Form-36 (SF-36), also convergent and discriminant validity evaluated using Spearman's rank correlation coefficient. Mean age (SD) of the patients was 41.95±13.45years. Cronbach's α coefficient, Spearman's rho and ICC values were 0.71, 0.89 and 0.90 respectively. Total score of AOFAS-AHFS and SF-36 domains has a correlation ranged between 0.17-0.55. Spearman's rank correlation coefficient of 0.4 was exceeded by all items with the exception of stability. The Spearman's rank correlation between each item in functional subscales with its own subscales was higher than the correlation between these items and other subscales. Persian version of AOFAS-AHFS provides additional reliable and valid instrument which can be used to assess broad range of patients with foot and ankle disorders that speaking in Persian. However, it seems that the original version of AOFAS-AHFS needs some revisions. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  13. Statistical procedures for evaluating daily and monthly hydrologic model predictions

    USGS Publications Warehouse

    Coffey, M.E.; Workman, S.R.; Taraba, J.L.; Fogle, A.W.

    2004-01-01

    The overall study objective was to evaluate the applicability of different qualitative and quantitative methods for comparing daily and monthly SWAT computer model hydrologic streamflow predictions to observed data, and to recommend statistical methods for use in future model evaluations. Statistical methods were tested using daily streamflows and monthly equivalent runoff depths. The statistical techniques included linear regression, Nash-Sutcliffe efficiency, nonparametric tests, t-test, objective functions, autocorrelation, and cross-correlation. None of the methods specifically applied to the non-normal distribution and dependence between data points for the daily predicted and observed data. Of the tested methods, median objective functions, sign test, autocorrelation, and cross-correlation were most applicable for the daily data. The robust coefficient of determination (CD*) and robust modeling efficiency (EF*) objective functions were the preferred methods for daily model results due to the ease of comparing these values with a fixed ideal reference value of one. Predicted and observed monthly totals were more normally distributed, and there was less dependence between individual monthly totals than was observed for the corresponding predicted and observed daily values. More statistical methods were available for comparing SWAT model-predicted and observed monthly totals. The 1995 monthly SWAT model predictions and observed data had a regression Rr2 of 0.70, a Nash-Sutcliffe efficiency of 0.41, and the t-test failed to reject the equal data means hypothesis. The Nash-Sutcliffe coefficient and the R r2 coefficient were the preferred methods for monthly results due to the ability to compare these coefficients to a set ideal value of one.

  14. Chronologic age and skeletal maturation of the cervical vertebrae and hand-wrist: is there a relationship?

    PubMed

    Uysal, Tancan; Ramoglu, Sabri Ilhan; Basciftci, Faruk Ayhan; Sari, Zafer

    2006-11-01

    The aims of this study were (1) to investigate the relationship between chronologic age and maturation of cervical vertebrae, (2) to identify the relationship between chronologic age and maturation stage evaluated by hand-wrist radiographs, and (3) to determine whether the maturation of cervical vertebrae correlates with maturation indicated by hand-wrist radiographs in a Turkish population. The samples were derived from lateral cephalometric and hand-wrist radiographs of 503 subjects (213 male, 290 female; ages, 5.3-24.1 years). Cervical vertebral development was evaluated by the method of Hassel and Farman. Skeletal maturation of each hand-wrist radiograph was determined according to the method described by Björk and Grave, and Brown's system. The Spearman rank-order correlation coefficients were estimated separately for males and females to measure the relationships among chronologic age, cervical vertebral maturation, and the skeletal maturation measured at the hand-wrist. The Spearman correlation coefficients were 0.72 (P <.001) between chronologic age and cervical vertebrae skeletal maturation, and 0.79 (P < .001) between chronologic age and maturation via hand-wrist radiographs. The correlation coefficient between hand-wrist and cervical-vertebrae maturation was 0.86 (P <.001). The cervical-vertebrae maturation stages are clinically useful maturity indicators of the pubertal growth period Turkish subjects.

  15. Asymptotic properties of Pearson's rank-variate correlation coefficient under contaminated Gaussian model.

    PubMed

    Ma, Rubao; Xu, Weichao; Zhang, Yun; Ye, Zhongfu

    2014-01-01

    This paper investigates the robustness properties of Pearson's rank-variate correlation coefficient (PRVCC) in scenarios where one channel is corrupted by impulsive noise and the other is impulsive noise-free. As shown in our previous work, these scenarios that frequently encountered in radar and/or sonar, can be well emulated by a particular bivariate contaminated Gaussian model (CGM). Under this CGM, we establish the asymptotic closed forms of the expectation and variance of PRVCC by means of the well known Delta method. To gain a deeper understanding, we also compare PRVCC with two other classical correlation coefficients, i.e., Spearman's rho (SR) and Kendall's tau (KT), in terms of the root mean squared error (RMSE). Monte Carlo simulations not only verify our theoretical findings, but also reveal the advantage of PRVCC by an example of estimating the time delay in the particular impulsive noise environment.

  16. Quantitative Structure-Activity Relationship of Insecticidal Activity of Benzyl Ether Diamidine Derivatives

    NASA Astrophysics Data System (ADS)

    Zhai, Mengting; Chen, Yan; Li, Jing; Zhou, Jun

    2017-12-01

    The molecular electrongativity distance vector (MEDV-13) was used to describe the molecular structure of benzyl ether diamidine derivatives in this paper, Based on MEDV-13, The three-parameter (M 3, M 15, M 47) QSAR model of insecticidal activity (pIC 50) for 60 benzyl ether diamidine derivatives was constructed by leaps-and-bounds regression (LBR) . The traditional correlation coefficient (R) and the cross-validation correlation coefficient (R CV ) were 0.975 and 0.971, respectively. The robustness of the regression model was validated by Jackknife method, the correlation coefficient R were between 0.971 and 0.983. Meanwhile, the independent variables in the model were tested to be no autocorrelation. The regression results indicate that the model has good robust and predictive capabilities. The research would provide theoretical guidance for the development of new generation of anti African trypanosomiasis drugs with efficiency and low toxicity.

  17. Simulation of speckle patterns with pre-defined correlation distributions.

    PubMed

    Song, Lipei; Zhou, Zhen; Wang, Xueyan; Zhao, Xing; Elson, Daniel S

    2016-03-01

    We put forward a method to easily generate a single or a sequence of fully developed speckle patterns with pre-defined correlation distribution by utilizing the principle of coherent imaging. The few-to-one mapping between the input correlation matrix and the correlation distribution between simulated speckle patterns is realized and there is a simple square relationship between the values of these two correlation coefficient sets. This method is demonstrated both theoretically and experimentally. The square relationship enables easy conversion from any desired correlation distribution. Since the input correlation distribution can be defined by a digital matrix or a gray-scale image acquired experimentally, this method provides a convenient way to simulate real speckle-related experiments and to evaluate data processing techniques.

  18. Simulation of speckle patterns with pre-defined correlation distributions

    PubMed Central

    Song, Lipei; Zhou, Zhen; Wang, Xueyan; Zhao, Xing; Elson, Daniel S.

    2016-01-01

    We put forward a method to easily generate a single or a sequence of fully developed speckle patterns with pre-defined correlation distribution by utilizing the principle of coherent imaging. The few-to-one mapping between the input correlation matrix and the correlation distribution between simulated speckle patterns is realized and there is a simple square relationship between the values of these two correlation coefficient sets. This method is demonstrated both theoretically and experimentally. The square relationship enables easy conversion from any desired correlation distribution. Since the input correlation distribution can be defined by a digital matrix or a gray-scale image acquired experimentally, this method provides a convenient way to simulate real speckle-related experiments and to evaluate data processing techniques. PMID:27231589

  19. A short note on jackknifing the concordance correlation coefficient.

    PubMed

    Feng, Dai; Baumgartner, Richard; Svetnik, Vladimir

    2014-02-10

    Lin's concordance correlation coefficient (CCC) is a very popular scaled index of agreement used in applied statistics. To obtain a confidence interval (CI) for the estimate of CCC, jackknifing was proposed and shown to perform well in simulation as well as in applications. However, a theoretical proof of the validity of the jackknife CI for the CCC has not been presented yet. In this note, we establish a sufficient condition for using the jackknife method to construct the CI for the CCC. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Validity of three clinical performance assessments of internal medicine clerks.

    PubMed

    Hull, A L; Hodder, S; Berger, B; Ginsberg, D; Lindheim, N; Quan, J; Kleinhenz, M E

    1995-06-01

    To analyze the construct validity of three methods to assess the clinical performances of internal medicine clerks. A multitrait-multimethod (MTMM) study was conducted at the Case Western Reserve University School of Medicine to determine the convergent and divergent validity of a clinical evaluation form (CEF) completed by faculty and residents, an objective structured clinical examination (OSCE), and the medicine subject test of the National Board of Medical Examiners. Three traits were involved in the analysis: clinical skills, knowledge, and personal characteristics. A correlation matrix was computed for 410 third-year students who completed the clerkship between August 1988 and July 1991. There was a significant (p < .01) convergence of the four correlations that assessed the same traits by using different methods. However, the four convergent correlations were of moderate magnitude (ranging from .29 to .47). Divergent validity was assessed by comparing the magnitudes of the convergence correlations with the magnitudes of correlations among unrelated assessments (i.e., different traits by different methods). Seven of nine possible coefficients were smaller than the convergent coefficients, suggesting evidence of divergent validity. A significant CEF method effect was identified. There was convergent validity and some evidence of divergent validity with a significant method effect. The findings were similar for correlations corrected for attenuation. Four conclusions were reached: (1) the reliability of the OSCE must be improved, (2) the CEF ratings must be redesigned to further discriminate among the specific traits assessed, (3) additional methods to assess personal characteristics must be instituted, and (4) several assessment methods should be used to evaluate individual student performances.

  1. Gaussian graphical modeling reconstructs pathway reactions from high-throughput metabolomics data

    PubMed Central

    2011-01-01

    Background With the advent of high-throughput targeted metabolic profiling techniques, the question of how to interpret and analyze the resulting vast amount of data becomes more and more important. In this work we address the reconstruction of metabolic reactions from cross-sectional metabolomics data, that is without the requirement for time-resolved measurements or specific system perturbations. Previous studies in this area mainly focused on Pearson correlation coefficients, which however are generally incapable of distinguishing between direct and indirect metabolic interactions. Results In our new approach we propose the application of a Gaussian graphical model (GGM), an undirected probabilistic graphical model estimating the conditional dependence between variables. GGMs are based on partial correlation coefficients, that is pairwise Pearson correlation coefficients conditioned against the correlation with all other metabolites. We first demonstrate the general validity of the method and its advantages over regular correlation networks with computer-simulated reaction systems. Then we estimate a GGM on data from a large human population cohort, covering 1020 fasting blood serum samples with 151 quantified metabolites. The GGM is much sparser than the correlation network, shows a modular structure with respect to metabolite classes, and is stable to the choice of samples in the data set. On the example of human fatty acid metabolism, we demonstrate for the first time that high partial correlation coefficients generally correspond to known metabolic reactions. This feature is evaluated both manually by investigating specific pairs of high-scoring metabolites, and then systematically on a literature-curated model of fatty acid synthesis and degradation. Our method detects many known reactions along with possibly novel pathway interactions, representing candidates for further experimental examination. Conclusions In summary, we demonstrate strong signatures of intracellular pathways in blood serum data, and provide a valuable tool for the unbiased reconstruction of metabolic reactions from large-scale metabolomics data sets. PMID:21281499

  2. [Study on objectively evaluating skin aging according to areas of skin texture].

    PubMed

    Shan, Gaixin; Gan, Ping; He, Ling; Sun, Lu; Li, Qiannan; Jiang, Zheng; He, Xiangqian

    2015-02-01

    Skin aging principles play important roles in skin disease diagnosis, the evaluation of skin cosmetic effect, forensic identification and age identification in sports competition, etc. This paper proposes a new method to evaluate the skin aging objectively and quantitatively by skin texture area. Firstly, the enlarged skin image was acquired. Then, the skin texture image was segmented by using the iterative threshold method, and the skin ridge image was extracted according to the watershed algorithm. Finally, the skin ridge areas of the skin texture were extracted. The experiment data showed that the average areas of skin ridges, of both men and women, had a good correlation with age (the correlation coefficient r of male was 0.938, and the correlation coefficient r of female was 0.922), and skin texture area and age regression curve showed that the skin texture area increased with age. Therefore, it is effective to evaluate skin aging objectively by the new method presented in this paper.

  3. A chemical risk ranking and scoring method for the selection of harmful substances to be specially controlled in occupational environments.

    PubMed

    Shin, Saemi; Moon, Hyung-Il; Lee, Kwon Seob; Hong, Mun Ki; Byeon, Sang-Hoon

    2014-11-20

    This study aimed to devise a method for prioritizing hazardous chemicals for further regulatory action. To accomplish this objective, we chose appropriate indicators and algorithms. Nine indicators from the Globally Harmonized System of Classification and Labeling of Chemicals were used to identify categories to which the authors assigned numerical scores. Exposure indicators included handling volume, distribution, and exposure level. To test the method devised by this study, sixty-two harmful substances controlled by the Occupational Safety and Health Act in Korea, including acrylamide, acrylonitrile, and styrene were ranked using this proposed method. The correlation coefficients between total score and each indicator ranged from 0.160 to 0.641, and those between total score and hazard indicators ranged from 0.603 to 0.641. The latter were higher than the correlation coefficients between total score and exposure indicators, which ranged from 0.160 to 0.421. Correlations between individual indicators were low (-0.240 to 0.376), except for those between handling volume and distribution (0.613), suggesting that each indicator was not strongly correlated. The low correlations between each indicator mean that the indicators and independent and were well chosen for prioritizing harmful chemicals. This method proposed by this study can improve the cost efficiency of chemical management as utilized in occupational regulatory systems.

  4. Equations of prediction for abdominal fat in brown egg-laying hens fed different diets.

    PubMed

    Souza, C; Jaimes, J J B; Gewehr, C E

    2017-06-01

    The objective was to use noninvasive measurements to formulate equations for predicting the abdominal fat weight of laying hens in a noninvasive manner. Hens were fed with different diets; the external body measurements of birds were used as regressors. We used 288 Hy-Line Brown laying hens, distributed in a completely randomized design in a factorial arrangement, submitted for 16 wk to 2 metabolizable energy levels (2,550 and 2,800 kcal/kg) and 3 levels of crude protein in the diet (150, 160, and 170 g/kg), totaling 6 treatments, with 48 hens each. Sixteen hens per treatment of 92 wk age were utilized to evaluate body weight, bird length, tarsus and sternum, greater and lesser diameter of the tarsus, and abdominal fat weight, after slaughter. The equations were obtained by using measures evaluated with regressors through simple and multiple linear regression with the stepwise method of indirect elimination (backward), with P < 0.10 for all variables remaining in the model. The weight of abdominal fat as predicted by the equations and observed values for each bird were subjected to Pearson's correlation analysis. The equations generated by energy levels showed coefficients of determination of 0.50 and 0.74 for 2,800 and 2,550 kcal/kg of metabolizable energy, respectively, with correlation coefficients of 0.71 and 0.84, with a highly significant correlation between the calculated and observed values of abdominal fat. For protein levels of 150, 160, and 170 g/kg in the diet, it was possible to obtain coefficients of determination of 0.75, 0.57, and 0.61, with correlation coefficients of 0.86, 0.75, and 0.78, respectively. Regarding the general equation for predicting abdominal fat weight, the coefficient of determination was 0.62; the correlation coefficient was 0.79. The equations for predicting abdominal fat weight in laying hens, based on external measurements of the birds, showed positive coefficients of determination and correlation coefficients, thus allowing researchers to determine abdominal fat weight in vivo. © 2016 Poultry Science Association Inc.

  5. Tests of Hypotheses Arising In the Correlated Random Coefficient Model*

    PubMed Central

    Heckman, James J.; Schmierer, Daniel

    2010-01-01

    This paper examines the correlated random coefficient model. It extends the analysis of Swamy (1971), who pioneered the uncorrelated random coefficient model in economics. We develop the properties of the correlated random coefficient model and derive a new representation of the variance of the instrumental variable estimator for that model. We develop tests of the validity of the correlated random coefficient model against the null hypothesis of the uncorrelated random coefficient model. PMID:21170148

  6. Electromechanical imitator of antilock braking modes of wheels with pneumatic tire and its application for the runways friction coefficient measurement

    NASA Astrophysics Data System (ADS)

    Putov, A. V.; Kopichev, M. M.; Ignatiev, K. V.; Putov, V. V.; Stotckaia, A. D.

    2017-01-01

    In this paper it is considered a discussion of the technique that realizes a brand new method of runway friction coefficient measurement based upon the proposed principle of measuring wheel braking control for the imitation of antilock braking modes that are close to the real braking modes of the aircraft chassis while landing that are realized by the aircraft anti-skid systems. Also here is the description of the model of towed measuring device that realizes a new technique of runway friction coefficient measuring, based upon the measuring wheel braking control principle. For increasing the repeatability accuracy of electromechanical braking imitation system the sideslip (brake) adaptive control system is proposed. Based upon the Burkhard model and additive random processes several mathematical models were created that describes the friction coefficient arrangement along the airstrip with different qualitative adjectives. Computer models of friction coefficient measuring were designed and first in the world the research of correlation between the friction coefficient measuring results and shape variations, intensity and cycle frequency of the measuring wheel antilock braking modes. The sketch engineering documentation was designed and prototype of the latest generation measuring device is ready to use. The measuring device was tested on the autonomous electromechanical examination laboratory treadmill bench. The experiments approved effectiveness of method of imitation the antilock braking modes for solving the problem of correlation of the runway friction coefficient measuring.

  7. Predictive Validity of the Body Adiposity Index in Overweight and Obese Adults Using Dual-Energy X-ray Absorptiometry

    PubMed Central

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; García-Hermoso, Antonio; Triana-Reina, Hector Reynaldo

    2016-01-01

    The body adiposity index (BAI) is a recent anthropometric measure proven to be valid in predicting body fat percentage (BF%) in some populations. However, the results have been inconsistent across populations. This study was designed to verify the validity of BAI in predicting BF% in a sample of overweight/obese adults, using dual-energy X-ray absorptiometry (DEXA) as the reference method. A cross-sectional study was conducted in 48 participants (54% women, mean age 41.0 ± 7.3 years old). DEXA was used as the “gold standard” to determine BF%. Pearson’s correlation coefficient was used to evaluate the association between BAI and BF%, as assessed by DEXA. A paired sample t-test was used to test differences in mean BF% obtained with BAI and DEXA methods. To evaluate the concordance between BF% as measured by DEXA and as estimated by BAI, we used Lin’s concordance correlation coefficient and Bland–Altman agreement analysis. The correlation between BF% obtained by DEXA and that estimated by BAI was r = 0.844, p < 0.001. Paired t-test showed a significant mean difference in BF% between methods (BAI = 33.3 ± 6.2 vs. DEXA 39.0 ± 6.1; p < 0.001). The bias of the BAI was −6.0 ± 3.0 BF% (95% CI = −12.0 to 1.0), indicating that the BAI method significantly underestimated the BF% compared to the reference method. Lin’s concordance correlation coefficient was considered stronger (ρc = 0.923, 95% CI = 0.862 to 0.957). In obese adults, BAI presented low agreement with BF% measured by DEXA; therefore, BAI is not recommended for BF% prediction in this overweight/obese sample studied. PMID:27916871

  8. Network analysis of a financial market based on genuine correlation and threshold method

    NASA Astrophysics Data System (ADS)

    Namaki, A.; Shirazi, A. H.; Raei, R.; Jafari, G. R.

    2011-10-01

    A financial market is an example of an adaptive complex network consisting of many interacting units. This network reflects market’s behavior. In this paper, we use Random Matrix Theory (RMT) notion for specifying the largest eigenvector of correlation matrix as the market mode of stock network. For a better risk management, we clean the correlation matrix by removing the market mode from data and then construct this matrix based on the residuals. We show that this technique has an important effect on correlation coefficient distribution by applying it for Dow Jones Industrial Average (DJIA). To study the topological structure of a network we apply the removing market mode technique and the threshold method to Tehran Stock Exchange (TSE) as an example. We show that this network follows a power-law model in certain intervals. We also show the behavior of clustering coefficients and component numbers of this network for different thresholds. These outputs are useful for both theoretical and practical purposes such as asset allocation and risk management.

  9. Hierarchical multivariate covariance analysis of metabolic connectivity.

    PubMed

    Carbonell, Felix; Charil, Arnaud; Zijdenbos, Alex P; Evans, Alan C; Bedell, Barry J

    2014-12-01

    Conventional brain connectivity analysis is typically based on the assessment of interregional correlations. Given that correlation coefficients are derived from both covariance and variance, group differences in covariance may be obscured by differences in the variance terms. To facilitate a comprehensive assessment of connectivity, we propose a unified statistical framework that interrogates the individual terms of the correlation coefficient. We have evaluated the utility of this method for metabolic connectivity analysis using [18F]2-fluoro-2-deoxyglucose (FDG) positron emission tomography (PET) data from the Alzheimer's Disease Neuroimaging Initiative (ADNI) study. As an illustrative example of the utility of this approach, we examined metabolic connectivity in angular gyrus and precuneus seed regions of mild cognitive impairment (MCI) subjects with low and high β-amyloid burdens. This new multivariate method allowed us to identify alterations in the metabolic connectome, which would not have been detected using classic seed-based correlation analysis. Ultimately, this novel approach should be extensible to brain network analysis and broadly applicable to other imaging modalities, such as functional magnetic resonance imaging (MRI).

  10. A framework for combining multiple soil moisture retrievals based on maximizing temporal correlation

    NASA Astrophysics Data System (ADS)

    Kim, Seokhyeon; Parinussa, Robert M.; Liu, Yi. Y.; Johnson, Fiona M.; Sharma, Ashish

    2015-08-01

    A method for combining two microwave satellite soil moisture products by maximizing the temporal correlation with a reference data set has been developed. The method was applied to two global soil moisture data sets, Japan Aerospace Exploration Agency (JAXA) and Land Parameter Retrieval Model (LPRM), retrieved from the Advanced Microwave Scanning Radiometer 2 observations for the period 2012-2014. A global comparison revealed superior results of the combined product compared to the individual products against the reference data set of ERA-Interim volumetric water content. The global mean temporal correlation coefficient of the combined product with this reference was 0.52 which outperforms the individual JAXA (0.35) as well as the LPRM (0.45) product. Additionally, the performance was evaluated against in situ observations from the International Soil Moisture Network. The combined data set showed a significant improvement in temporal correlation coefficients in the validation compared to JAXA and minor improvements for the LPRM product.

  11. The coefficient of determination R2 and intra-class correlation coefficient from generalized linear mixed-effects models revisited and expanded.

    PubMed

    Nakagawa, Shinichi; Johnson, Paul C D; Schielzeth, Holger

    2017-09-01

    The coefficient of determination R 2 quantifies the proportion of variance explained by a statistical model and is an important summary statistic of biological interest. However, estimating R 2 for generalized linear mixed models (GLMMs) remains challenging. We have previously introduced a version of R 2 that we called [Formula: see text] for Poisson and binomial GLMMs, but not for other distributional families. Similarly, we earlier discussed how to estimate intra-class correlation coefficients (ICCs) using Poisson and binomial GLMMs. In this paper, we generalize our methods to all other non-Gaussian distributions, in particular to negative binomial and gamma distributions that are commonly used for modelling biological data. While expanding our approach, we highlight two useful concepts for biologists, Jensen's inequality and the delta method, both of which help us in understanding the properties of GLMMs. Jensen's inequality has important implications for biologically meaningful interpretation of GLMMs, whereas the delta method allows a general derivation of variance associated with non-Gaussian distributions. We also discuss some special considerations for binomial GLMMs with binary or proportion data. We illustrate the implementation of our extension by worked examples from the field of ecology and evolution in the R environment. However, our method can be used across disciplines and regardless of statistical environments. © 2017 The Author(s).

  12. Accuracy of contrast-enhanced spectral mammography for estimating residual tumor size after neoadjuvant chemotherapy in patients with breast cancer: a feasibility study

    PubMed Central

    Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano

    2017-01-01

    Objective To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). Materials and methods In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. Results The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). Conclusion CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent. PMID:28894329

  13. Dynamical behavior of the correlation between meteorological factors

    NASA Astrophysics Data System (ADS)

    You, Cheol-Hwan; Chang, Ki-Ho; Lee, Jun-Ho; Kim, Kyungsik

    2017-12-01

    We study the temporal and spatial variation characteristics of meteorological factors (temperature, humidity, and wind velocity) at a meteorological tower located on Bosung-gun of South Korea. We employ the detrended cross-correlation analysis (DCCA) method to extract the overall tendency of the hourly variation from data of meteorological factors. The relationships between meteorological factors are identified and quantified by using DCCA coefficients. From our results, we ascertain that the DCCA coefficient between temperature and humidity at time lag m = 24 has the smallest value at the height of 10 m of the measuring tower. Particularly, the DCCA coefficient between temperature and wind speed at time lag m = 24 has the largest value at a height of 10 m of the measuring tower

  14. Accuracy of a Radiological Evaluation Method for Thoracic and Lumbar Spinal Curvatures Using Spinous Processes.

    PubMed

    Marchetti, Bárbara V; Candotti, Cláudia T; Raupp, Eduardo G; Oliveira, Eduardo B C; Furlanetto, Tássia S; Loss, Jefferson F

    The purpose of this study was to assess a radiographic method for spinal curvature evaluation in children, based on spinous processes, and identify its normality limits. The sample consisted of 90 radiographic examinations of the spines of children in the sagittal plane. Thoracic and lumbar curvatures were evaluated using angular (apex angle [AA]) and linear (sagittal arrow [SA]) measurements based on the spinous processes. The same curvatures were also evaluated using the Cobb angle (CA) method, which is considered the gold standard. For concurrent validity (AA vs CA), Pearson's product-moment correlation coefficient, root-mean-square error, Pitman- Morgan test, and Bland-Altman analysis were used. For reproducibility (AA, SA, and CA), the intraclass correlation coefficient, standard error of measurement, and minimal detectable change measurements were used. A significant correlation was found between CA and AA measurements, as was a low root-mean-square error. The mean difference between the measurements was 0° for thoracic and lumbar curvatures, and the mean standard deviations of the differences were ±5.9° and 6.9°, respectively. The intraclass correlation coefficients of AA and SA were similar to or higher than the gold standard (CA). The standard error of measurement and minimal detectable change of the AA were always lower than the CA. This study determined the concurrent validity, as well as intra- and interrater reproducibility, of the radiographic measurements of kyphosis and lordosis in children. Copyright © 2017. Published by Elsevier Inc.

  15. Methods for assessing reliability and validity for a measurement tool: a case study and critique using the WHO haemoglobin colour scale.

    PubMed

    White, Sarah A; van den Broek, Nynke R

    2004-05-30

    Before introducing a new measurement tool it is necessary to evaluate its performance. Several statistical methods have been developed, or used, to evaluate the reliability and validity of a new assessment method in such circumstances. In this paper we review some commonly used methods. Data from a study that was conducted to evaluate the usefulness of a specific measurement tool (the WHO Colour Scale) is then used to illustrate the application of these methods. The WHO Colour Scale was developed under the auspices of the WHO to provide a simple portable and reliable method of detecting anaemia. This Colour Scale is a discrete interval scale, whereas the actual haemoglobin values it is used to estimate are on a continuous interval scale and can be measured accurately using electrical laboratory equipment. The methods we consider are: linear regression, correlation coefficients, paired t-tests plotting differences against mean values and deriving limits of agreement; kappa and weighted kappa statistics, sensitivity and specificity, an intraclass correlation coefficient and the repeatability coefficient. We note that although the definition and properties of each of these methods is well established inappropriate methods continue to be used in medical literature for assessing reliability and validity, as evidenced in the context of the evaluation of the WHO Colour Scale. Copyright 2004 John Wiley & Sons, Ltd.

  16. Characterization of Skin Friction Coefficient, and Relationship to Stratum Corneum Hydration in a Normal Chinese Population

    PubMed Central

    Zhu, Y.H.; Song, S.P.; Luo, W.; Elias, P.M.; Man, M.Q.

    2011-01-01

    Background and Objectives Studies have demonstrated that some cutaneous biophysical properties vary with age, gender and body sites. However, the characteristics of the skin friction coefficient in different genders and age groups have not yet been well established. In the present study, we assess the skin friction coefficient in a larger Chinese population. Methods A total of 633 subjects (300 males and 333 females) aged 0.15–79 years were enrolled. A Frictiometer® FR 770 and Corneometer® CM 825 (C&K MPA 5) were used to measure the skin friction coefficient and stratum corneum hydration, respectively, on the dorsal surface of the hand, the forehead and the canthus. Results In the females, the maximum skin friction coefficients on both the canthus and the dorsal hand skin were observed around the age of 40 years. In the males, the skin friction coefficient on the dorsal hand skin gradually increased from 0 to 40 years of age, and changed little afterward. Skin friction coefficients on some body sites were higher in females than in age-matched males in some age groups. On the canthus and the dorsal hand skin of females, a positive correlation was found between skin friction coefficient and stratum corneum hydration (p < 0.001 and p < 0.0001, respectively). In contrast, in males, the skin friction coefficient was positively correlated with stratum corneum hydration on the forehead and the dorsal hand skin (p < 0.05 and p < 0.0001, respectively). Conclusion The skin friction coefficient varies with age, gender and body site, and positively correlates with stratum corneum hydration on some body sites. PMID:21088455

  17. Research on the Fusion of Dependent Evidence Based on Rank Correlation Coefficient.

    PubMed

    Shi, Fengjian; Su, Xiaoyan; Qian, Hong; Yang, Ning; Han, Wenhua

    2017-10-16

    In order to meet the higher accuracy and system reliability requirements, the information fusion for multi-sensor systems is an increasing concern. Dempster-Shafer evidence theory (D-S theory) has been investigated for many applications in multi-sensor information fusion due to its flexibility in uncertainty modeling. However, classical evidence theory assumes that the evidence is independent of each other, which is often unrealistic. Ignoring the relationship between the evidence may lead to unreasonable fusion results, and even lead to wrong decisions. This assumption severely prevents D-S evidence theory from practical application and further development. In this paper, an innovative evidence fusion model to deal with dependent evidence based on rank correlation coefficient is proposed. The model first uses rank correlation coefficient to measure the dependence degree between different evidence. Then, total discount coefficient is obtained based on the dependence degree, which also considers the impact of the reliability of evidence. Finally, the discount evidence fusion model is presented. An example is illustrated to show the use and effectiveness of the proposed method.

  18. Revisiting crash spatial heterogeneity: A Bayesian spatially varying coefficients approach.

    PubMed

    Xu, Pengpeng; Huang, Helai; Dong, Ni; Wong, S C

    2017-01-01

    This study was performed to investigate the spatially varying relationships between crash frequency and related risk factors. A Bayesian spatially varying coefficients model was elaborately introduced as a methodological alternative to simultaneously account for the unstructured and spatially structured heterogeneity of the regression coefficients in predicting crash frequencies. The proposed method was appealing in that the parameters were modeled via a conditional autoregressive prior distribution, which involved a single set of random effects and a spatial correlation parameter with extreme values corresponding to pure unstructured or pure spatially correlated random effects. A case study using a three-year crash dataset from the Hillsborough County, Florida, was conducted to illustrate the proposed model. Empirical analysis confirmed the presence of both unstructured and spatially correlated variations in the effects of contributory factors on severe crash occurrences. The findings also suggested that ignoring spatially structured heterogeneity may result in biased parameter estimates and incorrect inferences, while assuming the regression coefficients to be spatially clustered only is probably subject to the issue of over-smoothness. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Research on the Fusion of Dependent Evidence Based on Rank Correlation Coefficient

    PubMed Central

    Su, Xiaoyan; Qian, Hong; Yang, Ning; Han, Wenhua

    2017-01-01

    In order to meet the higher accuracy and system reliability requirements, the information fusion for multi-sensor systems is an increasing concern. Dempster–Shafer evidence theory (D–S theory) has been investigated for many applications in multi-sensor information fusion due to its flexibility in uncertainty modeling. However, classical evidence theory assumes that the evidence is independent of each other, which is often unrealistic. Ignoring the relationship between the evidence may lead to unreasonable fusion results, and even lead to wrong decisions. This assumption severely prevents D–S evidence theory from practical application and further development. In this paper, an innovative evidence fusion model to deal with dependent evidence based on rank correlation coefficient is proposed. The model first uses rank correlation coefficient to measure the dependence degree between different evidence. Then, total discount coefficient is obtained based on the dependence degree, which also considers the impact of the reliability of evidence. Finally, the discount evidence fusion model is presented. An example is illustrated to show the use and effectiveness of the proposed method. PMID:29035341

  20. [Rapid prediction of annual ring density of Paulownia elongate standing tress using near infrared spectroscopy].

    PubMed

    Jiang, Ze-Hui; Wang, Yu-Rong; Fei, Ben-Hua; Fu, Feng; Hse, Chung-Yun

    2007-06-01

    Rapid prediction of annual ring density of Paulownia elongate standing trees using near infrared spectroscopy was studied. It was non-destructive to collect the samples for trees, that is, the wood cores 5 mm in diameter were unthreaded at the breast height of standing trees instead of fallen trees. Then the spectra data were collected by autoscan method of NIR. The annual ring density was determined by mercury immersion. And the models were made and analyzed by the partial least square (PLS) and full cross validation in the 350-2 500 nm wavelength range. The results showed that high coefficients were obtained between the annual ring and the NIR fitted data. The correlation coefficient of prediction model was 0.88 and 0.91 in the middle diameter and bigger diameter, respectively. Moreover, high coefficients of correlation were also obtained between annual ring density laboratory-determined and the NIR fitted data in the middle diameter of Paulownia elongate standing trees, the correlation coefficient of calibration model and prediction model were 0.90 and 0.83, and the standard errors of calibration (SEC) and standard errors of prediction(SEP) were 0.012 and 0.016, respectively. The method can simply, rapidly and non-destructively estimate the annual ring density of the Paulownia elongate standing trees close to the cutting age.

  1. Modified Regression Correlation Coefficient for Poisson Regression Model

    NASA Astrophysics Data System (ADS)

    Kaengthong, Nattacha; Domthong, Uthumporn

    2017-09-01

    This study gives attention to indicators in predictive power of the Generalized Linear Model (GLM) which are widely used; however, often having some restrictions. We are interested in regression correlation coefficient for a Poisson regression model. This is a measure of predictive power, and defined by the relationship between the dependent variable (Y) and the expected value of the dependent variable given the independent variables [E(Y|X)] for the Poisson regression model. The dependent variable is distributed as Poisson. The purpose of this research was modifying regression correlation coefficient for Poisson regression model. We also compare the proposed modified regression correlation coefficient with the traditional regression correlation coefficient in the case of two or more independent variables, and having multicollinearity in independent variables. The result shows that the proposed regression correlation coefficient is better than the traditional regression correlation coefficient based on Bias and the Root Mean Square Error (RMSE).

  2. A partitioned correlation function interaction approach for describing electron correlation in atoms

    NASA Astrophysics Data System (ADS)

    Verdebout, S.; Rynkun, P.; Jönsson, P.; Gaigalas, G.; Froese Fischer, C.; Godefroid, M.

    2013-04-01

    The traditional multiconfiguration Hartree-Fock (MCHF) and configuration interaction (CI) methods are based on a single orthonormal orbital basis. For atoms with many closed core shells, or complicated shell structures, a large orbital basis is needed to saturate the different electron correlation effects such as valence, core-valence and correlation within the core shells. The large orbital basis leads to massive configuration state function (CSF) expansions that are difficult to handle, even on large computer systems. We show that it is possible to relax the orthonormality restriction on the orbital basis and break down the originally very large calculations into a series of smaller calculations that can be run in parallel. Each calculation determines a partitioned correlation function (PCF) that accounts for a specific correlation effect. The PCFs are built on optimally localized orbital sets and are added to a zero-order multireference (MR) function to form a total wave function. The expansion coefficients of the PCFs are determined from a low dimensional generalized eigenvalue problem. The interaction and overlap matrices are computed using a biorthonormal transformation technique (Verdebout et al 2010 J. Phys. B: At. Mol. Phys. 43 074017). The new method, called partitioned correlation function interaction (PCFI), converges rapidly with respect to the orbital basis and gives total energies that are lower than the ones from ordinary MCHF and CI calculations. The PCFI method is also very flexible when it comes to targeting different electron correlation effects. Focusing our attention on neutral lithium, we show that by dedicating a PCF to the single excitations from the core, spin- and orbital-polarization effects can be captured very efficiently, leading to highly improved convergence patterns for hyperfine parameters compared with MCHF calculations based on a single orthogonal radial orbital basis. By collecting separately optimized PCFs to correct the MR function, the variational degrees of freedom in the relative mixing coefficients of the CSFs building the PCFs are inhibited. The constraints on the mixing coefficients lead to small off-sets in computed properties such as hyperfine structure, isotope shift and transition rates, with respect to the correct values. By (partially) deconstraining the mixing coefficients one converges to the correct limits and keeps the tremendous advantage of improved convergence rates that comes from the use of several orbital sets. Reducing ultimately each PCF to a single CSF with its own orbital basis leads to a non-orthogonal CI approach. Various perspectives of the new method are given.

  3. Deep pain sensitivity is correlated with oral-health-related quality of life but not with prosthetic factors in complete denture wearers

    PubMed Central

    COSTA, Yuri Martins; PORPORATTI, André Luís; HILGENBERG-SYDNEY, Priscila Brenner; BONJARDIM, Leonardo Rigoldi; CONTI, Paulo César Rodrigues

    2015-01-01

    ABSTRACT Low pressure Pain Threshold (PPT) is considered a risk factor for Temporomandibular Disorders (TMD) and is influenced by psychological variables. Objectives To correlate deep pain sensitivity of masticatory muscles with prosthetic factors and Oral-Health-Related Quality of Life (OHRQoL) in completely edentulous subjects. Material and Methods A total of 29 complete denture wearers were recruited. The variables were: a) Pressure Pain Threshold (PPT) of the masseter and temporalis; b) retention, stability, and tooth wear of dentures; c) Vertical Dimension of Occlusion (VDO); d) Oral Health Impact Profile (OHIP) adapted to orofacial pain. The Kolmogorov-Smirnov test, the Pearson Product-Moment correlation coefficient, the Spearman Rank correlation coefficient, the Point-Biserial correlation coefficient, and the Bonferroni correction (α=1%) were applied to the data. Results The mean age (standard deviation) of the participants was of 70.1 years (9.5) and 82% of them were females. There were no significant correlations with prosthetic factors, but significant negative correlations were found between the OHIP and the PPT of the anterior temporalis (r=-0.50, 95% CI-0.73 to 0.17, p=0.005). Discussion The deep pain sensitivity of masticatory muscles in complete dentures wearers is associated with OHRQoL, but not with prosthetic factors. PMID:26814457

  4. Differences Between Ward's and UPGMA Methods of Cluster Analysis: Implications for School Psychology.

    ERIC Educational Resources Information Center

    Hale, Robert L.; Dougherty, Donna

    1988-01-01

    Compared the efficacy of two methods of cluster analysis, the unweighted pair-groups method using arithmetic averages (UPGMA) and Ward's method, for students grouped on intelligence, achievement, and social adjustment by both clustering methods. Found UPGMA more efficacious based on output, on cophenetic correlation coefficients generated by each…

  5. Using beta coefficients to impute missing correlations in meta-analysis research: Reasons for caution.

    PubMed

    Roth, Philip L; Le, Huy; Oh, In-Sue; Van Iddekinge, Chad H; Bobko, Philip

    2018-06-01

    Meta-analysis has become a well-accepted method for synthesizing empirical research about a given phenomenon. Many meta-analyses focus on synthesizing correlations across primary studies, but some primary studies do not report correlations. Peterson and Brown (2005) suggested that researchers could use standardized regression weights (i.e., beta coefficients) to impute missing correlations. Indeed, their beta estimation procedures (BEPs) have been used in meta-analyses in a wide variety of fields. In this study, the authors evaluated the accuracy of BEPs in meta-analysis. We first examined how use of BEPs might affect results from a published meta-analysis. We then developed a series of Monte Carlo simulations that systematically compared the use of existing correlations (that were not missing) to data sets that incorporated BEPs (that impute missing correlations from corresponding beta coefficients). These simulations estimated ρ̄ (mean population correlation) and SDρ (true standard deviation) across a variety of meta-analytic conditions. Results from both the existing meta-analysis and the Monte Carlo simulations revealed that BEPs were associated with potentially large biases when estimating ρ̄ and even larger biases when estimating SDρ. Using only existing correlations often substantially outperformed use of BEPs and virtually never performed worse than BEPs. Overall, the authors urge a return to the standard practice of using only existing correlations in meta-analysis. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  6. Fast-GPU-PCC: A GPU-Based Technique to Compute Pairwise Pearson's Correlation Coefficients for Time Series Data-fMRI Study.

    PubMed

    Eslami, Taban; Saeed, Fahad

    2018-04-20

    Functional magnetic resonance imaging (fMRI) is a non-invasive brain imaging technique, which has been regularly used for studying brain’s functional activities in the past few years. A very well-used measure for capturing functional associations in brain is Pearson’s correlation coefficient. Pearson’s correlation is widely used for constructing functional network and studying dynamic functional connectivity of the brain. These are useful measures for understanding the effects of brain disorders on connectivities among brain regions. The fMRI scanners produce huge number of voxels and using traditional central processing unit (CPU)-based techniques for computing pairwise correlations is very time consuming especially when large number of subjects are being studied. In this paper, we propose a graphics processing unit (GPU)-based algorithm called Fast-GPU-PCC for computing pairwise Pearson’s correlation coefficient. Based on the symmetric property of Pearson’s correlation, this approach returns N ( N − 1 ) / 2 correlation coefficients located at strictly upper triangle part of the correlation matrix. Storing correlations in a one-dimensional array with the order as proposed in this paper is useful for further usage. Our experiments on real and synthetic fMRI data for different number of voxels and varying length of time series show that the proposed approach outperformed state of the art GPU-based techniques as well as the sequential CPU-based versions. We show that Fast-GPU-PCC runs 62 times faster than CPU-based version and about 2 to 3 times faster than two other state of the art GPU-based methods.

  7. Detection of tissue coagulation by decorrelation of ultrasonic echo signals in cavitation-enhanced high-intensity focused ultrasound treatment.

    PubMed

    Yoshizawa, Shin; Matsuura, Keiko; Takagi, Ryo; Yamamoto, Mariko; Umemura, Shin-Ichiro

    2016-01-01

    A noninvasive technique to monitor thermal lesion formation is necessary to ensure the accuracy and safety of high-intensity focused ultrasound (HIFU) treatment. The purpose of this study is to ultrasonically detect the tissue change due to thermal coagulation in the HIFU treatment enhanced by cavitation microbubbles. An ultrasound imaging probe transmitted plane waves at a center frequency of 4.5 MHz. Ultrasonic radio-frequency (RF) echo signals during HIFU exposure at a frequency of 1.2 MHz were acquired. Cross-correlation coefficients were calculated between in-phase and quadrature (IQ) data of two B-mode images with an interval time of 50 and 500 ms for the estimation of the region of cavitation and coagulation, respectively. Pathological examination of the coagulated tissue was also performed to compare with the corresponding ultrasonically detected coagulation region. The distribution of minimum hold cross-correlation coefficient between two sets of IQ data with 50-ms intervals was compared with a pulse inversion (PI) image. The regions with low cross-correlation coefficients approximately corresponded to those with high brightness in the PI image. The regions with low cross-correlation coefficients in 500-ms intervals showed a good agreement with those with significant change in histology. The results show that the regions of coagulation and cavitation could be ultrasonically detected as those with low cross-correlation coefficients between RF frames with certain intervals. This method will contribute to improve the safety and accuracy of the HIFU treatment enhanced by cavitation microbubbles.

  8. Estimation of the simple correlation coefficient.

    PubMed

    Shieh, Gwowen

    2010-11-01

    This article investigates some unfamiliar properties of the Pearson product-moment correlation coefficient for the estimation of simple correlation coefficient. Although Pearson's r is biased, except for limited situations, and the minimum variance unbiased estimator has been proposed in the literature, researchers routinely employ the sample correlation coefficient in their practical applications, because of its simplicity and popularity. In order to support such practice, this study examines the mean squared errors of r and several prominent formulas. The results reveal specific situations in which the sample correlation coefficient performs better than the unbiased and nearly unbiased estimators, facilitating recommendation of r as an effect size index for the strength of linear association between two variables. In addition, related issues of estimating the squared simple correlation coefficient are also considered.

  9. Reproducibility of abdominal fat assessment by ultrasound and computed tomography

    PubMed Central

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024

  10. Real external predictivity of QSAR models: how to evaluate it? Comparison of different validation criteria and proposal of using the concordance correlation coefficient.

    PubMed

    Chirico, Nicola; Gramatica, Paola

    2011-09-26

    The main utility of QSAR models is their ability to predict activities/properties for new chemicals, and this external prediction ability is evaluated by means of various validation criteria. As a measure for such evaluation the OECD guidelines have proposed the predictive squared correlation coefficient Q(2)(F1) (Shi et al.). However, other validation criteria have been proposed by other authors: the Golbraikh-Tropsha method, r(2)(m) (Roy), Q(2)(F2) (Schüürmann et al.), Q(2)(F3) (Consonni et al.). In QSAR studies these measures are usually in accordance, though this is not always the case, thus doubts can arise when contradictory results are obtained. It is likely that none of the aforementioned criteria is the best in every situation, so a comparative study using simulated data sets is proposed here, using threshold values suggested by the proponents or those widely used in QSAR modeling. In addition, a different and simple external validation measure, the concordance correlation coefficient (CCC), is proposed and compared with other criteria. Huge data sets were used to study the general behavior of validation measures, and the concordance correlation coefficient was shown to be the most restrictive. On using simulated data sets of a more realistic size, it was found that CCC was broadly in agreement, about 96% of the time, with other validation measures in accepting models as predictive, and in almost all the examples it was the most precautionary. The proposed concordance correlation coefficient also works well on real data sets, where it seems to be more stable, and helps in making decisions when the validation measures are in conflict. Since it is conceptually simple, and given its stability and restrictiveness, we propose the concordance correlation coefficient as a complementary, or alternative, more prudent measure of a QSAR model to be externally predictive.

  11. Correlation between hippocampal volumes and medial temporal lobe atrophy in patients with Alzheimer's disease

    PubMed Central

    Dhikav, Vikas; Duraiswamy, Sharmila; Anand, Kuljeet Singh

    2017-01-01

    Introduction: Hippocampus undergoes atrophy in patients with Alzheimer's disease (AD). Calculation of hippocampal volumes can be done by a variety of methods using T1-weighted images of magnetic resonance imaging (MRI) of the brain. Medial temporal lobes atrophy (MTL) can be rated visually using T1-weighted MRI brain images. The present study was done to see if any correlation existed between hippocampal volumes and visual rating scores of the MTL using Scheltens Visual Rating Method. Materials and Methods: We screened 84 subjects presented to the Department of Neurology of a Tertiary Care Hospital and enrolled forty subjects meeting the National Institute of Neurological and Communicative Disorders and Stroke, AD related Disease Association criteria. Selected patients underwent MRI brain and T1-weighted images in a plane perpendicular to long axis of hippocampus were obtained. Hippocampal volumes were calculated manually using a standard protocol. The calculated hippocampal volumes were correlated with Scheltens Visual Rating Method for Rating MTL. A total of 32 cognitively normal age-matched subjects were selected to see the same correlation in the healthy subjects as well. Sensitivity and specificity of both methods was calculated and compared. Results: There was an insignificant correlation between the hippocampal volumes and MTL rating scores in cognitively normal elderly (n = 32; Pearson Correlation coefficient = 0.16, P > 0.05). In the AD Group, there was a moderately strong correlation between measured hippocampal volumes and MTL Rating (Pearson's correlation coefficient = −0.54; P < 0.05. There was a moderately strong correlation between hippocampal volume and Mini-Mental Status Examination in the AD group. Manual delineation was superior compared to the visual method (P < 0.05). Conclusions: Good correlation was present between manual hippocampal volume measurements and MTL scores. Sensitivity and specificity of manual measurement of hippocampus was higher compared to visual rating scores for MTL in patients with AD. PMID:28298839

  12. Estimation of water absorption coefficient using the TDR method

    NASA Astrophysics Data System (ADS)

    Suchorab, Zbigniew; Majerek, Dariusz; Brzyski, Przemysław; Sobczuk, Henryk; Raczkowski, Andrzej

    2017-07-01

    Moisture accumulation and transport in the building barriers is an important feature that influences building performance, causing serious exploitation problems as increased energy use, mold and bacteria growth, decrease of indoor air parameters that may lead to sick building syndrome (SBS). One of the parameters that is used to describe moisture characteristic of the material is water absorption coefficient being the measure of capillary behavior of the material as a function of time and the surface area of the specimen. As usual it is determined using gravimetric methods according to EN 1925:1999 standard. In this article we demonstrate the possibility of determination of water absorption coefficient of autoclaved aerated concrete (AAC) using the Time Domain Reflectometry (TDR) method. TDR is an electric technique that had been adopted from soil science and can be successfully used for real-time monitoring of moisture transport in building materials and envelopes. Data achieved using TDR readouts show high correlation with standard method of moisture absorptivity coefficient determination.

  13. Test-Retest Reliability of the Salutogenic Wellness Promotion Scale (SWPS)

    ERIC Educational Resources Information Center

    Anderson, L. M.; Moore, J. B.; Hayden, B. M.; Becker, C. M.

    2014-01-01

    Objective: This study examined the temporal stability (i.e. test-retest reliability) of the Salutogenic Wellness Promotion Scale (SWPS) using intraclass correlation coefficients (ICC). Current intraclass results were also compared to previously published interclass correlations to support the use of the intraclass method for test-retest…

  14. The Covariance Adjustment Approaches for Combining Incomparable Cox Regressions Caused by Unbalanced Covariates Adjustment: A Multivariate Meta-Analysis Study.

    PubMed

    Dehesh, Tania; Zare, Najaf; Ayatollahi, Seyyed Mohammad Taghi

    2015-01-01

    Univariate meta-analysis (UM) procedure, as a technique that provides a single overall result, has become increasingly popular. Neglecting the existence of other concomitant covariates in the models leads to loss of treatment efficiency. Our aim was proposing four new approximation approaches for the covariance matrix of the coefficients, which is not readily available for the multivariate generalized least square (MGLS) method as a multivariate meta-analysis approach. We evaluated the efficiency of four new approaches including zero correlation (ZC), common correlation (CC), estimated correlation (EC), and multivariate multilevel correlation (MMC) on the estimation bias, mean square error (MSE), and 95% probability coverage of the confidence interval (CI) in the synthesis of Cox proportional hazard models coefficients in a simulation study. Comparing the results of the simulation study on the MSE, bias, and CI of the estimated coefficients indicated that MMC approach was the most accurate procedure compared to EC, CC, and ZC procedures. The precision ranking of the four approaches according to all above settings was MMC ≥ EC ≥ CC ≥ ZC. This study highlights advantages of MGLS meta-analysis on UM approach. The results suggested the use of MMC procedure to overcome the lack of information for having a complete covariance matrix of the coefficients.

  15. Progression of Mortality due to Diseases of the Circulatory System and Human Development Index in Rio de Janeiro Municipalities

    PubMed Central

    Soares, Gabriel Porto; Klein, Carlos Henrique; Silva, Nelson Albuquerque de Souza e; de Oliveira, Glaucia Maria Moraes

    2016-01-01

    Background Diseases of the circulatory system (DCS) are the major cause of death in Brazil and worldwide. Objective To correlate the compensated and adjusted mortality rates due to DCS in the Rio de Janeiro State municipalities between 1979 and 2010 with the Human Development Index (HDI) from 1970 onwards. Methods Population and death data were obtained in DATASUS/MS database. Mortality rates due to ischemic heart diseases (IHD), cerebrovascular diseases (CBVD) and DCS adjusted by using the direct method and compensated for ill-defined causes. The HDI data were obtained at the Brazilian Institute of Applied Research in Economics. The mortality rates and HDI values were correlated by estimating Pearson linear coefficients. The correlation coefficients between the mortality rates of census years 1991, 2000 and 2010 and HDI data of census years 1970, 1980 and 1991 were calculated with discrepancy of two demographic censuses. The linear regression coefficients were estimated with disease as the dependent variable and HDI as the independent variable. Results In recent decades, there was a reduction in mortality due to DCS in all Rio de Janeiro State municipalities, mainly because of the decline in mortality due to CBVD, which was preceded by an elevation in HDI. There was a strong correlation between the socioeconomic indicator and mortality rates. Conclusion The HDI progression showed a strong correlation with the decline in mortality due to DCS, signaling to the relevance of improvements in life conditions. PMID:27849263

  16. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    PubMed

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  17. Diffusion-weighted magnetic resonance imaging in the characterization of testicular germ cell neoplasms: Effect of ROI methods on apparent diffusion coefficient values and interobserver variability.

    PubMed

    Tsili, Athina C; Ntorkou, Alexandra; Astrakas, Loukas; Xydis, Vasilis; Tsampalas, Stavros; Sofikitis, Nikolaos; Argyropoulou, Maria I

    2017-04-01

    To evaluate the difference in apparent diffusion coefficient (ADC) measurements at diffusion-weighted (DW) magnetic resonance imaging of differently shaped regions-of-interest (ROIs) in testicular germ cell neoplasms (TGCNS), the diagnostic ability of differently shaped ROIs in differentiating seminomas from nonseminomatous germ cell neoplasms (NSGCNs) and the interobserver variability. Thirty-three TGCNs were retrospectively evaluated. Patients underwent MR examinations, including DWI on a 1.5-T MR system. Two observers measured mean tumor ADCs using four distinct ROI methods: round, square, freehand and multiple small, round ROIs. The interclass correlation coefficient was analyzed to assess interobserver variability. Statistical analysis was used to compare mean ADC measurements among observers, methods and histologic types. All ROI methods showed excellent interobserver agreement, with excellent correlation (P<0.001). Multiple, small ROIs provided the lower mean ADC in TGCNs. Seminomas had lower mean ADC compared to NSGCNs for each ROI method (P<0.001). Round ROI proved the most accurate method in characterizing TGCNS. Interobserver variability in ADC measurement is excellent, irrespective of the ROI shape. Multiple, small round ROIs and round ROI proved the more accurate methods for ADC measurement in the characterization of TGCNs and in the differentiation between seminomas and NSGCNs, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Detecting Pairwise Correlations in Spike Trains: An Objective Comparison of Methods and Application to the Study of Retinal Waves

    PubMed Central

    Eglen, Stephen J.

    2014-01-01

    Correlations in neuronal spike times are thought to be key to processing in many neural systems. Many measures have been proposed to summarize these correlations and of these the correlation index is widely used and is the standard in studies of spontaneous retinal activity. We show that this measure has two undesirable properties: it is unbounded above and confounded by firing rate. We list properties needed for a measure to fairly quantify and compare correlations and we propose a novel measure of correlation—the spike time tiling coefficient. This coefficient, the correlation index, and 33 other measures of correlation of spike times are blindly tested for the required properties on synthetic and experimental data. Based on this, we propose a measure (the spike time tiling coefficient) to replace the correlation index. To demonstrate the benefits of this measure, we reanalyze data from seven key studies, which previously used the correlation index to investigate the nature of spontaneous activity. We reanalyze data from β2(KO) and β2(TG) mutants, mutants lacking connexin isoforms, and also the age-dependent changes in wild-type and β2(KO) correlations. Reanalysis of the data using the proposed measure can significantly change the conclusions. It leads to better quantification of correlations and therefore better inference from the data. We hope that the proposed measure will have wide applications, and will help clarify the role of activity in retinotopic map formation. PMID:25339742

  19. A spatially adaptive total variation regularization method for electrical resistance tomography

    NASA Astrophysics Data System (ADS)

    Song, Xizi; Xu, Yanbin; Dong, Feng

    2015-12-01

    The total variation (TV) regularization method has been used to solve the ill-posed inverse problem of electrical resistance tomography (ERT), owing to its good ability to preserve edges. However, the quality of the reconstructed images, especially in the flat region, is often degraded by noise. To optimize the regularization term and the regularization factor according to the spatial feature and to improve the resolution of reconstructed images, a spatially adaptive total variation (SATV) regularization method is proposed. A kind of effective spatial feature indicator named difference curvature is used to identify which region is a flat or edge region. According to different spatial features, the SATV regularization method can automatically adjust both the regularization term and regularization factor. At edge regions, the regularization term is approximate to the TV functional to preserve the edges; in flat regions, it is approximate to the first-order Tikhonov (FOT) functional to make the solution stable. Meanwhile, the adaptive regularization factor determined by the spatial feature is used to constrain the regularization strength of the SATV regularization method for different regions. Besides, a numerical scheme is adopted for the implementation of the second derivatives of difference curvature to improve the numerical stability. Several reconstruction image metrics are used to quantitatively evaluate the performance of the reconstructed results. Both simulation and experimental results indicate that, compared with the TV (mean relative error 0.288, mean correlation coefficient 0.627) and FOT (mean relative error 0.295, mean correlation coefficient 0.638) regularization methods, the proposed SATV (mean relative error 0.259, mean correlation coefficient 0.738) regularization method can endure a relatively high level of noise and improve the resolution of reconstructed images.

  20. The Attenuation of Correlation Coefficients: A Statistical Literacy Issue

    ERIC Educational Resources Information Center

    Trafimow, David

    2016-01-01

    Much of the science reported in the media depends on correlation coefficients. But the size of correlation coefficients depends, in part, on the reliability with which the correlated variables are measured. Understanding this is a statistical literacy issue.

  1. Fluorescence background removal method for biological Raman spectroscopy based on empirical mode decomposition.

    PubMed

    Leon-Bejarano, Maritza; Dorantes-Mendez, Guadalupe; Ramirez-Elias, Miguel; Mendez, Martin O; Alba, Alfonso; Rodriguez-Leyva, Ildefonso; Jimenez, M

    2016-08-01

    Raman spectroscopy of biological tissue presents fluorescence background, an undesirable effect that generates false Raman intensities. This paper proposes the application of the Empirical Mode Decomposition (EMD) method to baseline correction. EMD is a suitable approach since it is an adaptive signal processing method for nonlinear and non-stationary signal analysis that does not require parameters selection such as polynomial methods. EMD performance was assessed through synthetic Raman spectra with different signal to noise ratio (SNR). The correlation coefficient between synthetic Raman spectra and the recovered one after EMD denoising was higher than 0.92. Additionally, twenty Raman spectra from skin were used to evaluate EMD performance and the results were compared with Vancouver Raman algorithm (VRA). The comparison resulted in a mean square error (MSE) of 0.001554. High correlation coefficient using synthetic spectra and low MSE in the comparison between EMD and VRA suggest that EMD could be an effective method to remove fluorescence background in biological Raman spectra.

  2. Assessment of a solid-phase reagent for urinary specific gravity determination.

    PubMed

    Chu, S Y; Sparks, D

    1984-02-01

    We have compared the specific gravity (S.G.) determined by the N-Multistix method with that obtained from the Total Solids (TS) meter. Overall, 88.7% of the specific gravity results obtained with the reagent strip method were within 0.005 of those obtained with the TS meter. There was a good correlation between the methods and there was no bias for the group means obtained by either method. A good correlation was also found between the S.G. on the strip and osmolality (correlation coefficient of 0.955). The results obtained with the reagent strip for urinary specific gravity therefore appear acceptable for routine laboratory purposes.

  3. Association between the accessibility to lethal methods and method-specific suicide rates: An ecological study in Taiwan.

    PubMed

    Lin, Jin-Jia; Lu, Tsung-Hsueh

    2006-07-01

    To examine the association between availability of lethal methods of suicide and method-specific suicide rates at the city/ county level in Taiwan. Age-adjusted and age-specific suicide rates of 23 cities/counties in Taiwan for the years 1999 to 2003 were calculated. Partial correlation coefficients were used to examine cross-sectional associations between independent variables, i.e., proportion of agricultural population and proportion of households living on the sixth floor or above, and suicide rates by different methods (poisoning by solids/liquids, jumping, and hanging) after adjusting for unemployment rates and prevalence of depression. The partial correlation coefficient was 0.77 (p < .001) for proportion of agricultural population with solids/liquids poisoning suicide rates. It was 0.73 (p < .001) for the proportion of households living on the sixth floor or above with suicide rates by jumping. Correlations between hanging suicide rates and proportion of agricultural population or between hanging suicide rates and proportion of households living on the sixth floor or above were not significant. The results showed strong positive associations between access to lethal methods and method-specific suicide rates. Controlling the availability of pesticides and fencing high buildings or installing window guards may be effective measures for suicide prevention.

  4. Development, reproducibility and validity of the food frequency questionnaire in the Poland arm of the Prospective Urban and Rural Epidemiological (PURE) study.

    PubMed

    Dehghan, M; Ilow, R; Zatonska, K; Szuba, A; Zhang, X; Mente, A; Regulska-Ilow, B

    2012-06-01

    A food frequency questionnaire (FFQ) is the most commonly used method in large epidemiological studies. The validation of an FFQ is essential for specific populations because foods are culture-dependent. The present study aimed to develop an FFQ and evaluate its validity and reproducibility in estimating the intake of nutrients in urban and rural areas of Poland. Adult participants (n = 146) in the Polish arm of the ongoing Prospective Urban and Rural Epidemiological (PURE) study completed FFQs on two occasions, as well as four 24-h dietary recalls (DRs) during a 12-month period. Correlation coefficients (r) and de-attenuated correlation coefficients between dietary recalls and both FFQs were calculated for selected macro- and micronutrients. Agreement between the two methods was evaluated by classification into quartiles and the Bland-Altman method. Reproducibility was assessed by the intra-class correlation coefficient (ICC). The final food list contained 134 food items. For urban participants, FFQ2 generally underestimated energy, protein and fat compared to the FFQ1 and mean of DRs. In rural areas, compared to DRs, both FFQs overestimated energy and macronutrients. For both urban and rural settings, de-attenuated correlation exceeded 0.4 for almost all nutrients and the exact agreement in quartile categorisation was >66%. When assessing repeatability, ICC varied from 0.39-0.63 in an urban setting and 0.19-0.45 in a rural setting. This 134-item FFQ has good validity and reproducibility in relation to the reference method and can be used to rank individuals based on their macro- and micronutrient intake. © 2012 The Authors. Journal of Human Nutrition and Dietetics © 2012 The British Dietetic Association Ltd.

  5. Bayesian power spectrum inference with foreground and target contamination treatment

    NASA Astrophysics Data System (ADS)

    Jasche, J.; Lavaux, G.

    2017-10-01

    This work presents a joint and self-consistent Bayesian treatment of various foreground and target contaminations when inferring cosmological power spectra and three-dimensional density fields from galaxy redshift surveys. This is achieved by introducing additional block-sampling procedures for unknown coefficients of foreground and target contamination templates to the previously presented ARES framework for Bayesian large-scale structure analyses. As a result, the method infers jointly and fully self-consistently three-dimensional density fields, cosmological power spectra, luminosity-dependent galaxy biases, noise levels of the respective galaxy distributions, and coefficients for a set of a priori specified foreground templates. In addition, this fully Bayesian approach permits detailed quantification of correlated uncertainties amongst all inferred quantities and correctly marginalizes over observational systematic effects. We demonstrate the validity and efficiency of our approach in obtaining unbiased estimates of power spectra via applications to realistic mock galaxy observations that are subject to stellar contamination and dust extinction. While simultaneously accounting for galaxy biases and unknown noise levels, our method reliably and robustly infers three-dimensional density fields and corresponding cosmological power spectra from deep galaxy surveys. Furthermore, our approach correctly accounts for joint and correlated uncertainties between unknown coefficients of foreground templates and the amplitudes of the power spectrum. This effect amounts to correlations and anti-correlations of up to 10 per cent across wide ranges in Fourier space.

  6. Do sampling methods differ in their utility for ecological monitoring? Comparison of line-point intercept, grid-point intercept, and ocular estimate methods

    USDA-ARS?s Scientific Manuscript database

    This study compared the utility of three sampling methods for ecological monitoring based on: interchangeability of data (rank correlations), precision (coefficient of variation), cost (minutes/transect), and potential of each method to generate multiple indicators. Species richness and foliar cover...

  7. Comparison of the accuracy of kriging and IDW interpolations in estimating groundwater arsenic concentrations in Texas.

    PubMed

    Gong, Gordon; Mattevada, Sravan; O'Bryant, Sid E

    2014-04-01

    Exposure to arsenic causes many diseases. Most Americans in rural areas use groundwater for drinking, which may contain arsenic above the currently allowable level, 10µg/L. It is cost-effective to estimate groundwater arsenic levels based on data from wells with known arsenic concentrations. We compared the accuracy of several commonly used interpolation methods in estimating arsenic concentrations in >8000 wells in Texas by the leave-one-out-cross-validation technique. Correlation coefficient between measured and estimated arsenic levels was greater with inverse distance weighted (IDW) than kriging Gaussian, kriging spherical or cokriging interpolations when analyzing data from wells in the entire Texas (p<0.0001). Correlation coefficient was significantly lower with cokriging than any other methods (p<0.006) for wells in Texas, east Texas or the Edwards aquifer. Correlation coefficient was significantly greater for wells in southwestern Texas Panhandle than in east Texas, and was higher for wells in Ogallala aquifer than in Edwards aquifer (p<0.0001) regardless of interpolation methods. In regression analysis, the best models are when well depth and/or elevation were entered into the model as covariates regardless of area/aquifer or interpolation methods, and models with IDW are better than kriging in any area/aquifer. In conclusion, the accuracy in estimating groundwater arsenic level depends on both interpolation methods and wells' geographic distributions and characteristics in Texas. Taking well depth and elevation into regression analysis as covariates significantly increases the accuracy in estimating groundwater arsenic level in Texas with IDW in particular. Published by Elsevier Inc.

  8. Genetic diversity of popcorn genotypes using molecular analysis.

    PubMed

    Resh, F S; Scapim, C A; Mangolin, C A; Machado, M F P S; do Amaral, A T; Ramos, H C C; Vivas, M

    2015-08-19

    In this study, we analyzed dominant molecular markers to estimate the genetic divergence of 26 popcorn genotypes and evaluate whether using various dissimilarity coefficients with these dominant markers influences the results of cluster analysis. Fifteen random amplification of polymorphic DNA primers produced 157 amplified fragments, of which 65 were monomorphic and 92 were polymorphic. To calculate the genetic distances among the 26 genotypes, the complements of the Jaccard, Dice, and Rogers and Tanimoto similarity coefficients were used. A matrix of Dij values (dissimilarity matrix) was constructed, from which the genetic distances among genotypes were represented in a more simplified manner as a dendrogram generated using the unweighted pair-group method with arithmetic average. Clusters determined by molecular analysis generally did not group material from the same parental origin together. The largest genetic distance was between varieties 17 (UNB-2) and 18 (PA-091). In the identification of genotypes with the smallest genetic distance, the 3 coefficients showed no agreement. The 3 dissimilarity coefficients showed no major differences among their grouping patterns because agreement in determining the genotypes with large, medium, and small genetic distances was high. The largest genetic distances were observed for the Rogers and Tanimoto dissimilarity coefficient (0.74), followed by the Jaccard coefficient (0.65) and the Dice coefficient (0.48). The 3 coefficients showed similar estimations for the cophenetic correlation coefficient. Correlations among the matrices generated using the 3 coefficients were positive and had high magnitudes, reflecting strong agreement among the results obtained using the 3 evaluated dissimilarity coefficients.

  9. Methods for presentation and display of multivariate data

    NASA Technical Reports Server (NTRS)

    Myers, R. H.

    1981-01-01

    Methods for the presentation and display of multivariate data are discussed with emphasis placed on the multivariate analysis of variance problems and the Hotelling T(2) solution in the two-sample case. The methods utilize the concepts of stepwise discrimination analysis and the computation of partial correlation coefficients.

  10. Prediction of subacute infarct size in acute middle cerebral artery stroke: comparison of perfusion-weighted imaging and apparent diffusion coefficient maps.

    PubMed

    Drier, Aurélie; Tourdias, Thomas; Attal, Yohan; Sibon, Igor; Mutlu, Gurkan; Lehéricy, Stéphane; Samson, Yves; Chiras, Jacques; Dormont, Didier; Orgogozo, Jean-Marc; Dousset, Vincent; Rosso, Charlotte

    2012-11-01

    To compare perfusion-weighted (PW) imaging and apparent diffusion coefficient (ADC) maps in prediction of infarct size and growth in patients with acute middle cerebral artery infarct. This study was approved by the local institutional review board. Written informed consent was obtained from all 80 patients. Subsequent infarct volume and growth on follow-up magnetic resonance (MR) images obtained within 6 days were compared with the predictions based on PW images by using a time-to-peak threshold greater than 4 seconds and ADC maps obtained less than 12 hours after middle cerebral artery infarct. ADC- and PW imaging-predicted infarct growth areas and infarct volumes were correlated with subsequent infarct growth and follow-up diffusion-weighted (DW) imaging volumes. The impact of MR imaging time delay on the correlation coefficient between the predicted and subsequent infarct volumes and individual predictions of infarct growth by using receiver operating characteristic curves were assessed. The infarct volume measurements were highly reproducible (concordance correlation coefficient [CCC] of 0.965 and 95% confidence interval [CI]: 0.949, 0.976 for acute DW imaging; CCC of 0.995 and 95% CI: 0.993, 0.997 for subacute DW imaging). The subsequent infarct volume correlated (P<.0001) with ADC- (ρ=0.853) and PW imaging- (ρ=0.669) predicted volumes. The correlation was higher for ADC-predicted volume than for PW imaging-predicted volume (P<.005), but not when the analysis was restricted to patients without recanalization (P=.07). The infarct growth correlated (P<.0001) with PW imaging-DW imaging mismatch (ρ=0.470) and ADC-DW imaging mismatch (ρ=0.438), without significant differences between both methods (P=.71). The correlations were similar among time delays with ADC-predicted volumes but decreased with PW imaging-based volumes beyond the therapeutic window. Accuracies of ADC- and PW imaging-based predictions of infarct growth in an individual prediction were similar (area under the receiver operating characteristic curve [AUC] of 0.698 and 95% CI: 0.585, 0.796 vs AUC of 0.749 and 95% CI: 0.640, 0.839; P=.48). The ADC-based method was as accurate as the PW imaging-based method for evaluating infarct growth and size in the subacute phase. © RSNA, 2012

  11. TH-A-18C-03: Noise Correlation in CBCT Projection Data and Its Application for Noise Reduction in Low-Dose CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ZHANG, H; Huang, J; Ma, J

    2014-06-15

    Purpose: To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT. Methods: In this study, we systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam on-board CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 mAs to 1.6 mAs per projection at threemore » fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT. Results: The analyses of the repeated measurements show that noise correlation coefficients are non-zero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second- order neighbors are about 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. Conclusion: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.« less

  12. Assessment of Thematic Mapper Band-to-band Registration by the Block Correlation Method

    NASA Technical Reports Server (NTRS)

    Card, D. H.; Wrigley, R. C.; Mertz, F. C.; Hall, J. R.

    1984-01-01

    The design of the Thematic Mapper (TM) multispectral radiometer makes it susceptible to band-to-band misregistration. To estimate band-to-band misregistration a block correlation method is employed. This method is chosen over other possible techniques (band differencing and flickering) because quantitative results are produced. The method correlates rectangular blocks of pixels from one band against blocks centered on identical pixels from a second band. The block pairs are shifted in pixel increments both vertically and horizontally with respect to each other and the correlation coefficient for each shift position is computed. The displacement corresponding to the maximum correlation is taken as the best estimate of registration error for each block pair. Subpixel shifts are estimated by a bi-quadratic interpolation of the correlation values surrounding the maximum correlation. To obtain statistical summaries for each band combination post processing of the block correlation results performed. The method results in estimates of registration error that are consistent with expectations.

  13. A method for predicting the noise levels of coannular jets with inverted velocity profiles

    NASA Technical Reports Server (NTRS)

    Russell, J. W.

    1979-01-01

    A coannular jet was equated with a single stream equivalent jet with the same mass flow, energy, and thrust. The acoustic characteristics of the coannular jet were then related to the acoustic characteristics of the single jet. Forward flight effects were included by incorporating a forward exponent, a Doppler amplification factor, and a Strouhal frequency shift. Model test data, including 48 static cases and 22 wind tunnel cases, were used to evaluate the prediction method. For the static cases and the low forward velocity wind tunnel cases, the spectral mean square pressure correlation coefficients were generally greater than 90 percent, and the spectral sound pressure level standard deviation were generally less than 3 decibels. The correlation coefficient and the standard deviation were not affected by changes in equivalent jet velocity. Limitations of the prediction method are also presented.

  14. Building Area Extraction from Polarimetric SAR Data via Stationarity Detection and Circular-Pol Correlation Coefficient

    NASA Astrophysics Data System (ADS)

    Xiang, Deliang; Su, Yi; Ban, Yifeng

    2015-04-01

    Since the buildings have complex geometries and may be misclassified as forests or mountains with volume scattering due to the significant cross-pol backscatter and lack reflection symmetry, especially the slant-oriented buildings, building area extraction is a challenging problem. In this paper, the time-frequency decomposition technique is adopted to acquire subaperture images, which correspond to the same scene responses under different azimuthal look angles. Stationarity detection approach with polarimetric G0 distribution is proposed to extract ortho-orientedbuildings and the circular polarization correlation coefficient is optimal in characterizing slant-oriented buildings. We test the aforementioned method using ESAR image with L-band. The results demonstrate that the proposed method can effectively extract both ortho-oriented and slant-oriented buildings and the overall detection accuracy as well as kappa value is 10%-20% higher than the compared methods.

  15. Detrended cross-correlation coefficient: Application to predict apoptosis protein subcellular localization.

    PubMed

    Liang, Yunyun; Liu, Sanyang; Zhang, Shengli

    2016-12-01

    Apoptosis, or programed cell death, plays a central role in the development and homeostasis of an organism. Obtaining information on subcellular location of apoptosis proteins is very helpful for understanding the apoptosis mechanism. The prediction of subcellular localization of an apoptosis protein is still a challenging task, and existing methods mainly based on protein primary sequences. In this paper, we introduce a new position-specific scoring matrix (PSSM)-based method by using detrended cross-correlation (DCCA) coefficient of non-overlapping windows. Then a 190-dimensional (190D) feature vector is constructed on two widely used datasets: CL317 and ZD98, and support vector machine is adopted as classifier. To evaluate the proposed method, objective and rigorous jackknife cross-validation tests are performed on the two datasets. The results show that our approach offers a novel and reliable PSSM-based tool for prediction of apoptosis protein subcellular localization. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. A Study of Correlation of Various Growth Indicators with Chronological Age.

    PubMed

    Singh, Sarabjeet; Sandhu, Navreet; Puri, Taruna; Gulati, Ritika; Kashyap, Rita

    2015-01-01

    The aim of this study was to assess the relationship of chronological age with cervical vertebrae skeletal maturation, frontal sinus width and antegonial notch depth and a correlation, if any, among the three variables. The samples were derived from lateral cephalometric radiographs of 80 subjects (40 males, 40 females; age range: 10 to 19 years). Cervical vertebral development was evaluated by the method of Hassel and Farman, frontal sinus width was measured by the method described by Ertürk and antegonial notch depth as described by Singer et al. The Pearson's correlation coefficients were estimated to assess the relationship of chronological age with cervical vertebrae skeletal maturation, frontal sinus width and antegonial notch depth. The Pearson's correlation coefficient were 0.855 (p < 0.001) between chronological age and cervical vertebrae skeletal maturation, and 0.333 (p < 0.001) between chronological age and frontal sinus width. A highly significant positive correlation was found between chronological age and cervical vertebrae skeletal maturation, and between chronological age and frontal sinus width. Nonsignificant correlation was found between chronological age and antegonial notch depth. How to cite this article: Singh S, Sandhu N, Puri T, Gulati R, Kashyap R. A Study of Correlation of Various Growth Indicators with Chronological Age. Int J Clin Pediatr Dent 2015;8(3): 190-195.

  17. Predicting cyclohexane/water distribution coefficients for the SAMPL5 challenge using MOSCED and the SMD solvation model.

    PubMed

    Diaz-Rodriguez, Sebastian; Bozada, Samantha M; Phifer, Jeremy R; Paluch, Andrew S

    2016-11-01

    We present blind predictions using the solubility parameter based method MOSCED submitted for the SAMPL5 challenge on calculating cyclohexane/water distribution coefficients at 298 K. Reference data to parameterize MOSCED was generated with knowledge only of chemical structure by performing solvation free energy calculations using electronic structure calculations in the SMD continuum solvent. To maintain simplicity and use only a single method, we approximate the distribution coefficient with the partition coefficient of the neutral species. Over the final SAMPL5 set of 53 compounds, we achieved an average unsigned error of [Formula: see text] log units (ranking 15 out of 62 entries), the correlation coefficient (R) was [Formula: see text] (ranking 35), and [Formula: see text] of the predictions had the correct sign (ranking 30). While used here to predict cyclohexane/water distribution coefficients at 298 K, MOSCED is broadly applicable, allowing one to predict temperature dependent infinite dilution activity coefficients in any solvent for which parameters exist, and provides a means by which an excess Gibbs free energy model may be parameterized to predict composition dependent phase-equilibrium.

  18. Extracting rate coefficients from single-molecule photon trajectories and FRET efficiency histograms for a fast-folding protein.

    PubMed

    Chung, Hoi Sung; Gopich, Irina V; McHale, Kevin; Cellmer, Troy; Louis, John M; Eaton, William A

    2011-04-28

    Recently developed statistical methods by Gopich and Szabo were used to extract folding and unfolding rate coefficients from single-molecule Förster resonance energy transfer (FRET) data for proteins with kinetics too fast to measure waiting time distributions. Two types of experiments and two different analyses were performed. In one experiment bursts of photons were collected from donor and acceptor fluorophores attached to a 73-residue protein, α(3)D, freely diffusing through the illuminated volume of a confocal microscope system. In the second, the protein was immobilized by linkage to a surface, and photons were collected until one of the fluorophores bleached. Folding and unfolding rate coefficients and mean FRET efficiencies for the folded and unfolded subpopulations were obtained from a photon by photon analysis of the trajectories using a maximum likelihood method. The ability of the method to describe the data in terms of a two-state model was checked by recoloring the photon trajectories with the extracted parameters and comparing the calculated FRET efficiency histograms with the measured histograms. The sum of the rate coefficients for the two-state model agreed to within 30% with the relaxation rate obtained from the decay of the donor-acceptor cross-correlation function, confirming the high accuracy of the method. Interestingly, apparently reliable rate coefficients could be extracted using the maximum likelihood method, even at low (<10%) population of the minor component where the cross-correlation function was too noisy to obtain any useful information. The rate coefficients and mean FRET efficiencies were also obtained in an approximate procedure by simply fitting the FRET efficiency histograms, calculated by binning the donor and acceptor photons, with a sum of three-Gaussian functions. The kinetics are exposed in these histograms by the growth of a FRET efficiency peak at values intermediate between the folded and unfolded peaks as the bin size increases, a phenomenon with similarities to NMR exchange broadening. When comparable populations of folded and unfolded molecules are present, this method yields rate coefficients in very good agreement with those obtained with the maximum likelihood method. As a first step toward characterizing transition paths, the Viterbi algorithm was used to locate the most probable transition points in the photon trajectories.

  19. Accuracy of MRI skeletal age estimation for subjects 12-19. Potential use for subjects of unknown age.

    PubMed

    Serinelli, Serenella; Panebianco, Valeria; Martino, Milvia; Battisti, Sofia; Rodacki, Karina; Marinelli, Enrico; Zaccagna, Fulvio; Semelka, Richard C; Tomei, Ernesto

    2015-05-01

    In forensic practice, there is a growing need for accurate methods of age estimation, especially in the cases of young individuals of unknown age. Age can be estimated through somatic features that are universally considered associated with chronological age. Unfortunately, these features do not always coincide with the real chronological age: for these reasons that age determination is often very difficult. Our aim is to evaluate accuracy of skeletal age estimation using Tomei's MRI method in subjects between 12 and 19 years old for forensic purposes. Two investigators analyzed MRI images of the left hand and wrist of 77 male and 74 female caucasian subjects, without chronic diseases or developmental disorders, whose age ranged from 12 to 19 years. Skeletal maturation was determined by two operators, who analyzed all MRI images separately, in blinded fashion to the chronological age. Inter-rater agreement was measured with Pearson (R (2)) coefficient. One of the examiners repeated the evaluation after 6 months, and intraobserver variation was analyzed. Bland-Altman plots were used to determine mean differences between skeletal and chronological age. Inter-rater agreement Pearson coefficient showed a good linear correlation, respectively, 0.98 and 0.97 in males and females. Bland-Altman analysis demonstrated that the differences between chronological and skeletal age are not significant. Spearman's correlation coefficient showed good correlation between skeletal and chronological age both in females (R (2) = 0.96) and in males (R (2) = 0.94). Our results show that MRI skeletal age is a reproducible method and has good correlation with chronological age.

  20. A novel method for real-time edge-enhancement and its application to pattern recognition

    NASA Astrophysics Data System (ADS)

    Ge, Huayong; Bai, Enjian; Fan, Hong

    2010-11-01

    The coupling gain coefficient g is redefined and deduced based on coupling theory, the variant of coupling gain coefficient g for different ΓL and r is analyzed. A new optical system is proposed for image edge-enhancement. It recycles the back signal to amplify the edge signal, which has the advantages of high throughput efficiency and brightness. The optical system is designed and built, and the edge-enhanced image of hand bone is captured electronically by CCD camera. The principle of optical correlation is demonstrated, 3-D correlation distribution of letter H with and without edge-enhancement is simulated, the discrimination capability Iac and the full-width at half maximum intensity (FWHM) are compared for two kinds of correlators. The analysis shows that edge-enhancement preprocessing can improve the performance of correlator effectively.

  1. Effective screening length and quasiuniversality for the restricted primitive model of an electrolyte solution.

    PubMed

    Janecek, Jirí; Netz, Roland R

    2009-02-21

    Monte Carlo simulations for the restricted primitive model of an electrolyte solution above the critical temperature are performed at a wide range of concentrations and temperatures. Thermodynamic properties such as internal energy, osmotic coefficient, activity coefficient, as well as spatial correlation functions are determined. These observables are used to investigate whether quasiuniversality in terms of an effective screening length exists, similar to the role played by the effective electron mass in solid-state physics. To that end, an effective screening length is extracted from the asymptotic behavior of the Fourier-transformed charge-correlation function and plugged into the Debye-Huckel limiting expressions for various thermodynamic properties. Comparison with numerical results is favorable, suggesting that correlation and other effects not captured on the Debye-Huckel limiting level can be successfully incorporated by a single effective parameter while keeping the functional form of Debye-Huckel expressions. We also compare different methods to determine mean ionic activity coefficient in molecular simulations and check the internal consistency of the numerical data.

  2. Evaluating the Applicability of Phi Coefficient in Indicating Habitat Preferences of Forest Soil Fauna Based on a Single Field Study in Subtropical China.

    PubMed

    Cui, Yang; Wang, Silong; Yan, Shaokui

    2016-01-01

    Phi coefficient directly depends on the frequencies of occurrence of organisms and has been widely used in vegetation ecology to analyse the associations of organisms with site groups, providing a characterization of ecological preference, but its application in soil ecology remains rare. Based on a single field experiment, this study assessed the applicability of phi coefficient in indicating the habitat preferences of soil fauna, through comparing phi coefficient-induced results with those of ordination methods in charactering soil fauna-habitat(factors) relationships. Eight different habitats of soil fauna were implemented by reciprocal transfer of defaunated soil cores between two types of subtropical forests. Canonical correlation analysis (CCorA) showed that ecological patterns of fauna-habitat relationships and inter-fauna taxa relationships expressed, respectively, by phi coefficients and predicted abundances calculated from partial redundancy analysis (RDA), were extremely similar, and a highly significant relationship between the two datasets was observed (Pillai's trace statistic = 1.998, P = 0.007). In addition, highly positive correlations between phi coefficients and predicted abundances for Acari, Collembola, Nematode and Hemiptera were observed using linear regression analysis. Quantitative relationships between habitat preferences and soil chemical variables were also obtained by linear regression, which were analogous to the results displayed in a partial RDA biplot. Our results suggest that phi coefficient could be applicable on a local scale in evaluating habitat preferences of soil fauna at coarse taxonomic levels, and that the phi coefficient-induced information, such as ecological preferences and the associated quantitative relationships with habitat factors, will be largely complementary to the results of ordination methods. The application of phi coefficient in soil ecology may extend our knowledge about habitat preferences and distribution-abundance relationships, which will benefit the understanding of biodistributions and variations in community compositions in the soil. Similar studies in other places and scales apart from our local site will be need for further evaluation of phi coefficient.

  3. Evaluating the Applicability of Phi Coefficient in Indicating Habitat Preferences of Forest Soil Fauna Based on a Single Field Study in Subtropical China

    PubMed Central

    Cui, Yang; Wang, Silong; Yan, Shaokui

    2016-01-01

    Phi coefficient directly depends on the frequencies of occurrence of organisms and has been widely used in vegetation ecology to analyse the associations of organisms with site groups, providing a characterization of ecological preference, but its application in soil ecology remains rare. Based on a single field experiment, this study assessed the applicability of phi coefficient in indicating the habitat preferences of soil fauna, through comparing phi coefficient-induced results with those of ordination methods in charactering soil fauna-habitat(factors) relationships. Eight different habitats of soil fauna were implemented by reciprocal transfer of defaunated soil cores between two types of subtropical forests. Canonical correlation analysis (CCorA) showed that ecological patterns of fauna-habitat relationships and inter-fauna taxa relationships expressed, respectively, by phi coefficients and predicted abundances calculated from partial redundancy analysis (RDA), were extremely similar, and a highly significant relationship between the two datasets was observed (Pillai's trace statistic = 1.998, P = 0.007). In addition, highly positive correlations between phi coefficients and predicted abundances for Acari, Collembola, Nematode and Hemiptera were observed using linear regression analysis. Quantitative relationships between habitat preferences and soil chemical variables were also obtained by linear regression, which were analogous to the results displayed in a partial RDA biplot. Our results suggest that phi coefficient could be applicable on a local scale in evaluating habitat preferences of soil fauna at coarse taxonomic levels, and that the phi coefficient-induced information, such as ecological preferences and the associated quantitative relationships with habitat factors, will be largely complementary to the results of ordination methods. The application of phi coefficient in soil ecology may extend our knowledge about habitat preferences and distribution-abundance relationships, which will benefit the understanding of biodistributions and variations in community compositions in the soil. Similar studies in other places and scales apart from our local site will be need for further evaluation of phi coefficient. PMID:26930593

  4. [Determination of steviol in Stevia Rebaudiana leaves by near infrared spectroscopy].

    PubMed

    Tang, Qi-Kun; Wang, Yul; Wu, Yue-Jin; Min, Di; Chen, Da-Wei; Hu, Tong-Hua

    2014-10-01

    The objective of the present study is to develop a method for rapid determination of the content of stevioside (ST) and rebaudioside A (RA) in Stevia Rebaudiana leaves. One hundred and five samples of stevia from different areas containing ST of 0.27%-1.40% and RA of 0.61%-3.98% were used. The 105 groups' NIRS diagram was processed by different methods including subtracting a straight line (SLS), multiplicative scatter correction (MSC), first derivative (FD), second derivative (SD) and so on, and then all data were analyzed by partial least square (PLS). The study showed that SLS can be used to extracted spectra information thoroughly to analyze the contents of ST, the correlation coefficients of calibration (Re), the root-mean-square errors of calibration (RMSEC) and prediction (RMSEP), and the residual predictive deviation (RPD) were 0.986, 0.341, 1.00 and 2.8, respectively. The correlation coefficients of RA was 0.967, RMSEC was 1.50, RMSEP was 1.98 and RPD was 4.17. The results indicated that near infrared spectroscopy (NIRS) technique offers effective quantitative capability for ST and RA in Stevia Rebaudiana leaves. Then the model of stevia dried leaves was used to compare with the stevia powder near infrared model whose correlation coefficients of ST was 0.986, RMSEC was 0.32, RMSEP was 0.601 and RPD was 2.86 and the correlation coefficients of RA was 0.968, RMSEC was 1.50, RMSEP was 1.48 and RPD was 4.2. The result showed that there was no significant difference between the model of dried leaves and that of the powders. However, the dried leaves NIR model reduces the unnecessary the steps of drying and grinding in the actual detection process, saving the time and reducing the workload.

  5. Correlations between the Various Methods of Estimating Prostate Volume: Transabdominal, Transrectal, and Three-Dimensional US

    PubMed Central

    Kim, Seung Hyup

    2008-01-01

    Objective To evaluate the correlations between prostate volumes estimated by transabdominal, transrectal, and three-dimensional US and the factors affecting the differences. Materials and Methods The prostate volumes of 94 consecutive patients were measured by both transabdominal and transrectal US. Next, the prostate volumes of 58 other patients was measured by both transrectal and three-dimensional US. We evaluated the degree of correlation and mean difference in each comparison. We also analyzed possible factors affecting the differences, such as the experiences of examiners in transrectal US, bladder volume, and prostate volume. Results In the comparison of transabdominal and transrectal US methods, the mean difference was 8.4 ± 10.5 mL and correlation coefficient (r) was 0.775 (p < 0.01). The experienced examiner for the transrectal US method had the highest correlation (r = 0.967) and the significantly smallest difference (5.4 ± 3.9 mL) compared to the other examiners (the beginner and the trained; p < 0.05). Prostate volume measured by transrectal US showed a weak correlation with the difference (r = 0.360, p < 0.05). Bladder volume did not show significant correlation with the difference (r = -0.043, p > 0.05). The comparison between the transrectal and three-dimensional US methods revealed a mean difference of 3.7 ± 3.4 mL and the correlation coefficient was 0.924 for the experienced examiner. Furthermore, no significant difference existed between examiners (p > 0.05). Prostate volume measured by transrectal US showed a positive correlation with the difference for the beginner only (r = 0.405, p < 0.05). Conclusion In the prostate volume estimation by US, experience in transrectal US is important in the correlation with transabdominal US, but not with three-dimensional US. Also, less experienced examiners' assessment of the prostate volume can be affected by prostate volume itself. PMID:18385560

  6. Correlation between hippocampal volumes and medial temporal lobe atrophy in patients with Alzheimer's disease.

    PubMed

    Dhikav, Vikas; Duraiswamy, Sharmila; Anand, Kuljeet Singh

    2017-01-01

    Hippocampus undergoes atrophy in patients with Alzheimer's disease (AD). Calculation of hippocampal volumes can be done by a variety of methods using T1-weighted images of magnetic resonance imaging (MRI) of the brain. Medial temporal lobes atrophy (MTL) can be rated visually using T1-weighted MRI brain images. The present study was done to see if any correlation existed between hippocampal volumes and visual rating scores of the MTL using Scheltens Visual Rating Method. We screened 84 subjects presented to the Department of Neurology of a Tertiary Care Hospital and enrolled forty subjects meeting the National Institute of Neurological and Communicative Disorders and Stroke, AD related Disease Association criteria. Selected patients underwent MRI brain and T1-weighted images in a plane perpendicular to long axis of hippocampus were obtained. Hippocampal volumes were calculated manually using a standard protocol. The calculated hippocampal volumes were correlated with Scheltens Visual Rating Method for Rating MTL. A total of 32 cognitively normal age-matched subjects were selected to see the same correlation in the healthy subjects as well. Sensitivity and specificity of both methods was calculated and compared. There was an insignificant correlation between the hippocampal volumes and MTL rating scores in cognitively normal elderly ( n = 32; Pearson Correlation coefficient = 0.16, P > 0.05). In the AD Group, there was a moderately strong correlation between measured hippocampal volumes and MTL Rating (Pearson's correlation coefficient = -0.54; P < 0.05. There was a moderately strong correlation between hippocampal volume and Mini-Mental Status Examination in the AD group. Manual delineation was superior compared to the visual method ( P < 0.05). Good correlation was present between manual hippocampal volume measurements and MTL scores. Sensitivity and specificity of manual measurement of hippocampus was higher compared to visual rating scores for MTL in patients with AD.

  7. The Role of Body Adiposity Index in Determining Body Fat Percentage in Colombian Adults with Overweight or Obesity.

    PubMed

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Tordecilla-Sanders, Alejandra; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline; González-Jiménez, Emilio

    2017-09-21

    The aim of this study is to investigate the accuracy of body adiposity index (BAI) as a convenient tool for assessing body fat percentage (BF%) in a sample of adults with overweight/obesity using bioelectrical impedance analysis (BIA). The study population was composed of 96 volunteers (60% female, mean age 40.6 ± 7.5 years old). Anthropometric characteristics (body mass index, height, waist-to-height ratio, hip and waist circumference), socioeconomic status, and diet were assessed, and BF% was measured by BIA-BF% and by BAI-BF%. Pearson's correlation coefficient was used to evaluate the correlation between BAI-BF% and BF% assessed by BIA-BF%, while controlling for potential confounders. The concordance between the BF% measured by both methods was obtained with a paired sample t -test, Lin's concordance correlation coefficient, and Bland-Altman plot analysis. Overall, the correlation between BF% obtained by BIA-BF% and estimated by BAI-BF% was r = 0.885, p < 0.001, after adjusting for potential confounders (age, socioeconomic status, and diet). Lin's concordance correlation coefficient was moderate in both sexes. In the men, the paired t-test showed a significant mean difference in BF% between the methods (-5.6 (95%CI -6.4 to -4.8); p < 0.001). In the women, these differences were (-3.6 (95%CI -4.7 to -2.5); p < 0.001). Overall, the bias of the BAI-BF% was -4.8 ± 3.2 BF%; p < 0.001), indicating that the BAI-BF% method significantly underestimated the BF% in comparison with the reference method. In adults with overweight/obesity, the BAI presents low agreement with BF% measured by BIA-BF%; therefore, we conclude that BIA-BF% is not accurate in either sex when body fat percentage levels are low or high. Further studies are necessary to confirm our findings in different ethnic groups.

  8. The Role of Body Adiposity Index in Determining Body Fat Percentage in Colombian Adults with Overweight or Obesity

    PubMed Central

    González-Ruíz, Katherine; Schmidt-RioValle, Jacqueline

    2017-01-01

    The aim of this study is to investigate the accuracy of body adiposity index (BAI) as a convenient tool for assessing body fat percentage (BF%) in a sample of adults with overweight/obesity using bioelectrical impedance analysis (BIA). The study population was composed of 96 volunteers (60% female, mean age 40.6 ± 7.5 years old). Anthropometric characteristics (body mass index, height, waist-to-height ratio, hip and waist circumference), socioeconomic status, and diet were assessed, and BF% was measured by BIA-BF% and by BAI-BF%. Pearson’s correlation coefficient was used to evaluate the correlation between BAI-BF% and BF% assessed by BIA-BF%, while controlling for potential confounders. The concordance between the BF% measured by both methods was obtained with a paired sample t-test, Lin’s concordance correlation coefficient, and Bland-Altman plot analysis. Overall, the correlation between BF% obtained by BIA-BF% and estimated by BAI-BF% was r = 0.885, p < 0.001, after adjusting for potential confounders (age, socioeconomic status, and diet). Lin’s concordance correlation coefficient was moderate in both sexes. In the men, the paired t-test showed a significant mean difference in BF% between the methods (−5.6 (95% CI −6.4 to −4.8); p < 0.001). In the women, these differences were (−3.6 (95% CI −4.7 to −2.5); p < 0.001). Overall, the bias of the BAI-BF% was −4.8 ± 3.2 BF%; p < 0.001), indicating that the BAI-BF% method significantly underestimated the BF% in comparison with the reference method. In adults with overweight/obesity, the BAI presents low agreement with BF% measured by BIA-BF%; therefore, we conclude that BIA-BF% is not accurate in either sex when body fat percentage levels are low or high. Further studies are necessary to confirm our findings in different ethnic groups. PMID:28934175

  9. Maximum Likelihood Estimation in Meta-Analytic Structural Equation Modeling

    ERIC Educational Resources Information Center

    Oort, Frans J.; Jak, Suzanne

    2016-01-01

    Meta-analytic structural equation modeling (MASEM) involves fitting models to a common population correlation matrix that is estimated on the basis of correlation coefficients that are reported by a number of independent studies. MASEM typically consist of two stages. The method that has been found to perform best in terms of statistical…

  10. Hierarchical multivariate covariance analysis of metabolic connectivity

    PubMed Central

    Carbonell, Felix; Charil, Arnaud; Zijdenbos, Alex P; Evans, Alan C; Bedell, Barry J

    2014-01-01

    Conventional brain connectivity analysis is typically based on the assessment of interregional correlations. Given that correlation coefficients are derived from both covariance and variance, group differences in covariance may be obscured by differences in the variance terms. To facilitate a comprehensive assessment of connectivity, we propose a unified statistical framework that interrogates the individual terms of the correlation coefficient. We have evaluated the utility of this method for metabolic connectivity analysis using [18F]2-fluoro-2-deoxyglucose (FDG) positron emission tomography (PET) data from the Alzheimer's Disease Neuroimaging Initiative (ADNI) study. As an illustrative example of the utility of this approach, we examined metabolic connectivity in angular gyrus and precuneus seed regions of mild cognitive impairment (MCI) subjects with low and high β-amyloid burdens. This new multivariate method allowed us to identify alterations in the metabolic connectome, which would not have been detected using classic seed-based correlation analysis. Ultimately, this novel approach should be extensible to brain network analysis and broadly applicable to other imaging modalities, such as functional magnetic resonance imaging (MRI). PMID:25294129

  11. Instrument validation process: a case study using the Paediatric Pain Knowledge and Attitudes Questionnaire.

    PubMed

    Peirce, Deborah; Brown, Janie; Corkish, Victoria; Lane, Marguerite; Wilson, Sally

    2016-06-01

    To compare two methods of calculating interrater agreement while determining content validity of the Paediatric Pain Knowledge and Attitudes Questionnaire for use with Australian nurses. Paediatric pain assessment and management documentation was found to be suboptimal revealing a need to assess paediatric nurses' knowledge and attitude to pain. The Paediatric Pain Knowledge and Attitudes Questionnaire was selected as it had been reported as valid and reliable in the United Kingdom with student nurses. The questionnaire required content validity determination prior to use in the Australian context. A two phase process of expert review. Ten paediatric nurses completed a relevancy rating of all 68 questionnaire items. In phase two, five pain experts reviewed the items of the questionnaire that scored an unacceptable item level content validity. Item and scale level content validity indices and intraclass correlation coefficients were calculated. In phase one, 31 items received an item level content validity index <0·78 and the scale level content validity index average was 0·80 which were below levels required for acceptable validity. The intraclass correlation coefficient was 0·47. In phase two, 10 items were amended and four items deleted. The revised questionnaire provided a scale level content validity index average >0·90 and an intraclass correlation coefficient of 0·94 demonstrating excellent agreement between raters therefore acceptable content validity. Equivalent outcomes were achieved using the content validity index and the intraclass correlation coefficient. To assess content validity the content validity index has the advantage of providing an item level score and is a simple calculation. The intraclass correlation coefficient requires statistical knowledge, or support, and has the advantage of accounting for the possibility of chance agreement. © 2016 John Wiley & Sons Ltd.

  12. Reliability and Validity of a Chinese-Translated Version of a Pregnancy Physical Activity Questionnaire.

    PubMed

    Xiang, Mi; Konishi, Massayuki; Hu, Huanhuan; Takahashi, Masaki; Fan, Wenbi; Nishimaki, Mio; Ando, Karina; Kim, Hyeon-Ki; Tabata, Hiroki; Arao, Takashi; Sakamoto, Shizuo

    2016-09-01

    Objectives The objectives of the present study were to translate the English version of the Pregnancy Physical Activity Questionnaire into Chinese (PPAQ-C) and to determine its reliability and validity for use by pregnant Chinese women. Methods The study included 224 pregnant women during their first, second, or third trimesters of pregnancy who completed the PPAQ-C on their first visit and wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd) for 7 days. One week after the first visit, we collected the data from the uniaxial accelerometer records, and the women were asked to complete the PPAQ-C again. Results We used intraclass correlation coefficients to determine the reliability of the PPAQ-C. The intraclass correlation coefficients were 0.77 for total activity (light and above), 0.76 for sedentary activity, 0.75 for light activity, 0.59 for moderate activity, and 0.28 for vigorous activity. The intraclass correlation coefficients were 0.74 for "household and caregiving", 0.75 for "occupational" activities, and 0.34 for "sports/exercise". Validity between the PPAQ-C and accelerometer data was determined by Spearman correlation coefficients. Although there were no significant correlations for moderate activity (r = 0.19, P > 0.05) or vigorous activity (r = 0.15, P > 0.05), there were significant correlations for total activity [light and above; r = 0.35, P < 0.01)] and for light activity (r = 0.33, P < 0.01). Conclusions for Practice The PPAQ-C is reliable and moderately accurate for measuring physical activity in pregnant Chinese women.

  13. Simple, simultaneous gravimetric determination of calcite and dolomite in calcareous soils

    USDA-ARS?s Scientific Manuscript database

    Literature pertaining to determination of calcite and dolomite is not modern and describes slow methods that require expensive specialized apparatus. The objective of this paper was to describe a new method that requires no specialized equipment. Linear regressions and correlation coefficients for...

  14. Threshold network of a financial market using the P-value of correlation coefficients

    NASA Astrophysics Data System (ADS)

    Ha, Gyeong-Gyun; Lee, Jae Woo; Nobi, Ashadun

    2015-06-01

    Threshold methods in financial networks are important tools for obtaining important information about the financial state of a market. Previously, absolute thresholds of correlation coefficients have been used; however, they have no relation to the length of time. We assign a threshold value depending on the size of the time window by using the P-value concept of statistics. We construct a threshold network (TN) at the same threshold value for two different time window sizes in the Korean Composite Stock Price Index (KOSPI). We measure network properties, such as the edge density, clustering coefficient, assortativity coefficient, and modularity. We determine that a significant difference exists between the network properties of the two time windows at the same threshold, especially during crises. This implies that the market information depends on the length of the time window when constructing the TN. We apply the same technique to Standard and Poor's 500 (S&P500) and observe similar results.

  15. The reliability of Cavalier's principle of stereological method in determining volumes of enchondromas using the computerized tomography tools.

    PubMed

    Acar, Nihat; Karakasli, Ahmet; Karaarslan, Ahmet; Mas, Nermin Ng; Hapa, Onur

    2017-01-01

    Volumetric measurements of benign tumors enable surgeons to trace volume changes during follow-up periods. For a volumetric measurement technique to be applicable, it should be easy, rapid, and inexpensive and should carry a high interobserver reliability. We aimed to assess the interobserver reliability of a volumetric measurement technique using the Cavalier's principle of stereological methods. The computerized tomography (CT) of 15 patients with a histopathologically confirmed diagnosis of enchondroma with variant tumor sizes and localizations was retrospectively reviewed for interobserver reliability evaluation of the volumetric stereological measurement with the Cavalier's principle, V = t × [((SU) × d) /SL]2 × Σ P. The volumes of the 15 tumors collected by the observers are demonstrated in Table 1. There was no statistical significance between the first and second observers ( p = 0.000 and intraclass correlation coefficient = 0.970) and between the first and third observers ( p = 0.000 and intraclass correlation coefficient = 0.981). No statistical significance was detected between the second and third observers ( p = 0.000 and intraclass correlation coefficient = 0.976). The Cavalier's principle with the stereological technique using the CT scans is an easy, rapid, and inexpensive technique in volumetric evaluation of enchondromas with a trustable interobserver reliability.

  16. Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

    PubMed Central

    Kim, Won Kuel; Seo, Kyung Mook; Kang, Si Hyun

    2014-01-01

    Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35° angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength. PMID:24639931

  17. Sherwood correlation for dissolution of pooled NAPL in porous media

    NASA Astrophysics Data System (ADS)

    Aydin Sarikurt, Derya; Gokdemir, Cagri; Copty, Nadim K.

    2017-11-01

    The rate of interphase mass transfer from non-aqueous phase liquids (NAPLs) entrapped in the subsurface into the surrounding mobile aqueous phase is commonly expressed in terms of Sherwood (Sh) correlations that are expressed as a function of flow and porous media properties. Because of the lack of precise methods for the estimation of the interfacial area separating the NAPL and aqueous phases, most studies have opted to use modified Sherwood expressions that lump the interfacial area into the interphase mass transfer coefficient. To date, there are only two studies in the literature that have developed non-lumped Sherwood correlations; however, these correlations have undergone limited validation. In this paper controlled dissolution experiments from pooled NAPL were conducted. The immobile NAPL mass is placed at the bottom of a flow cell filled with porous media with water flowing horizontally on top. Effluent aqueous phase concentrations were measured for a wide range of aqueous phase velocities and for two different porous media. To interpret the experimental results, a two-dimensional pore network model of the NAPL dissolution kinetics and aqueous phase transport was developed. The observed effluent concentrations were then used to compute best-fit mass transfer coefficients. Comparison of the effluent concentrations computed with the two-dimensional pore network model to those estimated with one-dimensional analytical solutions indicates that the analytical model which ignores the transport in the lateral direction can lead to under-estimation of the mass transfer coefficient. Based on system parameters and the estimated mass transfer coefficients, non-lumped Sherwood correlations were developed and compared to previously published data. The developed correlations, which are a significant improvement over currently available correlations that are associated with large uncertainties, can be incorporated into future modeling studies requiring non-lumped Sh expressions.

  18. SPATIAL DISTRIBUTIONS OF ABSORPTION, LOCAL SUPPRESSION, AND EMISSIVITY REDUCTION OF SOLAR ACOUSTIC WAVES IN MAGNETIC REGIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chou, D.-Y.; Yang, M.-H.; Zhao Hui

    Observed acoustic power in magnetic regions is lower than the quiet Sun because of absorption, emissivity reduction, and local suppression of solar acoustic waves in magnetic regions. In the previous studies, we have developed a method to measure the coefficients of absorption, emissivity reduction, and local suppression of sunspots. In this study, we go one step further to measure the spatial distributions of three coefficients in two active regions, NOAA 9055 and 9057. The maps of absorption, emissivity reduction, and local suppression coefficients correlate with the magnetic map, including plage regions, except the emissivity reduction coefficient of NOAA 9055 wheremore » the emissivity reduction coefficient is too weak and lost among the noise.« less

  19. Correlation of the apparent diffusion coefficient and the standardized uptake value in neoplastic lesions: a meta-analysis.

    PubMed

    Shen, Guohua; Ma, Huan; Liu, Bin; Ren, Pengwei; Kuang, Anren

    2017-12-01

    Diffusion-weighted imaging and fluorine-18-fluorodeoxyglucose PET are increasingly being recognized as feasible oncological techniques. The apparent diffusion coefficient (ADC) measured by diffusion-weighted imaging and the standardized uptake value (SUV) from fluorine-18-fluorodeoxyglucose PET have similar clinical applications. The aim of this study was to assess the correlation between these two parameters in various cancers. Several major databases were searched for eligible studies. The correlation coefficient (ρ) values were pooled in a random-effects model. Begg's test was used to analyze the existence of publication bias and the sources of heterogeneity were explored in subgroup analyses on the basis of study design, diagnostic method, scanning modality, and tumor type. Thirty-five articles were accepted. The pooled ρ value of all of the accepted studies was -0.30 (95% confidence interval: -0.33 to -0.27), and notable heterogeneity was present (I=69.4%, P<0.001), which indicated a relatively weak negative correlation. The pooled ρ values were -0.26, -0.33, -0.32, and -0.33 for the SUVmax/ADCmean, SUVmax/ADCmin, SUVmean/ADCmean, and SUVmean/ADCmin relationships, respectively. The study design and diagnostic method were potential sources of heterogeneity. Lung cancer showed a stronger correlation (ρ=-0.42) than head and neck cancer (ρ=-0.27), cervical cancer (ρ=-0.21), and breast cancer (ρ=-0.23). A Begg's test indicated no significant publication bias among the accepted studies (P>0.05). The two functional parameters of ADC and SUV showed a very weak inverse correlation, which may contribute toward a sophisticated characterization of tumor biology. However, the findings require further validation with trials with large samples and different tumor types.

  20. CORRELATED AND ZONAL ERRORS OF GLOBAL ASTROMETRIC MISSIONS: A SPHERICAL HARMONIC SOLUTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, V. V.; Dorland, B. N.; Gaume, R. A.

    We propose a computer-efficient and accurate method of estimating spatially correlated errors in astrometric positions, parallaxes, and proper motions obtained by space- and ground-based astrometry missions. In our method, the simulated observational equations are set up and solved for the coefficients of scalar and vector spherical harmonics representing the output errors rather than for individual objects in the output catalog. Both accidental and systematic correlated errors of astrometric parameters can be accurately estimated. The method is demonstrated on the example of the JMAPS mission, but can be used for other projects in space astrometry, such as SIM or JASMINE.

  1. Correlated and Zonal Errors of Global Astrometric Missions: A Spherical Harmonic Solution

    NASA Astrophysics Data System (ADS)

    Makarov, V. V.; Dorland, B. N.; Gaume, R. A.; Hennessy, G. S.; Berghea, C. T.; Dudik, R. P.; Schmitt, H. R.

    2012-07-01

    We propose a computer-efficient and accurate method of estimating spatially correlated errors in astrometric positions, parallaxes, and proper motions obtained by space- and ground-based astrometry missions. In our method, the simulated observational equations are set up and solved for the coefficients of scalar and vector spherical harmonics representing the output errors rather than for individual objects in the output catalog. Both accidental and systematic correlated errors of astrometric parameters can be accurately estimated. The method is demonstrated on the example of the JMAPS mission, but can be used for other projects in space astrometry, such as SIM or JASMINE.

  2. Breast density estimation from high spectral and spatial resolution MRI

    PubMed Central

    Li, Hui; Weiss, William A.; Medved, Milica; Abe, Hiroyuki; Newstead, Gillian M.; Karczmar, Gregory S.; Giger, Maryellen L.

    2016-01-01

    Abstract. A three-dimensional breast density estimation method is presented for high spectral and spatial resolution (HiSS) MR imaging. Twenty-two patients were recruited (under an Institutional Review Board--approved Health Insurance Portability and Accountability Act-compliant protocol) for high-risk breast cancer screening. Each patient received standard-of-care clinical digital x-ray mammograms and MR scans, as well as HiSS scans. The algorithm for breast density estimation includes breast mask generating, breast skin removal, and breast percentage density calculation. The inter- and intra-user variabilities of the HiSS-based density estimation were determined using correlation analysis and limits of agreement. Correlation analysis was also performed between the HiSS-based density estimation and radiologists’ breast imaging-reporting and data system (BI-RADS) density ratings. A correlation coefficient of 0.91 (p<0.0001) was obtained between left and right breast density estimations. An interclass correlation coefficient of 0.99 (p<0.0001) indicated high reliability for the inter-user variability of the HiSS-based breast density estimations. A moderate correlation coefficient of 0.55 (p=0.0076) was observed between HiSS-based breast density estimations and radiologists’ BI-RADS. In summary, an objective density estimation method using HiSS spectral data from breast MRI was developed. The high reproducibility with low inter- and low intra-user variabilities shown in this preliminary study suggest that such a HiSS-based density metric may be potentially beneficial in programs requiring breast density such as in breast cancer risk assessment and monitoring effects of therapy. PMID:28042590

  3. Saving time and money: a validation of the self ratings on the prospective NIMH Life-Chart Method (NIMH-LCM).

    PubMed

    Born, Christoph; Amann, Benedikt L; Grunze, Heinz; Post, Robert M; Schärer, Lars

    2014-05-07

    Careful observation of the longitudinal course of bipolar disorders is pivotal to finding optimal treatments and improving outcome. A useful tool is the daily prospective Life-Chart Method, developed by the National Institute of Mental Health. However, it remains unclear whether the patient version is as valid as the clinician version. We compared the patient-rated version of the Lifechart (LC-self) with the Young-Mania-Rating Scale (YMRS), Inventory of Depressive Symptoms-Clinician version (IDS-C), and Clinical Global Impression-Bipolar version (CGI-BP) in 108 bipolar I and II patients who participated in the Naturalistic Follow-up Study (NFS) of the German centres of the Bipolar Collaborative Network (BCN; formerly Stanley Foundation Bipolar Network). For statistical evaluation, levels of severity of mood states on the Lifechart were transformed numerically and comparison with affective scales was performed using chi-square and t tests. For testing correlations Pearson´s coefficient was calculated. Ratings for depression of LC-self and total scores of IDS-C were found to be highly correlated (Pearson coefficient r = -.718; p < .001), whilst the correlation of ratings for mania with YMRS compared to LC-self were slightly less robust (Pearson coefficient r = .491; p = .001). These results were confirmed by good correlations between the CGI-BP IA (mania), IB (depression) and IC (overall mood state) and the LC-self ratings (Pearson coefficient r = .488, r = .721 and r = .65, respectively; all p < .001). The LC-self shows a significant correlation and good concordance with standard cross sectional affective rating scales, suggesting that the LC-self is a valid and time and money saving alternative to the clinician-rated version which should be incorporated in future clinical research in bipolar disorder. Generalizability of the results is limited by the selection of highly motivated patients in specialized bipolar centres and by the open design of the study.

  4. Correlated states of a quantum oscillator acted by short pulses

    NASA Technical Reports Server (NTRS)

    Manko, O. V.

    1993-01-01

    Correlated squeezed states for a quantum oscillator are constructed based on the method of quantum integrals of motion. The quantum oscillator is acted upon by short duration pulses. Three delta-kickings of frequency are used to model the pulses' dependence upon the time aspects of the frequency of the oscillator. Additionally, the correlation coefficient and quantum variances of operations of coordinates and momenta are written in explicit form.

  5. Statistical methods for astronomical data with upper limits. II - Correlation and regression

    NASA Technical Reports Server (NTRS)

    Isobe, T.; Feigelson, E. D.; Nelson, P. I.

    1986-01-01

    Statistical methods for calculating correlations and regressions in bivariate censored data where the dependent variable can have upper or lower limits are presented. Cox's regression and the generalization of Kendall's rank correlation coefficient provide significant levels of correlations, and the EM algorithm, under the assumption of normally distributed errors, and its nonparametric analog using the Kaplan-Meier estimator, give estimates for the slope of a regression line. Monte Carlo simulations demonstrate that survival analysis is reliable in determining correlations between luminosities at different bands. Survival analysis is applied to CO emission in infrared galaxies, X-ray emission in radio galaxies, H-alpha emission in cooling cluster cores, and radio emission in Seyfert galaxies.

  6. Development and validation of a Semi-quantitative food frequency questionnaire among older people in north of Iran

    PubMed Central

    Bijani, Ali; Esmaili, Haleh; Ghadimi, Reza; Babazadeh, Atekeh; Rezaei, Reyhaneh; G Cumming, Robert; Hosseini, Seyed Reza

    2018-01-01

    Background: The study was conducted to assess reliability of modified semi-quantitative food frequency questionnaire (SQFFQ) as a part of the Amirkola Health and Aging Project (AHAP). Methods: The study was carried out in a sample of 200 men and women aged 60 years and older. A 138-item SQFFQ and two 24-hour dietary recalls were completed. The reliability of SQFFQ was evaluated by comparing eighteen food groups, energy and nutrient intakes derived from both methods using Spearman and Pearson’s correlation coefficients for food groups and nutrients, respectively. Bland-Altman plots and Pitman’s tests were applied to compare the two dietary assessment methods. Results: The mean (SD) age of subjects was 68.16 (6.56) years. The average energy intake from 24-hour dietary recalls and the SQFFQ were 1470.2 and 1535.4 kcal/day, respectively. Spearman correlation coefficients, comparing food groups intake based on two dietary assessment methods ranged from 0.25 (meat) to 0.62 (tea and coffee) in men and from 0.39 (whole grains) to 0.60 (sugars) in women. Pearson correlation coefficients for energy and macronutrients were 0.53 for energy to 0.21 for zinc in male and 0.71 for energy to 0.26 for vitamin C in females. The Pitman’s test reflected the reasonable agreement between the mean energy and macronutrients of the SQFFQ and 24-hour recalls. Conclusions: The modified SQFFQ that was designed for the AHAP was found to be reliable for assessing the intake of several food groups, energy, micro-and macronutrients. PMID:29387324

  7. Price-volume multifractal analysis of the Moroccan stock market

    NASA Astrophysics Data System (ADS)

    El Alaoui, Marwane

    2017-11-01

    In this paper, we analyzed price-volume multifractal cross-correlations of Moroccan Stock Exchange. We chose the period from January 1st 2000 to January 20th 2017 to investigate the multifractal behavior of price change and volume change series. Then, we used multifractal detrended cross-correlations analysis method (MF-DCCA) and multifractal detrended fluctuation analysis (MF-DFA) to analyze the series. We computed bivariate generalized Hurst exponent, Rényi exponent and spectrum of singularity for each pair of indices to measure quantitatively cross-correlations. Furthermore, we used detrended cross-correlations coefficient (DCCA) and cross-correlation test (Q(m)) to analyze cross-correlation quantitatively and qualitatively. By analyzing results, we found existence of price-volume multifractal cross-correlations. The spectrum width has a strong multifractal cross-correlation. We remarked that volume change series is anti-persistent when we analyzed the generalized Hurst exponent for all moments q. The cross-correlation test showed the presence of a significant cross-correlation. However, DCCA coefficient had a small positive value, which means that the level of correlation is not very significant. Finally, we analyzed sources of multifractality and their degree of contribution in the series.

  8. Testing a single regression coefficient in high dimensional linear models

    PubMed Central

    Zhong, Ping-Shou; Li, Runze; Wang, Hansheng; Tsai, Chih-Ling

    2017-01-01

    In linear regression models with high dimensional data, the classical z-test (or t-test) for testing the significance of each single regression coefficient is no longer applicable. This is mainly because the number of covariates exceeds the sample size. In this paper, we propose a simple and novel alternative by introducing the Correlated Predictors Screening (CPS) method to control for predictors that are highly correlated with the target covariate. Accordingly, the classical ordinary least squares approach can be employed to estimate the regression coefficient associated with the target covariate. In addition, we demonstrate that the resulting estimator is consistent and asymptotically normal even if the random errors are heteroscedastic. This enables us to apply the z-test to assess the significance of each covariate. Based on the p-value obtained from testing the significance of each covariate, we further conduct multiple hypothesis testing by controlling the false discovery rate at the nominal level. Then, we show that the multiple hypothesis testing achieves consistent model selection. Simulation studies and empirical examples are presented to illustrate the finite sample performance and the usefulness of the proposed method, respectively. PMID:28663668

  9. Testing a single regression coefficient in high dimensional linear models.

    PubMed

    Lan, Wei; Zhong, Ping-Shou; Li, Runze; Wang, Hansheng; Tsai, Chih-Ling

    2016-11-01

    In linear regression models with high dimensional data, the classical z -test (or t -test) for testing the significance of each single regression coefficient is no longer applicable. This is mainly because the number of covariates exceeds the sample size. In this paper, we propose a simple and novel alternative by introducing the Correlated Predictors Screening (CPS) method to control for predictors that are highly correlated with the target covariate. Accordingly, the classical ordinary least squares approach can be employed to estimate the regression coefficient associated with the target covariate. In addition, we demonstrate that the resulting estimator is consistent and asymptotically normal even if the random errors are heteroscedastic. This enables us to apply the z -test to assess the significance of each covariate. Based on the p -value obtained from testing the significance of each covariate, we further conduct multiple hypothesis testing by controlling the false discovery rate at the nominal level. Then, we show that the multiple hypothesis testing achieves consistent model selection. Simulation studies and empirical examples are presented to illustrate the finite sample performance and the usefulness of the proposed method, respectively.

  10. Analysis of diffusion and binding in cells using the RICS approach.

    PubMed

    Digman, Michelle A; Gratton, Enrico

    2009-04-01

    The movement of macromolecules in cells is assumed to occur either through active transport or by diffusion. However, the determination of the diffusion coefficients in cells using fluctuation methods or FRAP frequently give diffusion coefficient that are orders of magnitude smaller than the diffusion coefficients measured for the same macromolecule in solution. It is assumed that the cell internal viscosity is partially responsible for this decrease in the apparent diffusion. When the apparent diffusion is too slow to be due to cytoplasm viscosity, it is assumed that weak binding of the macromolecules to immobile or quasi immobile structures is taking place. In this article, we derive equations for fitting of the RICS (Raster-scan Image Correlations Spectroscopy) data in cells to a model that includes transient binding to immobile structures, and we show that under some conditions, the spatio-temporal correlation provided by the RICS approach can distinguish the process of diffusion and weak binding. We apply the method to determine the diffusion in the cytoplasm and binding of Focal Adhesion Kinase-EGFP to adhesions in MEF cells.

  11. Bivariate functional data clustering: grouping streams based on a varying coefficient model of the stream water and air temperature relationship

    Treesearch

    H. Li; X. Deng; Andy Dolloff; E. P. Smith

    2015-01-01

    A novel clustering method for bivariate functional data is proposed to group streams based on their water–air temperature relationship. A distance measure is developed for bivariate curves by using a time-varying coefficient model and a weighting scheme. This distance is also adjusted by spatial correlation of streams via the variogram. Therefore, the proposed...

  12. Correlations among measures of knee stiffness, gait performance and complaints in individuals with knee osteoarthritis.

    PubMed

    Oatis, Carol A; Wolff, Edward F; Lockard, Margery A; Michener, Lori A; Robbins, Steven J

    2013-03-01

    Stiffness is a common complaint in individuals with knee osteoarthritis and is a component of the osteoarthritis diagnosis. Yet the relationship between stiffness and function is poorly understood and methods to quantify stiffness are limited. Using a cross-sectional observational design with 66 subjects with knee osteoarthritis, stiffness and damping coefficients were calculated from a relaxed knee oscillation procedure. Gait parameters were measured using an electronic walkway. Self-reported pain, stiffness, and function were measured with the Western Ontario and McMaster Osteoarthritis Index. Correlation and Alexander's normalized-t approximation analyses were used to assess associations among the variables. Subset analysis was performed on subjects with and without tibiofemoral joint crepitus. Slight to moderate correlations existed between stiffness and damping coefficients and most gait parameters ((| r |=0.30-0.56; P<.05) and between Western Ontario and McMaster Osteoarthritis Index scores and all gait parameters (| r |=0.35-0.62; P<.05). The damping coefficient was only slightly associated with patient-rated Western Ontario and McMaster Osteoarthritis Index stiffness subscale scores. Subset analysis revealed significant correlations that differed between those with and without crepitus. These findings suggest that laboratory measured stiffness and damping coefficients, Western Ontario and McMaster Osteoarthritis Index scores and gait-related measurements assess different aspects related to movement in individuals with knee osteoarthritis. Stiffness and damping coefficients may offer the ability to explain gait changes in the knee that are independent of a person's perceptions particularly in the early stages of the disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. More accurate, calibrated bootstrap confidence intervals for correlating two autocorrelated climate time series

    NASA Astrophysics Data System (ADS)

    Olafsdottir, Kristin B.; Mudelsee, Manfred

    2013-04-01

    Estimation of the Pearson's correlation coefficient between two time series to evaluate the influences of one time depended variable on another is one of the most often used statistical method in climate sciences. Various methods are used to estimate confidence interval to support the correlation point estimate. Many of them make strong mathematical assumptions regarding distributional shape and serial correlation, which are rarely met. More robust statistical methods are needed to increase the accuracy of the confidence intervals. Bootstrap confidence intervals are estimated in the Fortran 90 program PearsonT (Mudelsee, 2003), where the main intention was to get an accurate confidence interval for correlation coefficient between two time series by taking the serial dependence of the process that generated the data into account. However, Monte Carlo experiments show that the coverage accuracy for smaller data sizes can be improved. Here we adapt the PearsonT program into a new version called PearsonT3, by calibrating the confidence interval to increase the coverage accuracy. Calibration is a bootstrap resampling technique, which basically performs a second bootstrap loop or resamples from the bootstrap resamples. It offers, like the non-calibrated bootstrap confidence intervals, robustness against the data distribution. Pairwise moving block bootstrap is used to preserve the serial correlation of both time series. The calibration is applied to standard error based bootstrap Student's t confidence intervals. The performances of the calibrated confidence intervals are examined with Monte Carlo simulations, and compared with the performances of confidence intervals without calibration, that is, PearsonT. The coverage accuracy is evidently better for the calibrated confidence intervals where the coverage error is acceptably small (i.e., within a few percentage points) already for data sizes as small as 20. One form of climate time series is output from numerical models which simulate the climate system. The method is applied to model data from the high resolution ocean model, INALT01 where the relationship between the Agulhas Leakage and the North Brazil Current is evaluated. Preliminary results show significant correlation between the two variables when there is 10 year lag between them, which is more or less the time that takes the Agulhas Leakage water to reach the North Brazil Current. Mudelsee, M., 2003. Estimating Pearson's correlation coefficient with bootstrap confidence interval from serially dependent time series. Mathematical Geology 35, 651-665.

  14. Three-dimensional quantitative structure-activity relationship studies on c-Src inhibitors based on different docking methods.

    PubMed

    Bairy, Santhosh Kumar; Suneel Kumar, B V S; Bhalla, Joseph Uday Tej; Pramod, A B; Ravikumar, Muttineni

    2009-04-01

    c-Src kinase play an important role in cell growth and differentiation and its inhibitors can be useful for the treatment of various diseases, including cancer, osteoporosis, and metastatic bone disease. Three dimensional quantitative structure-activity relationship (3D-QSAR) studies were carried out on quinazolin derivatives inhibiting c-Src kinase. Molecular field analysis (MFA) models with four different alignment techniques, namely, GLIDE, GOLD, LIGANDFIT and Least squares based methods were developed. glide based MFA model showed better results (Leave one out cross validation correlation coefficient r(2)(cv) = 0.923 and non-cross validation correlation coefficient r(2)= 0.958) when compared with other models. These results help us to understand the nature of descriptors required for activity of these compounds and thereby provide guidelines to design novel and potent c-Src kinase inhibitors.

  15. The Effect of a Fluorophore Photo-Physics on the Lipid Vesicle Diffusion Coefficient Studied by Fluorescence Correlation Spectroscopy.

    PubMed

    Drabik, Dominik; Przybyło, Magda; Sikorski, Aleksander; Langner, Marek

    2016-03-01

    Fluorescence Correlation Spectroscopy (FCS) is a technique, which allows determination of the diffusion coefficient and concentration of fluorescent objects suspended in the solution. The measured parameter is the fluctuation of the fluorescence signal emitted by diffusing molecules. When 100 nm DOPC vesicles labeled with various fluorescent dyes (Fluorescein-PE, NBD-PE, Atto488 DOPE or βBodipy FL) were measured, different values of diffusion coefficients have been obtained. These diffusion coefficients were different from the expected values measured using the dynamic light scattering method (DLS). The FCS was initially developed for solutions containing small fluorescent molecules therefore the observed inconsistency may result from the nature of vesicle suspension itself. The duration of the fluorescence signal may depend on the following factors: the exposure time of the labeled object to the excitation beam, the photo-physical properties (e.g., stability) of a fluorophore, the theoretical model used for the calculations of the diffusion coefficient and optical properties of the vesicle suspension. The diffusion coefficients determined for differently labeled liposomes show that its dependence on vesicle size and quantity of fluorescent probed used for labeling was significant demonstrating that the fluorescence properties of the fluorophore itself (bleaching and/or blinking) were critical factors for a correct outcome of FCS experiment. The new, based on combined FCS and DLS measurements, method for the determination of the focal volume prove itself to be useful for the evaluation of a fluorescence dye with respect to its applicability for FCS experiment.

  16. Real-time measurements of airborne biologic particles using fluorescent particle counter to evaluate microbial contamination: results of a comparative study in an operating theater.

    PubMed

    Dai, Chunyang; Zhang, Yan; Ma, Xiaoling; Yin, Meiling; Zheng, Haiyang; Gu, Xuejun; Xie, Shaoqing; Jia, Hengmin; Zhang, Liang; Zhang, Weijun

    2015-01-01

    Airborne bacterial contamination poses a risk for surgical site infection, and routine surveillance of airborne bacteria is important. Traditional methods for detecting airborne bacteria are time consuming and strenuous. Measurement of biologic particle concentrations using a fluorescent particle counter is a novel method for evaluating air quality. The current study was to determine whether the number of biologic particles detected by the fluorescent particle counter can be used to indicate airborne bacterial counts in operating rooms. The study was performed in an operating theater at a university hospital in Hefei, China. The number of airborne biologic particles every minute was quantified using a fluorescent particle counter. Microbiologic air sampling was performed every 30 minutes using an Andersen air sampler (Pusong Electronic Instruments, Changzhou, China). Correlations between the 2 different methods were analyzed by Pearson correlation coefficients. A significant correlation was observed between biologic particle and bacterial counts (Pearson correlation coefficient = 0.76), and the counting results from 2 methods both increased substantially between operations, corresponding with human movements in the operating room. Fluorescent particle counters show potential as important tools for monitoring bacterial contamination in operating theatres. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. Direct and simultaneous detection of organic and inorganic ingredients in herbal powder preparations by Fourier transform infrared microspectroscopic imaging

    NASA Astrophysics Data System (ADS)

    Chen, Jian-bo; Sun, Su-qin; Tang, Xu-dong; Zhang, Jing-zhao; Zhou, Qun

    2016-08-01

    Herbal powder preparation is a kind of widely-used herbal product in the form of powder mixture of herbal ingredients. Identification of herbal ingredients is the first and foremost step in assuring the quality, safety and efficacy of herbal powder preparations. In this research, Fourier transform infrared (FT-IR) microspectroscopic identification method is proposed for the direct and simultaneous recognition of multiple organic and inorganic ingredients in herbal powder preparations. First, the reference spectrum of characteristic particles of each herbal ingredient is assigned according to FT-IR results and other available information. Next, a statistical correlation threshold is determined as the lower limit of correlation coefficients between the reference spectrum and a larger number of calibration characteristic particles. After validation, the reference spectrum and correlation threshold can be used to identify herbal ingredient in mixture preparations. A herbal ingredient is supposed to be present if correlation coefficients between the reference spectrum and some sample particles are above the threshold. Using this method, all kinds of herbal materials in powder preparation Kouqiang Kuiyang San are identified successfully. This research shows the potential of FT-IR microspectroscopic identification method for the accurate and quick identification of ingredients in herbal powder preparations.

  18. ppcor: An R Package for a Fast Calculation to Semi-partial Correlation Coefficients.

    PubMed

    Kim, Seongho

    2015-11-01

    Lack of a general matrix formula hampers implementation of the semi-partial correlation, also known as part correlation, to the higher-order coefficient. This is because the higher-order semi-partial correlation calculation using a recursive formula requires an enormous number of recursive calculations to obtain the correlation coefficients. To resolve this difficulty, we derive a general matrix formula of the semi-partial correlation for fast computation. The semi-partial correlations are then implemented on an R package ppcor along with the partial correlation. Owing to the general matrix formulas, users can readily calculate the coefficients of both partial and semi-partial correlations without computational burden. The package ppcor further provides users with the level of the statistical significance with its test statistic.

  19. Endocrine disruptor & nutritional effects of heavy metals in ovarian hyperstimulation.

    PubMed

    Dickerson, E H; Sathyapalan, T; Knight, R; Maguiness, S M; Killick, S R; Robinson, J; Atkin, S L

    2011-12-01

    There is increasing concern that environmental chemicals have a direct effect on fertility. Heavy metals such as mercury have been shown to affect various organ systems in humans including nervous system and skin, however they could also act as endocrine disrupting chemicals adversely affecting fertility. Metals such as zinc and selenium are essential micronutrients with diverse functions that may be important for reproductive outcomes. We measured mercury, zinc and selenium levels in the hair, a reliable reflection of long term environmental exposure and dietary status, to correlate with the outcome of ovarian hyperstimulation for in vitro fertilisation (IVF) treatment. We analysed the hair of 30 subfertile women for mercury, zinc and selenium using inductively coupled mass spectrometry. Each woman underwent one cycle of IVF treatment. Correlation between the levels of these trace metals and treatment outcomes was investigated. Thirty women were recruited with mean (±SD) age of 32.7(4.4) years and BMI of 25.4(5.0)kg/m(2). Hair mercury concentration showed a negative correlation with oocyte yield (p < 0.05,βcoefficient 0.38) and follicle number (p = 0.03,β coefficient0.19) after ovarian stimulation. Zinc and selenium levels in hair correlated positively with oocyte yield after ovarian stimulation (p < 0.05,β coefficient0.15) and (p = 0.03,β coefficient0.21) respectively. Selenium levels in hair correlated significantly with follicle number following stimulation (p = 0.04, βcoefficient0.22). There was no correlation between mercury, zinc and selenium in hair and their corresponding serum levels. These data suggest that mercury had a deleterious effect whilst there was a positive effect for zinc and selenium in the ovarian response to gonadotrophin therapy for IVF. Hair analysis offers a novel method of investigating the impact of long-term exposure to endocrine disruptors and nutritional status on reproductive outcomes.

  20. Validation of a quantitative Eimeria spp. PCR for fresh droppings of broiler chickens.

    PubMed

    Peek, H W; Ter Veen, C; Dijkman, R; Landman, W J M

    2017-12-01

    A quantitative Polymerase Chain Reaction (qPCR) for the seven chicken Eimeria spp. was modified and validated for direct use on fresh droppings. The analytical specificity of the qPCR on droppings was 100%. Its analytical sensitivity (non-sporulated oocysts/g droppings) was 41 for E. acervulina, ≤2900 for E. brunetti, 710 for E. praecox, 1500 for E. necatrix, 190 for E. tenella, 640 for E. maxima, and 1100 for E. mitis. Field validation of the qPCR was done using droppings with non-sporulated oocysts from 19 broiler flocks. To reduce the number of qPCR tests five grams of each pooled sample (consisting of ten fresh droppings) per time point were blended into one mixed sample. Comparison of the oocysts per gram (OPG)-counting method with the qPCR using pooled samples (n = 1180) yielded a Pearson's correlation coefficient of 0.78 (95% CI: 0.76-0.80) and a Pearson's correlation coefficient of 0.76 (95% CI: 0.70-0.81) using mixed samples (n = 236). Comparison of the average of the OPG-counts of the five pooled samples with the mixed sample per time point (n = 236) showed a Pearson's correlation coefficient (R) of 0.94 (95% CI: 0.92-0.95) for the OPG-counting method and 0.87 (95% CI: 0.84-0.90) for the qPCR. This indicates that mixed samples are practically equivalent to the mean of five pooled samples. The good correlation between the OPG-counting method and the qPCR was further confirmed by the visual agreement between the total oocyst/g shedding patterns measured with both techniques in the 19 broiler flocks using the mixed samples.

  1. Comparison of methods to evaluate the fungal biomass in heating, ventilation, and air-conditioning (HVAC) dust.

    PubMed

    Biyeyeme Bi Mve, Marie-Jeanne; Cloutier, Yves; Lacombe, Nancy; Lavoie, Jacques; Debia, Maximilien; Marchand, Geneviève

    2016-12-01

    Heating, ventilation, and air-conditioning (HVAC) systems contain dust that can be contaminated with fungal spores (molds), which may have harmful effects on the respiratory health of the occupants of a building. HVAC cleaning is often based on visual inspection of the quantity of dust, without taking the mold content into account. The purpose of this study is to propose a method to estimate fungal contamination of dust in HVAC systems. Comparisons of different analytical methods were carried out on dust deposited in a controlled-atmosphere exposure chamber. Sixty samples were analyzed using four methods: culture, direct microscopic spore count (DMSC), β-N-acetylhexosaminidase (NAHA) dosing and qPCR. For each method, the limit of detection, replicability, and repeatability were assessed. The Pearson correlation coefficients between the methods were also evaluated. Depending on the analytical method, mean spore concentrations per 100 cm 2 of dust ranged from 10,000 to 682,000. Limits of detection varied from 120 to 217,000 spores/100 cm 2 . Replicability and repeatability were between 1 and 15%. Pearson correlation coefficients varied from -0.217 to 0.83. The 18S qPCR showed the best sensitivity and precision, as well as the best correlation with the culture method. PCR targets only molds, and a total count of fungal DNA is obtained. Among the methods, mold DNA amplification by qPCR is the method suggested for estimating the fungal content found in dust of HVAC systems.

  2. Introduction of Total Variation Regularization into Filtered Backprojection Algorithm

    NASA Astrophysics Data System (ADS)

    Raczyński, L.; Wiślicki, W.; Klimaszewski, K.; Krzemień, W.; Kowalski, P.; Shopa, R. Y.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B.; Jasińska, B.; Kisielewska-Kamińska, D.; Korcyl, G.; Kozik, T.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Niedźwiecki, S.; Pałka, M.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.

  3. Relationships among the slopes of lines derived from various data analysis techniques and the associated correlation coefficient

    NASA Technical Reports Server (NTRS)

    Cohen, S. C.

    1980-01-01

    A technique for fitting a straight line to a collection of data points is given. The relationships between the slopes and correlation coefficients, and between the corresponding standard deviations and correlation coefficient are given.

  4. Aggregation of carbon dioxide sequestration storage assessment units

    USGS Publications Warehouse

    Blondes, Madalyn S.; Schuenemeyer, John H.; Olea, Ricardo A.; Drew, Lawrence J.

    2013-01-01

    The U.S. Geological Survey is currently conducting a national assessment of carbon dioxide (CO2) storage resources, mandated by the Energy Independence and Security Act of 2007. Pre-emission capture and storage of CO2 in subsurface saline formations is one potential method to reduce greenhouse gas emissions and the negative impact of global climate change. Like many large-scale resource assessments, the area under investigation is split into smaller, more manageable storage assessment units (SAUs), which must be aggregated with correctly propagated uncertainty to the basin, regional, and national scales. The aggregation methodology requires two types of data: marginal probability distributions of storage resource for each SAU, and a correlation matrix obtained by expert elicitation describing interdependencies between pairs of SAUs. Dependencies arise because geologic analogs, assessment methods, and assessors often overlap. The correlation matrix is used to induce rank correlation, using a Cholesky decomposition, among the empirical marginal distributions representing individually assessed SAUs. This manuscript presents a probabilistic aggregation method tailored to the correlations and dependencies inherent to a CO2 storage assessment. Aggregation results must be presented at the basin, regional, and national scales. A single stage approach, in which one large correlation matrix is defined and subsets are used for different scales, is compared to a multiple stage approach, in which new correlation matrices are created to aggregate intermediate results. Although the single-stage approach requires determination of significantly more correlation coefficients, it captures geologic dependencies among similar units in different basins and it is less sensitive to fluctuations in low correlation coefficients than the multiple stage approach. Thus, subsets of one single-stage correlation matrix are used to aggregate to basin, regional, and national scales.

  5. [Research on rapid and quantitative detection method for organophosphorus pesticide residue].

    PubMed

    Sun, Yuan-Xin; Chen, Bing-Tai; Yi, Sen; Sun, Ming

    2014-05-01

    The methods of physical-chemical inspection is adopted in the traditional pesticide residue detection, which require a lot of pretreatment processes, are time-consuming and complicated. In the present study, the authors take chlorpyrifos applied widely in the present agricultural field as the research object and propose a rapid and quantitative detection method for organophosphorus pesticide residues. At first, according to the chemical characteristics of chlorpyrifos and comprehensive chromogenic effect of several colorimetric reagents and secondary pollution, the pretreatment of the scheme of chromogenic reaction of chlorpyrifos with resorcin in a weak alkaline environment was determined. Secondly, by analyzing Uv-Vis spectrum data of chlorpyrifos samples whose content were between 0. 5 and 400 mg kg-1, it was confirmed that the characteristic information after the color reaction mainly was concentrated among 360 approximately 400 nm. Thirdly, the full spectrum forecasting model was established based on the partial least squares, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 995 6, standard deviation of calibration (RMSEC) was 2. 814 7 mg kg-1, and standard deviation of verification (RMSEP) was 8. 012 4 mg kg-1. Fourthly, the wavelengths whose center wavelength is 400 nm was extracted as characteristic region to build a forecasting model, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 999 3, standard deviation of calibration (RMSEC) was 2. 566 7 mg kg-1 , standard deviation of verification (RMSEP) was 4. 886 6 mg kg-1, respectively. At last, by analyzing the near infrared spectrum data of chlorpyrifos samples with contents between 0. 5 and 16 mg kg-1, the authors found that although the characteristics of the chromogenic functional group are not obvious, the change of absorption peaks of resorcin itself in the neighborhood of 5 200 cm-' happens. The above-mentioned experimental results show that the proposed method is effective and feasible for rapid and quantitative detection prediction for organophosphorus pesticide residues. In the method, the information in full spectrum especially UV-Vis spectrum is strengthened by chromogenic reaction of a colorimetric reagent, which provides a new way of rapid detection of pesticide residues for agricultural products in the future.

  6. The Association Between Self-Rated Fitness and Cardiorespiratory Fitness in Adults.

    PubMed

    Jensen, Karina Gregersen; Rosthøj, Susanne; Linneberg, Allan; Aadahl, Mette

    2018-06-01

    To assess criterion validity of a single item question on self-rated physical fitness against objectively measured cardiorespiratory fitness. From the Health2008 study 749 men and women between 30 and 60 years of age rated their fitness as excellent, very good, good, fair or poor. Cardiorespiratory fitness was estimated with the watt-max test. Agreement between self-rated and objectively measured physical fitness was assessed by Cohen's weighted kappa coefficient. Correlation was determined by Goodman & Kruskal's gamma correlation coefficient. All analyses were stratified according to gender. Data from 323 men and 426 women were analysed. There was a slight agreement between self-rated and objectively measured fitness in men (weighted kappa: 0.18, [95%CI: 0.13;0.23]) and a fair agreement in women (weighted kappa: 0.27, [95%CI: 0.22;0.32]). In both genders, self-rated fitness was positively correlated with objectively measured fitness (moderate correlation; gamma correlation coefficient for men: 0.63 [95%CI: 0.54;0.72] and women: 0.67 [95%CI: 0.59;0.75]). There was a slight to fair agreement and moderate, positive correlations between self-rated physical fitness and watt-max estimated cardiorespiratory fitness. Hence, a single-item question on physical fitness may be a cost-effective method of assessing fitness in large population studies, but is not valid for individual assessments. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Knee joint stiffness in individuals with and without knee osteoarthritis: a preliminary study.

    PubMed

    Oatis, Carol A; Wolff, Edward F; Lennon, Sandra K

    2006-12-01

    Descriptive, case-matched comparison. To compare the knee joint stiffness and damping coefficients of individuals with knee osteoarthritis (KOA) to those of age- and gender-matched individuals without KOA. A secondary purpose was to investigate relationships between these coefficients and complaints of stiffness in individuals with KOA. KOA is a leading cause of disability, and stiffness is a common complaint in individuals with KOA. Yet the most common method of assessing knee joint stiffness is through a self-report questionnaire. Stiffness and damping coefficients at the knee were calculated in 10 volunteers (mean age +/- SD, 64.1+/-15.5 years) with KOA and compared to coefficients from age-and gender-matched individuals without KOA, collected in a previous study (mean age +/- SD, 62.1+/-13.9 years). Stiffness and damping coefficients were calculated from the angular motion of the knee during a relaxed oscillation. Spearman correlation coefficients were calculated between stiffness and damping coefficients and WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) scores for subjects with KOA. Independent 2-tailed t tests revealed significantly larger damping coefficients (P = .035) among those with KOA (95% CI, 0.10-2.32 Nm s/rad). Spearman rank correlations revealed a significant positive relationship (r = .85, P = .003) between the damping coefficient and the stiffness subscore of the WOMAC. This study offers preliminary data demonstrating the feasibility of measuring stiffness and damping coefficients in individuals with KOA. Additionally, the damping coefficient is increased in people with KOA when compared to age- and gender-matched individuals without KOA. The damping coefficient appears to be associated with the complaints of stiffness reported by the WOMAC.

  8. Correlation Between Minimum Apparent Diffusion Coefficient (ADCmin) and Tumor Cellularity: A Meta-analysis.

    PubMed

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2017-07-01

    Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique based on measure of water diffusion that can provide information about tissue microstructure, especially about cell count. Increase of cell density induces restriction of water diffusion and decreases apparent diffusion coefficient (ADC). ADC can be divided into three sub-parameters: ADC minimum or ADC min , mean ADC or ADC mean and ADC maximum or ADC max Some studies have suggested that ADC min shows stronger correlations with cell count in comparison to other ADC fractions and may be used as a parameter for estimation of tumor cellularity. The aim of the present meta-analysis was to summarize correlation coefficients between ADC min and cellularity in different tumors based on large patient data. For this analysis, MEDLINE database was screened for associations between ADC and cell count in different tumors up to September 2016. For this work, only data regarding ADC min were included. Overall, 12 publications with 317 patients were identified. Spearman's correlation coefficient was used to analyze associations between ADC min and cellularity. The reported Pearson correlation coefficients in some publications were converted into Spearman correlation coefficients. The pooled correlation coefficient for all included studies was ρ=-0.59 (95% confidence interval (CI)=-0.72 to -0.45), heterogeneity Tau 2 =0.04 (p<0.0001), I 2 =73%, test for overall effect Z=8.67 (p<0.00001). ADC min correlated moderately with tumor cellularity. The calculated correlation coefficient is not stronger in comparison to the reported coefficient for ADC mean and, therefore, ADC min does not represent a better means to reflect cellularity. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  9. Predicting cyclohexane/water distribution coefficients for the SAMPL5 challenge using MOSCED and the SMD solvation model

    NASA Astrophysics Data System (ADS)

    Diaz-Rodriguez, Sebastian; Bozada, Samantha M.; Phifer, Jeremy R.; Paluch, Andrew S.

    2016-11-01

    We present blind predictions using the solubility parameter based method MOSCED submitted for the SAMPL5 challenge on calculating cyclohexane/water distribution coefficients at 298 K. Reference data to parameterize MOSCED was generated with knowledge only of chemical structure by performing solvation free energy calculations using electronic structure calculations in the SMD continuum solvent. To maintain simplicity and use only a single method, we approximate the distribution coefficient with the partition coefficient of the neutral species. Over the final SAMPL5 set of 53 compounds, we achieved an average unsigned error of 2.2± 0.2 log units (ranking 15 out of 62 entries), the correlation coefficient ( R) was 0.6± 0.1 (ranking 35), and 72± 6 % of the predictions had the correct sign (ranking 30). While used here to predict cyclohexane/water distribution coefficients at 298 K, MOSCED is broadly applicable, allowing one to predict temperature dependent infinite dilution activity coefficients in any solvent for which parameters exist, and provides a means by which an excess Gibbs free energy model may be parameterized to predict composition dependent phase-equilibrium.

  10. Quantitative correlations between collision induced dissociation mass spectrometry coupled with electrospray ionization or atmospheric pressure chemical ionization mass spectrometry - Experiment and theory

    NASA Astrophysics Data System (ADS)

    Ivanova, Bojidarka; Spiteller, Michael

    2018-04-01

    The problematic that we consider in this paper treats the quantitative correlation model equations between experimental kinetic and thermodynamic parameters of coupled electrospray ionization (ESI) mass spectrometry (MS) or atmospheric pressure chemical ionization (APCI) mass spectrometry with collision induced dissociation mass spectrometry, accounting for the fact that the physical phenomena and mechanisms of ESI- and APCI-ion formation are completely different. There are described forty two fragment reactions of three analytes under independent ESI- and APCI-measurements. The developed new quantitative models allow us to study correlatively the reaction kinetics and thermodynamics using the methods of mass spectrometry, which complementary application with the methods of the quantum chemistry provide 3D structural information of the analytes. Both static and dynamic quantum chemical computations are carried out. The object of analyses are [2,3-dimethyl-4-(4-methyl-benzoyl)-2,3-di-p-tolyl-cyclobutyl]-p-tolyl-methanone (1) and the polycyclic aromatic hydrocarbons derivatives of dibenzoperylen (2) and tetrabenzo [a,c,fg,op]naphthacene (3), respectively. As far as (1) is known to be a product of [2π+2π] cycloaddition reactions of chalcone (1,3-di-p-tolyl-propenone), however producing cyclic derivatives with different stereo selectivity, so that the study provide crucial data about the capability of mass spectrometry to provide determine the stereo selectivity of the analytes. This work also first provides quantitative treatment of the relations '3D molecular/electronic structures'-'quantum chemical diffusion coefficient'-'mass spectrometric diffusion coefficient', thus extending the capability of the mass spectrometry for determination of the exact 3D structure of the analytes using independent measurements and computations of the diffusion coefficients. The determination of the experimental diffusion parameters is carried out within the 'current monitoring method' evaluating the translation diffusion of charged analytes, while the theoretical modelling of MS ions and computations of theoretical diffusion coefficients are based on the Arrhenius type behavior of the charged species under ESI- and APCI-conditions. Although the study provide certain sound considerations for the quantitative relations between the reaction kinetic-thermodynamics and 3D structure of the analytes together with correlations between 3D molecular/electronic structures-quantum chemical diffusion coefficient-mass spectrometric diffusion coefficient, which contribute significantly to the structural analytical chemistry, the results have importance to other areas such as organic synthesis and catalysis as well.

  11. Correlation of human papillomavirus status with apparent diffusion coefficient of diffusion-weighted MRI in head and neck squamous cell carcinomas.

    PubMed

    Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P

    2016-04-01

    Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.

  12. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures

    PubMed Central

    Someswara Rao, Chinta; Viswanadha Raju, S.

    2016-01-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc. PMID:26981409

  13. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures.

    PubMed

    Someswara Rao, Chinta; Viswanadha Raju, S

    2016-03-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc.

  14. R package to estimate intracluster correlation coefficient with confidence interval for binary data.

    PubMed

    Chakraborty, Hrishikesh; Hossain, Akhtar

    2018-03-01

    The Intracluster Correlation Coefficient (ICC) is a major parameter of interest in cluster randomized trials that measures the degree to which responses within the same cluster are correlated. There are several types of ICC estimators and its confidence intervals (CI) suggested in the literature for binary data. Studies have compared relative weaknesses and advantages of ICC estimators as well as its CI for binary data and suggested situations where one is advantageous in practical research. The commonly used statistical computing systems currently facilitate estimation of only a very few variants of ICC and its CI. To address the limitations of current statistical packages, we developed an R package, ICCbin, to facilitate estimating ICC and its CI for binary responses using different methods. The ICCbin package is designed to provide estimates of ICC in 16 different ways including analysis of variance methods, moments based estimation, direct probabilistic methods, correlation based estimation, and resampling method. CI of ICC is estimated using 5 different methods. It also generates cluster binary data using exchangeable correlation structure. ICCbin package provides two functions for users. The function rcbin() generates cluster binary data and the function iccbin() estimates ICC and it's CI. The users can choose appropriate ICC and its CI estimate from the wide selection of estimates from the outputs. The R package ICCbin presents very flexible and easy to use ways to generate cluster binary data and to estimate ICC and it's CI for binary response using different methods. The package ICCbin is freely available for use with R from the CRAN repository (https://cran.r-project.org/package=ICCbin). We believe that this package can be a very useful tool for researchers to design cluster randomized trials with binary outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Correlation of Zn2+ content with aflatoxin content of corn.

    PubMed Central

    Failla, L J; Lynn, D; Niehaus, W G

    1986-01-01

    Forty-nine samples from the 1983 Virginia corn harvest were analyzed for aflatoxin, zinc, copper, iron, and manganese content. Values (mean +/- standard deviation) were as follows: aflatoxin, 117 +/- 360 micrograms/kg; zinc, 22.5 +/- 3.4 mg/kg; copper, 2.27 +/- 0.56 mg/kg; iron, 40.8 +/- 18.7 mg/kg; and manganese, 5.1 +/- 1.1 mg/kg. Aflatoxin levels positively correlated with zinc (Spearman correlation coefficient, 0.385; P less than 0.006) and copper levels (Spearman correlation coefficient, 0.573; P less than 0.0001). Based on biochemical data in the literature, we believe that the correlation with zinc is important and that there may be a cause-and-effect relationship between zinc levels in corn and aflatoxin levels which are produced upon infection with Aspergillus flavus or A. parasiticus. Control of aflatoxin contamination in field corn by decreasing the zinc levels may be feasible, but no methods to decrease zinc levels are currently available. PMID:3729406

  16. Measuring the diffusion coefficient of ganglioside on cell membrane by fluorescence correlation spectroscopy

    NASA Astrophysics Data System (ADS)

    Dong, Shiqing; You, Minghai; Chen, Jianling; Zhou, Jie; Xie, Shusen; Yang, Hongqin

    2017-06-01

    The fluidity of proteins and lipids on cell membrane plays an important role in cell’s physiological functions. Fluorescence correlation spectroscopy (FCS) is an effective technique to detect the rapid dynamic behaviors of proteins and/or lipids in living cells. In this study, we used the rhodamine6G solution to optimize the FCS system. And, cholera toxin B subunit (CT-B) was used to label ganglioside on living Hela cell membranes. The diffusion time and coefficients of ganglioside can be obtained through fitting the autocorrelation curve based on the model of two-dimensional cell membrane. The results showed that the diffusion coefficients of ganglioside distributed within a wide range. It revealed the lateral diffusion of lipids on cell membrane was inhomogeneous, which was due to different microstructures of cytoplasmic membrane. The study provides a helpful method for further studying the dynamic characteristics of proteins and lipids molecules on living cell membrane.

  17. Estimation of Rotary Stability Derivatives at Subsonic and Transonic Speeds

    NASA Technical Reports Server (NTRS)

    Tobak, Murray; Lessing, Henry C.

    1961-01-01

    The first part of this paper pertains to the estimation of subsonic rotary stability derivatives of wings. The unsteady potential flow problem is solved by a superposition of steady flow solutions. Numerical results for the damping coefficients of triangular wings are presented as functions of aspect ratio and Mach number, and are compared with experimental results over the Mach number range 0 to 1. In the second part, experimental results are used. to point out a close correlation between the nonlinear variations with angle of attack of the static pitching-moment curve slope and the damping-in-pitch coefficient. The underlying basis for the correlation is found as a result of an analysis in which the indicial function concept and. the principle of super-position are adapted to apply to the nonlinear problem. The form of the result suggests a method of estimating nonlinear damping coefficients from results of static wind-tunnel measurements.

  18. Outdoor Performance of a Thin-Film Gallium-Arsenide Photovoltaic Module

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silverman, T. J.; Deceglie, M. G.; Marion, B.

    2013-06-01

    We deployed a 855 cm2 thin-film, single-junction gallium arsenide (GaAs) photovoltaic (PV) module outdoors. Due to its fundamentally different cell technology compared to silicon (Si), the module responds differently to outdoor conditions. On average during the test, the GaAs module produced more power when its temperature was higher. We show that its maximum-power temperature coefficient, while actually negative, is several times smaller in magnitude than that of a Si module used for comparison. The positive correlation of power with temperature in GaAs is due to temperature-correlated changes in the incident spectrum. We show that a simple correction based on precipitablemore » water vapor (PWV) brings the photocurrent temperature coefficient into agreement with that measured by other methods and predicted by theory. The low operating temperature and small temperature coefficient of GaAs give it an energy production advantage in warm weather.« less

  19. Establishment and comparison of three novel methods for the determination of the photodynamic therapy agent 2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) in human serum.

    PubMed

    Chen, Lin; Xiao, Qingqing; Zhang, Xian; Yang, Jin

    2016-03-20

    2-[1-Hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) is a second-generation photosensitizer that has been applied in clinical studies of photodynamic therapy for a variety of malignant lesions. Based on the differences in selectivity and labour intensity, three novel methods - fluorescence detection coupled with high performance liquid chromatography (LC-FLD), LC-tandem mass spectrometry (LC-MS/MS) and fluorescence-based microplate reader methods - were developed for the determination of HPPH in human serum, which allowed comparison of fluorescence and MS platform for HPPH quantification. All three methods have been validated and successfully applied to support the clinical pharmacokinetic study of HPPH. The concentrations measured by LC-FLD matched those by LC-MS/MS with a correlation coefficient (r=0.994) and coefficient of determination (r(2)=0.989). Data consistency was also found between the measurements of microplate reader and LC-MS/MS with a correlation coefficient (r=0.999) and coefficient of determination (r(2)=0.998), indicating that fluorescence assay, the low cost alternative with a relatively poorer selectivity, is clearly suitable for the quantification of HPPH. Calibration curves in the methods of LC-FLD and microplate reader were linear (r˃0.998) over the concentration range from 50 to 5000 ng/mL, and linearity was obtained over the concentration range from 5 to 1000 ng/mL in the LC-MS/MS method. Compared with the other two methods, the fluorescence-based microplate reader method with proven high selectivity should be strongly recommended because of obvious advantages such as the lowest labour intensity, the lowest instrument cost, a better sensitivity than LC-FLD and the very rapid determination of large number of samples (24 samples/40 s). Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Detection of biomarkers for Hepatocellular Carcinoma using a hybrid univariate gene selection methods

    PubMed Central

    2012-01-01

    Background Discovering new biomarkers has a great role in improving early diagnosis of Hepatocellular carcinoma (HCC). The experimental determination of biomarkers needs a lot of time and money. This motivates this work to use in-silico prediction of biomarkers to reduce the number of experiments required for detecting new ones. This is achieved by extracting the most representative genes in microarrays of HCC. Results In this work, we provide a method for extracting the differential expressed genes, up regulated ones, that can be considered candidate biomarkers in high throughput microarrays of HCC. We examine the power of several gene selection methods (such as Pearson’s correlation coefficient, Cosine coefficient, Euclidean distance, Mutual information and Entropy with different estimators) in selecting informative genes. A biological interpretation of the highly ranked genes is done using KEGG (Kyoto Encyclopedia of Genes and Genomes) pathways, ENTREZ and DAVID (Database for Annotation, Visualization, and Integrated Discovery) databases. The top ten genes selected using Pearson’s correlation coefficient and Cosine coefficient contained six genes that have been implicated in cancer (often multiple cancers) genesis in previous studies. A fewer number of genes were obtained by the other methods (4 genes using Mutual information, 3genes using Euclidean distance and only one gene using Entropy). A better result was obtained by the utilization of a hybrid approach based on intersecting the highly ranked genes in the output of all investigated methods. This hybrid combination yielded seven genes (2 genes for HCC and 5 genes in different types of cancer) in the top ten genes of the list of intersected genes. Conclusions To strengthen the effectiveness of the univariate selection methods, we propose a hybrid approach by intersecting several of these methods in a cascaded manner. This approach surpasses all of univariate selection methods when used individually according to biological interpretation and the examination of gene expression signal profiles. PMID:22867264

  1. Oxford Knee Score: cross-cultural adaptation and validation of the Turkish version in patients with osteoarthritis of the knee.

    PubMed

    Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Kınıklı, Gizem İrem; Yüksel, İnci; Atilla, Bülent

    2016-01-01

    The Oxford Knee Score (OKS) is a valid, short, self-administered, and site- specific outcome measure specifically developed for patients with knee arthroplasty. This study aimed to cross-culturally adapt and validate the OKS to be used in Turkish-speaking patients with osteoarthritis of the knee. The OKS was translated and culturally adapted according to the guidelines in the literature. Ninety-one patients (mean age: 55.89±7.85 years) with knee osteoarthritis participated in the study. Patients completed the Turkish version of the Oxford Knee Score (OKS-TR), Short-Form 36 Health Survey (SF-36), and Western Ontario and McMaster Universities Index (WOMAC) questionnaires. Internal consistency was tested using Cronbach's α coefficient. Patients completed the OKS-TR questionnaire twice in 7 days to determine the reproducibility. Correlation between the total results of both tests was determined by Spearman's correlation coefficient and intraclass correlation coefficients (ICC). Validity was assessed by calculating Spearman's correlation coefficient between the OKS, WOMAC, and SF-36 scores. Floor and ceiling effects were analyzed. Internal consistency was high (Cronbach's α: 0.90). The reproducibility tested by 2 different methods showed no significant difference (p>0.05). The construct validity analyses showed a significant correlation between the OKS and the other scores (p<0.05). There was no floor or ceiling effect in total OKS score. The OKS-TR is a reliable and valid measure for the self-assessment of pain and function in Turkish-speaking patients with osteoarthritis of the knee.

  2. Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Hua; Ouyang, Luo; Wang, Jing, E-mail: jhma@smu.edu.cn, E-mail: jing.wang@utsouthwestern.edu

    2014-03-15

    Purpose: To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT. Methods: In this study, the authors systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam onboard CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 to 1.6 mAs per projection at threemore » fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT. Results: The analyses of the repeated measurements show that noise correlation coefficients are nonzero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second-order neighbors are 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. At the 2.0 mm resolution level in the axial-plane noise resolution tradeoff analysis, the noise level of the PWLS-Cor reconstruction is 6.3% lower than that of the PWLS-Dia reconstruction. Conclusions: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.« less

  3. The validity and reliability of an iPhone app for measuring vertical jump performance.

    PubMed

    Balsalobre-Fernández, Carlos; Glaister, Mark; Lockey, Richard Anthony

    2015-01-01

    The purpose of this investigation was to analyse the concurrent validity and reliability of an iPhone app (called: My Jump) for measuring vertical jump performance. Twenty recreationally active healthy men (age: 22.1 ± 3.6 years) completed five maximal countermovement jumps, which were evaluated using a force platform (time in the air method) and a specially designed iPhone app. My jump was developed to calculate the jump height from flight time using the high-speed video recording facility on the iPhone 5 s. Jump heights of the 100 jumps measured, for both devices, were compared using the intraclass correlation coefficient, Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation and Bland-Altman plots. There was almost perfect agreement between the force platform and My Jump for the countermovement jump height (intraclass correlation coefficient = 0.997, P < 0.001; Bland-Altman bias = 1.1 ± 0.5 cm, P < 0.001). In comparison with the force platform, My Jump showed good validity for the CMJ height (r = 0.995, P < 0.001). The results of the present study showed that CMJ height can be easily, accurately and reliably evaluated using a specially developed iPhone 5 s app.

  4. Challenge of assessing symptoms in seriously ill intensive care unit patients: can proxy reporters help?

    PubMed

    Puntillo, Kathleen A; Neuhaus, John; Arai, Shoshana; Paul, Steven M; Gropper, Michael A; Cohen, Neal H; Miaskowski, Christine

    2012-10-01

    Determine levels of agreement among intensive care unit patients and their family members, nurses, and physicians (proxies) regarding patients' symptoms and compare levels of mean intensity (i.e., the magnitude of a symptom sensation) and distress (i.e., the degree of emotionality that a symptom engenders) of symptoms among patients and proxy reporters. Prospective study of proxy reporters of symptoms in seriously ill patients. Two intensive care units in a tertiary medical center in the Western United States. Two hundred and forty-five intensive care unit patients, 243 family members, 103 nurses, and 92 physicians. None. On the basis of the magnitude of intraclass correlation coefficients, where coefficients from .35 to .78 are considered to be appropriately robust, correlation coefficients between patients' and family members' ratings met this criterion (≥.35) for intensity in six of ten symptoms. No intensity ratings between patients and nurses had intraclass correlation coefficients >.32. Three symptoms had intensity correlation coefficients of ≥.36 between patients' and physicians' ratings. Correlation coefficients between patients and family members were >.40 for five symptom-distress ratings. No symptoms had distress correlation coefficients of ≥.28 between patients' and nurses' ratings. Two symptoms had symptom-distress correlation coefficients between patients' and physicians' ratings at >.39. Family members, nurses, and physicians reported higher symptom-intensity scores than patients did for 80%, 60%, and 60% of the symptoms, respectively. Family members, nurses, and physicians reported higher symptom-distress scores than patients did for 90%, 70%, and 80% of the symptoms, respectively. Patient-family intraclass correlation coefficients were sufficiently close for us to consider using family members to help assess intensive care unit patients' symptoms. Relatively low intraclass correlation coefficients between intensive care unit clinicians' and patients' symptom ratings indicate that some proxy raters overestimate whereas others underestimate patients' symptoms. Proxy overestimation of patients' symptom scores warrants further study because this may influence decisions about treating patients' symptoms.

  5. Effects of soot absorption coefficient-Planck function correlation on radiative heat transfer in oxygen-enriched propane turbulent diffusion flame

    NASA Astrophysics Data System (ADS)

    Consalvi, J. L.; Nmira, F.

    2016-03-01

    The main objective of this article is to quantify the influence of the soot absorption coefficient-Planck function correlation on radiative loss and flame structure in an oxygen-enhanced propane turbulent diffusion flame. Calculations were run with and without accounting for this correlation by using a standard k-ε model and the steady laminar flamelet model (SLF) coupled to a joint Probability Density Function (PDF) of mixture fraction, enthalpy defect, scalar dissipation rate, and soot quantities. The PDF transport equation is solved by using a Stochastic Eulerian Field (SEF) method. The modeling of soot production is carried out by using a flamelet-based semi-empirical acetylene/benzene soot model. Radiative heat transfer is modeled by using a wide band correlated-k model and turbulent radiation interactions (TRI) are accounted for by using the Optically-Thin Fluctuation Approximation (OTFA). Predicted soot volume fraction, radiant wall heat flux distribution and radiant fraction are in good agreement with the available experimental data. Model results show that soot absorption coefficient and Planck function are negatively correlated in the region of intense soot emission. Neglecting this correlation is found to increase significantly the radiative loss leading to a substantial impact on flame structure in terms of mean and rms values of temperature. In addition mean and rms values of soot volume fraction are found to be less sensitive to the correlation than temperature since soot formation occurs mainly in a region where its influence is low.

  6. Accuracy of contrast-enhanced spectral mammography for estimating residual tumor size after neoadjuvant chemotherapy in patients with breast cancer: a feasibility study.

    PubMed

    Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano

    2017-01-01

    To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent.

  7. A Bayesian estimate of the concordance correlation coefficient with skewed data.

    PubMed

    Feng, Dai; Baumgartner, Richard; Svetnik, Vladimir

    2015-01-01

    Concordance correlation coefficient (CCC) is one of the most popular scaled indices used to evaluate agreement. Most commonly, it is used under the assumption that data is normally distributed. This assumption, however, does not apply to skewed data sets. While methods for the estimation of the CCC of skewed data sets have been introduced and studied, the Bayesian approach and its comparison with the previous methods has been lacking. In this study, we propose a Bayesian method for the estimation of the CCC of skewed data sets and compare it with the best method previously investigated. The proposed method has certain advantages. It tends to outperform the best method studied before when the variation of the data is mainly from the random subject effect instead of error. Furthermore, it allows for greater flexibility in application by enabling incorporation of missing data, confounding covariates, and replications, which was not considered previously. The superiority of this new approach is demonstrated using simulation as well as real-life biomarker data sets used in an electroencephalography clinical study. The implementation of the Bayesian method is accessible through the Comprehensive R Archive Network. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Cavitation in liquid cryogens. 4: Combined correlations for venturi, hydrofoil, ogives, and pumps

    NASA Technical Reports Server (NTRS)

    Hord, J.

    1974-01-01

    The results of a series of experimental and analytical cavitation studies are presented. Cross-correlation is performed of the developed cavity data for a venturi, a hydrofoil and three scaled ogives. The new correlating parameter, MTWO, improves data correlation for these stationary bodies and for pumping equipment. Existing techniques for predicting the cavitating performance of pumping machinery were extended to include variations in flow coefficient, cavitation parameter, and equipment geometry. The new predictive formulations hold promise as a design tool and universal method for correlating pumping machinery performance. Application of these predictive formulas requires prescribed cavitation test data or an independent method of estimating the cavitation parameter for each pump. The latter would permit prediction of performance without testing; potential methods for evaluating the cavitation parameter prior to testing are suggested.

  9. Estimating consumer familiarity with health terminology: a context-based approach.

    PubMed

    Zeng-Treitler, Qing; Goryachev, Sergey; Tse, Tony; Keselman, Alla; Boxwala, Aziz

    2008-01-01

    Effective health communication is often hindered by a "vocabulary gap" between language familiar to consumers and jargon used in medical practice and research. To present health information to consumers in a comprehensible fashion, we need to develop a mechanism to quantify health terms as being more likely or less likely to be understood by typical members of the lay public. Prior research has used approaches including syllable count, easy word list, and frequency count, all of which have significant limitations. In this article, we present a new method that predicts consumer familiarity using contextual information. The method was applied to a large query log data set and validated using results from two previously conducted consumer surveys. We measured the correlation between the survey result and the context-based prediction, syllable count, frequency count, and log normalized frequency count. The correlation coefficient between the context-based prediction and the survey result was 0.773 (p < 0.001), which was higher than the correlation coefficients between the survey result and the syllable count, frequency count, and log normalized frequency count (p < or = 0.012). The context-based approach provides a good alternative to the existing term familiarity assessment methods.

  10. Empirical correlations for axial dispersion coefficient and Peclet number in fixed-bed columns.

    PubMed

    Rastegar, Seyed Omid; Gu, Tingyue

    2017-03-24

    In this work, a new correlation for the axial dispersion coefficient was obtained using experimental data in the literature for axial dispersion in fixed-bed columns packed with particles. The Chung and Wen correlation, the De Ligny correlation are two popular empirical correlations. However, the former lacks the molecular diffusion term and the latter does not consider bed voidage. The new axial dispersion coefficient correlation in this work was based on additional experimental data in the literature by considering both molecular diffusion and bed voidage. It is more comprehensive and accurate. The Peclet number correlation from the new axial dispersion coefficient correlation on the average leads to 12% lower Peclet number values compared to the values from the Chung and Wen correlation, and in many cases much smaller than those from the De Ligny correlation. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Neurometric assessment of intraoperative anesthetic

    DOEpatents

    Kangas, Lars J.; Keller, Paul E.

    1998-01-01

    The present invention is a method and apparatus for collecting EEG data, reducing the EEG data into coefficients, and correlating those coefficients with a depth of unconsciousness or anesthetic depth, and which obtains a bounded first derivative of anesthetic depth to indicate trends. The present invention provides a developed artificial neural network based method capable of continuously analyzing EEG data to discriminate between awake and anesthetized states in an individual and continuously monitoring anesthetic depth trends in real-time. The present invention enables an anesthesiologist to respond immediately to changes in anesthetic depth of the patient during surgery and to administer the correct amount of anesthetic.

  12. Methods for recalibration of mass spectrometry data

    DOEpatents

    Tolmachev, Aleksey V [Richland, WA; Smith, Richard D [Richland, WA

    2009-03-03

    Disclosed are methods for recalibrating mass spectrometry data that provide improvement in both mass accuracy and precision by adjusting for experimental variance in parameters that have a substantial impact on mass measurement accuracy. Optimal coefficients are determined using correlated pairs of mass values compiled by matching sets of measured and putative mass values that minimize overall effective mass error and mass error spread. Coefficients are subsequently used to correct mass values for peaks detected in the measured dataset, providing recalibration thereof. Sub-ppm mass measurement accuracy has been demonstrated on a complex fungal proteome after recalibration, providing improved confidence for peptide identifications.

  13. REVIEWS OF TOPICAL PROBLEMS: Particle kinetics in highly turbulent plasmas (renormalization and self-consistent field methods)

    NASA Astrophysics Data System (ADS)

    Bykov, Andrei M.; Toptygin, Igor'N.

    1993-11-01

    This review presents methods available for calculating transport coefficients for impurity particles in plasmas with strong long-wave MHD-type velocity and magnetic-field fluctuations, and random ensembles of strong shock fronts. The renormalization of the coefficients of the mean-field equation of turbulent dynamo theory is also considered. Particular attention is devoted to the renormalization method developed by the authors in which the renormalized transport coefficients are calculated from a nonlinear transcendental equation (or a set of such equations) and are expressed in the form of explicit functions of pair correlation tensors describing turbulence. Numerical calculations are reproduced for different turbulence spectra. Spatial transport in a magnetic field and particle acceleration by strong turbulence are investigated. The theory can be used in a wide range of practical problems in plasma physics, atmospheric physics, ocean physics, astrophysics, cosmic-ray physics, and so on.

  14. Serum Liver Fibrosis Markers in the Prognosis of Liver Cirrhosis: A Prospective Observational Study.

    PubMed

    Qi, Xingshun; Liu, Xu; Zhang, Yongguo; Hou, Yue; Ren, Linan; Wu, Chunyan; Chen, Jiang; Xia, Chunlian; Zhao, Jiajun; Wang, Di; Zhang, Yanlin; Zhang, Xia; Lin, Hao; Wang, Hezhi; Wang, Jinling; Cui, Zhongmin; Li, Xueyan; Deng, Han; Hou, Feifei; Peng, Ying; Wang, Xueying; Shao, Xiaodong; Li, Hongyu; Guo, Xiaozhong

    2016-08-02

    BACKGROUND The prognostic role of serum liver fibrosis markers in cirrhotic patients remains unclear. We performed a prospective observational study to evaluate the effect of amino-terminal pro-peptide of type III pro-collagen (PIIINP), collagen IV (CIV), laminin (LN), and hyaluronic acid (HA) on the prognosis of liver cirrhosis. MATERIAL AND METHODS All patients who were diagnosed with liver cirrhosis and admitted to our department were prospectively enrolled. PIIINP, CIV, LN, and HA levels were tested. RESULTS Overall, 108 cirrhotic patients were included. Correlation analysis demonstrated that CIV (coefficient r: 0.658, p<0.001; coefficient r: 0.368, p<0.001), LN (coefficient r: 0.450, p<0.001; coefficient r: 0.343, p<0.001), and HA (coefficient r: 0.325, p=0.001; coefficient r: 0.282, p=0.004) levels, but not PIIINP level (coefficient r: 0.081, p=0.414; coefficient r: 0.090, p=0.363), significantly correlated with Child-Pugh and MELD scores. Logistic regression analysis demonstrated that HA (odds ratio=1.00003, 95% confidence interval [CI]=1.000004-1.000056, p=0.022) was significantly associated with the 6-month mortality. Receiver operating characteristics analysis demonstrated that the area under the curve (AUC) of HA for predicting the 6-month mortality was 0.612 (95%CI=0.508-0.709, p=0.1531). CONCLUSIONS CIV, LN, and HA levels were significantly associated with the severity of liver dysfunction, but might be inappropriate for the prognostic assessment of liver cirrhosis.

  15. [Comparison of two methods for rapid determination of C-reactive protein with the Tina-quant].

    PubMed

    Oremek, G M; Luksaite, R; Bretschneider, I

    2008-03-01

    C-reactive protein (CRP) as an acute phase protein is an important diagnostic marker for the presence and course of human processes. Out of the acute phase proteins it is one of those the concentrations increase most rapidly with its sensitivity being superior to other markers of inflammation, such as leukocytosis, erythrocytic sedimentation rate, and fever. This study compared two-point-of-care assays with the standard laboratory method Tina-quant CRP processed on a Hitachi 917: the immunofiltration assay NycoCard CRP Whole Blood and the turbidimetric immunoassay Micros CRP. Both methods are carried in the presence of a patient, by using capillary or venous blood. Seventy-eight blood samples were analyzed first in the standard laboratory routine and then by both rapid test assays. The precision of both assays was determined from the confidence interval. The results were statistically analyzed by arithmetic standard deviation mean method, variation coefficient, Spearman correlation index, Wilcoxon and Bland-Altman tests, and Passing-Bablock regression. NycoCard CRP Whole Blood showed a correlation coefficient of R = 0.9838; the precision had a coefficient of variation of CV = 1.8759% while As compared with Tina-quant CRP had R = 0.9934 and CV = 0.9160%. Both assays indicated the same results as Tina-quant CRP. Both Tina-quant CRP and NycoCard CRP Whole Blood give the best fit for the rapid determination of CRP.

  16. Manure sampling procedures and nutrient estimation by the hydrometer method for gestation pigs.

    PubMed

    Zhu, Jun; Ndegwa, Pius M; Zhang, Zhijian

    2004-05-01

    Three manure agitation procedures were examined in this study (vertical mixing, horizontal mixing, and no mixing) to determine the efficacy of producing a representative manure sample. The total solids content for manure from gestation pigs was found to be well correlated with the total nitrogen (TN) and total phosphorus (TP) concentrations in the manure, with highly significant correlation coefficients of 0.988 and 0.994, respectively. Linear correlations were observed between the TN and TP contents and the manure specific gravity (correlation coefficients: 0.991 and 0.987, respectively). Therefore, it may be inferred that the nutrients in pig manure can be estimated with reasonable accuracy by measuring the liquid manure specific gravity. A rapid testing method for manure nutrient contents (TN and TP) using a soil hydrometer was also evaluated. The results showed that the estimating error increased from +/-10% to +/-30% with the decrease in TN (from 1000 to 100 ppm) and TP (from 700 to 50 ppm) concentrations in the manure. Data also showed that the hydrometer readings had to be taken within 10 s after mixing to avoid reading drift in specific gravity due to the settling of manure solids.

  17. Structural features that predict real-value fluctuations of globular proteins.

    PubMed

    Jamroz, Michal; Kolinski, Andrzej; Kihara, Daisuke

    2012-05-01

    It is crucial to consider dynamics for understanding the biological function of proteins. We used a large number of molecular dynamics (MD) trajectories of nonhomologous proteins as references and examined static structural features of proteins that are most relevant to fluctuations. We examined correlation of individual structural features with fluctuations and further investigated effective combinations of features for predicting the real value of residue fluctuations using the support vector regression (SVR). It was found that some structural features have higher correlation than crystallographic B-factors with fluctuations observed in MD trajectories. Moreover, SVR that uses combinations of static structural features showed accurate prediction of fluctuations with an average Pearson's correlation coefficient of 0.669 and a root mean square error of 1.04 Å. This correlation coefficient is higher than the one observed in predictions by the Gaussian network model (GNM). An advantage of the developed method over the GNMs is that the former predicts the real value of fluctuation. The results help improve our understanding of relationships between protein structure and fluctuation. Furthermore, the developed method provides a convienient practial way to predict fluctuations of proteins using easily computed static structural features of proteins. Copyright © 2012 Wiley Periodicals, Inc.

  18. Structural features that predict real-value fluctuations of globular proteins

    PubMed Central

    Jamroz, Michal; Kolinski, Andrzej; Kihara, Daisuke

    2012-01-01

    It is crucial to consider dynamics for understanding the biological function of proteins. We used a large number of molecular dynamics trajectories of non-homologous proteins as references and examined static structural features of proteins that are most relevant to fluctuations. We examined correlation of individual structural features with fluctuations and further investigated effective combinations of features for predicting the real-value of residue fluctuations using the support vector regression. It was found that some structural features have higher correlation than crystallographic B-factors with fluctuations observed in molecular dynamics trajectories. Moreover, support vector regression that uses combinations of static structural features showed accurate prediction of fluctuations with an average Pearson’s correlation coefficient of 0.669 and a root mean square error of 1.04 Å. This correlation coefficient is higher than the one observed for the prediction by the Gaussian network model. An advantage of the developed method over the Gaussian network models is that the former predicts the real-value of fluctuation. The results help improve our understanding of relationships between protein structure and fluctuation. Furthermore, the developed method provides a convienient practial way to predict fluctuations of proteins using easily computed static structural features of proteins. PMID:22328193

  19. Mental Task Classification Scheme Utilizing Correlation Coefficient Extracted from Interchannel Intrinsic Mode Function.

    PubMed

    Rahman, Md Mostafizur; Fattah, Shaikh Anowarul

    2017-01-01

    In view of recent increase of brain computer interface (BCI) based applications, the importance of efficient classification of various mental tasks has increased prodigiously nowadays. In order to obtain effective classification, efficient feature extraction scheme is necessary, for which, in the proposed method, the interchannel relationship among electroencephalogram (EEG) data is utilized. It is expected that the correlation obtained from different combination of channels will be different for different mental tasks, which can be exploited to extract distinctive feature. The empirical mode decomposition (EMD) technique is employed on a test EEG signal obtained from a channel, which provides a number of intrinsic mode functions (IMFs), and correlation coefficient is extracted from interchannel IMF data. Simultaneously, different statistical features are also obtained from each IMF. Finally, the feature matrix is formed utilizing interchannel correlation features and intrachannel statistical features of the selected IMFs of EEG signal. Different kernels of the support vector machine (SVM) classifier are used to carry out the classification task. An EEG dataset containing ten different combinations of five different mental tasks is utilized to demonstrate the classification performance and a very high level of accuracy is achieved by the proposed scheme compared to existing methods.

  20. Triple collocation-based estimation of spatially correlated observation error covariance in remote sensing soil moisture data assimilation

    NASA Astrophysics Data System (ADS)

    Wu, Kai; Shu, Hong; Nie, Lei; Jiao, Zhenhang

    2018-01-01

    Spatially correlated errors are typically ignored in data assimilation, thus degenerating the observation error covariance R to a diagonal matrix. We argue that a nondiagonal R carries more observation information making assimilation results more accurate. A method, denoted TC_Cov, was proposed for soil moisture data assimilation to estimate spatially correlated observation error covariance based on triple collocation (TC). Assimilation experiments were carried out to test the performance of TC_Cov. AMSR-E soil moisture was assimilated with a diagonal R matrix computed using the TC and assimilated using a nondiagonal R matrix, as estimated by proposed TC_Cov. The ensemble Kalman filter was considered as the assimilation method. Our assimilation results were validated against climate change initiative data and ground-based soil moisture measurements using the Pearson correlation coefficient and unbiased root mean square difference metrics. These experiments confirmed that deterioration of diagonal R assimilation results occurred when model simulation is more accurate than observation data. Furthermore, nondiagonal R achieved higher correlation coefficient and lower ubRMSD values over diagonal R in experiments and demonstrated the effectiveness of TC_Cov to estimate richly structuralized R in data assimilation. In sum, compared with diagonal R, nondiagonal R may relieve the detrimental effects of assimilation when simulated model results outperform observation data.

  1. A Culture-Specific Nutrient Intake Assessment Instrument in Patients with Pulmonary Tuberculosis

    PubMed Central

    Frediani, Jennifer K.; Tukvadze, Nestani; Sanikidze, Ekaterina; Kipiani, Maia; Hebbar, Gautam; Easley, Kirk A.; Shenvi, Neeta; Ramakrishnan, Usha; Tangpricha, Vin; Blumberg, Henry M.; Ziegler, Thomas R.

    2013-01-01

    Background and Aim To develop and evaluate a culture-specific nutrient intake assessment tool for use in adults with pulmonary tuberculosis (TB) in Tbilisi, Georgia. Methods We developed an instrument to measure food intake over 3 consecutive days using a questionnaire format. The tool was then compared to 24 hour food recalls. Food intake data from 31 subjects with TB were analyzed using the Nutrient Database System for Research (NDS-R) dietary analysis program. Paired t-tests, Pearson correlations and intraclass correlation coefficients (ICC) were used to assess the agreement between the two methods of dietary intake for calculated nutrient intakes. Results The Pearson correlation coefficient for mean daily caloric intake between the 2 methods was 0.37 (P = 0.04) with a mean difference of 171 kcals/day (p = 0.34). The ICC was 0.38 (95% CI: 0.03 to 0.64) suggesting the within-patient variability may be larger than between-patient variability. Results for mean daily intake of total fat, total carbohydrate, total protein, retinol, vitamins D and E, thiamine, calcium, sodium, iron, selenium, copper, and zinc between the two assessment methods were also similar. Conclusions This novel nutrient intake assessment tool provided quantitative nutrient intake data from TB patients. These pilot data can inform larger studies in similar populations. PMID:23541173

  2. Experimental research of digital image correlation system in high temperature test

    NASA Astrophysics Data System (ADS)

    Chen, Li; Wang, Yonghong; Dan, Xizuo; Xiao, Ying; Yang, Lianxiang

    2016-01-01

    Digital Image Correlation (DIC) is a full-field technique based on white-light illumination for displacement and strain measurement. But radiation on the specimen surface at high temperature affects the quality of acquired speckle pattern images for traditional DIC measurement. In order to minimize the radiation effect in high temperature measurement, this paper proposes a two-dimensional ultraviolet digital image correlation system (2D UV-DIC) containing UV LED and UV band-pass filter. It is confirmed by experiments that images acquired by this system saturate at higher temperature in comparison with DIC using filtered blue light imaging system. And the UV-DIC remains minimally affected by radiation at the temperature which is nearing the specimen's maximum working temperature (about 1250°C). In addition, considering the heat disturbance that can't be ignored in actual high temperature measurement, this paper also proposes a method using an air controller in combination with image average algorithm, and the method was then used to obtain the thermal expansion coefficient of the Austenitic chromium-nickel stainless steel specimen at different temperatures. By comparing the coefficients with the results calculated by other method, it shows that this comprehensive method has the advantages of strong anti-interference ability and high precision.

  3. DOAS (differential optical absorption spectroscopy) urban pollution measurements

    NASA Astrophysics Data System (ADS)

    Stevens, Robert K.; Vossler, T. L.

    1991-05-01

    During July and August of 1990, a differential optical absorption spectrometer (DOAS) made by OPSIS Inc. was used to measure gaseous air pollutants over three separate open paths in Atlanta, GA. Over path 1 (1099 m) and path 2 (1824 m), ozone (03), sulfur dioxide (SO2) nitrogen dioxide (NO2), nitrous acid (HNO2) formaldehyde (HCHO), benzene, toluene, and o-xylene were measured. Nitric oxide (NO) and ammonia (NH3) were monitored over path 3 (143 m). The data quality and data capture depended on the compound being measured and the path over which it was measured. Data quality criteria for each compound were chosen such that the average relative standard deviation would be less than 25%. Data capture ranged from 43% for o-xylene for path 1 to 95% for ozone for path 2. Benzene, toluene, and o-xylene concentrations measured over path 2, which crossed over an interstate highway, were higher than concentrations measured over path 1, implicating emissions from vehicles on the highway as a significant source of these compounds. Federal Reference Method (FRN) instruments were located near the DOAS light receivers and measurements of 03, NO2, and NO were made concurrently with the DOAS. Correlation coefficients greater than 0.85 were obtained between the DOAS and FRM's; however, there was a difference between the mean values obtained by the two methods for 03 and NO. A gas chromatograph for measuring volatile organic compounds was operated next to the FRN's. Correlation coefficients of about 0.66 were obtained between the DOAS and GC measurements of benzene and o- xylene. However, the correlation coefficient between the DOAS and GC measurements of toluene averaged only 0.15 for the two DOAS measurement paths. The lack of correlation and other factors indicate the possibility of a localized source of toluene near the GC. In general, disagreements between the two measurement methods could be caused by atmospheric inhomogeneities or interferences in the DOAS and other methods.

  4. Condensation heat transfer correlation for water-ethanol vapor mixture flowing through a plate heat exchanger

    NASA Astrophysics Data System (ADS)

    Zhou, Weiqing; Hu, Shenhua; Ma, Xiangrong; Zhou, Feng

    2018-04-01

    Condensation heat transfer coefficient (HTC) as a function of outlet vapor quality was investigated using water-ethanol vapor mixture of different ethanol vapor concentrations (0%, 1%, 2%, 5%, 10%, 20%) under three different system pressures (31 kPa, 47 kPa, 83 kPa). A heat transfer coefficient was developed by applying multiple linear regression method to experimental data, taking into account the dimensionless numbers which represents the Marangoni condensation effects, such as Re, Pr, Ja, Ma and Sh. The developed correlation can predict the condensation performance within a deviation range from -22% to 32%. Taking PHE's characteristic into consideration and bringing in Ma number and Sh number, a new correlation was developed, which showed a much more accurate prediction, within a deviation from -3.2% to 7.9%.

  5. Small Fermi surfaces and strong correlation effects in Dirac materials with holography

    NASA Astrophysics Data System (ADS)

    Seo, Yunseok; Song, Geunho; Park, Chanyong; Sin, Sang-Jin

    2017-10-01

    Recent discovery of transport anomaly in graphene demonstrated that a system known to be weakly interacting may become strongly correlated if system parameter (s) can be tuned such that fermi surface is sufficiently small. We study the strong correlation effects in the transport coefficients of Dirac materials doped with magnetic impurity under the magnetic field using holographic method. The experimental data of magneto-conductivity are well fit by our theory, however, not much data are available for other transports of Dirac material in such regime. Therefore, our results on heat transport, thermo-electric power and Nernst coefficients are left as predictions of holographic theory for generic Dirac materials in the vicinity of charge neutral point with possible surface gap. We give detailed look over each magneto-transport observable and 3Dplots to guide future experiments.

  6. Predicting the level of job satisfaction based on hardiness and its components among nurses with tension headache.

    PubMed

    Mahdavi, A; Nikmanesh, E; AghaeI, M; Kamran, F; Zahra Tavakoli, Z; Khaki Seddigh, F

    2015-01-01

    Nurses are the most significant part of human resources in a sanitary and health system. Job satisfaction results in the enhancement of organizational productivity, employee commitment to the organization and ensuring his/ her physical and mental health. The present research was conducted with the aim of predicting the level of job satisfaction based on hardiness and its components among the nurses with tension headache. The research method was correlational. The population consisted of all the nurses with tension headache who referred to the relevant specialists in Tehran. The sample size consisted of 50 individuals who were chosen by using the convenience sampling method and were measured and investigated by using the research tools of "Job Satisfaction Test" of Davis, Lofkvist and Weiss and "Personal Views Survey" of Kobasa. The data analysis was carried out by using the Pearson Correlation Coefficient and the Regression Analysis. The research findings demonstrated that the correlation coefficient obtained for "hardiness", "job satisfaction" was 0.506, and this coefficient was significant at the 0.01 level. Moreover, it was specified that the sense of commitment and challenge were stronger predictors for job satisfaction of nurses with tension headache among the components of hardiness, and, about 16% of the variance of "job satisfaction" could be explained by the two components (sense of commitment and challenge).

  7. Developing a stroke severity index based on administrative data was feasible using data mining techniques.

    PubMed

    Sung, Sheng-Feng; Hsieh, Cheng-Yang; Kao Yang, Yea-Huei; Lin, Huey-Juan; Chen, Chih-Hung; Chen, Yu-Wei; Hu, Ya-Han

    2015-11-01

    Case-mix adjustment is difficult for stroke outcome studies using administrative data. However, relevant prescription, laboratory, procedure, and service claims might be surrogates for stroke severity. This study proposes a method for developing a stroke severity index (SSI) by using administrative data. We identified 3,577 patients with acute ischemic stroke from a hospital-based registry and analyzed claims data with plenty of features. Stroke severity was measured using the National Institutes of Health Stroke Scale (NIHSS). We used two data mining methods and conventional multiple linear regression (MLR) to develop prediction models, comparing the model performance according to the Pearson correlation coefficient between the SSI and the NIHSS. We validated these models in four independent cohorts by using hospital-based registry data linked to a nationwide administrative database. We identified seven predictive features and developed three models. The k-nearest neighbor model (correlation coefficient, 0.743; 95% confidence interval: 0.737, 0.749) performed slightly better than the MLR model (0.742; 0.736, 0.747), followed by the regression tree model (0.737; 0.731, 0.742). In the validation cohorts, the correlation coefficients were between 0.677 and 0.725 for all three models. The claims-based SSI enables adjusting for disease severity in stroke studies using administrative data. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Optimal sample sizes for the design of reliability studies: power consideration.

    PubMed

    Shieh, Gwowen

    2014-09-01

    Intraclass correlation coefficients are used extensively to measure the reliability or degree of resemblance among group members in multilevel research. This study concerns the problem of the necessary sample size to ensure adequate statistical power for hypothesis tests concerning the intraclass correlation coefficient in the one-way random-effects model. In view of the incomplete and problematic numerical results in the literature, the approximate sample size formula constructed from Fisher's transformation is reevaluated and compared with an exact approach across a wide range of model configurations. These comprehensive examinations showed that the Fisher transformation method is appropriate only under limited circumstances, and therefore it is not recommended as a general method in practice. For advance design planning of reliability studies, the exact sample size procedures are fully described and illustrated for various allocation and cost schemes. Corresponding computer programs are also developed to implement the suggested algorithms.

  9. Laser transit anemometer software development program

    NASA Technical Reports Server (NTRS)

    Abbiss, John B.

    1989-01-01

    Algorithms were developed for the extraction of two components of mean velocity, standard deviation, and the associated correlation coefficient from laser transit anemometry (LTA) data ensembles. The solution method is based on an assumed two-dimensional Gaussian probability density function (PDF) model of the flow field under investigation. The procedure consists of transforming the data ensembles from the data acquisition domain (consisting of time and angle information) to the velocity space domain (consisting of velocity component information). The mean velocity results are obtained from the data ensemble centroid. Through a least squares fitting of the transformed data to an ellipse representing the intersection of a plane with the PDF, the standard deviations and correlation coefficient are obtained. A data set simulation method is presented to test the data reduction process. Results of using the simulation system with a limited test matrix of input values is also given.

  10. Semantic similarity measures in the biomedical domain by leveraging a web search engine.

    PubMed

    Hsieh, Sheau-Ling; Chang, Wen-Yung; Chen, Chi-Huang; Weng, Yung-Ching

    2013-07-01

    Various researches in web related semantic similarity measures have been deployed. However, measuring semantic similarity between two terms remains a challenging task. The traditional ontology-based methodologies have a limitation that both concepts must be resided in the same ontology tree(s). Unfortunately, in practice, the assumption is not always applicable. On the other hand, if the corpus is sufficiently adequate, the corpus-based methodologies can overcome the limitation. Now, the web is a continuous and enormous growth corpus. Therefore, a method of estimating semantic similarity is proposed via exploiting the page counts of two biomedical concepts returned by Google AJAX web search engine. The features are extracted as the co-occurrence patterns of two given terms P and Q, by querying P, Q, as well as P AND Q, and the web search hit counts of the defined lexico-syntactic patterns. These similarity scores of different patterns are evaluated, by adapting support vector machines for classification, to leverage the robustness of semantic similarity measures. Experimental results validating against two datasets: dataset 1 provided by A. Hliaoutakis; dataset 2 provided by T. Pedersen, are presented and discussed. In dataset 1, the proposed approach achieves the best correlation coefficient (0.802) under SNOMED-CT. In dataset 2, the proposed method obtains the best correlation coefficient (SNOMED-CT: 0.705; MeSH: 0.723) with physician scores comparing with measures of other methods. However, the correlation coefficients (SNOMED-CT: 0.496; MeSH: 0.539) with coder scores received opposite outcomes. In conclusion, the semantic similarity findings of the proposed method are close to those of physicians' ratings. Furthermore, the study provides a cornerstone investigation for extracting fully relevant information from digitizing, free-text medical records in the National Taiwan University Hospital database.

  11. Portable Sleep Monitoring for Diagnosing Sleep Apnea in Hospitalized Patients With Heart Failure.

    PubMed

    Aurora, R Nisha; Patil, Susheel P; Punjabi, Naresh M

    2018-04-21

    Sleep apnea is an underdiagnosed condition in patients with heart failure. Efficient identification of sleep apnea is needed, as treatment may improve heart failure-related outcomes. Currently, use of portable sleep monitoring in hospitalized patients and those at risk for central sleep apnea is discouraged. This study examined whether portable sleep monitoring with respiratory polygraphy can accurately diagnose sleep apnea in patients hospitalized with decompensated heart failure. Hospitalized patients with decompensated heart failure underwent concurrent respiratory polygraphy and polysomnography. Both recordings were scored for obstructive and central disordered breathing events in a blinded fashion, using standard criteria, and the apnea-hypopnea index (AHI) was determined. Pearson's correlation coefficients and Bland-Altman plots were used to examine the concordance among the overall, obstructive, and central AHI values derived by respiratory polygraphy and polysomnography. The sample consisted of 53 patients (47% women) with a mean age of 59.0 years. The correlation coefficient for the overall AHI from the two diagnostic methods was 0.94 (95% CI, 0.89-0.96). The average difference in AHI between the two methods was 3.6 events/h. Analyses of the central and obstructive AHI values showed strong concordance between the two methods, with correlation coefficients of 0.98 (95% CI, 0.96-0.99) and 0.91 (95% CI, 0.84-0.95), respectively. Complete agreement in the classification of sleep apnea severity between the two methods was seen in 89% of the sample. Portable sleep monitoring can accurately diagnose sleep apnea in hospitalized patients with heart failure and may promote early initiation of treatment. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  12. Automated cerebral infarct volume measurement in follow-up noncontrast CT scans of patients with acute ischemic stroke.

    PubMed

    Boers, A M; Marquering, H A; Jochem, J J; Besselink, N J; Berkhemer, O A; van der Lugt, A; Beenen, L F; Majoie, C B

    2013-08-01

    Cerebral infarct volume as observed in follow-up CT is an important radiologic outcome measure of the effectiveness of treatment of patients with acute ischemic stroke. However, manual measurement of CIV is time-consuming and operator-dependent. The purpose of this study was to develop and evaluate a robust automated measurement of the CIV. The CIV in early follow-up CT images of 34 consecutive patients with acute ischemic stroke was segmented with an automated intensity-based region-growing algorithm, which includes partial volume effect correction near the skull, midline determination, and ventricle and hemorrhage exclusion. Two observers manually delineated the CIV. Interobserver variability of the manual assessments and the accuracy of the automated method were evaluated by using the Pearson correlation, Bland-Altman analysis, and Dice coefficients. The accuracy was defined as the correlation with the manual assessment as a reference standard. The Pearson correlation for the automated method compared with the reference standard was similar to the manual correlation (R = 0.98). The accuracy of the automated method was excellent with a mean difference of 0.5 mL with limits of agreement of -38.0-39.1 mL, which were more consistent than the interobserver variability of the 2 observers (-40.9-44.1 mL). However, the Dice coefficients were higher for the manual delineation. The automated method showed a strong correlation and accuracy with the manual reference measurement. This approach has the potential to become the standard in assessing the infarct volume as a secondary outcome measure for evaluating the effectiveness of treatment.

  13. Preliminary evidence for good psychometric properties of the Norwegian version of the Brief Problems Monitor (BPM).

    PubMed

    Richter, Jörg

    2015-04-01

    Methods to assess intervention progress and outcome for frequent use are needed. To provide preliminary information about psychometric properties for the Norwegian version of the Brief Problems Monitor. Cronbach's alpha scores and intra-class correlation coefficients as indicators for internal consistency (reliability) and Pearson correlation coefficients between corresponding subscales of the long and short ASEBA form versions as well as multiple regression coefficients to explore the predictive power of the reduced item-set related to the corresponding scale-scores of the long version were calculated in large, representative data sets of Norwegian children and adolescents. Cronbach's alpha scores of the Norwegian version of the BPM subscales varied between 0.67 (attention BPM-youth) and 0.88 (attention BPM-teacher) and between 0.90 (BPM-youth) and 0.96 (BPM-teacher) for its total problem score. Corresponding subscales from the long versions and the BPM as well as the total problems scores were closely correlated with coefficients of high effect size (all r > 0.80). The variance of the items of the BPM explained about three-quarters or more of the variance in the corresponding subscales of the long version. The Norwegian BPM has good psychometric properties in terms of 1) being acceptable to good internal consistency and in terms of 2) regression coefficients of high effect size from the BPM items to the problem-scale scores of the long versions as validity indicators. Its use in clinical practice and research can be recommended.

  14. Reliability and validity of quantifying absolute muscle hardness using ultrasound elastography.

    PubMed

    Chino, Kentaro; Akagi, Ryota; Dohi, Michiko; Fukashiro, Senshi; Takahashi, Hideyuki

    2012-01-01

    Muscle hardness is a mechanical property that represents transverse muscle stiffness. A quantitative method that uses ultrasound elastography for quantifying absolute human muscle hardness has been previously devised; however, its reliability and validity have not been completely verified. This study aimed to verify the reliability and validity of this quantitative method. The Young's moduli of seven tissue-mimicking materials (in vitro; Young's modulus range, 20-80 kPa; increments of 10 kPa) and the human medial gastrocnemius muscle (in vivo) were quantified using ultrasound elastography. On the basis of the strain/Young's modulus ratio of two reference materials, one hard and one soft (Young's moduli of 7 and 30 kPa, respectively), the Young's moduli of the tissue-mimicking materials and medial gastrocnemius muscle were calculated. The intra- and inter-investigator reliability of the method was confirmed on the basis of acceptably low coefficient of variations (≤6.9%) and substantially high intraclass correlation coefficients (≥0.77) obtained from all measurements. The correlation coefficient between the Young's moduli of the tissue-mimicking materials obtained using a mechanical method and ultrasound elastography was 0.996, which was equivalent to values previously obtained using magnetic resonance elastography. The Young's moduli of the medial gastrocnemius muscle obtained using ultrasound elastography were within the range of values previously obtained using magnetic resonance elastography. The reliability and validity of the quantitative method for measuring absolute muscle hardness using ultrasound elastography were thus verified.

  15. Reliability and Validity of Quantifying Absolute Muscle Hardness Using Ultrasound Elastography

    PubMed Central

    Chino, Kentaro; Akagi, Ryota; Dohi, Michiko; Fukashiro, Senshi; Takahashi, Hideyuki

    2012-01-01

    Muscle hardness is a mechanical property that represents transverse muscle stiffness. A quantitative method that uses ultrasound elastography for quantifying absolute human muscle hardness has been previously devised; however, its reliability and validity have not been completely verified. This study aimed to verify the reliability and validity of this quantitative method. The Young’s moduli of seven tissue-mimicking materials (in vitro; Young’s modulus range, 20–80 kPa; increments of 10 kPa) and the human medial gastrocnemius muscle (in vivo) were quantified using ultrasound elastography. On the basis of the strain/Young’s modulus ratio of two reference materials, one hard and one soft (Young’s moduli of 7 and 30 kPa, respectively), the Young’s moduli of the tissue-mimicking materials and medial gastrocnemius muscle were calculated. The intra- and inter-investigator reliability of the method was confirmed on the basis of acceptably low coefficient of variations (≤6.9%) and substantially high intraclass correlation coefficients (≥0.77) obtained from all measurements. The correlation coefficient between the Young’s moduli of the tissue-mimicking materials obtained using a mechanical method and ultrasound elastography was 0.996, which was equivalent to values previously obtained using magnetic resonance elastography. The Young’s moduli of the medial gastrocnemius muscle obtained using ultrasound elastography were within the range of values previously obtained using magnetic resonance elastography. The reliability and validity of the quantitative method for measuring absolute muscle hardness using ultrasound elastography were thus verified. PMID:23029231

  16. A Novel Method for Measuring the Diffusion, Partition and Convective Mass Transfer Coefficients of Formaldehyde and VOC in Building Materials

    PubMed Central

    Xiong, Jianyin; Huang, Shaodan; Zhang, Yinping

    2012-01-01

    The diffusion coefficient (D m) and material/air partition coefficient (K) are two key parameters characterizing the formaldehyde and volatile organic compounds (VOC) sorption behavior in building materials. By virtue of the sorption process in airtight chamber, this paper proposes a novel method to measure the two key parameters, as well as the convective mass transfer coefficient (h m). Compared to traditional methods, it has the following merits: (1) the K, D m and h m can be simultaneously obtained, thus is convenient to use; (2) it is time-saving, just one sorption process in airtight chamber is required; (3) the determination of h m is based on the formaldehyde and VOC concentration data in the test chamber rather than the generally used empirical correlations obtained from the heat and mass transfer analogy, thus is more accurate and can be regarded as a significant improvement. The present method is applied to measure the three parameters by treating the experimental data in the literature, and good results are obtained, which validates the effectiveness of the method. Our new method also provides a potential pathway for measuring h m of semi-volatile organic compounds (SVOC) by using that of VOC. PMID:23145156

  17. Psychometric properties of the Exercise Benefits/Barriers Scale in Mexican elderly women

    PubMed Central

    Enríquez-Reyna, María Cristina; Cruz-Castruita, Rosa María; Ceballos-Gurrola, Oswaldo; García-Cadena, Cirilo Humberto; Hernández-Cortés, Perla Lizeth; Guevara-Valtier, Milton Carlos

    2017-01-01

    ABSTRACT Objective: analyze and assess the psychometric properties of the subscales in the Spanish version of the Exercise Benefits/Barriers Scale in an elderly population in the Northeast of Mexico. Method: methodological study. The sample consisted of 329 elderly associated with one of the five public centers for senior citizens in the metropolitan area of Northeast Mexico. The psychometric properties included the assessment of the Cronbach's alpha coefficient, the Kaiser Meyer Olkin coefficient, the inter-item correlation, exploratory and confirmatory factor analysis. Results: in the principal components analysis, two components were identified based on the 43 items in the scale. The item-total correlation coefficient of the exercise benefits subscale was good. Nevertheless, the coefficient for the exercise barriers subscale revealed inconsistencies. The reliability and validity were acceptable. The confirmatory factor analysis revealed that the elimination of items improved the goodness of fit of the baseline scale, without affecting its validity or reliability. Conclusion: the Exercise Benefits/Barriers subscale presented satisfactory psychometric properties for the Mexican context. A 15-item short version is presented with factorial structure, validity and reliability similar to the complete scale. PMID:28591306

  18. The reliability and validity of a short food frequency questionnaire among 9–11-year olds: a multinational study on three middle-income and high-income countries

    PubMed Central

    Saloheimo, T; González, S A; Erkkola, M; Milauskas, D M; Meisel, J D; Champagne, C M; Tudor-Locke, C; Sarmiento, O; Katzmarzyk, P T; Fogelholm, M

    2015-01-01

    Objective: The main aim of this study was to assess the reliability and validity of a food frequency questionnaire with 23 food groups (I-FFQ) among a sample of 9–11-year-old children from three different countries that differ on economical development and income distribution, and to assess differences between country sites. Furthermore, we assessed factors associated with I-FFQ's performance. Methods: This was an ancillary study of the International Study of Childhood Obesity, Lifestyle and the Environment. Reliability (n=321) and validity (n=282) components of this study had the same participants. Participation rates were 95% and 70%, respectively. Participants completed two I-FFQs with a mean interval of 4.9 weeks to assess reliability. A 3-day pre-coded food diary (PFD) was used as the reference method in the validity analyses. Wilcoxon signed-rank tests, intraclass correlation coefficients and cross-classifications were used to assess the reliability of I-FFQ. Spearman correlation coefficients, percentage difference and cross-classifications were used to assess the validity of I-FFQ. A logistic regression model was used to assess the relation of selected variables with the estimate of validity. Analyses based on information in the PFDs were performed to assess how participants interpreted food groups. Results: Reliability correlation coefficients ranged from 0.37 to 0.78 and gross misclassification for all food groups was <5%. Validity correlation coefficients were below 0.5 for 22/23 food groups, and they differed among country sites. For validity, gross misclassification was <5% for 22/23 food groups. Over- or underestimation did not appear for 19/23 food groups. Logistic regression showed that country of participation and parental education were associated (P⩽0.05) with the validity of I-FFQ. Analyses of children's interpretation of food groups suggested that the meaning of most food groups was understood by the children. Conclusion: I-FFQ is a moderately reliable method and its validity ranged from low to moderate, depending on food group and country site. PMID:27152180

  19. Translation of the Neck Disability Index and validation of the Greek version in a sample of neck pain patients

    PubMed Central

    Trouli, Marianna N; Vernon, Howard T; Kakavelakis, Kyriakos N; Antonopoulou, Maria D; Paganas, Aristofanis N; Lionis, Christos D

    2008-01-01

    Background Neck pain is a highly prevalent condition resulting in major disability. Standard scales for measuring disability in patients with neck pain have a pivotal role in research and clinical settings. The Neck Disability Index (NDI) is a valid and reliable tool, designed to measure disability in activities of daily living due to neck pain. The purpose of our study was the translation and validation of the NDI in a Greek primary care population with neck complaints. Methods The original version of the questionnaire was used. Based on international standards, the translation strategy comprised forward translations, reconciliation, backward translation and pre-testing steps. The validation procedure concerned the exploration of internal consistency (Cronbach alpha), test-retest reliability (Intraclass Correlation Coefficient, Bland and Altman method), construct validity (exploratory factor analysis) and responsiveness (Spearman correlation coefficient, Standard Error of Measurement and Minimal Detectable Change) of the questionnaire. Data quality was also assessed through completeness of data and floor/ceiling effects. Results The translation procedure resulted in the Greek modified version of the NDI. The latter was culturally adapted through the pre-testing phase. The validation procedure raised a large amount of missing data due to low applicability, which were assessed with two methods. Floor or ceiling effects were not observed. Cronbach alpha was calculated as 0.85, which was interpreted as good internal consistency. Intraclass correlation coefficient was found to be 0.93 (95% CI 0.84–0.97), which was considered as very good test-retest reliability. Factor analysis yielded one factor with Eigenvalue 4.48 explaining 44.77% of variance. The Spearman correlation coefficient (0.3; P = 0.02) revealed some relation between the change score in the NDI and Global Rating of Change (GROC). The SEM and MDC were calculated as 0.64 and 1.78 respectively. Conclusion The Greek version of the NDI measures disability in patients with neck pain in a reliable, valid and responsive manner. It is considered a useful tool for research and clinical settings in Greek Primary Health Care. PMID:18647393

  20. Validity of a New Quantitative Evaluation Method that Uses the Depth of the Surface Imprint as an Indicator for Pitting Edema.

    PubMed

    Kogo, Haruki; Murata, Jun; Murata, Shin; Higashi, Toshio

    2017-01-01

    This study examined the validity of a practical evaluation method for pitting edema by comparing it to other methods, including circumference measurements and ultrasound image measurements. Fifty-one patients (102 legs) from a convalescent ward in Maruyama Hospital were recruited for study 1, and 47 patients (94 legs) from a convalescent ward in Morinaga Hospital were recruited for study 2. The relationship between the depth of the surface imprint and circumferential measurements, as well as the relationship between the depth of the surface imprint and the thickness of the subcutaneous soft tissue on an ultrasonogram, were analyzed using a Spearman correlation coefficient by rank. There was no significant relationship between the surface imprint depth and circumferential measurements. However, there was a significant relationship between the depth of the surface imprint and the thickness of the subcutaneous soft tissue as measured on an ultrasonogram (correlation coefficient 0.736). Our findings suggest that our novel evaluation method for pitting edema, based on a measurement of the surface imprint depth, is both valid and useful.

  1. Predicting β-turns and their types using predicted backbone dihedral angles and secondary structures

    PubMed Central

    2010-01-01

    Background β-turns are secondary structure elements usually classified as coil. Their prediction is important, because of their role in protein folding and their frequent occurrence in protein chains. Results We have developed a novel method that predicts β-turns and their types using information from multiple sequence alignments, predicted secondary structures and, for the first time, predicted dihedral angles. Our method uses support vector machines, a supervised classification technique, and is trained and tested on three established datasets of 426, 547 and 823 protein chains. We achieve a Matthews correlation coefficient of up to 0.49, when predicting the location of β-turns, the highest reported value to date. Moreover, the additional dihedral information improves the prediction of β-turn types I, II, IV, VIII and "non-specific", achieving correlation coefficients up to 0.39, 0.33, 0.27, 0.14 and 0.38, respectively. Our results are more accurate than other methods. Conclusions We have created an accurate predictor of β-turns and their types. Our method, called DEBT, is available online at http://comp.chem.nottingham.ac.uk/debt/. PMID:20673368

  2. Predicting beta-turns and their types using predicted backbone dihedral angles and secondary structures.

    PubMed

    Kountouris, Petros; Hirst, Jonathan D

    2010-07-31

    Beta-turns are secondary structure elements usually classified as coil. Their prediction is important, because of their role in protein folding and their frequent occurrence in protein chains. We have developed a novel method that predicts beta-turns and their types using information from multiple sequence alignments, predicted secondary structures and, for the first time, predicted dihedral angles. Our method uses support vector machines, a supervised classification technique, and is trained and tested on three established datasets of 426, 547 and 823 protein chains. We achieve a Matthews correlation coefficient of up to 0.49, when predicting the location of beta-turns, the highest reported value to date. Moreover, the additional dihedral information improves the prediction of beta-turn types I, II, IV, VIII and "non-specific", achieving correlation coefficients up to 0.39, 0.33, 0.27, 0.14 and 0.38, respectively. Our results are more accurate than other methods. We have created an accurate predictor of beta-turns and their types. Our method, called DEBT, is available online at http://comp.chem.nottingham.ac.uk/debt/.

  3. Automated Segmentation of Kidneys from MR Images in Patients with Autosomal Dominant Polycystic Kidney Disease

    PubMed Central

    Kim, Youngwoo; Ge, Yinghui; Tao, Cheng; Zhu, Jianbing; Chapman, Arlene B.; Torres, Vicente E.; Yu, Alan S.L.; Mrug, Michal; Bennett, William M.; Flessner, Michael F.; Landsittel, Doug P.

    2016-01-01

    Background and objectives Our study developed a fully automated method for segmentation and volumetric measurements of kidneys from magnetic resonance images in patients with autosomal dominant polycystic kidney disease and assessed the performance of the automated method with the reference manual segmentation method. Design, setting, participants, & measurements Study patients were selected from the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease. At the enrollment of the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease Study in 2000, patients with autosomal dominant polycystic kidney disease were between 15 and 46 years of age with relatively preserved GFRs. Our fully automated segmentation method was on the basis of a spatial prior probability map of the location of kidneys in abdominal magnetic resonance images and regional mapping with total variation regularization and propagated shape constraints that were formulated into a level set framework. T2–weighted magnetic resonance image sets of 120 kidneys were selected from 60 patients with autosomal dominant polycystic kidney disease and divided into the training and test datasets. The performance of the automated method in reference to the manual method was assessed by means of two metrics: Dice similarity coefficient and intraclass correlation coefficient of segmented kidney volume. The training and test sets were swapped for crossvalidation and reanalyzed. Results Successful segmentation of kidneys was performed with the automated method in all test patients. The segmented kidney volumes ranged from 177.2 to 2634 ml (mean, 885.4±569.7 ml). The mean Dice similarity coefficient ±SD between the automated and manual methods was 0.88±0.08. The mean correlation coefficient between the two segmentation methods for the segmented volume measurements was 0.97 (P<0.001 for each crossvalidation set). The results from the crossvalidation sets were highly comparable. Conclusions We have developed a fully automated method for segmentation of kidneys from abdominal magnetic resonance images in patients with autosomal dominant polycystic kidney disease with varying kidney volumes. The performance of the automated method was in good agreement with that of manual method. PMID:26797708

  4. Automated Segmentation of Kidneys from MR Images in Patients with Autosomal Dominant Polycystic Kidney Disease.

    PubMed

    Kim, Youngwoo; Ge, Yinghui; Tao, Cheng; Zhu, Jianbing; Chapman, Arlene B; Torres, Vicente E; Yu, Alan S L; Mrug, Michal; Bennett, William M; Flessner, Michael F; Landsittel, Doug P; Bae, Kyongtae T

    2016-04-07

    Our study developed a fully automated method for segmentation and volumetric measurements of kidneys from magnetic resonance images in patients with autosomal dominant polycystic kidney disease and assessed the performance of the automated method with the reference manual segmentation method. Study patients were selected from the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease. At the enrollment of the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease Study in 2000, patients with autosomal dominant polycystic kidney disease were between 15 and 46 years of age with relatively preserved GFRs. Our fully automated segmentation method was on the basis of a spatial prior probability map of the location of kidneys in abdominal magnetic resonance images and regional mapping with total variation regularization and propagated shape constraints that were formulated into a level set framework. T2-weighted magnetic resonance image sets of 120 kidneys were selected from 60 patients with autosomal dominant polycystic kidney disease and divided into the training and test datasets. The performance of the automated method in reference to the manual method was assessed by means of two metrics: Dice similarity coefficient and intraclass correlation coefficient of segmented kidney volume. The training and test sets were swapped for crossvalidation and reanalyzed. Successful segmentation of kidneys was performed with the automated method in all test patients. The segmented kidney volumes ranged from 177.2 to 2634 ml (mean, 885.4±569.7 ml). The mean Dice similarity coefficient ±SD between the automated and manual methods was 0.88±0.08. The mean correlation coefficient between the two segmentation methods for the segmented volume measurements was 0.97 (P<0.001 for each crossvalidation set). The results from the crossvalidation sets were highly comparable. We have developed a fully automated method for segmentation of kidneys from abdominal magnetic resonance images in patients with autosomal dominant polycystic kidney disease with varying kidney volumes. The performance of the automated method was in good agreement with that of manual method. Copyright © 2016 by the American Society of Nephrology.

  5. Apparent diffusion coefficient measurement in glioma: Influence of region-of-interest determination methods on apparent diffusion coefficient values, interobserver variability, time efficiency, and diagnostic ability.

    PubMed

    Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong

    2017-03-01

    To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P < 0.05). Mean ADC value of single-round ROI had the highest effect size (0.72) and the greatest areas under the curve (0.872). Three single-slice methods had good to excellent ICCs (0.67-0.89) and the whole-volume method fair to excellent ICCs (0.32-0.96). Minimum ADC values differed significantly between whole-volume and single-round ROI (P = 0.003) and, between whole-volume and five-round ROI (P = 0.001). The whole-volume method took significantly longer than all single-slice methods (all P < 0.001). ADC measurements are influenced by ROI determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn. Reson. Imaging 2017;45:722-730. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Attenuation of the Squared Canonical Correlation Coefficient under Varying Estimates of Score Reliability

    ERIC Educational Resources Information Center

    Wilson, Celia M.

    2010-01-01

    Research pertaining to the distortion of the squared canonical correlation coefficient has traditionally been limited to the effects of sampling error and associated correction formulas. The purpose of this study was to compare the degree of attenuation of the squared canonical correlation coefficient under varying conditions of score reliability.…

  7. Statistical Study of Turbulence: Spectral Functions and Correlation Coefficients

    NASA Technical Reports Server (NTRS)

    Frenkiel, Francois N.

    1958-01-01

    In reading the publications on turbulence of different authors, one often runs the risk of confusing the various correlation coefficients and turbulence spectra. We have made a point of defining, by appropriate concepts, the differences which exist between these functions. Besides, we introduce in the symbols a few new characteristics of turbulence. In the first chapter, we study some relations between the correlation coefficients and the different turbulence spectra. Certain relations are given by means of demonstrations which could be called intuitive rather than mathematical. In this way we demonstrate that the correlation coefficients between the simultaneous turbulent velocities at two points are identical, whether studied in Lagrange's or in Euler's systems. We then consider new spectra of turbulence, obtained by study of the simultaneous velocities along a straight line of given direction. We determine some relations between these spectra and the correlation coefficients. Examining the relation between the spectrum of the turbulence measured at a fixed point and the longitudinal-correlation curve given by G. I. Taylor, we find that this equation is exact only when the coefficient is very small.

  8. Study on Hyperspectral Estimation Model of Total Nitrogen Content in Soil of Shaanxi Province

    NASA Astrophysics Data System (ADS)

    Liu, Jinbao; Dong, Zhenyu; Chen, Xi

    2018-01-01

    The development of hyperspectral remote sensing technology has been widely used in soil nutrient prediction. The soil is the representative soil type in Shaanxi Province. In this study, the soil total nitrogen content in Shaanxi soil was used as the research target, and the soil samples were measured by reflectance spectroscopy using ASD method. Pre-treatment, the first order differential, second order differential and reflectance logarithmic transformation of the reflected spectrum after pre-treatment, and the hyperspectral estimation model is established by using the least squares regression method and the principal component regression method. The results show that the correlation between the reflectance spectrum and the total nitrogen content of the soil is significantly improved. The correlation coefficient between the original reflectance and soil total nitrogen content is in the range of 350 ~ 2500nm. The correlation coefficient of soil total nitrogen content and first deviation of reflectance is more than 0.5 at 142nm, 1963nm, 2204nm and 2307nm, the second deviation has a significant positive correlation at 1114nm, 1470nm, 1967nm, 2372nm and 2402nm, respectively. After the reciprocal logarithmic transformation of the reflectance with the total nitrogen content of the correlation analysis found that the effect is not obvious. Rc2 = 0.7102, RMSEC = 0.0788; Rv2 = 0.8480, RMSEP = 0.0663, which can achieve the rapid prediction of the total nitrogen content in the region. The results show that the principal component regression model is the best.

  9. Association of Health and Food Expenditures Inequality With Health Outcomes: A Case Study on Iranian Rural Households

    PubMed Central

    Naghdi, Seyran; Ghiasvand, Hesam; Shaarbafchi Zadeh, Nasrin; Azami, Saeidreza; Moradi, Tayebeh

    2014-01-01

    Background: Inequality in households’ and individuals' consumption expenditures is one of the most important aspects of health status difference among households and individuals. Objectives: We investigated the impact of some macro-economic factors specially inequality factors on the Iranian rural health status since 1986 through 2012. Patients and Methods: We conducted a longitudinal ecological and analytical study. The average sample size was 14602 households whom Iranian Statistics Center selected by a multi-stages clustering sampling approach. All required data has been collected from Iranian Statistics Centre and Deputy for Curial Affaires of Iranian Ministry of Health. We calculated the Gini coefficients for the rural food and health expenditures, then conducted a transloge autoregressive order one (AR1) to investigate the association between the Iranian rural households' key mortality rates and the food and health expenditure Gini coefficients, time trend, GDP per capita (PPP), and GDP per capita Gini coefficients. Results: The mean of Gini coefficients were 0.137 and 0.21 for the rural food expenditures inequality based on current and constant price, respectively. In addition, the mean of Gini coefficients were 0.26 and 0.31 for the rural health expenditures inequality based on current and constant price, respectively. The time trend, transloged form of Gini coefficients for health expenditures and GDP per capita Gini coefficients presented a significant negative correlation with transloged form of neonatal mortality rate. With regard to the transloged form of under five mortality we observed a significant negative correlation with time trend and transloged form of Gini coefficients for health expenditure and GDP per capita. Finally, there was a significant negative correlation between transloged forms of maternal mortality rate. Conclusions: Iranian policy makers should consider the rural health and food expenditures inequality and try to adopt more effective policies and plans to decrease it. In addition, they should improve the macro-economic factors to improve the rural households' health status. PMID:24829771

  10. Unsupervised parameter optimization for automated retention time alignment of severely shifted gas chromatographic data using the piecework alignment algorithm.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierce, Karisa M.; Wright, Bob W.; Synovec, Robert E.

    2007-02-02

    First, simulated chromatographic separations with declining retention time precision were used to study the performance of the piecewise retention time alignment algorithm and to demonstrate an unsupervised parameter optimization method. The average correlation coefficient between the first chromatogram and every other chromatogram in the data set was used to optimize the alignment parameters. This correlation method does not require a training set, so it is unsupervised and automated. This frees the user from needing to provide class information and makes the alignment algorithm more generally applicable to classifying completely unknown data sets. For a data set of simulated chromatograms wheremore » the average chromatographic peak was shifted past two neighboring peaks between runs, the average correlation coefficient of the raw data was 0.46 ± 0.25. After automated, optimized piecewise alignment, the average correlation coefficient was 0.93 ± 0.02. Additionally, a relative shift metric and principal component analysis (PCA) were used to independently quantify and categorize the alignment performance, respectively. The relative shift metric was defined as four times the standard deviation of a given peak’s retention time in all of the chromatograms, divided by the peak-width-at-base. The raw simulated data sets that were studied contained peaks with average relative shifts ranging between 0.3 and 3.0. Second, a “real” data set of gasoline separations was gathered using three different GC methods to induce severe retention time shifting. In these gasoline separations, retention time precision improved ~8 fold following alignment. Finally, piecewise alignment and the unsupervised correlation optimization method were applied to severely shifted GC separations of reformate distillation fractions. The effect of piecewise alignment on peak heights and peak areas is also reported. Piecewise alignment either did not change the peak height, or caused it to slightly decrease. The average relative difference in peak height after piecewise alignment was –0.20%. Piecewise alignment caused the peak areas to either stay the same, slightly increase, or slightly decrease. The average absolute relative difference in area after piecewise alignment was 0.15%.« less

  11. WE-AB-202-08: Feasibility of Single-Inhalation/Single-Energy Xenon CT for High-Resolution Imaging of Regional Lung Ventilation in Humans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinkham, D; Schueler, E; Diehn, M

    Purpose: To demonstrate the efficacy of a novel functional lung imaging method that utilizes single-inhalation, single-energy xenon CT (Xe-CT) lung ventilation scans, and to compare it against the current clinical standard, ventilation single-photon emission CT (V-SPECT). Methods: In an IRB-approved clinical study, 14 patients undergoing thoracic radiotherapy received two successive single inhalation, single energy (80keV) CT images of the entire lung using 100% oxygen and a 70%/30% xenon-oxygen mixture. A subset of ten patients also received concurrent SPECT ventilation scans. Anatomic reproducibility between the two scans was achieved using a custom video biofeedback apparatus. The CT images were registered tomore » each other by deformable registration, and a calculated difference image served as surrogate xenon ventilation map. Both lungs were partitioned into twelve sectors, and a sector-wise correlation was performed between the xenon and V-SPECT scans. A linear regression model was developed with forced expiratory volume (FEV) as a predictor and the coefficient of variation (CoV) as the outcome. Results: The ventilation comparison for five of the patients had either moderate to strong Pearson correlation coefficients (0.47 to 0.69, p<0.05). Of these, four also had moderate to strong Spearman correlation coefficients (0.46 to 0.80, p<0.03). The patients with the strongest correlation had clear regional ventilation deficits. The patient comparisons with the weakest correlations had more homogeneous ventilation distributions, and those patients also had diminished lung function as assessed by spirometry. Analysis of the relationship between CoV and FEV yielded a non-significant trend toward negative correlation (Pearson coefficient −0.60, p<0.15). Conclusion: Significant correlations were found between the Xe-CT and V-SPECT ventilation imagery. The results from this small cohort of patients indicate that single inhalation, single energy Xe-CT has the potential to quantify regional lung ventilation volumetrically with high resolution using widely accessible radiologic equipment. Bill Loo and Peter Maxim are founders of TibaRay, Inc. Bill Loo is also a board member. Bill Loo and Peter Maxim have received research grants from Varian Medical Systems, Inc. and RaySearch Laboratory.« less

  12. Agreement Analysis: What He Said, She Said Versus You Said.

    PubMed

    Vetter, Thomas R; Schober, Patrick

    2018-06-01

    Correlation and agreement are 2 concepts that are widely applied in the medical literature and clinical practice to assess for the presence and strength of an association. However, because correlation and agreement are conceptually distinct, they require the use of different statistics. Agreement is a concept that is closely related to but fundamentally different from and often confused with correlation. The idea of agreement refers to the notion of reproducibility of clinical evaluations or biomedical measurements. The intraclass correlation coefficient is a commonly applied measure of agreement for continuous data. The intraclass correlation coefficient can be validly applied specifically to assess intrarater reliability and interrater reliability. As its name implies, the Lin concordance correlation coefficient is another measure of agreement or concordance. In undertaking a comparison of a new measurement technique with an established one, it is necessary to determine whether they agree sufficiently for the new to replace the old. Bland and Altman demonstrated that using a correlation coefficient is not appropriate for assessing the interchangeability of 2 such measurement methods. They in turn described an alternative approach, the since widely applied graphical Bland-Altman Plot, which is based on a simple estimation of the mean and standard deviation of differences between measurements by the 2 methods. In reading a medical journal article that includes the interpretation of diagnostic tests and application of diagnostic criteria, attention is conventionally focused on aspects like sensitivity, specificity, predictive values, and likelihood ratios. However, if the clinicians who interpret the test cannot agree on its interpretation and resulting typically dichotomous or binary diagnosis, the test results will be of little practical use. Such agreement between observers (interobserver agreement) about a dichotomous or binary variable is often reported as the kappa statistic. Assessing the interrater agreement between observers, in the case of ordinal variables and data, also has important biomedical applicability. Typically, this situation calls for use of the Cohen weighted kappa. Questionnaires, psychometric scales, and diagnostic tests are widespread and increasingly used by not only researchers but also clinicians in their daily practice. It is essential that these questionnaires, scales, and diagnostic tests have a high degree of agreement between observers. It is therefore vital that biomedical researchers and clinicians apply the appropriate statistical measures of agreement to assess the reproducibility and quality of these measurement instruments and decision-making processes.

  13. The Persian developmental sentence scoring as a clinical measure of morphosyntax in children.

    PubMed

    Jalilevand, Nahid; Kamali, Mohammad; Modarresi, Yahya; Kazemi, Yalda

    2016-01-01

    Background: Developmental Sentence Scoring (DSS) was developed as a numerical measurement and a clinical method based on the morphosyntactic acquisition in the English language. The aim of this study was to develop a new numerical tool similar to DSS to assess the morphosyntactic abilities in Persian-speaking children. Methods: In this cross-sectional and comparative study, the language samples of 115 typically developing Persian-speaking children aged 30 - 65 months were audio recorded during the free play and picture description sessions. The Persian Developmental Sentence Score (PDSS) and the Mean Length of Utterance (MLU) were calculated. Pearson correlation and one - way Analysis of variance (ANOVA) were used for data analysis. Results: The correlation between PDSS and MLU in morphemes (convergent validity) was significant with a correlation coefficient of 0.97 (p< 0.001). The value Cronbach's Alpha (α= 0.79) in the grammatical categories and the split-half coefficient (0.86) indicated acceptable internal consistency reliability. Conclusion: The PDSS could be used as a reliable numerical measurement to estimate the syntactic development in Persian-speaking children.

  14. The Persian developmental sentence scoring as a clinical measure of morphosyntax in children

    PubMed Central

    Jalilevand, Nahid; Kamali, Mohammad; Modarresi, Yahya; Kazemi, Yalda

    2016-01-01

    Background: Developmental Sentence Scoring (DSS) was developed as a numerical measurement and a clinical method based on the morphosyntactic acquisition in the English language. The aim of this study was to develop a new numerical tool similar to DSS to assess the morphosyntactic abilities in Persian-speaking children. Methods: In this cross-sectional and comparative study, the language samples of 115 typically developing Persian-speaking children aged 30 - 65 months were audio recorded during the free play and picture description sessions. The Persian Developmental Sentence Score (PDSS) and the Mean Length of Utterance (MLU) were calculated. Pearson correlation and one – way Analysis of variance (ANOVA) were used for data analysis. Results: The correlation between PDSS and MLU in morphemes (convergent validity) was significant with a correlation coefficient of 0.97 (p< 0.001). The value Cronbach's Alpha (α= 0.79) in the grammatical categories and the split-half coefficient (0.86) indicated acceptable internal consistency reliability. Conclusion: The PDSS could be used as a reliable numerical measurement to estimate the syntactic development in Persian-speaking children. PMID:28210600

  15. [Determination of hydroxyproline in liver tissue by hydrophilic interaction chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry].

    PubMed

    Liu, Wei; Qi, Shenglan; Xu, Ying; Xiao, Zhun; Fu, Yadong; Chen, Jiamei; Yang, Tao; Liu, Ping

    2017-12-08

    A method for the determination of hydroxyproline (Hyp) in liver tissue of mice by hydrophilic interaction chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry (HILIC-HRMS) was developed. The liver tissue samples of normal mice and liver fibrosis mice induced by carbon tetrachloride were hydrolyzed by concentrated hydrochloric acid. After filtrated and diluted by solution, the diluent was separated on an Hypersil GOLD HILIC column (100 mm×2.1 mm, 3 μm). Water-acetonitrile (28:72, v/v)were used as the mobile phases with isocratic elution. Finally, the target analytes were detected in positive model by HRMS equipped with an electrospray ionization source. The linear range of hydroxyproline was from 0.78 to 100.00 μg/L with the correlation coefficient ( R 2 ) of 0.9983. The limit of quantification was 0.78 μg/L. By detecting the spiked samples, the recoveries were in the range of 97.4%-100.9% with the relative standard deviations (RSDs) between 1.4% and 2.0%. In addition, comparison of the measurement results by this method and the chloramine T method was proceeded. It was found that the linear correlation between the two methods was very good, and the Pearson correlation coefficient was 0.927. And this method had simpler operation procedure and higher accuracy than chloramine T method. This method can be used for the quick determination of hydroxyproline in liver tissue samples.

  16. Demonstration and Evaluation of Solid Phase Microextraction for the Assessment of Bioavailability and Contaminant Mobility. ESTCP Cost and Performance Report

    DTIC Science & Technology

    2012-08-01

    subsequent chemical analysis (into acetonitrile for high-performance liquid chromatography [ HPLC ] analysis or hexane for gas chromatography [GC... analysis ) is rapid and complete. In this work, PAHs were analyzed by Waters 2795 HPLC with fluorescent detection (USEPA Method 8310) and PCBs were...detection limits by direct water injection versus SPME with PDMS and coefficient of variation and correlation coefficient for SPME. Analysis by HPLC

  17. A contribution toward rational modeling of the pressure-strain-rate correlation

    NASA Technical Reports Server (NTRS)

    Lee, Moon Joo

    1990-01-01

    A novel method of obtaining an analytical expression of the 'linear part' of the pressure-strain-rate tensor in terms of the anisotropy tensor of the Reynolds stresses has been developed, where the coefficients of the seven independent tensor terms are functions of the invariants of the Reynolds-stress anisotropy. The coefficients are evaluated up to fourth order in the anisotropy of the Reynolds stresses to provide guidance for development of a turbulence model.

  18. Potential energy surface and rate coefficients of protonated cyanogen (HNCCN+) induced by collision with helium (He) at low temperature

    NASA Astrophysics Data System (ADS)

    Bop, Cheikh T.; Faye, N. AB; Hammami, K.

    2018-05-01

    Nitriles have been identified in space. Accurately modeling their abundance requires calculations of collisional rate coefficients. These data are obtained by first computing potential energy surfaces (PES) and cross-sections using high accurate quantum methods. In this paper, we report the first interaction potential of the HNCCN+-He collisional system along with downward rate coefficients among the 11 lowest rotational levels of HNCCN+. The PES was calculated using the explicitly correlated coupled cluster approach with simple, second and non-iterative triple excitation (CCSD(T)-F12) in conjunction with the augmented-correlation consistent-polarized valence triple zeta (aug-cc-pVTZ) Gaussian basis set. It presents two local minima of ˜283 and ˜136 cm-1, the deeper one is located at R = 9 a0 towards the H end (HeṡṡṡHNCCN+). Using the so-computed PES, we calculated rotational cross-sections of HNCCN+ induced by collision with He for energies ranging up to 500 cm-1 with the exact quantum mechanical close coupling (CC) method. Downward rate coefficients were then worked out by thermally averaging the cross-sections at low temperature (T ≤ 100 K). The discussion on propensity rules showed that the odd Δj transitions were favored. The results obtained in this work may be crucially needed to accurately model the abundance of cyanogen and its protonated form in space.

  19. Simultaneous Quantification of Syringic Acid and Kaempferol in Extracts of Bergenia Species Using Validated High-Performance Thin-Layer Chromatographic-Densitometric Method.

    PubMed

    Srivastava, Nishi; Srivastava, Amit; Srivastava, Sharad; Rawat, Ajay Kumar Singh; Khan, Abdul Rahman

    2016-03-01

    A rapid, sensitive, selective and robust quantitative densitometric high-performance thin-layer chromatographic method was developed and validated for separation and quantification of syringic acid (SYA) and kaempferol (KML) in the hydrolyzed extracts of Bergenia ciliata and Bergenia stracheyi. The separation was performed on silica gel 60F254 high-performance thin-layer chromatography plates using toluene : ethyl acetate : formic acid (5 : 4: 1, v/v/v) as the mobile phase. The quantification of SYA and KML was carried out using a densitometric reflection/absorption mode at 290 nm. A dense spot of SYA and KML appeared on the developed plate at a retention factor value of 0.61 ± 0.02 and 0.70 ± 0.01. A precise and accurate quantification was performed using linear regression analysis by plotting the peak area vs concentration 100-600 ng/band (correlation coefficient: r = 0.997, regression coefficient: R(2) = 0.996) for SYA and 100-600 ng/band (correlation coefficient: r = 0.995, regression coefficient: R(2) = 0.991) for KML. The developed method was validated in terms of accuracy, recovery and inter- and intraday study as per International Conference on Harmonisation guidelines. The limit of detection and limit of quantification of SYA and KML were determined, respectively, as 91.63, 142.26 and 277.67, 431.09 ng. The statistical data analysis showed that the method is reproducible and selective for the estimation of SYA and KML in extracts of B. ciliata and B. stracheyi. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Quantifying colocalization by correlation: the Pearson correlation coefficient is superior to the Mander's overlap coefficient.

    PubMed

    Adler, Jeremy; Parmryd, Ingela

    2010-08-01

    The Pearson correlation coefficient (PCC) and the Mander's overlap coefficient (MOC) are used to quantify the degree of colocalization between fluorophores. The MOC was introduced to overcome perceived problems with the PCC. The two coefficients are mathematically similar, differing in the use of either the absolute intensities (MOC) or of the deviation from the mean (PCC). A range of correlated datasets, which extend to the limits of the PCC, only evoked a limited response from the MOC. The PCC is unaffected by changes to the offset while the MOC increases when the offset is positive. Both coefficients are independent of gain. The MOC is a confusing hybrid measurement, that combines correlation with a heavily weighted form of co-occurrence, favors high intensity combinations, downplays combinations in which either or both intensities are low and ignores blank pixels. The PCC only measures correlation. A surprising finding was that the addition of a second uncorrelated population can substantially increase the measured correlation, demonstrating the importance of excluding background pixels. Overall, since the MOC is unresponsive to substantial changes in the data and is hard to interpret, it is neither an alternative to nor a useful substitute for the PCC. The MOC is not suitable for making measurements of colocalization either by correlation or co-occurrence.

  1. Rapid measurement of protein osmotic second virial coefficients by self-interaction chromatography.

    PubMed Central

    Tessier, Peter M; Lenhoff, Abraham M; Sandler, Stanley I

    2002-01-01

    Weak protein interactions are often characterized in terms of the osmotic second virial coefficient (B(22)), which has been shown to correlate with protein phase behavior, such as crystallization. Traditional methods for measuring B(22), such as static light scattering, are too expensive in terms of both time and protein to allow extensive exploration of the effects of solution conditions on B(22). In this work we have measured protein interactions using self-interaction chromatography, in which protein is immobilized on chromatographic particles and the retention of the same protein is measured in isocratic elution. The relative retention of the protein reflects the average protein interactions, which we have related to the second virial coefficient via statistical mechanics. We obtain quantitative agreement between virial coefficients measured by self-interaction chromatography and traditional characterization methods for both lysozyme and chymotrypsinogen over a wide range of pH and ionic strengths, yet self-interaction chromatography requires at least an order of magnitude less time and protein than other methods. The method thus holds significant promise for the characterization of protein interactions requiring only commonly available laboratory equipment, little specialized expertise, and relatively small investments of both time and protein. PMID:11867474

  2. Can Imaging Parameters Provide Information Regarding Histopathology in Head and Neck Squamous Cell Carcinoma? A Meta-Analysis.

    PubMed

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2018-04-01

    Our purpose was to provide data regarding relationships between different imaging and histopathological parameters in HNSCC. MEDLINE library was screened for associations between different imaging parameters and histopathological features in HNSCC up to December 2017. Only papers containing correlation coefficients between different imaging parameters and histopathological findings were acquired for the analysis. Associations between 18 F-FDG positron emission tomography (PET) and KI 67 were reported in 8 studies (236 patients). The pooled correlation coefficient was 0.20 (95% CI = [-0.04; 0.44]). Furthermore, in 4 studies (64 patients), associations between 18 F-fluorothymidine PET and KI 67 were analyzed. The pooled correlation coefficient between SUV max and KI 67 was 0.28 (95% CI = [-0.06; 0.94]). In 2 studies (23 patients), relationships between KI 67 and dynamic contrast-enhanced magnetic resonance imaging were reported. The pooled correlation coefficient between K trans and KI 67 was -0.68 (95% CI = [-0.91; -0.44]). Two studies (31 patients) investigated correlation between apparent diffusion coefficient (ADC) and KI 67. The pooled correlation coefficient was -0.61 (95% CI = [-0.84; -0.38]). In 2 studies (117 patients), relationships between 18 F-FDG PET and p53 were analyzed. The pooled correlation coefficient was 0.0 (95% CI = [-0.87; 0.88]). There were 3 studies (48 patients) that investigated associations between ADC and tumor cell count in HNSCC. The pooled correlation coefficient was -0.53 (95% CI = [-0.74; -0.32]). Associations between 18 F-FDG PET and HIF-1α were investigated in 3 studies (72 patients). The pooled correlation coefficient was 0.44 (95% CI = [-0.20; 1.08]). ADC may predict cell count and proliferation activity, and SUV max may predict expression of HIF-1α in HNSCC. SUV max cannot be used as surrogate marker for expression of KI 67 and p53. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Broadening of polymer chromatographic signals: Analysis, quantification and correction through effective diffusion coefficients.

    PubMed

    Suárez, Inmaculada; Coto, Baudilio

    2015-08-14

    Average molecular weights and polydispersity indexes are some of the most important parameters considered in the polymer characterization. Usually, gel permeation chromatography (GPC) and multi angle light scattering (MALS) are used for this determination, but GPC values are overestimated due to the dispersion introduced by the column separation. Several procedures were proposed to correct such effect usually involving more complex calibration processes. In this work, a new method of calculation has been considered including diffusion effects. An equation for the concentration profile due to diffusion effects along the GPC column was considered to be a Fickian function and polystyrene narrow standards were used to determine effective diffusion coefficients. The molecular weight distribution function of mono and poly disperse polymers was interpreted as a sum of several Fickian functions representing a sample formed by only few kind of polymer chains with specific molecular weight and diffusion coefficient. Proposed model accurately fit the concentration profile along the whole elution time range as checked by the computed standard deviation. Molecular weights obtained by this new method are similar to those obtained by MALS or traditional GPC while polydispersity index values are intermediate between those obtained by the traditional GPC combined to Universal Calibration method and the MALS method. Values for Pearson and Lin coefficients shows improvement in the correlation of polydispersity index values determined by GPC and MALS methods when diffusion coefficients and new methods are used. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Employing the Gini coefficient to measure participation inequality in treatment-focused Digital Health Social Networks.

    PubMed

    van Mierlo, Trevor; Hyatt, Douglas; Ching, Andrew T

    2016-01-01

    Digital Health Social Networks (DHSNs) are common; however, there are few metrics that can be used to identify participation inequality. The objective of this study was to investigate whether the Gini coefficient, an economic measure of statistical dispersion traditionally used to measure income inequality, could be employed to measure DHSN inequality. Quarterly Gini coefficients were derived from four long-standing DHSNs. The combined data set included 625,736 posts that were generated from 15,181 actors over 18,671 days. The range of actors (8-2323), posts (29-28,684), and Gini coefficients (0.15-0.37) varied. Pearson correlations indicated statistically significant associations between number of actors and number of posts (0.527-0.835, p  < .001), and Gini coefficients and number of posts (0.342-0.725, p  < .001). However, the association between Gini coefficient and number of actors was only statistically significant for the addiction networks (0.619 and 0.276, p  < .036). Linear regression models had positive but mixed R 2 results (0.333-0.527). In all four regression models, the association between Gini coefficient and posts was statistically significant ( t  = 3.346-7.381, p  < .002). However, unlike the Pearson correlations, the association between Gini coefficient and number of actors was only statistically significant in the two mental health networks ( t  = -4.305 and -5.934, p  < .000). The Gini coefficient is helpful in measuring shifts in DHSN inequality. However, as a standalone metric, the Gini coefficient does not indicate optimal numbers or ratios of actors to posts, or effective network engagement. Further, mixed-methods research investigating quantitative performance metrics is required.

  5. Clinical Evaluation of positioning verification using digital tomosynthesis (DTS) based on bony anatomy and soft tissues for prostate image-guided radiation therapy (IGRT)

    PubMed Central

    Yoo, Sua; Wu, Q. Jackie; Godfrey, Devon; Yan, Hui; Ren, Lei; Das, Shiva; Lee, William R.; Yin, Fang-Fang

    2008-01-01

    Purpose To evaluate on-board digital tomosynthesis (DTS) for patient positioning in comparison with 2D-radiographs and 3D-CBCT. Methods and Materials A total of 92 image sessions from 9 prostate cancer patients were analyzed. An on-board image set was registered to a corresponding reference image set. Four pairs of image sets were used; DRR vs. on-board orthogonal paired radiograph for the 2D method, coronal-reference-DTS (RDTS) vs. on-board coronal-DTS for the coronal-DTS method, sagittal-RDTS vs. on-board sagittal-DTS for the sagittal-DTS method, and planning CT vs. CBCT for the CBCT method. Registration results were compared. Results The systematic errors in all methods were less than 1 mm/1°. When registering bony anatomy, the mean vector differences were 0.21±0.11 cm between 2D and CBCT, 0.11±0.08 cm between CBCT and coronal-DTS, and 0.14±0.07 cm between CBCT and sagittal-DTS. The correlation of CBCT to DTS was stronger (coefficients=0.92–0.95) than the correlation between 2D and CBCT or DTS (coefficients=0.81–0.83). When registering soft tissue, the mean vector differences were 0.18±0.11 cm between CBCT and coronal-DTS and 0.29±0.17 cm between CBCT and sagittal-DTS. The correlation coefficients of CBCT to sagittal-DTS and to coronal-DTS were 0.84 and 0.92, respectively. Conclusions DTS could provide equivalent results to CBCT when bony anatomy is used as landmarks for prostate IGRT. For soft tissue-based positioning verification, coronal-DTS produced equivalent results to CBCT and sagittal-DTS alone was insufficient. DTS could allow comparable soft tissue-based target localization with faster scanning time and less imaging dose compared to CBCT. PMID:19100923

  6. A KARAOKE System Singing Evaluation Method that More Closely Matches Human Evaluation

    NASA Astrophysics Data System (ADS)

    Takeuchi, Hideyo; Hoguro, Masahiro; Umezaki, Taizo

    KARAOKE is a popular amusement for old and young. Many KARAOKE machines have singing evaluation function. However, it is often said that the scores given by KARAOKE machines do not match human evaluation. In this paper a KARAOKE scoring method strongly correlated with human evaluation is proposed. This paper proposes a way to evaluate songs based on the distance between singing pitch and musical scale, employing a vibrato extraction method based on template matching of spectrum. The results show that correlation coefficients between scores given by the proposed system and human evaluation are -0.76∼-0.89.

  7. [SIMULTANEOUS MEASUREMENT OF INTRAVENTRICULAR AND PARENCHYMAL INTRACRANIAL PRESSURE IN PATIENTS WITH SEVERE TRAUMA BRAIN INJURY].

    PubMed

    Oshorov, A V; Popugaev, K A; Savin, I A; Potapov, A A

    2016-01-01

    "Standard" assessment of ICP by measuring liquor ventricular pressure recently questioned. THE OBJECTIVE OF THE STUDY: Compare the values of ventricular and parenchymal ICP against the closure of open liquor drainage and during active CSF drainage. Examined 7 patients with TBI and intracranial hypertension syndrome, GCS 5.6 ± 1.2 points, 4.2 ± age 33 years. Compared parenchymal and ventricular ICP in three time periods: 1--during closure of ventricular drainage, 2--during of the open drains and drainage at the level of 14-15 mmHg, 3--during the period of active drainage. When comparing two methods of measurement used Bland-Altman method. 1. During time period of the closed drainage correlation coefficient was r = 0.83, p < 0.001. Bland-Altman method: the difference of the two measurements is equal to the minimum and 0.7 mm Hg, the standard deviation of 2.02 mm Hg 2. During time period of the open drainage was reduction of the correlation coefficient to r = 0.46, p < 0.01. Bland-Altman method: an increase in the difference of the two measurements to -0.84 mmHg, standard deviation 2.8 mm Hg 3. During time period of the active drainage of cerebrospinal fluid was marked difference between methods of measurement. Bland-Altman method: the difference was 8.64 mm Hg, and a standard deviation of 2.6 mm Hg. 1. During the closure of the ventricular drainage were good correlation between ventricular and parenchymal ICR 2. During open the liquor drainage correlation between the two methods of measuring the intracranial pressure is reduced. 3. During the active CSF drainage correlation between the two methods of measuring intracranial pressure can be completely lost. Under these conditions, CSF pressure is not correctly reflect the ICP 4. For an accurate and continuous measurement of intracranial pressure on the background of the active CSF drainage should be carried out simultaneous parenchymal ICP measurement.

  8. A novel coefficient for detecting and quantifying asymmetry of California electricity market based on asymmetric detrended cross-correlation analysis.

    PubMed

    Wang, Fang

    2016-06-01

    In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρDXA, contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.

  9. Detecting PM2.5's Correlations between Neighboring Cities Using a Time-Lagged Cross-Correlation Coefficient.

    PubMed

    Wang, Fang; Wang, Lin; Chen, Yuming

    2017-08-31

    In order to investigate the time-dependent cross-correlations of fine particulate (PM2.5) series among neighboring cities in Northern China, in this paper, we propose a new cross-correlation coefficient, the time-lagged q-L dependent height crosscorrelation coefficient (denoted by p q (τ, L)), which incorporates the time-lag factor and the fluctuation amplitude information into the analogous height cross-correlation analysis coefficient. Numerical tests are performed to illustrate that the newly proposed coefficient ρ q (τ, L) can be used to detect cross-correlations between two series with time lags and to identify different range of fluctuations at which two series possess cross-correlations. Applying the new coefficient to analyze the time-dependent cross-correlations of PM2.5 series between Beijing and the three neighboring cities of Tianjin, Zhangjiakou, and Baoding, we find that time lags between the PM2.5 series with larger fluctuations are longer than those between PM2.5 series withsmaller fluctuations. Our analysis also shows that cross-correlations between the PM2.5 series of two neighboring cities are significant and the time lags between two PM2.5 series of neighboring cities are significantly non-zero. These findings providenew scientific support on the view that air pollution in neighboring cities can affect one another not simultaneously but with a time lag.

  10. k-Space Image Correlation Spectroscopy: A Method for Accurate Transport Measurements Independent of Fluorophore Photophysics

    PubMed Central

    Kolin, David L.; Ronis, David; Wiseman, Paul W.

    2006-01-01

    We present the theory and application of reciprocal space image correlation spectroscopy (kICS). This technique measures the number density, diffusion coefficient, and velocity of fluorescently labeled macromolecules in a cell membrane imaged on a confocal, two-photon, or total internal reflection fluorescence microscope. In contrast to r-space correlation techniques, we show kICS can recover accurate dynamics even in the presence of complex fluorophore photobleaching and/or “blinking”. Furthermore, these quantities can be calculated without nonlinear curve fitting, or any knowledge of the beam radius of the exciting laser. The number densities calculated by kICS are less sensitive to spatial inhomogeneity of the fluorophore distribution than densities measured using image correlation spectroscopy. We use simulations as a proof-of-principle to show that number densities and transport coefficients can be extracted using this technique. We present calibration measurements with fluorescent microspheres imaged on a confocal microscope, which recover Stokes-Einstein diffusion coefficients, and flow velocities that agree with single particle tracking measurements. We also show the application of kICS to measurements of the transport dynamics of α5-integrin/enhanced green fluorescent protein constructs in a transfected CHO cell imaged on a total internal reflection fluorescence microscope using charge-coupled device area detection. PMID:16861272

  11. Response time correlations for platinum resistance thermometers

    NASA Technical Reports Server (NTRS)

    Pandey, D. K.; Ash, R. L.; Dillon-Townes, L. A.

    1985-01-01

    The 'plunge method' recommended by ASTM has been used to determine the time constant of 100-ohm platinum resistance thermometers (PRT) considered for use in the National Transonic Facility. It is shown that the response time of ventilated PRT can be correlated with the reciprocal of the heat transfer coefficient in a given field. Universal correlations are established for the 100- and 1000-ohm PRT with uncertainties of 20 and 30 percent, respectively. The correlations are found to be consistent with the uncertainty involved in heat transfer correlations available in the literature and are recommended for use in flowing liquids and gases.

  12. Fully automated contour detection of the ascending aorta in cardiac 2D phase-contrast MRI.

    PubMed

    Codari, Marina; Scarabello, Marco; Secchi, Francesco; Sforza, Chiarella; Baselli, Giuseppe; Sardanelli, Francesco

    2018-04-01

    In this study we proposed a fully automated method for localizing and segmenting the ascending aortic lumen with phase-contrast magnetic resonance imaging (PC-MRI). Twenty-five phase-contrast series were randomly selected out of a large population dataset of patients whose cardiac MRI examination, performed from September 2008 to October 2013, was unremarkable. The local Ethical Committee approved this retrospective study. The ascending aorta was automatically identified on each phase of the cardiac cycle using a priori knowledge of aortic geometry. The frame that maximized the area, eccentricity, and solidity parameters was chosen for unsupervised initialization. Aortic segmentation was performed on each frame using active contouring without edges techniques. The entire algorithm was developed using Matlab R2016b. To validate the proposed method, the manual segmentation performed by a highly experienced operator was used. Dice similarity coefficient, Bland-Altman analysis, and Pearson's correlation coefficient were used as performance metrics. Comparing automated and manual segmentation of the aortic lumen on 714 images, Bland-Altman analysis showed a bias of -6.68mm 2 , a coefficient of repeatability of 91.22mm 2 , a mean area measurement of 581.40mm 2 , and a reproducibility of 85%. Automated and manual segmentation were highly correlated (R=0.98). The Dice similarity coefficient versus the manual reference standard was 94.6±2.1% (mean±standard deviation). A fully automated and robust method for identification and segmentation of ascending aorta on PC-MRI was developed. Its application on patients with a variety of pathologic conditions is advisable. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Predicting missing links via correlation between nodes

    NASA Astrophysics Data System (ADS)

    Liao, Hao; Zeng, An; Zhang, Yi-Cheng

    2015-10-01

    As a fundamental problem in many different fields, link prediction aims to estimate the likelihood of an existing link between two nodes based on the observed information. Since this problem is related to many applications ranging from uncovering missing data to predicting the evolution of networks, link prediction has been intensively investigated recently and many methods have been proposed so far. The essential challenge of link prediction is to estimate the similarity between nodes. Most of the existing methods are based on the common neighbor index and its variants. In this paper, we propose to calculate the similarity between nodes by the Pearson correlation coefficient. This method is found to be very effective when applied to calculate similarity based on high order paths. We finally fuse the correlation-based method with the resource allocation method, and find that the combined method can substantially outperform the existing methods, especially in sparse networks.

  14. Limits of the memory coefficient in measuring correlated bursts

    NASA Astrophysics Data System (ADS)

    Jo, Hang-Hyun; Hiraoka, Takayuki

    2018-03-01

    Temporal inhomogeneities in event sequences of natural and social phenomena have been characterized in terms of interevent times and correlations between interevent times. The inhomogeneities of interevent times have been extensively studied, while the correlations between interevent times, often called correlated bursts, are far from being fully understood. For measuring the correlated bursts, two relevant approaches were suggested, i.e., memory coefficient and burst size distribution. Here a burst size denotes the number of events in a bursty train detected for a given time window. Empirical analyses have revealed that the larger memory coefficient tends to be associated with the heavier tail of the burst size distribution. In particular, empirical findings in human activities appear inconsistent, such that the memory coefficient is close to 0, while burst size distributions follow a power law. In order to comprehend these observations, by assuming the conditional independence between consecutive interevent times, we derive the analytical form of the memory coefficient as a function of parameters describing interevent time and burst size distributions. Our analytical result can explain the general tendency of the larger memory coefficient being associated with the heavier tail of burst size distribution. We also find that the apparently inconsistent observations in human activities are compatible with each other, indicating that the memory coefficient has limits to measure the correlated bursts.

  15. Inequality in Maternal Mortality in Iran: An Ecologic Study

    PubMed Central

    Tajik, Parvin; Nedjat, Saharnaz; Afshar, Nozhat Emami; Changizi, Nasrin; Yazdizadeh, Bahareh; Azemikhah, Arash; Aamrolalaei, Sima; Majdzadeh, Reza

    2012-01-01

    Background: Maternal mortality (MM) is an avoidable death and there is national, international and political commitment to reduce it. The objective of this study is to examine the relation of MM to socioeconomic factors and its inequality in Iran's provinces at an ecologic level. Methods: The overall MM from each province was considered for 3 years from 2004 to 2006. The five independent variables whose relations were studied included the literacy rate among men and women in each province, mean annual household income per capita, Gini coefficients in each province, and Human Development Index (HDI). The correlation of Maternal Mortality Ratio (MMR) to the above five variables was evaluated through Pearson's correlation coefficient (simple and weighted for each province's population) and linear regression – by considering MMR as the dependent variable and the Gini coefficient, HDI, and difference in literacy rate among men and women as the independent variables. Results: The mean MMR in the years 2004–2006 was 24.7 in 100,000 live births. The correlation coefficients between MMR and literacy rate among women, literacy rate among men, the mean annual household income per capita, Gini coefficient and HDI were 0.82, 0.90, –0.61, 0.52 and –0.77, respectively. Based on multivariate regression, MMR was significantly associated with HDI (standardized B=–0.93) and difference in literacy rate among men and women (standardized B=–0.47). However, MMR was not significantly associated with the Gini coefficient. Conclusion: This study shows the association between socioeconomic variables and their inequalities with MMR in Iran's provinces at an ecologic level. In addition to the other direct interventions performed to reduce MM, it seems essential to especially focus on more distal factors influencing MMR. PMID:22347608

  16. Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement.

    PubMed

    Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi

    2015-03-01

    Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Photographs were found to have high reliability coefficient (P > 0.05). The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement.

  17. Correlation Coefficients: Appropriate Use and Interpretation.

    PubMed

    Schober, Patrick; Boer, Christa; Schwarte, Lothar A

    2018-05-01

    Correlation in the broadest sense is a measure of an association between variables. In correlated data, the change in the magnitude of 1 variable is associated with a change in the magnitude of another variable, either in the same (positive correlation) or in the opposite (negative correlation) direction. Most often, the term correlation is used in the context of a linear relationship between 2 continuous variables and expressed as Pearson product-moment correlation. The Pearson correlation coefficient is typically used for jointly normally distributed data (data that follow a bivariate normal distribution). For nonnormally distributed continuous data, for ordinal data, or for data with relevant outliers, a Spearman rank correlation can be used as a measure of a monotonic association. Both correlation coefficients are scaled such that they range from -1 to +1, where 0 indicates that there is no linear or monotonic association, and the relationship gets stronger and ultimately approaches a straight line (Pearson correlation) or a constantly increasing or decreasing curve (Spearman correlation) as the coefficient approaches an absolute value of 1. Hypothesis tests and confidence intervals can be used to address the statistical significance of the results and to estimate the strength of the relationship in the population from which the data were sampled. The aim of this tutorial is to guide researchers and clinicians in the appropriate use and interpretation of correlation coefficients.

  18. New Correlation Methods of Evaporation Heat Transfer in Horizontal Microfine Tubes

    NASA Astrophysics Data System (ADS)

    Makishi, Osamu; Honda, Hiroshi

    A stratified flow model and an annular flow model of evaporation heat transfer in horizontal microfin tubes have been proposed. In the stratified flow model, the contributions of thin film evaporation and nucleate boiling in the groove above a stratified liquid were predicted by a previously reported numerical analysis and a newly developed correlation, respectively. The contributions of nucleate boiling and forced convection in the stratified liquid region were predicted by the new correlation and the Carnavos equation, respectively. In the annular flow model, the contributions of nucleate boiling and forced convection were predicted by the new correlation and the Carnavos equation in which the equivalent Reynolds number was introduced, respectively. A flow pattern transition criterion proposed by Kattan et al. was incorporated to predict the circumferential average heat transfer coefficient in the intermediate region by use of the two models. The predictions of the heat transfer coefficient compared well with available experimental data for ten tubes and four refrigerants.

  19. Atom and receptor based 3D QSAR models for generating new conformations from pyrazolopyrimidine as IL-2 inducible tyrosine kinase inhibitors.

    PubMed

    Ul-Haq, Zaheer; Effendi, Juweria Shahrukh; Ashraf, Sajda; Bkhaitan, Majdi M

    2017-06-01

    In the current study, quantitative three-dimensional structure-activity-relationship (3D-QSAR) method was performed to design a model for new chemical entities by utilizing pyrazolopyrimidines. Their inhibiting activity on receptor IL-2 Itk correlates descriptors based on topology and hydrophobicity. The best model developed by ligand-based (atom-based) approach has correlation-coefficient of r 2 : 0.987 and cross-validated squared correlation-coefficient of q 2 : 0.541 with an external prediction capability of r 2 : 0.944. Whereas the best selected model developed by structured-based (receptor-based) approach has correlation-coefficient of r 2 : 0.987, cross-validated squared correlation-coefficient of q 2 : 0.637 with an external predictive ability of r 2 : 0.941. The statistical parameters prove that structure-based gave a better model to design new chemical scaffolds. The results achieved indicated that hydrophobicity at R 1 location play a vital role in the inhibitory activity and introduction of appropriately bulky and strongly hydrophobic-groups at position 3 of the terminal phenyl-group which is highly significant to enhance the activity. Six new pyrazolopyrimidine derivatives were designed. Docking simulation study was carried out and their inhibitory activity was predicted by the best structure based model with predictive activity of ranging from 8.43 to 8.85 log unit. The interacting residues PHE435, ASP500, LYS391, GLU436, MET438, CYS442, ILE369, VAL377 of PDB 4HCT were studied with respect to type of bonding with the new compounds. This study was aimed to search out more potent inhibitors of IL-2 Itk. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Multi-charge-state molecular dynamics and self-diffusion coefficient in the warm dense matter regime

    NASA Astrophysics Data System (ADS)

    Fu, Yongsheng; Hou, Yong; Kang, Dongdong; Gao, Cheng; Jin, Fengtao; Yuan, Jianmin

    2018-01-01

    We present a multi-ion molecular dynamics (MIMD) simulation and apply it to calculating the self-diffusion coefficients of ions with different charge-states in the warm dense matter (WDM) regime. First, the method is used for the self-consistent calculation of electron structures of different charge-state ions in the ion sphere, with the ion-sphere radii being determined by the plasma density and the ion charges. The ionic fraction is then obtained by solving the Saha equation, taking account of interactions among different charge-state ions in the system, and ion-ion pair potentials are computed using the modified Gordon-Kim method in the framework of temperature-dependent density functional theory on the basis of the electron structures. Finally, MIMD is used to calculate ionic self-diffusion coefficients from the velocity correlation function according to the Green-Kubo relation. A comparison with the results of the average-atom model shows that different statistical processes will influence the ionic diffusion coefficient in the WDM regime.

  1. Aerodynamics of a linear oscillating cascade

    NASA Technical Reports Server (NTRS)

    Buffum, Daniel H.; Fleeter, Sanford

    1990-01-01

    The steady and unsteady aerodynamics of a linear oscillating cascade are investigated using experimental and computational methods. Experiments are performed to quantify the torsion mode oscillating cascade aerodynamics of the NASA Lewis Transonic Oscillating Cascade for subsonic inlet flowfields using two methods: simultaneous oscillation of all the cascaded airfoils at various values of interblade phase angle, and the unsteady aerodynamic influence coefficient technique. Analysis of these data and correlation with classical linearized unsteady aerodynamic analysis predictions indicate that the wind tunnel walls enclosing the cascade have, in some cases, a detrimental effect on the cascade unsteady aerodynamics. An Euler code for oscillating cascade aerodynamics is modified to incorporate improved upstream and downstream boundary conditions and also the unsteady aerodynamic influence coefficient technique. The new boundary conditions are shown to improve the unsteady aerodynamic influence coefficient technique. The new boundary conditions are shown to improve the unsteady aerodynamic predictions of the code, and the computational unsteady aerodynamic influence coefficient technique is shown to be a viable alternative for calculation of oscillating cascade aerodynamics.

  2. Multivariate analysis: A statistical approach for computations

    NASA Astrophysics Data System (ADS)

    Michu, Sachin; Kaushik, Vandana

    2014-10-01

    Multivariate analysis is a type of multivariate statistical approach commonly used in, automotive diagnosis, education evaluating clusters in finance etc and more recently in the health-related professions. The objective of the paper is to provide a detailed exploratory discussion about factor analysis (FA) in image retrieval method and correlation analysis (CA) of network traffic. Image retrieval methods aim to retrieve relevant images from a collected database, based on their content. The problem is made more difficult due to the high dimension of the variable space in which the images are represented. Multivariate correlation analysis proposes an anomaly detection and analysis method based on the correlation coefficient matrix. Anomaly behaviors in the network include the various attacks on the network like DDOs attacks and network scanning.

  3. Diffusion of rhodamine B and bovine serum albumin in fibrin gels seeded with primary endothelial cells.

    PubMed

    Shkilnyy, Andriy; Proulx, Pierre; Sharp, Jamie; Lepage, Martin; Vermette, Patrick

    2012-05-01

    Scaffolds with adequate mass transport properties are needed in many tissue engineering applications. Fibrin is considered a good biological material to fabricate such scaffolds. However, very little is known about mass transport in fibrin. Therefore, a method based on the analysis of fluorescence intensity for measuring the apparent diffusion coefficient of rhodamine B and fluorescein-labelled bovine serum albumin (FITC-BSA) is described. The experiments are performed in fibrin gels with and without human umbilical vein endothelial cells (HUVEC). The apparent diffusion coefficients of rhodamine B and FITC-BSA in fibrin (fibrinogen concentration of 4 mg/mL) with different cell densities are reported. A LIVE/DEAD(®) assay is performed to confirm the viability of HUVEC seeded at high densities. Diffusion coefficients for rhodamine B remain more or less constant up to 5×10(5) cells/mL and correlate well with literature values measured by other methods in water systems. This indicates that the presence of HUVEC in the fibrin gels (up to 5×10(5) cells/mL) has almost no effect on the diffusion coefficients. Higher cell densities (>5×10(5) cells/mL) result in a decrease of the diffusion coefficients. Diffusion coefficients of rhodamine B and FITC-BSA obtained by this method agree with diffusion coefficients in water predicted by the Stokes-Einstein equation. The experimental design used in this study can be applied to measure diffusion coefficients in different types of gels seeded or not with living cells. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Revealing how network structure affects accuracy of link prediction

    NASA Astrophysics Data System (ADS)

    Yang, Jin-Xuan; Zhang, Xiao-Dong

    2017-08-01

    Link prediction plays an important role in network reconstruction and network evolution. The network structure affects the accuracy of link prediction, which is an interesting problem. In this paper we use common neighbors and the Gini coefficient to reveal the relation between them, which can provide a good reference for the choice of a suitable link prediction algorithm according to the network structure. Moreover, the statistical analysis reveals correlation between the common neighbors index, Gini coefficient index and other indices to describe the network structure, such as Laplacian eigenvalues, clustering coefficient, degree heterogeneity, and assortativity of network. Furthermore, a new method to predict missing links is proposed. The experimental results show that the proposed algorithm yields better prediction accuracy and robustness to the network structure than existing currently used methods for a variety of real-world networks.

  5. United3D: a protein model quality assessment program that uses two consensus based methods.

    PubMed

    Terashi, Genki; Oosawa, Makoto; Nakamura, Yuuki; Kanou, Kazuhiko; Takeda-Shitaka, Mayuko

    2012-01-01

    In protein structure prediction, such as template-based modeling and free modeling (ab initio modeling), the step that assesses the quality of protein models is very important. We have developed a model quality assessment (QA) program United3D that uses an optimized clustering method and a simple Cα atom contact-based potential. United3D automatically estimates the quality scores (Qscore) of predicted protein models that are highly correlated with the actual quality (GDT_TS). The performance of United3D was tested in the ninth Critical Assessment of protein Structure Prediction (CASP9) experiment. In CASP9, United3D showed the lowest average loss of GDT_TS (5.3) among the QA methods participated in CASP9. This result indicates that the performance of United3D to identify the high quality models from the models predicted by CASP9 servers on 116 targets was best among the QA methods that were tested in CASP9. United3D also produced high average Pearson correlation coefficients (0.93) and acceptable Kendall rank correlation coefficients (0.68) between the Qscore and GDT_TS. This performance was competitive with the other top ranked QA methods that were tested in CASP9. These results indicate that United3D is a useful tool for selecting high quality models from many candidate model structures provided by various modeling methods. United3D will improve the accuracy of protein structure prediction.

  6. Dental and Chronological Ages as Determinants of Peak Growth Period and Its Relationship with Dental Calcification Stages

    PubMed Central

    Litsas, George; Lucchese, Alessandra

    2016-01-01

    Purpose: To investigate the relationship between dental, chronological, and cervical vertebral maturation growth in the peak growth period, as well as to study the association between the dental calcification phases and the skeletal maturity stages during the same growth period. Methods: Subjects were selected from orthodontic pre-treatment cohorts consisting of 420 subjects where 255 were identified and enrolled into the study, comprising 145 girls and 110 boys. The lateral cephalometric and panoramic radiographs were examined from the archives of the Department of Orthodontics, Aristotle University of Thessaloniki, Greece. Dental age was assessed according to the method of Demirjian, and skeletal maturation according to the Cervical Vertebral Maturation Method. Statistical elaboration included Spearman Brown formula, descriptive statistics, Pearson’s correlation coefficient and regression analysis, paired samples t-test, and Spearman’s rho correlation coefficient. Results: Chronological and dental age showed a high correlation for both gender(r =0.741 for boys, r = 0.770 for girls, p<0.001). The strongest correlation was for the CVM Stage IV for both males (r=0.554) and females (r=0.68). The lowest correlation was for the CVM Stage III in males (r=0.433, p<0.001) and for the CVM Stage II in females (r=0.393, p>0.001). The t-test revealed statistically significant differences between these variables (p<0.001) during the peak period. A statistically significant correlation (p<0.001) between tooth calcification and CVM stages was determined. The second molars showed the highest correlation with CVM stages (CVMS) (r= 0.65 for boys, r = 0.72 for girls). Conclusion: Dental age was more advanced than chronological for both boys and girls for all CVMS. During the peak period these differences were more pronounced. Moreover, all correlations between skeletal and dental stages were statistically significant. The second molars showed the highest correlation whereas the canines showed the lowest correlation for both gender. PMID:27335610

  7. [Development and validation of the Chinese version of modified body imgae scale in Chinese population].

    PubMed

    Gao, X X; Zhu, L; Yu, S J; Xu, T

    2018-02-25

    Objective: To develop the Chinese version of modified body image scale (MBIS) questionnaires, and to validate them in Chinese population. Methods: The original English MBIS questionnaire was translated into Chinese, following the WHO cross-cultural adaptation of health-related quality of life measures. The reliability and validity of the Chinese version of MBIS questionnaires were evaluated in Chinese population, MRKH syndrome patients. Results: Totally 50 patients with MRKH syndrome completed the MBIS and short-form 12-item health survey (SF-12) questionnaires. The Cronbach's alpha of MBIS was 0.741, intraclass correlation coefficients were 0.472-0.815 ( P< 0.01). MBIS scores were positively correlated with SF-12 scores (Spearman correlation coefficient was-0.409, P< 0.01) . Factor analysis showed that MBIS had one common factor. Conclusion: Chinese version of MBIS has high reliability and validity in Chinese population, therefore is suitable for clinic and research.

  8. Serum Liver Fibrosis Markers in the Prognosis of Liver Cirrhosis: A Prospective Observational Study

    PubMed Central

    Qi, Xingshun; Liu, Xu; Zhang, Yongguo; Hou, Yue; Ren, Linan; Wu, Chunyan; Chen, Jiang; Xia, Chunlian; Zhao, Jiajun; Wang, Di; Zhang, Yanlin; Zhang, Xia; Lin, Hao; Wang, Hezhi; Wang, Jinling; Cui, Zhongmin; Li, Xueyan; Deng, Han; Hou, Feifei; Peng, Ying; Wang, Xueying; Shao, Xiaodong; Li, Hongyu; Guo, Xiaozhong

    2016-01-01

    Background The prognostic role of serum liver fibrosis markers in cirrhotic patients remains unclear. We performed a prospective observational study to evaluate the effect of amino-terminal pro-peptide of type III pro-collagen (PIIINP), collagen IV (CIV), laminin (LN), and hyaluronic acid (HA) on the prognosis of liver cirrhosis. Material/Methods All patients who were diagnosed with liver cirrhosis and admitted to our department were prospectively enrolled. PIIINP, CIV, LN, and HA levels were tested. Results Overall, 108 cirrhotic patients were included. Correlation analysis demonstrated that CIV (coefficient r: 0.658, p<0.001; coefficient r: 0.368, p<0.001), LN (coefficient r: 0.450, p<0.001; coefficient r: 0.343, p<0.001), and HA (coefficient r: 0.325, p=0.001; coefficient r: 0.282, p=0.004) levels, but not PIIINP level (coefficient r: 0.081, p=0.414; coefficient r: 0.090, p=0.363), significantly correlated with Child-Pugh and MELD scores. Logistic regression analysis demonstrated that HA (odds ratio=1.00003, 95% confidence interval [CI]=1.000004–1.000056, p=0.022) was significantly associated with the 6-month mortality. Receiver operating characteristics analysis demonstrated that the area under the curve (AUC) of HA for predicting the 6-month mortality was 0.612 (95%CI=0.508–0.709, p=0.1531). Conclusions CIV, LN, and HA levels were significantly associated with the severity of liver dysfunction, but might be inappropriate for the prognostic assessment of liver cirrhosis. PMID:27480906

  9. Validation study of an electronic method of condensed outcomes tools reporting in orthopaedics.

    PubMed

    Farr, Jack; Verma, Nikhil; Cole, Brian J

    2013-12-01

    Patient-reported outcomes (PRO) instruments are a vital source of data for evaluating the efficacy of medical treatments. Historically, outcomes instruments have been designed, validated, and implemented as paper-based questionnaires. The collection of paper-based outcomes information may result in patients becoming fatigued as they respond to redundant questions. This problem is exacerbated when multiple PRO measures are provided to a single patient. In addition, the management and analysis of data collected in paper format involves labor-intensive processes to score and render the data analyzable. Computer-based outcomes systems have the potential to mitigate these problems by reformatting multiple outcomes tools into a single, user-friendly tool.The study aimed to determine whether the electronic outcomes system presented produces results comparable with the test-retest correlations reported for the corresponding orthopedic paper-based outcomes instruments.The study is designed as a crossover study based on consecutive orthopaedic patients arriving at one of two designated orthopedic knee clinics.Patients were assigned to complete either a paper or a computer-administered questionnaire based on a similar set of questions (Knee injury and Osteoarthritis Outcome Score, International Knee Documentation Committee form, 36-Item Short Form survey, version 1, Lysholm Knee Scoring Scale). Each patient completed the same surveys using the other instrument, so that all patients had completed both paper and electronic versions. Correlations between the results from the two modes were studied and compared with test-retest data from the original validation studies.The original validation studies established test-retest reliability by computing correlation coefficients for two administrations of the paper instrument. Those correlation coefficients were all in the range of 0.7 to 0.9, which was deemed satisfactory. The present study computed correlation coefficients between the paper and electronic modes of administration. These correlation coefficients demonstrated similar results with an overall value of 0.86.On the basis of the correlation coefficients, the electronic application of commonly used knee outcome scores compare variably to the traditional paper variants with a high rate of test-retest correlation. This equivalence supports the use of the condensed electronic outcomes system and validates comparison of scores between electronic and paper modes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Calculation of Drug Solubilities by Pharmacy Students.

    ERIC Educational Resources Information Center

    Cates, Lindley A.

    1981-01-01

    A method of estimating the solubilities of drugs in water is reported that is based on a principle applied in quantitative structure-activity relationships. This procedure involves correlation of partition coefficient values using the octanol/water system and aqueous solubility. (Author/MLW)

  11. Neurometric assessment of intraoperative anesthetic

    DOEpatents

    Kangas, L.J.; Keller, P.E.

    1998-07-07

    The present invention is a method and apparatus for collecting EEG data, reducing the EEG data into coefficients, and correlating those coefficients with a depth of unconsciousness or anesthetic depth, and which obtains a bounded first derivative of anesthetic depth to indicate trends. The present invention provides a developed artificial neural network based method capable of continuously analyzing EEG data to discriminate between awake and anesthetized states in an individual and continuously monitoring anesthetic depth trends in real-time. The present invention enables an anesthesiologist to respond immediately to changes in anesthetic depth of the patient during surgery and to administer the correct amount of anesthetic. 7 figs.

  12. Neurometric assessment of intraoperative anesthetic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kangas, L.J.; Keller, P.E.

    1998-07-07

    The present invention is a method and apparatus for collecting EEG data, reducing the EEG data into coefficients, and correlating those coefficients with a depth of unconsciousness or anesthetic depth, and which obtains a bounded first derivative of anesthetic depth to indicate trends. The present invention provides a developed artificial neural network based method capable of continuously analyzing EEG data to discriminate between awake and anesthetized states in an individual and continuously monitoring anesthetic depth trends in real-time. The present invention enables an anesthesiologist to respond immediately to changes in anesthetic depth of the patient during surgery and to administermore » the correct amount of anesthetic. 7 figs.« less

  13. On a numerical method for solving integro-differential equations with variable coefficients with applications in finance

    NASA Astrophysics Data System (ADS)

    Kudryavtsev, O.; Rodochenko, V.

    2018-03-01

    We propose a new general numerical method aimed to solve integro-differential equations with variable coefficients. The problem under consideration arises in finance where in the context of pricing barrier options in a wide class of stochastic volatility models with jumps. To handle the effect of the correlation between the price and the variance, we use a suitable substitution for processes. Then we construct a Markov-chain approximation for the variation process on small time intervals and apply a maturity randomization technique. The result is a system of boundary problems for integro-differential equations with constant coefficients on the line in each vertex of the chain. We solve the arising problems using a numerical Wiener-Hopf factorization method. The approximate formulae for the factors are efficiently implemented by means of the Fast Fourier Transform. Finally, we use a recurrent procedure that moves backwards in time on the variance tree. We demonstrate the convergence of the method using Monte-Carlo simulations and compare our results with the results obtained by the Wiener-Hopf method with closed-form expressions of the factors.

  14. The Outpatient Experience Questionnaire of comprehensive public hospital in China: development, validity and reliability.

    PubMed

    Hu, Yinhuan; Zhang, Zixia; Xie, Jinzhu; Wang, Guanping

    2017-02-01

    The objective of this study is to describe the development of the Outpatient Experience Questionnaire (OPEQ) and to assess the validity and reliability of the scale. Literature review, patient interviews, Delphi method and Cross-sectional validation survey. Six comprehensive public hospitals in China. The survey was carried out on a sample of 600 outpatients. Acceptability of the questionnaire was assessed according to the overall response rate, item non-response rate and the average completion time. Correlation coefficients and confirmatory factor analysis were used to test construct validity. Delphi method was used to assess the content validity of the questionnaire. Cronbach's coefficient alpha and split-half reliability coefficient were used to estimate the internal reliability of the questionnaire. The overall response rate was 97.2% and the item non-response rate ranged from 0% to 0.3%. The mean completion time was 6 min. The Spearman correlations of item-total score ranged from 0.466 to 0.765. The results of confirmatory factor analysis showed that all items had factor loadings above 0.40 and the dimension intercorrelation ranged from 0.449 to 0.773, the goodness of fit of the questionnaire was reasonable. The overall authority grade of expert consultation was 0.80 and Kendall's coefficient of concordance W was 0.186. The Cronbach's coefficients alpha of six dimensions ranged from 0.708 to 0.895, the split-half reliability coefficient (Spearman-Brown coefficient) was 0.969. The OPEQ is a promising instrument covering the most important aspects which influence outpatient experiences of comprehensive public hospital in China. It has good evidence for acceptability, validity and reliability. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  15. LASER BIOLOGY AND MEDICINE: Application of laser fluorimetry for determining the influence of a single amino-acid substitution on the individual photophysical parameters of a fluorescent form of a fluorescent protein mRFP1

    NASA Astrophysics Data System (ADS)

    Banishev, A. A.; Vrzheshch, E. P.; Shirshin, E. A.

    2009-03-01

    Individual photophysical parameters of the chromophore of a fluorescent protein mRFP1 and its two mutants (amino-acid substitution at position 66 - mRFP1/ Q66C and mRFP1/Q66S proteins) are determined. For this purpose, apart from conventional methods of fluorimetry and spectrophotometry, nonlinear laser fluorimetry is used. It is shown that the individual extinction coefficients of the chromophore of proteins correlate (correlation coefficient above 0.9) with the volume of the substituted amino-acid residue at position 66 (similar to the positions of the absorption, fluorescence excitation and emission maxima).

  16. Robust spectral-domain optical coherence tomography speckle model and its cross-correlation coefficient analysis

    PubMed Central

    Liu, Xuan; Ramella-Roman, Jessica C.; Huang, Yong; Guo, Yuan; Kang, Jin U.

    2013-01-01

    In this study, we proposed a generic speckle simulation for optical coherence tomography (OCT) signal, by convolving the point spread function (PSF) of the OCT system with the numerically synthesized random sample field. We validated our model and used the simulation method to study the statistical properties of cross-correlation coefficients (XCC) between Ascans which have been recently applied in transverse motion analysis by our group. The results of simulation show that over sampling is essential for accurate motion tracking; exponential decay of OCT signal leads to an under estimate of motion which can be corrected; lateral heterogeneity of sample leads to an over estimate of motion for a few pixels corresponding to the structural boundary. PMID:23456001

  17. Correlates of anxiety and depression among patients with type 2 diabetes mellitus.

    PubMed

    Balhara, Yatan Pal Singh; Sagar, Rajesh

    2011-07-01

    Research has established the relation between diabetes and depression. Both diabetes and anxiety/depression are independently associated with increased morbidity and mortality. The present study aims at assessing the prevalence of anxiety/depression among outpatients receiving treatment for type 2 diabetes. The study was conducted in the endocrinology outpatient department of an urban tertiary care center. The instruments used included a semi-structured questionnaire, HbA1c levels, fasting blood glucose and postprandial blood glucose, Brief Patient Health Questionnaire, and Hospital Anxiety and Depression Scale (HADS). Analysis was carried out using the SPSS version 16.0. Pearson's correlation coefficient was calculated to find out the correlations. ANOVA was carried out for the in between group comparisons. There was a significant correlation between the HADS-Anxiety scale and Body Mass Index (BMI) with a correlation coefficient of 0.34 (P = 0.008). Also, a significant correlation existed between HADS-Depression scale and BMI (correlation coefficient, 0.36; P = 0.004). Significant correlation were observed between the duration of daily physical exercise and HADS-Anxiety (coefficient of correlation, -0.25; P = 0.04) scores. HADS-Anxiety scores were found to be related to HbA1c levels (correlation-coefficient, 0.41; P = 0.03) and postprandial blood glucose levels (correlation-coefficient, 0.51; P = 0.02). Monitoring of biochemical parameters like HbA1c and postprandial blood glucose levels and BMI could be a guide to development of anxiety in these patients. Also, physical exercise seems to have a protective effect on anxiety in those with type 2 diabetes mellitus.

  18. Variances in solar collector performance predictions due to different methods of evaluating wind heat transfer coefficients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramsey, J.W.; Charmchi, M.

    1980-11-01

    The performance of several solar collector configurations has been predicted using both inappropriate and appropriate relations to evaluate the wind-related heat transfer coefficient. The combinations analyzed are: one or two covers and a selectively absorbing surface coating, and one or two covers and a nonselectively absorbing surface coating all collectors are of the basic liquid heating type. It is shown that the optimum results are obtained by using a global correlation equation proposed by Sparrow et al. (1979).

  19. Mobile detection system to evaluate reactive hyperemia using radionuclide plethysmography.

    PubMed

    Harel, François; Ngo, Quam; Finnerty, Vincent; Hernandez, Edgar; Khairy, Paul; Dupuis, Jocelyn

    2007-08-01

    We validated a novel mobile detection system to evaluate reactive hyperemia using the radionuclide plethysmography technique. Twenty-six subjects underwent simultaneously radionuclide plethysmography with strain gauge plethysmography. Strain gauge and radionuclide methods showed excellent reproducibility with intraclass correlation coefficients of 0.96 and 0.89 respectively. There was also a good correlation of flows between the two methods during reactive hyperemia (r = 0.87). We conclude that radionuclide plethysmography using this mobile detection system is a non-invasive alternative to assess forearm blood flow and its dynamic variations during reactive hyperemia.

  20. Quantitative Mapping of Pore Fraction Variations in Silicon Nitride Using an Ultrasonic Contact Scan Technique

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Kiser, James D.; Swickard, Suzanne M.; Szatmary, Steven A.; Kerwin, David P.

    1993-01-01

    An ultrasonic scan procedure using the pulse-echo contact configuration was employed to obtain maps of pore fraction variations in sintered silicon nitride samples in terms of ultrasonic material properties. Ultrasonic velocity, attenuation coefficient, and reflection coefficient images were obtained simultaneously over a broad band of frequencies (e.g., 30 to 110 MHz) by using spectroscopic analysis. Liquid and membrane (dry) coupling techniques and longitudinal and shear-wave energies were used. The major results include the following: Ultrasonic velocity (longitudinal and shear wave) images revealed and correlated with the extent of average through-thickness pore fraction variations in the silicon nitride disks. Attenuation coefficient images revealed pore fraction nonuniformity due to the scattering that occurred at boundaries between regions of high and low pore fraction. Velocity and attenuation coefficient images were each nearly identical for machined and polished disks, making the method readily applicable to machined materials. Velocity images were similar for wet and membrane coupling. Maps of apparent Poisson's ratio constructed from longitudinal and shear-wave velocities quantified Poisson's ratio variations across a silicon nitride disk. Thermal wave images of a disk indicated transient thermal behavior variations that correlated with observed variations in pore fraction and velocity and attenuation coefficients.

  1. Prediction of friction coefficients for gases

    NASA Technical Reports Server (NTRS)

    Taylor, M. F.

    1969-01-01

    Empirical relations are used for correlating laminar and turbulent friction coefficients for gases, with large variations in the physical properties, flowing through smooth tubes. These relations have been used to correlate friction coefficients for hydrogen, helium, nitrogen, carbon dioxide and air.

  2. QSPR modeling of octanol/water partition coefficient of antineoplastic agents by balance of correlations.

    PubMed

    Toropov, Andrey A; Toropova, Alla P; Raska, Ivan; Benfenati, Emilio

    2010-04-01

    Three different splits into the subtraining set (n = 22), the set of calibration (n = 21), and the test set (n = 12) of 55 antineoplastic agents have been examined. By the correlation balance of SMILES-based optimal descriptors quite satisfactory models for the octanol/water partition coefficient have been obtained on all three splits. The correlation balance is the optimization of a one-variable model with a target function that provides both the maximal values of the correlation coefficient for the subtraining and calibration set and the minimum of the difference between the above-mentioned correlation coefficients. Thus, the calibration set is a preliminary test set. Copyright (c) 2009 Elsevier Masson SAS. All rights reserved.

  3. The Robustness of Designs for Trials with Nested Data against Incorrect Initial Intracluster Correlation Coefficient Estimates

    ERIC Educational Resources Information Center

    Korendijk, Elly J. H.; Moerbeek, Mirjam; Maas, Cora J. M.

    2010-01-01

    In the case of trials with nested data, the optimal allocation of units depends on the budget, the costs, and the intracluster correlation coefficient. In general, the intracluster correlation coefficient is unknown in advance and an initial guess has to be made based on published values or subject matter knowledge. This initial estimate is likely…

  4. Method for measuring radial impurity emission profiles using correlations of line integrated signals

    NASA Astrophysics Data System (ADS)

    Kuldkepp, M.; Brunsell, P. R.; Drake, J.; Menmuir, S.; Rachlew, E.

    2006-04-01

    A method of determining radial impurity emission profiles is outlined. The method uses correlations between line integrated signals and is based on the assumption of cylindrically symmetric fluctuations. Measurements at the reversed field pinch EXTRAP T2R show that emission from impurities expected to be close to the edge is clearly different in raw as well as analyzed data to impurities expected to be more central. Best fitting of experimental data to simulated correlation coefficients yields emission profiles that are remarkably close to emission profiles determined using more conventional techniques. The radial extension of the fluctuations is small enough for the method to be used and bandpass filtered signals indicate that fluctuations below 10kHz are cylindrically symmetric. The novel method is not sensitive to vessel window attenuation or wall reflections and can therefore complement the standard methods in the impurity emission reconstruction procedure.

  5. Anisotropic diffusion of fluorescently labeled ATP in rat cardiomyocytes determined by raster image correlation spectroscopy

    PubMed Central

    Vendelin, Marko; Birkedal, Rikke

    2008-01-01

    A series of experimental data points to the existence of profound diffusion restrictions of ADP/ATP in rat cardiomyocytes. This assumption is required to explain the measurements of kinetics of respiration, sarcoplasmic reticulum loading with calcium, and kinetics of ATP-sensitive potassium channels. To be able to analyze and estimate the role of intracellular diffusion restrictions on bioenergetics, the intracellular diffusion coefficients of metabolites have to be determined. The aim of this work was to develop a practical method for determining diffusion coefficients in anisotropic medium and to estimate the overall diffusion coefficients of fluorescently labeled ATP in rat cardiomyocytes. For that, we have extended raster image correlation spectroscopy (RICS) protocols to be able to discriminate the anisotropy in the diffusion coefficient tensor. Using this extended protocol, we estimated diffusion coefficients of ATP labeled with the fluorescent conjugate Alexa Fluor 647 (Alexa-ATP). In the analysis, we assumed that the diffusion tensor can be described by two values: diffusion coefficient along the myofibril and that across it. The average diffusion coefficients found for Alexa-ATP were as follows: 83 ± 14 μm2/s in the longitudinal and 52 ± 16 μm2/s in the transverse directions (n = 8, mean ± SD). Those values are ∼2 (longitudinal) and ∼3.5 (transverse) times smaller than the diffusion coefficient value estimated for the surrounding solution. Such uneven reduction of average diffusion coefficient leads to anisotropic diffusion in rat cardiomyocytes. Although the source for such anisotropy is uncertain, we speculate that it may be induced by the ordered pattern of intracellular structures in rat cardiomyocytes. PMID:18815224

  6. A systematic review of statistical methods used to test for reliability of medical instruments measuring continuous variables.

    PubMed

    Zaki, Rafdzah; Bulgiba, Awang; Nordin, Noorhaire; Azina Ismail, Noor

    2013-06-01

    Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice. In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. The Intra-class Correlation Coefficient (ICC) is the most popular method with 25 (60%) studies having used this method followed by the comparing means (8 or 19%). Out of 25 studies using the ICC, only 7 (28%) reported the confidence intervals and types of ICC used. Most studies (71%) also tested the agreement of instruments. This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  7. Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement

    PubMed Central

    Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi

    2015-01-01

    Objectives: Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Materials and Methods: Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Results: Photographs were found to have high reliability coefficient (P > 0.05). Conclusion: The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement. PMID:26622272

  8. A novel coefficient for detecting and quantifying asymmetry of California electricity market based on asymmetric detrended cross-correlation analysis

    NASA Astrophysics Data System (ADS)

    Wang, Fang

    2016-06-01

    In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρ D X A , contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.

  9. Evaluation of the Correlation Coefficient of Polyethylene Glycol Treated and Direct Prolactin Results and Comparability with Different Assay System Results.

    PubMed

    Pal, Shyamali

    2017-12-01

    The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.

  10. Settling characteristics of nursery pig manure and nutrient estimation by the hydrometer method.

    PubMed

    Zhu, Jun; Ndegwa, Pius M; Zhang, Zhijian

    2003-05-01

    The hydrometer method to measure manure specific gravity and subsequently relate it to manure nutrient contents was examined in this study. It was found that this method might be improved in estimation accuracy if only manure from a single growth stage of pigs was used (e.g., nursery pig manure used here). The total solids (TS) content of the test manure was well correlated with the total nitrogen (TN) and total phosphorus (TP) concentrations in the manure, with highly significant correlation coefficients of 0.9944 and 0.9873, respectively. Also observed were good linear correlations between the TN and TP contents and the manure specific gravity (correlation coefficients: 0.9836 and 0.9843, respectively). These correlations were much better than those reported by past researchers, in which lumped data for pigs at different growing stages were used. It may therefore be inferred that developing different linear equations for pigs at different ages should improve the accuracy in manure nutrient estimation using a hydrometer. Also, the error of using the hydrometer method to estimate manure TN and TP was found to increase, from +/- 10% to +/- 50%, with the decrease in TN (from 700 ppm to 100 ppm) and TP (from 130 ppm to 30 ppm) concentrations in the manure. The estimation errors for TN and TP may be larger than 50% if the total solids content is below 0.5%. In addition, the rapid settling of solids has long been considered characteristic of swine manure; however, in this study, the solids settling property appeared to be quite poor for nursery pig manure in that no conspicuous settling occurred after the manure was left statically for 5 hours. This information has not been reported elsewhere in the literature and may need further research to verify.

  11. [Nitrogen status diagnosis of rice by using a digital camera].

    PubMed

    Jia, Liang-Liang; Fan, Ming-Sheng; Zhang, Fu-Suo; Chen, Xin-Ping; Lü, Shi-Hua; Sun, Yan-Ming

    2009-08-01

    In the present research, a field experiment with different N application rate was conducted to study the possibility of using visible band color analysis methods to monitor the N status of rice canopy. The Correlations of visible spectrum band color intensity between rice canopy image acquired from a digital camera and conventional nitrogen status diagnosis parameters of leaf SPAD chlorophyll meter readings, total N content, upland biomass and N uptake were studied. The results showed that the red color intensity (R), green color intensity (G) and normalized redness intensity (NRI) have significant inverse linear correlations with the conventional N diagnosis parameters of SPAD readings, total N content, upland biomass and total N uptake. The correlation coefficient values (r) were from -0.561 to -0.714 for red band (R), from -0.452 to -0.505 for green band (G), and from -0.541 to 0.817 for normalized redness intensity (NRI). But the normalized greenness intensity (NGI) showed a significant positive correlation with conventional N parameters and the correlation coefficient values (r) were from 0.505 to 0.559. Compared with SPAD readings, the normalized redness intensity (NRI), with a high r value of 0.541-0.780 with conventional N parameters, could better express the N status of rice. The digital image color analysis method showed the potential of being used in rice N status diagnosis in the future.

  12. Field Air Sampling and Simultaneous Chemical and Sensory Analysis of Livestock Odorants with Sorbent Tube GC-MS/Olfactometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Shicheng; Department of Environmental Science and Engineering, Fudan University, Shanghai 200433; Cai Lingshuang

    2009-05-23

    Characterization and quantification of livestock odorants is one of the most challenging analytical tasks because odor-causing gases are very reactive, polar and often present at very low concentrations in a complex matrix of less important or irrelevant gases. The objective of this research was to develop a novel analytical method for characterization of the livestock odorants including their odor character, odor intensity, and hedonic tone and to apply this method for quantitative analysis of the key odorants responsible for livestock odor. Sorbent tubes packed with Tenax TA were used for field sampling. The automated one-step thermal desorption module coupled withmore » multidimensional gas chromatography-mass spectrometry/olfactometry system was used for simultaneous chemical and odor analysis. Fifteen odorous VOCs and semi-VOCs identified from different livestock species operations were quantified. Method detection limits ranges from 40 pg for skatole to 3590 pg for acetic acid. In addition, odor character, odor intensity and hedonic tone associated with each of the target odorants are also analyzed simultaneously. We found that the mass of each VOCs in the sample correlates well with the log stimulus intensity. All of the correlation coefficients (R{sup 2}) are greater than 0.74, and the top 10 correlation coefficients were greater than 0.90.« less

  13. Development and Psychometric Validation of HIPER-Q to Assess Knowledge of Hypertensive Patients in Cardiac Rehabilitation.

    PubMed

    Santos, Rafaella Zulianello Dos; Bonin, Christiani Decker Batista; Martins, Eliara Ten Caten; Pereira Junior, Moacir; Ghisi, Gabriela Lima de Melo; Macedo, Kassia Rosangela Paz de; Benetti, Magnus

    2018-01-01

    The absence of instruments capable of measuring the level of knowledge of hypertensive patients in cardiac rehabilitation programs about their disease reflects the lack of specific recommendations for these patients. To develop and validate a questionnaire to evaluate the knowledge of hypertensive patients in cardiac rehabilitation programs about their disease. A total of 184 hypertensive patients (mean age 60.5 ± 10 years, 66.8% men) were evaluated. Reproducibility was assessed by calculation of the intraclass correlation coefficient using the test-retest method. Internal consistency was assessed by the Cronbach's alpha and the construct validity by the exploratory factorial analysis. The final version of the instrument had 17 questions organized in areas considered important for patient education. The instrument proposed showed a clarity index of 8.7 (0.25). The intraclass correlation coefficient was 0.804 and the Cronbach's correlation coefficient was 0.648. Factor analysis revealed five factors associated with knowledge areas. Regarding the criterion validity, patients with higher education level and higher family income showed greater knowledge about hypertension. The instrument has a satisfactory clarity index and adequate validity, and can be used to evaluate the knowledge of hypertensive participants in cardiac rehabilitation programs.

  14. Predicting a contact's sensitivity to initial conditions using metrics of frictional coupling

    DOE PAGES

    Flicek, Robert C.; Hills, David A.; Brake, Matthew Robert W.

    2016-09-29

    This paper presents a method for predicting how sensitive a frictional contact’s steady-state behavior is to its initial conditions. Previous research has proven that if a contact is uncoupled, i.e. if slip displacements do not influence the contact pressure distribution, then its steady-state response is independent of initial conditions, but if the contact is coupled, the steady-state response depends on initial conditions. In this paper, two metrics for quantifying coupling in discrete frictional systems are examined. These metrics suggest that coupling is dominated by material dissimilarity due to Dundurs’ composite material parameter β when β ≥ 0.2, but geometric mismatchmore » becomes the dominant source of coupling for smaller values of β. Based on a large set of numerical simulations with different contact geometries, material combinations, and friction coefficients, a contact’s sensitivity to initial conditions is found to be correlated with the product of the coupling metric and the friction coefficient. For cyclic shear loading, this correlation is maintained for simulations with different contact geometries, material combinations, and friction coefficients. Furthermore, for cyclic bulk loading, the correlation is only maintained when the contact edge angle is held constant.« less

  15. Profiling the interaction mechanism of quinoline/quinazoline derivatives as MCHR1 antagonists: an in silico method.

    PubMed

    Wu, Mingwei; Li, Yan; Fu, Xinmei; Wang, Jinghui; Zhang, Shuwei; Yang, Ling

    2014-09-01

    Melanin concentrating hormone receptor 1 (MCHR1), a crucial regulator of energy homeostasis involved in the control of feeding and energy metabolism, is a promising target for treatment of obesity. In the present work, the up-to-date largest set of 181 quinoline/quinazoline derivatives as MCHR1 antagonists was subjected to both ligand- and receptor-based three-dimensional quantitative structure-activity (3D-QSAR) analysis applying comparative molecular field analysis (CoMFA) and comparative molecular similarity indices analysis (CoMSIA). The optimal predictable CoMSIA model exhibited significant validity with the cross-validated correlation coefficient (Q²) = 0.509, non-cross-validated correlation coefficient (R²(ncv)) = 0.841 and the predicted correlation coefficient (R²(pred)) = 0.745. In addition, docking studies and molecular dynamics (MD) simulations were carried out for further elucidation of the binding modes of MCHR1 antagonists. MD simulations in both water and lipid bilayer systems were performed. We hope that the obtained models and information may help to provide an insight into the interaction mechanism of MCHR1 antagonists and facilitate the design and optimization of novel antagonists as anti-obesity agents.

  16. Predicting a contact's sensitivity to initial conditions using metrics of frictional coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flicek, Robert C.; Hills, David A.; Brake, Matthew Robert W.

    This paper presents a method for predicting how sensitive a frictional contact’s steady-state behavior is to its initial conditions. Previous research has proven that if a contact is uncoupled, i.e. if slip displacements do not influence the contact pressure distribution, then its steady-state response is independent of initial conditions, but if the contact is coupled, the steady-state response depends on initial conditions. In this paper, two metrics for quantifying coupling in discrete frictional systems are examined. These metrics suggest that coupling is dominated by material dissimilarity due to Dundurs’ composite material parameter β when β ≥ 0.2, but geometric mismatchmore » becomes the dominant source of coupling for smaller values of β. Based on a large set of numerical simulations with different contact geometries, material combinations, and friction coefficients, a contact’s sensitivity to initial conditions is found to be correlated with the product of the coupling metric and the friction coefficient. For cyclic shear loading, this correlation is maintained for simulations with different contact geometries, material combinations, and friction coefficients. Furthermore, for cyclic bulk loading, the correlation is only maintained when the contact edge angle is held constant.« less

  17. Relationships between water quality parameters in rivers and lakes: BOD5, COD, NBOPs, and TOC.

    PubMed

    Lee, Jaewoong; Lee, Seunghyun; Yu, Soonju; Rhew, Doughee

    2016-04-01

    Biological oxygen demand (BOD5) or chemical oxygen demand (COD) analysis is widely used to evaluate organic pollutants in water systems as well as the efficiency of wastewater treatment plants. However, both analysis methods have restrictions such as being insensitive, imprecise, time-consuming, and the production of chemical waste. Therefore, total organic carbon (TOC) analysis for organic pollutants has been considered for an alternative analysis instead of BOD5 or COD. Several studies have investigated the replacement of BOD5 or COD with TOC in wastewater samples; however, few studies have investigated the relationships between water quality parameters in rivers and lakes. Therefore, this study evaluated the relationships between BOD5, COD, or NBOPs and TOC by the analysis of national water quality monitoring data of rivers and lakes for 5 years. High correlation coefficients (r) of 0.87 and 0.66 between BOD5 and TOC (p < 0.05) were obtained for rivers and lakes, respectively, and strong correlation coefficients (r) of 0.93 and 0.75 were observed between COD and TOC (p < 0.05) for rivers and lakes, respectively. The correlation coefficient (r) between NBOPs and TOC was 0.93 for rivers and 0.72 for lakes. The coefficients of determination (R 2) were 0.75 and 0.44 between BOD5 and TOC for rivers and lakes as well as were 0.87 and 0.57 between COD and TOC for rivers and lakes, respectively. The coefficient of determination (R 2) between NBOPs and TOC was 0.73 for rivers and 0.52 for lakes.

  18. Rapid classification of hairtail fish and pork freshness using an electronic nose based on the PCA method.

    PubMed

    Tian, Xiu-Ying; Cai, Qiang; Zhang, Yong-Ming

    2012-01-01

    We report a method for building a simple and reproducible electronic nose based on commercially available metal oxide sensors (MOS) to monitor the freshness of hairtail fish and pork stored at 15, 10, and 5 °C. After assembly in the laboratory, the proposed product was tested by a manufacturer. Sample delivery was based on the dynamic headspace method, and two features were extracted from the transient response of each sensor using an unsupervised principal component analysis (PCA) method. The compensation method and pattern recognition based on PCA are discussed in the current paper. PCA compensation can be used for all storage temperatures, however, pattern recognition differs according to storage conditions. Total volatile basic nitrogen (TVBN) and aerobic bacterial counts of the samples were measured simultaneously with the standard indicators of hairtail fish and pork freshness. The PCA models based on TVBN and aerobic bacterial counts were used to classify hairtail fish samples as "fresh" (TVBN ≤ 25 g and microbial counts ≤ 10(6) cfu/g) or "spoiled" (TVBN ≥ 25 g and microbial counts ≥ 10(6) cfu/g) and pork samples also as "fresh" (TVBN ≤ 15 g and microbial counts ≤ 10(6) cfu/g) or "spoiled" (TVBN ≥ 15 g and microbial counts ≥ 10(6) cfu/g). Good correlation coefficients between the responses of the electronic nose and the TVBN and aerobic bacterial counts of the samples were obtained. For hairtail fish, correlation coefficients were 0.97 and 0.91, and for pork, correlation coefficients were 0.81 and 0.88, respectively. Through laboratory simulation and field application, we were able to determine that the electronic nose could help ensure the shelf life of hairtail fish and pork, especially when an instrument is needed to take measurements rapidly. The results also showed that the electronic nose could analyze the process and level of spoilage for hairtail fish and pork.

  19. Effect of various refining processes for Kenaf Bast non-wood pulp fibers suspensions on heat transfer coefficient in circular pipe heat exchanger

    NASA Astrophysics Data System (ADS)

    Ahmed, Syed Muzamil; Kazi, S. N.; Khan, Ghulamullah; Sadri, Rad; Dahari, Mahidzal; Zubir, M. N. M.; Sayuti, M.; Ahmad, Pervaiz; Ibrahim, Rushdan

    2018-03-01

    Heat transfer coefficients were obtained for a range of non-wood kenaf bast pulp fiber suspensions flowing through a circular pipe heat exchanger test loop. The data were produced over a selected temperature and range of flow rates from the flow loop. It was found that the magnitude of the heat transfer coefficient of a fiber suspension is dependent on characteristics, concentration and pulping method of fiber. It was observed that at low concentration and high flow rates, the heat transfer coefficient values of suspensions were observed higher than that of the heat transfer coefficient values of water, on the other hand the heat transfer coefficient values of suspensions decreases at low flow rates and with the increase of their concentration. The heat transfer were affected by varying fiber characteristics, such as fiber length, fiber flexibility, fiber chemical and mechanical treatment as well as different pulping methods used to liberate the fibers. Heat transfer coefficient was decreased with the increase of fiber flexibility which was also observed by previous researchers. In the present work, the characteristics of fibers are correlated with the heat transfer coefficient of suspensions of the fibers. Deviations in fiber properties can be monitored from the flowing fiber suspensions by measuring heat transfer coefficient to adjust the degree of fiber refining treatment so that papers made from those fibers will be more uniform, consistent, within the product specification and retard the paper production loss.

  20. Multiscale Anomaly Detection and Image Registration Algorithms for Airborne Landmine Detection

    DTIC Science & Technology

    2008-05-01

    with the sensed image. The two- dimensional correlation coefficient r for two matrices A and B both of size M ×N is given by r = ∑ m ∑ n (Amn...correlation based method by matching features in a high- dimensional feature- space . The current implementation of the SIFT algorithm uses a brute-force...by repeatedly convolving the image with a Guassian kernel. Each plane of the scale

  1. Perturbed effects at radiation physics

    NASA Astrophysics Data System (ADS)

    Külahcı, Fatih; Şen, Zekâi

    2013-09-01

    Perturbation methodology is applied in order to assess the linear attenuation coefficient, mass attenuation coefficient and cross-section behavior with random components in the basic variables such as the radiation amounts frequently used in the radiation physics and chemistry. Additionally, layer attenuation coefficient (LAC) and perturbed LAC (PLAC) are proposed for different contact materials. Perturbation methodology provides opportunity to obtain results with random deviations from the average behavior of each variable that enters the whole mathematical expression. The basic photon intensity variation expression as the inverse exponential power law (as Beer-Lambert's law) is adopted for perturbation method exposition. Perturbed results are presented not only in terms of the mean but additionally the standard deviation and the correlation coefficients. Such perturbation expressions provide one to assess small random variability in basic variables.

  2. Efficient Storage Scheme of Covariance Matrix during Inverse Modeling

    NASA Astrophysics Data System (ADS)

    Mao, D.; Yeh, T. J.

    2013-12-01

    During stochastic inverse modeling, the covariance matrix of geostatistical based methods carries the information about the geologic structure. Its update during iterations reflects the decrease of uncertainty with the incorporation of observed data. For large scale problem, its storage and update cost too much memory and computational resources. In this study, we propose a new efficient storage scheme for storage and update. Compressed Sparse Column (CSC) format is utilized to storage the covariance matrix, and users can assign how many data they prefer to store based on correlation scales since the data beyond several correlation scales are usually not very informative for inverse modeling. After every iteration, only the diagonal terms of the covariance matrix are updated. The off diagonal terms are calculated and updated based on shortened correlation scales with a pre-assigned exponential model. The correlation scales are shortened by a coefficient, i.e. 0.95, every iteration to show the decrease of uncertainty. There is no universal coefficient for all the problems and users are encouraged to try several times. This new scheme is tested with 1D examples first. The estimated results and uncertainty are compared with the traditional full storage method. In the end, a large scale numerical model is utilized to validate this new scheme.

  3. Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions

    PubMed Central

    Kim, Yong-Wook

    2013-01-01

    . [Purpose] The purpose of the present study was to investigate the clinical usefulness (reliability and validity) of the pendulum test using a Noland-Kuckhoff (NK) table with an attached electrogoniometer to measure the spasticity of patients with brain lesions. [Subjects] The subjects were 31 patients with stroke or traumatic brain injury. [Methods] The intraclass correlation coefficient (ICC) was used to verify the test–retest reliability of spasticity measures obtained using the pendulum test. Pearson's product correlation coefficient was used to examine the validity of the pendulum test using the amplitude of the patellar tendon reflex (PTR) test, an objective and quantitative measure of spasticity. [Results] The test–retest reliability was high, reflecting a significant correlation between the test and the retest (ICCs = 0.95–0.97). A significant negative correlation was found between the amplitude of the PTR test and the four variables measured in the pendulum test (r = −0.77– −0.85). [Conclusion] The pendulum test using a NK table is an objective measure of spasticity and can be used in the clinical setting in place of more expensive and complicated equipment. Further studies are needed to investigate the therapeutic effect of this method on spasticity. PMID:24259775

  4. Clinical usefulness of the pendulum test using a NK table to measure the spasticity of patients with brain lesions.

    PubMed

    Kim, Yong-Wook

    2013-10-01

    . [Purpose] The purpose of the present study was to investigate the clinical usefulness (reliability and validity) of the pendulum test using a Noland-Kuckhoff (NK) table with an attached electrogoniometer to measure the spasticity of patients with brain lesions. [Subjects] The subjects were 31 patients with stroke or traumatic brain injury. [Methods] The intraclass correlation coefficient (ICC) was used to verify the test-retest reliability of spasticity measures obtained using the pendulum test. Pearson's product correlation coefficient was used to examine the validity of the pendulum test using the amplitude of the patellar tendon reflex (PTR) test, an objective and quantitative measure of spasticity. [Results] The test-retest reliability was high, reflecting a significant correlation between the test and the retest (ICCs = 0.95-0.97). A significant negative correlation was found between the amplitude of the PTR test and the four variables measured in the pendulum test (r = -0.77- -0.85). [Conclusion] The pendulum test using a NK table is an objective measure of spasticity and can be used in the clinical setting in place of more expensive and complicated equipment. Further studies are needed to investigate the therapeutic effect of this method on spasticity.

  5. Consistency of clinical biomechanical measures between three different institutions: implications for multi-center biomechanical and epidemiological research.

    PubMed

    Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E

    2014-05-01

    Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.

  6. Abrupt Change of the Transboundary Runoff and Its Influence on Water Security of Lanstang-Mekong River

    NASA Astrophysics Data System (ADS)

    Sang, Y. F.; Xie, P.; Ziyi, W.; Jiangyan, Z.; Qianjin, D.; Xu, L.

    2017-12-01

    As a significant manifestation of hydrological variability, abrupt change will obviously impact on the water security. To analyze what does the variation bring under changing environment, abrupt change detection should be a basic task, as well as variation level evaluation and hydrological frequency analysis. However, there lacks an effective method to reach those purposes systematically. Here we derived correlation coefficient between the original series and the jump-component series which is related to the difference degree of mean value before and after the abrupt change. Based on it, we proposed the moving-correlation-coefficient-based detection method and evaluated the significance of abrupt change as different levels related to the value of correlation coefficient. Then, with the obtained results, we calculated hydrological frequency in different situation (before and after the abrupt change). The approach above was employed to investigate the transboundary runoff of Lanstang-Mekong River at some kinds of time scale. We obtained the abrupt changes from runoff series of year, flood season and dry season which are almost the same. All the abrupt changes were significant which could reach to the moderate level. Compared with the past situation (before the abrupt change), the hydrological frequency in the current situation (after the abrupt change) indicated the water security of the water supply and flood control in the lower reaches of Lanstang-Mekong River could be guaranteed better, which is owed to the construction and operation of the water conservancy projects on the upper Lanstang-Mekong River.

  7. Evaluation of the kinetic energy of the torso by magneto-inertial measurement unit during the sit-to-stand movement.

    PubMed

    Lepetit, Kevin; Ben Mansour, Khalil; Boudaoud, Sofiane; Kinugawa-Bourron, Kiyoka; Marin, Frédéric

    2018-01-23

    Sit-to-stand tests are used in geriatrics as a qualitative issue in order to evaluate motor control and stability. In terms of measured indicators, it is traditionally the duration of the task that is reported, however it appears that the use of the kinetic energy as a new quantitative criterion allows getting a better understanding of musculoskeletal deficits of elderly subjects. The aim of this study was to determine the feasibility to obtain the measure of kinetic energy using magneto-inertial measurement units (MIMU) during sit-to-stand movements at various paces. 26 healthy subjects contributed to this investigation. Measured results were compared to a marker-based motion capture using the correlation coefficient and the normalized root mean square error (nRMSE). nRMSE were below 10% and correlation coefficients were over 0.97. In addition, errors on the mean kinetic energy were also investigated using Bland-Altman 95% limits of agreement (0.63 J-0.77 J), RMSE (0.29 J-0.38 J) and correlation coefficient (0.96-0.98). The results obtained highlighted that the method based on MIMU data could be an alternative to optoelectronic data acquisition to assess the kinetic energy of the torso during the sit-to-stand test, suggesting this method as being a promising alternative to determine kinetic energy during the sit-to-stand movement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. [Correlation of substrate structure and hydraulic characteristics in subsurface flow constructed wetlands].

    PubMed

    Bai, Shao-Yuan; Song, Zhi-Xin; Ding, Yan-Li; You, Shao-Hong; He, Shan

    2014-02-01

    The correlation of substrate structure and hydraulic characteristics was studied by numerical simulation combined with experimental method. The numerical simulation results showed that the permeability coefficient of matrix had a great influence on hydraulic efficiency in subsurface flow constructed wetlands. The filler with a high permeability coefficient had a worse flow field distribution in the constructed wetland with single layer structure. The layered substrate structure with the filler permeability coefficient increased from surface to bottom could avoid the short-circuited flow and dead-zones, and thus, increased the hydraulic efficiency. Two parallel pilot-scale constructed wetlands were built according to the numerical simulation results, and tracer experiments were conducted to validate the simulation results. The tracer experiment result showed that hydraulic characteristics in the layered constructed wetland were obviously better than that in the single layer system, and the substrate effective utilization rates were 0.87 and 0.49, respectively. It was appeared that numerical simulation would be favorable for substrate structure optimization in subsurface flow constructed wetlands.

  9. [Quantitative structure-gas chromatographic retention relationship of polycyclic aromatic sulfur heterocycles using molecular electronegativity-distance vector].

    PubMed

    Li, Zhenghua; Cheng, Fansheng; Xia, Zhining

    2011-01-01

    The chemical structures of 114 polycyclic aromatic sulfur heterocycles (PASHs) have been studied by molecular electronegativity-distance vector (MEDV). The linear relationships between gas chromatographic retention index and the MEDV have been established by a multiple linear regression (MLR) model. The results of variable selection by stepwise multiple regression (SMR) and the powerful predictive abilities of the optimization model appraised by leave-one-out cross-validation showed that the optimization model with the correlation coefficient (R) of 0.994 7 and the cross-validated correlation coefficient (Rcv) of 0.994 0 possessed the best statistical quality. Furthermore, when the 114 PASHs compounds were divided into calibration and test sets in the ratio of 2:1, the statistical analysis showed our models possesses almost equal statistical quality, the very similar regression coefficients and the good robustness. The quantitative structure-retention relationship (QSRR) model established may provide a convenient and powerful method for predicting the gas chromatographic retention of PASHs.

  10. Determination of diffusion coefficients of various livestock antibiotics in water at infinite dilution

    NASA Astrophysics Data System (ADS)

    Soriano, Allan N.; Adamos, Kristoni G.; Bonifacio, Pauline B.; Adornado, Adonis P.; Bungay, Vergel C.; Vairavan, Rajendaran

    2017-11-01

    The fate of antibiotics entering the environment raised concerns on the possible effect of antimicrobial resistance bacteria. Prediction of the fate and transport of these particles are needed to be determined, significantly the diffusion coefficient of antibiotic in water at infinite dilution. A systematic determination of diffusion coefficient of antibiotic in water at infinite dilution of five different kinds of livestock antibiotics namely: Amtyl, Ciprotyl, Doxylak Forte, Trisullak, and Vetracin Gold in the 293.15 to 313.15 K temperature range are reported through the use of the method involving the electrolytic conductivity measurements. A continuous stirred tank reactor is utilized to measure the electrolytic conductivities of the considered systems. These conductivities are correlated by using the Nernst-Haskell equation to determine the infinite dilution diffusion coefficient. Determined diffusion coefficients are based on the assumption that in dilute solution, these antibiotics behave as strong electrolyte from which H+ cation dissociate from the antibiotic's anion.

  11. New method: calculation of magnification factor from an intracardiac marker.

    PubMed

    Cha, S D; Incarvito, J; Maranhao, V

    1983-01-01

    In order to calculate a magnification factor (MF), an intracardiac marker (pigtail catheter with markers) was evaluated using a new formula and correlated with the conventional grid method. By applying the Pythagorean theorem and trigonometry, a new formula was developed, which is (formula; see text) In an experimental study, MF by the intracardiac markers was 0.71 +/- 0.15 (M +/- SD) and one by the grid method was 0.72 +/- 0.15, with a correlation coefficient of 0.96. In patients study, MF by the intracardiac markers was 0.77 +/- 0.06 and one by the grid method was 0.77 +/- 0.05. We conclude that this new method is simple and the results were comparable to the conventional grid method at mid-chest level.

  12. Anthropometry of Women of the U.S. Army--1977. Report Number 4. Correlation Coefficients

    DTIC Science & Technology

    1980-02-01

    S.... •, 0 76 x:. ADo5 //64 ! TECHNICAL REPORT NATICK/TR-80/016 (/ II ANTHROPOMETRY OF WOMEN OF THE U.S. ARMY-1977 Report No. 4 Correlation...NUMBER NATICK/TR-80/016 4. TITLE (and Subtitle) 5. TYPE OF REPORT & PERIOD COVERED ANTHROPOMETRY OF WOMEN OF THE U.S. ARMY--1977 Technical Report REPORT NO... Anthropometry Survey(s) Coefficients of correlation Measurement(s) U.S. Army Correlation coefficients Body size Military personnel Equation(s) Sizes

  13. DCCA cross-correlation coefficients reveals the change of both synchronization and oscillation in EEG of Alzheimer disease patients

    NASA Astrophysics Data System (ADS)

    Chen, Yingyuan; Cai, Lihui; Wang, Ruofan; Song, Zhenxi; Deng, Bin; Wang, Jiang; Yu, Haitao

    2018-01-01

    Alzheimer's disease (AD) is a degenerative disorder of neural system that affects mainly the older population. Recently, many researches show that the EEG of AD patients can be characterized by EEG slowing, enhanced complexity of the EEG signals, and EEG synchrony. In order to examine the neural synchrony at multi scales, and to find a biomarker that help detecting AD in diagnosis, detrended cross-correlation analysis (DCCA) of EEG signals is applied in this paper. Several parameters, namely DCCA coefficients in the whole brain, DCCA coefficients at a specific scale, maximum DCCA coefficient over the span of all time scales and the corresponding scale of such coefficients, were extracted to examine the synchronization, respectively. The results show that DCCA coefficients have a trend of increase as scale increases, and decreases as electrode distance increases. Comparing DCCA coefficients in AD patients with healthy controls, a decrease of synchronization in the whole brain, and a bigger scale corresponding to maximum correlation is discovered in AD patients. The change of max-correlation scale may relate to the slowing of oscillatory activities. Linear combination of max DCCA coefficient and max-correlation scale reaches a classification accuracy of 90%. From the above results, it is reasonable to conclude that DCCA coefficient reveals the change of both oscillation and synchrony in AD, and thus is a powerful tool to differentiate AD patients from healthy elderly individuals.

  14. Two-level image authentication by two-step phase-shifting interferometry and compressive sensing

    NASA Astrophysics Data System (ADS)

    Zhang, Xue; Meng, Xiangfeng; Yin, Yongkai; Yang, Xiulun; Wang, Yurong; Li, Xianye; Peng, Xiang; He, Wenqi; Dong, Guoyan; Chen, Hongyi

    2018-01-01

    A two-level image authentication method is proposed; the method is based on two-step phase-shifting interferometry, double random phase encoding, and compressive sensing (CS) theory, by which the certification image can be encoded into two interferograms. Through discrete wavelet transform (DWT), sparseness processing, Arnold transform, and data compression, two compressed signals can be generated and delivered to two different participants of the authentication system. Only the participant who possesses the first compressed signal attempts to pass the low-level authentication. The application of Orthogonal Match Pursuit CS algorithm reconstruction, inverse Arnold transform, inverse DWT, two-step phase-shifting wavefront reconstruction, and inverse Fresnel transform can result in the output of a remarkable peak in the central location of the nonlinear correlation coefficient distributions of the recovered image and the standard certification image. Then, the other participant, who possesses the second compressed signal, is authorized to carry out the high-level authentication. Therefore, both compressed signals are collected to reconstruct the original meaningful certification image with a high correlation coefficient. Theoretical analysis and numerical simulations verify the feasibility of the proposed method.

  15. A pilot study of river flow prediction in urban area based on phase space reconstruction

    NASA Astrophysics Data System (ADS)

    Adenan, Nur Hamiza; Hamid, Nor Zila Abd; Mohamed, Zulkifley; Noorani, Mohd Salmi Md

    2017-08-01

    River flow prediction is significantly related to urban hydrology impact which can provide information to solve any problems such as flood in urban area. The daily river flow of Klang River, Malaysia was chosen to be forecasted in this pilot study which based on phase space reconstruction. The reconstruction of phase space involves a single variable of river flow data to m-dimensional phase space in which the dimension (m) is based on the optimal values of Cao method. The results from the reconstruction of phase space have been used in the forecasting process using local linear approximation method. From our investigation, river flow at Klang River is chaotic based on the analysis from Cao method. The overall results provide good value of correlation coefficient. The value of correlation coefficient is acceptable since the area of the case study is influence by a lot of factors. Therefore, this pilot study may be proposed to forecast daily river flow data with the purpose of providing information about the flow of the river system in urban area.

  16. A novel method to quantify the adulteration of extra virgin olive oil with low-grade olive oils by UV-vis.

    PubMed

    Torrecilla, José S; Rojo, Ester; Domínguez, Juan C; Rodríguez, Francisco

    2010-02-10

    A simple and novel method to quantify adulterations of extra virgin olive oil (EVOO) with refined olive oil (ROO) and refined olive-pomace oil (ROPO) is described here. This method consists of calculating chaotic parameters (Lyapunov exponent, autocorrelation coefficients, and two fractal dimensions, CPs) from UV-vis scans of adulterated EVOO samples. These parameters have been successfully linearly correlated with the ROO or ROPO concentrations in 396 EVOO adulterated samples. By an external validation process, when the adulterating agent concentration is less than 10%, the integrated CPs/UV-vis model estimates the adulterant agent concentration with a mean correlation coefficient (estimated versus real concentration of low grade olive oil) greater than 0.97 and a mean square error of less than 1%. In light of these results, this detector is suitable not only to detect adulterations but also to measure impurities when, for instance, a higher grade olive oil is transferred to another storage tank in which lower grade olive oil was stored that had not been adequately cleaned.

  17. Parametric Method Performance for Dynamic 3'-Deoxy-3'-18F-Fluorothymidine PET/CT in Epidermal Growth Factor Receptor-Mutated Non-Small Cell Lung Carcinoma Patients Before and During Therapy.

    PubMed

    Kramer, Gerbrand Maria; Frings, Virginie; Heijtel, Dennis; Smit, E F; Hoekstra, Otto S; Boellaard, Ronald

    2017-06-01

    The objective of this study was to validate several parametric methods for quantification of 3'-deoxy-3'- 18 F-fluorothymidine ( 18 F-FLT) PET in advanced-stage non-small cell lung carcinoma (NSCLC) patients with an activating epidermal growth factor receptor mutation who were treated with gefitinib or erlotinib. Furthermore, we evaluated the impact of noise on accuracy and precision of the parametric analyses of dynamic 18 F-FLT PET/CT to assess the robustness of these methods. Methods : Ten NSCLC patients underwent dynamic 18 F-FLT PET/CT at baseline and 7 and 28 d after the start of treatment. Parametric images were generated using plasma input Logan graphic analysis and 2 basis functions-based methods: a 2-tissue-compartment basis function model (BFM) and spectral analysis (SA). Whole-tumor-averaged parametric pharmacokinetic parameters were compared with those obtained by nonlinear regression of the tumor time-activity curve using a reversible 2-tissue-compartment model with blood volume fraction. In addition, 2 statistically equivalent datasets were generated by countwise splitting the original list-mode data, each containing 50% of the total counts. Both new datasets were reconstructed, and parametric pharmacokinetic parameters were compared between the 2 replicates and the original data. Results: After the settings of each parametric method were optimized, distribution volumes (V T ) obtained with Logan graphic analysis, BFM, and SA all correlated well with those derived using nonlinear regression at baseline and during therapy ( R 2 ≥ 0.94; intraclass correlation coefficient > 0.97). SA-based V T images were most robust to increased noise on a voxel-level (repeatability coefficient, 16% vs. >26%). Yet BFM generated the most accurate K 1 values ( R 2 = 0.94; intraclass correlation coefficient, 0.96). Parametric K 1 data showed a larger variability in general; however, no differences were found in robustness between methods (repeatability coefficient, 80%-84%). Conclusion: Both BFM and SA can generate quantitatively accurate parametric 18 F-FLT V T images in NSCLC patients before and during therapy. SA was more robust to noise, yet BFM provided more accurate parametric K 1 data. We therefore recommend BFM as the preferred parametric method for analysis of dynamic 18 F-FLT PET/CT studies; however, SA can also be used. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  18. On the Equivalence of FCS and FRAP: Simultaneous Lipid Membrane Measurements.

    PubMed

    Macháň, Radek; Foo, Yong Hwee; Wohland, Thorsten

    2016-07-12

    Fluorescence correlation spectroscopy (FCS) and fluorescence recovery after photobleaching (FRAP) are widely used methods to determine diffusion coefficients. However, they often do not yield the same results. With the advent of camera-based imaging FCS, which measures the diffusion coefficient in each pixel of an image, and proper bleaching corrections, it is now possible to measure the diffusion coefficient by FRAP and FCS in the exact same images. We thus performed simultaneous FCS and FRAP measurements on supported lipid bilayers and live cell membranes to test how far the two methods differ in their results and whether the methodological differences, in particular the high bleach intensity in FRAP, the bleach corrections, and the fitting procedures in the two methods explain observed differences. Overall, we find that the FRAP bleach intensity does not measurably influence the diffusion in the samples, but that bleach correction and fitting introduce large uncertainties in FRAP. We confirm our results by simulations. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  19. Molecular dynamics calculation of rotational diffusion coefficient of a carbon nanotube in fluid.

    PubMed

    Cao, Bing-Yang; Dong, Ruo-Yu

    2014-01-21

    Rotational diffusion processes are correlated with nanoparticle visualization and manipulation techniques, widely used in nanocomposites, nanofluids, bioscience, and so on. However, a systematical methodology of deriving this diffusivity is still lacking. In the current work, three molecular dynamics (MD) schemes, including equilibrium (Green-Kubo formula and Einstein relation) and nonequilibrium (Einstein-Smoluchowski relation) methods, are developed to calculate the rotational diffusion coefficient, taking a single rigid carbon nanotube in fluid argon as a case. We can conclude that the three methods produce same results on the basis of plenty of data with variation of the calculation parameters (tube length, diameter, fluid temperature, density, and viscosity), indicative of the validity and accuracy of the MD simulations. However, these results have a non-negligible deviation from the theoretical predictions of Tirado et al. [J. Chem. Phys. 81, 2047 (1984)], which may come from several unrevealed factors of the theory. The three MD methods proposed in this paper can also be applied to other situations of calculating rotational diffusion coefficient.

  20. Reproducibility of abdominal fat assessment by ultrasound and computed tomography.

    PubMed

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.

  1. Use of the Method of Triads in the Validation of Sodium and Potassium Intake in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil)

    PubMed Central

    Pereira, Taísa Sabrina Silva; Cade, Nágela Valadão; Mill, José Geraldo; Sichieri, Rosely; Molina, Maria del Carmen Bisi

    2016-01-01

    Introduction Biomarkers are a good choice to be used in the validation of food frequency questionnaire due to the independence of their random errors. Objective To assess the validity of the potassium and sodium intake estimated using the Food Frequency Questionnaire ELSA-Brasil. Subjects/Methods A subsample of participants in the ELSA-Brasil cohort was included in this study in 2009. Sodium and potassium intake were estimated using three methods: Semi-quantitative food frequency questionnaire, 12-hour nocturnal urinary excretion and three 24-hour food records. Correlation coefficients were calculated between the methods, and the validity coefficient was calculated using the method of triads. The 95% confidence intervals for the validity coefficient were estimated using bootstrap sampling. Exact and adjacent agreement and disagreement of the estimated sodium and potassium intake quintiles were compared among three methods. Results The sample consisted of 246 participants, aged 53±8 years, 52% of women. Validity coefficient for sodium were considered weak (рfood frequency questionnaire actual intake = 0.37 and рbiomarker actual intake = 0.21) and moderate (рfood records actual intake 0.56). The validity coefficient were higher for potassium (рfood frequency questionnaire actual intake = 0.60; рbiomarker actual intake = 0.42; рfood records actual intake = 0.79). Conclusions: The Food Frequency Questionnaire ELSA-Brasil showed good validity in estimating potassium intake in epidemiological studies. For sodium validity was weak, likely due to the non-quantification of the added salt to prepared food. PMID:28030625

  2. Quantitative 4D Transcatheter Intraarterial Perfusion MR Imaging as a Method to Standardize Angiographic Chemoembolization Endpoints

    PubMed Central

    Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.

    2011-01-01

    PURPOSE We aimed to test the hypothesis that subjective angiographic endpoints during transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) exhibit consistency and correlate with objective intraprocedural reductions in tumor perfusion as determined by quantitative four dimensional (4D) transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging. MATERIALS AND METHODS This prospective study was approved by the institutional review board. Eighteen consecutive patients underwent TACE in a combined MR/interventional radiology (MR-IR) suite. Three board-certified interventional radiologists independently graded the angiographic endpoint of each procedure based on a previously described subjective angiographic chemoembolization endpoint (SACE) scale. A consensus SACE rating was established for each patient. Patients underwent quantitative 4D TRIP-MR imaging immediately before and after TACE, from which mean whole tumor perfusion (Fρ) was calculated. Consistency of SACE ratings between observers was evaluated using the intraclass correlation coefficient (ICC). The relationship between SACE ratings and intraprocedural TRIP-MR imaging perfusion changes was evaluated using Spearman’s rank correlation coefficient. RESULTS The SACE rating scale demonstrated very good consistency among all observers (ICC = 0.80). The consensus SACE rating was significantly correlated with both absolute (r = 0.54, P = 0.022) and percent (r = 0.85, P < 0.001) intraprocedural perfusion reduction. CONCLUSION The SACE rating scale demonstrates very good consistency between raters, and significantly correlates with objectively measured intraprocedural perfusion reductions during TACE. These results support the use of the SACE scale as a standardized alternative method to quantitative 4D TRIP-MR imaging to classify patients based on embolic endpoints of TACE. PMID:22021520

  3. Comparison and validation of the aerosol optical depth obtained with the Langley plot method in the UV-B from Brewer Ozone Spectrophotometer measurements

    NASA Astrophysics Data System (ADS)

    Cheymol, Anne; de Backer, Hugo; Josefsson, Weine; Stübi, René

    2006-08-01

    The Aerosol Optical Depths (AODs) retrieved from Brewer Ozone Spectrophotometer measurements with a method previously developed (Cheymol and De Backer, 2003) are now validated by comparisons between AODs from six Brewer spectrophotometers and two CSEM SPM2000 sunphotometers: two Brewer spectrophotometers 016 and 178 at Uccle in Belgium; one Brewer spectrophotometer 128 and one sunphotometer CSEM SPM2000 at Norrköping in Sweden; and three Brewer instruments 040, 072, 156 at Arosa and one CSEM SPM2000 sunphotometer at Davos in Switzerland. The comparison between AODs from Brewer spectrophotometer 128 at 320.1 nm and sunphotometer SPM2000 at 368 nm at Norrköping shows that the AODs obtained from the Brewer measurements with the Langley Plot Method (LPM) are very accurate if the neutral density filter spectral transmittances are well known: with the measured values of these filters, the correlation coefficient, the slope, and the intercept of the regression line are 0.98, 0.85 ± 0.004, and 0.02 ± 0.0014, respectively. The bias observed is mainly owing to the wavelength difference between the two instruments. The comparison between AODs from different Brewer spectrophotometers confirm that AODs will be in very good agreement if they are measured with several Brewer instruments at the same place: At Uccle, the correlation coefficient, slope, and intercept of the regression line are 0.98, 1.02 ± 0.003, and 0.06 ± 0.001, respectively; at Arosa, the comparisons between the AODs from three Brewer spectrophotometers 040, 072, and 156 give a correlation coefficient, a slope, and an intercept of the regression line above 0.94, 0.98 and below 0.04, respectively.

  4. Comparison and Agreement Between the Richmond Agitation-Sedation Scale and the Riker Sedation-Agitation Scale in Evaluating Patients’ Eligibility for Delirium Assessment in the ICU

    PubMed Central

    Guzman, Oscar; Campbell, Noll L.; Walroth, Todd; Tricker, Jason L.; Hui, Siu L.; Perkins, Anthony; Zawahiri, Mohammed; Buckley, John D.; Farber, Mark O.; Ely, E. Wesley; Boustani, Malaz A.

    2012-01-01

    Background: Delirium evaluation in patients in the ICU requires the use of an arousal/sedation assessment tool prior to assessing consciousness. The Richmond Agitation-Sedation Scale (RASS) and the Riker Sedation-Agitation Scale (SAS) are well-validated arousal/sedation tools. We sought to assess the concordance of RASS and SAS assessments in determining eligibility of patients in the ICU for delirium screening using the confusion assessment method for the ICU (CAM-ICU). Methods: We performed a prospective cohort study in the adult medical, surgical, and progressive (step-down) ICUs of a tertiary care, university-affiliated, urban hospital in Indianapolis, Indiana. The cohort included 975 admissions to the ICU between January and October 2009. Results: The outcome measures of interest were the correlation and agreement between RASS and SAS measurements. In 2,469 RASS and SAS paired screens, the rank correlation using the Spearman correlation coefficient was 0.91, and the agreement between the two screening tools for assessing CAM-ICU eligibility as estimated by the κ coefficient was 0.93. Analysis showed that 70.1% of screens were eligible for CAM-ICU assessment using RASS (7.1% sedated [RASS −3 to −1]; 62.6% calm [0]; and 0.4% restless, agitated [+1 to +3]), compared with 72.1% using SAS (5% sedated [SAS 3]; 66.5% calm [4]; and 0.6% anxious, agitated [5, 6]). In the mechanically ventilated subgroup, RASS identified 19.1% CAM-ICU eligible patients compared with 24.6% by SAS. The correlation coefficient in this subgroup was 0.70 and the agreement was 0.81. Conclusion: Both SAS and RASS led to similar rates of delirium assessment using the CAM-ICU. PMID:22539644

  5. [Correlation of molecular weight and nanofiltration mass transfer coefficient of phenolic acid composition from Salvia miltiorrhiza].

    PubMed

    Li, Cun-Yu; Wu, Xin; Gu, Jia-Mei; Li, Hong-Yang; Peng, Guo-Ping

    2018-04-01

    Based on the molecular sieving and solution-diffusion effect in nanofiltration separation, the correlation between initial concentration and mass transfer coefficient of three typical phenolic acids from Salvia miltiorrhiza was fitted to analyze the relationship among mass transfer coefficient, molecular weight and concentration. The experiment showed a linear relationship between operation pressure and membrane flux. Meanwhile, the membrane flux was gradually decayed with the increase of solute concentration. On the basis of the molecular sieving and solution-diffusion effect, the mass transfer coefficient and initial concentration of three phenolic acids showed a power function relationship, and the regression coefficients were all greater than 0.9. The mass transfer coefficient and molecular weight of three phenolic acids were negatively correlated with each other, and the order from high to low is protocatechualdehyde >rosmarinic acid> salvianolic acid B. The separation mechanism of nanofiltration for phenolic acids was further clarified through the analysis of the correlation of molecular weight and nanofiltration mass transfer coefficient. The findings provide references for nanofiltration separation, especially for traditional Chinese medicine with phenolic acids. Copyright© by the Chinese Pharmaceutical Association.

  6. An improved evaluation method for measuring TOC of the Longmaxi Formation shale in the Sichuan Basin, south China

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Hu, C.; Wang, M.

    2017-12-01

    The evaluation of total organic carbon (TOC) in shale using logging data is one of the most crucial steps in shale gas exploration. However, it didn't achieve the ideal effect for the application of `ΔlogR' method in the Longmaxi Formation shale of Sichuan Basin.The reason may be the organic matter carbonization in Longmaxi Formation. An improved evaluation method, using the classification by lithology and sedimentary structure: 1) silty mudstone (wellsite logging data show silty); 2) calcareous mudstone (calcareous content > 25%); 3) laminated mudstone (laminations are recognized by core and imaging logging technology); 4) massive mudstone (massive textures are recognized by core and imaging logging technology, was proposed. This study compares two logging evaluation methods for measuring TOC in shale: the △logR method and the new proposed method. The results showed that the correlation coefficient between the calculated TOC and the tested TOC, based on the △logR method, was only 0.17. The correlation coefficient obtained according to the new method reached 0.80. The calculation results illustrated that, because of the good correlation between lithologies and sedimentary structure zones and TOC of different types of shale, the shale reservoirs could be graded according to four shale types. The new proposed method is more efficient, faster, and has higher vertical resolution than the △logR method. In addition, a new software had been completed. It was found to be especially effective under conditions of insufficient data during the early stages of shale gas exploration in the Silurian Longmaxi Formation, Muai Syncline Belt, south of the Sichuan Basin.

  7. Automated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration method.

    PubMed

    Erchinger, Friedemann; Engjom, Trond; Gudbrandsen, Oddrun Anita; Tjora, Erling; Gilja, Odd H; Dimcevski, Georg

    2016-01-01

    We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p < 0.001). Correlation coefficient of fresh versus frozen samples conducted with automatic spectrophotometry (n = 25): r = 0.96 (p < 0.001) CONCLUSIONS: The measurement of bicarbonate in fresh and thawed samples by automatic spectrophotometrical analysis correlates excellent with the back titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution. Copyright © 2016 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  8. Is intra-bladder pressure measurement a reliable indicator for raised intra-abdominal pressure? A prospective comparative study.

    PubMed

    Al-Abassi, Abdulla Ahmed; Al Saadi, Azan Saleh; Ahmed, Faisal

    2018-06-19

    Intra-abdominal pressure (IAP) can be measured by several indirect methods; however, the urinary bladder is largely preferred. The aim of this study was to compare intra-bladder pressure (IBP) at different levels of IAPs and assess its reliability as an indirect method for IAP measurement. We compared IBP with IAP in twenty-one patients undergoing laparoscopic cholecystectomy under general anesthesia. Measurements were recorded at increasing levels of insufflation pressures to approximately 22 mmHg. Pearson's correlation coefficient was calculated to establish the relationship between the two pressure measurements and Bland-Altman analysis was used to assess the limits of agreement between the two methods of measurements. The urinary bladder pressures reflected well the pressures in the abdominal cavity. Pearson correlation coefficient showed a good correlation between the two measurement techniques (r = 0.966, p < 0.0001) and Bland-Altman analysis indicated that the 95% limits of agreement between the two methods ranged from - 2.83 to 2.64. This range is accepted both clinically and according to the recommendations of the World Society of Abdominal Compartment Syndrome (WSACS). Our study showed that IBP measurement is a simple, minimally invasive method that may reliably estimates IAP in patients placed in supine position. Measurements for pressures higher than 12 mmHg may be less reliable. When applied clinically, this should alert the clinician to take safety measures to avoid abdominal compartment syndrome (ACS).

  9. [Study on freshness evaluation of ice-stored large yellow croaker (Pseudosciaena crocea) using near infrared spectroscopy].

    PubMed

    Liu, Yuan; Chen, Wei-Hua; Hou, Qiao-Juan; Wang, Xi-Chang; Dong, Ruo-Yan; Wu, Hao

    2014-04-01

    Near infrared spectroscopy (NIR) was used in this experiment to evaluate the freshness of ice-stored large yellow croaker (Pseudosciaena crocea) during different storage periods. And the TVB-N was used as an index to evaluate the freshness. Through comparing the correlation coefficent and standard deviations of calibration set and validation set of models established by singly and combined using of different pretreatment methods, different modeling methods and different wavelength region, the best TVB-N models of ice-stored large yellow croaker sold in the market were established to predict the freshness quickly. According to the research, the model shows that the best performance could be established by using the normalization by closure (Ncl) with 1st derivative (Dbl) and normalization to unit length (Nle) with 1st derivative as the pretreated method and partial least square (PLS) as the modeling method combined with choosing the wavelength region of 5 000-7 144, and 7 404-10 000 cm(-1). The calibration model gave the correlation coefficient of 0.992, with a standard error of calibration of 1.045 and the validation model gave the correlation coefficient of 0.999, with a standard error of prediction of 0.990. This experiment attempted to combine several pretreatment methods and choose the best wavelength region, which has got a good result. It could have a good prospective application of freshness detection and quality evaluation of large yellow croaker in the market.

  10. Snapping Sharks, Maddening Mindreaders, and Interactive Images: Teaching Correlation.

    ERIC Educational Resources Information Center

    Mitchell, Mark L.

    Understanding correlation coefficients is difficult for students. A free computer program that helps introductory psychology students distinguish between positive and negative correlation, and which also teaches them to understand the differences between correlation coefficients of different size is described in this paper. The program is…

  11. Correlation and agreement of a digital and conventional method to measure arch parameters.

    PubMed

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p < 0.01) between all digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  12. EEG artifacts reduction by multivariate empirical mode decomposition and multiscale entropy for monitoring depth of anaesthesia during surgery.

    PubMed

    Liu, Quan; Chen, Yi-Feng; Fan, Shou-Zen; Abbod, Maysam F; Shieh, Jiann-Shing

    2017-08-01

    Electroencephalography (EEG) has been widely utilized to measure the depth of anaesthesia (DOA) during operation. However, the EEG signals are usually contaminated by artifacts which have a consequence on the measured DOA accuracy. In this study, an effective and useful filtering algorithm based on multivariate empirical mode decomposition and multiscale entropy (MSE) is proposed to measure DOA. Mean entropy of MSE is used as an index to find artifacts-free intrinsic mode functions. The effect of different levels of artifacts on the performances of the proposed filtering is analysed using simulated data. Furthermore, 21 patients' EEG signals are collected and analysed using sample entropy to calculate the complexity for monitoring DOA. The correlation coefficients of entropy and bispectral index (BIS) results show 0.14 ± 0.30 and 0.63 ± 0.09 before and after filtering, respectively. Artificial neural network (ANN) model is used for range mapping in order to correlate the measurements with BIS. The ANN method results show strong correlation coefficient (0.75 ± 0.08). The results in this paper verify that entropy values and BIS have a strong correlation for the purpose of DOA monitoring and the proposed filtering method can effectively filter artifacts from EEG signals. The proposed method performs better than the commonly used wavelet denoising method. This study provides a fully adaptive and automated filter for EEG to measure DOA more accuracy and thus reduce risk related to maintenance of anaesthetic agents.

  13. Analytical determination of propeller performance degradation due to ice accretion

    NASA Technical Reports Server (NTRS)

    Miller, T. L.

    1986-01-01

    A computer code has been developed which is capable of computing propeller performance for clean, glaze, or rime iced propeller configurations, thereby providing a mechanism for determining the degree of performance degradation which results from a given icing encounter. The inviscid, incompressible flow field at each specified propeller radial location is first computed using the Theodorsen transformation method of conformal mapping. A droplet trajectory computation then calculates droplet impingement points and airfoil collection efficiency for each radial location, at which point several user-selectable empirical correlations are available for determining the aerodynamic penalities which arise due to the ice accretion. Propeller performance is finally computed using strip analysis for either the clean or iced propeller. In the iced mode, the differential thrust and torque coefficient equations are modified by the drag and lift coefficient increments due to ice to obtain the appropriate iced values. Comparison with available experimental propeller icing data shows good agreement in several cases. The code's capability to properly predict iced thrust coefficient, power coefficient, and propeller efficiency is shown to be dependent on the choice of empirical correlation employed as well as proper specification of radial icing extent.

  14. Modal sound transmission loss of a single leaf panel: Effects of inter-modal coupling.

    PubMed

    Wang, Chong

    2015-06-01

    Sound transmission through a single leaf panel has mostly been discussed and explained by using the approaching wave concept, from which the well-known mass law can be derived. In this paper, the modal behavior in sound transmission coefficients is explored, and it is shown that the mutual modal radiation impedances in modal sound transmission coefficients may not be ignored even for a panel immersed in a light fluid. By introducing the equivalent modal impedance which incorporates the inter-modal coupling effect, an analytical expression for the modal sound transmission coefficient is derived, and the overall sound transmission coefficient is simply a modal superposition of modal sound transmission coefficients. A good correlation is obtained between analytical calculation and boundary element method. In addition, it is found that inter-modal coupling has noticeable effects in modal sound transmission coefficients in the subsonic region but may be ignored as modes become supersonic. It is also shown that the well-known mass law performance is attributed to all the supersonic modes.

  15. Progression of Mortality due to Diseases of the Circulatory System and Human Development Index in Rio de Janeiro Municipalities.

    PubMed

    Soares, Gabriel Porto; Klein, Carlos Henrique; Silva, Nelson Albuquerque de Souza E; Oliveira, Glaucia Maria Moraes de

    2016-10-01

    Diseases of the circulatory system (DCS) are the major cause of death in Brazil and worldwide. To correlate the compensated and adjusted mortality rates due to DCS in the Rio de Janeiro State municipalities between 1979 and 2010 with the Human Development Index (HDI) from 1970 onwards. Population and death data were obtained in DATASUS/MS database. Mortality rates due to ischemic heart diseases (IHD), cerebrovascular diseases (CBVD) and DCS adjusted by using the direct method and compensated for ill-defined causes. The HDI data were obtained at the Brazilian Institute of Applied Research in Economics. The mortality rates and HDI values were correlated by estimating Pearson linear coefficients. The correlation coefficients between the mortality rates of census years 1991, 2000 and 2010 and HDI data of census years 1970, 1980 and 1991 were calculated with discrepancy of two demographic censuses. The linear regression coefficients were estimated with disease as the dependent variable and HDI as the independent variable. In recent decades, there was a reduction in mortality due to DCS in all Rio de Janeiro State municipalities, mainly because of the decline in mortality due to CBVD, which was preceded by an elevation in HDI. There was a strong correlation between the socioeconomic indicator and mortality rates. The HDI progression showed a strong correlation with the decline in mortality due to DCS, signaling to the relevance of improvements in life conditions.

  16. The validity of an assessment of maximum angular velocity of knee extension (KE) using a gyroscope.

    PubMed

    Arai, Takeshi; Obuchi, Shuichi; Shiba, Yoshitaka; Omuro, Kazuya; Inaba, Yasuko; Kojima, Motonaga

    2012-01-01

    Although it is more important to assess the muscular power of the lower extremities than the strength, no simplified method for doing so has been found. The aim of this study was to assess the validity of the assessment of the angular velocity of KE using a gyroscope. Participants included 105 community-dwelling older people (55 women, 50 men, age ± standard deviation (SD) 75±5.3). Pearson correlation coefficients and Spearman rank-correlation coefficients were used to examine the relationships between the angular velocity of KE and functional performance measurements, a self-efficacy scale and health-related quality of life (HRQOL). The data from the gyroscope were significantly correlated with some physical functions such as muscle strength (r=0.304, p<0.01), and walking velocity (r=0.543, p<0.001). In addition, the joint angular velocity was significantly correlated with self-efficacy (r=0.219-0.329, p<0.01-0.05) and HRQOL (r=0.207-0.359, p<0.01-0.05). The absolute value of the correlation coefficient of angular velocity tended to be greater than that of the muscle strength for mobility functions such as walking velocity and the timed-up-and-go (TUG) test. In conclusion, it was found that the assessment of the angular velocity of the knee joint using a gyroscope could be a feasible and meaningful measurement in the geriatrics field. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Calcaneotalar ratio: a new concept in the estimation of the length of the calcaneus.

    PubMed

    David, Vikram; Stephens, Terry J; Kindl, Radek; Ang, Andy; Tay, Wei-Han; Asaid, Rafik; McCullough, Keith

    2015-01-01

    Maintaining the calcaneal length after calcaneal fractures is vital to restoring the normal biomechanics of the foot, because it acts as an important lever arm to the plantarflexors of the foot. However, estimation of the length of the calcaneus to be reconstructed in comminuted calcaneal fractures can be difficult. We propose a new method to reliably estimate the calcaneal length radiographically by defining the calcaneotalar length ratio. A total of 100 ankle radiographs with no fracture in the calcaneus or talus taken in skeletally mature patients were reviewed by 6 observers. The anteroposterior lengths of the calcaneus and talus were measured, and the calcaneotalar length ratio was determined. The ratio was then used to estimate the length of the calcaneus. Interobserver reliability was determined using Cronbach's α coefficient and Pearson's correlation coefficient. The mean length of the calcaneus was 75 ± 0.6 mm, and the mean length of the talus was 59 ± 0.5 mm. The calcaneotalar ratio was 1.3. Using this ratio and multiplying it by the talar length, the mean average estimated length of the calcaneus was within 0.7 mm of the known calcaneal length. Cronbach's α coefficient and Pearson's correlation coefficient showed excellent interobserver reliability. The proposed calcaneotalar ratio is a new and reliable method to radiographically estimate the normal length of the calcaneus when reconstructing the calcaneus. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Performance analysis of MIMO wireless optical communication system with Q-ary PPM over correlated log-normal fading channel

    NASA Astrophysics Data System (ADS)

    Wang, Huiqin; Wang, Xue; Lynette, Kibe; Cao, Minghua

    2018-06-01

    The performance of multiple-input multiple-output wireless optical communication systems that adopt Q-ary pulse position modulation over spatial correlated log-normal fading channel is analyzed in terms of its un-coded bit error rate and ergodic channel capacity. The analysis is based on the Wilkinson's method which approximates the distribution of a sum of correlated log-normal random variables to a log-normal random variable. The analytical and simulation results corroborate the increment of correlation coefficients among sub-channels lead to system performance degradation. Moreover, the receiver diversity has better performance in resistance of spatial correlation caused channel fading.

  19. Stochastic dynamics of uncoupled neural oscillators: Fokker-Planck studies with the finite element method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galan, Roberto F.; Urban, Nathaniel N.; Center for the Neural Basis of Cognition, Mellon Institute, Pittsburgh, Pennsylvania 15213

    We have investigated the effect of the phase response curve on the dynamics of oscillators driven by noise in two limit cases that are especially relevant for neuroscience. Using the finite element method to solve the Fokker-Planck equation we have studied (i) the impact of noise on the regularity of the oscillations quantified as the coefficient of variation, (ii) stochastic synchronization of two uncoupled phase oscillators driven by correlated noise, and (iii) their cross-correlation function. We show that, in general, the limit of type II oscillators is more robust to noise and more efficient at synchronizing by correlated noise thanmore » type I.« less

  20. A Small Leak Detection Method Based on VMD Adaptive De-Noising and Ambiguity Correlation Classification Intended for Natural Gas Pipelines.

    PubMed

    Xiao, Qiyang; Li, Jian; Bai, Zhiliang; Sun, Jiedi; Zhou, Nan; Zeng, Zhoumo

    2016-12-13

    In this study, a small leak detection method based on variational mode decomposition (VMD) and ambiguity correlation classification (ACC) is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF), an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM) and back propagation neural network (BP) methods.

  1. A Small Leak Detection Method Based on VMD Adaptive De-Noising and Ambiguity Correlation Classification Intended for Natural Gas Pipelines

    PubMed Central

    Xiao, Qiyang; Li, Jian; Bai, Zhiliang; Sun, Jiedi; Zhou, Nan; Zeng, Zhoumo

    2016-01-01

    In this study, a small leak detection method based on variational mode decomposition (VMD) and ambiguity correlation classification (ACC) is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF), an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM) and back propagation neural network (BP) methods. PMID:27983577

  2. Analysis of Vibration and Noise of Construction Machinery Based on Ensemble Empirical Mode Decomposition and Spectral Correlation Analysis Method

    NASA Astrophysics Data System (ADS)

    Chen, Yuebiao; Zhou, Yiqi; Yu, Gang; Lu, Dan

    In order to analyze the effect of engine vibration on cab noise of construction machinery in multi-frequency bands, a new method based on ensemble empirical mode decomposition (EEMD) and spectral correlation analysis is proposed. Firstly, the intrinsic mode functions (IMFs) of vibration and noise signals were obtained by EEMD method, and then the IMFs which have the same frequency bands were selected. Secondly, we calculated the spectral correlation coefficients between the selected IMFs, getting the main frequency bands in which engine vibration has significant impact on cab noise. Thirdly, the dominated frequencies were picked out and analyzed by spectral analysis method. The study result shows that the main frequency bands and dominated frequencies in which engine vibration have serious impact on cab noise can be identified effectively by the proposed method, which provides effective guidance to noise reduction of construction machinery.

  3. Can poison control data be used for pharmaceutical poisoning surveillance?

    PubMed

    Naun, Christopher A; Olsen, Cody S; Dean, J Michael; Olson, Lenora M; Cook, Lawrence J; Keenan, Heather T

    2011-05-01

    To determine the association between the frequencies of pharmaceutical exposures reported to a poison control center (PCC) and those seen in the emergency department (ED). A statewide population-based retrospective comparison of frequencies of ED pharmaceutical poisonings with frequencies of pharmaceutical exposures reported to a regional PCC. ED poisonings, identified by International Classification of Diseases, Version 9 (ICD-9) codes, were grouped into substance categories. Using a reproducible algorithm facilitated by probabilistic linkage, codes from the PCC classification system were mapped into the same categories. A readily identifiable subset of PCC calls was selected for comparison. Correlations between frequencies of quarterly exposures by substance categories were calculated using Pearson correlation coefficients and partial correlation coefficients with adjustment for seasonality. PCC reported exposures correlated with ED poisonings in nine of 10 categories. Partial correlation coefficients (r(p)) indicated strong associations (r(p)>0.8) for three substance categories that underwent large changes in their incidences (opiates, benzodiazepines, and muscle relaxants). Six substance categories were moderately correlated (r(p)>0.6). One category, salicylates, showed no association. Limitations Imperfect overlap between ICD-9 and PCC codes may have led to miscategorization. Substances without changes in exposure frequency have inadequate variability to detect association using this method. PCC data are able to effectively identify trends in poisonings seen in EDs and may be useful as part of a pharmaceutical poisoning surveillance system. The authors developed an algorithm-driven technique for mapping American Association of Poison Control Centers codes to ICD-9 codes and identified a useful subset of poison control exposures for analysis.

  4. Relationship between parent–infant attachment and parental satisfaction with supportive nursing care

    PubMed Central

    Ghadery-Sefat, Akram; Abdeyazdan, Zahra; Badiee, Zohreh; Zargham-Boroujeni, Ali

    2016-01-01

    Background: Parent–infant attachment is an important factor in accepting parenting role, accelerating infant survival, and adjusting to the environment outside the uterus. Since family supportive interventions can strengthen the parent–infant caring relationship, this study sought to investigate the relationship between mother–infant attachment and satisfaction of the mothers with the supportive nursing care received in the neonatal intensive care unit (NICU). Materials and Methods: In this descriptive–correlational study, 210 mothers with premature infants who were hospitalized in the NICUs affiliated to Isfahan Medical University hospitals took part. The data were collected via Maternal Postnatal Attachment Scale and researcher's self-tailored questionnaire based on Nurse Parent Support Tool. Pearson correlation coefficient and multiple linear regressions were used to analyze the collected data. Results: The results showed that the overall score of mother–infant attachment and the overall score of maternal satisfaction correlated with a correlation coefficient of r = 0.195. Also, the overall score of mother–infant attachment and mothers’ satisfaction scores in the emotional, communicative-informative, and self-confidence domains correlated with correlation coefficients of r = 0.182, r = 0.0.189, and r = 0.0.304, respectively. The results of multiple regression analysis revealed that about 15% of changes in the dependent variable (mother–infant attachment) could be explained by different dimensions of mothers’ satisfaction. Conclusions: The results of the study showed that mother–infant attachment improved by increasing mothers’ satisfaction of supportive nursing care. Therefore, it seems necessary to increase maternal satisfaction through given nursing care support, in order to promote mother–infant attachment. PMID:26985225

  5. [Prediction of soil adsorption coefficients of organic compounds in a wide range of soil types by soil column liquid chromatography].

    PubMed

    Guo, Rongbo; Chen, Jiping; Zhang, Qing; Wu, Wenzhong; Liang, Xinmiao

    2004-01-01

    Using the methanol-water mixtures as mobile phases of soil column liquid chromatography (SCLC), prediction of soil adsorption coefficients (K(d)) by SCLC was validated in a wide range of soil types. The correlations between the retention factors measured by SCLC and soil adsorption coefficients measured by batch experiments were studied for five soils with different properties, i.e., Eurosoil 1#, 2#, 3#, 4# and 5#. The results show that good correlations existed between the retention factors and soil adsorption coefficients for Eurosoil 1#, 2#, 3# and 4#. For Eurosoil 5# which has a pH value of near 3, the correlation between retention factors and soil adsorption coefficients was unsatisfactory using methanol-water as mobile phase of SCLC. However, a good correlation was obtained using a methanol-buffer mixture with pH 3 as the mobile phase. This study proved that the SCLC is suitable for the prediction of soil adsorption coefficients.

  6. The Effects of Methods of Imputation for Missing Values on the Validity and Reliability of Scales

    ERIC Educational Resources Information Center

    Cokluk, Omay; Kayri, Murat

    2011-01-01

    The main aim of this study is the comparative examination of the factor structures, corrected item-total correlations, and Cronbach-alpha internal consistency coefficients obtained by different methods used in imputation for missing values in conditions of not having missing values, and having missing values of different rates in terms of testing…

  7. C-Depth Method to Determine Diffusion Coefficient and Partition Coefficient of PCB in Building Materials.

    PubMed

    Liu, Cong; Kolarik, Barbara; Gunnarsen, Lars; Zhang, Yinping

    2015-10-20

    Polychlorinated biphenyls (PCBs) have been found to be persistent in the environment and possibly harmful. Many buildings are characterized with high PCB concentrations. Knowledge about partitioning between primary sources and building materials is critical for exposure assessment and practical remediation of PCB contamination. This study develops a C-depth method to determine diffusion coefficient (D) and partition coefficient (K), two key parameters governing the partitioning process. For concrete, a primary material studied here, relative standard deviations of results among five data sets are 5%-22% for K and 42-66% for D. Compared with existing methods, C-depth method overcomes the inability to obtain unique estimation for nonlinear regression and does not require assumed correlations for D and K among congeners. Comparison with a more sophisticated two-term approach implies significant uncertainty for D, and smaller uncertainty for K. However, considering uncertainties associated with sampling and chemical analysis, and impact of environmental factors, the results are acceptable for engineering applications. This was supported by good agreement between model prediction and measurement. Sensitivity analysis indicated that effective diffusion distance, contacting time of materials with primary sources, and depth of measured concentrations are critical for determining D, and PCB concentration in primary sources is critical for K.

  8. Evidence conflict measure based on OWA operator in open world

    PubMed Central

    Wang, Shiyu; Liu, Xiang; Zheng, Hanqing; Wei, Boya

    2017-01-01

    Dempster-Shafer evidence theory has been extensively used in many information fusion systems since it was proposed by Dempster and extended by Shafer. Many scholars have been conducted on conflict management of Dempster-Shafer evidence theory in past decades. However, how to determine a potent parameter to measure evidence conflict, when the given environment is in an open world, namely the frame of discernment is incomplete, is still an open issue. In this paper, a new method which combines generalized conflict coefficient, generalized evidence distance, and generalized interval correlation coefficient based on ordered weighted averaging (OWA) operator, to measure the conflict of evidence is presented. Through ordered weighted average of these three parameters, the combinatorial coefficient can still measure the conflict effectively when one or two parameters are not valid. Several numerical examples demonstrate the effectiveness of the proposed method. PMID:28542271

  9. Bootstrapping conformal field theories with the extremal functional method.

    PubMed

    El-Showk, Sheer; Paulos, Miguel F

    2013-12-13

    The existence of a positive linear functional acting on the space of (differences between) conformal blocks has been shown to rule out regions in the parameter space of conformal field theories (CFTs). We argue that at the boundary of the allowed region the extremal functional contains, in principle, enough information to determine the dimensions and operator product expansion (OPE) coefficients of an infinite number of operators appearing in the correlator under analysis. Based on this idea we develop the extremal functional method (EFM), a numerical procedure for deriving the spectrum and OPE coefficients of CFTs lying on the boundary (of solution space). We test the EFM by using it to rederive the low lying spectrum and OPE coefficients of the two-dimensional Ising model based solely on the dimension of a single scalar quasiprimary--no Virasoro algebra required. Our work serves as a benchmark for applications to more interesting, less known CFTs in the near future.

  10. Numerical simulation of transmission coefficient using c-number Langevin equation

    NASA Astrophysics Data System (ADS)

    Barik, Debashis; Bag, Bidhan Chandra; Ray, Deb Shankar

    2003-12-01

    We numerically implement the reactive flux formalism on the basis of a recently proposed c-number Langevin equation [Barik et al., J. Chem. Phys. 119, 680 (2003); Banerjee et al., Phys. Rev. E 65, 021109 (2002)] to calculate transmission coefficient. The Kramers' turnover, the T2 enhancement of the rate at low temperatures and other related features of temporal behavior of the transmission coefficient over a range of temperature down to absolute zero, noise correlation, and friction are examined for a double well potential and compared with other known results. This simple method is based on canonical quantization and Wigner quasiclassical phase space function and takes care of quantum effects due to the system order by order.

  11. Chemical Shift MR Imaging Methods for the Quantification of Transcatheter Lipiodol Delivery to the Liver: Preclinical Feasibility Studies in a Rodent Model

    PubMed Central

    Yin, Xiaoming; Guo, Yang; Li, Weiguo; Huo, Eugene; Zhang, Zhuoli; Nicolai, Jodi; Kleps, Robert A.; Hernando, Diego; Katsaggelos, Aggelos K.; Omary, Reed A.

    2012-01-01

    Purpose: To demonstrate the feasibility of using chemical shift magnetic resonance (MR) imaging fat-water separation methods for quantitative estimation of transcatheter lipiodol delivery to liver tissues. Materials and Methods: Studies were performed in accordance with institutional Animal Care and Use Committee guidelines. Proton nuclear MR spectroscopy was first performed to identify lipiodol spectral peaks and relative amplitudes. Next, phantoms were constructed with increasing lipiodol-water volume fractions. A multiecho chemical shift–based fat-water separation method was used to quantify lipiodol concentration within each phantom. Six rats served as controls; 18 rats underwent catheterization with digital subtraction angiography guidance for intraportal infusion of a 15%, 30%, or 50% by volume lipiodol-saline mixture. MR imaging measurements were used to quantify lipiodol delivery to each rat liver. Lipiodol concentration maps were reconstructed by using both single-peak and multipeak chemical shift models. Intraclass and Spearman correlation coefficients were calculated for statistical comparison of MR imaging–based lipiodol concentration and volume measurements to reference standards (known lipiodol phantom compositions and the infused lipiodol dose during rat studies). Results: Both single-peak and multipeak measurements were well correlated to phantom lipiodol concentrations (r2 > 0.99). Lipiodol volume measurements were progressively and significantly higher when comparing between animals receiving different doses (P < .05 for each comparison). MR imaging–based lipiodol volume measurements strongly correlated with infused dose (intraclass correlation coefficients > 0.93, P < .001) with both single- and multipeak approaches. Conclusion: Chemical shift MR imaging fat-water separation methods can be used for quantitative measurements of lipiodol delivery to liver tissues. © RSNA, 2012 PMID:22623693

  12. Value of three-dimensional volume rendering images in the assessment of the centrality index for preoperative planning in patients with renal masses.

    PubMed

    Sofia, C; Magno, C; Silipigni, S; Cantisani, V; Mucciardi, G; Sottile, F; Inferrera, A; Mazziotti, S; Ascenti, G

    2017-01-01

    To evaluate the precision of the centrality index (CI) measurement on three-dimensional (3D) volume rendering technique (VRT) images in patients with renal masses, compared to its standard measurement on axial images. Sixty-five patients with renal lesions underwent contrast-enhanced multidetector (MD) computed tomography (CT) for preoperative imaging. Two readers calculated the CI on two-dimensional axial images and on VRT images, measuring it in the plane that the tumour and centre of the kidney were lying in. Correlation and agreement of interobserver measurements and inter-method results were calculated using intraclass correlation (ICC) coefficients and the Bland-Altman method. Time saving was also calculated. The correlation coefficients were r=0.99 (p<0.05) and r=0.99 (p<0.05) for both the CI on axial and VRT images, with an ICC of 0.99, and 0.99, respectively. Correlation between the two methods of measuring the CI on VRT and axial CT images was r=0.99 (p<0.05). The two methods showed a mean difference of -0.03 (SD 0.13). Mean time saving per each examination with VRT was 45.5%. The present study showed that VRT and axial images produce almost identical values of CI, with the advantages of greater ease of execution and a time saving of almost 50% for 3D VRT images. In addition, VRT provides an integrated perspective that can better assist surgeons in clinical decision making and in operative planning, suggesting this technique as a possible standard method for CI measurement. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Temporal correlation coefficient for directed networks.

    PubMed

    Büttner, Kathrin; Salau, Jennifer; Krieter, Joachim

    2016-01-01

    Previous studies dealing with network theory focused mainly on the static aggregation of edges over specific time window lengths. Thus, most of the dynamic information gets lost. To assess the quality of such a static aggregation the temporal correlation coefficient can be calculated. It measures the overall possibility for an edge to persist between two consecutive snapshots. Up to now, this measure is only defined for undirected networks. Therefore, we introduce the adaption of the temporal correlation coefficient to directed networks. This new methodology enables the distinction between ingoing and outgoing edges. Besides a small example network presenting the single calculation steps, we also calculated the proposed measurements for a real pig trade network to emphasize the importance of considering the edge direction. The farm types at the beginning of the pork supply chain showed clearly higher values for the outgoing temporal correlation coefficient compared to the farm types at the end of the pork supply chain. These farm types showed higher values for the ingoing temporal correlation coefficient. The temporal correlation coefficient is a valuable tool to understand the structural dynamics of these systems, as it assesses the consistency of the edge configuration. The adaption of this measure for directed networks may help to preserve meaningful additional information about the investigated network that might get lost if the edge directions are ignored.

  14. Reliability of bioimpedance analysis compared with other adiposity measurements in children: the FLVS II Study.

    PubMed

    Kettaneh, A; Heude, B; Lommez, A; Borys, J M; Ducimetière, P; Charles, M A

    2005-12-01

    To evaluate the reproducibility of the measurement of% body fat by bipedal biometrical impedance analysis (BIA) compared with anthropometric measurements of adiposity in children and the correlations between these methods in children and adults. A cross-sectional study in a total of 1080 adults and children enrolled in 1999 in the Fleurbaix-Laventie Ville Santé II (FLVS II) population-based study in northern France. The reproducibility of anthropometrical and BIA methods was determined by a nested analysis of variance of repeated measurements by 2 investigators and a bipedal BIA device (Tanita TBF 310) in 64 pupils of two 5th grade classes. The correlation of BIA and anthropometric adiposity measurements with the unknown relative fat mass or volume of the body estimated by a latent adiposity variable (LAV) was established by the triads' method in 1080 subjects of the FLVS II cohort. The reproducibility was similar for the sum of skinfolds, waist circumference and BIA% fat measurements (intraclass correlation coefficients: 0.979-0.992). Correlation coefficient between BIA body fat% and the LAV was higher than 0.86 in all sex and Tanner stage related groups, and similar in children and adults, except in pubertal boys (0.76). With a high level of reproducibility, foot-to-foot BIA analysis provides a valuable measurement of total% fat for epidemiologic studies in children. However further studies are needed before extrapolating these results to overweight children.

  15. Synthesis of linear regression coefficients by recovering the within-study covariance matrix from summary statistics.

    PubMed

    Yoneoka, Daisuke; Henmi, Masayuki

    2017-06-01

    Recently, the number of regression models has dramatically increased in several academic fields. However, within the context of meta-analysis, synthesis methods for such models have not been developed in a commensurate trend. One of the difficulties hindering the development is the disparity in sets of covariates among literature models. If the sets of covariates differ across models, interpretation of coefficients will differ, thereby making it difficult to synthesize them. Moreover, previous synthesis methods for regression models, such as multivariate meta-analysis, often have problems because covariance matrix of coefficients (i.e. within-study correlations) or individual patient data are not necessarily available. This study, therefore, proposes a brief explanation regarding a method to synthesize linear regression models under different covariate sets by using a generalized least squares method involving bias correction terms. Especially, we also propose an approach to recover (at most) threecorrelations of covariates, which is required for the calculation of the bias term without individual patient data. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. A method for estimating the incident PAR on inclined surfaces

    NASA Astrophysics Data System (ADS)

    Xie, Xiaoping; Gao, Wei; Gao, Zhiqiang

    2008-08-01

    A new simple model has been developed that incorporates Digital Elevation Model (DEM) and Moderate Resolution Imaging Spectroradiometer (MODIS) products to produce incident photosynthetically active radiation (PAR) for tilted surface. The method is based on a simplification of the general radiative transfer equation, which considers five major processes of attenuation of solar radiation: 1) Rayleigh scattering, 2) absorption by ozone and water vapor, 3) aerosol scattering, 4) multiple reflectance between surface and atmosphere, and 5) three terrain factors: slope and aspect, isotropic sky view factor, and additional radiation by neighbor reflectance. A comparison of the model results with observational data from the Yucheng and Changbai Mountain sites of the Chinese Ecosystem Research Network (CERN) shows the correlation coefficient as 0.929 and 0.904, respectively. A comparison of the model results with the 2006 filed measured PAR in the Yucheng and Changbai sites shows the correlation coefficient as 0.929 and 0.904, respectively, and the average percent error as 10% and 15%, respectively.

  17. Scaling digital radiographs for templating in total hip arthroplasty using conventional acetate templates independent of calibration markers.

    PubMed

    Brew, Christopher J; Simpson, Philip M; Whitehouse, Sarah L; Donnelly, William; Crawford, Ross W; Hubble, Matthew J W

    2012-04-01

    We describe a scaling method for templating digital radiographs using conventional acetate templates independent of template magnification without the need for a calibration marker. The mean magnification factor for the radiology department was determined (119.8%; range, 117%-123.4%). This fixed magnification factor was used to scale the radiographs by the method described. Thirty-two femoral heads on postoperative total hip arthroplasty radiographs were then measured and compared with the actual size. The mean absolute accuracy was within 0.5% of actual head size (range, 0%-3%) with a mean absolute difference of 0.16 mm (range, 0-1 mm; SD, 0.26 mm). Intraclass correlation coefficient showed excellent reliability for both interobserver and intraobserver measurements with intraclass correlation coefficient scores of 0.993 (95% CI, 0.988-0.996) for interobserver measurements and intraobserver measurements ranging between 0.990 and 0.993 (95% CI, 0.980-0.997). Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  18. Variable distributional characteristics of substrate utilization patterns in activated sludge plants in Kuwait.

    PubMed

    Al-Mutairi, N Z

    2009-02-01

    The objective of this study was to determine the magnitude of microbial functional potential and community structure between three different WWTPs using the Lorenz curve method and to find the effect of seasonal variation on patterns of substrate utilization. Lorenz curve method was sensitive enough to detect short-term changes in microbial functional diversity between Riqqa, Umm Al-Haiman and Al-Jahra activated sludge systems and showed seasonal variations of the utilized carbon sources. Gini coefficient ranged from 0.21 to 0.8. Lorenz curves seemed particularly suitable to present microbial heterogeneity in term of inequality and to highlight the relative contribution of low-and high functional diversity for the three different types of mixed liquors. Correlation analysis of the experimental data show that the complement of the Gini coefficient was strongly and positively correlated with the Shannon index (r(xy)=0.89), evenness (r(xy)=0.91), and AWCD (r(xy)=0.95) at the 95% level of significance (alpha=0.05).

  19. Recall of past use of mobile phone handsets.

    PubMed

    Parslow, R C; Hepworth, S J; McKinney, P A

    2003-01-01

    Previous studies investigating health effects of mobile phones have based their estimation of exposure on self-reported levels of phone use. This UK validation study assesses the accuracy of reported voice calls made from mobile handsets. Data collected by postal questionnaire from 93 volunteers was compared to records obtained prospectively over 6 months from four network operators. Agreement was measured for outgoing calls using the kappa statistic, log-linear modelling, Spearman correlation coefficient and graphical methods. Agreement for number of calls gained moderate classification (kappa = 0.39) with better agreement for duration (kappa = 0.50). Log-linear modelling produced similar results. The Spearman correlation coefficient was 0.48 for number of calls and 0.60 for duration. Graphical agreement methods demonstrated patterns of over-reporting call numbers (by a factor of 1.7) and duration (by a factor of 2.8). These results suggest that self-reported mobile phone use may not fully represent patterns of actual use. This has implications for calculating exposures from questionnaire data.

  20. Characterizing air quality data from complex network perspective.

    PubMed

    Fan, Xinghua; Wang, Li; Xu, Huihui; Li, Shasha; Tian, Lixin

    2016-02-01

    Air quality depends mainly on changes in emission of pollutants and their precursors. Understanding its characteristics is the key to predicting and controlling air quality. In this study, complex networks were built to analyze topological characteristics of air quality data by correlation coefficient method. Firstly, PM2.5 (particulate matter with aerodynamic diameter less than 2.5 μm) indexes of eight monitoring sites in Beijing were selected as samples from January 2013 to December 2014. Secondly, the C-C method was applied to determine the structure of phase space. Points in the reconstructed phase space were considered to be nodes of the network mapped. Then, edges were determined by nodes having the correlation greater than a critical threshold. Three properties of the constructed networks, degree distribution, clustering coefficient, and modularity, were used to determine the optimal value of the critical threshold. Finally, by analyzing and comparing topological properties, we pointed out that similarities and difference in the constructed complex networks revealed influence factors and their different roles on real air quality system.

  1. Concurrent Validity Between Live and Home Video Observations Using the Alberta Infant Motor Scale

    PubMed Central

    van Dam, Ellen; van Haastert, Ingrid C.; Nuysink, Jacqueline

    2017-01-01

    Purpose: Serial assessment of gross motor development of infants at risk is an established procedure in neonatal follow-up clinics. Assessments based on home video recordings could be a relevant addition. Methods: In 48 infants (1.5-19 months), the concurrent validity of 2 applications was examined using the Alberta Infant Motor Scale: (1) a home video made by parents and (2) simultaneous observation on-site by a pediatric physical therapist. Parents' experiences were explored using a questionnaire. Results: The intraclass correlation coefficient agreement between live and home video assessment was 0.99, with a standard error of measurement of 1.41 items. Intra- and interrater reliability: intraclass correlation coefficients were more than 0.99. According to 94% of the parents, recording their infant's movement repertoire was easy to perform. Conclusion: Assessing the Alberta Infant Motor Scale based on home video recordings is comparable to assessment by live observation. The video method is a promising application that can be used with low burden for parents and infants. PMID:28350771

  2. Correlation characteristics of phase and amplitude chimeras in an ensemble of nonlocally coupled maps

    NASA Astrophysics Data System (ADS)

    Vadivasova, T. E.; Strelkova, G. I.; Bogomolov, S. A.; Anishchenko, V. S.

    2017-01-01

    Correlation characteristics of chimera states have been calculated using the coefficient of mutual correlation of elements in a closed-ring ensemble of nonlocally coupled chaotic maps. Quantitative differences between the coefficients of mutual correlation for phase and amplitude chimeras are established for the first time.

  3. Extensive database of liquid phase diffusion coefficients of some frequently used test molecules in reversed-phase liquid chromatography and hydrophilic interaction liquid chromatography.

    PubMed

    Song, Huiying; Vanderheyden, Yoachim; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre

    2016-07-15

    Diffusion plays an important role in all aspects of band broadening in chromatography. An accurate knowledge of molecular diffusion coefficients in different mobile phases is therefore crucial in fundamental column performance studies. Correlations available in literature, such as the Wilke-Chang equation, can provide good approximations of molecular diffusion under reversed-phase conditions. However, these correlations have been demonstrated to be less accurate for mobile phases containing a large percentage of acetonitrile, as is the case in hydrophilic interaction liquid chromatography. A database of experimentally measured molecular diffusion coefficients of some 45 polar and apolar compounds that are frequently used as test molecules under hydrophilic interaction liquid chromatography and reversed-phase conditions is therefore presented. Special attention is given to diffusion coefficients of polar compounds obtained in large percentages of acetonitrile (>90%). The effect of the buffer concentration (5-10mM ammonium acetate) on the obtained diffusion coefficients is investigated and is demonstrated to mainly influence the molecular diffusion of charged molecules. Diffusion coefficients are measured using the Taylor-Aris method and hence deduced from the peak broadening of a solute when flowing through a long open tube. The validity of the set-up employed for the measurement of the diffusion coefficients is demonstrated by ruling out the occurrence of longitudinal diffusion, secondary flow interactions and extra-column effects, while it is also shown that radial equilibration in the 15m long capillary is effective. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt.

    PubMed

    Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu

    2016-07-01

    [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

  5. Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography

    PubMed Central

    Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2013-01-01

    OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume < −950 HU of each lobe using (i) the slice-by-slice method (reference standard), (ii) number of segments method, and (iii) semi-automatic and (iv) automatic computer-aided diagnosis. We determined Pearson correlation coefficients between the reference standard and the three other methods for lobar volumes and emphysematous lobar volumes. We also compared the relative errors among the three measurement methods. RESULTS Both semi-automatic and automatic computer-aided diagnosis results were more strongly correlated with the reference standard than the number of segments method. The correlation coefficients for automatic computer-aided diagnosis were slightly lower than those for semi-automatic computer-aided diagnosis because there was one outlier among 50 cases (2%) in the right upper lobe and two outliers among 50 cases (4%) in the other lobes. The number of segments method relative error was significantly greater than those for semi-automatic and automatic computer-aided diagnosis (P < 0.001). The computational time for automatic computer-aided diagnosis was 1/2 to 2/3 than that of semi-automatic computer-aided diagnosis. CONCLUSIONS A novel lobar volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418

  6. Diagnostic tests in HIV management: a review of clinical and laboratory strategies to monitor HIV-infected individuals in developing countries.

    PubMed Central

    Kimmel, April D.; Losina, Elena; Freedberg, Kenneth A.; Goldie, Sue J.

    2006-01-01

    We conducted a systematic review on the performance of diagnostic tests for clinical and laboratory monitoring of HIV-infected adults in developing countries. Diagnostic test information collected from computerized databases, bibliographies and the Internet were categorized as clinical (non-laboratory patient information), immunologic (information from immunologic laboratory tests), or virologic (information from virologic laboratory tests). Of the 51 studies selected for the review 28 assessed immunologic tests, 12 virologic tests and seven clinical and immunologic tests. Methods of performance evaluation were primarily sensitivity and specificity for the clinical category and correlation coefficients for immunologic and virologic categories. In the clinical category, the majority of test performance measures was reported as >70% sensitive and >65% specific. In the immunologic category, correlation coefficients ranged from r=0.54 to r=0.99 for different CD4 count enumeration techniques, while correlation for CD4 and total lymphocyte counts was between r=0.23 and r=0.74. In the virologic category, correlation coefficients for different human immunodeficiency virus (HIV) ribonucleic acid (RNA) quantification techniques ranged from r=0.54 to r=0.90. Future research requires consensus on designing studies, and collecting and reporting data useful for decision-makers. We recommend classifying information into clinically relevant categories, using a consistent definition of disease across studies and providing measures of both association and accuracy. PMID:16878233

  7. Constructing a bivariate distribution function with given marginals and correlation: application to the galaxy luminosity function

    NASA Astrophysics Data System (ADS)

    Takeuchi, Tsutomu T.

    2010-08-01

    We provide an analytic method to construct a bivariate distribution function (DF) with given marginal distributions and correlation coefficient. We introduce a convenient mathematical tool, called a copula, to connect two DFs with any prescribed dependence structure. If the correlation of two variables is weak (Pearson's correlation coefficient |ρ| < 1/3), the Farlie-Gumbel-Morgenstern (FGM) copula provides an intuitive and natural way to construct such a bivariate DF. When the linear correlation is stronger, the FGM copula cannot work anymore. In this case, we propose using a Gaussian copula, which connects two given marginals and is directly related to the linear correlation coefficient between two variables. Using the copulas, we construct the bivariate luminosity function (BLF) and discuss its statistical properties. We focus especially on the far-infrared-far-ulatraviolet (FUV-FIR) BLF, since these two wavelength regions are related to star-formation (SF) activity. Though both the FUV and FIR are related to SF activity, the univariate LFs have a very different functional form: the former is well described by the Schechter function whilst the latter has a much more extended power-law-like luminous end. We construct the FUV-FIR BLFs using the FGM and Gaussian copulas with different strengths of correlation, and examine their statistical properties. We then discuss some further possible applications of the BLF: the problem of a multiband flux-limited sample selection, the construction of the star-formation rate (SFR) function, and the construction of the stellar mass of galaxies (M*)-specific SFR (SFR/M*) relation. The copulas turn out to be a very useful tool to investigate all these issues, especially for including complicated selection effects.

  8. Channel correlation of free space optical communication systems with receiver diversity in non-Kolmogorov atmospheric turbulence

    NASA Astrophysics Data System (ADS)

    Ma, Jing; Fu, Yulong; Tan, Liying; Yu, Siyuan; Xie, Xiaolong

    2018-05-01

    Spatial diversity as an effective technique to mitigate the turbulence fading has been widely utilized in free space optical (FSO) communication systems. The received signals, however, will suffer from channel correlation due to insufficient spacing between component antennas. In this paper, the new expressions of the channel correlation coefficient and specifically its components (the large- and small-scale channel correlation coefficients) for a plane wave with aperture effects are derived for horizontal link in moderate-to-strong turbulence, using a non-Kolmogorov spectrum that has a generalized power law in the range of 3-4 instead of the fixed classical Kolmogorov power law of 11/3. And then the influence of power law variations on the channel correlation coefficient and its components are analysed. The numerical results indicated that various value of the power law lead to varying effects on the channel correlation coefficient and its components. This work will help with the further investigation on the fading correlation in spatial diversity systems.

  9. Measurement of the Diffusion Coefficient of Water in RP-3 and RP-5 Jet Fuels Using Digital Holography Interferometry

    NASA Astrophysics Data System (ADS)

    Li, Chaoyue; Feng, Shiyu; Shao, Lei; Pan, Jun; Liu, Weihua

    2018-04-01

    The diffusion coefficient of water in jet fuel was measured employing double-exposure digital holographic interferometry to clarify the diffusion process and make the aircraft fuel system safe. The experimental method and apparatus are introduced in detail, and the digital image processing program is coded in MATLAB according to the theory of the Fourier transform. At temperatures ranging from 278.15 K to 333.15 K in intervals of 5 K, the diffusion coefficient of water in RP-3 and RP-5 jet fuels ranges from 2.6967 × 10 -10 m2·s-1 to 8.7332 × 10 -10 m2·s-1 and from 2.3517 × 10 -10 m2·s-1 to 8.0099 × 10-10 m2·s-1, respectively. The relationship between the measured diffusion coefficient and temperature can be well fitted by the Arrhenius law. The diffusion coefficient of water in RP-3 jet fuel is higher than that of water in RP-5 jet fuel at the same temperature. Furthermore, the viscosities of the two jet fuels were measured and found to be expressible in the form of the Arrhenius equation. The relationship among the diffusion coefficient, viscosity and temperature is analyzed according to the classic prediction model, namely the Stokes-Einstein correlation, and this correlation is further revised via experimental data to obtain a more accurate predication result.

  10. Accurate virial coefficients of gaseous krypton from state-of-the-art ab initio potential and polarizability of the krypton dimer

    NASA Astrophysics Data System (ADS)

    Song, Bo; Waldrop, Jonathan M.; Wang, Xiaopo; Patkowski, Konrad

    2018-01-01

    We have developed a new krypton-krypton interaction-induced isotropic dipole polarizability curve based on high-level ab initio methods. The determination was carried out using the coupled-cluster singles and doubles plus perturbative triples method with very large basis sets up to augmented correlation-consistent sextuple zeta as well as the corrections for core-core and core-valence correlation and relativistic effects. The analytical function of polarizability and our recently constructed reference interatomic potential [J. M. Waldrop et al., J. Chem. Phys. 142, 204307 (2015)] were used to predict the thermophysical and electromagnetic properties of krypton gas. The second pressure, acoustic, and dielectric virial coefficients were computed for the temperature range of 116 K-5000 K using classical statistical mechanics supplemented with high-order quantum corrections. The virial coefficients calculated were compared with the generally less precise available experimental data as well as with values computed from other potentials in the literature {in particular, the recent highly accurate potential of Jäger et al. [J. Chem. Phys. 144, 114304 (2016)]}. The detailed examination in this work suggests that the present theoretical prediction can be applied as reference values in disciplines involving thermophysical and electromagnetic properties of krypton gas.

  11. Validity and reproducibility of electrical impedance tomography for measurement of calf blood flow in healthy subjects.

    PubMed

    Vonk Noordegraaf, A; Kunst, P W; Janse, A; Smulders, R A; Heethaar, R M; Postmus, P E; Faes, T J; de Vries, P M

    1997-03-01

    The Sheffield electrical impedance tomography; (EIT) system produces images of changes in the distribution of resistivity within tissue. The paper reports on the application of electrical impedance tomography in monitoring volume changes in the limb during venous occlusion. The aim of the study is to assess the feasibility, reproducibility and validity of calf blood flow measurements by EIT. In 14 healthy volunteers calf blood flow is compared, as determined in a calf segment by strain-gauge plethysmography (SGP), with the impedance changes measured by EIT during rest and post-ischaemic hyperaemia. The measurements are repeated to assess reproducibility. The reproducibility for the EIT, assessed from the repeated measurements and expressed as a reproducibility coefficient, is 0.88 during rest and 0.89 during hyperaemia. The reproducibility coefficient for SGP data is 0.83 at rest and 0.67 during hyperaemia. Flow measurements, assessed by means of two methods, correlate well at rest (r = 0.89), but only moderately during hyperaemia (r = 0.51). The correlation coefficient for the pooled flow measurements is 0.98. It is concluded that EIT is a valid and reliable method for assessing blood flow in the limb. Possible applications of EIT in localising fluid changes are discussed.

  12. Reliability of Leg and Vertical Stiffness During High Speed Treadmill Running.

    PubMed

    Pappas, Panagiotis; Dallas, Giorgos; Paradisis, Giorgos

    2017-04-01

    In research, the accurate and reliable measurement of leg and vertical stiffness could contribute to valid interpretations. The current study aimed at determining the intraparticipant variability (ie, intraday and interday reliabilities) of leg and vertical stiffness, as well as related parameters, during high speed treadmill running, using the "sine-wave" method. Thirty-one males ran on a treadmill at 6.67 m∙s -1 , and the contact and flight times were measured. To determine the intraday reliability, three 10-s running bouts with 10-min recovery were performed. In addition, to examine the interday reliability, three 10-s running bouts on 3 separate days with 48-h interbout intervals were performed. The reliability statistics included repeated-measure analysis of variance, average intertrial correlations, intraclass correlation coefficients (ICCs), Cronbach's α reliability coefficient, and the coefficient of variation (CV%). Both intraday and interday reliabilities were high for leg and vertical stiffness (ICC > 0.939 and CV < 4.3%), as well as related variables (ICC > 0.934 and CV < 3.9%). It was thus inferred that the measurements of leg and vertical stiffness, as well as the related parameters obtained using the "sine-wave" method during treadmill running at 6.67 m∙s -1 , were highly reliable, both within and across days.

  13. Assessing assay agreement estimation for multiple left-censored data: a multiple imputation approach.

    PubMed

    Lapidus, Nathanael; Chevret, Sylvie; Resche-Rigon, Matthieu

    2014-12-30

    Agreement between two assays is usually based on the concordance correlation coefficient (CCC), estimated from the means, standard deviations, and correlation coefficient of these assays. However, such data will often suffer from left-censoring because of lower limits of detection of these assays. To handle such data, we propose to extend a multiple imputation approach by chained equations (MICE) developed in a close setting of one left-censored assay. The performance of this two-step approach is compared with that of a previously published maximum likelihood estimation through a simulation study. Results show close estimates of the CCC by both methods, although the coverage is improved by our MICE proposal. An application to cytomegalovirus quantification data is provided. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Estimation of soil organic partition coefficients: from retention factors measured by soil column chromatography with water as eluent.

    PubMed

    Xu, Feng; Liang, Xinmiao; Lin, Bingcheng; Schramm, Karl-Werner; Kettrup, Antonius

    2002-08-30

    The retention factors (k) of 104 hydrophobic organic chemicals (HOCs) were measured in soil column chromatography (SCC) over columns filled with three naturally occurring reference soils and eluted with Milli-Q water. A novel method for the estimation of soil organic partition coefficient (Koc) was developed based on correlations with k in soil/water systems. Strong log Koc versus log k correlations (r>0.96) were found. The estimated Koc values were in accordance with the literature values with a maximum deviation of less than 0.4 log units. All estimated Koc values from three soils were consistent with each other. The SCC approach is promising for fast screening of a large number of chemicals in their environmental applications.

  15. Selectivity of similar compounds' identification using IR spectrometry: β-Lactam antibiotics

    NASA Astrophysics Data System (ADS)

    Sadlej-Sosnowska, Nina; Ocios, Agnieszka; Fuks, Leon

    2006-07-01

    The study aims to develop a reliable, quantitative method for positive identification or discrimination of a substance, when it is compared to a set of similar ones. In the course of the study a group of structurally related compounds, namely a set of β-lactam antimicrobial agents has been explored. Identification of a substance was based on the comparison of its spectrum with that of a reference material by using two functional algorithms. The algorithm based on the calculation of correlation coefficient between the first derivatives of the spectra has been proved more powerful than that using the original spectra. Then the results in a few spectral regions were likened. Limiting values were proposed for correlation coefficients that allow for qualification of a substance as identical to the reference one.

  16. Volumetric segmentation of ADC maps and utility of standard deviation as measure of tumor heterogeneity in soft tissue tumors.

    PubMed

    Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K

    2016-01-01

    Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Empirical analysis on future-cash arbitrage risk with portfolio VaR

    NASA Astrophysics Data System (ADS)

    Chen, Rongda; Li, Cong; Wang, Weijin; Wang, Ze

    2014-03-01

    This paper constructs the positive arbitrage position by alternating the spot index with Chinese Exchange Traded Fund (ETF) portfolio and estimating the arbitrage-free interval of futures with the latest trade data. Then, an improved Delta-normal method was used, which replaces the simple linear correlation coefficient with tail dependence correlation coefficient, to measure VaR (Value-at-risk) of the arbitrage position. Analysis of VaR implies that the risk of future-cash arbitrage is less than that of investing completely in either futures or spot market. Then according to the compositional VaR and the marginal VaR, we should increase the futures position and decrease the spot position appropriately to minimize the VaR, which can minimize risk subject to certain revenues.

  18. Rapid estimation of the electron correlation energy for van der Waals complexes RgX (Rg = Kr, Xe, X = Br, I)

    NASA Astrophysics Data System (ADS)

    Xinying, Li; Yongfang, Zhao; Xiaogong, Jing; Fengli, Liu; Fengyou, Hao

    2006-01-01

    We present the rules of electron correlation energies for RgX (Rg = Kr, Xe, X = Br, I) van der Waals (vdW) complex systems at CCSD(T) theoretical level with SDB-cc-pVQZ basis set by the Gaussian 98 program. A new method to derive the dispersion coefficient C6 by fitting the intermonomer electron correlation energies to C6R-6 function is introduced. The present C6 values are compared with the corresponding theoretical ones.

  19. Linear Least Squares for Correlated Data

    NASA Technical Reports Server (NTRS)

    Dean, Edwin B.

    1988-01-01

    Throughout the literature authors have consistently discussed the suspicion that regression results were less than satisfactory when the independent variables were correlated. Camm, Gulledge, and Womer, and Womer and Marcotte provide excellent applied examples of these concerns. Many authors have obtained partial solutions for this problem as discussed by Womer and Marcotte and Wonnacott and Wonnacott, which result in generalized least squares algorithms to solve restrictive cases. This paper presents a simple but relatively general multivariate method for obtaining linear least squares coefficients which are free of the statistical distortion created by correlated independent variables.

  20. Applications of interferometrically derived terrain slopes: Normalization of SAR backscatter and the interferometric correlation coefficient

    NASA Technical Reports Server (NTRS)

    Werner, Charles L.; Wegmueller, Urs; Small, David L.; Rosen, Paul A.

    1994-01-01

    Terrain slopes, which can be measured with Synthetic Aperture Radar (SAR) interferometry either from a height map or from the interferometric phase gradient, were used to calculate the local incidence angle and the correct pixel area. Both are required for correct thematic interpretation of SAR data. The interferometric correlation depends on the pixel area projected on a plane perpendicular to the look vector and requires correction for slope effects. Methods for normalization of the backscatter and interferometric correlation for ERS-1 SAR are presented.

Top