Sample records for method detection level

  1. New reporting procedures based on long-term method detection levels and some considerations for interpretations of water-quality data provided by the U.S. Geological Survey National Water Quality Laboratory

    USGS Publications Warehouse

    Childress, Carolyn J. Oblinger; Foreman, William T.; Connor, Brooke F.; Maloney, Thomas J.

    1999-01-01

    This report describes the U.S. Geological Survey National Water Quality Laboratory?s approach for determining long-term method detection levels and establishing reporting levels, details relevant new reporting conventions, and provides preliminary guidance on interpreting data reported with the new conventions. At the long-term method detection level concentration, the risk of a false positive detection (analyte reported present at the long-term method detection level when not in sample) is no more than 1 percent. However, at the long-term method detection level, the risk of a false negative occurrence (analyte reported not present when present at the long-term method detection level concentration) is up to 50 percent. Because this false negative rate is too high for use as a default 'less than' reporting level, a more reliable laboratory reporting level is set at twice the determined long-term method detection level. For all methods, concentrations measured between the laboratory reporting level and the long-term method detection level will be reported as estimated concentrations. Non-detections will be censored to the laboratory reporting level. Adoption of the new reporting conventions requires a full understanding of how low-concentration data can be used and interpreted and places responsibility for using and presenting final data with the user rather than with the laboratory. Users must consider that (1) new laboratory reporting levels may differ from previously established minimum reporting levels, (2) long-term method detection levels and laboratory reporting levels may change over time, and (3) estimated concentrations are less certain than concentrations reported above the laboratory reporting level. The availability of uncensored but qualified low-concentration data for interpretation and statistical analysis is a substantial benefit to the user. A decision to censor data after they are reported from the laboratory may still be made by the user, if merited, on the basis of the intended use of the data.

  2. Assessment of Hyporheic Zone, Flood-Plain, Soil-Gas, Soil, and Surface-Water Contamination at the McCoys Creek Chemical Training Area, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, Georgia, assessed the hyporheic zone, flood plain, soil gas, soil, and surface water for contaminants at the McCoys Creek Chemical Training Area (MCTA) at Fort Gordon, from October 2009 to September 2010. The assessment included the detection of organic contaminants in the hyporheic zone, flood plain, soil gas, and surface water. In addition, the organic contaminant assessment included the analysis of organic compounds classified as explosives and chemical agents in selected areas. Inorganic contaminants were assessed in soil and surface-water samples. The assessment was conducted to provide environmental contamination data to the U.S. Army at Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Ten passive samplers were deployed in the hyporheic zone and flood plain, and total petroleum hydrocarbons (TPH) and octane were detected above the method detection level in every sampler. Other organic compounds detected above the method detection level in the hyporheic zone and flood-plain samplers were trichloroethylene, and cis- and trans- 1, 2-dichloroethylene. One trip blank detected TPH below the method detection level but above the nondetection level. The concentrations of TPH in the samplers were many times greater than the concentrations detected in the blank; therefore, all other TPH concentrations detected are considered to represent environmental conditions. Seventy-one soil-gas samplers were deployed in a grid pattern across the MCTA. Three trip blanks and three method blanks were used and not deployed, and TPH was detected above the method detection level in two trip blanks and one method blank. Detection of TPH was observed at all 71 samplers, but because TPH was detected in the trip and method blanks, TPH was censored and, therefore, only 7 of the 71 samplers were reported as detecting TPH. In addition, benzene, toluene, ethylbenzene, and total xylene were detected above the method detection level in 22 samplers. Other compounds detected above the method detection level included naphthalene, octane, undecane, tridecane, 1,2,4-trimethylbenzene, trichloroethylene, perchloroethylene, chloroform, and 1,4-dichlorobenzene. Subsequent to the soil-gas survey, five locations with elevated contaminant mass were selected and a passive sampler was deployed at those locations to detect the presence of organic compounds classified as explosives or chemical agents. No explosives or chemical agents were detected above the method detection level, but some compounds were detected below the method detection level but above the nondetection level. Dimethyl disulfide, benzothiazole, chloroacetophenones, and para-chlorophenyl methyl sulfide were all detected below the method detection level but above the nondetection level. The compounds 2,4-dinitrotoluene, and para-chlorophenyl methyl sulfone were detected in samplers but also were detected in trip blanks and are not considered as present in the MCTA. The same five locations that were selected for sampling of explosives and chemical agents were selected for soil sampling. Metal concentrations in composite soil samples collected at five locations from land surface to a depth of 6 inches did not exceed the U.S. Environmental Protection Agency Regional Screening Levels for Industrial Soil. Concentrations in some compounds were higher than the South Carolina Department of Health and Environmental Control background levels for nearby South Carolina, including aluminum, arsenic, barium, beryllium, chromium, copper, iron, lead, manganese, nickel, and potassium. A surface-water sample was collected from McCoys Creek and analyzed for volatile organic compounds, semivolatile organic compounds, and inorganic compounds (metals). No volatile organic compounds and (or) semivolatile organic compounds were detected at levels above the maximum contaminant level of the U.S. Environmental Protection Agency (USEPA) National Primary Drinking Water Standard, and no inorganic compounds exceeded the maximum contaminant level of the USEPA National Primary Drinking Water Standard or the Georgia In-Stream Water-Quality Standard. Iron was the only inorganic compound detected in the surface-water sample (578 micrograms per liter) that exceeded the USEPA National Secondary Drinking Water Standard of 300 micrograms per liter.

  3. A coloured oil level indicator detection method based on simple linear iterative clustering

    NASA Astrophysics Data System (ADS)

    Liu, Tianli; Li, Dongsong; Jiao, Zhiming; Liang, Tao; Zhou, Hao; Yang, Guoqing

    2017-12-01

    A detection method of coloured oil level indicator is put forward. The method is applied to inspection robot in substation, which realized the automatic inspection and recognition of oil level indicator. Firstly, the detected image of the oil level indicator is collected, and the detected image is clustered and segmented to obtain the label matrix of the image. Secondly, the detection image is processed by colour space transformation, and the feature matrix of the image is obtained. Finally, the label matrix and feature matrix are used to locate and segment the detected image, and the upper edge of the recognized region is obtained. If the upper limb line exceeds the preset oil level threshold, the alarm will alert the station staff. Through the above-mentioned image processing, the inspection robot can independently recognize the oil level of the oil level indicator, and instead of manual inspection. It embodies the automatic and intelligent level of unattended operation.

  4. How do we know if plants in our nursery have Phytophthora? Detection methods and an integrated approach to monitoring

    Treesearch

    Christa Conforti

    2017-01-01

    A Phytophthora cactorum-infected nursery crop of Ceanothus thyrsiflorus was used to evaluate three Phytophthora monitoring methods. The Phytophthora detection level of three non-destructive sampling methods was quantified and compared to the detection level of destructive sampling. Non-...

  5. Automatic QRS complex detection using two-level convolutional neural network.

    PubMed

    Xiang, Yande; Lin, Zhitao; Meng, Jianyi

    2018-01-29

    The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especially in the transform domains. In addition, fixed features and parameters are not suitable for detecting various kinds of QRS complexes under different circumstances. In this study, based on 1-D convolutional neural network (CNN), an accurate method for QRS complex detection is proposed. The CNN consists of object-level and part-level CNNs for extracting different grained ECG morphological features automatically. All the extracted morphological features are used by multi-layer perceptron (MLP) for QRS complex detection. Additionally, a simple ECG signal preprocessing technique which only contains difference operation in temporal domain is adopted. Based on the MIT-BIH arrhythmia (MIT-BIH-AR) database, the proposed detection method achieves overall sensitivity Sen = 99.77%, positive predictivity rate PPR = 99.91%, and detection error rate DER = 0.32%. In addition, the performance variation is performed according to different signal-to-noise ratio (SNR) values. An automatic QRS detection method using two-level 1-D CNN and simple signal preprocessing technique is proposed for QRS complex detection. Compared with the state-of-the-art QRS complex detection approaches, experimental results show that the proposed method acquires comparable accuracy.

  6. Evaluation of 3M™ Molecular Detection Assay (MDA) Listeria for the Detection of Listeria species in Selected Foods and Environmental Surfaces: Collaborative Study, First Action 2014.06.

    PubMed

    Bird, Patrick; Flannery, Jonathan; Crowley, Erin; Agin, James; Goins, David; Monteroso, Lisa; Benesh, DeAnn

    2015-01-01

    The 3M™ Molecular Detection Assay (MDA) Listeria is used with the 3M Molecular Detection System for the detection of Listeria species in food, food-related, and environmental samples after enrichment. The assay utilizes loop-mediated isothermal amplification to rapidly amplify Listeria target DNA with high specificity and sensitivity, combined with bioluminescence to detect the amplification. The 3M MDA Listeria method was evaluated using an unpaired study design in a multilaboratory collaborative study and compared to the AOAC Official Method of AnalysisSM (OMA) 993.12 Listeria monocytogenes in Milk and Dairy Products reference method for the detection of Listeria species in full-fat (4% milk fat) cottage cheese (25 g test portions). A total of 15 laboratories located in the continental United States and Canada participated. Each matrix had three inoculation levels: an uninoculated control level (0 CFU/test portion), and two levels artificially contaminated with Listeria monocytogenes, a low inoculum level (0.2-2 CFU/test portion) and a high inoculum level (2-5 CFU/test portion) using nonheat-stressed cells. In total, 792 unpaired replicate portions were analyzed. Statistical analysis was conducted according to the probability of detection (POD) model. Results obtained for the low inoculum level test portions produced a difference in cross-laboratory POD value of -0.07 with a 95% confidence interval of (-0.19, 0.06). No statistically significant differences were observed in the number of positive samples detected by the 3M MDA Listeria method versus the AOAC OMA method.

  7. Hybrid approach for detection of dental caries based on the methods FCM and level sets

    NASA Astrophysics Data System (ADS)

    Chaabene, Marwa; Ben Ali, Ramzi; Ejbali, Ridha; Zaied, Mourad

    2017-03-01

    This paper presents a new technique for detection of dental caries that is a bacterial disease that destroys the tooth structure. In our approach, we have achieved a new segmentation method that combines the advantages of fuzzy C mean algorithm and level set method. The results obtained by the FCM algorithm will be used by Level sets algorithm to reduce the influence of the noise effect on the working of each of these algorithms, to facilitate level sets manipulation and to lead to more robust segmentation. The sensitivity and specificity confirm the effectiveness of proposed method for caries detection.

  8. Assessment of soil-gas contamination at building 310 underground storage tank area, Fort Gordon, Georgia, 2010-2011

    USGS Publications Warehouse

    Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2012-01-01

    Soil gas was assessed for contaminants in the building 310 underground storage tank area adjacent to the Dwight D. Eisenhower Army Medical Center at Ft. Gordon, Georgia, from October 2010 to September 2011. The assessment, which also included the detection of organic compounds in soil gas, provides environmental contamination data to Fort Gordon personnel pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The study was conducted by the U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon. Soil-gas samplers were deployed below land surface at 37 locations in the building 310 underground storage tank area. Soil-gas samplers were deployed in a grid pattern near the storage tank area as well as downslope of the tank area in the direction of groundwater flow toward an unnamed tributary to Butler Creek. Total petroleum hydrocarbons were detected in 35 of the 37 soil-gas samplers at levels above the method detection level, and the combined mass of benzene, toluene, ethylbenzene, and total xylenes were detected above their detection levels in 8 of the 37 samplers. In addition, the combined masses of undecane, tridecane, and pentadecane were detected at or above their method detection levels in 9 of the 37 samplers. Other volatile organic compounds detected above their respective method detection levels were chloroform, 1,2,4-trimethylbenzene, and perchloroethylene. In addition, naphthalene, 2-methyl naphthalene, and 1,2,4-trimethylbenzene were detected below the method detection levels, but above the nondetection level.

  9. System and Method for Multi-Wavelength Optical Signal Detection

    NASA Technical Reports Server (NTRS)

    McGlone, Thomas D. (Inventor)

    2017-01-01

    The system and method for multi-wavelength optical signal detection enables the detection of optical signal levels significantly below those processed at the discrete circuit level by the use of mixed-signal processing methods implemented with integrated circuit technologies. The present invention is configured to detect and process small signals, which enables the reduction of the optical power required to stimulate detection networks, and lowers the required laser power to make specific measurements. The present invention provides an adaptation of active pixel networks combined with mixed-signal processing methods to provide an integer representation of the received signal as an output. The present invention also provides multi-wavelength laser detection circuits for use in various systems, such as a differential absorption light detection and ranging system.

  10. Simultaneous Detection of Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes at a Very Low Level Using Simultaneous Enrichment Broth and Multichannel SPR Biosensor.

    PubMed

    Zhang, Xiaoguang; Tsuji, Sachiko; Kitaoka, Hayato; Kobayashi, Hiroshi; Tamai, Mitsuru; Honjoh, Ken-Ichi; Miyamoto, Takahisa

    2017-10-01

    Detection of foodborne pathogens at very low levels is still a challenge. A custom-built multichannel surface plasmon resonance (SPR) biosensor and simultaneous enrichment broth (SEB) were used to develop a simultaneous detection method for 3 important foodborne pathogens, Escherichia coli O157:H7 (O157:H7), Salmonella enteritidis, and Listeria monocytogenes, at a very low level. These 3 foodborne pathogens at a very low level (14, 6, and 28 CFU/25 g (mL) for O157:H7, S. enteritidis, and L. monocytogenes, respectively) were inoculated in SEB and incubated at 37 ˚C for 24 h. Sample prepared from the simultaneous enrichment culture was analyzed using the multichannel SPR biosensor and sensor chip immobilized with polyclonal antibodies specific to each of the target pathogens. O157:H7, S. enteritidis, and L. monocytogenes in chicken were detected simultaneously at an inoculum dose of 14, 6, and 28 CFU/25 g, respectively. Our method using a custom-built multichannel SPR biosensor and enrichment in SEB is expected as a rapid and simultaneous detection method for low levels of O157:H7, S. enteritidis, and L. monocytogenes in food. Our method is expected as a rapid and simultaneous detection method for pathogens at very low levels. It has great potential for safety control of food and microbiological detection applications. © 2017 Institute of Food Technologists®.

  11. An improved AE detection method of rail defect based on multi-level ANC with VSS-LMS

    NASA Astrophysics Data System (ADS)

    Zhang, Xin; Cui, Yiming; Wang, Yan; Sun, Mingjian; Hu, Hengshan

    2018-01-01

    In order to ensure the safety and reliability of railway system, Acoustic Emission (AE) method is employed to investigate rail defect detection. However, little attention has been paid to the defect detection at high speed, especially for noise interference suppression. Based on AE technology, this paper presents an improved rail defect detection method by multi-level ANC with VSS-LMS. Multi-level noise cancellation based on SANC and ANC is utilized to eliminate complex noises at high speed, and tongue-shaped curve with index adjustment factor is proposed to enhance the performance of variable step-size algorithm. Defect signals and reference signals are acquired by the rail-wheel test rig. The features of noise signals and defect signals are analyzed for effective detection. The effectiveness of the proposed method is demonstrated by comparing with the previous study, and different filter lengths are investigated to obtain a better noise suppression performance. Meanwhile, the detection ability of the proposed method is verified at the top speed of the test rig. The results clearly illustrate that the proposed method is effective in detecting rail defects at high speed, especially for noise interference suppression.

  12. A spatial scan statistic for nonisotropic two-level risk cluster.

    PubMed

    Li, Xiao-Zhou; Wang, Jin-Feng; Yang, Wei-Zhong; Li, Zhong-Jie; Lai, Sheng-Jie

    2012-01-30

    Spatial scan statistic methods are commonly used for geographical disease surveillance and cluster detection. The standard spatial scan statistic does not model any variability in the underlying risks of subregions belonging to a detected cluster. For a multilevel risk cluster, the isotonic spatial scan statistic could model a centralized high-risk kernel in the cluster. Because variations in disease risks are anisotropic owing to different social, economical, or transport factors, the real high-risk kernel will not necessarily take the central place in a whole cluster area. We propose a spatial scan statistic for a nonisotropic two-level risk cluster, which could be used to detect a whole cluster and a noncentralized high-risk kernel within the cluster simultaneously. The performance of the three methods was evaluated through an intensive simulation study. Our proposed nonisotropic two-level method showed better power and geographical precision with two-level risk cluster scenarios, especially for a noncentralized high-risk kernel. Our proposed method is illustrated using the hand-foot-mouth disease data in Pingdu City, Shandong, China in May 2009, compared with two other methods. In this practical study, the nonisotropic two-level method is the only way to precisely detect a high-risk area in a detected whole cluster. Copyright © 2011 John Wiley & Sons, Ltd.

  13. Ultraviolet resonance Raman spectroscopy for the detection of cocaine in oral fluid

    NASA Astrophysics Data System (ADS)

    D'Elia, Valentina; Montalvo, Gemma; Ruiz, Carmen García; Ermolenkov, Vladimir V.; Ahmed, Yasmine; Lednev, Igor K.

    2018-01-01

    Detecting and quantifying cocaine in oral fluid is of significant importance for practical forensics. Up to date, mainly destructive methods or biochemical tests have been used, while spectroscopic methods were only applied to pretreated samples. In this work, the possibility of using resonance Raman spectroscopy to detect cocaine in oral fluid without pretreating samples was tested. It was found that ultraviolet resonance Raman spectroscopy with 239-nm excitation allows for the detection of cocaine in oral fluid at 10 μg/mL level. Further method development will be needed for reaching the practically useful levels of cocaine detection.

  14. Method for detection of antibodies for metallic elements

    DOEpatents

    Barrick, C.W.; Clarke, S.M.; Nordin, C.W.

    1993-11-30

    An apparatus and method for detecting antibodies specific to non-protein antigens. The apparatus is an immunological plate containing a plurality of plastic projections coated with a non-protein material. Assays utilizing the plate are capable of stabilizing the non-protein antigens with detection levels for antibodies specific to the antigens on a nanogram level. A screening assay with the apparatus allows for early detection of exposure to non-protein materials. Specifically metallic elements are detected. 10 figures.

  15. Assessment of groundwater, soil-gas, and soil contamination at the Vietnam Armor Training Facility, Fort Gordon, Georgia, 2009-2011

    USGS Publications Warehouse

    Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2012-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, Georgia, assessed the groundwater, soil gas, and soil for contaminants at the Vietnam Armor Training Facility (VATF) at Fort Gordon, from October 2009 to September 2011. The assessment included the detection of organic compounds in the groundwater and soil gas, and inorganic compounds in the soil. In addition, organic contaminant assessment included organic compounds classified as explosives and chemical agents in selected areas. The assessment was conducted to provide environmental contamination data to the U.S. Army at Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. This report is a revision of "Assessment of soil-gas, surface-water, and soil contamination at the Vietnam Armor Training Facility, Fort Gordon, Georgia, 2009-2010," Open-File Report 2011-1200, and supersedes that report to include results of additional samples collected in July 2011. Four passive samplers were deployed in groundwater wells at the VATF in Fort Gordon. Total petroleum hydrocarbons and benzene and octane were detected above the method detection level at all four wells. The only other volatile organic compounds detected above their method detection level were undecane and pentadecane, which were detected in two of the four wells. Soil-gas samplers were deployed at 72 locations in a grid pattern across the VATF on June 3, 2010, and then later retrieved on June 9, 2010. Total petroleum hydrocarbons were detected in 71 of the 72 samplers (one sampler was destroyed in the field and not analyzed) at levels above the method detection level, and the combined mass of benzene, toluene, ethylbenzene, and total xylene (BTEX) was detected above the detection level in 31 of the 71 samplers that were analyzed. Other volatile organic compounds detected above their respective method detection levels were naphthalene, 2-methyl-naphthalene, tridecane, 1,2,4-trimethylbenzene, and perchloroethylene. After the results of the 71 soil-gas samplers were received, 31 additional passive soil-gas samplers were deployed on July 14, 2011, and retrieved on July 18, 2011. These 31 samplers were deployed on a larger areal scale to better define the extent of the contamination. Total petroleum hydrocarbons were detected above their method detection level at all 31 samplers, whereas BTEX was detected above its method detection level at 17 of the 31 samplers. Other organic compounds detected above their method detection levels were naphthalene, 2-methyl-naphthalene, octane, undecane, tridecane, pentadecane, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene, chloroform, and perchloroethylene. Subsequent to the 2010 soil-gas survey, four areas determined to have elevated contaminant mass were selected and sampled for explosives and chemical agents. No detections of explosives or chemical agents above their respective method detection levels were found at any of the sampling locations. The same four locations that were sampled for explosives and chemical agents were selected for the collection of soil samples. A fifth location also was selected on the basis of the elevated contaminant mass of the soil-gas survey. No metals that exceeded the Regional Screening Levels for Industrial Soils, as classified by the U.S. Environmental Protection Agency, were detected at any of the five VATF locations. The soil samples also were compared to values from the ambient, uncontaminated (background) levels for soils in South Carolina, as classified by the South Carolina Department of Health and Environmental Control. Because South Carolina is adjacent to Georgia and the soils in the Coastal Plain are similar, these comparisons are valid. No similar values are available for Georgia to use for comparison purposes. The metals that were detected above the ambient background levels for South Carolina, as classified by the South Carolina Department of Health and Environmental Control, include aluminum, arsenic, barium, beryllium, calcium, chromium, copper, iron, lead, magnesium, manganese, nickel, potassium, sodium, and zinc.

  16. Thermal detection thresholds in 5-year-old preterm born children; IQ does matter.

    PubMed

    de Graaf, Joke; Valkenburg, Abraham J; Tibboel, Dick; van Dijk, Monique

    2012-07-01

    Experiencing pain at newborn age may have consequences on one's somatosensory perception later in life. Children's perception for cold and warm stimuli may be determined with the Thermal Sensory Analyzer (TSA) device by two different methods. This pilot study in 5-year-old children born preterm aimed at establishing whether the TSA method of limits, which is dependent of reaction time, and the method of levels, which is independent of reaction time, would yield different cold and warm detection thresholds. The second aim was to establish possible associations between intellectual ability and the detection thresholds obtained with either method. A convenience sample was drawn from the participants in an ongoing 5-year follow-up study of a randomized controlled trial on effects of morphine during mechanical ventilation. Thresholds were assessed using both methods and statistically compared. Possible associations between the child's intelligence quotient (IQ) and threshold levels were analyzed. The method of levels yielded more sensitive thresholds than did the method of limits, i.e. mean (SD) cold detection thresholds: 30.3 (1.4) versus 28.4 (1.7) (Cohen'sd=1.2, P=0.001) and warm detection thresholds; 33.9 (1.9) versus 35.6 (2.1) (Cohen's d=0.8, P=0.04). IQ was statistically significantly associated only with the detection thresholds obtained with the method of limits (cold: r=0.64, warm: r=-0.52). The TSA method of levels, is to be preferred over the method of limits in 5-year-old preterm born children, as it establishes more sensitive detection thresholds and is independent of IQ. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Multi person detection and tracking based on hierarchical level-set method

    NASA Astrophysics Data System (ADS)

    Khraief, Chadia; Benzarti, Faouzi; Amiri, Hamid

    2018-04-01

    In this paper, we propose an efficient unsupervised method for mutli-person tracking based on hierarchical level-set approach. The proposed method uses both edge and region information in order to effectively detect objects. The persons are tracked on each frame of the sequence by minimizing an energy functional that combines color, texture and shape information. These features are enrolled in covariance matrix as region descriptor. The present method is fully automated without the need to manually specify the initial contour of Level-set. It is based on combined person detection and background subtraction methods. The edge-based is employed to maintain a stable evolution, guide the segmentation towards apparent boundaries and inhibit regions fusion. The computational cost of level-set is reduced by using narrow band technique. Many experimental results are performed on challenging video sequences and show the effectiveness of the proposed method.

  18. Thin layer chromatographic method for the detection of uric acid: collaborative study.

    PubMed

    Thrasher, J J; Abadie, A

    1978-07-01

    A collaborative study has been completed on an improved method for the detection and confirmation of uric acid from bird and insect excreta. The proposed method involves the lithium carbonate solubilization of the suspect excreta material, followed by butanol-methanol-water-acetic acid thin layer chromatography, and trisodium phosphate-phosphotungstic acid color development. The collaborative tests resulted in 100% detection of uric acid standard at the 50 ng level and 75% detection at the 20-25 ng level. No false positives were reported during tests of compounds similar to uric acid. The proposed method has been adopted official first action; the present official final action method, 44.161, will be retained for screening purposes.

  19. [Quality control assessments of feces examination for schistosomiasis in province-level laboratories of Zhejiang Province].

    PubMed

    Chen, Wen; Zhu, Ming-Dong; Yan, Xiao-Lan; Lin, Li-Jun; Zhang, Jian-Feng; Li, Li; Wen, Li-Yong

    2011-06-01

    To understand and evaluate the quality of feces examination for schistosomiasis in province-level laboratories of Zhejiang Province. With the single-blind method, the stool samples were detected by the stool hatching method and sediment detection method. In the 3 quality control assessments in 2006, 2008 and 2009, most laboratories finished the examinations on time. The accordance rates of detections were 88.9%, 100% and 93.9%, respectively. The province-level laboratories for schistosomiasis feces examination of Zhejiang Province is coming into standardization, and the techniques of schistosomiasis feces examination are optimized gradually.

  20. SuBSENSE: a universal change detection method with local adaptive sensitivity.

    PubMed

    St-Charles, Pierre-Luc; Bilodeau, Guillaume-Alexandre; Bergevin, Robert

    2015-01-01

    Foreground/background segmentation via change detection in video sequences is often used as a stepping stone in high-level analytics and applications. Despite the wide variety of methods that have been proposed for this problem, none has been able to fully address the complex nature of dynamic scenes in real surveillance tasks. In this paper, we present a universal pixel-level segmentation method that relies on spatiotemporal binary features as well as color information to detect changes. This allows camouflaged foreground objects to be detected more easily while most illumination variations are ignored. Besides, instead of using manually set, frame-wide constants to dictate model sensitivity and adaptation speed, we use pixel-level feedback loops to dynamically adjust our method's internal parameters without user intervention. These adjustments are based on the continuous monitoring of model fidelity and local segmentation noise levels. This new approach enables us to outperform all 32 previously tested state-of-the-art methods on the 2012 and 2014 versions of the ChangeDetection.net dataset in terms of overall F-Measure. The use of local binary image descriptors for pixel-level modeling also facilitates high-speed parallel implementations: our own version, which used no low-level or architecture-specific instruction, reached real-time processing speed on a midlevel desktop CPU. A complete C++ implementation based on OpenCV is available online.

  1. An interlaboratory study on efficient detection of Shiga toxin-producing Escherichia coli O26, O103, O111, O121, O145, and O157 in food using real-time PCR assay and chromogenic agar.

    PubMed

    Hara-Kudo, Yukiko; Konishi, Noriko; Ohtsuka, Kayoko; Iwabuchi, Kaori; Kikuchi, Rie; Isobe, Junko; Yamazaki, Takumiko; Suzuki, Fumie; Nagai, Yuhki; Yamada, Hiroko; Tanouchi, Atsuko; Mori, Tetsuya; Nakagawa, Hiroshi; Ueda, Yasufumi; Terajima, Jun

    2016-08-02

    To establish an efficient detection method for Shiga toxin (Stx)-producing Escherichia coli (STEC) O26, O103, O111, O121, O145, and O157 in food, an interlaboratory study using all the serogroups of detection targets was firstly conducted. We employed a series of tests including enrichment, real-time PCR assays, and concentration by immunomagnetic separation, followed by plating onto selective agar media (IMS-plating methods). This study was particularly focused on the efficiencies of real-time PCR assays in detecting stx and O-antigen genes of the six serogroups and of IMS-plating methods onto selective agar media including chromogenic agar. Ground beef and radish sprouts samples were inoculated with the six STEC serogroups either at 4-6CFU/25g (low levels) or at 22-29CFU/25g (high levels). The sensitivity of stx detection in ground beef at both levels of inoculation with all six STEC serogroups was 100%. The sensitivity of stx detection was also 100% in radish sprouts at high levels of inoculation with all six STEC serogroups, and 66.7%-91.7% at low levels of inoculation. The sensitivity of detection of O-antigen genes was 100% in both ground beef and radish sprouts at high inoculation levels, while at low inoculation levels, it was 95.8%-100% in ground beef and 66.7%-91.7% in radish sprouts. The sensitivity of detection with IMS-plating was either the same or lower than those of the real-time PCR assays targeting stx and O-antigen genes. The relationship between the results of IMS-plating methods and Ct values of real-time PCR assays were firstly analyzed in detail. Ct values in most samples that tested negative in the IMS-plating method were higher than the maximum Ct values in samples that tested positive in the IMS-plating method. This study indicates that all six STEC serogroups in food contaminated with more than 29CFU/25g were detected by real-time PCR assays targeting stx and O-antigen genes and IMS-plating onto selective agar media. Therefore, screening of stx and O-antigen genes followed by isolation of STECs by IMS-plating methods may be an efficient method to detect the six STEC serogroups. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Man vs. Machine: A Junior-level Laboratory Exercise Comparing Human and Instrumental Detection Limits

    ERIC Educational Resources Information Center

    Elias, Ryan J.; Hopfer, Helene; Hofstaedter, Amanda N.; Hayes, John E.

    2017-01-01

    The human nose is a very sensitive detector and is able to detect potent aroma compounds down to low ng/L levels. These levels are often below detection limits of analytical instrumentation. The following laboratory exercise is designed to compare instrumental and human methods for the detection of volatile odor active compounds. Reference…

  3. Evaluating the performance of the quick CSF method in detecting contrast sensitivity function changes

    PubMed Central

    Hou, Fang; Lesmes, Luis Andres; Kim, Woojae; Gu, Hairong; Pitt, Mark A.; Myung, Jay I.; Lu, Zhong-Lin

    2016-01-01

    The contrast sensitivity function (CSF) has shown promise as a functional vision endpoint for monitoring the changes in functional vision that accompany eye disease or its treatment. However, detecting CSF changes with precision and efficiency at both the individual and group levels is very challenging. By exploiting the Bayesian foundation of the quick CSF method (Lesmes, Lu, Baek, & Albright, 2010), we developed and evaluated metrics for detecting CSF changes at both the individual and group levels. A 10-letter identification task was used to assess the systematic changes in the CSF measured in three luminance conditions in 112 naïve normal observers. The data from the large sample allowed us to estimate the test–retest reliability of the quick CSF procedure and evaluate its performance in detecting CSF changes at both the individual and group levels. The test–retest reliability reached 0.974 with 50 trials. In 50 trials, the quick CSF method can detect a medium 0.30 log unit area under log CSF change with 94.0% accuracy at the individual observer level. At the group level, a power analysis based on the empirical distribution of CSF changes from the large sample showed that a very small area under log CSF change (0.025 log unit) could be detected by the quick CSF method with 112 observers and 50 trials. These results make it plausible to apply the method to monitor the progression of visual diseases or treatment effects on individual patients and greatly reduce the time, sample size, and costs in clinical trials at the group level. PMID:27120074

  4. Assessment of hyporheic zone, flood-plain, soil-gas, soil, and surface-water contamination at the Old Incinerator Area, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, Georgia, assessed the hyporheic zone, flood plain, soil gas, soil, and surface-water for contaminants at the Old Incinerator Area at Fort Gordon, from October 2009 to September 2010. The assessment included the detection of organic contaminants in the hyporheic zone, flood plain, soil gas, and surface water. In addition, the organic contaminant assessment included the analysis of explosives and chemical agents in selected areas. Inorganic contaminants were assessed in soil and surface-water samples. The assessment was conducted to provide environmental contamination data to the U.S. Army at Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Total petroleum hydrocarbons were detected above the method detection level in all 13 samplers deployed in the hyporheic zone and flood plain of an unnamed tributary to Spirit Creek. The combined concentrations of benzene, toluene, ethylbenzene, and total xylene were detected at 3 of the 13 samplers. Other organic compounds detected in one sampler included octane and trichloroethylene. In the passive soil-gas survey, 28 of the 60 samplers detected total petroleum hydrocarbons above the method detection level. Additionally, 11 of the 60 samplers detected the combined masses of benzene, toluene, ethylbenzene, and total xylene above the method detection level. Other compounds detected above the method detection level in the passive soil-gas survey included octane, trimethylbenzene, perchlorethylene, and chloroform. Subsequent to the passive soil-gas survey, six areas determined to have relatively high contaminant mass were selected, and soil-gas samplers were deployed, collected, and analyzed for explosives and chemical agents. No explosives or chemical agents were detected above their method detection levels, but those that were detected were above the nondetection level. The same six locations that were sampled for explosives and chemical agents were selected for the collection of soil samples. No metals that exceeded the Regional Screening Levels for Industrial Soils as classified by the U.S. Environmental Protection Agency were detected at any of the six Old Incinerator Area locations. The soil samples also were compared to values from the ambient, uncontaminated (background) levels for soils in South Carolina. Because South Carolina is adjacent to Georgia and the soils in the coastal plain are similar, these comparisons are valid. No similar values are available for Georgia to use for comparison purposes. The only metal detected above the ambient background levels for South Carolina was barium. A surface-water sample collected from a tributary west and north of the Old Incinerator Area was analyzed for volatile organic compounds, semivolatile organic compounds, and inorganic compounds (metals). The only volatile organic and (or) semivolatile organic compound that was detected above the laboratory reporting level was toluene. The compounds 4-isopropyl-1-methylbenzene and isophorone were detected above the nondetection level but below the laboratory reporting level and were estimated. These compounds were detected at levels below the maximum contaminant levels set by the U.S. Environmental Protection Agency National Primary Drinking Water Standard. Iron was the only inorganic compound detected in the surface-water sample that exceeded the maximum contaminant level set by the U.S. Environmental Protection Agency National Secondary Drinking Water Standard. No other inorganic compounds exceeded the maximum contaminant levels for the U.S. Environmental Protection Agency National Primary Drinking Water Standard, National Secondary Drinking Water Standard, or the Georgia In-Stream Water Quality Standard.

  5. Evaluation of 3M molecular detection assay (MDA) Salmonella for the detection of Salmonella in selected foods: collaborative study.

    PubMed

    Bird, Patrick; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Benzinger, M Joseph; Bedinghaus, Paige; Flannery, Jonathan; Crowley, Erin; Agin, James; Goins, David; Benesh, DeAnn; David, John

    2013-01-01

    The 3M Molecular Detection Assay (MDA) Salmonella is used with the 3M Molecular Detection System for the detection of Salmonella spp. in food, food-related, and environmental samples after enrichment. The assay utilizes loop-mediated isothermal amplification to rapidly amplify Salmonella target DNA with high specificity and sensitivity, combined with bioluminescence to detect the amplification. The 3M MDA Salmonella method was compared using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG 4.05), Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products for raw ground beef and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference method for wet dog food following the current AOAC guidelines. A total of 20 laboratories participated. For the 3M MDA Salmonella method, raw ground beef was analyzed using 25 g test portions, and wet dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each matrix were analyzed. Each matrix was artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1512 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD). For the low-level raw ground beef test portions, the following dLPOD (difference between the POD of the reference and candidate method) values with 95% confidence intervals were obtained: -0.01 (-0.14, +0.12). For the low-level wet dog food test portions, the following dLPOD with 95% confidence intervals were obtained: -0.04 (-0.16, +0.09). No significant differences were observed in the number of positive samples detected by the 3M MDA Salmonella method versus either the USDA/FSIS-MLG or FDA/BAM methods.

  6. Modeling panel detection frequencies by queuing system theory: an application in gas chromatography olfactometry.

    PubMed

    Bult, Johannes H F; van Putten, Bram; Schifferstein, Hendrik N J; Roozen, Jacques P; Voragen, Alphons G J; Kroeze, Jan H A

    2004-10-01

    In continuous vigilance tasks, the number of coincident panel responses to stimuli provides an index of stimulus detectability. To determine whether this number is due to chance, panel noise levels have been approximated by the maximum coincidence level obtained in stimulus-free conditions. This study proposes an alternative method by which to assess noise levels, derived from queuing system theory (QST). Instead of critical coincidence levels, QST modeling estimates the duration of coinciding responses in the absence of stimuli. The proposed method has the advantage over previous approaches that it yields more reliable noise estimates and allows for statistical testing. The method was applied in an olfactory detection experiment using 16 panelists in stimulus-present and stimulus-free conditions. We propose that QST may be used as an alternative to signal detection theory for analyzing data from continuous vigilance tasks.

  7. Method and apparatus for simultaneous detection and measurement of charged particles at one or more levels of particle flux for analysis of same

    DOEpatents

    Denton, M Bonner [Tucson, AZ; Sperline, Roger , Koppenaal, David W. , Barinaga, Charles J. , Hieftje, Gary , Barnes, IV, James H.; Atlas, Eugene [Irvine, CA

    2009-03-03

    A charged particle detector and method are disclosed providing for simultaneous detection and measurement of charged particles at one or more levels of particle flux in a measurement cycle. The detector provides multiple and independently selectable levels of integration and/or gain in a fully addressable readout manner.

  8. Approaching the Limit in Atomic Spectrochemical Analysis.

    ERIC Educational Resources Information Center

    Hieftje, Gary M.

    1982-01-01

    To assess the ability of current analytical methods to approach the single-atom detection level, theoretical and experimentally determined detection levels are presented for several chemical elements. A comparison of these methods shows that the most sensitive atomic spectrochemical technique currently available is based on emission from…

  9. Computer-aided detection of initial polyp candidates with level set-based adaptive convolution

    NASA Astrophysics Data System (ADS)

    Zhu, Hongbin; Duan, Chaijie; Liang, Zhengrong

    2009-02-01

    In order to eliminate or weaken the interference between different topological structures on the colon wall, adaptive and normalized convolution methods were used to compute the first and second order spatial derivatives of computed tomographic colonography images, which is the beginning of various geometric analyses. However, the performance of such methods greatly depends on the single-layer representation of the colon wall, which is called the starting layer (SL) in the following text. In this paper, we introduce a level set-based adaptive convolution (LSAC) method to compute the spatial derivatives, in which the level set method is employed to determine a more reasonable SL. The LSAC was applied to a computer-aided detection (CAD) scheme to detect the initial polyp candidates, and experiments showed that it benefits the CAD scheme in both the detection sensitivity and specificity as compared to our previous work.

  10. A system for measuring thermal activation energy levels in silicon by thermally stimulated capacitance

    NASA Technical Reports Server (NTRS)

    Cockrum, R. H.

    1982-01-01

    One method being used to determine energy level(s) and electrical activity of impurities in silicon is described. The method is called capacitance transient spectroscopy (CTS). It can be classified into three basic categories: the thermally stimulated capacitance method, the voltage-stimulated capacitance method, and the light-stimulated capacitance method; the first two categories are discussed. From the total change in capacitance and the time constant of the capacitance response, emission rates, energy levels, and trap concentrations can be determined. A major advantage of using CTS is its ability to detect the presence of electrically active impurities that are invisible to other techniques, such as Zeeman effect atomic absorption, and the ability to detect more than one electrically active impurity in a sample. Examples of detection of majority and minority carrier traps from gold donor and acceptor centers in silicon using the capacitance transient spectrometer are given to illustrate the method and its sensitivity.

  11. Highly sensitive detection of DNA methylation levels by using a quantum dot-based FRET method

    NASA Astrophysics Data System (ADS)

    Ma, Yunfei; Zhang, Honglian; Liu, Fangming; Wu, Zhenhua; Lu, Shaohua; Jin, Qinghui; Zhao, Jianlong; Zhong, Xinhua; Mao, Hongju

    2015-10-01

    DNA methylation is the most frequently studied epigenetic modification that is strongly involved in genomic stability and cellular plasticity. Aberrant changes in DNA methylation status are ubiquitous in human cancer and the detection of these changes can be informative for cancer diagnosis. Herein, we reported a facile quantum dot-based (QD-based) fluorescence resonance energy transfer (FRET) technique for the detection of DNA methylation. The method relies on methylation-sensitive restriction enzymes for the differential digestion of genomic DNA based on its methylation status. Digested DNA is then subjected to PCR amplification for the incorporation of Alexa Fluor-647 (A647) fluorophores. DNA methylation levels can be detected qualitatively through gel analysis and quantitatively by the signal amplification from QDs to A647 during FRET. Furthermore, the methylation levels of three tumor suppressor genes, PCDHGB6, HOXA9 and RASSF1A, in 20 lung adenocarcinoma and 20 corresponding adjacent nontumorous tissue (NT) samples were measured to verify the feasibility of the QD-based FRET method and a high sensitivity for cancer detection (up to 90%) was achieved. Our QD-based FRET method is a convenient, continuous and high-throughput method, and is expected to be an alternative for detecting DNA methylation as a biomarker for certain human cancers.DNA methylation is the most frequently studied epigenetic modification that is strongly involved in genomic stability and cellular plasticity. Aberrant changes in DNA methylation status are ubiquitous in human cancer and the detection of these changes can be informative for cancer diagnosis. Herein, we reported a facile quantum dot-based (QD-based) fluorescence resonance energy transfer (FRET) technique for the detection of DNA methylation. The method relies on methylation-sensitive restriction enzymes for the differential digestion of genomic DNA based on its methylation status. Digested DNA is then subjected to PCR amplification for the incorporation of Alexa Fluor-647 (A647) fluorophores. DNA methylation levels can be detected qualitatively through gel analysis and quantitatively by the signal amplification from QDs to A647 during FRET. Furthermore, the methylation levels of three tumor suppressor genes, PCDHGB6, HOXA9 and RASSF1A, in 20 lung adenocarcinoma and 20 corresponding adjacent nontumorous tissue (NT) samples were measured to verify the feasibility of the QD-based FRET method and a high sensitivity for cancer detection (up to 90%) was achieved. Our QD-based FRET method is a convenient, continuous and high-throughput method, and is expected to be an alternative for detecting DNA methylation as a biomarker for certain human cancers. Electronic supplementary information (ESI) available: Synthesis of CdSe/CdS/ZnS core/shell/shell QDs. Sequences of primers used for amplifying the promoter regions in bisulfate-modified DNA. Comparison of detected methylation levels in different gene promoters using the QD-based FRET method versus bisulfite pyrosequencing. Methylation levels of the RASSF1A gene in one pair of NT and cancer samples as indicated by pyrosequencing. Theoretical calculation of the Förster distance R0. See DOI: 10.1039/c5nr04956c

  12. Evaluation of Modification of the 3M™ Molecular Detection Assay (MDA) Salmonella Method (2013.09) for the Detection of Salmonella in Selected Foods: Collaborative Study.

    PubMed

    Bird, Patrick; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Benzinger, M Joseph; Bedinghaus, Paige; Flannery, Jonathon; Crowley, Erin; Agin, James; Goins, David; Benesh, DeAnn; David, John

    2014-01-01

    The 3M(™) Molecular Detection Assay (MDA) Salmonella utilizes isothermal amplification of nucleic acid sequences with high specificity, efficiency, rapidity and bioluminescence to detect amplification of Salmonella spp. in food, food-related, and environmental samples after enrichment. A method modification and matrix extension study of the previously approved AOAC Official Method(SM) 2013.09 was conducted, and approval of the modification was received on March 20, 2014. Using an unpaired study design in a multilaboratory collaborative study, the 3M MDA Salmonella method was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) Microbiology Laboratory Guidebook (MLG) 4.05 (2011), Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish Products for raw ground beef and the U.S. Food and Drug Administration (FDA)/Bacteriological Analytical Manual (BAM) Chapter 5, Salmonella reference method for wet dog food following the current AOAC guidelines. A total of 20 laboratories participated. For the 3M MDA Salmonella method, raw ground beef was analyzed using 25 g test portions, and wet dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each matrix were analyzed. Each matrix was artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1512 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD). For the low-level raw ground beef test portions, the following dLPOD (difference between the LPODs of the reference and candidate method) values with 95% confidence intervals were obtained: -0.01 (-0.14, +0.12). For the low-level wet dog food test portions, the following dLPOD with 95% confidence intervals were obtained: -0.04 (-0.16, +0.09). No significant differences were observed in the number of positive samples detected by the 3M MDA Salmonella method versus either the USDA/FSIS-MLG or FDA/BAM methods.

  13. Ultra-high sensitivity radiation detection apparatus and method

    DOEpatents

    Gross, Kenneth C.; Valentine, John D.; Markum, Francis; Zawadzki, Mary; Dickerman, Charles

    1999-01-01

    A method and apparatus are provided to concentrate and detect very low levels of radioactive noble gases from the atmosphere. More specifically the invention provides a method and apparatus to concentrate xenon, krypton and radon in an organic fluid and to detect these gases by the radioactive emissions.

  14. Statistical sensor fusion analysis of near-IR polarimetric and thermal imagery for the detection of minelike targets

    NASA Astrophysics Data System (ADS)

    Weisenseel, Robert A.; Karl, William C.; Castanon, David A.; DiMarzio, Charles A.

    1999-02-01

    We present an analysis of statistical model based data-level fusion for near-IR polarimetric and thermal data, particularly for the detection of mines and mine-like targets. Typical detection-level data fusion methods, approaches that fuse detections from individual sensors rather than fusing at the level of the raw data, do not account rationally for the relative reliability of different sensors, nor the redundancy often inherent in multiple sensors. Representative examples of such detection-level techniques include logical AND/OR operations on detections from individual sensors and majority vote methods. In this work, we exploit a statistical data model for the detection of mines and mine-like targets to compare and fuse multiple sensor channels. Our purpose is to quantify the amount of knowledge that each polarimetric or thermal channel supplies to the detection process. With this information, we can make reasonable decisions about the usefulness of each channel. We can use this information to improve the detection process, or we can use it to reduce the number of required channels.

  15. Colorimetric detection of uranium in water

    DOEpatents

    DeVol, Timothy A [Clemson, SC; Hixon, Amy E [Piedmont, SC; DiPrete, David P [Evans, GA

    2012-03-13

    Disclosed are methods, materials and systems that can be used to determine qualitatively or quantitatively the level of uranium contamination in water samples. Beneficially, disclosed systems are relatively simple and cost-effective. For example, disclosed systems can be utilized by consumers having little or no training in chemical analysis techniques. Methods generally include a concentration step and a complexation step. Uranium concentration can be carried out according to an extraction chromatographic process and complexation can chemically bind uranium with a detectable substance such that the formed substance is visually detectable. Methods can detect uranium contamination down to levels even below the MCL as established by the EPA.

  16. Assessment of groundwater, soil-gas, and soil contamination at the Vietnam Armor Training Facility, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, Georgia, assessed the groundwater, soil gas, and soil for contaminants at the Vietnam Armor Training Facility (VATF) at Fort Gordon, from October 2009 to September 2010. The assessment included the detection of organic compounds in the groundwater and soil gas, and inorganic compounds in the soil. In addition, organic contaminant assessment included organic compounds classified as explosives and chemical agents in selected areas. The assessment was conducted to provide environmental contamination data to the U.S. Army at Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Four passive samplers were deployed in groundwater wells at the VATF in Fort Gordon. Total petroleum hydrocarbons were detected above the method detection level at all four wells. The only other volatile organic compounds detected above their method detection level were undecane and pentadecane, which were detected in two of the four wells sampled. Soil-gas samplers were deployed at 72 locations in a grid pattern across the VATF. Total petroleum hydrocarbons were detected in 71 of the 72 samplers (one sampler was destroyed in the field and not analyzed) at levels above the method detection level, and the combined mass of benzene, toluene, ethylbenzene, and total xylene was detected above the detection level in 31 of the 71 samplers that were analyzed. Other volatile organic compounds detected above their respective method detection levels were naphthalene, 2-methyl-naphthalene, tridecane, 1,2,4-trimethylbenzene, and perchloroethene. Subsequent to the soil-gas survey, four areas determined to have elevated contaminant mass were selected and sampled for explosives and chemical agents. No detections of explosives or chemical agents above their respective method detection levels were found at any of the sampling locations. The same four locations that were sampled for explosives and chemical agents were selected for the collection of soil samples. A fifth location also was selected on the basis of the elevated contaminant mass of the soil-gas survey. No metals that exceeded the Regional Screening Levels for Industrial Soils as classified by the U.S. Environmental Protection Agency were detected at any of the five VATF locations. The soil samples also were compared to values from the ambient, uncontaminated (background) levels for soils in South Carolina, as classified by the South Carolina Department of Health and Environmental Control. Because South Carolina is adjacent to Georgia and the soils in the coastal plain are similar, these comparisons are valid. No similar values are available for Georgia to use for comparison purposes. The metals that were detected above the ambient background levels for South Carolina, as classified by the South Carolina Department of Health and Environmental Control, include aluminum, arsenic, barium, beryllium, calcium, chromium, copper, iron, lead, magnesium, manganese, nickel, potassium, sodium, and zinc.

  17. A multiscale method for a robust detection of the default mode network

    NASA Astrophysics Data System (ADS)

    Baquero, Katherine; Gómez, Francisco; Cifuentes, Christian; Guldenmund, Pieter; Demertzi, Athena; Vanhaudenhuyse, Audrey; Gosseries, Olivia; Tshibanda, Jean-Flory; Noirhomme, Quentin; Laureys, Steven; Soddu, Andrea; Romero, Eduardo

    2013-11-01

    The Default Mode Network (DMN) is a resting state network widely used for the analysis and diagnosis of mental disorders. It is normally detected in fMRI data, but for its detection in data corrupted by motion artefacts or low neuronal activity, the use of a robust analysis method is mandatory. In fMRI it has been shown that the signal-to-noise ratio (SNR) and the detection sensitivity of neuronal regions is increased with di erent smoothing kernels sizes. Here we propose to use a multiscale decomposition based of a linear scale-space representation for the detection of the DMN. Three main points are proposed in this methodology: rst, the use of fMRI data at di erent smoothing scale-spaces, second, detection of independent neuronal components of the DMN at each scale by using standard preprocessing methods and ICA decomposition at scale-level, and nally, a weighted contribution of each scale by the Goodness of Fit measurement. This method was applied to a group of control subjects and was compared with a standard preprocesing baseline. The detection of the DMN was improved at single subject level and at group level. Based on these results, we suggest to use this methodology to enhance the detection of the DMN in data perturbed with artefacts or applied to subjects with low neuronal activity. Furthermore, the multiscale method could be extended for the detection of other resting state neuronal networks.

  18. Use of diaminofluoresceins to detect and measure nitric oxide in low level generating human immune cells.

    PubMed

    Tiscornia, Adriana; Cairoli, Ernesto; Marquez, Maria; Denicola, Ana; Pritsch, Otto; Cayota, Alfonso

    2009-03-15

    Nitric oxide ((*)NO) has been implicated in multiple physiological and pathological immune processes. Different methods have been developed to detect and quantify (*)NO, where one of the principal difficulties are the accurately detection in cellular system with low levels of (*)NO production. The choice of the (*)NO detection method to be used depends on the characteristics of the experimental system and the levels of (*)NO production which depend on either the organism source of samples or the experimental conditions. Recently, high sensitive methods to detect and image (*)NO have been reported using 4,5-diaminofluorescein-based fluorescent probes (DAF) and its derivate 4,5-diaminofluorescein diacetate (DAF-2 DA). This work was aimed to adapt and optimize the use of DAF probes to detect and quantify the (*)NO production in systems of high, moderate and low out-put production, especially in human PBMC and their subpopulations. Here, we report an original experimental design which is useful to detect and estimate (*)NO fluxes in human PBMC and their subpopulations with high specificity and sensitivity.

  19. Object Detection and Classification by Decision-Level Fusion for Intelligent Vehicle Systems.

    PubMed

    Oh, Sang-Il; Kang, Hang-Bong

    2017-01-22

    To understand driving environments effectively, it is important to achieve accurate detection and classification of objects detected by sensor-based intelligent vehicle systems, which are significantly important tasks. Object detection is performed for the localization of objects, whereas object classification recognizes object classes from detected object regions. For accurate object detection and classification, fusing multiple sensor information into a key component of the representation and perception processes is necessary. In this paper, we propose a new object-detection and classification method using decision-level fusion. We fuse the classification outputs from independent unary classifiers, such as 3D point clouds and image data using a convolutional neural network (CNN). The unary classifiers for the two sensors are the CNN with five layers, which use more than two pre-trained convolutional layers to consider local to global features as data representation. To represent data using convolutional layers, we apply region of interest (ROI) pooling to the outputs of each layer on the object candidate regions generated using object proposal generation to realize color flattening and semantic grouping for charge-coupled device and Light Detection And Ranging (LiDAR) sensors. We evaluate our proposed method on a KITTI benchmark dataset to detect and classify three object classes: cars, pedestrians and cyclists. The evaluation results show that the proposed method achieves better performance than the previous methods. Our proposed method extracted approximately 500 proposals on a 1226 × 370 image, whereas the original selective search method extracted approximately 10 6 × n proposals. We obtained classification performance with 77.72% mean average precision over the entirety of the classes in the moderate detection level of the KITTI benchmark dataset.

  20. Object Detection and Classification by Decision-Level Fusion for Intelligent Vehicle Systems

    PubMed Central

    Oh, Sang-Il; Kang, Hang-Bong

    2017-01-01

    To understand driving environments effectively, it is important to achieve accurate detection and classification of objects detected by sensor-based intelligent vehicle systems, which are significantly important tasks. Object detection is performed for the localization of objects, whereas object classification recognizes object classes from detected object regions. For accurate object detection and classification, fusing multiple sensor information into a key component of the representation and perception processes is necessary. In this paper, we propose a new object-detection and classification method using decision-level fusion. We fuse the classification outputs from independent unary classifiers, such as 3D point clouds and image data using a convolutional neural network (CNN). The unary classifiers for the two sensors are the CNN with five layers, which use more than two pre-trained convolutional layers to consider local to global features as data representation. To represent data using convolutional layers, we apply region of interest (ROI) pooling to the outputs of each layer on the object candidate regions generated using object proposal generation to realize color flattening and semantic grouping for charge-coupled device and Light Detection And Ranging (LiDAR) sensors. We evaluate our proposed method on a KITTI benchmark dataset to detect and classify three object classes: cars, pedestrians and cyclists. The evaluation results show that the proposed method achieves better performance than the previous methods. Our proposed method extracted approximately 500 proposals on a 1226×370 image, whereas the original selective search method extracted approximately 106×n proposals. We obtained classification performance with 77.72% mean average precision over the entirety of the classes in the moderate detection level of the KITTI benchmark dataset. PMID:28117742

  1. Community Detection in Complex Networks via Clique Conductance.

    PubMed

    Lu, Zhenqi; Wahlström, Johan; Nehorai, Arye

    2018-04-13

    Network science plays a central role in understanding and modeling complex systems in many areas including physics, sociology, biology, computer science, economics, politics, and neuroscience. One of the most important features of networks is community structure, i.e., clustering of nodes that are locally densely interconnected. Communities reveal the hierarchical organization of nodes, and detecting communities is of great importance in the study of complex systems. Most existing community-detection methods consider low-order connection patterns at the level of individual links. But high-order connection patterns, at the level of small subnetworks, are generally not considered. In this paper, we develop a novel community-detection method based on cliques, i.e., local complete subnetworks. The proposed method overcomes the deficiencies of previous similar community-detection methods by considering the mathematical properties of cliques. We apply the proposed method to computer-generated graphs and real-world network datasets. When applied to networks with known community structure, the proposed method detects the structure with high fidelity and sensitivity. When applied to networks with no a priori information regarding community structure, the proposed method yields insightful results revealing the organization of these complex networks. We also show that the proposed method is guaranteed to detect near-optimal clusters in the bipartition case.

  2. A 5-mC Dot Blot Assay Quantifying the DNA Methylation Level of Chondrocyte Dedifferentiation In Vitro.

    PubMed

    Jia, Zhaofeng; Liang, Yujie; Ma, Bin; Xu, Xiao; Xiong, Jianyi; Duan, Li; Wang, Daping

    2017-05-17

    The dedifferentiation of hyaline chondrocytes into fibroblastic chondrocytes often accompanies monolayer expansion of chondrocytes in vitro. The global DNA methylation level of chondrocytes is considered to be a suitable biomarker for the loss of the chondrocyte phenotype. However, results based on different experimental methods can be inconsistent. Therefore, it is important to establish a precise, simple, and rapid method to quantify global DNA methylation levels during chondrocyte dedifferentiation. Current genome-wide methylation analysis techniques largely rely on bisulfite genomic sequencing. Due to DNA degradation during bisulfite conversion, these methods typically require a large sample volume. Other methods used to quantify global DNA methylation levels include high-performance liquid chromatography (HPLC). However, HPLC requires complete digestion of genomic DNA. Additionally, the prohibitively high cost of HPLC instruments limits HPLC's wider application. In this study, genomic DNA (gDNA) was extracted from human chondrocytes cultured with varying number of passages. The gDNA methylation level was detected using a methylation-specific dot blot assay. In this dot blot approach, a gDNA mixture containing the methylated DNA to be detected was spotted directly onto an N + membrane as a dot inside a previously drawn circular template pattern. Compared with other gel electrophoresis-based blotting approaches and other complex blotting procedures, the dot blot method saves significant time. In addition, dot blots can detect overall DNA methylation level using a commercially available 5-mC antibody. We found that the DNA methylation level differed between the monolayer subcultures, and therefore could play a key role in chondrocyte dedifferentiation. The 5-mC dot blot is a reliable, simple, and rapid method to detect the general DNA methylation level to evaluate chondrocyte phenotype.

  3. Determination of Total Petroleum Hydrocarbons in Australian Groundwater Through the Improvised Gas Chromatography-Flame Ionization Detection Technique.

    PubMed

    Faustorilla, Maria Vilma; Chen, Zuliang; Dharmarajan, Rajarathnam; Naidu, Ravendra

    2017-09-01

    Assessment of total petroleum hydrocarbons (TPHs) from contaminated sites demands routine and reliable measurement at trace levels. However, the detection limits of these methods need to be improved. This study developed the programmable temperature vaporization-large volume injection (PTV-LVI) method to quantify TPHs through gas chromatography-flame ionization detection. This configuration enhances the method sensitivity for trace level detections through large volume injections and pre-concentration of analytes along the injection liner. The method was evaluated for the three commonly observed hydrocarbon fractions: C10-C14, C15-C28 and C29-C36. In comparison with conventional injection methods (splitless and pulsed splitless), PTV-LVI showed R2 values > 0.999 with enhanced limits of detection and limits of quantification values. The method was applied to real samples for routine environmental monitoring of TPHs in an Australian contaminated site characterized by refueling station. Analysis of groundwater samples in the area showed a wide range of TPH concentrations as follows: 66-1,546,000 (C10-C14), 216-22,762 (C15-C28) and 105-2,103 (C29-C36) μg/L. This method has detected trace levels, thereby measuring a wider concentration range of TPHs. These more accurate measurements can lead to the appropriate application of risk assessments and remediation techniques. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance

    NASA Technical Reports Server (NTRS)

    Seasly, Elaine; Dever, Jason; Stuban, Steven M. F.

    2016-01-01

    Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.

  5. Robust Fault Detection for Switched Fuzzy Systems With Unknown Input.

    PubMed

    Han, Jian; Zhang, Huaguang; Wang, Yingchun; Sun, Xun

    2017-10-03

    This paper investigates the fault detection problem for a class of switched nonlinear systems in the T-S fuzzy framework. The unknown input is considered in the systems. A novel fault detection unknown input observer design method is proposed. Based on the proposed observer, the unknown input can be removed from the fault detection residual. The weighted H∞ performance level is considered to ensure the robustness. In addition, the weighted H₋ performance level is introduced, which can increase the sensibility of the proposed detection method. To verify the proposed scheme, a numerical simulation example and an electromechanical system simulation example are provided at the end of this paper.

  6. Monitoring Farmland Loss Caused by Urbanization in Beijing from Modis Time Series Using Hierarchical Hidden Markov Model

    NASA Astrophysics Data System (ADS)

    Yuan, Y.; Meng, Y.; Chen, Y. X.; Jiang, C.; Yue, A. Z.

    2018-04-01

    In this study, we proposed a method to map urban encroachment onto farmland using satellite image time series (SITS) based on the hierarchical hidden Markov model (HHMM). In this method, the farmland change process is decomposed into three hierarchical levels, i.e., the land cover level, the vegetation phenology level, and the SITS level. Then a three-level HHMM is constructed to model the multi-level semantic structure of farmland change process. Once the HHMM is established, a change from farmland to built-up could be detected by inferring the underlying state sequence that is most likely to generate the input time series. The performance of the method is evaluated on MODIS time series in Beijing. Results on both simulated and real datasets demonstrate that our method improves the change detection accuracy compared with the HMM-based method.

  7. Assessment of soil-gas and soil contamination at the Patterson Anti-Tank Range, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Caldwell, Andral W.; Falls, W. Fred; Guimaraes, Wladmir B.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    Soil gas and soil were assessed for contaminants at the Patterson Anti-Tank Range at Fort Gordon, Georgia, from October 2009 to September 2010. The assessment included identifying and delineating organic contaminants present in soil-gas samplers from the area estimated to be the Patterson Anti-Tank Range and in the hyporheic zone and floodplain of Brier Creek. This assessment was conducted to provide environmental contamination data to Fort Gordon personnel pursuant to requirements for the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Soil-gas samplers in the hyporheic zone and floodplain of Brier Creek contained total petroleum hydrocarbons, benzene, octane, and pentadecane concentrations above method detection levels. All soil-gas samplers within the boundary of the Patterson Anti-Tank Range contained total petroleum hydrocarbons above the method detection level. The highest total petroleum hydrocarbon mass detected was 147.09 micrograms in a soil-gas sampler located near the middle of the site and near the remnants of a manmade earthen mound and trench. The highest toluene mass detected was 1.04 micrograms and was located in the center of the Patterson Anti-Tank Range and coincides with a manmade earthen mound. Some soil-gas samplers installed detected undecane masses greater than the method detection level of 0.04 microgram, with the highest detection of soil-gas undecane mass of 58.64 micrograms collected along the southern boundary of the site. Some soil-gas samplers were installed in areas of high-contaminant mass to assess for explosives and chemical agents. Explosives or chemical agents were not detected above their respective method detection levels for all soil-gas samplers installed.

  8. Ultratrace level determination and quantitative analysis of kidney injury biomarkers in patient samples attained by zinc oxide nanorods

    NASA Astrophysics Data System (ADS)

    Singh, Manpreet; Alabanza, Anginelle; Gonzalez, Lorelis E.; Wang, Weiwei; Reeves, W. Brian; Hahm, Jong-In

    2016-02-01

    Determining ultratrace amounts of protein biomarkers in patient samples in a straightforward and quantitative manner is extremely important for early disease diagnosis and treatment. Here, we successfully demonstrate the novel use of zinc oxide nanorods (ZnO NRs) in the ultrasensitive and quantitative detection of two acute kidney injury (AKI)-related protein biomarkers, tumor necrosis factor (TNF)-α and interleukin (IL)-8, directly from patient samples. We first validate the ZnO NRs-based IL-8 results via comparison with those obtained from using a conventional enzyme-linked immunosorbent method in samples from 38 individuals. We further assess the full detection capability of the ZnO NRs-based technique by quantifying TNF-α, whose levels in human urine are often below the detection limits of conventional methods. Using the ZnO NR platforms, we determine the TNF-α concentrations of all 46 patient samples tested, down to the fg per mL level. Subsequently, we screen for TNF-α levels in approximately 50 additional samples collected from different patient groups in order to demonstrate a potential use of the ZnO NRs-based assay in assessing cytokine levels useful for further clinical monitoring. Our research efforts demonstrate that ZnO NRs can be straightforwardly employed in the rapid, ultrasensitive, quantitative, and simultaneous detection of multiple AKI-related biomarkers directly in patient urine samples, providing an unparalleled detection capability beyond those of conventional analysis methods. Additional key advantages of the ZnO NRs-based approach include a fast detection speed, low-volume assay condition, multiplexing ability, and easy automation/integration capability to existing fluorescence instrumentation. Therefore, we anticipate that our ZnO NRs-based detection method will be highly beneficial for overcoming the frequent challenges in early biomarker development and treatment assessment, pertaining to the facile and ultrasensitive quantification of hard-to-trace biomolecules.Determining ultratrace amounts of protein biomarkers in patient samples in a straightforward and quantitative manner is extremely important for early disease diagnosis and treatment. Here, we successfully demonstrate the novel use of zinc oxide nanorods (ZnO NRs) in the ultrasensitive and quantitative detection of two acute kidney injury (AKI)-related protein biomarkers, tumor necrosis factor (TNF)-α and interleukin (IL)-8, directly from patient samples. We first validate the ZnO NRs-based IL-8 results via comparison with those obtained from using a conventional enzyme-linked immunosorbent method in samples from 38 individuals. We further assess the full detection capability of the ZnO NRs-based technique by quantifying TNF-α, whose levels in human urine are often below the detection limits of conventional methods. Using the ZnO NR platforms, we determine the TNF-α concentrations of all 46 patient samples tested, down to the fg per mL level. Subsequently, we screen for TNF-α levels in approximately 50 additional samples collected from different patient groups in order to demonstrate a potential use of the ZnO NRs-based assay in assessing cytokine levels useful for further clinical monitoring. Our research efforts demonstrate that ZnO NRs can be straightforwardly employed in the rapid, ultrasensitive, quantitative, and simultaneous detection of multiple AKI-related biomarkers directly in patient urine samples, providing an unparalleled detection capability beyond those of conventional analysis methods. Additional key advantages of the ZnO NRs-based approach include a fast detection speed, low-volume assay condition, multiplexing ability, and easy automation/integration capability to existing fluorescence instrumentation. Therefore, we anticipate that our ZnO NRs-based detection method will be highly beneficial for overcoming the frequent challenges in early biomarker development and treatment assessment, pertaining to the facile and ultrasensitive quantification of hard-to-trace biomolecules. Electronic supplementary information (ESI) available: Typical SEM images of the ZnO NRs used in the biomarker assays are provided in Fig. S1. See DOI: 10.1039/c5nr08706f

  9. Level 2 validation of a flow cytometric method for detection of Escherichia coli O157:H7 in raw spinach.

    PubMed

    Williams, Anna J; Cooper, Willie M; Summage-West, Christine V; Sims, Lillie M; Woodruff, Robert; Christman, Jessica; Moskal, Ted J; Ramsaroop, Shawn; Sutherland, John B; Alusta, Pierre; Wilkes, Jon G; Buzatu, Dan A

    2015-12-23

    The Bacteriological Analytical Manual (BAM) method currently used by the United States Food and Drug Administration (FDA) to detect Escherichia coli O157:H7 in spinach was systematically compared to a new flow cytometry based method. This Food and Drug Administration (FDA) level 2 external laboratory validation study was designed to determine the latter method's sensitivity and speed for analysis of this pathogen in raw spinach. Detection of target cell inoculations with a low cell count is critical, since enterohemorrhagic strains of E. coli require an infective dose of as few as 10 cells (Schmid-Hempel and Frank, 2007). Although, according to the FDA, the infectious dose is unknown (Food and Drug Administration, 1993). Therefore, the inoculation level into the spinach, a total of 2.0±2.6 viable E. coli O157 cells, was specified to yield between 25% and 75% detection by the new method, out of 20 samples (10 positives and 10 negatives). This criterion was met in that the new method detected 60% of the nominally positive samples; the corresponding sensitivity of the reference method was 50%. For both methods the most likely explanation for false negatives was that no viable cells were actually introduced into the sample. In this validation study, the flow cytometry method was equal to the BAM in sensitivity and far superior in speed. Published by Elsevier B.V.

  10. Assessment of Soil-Gas and Soil Contamination at the Former Military Police Range, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Falls, W. Fred; Caldwell, Andral W.; Guimaraes, Wladmir B.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    Soil gas and soil were assessed for organic and inorganic contaminants at the former military police range at Fort Gordon, Georgia, from May to September 2010. The assessment evaluated organic contaminants in soil-gas samplers and inorganic contaminants in soil samples. This assessment was conducted to provide environmental contamination data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Soil-gas samplers deployed and collected from May 20 to 24, 2010, identified masses above method detection level for total petroleum hydrocarbons, gasoline-related and diesel-related compounds, and chloroform. Most of these detections were in the southwestern quarter of the study area and adjacent to the road on the eastern boundary of the site. Nine of the 11 chloroform detections were in the southern half of the study area. One soil-gas sampler deployed adjacent to the road on the southern boundary of the site detected a mass of tetrachloroethene greater than, but close to, the method detection level of 0.02 microgram. For soil-gas samplers deployed and collected from September 15 to 22, 2010, none of the selected organic compounds classified as chemical agents and explosives were detected above method detection levels. Inorganic concentrations in the five soil samples collected at the site did not exceed the U.S. Environmental Protection Agency regional screening levels for industrial soil and were at or below background levels for similar rocks and strata in South Carolina.

  11. Regional Principal Color Based Saliency Detection

    PubMed Central

    Lou, Jing; Ren, Mingwu; Wang, Huan

    2014-01-01

    Saliency detection is widely used in many visual applications like image segmentation, object recognition and classification. In this paper, we will introduce a new method to detect salient objects in natural images. The approach is based on a regional principal color contrast modal, which incorporates low-level and medium-level visual cues. The method allows a simple computation of color features and two categories of spatial relationships to a saliency map, achieving higher F-measure rates. At the same time, we present an interpolation approach to evaluate resulting curves, and analyze parameters selection. Our method enables the effective computation of arbitrary resolution images. Experimental results on a saliency database show that our approach produces high quality saliency maps and performs favorably against ten saliency detection algorithms. PMID:25379960

  12. A robust object-based shadow detection method for cloud-free high resolution satellite images over urban areas and water bodies

    NASA Astrophysics Data System (ADS)

    Tatar, Nurollah; Saadatseresht, Mohammad; Arefi, Hossein; Hadavand, Ahmad

    2018-06-01

    Unwanted contrast in high resolution satellite images such as shadow areas directly affects the result of further processing in urban remote sensing images. Detecting and finding the precise position of shadows is critical in different remote sensing processing chains such as change detection, image classification and digital elevation model generation from stereo images. The spectral similarity between shadow areas, water bodies, and some dark asphalt roads makes the development of robust shadow detection algorithms challenging. In addition, most of the existing methods work on pixel-level and neglect the contextual information contained in neighboring pixels. In this paper, a new object-based shadow detection framework is introduced. In the proposed method a pixel-level shadow mask is built by extending established thresholding methods with a new C4 index which enables to solve the ambiguity of shadow and water bodies. Then the pixel-based results are further processed in an object-based majority analysis to detect the final shadow objects. Four different high resolution satellite images are used to validate this new approach. The result shows the superiority of the proposed method over some state-of-the-art shadow detection method with an average of 96% in F-measure.

  13. The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain

    PubMed Central

    Chobtang, Jeerasak; de Boer, Imke J. M.; Hoogenboom, Ron L. A. P.; Haasnoot, Willem; Kijlstra, Aize; Meerburg, Bastiaan G.

    2011-01-01

    Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain. PMID:22247688

  14. The need and potential of biosensors to detect dioxins and dioxin-like polychlorinated biphenyls along the milk, eggs and meat food chain.

    PubMed

    Chobtang, Jeerasak; de Boer, Imke J M; Hoogenboom, Ron L A P; Haasnoot, Willem; Kijlstra, Aize; Meerburg, Bastiaan G

    2011-01-01

    Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain.

  15. Mapping Health Data: Improved Privacy Protection With Donut Method Geomasking

    PubMed Central

    Hampton, Kristen H.; Fitch, Molly K.; Allshouse, William B.; Doherty, Irene A.; Gesink, Dionne C.; Leone, Peter A.; Serre, Marc L.; Miller, William C.

    2010-01-01

    A major challenge in mapping health data is protecting patient privacy while maintaining the spatial resolution necessary for spatial surveillance and outbreak identification. A new adaptive geomasking technique, referred to as the donut method, extends current methods of random displacement by ensuring a user-defined minimum level of geoprivacy. In donut method geomasking, each geocoded address is relocated in a random direction by at least a minimum distance, but less than a maximum distance. The authors compared the donut method with current methods of random perturbation and aggregation regarding measures of privacy protection and cluster detection performance by masking multiple disease field simulations under a range of parameters. Both the donut method and random perturbation performed better than aggregation in cluster detection measures. The performance of the donut method in geoprivacy measures was at least 42.7% higher and in cluster detection measures was less than 4.8% lower than that of random perturbation. Results show that the donut method provides a consistently higher level of privacy protection with a minimal decrease in cluster detection performance, especially in areas where the risk to individual geoprivacy is greatest. PMID:20817785

  16. Mapping health data: improved privacy protection with donut method geomasking.

    PubMed

    Hampton, Kristen H; Fitch, Molly K; Allshouse, William B; Doherty, Irene A; Gesink, Dionne C; Leone, Peter A; Serre, Marc L; Miller, William C

    2010-11-01

    A major challenge in mapping health data is protecting patient privacy while maintaining the spatial resolution necessary for spatial surveillance and outbreak identification. A new adaptive geomasking technique, referred to as the donut method, extends current methods of random displacement by ensuring a user-defined minimum level of geoprivacy. In donut method geomasking, each geocoded address is relocated in a random direction by at least a minimum distance, but less than a maximum distance. The authors compared the donut method with current methods of random perturbation and aggregation regarding measures of privacy protection and cluster detection performance by masking multiple disease field simulations under a range of parameters. Both the donut method and random perturbation performed better than aggregation in cluster detection measures. The performance of the donut method in geoprivacy measures was at least 42.7% higher and in cluster detection measures was less than 4.8% lower than that of random perturbation. Results show that the donut method provides a consistently higher level of privacy protection with a minimal decrease in cluster detection performance, especially in areas where the risk to individual geoprivacy is greatest.

  17. Diagnosing and ranking retinopathy disease level using diabetic fundus image recuperation approach.

    PubMed

    Somasundaram, K; Rajendran, P Alli

    2015-01-01

    Retinal fundus images are widely used in diagnosing different types of eye diseases. The existing methods such as Feature Based Macular Edema Detection (FMED) and Optimally Adjusted Morphological Operator (OAMO) effectively detected the presence of exudation in fundus images and identified the true positive ratio of exudates detection, respectively. These mechanically detected exudates did not include more detailed feature selection technique to the system for detection of diabetic retinopathy. To categorize the exudates, Diabetic Fundus Image Recuperation (DFIR) method based on sliding window approach is developed in this work to select the features of optic cup in digital retinal fundus images. The DFIR feature selection uses collection of sliding windows with varying range to obtain the features based on the histogram value using Group Sparsity Nonoverlapping Function. Using support vector model in the second phase, the DFIR method based on Spiral Basis Function effectively ranks the diabetic retinopathy disease level. The ranking of disease level on each candidate set provides a much promising result for developing practically automated and assisted diabetic retinopathy diagnosis system. Experimental work on digital fundus images using the DFIR method performs research on the factors such as sensitivity, ranking efficiency, and feature selection time.

  18. Diagnosing and Ranking Retinopathy Disease Level Using Diabetic Fundus Image Recuperation Approach

    PubMed Central

    Somasundaram, K.; Alli Rajendran, P.

    2015-01-01

    Retinal fundus images are widely used in diagnosing different types of eye diseases. The existing methods such as Feature Based Macular Edema Detection (FMED) and Optimally Adjusted Morphological Operator (OAMO) effectively detected the presence of exudation in fundus images and identified the true positive ratio of exudates detection, respectively. These mechanically detected exudates did not include more detailed feature selection technique to the system for detection of diabetic retinopathy. To categorize the exudates, Diabetic Fundus Image Recuperation (DFIR) method based on sliding window approach is developed in this work to select the features of optic cup in digital retinal fundus images. The DFIR feature selection uses collection of sliding windows with varying range to obtain the features based on the histogram value using Group Sparsity Nonoverlapping Function. Using support vector model in the second phase, the DFIR method based on Spiral Basis Function effectively ranks the diabetic retinopathy disease level. The ranking of disease level on each candidate set provides a much promising result for developing practically automated and assisted diabetic retinopathy diagnosis system. Experimental work on digital fundus images using the DFIR method performs research on the factors such as sensitivity, ranking efficiency, and feature selection time. PMID:25945362

  19. Pitfalls in the detection of cholesterol in Huntington's disease models.

    PubMed

    Marullo, Manuela; Valenza, Marta; Leoni, Valerio; Caccia, Claudio; Scarlatti, Chiara; De Mario, Agnese; Zuccato, Chiara; Di Donato, Stefano; Carafoli, Ernesto; Cattaneo, Elena

    2012-10-11

    Background Abnormalities in brain cholesterol homeostasis have been reported in Huntington's disease (HD), an adult-onset neurodegenerative disorder caused by an expansion in the number of CAG repeats in the huntingtin (HTT) gene. However, the results have been contradictory with respect to whether cholesterol levels increase or decrease in HD models. Biochemical and mass spectrometry methods show reduced levels of cholesterol precursors and cholesterol in HD cells and in the brains of several HD animal models. Abnormal brain cholesterol homeostasis was also inferred from studies in HD patients. In contrast, colorimetric and enzymatic methods indicate cholesterol accumulation in HD cells and tissues. Here we used several methods to investigate cholesterol levels in cultured cells in the presence or absence of mutant HTT protein. Results Colorimetric and enzymatic methods with low sensitivity gave variable results, whereas results from a sensitive analytical method, gas chromatography-mass spectrometry, were more reliable. Sample preparation, high cell density and cell clonality also influenced the detection of intracellular cholesterol. Conclusions Detection of cholesterol in HD samples by colorimetric and enzymatic assays should be supplemented by detection using more sensitive analytical methods. Care must be taken to prepare the sample appropriately. By evaluating lathosterol levels using isotopic dilution mass spectrometry, we confirmed reduced cholesterol biosynthesis in knock-in cells expressing the polyQ mutation in a constitutive or inducible manner. *Correspondence should be addressed to Elena Cattaneo: elena.cattaneo@unimi.it.

  20. Determination of dapsone in serum and saliva using reversed-phase high-performance liquid chromatography with ultraviolet or electrochemical detection.

    PubMed

    Moncrieff, J

    1994-03-18

    A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.

  1. Advancing the detection of steady-state visual evoked potentials in brain-computer interfaces.

    PubMed

    Abu-Alqumsan, Mohammad; Peer, Angelika

    2016-06-01

    Spatial filtering has proved to be a powerful pre-processing step in detection of steady-state visual evoked potentials and boosted typical detection rates both in offline analysis and online SSVEP-based brain-computer interface applications. State-of-the-art detection methods and the spatial filters used thereby share many common foundations as they all build upon the second order statistics of the acquired Electroencephalographic (EEG) data, that is, its spatial autocovariance and cross-covariance with what is assumed to be a pure SSVEP response. The present study aims at highlighting the similarities and differences between these methods. We consider the canonical correlation analysis (CCA) method as a basis for the theoretical and empirical (with real EEG data) analysis of the state-of-the-art detection methods and the spatial filters used thereby. We build upon the findings of this analysis and prior research and propose a new detection method (CVARS) that combines the power of the canonical variates and that of the autoregressive spectral analysis in estimating the signal and noise power levels. We found that the multivariate synchronization index method and the maximum contrast combination method are variations of the CCA method. All three methods were found to provide relatively unreliable detections in low signal-to-noise ratio (SNR) regimes. CVARS and the minimum energy combination methods were found to provide better estimates for different SNR levels. Our theoretical and empirical results demonstrate that the proposed CVARS method outperforms other state-of-the-art detection methods when used in an unsupervised fashion. Furthermore, when used in a supervised fashion, a linear classifier learned from a short training session is able to estimate the hidden user intention, including the idle state (when the user is not attending to any stimulus), rapidly, accurately and reliably.

  2. A morphological method for ammonia detection in liver

    PubMed Central

    Gutiérrez-de-Juan, Virginia; López de Davalillo, Sergio; Fernández-Ramos, David; Barbier-Torres, Lucía; Zubiete-Franco, Imanol; Fernández-Tussy, Pablo; Simon, Jorge; Lopitz-Otsoa, Fernando; de las Heras, Javier; Iruzubieta, Paula; Arias-Loste, María Teresa; Villa, Erica; Crespo, Javier; Andrade, Raúl; Lucena, M. Isabel; Varela-Rey, Marta; Lu, Shelly C.; Mato, José M.; Delgado, Teresa Cardoso

    2017-01-01

    Hyperammonemia is a metabolic condition characterized by elevated levels of ammonia and a common event in acute liver injury/failure and chronic liver disease. Even though hepatic ammonia levels are potential predictive factors of patient outcome, easy and inexpensive methods aiming at the detection of liver ammonia accumulation in the clinical setting remain unavailable. Thus, herein we have developed a morphological method, based on the utilization of Nessler´s reagent, to accurately and precisely detect the accumulation of ammonia in biological tissue. We have validated our method against a commercially available kit in mouse tissue samples and, by using this modified method, we have confirmed the hepatic accumulation of ammonia in clinical and animal models of acute and chronic advanced liver injury as well as in the progression of fatty liver disease. Overall, we propose a morphological method for ammonia detection in liver that correlates well with the degree of liver disease severity and therefore can be potentially used to predict patient outcome. PMID:28319158

  3. A morphological method for ammonia detection in liver.

    PubMed

    Gutiérrez-de-Juan, Virginia; López de Davalillo, Sergio; Fernández-Ramos, David; Barbier-Torres, Lucía; Zubiete-Franco, Imanol; Fernández-Tussy, Pablo; Simon, Jorge; Lopitz-Otsoa, Fernando; de Las Heras, Javier; Iruzubieta, Paula; Arias-Loste, María Teresa; Villa, Erica; Crespo, Javier; Andrade, Raúl; Lucena, M Isabel; Varela-Rey, Marta; Lu, Shelly C; Mato, José M; Delgado, Teresa Cardoso; Martínez-Chantar, María-Luz

    2017-01-01

    Hyperammonemia is a metabolic condition characterized by elevated levels of ammonia and a common event in acute liver injury/failure and chronic liver disease. Even though hepatic ammonia levels are potential predictive factors of patient outcome, easy and inexpensive methods aiming at the detection of liver ammonia accumulation in the clinical setting remain unavailable. Thus, herein we have developed a morphological method, based on the utilization of Nessler´s reagent, to accurately and precisely detect the accumulation of ammonia in biological tissue. We have validated our method against a commercially available kit in mouse tissue samples and, by using this modified method, we have confirmed the hepatic accumulation of ammonia in clinical and animal models of acute and chronic advanced liver injury as well as in the progression of fatty liver disease. Overall, we propose a morphological method for ammonia detection in liver that correlates well with the degree of liver disease severity and therefore can be potentially used to predict patient outcome.

  4. A new multi-spectral feature level image fusion method for human interpretation

    NASA Astrophysics Data System (ADS)

    Leviner, Marom; Maltz, Masha

    2009-03-01

    Various different methods to perform multi-spectral image fusion have been suggested, mostly on the pixel level. However, the jury is still out on the benefits of a fused image compared to its source images. We present here a new multi-spectral image fusion method, multi-spectral segmentation fusion (MSSF), which uses a feature level processing paradigm. To test our method, we compared human observer performance in a three-task experiment using MSSF against two established methods: averaging and principle components analysis (PCA), and against its two source bands, visible and infrared. The three tasks that we studied were: (1) simple target detection, (2) spatial orientation, and (3) camouflaged target detection. MSSF proved superior to the other fusion methods in all three tests; MSSF also outperformed the source images in the spatial orientation and camouflaged target detection tasks. Based on these findings, current speculation about the circumstances in which multi-spectral image fusion in general and specific fusion methods in particular would be superior to using the original image sources can be further addressed.

  5. Defect Detection in Textures through the Use of Entropy as a Means for Automatically Selecting the Wavelet Decomposition Level.

    PubMed

    Navarro, Pedro J; Fernández-Isla, Carlos; Alcover, Pedro María; Suardíaz, Juan

    2016-07-27

    This paper presents a robust method for defect detection in textures, entropy-based automatic selection of the wavelet decomposition level (EADL), based on a wavelet reconstruction scheme, for detecting defects in a wide variety of structural and statistical textures. Two main features are presented. One of the new features is an original use of the normalized absolute function value (NABS) calculated from the wavelet coefficients derived at various different decomposition levels in order to identify textures where the defect can be isolated by eliminating the texture pattern in the first decomposition level. The second is the use of Shannon's entropy, calculated over detail subimages, for automatic selection of the band for image reconstruction, which, unlike other techniques, such as those based on the co-occurrence matrix or on energy calculation, provides a lower decomposition level, thus avoiding excessive degradation of the image, allowing a more accurate defect segmentation. A metric analysis of the results of the proposed method with nine different thresholding algorithms determined that selecting the appropriate thresholding method is important to achieve optimum performance in defect detection. As a consequence, several different thresholding algorithms depending on the type of texture are proposed.

  6. EVOLUTION OF AN ANALYTICAL METHOD FOR HALOGENATED FURANONES IN DRINKING WATER

    EPA Science Inventory

    A unified method of detection for seven halogenated furanones present in drinking waters at the ng/L level has been developed. The use of GC/ECD makes this method amenable to manyenvironmental laboratories and water treatment plants in the United States. Detection limits observe...

  7. Evaluation of the 3M™ Molecular Detection Assay (MDA) 2 - Salmonella for the Detection of Salmonella spp. in Select Foods and Environmental Surfaces: Collaborative Study, First Action 2016.01.

    PubMed

    Bird, Patrick; Flannery, Jonathan; Crowley, Erin; Agin, James R; Goins, David; Monteroso, Lisa

    2016-07-01

    The 3M™ Molecular Detection Assay (MDA) 2 - Salmonella uses real-time isothermal technology for the rapid and accurate detection of Salmonella spp. from enriched select food, feed, and food-process environmental samples. The 3M MDA 2 - Salmonella was evaluated in a multilaboratory collaborative study using an unpaired study design. The 3M MDA 2 - Salmonella was compared to the U.S. Food and Drug Administration Bacteriological Analytical Manual Chapter 5 reference method for the detection of Salmonella in creamy peanut butter, and to the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook Chapter 4.08 reference method "Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products and Carcass and Environmental Samples" for the detection of Salmonella in raw ground beef (73% lean). Technicians from 16 laboratories located within the continental United States participated. Each matrix was evaluated at three levels of contamination: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). Statistical analysis was conducted according to the probability of detection (POD) statistical model. Results obtained for the low inoculum level test portions produced difference in collaborator POD values of 0.03 (95% confidence interval, -0.10 to 0.16) for raw ground beef and 0.06 (95% confidence interval, -0.06 to 0.18) for creamy peanut butter, indicating no statistically significant difference between the candidate and reference methods.

  8. Assessment of soil-gas and soil contamination at the South Prong Creek Disposal Area, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Caldwell, Andral W.; Falls, W. Fred; Guimaraes, Wladmir B.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    Soil gas and soil were assessed for contaminants at the South Prong Creek Disposal Area at Fort Gordon, Georgia, from October 2009 to September 2010. The assessment included identifying and delineating organic contaminants present in soil-gas and inorganic contaminants present in soil samples collected from the area estimated to be the South Prong Creek Disposal Area, including two seeps and the hyporheic zone. This assessment was conducted to provide environmental contamination data to Fort Gordon personnel pursuant to requirements for the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. All soil-gas samplers in the two seeps and the hyporheic zone contained total petroleum hydrocarbons above the method detection level. The highest total petroleum hydrocarbon concentration detected from the two seeps was 54.23 micrograms per liter, and the highest concentration in the hyporheic zone was 344.41 micrograms per liter. The soil-gas samplers within the boundary of the South Prong Creek Disposal Area and along the unnamed road contained total petroleum hydrocarbon mass above the method detection level. The highest total petroleum hydrocarbon mass detected was 147.09 micrograms in a soil-gas sampler near the middle of the unnamed road that traverses the South Prong Creek Disposal Area. The highest undecane mass detected was 4.48 micrograms near the location of the highest total petroleum hydrocarbon mass. Some soil-gas samplers detected undecane mass greater than the method detection level of 0.04 micrograms, with the highest detection of toluene mass of 109.72 micrograms in the same location as the highest total petroleum hydrocarbon mass. Soil-gas samplers installed in areas of high contaminant mass had no detections of explosives and chemical agents above their respective method detection levels. Inorganic concentrations in five soil samples did not exceed regional screening levels established by the U.S. Environmental Protection Agency. Barium concentrations, however, were up to four times higher than the background concentrations reported in similar Coastal Plain sediments of South Carolina.

  9. Heap/stack guard pages using a wakeup unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gooding, Thomas M; Satterfield, David L; Steinmacher-Burow, Burkhard

    A method and system for providing a memory access check on a processor including the steps of detecting accesses to a memory device including level-1 cache using a wakeup unit. The method includes invalidating level-1 cache ranges corresponding to a guard page, and configuring a plurality of wakeup address compare (WAC) registers to allow access to selected WAC registers. The method selects one of the plurality of WAC registers, and sets up a WAC register related to the guard page. The method configures the wakeup unit to interrupt on access of the selected WAC register. The method detects access ofmore » the memory device using the wakeup unit when a guard page is violated. The method generates an interrupt to the core using the wakeup unit, and determines the source of the interrupt. The method detects the activated WAC registers assigned to the violated guard page, and initiates a response.« less

  10. Detection of calcification clusters in digital breast tomosynthesis slices at different dose levels utilizing a SRSAR reconstruction and JAFROC

    NASA Astrophysics Data System (ADS)

    Timberg, P.; Dustler, M.; Petersson, H.; Tingberg, A.; Zackrisson, S.

    2015-03-01

    Purpose: To investigate detection performance for calcification clusters in reconstructed digital breast tomosynthesis (DBT) slices at different dose levels using a Super Resolution and Statistical Artifact Reduction (SRSAR) reconstruction method. Method: Simulated calcifications with irregular profile (0.2 mm diameter) where combined to form clusters that were added to projection images (1-3 per abnormal image) acquired on a DBT system (Mammomat Inspiration, Siemens). The projection images were dose reduced by software to form 35 abnormal cases and 25 normal cases as if acquired at 100%, 75% and 50% dose level (AGD of approximately 1.6 mGy for a 53 mm standard breast, measured according to EUREF v0.15). A standard FBP and a SRSAR reconstruction method (utilizing IRIS (iterative reconstruction filters), and outlier detection using Maximum-Intensity Projections and Average-Intensity Projections) were used to reconstruct single central slices to be used in a Free-response task (60 images per observer and dose level). Six observers participated and their task was to detect the clusters and assign confidence rating in randomly presented images from the whole image set (balanced by dose level). Each trial was separated by one weeks to reduce possible memory bias. The outcome was analyzed for statistical differences using Jackknifed Alternative Free-response Receiver Operating Characteristics. Results: The results indicate that it is possible reduce the dose by 50% with SRSAR without jeopardizing cluster detection. Conclusions: The detection performance for clusters can be maintained at a lower dose level by using SRSAR reconstruction.

  11. Applying the Multiple Signal Classification Method to Silent Object Detection Using Ambient Noise

    NASA Astrophysics Data System (ADS)

    Mori, Kazuyoshi; Yokoyama, Tomoki; Hasegawa, Akio; Matsuda, Minoru

    2004-05-01

    The revolutionary concept of using ocean ambient noise positively to detect objects, called acoustic daylight imaging, has attracted much attention. The authors attempted the detection of a silent target object using ambient noise and a wide-band beam former consisting of an array of receivers. In experimental results obtained in air, using the wide-band beam former, we successfully applied the delay-sum array (DSA) method to detect a silent target object in an acoustic noise field generated by a large number of transducers. This paper reports some experimental results obtained by applying the multiple signal classification (MUSIC) method to a wide-band beam former to detect silent targets. The ocean ambient noise was simulated by transducers decentralized to many points in air. Both MUSIC and DSA detected a spherical target object in the noise field. The relative power levels near the target obtained with MUSIC were compared with those obtained by DSA. Then the effectiveness of the MUSIC method was evaluated according to the rate of increase in the maximum and minimum relative power levels.

  12. Nested methylation-specific polymerase chain reaction cancer detection method

    DOEpatents

    Belinsky, Steven A [Albuquerque, NM; Palmisano, William A [Edgewood, NM

    2007-05-08

    A molecular marker-based method for monitoring and detecting cancer in humans. Aberrant methylation of gene promoters is a marker for cancer risk in humans. A two-stage, or "nested" polymerase chain reaction method is disclosed for detecting methylated DNA sequences at sufficiently high levels of sensitivity to permit cancer screening in biological fluid samples, such as sputum, obtained non-invasively. The method is for detecting the aberrant methylation of the p16 gene, O 6-methylguanine-DNA methyltransferase gene, Death-associated protein kinase gene, RAS-associated family 1 gene, or other gene promoters. The method offers a potentially powerful approach to population-based screening for the detection of lung and other cancers.

  13. Universal ligation-detection-reaction microarray applied for compost microbes

    PubMed Central

    Hultman, Jenni; Ritari, Jarmo; Romantschuk, Martin; Paulin, Lars; Auvinen, Petri

    2008-01-01

    Background Composting is one of the methods utilised in recycling organic communal waste. The composting process is dependent on aerobic microbial activity and proceeds through a succession of different phases each dominated by certain microorganisms. In this study, a ligation-detection-reaction (LDR) based microarray method was adapted for species-level detection of compost microbes characteristic of each stage of the composting process. LDR utilises the specificity of the ligase enzyme to covalently join two adjacently hybridised probes. A zip-oligo is attached to the 3'-end of one probe and fluorescent label to the 5'-end of the other probe. Upon ligation, the probes are combined in the same molecule and can be detected in a specific location on a universal microarray with complementary zip-oligos enabling equivalent hybridisation conditions for all probes. The method was applied to samples from Nordic composting facilities after testing and optimisation with fungal pure cultures and environmental clones. Results Probes targeted for fungi were able to detect 0.1 fmol of target ribosomal PCR product in an artificial reaction mixture containing 100 ng competing fungal ribosomal internal transcribed spacer (ITS) area or herring sperm DNA. The detection level was therefore approximately 0.04% of total DNA. Clone libraries were constructed from eight compost samples. The LDR microarray results were in concordance with the clone library sequencing results. In addition a control probe was used to monitor the per-spot hybridisation efficiency on the array. Conclusion This study demonstrates that the LDR microarray method is capable of sensitive and accurate species-level detection from a complex microbial community. The method can detect key species from compost samples, making it a basis for a tool for compost process monitoring in industrial facilities. PMID:19116002

  14. A comparative study of cultural methods for the detection of Salmonella in feed and feed ingredients

    PubMed Central

    Koyuncu, Sevinc; Haggblom, Per

    2009-01-01

    Background Animal feed as a source of infection to food producing animals is much debated. In order to increase our present knowledge about possible feed transmission it is important to know that the present isolation methods for Salmonella are reliable also for feed materials. In a comparative study the ability of the standard method used for isolation of Salmonella in feed in the Nordic countries, the NMKL71 method (Nordic Committee on Food Analysis) was compared to the Modified Semisolid Rappaport Vassiliadis method (MSRV) and the international standard method (EN ISO 6579:2002). Five different feed materials were investigated, namely wheat grain, soybean meal, rape seed meal, palm kernel meal, pellets of pig feed and also scrapings from a feed mill elevator. Four different levels of the Salmonella serotypes S. Typhimurium, S. Cubana and S. Yoruba were added to each feed material, respectively. For all methods pre-enrichment in Buffered Peptone Water (BPW) were carried out followed by enrichments in the different selective media and finally plating on selective agar media. Results The results obtained with all three methods showed no differences in detection levels, with an accuracy and sensitivity of 65% and 56%, respectively. However, Müller-Kauffmann tetrathionate-novobiocin broth (MKTTn), performed less well due to many false-negative results on Brilliant Green agar (BGA) plates. Compared to other feed materials palm kernel meal showed a higher detection level with all serotypes and methods tested. Conclusion The results of this study showed that the accuracy, sensitivity and specificity of the investigated cultural methods were equivalent. However, the detection levels for different feed and feed ingredients varied considerably. PMID:19192298

  15. A Comparison of the Capability of Sensitivity Level 3 and Sensitivity Level 4 Fluorescent Penetrants to Detect Fatigue Cracks in Aluminum

    NASA Technical Reports Server (NTRS)

    Parker, Bradford, H.

    2009-01-01

    Historically both sensitivity level 3 and sensitivity level 4 fluorescent penetrants have been used to perform NASA Standard Level inspections of aerospace hardware. In April 2008, NASA-STD-5009 established a requirement that only sensitivity level 4 penetrants were acceptable for inspections of NASA hardware. Having NASA contractors change existing processes or perform demonstration tests to certify sensitivity level 3 penetrants posed a potentially huge cost to the Agency. This study was conducted to directly compare the probability of detection sensitivity level 3 and level 4 penetrants using both Method A and Method D inspection processes. The study results strongly support the conclusion that sensitivity level 3 penetrants are acceptable for NASA Standard Level inspections

  16. Analysis of Endocrine Disrupting Pesticides by Capillary GC with Mass Spectrometric Detection

    PubMed Central

    Matisová, Eva; Hrouzková, Svetlana

    2012-01-01

    Endocrine disrupting chemicals, among them many pesticides, alter the normal functioning of the endocrine system of both wildlife and humans at very low concentration levels. Therefore, the importance of method development for their analysis in food and the environment is increasing. This also covers contributions in the field of ultra-trace analysis of multicomponent mixtures of organic pollutants in complex matrices. With this fact conventional capillary gas chromatography (CGC) and fast CGC with mass spectrometric detection (MS) has acquired a real importance in the analysis of endocrine disrupting pesticide (EDP) residues. This paper provides an overview of GC methods, including sample preparation steps, for analysis of EDPs in a variety of matrices at ultra-trace concentration levels. Emphasis is put on separation method, mode of MS detection and ionization and obtained limits of detection and quantification. Analysis time is one of the most important aspects that should be considered in the choice of analytical methods for routine analysis. Therefore, the benefits of developed fast GC methods are important. PMID:23202677

  17. Autonomous rock detection on mars through region contrast

    NASA Astrophysics Data System (ADS)

    Xiao, Xueming; Cui, Hutao; Yao, Meibao; Tian, Yang

    2017-08-01

    In this paper, we present a new autonomous rock detection approach through region contrast. Unlike current state-of-art pixel-level rock segmenting methods, new method deals with this issue in region level, which will significantly reduce the computational cost. Image is firstly splitted into homogeneous regions based on intensity information and spatial layout. Considering the high-water memory constraints of onboard flight processor, only low-level features, average intensity and variation of superpixel, are measured. Region contrast is derived as the integration of intensity contrast and smoothness measurement. Rocks are then segmented from the resulting contrast map by an adaptive threshold. Since the merely intensity-based method may cause false detection in background areas with different illuminations from surroundings, a more reliable method is further proposed by introducing spatial factor and background similarity to the region contrast. Spatial factor demonstrates the locality of contrast, while background similarity calculates the probability of each subregion belonging to background. Our method is efficient in dealing with large images and only few parameters are needed. Preliminary experimental results show that our algorithm outperforms edge-based methods in various grayscale rover images.

  18. Assessment of soil-gas and soil contamination at the Old Metal Workshop Hog Farm Area, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Caldwell, Andral W.; Falls, W. Fred; Guimaraes, Wladmir B.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    Soil gas and soil were assessed for contaminants at the Old Metal Workshop Hog Farm Area at Fort Gordon, Georgia, from October 2009 to September 2010. The assessment included delineating organic contaminants present in soil-gas and inorganic contaminants present in soil samples collected from the area estimated to be the Old Metal Workshop Hog Farm Area. This assessment was conducted to provide environmental contamination data to Fort Gordon personnel pursuant to requirements for the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. All soil-gas samplers contained total petroleum hydrocarbons above the method detection level. The highest total petroleum hydrocarbon mass detected was 121.32 micrograms in a soil-gas sampler from the western corner of the Old Metal Workshop Hog Farm Area along Sawmill Road. The highest undecane mass detected was 73.28 micrograms at the same location as the highest total petroleum hydrocarbon mass. Some soil-gas samplers detected toluene mass greater than the method detection level of 0.02 microgram; the highest detection of toluene mass was 0.07 microgram. Some soil-gas samplers were installed in areas of high-contaminant mass to assess for explosives and chemical agents. Explosives or chemical agents were not detected above their respective method detection levels for all soil-gas samplers installed. Inorganic concentrations in five soil samples collected did not exceed regional screening levels established by the U.S. Environmental Protection Agency. Barium concentrations, however, were up to eight times higher than the background concentrations reported in similar Coastal Plain sediments of South Carolina.

  19. Rapid determination of natural and synthetic hormones in biosolids and poultry manure by isotope dilution GC-MS/MS.

    PubMed

    Albero, Beatriz; Sánchez-Brunete, Consuelo; Miguel, Esther; Aznar, Ramón; Tadeo, José L

    2014-04-01

    The release of hormones into the environment due to land application of biosolids and manure is a cause of concern for their potential impacts. This paper presents the development of a rapid and sensitive method, based on extraction, for the analysis of 13 hormones in biosolids and poultry manure. A simultaneous derivatization of hydroxyl and ketone groups was carried out for the determination of hormones by GC–MS/MS. The method was validated in three matrices (sewage sludge, manure, and broiler litter). Recoveries from spiked samples at three concentration levels (50, 25, and 10 ng/g) ranged from 76 to 124% with relative SDs ≤ 16%. Method detection limits for the three matrices were in the range of 0.5–3.0 ng/g dry weight. The optimized method was applied to biosolid and poultry manure samples collected in Spain. Only seven of the 13 studied hormones were detected in the different samples. trans-Androsterone was detected at high levels (up to 3.1 μg/g in biosolid samples). Estrone and estradiol were the two hormones detected at higher levels in layer manure, whereas estrone and 4-androstene-3,17-dione presented the highest levels in broiler litter.

  20. Robust boundary detection of left ventricles on ultrasound images using ASM-level set method.

    PubMed

    Zhang, Yaonan; Gao, Yuan; Li, Hong; Teng, Yueyang; Kang, Yan

    2015-01-01

    Level set method has been widely used in medical image analysis, but it has difficulties when being used in the segmentation of left ventricular (LV) boundaries on echocardiography images because the boundaries are not very distinguish, and the signal-to-noise ratio of echocardiography images is not very high. In this paper, we introduce the Active Shape Model (ASM) into the traditional level set method to enforce shape constraints. It improves the accuracy of boundary detection and makes the evolution more efficient. The experiments conducted on the real cardiac ultrasound image sequences show a positive and promising result.

  1. Most Probable Number Rapid Viability PCR Method to Detect Viable Spores of Bacillus anthracis in Swab Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Letant, S E; Kane, S R; Murphy, G A

    2008-05-30

    This note presents a comparison of Most-Probable-Number Rapid Viability (MPN-RV) PCR and traditional culture methods for the quantification of Bacillus anthracis Sterne spores in macrofoam swabs generated by the Centers for Disease Control and Prevention (CDC) for a multi-center validation study aimed at testing environmental swab processing methods for recovery, detection, and quantification of viable B. anthracis spores from surfaces. Results show that spore numbers provided by the MPN RV-PCR method were in statistical agreement with the CDC conventional culture method for all three levels of spores tested (10{sup 4}, 10{sup 2}, and 10 spores) even in the presence ofmore » dirt. In addition to detecting low levels of spores in environmental conditions, the MPN RV-PCR method is specific, and compatible with automated high-throughput sample processing and analysis protocols.« less

  2. A method for detecting nonlinear determinism in normal and epileptic brain EEG signals.

    PubMed

    Meghdadi, Amir H; Fazel-Rezai, Reza; Aghakhani, Yahya

    2007-01-01

    A robust method of detecting determinism for short time series is proposed and applied to both healthy and epileptic EEG signals. The method provides a robust measure of determinism through characterizing the trajectories of the signal components which are obtained through singular value decomposition. Robustness of the method is shown by calculating proposed index of determinism at different levels of white and colored noise added to a simulated chaotic signal. The method is shown to be able to detect determinism at considerably high levels of additive noise. The method is then applied to both intracranial and scalp EEG recordings collected in different data sets for healthy and epileptic brain signals. The results show that for all of the studied EEG data sets there is enough evidence of determinism. The determinism is more significant for intracranial EEG recordings particularly during seizure activity.

  3. Detecting text in natural scenes with multi-level MSER and SWT

    NASA Astrophysics Data System (ADS)

    Lu, Tongwei; Liu, Renjun

    2018-04-01

    The detection of the characters in the natural scene is susceptible to factors such as complex background, variable viewing angle and diverse forms of language, which leads to poor detection results. Aiming at these problems, a new text detection method was proposed, which consisted of two main stages, candidate region extraction and text region detection. At first stage, the method used multiple scale transformations of original image and multiple thresholds of maximally stable extremal regions (MSER) to detect the text regions which could detect character regions comprehensively. At second stage, obtained SWT maps by using the stroke width transform (SWT) algorithm to compute the candidate regions, then using cascaded classifiers to propose non-text regions. The proposed method was evaluated on the standard benchmark datasets of ICDAR2011 and the datasets that we made our own data sets. The experiment results showed that the proposed method have greatly improved that compared to other text detection methods.

  4. Pitfalls in the detection of cholesterol in Huntington’s disease models

    PubMed Central

    Marullo, Manuela; Valenza, Marta; Leoni, Valerio; Caccia, Claudio; Scarlatti, Chiara; De Mario, Agnese; Zuccato, Chiara; Di Donato, Stefano; Carafoli, Ernesto; Cattaneo, Elena

    2012-01-01

    Background Abnormalities in brain cholesterol homeostasis have been reported in Huntington’s disease (HD), an adult-onset neurodegenerative disorder caused by an expansion in the number of CAG repeats in the huntingtin (HTT) gene. However, the results have been contradictory with respect to whether cholesterol levels increase or decrease in HD models. Biochemical and mass spectrometry methods show reduced levels of cholesterol precursors and cholesterol in HD cells and in the brains of several HD animal models. Abnormal brain cholesterol homeostasis was also inferred from studies in HD patients. In contrast, colorimetric and enzymatic methods indicate cholesterol accumulation in HD cells and tissues. Here we used several methods to investigate cholesterol levels in cultured cells in the presence or absence of mutant HTT protein. Results Colorimetric and enzymatic methods with low sensitivity gave variable results, whereas results from a sensitive analytical method, gas chromatography-mass spectrometry, were more reliable. Sample preparation, high cell density and cell clonality also influenced the detection of intracellular cholesterol. Conclusions Detection of cholesterol in HD samples by colorimetric and enzymatic assays should be supplemented by detection using more sensitive analytical methods. Care must be taken to prepare the sample appropriately. By evaluating lathosterol levels using isotopic dilution mass spectrometry, we confirmed reduced cholesterol biosynthesis in knock-in cells expressing the polyQ mutation in a constitutive or inducible manner. *Correspondence should be addressed to Elena Cattaneo: elena.cattaneo@unimi.it PMID:23145355

  5. Determination of anthelmintic drug residues in milk using ultra high performance liquid chromatography-tandem mass spectrometry with rapid polarity switching.

    PubMed

    Whelan, Michelle; Kinsella, Brian; Furey, Ambrose; Moloney, Mary; Cantwell, Helen; Lehotay, Steven J; Danaher, Martin

    2010-07-02

    A new UHPLC-MS/MS (ultra high performance liquid chromatography coupled to tandem mass spectrometry) method was developed and validated to detect 38 anthelmintic drug residues, consisting of benzimidazoles, avermectins and flukicides. A modified QuEChERS-type extraction method was developed with an added concentration step to detect most of the analytes at <1 microg kg(-1) levels in milk. Anthelmintic residues were extracted into acetonitrile using magnesium sulphate and sodium chloride to induce liquid-liquid partitioning followed by dispersive solid phase extraction for cleanup. The extract was concentrated into dimethyl sulphoxide, which was used as a keeper to ensure analytes remain in solution. Using rapid polarity switching in electrospray ionisation, a single injection was capable of detecting both positively and negatively charged ions in a 13 min run time. The method was validated at two levels: the unapproved use level and at the maximum residue level (MRL) according to Commission Decision (CD) 2002/657/EC criteria. The decision limit (CCalpha) of the method was in the range of 0.14-1.9 and 11-123 microg kg(-1) for drugs validated at unapproved and MRL levels, respectively. The performance of the method was successfully verified for benzimidazoles and levamisole by participating in a proficiency study.

  6. Microfluidic platform for multiplexed detection in single cells and methods thereof

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Meiye; Singh, Anup K.

    The present invention relates to a microfluidic device and platform configured to conduct multiplexed analysis within the device. In particular, the device allows multiple targets to be detected on a single-cell level. Also provided are methods of performing multiplexed analyses to detect one or more target nucleic acids, proteins, and post-translational modifications.

  7. Monoclonal antibodies to synthetic pyrethroids and method for detecting the same

    DOEpatents

    Stanker, Larry H.; Vanderlaan, Martin; Watkins, Bruce E.; Van Emon, Jeanette M.; Bigbee, Carolyn L.

    1992-01-01

    Methods are described for making specific monoclonal antibodies which may be used in a sensitive immunoassay for detection of synthetic pyrethroids in foods and environmental samples. Appropriate sample preparation and enzyme amplification of the immunoassay for this widely-used class of pesticides permits detection at low levels in laboratory and field tested samples.

  8. Monoclonal antibodies to synthetic pyrethroids and method for detecting the same

    DOEpatents

    Stanker, L.H.; Vanderlaan, M.; Watkins, B.E.; Van Emon, J.M.; Bigbee, C.L.

    1992-04-28

    Methods are described for making specific monoclonal antibodies which may be used in a sensitive immunoassay for detection of synthetic pyrethroids in foods and environmental samples. Appropriate sample preparation and enzyme amplification of the immunoassay for this widely-used class of pesticides permits detection at low levels in laboratory and field tested samples. 6 figs.

  9. The Trace Analysis of DEET in Water using an On-line Preconcentration Column and Liquid Chromatography with UV Photodiode Array Detection

    EPA Science Inventory

    A method for the detection of trace levels of N,N-diethyl-m-toluamide (DEET) in water is discussed. The method utilizes an on-line preconcentration column in series with high performance liquid chromatography (HPLC) and UV photodiode array detection. DEET, a common insect repel...

  10. Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

    PubMed

    Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin

    2017-06-01

    Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.

  11. The estimation method on diffusion spot energy concentration of the detection system

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Song, Zongxi; Liu, Feng; Dan, Lijun; Sun, Zhonghan; Du, Yunfei

    2016-09-01

    We propose a method to estimate the diffusion spot energy of the detection system. We do outdoor observation experiments in Xinglong Observatory, by using a detection system which diffusion spot energy concentration is estimated (the correlation coefficient is approximate 0.9926).The aperture of system is 300mm and limiting magnitude of system is 14.15Mv. Observation experiments show that the highest detecting magnitude of estimated system is 13.96Mv, and the average detecting magnitude of estimated system is about 13.5Mv. The results indicate that this method can be used to evaluate the energy diffusion spot concentration level of detection system efficiently.

  12. A Novel Method to Detect Early Colorectal Cancer Based on Chromosome Copy Number Variation in Plasma.

    PubMed

    Xu, Jun-Feng; Kang, Qian; Ma, Xing-Yong; Pan, Yuan-Ming; Yang, Lang; Jin, Peng; Wang, Xin; Li, Chen-Guang; Chen, Xiao-Chen; Wu, Chao; Jiao, Shao-Zhuo; Sheng, Jian-Qiu

    2018-01-01

    Colonoscopy screening has been accepted broadly to evaluate the risk and incidence of colorectal cancer (CRC) during health examination in outpatients. However, the intrusiveness, complexity and discomfort of colonoscopy may limit its application and the compliance of patients. Thus, more reliable and convenient diagnostic methods are necessary for CRC screening. Genome instability, especially copy-number variation (CNV), is a hallmark of cancer and has been proved to have potential in clinical application. We determined the diagnostic potential of chromosomal CNV at the arm level by whole-genome sequencing of CRC plasma samples (n = 32) and healthy controls (n = 38). Arm level CNV was determined and the consistence of arm-level CNV between plasma and tissue was further analyzed. Two methods including regular z score and trained Support Vector Machine (SVM) classifier were applied for detection of colorectal cancer. In plasma samples of CRC patients, the most frequent deletions were detected on chromosomes 6, 8p, 14q and 1p, and the most frequent amplifications occurred on chromosome 19, 5, 2, 9p and 20p. These arm-level alterations detected in plasma were also observed in tumor tissues. We showed that the specificity of regular z score analysis for the detection of colorectal cancer was 86.8% (33/38), whereas its sensitivity was only 56.3% (18/32). Applying a trained SVM classifier (n = 40 in trained group) as the standard to detect colorectal cancer relevance ratio in the test samples (n = 30), a sensitivity of 91.7% (11/12) and a specificity 88.9% (16/18) were finally reached. Furthermore, all five early CRC patients in stages I and II were successfully detected. Trained SVM classifier based on arm-level CNVs can be used as a promising method to screen early-stage CRC. © 2018 The Author(s). Published by S. Karger AG, Basel.

  13. Sampling and Pooling Methods for Capturing Herd Level Antibiotic Resistance in Swine Feces using qPCR and CFU Approaches

    PubMed Central

    Mellerup, Anders; Ståhl, Marie

    2015-01-01

    The aim of this article was to define the sampling level and method combination that captures antibiotic resistance at pig herd level utilizing qPCR antibiotic resistance gene quantification and culture-based quantification of antibiotic resistant coliform indicator bacteria. Fourteen qPCR assays for commonly detected antibiotic resistance genes were developed, and used to quantify antibiotic resistance genes in total DNA from swine fecal samples that were obtained using different sampling and pooling methods. In parallel, the number of antibiotic resistant coliform indicator bacteria was determined in the same swine fecal samples. The results showed that the qPCR assays were capable of detecting differences in antibiotic resistance levels in individual animals that the coliform bacteria colony forming units (CFU) could not. Also, the qPCR assays more accurately quantified antibiotic resistance genes when comparing individual sampling and pooling methods. qPCR on pooled samples was found to be a good representative for the general resistance level in a pig herd compared to the coliform CFU counts. It had significantly reduced relative standard deviations compared to coliform CFU counts in the same samples, and therefore differences in antibiotic resistance levels between samples were more readily detected. To our knowledge, this is the first study to describe sampling and pooling methods for qPCR quantification of antibiotic resistance genes in total DNA extracted from swine feces. PMID:26114765

  14. A multilevel-ROI-features-based machine learning method for detection of morphometric biomarkers in Parkinson's disease.

    PubMed

    Peng, Bo; Wang, Suhong; Zhou, Zhiyong; Liu, Yan; Tong, Baotong; Zhang, Tao; Dai, Yakang

    2017-06-09

    Machine learning methods have been widely used in recent years for detection of neuroimaging biomarkers in regions of interest (ROIs) and assisting diagnosis of neurodegenerative diseases. The innovation of this study is to use multilevel-ROI-features-based machine learning method to detect sensitive morphometric biomarkers in Parkinson's disease (PD). Specifically, the low-level ROI features (gray matter volume, cortical thickness, etc.) and high-level correlative features (connectivity between ROIs) are integrated to construct the multilevel ROI features. Filter- and wrapper- based feature selection method and multi-kernel support vector machine (SVM) are used in the classification algorithm. T1-weighted brain magnetic resonance (MR) images of 69 PD patients and 103 normal controls from the Parkinson's Progression Markers Initiative (PPMI) dataset are included in the study. The machine learning method performs well in classification between PD patients and normal controls with an accuracy of 85.78%, a specificity of 87.79%, and a sensitivity of 87.64%. The most sensitive biomarkers between PD patients and normal controls are mainly distributed in frontal lobe, parental lobe, limbic lobe, temporal lobe, and central region. The classification performance of our method with multilevel ROI features is significantly improved comparing with other classification methods using single-level features. The proposed method shows promising identification ability for detecting morphometric biomarkers in PD, thus confirming the potentiality of our method in assisting diagnosis of the disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Chemical sensing thresholds for mine detection dogs

    NASA Astrophysics Data System (ADS)

    Phelan, James M.; Barnett, James L.

    2002-08-01

    Mine detection dogs have been found to be an effective method to locate buried landmines. The capabilities of the canine olfaction method are from a complex combination of training and inherent capacity of the dog for odor detection. The purpose of this effort was to explore the detection thresholds of a limited group of dogs that were trained specifically for landmine detection. Soils were contaminated with TNT and 2,4-DNT to develop chemical vapor standards to present to the dogs. Soils contained ultra trace levels of TNT and DNT, which produce extremely low vapor levels. Three groups of dogs were presented the headspace vapors from the contaminated soils in work environments for each dog group. One positive sample was placed among several that contained clean soils and, the location and vapor source (strength, type) was frequently changed. The detection thresholds for the dogs were determined from measured and extrapolated dilution of soil chemical residues and, estimated soil vapor values using phase partitioning relationships. The results showed significant variances in dog sensing thresholds, where some dogs could sense the lowest levels and others had trouble with even the highest source. The remarkable ultra-trace levels detectable by the dogs are consistent with the ultra-trace chemical residues derived from buried landmines; however, poor performance may go unnoticed without periodic challenge tests at levels consistent with performance requirements.

  16. Dry-Enzyme Test For Gaseous Chemicals

    NASA Technical Reports Server (NTRS)

    Barzana, Eduardo; Karel, Marcus; Klibanov, Alexander

    1990-01-01

    Simple, dry-chemical test detects ethanol in human breath. Method of test also adapted to detection of such toxic chemicals as formaldehyde in airstreams. Used qualitatively to detect chemical compounds above present level; for example, ethanol above legal level for driving. Also used to indicate quantitatively concentrations of compounds. Involves dry enzyme and color indicator. Adapted to detect any gaseous compound transformed by enzymes to produce change evident to human eye or to instrument.

  17. A Comparison of the Capability of Sensitivity Level 3 and Sensitivity Level 4 Fluorescent Penetrants to Detect Fatigue Cracks in Various Metals

    NASA Technical Reports Server (NTRS)

    Parker, Bradford H.

    2011-01-01

    In April 2008, NASA-STD-5009 established a requirement that only sensitivity level 4 penetrants are acceptable for NASA Standard Level liquid penetrant inspections. Having NASA contractors change existing processes or perform demonstration tests to certify sensitivity level 3 penetrants posed a potentially huge cost to the Agency. This study was conducted to directly compare the probability of detection (POD) of sensitivity level 3 and level 4 penetrants using both Method A and Method D inspection processes. POD demonstration tests were performed on 6061-Al, Haynes 188 and Ti-6Al-4V crack panel sets. The study results strongly support the conclusion that sensitivity level 3 penetrants are acceptable for NASA Standard Level inspections.

  18. Detecting and treating breast cancer resistance to EGFR inhibitors

    DOEpatents

    Moonlee, Sun-Young; Bissell, Mina J.; Furuta, Saori; Meier, Roland; Kenny, Paraic A.

    2016-04-05

    The application describes therapeutic compositions and methods for treating cancer. For example, therapeutic compositions and methods related to inhibition of FAM83A (family with sequence similarity 83) are provided. The application also describes methods for diagnosing cancer resistance to EGFR inhibitors. For example, a method of diagnosing cancer resistance to EGFR inhibitors by detecting increased FAM83A levels is described.

  19. Low level vapor verification of monomethyl hydrazine

    NASA Technical Reports Server (NTRS)

    Mehta, Narinder

    1990-01-01

    The vapor scrubbing system and the coulometric test procedure for the low level vapor verification of monomethyl hydrazine (MMH) are evaluated. Experimental data on precision, efficiency of the scrubbing liquid, instrument response, detection and reliable quantitation limits, stability of the vapor scrubbed solution, and interference were obtained to assess the applicability of the method for the low ppb level detection of the analyte vapor in air. The results indicated that the analyte vapor scrubbing system and the coulometric test procedure can be utilized for the quantitative detection of low ppb level vapor of MMH in air.

  20. Methylated site display (MSD)-AFLP, a sensitive and affordable method for analysis of CpG methylation profiles.

    PubMed

    Aiba, Toshiki; Saito, Toshiyuki; Hayashi, Akiko; Sato, Shinji; Yunokawa, Harunobu; Maruyama, Toru; Fujibuchi, Wataru; Kurita, Hisaka; Tohyama, Chiharu; Ohsako, Seiichiroh

    2017-03-09

    It has been pointed out that environmental factors or chemicals can cause diseases that are developmental in origin. To detect abnormal epigenetic alterations in DNA methylation, convenient and cost-effective methods are required for such research, in which multiple samples are processed simultaneously. We here present methylated site display (MSD), a unique technique for the preparation of DNA libraries. By combining it with amplified fragment length polymorphism (AFLP) analysis, we developed a new method, MSD-AFLP. Methylated site display libraries consist of only DNAs derived from DNA fragments that are CpG methylated at the 5' end in the original genomic DNA sample. To test the effectiveness of this method, CpG methylation levels in liver, kidney, and hippocampal tissues of mice were compared to examine if MSD-AFLP can detect subtle differences in the levels of tissue-specific differentially methylated CpGs. As a result, many CpG sites suspected to be tissue-specific differentially methylated were detected. Nucleotide sequences adjacent to these methyl-CpG sites were identified and we determined the methylation level by methylation-sensitive restriction endonuclease (MSRE)-PCR analysis to confirm the accuracy of AFLP analysis. The differences of the methylation level among tissues were almost identical among these methods. By MSD-AFLP analysis, we detected many CpGs showing less than 5% statistically significant tissue-specific difference and less than 10% degree of variability. Additionally, MSD-AFLP analysis could be used to identify CpG methylation sites in other organisms including humans. MSD-AFLP analysis can potentially be used to measure slight changes in CpG methylation level. Regarding the remarkable precision, sensitivity, and throughput of MSD-AFLP analysis studies, this method will be advantageous in a variety of epigenetics-based research.

  1. Advancing the detection of steady-state visual evoked potentials in brain-computer interfaces

    NASA Astrophysics Data System (ADS)

    Abu-Alqumsan, Mohammad; Peer, Angelika

    2016-06-01

    Objective. Spatial filtering has proved to be a powerful pre-processing step in detection of steady-state visual evoked potentials and boosted typical detection rates both in offline analysis and online SSVEP-based brain-computer interface applications. State-of-the-art detection methods and the spatial filters used thereby share many common foundations as they all build upon the second order statistics of the acquired Electroencephalographic (EEG) data, that is, its spatial autocovariance and cross-covariance with what is assumed to be a pure SSVEP response. The present study aims at highlighting the similarities and differences between these methods. Approach. We consider the canonical correlation analysis (CCA) method as a basis for the theoretical and empirical (with real EEG data) analysis of the state-of-the-art detection methods and the spatial filters used thereby. We build upon the findings of this analysis and prior research and propose a new detection method (CVARS) that combines the power of the canonical variates and that of the autoregressive spectral analysis in estimating the signal and noise power levels. Main results. We found that the multivariate synchronization index method and the maximum contrast combination method are variations of the CCA method. All three methods were found to provide relatively unreliable detections in low signal-to-noise ratio (SNR) regimes. CVARS and the minimum energy combination methods were found to provide better estimates for different SNR levels. Significance. Our theoretical and empirical results demonstrate that the proposed CVARS method outperforms other state-of-the-art detection methods when used in an unsupervised fashion. Furthermore, when used in a supervised fashion, a linear classifier learned from a short training session is able to estimate the hidden user intention, including the idle state (when the user is not attending to any stimulus), rapidly, accurately and reliably.

  2. New approach for monitoring fish stress: A novel enzyme-functionalized label-free immunosensor system for detecting cortisol levels in fish.

    PubMed

    Wu, Haiyun; Ohnuki, Hitoshi; Ota, Shirei; Murata, Masataka; Yoshiura, Yasutoshi; Endo, Hideaki

    2017-07-15

    Fishes display a wide variation in their physiological responses to stress, which is clearly evident in the plasma corticosteroid changes, chiefly cortisol levels in fish. As a well-known indicator of fish stress, a simple and rapid method for detecting cortisol changes especially sudden increases is desired. In this study, we describe an enzyme-functionalized label-free immunosensor system for detecting fish cortisol levels. Detection of cortisol using amperometry was achieved by immobilizing both anti-cortisol antibody (selective detection of cortisol) and glucose oxidase (signal amplification and non-toxic measurement) on an Au electrode surface with a self-assembled monolayer. This system is based on the maximum glucose oxidation output current change induced by the generation of a non-conductive antigen-antibody complex, which depends on the levels of cortisol in the sample. The immunosensor responded to cortisol levels with a linear decrease in the current in the range of 1.25-200ngml -1 (R=0.964). Since the dynamic range of the sensor can cover the normal range of plasma cortisol in fish, the samples obtained from the fish did not need to be diluted. Further, electrochemical measurement of one sample required only ~30min. The sensor system was applied to determine the cortisol levels in plasma sampled from Nile tilapia (Oreochromis niloticus), which were then compared with levels of the same samples determined using the conventional method (ELISA). Values determined using both methods were well correlated. These findings suggest that the proposed label-free immunosensor could be useful for rapid and convenient analysis of cortisol levels in fish without sample dilution. We also believe that the proposed system could be integrated in a miniaturized potentiostat for point-of-care cortisol detection and useful as a portable diagnostic in fish farms in the future. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Intensity and Compactness Enabled Saliency Estimation for Leakage Detection in Diabetic and Malarial Retinopathy.

    PubMed

    Zhao, Yitian; Zheng, Yalin; Liu, Yonghuai; Yang, Jian; Zhao, Yifan; Chen, Duanduan; Wang, Yongtian

    2017-01-01

    Leakage in retinal angiography currently is a key feature for confirming the activities of lesions in the management of a wide range of retinal diseases, such as diabetic maculopathy and paediatric malarial retinopathy. This paper proposes a new saliency-based method for the detection of leakage in fluorescein angiography. A superpixel approach is firstly employed to divide the image into meaningful patches (or superpixels) at different levels. Two saliency cues, intensity and compactness, are then proposed for the estimation of the saliency map of each individual superpixel at each level. The saliency maps at different levels over the same cues are fused using an averaging operator. The two saliency maps over different cues are fused using a pixel-wise multiplication operator. Leaking regions are finally detected by thresholding the saliency map followed by a graph-cut segmentation. The proposed method has been validated using the only two publicly available datasets: one for malarial retinopathy and the other for diabetic retinopathy. The experimental results show that it outperforms one of the latest competitors and performs as well as a human expert for leakage detection and outperforms several state-of-the-art methods for saliency detection.

  4. Deoxyribonucleic Acid Probes Analyses for the Detection of Periodontal Pathogens.

    PubMed

    Al Yahfoufi, Zoubeida; Hadchiti, Wahib; Berberi, Antoine

    2015-09-01

    In clinical microbiology several techniques have been used to identify bacteria. Recently, Deoxyribonucleic acid (DNA)-based techniques have been introduced to detect human microbial pathogens in periodontal diseases. Deoxyribonucleic acid probes can detect bacteria at a very low level if we compared with the culture methods. These probes have shown rapid and cost-effective microbial diagnosis, good sensitivity and specificity for some periodontal pathogens in cases of severe periodontitis. Eighty-five patients were recruited for the study. Twenty-one subjects ranging between 22 and 48 years of age fulfilled the inclusion and exclusion criteria. Seventy-eight samples became available for DNA probe analysis from the deepest pockets in each quadrant. All 21 patients showed positive results for Prevotella intermedia; also, Prevotella gingivalis was identified in 19 subjects, Aggregatibacter actinomycetemcomitans in 6 subjects. P. intermedia was diagnosed positive in 82% of the subgingival samples taken, 79% for P. gingivalis, and 23% for A. actinomycetemcomitans. This study shows a high frequency of putative periodontal pathogens by using DNA probe technology, which is semi-quantitative in this study. Deoxyribonucleic acid probes can detect bacteria at very low level about 10(3) which is below the detection level of culture methods. The detection threshold of cultural methods. The three types of bacteria can be detected rapidly with high sensitivity by using the DNA probe by general practitioners, and thus can help in the diagnosis process and the treatment.

  5. Automatic image orientation detection via confidence-based integration of low-level and semantic cues.

    PubMed

    Luo, Jiebo; Boutell, Matthew

    2005-05-01

    Automatic image orientation detection for natural images is a useful, yet challenging research topic. Humans use scene context and semantic object recognition to identify the correct image orientation. However, it is difficult for a computer to perform the task in the same way because current object recognition algorithms are extremely limited in their scope and robustness. As a result, existing orientation detection methods were built upon low-level vision features such as spatial distributions of color and texture. Discrepant detection rates have been reported for these methods in the literature. We have developed a probabilistic approach to image orientation detection via confidence-based integration of low-level and semantic cues within a Bayesian framework. Our current accuracy is 90 percent for unconstrained consumer photos, impressive given the findings of a psychophysical study conducted recently. The proposed framework is an attempt to bridge the gap between computer and human vision systems and is applicable to other problems involving semantic scene content understanding.

  6. Differentiation of Volatile Profiles from Stockpiled Almonds at Varying Relative Humidity Levels Using Benchtop and Portable GC-MS.

    PubMed

    Beck, John J; Willett, Denis S; Gee, Wai S; Mahoney, Noreen E; Higbee, Bradley S

    2016-12-14

    Contamination by aflatoxin, a toxic metabolite produced by Aspergillus fungi ubiquitous in California almond and pistachio orchards, results in millions of dollars of lost product annually. Current detection of aflatoxin relies on destructive, expensive, and time-intensive laboratory-based methods. To explore an alternative method for the detection of general fungal growth, volatile emission profiles of almonds at varying humidities were sampled using both static SPME and dynamic needle-trap SPE followed by benchtop and portable GC-MS analysis. Despite the portable SPE/GC-MS system detecting fewer volatiles than the benchtop system, both systems resolved humidity treatments and identified potential fungal biomarkers at extremely low water activity levels. This ability to resolve humidity levels suggests that volatile profiles from germinating fungal spores could be used to create an early warning, nondestructive, portable detection system of fungal growth.

  7. Mini-column assay for rapid detection of malachite green in fish.

    PubMed

    Shalaby, Ali R; Emam, Wafaa H; Anwar, Mervat M

    2017-07-01

    A simple, rapid and economical mini-column method for detecting malachite green (MG) residue in fish was developed. The method used a column with 2mm ID that was tightly packed with silica gel followed by alumina. Detection of MG was performed by viewing the developed mini-column at visible light by naked eye; where MG was seen as compact green band at the confluence of the silica gel layer with alumina layer. The limit of detection of the assay was 2ng which conform the minimum required performance limit (MRPL). Evaluation utility of the method indicated that all blank and spiked samples at levels below MRPL were assessed as accepted. The intensity of the green band increased whenever MG level in the extract increased; indicated that suggested mini-column technique could be used for semi-quantitative determination of MG in fish samples. The method can be used to select the questionable samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Evaluation of VIDAS UP Listeria assay (LPT) for the detection of Listeria in a variety of foods and environmental surfaces: First Action 2013.10.

    PubMed

    Crowley, Erin; Bird, Patrick; Flannery, Jonathan; Benzinger, M Joseph; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Bastin, Ben; Bedinghaus, Paige; Judd, William; Hoang, Thao; Agin, James; Goins, David; Johnson, Ronald L

    2014-01-01

    The VIDAS UP Listeria (LPT) is an automated rapid screening enzyme phage-ligand based assay for the detection of Listeria species in human food products and environmental samples. The VIDAS LPT method was compared in a multi-laboratory collaborative study to AOAC Official Method 993.12 Listeria monocytogenes in Milk and Dairy Products reference method following current AOAC guidelines. A total of 14 laboratories participated, representing government and industry, throughout the United States. One matrix, queso fresco (soft Mexican cheese), was analyzed using two different test portion sizes, 25 and 125 g. Samples representing each test portion size were artificially contaminated with Listeria species at three levels, an uninoculated control level [0 colony-forming units (CFU)/test portion], a low-inoculum level (0.2-2 CFU/test portion), and a high-inoculum level (2-5 CFU/test portion). For this evaluation, 1800 unpaired replicate test portions were analyzed by either the VIDAS LPT or AOAC 993.12. Each inoculation level was analyzed using the Probability of Detection (POD) statistical model. For the low-level inoculated test portions, difference in collaborator POD (dLPOD) values of 0.01, (-0.10, 0.13), with 95% confidence intervals, were obtained for both 25 and 125 g test portions. The range of the confidence intervals for dLPOD values for both the 25 and 125 g test portions contains the point 0.0 indicating no statistically significant difference in the number of positive samples detected between the VIDAS LPT and the AOAC methods. In addition to Oxford agar, VIDAS LPT test portions were confirmed using Agar Listeria Ottavani and Agosti (ALOA), a proprietary chromogenic agar for the identification and differentiation of L. monocytogenes and Listeria species. No differences were observed between the two selective agars. The VIDAS LPT method, with the optional ALOA agar confirmation method, was adopted as Official First Action status for the detection of Listeria species in a variety of foods and environmental samples.

  9. Faint Debris Detection by Particle Based Track-Before-Detect Method

    NASA Astrophysics Data System (ADS)

    Uetsuhara, M.; Ikoma, N.

    2014-09-01

    This study proposes a particle method to detect faint debris, which is hardly seen in single frame, from an image sequence based on the concept of track-before-detect (TBD). The most widely used detection method is detect-before-track (DBT), which firstly detects signals of targets from single frame by distinguishing difference of intensity between foreground and background then associate the signals for each target between frames. DBT is capable of tracking bright targets but limited. DBT is necessary to consider presence of false signals and is difficult to recover from false association. On the other hand, TBD methods try to track targets without explicitly detecting the signals followed by evaluation of goodness of each track and obtaining detection results. TBD has an advantage over DBT in detecting weak signals around background level in single frame. However, conventional TBD methods for debris detection apply brute-force search over candidate tracks then manually select true one from the candidates. To reduce those significant drawbacks of brute-force search and not-fully automated process, this study proposes a faint debris detection algorithm by a particle based TBD method consisting of sequential update of target state and heuristic search of initial state. The state consists of position, velocity direction and magnitude, and size of debris over the image at a single frame. The sequential update process is implemented by a particle filter (PF). PF is an optimal filtering technique that requires initial distribution of target state as a prior knowledge. An evolutional algorithm (EA) is utilized to search the initial distribution. The EA iteratively applies propagation and likelihood evaluation of particles for the same image sequences and resulting set of particles is used as an initial distribution of PF. This paper describes the algorithm of the proposed faint debris detection method. The algorithm demonstrates performance on image sequences acquired during observation campaigns dedicated to GEO breakup fragments, which would contain a sufficient number of faint debris images. The results indicate the proposed method is capable of tracking faint debris with moderate computational costs at operational level.

  10. Evaluation of PCR detection of Salmonella in alfalfa sprouts and spent irrigation water collected during sprouting of naturally contaminated seed.

    PubMed

    Maks, Nicole; Fu, Tong-Jen

    2013-02-01

    This study evaluated the efficacy of a PCR-based system (DuPont Qualicon BAX) for detection of Salmonella in sprouts and spent irrigation water collected during sprouting of seeds naturally contaminated with Salmonella. Alfalfa seeds were grown in Mason jars at 20 and 30°C for 3 days. Levels of Salmonella present in the water and sprouts were determined by most-probable-number (MPN) analysis. Background microflora levels were also determined. Samples of spent irrigation water and sprouts were enriched overnight individually in tetrathionate broth and in buffered peptone water with novobiocin at 42°C and then run in the BAX system. Samples were also enriched according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA BAM) method for Salmonella as a comparison. Salmonella levels were lower at 20°C compared with 30°C for some trials, and background microflora levels ranged from 10(7) to 10(8) CFU/g or ml at 20°C and 10(8) to 10(9) CFU/g or ml at 30°C. In trials with a Salmonella level >1.1 MPN/g or ml, both the BAX and FDA BAM methods were able to detect Salmonella in all samples. In trials with lower levels (0.21 MPN/g or ml or lower) of Salmonella, BAX was able to detect more positive samples than FDA BAM. For one trial with <0.003 MPN/g or ml of Salmonella, the presence of the pathogen was not indicated by either the BAX or the FDA BAM method. The results suggest that PCR detected low levels of Salmonella in sprouts or spent irrigation water collected from sprouting of naturally contaminated seeds.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belinsky, Steven A; Palmisano, William A

    A molecular marker-based method for monitoring and detecting cancer in humans. Aberrant methylation of gene promoters is a marker for cancer risk in humans. A two-stage, or "nested" polymerase chain reaction method is disclosed for detecting methylated DNA sequences at sufficiently high levels of sensitivity to permit cancer screening in biological fluid samples, such as sputum, obtained non-invasively. The method is for detecting the aberrant methylation of the p16 gene, O 6-methylguanine-DNA methyltransferase gene, Death-associated protein kinase gene, RAS-associated family 1 gene, or other gene promoters. The method offers a potentially powerful approach to population-based screening for the detection ofmore » lung and other cancers.« less

  12. Study on Calculation of Liquid Level And Storage of Tanks for LNG-fueled Vessels

    NASA Astrophysics Data System (ADS)

    Li, Kun; Wang, Guoqing; Liu, Chang

    2018-01-01

    As the ongoing development of the application of LNG as a clean energy in waterborne transport industry, the fleet scale of LNG-fueled vessels enlarged and the safety operation has attracted more attention in the industry. Especially the accurate detection of liquid level of LNG tanks is regarded as an important issue to ensure a safe and stable operation of LNG-fueled ships and a key parameter to keep the proper functioning of marine fuel storage system, supply system and safety control system. At present, detection of LNG tank liquid level mainly adopts differential pressure detection method. Liquid level condition could be found from the liquid level reference tables. However in practice, since LNG-fueled vessels are generally not in a stationary state, liquid state within the LNG tanks will constantly change, the detection of storage of tanks only by reference to the tables will cause deviation to some extent. By analyzing the temperature under different pressure, the effects of temperature change on density and volume integration calculation, a method of calculating the liquid level and storage of LNG tanks is put forward making the calculation of liquid level and actual storage of LNG tanks more accurately and providing a more reliable basis for the calculation of energy consumption level and operation economy for LNG-fueled vessels.

  13. Proposal and Implementation of a Robust Sensing Method for DVB-T Signal

    NASA Astrophysics Data System (ADS)

    Song, Chunyi; Rahman, Mohammad Azizur; Harada, Hiroshi

    This paper proposes a sensing method for TV signals of DVB-T standard to realize effective TV White Space (TVWS) Communication. In the TVWS technology trial organized by the Infocomm Development Authority (iDA) of Singapore, with regard to the sensing level and sensing time, detecting DVB-T signal at the level of -120dBm over an 8MHz channel with a sensing time below 1 second is required. To fulfill such a strict sensing requirement, we propose a smart sensing method which combines feature detection and energy detection (CFED), and is also characterized by using dynamic threshold selection (DTS) based on a threshold table to improve sensing robustness to noise uncertainty. The DTS based CFED (DTS-CFED) is evaluated by computer simulations and is also implemented into a hardware sensing prototype. The results show that the DTS-CFED achieves a detection probability above 0.9 for a target false alarm probability of 0.1 for DVB-T signals at the level of -120dBm over an 8MHz channel with the sensing time equals to 0.1 second.

  14. A Field-Based Cleaning Protocol for Sampling Devices Used in Life-Detection Studies

    NASA Astrophysics Data System (ADS)

    Eigenbrode, Jennifer; Benning, Liane G.; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E. F.

    2009-06-01

    Analytical approaches to extant and extinct life detection involve molecular detection often at trace levels. Thus, removal of biological materials and other organic molecules from the surfaces of devices used for sampling is essential for ascertaining meaningful results. Organic decontamination to levels consistent with null values on life-detection instruments is particularly challenging at remote field locations where Mars analog field investigations are carried out. Here, we present a seven-step, multi-reagent decontamination method that can be applied to sampling devices while in the field. In situ lipopolysaccharide detection via low-level endotoxin assays and molecular detection via gas chromatography-mass spectrometry were used to test the effectiveness of the decontamination protocol for sampling of glacial ice with a coring device and for sampling of sediments with a rover scoop during deployment at Arctic Mars-analog sites in Svalbard, Norway. Our results indicate that the protocols and detection technique sufficiently remove and detect low levels of molecular constituents necessary for life-detection tests.

  15. A field-based cleaning protocol for sampling devices used in life-detection studies.

    PubMed

    Eigenbrode, Jennifer; Benning, Liane G; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E F

    2009-06-01

    Analytical approaches to extant and extinct life detection involve molecular detection often at trace levels. Thus, removal of biological materials and other organic molecules from the surfaces of devices used for sampling is essential for ascertaining meaningful results. Organic decontamination to levels consistent with null values on life-detection instruments is particularly challenging at remote field locations where Mars analog field investigations are carried out. Here, we present a seven-step, multi-reagent decontamination method that can be applied to sampling devices while in the field. In situ lipopolysaccharide detection via low-level endotoxin assays and molecular detection via gas chromatography-mass spectrometry were used to test the effectiveness of the decontamination protocol for sampling of glacial ice with a coring device and for sampling of sediments with a rover scoop during deployment at Arctic Mars-analog sites in Svalbard, Norway. Our results indicate that the protocols and detection technique sufficiently remove and detect low levels of molecular constituents necessary for life-detection tests.

  16. A Method for the Minimization of Competition Bias in Signal Detection from Spontaneous Reporting Databases.

    PubMed

    Arnaud, Mickael; Salvo, Francesco; Ahmed, Ismaïl; Robinson, Philip; Moore, Nicholas; Bégaud, Bernard; Tubert-Bitter, Pascale; Pariente, Antoine

    2016-03-01

    The two methods for minimizing competition bias in signal of disproportionate reporting (SDR) detection--masking factor (MF) and masking ratio (MR)--have focused on the strength of disproportionality for identifying competitors and have been tested using competitors at the drug level. The aim of this study was to develop a method that relies on identifying competitors by considering the proportion of reports of adverse events (AEs) that mention the drug class at an adequate level of drug grouping to increase sensitivity (Se) for SDR unmasking, and its comparison with MF and MR. Reports in the French spontaneous reporting database between 2000 and 2005 were selected. Five AEs were considered: myocardial infarction, pancreatitis, aplastic anemia, convulsions, and gastrointestinal bleeding; related reports were retrieved using standardized Medical Dictionary for Regulatory Activities (MedDRA(®)) queries. Potential competitors of AEs were identified using the developed method, i.e. Competition Index (ComIn), as well as MF and MR. All three methods were tested according to Anatomical Therapeutic Chemical (ATC) classification levels 2-5. For each AE, SDR detection was performed, first in the complete database, and second after removing reports mentioning competitors; SDRs only detected after the removal were unmasked. All unmasked SDRs were validated using the Summary of Product Characteristics, and constituted the reference dataset used for computing the performance for SDR unmasking (area under the curve [AUC], Se). Performance of the ComIn was highest when considering competitors at ATC level 3 (AUC: 62 %; Se: 52 %); similar results were obtained with MF and MR. The ComIn could greatly minimize the competition bias in SDR detection. Further study using a larger dataset is needed.

  17. Spoofing detection on facial images recognition using LBP and GLCM combination

    NASA Astrophysics Data System (ADS)

    Sthevanie, F.; Ramadhani, K. N.

    2018-03-01

    The challenge for the facial based security system is how to detect facial image falsification such as facial image spoofing. Spoofing occurs when someone try to pretend as a registered user to obtain illegal access and gain advantage from the protected system. This research implements facial image spoofing detection method by analyzing image texture. The proposed method for texture analysis combines the Local Binary Pattern (LBP) and Gray Level Co-occurrence Matrix (GLCM) method. The experimental results show that spoofing detection using LBP and GLCM combination achieves high detection rate compared to that of using only LBP feature or GLCM feature.

  18. Detection of License Plate using Sliding Window, Histogram of Oriented Gradient, and Support Vector Machines Method

    NASA Astrophysics Data System (ADS)

    Astawa, INGA; Gusti Ngurah Bagus Caturbawa, I.; Made Sajayasa, I.; Dwi Suta Atmaja, I. Made Ari

    2018-01-01

    The license plate recognition usually used as part of system such as parking system. License plate detection considered as the most important step in the license plate recognition system. We propose methods that can be used to detect the vehicle plate on mobile phone. In this paper, we used Sliding Window, Histogram of Oriented Gradient (HOG), and Support Vector Machines (SVM) method to license plate detection so it will increase the detection level even though the image is not in a good quality. The image proceed by Sliding Window method in order to find plate position. Feature extraction in every window movement had been done by HOG and SVM method. Good result had shown in this research, which is 96% of accuracy.

  19. Interlaboratory variability in screening for Bonamia ostreae, a protistan parasite of the European flat oyster Ostrea edulis.

    PubMed

    Flannery, Grace; Lynch, Sharon A; Longshaw, Matt; Stone, David; Martin, Paul; Ramilo, Andrea; Villalba, Antonio; Culloty, Sarah C

    2014-07-24

    The spread of the protozoan parasite Bonamia ostreae is of major concern to the European flat oyster Ostrea edulis industry. Many studies have looked at the sensitivity of individual methods available to screen for B. ostreae, but in this study, 3 separate laboratories examined 4 methods of diagnosis currently used routinely in laboratories: heart imprints, histology, polymerase chain reaction (PCR) and in situ hybridisation (ISH). The results were compared to estimate interlaboratory variability. Heart imprints and histology had the highest reproducibility amongst the 3 laboratories, with greatest agreement between detection of infected and uninfected individuals. PCR had the highest detection level in every laboratory. These positives were related to the presence of confirmed infections but also in unconfirmed infections, possibly due to the presence of traces of B. ostreae DNA in oysters where clinical infections were not observed. PCR, in combination with histology or ISH, provided the most reliable detection levels in every laboratory. Variation in results for PCR and ISH observed between laboratories may be due to the different protocols used by each laboratory for both methods. Overall, the findings from the 3 laboratories indicated that at least 2 methods, with fixed protocols, should be used for the accurate detection and determination of infection prevalence within a sample. This combination of methods would allow for a clearer and more precise diagnosis of B. ostreae, preventing further spread of the disease and providing more accurate detection levels and epidemiological information.

  20. Vision Sensor-Based Road Detection for Field Robot Navigation

    PubMed Central

    Lu, Keyu; Li, Jian; An, Xiangjing; He, Hangen

    2015-01-01

    Road detection is an essential component of field robot navigation systems. Vision sensors play an important role in road detection for their great potential in environmental perception. In this paper, we propose a hierarchical vision sensor-based method for robust road detection in challenging road scenes. More specifically, for a given road image captured by an on-board vision sensor, we introduce a multiple population genetic algorithm (MPGA)-based approach for efficient road vanishing point detection. Superpixel-level seeds are then selected in an unsupervised way using a clustering strategy. Then, according to the GrowCut framework, the seeds proliferate and iteratively try to occupy their neighbors. After convergence, the initial road segment is obtained. Finally, in order to achieve a globally-consistent road segment, the initial road segment is refined using the conditional random field (CRF) framework, which integrates high-level information into road detection. We perform several experiments to evaluate the common performance, scale sensitivity and noise sensitivity of the proposed method. The experimental results demonstrate that the proposed method exhibits high robustness compared to the state of the art. PMID:26610514

  1. [Establishment of enzyme-linked immunosorbent assay (ELISA) for measuring human urinary uromodulin and application of the method in patients with IgA nephropathy].

    PubMed

    Liu, Ying; Chen, Yu-qing; Zhou, Jing-jing; Han, Jia; Liang, Yu; Li, Xue-ying; Zhang, Hong

    2012-04-18

    To establish a method of enzyme-linked immunosorbent assay (ELISA) to measure urinary uromodulin and explore the urinary uromudulin level in IgA nephropathy. The rabbit anti-human uromodulin polyclonal antibodies were coated on plates to capture uromodulin and the mouse anti-human uromodulin monoclonal antibody was used as detecting antibody to set up ELISA procedure. The precision and repeatability of this ELISA method were evaluated, and then this method was compared with the commercialized Tamm-Horsfall Glycoprotein ELISA Kit by examining urinary uromodulin levels in 55 individuals. Finally, the urinary uromodulin level in 166 IgA nephropathy patients were detected as well as 48 normal controls with this established method. The detecting range of uromodulin was 0.78-12.5 μg/L by this method. The coefficient of variation within-run was 7.5%, and between-run of coefficient of variation was 7.9%. Correlation of this method and comercialized kit was good (r=0.615, P<0.001). The urinary uromodulin/urinary creatinine ratio in IgA nephropathy was significantly lower than that in normal controls. The established ELISA method is sensitive and repeatable, and can be used in further studies.

  2. Detection and diagnosis of colitis on computed tomography using deep convolutional neural networks.

    PubMed

    Liu, Jiamin; Wang, David; Lu, Le; Wei, Zhuoshi; Kim, Lauren; Turkbey, Evrim B; Sahiner, Berkman; Petrick, Nicholas A; Summers, Ronald M

    2017-09-01

    Colitis refers to inflammation of the inner lining of the colon that is frequently associated with infection and allergic reactions. In this paper, we propose deep convolutional neural networks methods for lesion-level colitis detection and a support vector machine (SVM) classifier for patient-level colitis diagnosis on routine abdominal CT scans. The recently developed Faster Region-based Convolutional Neural Network (Faster RCNN) is utilized for lesion-level colitis detection. For each 2D slice, rectangular region proposals are generated by region proposal networks (RPN). Then, each region proposal is jointly classified and refined by a softmax classifier and bounding-box regressor. Two convolutional neural networks, eight layers of ZF net and 16 layers of VGG net are compared for colitis detection. Finally, for each patient, the detections on all 2D slices are collected and a SVM classifier is applied to develop a patient-level diagnosis. We trained and evaluated our method with 80 colitis patients and 80 normal cases using 4 × 4-fold cross validation. For lesion-level colitis detection, with ZF net, the mean of average precisions (mAP) were 48.7% and 50.9% for RCNN and Faster RCNN, respectively. The detection system achieved sensitivities of 51.4% and 54.0% at two false positives per patient for RCNN and Faster RCNN, respectively. With VGG net, Faster RCNN increased the mAP to 56.9% and increased the sensitivity to 58.4% at two false positive per patient. For patient-level colitis diagnosis, with ZF net, the average areas under the ROC curve (AUC) were 0.978 ± 0.009 and 0.984 ± 0.008 for RCNN and Faster RCNN method, respectively. The difference was not statistically significant with P = 0.18. At the optimal operating point, the RCNN method correctly identified 90.4% (72.3/80) of the colitis patients and 94.0% (75.2/80) of normal cases. The sensitivity improved to 91.6% (73.3/80) and the specificity improved to 95.0% (76.0/80) for the Faster RCNN method. With VGG net, Faster RCNN increased the AUC to 0.986 ± 0.007 and increased the diagnosis sensitivity to 93.7% (75.0/80) and specificity was unchanged at 95.0% (76.0/80). Colitis detection and diagnosis by deep convolutional neural networks is accurate and promising for future clinical application. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  3. Developing Bayesian adaptive methods for estimating sensitivity thresholds (d′) in Yes-No and forced-choice tasks

    PubMed Central

    Lesmes, Luis A.; Lu, Zhong-Lin; Baek, Jongsoo; Tran, Nina; Dosher, Barbara A.; Albright, Thomas D.

    2015-01-01

    Motivated by Signal Detection Theory (SDT), we developed a family of novel adaptive methods that estimate the sensitivity threshold—the signal intensity corresponding to a pre-defined sensitivity level (d′ = 1)—in Yes-No (YN) and Forced-Choice (FC) detection tasks. Rather than focus stimulus sampling to estimate a single level of %Yes or %Correct, the current methods sample psychometric functions more broadly, to concurrently estimate sensitivity and decision factors, and thereby estimate thresholds that are independent of decision confounds. Developed for four tasks—(1) simple YN detection, (2) cued YN detection, which cues the observer's response state before each trial, (3) rated YN detection, which incorporates a Not Sure response, and (4) FC detection—the qYN and qFC methods yield sensitivity thresholds that are independent of the task's decision structure (YN or FC) and/or the observer's subjective response state. Results from simulation and psychophysics suggest that 25 trials (and sometimes less) are sufficient to estimate YN thresholds with reasonable precision (s.d. = 0.10–0.15 decimal log units), but more trials are needed for FC thresholds. When the same subjects were tested across tasks of simple, cued, rated, and FC detection, adaptive threshold estimates exhibited excellent agreement with the method of constant stimuli (MCS), and with each other. These YN adaptive methods deliver criterion-free thresholds that have previously been exclusive to FC methods. PMID:26300798

  4. Sensitivity and accuracy of DNA based methods used to describe aquatic communities for early detection of invasive fish species

    EPA Science Inventory

    For biomonitoring efforts aimed at early detection of aquatic invasive species (AIS), the ability to detect rare individuals is key and requires accurate species level identification to maintain a low occurrence probability of non-detection errors (failure to detect a present spe...

  5. A robust sub-pixel edge detection method of infrared image based on tremor-based retinal receptive field model

    NASA Astrophysics Data System (ADS)

    Gao, Kun; Yang, Hu; Chen, Xiaomei; Ni, Guoqiang

    2008-03-01

    Because of complex thermal objects in an infrared image, the prevalent image edge detection operators are often suitable for a certain scene and extract too wide edges sometimes. From a biological point of view, the image edge detection operators work reliably when assuming a convolution-based receptive field architecture. A DoG (Difference-of- Gaussians) model filter based on ON-center retinal ganglion cell receptive field architecture with artificial eye tremors introduced is proposed for the image contour detection. Aiming at the blurred edges of an infrared image, the subsequent orthogonal polynomial interpolation and sub-pixel level edge detection in rough edge pixel neighborhood is adopted to locate the foregoing rough edges in sub-pixel level. Numerical simulations show that this method can locate the target edge accurately and robustly.

  6. Anthropogenic constituents in shallow ground water in the Upper Illinois River Basin

    USGS Publications Warehouse

    Morrow, William S.

    2003-01-01

    The potential for anthropogenic effects on ground water is becoming of increasing concern as land throughout the Nation becomes more urbanized. The possible contamination of water resources by volatile organic compounds (VOCs), pesticides (including transformation products), and nitrate, from current urban land use and past agricultural land use, is of particular concern. As part of the U.S. Geological Survey's National Water-Quality Assessment program, water samples for analysis of VOCs, pesticides, and nitrate were collected from 43 wells in shallow (175 feet deep or less) ground water in glacial deposits overlying a major bedrock aquifer in recently urbanized areas in the Chicago, Ill. and Milwaukee, Wis. metropolitan counties.Constituents were reported using two reporting levels. For the laboratory reporting level, the risk of a false positive or false negative detection is less than or equal to 1 percent. For the information-rich method level, estimated concentrations are identified positively and are qualified to be present on the basis of quality-control criteria, but have a higher risk of false positive detections.VOCs were detected in 32 percent (12 of 38) of the well samples with 15 detections of 7 VOCs, based on laboratory reporting levels. Concentrations ranged from 0.03 (estimated) to 4.6 micrograms per liter (?g/L), with a median concentration of 0.13 ?g/L. Methyl tert-butyl ether (MTBE) and trichloromethane (chloroform) were the most common with detections in 10 percent (4 of 38) of the well samples. Using information-rich method reporting levels, VOCs were detected in 74 percent of the wells with 37 detections of 15 VOCs. Chloroform was most common with detections in 24 percent (9 of 38) of the well samples.Pesticides were detected in 62 percent (26 of 42) of the well samples with 83 detections of 20 pesticides, based on laboratory reporting levels for the respective constituent. Concentrations ranged from 0.003 (estimated) to 3.6 (estimated) ?g/L, with a median concentration of 0.06 ?g/L. Deethylatrazine was most common with detections in 43 percent (18 of 42) of the well samples. Using information-rich method reporting levels, pesticides were detected in 74 percent (31 of 42) of the well samples with 134 detections of 29 pesticides. Deethylatrazine was most common with detections in 45 percent (19 of 42) of the well samples.Nitrate concentrations ranged from less than 0.047 to 12.5 milligrams per liter (mg/L) with a median concentration of 0.068 mg/L. Nitrate concentrations were greater than 2 mg/L in 30 percent (13 of 43) of the wells sampled. Total VOC detections did not correlate well (less than Spearman Rank correlation value of plus or minus 0.10) with well depth, age, or dissolved oxygen. Total pesticide detections did correlate with dissolved oxygen and negatively correlated with well depth. Nitrate concentrations correlated with dissolved oxygen and apparent recharge date.No VOC or pesticide concentrations exceeded U.S. Environmental Protection Agency drinking-water standards and only one nitrate 2 Anthropogenic Constituents in Shallow Ground Water in the Upper Illinois River Basin detection exceeded the standards. However, of the 43 wells sampled for VOCs or pesticides using information-rich methods, or nitrate at laboratory reporting levels, 40 of 43 (93 percent) well samples had at least one detection of a VOC or pesticide, or a detection of nitrate above 2.0 mg/L. This result indicates that most of these wells are anthropogenically affected, but presently not at U.S. Environmental Protection Agency drinking-water regulation levels of concern. The wells sampled were not public drinking-water supplies; therefore, these wells were not subject to U.S. Environmental Protection Agency drinking-water regulations.

  7. [Determination of homocysteine level in plasma by high performance liquids chromatography with fluorescence detection].

    PubMed

    Da, Xu; Qian, Ling-Jia

    2005-08-01

    To establish a method for detection of plasma total homocysteine with HPLC. The chromatography analysis was carried out using a Symmetry Shield RP18. The mobile phase was sodium acetate (0.08 mol/L) and methanol (1%) and we utilized a HPLC system with fluorescence detection of plasma homocysteine derivatized from reaction with 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-F). The average recoveries were 95.8 - 100.8% and the relative standard deviations were 1.2-2.0%. The results showed it to be a rapid and accurate method for the determination of homocysteine level in plasma.

  8. Non-invasive glucose monitor

    NASA Technical Reports Server (NTRS)

    Lambert, James L. (Inventor); Borchert, Mark S. (Inventor)

    2001-01-01

    A non-invasive method for determining blood level of an analyte of interest, such as glucose, comprises: generating an excitation laser beam (e.g., at a wavelength of 700 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor in the anterior chamber is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated aqueous humor; and then determining the blood glucose level (or the level of another analyte of interest) for the subject from the Raman spectrum. Preferably, the detecting step is followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing method is also disclosed.

  9. Verification of spectrophotometric method for nitrate analysis in water samples

    NASA Astrophysics Data System (ADS)

    Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu

    2017-12-01

    The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.

  10. Molecular sieve sensors for selective detection at the nanogram level

    DOEpatents

    Bein, Thomas; Brown, Kelly D.; Frye, Gregory C.; Brinker, Charles J.

    1992-01-01

    The invention relates to a selective chemical sensor for selective detection of chemical entities even at the nanogram level. The invention further relates to methods of using the sensor. The sensor comprises: (a) a piezoelectric substrate capable of detecting mass changes resulting from adsorption of material thereon; and (b) a coating applied to the substrate, which selectively sorbs chemical entities of a size smaller than a preselected magnitude.

  11. Comparison between capillary electrophoresis and high performance liquid chromatography for detection and quantification of Hb constant spring [Hb CS; α142, Term→Gln (TAA>CAA IN α2)].

    PubMed

    Waneesorn, Jarurin; Panyasai, Sitthichai; Kongthai, Kanyakan; Singboottra, Panthong; Pornprasert, Sakorn

    2011-01-01

    Hb Constant Spring [Hb CS; α142, Term→Gln (TAA>CAA in α2)] is often missed by routine laboratory testing since its mRNA as well as gene product are unstable and presented at a low level in peripheral blood. This study aimed to analyze the efficacy of capillary electrophoresis (CE) and high performance liquid chromatography (HPLC) for detecting and quantifying Hb CS in 19 heterozygotes and 14 homozygotes with Hb CS as well as 10 Hb H-CS disease subjects who were detected by molecular analysis. In the CE electrophoregram, Hb CS was seen at zone 2 and was observed in all samples, while the chromatogram of Hb CS peaks was found in 26.32% heterozygotes, 42.86% homozygotes and 90% Hb H-CS disease subjects, respectively. In addition, the Hb CS levels in each group of subjects quantified by CE were significantly higher than those quantified by HPLC. Based on the CE method, the lowest Hb CS level was found in the heterozygotes, whereas the highest level was found in the Hb H-CS disease patients. Therefore, the CE method was superior to the HPLC method for detecting Hb CS. Furthermore, the level of Hb CS quantified by CE proved useful in screening heterozygotes and homozygotes with Hb CS as well as Hb H-CS disease.

  12. The determination of sulfite levels and its oxidation in plant leaves.

    PubMed

    Brychkova, Galina; Yarmolinsky, Dmitry; Fluhr, Robert; Sagi, Moshe

    2012-07-01

    Sulfur is the sixth most abundant element in life and an important building block of proteins and cellular metabolites. Plants like bacteria can synthesize their sulfur-containing biomolecules from sulfate, where sulfite is an intermediate of the sulfur assimilation pathway. Above a certain threshold SO(2)/sulfite is cytotoxic and is rapidly metabolized to avoid damage. However, the existing data show considerable differences in basal sulfite levels both between species and apparent discrepancies in measured levels in the same species. In order to resolve this question we employed a sulfite detection method using chicken sulfite oxidase and developed an independent enzymatic assay, based on the specific detection of sulfite by sulfite reductase and compared those measurements to a modified colorimetric fuchsin-based method, specific for sulfite detection. We show here that when properly used the sulfite levels detected by the three methods can yield identical results. Furthermore, to examine the capacity of the plant to detoxify sulfite we injected sub-lethal sulfite solutions (yet, several folds higher than the basal levels) into Arabidopsis and tomato leaves and monitored the excess sulfite turnover. Within 3h of sulfite injection, more than 80% of the injected sulfite in Arabidopsis and 91% in tomato were oxidized to sulfate, demonstrating the high capacity of the sulfite oxidation mechanism/s in plants. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. A SIMPLE HPLC METHOD FOR DETECTING CARBARYL AND 1-NAPHTHOL IN BIOLOGICAL TISSUES.

    EPA Science Inventory

    Carbamates are a class of pesticide used in both agricultural and residential applications. A simple HPLC method for detecting Carb and its metabolite 1-naphthol (Naph) in tissues was developed to try to correlate tissue levels of carbaryl (Carb) (a prototypical carbamate) with c...

  14. Development of a label-free immunosensor system for detecting plasma cortisol levels in fish.

    PubMed

    Wu, Haiyun; Ohnuki, Hitoshi; Hibi, Kyoko; Ren, Huifeng; Endo, Hideaki

    2016-02-01

    Fishes display a wide variation in their physiological responses to stress, which is clearly evident in the plasma corticosteroid changes, chiefly cortisol levels in fish. In the present study, we describe a novel label-free immunosensor for detecting plasma cortisol levels. The method is based on immunologic reactions and amperometric measurement using cyclic voltammetry. For the immobilization of the antibody on the surface of sensing electrode, we used a self-assembled monolayer of thiol-containing compounds. Using this electrode, we detect the CV signal change caused by the generation of antigen-antibody complex. The immunosensor showed a response to cortisol levels, and the anodic peak value linearly decreased with a correlation coefficient of 0.990 in diluted plasma. The specificity of the label-free immunosensor system was investigated using other steroid hormones, such as 17α, 20β-dihydroxy-4-pregnen-3-one, progesterone, estriol, estradiol, and testosterone. The specific detection of cortisol was suggested by a minimal change from -0.32 to 0.51 μA in the anodic peak value of the other steroid hormones. The sensor system was used to determine the plasma cortisol levels in Nile tilapia (Oreochromis niloticus), and the results were compared with those of the same samples determined using the conventional method (ELISA). A good correlation was obtained between values determined using both methods (correlation coefficient 0.993). These findings suggest that the proposed label-free immunosensor could be useful for rapid and convenient analysis of cortisol levels in fish plasma samples.

  15. DNA hybridization assay for detection of Salmonella in foods: collaborative study.

    PubMed

    Flowers, R S; Klatt, M J; Mozola, M A; Curiale, M S; Gabis, D A; Silliker, J H

    1987-01-01

    A collaborative study was performed in 11 laboratories to validate a DNA hybridization (DNAH) procedure for detection of Salmonella in foods. The DNAH procedure was compared to the standard culture method for detection of Salmonella in 6 foods: ground pepper, soy flour, dry whole egg, milk chocolate, nonfat dry milk, and raw deboned turkey. With the exception of turkey which was naturally contaminated, uninoculated and inoculated samples of each food group were analyzed. Results for the DNAH method were significantly better than for the standard culture method at the 5% probability level for the detection of Salmonella in turkey. There was no significant difference between the methods for the other 5 foods. The method has been adopted official first action.

  16. Automatic detection of articulation disorders in children with cleft lip and palate.

    PubMed

    Maier, Andreas; Hönig, Florian; Bocklet, Tobias; Nöth, Elmar; Stelzle, Florian; Nkenke, Emeka; Schuster, Maria

    2009-11-01

    Speech of children with cleft lip and palate (CLP) is sometimes still disordered even after adequate surgical and nonsurgical therapies. Such speech shows complex articulation disorders, which are usually assessed perceptually, consuming time and manpower. Hence, there is a need for an easy to apply and reliable automatic method. To create a reference for an automatic system, speech data of 58 children with CLP were assessed perceptually by experienced speech therapists for characteristic phonetic disorders at the phoneme level. The first part of the article aims to detect such characteristics by a semiautomatic procedure and the second to evaluate a fully automatic, thus simple, procedure. The methods are based on a combination of speech processing algorithms. The semiautomatic method achieves moderate to good agreement (kappa approximately 0.6) for the detection of all phonetic disorders. On a speaker level, significant correlations between the perceptual evaluation and the automatic system of 0.89 are obtained. The fully automatic system yields a correlation on the speaker level of 0.81 to the perceptual evaluation. This correlation is in the range of the inter-rater correlation of the listeners. The automatic speech evaluation is able to detect phonetic disorders at an experts'level without any additional human postprocessing.

  17. Trace level detection of analytes using artificial olfactometry

    NASA Technical Reports Server (NTRS)

    Wong, Bernard (Inventor); Munoz, Beth C. (Inventor); Lewis, Nathan S. (Inventor); Kelso, David M. (Inventor); Severin, Erik J. (Inventor)

    2001-01-01

    The present invention provides methods for detecting the presence of an analyte indicative of various medical conditions, including halitosis, periodontal disease and other diseases are also disclosed.

  18. Melamine detection in infant formula powder using near- and mid-infrared spectroscopy.

    PubMed

    Mauer, Lisa J; Chernyshova, Alona A; Hiatt, Ashley; Deering, Amanda; Davis, Reeta

    2009-05-27

    Near- and mid-infrared spectroscopy methods (NIR, FTIR-ATR, FTIR-DRIFT) were evaluated for the detection and quantification of melamine in infant formula powder. Partial least-squares (PLS) models were established for correlating spectral data to melamine concentration: R(2) > 0.99, RMSECV ≤ 0.9, and RPD ≥ 12. Factorization analysis of spectra was able to differentiate unadulterated infant formula powder from samples containing 1 ppm melamine with no misclassifications, a confidence level of 99.99%, and selectivity > 2. These nondestructive methods require little or no sample preparation. The NIR method has an assay time of 1 min, and a 2 min total time to detection. The FTIR methods require up to 5 min for melamine detection. Therefore, NIR and FTIR methods enable rapid detection of 1 ppm melamine in infant formula powder.

  19. Overview of MPLNET Version 3 Cloud Detection

    NASA Technical Reports Server (NTRS)

    Lewis, Jasper R.; Campbell, James; Welton, Ellsworth J.; Stewart, Sebastian A.; Haftings, Phillip

    2016-01-01

    The National Aeronautics and Space Administration Micro Pulse Lidar Network, version 3, cloud detection algorithm is described and differences relative to the previous version are highlighted. Clouds are identified from normalized level 1 signal profiles using two complementary methods. The first method considers vertical signal derivatives for detecting low-level clouds. The second method, which detects high-level clouds like cirrus, is based on signal uncertainties necessitated by the relatively low signal-to-noise ratio exhibited in the upper troposphere by eye-safe network instruments, especially during daytime. Furthermore, a multitemporal averaging scheme is used to improve cloud detection under conditions of a weak signal-to-noise ratio. Diurnal and seasonal cycles of cloud occurrence frequency based on one year of measurements at the Goddard Space Flight Center (Greenbelt, Maryland) site are compared for the new and previous versions. The largest differences, and perceived improvement, in detection occurs for high clouds (above 5 km, above MSL), which increase in occurrence by over 5%. There is also an increase in the detection of multilayered cloud profiles from 9% to 19%. Macrophysical properties and estimates of cloud optical depth are presented for a transparent cirrus dataset. However, the limit to which the cirrus cloud optical depth could be reliably estimated occurs between 0.5 and 0.8. A comparison using collocated CALIPSO measurements at the Goddard Space Flight Center and Singapore Micro Pulse Lidar Network (MPLNET) sites indicates improvements in cloud occurrence frequencies and layer heights.

  20. LC/DAD/ESI/MS method for the determination of imidacloprid, thiacloprid, and spinosad in olives and olive oil after field treatment.

    PubMed

    Angioni, Alberto; Porcu, Luciano; Pirisi, Filippo

    2011-10-26

    The behavior in the field and the transfer from olives to olive oil during the technological process of imidacloprid, thiacloprid, and spinosad were studied. The extraction method used was effective in extracting the analytes of interest, and no interfering peaks were detected in the chromatogram. The residue levels found in olives after treatment were 0.14, 0.04, and 0.30 mg/kg for imidacloprid, thiacloprid, and spinosad, respectively, far below the maximum residue levels (MRLs) set for these insecticides in EU. At the preharvest interval (PHI), no residue was detected for imidacloprid and thiacloprid, while spinosad showed a residue level of 0.04 mg/kg. The study of the effect of the technological process on pesticide transfer in olive oil showed that these insecticides tend to remain in the olive cake. The LC/DAD/ESI/MS method showed good performance with adequate recoveries ranging from 80 to 119% and good method limits of quantitation (LOQs) and of determination (LODs). No matrix effect was detected.

  1. [Comparative analysis of malaria detection ability of laboratories in Shanghai City from 2012 to 2015].

    PubMed

    Zhen-Yu, Wang; Li, Jiang; Yao-Guang, Zhang; Min, Zhu; Xiao-Ping, Zhang; Xiao-Jiang, Ma; Qian, Zhu; Yan-Yan, He; Shou-Fu, Jiang; Li, Cai

    2017-02-27

    To compare the application effects of three methods, namely microscopic examination, antigen detection (RDT) and nucleic acid test (PCR) in malaria detection between municipal and districts/counties centers for disease control and prevention in Shanghai, and analyze the malaria detection ability of the laboratories in Shanghai. The blood smears, whole blood samples, case review confirmation records and case data of malaria cases and suspected cases in Shanghai from 2012 to 2015 were collected by Shanghai Municipal Center for Disease Control and Prevention, and the detection results were analyzed and compared. A total of 212 samples with complete data were submitted by all districts (counties) in Shanghai from 2012 to 2015, the samples submitted by Jinshan Districts were the most (41.98%), and among the first diagnosis hospitals, those submitted by the tertiary hospitals were the most (82.07%). The submitted samples in the whole year were increased gradually from January to October. All the 212 samples were detected by three methods (the microscopic examination, RDT and PCR) in the laboratory of Shanghai Municipal Center for Disease Control and Prevention, and 167 were tested and confirmed comprehensively as positives, accounting for 78.77%, and 45 were confirmed as negatives, accounting for 21.23%. The samples were detected by the method of microscopy and domestic RDT in the laboratories of the centers for disease control and prevention at district/county level, totally 153 were tested as positives, accounting for 72.17%, 41 were unclassified, accounting for 19.34%, 53 were negative, accounting for 25.00%, and 6 were undetected, accounting for 2.83%. The coincidence of microscopic examination between the report hospitals and the centers for disease control and prevention at district/county level was 78.16%, and the coincidence between centers for disease control and prevention at district/county level and municipal level was 93.20%. The utilization rate of RDT in the laboratory of district/county level was 73.58%. The coincidence of RDT tests between those domestic and imported was 93.59%. Compared with the detection results by municipal center for disease control and prevention, 37 samples were misjudged by the laboratories of district/county level. Almost all (99.37%) of the confirmed malaria cases were imported overseas, including Africa (85.44%), Asia (13.92%) and America (0.63%). The surveillance after malaria elimination in Shanghai should be carried out by combining with different detection methods and resource integration.

  2. GMDD: a database of GMO detection methods.

    PubMed

    Dong, Wei; Yang, Litao; Shen, Kailin; Kim, Banghyun; Kleter, Gijs A; Marvin, Hans J P; Guo, Rong; Liang, Wanqi; Zhang, Dabing

    2008-06-04

    Since more than one hundred events of genetically modified organisms (GMOs) have been developed and approved for commercialization in global area, the GMO analysis methods are essential for the enforcement of GMO labelling regulations. Protein and nucleic acid-based detection techniques have been developed and utilized for GMOs identification and quantification. However, the information for harmonization and standardization of GMO analysis methods at global level is needed. GMO Detection method Database (GMDD) has collected almost all the previous developed and reported GMOs detection methods, which have been grouped by different strategies (screen-, gene-, construct-, and event-specific), and also provide a user-friendly search service of the detection methods by GMO event name, exogenous gene, or protein information, etc. In this database, users can obtain the sequences of exogenous integration, which will facilitate PCR primers and probes design. Also the information on endogenous genes, certified reference materials, reference molecules, and the validation status of developed methods is included in this database. Furthermore, registered users can also submit new detection methods and sequences to this database, and the newly submitted information will be released soon after being checked. GMDD contains comprehensive information of GMO detection methods. The database will make the GMOs analysis much easier.

  3. Long-term object tracking combined offline with online learning

    NASA Astrophysics Data System (ADS)

    Hu, Mengjie; Wei, Zhenzhong; Zhang, Guangjun

    2016-04-01

    We propose a simple yet effective method for long-term object tracking. Different from the traditional visual tracking method, which mainly depends on frame-to-frame correspondence, we combine high-level semantic information with low-level correspondences. Our framework is formulated in a confidence selection framework, which allows our system to recover from drift and partly deal with occlusion. To summarize, our algorithm can be roughly decomposed into an initialization stage and a tracking stage. In the initialization stage, an offline detector is trained to get the object appearance information at the category level, which is used for detecting the potential target and initializing the tracking stage. The tracking stage consists of three modules: the online tracking module, detection module, and decision module. A pretrained detector is used for maintaining drift of the online tracker, while the online tracker is used for filtering out false positive detections. A confidence selection mechanism is proposed to optimize the object location based on the online tracker and detection. If the target is lost, the pretrained detector is utilized to reinitialize the whole algorithm when the target is relocated. During experiments, we evaluate our method on several challenging video sequences, and it demonstrates huge improvement compared with detection and online tracking only.

  4. A longitudinal study of Campylobacter distribution in a turkey production chain

    PubMed Central

    Perko-Mäkelä, Päivikki; Isohanni, Pauliina; Katzav, Marianne; Lund, Marianne; Hänninen, Marja-Liisa; Lyhs, Ulrike

    2009-01-01

    Background Campylobacter is the most common cause of bacterial enteritis worldwide. Handling and eating of contaminated poultry meat has considered as one of the risk factors for human campylobacteriosis.Campylobacter contamination can occur at all stages of a poultry production cycle. The objective of this study was to determine the occurrence of Campylobacter during a complete turkey production cycle which lasts for 1,5 years of time. For detection of Campylobacter, a conventional culture method was compared with a PCR method. Campylobacter isolates from different types of samples have been identified to the species level by a multiplex PCR assay. Methods Samples (N = 456) were regularly collected from one turkey parent flock, the hatchery, six different commercial turkey farms and from 11 different stages at the slaughterhouse. For the detection of Campylobacter, a conventional culture and a PCR method were used. Campylobacter isolates (n = 143) were identified to species level by a multiplex PCR assay. Results No Campylobacter were detected in either the samples from the turkey parent flock or from hatchery samples using the culture method. PCR detected Campylobacter DNA in five faecal samples and one fluff and eggshell sample. Six flocks out of 12 commercial turkey flocks where found negative at the farm level but only two were negative at the slaughterhouse. Conclusion During the brooding period Campylobacter might have contact with the birds without spreading of the contamination within the flock. Contamination of working surfaces and equipment during slaughter of a Campylobacter positive turkey flock can persist and lead to possible contamination of negative flocks even after the end of the day's cleaning and desinfection. Reduction of contamination at farm by a high level of biosecurity control and hygiene may be one of the most efficient ways to reduce the amount of contaminated poultry meat in Finland. Due to the low numbers of Campylobacter in the Finnish turkey production chain, enrichment PCR seems to be the optimal detection method here. PMID:19348687

  5. Syndromic surveillance for health information system failures: a feasibility study

    PubMed Central

    Ong, Mei-Sing; Magrabi, Farah; Coiera, Enrico

    2013-01-01

    Objective To explore the applicability of a syndromic surveillance method to the early detection of health information technology (HIT) system failures. Methods A syndromic surveillance system was developed to monitor a laboratory information system at a tertiary hospital. Four indices were monitored: (1) total laboratory records being created; (2) total records with missing results; (3) average serum potassium results; and (4) total duplicated tests on a patient. The goal was to detect HIT system failures causing: data loss at the record level; data loss at the field level; erroneous data; and unintended duplication of data. Time-series models of the indices were constructed, and statistical process control charts were used to detect unexpected behaviors. The ability of the models to detect HIT system failures was evaluated using simulated failures, each lasting for 24 h, with error rates ranging from 1% to 35%. Results In detecting data loss at the record level, the model achieved a sensitivity of 0.26 when the simulated error rate was 1%, while maintaining a specificity of 0.98. Detection performance improved with increasing error rates, achieving a perfect sensitivity when the error rate was 35%. In the detection of missing results, erroneous serum potassium results and unintended repetition of tests, perfect sensitivity was attained when the error rate was as small as 5%. Decreasing the error rate to 1% resulted in a drop in sensitivity to 0.65–0.85. Conclusions Syndromic surveillance methods can potentially be applied to monitor HIT systems, to facilitate the early detection of failures. PMID:23184193

  6. Hydrogen sulfide measurement using sulfide dibimane: critical evaluation with electrospray ion trap mass spectrometry

    PubMed Central

    Shen, Xinggui; Chakraborty, Sourav; Dugas, Tammy R; Kevil, Christopher G

    2015-01-01

    Accurate measurement of hydrogen sulfide bioavailability remains a technical challenge due to numerous issues involving sample processing, detection methods used, and actual biochemical products measured. Our group and others have reported that reverse phase HPLC detection of sulfide dibimane (SDB) product from the reaction of H2S/HS− with monobromobimane allows for analytical detection of hydrogen sulfide bioavailability in free and other biochemical forms. However, it remains unclear whether possible interfering contaminants may contribute to HPLC SDB peak readings that may result in inaccurate measurements of bioavailable sulfide. In this study, we critically compared hydrogen sulfide dependent SDB detection using reverse phase HPLC (RP-HPLC) versus quantitative SRM electrospray ionization mass spectrometry (ESI/MS) to obtain greater clarity into the validity of the reverse phase HPLC method for analytical measurement of hydrogen sulfide. Using an LCQ-deca ion-trap mass spectrometer, SDB was identified by ESI/MS positive ion mode, and quantified by selected reaction monitoring (SRM) using hydrocortisone as an internal standard. Collision induced dissociation (CID) parameters were optimized at MS2 level for SDB and hydrocortisone. ESI/MS detection of SDB standard was found to be a log order more sensitive than RP-HPLC with a lower limit of 0.25 nM. Direct comparison of tissue and plasma SDB levels using RP-HPLC and ESI/MS methods revealed comparable sulfide levels in plasma, aorta, heart, lung and brain. Together, these data confirm the use of SDB as valid indicator of H2S bioavailability and highlights differences between analytical detection methods. PMID:24932544

  7. An objective method for measuring face detection thresholds using the sweep steady-state visual evoked response

    PubMed Central

    Ales, Justin M.; Farzin, Faraz; Rossion, Bruno; Norcia, Anthony M.

    2012-01-01

    We introduce a sensitive method for measuring face detection thresholds rapidly, objectively, and independently of low-level visual cues. The method is based on the swept parameter steady-state visual evoked potential (ssVEP), in which a stimulus is presented at a specific temporal frequency while parametrically varying (“sweeping”) the detectability of the stimulus. Here, the visibility of a face image was increased by progressive derandomization of the phase spectra of the image in a series of equally spaced steps. Alternations between face and fully randomized images at a constant rate (3/s) elicit a robust first harmonic response at 3 Hz specific to the structure of the face. High-density EEG was recorded from 10 human adult participants, who were asked to respond with a button-press as soon as they detected a face. The majority of participants produced an evoked response at the first harmonic (3 Hz) that emerged abruptly between 30% and 35% phase-coherence of the face, which was most prominent on right occipito-temporal sites. Thresholds for face detection were estimated reliably in single participants from 15 trials, or on each of the 15 individual face trials. The ssVEP-derived thresholds correlated with the concurrently measured perceptual face detection thresholds. This first application of the sweep VEP approach to high-level vision provides a sensitive and objective method that could be used to measure and compare visual perception thresholds for various object shapes and levels of categorization in different human populations, including infants and individuals with developmental delay. PMID:23024355

  8. Methods for detection of GMOs in food and feed.

    PubMed

    Marmiroli, Nelson; Maestri, Elena; Gullì, Mariolina; Malcevschi, Alessio; Peano, Clelia; Bordoni, Roberta; De Bellis, Gianluca

    2008-10-01

    This paper reviews aspects relevant to detection and quantification of genetically modified (GM) material within the feed/food chain. The GM crop regulatory framework at the international level is evaluated with reference to traceability and labelling. Current analytical methods for the detection, identification, and quantification of transgenic DNA in food and feed are reviewed. These methods include quantitative real-time PCR, multiplex PCR, and multiplex real-time PCR. Particular attention is paid to methods able to identify multiple GM events in a single reaction and to the development of microdevices and microsensors, though they have not been fully validated for application.

  9. Current Challenges in Detecting Food Allergens by Shotgun and Targeted Proteomic Approaches: A Case Study on Traces of Peanut Allergens in Baked Cookies

    PubMed Central

    Pedreschi, Romina; Nørgaard, Jørgen; Maquet, Alain

    2012-01-01

    There is a need for selective and sensitive methods to detect the presence of food allergens at trace levels in highly processed food products. In this work, a combination of non-targeted and targeted proteomics approaches are used to illustrate the difficulties encountered in the detection of the major peanut allergens Ara h 1, Ara h 2 and Ara h 3 from a representative processed food matrix. Shotgun proteomics was employed for selection of the proteotypic peptides for targeted approaches via selective reaction monitoring. Peanut presence through detection of the proteotypic Ara h 3/4 peptides AHVQVVDSNGNR (m/z 432.5, 3+) and SPDIYNPQAGSLK (m/z 695.4, 2+) was confirmed and the developed method was able to detect peanut presence at trace levels (≥10 μg peanut g−1 matrix) in baked cookies. PMID:22413066

  10. A Chemoenzymatic Histology Method for O-GlcNAc Detection.

    PubMed

    Aguilar, Aime Lopez; Hou, Xiaomeng; Wen, Liuqing; Wang, Peng G; Wu, Peng

    2017-12-14

    Modification of nuclear and cytoplasmic proteins by the addition or removal of O-GlcNAc dynamically impacts multiple biological processes. Here, we present the development of a chemoenzymatic histology method for the detection of O-GlcNAc in tissue specimens. We applied this method to screen murine organs, uncovering specific O-GlcNAc distribution patterns in different tissue structures. We then utilized our histology method for O-GlcNAc detection in human brain specimens from healthy donors and donors with Alzheimer's disease and found higher levels of O-GlcNAc in specimens from healthy donors. We also performed an analysis using a multiple cancer tissue array, uncovering different O-GlcNAc levels between healthy and cancerous tissues, as well as different O-GlcNAc cellular distributions within certain tissue specimens. This chemoenzymatic histology method therefore holds great potential for revealing the biology of O-GlcNAc in physiopathological processes. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. A competitive chemiluminescence enzyme immunoassay method for β-defensin-2 detection in transgenic mice.

    PubMed

    Yang, Xi; Zhou, Tao; Yu, Lei; Tan, Wenwen; Zhou, Rui; Hu, Yonggang

    2015-03-01

    A competitive chemiluminescence enzyme immunoassay (CLEIA) method for porcine β-defensin-2 (pBD-2) detection in transgenic mice was established. Several factors that affect detection, including luminol, p-iodophenol and hydrogen peroxide concentrations, as well as pH, were studied and optimized. The linear range of the proposed method for pBD-2 detection under optimal conditions was 0.05-80 ng/mL with a correlation coefficient of 0.9960. Eleven detections of a 30 ng/mL pBD-2 standard sample were performed. Reproducible results were obtained with a relative standard deviation of 3.94%. The limit of detection of the method for pBD-2 was 3.5 pg/mL (3σ). The proposed method was applied to determine pBD-2 expression levels in the tissues of pBD-2 transgenic mice, and compared with LC-MS/MS and quantitative real-time reverse-transcriptase polymerase chain reaction. This suggests that the CLEIA can be used as a valuable method to detect and quantify pBD-2. Copyright © 2014 John Wiley & Sons, Ltd.

  12. SIMULTANEOUS CONCENTRATION AND REAL-TIME DETECTION OF MULTIPLE CLASSES OF MICROBIAL PATHOGENS FROM DRINKING WATER

    EPA Science Inventory

    Key CCL viruses will be rapidly detected at low levels in water samples concentrated by a rapid HFUF or a new thin-sheet (TSM) electropositive filter adsorption-elution method and compared with the approved EPA method (1MDS VIRADEL). A unified and rapid virus concentration, n...

  13. Shiga toxin-producing Escherichia coli in meat: a preliminary simulation study on detection capabilities for three sampling methods

    USDA-ARS?s Scientific Manuscript database

    The objective of this simulation study is to determine which sampling method (Cozzini core sampler, core drill shaving, and N-60 surface excision) will better detect Shiga Toxin-producing Escherichia coli (STEC) at varying levels of contamination when present in the meat. 1000 simulated experiments...

  14. VIDAS Listeria species Xpress (LSX).

    PubMed

    Johnson, Ronald; Mills, John

    2013-01-01

    The AOAC GovVal study compared the VIDAS Listeria species Xpress (LSX) to the Health Products and Food Branch MFHPB-30 reference method for detection of Listeria on stainless steel. The LSX method utilizes a novel and proprietary enrichment media, Listeria Xpress broth, enabling detection of Listeria species in environmental samples with the automated VIDAS in a minimum of 26 h. The LSX method also includes the use of the chromogenic media, chromID Ottaviani Agosti Agar (OAA) and chromID Lmono for confirmation of LSX presumptive results. In previous AOAC validation studies comparing VIDAS LSX to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference methods, the LSX method was approved as AOAC Official Method 2010.02 for the detection of Listeria species in dairy products, vegetables, seafood, raw meats and poultry, and processed meats and poultry, and as AOAC Performance Tested Method 100501 in a variety of foods and on environmental surfaces. The GovVal comparative study included 20 replicate test portions each at two contamination levels for stainless steel where fractionally positive results (5-15 positive results/20 replicate portions tested) were obtained by at least one method at one level. Five uncontaminated controls were included. In the stainless steel artificially contaminated surface study, there were 25 confirmed positives by the VIDAS LSX assay and 22 confirmed positives by the standard culture methods. Chi-square analysis indicated no statistical differences between the VIDAS LSX method and the MFHPB-30 standard methods at the 5% level of significance. Confirmation of presumptive LSX results with the chromogenic OAA and Lmono media was shown to be equivalent to the appropriate reference method agars. The data in this study demonstrate that the VIDAS LSX method is an acceptable alternative method to the MFHPB-30 standard culture method for the detection of Listeria species on stainless steel.

  15. Speciation of chromium using reversed phase-high performance liquid chromatography coupled to different spectrometric detection methods

    NASA Astrophysics Data System (ADS)

    Andrle, C. M.; Jakubowski, N.; Broekaert, J. A. C.

    1997-02-01

    Speciation of Cr(III) and Cr(VI) based on the formation of different complexes with ammonium-pyrrolidinedithioate (APDC) in a continuous flow technique and their preconcentration using solid phase extraction (SPE) have been elaborated and applied to the analysis of waste waters from the galvanic industry. The Cr complexes were separated and determined using reversed phase-high performance liquid chromatography (RP-HPLC) coupled to different detection methods, namely UV-detection, graphite furnace-atomic absorption spectrometry (GF-AAS) and inductively coupled plasma mass spectrometry with hydraulic high pressure nebulization (HHPN/ICP-MS). After optimization the detection limits for Cr(III) and Cr(VI) of all methods are at the μg 1 -1 level and the precision in terms of RSD is 5% ( cCr = 100 μg 1 -1, N = 10). The procedure was applied to the determination of Cr(III) and Cr(VI) at the μg 1 -1 level in galvanic waste waters, and its accuracy was approved by comparing the results with those of independent methods.

  16. Detection and Classification of Motor Vehicle Noise in a Forested Landscape

    NASA Astrophysics Data System (ADS)

    Brown, Casey L.; Reed, Sarah E.; Dietz, Matthew S.; Fristrup, Kurt M.

    2013-11-01

    Noise emanating from human activity has become a common addition to natural soundscapes and has the potential to harm wildlife and erode human enjoyment of nature. In particular, motor vehicles traveling along roads and trails produce high levels of both chronic and intermittent noise, eliciting varied responses from a wide range of animal species. Anthropogenic noise is especially conspicuous in natural areas where ambient background sound levels are low. In this article, we present an acoustic method to detect and analyze motor vehicle noise. Our approach uses inexpensive consumer products to record sound, sound analysis software to automatically detect sound events within continuous recordings and measure their acoustic properties, and statistical classification methods to categorize sound events. We describe an application of this approach to detect motor vehicle noise on paved, gravel, and natural-surface roads, and off-road vehicle trails in 36 sites distributed throughout a national forest in the Sierra Nevada, CA, USA. These low-cost, unobtrusive methods can be used by scientists and managers to detect anthropogenic noise events for many potential applications, including ecological research, transportation and recreation planning, and natural resource management.

  17. Quantification of plasma myo-inositol using gas chromatography-mass spectrometry.

    PubMed

    Guo, Jin; Shi, Yingfei; Xu, Chengbao; Zhong, Rugang; Zhang, Feng; Zhang, Ting; Niu, Bo; Wang, Jianhua

    2016-09-01

    Myo-inositol (MI) deficiency is associated with an increased risk for neural tube defects (NTDs), mental disorders and metabolic diseases. We developed a gas chromatography-mass spectrometry (GC-MS) method to detect MI in human plasma, which was accurate, relatively efficient and convenient for clinical application. An external standard method was used for determination of plasma MI. Samples were analyzed by GC-MS after derivatization. The stable-isotope labeled internal standard approach was used to validate the method's accuracy. Alpha fetal protein (AFP) was detected by chemiluminescence immunoassay. The method was validated by determining the linearity, sensitivity and recovery rate. There was a good agreement between the internal standard approach and the present method. The NTD-affected pregnancies showed lower plasma MI (P=0.024) and higher AFP levels (P=0.001) than control. Maternal MI level showed a better discrimination in spina bifida subgroup, while AFP level showed a better discrimination in anencephaly subgroup after stratification analysis. We developed a sensitive and reliable method for the detection of clinical plasma MI, which might be a marker for NTDs screening, and established fundamental knowledge for clinical diagnosis and prevention for the diseases related to disturbed MI metabolism. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Deconvolution single shot multibox detector for supermarket commodity detection and classification

    NASA Astrophysics Data System (ADS)

    Li, Dejian; Li, Jian; Nie, Binling; Sun, Shouqian

    2017-07-01

    This paper proposes an image detection model to detect and classify supermarkets shelves' commodity. Based on the principle of the features directly affects the accuracy of the final classification, feature maps are performed to combine high level features with bottom level features. Then set some fixed anchors on those feature maps, finally the label and the position of commodity is generated by doing a box regression and classification. In this work, we proposed a model named Deconvolutiuon Single Shot MultiBox Detector, we evaluated the model using 300 images photographed from real supermarket shelves. Followed the same protocol in other recent methods, the results showed that our model outperformed other baseline methods.

  19. Detecting persons concealed in a vehicle

    DOEpatents

    Tucker, Jr., Raymond W.

    2005-03-29

    An improved method for detecting the presence of humans or animals concealed within in a vehicle uses a combination of the continuous wavelet transform and a ratio-based energy calculation to determine whether the motion detected using seismic sensors placed on the vehicle is due to the presence of a heartbeat within the vehicle or is the result of motion caused by external factors such as the wind. The method performs well in the presence of light to moderate ambient wind levels, producing far fewer false alarm indications. The new method significantly improves the range of ambient environmental conditions under which human presence detection systems can reliably operate.

  20. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor

    PubMed Central

    Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung

    2018-01-01

    Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies. PMID:29695113

  1. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor.

    PubMed

    Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung

    2018-04-24

    Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies.

  2. Coronary arteries segmentation based on the 3D discrete wavelet transform and 3D neutrosophic transform.

    PubMed

    Chen, Shuo-Tsung; Wang, Tzung-Dau; Lee, Wen-Jeng; Huang, Tsai-Wei; Hung, Pei-Kai; Wei, Cheng-Yu; Chen, Chung-Ming; Kung, Woon-Man

    2015-01-01

    Most applications in the field of medical image processing require precise estimation. To improve the accuracy of segmentation, this study aimed to propose a novel segmentation method for coronary arteries to allow for the automatic and accurate detection of coronary pathologies. The proposed segmentation method included 2 parts. First, 3D region growing was applied to give the initial segmentation of coronary arteries. Next, the location of vessel information, HHH subband coefficients of the 3D DWT, was detected by the proposed vessel-texture discrimination algorithm. Based on the initial segmentation, 3D DWT integrated with the 3D neutrosophic transformation could accurately detect the coronary arteries. Each subbranch of the segmented coronary arteries was segmented correctly by the proposed method. The obtained results are compared with those ground truth values obtained from the commercial software from GE Healthcare and the level-set method proposed by Yang et al., 2007. Results indicate that the proposed method is better in terms of efficiency analyzed. Based on the initial segmentation of coronary arteries obtained from 3D region growing, one-level 3D DWT and 3D neutrosophic transformation can be applied to detect coronary pathologies accurately.

  3. Systematic assessment of the performance of whole-genome amplification for SNP/CNV detection and β-thalassemia genotyping.

    PubMed

    He, Fei; Zhou, Wanjun; Cai, Ren; Yan, Tizhen; Xu, Xiangmin

    2018-04-01

    In this study, we aimed to assess the performance of two whole-genome amplification methods, multiple displacement amplification (MDA), and multiple annealing and looping-based amplification cycle (MALBAC), for β-thalassemia genotyping and single-nucleotide polymorphism (SNP)/copy-number variant (CNV) detection using two DNA sequencing assays. We collected peripheral blood, cell lines, and discarded embryos, and carried out MALBAC and MDA on single-cell and five-cell samples. We detected and statistically analyzed differences in the amplification efficiency, positive predictive value, sensitivity, allele dropout (ADO) rate, SNPs, and CV values between the two methods. Through Sanger sequencing at the single-cell and five-cell levels, we showed that both the amplification rate and ADO rate of MDA were better than those using MALBAC, and the sensitivity and positive predictive value obtained from MDA were higher than those from MALBAC for β-thalassemia genotyping. Using next-generation sequencing (NGS) at the single-cell level, we confirmed that MDA has better properties than MALBAC for SNP detection. However, MALBAC was more stable and homogeneous than MDA using low-depth NGS at the single-cell level for CNV detection. We conclude that MALBAC is the better option for CNV detection, while MDA is better suited for SNV detection.

  4. Finding Direction in the Search for Selection.

    PubMed

    Thiltgen, Grant; Dos Reis, Mario; Goldstein, Richard A

    2017-01-01

    Tests for positive selection have mostly been developed to look for diversifying selection where change away from the current amino acid is often favorable. However, in many cases we are interested in directional selection where there is a shift toward specific amino acids, resulting in increased fitness in the species. Recently, a few methods have been developed to detect and characterize directional selection on a molecular level. Using the results of evolutionary simulations as well as HIV drug resistance data as models of directional selection, we compare two such methods with each other, as well as against a standard method for detecting diversifying selection. We find that the method to detect diversifying selection also detects directional selection under certain conditions. One method developed for detecting directional selection is powerful and accurate for a wide range of conditions, while the other can generate an excessive number of false positives.

  5. Automatic detection method for mura defects on display film surface using modified Weber's law

    NASA Astrophysics Data System (ADS)

    Kim, Myung-Muk; Lee, Seung-Ho

    2014-07-01

    We propose a method that automatically detects mura defects on display film surfaces using a modified version of Weber's law. The proposed method detects mura defects regardless of their properties and shapes by identifying regions perceived by human vision as mura using the brightness of pixel and image distribution ratio of mura in an image histogram. The proposed detection method comprises five stages. In the first stage, the display film surface image is acquired and a gray-level shift performed. In the second and third stages, the image histogram is acquired and analyzed, respectively. In the fourth stage, the mura range is acquired. This is followed by postprocessing in the fifth stage. Evaluations of the proposed method conducted using 200 display film mura image samples indicate a maximum detection rate of ˜95.5%. Further, the results of application of the Semu index for luminance mura in flat panel display (FPD) image quality inspection indicate that the proposed method is more reliable than a popular conventional method.

  6. Image processing based detection of lung cancer on CT scan images

    NASA Astrophysics Data System (ADS)

    Abdillah, Bariqi; Bustamam, Alhadi; Sarwinda, Devvi

    2017-10-01

    In this paper, we implement and analyze the image processing method for detection of lung cancer. Image processing techniques are widely used in several medical problems for picture enhancement in the detection phase to support the early medical treatment. In this research we proposed a detection method of lung cancer based on image segmentation. Image segmentation is one of intermediate level in image processing. Marker control watershed and region growing approach are used to segment of CT scan image. Detection phases are followed by image enhancement using Gabor filter, image segmentation, and features extraction. From the experimental results, we found the effectiveness of our approach. The results show that the best approach for main features detection is watershed with masking method which has high accuracy and robust.

  7. Determination of BPA, BPB, BPF, BADGE and BFDGE in canned energy drinks by molecularly imprinted polymer cleaning up and UPLC with fluorescence detection.

    PubMed

    Gallo, Pasquale; Di Marco Pisciottano, Ilaria; Esposito, Francesco; Fasano, Evelina; Scognamiglio, Gelsomina; Mita, Gustavo Damiano; Cirillo, Teresa

    2017-04-01

    A new method for simultaneous determination of five bisphenols in canned energy drinks by UPLC with fluorescence detection, after clean up on molecularly imprinted polymers, is herein described. The method was validated at two concentration levels, calculating trueness, repeatability and within-laboratory reproducibility, specificity, linearity of detector response, the limits of quantifications and the limits of detection for each bisphenol. The method is specific, reliable and very sensitive, allowing for determination of bisphenol F diglycidyl ether (BFDGE), bisphenol A (BPA), bisphenol B (BPB), bisphenol F (BPF) and bisphenol A diglycidyl ether (BADGE) down to 0.50ng/mL; it was employed to determine contamination levels from these bisphenols in forty energy drinks of different brands, collected from the market in Naples. BPA was detected in 17 out of 40 samples (42.5%); in some energy drinks also BPF, BADGE and BFDGE were determined. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Parallel computation of level set method for 500 Hz visual servo control

    NASA Astrophysics Data System (ADS)

    Fei, Xianfeng; Igarashi, Yasunobu; Hashimoto, Koichi

    2008-11-01

    We propose a 2D microorganism tracking system using a parallel level set method and a column parallel vision system (CPV). This system keeps a single microorganism in the middle of the visual field under a microscope by visual servoing an automated stage. We propose a new energy function for the level set method. This function constrains an amount of light intensity inside the detected object contour to control the number of the detected objects. This algorithm is implemented in CPV system and computational time for each frame is 2 [ms], approximately. A tracking experiment for about 25 s is demonstrated. Also we demonstrate a single paramecium can be kept tracking even if other paramecia appear in the visual field and contact with the tracked paramecium.

  9. Multiscale-Driven approach to detecting change in Synthetic Aperture Radar (SAR) imagery

    NASA Astrophysics Data System (ADS)

    Gens, R.; Hogenson, K.; Ajadi, O. A.; Meyer, F. J.; Myers, A.; Logan, T. A.; Arnoult, K., Jr.

    2017-12-01

    Detecting changes between Synthetic Aperture Radar (SAR) images can be a useful but challenging exercise. SAR with its all-weather capabilities can be an important resource in identifying and estimating the expanse of events such as flooding, river ice breakup, earthquake damage, oil spills, and forest growth, as it can overcome shortcomings of optical methods related to cloud cover. However, detecting change in SAR imagery can be impeded by many factors including speckle, complex scattering responses, low temporal sampling, and difficulty delineating boundaries. In this presentation we use a change detection method based on a multiscale-driven approach. By using information at different resolution levels, we attempt to obtain more accurate change detection maps in both heterogeneous and homogeneous regions. Integrated within the processing flow are processes that 1) improve classification performance by combining Expectation-Maximization algorithms with mathematical morphology, 2) achieve high accuracy in preserving boundaries using measurement level fusion techniques, and 3) combine modern non-local filtering and 2D-discrete stationary wavelet transform to provide robustness against noise. This multiscale-driven approach to change detection has recently been incorporated into the Alaska Satellite Facility (ASF) Hybrid Pluggable Processing Pipeline (HyP3) using radiometrically terrain corrected SAR images. Examples primarily from natural hazards are presented to illustrate the capabilities and limitations of the change detection method.

  10. Ultrasonic technique for detection of liquids in copper tubing process lines

    NASA Astrophysics Data System (ADS)

    Dudley, W. A.

    1980-10-01

    An ultrasonic pulse-echo method developed for semiquantitative measurement of liquid levels in copper tubing is described. This ultrasonic approach is of particular value when used as a pre-maintenance diagnostic tool in repairing process lines containing hazardous liquids. Performance tests show that water and similar liquids can be directly detected to fill levels as low as 1/16 in. For water fills below 1/16 in., direct level detection is impractical because of signal resolution limitations. However, this fill condition is indirectly measurable and is detected by the effect of observed degradation of the adjacent wall echo pattern. Fill conditions for liquids associated with high sound attenuation such as oil can be indirectly determined.

  11. Multilevel depth and image fusion for human activity detection.

    PubMed

    Ni, Bingbing; Pei, Yong; Moulin, Pierre; Yan, Shuicheng

    2013-10-01

    Recognizing complex human activities usually requires the detection and modeling of individual visual features and the interactions between them. Current methods only rely on the visual features extracted from 2-D images, and therefore often lead to unreliable salient visual feature detection and inaccurate modeling of the interaction context between individual features. In this paper, we show that these problems can be addressed by combining data from a conventional camera and a depth sensor (e.g., Microsoft Kinect). We propose a novel complex activity recognition and localization framework that effectively fuses information from both grayscale and depth image channels at multiple levels of the video processing pipeline. In the individual visual feature detection level, depth-based filters are applied to the detected human/object rectangles to remove false detections. In the next level of interaction modeling, 3-D spatial and temporal contexts among human subjects or objects are extracted by integrating information from both grayscale and depth images. Depth information is also utilized to distinguish different types of indoor scenes. Finally, a latent structural model is developed to integrate the information from multiple levels of video processing for an activity detection. Extensive experiments on two activity recognition benchmarks (one with depth information) and a challenging grayscale + depth human activity database that contains complex interactions between human-human, human-object, and human-surroundings demonstrate the effectiveness of the proposed multilevel grayscale + depth fusion scheme. Higher recognition and localization accuracies are obtained relative to the previous methods.

  12. Usefulness of the Poincaré maps in detection of T-wave alternans in precordial leads of standard ECG--a comparison with the spectral method.

    PubMed

    Ruta, J; Strumiłło, P

    2001-01-01

    T-wave alternans (TWA) at microvolt level is considered as an important non-invasive risk factor for sudden death. Several methods are used to measure such repolarization variations, but each of them has some limitations. The purpose of our study is to assess the usefulness of Poincaré maps, a method based on nonlinear dynamics theory, in detection of repolarization abnormalities. In 30 postinfarction patients presence of TWA in precordial ECG leads was assessed by the spectral method (SM) and by the Poincaré maps (PM). Quantitative measures of both methods: alternans voltage (AV) and alternans distance (AD) were compared using linear regression. Significant correlation between both measures (r = 0.92, p < 0.01) was found. The value of AD > or = 10 microV was accepted as significant for the presence of T-wave alternans. Poincaré mapping seems to be a useful and simple method for detection of TWA. The alternans distance equal or greater than 10 microV can be considered as a level determinative for the presence of TWA.

  13. Validating a High Performance Liquid Chromatography-Ion Chromatography (HPLC-IC) Method with Conductivity Detection After Chemical Suppression for Water Fluoride Estimation.

    PubMed

    Bondu, Joseph Dian; Selvakumar, R; Fleming, Jude Joseph

    2018-01-01

    A variety of methods, including the Ion Selective Electrode (ISE), have been used for estimation of fluoride levels in drinking water. But as these methods suffer many drawbacks, the newer method of IC has replaced many of these methods. The study aimed at (1) validating IC for estimation of fluoride levels in drinking water and (2) to assess drinking water fluoride levels of villages in and around Vellore district using IC. Forty nine paired drinking water samples were measured using ISE and IC method (Metrohm). Water samples from 165 randomly selected villages in and around Vellore district were collected for fluoride estimation over 1 year. Standardization of IC method showed good within run precision, linearity and coefficient of variance with correlation coefficient R 2  = 0.998. The limit of detection was 0.027 ppm and limit of quantification was 0.083 ppm. Among 165 villages, 46.1% of the villages recorded water fluoride levels >1.00 ppm from which 19.4% had levels ranging from 1 to 1.5 ppm, 10.9% had recorded levels 1.5-2 ppm and about 12.7% had levels of 2.0-3.0 ppm. Three percent of villages had more than 3.0 ppm fluoride in the water tested. Most (44.42%) of these villages belonged to Jolarpet taluk with moderate to high (0.86-3.56 ppm) water fluoride levels. Ion Chromatography method has been validated and is therefore a reliable method in assessment of fluoride levels in the drinking water. While the residents of Jolarpet taluk (Vellore distict) are found to be at a high risk of developing dental and skeletal fluorosis.

  14. The method for glomerulations detection in histological images of prostate

    NASA Astrophysics Data System (ADS)

    Zavarzin, A. A.; Pronichev, A. N.; Rodionova, O. V.; Komochkina, E. A.; Prilepskaya, E. A.; Kovylina, M. V.

    2018-01-01

    In the work presented, a method for detecting glomeruli in pictures of histological preparations of the prostate gland is described, the presence of which indicates a malignant neoplasm. Pathological structures at the level of microimages are investigated. The developed method is the result of joint activity of the National Research Nuclear University "MEPhI" and the Moscow State Medical and Stomatological University named after A.I. Evdokimova.

  15. Rapid and sensitive detection of hepatitis A virus in representative food matrices.

    PubMed

    Papafragkou, Efstathia; Plante, Michelle; Mattison, Kirsten; Bidawid, Sabah; Karthikeyan, Kalavethi; Farber, Jeffrey M; Jaykus, Lee-Ann

    2008-01-01

    Hepatitis A virus (HAV) is an important cause of foodborne disease worldwide. The detection of this virus in naturally contaminated food products is complicated by the absence of a reliable culture method, low levels of contamination, and the presence of matrix-associated compounds which inhibit molecular detection. In this study, we report a novel method to concentrate HAV from foods prior to the application of reverse transcription-PCR (RT-PCR) for detection. Specifically, we used cationically charged magnetic particles with an automated capture system (Pathatrix) to concentrate the virus from 25 g samples of artificially contaminated lettuce, strawberries, green onions, deli-turkey, oysters, and cake with frosting. Detection limits varied according to the product but in most cases, the virus could be consistently detected at input levels corresponding to 10(2)PFU/25 g food sample. For some products, detection was possible at levels as low as 10(-1)PFU/25 g. The assay was applied by a second independent laboratory and was also used to confirm viral contamination of produce items associated with a recent HAV outbreak. Parallel infectivity assays demonstrated that the cationically charged particles bound approximately 50% of the input virus. This is the first application of the automated magnetic capture technology to the concentration of viruses from foods, and it offers promise for facilitating the rapid detection of HAV from naturally contaminated products.

  16. Occurrence of pharmaceuticals and personal care products in effluent-dominated Saudi Arabian coastal waters of the Red Sea.

    PubMed

    Ali, Aasim M; Rønning, Helene Thorsen; Alarif, Walied; Kallenborn, Roland; Al-Lihaibi, Sultan S

    2017-05-01

    The occurrence of selected pharmaceuticals and personal care products (PPCPs) and the pesticide atrazine were investigated in seawater samples collected from stations located at effluent dominated sites in the Saudi Arabian coastal waters of the Red Sea. PPCPs were analysed using solid phase extraction (SPE) followed by high performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS). A multi component method for the ultra-trace level quantification of 13 target PPCPs in Seawater was developed and validated for the here performed study. The method procedure is described in detail in the supplementary material section. 26 samples from 7 distinct locations (2 directly influenced by continuous sewage release) were chosen for the sampling of surface seawater. Based upon local sales information, 25 target substances (20 PPCPs, 4 pesticides and 1 stimulant) were chosen for the here reported method development. Thirteen PPCPs were detected and quantified in a total of 26 seawater samples. Metformin, diclofenac, acetaminophen, and caffeine were identified as the most abundant PPCPs, detected in maximum concentration higher than 3 μg/L (upper quantification limit for the here developed method). Concentrations were in the range of 7- >3000 (metformin), 3000 ng/L (caffeine). The contribution of direct sewage release on the PPCP levels detected was obvious, the target PPCPs were detected in the Al-Arbaeen and Al-Shabab coastal lagoons in high concentrations due to the low water exchange with the open sea and still ongoing sewage releases in the lagoons. Also, substantial amounts of antibiotics were detected in all samples. Levels and distribution profile of the detected PPCPs revealed high level release rates and give raise to concern on potential environmental risks associated with the here document long term exposure on the fragile coastal marine environment of the region but particularly in the nearby protected coral reef environment outside the harbour region of Jeddah. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Noninvasive method for determining the liquid level and density inside of a container

    DOEpatents

    Sinha, Dipen N.

    2000-01-01

    Noninvasive method for determining the liquid level and density inside of a container having arbitrary dimension and shape. By generating a flexural acoustic wave in the container shell and measuring the phase difference of the detected flexural wave from that of the originally generated wave a small distance from the generated wave, while moving the generation and detection means through the liquid/vapor interface, this interface can be detected. Both the wave generation and wave detection may be achieved by transducers on the surface of the container. A change in the phase difference over the outer surface of the vessel signifies that a liquid/vapor interface has been crossed, while the magnitude of the phase difference can be related to fluid density immediately opposite the measurement position on the surface of the vessel.

  18. Detection of free liquid in containers of solidified radioactive waste

    DOEpatents

    Greenhalgh, Wilbur O.

    1985-01-01

    A method of nondestructively detecting the presence of free liquid within a sealed enclosure containing solidified waste by measuring the levels of waste at two diametrically opposite locations while slowly tilting the enclosure toward one of said locations. When the measured level remains constant at the other location, the measured level at said one location is noted and any measured difference of levels indicates the presence of liquid on the surface of the solidified waste. The absence of liquid in the enclosure is verified when the measured levels at both locations are equal.

  19. DNA Extraction Method Affects the Detection of a Fungal Pathogen in Formalin-Fixed Specimens Using qPCR.

    PubMed

    Adams, Andrea J; LaBonte, John P; Ball, Morgan L; Richards-Hrdlicka, Kathryn L; Toothman, Mary H; Briggs, Cheryl J

    2015-01-01

    Museum collections provide indispensable repositories for obtaining information about the historical presence of disease in wildlife populations. The pathogenic amphibian chytrid fungus Batrachochytrium dendrobatidis (Bd) has played a significant role in global amphibian declines, and examining preserved specimens for Bd can improve our understanding of its emergence and spread. Quantitative PCR (qPCR) enables Bd detection with minimal disturbance to amphibian skin and is significantly more sensitive to detecting Bd than histology; therefore, developing effective qPCR methodologies for detecting Bd DNA in formalin-fixed specimens can provide an efficient and effective approach to examining historical Bd emergence and prevalence. Techniques for detecting Bd in museum specimens have not been evaluated for their effectiveness in control specimens that mimic the conditions of animals most likely to be encountered in museums, including those with low pathogen loads. We used American bullfrogs (Lithobates catesbeianus) of known infection status to evaluate the success of qPCR to detect Bd in formalin-fixed specimens after three years of ethanol storage. Our objectives were to compare the most commonly used DNA extraction method for Bd (PrepMan, PM) to Macherey-Nagel DNA FFPE (MN), test optimizations for Bd detection with PM, and provide recommendations for maximizing Bd detection. We found that successful detection is relatively high (80-90%) when Bd loads before formalin fixation are high, regardless of the extraction method used; however, at lower infection levels, detection probabilities were significantly reduced. The MN DNA extraction method increased Bd detection by as much as 50% at moderate infection levels. Our results indicate that, for animals characterized by lower pathogen loads (i.e., those most commonly encountered in museum collections), current methods may underestimate the proportion of Bd-infected amphibians. Those extracting DNA from archived museum specimens should ensure that the techniques they are using are known to provide high-quality throughput DNA for later analysis.

  20. Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer.

    PubMed

    Chang, Yanli; Xu, Jianjun; Zhang, Qingyun

    2017-10-01

    Survivin is a tumor marker for bladder cancer; however the role of urinary survivin levels has not been fully elucidated due to the limitations of current detection methods. Based on two survivin-specific monoclonal antibodies (McAbs) already confirmed through enzyme linked immunosorbent assays, the present study aimed to establish a microplate magnetic chemiluminescence immunoassay (CLIA) for the detection of urinary survivin levels and evaluate its application for the diagnosis of patients with bladder cancer. Horseradish peroxidase and biotin conjugates were used to label two different anti-survivin McAbs, respectively. The labeled antibodies combined with survivin to form a sandwiched immune complex. The streptavidin magnetic particles (MPs) served as the solid phase and the separator. The relevant parameters involved in the immunoassay, including the immunoassay reagents used and the physicochemical parameters were optimized. Then, urine samples from 130 patients with bladder cancer and 113 healthy controls were detected, and analyzed using the established method. The method was linear to 1,000 ng/ml survivin with a detection limit of 0.83 ng/ml. The intra- and inter-assay coefficients of variation were <8, and <11%, respectively. The concentration of diluted survivin and the dilution ratios gave a linear correlation of 0.9989. The results demonstrated that the urinary survivin levels in patients with bladder cancer were significantly higher (P<0.001) compared with that in healthy controls. At a survivin concentration of 2.0884 ng/ml, the sensitivity and specificity were 86.9 and 61.9%, respectively. Furthermore, the urinary survivin levels were positively correlated with metastatic stage, histological stage and recurrence (P<0.01). In conclusion, the present study preliminarily proposed a microplate magnetic CLIA for survivin detection and further evaluated the value of urinary survivin as a diagnostic marker for bladder cancer.

  1. Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer

    PubMed Central

    Chang, Yanli; Xu, Jianjun; Zhang, Qingyun

    2017-01-01

    Survivin is a tumor marker for bladder cancer; however the role of urinary survivin levels has not been fully elucidated due to the limitations of current detection methods. Based on two survivin-specific monoclonal antibodies (McAbs) already confirmed through enzyme linked immunosorbent assays, the present study aimed to establish a microplate magnetic chemiluminescence immunoassay (CLIA) for the detection of urinary survivin levels and evaluate its application for the diagnosis of patients with bladder cancer. Horseradish peroxidase and biotin conjugates were used to label two different anti-survivin McAbs, respectively. The labeled antibodies combined with survivin to form a sandwiched immune complex. The streptavidin magnetic particles (MPs) served as the solid phase and the separator. The relevant parameters involved in the immunoassay, including the immunoassay reagents used and the physicochemical parameters were optimized. Then, urine samples from 130 patients with bladder cancer and 113 healthy controls were detected, and analyzed using the established method. The method was linear to 1,000 ng/ml survivin with a detection limit of 0.83 ng/ml. The intra- and inter-assay coefficients of variation were <8, and <11%, respectively. The concentration of diluted survivin and the dilution ratios gave a linear correlation of 0.9989. The results demonstrated that the urinary survivin levels in patients with bladder cancer were significantly higher (P<0.001) compared with that in healthy controls. At a survivin concentration of 2.0884 ng/ml, the sensitivity and specificity were 86.9 and 61.9%, respectively. Furthermore, the urinary survivin levels were positively correlated with metastatic stage, histological stage and recurrence (P<0.01). In conclusion, the present study preliminarily proposed a microplate magnetic CLIA for survivin detection and further evaluated the value of urinary survivin as a diagnostic marker for bladder cancer. PMID:28943911

  2. GMDD: a database of GMO detection methods

    PubMed Central

    Dong, Wei; Yang, Litao; Shen, Kailin; Kim, Banghyun; Kleter, Gijs A; Marvin, Hans JP; Guo, Rong; Liang, Wanqi; Zhang, Dabing

    2008-01-01

    Background Since more than one hundred events of genetically modified organisms (GMOs) have been developed and approved for commercialization in global area, the GMO analysis methods are essential for the enforcement of GMO labelling regulations. Protein and nucleic acid-based detection techniques have been developed and utilized for GMOs identification and quantification. However, the information for harmonization and standardization of GMO analysis methods at global level is needed. Results GMO Detection method Database (GMDD) has collected almost all the previous developed and reported GMOs detection methods, which have been grouped by different strategies (screen-, gene-, construct-, and event-specific), and also provide a user-friendly search service of the detection methods by GMO event name, exogenous gene, or protein information, etc. In this database, users can obtain the sequences of exogenous integration, which will facilitate PCR primers and probes design. Also the information on endogenous genes, certified reference materials, reference molecules, and the validation status of developed methods is included in this database. Furthermore, registered users can also submit new detection methods and sequences to this database, and the newly submitted information will be released soon after being checked. Conclusion GMDD contains comprehensive information of GMO detection methods. The database will make the GMOs analysis much easier. PMID:18522755

  3. 3D change detection at street level using mobile laser scanning point clouds and terrestrial images

    NASA Astrophysics Data System (ADS)

    Qin, Rongjun; Gruen, Armin

    2014-04-01

    Automatic change detection and geo-database updating in the urban environment are difficult tasks. There has been much research on detecting changes with satellite and aerial images, but studies have rarely been performed at the street level, which is complex in its 3D geometry. Contemporary geo-databases include 3D street-level objects, which demand frequent data updating. Terrestrial images provides rich texture information for change detection, but the change detection with terrestrial images from different epochs sometimes faces problems with illumination changes, perspective distortions and unreliable 3D geometry caused by the lack of performance of automatic image matchers, while mobile laser scanning (MLS) data acquired from different epochs provides accurate 3D geometry for change detection, but is very expensive for periodical acquisition. This paper proposes a new method for change detection at street level by using combination of MLS point clouds and terrestrial images: the accurate but expensive MLS data acquired from an early epoch serves as the reference, and terrestrial images or photogrammetric images captured from an image-based mobile mapping system (MMS) at a later epoch are used to detect the geometrical changes between different epochs. The method will automatically mark the possible changes in each view, which provides a cost-efficient method for frequent data updating. The methodology is divided into several steps. In the first step, the point clouds are recorded by the MLS system and processed, with data cleaned and classified by semi-automatic means. In the second step, terrestrial images or mobile mapping images at a later epoch are taken and registered to the point cloud, and then point clouds are projected on each image by a weighted window based z-buffering method for view dependent 2D triangulation. In the next step, stereo pairs of the terrestrial images are rectified and re-projected between each other to check the geometrical consistency between point clouds and stereo images. Finally, an over-segmentation based graph cut optimization is carried out, taking into account the color, depth and class information to compute the changed area in the image space. The proposed method is invariant to light changes, robust to small co-registration errors between images and point clouds, and can be applied straightforwardly to 3D polyhedral models. This method can be used for 3D street data updating, city infrastructure management and damage monitoring in complex urban scenes.

  4. Pine Beetle Detection

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Earth Systems Science Office scientists worked with officials in St. Tammany Parish, La., to detect and battle pine beetle infestation in Fontainebleu State Park. The scientists used a new method of detecting plant stress by using special lenses and modified sensors to detect a change in light levels given off by the plant before the stress is visible to the naked eye.

  5. Characterization of inter-tissue and inter-strain variability of TCE glutathione conjugation metabolites DCVG, DCVC, and NAcDCVC in the mouse.

    PubMed

    Luo, Yu-Syuan; Furuya, Shinji; Chiu, Weihsueh; Rusyn, Ivan

    2018-01-01

    Trichloroethylene (TCE) is a ubiquitous environmental toxicant that is a liver and kidney carcinogen. Conjugation of TCE with glutathione (GSH) leads to formation of nepthrotoxic and mutagenic metabolites postulated to be critical for kidney cancerdevelopment; however, relatively little is known regarding their tissue levels as previous analytical methods for their detection lacked sensitivity. Here, an LC-MS/MS-based method for simultaneous detection of S-(1,2-dichlorovinyl)-glutathione (DCVG), S-(1,2-dichlorovinyl)-L-cysteine (DCVC), and N-acetyl-S-(1,2-dichlorovinyl)-L-cysteine (NAcDCVC) in multiple mouse tissues was developed. This analytical method is rapid, sensitive (limits of detection (LOD) 3-30 fmol across metabolites and tissues), and robust to quantify all three metabolites in liver, kidneys, and serum. The method was used to characterize inter-tissue and inter-strain variability in formation of conjugative metabolites of TCE. Single oral dose of TCE (24, 240 or 800 mg/kg) was administered to male mice from 20 inbred strains of Collaborative Cross. Inter-strain variability in the levels of DCVG, DCVC, and NAcDCVC (GSD = 1.6-2.9) was observed. Whereas NAcDCVC was distributed equally among analyzed tissues, highest levels of DCVG were detected in liver and DCVC in kidneys. Evidence indicated that inter-strain variability in conjugative metabolite formation of TCE might affect susceptibility to adverse health effects and that this method might aid in filling data gaps in human health assessment of TCE.

  6. Comparative study of fourteen alkaloids from Uncaria rhynchophylla hooks and leaves using HPLC-diode array detection-atmospheric pressure chemical ionization/MS method.

    PubMed

    Qu, Jialin; Gong, Tianxing; Ma, Bin; Zhang, Lin; Kano, Yoshihiro; Yuan, Dan

    2012-01-01

    The purpose of the study is to compare alkaloid profile of Uncaria rhynchophylla hooks and leaves. Ten oxindole alkaloids and four glycosidic indole alkaloids were identified using HPLC-diode array detection (DAD) or LC-atmospheric pressure chemical ionization (APCI)-MS method, and a HPLC-UV method for simultaneous quantification of major alkaloids was validated. The hooks are characterized by high levels of four oxindole alkaloids rhynchophylline (R), isorhynchophylline (IR), corynoxeine (C) and isocorynoxeine (IC), while the leaves contained high level of two glycosidic indole alkaloids vincoside lactam (VL) and strictosidine (S). The presented methods have proven its usefulness in chemical characterization of U. rhynchophylla hooks and leaves.

  7. Colorimetric detection of cholesterol based on enzyme modified gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Nirala, Narsingh R.; Saxena, Preeti S.; Srivastava, Anchal

    2018-02-01

    We develop a simple colorimetric method for determination of free cholesterol in aqueous solution based on functionalized gold nanoparticles with cholesterol oxidase. Functionalized gold nanoparticles interact with free cholesterol to produce H2O2 in proportion to the level of cholesterol visually is being detected. The quenching in optical properties and agglomeration of functionalized gold nanoparticles play a key role in cholesterol sensing due to the electron accepting property of H2O2. While the lower ranges of cholesterol (lower detection limit i.e. 0.2 mg/dL) can be effectively detected using fluorescence study, the absorption study attests evident visual color change which becomes effective for detection of higher ranges of cholesterol (lower detection limit i.e. 19 mg/dL). The shades of red gradually change to blue/purple as the level of cholesterol detected (as evident at 100 mg/dL) using unaided eye without the use of expensive instruments. The potential of the proposed method to be applied in the field is shown by the proposed cholesterol measuring color wheel.

  8. Scene text detection via extremal region based double threshold convolutional network classification

    PubMed Central

    Zhu, Wei; Lou, Jing; Chen, Longtao; Xia, Qingyuan

    2017-01-01

    In this paper, we present a robust text detection approach in natural images which is based on region proposal mechanism. A powerful low-level detector named saliency enhanced-MSER extended from the widely-used MSER is proposed by incorporating saliency detection methods, which ensures a high recall rate. Given a natural image, character candidates are extracted from three channels in a perception-based illumination invariant color space by saliency-enhanced MSER algorithm. A discriminative convolutional neural network (CNN) is jointly trained with multi-level information including pixel-level and character-level information as character candidate classifier. Each image patch is classified as strong text, weak text and non-text by double threshold filtering instead of conventional one-step classification, leveraging confident scores obtained via CNN. To further prune non-text regions, we develop a recursive neighborhood search algorithm to track credible texts from weak text set. Finally, characters are grouped into text lines using heuristic features such as spatial location, size, color, and stroke width. We compare our approach with several state-of-the-art methods, and experiments show that our method achieves competitive performance on public datasets ICDAR 2011 and ICDAR 2013. PMID:28820891

  9. Evaluation of a hygiene monitor for detection of contamination in dental surgeries.

    PubMed

    Douglas, C W; Rothwell, P S

    1991-05-11

    Routines for disinfecting working surfaces in dental surgeries are difficult to monitor without time-consuming and labour-intensive microbiological techniques, yet effective monitoring is a vital part of cross-infection control. Easy to use, on-site methods would be valuable in this context. This study evaluates a portable monitor, the Biotrace Hygiene Monitor, which uses bioluminescence to measure adenosine triphosphate (ATP) on surfaces. Under laboratory conditions, the ability of the monitor to detect whole saliva and Streptococcus sanguis was determined and, in the general practice environment, the level of ATP on surfaces in five dental surgeries was assessed. The minimum amount of saliva detectable was 0.5 microliters and in surgeries, the monitor readily identified numerous surfaces with fairly high levels of ATP. Routine cleaning methods sometimes left ATP on surfaces at levels which represented a cross-infection risk, if it is assumed that the ATP derived from patients' saliva. Modification of cleaning methods resulted in a reduction of ATP levels to within that which could be considered reasonably practicably safe. It is concluded that the Biotrace Hygiene Monitor offers a simple and valuable means of monitoring dental practice cleaning routines.

  10. Method for detecting moment connection fracture using high-frequency transients in recorded accelerations

    USGS Publications Warehouse

    Rodgers, J.E.; Elebi, M.

    2011-01-01

    The 1994 Northridge earthquake caused brittle fractures in steel moment frame building connections, despite causing little visible building damage in most cases. Future strong earthquakes are likely to cause similar damage to the many un-retrofitted pre-Northridge buildings in the western US and elsewhere. Without obvious permanent building deformation, costly intrusive inspections are currently the only way to determine if major fracture damage that compromises building safety has occurred. Building instrumentation has the potential to provide engineers and owners with timely information on fracture occurrence. Structural dynamics theory predicts and scale model experiments have demonstrated that sudden, large changes in structure properties caused by moment connection fractures will cause transient dynamic response. A method is proposed for detecting the building-wide level of connection fracture damage, based on observing high-frequency, fracture-induced transient dynamic responses in strong motion accelerograms. High-frequency transients are short (<1 s), sudden-onset waveforms with frequency content above 25 Hz that are visually apparent in recorded accelerations. Strong motion data and damage information from intrusive inspections collected from 24 sparsely instrumented buildings following the 1994 Northridge earthquake are used to evaluate the proposed method. The method's overall success rate for this data set is 67%, but this rate varies significantly with damage level. The method performs reasonably well in detecting significant fracture damage and in identifying cases with no damage, but fails in cases with few fractures. Combining the method with other damage indicators and removing records with excessive noise improves the ability to detect the level of damage. ?? 2010 Elsevier B.V. All rights reserved.

  11. Automatic Polyp Detection via A Novel Unified Bottom-up and Top-down Saliency Approach.

    PubMed

    Yuan, Yixuan; Li, Dengwang; Meng, Max Q-H

    2017-07-31

    In this paper, we propose a novel automatic computer-aided method to detect polyps for colonoscopy videos. To find the perceptually and semantically meaningful salient polyp regions, we first segment images into multilevel superpixels. Each level corresponds to different sizes of superpixels. Rather than adopting hand-designed features to describe these superpixels in images, we employ sparse autoencoder (SAE) to learn discriminative features in an unsupervised way. Then a novel unified bottom-up and top-down saliency method is proposed to detect polyps. In the first stage, we propose a weak bottom-up (WBU) saliency map by fusing the contrast based saliency and object-center based saliency together. The contrast based saliency map highlights image parts that show different appearances compared with surrounding areas while the object-center based saliency map emphasizes the center of the salient object. In the second stage, a strong classifier with Multiple Kernel Boosting (MKB) is learned to calculate the strong top-down (STD) saliency map based on samples directly from the obtained multi-level WBU saliency maps. We finally integrate these two stage saliency maps from all levels together to highlight polyps. Experiment results achieve 0.818 recall for saliency calculation, validating the effectiveness of our method. Extensive experiments on public polyp datasets demonstrate that the proposed saliency algorithm performs favorably against state-of-the-art saliency methods to detect polyps.

  12. Detection of ultra-low levels of DNA changes by drinking water: epidemiologically important finding.

    PubMed

    Kumari, Parmila; Kamiseki, Meiko; Biyani, Manish; Suzuki, Miho; Nemoto, Naoto; Aita, Takuyo; Nishigaki, Koichi

    2015-02-01

    The safety of drinking water is essential to our health. In this context, the mutagenicity of water needs to be checked strictly. However, from the methodological limit, the lower concentration (less than parts per million) of mutagenicity could not be detected, though there have been of interest in the effect of less concentration mutagens. Here, we describe a highly sensitive mutation assay that detects mutagens at the ppb level, termed genome profiling-based mutation assay (GPMA). This consists of two steps; (i) Escherichia coli culture in the medium with/without mutagens and (ii) Genome profiling (GP) method (an integrated method of random PCR, temperature gradient gel electrophoresis and computer-aided normalization). Owing to high sensitivity of this method, very low concentration of mutagens in tap water could be directly detected without introducing burdensome concentration processes, enabling rapid measurement of low concentration samples. Less expectedly, all of the tap waters tested (22 samples) were shown to be significantly mutagenic while mineral waters were not. Resultantly, this article informs two facts that the GPMA method is competent to measure the mutagenicity of waters directly and the experimental results supported the former reports that the city tap waters contain very low level of mutagenicity reagent trihalomethanes. © The Authors 2014. Published by Oxford University Press on behalf of the Japanese Biochemical Society. All rights reserved.

  13. Polarimetric Analysis of the Long Duration Gamma-Ray Burst GRB 160530A With the Balloon Borne Compton Spectrometer and Imager

    NASA Astrophysics Data System (ADS)

    Lowell, A. W.; Boggs, S. E.; Chiu, C. L.; Kierans, C. A.; Sleator, C.; Tomsick, J. A.; Zoglauer, A. C.; Chang, H.-K.; Tseng, C.-H.; Yang, C.-Y.; Jean, P.; von Ballmoos, P.; Lin, C.-H.; Amman, M.

    2017-10-01

    A long duration gamma-ray burst, GRB 160530A, was detected by the Compton Spectrometer and Imager (COSI) during the 2016 COSI Super Pressure Balloon campaign. As a Compton telescope, COSI is inherently sensitive to the polarization of gamma-ray sources in the energy range 0.2-5.0 MeV. We measured the polarization of GRB 160530A using (1) a standard method (SM) based on fitting the distribution of azimuthal scattering angles with a modulation curve and (2) an unbinned, maximum likelihood method (MLM). In both cases, the measured polarization level was below the 99% confidence minimum detectable polarization levels of 72.3% ± 0.8% (SM) and 57.5% ± 0.8% (MLM). Therefore, COSI did not detect polarized gamma-ray emission from this burst. Our most constraining 90% confidence upper limit on the polarization level was 46% (MLM).

  14. Pesticides in near-surface aquifers: An assessment using highly sensitive analytical methods and tritium

    USGS Publications Warehouse

    Kolpin, D.W.; Goolsby, D.A.; Thurman, E.M.

    1995-01-01

    In 1992, the U.S. Geological Survey (USGS) determined the distribution of pesticides in near-surface aquifers of the midwestern USA to be much more widespread than originally determined during a 1991 USGS study. The frequency of pesticide detection increased from 28.4% during the 1991 study to 59.0% during the 1992 study. This increase in pesticide detection was primarily the result of a more sensitive analytical method that used reporting limits as much as 20 times lower than previously available and a threefold increase in the number of pesticide metabolites analyzed. No pesticide concentrations exceeded the U.S. Environmental Protection Agency's (USEPAs) maximum contaminant levels or health advisory levels for drinking water. However, five of the six most frequently detected compounds during 1992 were pesticide metabolites that currently do not have drinking water standards determined. The frequent presence of pesticide metabolites for this study documents the importance of obtaining information on these compounds to understand the fate and transport of pesticides in the hydrologic system. It appears that the 56 parent compounds analyzed follow similar pathways through the hydrologic system as atrazine. When atrazine was detected by routine or sensitive analytical methods, there was an increased likelihood of detecting additional parent compounds. As expected, the frequency of pesticide detection was highly dependent on the analytical reporting limit. The number of atrazine detections more than doubled as the reporting limit decreased from 0.10 to 0.01 µg/L. The 1992 data provided no indication that the frequency of pesticide detection would level off as improved analytical methods provide concentrations below 0.003 µg/L. A relation was determined between groundwater age and the frequency of pesticide detection, with 15.8% of the samples composed of pre-1953 water and 70.3% of the samples of post-1953 water having a detection of at least one pesticide or metabolite. Pre-1953 water is less likely to contain pesticides because it tends to predate the use of pesticides to increase crop production in the Midwest. Pre-1953 water was more likely to occur in the near-surface bedrock aquifers (50.0%) than in the near-surface unconsolidated aquifers (9.1%) sampled.

  15. Multiscale infrared and visible image fusion using gradient domain guided image filtering

    NASA Astrophysics Data System (ADS)

    Zhu, Jin; Jin, Weiqi; Li, Li; Han, Zhenghao; Wang, Xia

    2018-03-01

    For better surveillance with infrared and visible imaging, a novel hybrid multiscale decomposition fusion method using gradient domain guided image filtering (HMSD-GDGF) is proposed in this study. In this method, hybrid multiscale decomposition with guided image filtering and gradient domain guided image filtering of source images are first applied before the weight maps of each scale are obtained using a saliency detection technology and filtering means with three different fusion rules at different scales. The three types of fusion rules are for small-scale detail level, large-scale detail level, and base level. Finally, the target becomes more salient and can be more easily detected in the fusion result, with the detail information of the scene being fully displayed. After analyzing the experimental comparisons with state-of-the-art fusion methods, the HMSD-GDGF method has obvious advantages in fidelity of salient information (including structural similarity, brightness, and contrast), preservation of edge features, and human visual perception. Therefore, visual effects can be improved by using the proposed HMSD-GDGF method.

  16. Love-Wave Sensors Combined with Microfluidics for Fast Detection of Biological Warfare Agents

    PubMed Central

    Matatagui, Daniel; Fontecha, José Luis; Fernández, María Jesús; Gràcia, Isabel; Cané, Carles; Santos, José Pedro; Horrillo, María Carmen

    2014-01-01

    The following paper examines a time-efficient method for detecting biological warfare agents (BWAs). The method is based on a system of a Love-wave immunosensor combined with a microfluidic chip which detects BWA samples in a dynamic mode. In this way a continuous flow-through of the sample is created, promoting the reaction between antigen and antibody and allowing a fast detection of the BWAs. In order to prove this method, static and dynamic modes have been simulated and different concentrations of BWA simulants have been tested with two immunoreactions: phage M13 has been detected using the mouse monoclonal antibody anti-M13 (AM13), and the rabbit immunoglobulin (Rabbit IgG) has been detected using the polyclonal antibody goat anti-rabbit (GAR). Finally, different concentrations of each BWA simulants have been detected with a fast response time and a desirable level of discrimination among them has been achieved. PMID:25029282

  17. Mercury bioaccumulation in organisms from three Puerto Rican estuaries.

    PubMed

    Burger, J; Cooper, K; Saliva, J; Gochfeld, D; Lipsky, D; Gochfeld, M

    1992-09-01

    We analyzed mercury levels in shrimp (Palaemonetes sp.), Blue Crabs (Callinectes sp.), fish (Tarpon Megalops atlantica and Tilapia Tilapia mossambica), lizards (Ameiva exsul), Cattle Egret (Bubulcus ibis) and Moorhen (Gallinula chloropus) in three estuaries in Puerto Rico in 1988. There were no quantifiable concentrations greater than the method detection limit of mercury in shrimp, crabs and lizards from any site. Mercury levels were also below detection limits in Tilapia, except for specimens collected at Frontera Creek, allegedly contaminated with mercury. However, mercury levels ranged from 92-238 μg/kg (wet weight) in Tarpon, a predaceous fish that feeds on smaller fish. Few of the birds had detectable levels of mercury. Our results indicate relatively low concentrations of mercury in biota collected in all of the three estuaries at most trophic levels, although 10 of 12 Tarpon fillet samples from Frontera had detectable mercury compared to 3 of 12 fillet samples for the other two lagoons.

  18. Comparison of a bioassay and a liquid chromatography-fluorescence-mass spectrometry(n) method for the detection of incurred enrofloxacin residues in chicken tissues.

    PubMed

    Schneider, M J; Donoghue, D J

    2004-05-01

    Regulatory monitoring for most antibiotic residues in edible poultry tissues is often accomplished with accurate, although expensive and technically demanding, chemical analytical techniques. The purpose of this study is to determine if a simple, inexpensive bioassay could detect fluoroquinolone (FQ) residues in chicken muscle above the FDA established tolerance (300 ppb) comparable to a liquid chromatography-fluorescencemass spectrometry(n) method. To produce incurred enrofloxacin (ENRO) tissues (where ENRO is incorporated into complex tissue matrices) for the method comparison, 40-d-old broilers (mixed sex) were orally dosed through drinking water for 3 d at the FDA-approved dose of ENRO (50 ppm). At the end of each day of the 3-d dosing period and for 3 d postdosing, birds were sacrificed and breast and thigh muscle collected and analyzed. Both methods were able to detect ENRO at and below the tolerance level in the muscle, with limits of detection of 26 ppb (bioassay), 0.1 ppb for ENRO, and 0.5 ppb for the ENRO metabolite, ciprofloxacin (liquid chromatography-fluorescence-mass spectrometry(n)). All samples that had violative levels of antibiotic were detected by the bioassay. These results support the use of this bioassay as a screening method for examining large numbers of samples for regulatory monitoring. Positive samples should then be examined by a more extensive method, such as liquid chromatography-fluorescence-mass spectrometry(n), to provide confirmation of the analyte.

  19. Brain MRI Tumor Detection using Active Contour Model and Local Image Fitting Energy

    NASA Astrophysics Data System (ADS)

    Nabizadeh, Nooshin; John, Nigel

    2014-03-01

    Automatic abnormality detection in Magnetic Resonance Imaging (MRI) is an important issue in many diagnostic and therapeutic applications. Here an automatic brain tumor detection method is introduced that uses T1-weighted images and K. Zhang et. al.'s active contour model driven by local image fitting (LIF) energy. Local image fitting energy obtains the local image information, which enables the algorithm to segment images with intensity inhomogeneities. Advantage of this method is that the LIF energy functional has less computational complexity than the local binary fitting (LBF) energy functional; moreover, it maintains the sub-pixel accuracy and boundary regularization properties. In Zhang's algorithm, a new level set method based on Gaussian filtering is used to implement the variational formulation, which is not only vigorous to prevent the energy functional from being trapped into local minimum, but also effective in keeping the level set function regular. Experiments show that the proposed method achieves high accuracy brain tumor segmentation results.

  20. Development of HPLC-ELSD method for determination of maltodextrin in raw milk.

    PubMed

    Moraes, Flávia Santana; da Costa, Marion Pereira; de Melo Silva, Vitor Luiz; de Barros Pinto Moreira, Rodrigo Vilela; de Barros, Raphael Ferreira; Mársico, Eliane Teixeira; Conte-Junior, Carlos Adam; de Oliveira Silva, Adriana Cristina

    2017-02-15

    An analytical method was developed and validated for the determination of maltodextrin in raw milk, using high-performance liquid chromatography with evaporative light scattering detection. Maltodextrin content was evaluated in adulterated raw milk using a Supelcosil LC-NH2 (25cm×4.6mm) column and isocratic elution (68% of acetonitrile). Validation parameters exhibited adequate linearity, with relative standard deviation values between 0.74 and 2.16% (n=10) for repeatability and 0.11-19.39% (n=5) for intermediate precision. Limits of detection and quantification were 0.78 and 1.56mg.mL(-1), respectively, and recovery rates were between 91 and 93% for three levels. The application of this method shows that maltodextrin concentrations found in adulterated samples are lower than expected, which may be related to the quality of the commercial maltodextrin used. The method proposed proved to be simple and appropriate for the determination of maltodextrin in raw milk, with detection down to adulteration levels of 1%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. GraphPrints: Towards a Graph Analytic Method for Network Anomaly Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harshaw, Chris R; Bridges, Robert A; Iannacone, Michael D

    This paper introduces a novel graph-analytic approach for detecting anomalies in network flow data called \\textit{GraphPrints}. Building on foundational network-mining techniques, our method represents time slices of traffic as a graph, then counts graphlets\\textemdash small induced subgraphs that describe local topology. By performing outlier detection on the sequence of graphlet counts, anomalous intervals of traffic are identified, and furthermore, individual IPs experiencing abnormal behavior are singled-out. Initial testing of GraphPrints is performed on real network data with an implanted anomaly. Evaluation shows false positive rates bounded by 2.84\\% at the time-interval level, and 0.05\\% at the IP-level with 100\\% truemore » positive rates at both.« less

  2. Trace analysis of multi-class pesticide residues in Chinese medicinal health wines using gas chromatography with electron capture detection

    PubMed Central

    Kong, Wei-Jun; Liu, Qiu-Tao; Kong, Dan-Dan; Liu, Qian-Zhen; Ma, Xin-Ping; Yang, Mei-Hua

    2016-01-01

    A method is described for multi-residue, high-throughput determination of trace levels of 22 organochlorine pesticides (OCPs) and 5 pyrethroid pesticides (PYPs) in Chinese medicinal (CM) health wines using a QuEChERS (quick, easy, cheap, effective, rugged, and safe) based extraction method and gas chromatography-electron capture detection (GC-ECD). Several parameters were optimized to improve preparation and separation time while still maintaining high sensitivity. Validation tests of spiked samples showed good linearities for 27 pesticides (R = 0.9909–0.9996) over wide concentration ranges. Limits of detection (LODs) and quantification (LOQs) were measured at ng/L levels, 0.06–2 ng/L and 0.2–6 ng/L for OCPs and 0.02–3 ng/L and 0.06–7 ng/L for PYPs, respectively. Inter- and intra-day precision tests showed variations of 0.65–9.89% for OCPs and 0.98–13.99% for PYPs, respectively. Average recoveries were in the range of 47.74–120.31%, with relative standard deviations below 20%. The developed method was then applied to analyze 80 CM wine samples. Beta-BHC (Benzene hexachloride) was the most frequently detected pesticide at concentration levels of 5.67–31.55 mg/L, followed by delta-BHC, trans-chlordane, gamma-BHC, and alpha-BHC. The validated method is simple and economical, with adequate sensitivity for trace levels of multi-class pesticides. It could be adopted by laboratories for this and other types of complex matrices analysis. PMID:26883080

  3. Trace analysis of multi-class pesticide residues in Chinese medicinal health wines using gas chromatography with electron capture detection

    NASA Astrophysics Data System (ADS)

    Kong, Wei-Jun; Liu, Qiu-Tao; Kong, Dan-Dan; Liu, Qian-Zhen; Ma, Xin-Ping; Yang, Mei-Hua

    2016-02-01

    A method is described for multi-residue, high-throughput determination of trace levels of 22 organochlorine pesticides (OCPs) and 5 pyrethroid pesticides (PYPs) in Chinese medicinal (CM) health wines using a QuEChERS (quick, easy, cheap, effective, rugged, and safe) based extraction method and gas chromatography-electron capture detection (GC-ECD). Several parameters were optimized to improve preparation and separation time while still maintaining high sensitivity. Validation tests of spiked samples showed good linearities for 27 pesticides (R = 0.9909-0.9996) over wide concentration ranges. Limits of detection (LODs) and quantification (LOQs) were measured at ng/L levels, 0.06-2 ng/L and 0.2-6 ng/L for OCPs and 0.02-3 ng/L and 0.06-7 ng/L for PYPs, respectively. Inter- and intra-day precision tests showed variations of 0.65-9.89% for OCPs and 0.98-13.99% for PYPs, respectively. Average recoveries were in the range of 47.74-120.31%, with relative standard deviations below 20%. The developed method was then applied to analyze 80 CM wine samples. Beta-BHC (Benzene hexachloride) was the most frequently detected pesticide at concentration levels of 5.67-31.55 mg/L, followed by delta-BHC, trans-chlordane, gamma-BHC, and alpha-BHC. The validated method is simple and economical, with adequate sensitivity for trace levels of multi-class pesticides. It could be adopted by laboratories for this and other types of complex matrices analysis.

  4. Growth of Staphylococcus aureus and Fungi in Beef Snacks at Various Levels of Water Activity

    DTIC Science & Technology

    1988-01-01

    concentration, the detection methods used were sensitive to 0.1 yg/mL. The assay method used in the present study detects 0.1 to 1 ng/mL of...DoD 5200.1-R, Information Security Program Regulation, Chapter IX For Unclassified/Limited Distribution Documents: Destroy by any method that...CONTENTS PREFACE iii LIST OF FI8ÜRES v LIST OF TABLES . v INTRODUCTION 1 MATERIALS AND METHODS 1 Bee-f snack production 1 Experimental samples 1

  5. Detection of ingested nitromethane and reliable creatinine assessment using multiple common analytical methods.

    PubMed

    Murphy, Christine M; Devlin, John J; Beuhler, Michael C; Cheifetz, Paul; Maynard, Susan; Schwartz, Michael D; Kacinko, Sherri

    2018-04-01

    Nitromethane, found in fuels used for short distance racing, model cars, and model airplanes, produces a falsely elevated serum creatinine with standard creatinine analysis via the Jaffé method. Erroneous creatinine elevation often triggers extensive testing, leads to inaccurate diagnoses, and delayed or inappropriate medical interventions. Multiple reports in the literature identify "enzymatic assays" as an alternative method to detect the true value of creatinine, but this ambiguity does not help providers translate what type of enzymatic assay testing can be done in real time to determine if there is indeed false elevation. We report seven cases of ingested nitromethane where creatinine was determined via Beckman Coulter ® analyser using the Jaffé method, Vitros ® analyser, or i-Stat ® point-of-care testing. Nitromethane was detected and semi-quantified using a common clinical toxic alcohol analysis method, and quantified by headspace-gas chromatography-mass spectrometry. When creatinine was determined using i-Stat ® point-of-care testing or a Vitros ® analyser, levels were within the normal range. Comparatively, all initial creatinine levels obtained via the Jaffé method were elevated. Nitromethane concentrations ranged from 42 to 310 μg/mL. These cases demonstrate reliable assessment of creatinine through other enzymatic methods using a Vitros ® analyser or i-STAT ® . Additionally, nitromethane is detectable and quantifiable using routine alcohols gas chromatography analysis and by headspace-gas chromatography-mass spectrometry.

  6. DuPont Qualicon BAX System polymerase chain reaction assay. Performance Tested Method 100201.

    PubMed

    Tice, George; Andaloro, Bridget; Fallon, Dawn; Wallace, F Morgan

    2009-01-01

    A recent outbreak of Salmonella in peanut butter has highlighted the need for validation of rapid detection methods. A multilaboratory study for detecting Salmonella in peanut butter was conducted as part of the AOAC Research Institute Emergency Response Validation program for methods that detect outbreak threats to food safety. Three sites tested spiked samples from the same master mix according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) method and the BAX System method. Salmonella Typhimurium (ATCC 14028) was grown in brain heart infusion for 24 h at 37 degrees C, then diluted to appropriate levels for sample inoculation. Master samples of peanut butter were spiked at high and low target levels, mixed, and allowed to equilibrate at room temperature for 2 weeks. Spike levels were low [1.08 most probable number (MPN)/25 g]; high (11.5 MPN/25 g) and unspiked to serve as negative controls. Each master sample was divided into 25 g portions and coded to blind the samples. Twenty portions of each spiked master sample and five portions of the unspiked sample were tested at each site. At each testing site, samples were blended in 25 g portions with 225 mL prewarmed lactose broth until thoroughly homogenized, then allowed to remain at room temperature for 55-65 min. Samples were adjusted to a pH of 6.8 +/- 0.2, if necessary, and incubated for 22-26 h at 35 degrees C. Across the three reporting laboratories, the BAX System detected Salmonella in 10/60 low-spike samples and 58/60 high-spike samples. The reference FDA-BAM method yielded positive results for 11/60 low-spike and 58/60 high-spike samples. Neither method demonstrated positive results for any of the 15 unspiked samples.

  7. PEST reduces bias in forced choice psychophysics.

    PubMed

    Taylor, M M; Forbes, S M; Creelman, C D

    1983-11-01

    Observers performed several different detection tasks using both the PEST adaptive psychophysical procedure and a fixed-level (method of constant stimuli) psychophysical procedure. In two experiments, PEST runs targeted at P (C) = 0.80 were immediately followed by fixed-level detection runs presented at the difficulty level resulting from the PEST run. The fixed-level runs yielded P (C) about 0.75. During the fixed-level runs, the probability of a correct response was greater when the preceding response was correct than when it was wrong. Observers, even highly trained ones, perform in a nonstationary manner. The sequential dependency data can be used to determine a lower bound for the observer's "true" capability when performing optimally; this lower bound is close to the PEST target, and well above the forced choice P (C). The observer's "true" capability is the measure used by most theories of detection performance. A further experiment compared psychometric functions obtained from a set of PEST runs using different targets with those obtained from blocks of fixed-level trials at different levels. PEST results were more stable across observers, performance at all but the highest signal levels was better with PEST, and the PEST psychometric functions had shallower slopes. We hypothesize that PEST permits the observer to keep track of what he is trying to detect, whereas in the fixed-level method performance is disrupted by memory failure. Some recently suggested "more virulent" versions of PEST may be subject to biases similar to those of the fixed-level procedures.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Detecting Edges in Images by Use of Fuzzy Reasoning

    NASA Technical Reports Server (NTRS)

    Dominguez, Jesus A.; Klinko, Steve

    2003-01-01

    A method of processing digital image data to detect edges includes the use of fuzzy reasoning. The method is completely adaptive and does not require any advance knowledge of an image. During initial processing of image data at a low level of abstraction, the nature of the data is indeterminate. Fuzzy reasoning is used in the present method because it affords an ability to construct useful abstractions from approximate, incomplete, and otherwise imperfect sets of data. Humans are able to make some sense of even unfamiliar objects that have imperfect high-level representations. It appears that to perceive unfamiliar objects or to perceive familiar objects in imperfect images, humans apply heuristic algorithms to understand the images

  9. Level crossing analysis of cosmic microwave background radiation: a method for detecting cosmic strings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Movahed, M. Sadegh; Khosravi, Shahram, E-mail: m.s.movahed@ipm.ir, E-mail: khosravi@ipm.ir

    2011-03-01

    In this paper we study the footprint of cosmic string as the topological defects in the very early universe on the cosmic microwave background radiation. We develop the method of level crossing analysis in the context of the well-known Kaiser-Stebbins phenomenon for exploring the signature of cosmic strings. We simulate a Gaussian map by using the best fit parameter given by WMAP-7 and then superimpose cosmic strings effects on it as an incoherent and active fluctuations. In order to investigate the capability of our method to detect the cosmic strings for the various values of tension, Gμ, a simulated puremore » Gaussian map is compared with that of including cosmic strings. Based on the level crossing analysis, the superimposed cosmic string with Gμ∼>4 × 10{sup −9} in the simulated map without instrumental noise and the resolution R = 1' could be detected. In the presence of anticipated instrumental noise the lower bound increases just up to Gμ∼>5.8 × 10{sup −9}.« less

  10. A new HPLC method for the detection of iodine applied to natural samples of edible seaweeds and commercial seaweed food products.

    PubMed

    Nitschke, Udo; Stengel, Dagmar B

    2015-04-01

    Rich in micronutrients and considered to contain high iodine levels, seaweeds have multiple applications as food/supplements and nutraceuticals with potential health implications. Here, we describe the development and validation of a new analytical method to quantify iodine as iodide (I(-)) using an isocratic HPLC system with UV detection; algal iodine was converted to I(-) via dry alkaline incineration. The method was successfully applied to 19 macroalgal species from three taxonomic groups and five commercially available seaweed food products. Fesh kelps contained highest levels, reaching >1.0% per dry weight (DW), but concentrations differed amongst thallus parts. In addition to kelps, other brown (Fucales: ∼ 0.05% DW) and some red species (∼ 0.05% DW) can also serve as a rich source of iodine; lowest iodine concentrations were detected in green macroalgae (∼ 0.005% DW), implying that quantities recommended for seaweed consumption may require species-specific re-evaluation to reach adequate daily intake levels. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. An efficient cloud detection method for high resolution remote sensing panchromatic imagery

    NASA Astrophysics Data System (ADS)

    Li, Chaowei; Lin, Zaiping; Deng, Xinpu

    2018-04-01

    In order to increase the accuracy of cloud detection for remote sensing satellite imagery, we propose an efficient cloud detection method for remote sensing satellite panchromatic images. This method includes three main steps. First, an adaptive intensity threshold value combined with a median filter is adopted to extract the coarse cloud regions. Second, a guided filtering process is conducted to strengthen the textural features difference and then we conduct the detection process of texture via gray-level co-occurrence matrix based on the acquired texture detail image. Finally, the candidate cloud regions are extracted by the intersection of two coarse cloud regions above and we further adopt an adaptive morphological dilation to refine them for thin clouds in boundaries. The experimental results demonstrate the effectiveness of the proposed method.

  12. Dual Low-Rank Pursuit: Learning Salient Features for Saliency Detection.

    PubMed

    Lang, Congyan; Feng, Jiashi; Feng, Songhe; Wang, Jingdong; Yan, Shuicheng

    2016-06-01

    Saliency detection is an important procedure for machines to understand visual world as humans do. In this paper, we consider a specific saliency detection problem of predicting human eye fixations when they freely view natural images, and propose a novel dual low-rank pursuit (DLRP) method. DLRP learns saliency-aware feature transformations by utilizing available supervision information and constructs discriminative bases for effectively detecting human fixation points under the popular low-rank and sparsity-pursuit framework. Benefiting from the embedded high-level information in the supervised learning process, DLRP is able to predict fixations accurately without performing the expensive object segmentation as in the previous works. Comprehensive experiments clearly show the superiority of the proposed DLRP method over the established state-of-the-art methods. We also empirically demonstrate that DLRP provides stronger generalization performance across different data sets and inherits the advantages of both the bottom-up- and top-down-based saliency detection methods.

  13. A source-attractor approach to network detection of radiation sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Qishi; Barry, M. L..; Grieme, M.

    Radiation source detection using a network of detectors is an active field of research for homeland security and defense applications. We propose Source-attractor Radiation Detection (SRD) method to aggregate measurements from a network of detectors for radiation source detection. SRD method models a potential radiation source as a magnet -like attractor that pulls in pre-computed virtual points from the detector locations. A detection decision is made if a sufficient level of attraction, quantified by the increase in the clustering of the shifted virtual points, is observed. Compared with traditional methods, SRD has the following advantages: i) it does not requiremore » an accurate estimate of the source location from limited and noise-corrupted sensor readings, unlike the localizationbased methods, and ii) its virtual point shifting and clustering calculation involve simple arithmetic operations based on the number of detectors, avoiding the high computational complexity of grid-based likelihood estimation methods. We evaluate its detection performance using canonical datasets from Domestic Nuclear Detection Office s (DNDO) Intelligence Radiation Sensors Systems (IRSS) tests. SRD achieves both lower false alarm rate and false negative rate compared to three existing algorithms for network source detection.« less

  14. Hierarchical detection of red lesions in retinal images by multiscale correlation filtering

    NASA Astrophysics Data System (ADS)

    Zhang, Bob; Wu, Xiangqian; You, Jane; Li, Qin; Karray, Fakhri

    2009-02-01

    This paper presents an approach to the computer aided diagnosis (CAD) of diabetic retinopathy (DR) -- a common and severe complication of long-term diabetes which damages the retina and cause blindness. Since red lesions are regarded as the first signs of DR, there has been extensive research on effective detection and localization of these abnormalities in retinal images. In contrast to existing algorithms, a new approach based on Multiscale Correlation Filtering (MSCF) and dynamic thresholding is developed. This consists of two levels, Red Lesion Candidate Detection (coarse level) and True Red Lesion Detection (fine level). The approach was evaluated using data from Retinopathy On-line Challenge (ROC) competition website and we conclude our method to be effective and efficient.

  15. Methods of detecting and controlling mucoid Pseudomonas biofilm production

    NASA Technical Reports Server (NTRS)

    Qiu, Dongru (Inventor); Yu, Hongwei D. (Inventor)

    2013-01-01

    Compositions and methods for detecting and controlling the conversion to mucoidy in Pseudomonas aeruginosa are disclosed. The present invention provides for detecting the switch from nonmucoid to mucoid state of P. aeruginosa by measuring mucE expression or MucE protein levels. The interaction between MucE and AlgW controls the switch to mucoidy in wild type P. aeruginosa. Also disclosed is an alginate biosynthesis heterologous expression system for use in screening candidate substances that inhibit conversion to mucoidy.

  16. Methods of detecting and controlling mucoid pseudomonas biofilm production

    NASA Technical Reports Server (NTRS)

    Qiu, Dongru (Inventor); Yu, Hongwei D. (Inventor)

    2010-01-01

    Compositions and methods for detecting and controlling the conversion to mucoidy in Pseudomonas aeruginosa are disclosed. The present invention provides for detecting the switch from nonmucoid to mucoid state of P. aeruginosa by measuring mucE expression or MucE protein levels. The interaction between MucE and AlgW controls the switch to mucoidy in wild type P. aeruginosa. Also disclosed is an alginate biosynthesis heterologous expression system for use in screening candidate substances that inhibit conversion to mucoidy.

  17. Rapid pretreatment and detection of trace aflatoxin B1 in traditional soybean sauce.

    PubMed

    Xie, Fang; Lai, WeiHua; Saini, Jasdeep; Shan, Shan; Cui, Xi; Liu, DaoFeng

    2014-05-01

    Soybean sauce, a traditional fermented food in China, has different levels of aflatoxin B1 pollution. Two kinds of direct and indirect immunomagnetic bead methods for the pretreatment of aflatoxin B1 were evaluated in this work. A method was established to detect aflatoxin B1 in soybean sauce using an immunomagnetic bead system for pretreatment and ELISA for quantification. The pretreatment method of immunomagnetic beads performed better compared with the conventional extraction and immunoaffinity column method. ELISA exhibited a good linear relationship at an aflatoxin B1 concentration of 0.05-0.3μg/kg (r(2)=0.9842). The average recoveries across spike levels varied from 0.5 to 7μg/kg were 83.6-104% with a relative standard deviation between 4.2% and 11.7%. With the advantages of rapid detection, easy operation, simple equipment, sensitivity, accuracy, and high recovery; this method can be well applied in the trace determination of aflatoxin B1 in soybean sauce samples. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Multiresidue determination of ten nonsteroidal anti-inflammatory drugs in bovine, porcine, and chicken liver tissues by HPLC-MS/MS.

    PubMed

    Kang, JeongWoo; Park, Su-Jeong; Park, Hae-Chul; Gedi, Vinayakumar; So, ByungJae; Lee, Kwang-Jick

    2014-09-01

    Nonsteroidal anti-inflammatory drugs (NSAIDs) are the group of drugs having the therapeutic efficacy of analgesic and antipyretic. To detect health-threatening residues of NSAIDs, a fast and easy multiresidue method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) was described. Ten NSAIDs were extracted from the tissues using 2 mL of acetonitrile and 0.1 mL of 2 mM ammonium formate in distilled water. After clean-up using C18 sorbent, it was evaporated under nitrogen, reconstituted with 1 mL distilled water and analyzed by LC-MS/MS. The method was validated based on guideline for residue testing laboratory. Furthermore, the method has also been applied successfully to detect ten NSAIDs from bovine, porcine, and chicken liver tissues. In a total of 315 liver samples tested, acetylic salicylic acid was detected from 28 porcine and 2 chicken liver tissues at levels of 13 ∼ 576 and 50 ∼ 53 ng/g, respectively. Subsequently, paracetamol was detected in 15 porcine liver tissues with a detection levels of 28 ∼ 381 ng/g. Phenylbutazone and its metabolite, oxyphenylbutazone, were detected at 247 and 15 ng/g range in one of the bovine liver tissue, respectively.

  19. Detection of lobular structures in normal breast tissue.

    PubMed

    Apou, Grégory; Schaadt, Nadine S; Naegel, Benoît; Forestier, Germain; Schönmeyer, Ralf; Feuerhake, Friedrich; Wemmert, Cédric; Grote, Anne

    2016-07-01

    Ongoing research into inflammatory conditions raises an increasing need to evaluate immune cells in histological sections in biologically relevant regions of interest (ROIs). Herein, we compare different approaches to automatically detect lobular structures in human normal breast tissue in digitized whole slide images (WSIs). This automation is required to perform objective and consistent quantitative studies on large data sets. In normal breast tissue from nine healthy patients immunohistochemically stained for different markers, we evaluated and compared three different image analysis methods to automatically detect lobular structures in WSIs: (1) a bottom-up approach using the cell-based data for subsequent tissue level classification, (2) a top-down method starting with texture classification at tissue level analysis of cell densities in specific ROIs, and (3) a direct texture classification using deep learning technology. All three methods result in comparable overall quality allowing automated detection of lobular structures with minor advantage in sensitivity (approach 3), specificity (approach 2), or processing time (approach 1). Combining the outputs of the approaches further improved the precision. Different approaches of automated ROI detection are feasible and should be selected according to the individual needs of biomarker research. Additionally, detected ROIs could be used as a basis for quantification of immune infiltration in lobular structures. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Rapid and label-free bioanalytical method of alpha fetoprotein detection using LSPR chip

    NASA Astrophysics Data System (ADS)

    Kim, Dongjoo; Kim, Jinwoon; Kwak, Cheol Hwan; Heo, Nam Su; Oh, Seo Yeong; Lee, Hoomin; Lee, Go-Woon; Vilian, A. T. Ezhil; Han, Young-Kyu; Kim, Woo-Sik; Kim, Gi-bum; Kwon, Soonjo; Huh, Yun Suk

    2017-07-01

    Alpha fetoprotein (AFP) is a cancer marker, particularly for hepatocellular carcinoma. Normal levels of AFP are less than 20 ng/mL; however, its levels can reach more than 400 ng/mL in patients with HCC. Enzyme linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) have been employed for clinical diagnosis of AFP; however, these methods are time consuming and labor intensive. In this study, we developed a localized surface plasmon resonance (LSPR) based biosensor for simple and rapid detection of AFP. This biosensor consists of a UV-Vis spectrometer, a cuvette cell, and a biosensor chip nanopatterned with gold nanoparticles (AuNPs). In our LSPR biosensor, binding of AFP to the surface of the sensor chip led to an increasing magnitude of the LSPR signals, which was measured by an ultraviolet-visible (UV-Vis) spectrometer. Our LSPR biosensor showed sufficient detectability of AFP at concentrations of 1 ng/mL to 1 μg/mL. Moreover, the overall procedure for detection of AFP was completed within 20 min. This biosensor could also be utilized for a point of care test (POCT) by employing a portable UV-Vis spectrometer. Owing to the simplicity and rapidity of the detection process, our LSPR biosensor is expected to replace traditional diagnostic methods for the early detection of diseases.

  1. Surface enhanced Raman scattering (SERS) spectra of trinitrotoluene in silver colloids prepared by microwave heating method.

    PubMed

    Zhang, Chunling; Wang, Kaijun; Han, Dejun; Pang, Qing

    2014-03-25

    Surface enhanced Raman spectroscopy (SERS) has been demonstrated for the detection of trace levels of explosives due to its high sensitivity, speed of detection and fingerprint feature. 2,4,6-Trinitrotoluene (TNT), a leading example of nitroaromatic explosives, is causing wide concern. In this study, SERS spectra of TNT solution in silver colloids have been successfully measured and a comparison was drawn with the normal Raman spectra of bulk TNT. The silver colloids were prepared by the microwave heating method and characterized by UV-Vis spectra and the scanning electron microscopy (SEM). NaCl and pH value have a great impact on SERS intensity of TNT, the corresponding experimental research results and theoretical interpretations were further illustrated to a certain extent. Moreover, the detection limit of TNT in aqueous solution was achieved as low as 10(-10) mol L(-1) and some preliminary experiments of detecting TNT vapor (about 10 μg/L) using SERS have been carried out. Our results demonstrated the potential of SERS for probing TNT with high sensitivity, and suggest SERS as a powerful method for detection of TNT and similar species at trace levels. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Subliminal Salience Search Illustrated: EEG Identity and Deception Detection on the Fringe of Awareness

    PubMed Central

    Bowman, Howard; Filetti, Marco; Janssen, Dirk; Su, Li; Alsufyani, Abdulmajeed; Wyble, Brad

    2013-01-01

    We propose a novel deception detection system based on Rapid Serial Visual Presentation (RSVP). One motivation for the new method is to present stimuli on the fringe of awareness, such that it is more difficult for deceivers to confound the deception test using countermeasures. The proposed system is able to detect identity deception (by using the first names of participants) with a 100% hit rate (at an alpha level of 0.05). To achieve this, we extended the classic Event-Related Potential (ERP) techniques (such as peak-to-peak) by applying Randomisation, a form of Monte Carlo resampling, which we used to detect deception at an individual level. In order to make the deployment of the system simple and rapid, we utilised data from three electrodes only: Fz, Cz and Pz. We then combined data from the three electrodes using Fisher's method so that each participant was assigned a single p-value, which represents the combined probability that a specific participant was being deceptive. We also present subliminal salience search as a general method to determine what participants find salient by detecting breakthrough into conscious awareness using EEG. PMID:23372697

  3. Development of a database and processing method for detecting hematotoxicity adverse drug events.

    PubMed

    Shimai, Yoshie; Takeda, Toshihiro; Manabe, Shirou; Teramoto, Kei; Mihara, Naoki; Matsumura, Yasushi

    2015-01-01

    Adverse events are detected by monitoring the patient's status, including blood test results. However, it is difficult to identify all adverse events based on recognition by individual doctors. We developed a system that can be used to detect hematotoxicity adverse events according to blood test results recorded in an electronic medical record system. The blood test results were graded based on Common Terminology Criteria for Adverse Events (CTCAE) and changes in the blood test results (Up, Down, Flat) were assessed according to the variation in the grade. The changes in the blood test and injection data were stored in a database. By comparing the date of injection and start and end dates of the change in the blood test results, adverse events related to a designated drug were detected. Using this method, we searched for the occurrence of serious adverse events (CTCAE Grades 3 or 4) concerning WBC, ALT and creatinine related to paclitaxel at Osaka University Hospital. The rate of occurrence of a decreased WBC count, increased ALT level and increased creatinine level was 36.0%, 0.6% and 0.4%, respectively. This method is useful for detecting and estimating the rate of occurrence of hematotoxicity adverse drug events.

  4. Blastocystis sp. in Irritable Bowel Syndrome (IBS)--Detection in Stool Aspirates during Colonoscopy.

    PubMed

    Ragavan, Nanthiney Devi; Kumar, Suresh; Chye, Tan Tian; Mahadeva, Sanjiv; Shiaw-Hooi, Ho

    2015-01-01

    Blastocystis is one of the most common gut parasites found in the intestinal tract of humans and animals. Its' association with IBS is controversial, possibly as a result of irregular shedding of parasites in stool and variation in stool detection. We aimed to screen for Blastocystis in colonic stool aspirate samples in adult patients with and without IBS undergoing colonoscopy for various indications and measure the interleukin levels (IL-8, IL-3 and IL-5). In addition to standard stool culture techniques, polymerase chain reaction (PCR) techniques were employed to detect and subtype Blastocystis. All the serum samples collected were subjected for ELISA studies to measure the interleukin levels (IL-8, IL-3 and IL-5). Among 109 (IBS n = 35 and non-IBS n = 74) adults, direct stool examination and culture of colonic aspirates were initially negative for Blastocystis. However, PCR analysis detected Blastocystis in 6 (17%) IBS and 4 (5.5%) non-IBS patients. In the six positive IBS patients by PCR method, subtype 3 was shown to be the most predominant (3/6: 50%) followed by subtype 4 (2/6; 33.3%) and subtype 5 (1/6; 16.6%). IL-8 levels were significantly elevated in the IBS Blasto group and IBS group (p<0.05) compared to non-IBS and non-IBS Blasto group. The level of IL-3 in were seen to be significantly higher in than IBS Blasto group and IBS group (p<0.05) compared to non-IBS. Meanwhile, the IL-5 levels were significantly higher in IBS Blasto group (p<0.05) compared to non-IBS and non-IBS Blasto group. This study implicates that detecting Blastosystis by PCR method using colonic aspirate samples during colonoscopy, suggests that this may be a better method for sample collection due to the parasite's irregular shedding in Blastocystis-infected stools. Patients with IBS infected with parasite showed an increase in the interleukin levels demonstrate that Blastocystis does have an effect in the immune system.

  5. Rapid Surface Detection of CO2 Leaks from Geologic Sequestration Sites

    NASA Astrophysics Data System (ADS)

    Moriarty, D. M.; Krevor, S. C.; Benson, S. M.

    2013-12-01

    Carbon sequestration is becoming a viable option for global CO2 mitigation but effective monitoring methods are needed assure the carbon dioxide stays underground. Above surface monitoring using a mobile gas analyzer is one such method (e.g. Krevor et al., 2010). The Picarro gas analyzer uses wavelength-scanned cavity ring down spectroscopy to accurately identify concentrations of various atmospheric gases including their isotopic composition. These measurements can then be used for anomaly (leak) detection and source attribution. Leaks are detected by anomalous absolute concentration of CO2 and anomalous δ13C values. Source attribution is determined by the isotopic concentrations of the identified leaking gas. To distinguish between noise from ambient signals and leaks, a method based on mixing ratios has been developed. A newly acquired data set presented here has been collected from a 3.7km2 area with naturally occurring CO2 springs near Green River, Utah. All of the areas of known leakage were readily detected using this method along with several other areas that showed significant signs of leakage. In addition, testing on the Stanford campus has shown that this method is sensitive enough to distinguish between open fields and roadways. Another data set is being collected at Montana State University at the ZERT monitoring test site where an artificial leak has been created for the purpose of testing leak detection and quantification methods. Data collected from this site are being used for (1) assessing of detection levels and how they depend on environmental parameters such as wind speed, and acquisition variables such as sample rate and traverse speed, (2) optimizing acquisition parameters to increase detection levels and increase confidence in leak detection, (3) evaluating the potential for quantifying the magnitude of the leak and (4) spatial data analysis to identify the most probable leak locations.

  6. Multispectral image fusion for target detection

    NASA Astrophysics Data System (ADS)

    Leviner, Marom; Maltz, Masha

    2009-09-01

    Various different methods to perform multi-spectral image fusion have been suggested, mostly on the pixel level. However, the jury is still out on the benefits of a fused image compared to its source images. We present here a new multi-spectral image fusion method, multi-spectral segmentation fusion (MSSF), which uses a feature level processing paradigm. To test our method, we compared human observer performance in an experiment using MSSF against two established methods: Averaging and Principle Components Analysis (PCA), and against its two source bands, visible and infrared. The task that we studied was: target detection in the cluttered environment. MSSF proved superior to the other fusion methods. Based on these findings, current speculation about the circumstances in which multi-spectral image fusion in general and specific fusion methods in particular would be superior to using the original image sources can be further addressed.

  7. Electrochemical Detection of Ultratrace (Picomolar) Levels of Hg2+ Using a Silver Nanoparticle-Modified Glassy Carbon Electrode.

    PubMed

    Suherman, Alex L; Ngamchuea, Kamonwad; Tanner, Eden E L; Sokolov, Stanislav V; Holter, Jennifer; Young, Neil P; Compton, Richard G

    2017-07-05

    Ultratrace levels of Hg 2+ have been quantified by undertaking linear sweep voltammetry with a silver nanoparticle-modified glassy carbon electrode (AgNP-GCE) in aqueous solutions containing Hg 2+ . This is achieved by monitoring the change in the silver stripping peak with Hg 2+ concentration resulting from the galvanic displacement of silver by mercury: Ag(np) + 1/2Hg 2+ (aq) → Ag + (aq) + 1/2Hg(l). This facile and reproducible detection method exhibits an excellent linear dynamic range of 100.0 pM to 10.0 nM Hg 2+ concentration with R 2 = 0.982. The limit of detection (LoD) based on 3σ is 28 pM Hg 2+ , while the lowest detectable level for quantification purposes is 100.0 pM. This method is appropriate for routine environmental monitoring and drinking water quality assessment since the guideline value set by the US Environmental Protection Agency (EPA) for inorganic mercury in drinking water is 0.002 mg L -1 (10 nM).

  8. Development of a Sensitive Luciferase-Based Sandwich ELISA System for the Detection of Human Extracellular Matrix 1 Protein.

    PubMed

    Li, Ya; Li, Yanqing; Zhao, Junli; Zheng, Xiaojing; Mao, Qinwen; Xia, Haibin

    2016-12-01

    Enzyme-linked immunosorbent assay (ELISA) has been one of the main methods for detecting an antigen in an aqueous sample for more than four decades. Nowadays, one of the biggest concerns for ELISA is still how to improve the sensitivity of the assay, and the luciferase-luciferin reaction system has been noticed as a new detection method with high sensitivity. In this study, a luciferin-luciferase reaction system was used as the detection method for a sandwich ELISA system. It was shown that this new system led to an increase in the detection sensitivity of at least two times when compared with the traditional horseradish peroxidase (HRP) detection method. Lastly, the serum levels of the human extracellular matrix 1 protein of breast cancer patients were determined by the new system, which were overall similar to the HRP chemiluminescent system. Furthermore, this new luciferase reporter can be implemented into other ELISA systems for the purpose of increasing the assay sensitivity.

  9. Radiometric liquid level gauge with linear-detection (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glaeser, M.; Emmelmann, K.P.

    1973-09-01

    A description is given of a radiometric liquid level gauge with linear detection. It consists of a set of radioactive sources (e.g., /sup 137/Cs) with quadratic graduation in their activities, of a scintillation counter with electronic back-up unit and of a slender tube. The tube, sources and scintillation counter form a compact snd easily transportsble liquid level gauge. It is-especially adapted for liquid level measurements in slender, difficulty accessible and opaque containers. The device supplements the different methods for liquid level measurement with a new variant which is adopted for many cases in practice. (auth)

  10. Experimental estimation of snare detectability for robust threat monitoring.

    PubMed

    O'Kelly, Hannah J; Rowcliffe, J Marcus; Durant, Sarah; Milner-Gulland, E J

    2018-02-01

    Hunting with wire snares is rife within many tropical forest systems, and constitutes one of the severest threats to a wide range of vertebrate taxa. As for all threats, reliable monitoring of snaring levels is critical for assessing the relative effectiveness of management interventions. However, snares pose a particular challenge in terms of tracking spatial or temporal trends in their prevalence because they are extremely difficult to detect, and are typically spread across large, inaccessible areas. As with cryptic animal targets, any approach used to monitor snaring levels must address the issue of imperfect detection, but no standard method exists to do so. We carried out a field experiment in Keo Seima Wildlife Reserve in eastern Cambodia with the following objectives: (1) To estimate the detection probably of wire snares within a tropical forest context, and to investigate how detectability might be affected by habitat type, snare type, or observer. (2) To trial two sets of sampling protocols feasible to implement in a range of challenging field conditions. (3) To conduct a preliminary assessment of two potential analytical approaches to dealing with the resulting snare encounter data. We found that although different observers had no discernible effect on detection probability, detectability did vary between habitat type and snare type. We contend that simple repeated counts carried out at multiple sites and analyzed using binomial mixture models could represent a practical yet robust solution to the problem of monitoring snaring levels both inside and outside of protected areas. This experiment represents an important first step in developing improved methods of threat monitoring, and such methods are greatly needed in southeast Asia, as well as in as many other regions.

  11. Excreted Thiocyanate Detects Live Reef Fishes Illegally Collected Using Cyanide—A Non-Invasive and Non-Destructive Testing Approach

    PubMed Central

    Vaz, Marcela C. M.; Rocha-Santos, Teresa A. P.; Rocha, Rui J. M.; Lopes, Isabel; Pereira, Ruth; Duarte, Armando C.; Rubec, Peter J.; Calado, Ricardo

    2012-01-01

    Cyanide fishing is a method employed to capture marine fish alive on coral reefs. They are shipped to markets for human consumption in Southeast Asia, as well as to supply the marine aquarium trade worldwide. Although several techniques can be used to detect cyanide in reef fish, there is still no testing method that can be used to survey the whole supply chain. Most methods for cyanide detection are time-consuming and require the sacrifice of the sampled fish. Thiocyanate anion (SCN−) is a metabolite produced by the main metabolic pathway for cyanide anion (CN−) detoxification. Our study employed an optical fiber (OF) methodology (analytical time <6 min) to detect SCN− in a non-invasive and non-destructive manner. Our OF methodology is able to detect trace levels (>3.16 µg L−1) of SCN− in seawater. Given that marine fish exposed to cyanide excrete SCN− in the urine, elevated levels of SCN− present in the seawater holding live reef fish indicate that the surveyed specimens were likely exposed to cyanide. In our study, captive-bred clownfish (Amphiprion clarkii) pulse exposed for 60 s to either 12.5 or 25 mg L−1 of CN− excreted up to 6.96±0.03 and 9.84±0.03 µg L−1 of SCN−, respectively, during the 28 days following exposure. No detectable levels of SCN− were recorded in the water holding control organisms not exposed to CN−, or in synthetic seawater lacking fish. While further research is necessary, our methodology can allow a rapid detection of SCN− in the holding water and can be used as a screening tool to indicate if live reef fish were collected with cyanide. PMID:22536375

  12. Hotspot detection using space-time scan statistics on children under five years of age in Depok

    NASA Astrophysics Data System (ADS)

    Verdiana, Miranti; Widyaningsih, Yekti

    2017-03-01

    Some problems that affect the health level in Depok is the high malnutrition rates from year to year and the more spread infectious and non-communicable diseases in some areas. Children under five years old is a vulnerable part of population to get the malnutrition and diseases. Based on this reason, it is important to observe the location and time, where and when, malnutrition in Depok happened in high intensity. To obtain the location and time of the hotspots of malnutrition and diseases that attack children under five years old, space-time scan statistics method can be used. Space-time scan statistic is a hotspot detection method, where the area and time of information and time are taken into account simultaneously in detecting the hotspots. This method detects a hotspot with a cylindrical scanning window: the cylindrical pedestal describes the area, and the height of cylinder describe the time. Cylinders formed is a hotspot candidate that may occur, which require testing of hypotheses, whether a cylinder can be summed up as a hotspot. Hotspot detection in this study carried out by forming a combination of several variables. Some combination of variables provides hotspot detection results that tend to be the same, so as to form groups (clusters). In the case of infant health level in Depok city, Beji health care center region in 2011-2012 is a hotspot. According to the combination of the variables used in the detection of hotspots, Beji health care center is most frequently as a hotspot. Hopefully the local government can take the right policy to improve the health level of children under five in the city of Depok.

  13. Excreted thiocyanate detects live reef fishes illegally collected using cyanide--a non-invasive and non-destructive testing approach.

    PubMed

    Vaz, Marcela C M; Rocha-Santos, Teresa A P; Rocha, Rui J M; Lopes, Isabel; Pereira, Ruth; Duarte, Armando C; Rubec, Peter J; Calado, Ricardo

    2012-01-01

    Cyanide fishing is a method employed to capture marine fish alive on coral reefs. They are shipped to markets for human consumption in Southeast Asia, as well as to supply the marine aquarium trade worldwide. Although several techniques can be used to detect cyanide in reef fish, there is still no testing method that can be used to survey the whole supply chain. Most methods for cyanide detection are time-consuming and require the sacrifice of the sampled fish. Thiocyanate anion (SCN(-)) is a metabolite produced by the main metabolic pathway for cyanide anion (CN(-)) detoxification. Our study employed an optical fiber (OF) methodology (analytical time <6 min) to detect SCN(-) in a non-invasive and non-destructive manner. Our OF methodology is able to detect trace levels (>3.16 µg L(-1)) of SCN(-) in seawater. Given that marine fish exposed to cyanide excrete SCN(-) in the urine, elevated levels of SCN(-) present in the seawater holding live reef fish indicate that the surveyed specimens were likely exposed to cyanide. In our study, captive-bred clownfish (Amphiprion clarkii) pulse exposed for 60 s to either 12.5 or 25 mg L(-1) of CN(-) excreted up to 6.96±0.03 and 9.84±0.03 µg L(-1) of SCN(-), respectively, during the 28 days following exposure. No detectable levels of SCN(-) were recorded in the water holding control organisms not exposed to CN(-), or in synthetic seawater lacking fish. While further research is necessary, our methodology can allow a rapid detection of SCN(-) in the holding water and can be used as a screening tool to indicate if live reef fish were collected with cyanide.

  14. Development and application of a selective detection method for genetically modified soy and soy-derived products.

    PubMed

    Hoef, A M; Kok, E J; Bouw, E; Kuiper, H A; Keijer, J

    1998-10-01

    A method has been developed to distinguish between traditional soy beans and transgenic Roundup Ready soy beans, i.e. the glyphosate ('Roundup') resistant soy bean variety developed by Monsanto Company. Glyphosate resistance results from the incorporation of an Agrobacterium-derived 5-enol-pyruvyl-shikimate-3-phosphatesynthase (EPSPS) gene. The detection method developed is based on a nested Polymerase Chain Reaction (PCR) procedure. Ten femtograms of soy bean DNA can be detected, while, starting from whole soy beans, Roundup Ready DNA can be detected at a level of 1 Roundup Ready soy bean in 5000 non-GM soy beans (0.02% Roundup Ready soy bean). The method has been applied to samples of soy bean, soy-meal pellets and soy bean flour, as well as a number of processed complex products such as infant formula based on soy, tofu, tempeh, soy-based desserts, bakery products and complex meat and meat-replacing products. The results obtained are discussed with respect to practical application of the detection method developed.

  15. Ship Detection Based on Multiple Features in Random Forest Model for Hyperspectral Images

    NASA Astrophysics Data System (ADS)

    Li, N.; Ding, L.; Zhao, H.; Shi, J.; Wang, D.; Gong, X.

    2018-04-01

    A novel method for detecting ships which aim to make full use of both the spatial and spectral information from hyperspectral images is proposed. Firstly, the band which is high signal-noise ratio in the range of near infrared or short-wave infrared spectrum, is used to segment land and sea on Otsu threshold segmentation method. Secondly, multiple features that include spectral and texture features are extracted from hyperspectral images. Principal components analysis (PCA) is used to extract spectral features, the Grey Level Co-occurrence Matrix (GLCM) is used to extract texture features. Finally, Random Forest (RF) model is introduced to detect ships based on the extracted features. To illustrate the effectiveness of the method, we carry out experiments over the EO-1 data by comparing single feature and different multiple features. Compared with the traditional single feature method and Support Vector Machine (SVM) model, the proposed method can stably achieve the target detection of ships under complex background and can effectively improve the detection accuracy of ships.

  16. A dual validation approach to detect anthelmintic residues in bovine liver over an extended concentration range

    USDA-ARS?s Scientific Manuscript database

    This paper describes a method for the detection and quantification of 38 of the most widely used anthelmintics (including benzimidazoles, macrocyclic lactones and flukicides) in bovine liver at MRL and non-MRL level. A dual validation approach was adapted to reliably detect anthelmintic residues ov...

  17. Variability of individual genetic load: consequences for the detection of inbreeding depression.

    PubMed

    Restoux, Gwendal; Huot de Longchamp, Priscille; Fady, Bruno; Klein, Etienne K

    2012-03-01

    Inbreeding depression is a key factor affecting the persistence of natural populations, particularly when they are fragmented. In species with mixed mating systems, inbreeding depression can be estimated at the population level by regressing the average progeny fitness by the selfing rate of their mothers. We applied this method using simulated populations to investigate how population genetic parameters can affect the detection power of inbreeding depression. We simulated individual selfing rates and genetic loads from which we computed fitness values. The regression method yielded high statistical power, inbreeding depression being detected as significant (5 % level) in 92 % of the simulations. High individual variation in selfing rate and high mean genetic load led to better detection of inbreeding depression while high among-individual variation in genetic load made it more difficult to detect inbreeding depression. For a constant sampling effort, increasing the number of progenies while decreasing the number of individuals per progeny enhanced the detection power of inbreeding depression. We discuss the implication of among-mother variability of genetic load and selfing rate on inbreeding depression studies.

  18. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment

    PubMed Central

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-01-01

    Digital PCR has developed rapidly since it was first reported in the 1990s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products. PMID:26239916

  19. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment.

    PubMed

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-08-04

    Digital PCR has developed rapidly since it was first reported in the 1990 s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products.

  20. Posture Detection Based on Smart Cushion for Wheelchair Users

    PubMed Central

    Ma, Congcong; Li, Wenfeng; Gravina, Raffaele; Fortino, Giancarlo

    2017-01-01

    The postures of wheelchair users can reveal their sitting habit, mood, and even predict health risks such as pressure ulcers or lower back pain. Mining the hidden information of the postures can reveal their wellness and general health conditions. In this paper, a cushion-based posture recognition system is used to process pressure sensor signals for the detection of user’s posture in the wheelchair. The proposed posture detection method is composed of three main steps: data level classification for posture detection, backward selection of sensor configuration, and recognition results compared with previous literature. Five supervised classification techniques—Decision Tree (J48), Support Vector Machines (SVM), Multilayer Perceptron (MLP), Naive Bayes, and k-Nearest Neighbor (k-NN)—are compared in terms of classification accuracy, precision, recall, and F-measure. Results indicate that the J48 classifier provides the highest accuracy compared to other techniques. The backward selection method was used to determine the best sensor deployment configuration of the wheelchair. Several kinds of pressure sensor deployments are compared and our new method of deployment is shown to better detect postures of the wheelchair users. Performance analysis also took into account the Body Mass Index (BMI), useful for evaluating the robustness of the method across individual physical differences. Results show that our proposed sensor deployment is effective, achieving 99.47% posture recognition accuracy. Our proposed method is very competitive for posture recognition and robust in comparison with other former research. Accurate posture detection represents a fundamental basic block to develop several applications, including fatigue estimation and activity level assessment. PMID:28353684

  1. The analysis of tetracyclines, quinolones, macrolides, lincosamides, pleuromutilins, and sulfonamides in chicken feathers using UHPLC-MS/MS in order to monitor antibiotic use in the poultry sector.

    PubMed

    Jansen, Larissa J M; Bolck, Yvette J C; Rademaker, Janneau; Zuidema, Tina; Berendsen, Bjorn J A

    2017-08-01

    In The Netherlands, all antibiotic treatments should be registered at the farm and in a central database. To enforce correct antibiotic use and registration, and to enforce prudent use of antibiotics, there is a need for methods that are able to detect antibiotic treatments. Ideally, such a method is able to detect antibiotic applications during the entire lifespan of an animal, including treatments administered during the first days of the animals' lives. Monitoring tissue, as is common practice, only provides a limited window of opportunity, as residue levels in tissue soon drop below measurable quantities. The analysis of feathers proves to be a promising tool in this respect. Furthermore, a qualitative confirmatory method was developed for the analyses of six major groups of antibiotics in ground chicken feathers, aiming for a detection limit as low as reasonably possible. The method was validated according to Commission Decision 2002/657/EC. All compounds comply with the criteria and, as a matter of fact, 58% of the compounds could also be quantified according to regulations. Additionally, we demonstrated that a less laborious method, in which whole feathers were analyzed, proved successful in the detection of applied antibiotics. Most compounds could be detected at levels of 2 μg kg -1 or below with the exception of sulfachloropyridazine, tylosin, and tylvalosin. This demonstrates the effectiveness of feather analysis to detect antibiotic use to allow effective enforcement of antibiotic use and prevent the illegal, off-label, and nonregistered use of antibiotics.

  2. Syndromic surveillance for health information system failures: a feasibility study.

    PubMed

    Ong, Mei-Sing; Magrabi, Farah; Coiera, Enrico

    2013-05-01

    To explore the applicability of a syndromic surveillance method to the early detection of health information technology (HIT) system failures. A syndromic surveillance system was developed to monitor a laboratory information system at a tertiary hospital. Four indices were monitored: (1) total laboratory records being created; (2) total records with missing results; (3) average serum potassium results; and (4) total duplicated tests on a patient. The goal was to detect HIT system failures causing: data loss at the record level; data loss at the field level; erroneous data; and unintended duplication of data. Time-series models of the indices were constructed, and statistical process control charts were used to detect unexpected behaviors. The ability of the models to detect HIT system failures was evaluated using simulated failures, each lasting for 24 h, with error rates ranging from 1% to 35%. In detecting data loss at the record level, the model achieved a sensitivity of 0.26 when the simulated error rate was 1%, while maintaining a specificity of 0.98. Detection performance improved with increasing error rates, achieving a perfect sensitivity when the error rate was 35%. In the detection of missing results, erroneous serum potassium results and unintended repetition of tests, perfect sensitivity was attained when the error rate was as small as 5%. Decreasing the error rate to 1% resulted in a drop in sensitivity to 0.65-0.85. Syndromic surveillance methods can potentially be applied to monitor HIT systems, to facilitate the early detection of failures.

  3. A biomolecular detection method based on charge pumping in a nanogap embedded field-effect-transistor biosensor

    NASA Astrophysics Data System (ADS)

    Kim, Sungho; Ahn, Jae-Hyuk; Park, Tae Jung; Lee, Sang Yup; Choi, Yang-Kyu

    2009-06-01

    A unique direct electrical detection method of biomolecules, charge pumping, was demonstrated using a nanogap embedded field-effect-transistor (FET). With aid of a charge pumping method, sensitivity can fall below the 1 ng/ml concentration regime in antigen-antibody binding of an avian influenza case. Biomolecules immobilized in the nanogap are mainly responsible for the acute changes of the interface trap density due to modulation of the energy level of the trap. This finding is supported by a numerical simulation. The proposed detection method for biomolecules using a nanogap embedded FET represents a foundation for a chip-based biosensor capable of high sensitivity.

  4. Machine Learning Methods for Attack Detection in the Smart Grid.

    PubMed

    Ozay, Mete; Esnaola, Inaki; Yarman Vural, Fatos Tunay; Kulkarni, Sanjeev R; Poor, H Vincent

    2016-08-01

    Attack detection problems in the smart grid are posed as statistical learning problems for different attack scenarios in which the measurements are observed in batch or online settings. In this approach, machine learning algorithms are used to classify measurements as being either secure or attacked. An attack detection framework is provided to exploit any available prior knowledge about the system and surmount constraints arising from the sparse structure of the problem in the proposed approach. Well-known batch and online learning algorithms (supervised and semisupervised) are employed with decision- and feature-level fusion to model the attack detection problem. The relationships between statistical and geometric properties of attack vectors employed in the attack scenarios and learning algorithms are analyzed to detect unobservable attacks using statistical learning methods. The proposed algorithms are examined on various IEEE test systems. Experimental analyses show that machine learning algorithms can detect attacks with performances higher than attack detection algorithms that employ state vector estimation methods in the proposed attack detection framework.

  5. Rapid method for monitoring N-nitrosodimethylamine in drinking water at the ng/L level without pre-concentration using high-performance liquid chromatography-chemiluminescence detection.

    PubMed

    Kodamatani, Hitoshi; Yamasaki, Hitomi; Sakaguchi, Takeru; Itoh, Shinya; Iwaya, Yoshimi; Saga, Makoto; Saito, Keiitsu; Kanzaki, Ryo; Tomiyasu, Takashi

    2016-08-19

    As a contaminant in drinking water, N-nitrosodimethylamine (NDMA) is of great concern because of its carcinogenicity; it has been limited to levels of ng/L by regulatory bodies worldwide. Consequently, a rapid and sensitive method for monitoring NDMA in drinking water is urgently required. In this study, we report an improvement of our previously proposed HPLC-based system for NDMA determination. The approach consists of the HPLC separation of NDMA, followed by NDMA photolysis to form peroxynitrite and detection with a luminol chemiluminescence reaction. The detection limit for the improved HPLC method was 0.2ng/L, which is 10 times more sensitive than our previously reported system. For tap water measurements, only the addition of an ascorbic acid solution to eliminate residual chlorine and passage through an Oasis MAX solid-phase extraction cartridge are needed. The proposed NDMA determination method requires a sample volume of less than 2mL and a complete analysis time of less than 15min per sample. The method was utilized for the long-term monitoring of NDMA in tap water. The NDMA level measured in the municipal water survey was 4.9ng/L, and a seasonal change of the NDMA concentration in tap water was confirmed. The proposed method should constitute a useful NDMA monitoring method for protecting drinking water quality. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. One-Step Immunochromatography Assay Kit for Detecting Antibodies to Canine Parvovirus

    PubMed Central

    Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub

    2006-01-01

    This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the “gold standard.” These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited. PMID:16603622

  7. One-step immunochromatography assay kit for detecting antibodies to canine parvovirus.

    PubMed

    Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub

    2006-04-01

    This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the "gold standard." These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited.

  8. Effect of processing on recovery and variability associated with immunochemical analytical methods for multiple allergens in a single matrix: sugar cookies.

    PubMed

    Khuda, Sefat; Slate, Andrew; Pereira, Marion; Al-Taher, Fadwa; Jackson, Lauren; Diaz-Amigo, Carmen; Bigley, Elmer C; Whitaker, Thomas; Williams, Kristina M

    2012-05-02

    Among the major food allergies, peanut, egg, and milk are the most common. The immunochemical detection of food allergens depends on various factors, such as the food matrix and processing method, which can affect allergen conformation and extractability. This study aimed to (1) develop matrix-specific incurred reference materials for allergen testing, (2) determine whether multiple allergens in the same model food can be simultaneously detected, and (3) establish the effect of processing on reference material stability and allergen detection. Defatted peanut flour, whole egg powder, and spray-dried milk were added to cookie dough at seven incurred levels before baking. Allergens were measured using five commercial enzyme-linked immunosorbent assay (ELISA) kits. All kits showed decreased recovery of all allergens after baking. Analytical coefficients of variation for most kits increased with baking time, but decreased with incurred allergen level. Thus, food processing negatively affects the recovery and variability of peanut, egg, and milk detection in a sugar cookie matrix when using immunochemical methods.

  9. The determination of fenspiride in human plasma and urine by liquid chromatography with electrochemical or ultraviolet detection.

    PubMed

    Sauveur, C; Baune, A; Vergnes, N; Jeanniot, J P

    1989-01-01

    A selective and sensitive method for the determination of fenspiride in biological fluids is described. The method involves liquid-liquid extraction followed by separation on a reversed-phase column with electrochemical detection for low levels of the drug in plasma (less than or equal to 100 ng ml-1) or UV absorption for higher concentrations in plasma or urine. The method is suitable for pharmacokinetic analyses and drug monitoring studies.

  10. Proteomic methods for analysis of S-nitrosation⋄

    PubMed Central

    Kettenhofen, Nicholas; Broniowska, Katarzyna; Keszler, Agnes; Zhang, Yanhong; Hogg, Neil

    2007-01-01

    This review discusses proteomic methods to detect and identify S-nitrosated proteins. Protein S-nitrosation, the post-translational modification of thiol residues to form S-nitrosothiols, has been suggested to be a mechanism of cellular redox signaling by which nitric oxide can alter cellular function through modification of protein thiol residues. It has become apparent that methods that will detect and identify low levels of S-nitrosated protein in complex protein mixtures are required in order to fully appreciate the range, extent and selectivity of this modification in both physiological and pathological conditions. While many advances have been made in the detection of either total cellular S-nitrosation or individual S-nitrosothiols, proteomic methods for the detection of S-nitrosation are in relative infancy. This review will discuss the major methods that have been used for the proteomic analysis of protein S-nitrosation and discuss the pros and cons of this methodology. PMID:17360249

  11. [Optimized application of nested PCR method for detection of malaria].

    PubMed

    Yao-Guang, Z; Li, J; Zhen-Yu, W; Li, C

    2017-04-28

    Objective To optimize the application of the nested PCR method for the detection of malaria according to the working practice, so as to improve the efficiency of malaria detection. Methods Premixing solution of PCR, internal primers for further amplification and new designed primers that aimed at two Plasmodium ovale subspecies were employed to optimize the reaction system, reaction condition and specific primers of P . ovale on basis of routine nested PCR. Then the specificity and the sensitivity of the optimized method were analyzed. The positive blood samples and examination samples of malaria were detected by the routine nested PCR and the optimized method simultaneously, and the detection results were compared and analyzed. Results The optimized method showed good specificity, and its sensitivity could reach the pg to fg level. The two methods were used to detect the same positive malarial blood samples simultaneously, the results indicated that the PCR products of the two methods had no significant difference, but the non-specific amplification reduced obviously and the detection rates of P . ovale subspecies improved, as well as the total specificity also increased through the use of the optimized method. The actual detection results of 111 cases of malarial blood samples showed that the sensitivity and specificity of the routine nested PCR were 94.57% and 86.96%, respectively, and those of the optimized method were both 93.48%, and there was no statistically significant difference between the two methods in the sensitivity ( P > 0.05), but there was a statistically significant difference between the two methods in the specificity ( P < 0.05). Conclusion The optimized PCR can improve the specificity without reducing the sensitivity on the basis of the routine nested PCR, it also can save the cost and increase the efficiency of malaria detection as less experiment links.

  12. Fault detection in reciprocating compressor valves under varying load conditions

    NASA Astrophysics Data System (ADS)

    Pichler, Kurt; Lughofer, Edwin; Pichler, Markus; Buchegger, Thomas; Klement, Erich Peter; Huschenbett, Matthias

    2016-03-01

    This paper presents a novel approach for detecting cracked or broken reciprocating compressor valves under varying load conditions. The main idea is that the time frequency representation of vibration measurement data will show typical patterns depending on the fault state. The problem is to detect these patterns reliably. For the detection task, we make a detour via the two dimensional autocorrelation. The autocorrelation emphasizes the patterns and reduces noise effects. This makes it easier to define appropriate features. After feature extraction, classification is done using logistic regression and support vector machines. The method's performance is validated by analyzing real world measurement data. The results will show a very high detection accuracy while keeping the false alarm rates at a very low level for different compressor loads, thus achieving a load-independent method. The proposed approach is, to our best knowledge, the first automated method for reciprocating compressor valve fault detection that can handle varying load conditions.

  13. Automated detection of red lesions from digital colour fundus photographs.

    PubMed

    Jaafar, Hussain F; Nandi, Asoke K; Al-Nuaimy, Waleed

    2011-01-01

    Earliest signs of diabetic retinopathy, the major cause of vision loss, are damage to the blood vessels and the formation of lesions in the retina. Early detection of diabetic retinopathy is essential for the prevention of blindness. In this paper we present a computer-aided system to automatically identify red lesions from retinal fundus photographs. After pre-processing, a morphological technique was used to segment red lesion candidates from the background and other retinal structures. Then a rule-based classifier was used to discriminate actual red lesions from artifacts. A novel method for blood vessel detection is also proposed to refine the detection of red lesions. For a standarised test set of 219 images, the proposed method can detect red lesions with a sensitivity of 89.7% and a specificity of 98.6% (at lesion level). The performance of the proposed method shows considerable promise for detection of red lesions as well as other types of lesions.

  14. High accuracy position method based on computer vision and error analysis

    NASA Astrophysics Data System (ADS)

    Chen, Shihao; Shi, Zhongke

    2003-09-01

    The study of high accuracy position system is becoming the hotspot in the field of autocontrol. And positioning is one of the most researched tasks in vision system. So we decide to solve the object locating by using the image processing method. This paper describes a new method of high accuracy positioning method through vision system. In the proposed method, an edge-detection filter is designed for a certain running condition. Here, the filter contains two mainly parts: one is image-processing module, this module is to implement edge detection, it contains of multi-level threshold self-adapting segmentation, edge-detection and edge filter; the other one is object-locating module, it is to point out the location of each object in high accurate, and it is made up of medium-filtering and curve-fitting. This paper gives some analysis error for the method to prove the feasibility of vision in position detecting. Finally, to verify the availability of the method, an example of positioning worktable, which is using the proposed method, is given at the end of the paper. Results show that the method can accurately detect the position of measured object and identify object attitude.

  15. Filtering methods in tidal-affected groundwater head measurements: Application of harmonic analysis and continuous wavelet transform

    NASA Astrophysics Data System (ADS)

    Sánchez-Úbeda, Juan Pedro; Calvache, María Luisa; Duque, Carlos; López-Chicano, Manuel

    2016-11-01

    A new methodology has been developed to obtain tidal-filtered time series of groundwater levels in coastal aquifers. Two methods used for oceanography processing and forecasting of sea level data were adapted for this purpose and compared: HA (Harmonic Analysis) and CWT (Continuous Wavelet Transform). The filtering process is generally comprised of two main steps: the detection and fitting of the major tide constituents through the decomposition of the original signal and the subsequent extraction of the complete tidal oscillations. The abilities of the optional HA and CWT methods to decompose and extract the tidal oscillations were assessed by applying them to the data from two piezometers at different depths close to the shoreline of a Mediterranean coastal aquifer (Motril-Salobreña, SE Spain). These methods were applied to three time series of different lengths (one month, one year, and 3.7 years of hourly data) to determine the range of detected frequencies. The different lengths of time series were also used to determine the fit accuracies of the tidal constituents for both the sea level and groundwater heads measurements. The detected tidal constituents were better resolved with increasing depth in the aquifer. The application of these methods yielded a detailed resolution of the tidal components, which enabled the extraction of the major tidal constituents of the sea level measurements from the groundwater heads (e.g., semi-diurnal, diurnal, fortnightly, monthly, semi-annual and annual). In the two wells studied, the CWT method was shown to be a more effective method than HA for extracting the tidal constituents of highest and lowest frequencies from groundwater head measurements.

  16. Automatic detection of aflatoxin contaminated corn kernels using dual-band imagery

    NASA Astrophysics Data System (ADS)

    Ononye, Ambrose E.; Yao, Haibo; Hruska, Zuzana; Kincaid, Russell; Brown, Robert L.; Cleveland, Thomas E.

    2009-05-01

    Aflatoxin is a mycotoxin predominantly produced by Aspergillus flavus and Aspergillus parasitiucus fungi that grow naturally in corn, peanuts and in a wide variety of other grain products. Corn, like other grains is used as food for human and feed for animal consumption. It is known that aflatoxin is carcinogenic; therefore, ingestion of corn infected with the toxin can lead to very serious health problems such as liver damage if the level of the contamination is high. The US Food and Drug Administration (FDA) has strict guidelines for permissible levels in the grain products for both humans and animals. The conventional approach used to determine these contamination levels is one of the destructive and invasive methods that require corn kernels to be ground and then chemically analyzed. Unfortunately, each of the analytical methods can take several hours depending on the quantity, to yield a result. The development of high spectral and spatial resolution imaging sensors has created an opportunity for hyperspectral image analysis to be employed for aflatoxin detection. However, this brings about a high dimensionality problem as a setback. In this paper, we propose a technique that automatically detects aflatoxin contaminated corn kernels by using dual-band imagery. The method exploits the fluorescence emission spectra from corn kernels captured under 365 nm ultra-violet light excitation. Our approach could lead to a non-destructive and non-invasive way of quantifying the levels of aflatoxin contamination. The preliminary results shown here, demonstrate the potential of our technique for aflatoxin detection.

  17. A method of real-time detection for distant moving obstacles by monocular vision

    NASA Astrophysics Data System (ADS)

    Jia, Bao-zhi; Zhu, Ming

    2013-12-01

    In this paper, we propose an approach for detection of distant moving obstacles like cars and bicycles by a monocular camera to cooperate with ultrasonic sensors in low-cost condition. We are aiming at detecting distant obstacles that move toward our autonomous navigation car in order to give alarm and keep away from them. Method of frame differencing is applied to find obstacles after compensation of camera's ego-motion. Meanwhile, each obstacle is separated from others in an independent area and given a confidence level to indicate whether it is coming closer. The results on an open dataset and our own autonomous navigation car have proved that the method is effective for detection of distant moving obstacles in real-time.

  18. Detecting low levels of radionuclides in fluids

    DOEpatents

    Patch, Keith D.; Morgan, Dean T.

    2000-01-01

    An apparatus and method for detecting low levels of one or more radionuclides in a fluid sample uses a substrate that includes an ion exchange resin or other sorbent material to collect the radionuclides. A collecting apparatus includes a collecting chamber that exposes the substrate to a measured amount of the fluid sample such that radionuclides in the fluid sample are collected by the ion exchange resin. A drying apparatus, which can include a drying chamber, then dries the substrate. A measuring apparatus measures emissions from radionuclides collected on the substrate. The substrate is positioned in a measuring chamber proximate to a detector, which provides a signal in response to emissions from the radionuclides. Other analysis methods can be used to detect non-radioactive analytes, which can be collected with other types of sorbent materials.

  19. Using Peptide-Level Proteomics Data for Detecting Differentially Expressed Proteins.

    PubMed

    Suomi, Tomi; Corthals, Garry L; Nevalainen, Olli S; Elo, Laura L

    2015-11-06

    The expression of proteins can be quantified in high-throughput means using different types of mass spectrometers. In recent years, there have emerged label-free methods for determining protein abundance. Although the expression is initially measured at the peptide level, a common approach is to combine the peptide-level measurements into protein-level values before differential expression analysis. However, this simple combination is prone to inconsistencies between peptides and may lose valuable information. To this end, we introduce here a method for detecting differentially expressed proteins by combining peptide-level expression-change statistics. Using controlled spike-in experiments, we show that the approach of averaging peptide-level expression changes yields more accurate lists of differentially expressed proteins than does the conventional protein-level approach. This is particularly true when there are only few replicate samples or the differences between the sample groups are small. The proposed technique is implemented in the Bioconductor package PECA, and it can be downloaded from http://www.bioconductor.org.

  20. Irradiation influence on the detection of genetic-modified soybeans

    NASA Astrophysics Data System (ADS)

    Villavicencio, A. L. C. H.; Araújo, M. M.; Baldasso, J. G.; Aquino, S.; Konietzny, U.; Greiner, R.

    2004-09-01

    Three soybean varieties were analyzed to evaluate the irradiation influence on the detection of genetic modification. Samples were treated in a 60Co facility at dose levels of 0, 500, 800, and 1000Gy. The seeds were at first analyzed by Comet Assay as a rapid screening irradiation detection method. Secondly, germination test was performed to detect the viability of irradiated soybeans. Finally, because of its high sensitivity, its specificity and rapidity the polimerase chain reaction was the method applied for genetic modified organism detection. The analysis of DNA by the single technique of microgel electrophoresis of single cells (DNA Comet Assay) showed that DNA damage increased with increasing radiation doses. No negative influence of irradiation on the genetic modification detection was found.

  1. Automatic Fabric Defect Detection with a Multi-Scale Convolutional Denoising Autoencoder Network Model.

    PubMed

    Mei, Shuang; Wang, Yudan; Wen, Guojun

    2018-04-02

    Fabric defect detection is a necessary and essential step of quality control in the textile manufacturing industry. Traditional fabric inspections are usually performed by manual visual methods, which are low in efficiency and poor in precision for long-term industrial applications. In this paper, we propose an unsupervised learning-based automated approach to detect and localize fabric defects without any manual intervention. This approach is used to reconstruct image patches with a convolutional denoising autoencoder network at multiple Gaussian pyramid levels and to synthesize detection results from the corresponding resolution channels. The reconstruction residual of each image patch is used as the indicator for direct pixel-wise prediction. By segmenting and synthesizing the reconstruction residual map at each resolution level, the final inspection result can be generated. This newly developed method has several prominent advantages for fabric defect detection. First, it can be trained with only a small amount of defect-free samples. This is especially important for situations in which collecting large amounts of defective samples is difficult and impracticable. Second, owing to the multi-modal integration strategy, it is relatively more robust and accurate compared to general inspection methods (the results at each resolution level can be viewed as a modality). Third, according to our results, it can address multiple types of textile fabrics, from simple to more complex. Experimental results demonstrate that the proposed model is robust and yields good overall performance with high precision and acceptable recall rates.

  2. New Possibilities of Substance Identification Based on THz Time Domain Spectroscopy Using a Cascade Mechanism of High Energy Level Excitation

    PubMed Central

    Trofimov, Vyacheslav A.; Varentsova, Svetlana A.; Zakharova, Irina G.; Zagursky, Dmitry Yu.

    2017-01-01

    Using an experiment with thin paper layers and computer simulation, we demonstrate the principal limitations of standard Time Domain Spectroscopy (TDS) based on using a broadband THz pulse for the detection and identification of a substance placed inside a disordered structure. We demonstrate the spectrum broadening of both transmitted and reflected pulses due to the cascade mechanism of the high energy level excitation considering, for example, a three-energy level medium. The pulse spectrum in the range of high frequencies remains undisturbed in the presence of a disordered structure. To avoid false absorption frequencies detection, we apply the spectral dynamics analysis method (SDA-method) together with certain integral correlation criteria (ICC). PMID:29186849

  3. Bio-barcode gel assay for microRNA

    NASA Astrophysics Data System (ADS)

    Lee, Hyojin; Park, Jeong-Eun; Nam, Jwa-Min

    2014-02-01

    MicroRNA has been identified as a potential biomarker because expression level of microRNA is correlated with various cancers. Its detection at low concentrations would be highly beneficial for cancer diagnosis. Here, we develop a new type of a DNA-modified gold nanoparticle-based bio-barcode assay that uses a conventional gel electrophoresis platform and potassium cyanide chemistry and show this assay can detect microRNA at aM levels without enzymatic amplification. It is also shown that single-base-mismatched microRNA can be differentiated from perfectly matched microRNA and the multiplexed detection of various combinations of microRNA sequences is possible with this approach. Finally, differently expressed microRNA levels are selectively detected from cancer cells using the bio-barcode gel assay, and the results are compared with conventional polymerase chain reaction-based results. The method and results shown herein pave the way for practical use of a conventional gel electrophoresis for detecting biomolecules of interest even at aM level without polymerase chain reaction amplification.

  4. Quantitative Method of Measuring Metastatic Activity

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R. (Inventor)

    1999-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated uroldnase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  5. Comparison of isthmus detection methods in the apical third of mesial roots of maxillary and mandibular first molars: macroscopic observation versus operating microscope.

    PubMed

    Kontakiotis, Evangelos G; Palamidakis, Fotios D; Farmakis, Eleftherios-Terry R; Tzanetakis, Giorgos N

    2010-01-01

    The aims of this study were to assess the presence and the frequency of isthmuses in the mesial roots of the maxillary and mandibular first molars (at two resection levels from the apex), and to compare the findings obtained by macroscopic observation (MO) and operating microscope (OM). Forty maxillary and 40 mandibular mesial roots were observed at 3 and 5 mm from the apex initially macroscopically and then with the use of an OM. The presence of an isthmus and the number of root canals detected were recorded. Data were analyzed statistically by Fisher's exact test for isthmus evaluation and Wilcoxon signed rank-test for number of root canals at a confidence interval of 95%. Comparison between MO and OM regarding the number of roots with isthmuses provided the following results: Mandibular group: At 3 mm level: MO 19 ?s. OM 27; at 5 mm level: MO 31 ?s. OM 32. Maxillary group: At 3 mm level: MO 9 ?s. OM 14; at 5 mm level: MO 19 ?s. OM 21. Significant differences (p<0.05) were found concerning the accuracy of the isthmus detection methods at both resection levels (3 and 5 mm) and both types of roots, as well as for the number of the canals inspected under the OM between the two resection levels of the mesial roots of the maxillary first molars. Under the tested conditions, OM increased the diagnostic accuracy of isthmus detection at both resection levels and root types.

  6. Relating to ion detection

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2001-01-01

    The apparatus and method provide a technique for improving detection of alpha and/or beta emitting sources on items or in locations using indirect means. The emission forms generate ions in a medium surrounding the item or location and the medium is then moved to a detecting location where the ions are discharged to give a measure of the emission levels. To increase the level of ions generated and render the system particularly applicable for narrow pipes and other forms of conduits, the medium pressure is increased above atmospheric pressure. STATEMENT REGARDING FEDERALLY SPONSORED RESEARCH OR DEVELOPMENT

  7. Rapid detection of Salmonella in pet food: design and evaluation of integrated methods based on real-time PCR detection.

    PubMed

    Balachandran, Priya; Friberg, Maria; Vanlandingham, V; Kozak, K; Manolis, Amanda; Brevnov, Maxim; Crowley, Erin; Bird, Patrick; Goins, David; Furtado, Manohar R; Petrauskene, Olga V; Tebbs, Robert S; Charbonneau, Duane

    2012-02-01

    Reducing the risk of Salmonella contamination in pet food is critical for both companion animals and humans, and its importance is reflected by the substantial increase in the demand for pathogen testing. Accurate and rapid detection of foodborne pathogens improves food safety, protects the public health, and benefits food producers by assuring product quality while facilitating product release in a timely manner. Traditional culture-based methods for Salmonella screening are laborious and can take 5 to 7 days to obtain definitive results. In this study, we developed two methods for the detection of low levels of Salmonella in pet food using real-time PCR: (i) detection of Salmonella in 25 g of dried pet food in less than 14 h with an automated magnetic bead-based nucleic acid extraction method and (ii) detection of Salmonella in 375 g of composite dry pet food matrix in less than 24 h with a manual centrifugation-based nucleic acid preparation method. Both methods included a preclarification step using a novel protocol that removes food matrix-associated debris and PCR inhibitors and improves the sensitivity of detection. Validation studies revealed no significant differences between the two real-time PCR methods and the standard U.S. Food and Drug Administration Bacteriological Analytical Manual (chapter 5) culture confirmation method.

  8. Airplane detection based on fusion framework by combining saliency model with Deep Convolutional Neural Networks

    NASA Astrophysics Data System (ADS)

    Dou, Hao; Sun, Xiao; Li, Bin; Deng, Qianqian; Yang, Xubo; Liu, Di; Tian, Jinwen

    2018-03-01

    Aircraft detection from very high resolution remote sensing images, has gained more increasing interest in recent years due to the successful civil and military applications. However, several problems still exist: 1) how to extract the high-level features of aircraft; 2) locating objects within such a large image is difficult and time consuming; 3) A common problem of multiple resolutions of satellite images still exists. In this paper, inspirited by biological visual mechanism, the fusion detection framework is proposed, which fusing the top-down visual mechanism (deep CNN model) and bottom-up visual mechanism (GBVS) to detect aircraft. Besides, we use multi-scale training method for deep CNN model to solve the problem of multiple resolutions. Experimental results demonstrate that our method can achieve a better detection result than the other methods.

  9. Development and validation of an immunochromatographic assay for rapid detection of fumonisin B1 from cereal samples.

    PubMed

    Venkataramana, M; Navya, K; Chandranayaka, S; Priyanka, S R; Murali, H S; Batra, H V

    2014-09-01

    Fumonisins are one of the most agriculturally significant environmental toxins produced by Fusarium and Aspergillus species that grow on agricultural commodities in the field or during storage. Cereals contaminated with fumonisins causes serious loss to agricultural produce leads to health problems in humans and other farm animals. In the present study, polyclonal hyperimmune sera was raised against FB1 in rabbits immunized with FB1-keyhole limpet haemocyanin (KLH). Purified antibodies were used to establish a sensitive gold nanoparticle based immunochromatographic strip (ICG) for detecting FB1 levels in cereal grains. Effective on-site detection of FB1 was achieved by developing a rapid and sensitive pAb based ICG strip. This strip had a detection limit of 5 ng mL(-1) for FB1 in cereal samples and it could be completed within 3 min. Close examination of 150 cereal samples by ICG strip method revealed that 77 were fumonisin-positive. Results obtained by the developed method was further validated with well standardized HPLC method and results of strip method was correlated well with those obtained by HPLC method. In conclusion, the developed method was a better alternative for onsite detection of FB1 in cereal samples intended for human consumption to reduce risk of humans and other farm animals. The high level of FB1 concentrations recorded in present study warrants the need to develop an awareness creation programme to the farmers of India for safe handling of cereal grains at the time of harvesting and storage of grains.

  10. Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes detection kit in combination with ShortPrep foodproof II Kit. Performance-Tested Method 070401.

    PubMed

    Junge, Benjamin; Berghof-Jäger, Kornelia

    2006-01-01

    A method was developed for the detection of L. monocytogenes in food based on real-time polymerase chain reaction (PCR). This advanced PCR method was designed to reduce the time needed to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the Roche/BIOTECON Diagnostics ShortPrep foodproof II Kit (formerly called Listeria ShortPrep Kit) designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is performed by using the Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes Detection Kit. This kit provides primers and hybridization probes for sequence-specific detection, convenient premixed reagents, and different controls for reliable interpretation of results. For repeatability studies, 20 different foods, covering the 15 food groups recommended from the AOAC Research Institute (AOAC RI) for L. monocytogenes detection were analyzed: raw meats, fresh produce/vegetables, processed meats, seafood, egg and egg products, dairy (cultured/noncultured), spices, dry foods, fruit/juices, uncooked pasta, nuts, confectionery, pet food, food dyes and colorings, and miscellaneous. From each food 20, samples were inoculated with a low level (1-10 colony-forming units (CFU)/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, 5 uninoculated samples were prepared from each food. The food samples were examined with the test kits and in correlation with the cultural methods according to U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) or U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook. After 48 h of incubation, the PCR method in all cases showed equal or better results than the reference cultural FDA/BAM or USDA/FSIS methods. Fifteen out of 20 tested food types gave exactly the same amount of positive samples for both methods in both inoculation levels. For 5 out of 20 foodstuffs, the PCR method resulted in more positives than the reference method after 48 h of incubation. Following AOAC RI definition, these were false positives because they were not confirmed by the reference method (false-positive rate for low inoculated foodstuffs: 5.4%; for high inoculated foodstuffs: 7.1%). Without calculating these unconfirmed positives, the PCR method showed equal sensitivity results compared to the alternative method. With the unconfirmed PCR-positives included into the calculations, the alternative PCR method showed a higher sensitivity than the microbiological methods (low inoculation level: 100 vs 98.0%; sensitivity rate: 1; high inoculation level: 99.7 vs 97.7%; sensitivity rate, 1). All in-house and independently tested uninoculated food samples were negative for L. monocytogenes. The ruggedness testing of both ShortPrep foodproof II Kit and Roche/BIOTECON LightCycler foodproof L. monocytogenes Detection Kit showed no noteworthy influences to any variation of the parameters component concentration, apparatus comparison, tester comparison, and sample volumes. In total, 102 L. monocytogenes isolates (cultures and pure DNA) were tested and detected for the inclusivity study, including all isolates claimed by the AOAC RI. The exclusivity study included 60 non-L. monocytogenes bacteria. None of the tested isolates gave a false-positive result; specificity was 100%. Three different lots were tested in the lot-to-lot study. All 3 lots gave equal results. The stability study was subdivided into 3 parts: long-term study, stress test, and freeze-defrost test. Three lots were tested in 4 time intervals within a period of 13 months. They all gave comparable results for all test intervals. For the stress test, LightCycler L. monocytogenes detection mixes were stored at different temperatures and tested at different time points during 1 month. Stable results were produced at all storage temperatures. The freeze-defrost analysis showed no noteworthy aggravation of test results. The independent validation study examined by Campden and Chorleywood Food Research Association Group (CCFRA) demonstrated again that the LightCycler L. monocytogenes detection system shows a comparable sensitivity to reference methods. With both the LightCycler PCR and BAM methods, 19 out of 20 inoculated food samples were detected. The 24 h PCR results generated by the LightCycler system corresponded directly with the FDA/BAM culture results. However, the 48 h PCR results did not relate exactly to the FDA/BAM results, as one sample found to be positive by the 48 h PCR could not be culturally confirmed and another sample which was negative by the 48 h PCR was culturally positive.

  11. Nanoporous Substrate with Mixed Nanoclusters for Surface Enhanced Raman Scattering.

    NASA Astrophysics Data System (ADS)

    Chang, Sehoon; Ko, Hyunhyub; Singamaneni, Srikanth; Gunawidjaja, Ray; Tsukruk, Vladimir

    2009-03-01

    Rapid detection of plastic and liquid explosives is an urgent need due to various societal and technological reasons. We employed a novel design of surface enhanced Raman scattering (SERS)-active substrate based on porous alumina membranes decorated with mixed nanoclusters of gold nanorods and nanoparticles. We demonstrated trace level detection of several important explosives such as dinitrotolene (DNT), trinitrotoluene (TNT), and hexamethylenetriperoxidediamine (HMTD) by fast, sensitive, reliable Raman spectroscopic method. We achieved near molecular-level detection (about 15˜ 30 molecules) of DNT and TNT utilizing the SERS substrate. However, trace level detection is challenging due to the lack of common optical signatures (fluorescence, absorption in UV-vis range) or chemical functionality of peroxide-based explosives such as HMTD. To overcome this, we employed photochemical decomposition approach and analyzed chemical fragments using SERS. We suggest that tailored polymer coating, mixed nanoclusters, and laser-induced photocatalytic decomposition are all critical for achieving this unprecedented sensitivity level..

  12. Invasive pulmonary aspergillosis: current diagnostic methodologies and a new molecular approach.

    PubMed

    Moura, S; Cerqueira, L; Almeida, A

    2018-05-13

    The fungus Aspergillus fumigatus is the main pathogenic agent responsible for invasive pulmonary aspergillosis. Immunocompromised patients are more likely to develop this pathology due to a decrease in the immune system's defense capacity. Despite of the low occurrence of invasive pulmonary aspergillosis, this pathology presents high rates of mortality, mostly due to late and unspecific diagnosis. Currently, the diagnostic methods used to detect this fungal infection are conventional mycological examination (direct microscopic examination, histological examination, and culture), imaging, non-culture-based tests for the detection of galactomannan, β(1,3)-glucan and an extracellular glycoprotein, and molecular tests based on PCR. However, most of these methods do not detect the species A. fumigatus; they only allow the identification of genus Aspergillus. The development of more specific detection methods is of extreme importance. Fluorescent in situ hybridization-based molecular methods can be a good alternative to achieve this purpose. In this review, it is intended to point out that most of the methods used for the diagnosis of invasive pulmonary aspergillosis do not allow to detect the fungus at the species level and that fluorescence in situ hybridization-based molecular method will be a promising approach in the A. fumigatus detection.

  13. Comparison of Bayesian clustering and edge detection methods for inferring boundaries in landscape genetics

    USGS Publications Warehouse

    Safner, T.; Miller, M.P.; McRae, B.H.; Fortin, M.-J.; Manel, S.

    2011-01-01

    Recently, techniques available for identifying clusters of individuals or boundaries between clusters using genetic data from natural populations have expanded rapidly. Consequently, there is a need to evaluate these different techniques. We used spatially-explicit simulation models to compare three spatial Bayesian clustering programs and two edge detection methods. Spatially-structured populations were simulated where a continuous population was subdivided by barriers. We evaluated the ability of each method to correctly identify boundary locations while varying: (i) time after divergence, (ii) strength of isolation by distance, (iii) level of genetic diversity, and (iv) amount of gene flow across barriers. To further evaluate the methods' effectiveness to detect genetic clusters in natural populations, we used previously published data on North American pumas and a European shrub. Our results show that with simulated and empirical data, the Bayesian spatial clustering algorithms outperformed direct edge detection methods. All methods incorrectly detected boundaries in the presence of strong patterns of isolation by distance. Based on this finding, we support the application of Bayesian spatial clustering algorithms for boundary detection in empirical datasets, with necessary tests for the influence of isolation by distance. ?? 2011 by the authors; licensee MDPI, Basel, Switzerland.

  14. Rationalizing and advancing the 3-MPBA SERS sandwich assay for rapid detection of bacteria in environmental and food matrices.

    PubMed

    Pearson, Brooke; Mills, Alexander; Tucker, Madeline; Gao, Siyue; McLandsborough, Lynne; He, Lili

    2018-06-01

    Bacterial foodborne illness continues to be a pressing issue in our food supply. Rapid detection methods are needed for perishable foods due to their short shelf lives and significant contribution to foodborne illness. Previously, a sensitive and reliable surface-enhanced Raman spectroscopy (SERS) sandwich assay based on 3-mercaptophenylboronic acid (3-MBPA) as a capturer and indicator molecule was developed for rapid bacteria detection. In this study, we explored the advantages and constraints of this assay over the conventional aerobic plate count (APC) method and further developed methods for detection in real environmental and food matrices. The SERS sandwich assay was able to detect environmental bacteria in pond water and on spinach leaves at higher levels than the APC method. In addition, the SERS assay appeared to have higher sensitivity to quantify bacteria in the stationary phase. On the other hand, the APC method was more sensitive to cell viability. Finally, a method to detect bacteria in a challenging high-sugar juice matrix was developed to enhance bacteria capture. This study advanced the SERS technique for real applications in environment and food matrices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Detection of adulterated honey produced by honeybee (Apis mellifera L.) colonies fed with different levels of commercial industrial sugar (C₃ and C₄ plants) syrups by the carbon isotope ratio analysis.

    PubMed

    Guler, Ahmet; Kocaokutgen, Hasan; Garipoglu, Ali V; Onder, Hasan; Ekinci, Deniz; Biyik, Selim

    2014-07-15

    In the present study, one hundred pure and adulterated honey samples obtained from feeding honeybee colonies with different levels (5, 20 and 100 L/colony) of various commercial sugar syrups including High Fructose Corn Syrup 85 (HFCS-85), High Fructose Corn Syrup 55 (HFCS-55), Bee Feeding Syrup (BFS), Glucose Monohydrate Sugar (GMS) and Sucrose Sugar (SS) were evaluated in terms of the δ(13)C value of honey and its protein, difference between the δ(13)C value of protein and honey (Δδ(13)C), and C4% sugar ratio. Sugar type, sugar level and the sugar type*sugar level interaction were found to be significant (P<0.001) regarding the evaluated characteristics. Adulterations could not be detected in the 5L/colony syrup level of all sugar types when the δ(13)C value of honey, Δδ(13)C (protein-honey), and C4% sugar ratio were used as criteria according to the AOAC standards. However, it was possible to detect the adulteration by using the same criteria in the honeys taken from the 20 and 100 L/colony of HFCS-85 and the 100L/colony of HFCS-55. Adulteration at low syrup level (20 L/colony) was more easily detected when the fructose content of HFCS syrup increased. As a result, the official methods (AOAC, 978.17, 1995; AOAC, 991.41, 1995; AOAC 998.12, 2005) and Internal Standard Carbon Isotope Ratio Analysis could not efficiently detect the indirect adulteration of honey obtained by feeding the bee colonies with the syrups produced from C3 plants such as sugar beet (Beta vulgaris) and wheat (Triticium vulgare). For this reason, it is strongly needed to develop novel methods and standards that can detect the presence and the level of indirect adulterations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Assessing blood brain barrier dynamics or identifying or measuring selected substances or toxins in a subject by analyzing Raman spectrum signals of selected regions in the eye

    NASA Technical Reports Server (NTRS)

    Lambert, James L. (Inventor); Borchert, Mark S. (Inventor)

    2003-01-01

    A non-invasive method for analyzing the blood-brain barrier includes obtaining a Raman spectrum of a selected portion of the eye and monitoring the Raman spectrum to ascertain a change to the dynamics of the blood brain barrier. Also, non-invasive methods for determining the brain or blood level of an analyte of interest, such as glucose, drugs, alcohol, poisons, and the like, comprises: generating an excitation laser beam (e.g., at a wavelength of 600 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor, vitreous humor, or one or more conjunctiva vessels in the eye is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated portion of the eye; and then determining the blood level or brain level (intracranial or cerebral spinal fluid level) of an analyte of interest for the subject from the Raman spectrum. In certain embodiments, the detecting step may be followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level and/or brain level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing methods are also disclosed.

  17. Assessing blood brain barrier dynamics or identifying or measuring selected substances, including ethanol or toxins, in a subject by analyzing Raman spectrum signals

    NASA Technical Reports Server (NTRS)

    Borchert, Mark S. (Inventor); Lambert, James L. (Inventor)

    2008-01-01

    A non-invasive method for analyzing the blood-brain barrier includes obtaining a Raman spectrum of a selected portion of the eye and monitoring the Raman spectrum to ascertain a change to the dynamics of the blood brain barrier.Also, non-invasive methods for determining the brain or blood level of an analyte of interest, such as glucose, drugs, alcohol, poisons, and the like, comprises: generating an excitation laser beam at a selected wavelength (e.g., at a wavelength of about 400 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor, vitreous humor, or one or more conjunctiva vessels in the eye is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated portion of the eye; and then determining the blood level or brain level (intracranial or cerebral spinal fluid level) of an analyte of interest for the subject from the Raman spectrum. In certain embodiments, the detecting step may be followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level and/or brain level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing methods are also disclosed.

  18. [Detection of recombinant-DNA in foods from stacked genetically modified plants].

    PubMed

    Sorokina, E Iu; Chernyshova, O N

    2012-01-01

    A quantitative real-time multiplex polymerase chain reaction method was applied to the detection and quantification of MON863 and MON810 in stacked genetically modified maize MON 810xMON 863. The limit of detection was approximately 0,1%. The accuracy of the quantification, measured as bias from the accepted value and the relative repeatability standard deviation, which measures the intra-laboratory variability, were within 25% at each GM-level. A method verification has demonstrated that the MON 863 and the MON810 methods can be equally applied in quantification of the respective events in stacked MON810xMON 863.

  19. Quantitative analysis of ginger components in commercial products using liquid chromatography with electrochemical array detection

    PubMed Central

    Shao, Xi; Lv, Lishuang; Parks, Tiffany; Wu, Hou; Ho, Chi-Tang; Sang, Shengmin

    2010-01-01

    For the first time, a sensitive reversed-phase HPLC electrochemical array method has been developed for the quantitative analysis of eight major ginger components ([6]-, [8]-, and [10]-gingerol, [6]-, [8]-, and [10]-shogaol, [6]-paradol, and [1]-dehydrogingerdione) in eleven ginger-containing commercial products. This method was valid with unrivaled sensitivity as low as 7.3 – 20.2 pg of limit of detection and a range of 14.5 to 40.4 pg of limit of quantification. Using this method, we quantified the levels of eight ginger components in eleven different commercial products. Our results found that both levels and ratios among the eight compounds vary greatly in commercial products. PMID:21090746

  20. Comparison of supercritical fluid extraction and Soxhlet extraction for the determination of PCBs in seaweed samples.

    PubMed

    Punín Crespo, M O; Lage Yusty, M A

    2005-06-01

    The efficiency of supercritical fluid extraction for the determination of 12 polychlorinated biphenyls from algae samples is compared to Soxhlet extraction. Analytical detection limits for the individual congeners ranged from 0.62 microgl(-1) to 19 microgl(-1). Recovery was tested for both methods using standard addition procedure. At maximum spike level of concentration, the mean recoveries were not significantly different (P>0.05) of all PCBs studied, with the exception of PCBs 28, 52, 77 and 169. Method precision for Soxhlet extraction (< or =3.9%) was slightly better than for SFE (< or =9.2%). Although both methods yield comparable results, SFE offers the advantage of detecting all PCBs studied at lower concentrations, reducing extraction time, and reducing the amount of solvents needed. The optimized methods were applied to the analysis of three real seaweed samples, except for PCB101 the concentrations of all PCBs were low or below the detection limits. The levels of PCB101 found in sample 1 were 6.6+/-0.54 ng g(-1) d.w., in sample 2 the levels were 8.2+/-0.86 ng g(-1) d.w. and in sample 3 they were 7.7+/-0.08 ng g(-1) d.w.

  1. Unsupervised change detection of multispectral images based on spatial constraint chi-squared transform and Markov random field model

    NASA Astrophysics Data System (ADS)

    Shi, Aiye; Wang, Chao; Shen, Shaohong; Huang, Fengchen; Ma, Zhenli

    2016-10-01

    Chi-squared transform (CST), as a statistical method, can describe the difference degree between vectors. The CST-based methods operate directly on information stored in the difference image and are simple and effective methods for detecting changes in remotely sensed images that have been registered and aligned. However, the technique does not take spatial information into consideration, which leads to much noise in the result of change detection. An improved unsupervised change detection method is proposed based on spatial constraint CST (SCCST) in combination with a Markov random field (MRF) model. First, the mean and variance matrix of the difference image of bitemporal images are estimated by an iterative trimming method. In each iteration, spatial information is injected to reduce scattered changed points (also known as "salt and pepper" noise). To determine the key parameter confidence level in the SCCST method, a pseudotraining dataset is constructed to estimate the optimal value. Then, the result of SCCST, as an initial solution of change detection, is further improved by the MRF model. The experiments on simulated and real multitemporal and multispectral images indicate that the proposed method performs well in comprehensive indices compared with other methods.

  2. Analysis of haloacetic acids, bromate, and dalapon in natural waters by ion chromatography-tandem mass spectrometry.

    PubMed

    Wu, Shimin; Anumol, Tarun; Gandhi, Jay; Snyder, Shane A

    2017-03-03

    The addition of oxidants for disinfecting water can lead to the formation of potentially carcinogenic compounds referred to as disinfection byproducts (DBPs). Haloacetic acids (HAAs) are one of the most widely detected DBPs in US water utilities and some of them are regulated by the US Environmental Protection Agency (USEPA). The present study developed a method to analyze all the compounds in the USEPA method 557 (nine HAAs, bromate and dalapon) plus four potentially more toxic iodinated HAAs in water by coupling ion chromatography with tandem mass spectrometry (IC-MS/MS). This aqueous direct injection method has significant advantages over traditional GC methods, which require a derivatization and sample extraction that are laborious, time-consuming, and can negatively impact reproducibility. The method developed in this study requires half the time of the current USEPA method 557 on IC-MS/MS while including more compounds and achieving sub-μg/L level method detection limits (MDLs) for all 15 target analytes. The single laboratory lowest concentration minimum reporting level (LCMRL) has also been determined in reagent water, which ranged from 0.011 to 0.62μg/L for the analytes. The mean recoveries of the analytes during matrix spike recovery tests were 77-125% in finished drinking water and 81-112% in surface water. This method was then applied to untreated, chlorinated, and chloraminated groundwater and surface water samples. Bromate and 9 HAAs were detected at different levels in some of these samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Predictors of Detection of Alcohol Use Episodes Using a Transdermal Alcohol Sensor

    PubMed Central

    Barnett, Nancy P.; Meade, E.B.; Glynn, Tiffany R.

    2014-01-01

    The objective of this investigation was to establish the ability of the Secure Continuous Remote Alcohol Monitoring (SCRAM) alcohol sensor to detect different levels of self-reported alcohol consumption, and to determine whether gender and body mass index, alcohol dependence, bracelet version, and age of bracelet influenced detection of alcohol use. Method Heavy drinking adults (N = 66; 46% female) wore the SCRAM for 1–28 days and reported their alcohol use in daily web-based surveys. Participant reports of alcohol use were matched with drinking episodes identified from bracelet readings. Results On days when bracelets were functional, 690 drinking episodes were reported and 502 of those episodes (72.8%) were detected using sensor data. Using Generalized Estimating Equations, we found no gender differences in detection of reported drinking episodes (77% for women, 69% for men). In univariate analyses, at the level of fewer than five drinks, women’s episodes were more likely to be detected, likely due to the significantly higher TAC levels of these episodes, whereas at the level of five or more drinks, there was no gender difference in detection (92.6% for women, 93.4% of men’s). In multivariable analyses, no variables other than number of drinks significantly predicted alcohol detection. Conclusion The SCRAM sensor is very good at detecting five or more drinks; performance of the monitor below this level was better among women due to their higher TAC levels. Individual person characteristics and bracelet features were not related to detection after number of drinks was included. Minimal bracelet malfunctions were noted. PMID:24490713

  4. A Metric for Reducing False Positives in the Computer-Aided Detection of Breast Cancer from Dynamic Contrast-Enhanced Magnetic Resonance Imaging Based Screening Examinations of High-Risk Women.

    PubMed

    Levman, Jacob E D; Gallego-Ortiz, Cristina; Warner, Ellen; Causer, Petrina; Martel, Anne L

    2016-02-01

    Magnetic resonance imaging (MRI)-enabled cancer screening has been shown to be a highly sensitive method for the early detection of breast cancer. Computer-aided detection systems have the potential to improve the screening process by standardizing radiologists to a high level of diagnostic accuracy. This retrospective study was approved by the institutional review board of Sunnybrook Health Sciences Centre. This study compares the performance of a proposed method for computer-aided detection (based on the second-order spatial derivative of the relative signal intensity) with the signal enhancement ratio (SER) on MRI-based breast screening examinations. Comparison is performed using receiver operating characteristic (ROC) curve analysis as well as free-response receiver operating characteristic (FROC) curve analysis. A modified computer-aided detection system combining the proposed approach with the SER method is also presented. The proposed method provides improvements in the rates of false positive markings over the SER method in the detection of breast cancer (as assessed by FROC analysis). The modified computer-aided detection system that incorporates both the proposed method and the SER method yields ROC results equal to that produced by SER while simultaneously providing improvements over the SER method in terms of false positives per noncancerous exam. The proposed method for identifying malignancies outperforms the SER method in terms of false positives on a challenging dataset containing many small lesions and may play a useful role in breast cancer screening by MRI as part of a computer-aided detection system.

  5. An Unsupervised Change Detection Method Using Time-Series of PolSAR Images from Radarsat-2 and GaoFen-3.

    PubMed

    Liu, Wensong; Yang, Jie; Zhao, Jinqi; Shi, Hongtao; Yang, Le

    2018-02-12

    The traditional unsupervised change detection methods based on the pixel level can only detect the changes between two different times with same sensor, and the results are easily affected by speckle noise. In this paper, a novel method is proposed to detect change based on time-series data from different sensors. Firstly, the overall difference image of the time-series PolSAR is calculated by omnibus test statistics, and difference images between any two images in different times are acquired by R j test statistics. Secondly, the difference images are segmented with a Generalized Statistical Region Merging (GSRM) algorithm which can suppress the effect of speckle noise. Generalized Gaussian Mixture Model (GGMM) is then used to obtain the time-series change detection maps in the final step of the proposed method. To verify the effectiveness of the proposed method, we carried out the experiment of change detection using time-series PolSAR images acquired by Radarsat-2 and Gaofen-3 over the city of Wuhan, in China. Results show that the proposed method can not only detect the time-series change from different sensors, but it can also better suppress the influence of speckle noise and improve the overall accuracy and Kappa coefficient.

  6. Assessment of soil-gas, soil, and water contamination at the former 19th Street landfill, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Falls, W. Fred; Caldwell, Andral W.; Guimaraes, Wladmir B.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    Soil gas, soil, and water were assessed for organic and inorganic constituents at the former 19th Street landfill at Fort Gordon, Georgia, from February to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone and flood plain of a creek and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The passive soil-gas samplers deployed in the water-saturated hyporheic zone and flood plain of the creek adjacent to the former landfill indicated the presence of total petroleum hydrocarbon (TPH) and octane above method detection levels in groundwater beneath the creek bed and flood plain at all 12 soil-gas sampler locations. The TPH concentrations ranged from 51.4 to 81.4 micrograms per liter. Octane concentrations ranged from 1.78 to 2.63 micrograms per liter. These detections do not clearly identify specific source areas in the former landfill; moreover, detections of TPH and octane in a soil-gas sampler installed at a seep on the western bank of the creek indicated the potential for these constituents to be derived from source areas outside the estimated boundaries of the former landfill. A passive soil-gas sampler survey was conducted in the former landfill from June 30 to July 5, 2010, and involved 56 soil-gas samplers that were analyzed for petroleum and halogenated compounds not classified as chemical agents or explosives. The TPH soil-gas mass exceeded 2.0 micrograms in 21 samplers. Most noticeable are the two sites with TPH detections which are located in and near the hyporheic zone and are likely to affect the creek. However, most TPH detections were located in and immediately adjacent to a debris field located within the former landfill and in areas where debris was not visible, including the northwestern and southeastern parts of the study area. Two of the four soil-gas samplers installed within a former military training area adjacent to the landfill also had TPH detections above the method detection level. Benzene, toluene, ethylbenzene, and xylene (as combined BTEX mass) were detected at 0.02 microgram or greater in three soil-gas samplers installed at the northwestern boundary and in five samplers installed in the southeastern part of the study area. There was no BTEX mass detected above the method detection level in samplers installed in the debris field. Toluene was the most frequently detected BTEX compound. Compounds indicative of diesel-range organics were detected above 0.04 microgram in 12 soil-gas samplers and had a distribution similar to that of TPH, including being detected in the debris field. Undecane was the most frequently detected diesel compound. Chloroform and naphthalene were detected in eight and two soil-gas samplers, respectively. Five soil-gas samplers deployed during September 2010 were analyzed for organic compounds classified as chemical agents and explosives, but none exceeded the method detection levels. Five composite soil samples collected from within the estimated boundaries of the former landfill were analyzed for 35 inorganic constituents, but none of the constituents detected exceeded regional screening levels for industrial soils. The sample collected in the debris field exceeded background levels for aluminum, barium, calcium, chromium, lead, nickel, potassium, sodium, and zinc. Three surface-water samples were collected in September 2010 from a stormwater outfall culvert that drains to the creek and from the open channel of the creek at upstream and downstream locations relative to the outfall. Toluene was detected at 0.661 mi

  7. Evaluation of the VIDAS Listeria (LIS) immunoassay for the detection of Listeria in foods using demi-Fraser and Fraser enrichment broths, as modification of AOAC Official Method 999.06 (AOAC Official Method 2004.06).

    PubMed

    Silbernagel, Karen M; Jechorek, Robert P; Kaufer, Amanda L; Johnson, Ronald L; Aleo, V; Brown, B; Buen, M; Buresh, J; Carson, M; Franklin, J; Ham, P; Humes, L; Husby, G; Hutchins, J; Jechorek, R; Jenkins, J; Kaufer, A; Kexel, N; Kora, L; Lam, L; Lau, D; Leighton, S; Loftis, M; Luc, S; Martin, J; Nacar, I; Nogle, J; Park, J; Schultz, A; Seymore, D; Smith, C; Smith, J; Thou, P; Ulmer, M; Voss, R; Weaver, V

    2005-01-01

    A multilaboratory study was conducted to compare the VIDAS LIS immunoassay with the standard cultural methods for the detection of Listeria in foods using an enrichment modification of AOAC Official Method 999.06. The modified enrichment protocol was implemented to harmonize the VIDAS LIS assay with the VIDAS LMO2 assay. Five food types--brie cheese, vanilla ice cream, frozen green beans, frozen raw tilapia fish, and cooked roast beef--at 3 inoculation levels, were analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study, 1206 test portions were tested, of which 1170 were used in the statistical analysis. There were 433 positive by the VIDAS LIS assay and 396 positive by the standard culture methods. A Chi-square analysis of each of the 5 food types, at the 3 inoculation levels tested, was performed. The resulting average Chi square analysis, 0.42, indicated that, overall, there are no statistical differences between the VIDAS LIS assay and the standard methods at the 5% level of significance.

  8. Detection of bone disease by hybrid SST-watershed x-ray image segmentation

    NASA Astrophysics Data System (ADS)

    Sanei, Saeid; Azron, Mohammad; Heng, Ong Sim

    2001-07-01

    Detection of diagnostic features from X-ray images is favorable due to the low cost of these images. Accurate detection of the bone metastasis region greatly assists physicians to monitor the treatment and to remove the cancerous tissue by surgery. A hybrid SST-watershed algorithm, here, efficiently detects the boundary of the diseased regions. Shortest Spanning Tree (SST), based on graph theory, is one of the most powerful tools in grey level image segmentation. The method converts the images into arbitrary-shape closed segments of distinct grey levels. To do that, the image is initially mapped to a tree. Then using RSST algorithm the image is segmented to a certain number of arbitrary-shaped regions. However, in fine segmentation, over-segmentation causes loss of objects of interest. In coarse segmentation, on the other hand, SST-based method suffers from merging the regions belonged to different objects. By applying watershed algorithm, the large segments are divided into the smaller regions based on the number of catchment's basins for each segment. The process exploits bi-level watershed concept to separate each multi-lobe region into a number of areas each corresponding to an object (in our case a cancerous region of the bone,) disregarding their homogeneity in grey level.

  9. Automated detection of heuristics and biases among pathologists in a computer-based system.

    PubMed

    Crowley, Rebecca S; Legowski, Elizabeth; Medvedeva, Olga; Reitmeyer, Kayse; Tseytlin, Eugene; Castine, Melissa; Jukic, Drazen; Mello-Thoms, Claudia

    2013-08-01

    The purpose of this study is threefold: (1) to develop an automated, computer-based method to detect heuristics and biases as pathologists examine virtual slide cases, (2) to measure the frequency and distribution of heuristics and errors across three levels of training, and (3) to examine relationships of heuristics to biases, and biases to diagnostic errors. The authors conducted the study using a computer-based system to view and diagnose virtual slide cases. The software recorded participant responses throughout the diagnostic process, and automatically classified participant actions based on definitions of eight common heuristics and/or biases. The authors measured frequency of heuristic use and bias across three levels of training. Biases studied were detected at varying frequencies, with availability and search satisficing observed most frequently. There were few significant differences by level of training. For representativeness and anchoring, the heuristic was used appropriately as often or more often than it was used in biased judgment. Approximately half of the diagnostic errors were associated with one or more biases. We conclude that heuristic use and biases were observed among physicians at all levels of training using the virtual slide system, although their frequencies varied. The system can be employed to detect heuristic use and to test methods for decreasing diagnostic errors resulting from cognitive biases.

  10. Change detection of polarimetric SAR images based on the KummerU Distribution

    NASA Astrophysics Data System (ADS)

    Chen, Quan; Zou, Pengfei; Li, Zhen; Zhang, Ping

    2014-11-01

    In the society of PolSAR image segmentation, change detection and classification, the classical Wishart distribution has been used for a long time, but it especially suit to low-resolution SAR image, because in traditional sensors, only a small number of scatterers are present in each resolution cell. With the improving of SAR systems these years, the classical statistical models can therefore be reconsidered for high resolution and polarimetric information contained in the images acquired by these advanced systems. In this study, SAR image segmentation algorithm based on level-set method, added with distance regularized level-set evolution (DRLSE) is performed using Envisat/ASAR single-polarization data and Radarsat-2 polarimetric images, respectively. KummerU heterogeneous clutter model is used in the later to overcome the homogeneous hypothesis at high resolution cell. An enhanced distance regularized level-set evolution (DRLSE-E) is also applied in the later, to ensure accurate computation and stable level-set evolution. Finally, change detection based on four polarimetric Radarsat-2 time series images is carried out at Genhe area of Inner Mongolia Autonomous Region, NorthEastern of China, where a heavy flood disaster occurred during the summer of 2013, result shows the recommend segmentation method can detect the change of watershed effectively.

  11. An Adaptive Multi-Sensor Data Fusion Method Based on Deep Convolutional Neural Networks for Fault Diagnosis of Planetary Gearbox

    PubMed Central

    Jing, Luyang; Wang, Taiyong; Zhao, Ming; Wang, Peng

    2017-01-01

    A fault diagnosis approach based on multi-sensor data fusion is a promising tool to deal with complicated damage detection problems of mechanical systems. Nevertheless, this approach suffers from two challenges, which are (1) the feature extraction from various types of sensory data and (2) the selection of a suitable fusion level. It is usually difficult to choose an optimal feature or fusion level for a specific fault diagnosis task, and extensive domain expertise and human labor are also highly required during these selections. To address these two challenges, we propose an adaptive multi-sensor data fusion method based on deep convolutional neural networks (DCNN) for fault diagnosis. The proposed method can learn features from raw data and optimize a combination of different fusion levels adaptively to satisfy the requirements of any fault diagnosis task. The proposed method is tested through a planetary gearbox test rig. Handcraft features, manual-selected fusion levels, single sensory data, and two traditional intelligent models, back-propagation neural networks (BPNN) and a support vector machine (SVM), are used as comparisons in the experiment. The results demonstrate that the proposed method is able to detect the conditions of the planetary gearbox effectively with the best diagnosis accuracy among all comparative methods in the experiment. PMID:28230767

  12. a Cloud Boundary Detection Scheme Combined with Aslic and Cnn Using ZY-3, GF-1/2 Satellite Imagery

    NASA Astrophysics Data System (ADS)

    Guo, Z.; Li, C.; Wang, Z.; Kwok, E.; Wei, X.

    2018-04-01

    Remote sensing optical image cloud detection is one of the most important problems in remote sensing data processing. Aiming at the information loss caused by cloud cover, a cloud detection method based on convolution neural network (CNN) is presented in this paper. Firstly, a deep CNN network is used to extract the multi-level feature generation model of cloud from the training samples. Secondly, the adaptive simple linear iterative clustering (ASLIC) method is used to divide the detected images into superpixels. Finally, the probability of each superpixel belonging to the cloud region is predicted by the trained network model, thereby generating a cloud probability map. The typical region of GF-1/2 and ZY-3 were selected to carry out the cloud detection test, and compared with the traditional SLIC method. The experiment results show that the average accuracy of cloud detection is increased by more than 5 %, and it can detected thin-thick cloud and the whole cloud boundary well on different imaging platforms.

  13. Use of CHAID Decision Trees to Formulate Pathways for the Early Detection of Metabolic Syndrome in Young Adults

    PubMed Central

    Liu, Pei-Yang

    2014-01-01

    Metabolic syndrome (MetS) in young adults (age 20–39) is often undiagnosed. A simple screening tool using a surrogate measure might be invaluable in the early detection of MetS. Methods. A chi-squared automatic interaction detection (CHAID) decision tree analysis with waist circumference user-specified as the first level was used to detect MetS in young adults using data from the National Health and Nutrition Examination Survey (NHANES) 2009-2010 Cohort as a representative sample of the United States population (n = 745). Results. Twenty percent of the sample met the National Cholesterol Education Program Adult Treatment Panel III (NCEP) classification criteria for MetS. The user-specified CHAID model was compared to both CHAID model with no user-specified first level and logistic regression based model. This analysis identified waist circumference as a strong predictor in the MetS diagnosis. The accuracy of the final model with waist circumference user-specified as the first level was 92.3% with its ability to detect MetS at 71.8% which outperformed comparison models. Conclusions. Preliminary findings suggest that young adults at risk for MetS could be identified for further followup based on their waist circumference. Decision tree methods show promise for the development of a preliminary detection algorithm for MetS. PMID:24817904

  14. Robust Ground Target Detection by SAR and IR Sensor Fusion Using Adaboost-Based Feature Selection

    PubMed Central

    Kim, Sungho; Song, Woo-Jin; Kim, So-Hyun

    2016-01-01

    Long-range ground targets are difficult to detect in a noisy cluttered environment using either synthetic aperture radar (SAR) images or infrared (IR) images. SAR-based detectors can provide a high detection rate with a high false alarm rate to background scatter noise. IR-based approaches can detect hot targets but are affected strongly by the weather conditions. This paper proposes a novel target detection method by decision-level SAR and IR fusion using an Adaboost-based machine learning scheme to achieve a high detection rate and low false alarm rate. The proposed method consists of individual detection, registration, and fusion architecture. This paper presents a single framework of a SAR and IR target detection method using modified Boolean map visual theory (modBMVT) and feature-selection based fusion. Previous methods applied different algorithms to detect SAR and IR targets because of the different physical image characteristics. One method that is optimized for IR target detection produces unsuccessful results in SAR target detection. This study examined the image characteristics and proposed a unified SAR and IR target detection method by inserting a median local average filter (MLAF, pre-filter) and an asymmetric morphological closing filter (AMCF, post-filter) into the BMVT. The original BMVT was optimized to detect small infrared targets. The proposed modBMVT can remove the thermal and scatter noise by the MLAF and detect extended targets by attaching the AMCF after the BMVT. Heterogeneous SAR and IR images were registered automatically using the proposed RANdom SAmple Region Consensus (RANSARC)-based homography optimization after a brute-force correspondence search using the detected target centers and regions. The final targets were detected by feature-selection based sensor fusion using Adaboost. The proposed method showed good SAR and IR target detection performance through feature selection-based decision fusion on a synthetic database generated by OKTAL-SE. PMID:27447635

  15. Robust Ground Target Detection by SAR and IR Sensor Fusion Using Adaboost-Based Feature Selection.

    PubMed

    Kim, Sungho; Song, Woo-Jin; Kim, So-Hyun

    2016-07-19

    Long-range ground targets are difficult to detect in a noisy cluttered environment using either synthetic aperture radar (SAR) images or infrared (IR) images. SAR-based detectors can provide a high detection rate with a high false alarm rate to background scatter noise. IR-based approaches can detect hot targets but are affected strongly by the weather conditions. This paper proposes a novel target detection method by decision-level SAR and IR fusion using an Adaboost-based machine learning scheme to achieve a high detection rate and low false alarm rate. The proposed method consists of individual detection, registration, and fusion architecture. This paper presents a single framework of a SAR and IR target detection method using modified Boolean map visual theory (modBMVT) and feature-selection based fusion. Previous methods applied different algorithms to detect SAR and IR targets because of the different physical image characteristics. One method that is optimized for IR target detection produces unsuccessful results in SAR target detection. This study examined the image characteristics and proposed a unified SAR and IR target detection method by inserting a median local average filter (MLAF, pre-filter) and an asymmetric morphological closing filter (AMCF, post-filter) into the BMVT. The original BMVT was optimized to detect small infrared targets. The proposed modBMVT can remove the thermal and scatter noise by the MLAF and detect extended targets by attaching the AMCF after the BMVT. Heterogeneous SAR and IR images were registered automatically using the proposed RANdom SAmple Region Consensus (RANSARC)-based homography optimization after a brute-force correspondence search using the detected target centers and regions. The final targets were detected by feature-selection based sensor fusion using Adaboost. The proposed method showed good SAR and IR target detection performance through feature selection-based decision fusion on a synthetic database generated by OKTAL-SE.

  16. Polarimetric Analysis of the Long Duration Gamma-Ray Burst GRB 160530A With the Balloon Borne Compton Spectrometer and Imager

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowell, A. W.; Boggs, S. E; Chiu, C. L.

    2017-10-20

    A long duration gamma-ray burst, GRB 160530A, was detected by the Compton Spectrometer and Imager (COSI) during the 2016 COSI Super Pressure Balloon campaign. As a Compton telescope, COSI is inherently sensitive to the polarization of gamma-ray sources in the energy range 0.2–5.0 MeV. We measured the polarization of GRB 160530A using (1) a standard method (SM) based on fitting the distribution of azimuthal scattering angles with a modulation curve and (2) an unbinned, maximum likelihood method (MLM). In both cases, the measured polarization level was below the 99% confidence minimum detectable polarization levels of 72.3% ± 0.8% (SM) andmore » 57.5% ± 0.8% (MLM). Therefore, COSI did not detect polarized gamma-ray emission from this burst. Our most constraining 90% confidence upper limit on the polarization level was 46% (MLM).« less

  17. Automatic Detection of Driver Fatigue Using Driving Operation Information for Transportation Safety

    PubMed Central

    Li, Zuojin; Chen, Liukui; Peng, Jun; Wu, Ying

    2017-01-01

    Fatigued driving is a major cause of road accidents. For this reason, the method in this paper is based on the steering wheel angles (SWA) and yaw angles (YA) information under real driving conditions to detect drivers’ fatigue levels. It analyzes the operation features of SWA and YA under different fatigue statuses, then calculates the approximate entropy (ApEn) features of a short sliding window on time series. Using the nonlinear feature construction theory of dynamic time series, with the fatigue features as input, designs a “2-6-6-3” multi-level back propagation (BP) Neural Networks classifier to realize the fatigue detection. An approximately 15-h experiment is carried out on a real road, and the data retrieved are segmented and labeled with three fatigue levels after expert evaluation, namely “awake”, “drowsy” and “very drowsy”. The average accuracy of 88.02% in fatigue identification was achieved in the experiment, endorsing the value of the proposed method for engineering applications. PMID:28587072

  18. Automatic Detection of Driver Fatigue Using Driving Operation Information for Transportation Safety.

    PubMed

    Li, Zuojin; Chen, Liukui; Peng, Jun; Wu, Ying

    2017-05-25

    Fatigued driving is a major cause of road accidents. For this reason, the method in this paper is based on the steering wheel angles (SWA) and yaw angles (YA) information under real driving conditions to detect drivers' fatigue levels. It analyzes the operation features of SWA and YA under different fatigue statuses, then calculates the approximate entropy (ApEn) features of a short sliding window on time series. Using the nonlinear feature construction theory of dynamic time series, with the fatigue features as input, designs a "2-6-6-3" multi-level back propagation (BP) Neural Networks classifier to realize the fatigue detection. An approximately 15-h experiment is carried out on a real road, and the data retrieved are segmented and labeled with three fatigue levels after expert evaluation, namely "awake", "drowsy" and "very drowsy". The average accuracy of 88.02% in fatigue identification was achieved in the experiment, endorsing the value of the proposed method for engineering applications.

  19. Efficacy of a chairside diagnostic test kit for estimation of C-reactive protein levels in periodontal disease

    PubMed Central

    Nagarale, Girish; Ravindra, S.; Thakur, Srinath; Setty, Swati

    2010-01-01

    Background: C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. Aim: The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. Materials and Methods: A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. Results: CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Conclusion: Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis. PMID:21731244

  20. [Arginase Level in Suspended Red Blood Cells Storaged for Different Time].

    PubMed

    Fan, Li-Ping; Huang, Hao-Bo; Wei, Shi-Jin; Fu, Dan-Hui; Zeng, Feng; Huang, Qing-Hua; Hong, Jin-Quan

    2015-10-01

    To explore the effect of storage time on arginase level, and the possible source of arginase in suspended red blood cells (RBC). The arginase and myeloperoxidase (MPO) levels in suspended RBC and control plasma were detected by ELISA. The free hemoglobin level in suspended RBC and control plasma were detected by colorimetric method. The relationship between arginase level, MPO level and free hemoglobin level in suspended RBC was analyzed by the related methods. The arginase and free hemoglobin levels in suspended RBC were higher than those in control plasma. Otherwise, MPO level was not significantly different between suspended RBC and control plasma. All of them did not increase along with prolonging of storage time. There was not a significant correlation between arginase level and free hemoglobin level in suspended RBC of different storage time (r = 0.03), but arginase level positively correlated with MPO level in the suspended RBC of different storage time (r = 0.76). The arginase level in suspended RBC storaged for different time increases significantly, but not along with prolonging of storage time. The main possible source of arginase in the suspended RBC is the residual white blood cell, especially neutrophils.

  1. A Simple and Efficient Method of Extracting DNA from Aged Bones and Teeth.

    PubMed

    Liu, Qiqi; Liu, Liyan; Zhang, Minli; Zhang, Qingzhen; Wang, Qiong; Ding, Xiaoran; Shao, Liting; Zhou, Zhe; Wang, Shengqi

    2018-05-01

    DNA is often difficult to extract from old bones and teeth due to low levels of DNA and high levels of degradation. This study established a simple yet efficient method for extracting DNA from 20 aged bones and teeth (approximately 60 years old). Based on the concentration and STR typing results, the new method of DNA extraction (OM) developed in this study was compared with the PrepFiler™ BTA Forensic DNA Extraction Kit (BM). The total amount of DNA extracted using the OM method was not significantly different from that extracted using the commercial kit (p > 0.05). However, the number of STR loci detected was significantly higher in the samples processed using the OM method than using the BM method (p < 0.05). This study aimed to establish a DNA extraction method for aged bones and teeth to improve the detection rate of STR typing and reduce costs compared to the BM technique. © 2017 American Academy of Forensic Sciences.

  2. Salient object detection based on multi-scale contrast.

    PubMed

    Wang, Hai; Dai, Lei; Cai, Yingfeng; Sun, Xiaoqiang; Chen, Long

    2018-05-01

    Due to the development of deep learning networks, a salient object detection based on deep learning networks, which are used to extract the features, has made a great breakthrough compared to the traditional methods. At present, the salient object detection mainly relies on very deep convolutional network, which is used to extract the features. In deep learning networks, an dramatic increase of network depth may cause more training errors instead. In this paper, we use the residual network to increase network depth and to mitigate the errors caused by depth increase simultaneously. Inspired by image simplification, we use color and texture features to obtain simplified image with multiple scales by means of region assimilation on the basis of super-pixels in order to reduce the complexity of images and to improve the accuracy of salient target detection. We refine the feature on pixel level by the multi-scale feature correction method to avoid the feature error when the image is simplified at the above-mentioned region level. The final full connection layer not only integrates features of multi-scale and multi-level but also works as classifier of salient targets. The experimental results show that proposed model achieves better results than other salient object detection models based on original deep learning networks. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Comparative Evaluation of Veriflow® Listeria monocytogenes to USDA and AOAC Culture Based Methods for the Detection of Listeria monocytogenes in Food.

    PubMed

    Joelsson, Adam C; Brown, Ashley S; Puri, Amrita; Keough, Martin P; Gaudioso, Zara E; Siciliano, Nicholas A; Snook, Adam E

    2015-01-01

    Veriflow® Listeria monocytogenes (LM) is a molecular based assay for the presumptive detection of Listeria monocytogenes from environmental surfaces, dairy, and ready-to-eat (RTE) food matrixes (hot dogs and deli meat). The assay utilizes a PCR detection method coupled with a rapid, visual, flow-based assay that develops in 3 min post PCR amplification and requires only 24 h of enrichment for maximum sensitivity. The Veriflow LM system eliminates the need for sample purification, gel electrophoresis, or fluorophore-based detection of target amplification, and does not require complex data analysis. This Performance Tested Method(SM) validation study demonstrated the ability of the Veriflow LM method to detect low levels of artificially inoculated L. monocytogenes in seven distinct environmental and food matrixes. In each unpaired reference comparison study, probability of detection analysis indicated no significant difference between the Veriflow LM method and the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook 8.08 or AOAC 993.12 reference method. Fifty strains of L. monocytogenes were detected in the inclusivity study, while 39 nonspecific organisms were undetected in the exclusivity study. The study results show that Veriflow LM is a sensitive, selective, and robust assay for the presumptive detection of L. monocytogenes sampled from environmental, dairy, or RTE (hot dogs and deli meat) food matrixes.

  4. Tunable generation and adsorption of energetic compounds in the vapor phase at trace levels: a tool for testing and developing sensitive and selective substrates for explosive detection.

    PubMed

    Bonnot, Karine; Bernhardt, Pierre; Hassler, Dominique; Baras, Christian; Comet, Marc; Keller, Valérie; Spitzer, Denis

    2010-04-15

    Among various methods for landmine detection, as well as soil and water pollution monitoring, the detection of explosive compounds in air is becoming an important and inevitable challenge for homeland security applications, due to the threatening increase in terrorist explosive bombs used against civil populations. However, in the last case, there is a crucial need for the detection of vapor phase traces or subtraces (in the ppt range or even lower). A novel and innovative generator for explosive trace vapors was designed and developed. It allowed the generation of theoretical concentrations as low as 0.24 ppq for hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in air according to Clapeyron equations. The accurate generation of explosive concentrations at subppt levels was verified for RDX and 2,4,6-trinitrotoluene (TNT) using a gas chromatograph coupled to an electron capture detector (GC-ECD). First, sensing material experiments were conducted on a nanostructured tungsten oxide. The sensing efficiency of this material determined as its adsorption capacity toward 54 ppb RDX was calculated to be five times higher than the sensing efficiency of a 54 ppb TNT vapor. The material sensing efficiency showed no dependence on the mass of material used. The results showed that the device allowed the calibration and discrimination between materials for highly sensitive and accurate sensing detection in air of low vapor pressure explosives such as TNT or RDX at subppb levels. The designed device and method showed promising features for nanosensing applications in the field of ultratrace explosive detection. The current perspectives are to decrease the testing scale and the detection levels to ppt or subppt concentration of explosives in air.

  5. Serum levels of organochlorine pesticides in the general population of Thessaly, Greece, determined by HS-SPME GC-MS method.

    PubMed

    Koureas, Michalis; Karagkouni, Foteini; Rakitskii, Valerii; Hadjichristodoulou, Christos; Tsatsakis, Aristidis; Tsakalof, Andreas

    2016-07-01

    In this study, exposure levels of organochlorine pesticides (OCs) were determined in general population residing in Larissa, central Greece. Serum samples from 103 volunteers were analyzed by optimized headspace solid-phase microextraction gas chromatography-mass spectrometry, to detect and quantify OC levels. The most frequently detected analytes were p,p'-DDE (frequency 99%, median:1.25ng/ml) and Hexachlorobenzene (HCB) (frequency 69%, median: 0.13ng/ml). Statistical analysis revealed a significant relationship of p,p'-DDE and HCB levels with age. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Accurate measurements of E2 lifetimes using the coincidence recoil-distance method

    NASA Astrophysics Data System (ADS)

    Bhalla, R. K.; Poletti, A. R.

    1984-05-01

    Mean lives of four E2 transitions in the (2s, 1d) shell have been measured using the recoil-distance method (RDM), γ-rays de-exciting the level of interest were detected in coincidence with particles detected in an annular detector at a backward angle thereby reducing the background and producing a beam of recoiling nuclei of well-defined energy and recoil direction. Lifetimes measured were: 22Ne, 1.275 MeV level (2 + → 0 +), 5.16±0.13 ps; 26Mg, 3.588 MeV level (0 + → 2 +), 9.29±0.23 ps; 30Si, 3.788 MeV level (0 +→ 2 +), 12.00±0.70 ps; 38Ar, 3.377 MeV level (0 + → 2 +), 34.5±1.5 ps. The present measurements are compared to those of previous investigators. For the 22Ne level, averaged results from four different measurement techniques are compared and found to be in good agreement. The experimental results are compared to shell-model calculations.

  7. Evaluation of the 3M™ Petrifilm™ Salmonella express system for the detection of Salmonella species in selected foods: collaborative study.

    PubMed

    Bird, Patrick; Flannery, Jonathan; Crowley, Erin; Agin, James; Goins, David; Jechorek, Robert

    2014-01-01

    The 3M™ Petriflm™ Salmonella Express (SALX) System is a simple, ready-to-use chromogenic culture medium system for the rapid qualitative detection and biochemical confirmation of Salmonella spp. in food and food process environmental samples. The 3M Petrifilm SALX System was compared using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) Microbiology Laboratory Guidebook (MLG) 4.07 (2013) Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products and Carcass and Environmental Sponges for raw ground beef and the U.S. Food and Drug Administration Bacteriological Analytical Manual (FDA/BAM) Chapter 5, Salmonella (2011) reference method for dry dog food following the current AOAC validation guidelines. For this study, a total of 17 laboratories located throughout the continental United States evaluated 1872 test portions. For the 3M Petrifilm SALX System, raw ground beef was analyzed using 25 g test portions, and dry dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each inatrix were analyzed. The two matrices were artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). Each inoculation level was statistically analyzed using the probability of detection statistical model. For the raw ground beef and dry dog food test portions, no significant differences at the 95% confidence interval were observed in the number of positive samples detected by the 3M Petrifilm SALX System versus either the USDA/FSIS-MLG or FDA/BAM methods.

  8. Improved detection of sugar addition to maple syrup using malic acid as internal standard and in 13C isotope ratio mass spectrometry (IRMS).

    PubMed

    Tremblay, Patrice; Paquin, Réal

    2007-01-24

    Stable carbon isotope ratio mass spectrometry (delta13C IRMS) was used to detect maple syrup adulteration by exogenous sugar addition (beet and cane sugar). Malic acid present in maple syrup is proposed as an isotopic internal standard to improve actual adulteration detection levels. A lead precipitation method has been modified to isolate quantitatively malic acid from maple syrup using preparative reversed-phase liquid chromatography. The stable carbon isotopic ratio of malic acid isolated from this procedure shows an excellent accuracy and repeatability of 0.01 and 0.1 per thousand respectively, confirming that the modified lead precipitation method is an isotopic fractionation-free process. A new approach is proposed to detect adulteration based on the correlation existing between the delta13Cmalic acid and the delta13Csugars-delta13Cmalic acid (r = 0.704). This technique has been tested on a set of 56 authentic maple syrup samples. Additionally, authentic samples were spiked with exogeneous sugars. The mean theoretical detection level was statistically lowered using this technique in comparison with the usual two-standard deviation approach, especially when maple syrup is adulterated with beet sugar : 24 +/- 12% of adulteration detection versus 48 +/- 20% (t-test, p = 7.3 x 10-15). The method was also applied to published data for pineapple juices and honey with the same improvement.

  9. Click chemistry-mediated cyclic cleavage of metal ion-dependent DNAzymes for amplified and colorimetric detection of human serum copper (II).

    PubMed

    Li, Daxiu; Xie, Jiaqing; Zhou, Wenjiao; Jiang, Bingying; Yuan, Ruo; Xiang, Yun

    2017-11-01

    The determination of the level of Cu 2+ plays important roles in disease diagnosis and environmental monitoring. By coupling Cu + -catalyzed click chemistry and metal ion-dependent DNAzyme cyclic amplification, we have developed a convenient and sensitive colorimetric sensing method for the detection of Cu 2+ in human serums. The target Cu 2+ can be reduced by ascorbate to form Cu + , which catalyzes the azide-alkyne cycloaddition between the azide- and alkyne-modified DNAs to form Mg 2+ -dependent DNAzymes. Subsequently, the Mg 2+ ions catalyze the cleavage of the hairpin DNA substrate sequences of the DNAzymes and trigger cyclic generation of a large number of free G-quadruplex sequences, which bind hemin to form the G-quadruplex/hemin artificial peroxidase to cause significant color transition of the sensing solution for sensitive colorimetric detection of Cu 2+ . This method shows a dynamic range of 5 to 500 nM and a detection limit of 2 nM for Cu 2+ detection. Besides, the level of Cu 2+ in human serums can also be determined by using this sensing approach. With the advantages of simplicity and high sensitivity, such sensing method thus holds great potential for on-site determination of Cu 2+ in different samples. Graphical abstract Sensitive colorimetric detection of copper (II) by coupling click chemistry with metal ion-dependentDNAzymes.

  10. Detection of myo-inositol trispyrophosphate in equine urine and plasma by hydrophillic interaction chromatography-tandem mass spectrometry.

    PubMed

    Wong, April S Y; Ho, Emmie N M; Wan, Terence S M

    2012-05-01

    Myo-inositol trispyrophosphate (ITPP) is a new drug capable of increasing the amount of oxygen in hypoxic tissues. Studies have shown that administration of ITPP increases the maximal exercise capacity in normal mice as well as mice with severe heart failure. The properties of ITPP make it an ideal candidate as a doping agent to enhance performance in racehorses. While there have been speculations in the horseracing industry that the covert use of ITPP is already widespread, no reported method exists for the detection of ITPP in equine biological samples. ITPP is a difficult-to-detect drug due to its hydrophilic nature; the complexity of equine biological matrices also adds to the problem. This paper describes for the first time a method for the detection and confirmation of ITPP in equine urine and plasma. ITPP was isolated from the sample matrices by solid-phase extraction and the extract was analyzed by hydrophilic interaction chromatography-tandem mass spectrometry. ITPP could be detected at low ppb levels in both fortified equine plasma and urine with good precision, fast instrumental turnaround time, and negligible matrix interferences. To our knowledge, this is the first report of a validated method for the detection and unequivocal confirmation of low levels of ITPP in any biological fluid. Copyright © 2012 John Wiley & Sons, Ltd.

  11. Fast Human Detection for Intelligent Monitoring Using Surveillance Visible Sensors

    PubMed Central

    Ko, Byoung Chul; Jeong, Mira; Nam, JaeYeal

    2014-01-01

    Human detection using visible surveillance sensors is an important and challenging work for intruder detection and safety management. The biggest barrier of real-time human detection is the computational time required for dense image scaling and scanning windows extracted from an entire image. This paper proposes fast human detection by selecting optimal levels of image scale using each level's adaptive region-of-interest (ROI). To estimate the image-scaling level, we generate a Hough windows map (HWM) and select a few optimal image scales based on the strength of the HWM and the divide-and-conquer algorithm. Furthermore, adaptive ROIs are arranged per image scale to provide a different search area. We employ a cascade random forests classifier to separate candidate windows into human and nonhuman classes. The proposed algorithm has been successfully applied to real-world surveillance video sequences, and its detection accuracy and computational speed show a better performance than those of other related methods. PMID:25393782

  12. High-Resolution Detection of Identity by Descent in Unrelated Individuals

    PubMed Central

    Browning, Sharon R.; Browning, Brian L.

    2010-01-01

    Detection of recent identity by descent (IBD) in population samples is important for population-based linkage mapping and for highly accurate genotype imputation and haplotype-phase inference. We present a method for detection of recent IBD in population samples. Our method accounts for linkage disequilibrium between SNPs to enable full use of high-density SNP data. We find that our method can detect segments of a length of 2 cM with moderate power and negligible false discovery rate in Illumina 550K data in Northwestern Europeans. We compare our method with GERMLINE and PLINK, and we show that our method has a level of resolution that is significantly better than these existing methods, thus extending the usefulness of recent IBD in analysis of high-density SNP data. We survey four genomic regions in a sample of UK individuals of European descent and find that on average, at a given location, our method detects IBD in 2.7 per 10,000 pairs of individuals in Illumina 550K data. We also present methodology and results for detection of homozygosity by descent (HBD) and survey the whole genome in a sample of 1373 UK individuals of European descent. We detect HBD in 4.7 individuals per 10,000 on average at a given location. Our methodology is implemented in the freely available BEAGLE software package. PMID:20303063

  13. Applying a 2D based CAD scheme for detecting micro-calcification clusters using digital breast tomosynthesis images: an assessment

    NASA Astrophysics Data System (ADS)

    Park, Sang Cheol; Zheng, Bin; Wang, Xiao-Hui; Gur, David

    2008-03-01

    Digital breast tomosynthesis (DBT) has emerged as a promising imaging modality for screening mammography. However, visually detecting micro-calcification clusters depicted on DBT images is a difficult task. Computer-aided detection (CAD) schemes for detecting micro-calcification clusters depicted on mammograms can achieve high performance and the use of CAD results can assist radiologists in detecting subtle micro-calcification clusters. In this study, we compared the performance of an available 2D based CAD scheme with one that includes a new grouping and scoring method when applied to both projection and reconstructed DBT images. We selected a dataset involving 96 DBT examinations acquired on 45 women. Each DBT image set included 11 low dose projection images and a varying number of reconstructed image slices ranging from 18 to 87. In this dataset 20 true-positive micro-calcification clusters were visually detected on the projection images and 40 were visually detected on the reconstructed images, respectively. We first applied the CAD scheme that was previously developed in our laboratory to the DBT dataset. We then tested a new grouping method that defines an independent cluster by grouping the same cluster detected on different projection or reconstructed images. We then compared four scoring methods to assess the CAD performance. The maximum sensitivity level observed for the different grouping and scoring methods were 70% and 88% for the projection and reconstructed images with a maximum false-positive rate of 4.0 and 15.9 per examination, respectively. This preliminary study demonstrates that (1) among the maximum, the minimum or the average CAD generated scores, using the maximum score of the grouped cluster regions achieved the highest performance level, (2) the histogram based scoring method is reasonably effective in reducing false-positive detections on the projection images but the overall CAD sensitivity is lower due to lower signal-to-noise ratio, and (3) CAD achieved higher sensitivity and higher false-positive rate (per examination) on the reconstructed images. We concluded that without changing the detection threshold or performing pre-filtering to possibly increase detection sensitivity, current CAD schemes developed and optimized for 2D mammograms perform relatively poorly and need to be re-optimized using DBT datasets and new grouping and scoring methods need to be incorporated into the schemes if these are to be used on the DBT examinations.

  14. Determination of acaricide residues in saudi arabian honey and beeswax using solid phase extraction and gas chromatography.

    PubMed

    Kamel, Alaa; Al-Ghamdi, Ahmad

    2006-01-01

    Determination of acaricide residues of flumethrin, tau-fluvalinate, coumaphos, and amitraz in honey and beeswax was carried out using a rapid extraction method utilizing C-18 SPE cartridges and an analytical method utilizing GC with ECD, NPD, and MSD detectors for the four acaricides. Recovery percentages from the extraction method ranged from 90-102%, while the minimum detection levels ranged from 0.01-0.05 mg/kg for the acaricides. Nine of the 21 analyzed samples were found to be contaminated with the acaricides tau-fluvalinate and coumaphos. Neither flumethrin nor amitraz was detected in any of the honey or wax samples. Coumaphos was found only in honey samples in which two samples exceeded the tolerance levels set by EPA and EC regulations. It has not been detected in beeswax. Five honey samples and eight beeswax samples were found to be contaminated with tau-fluvalinate. One of the wax samples was contaminated with a relatively high residue of tau-fluvalinate and contained above 10 mg/kg.

  15. Making great leaps forward: Accounting for detectability in herpetological field studies

    USGS Publications Warehouse

    Mazerolle, Marc J.; Bailey, Larissa L.; Kendall, William L.; Royle, J. Andrew; Converse, Sarah J.; Nichols, James D.

    2007-01-01

    Detecting individuals of amphibian and reptile species can be a daunting task. Detection can be hindered by various factors such as cryptic behavior, color patterns, or observer experience. These factors complicate the estimation of state variables of interest (e.g., abundance, occupancy, species richness) as well as the vital rates that induce changes in these state variables (e.g., survival probabilities for abundance; extinction probabilities for occupancy). Although ad hoc methods (e.g., counts uncorrected for detection, return rates) typically perform poorly in the face of no detection, they continue to be used extensively in various fields, including herpetology. However, formal approaches that estimate and account for the probability of detection, such as capture-mark-recapture (CMR) methods and distance sampling, are available. In this paper, we present classical approaches and recent advances in methods accounting for detectability that are particularly pertinent for herpetological data sets. Through examples, we illustrate the use of several methods, discuss their performance compared to that of ad hoc methods, and we suggest available software to perform these analyses. The methods we discuss control for imperfect detection and reduce bias in estimates of demographic parameters such as population size, survival, or, at other levels of biological organization, species occurrence. Among these methods, recently developed approaches that no longer require marked or resighted individuals should be particularly of interest to field herpetologists. We hope that our effort will encourage practitioners to implement some of the estimation methods presented herein instead of relying on ad hoc methods that make more limiting assumptions.

  16. Quantitative method of measuring cancer cell urokinase and metastatic potential

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R. (Inventor)

    1993-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated urokinase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  17. A Direct and Rapid Method to Determine Cyanide in Urine by Capillary Electrophoresis

    PubMed Central

    Zhang, Qiyang; Maddukuri, Naveen; Gong, Maojun

    2015-01-01

    Cyanides are poisonous chemicals that widely exist in nature and industrial processes as well as accidental fires. Rapid and accurate determination of cyanide exposure would facilitate forensic investigation, medical diagnosis, and chronic cyanide monitoring. Here, a rapid and direct method was developed for the determination of cyanide ions in urinary samples. This technique was based on an integrated capillary electrophoresis system coupled with laser-induced fluorescence (LIF) detection. Cyanide ions were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and a primary amine (glycine) for LIF detection. Three separate reagents, NDA, glycine, and cyanide sample, were mixed online, which secured uniform conditions between samples for cyanide derivatization and reduced the risk of precipitation formation of mixtures. Conditions were optimized; the derivatization was completed in 2-4 minutes, and the separation was observed in 25 s. The limit of detection (LOD) was 4.0 nM at 3-fold signal-to-noise ratio for standard cyanide in buffer. The cyanide levels in urine samples from smokers and non-smokers were determined by using the method of standard addition, which demonstrated significant difference of cyanide levels in urinary samples from the two groups of people. The developed method was rapid and accurate, and is anticipated to be applicable to cyanide detection in waste water with appropriate modification. PMID:26342870

  18. A high-performance seizure detection algorithm based on Discrete Wavelet Transform (DWT) and EEG

    PubMed Central

    Chen, Duo; Wan, Suiren; Xiang, Jing; Bao, Forrest Sheng

    2017-01-01

    In the past decade, Discrete Wavelet Transform (DWT), a powerful time-frequency tool, has been widely used in computer-aided signal analysis of epileptic electroencephalography (EEG), such as the detection of seizures. One of the important hurdles in the applications of DWT is the settings of DWT, which are chosen empirically or arbitrarily in previous works. The objective of this study aimed to develop a framework for automatically searching the optimal DWT settings to improve accuracy and to reduce computational cost of seizure detection. To address this, we developed a method to decompose EEG data into 7 commonly used wavelet families, to the maximum theoretical level of each mother wavelet. Wavelets and decomposition levels providing the highest accuracy in each wavelet family were then searched in an exhaustive selection of frequency bands, which showed optimal accuracy and low computational cost. The selection of frequency bands and features removed approximately 40% of redundancies. The developed algorithm achieved promising performance on two well-tested EEG datasets (accuracy >90% for both datasets). The experimental results of the developed method have demonstrated that the settings of DWT affect its performance on seizure detection substantially. Compared with existing seizure detection methods based on wavelet, the new approach is more accurate and transferable among datasets. PMID:28278203

  19. Endpoint visual detection of three genetically modified rice events by loop-mediated isothermal amplification.

    PubMed

    Chen, Xiaoyun; Wang, Xiaofu; Jin, Nuo; Zhou, Yu; Huang, Sainan; Miao, Qingmei; Zhu, Qing; Xu, Junfeng

    2012-11-07

    Genetically modified (GM) rice KMD1, TT51-1, and KF6 are three of the most well known transgenic Bt rice lines in China. A rapid and sensitive molecular assay for risk assessment of GM rice is needed. Polymerase chain reaction (PCR), currently the most common method for detecting genetically modified organisms, requires temperature cycling and relatively complex procedures. Here we developed a visual and rapid loop-mediated isothermal amplification (LAMP) method to amplify three GM rice event-specific junction sequences. Target DNA was amplified and visualized by two indicators (SYBR green or hydroxy naphthol blue [HNB]) within 60 min at an isothermal temperature of 63 °C. Different kinds of plants were selected to ensure the specificity of detection and the results of the non-target samples were negative, indicating that the primer sets for the three GM rice varieties had good levels of specificity. The sensitivity of LAMP, with detection limits at low concentration levels (0.01%−0.005% GM), was 10- to 100-fold greater than that of conventional PCR. Additionally, the LAMP assay coupled with an indicator (SYBR green or HNB) facilitated analysis. These findings revealed that the rapid detection method was suitable as a simple field-based test to determine the status of GM crops.

  20. An overview of the legislation and light microscopy for detection of processed animal proteins in feeds.

    PubMed

    Liu, Xian; Han, Lujia; Veys, Pascal; Baeten, Vincent; Jiang, Xunpeng; Dardenne, Pierre

    2011-08-01

    From the first cases of bovine spongiform encephalopathy (BSE) among cattle in the United Kingdom in 1986, the route of infection of BSE is generally believed by means of feeds containing low level of processed animal proteins (PAPs). Therefore, many feed bans and alternative and complementary techniques were resulted for the BSE safeguards in the world. Now the feed bans are expected to develop into a "species to species" ban, which requires the corresponding species-specific identification methods. Currently, banned PAPs can be detected by various methods as light microscopy, polymerase chain reaction, enzyme-linked immunosorbent assay, near infrared spectroscopy, and near infrared microscopy. Light microscopy as described in the recent Commission Regulation EC/152/2009 is the only official method for the detection and characterization of PAPs in feed in the European Union. It is able to detect the presence of constituents of animal origin in feed at the level of 1 g/kg with hardly any false negative. Nevertheless, light microscopy has the limitation of lack of species specificity. This article presents a review of legislations on the use of PAPs in feedstuff, the detection details of animal proteins by light microscopy, and also presents and discusses the analysis procedure and expected development of the technique. Copyright © 2010 Wiley-Liss, Inc.

  1. Development and application of loop-mediated isothermal amplification (LAMP) for detection of Plasmopara viticola

    PubMed Central

    Kong, Xiangjiu; Qin, Wentao; Huang, Xiaoqing; Kong, Fanfang; Schoen, Cor D.; Feng, Jie; Wang, Zhongyue; Zhang, Hao

    2016-01-01

    A rapid LAMP (loop-mediated isothermal amplification) detection method was developed on the basis of the ITS sequence of P. viticola, the major causal agent of grape downy mildew. Among the 38 fungal and oomycete species tested, DNA isolated exclusively from P. viticola resulted in a specific product after LAMP amplification. This assay had high sensitivity and was able to detect the presence of less than 33 fg of genomic DNA per 25-μL reaction within 30 min. The infected leaves may produce sporangia that serve as a secondary inoculum. The developed LAMP assay is efficient for estimating the latent infection of grape leaves by P. viticola. When combined with the rapid and simple DNA extraction method, this assay’s total detection time is shortened to approximately one hour; therefore it is suitable for on-site detection of latent infection in the field. The sporangia levels in the air are strongly associated with disease severity. The LAMP method was also demonstrated to be able to estimate the level of sporangia released in the air in a certain period. This assay should make disease forecasting more accurate and rapid and should be helpful in decision-making regarding the control of grape downy mildew. PMID:27363943

  2. Detecting measurement outliers: remeasure efficiently

    NASA Astrophysics Data System (ADS)

    Ullrich, Albrecht

    2010-09-01

    Shrinking structures, advanced optical proximity correction (OPC) and complex measurement strategies continually challenge critical dimension (CD) metrology tools and recipe creation processes. One important quality ensuring task is the control of measurement outlier behavior. Outliers could trigger false positive alarm for specification violations impacting cycle time or potentially yield. Constant high level of outliers not only deteriorates cycle time but also puts unnecessary stress on tool operators leading eventually to human errors. At tool level the sources of outliers are natural variations (e.g. beam current etc.), drifts, contrast conditions, focus determination or pattern recognition issues, etc. Some of these can result from suboptimal or even wrong recipe settings, like focus position or measurement box size. Such outliers, created by an automatic recipe creation process faced with more complicated structures, would manifest itself rather as systematic variation of measurements than the one caused by 'pure' tool variation. I analyzed several statistical methods to detect outliers. These range from classical outlier tests for extrema, robust metrics like interquartile range (IQR) to methods evaluating the distribution of different populations of measurement sites, like the Cochran test. The latter suits especially the detection of systematic effects. The next level of outlier detection entwines additional information about the mask and the manufacturing process with the measurement results. The methods were reviewed for measured variations assumed to be normally distributed with zero mean but also for the presence of a statistically significant spatial process signature. I arrive at the conclusion that intelligent outlier detection can influence the efficiency and cycle time of CD metrology greatly. In combination with process information like target, typical platform variation and signature, one can tailor the detection to the needs of the photomask at hand. By monitoring the outlier behavior carefully, weaknesses of the automatic recipe creation process can be spotted.

  3. Establishment of a simple and quantitative immunospot assay for detecting anti-type II collagen antibody using an infrared fluorescence imaging system (IFIS).

    PubMed

    Ota, Shusuke; Kanazawa, Satoshi; Kobayashi, Masaaki; Otsuka, Takanobu; Okamoto, Takashi

    2005-04-01

    Antibodies to type II collagen (col II) have been detected in patients with rheumatoid arthritis and in animal models of collagen induced arthritis. Here, we describe a novel method to detect anti-col II antibodies using an immunospot assay with an infrared fluorescence imaging system. This method showed very high sensitivity and specificity, and was simple, with low background levels. It also showed higher reproducibility and linearity, with a dynamic range of approximately 500-fold, than the conventional immunospot assay with enhanced chemiluminescence detection. Using this method we were able to demonstrate the antibody affinity maturation process in mice immunized with col II. In these immunized mice, although cross-reactive antibodies reacting with other collagen species were detected in earlier stages of immunization, the titers of cross-reactive antibodies rapidly diminished after the antigen boost, concomitantly with the elevation of the anti-col II antibody. The method and its possible applications are discussed.

  4. A rapid and simple method of detection of Blepharisma japonicum using PCR and immobilisation on FTA paper

    PubMed Central

    Hide, Geoff; Hughes, Jacqueline M; McNuff, Robert

    2003-01-01

    Background The rapid expansion in the availability of genome and DNA sequence information has opened up new possibilities for the development of methods for detecting free-living protozoa in environmental samples. The protozoan Blepharisma japonicum was used to investigate a rapid and simple detection system based on polymerase chain reaction amplification (PCR) from organisms immobilised on FTA paper. Results Using primers designed from the α-tubulin genes of Blepharisma, specific and sensitive detection to the equivalent of a single Blepharisma cell could be achieved. Similar detection levels were found using water samples, containing Blepharisma, which were dried onto Whatman FTA paper. Conclusion This system has potential as a sensitive convenient detection system for Blepharisma and could be applied to other protozoan organisms. PMID:14516472

  5. Detection of regional DNA methylation using DNA-graphene affinity interactions.

    PubMed

    Haque, Md Hakimul; Gopalan, Vinod; Yadav, Sharda; Islam, Md Nazmul; Eftekhari, Ehsan; Li, Qin; Carrascosa, Laura G; Nguyen, Nam-Trung; Lam, Alfred K; Shiddiky, Muhammad J A

    2017-01-15

    We report a new method for the detection of regional DNA methylation using base-dependent affinity interaction (i.e., adsorption) of DNA with graphene. Due to the strongest adsorption affinity of guanine bases towards graphene, bisulfite-treated guanine-enriched methylated DNA leads to a larger amount of the adsorbed DNA on the graphene-modified electrodes in comparison to the adenine-enriched unmethylated DNA. The level of the methylation is quantified by monitoring the differential pulse voltammetric current as a function of the adsorbed DNA. The assay is sensitive to distinguish methylated and unmethylated DNA sequences at single CpG resolution by differentiating changes in DNA methylation as low as 5%. Furthermore, this method has been used to detect methylation levels in a collection of DNA samples taken from oesophageal cancer tissues. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Evaluation of a combined triple method to detect causative HPV in oral and oropharyngeal squamous cell carcinomas: p16 Immunohistochemistry, Consensus PCR HPV-DNA, and In Situ Hybridization

    PubMed Central

    2012-01-01

    Background Recent emerging evidences identify Human Papillomavirus (HPV) related Head and Neck squamous cell carcinomas (HN-SCCs) as a separate subgroup among Head and Neck Cancers with different epidemiology, histopathological characteristics, therapeutic response to chemo-radiation treatment and clinical outcome. However, there is not a worldwide consensus on the methods to be used in clinical practice. The endpoint of this study was to demonstrate the reliability of a triple method which combines evaluation of: 1. p16 protein expression by immunohistochemistry (p16-IHC); 2. HPV-DNA genotyping by consensus HPV-DNA PCR methods (Consensus PCR); and 3 viral integration into the host by in situ hybridization method (ISH). This triple method has been applied to HN-SCC originated from oral cavity (OSCC) and oropharynx (OPSCC), the two anatomical sites in which high risk (HR) HPVs have been clearly implicated as etiologic factors. Methylation-Specific PCR (MSP) was performed to study inactivation of p16-CDKN2a locus by epigenetic events. Reliability of multiple methods was measured by Kappa statistics. Results All the HN-SCCs confirmed HPV positive by PCR and/or ISH were also p16 positive by IHC, with the latter showing a very high level of sensitivity as single test (100% in both OSCC and OPSCC) but lower specificity level (74% in OSCC and 93% in OPSCC). Concordance analysis between ISH and Consensus PCR showed a faint agreement in OPSCC (κ = 0.38) and a moderate agreement in OSCC (κ = 0.44). Furthermore, the addition of double positive score (ISHpositive and Consensus PCR positive) increased significantly the specificity of HR-HPV detection on formalin-fixed paraffin embedded (FFPE) samples (100% in OSCC and 78.5% in OPSCC), but reduced the sensitivity (33% in OSCC and 60% in OPSCC). The significant reduction of sensitivity by the double method was compensated by a very high sensitivity of p16-IHC detection in the triple approach. Conclusions Although HR-HPVs detection is of utmost importance in clinical settings for the Head and Neck Cancer patients, there is no consensus on which to consider the 'golden standard' among the numerous detection methods available either as single test or combinations. Until recently, quantitative E6 RNA PCR has been considered the 'golden standard' since it was demonstrated to have very high accuracy level and very high statistical significance associated with prognostic parameters. In contrast, quantitative E6 DNA PCR has proven to have very high level of accuracy but lesser prognostic association with clinical outcome than the HPV E6 oncoprotein RNA PCR. However, although it is theoretically possible to perform quantitative PCR detection methods also on FFPE samples, they reach the maximum of accuracy on fresh frozen tissue. Furthermore, worldwide diagnostic laboratories have not all the same ability to analyze simultaneously both FFPE and fresh tissues with these quantitative molecular detection methods. Therefore, in the current clinical practice a p16-IHC test is considered as sufficient for HPV diagnostic in accordance with the recently published Head and Neck Cancer international guidelines. Although p16-IHC may serve as a good prognostic indicator, our study clearly demonstrated that it is not satisfactory when used exclusively as the only HPV detecting method. Adding ISH, although known as less sensitive than PCR-based detection methods, has the advantage to preserve the morphological context of HPV-DNA signals in FFPE samples and, thus increase the overall specificity of p16/Consensus PCR combination tests. PMID:22376902

  7. Validation of a pressurized solvent extraction and GC-NCI-MS method for the low level determination of 40 polybrominated diphenyl ethers in mothers' milk.

    PubMed

    Lacorte, Silvia; Guillamon, Míriam

    2008-08-01

    This study reports an efficient method for the determination of 40 PBDEs from mono- to hepta-brominated in human milk. Pressurized liquid extraction (PLE) was optimized to recover PBDEs in a quantitative way using 1g of freeze dried milk. Due to the great amount of coextracted compounds, the clean-up step was optimized using alumina SPE disposable cartridges of 2 and 5 g. Whereas 2g alumina SPE failed in providing good extraction yields, all PBDEs were satisfactorily recovered using 5 g alumina SPE cartridges. Detection was performed with gas chromatography coupled to mass spectrometry with negative chemical ionization and method detection limits ranged from 0.01 to 0.05 microg kg(-1) wet weight (ww) with a good intra and inter-day variation (coefficient of variation lower than 13.4%). This method was validated by participating in an interlaboratory exercise from Quasimeme (United Kingdom), where a standard solution containing seven congeners and a certified unspiked mothers' milk were analyzed. In the standard mixture, levels between 96.915 and 570.172 microg l(-1) were quantified, whereas in certified mothers' milk, BDEs 47, 99, 100 and 154 were detected at levels from 0.010 and 0.061 microg kg(-1) ww, with an error <30%. The applicability of the method was tested experimentally in five mothers' milk samples, where only BDE 47 was detected at a maximum concentration of 10.45 microg kg(-1) lipid weight (lw). PLE succeeded in extracting all PBDEs from the sample with good reproducibility although the clean-up step had to be severely performed to eliminate sample interferences such as milk lipids and proteins.

  8. Computer-aided detection of bladder masses in CT urography (CTU)

    NASA Astrophysics Data System (ADS)

    Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon; Samala, Ravi K.

    2017-03-01

    We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). We have previously developed methods for detection of bladder masses within the contrast-enhanced and the non-contrastenhanced regions of the bladder individually. In this study, we investigated methods for detection of bladder masses within the entire bladder. The bladder was segmented using our method that combined deep-learning convolutional neural network with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensity-projection-based method. The non-contrast region was smoothed and gray level threshold was applied to the contrast and non-contrast regions separately to extract the bladder wall and potential masses. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify lesion candidates in a prescreening step. The candidates were mapped back to the 3D CT volume and segmented using our auto-initialized cascaded level set (AI-CALS) segmentation method. Twenty-seven morphological features were extracted for each candidate. A data set of 57 patients with 71 biopsy-proven bladder lesions was used, which was split into independent training and test sets: 42 training cases with 52 lesions, and 15 test cases with 19 lesions. Using the training set, feature selection was performed and a linear discriminant (LDA) classifier was designed to merge the selected features for classification of bladder lesions and false positives. The trained classifier was evaluated with the test set. FROC analysis showed that the system achieved a sensitivity of 86.5% at 3.3 FPs/case for the training set, and 84.2% at 3.7 FPs/case for the test set.

  9. Detection of diluted contaminants on chicken carcasses using a two-dimensional scatter plot based on a two-dimensional hyperspectral correlation spectrum.

    PubMed

    Wu, Wei; Chen, Gui-Yun; Wu, Ming-Qing; Yu, Zhen-Wei; Chen, Kun-Jie

    2017-03-20

    A two-dimensional (2D) scatter plot method based on the 2D hyperspectral correlation spectrum is proposed to detect diluted blood, bile, and feces from the cecum and duodenum on chicken carcasses. First, from the collected hyperspectral data, a set of uncontaminated regions of interest (ROIs) and four sets of contaminated ROIs were selected, whose average spectra were treated as the original spectrum and influenced spectra, respectively. Then, the difference spectra were obtained and used to conduct correlation analysis, from which the 2D hyperspectral correlation spectrum was constructed using the analogy method of 2D IR correlation spectroscopy. Two maximum auto-peaks and a pair of cross peaks appeared at 656 and 474 nm. Therefore, 656 and 474 nm were selected as the characteristic bands because they were most sensitive to the spectral change induced by the contaminants. The 2D scatter plots of the contaminants, clean skin, and background in the 474- and 656-nm space were used to distinguish the contaminants from the clean skin and background. The threshold values of the 474- and 656-nm bands were determined by receiver operating characteristic (ROC) analysis. According to the ROC results, a pixel whose relative reflectance at 656 nm was greater than 0.5 and relative reflectance at 474 nm was lower than 0.3 was judged as a contaminated pixel. A region with more than 50 pixels identified was marked in the detection graph. This detection method achieved a recognition rate of up to 95.03% at the region level and 31.84% at the pixel level. The false-positive rate was only 0.82% at the pixel level. The results of this study confirm that the 2D scatter plot method based on the 2D hyperspectral correlation spectrum is an effective method for detecting diluted contaminants on chicken carcasses.

  10. Inductive System for Reliable Magnesium Level Detection in a Titanium Reduction Reactor

    NASA Astrophysics Data System (ADS)

    Krauter, Nico; Eckert, Sven; Gundrum, Thomas; Stefani, Frank; Wondrak, Thomas; Frick, Peter; Khalilov, Ruslan; Teimurazov, Andrei

    2018-05-01

    The determination of the Magnesium level in a Titanium reduction retort by inductive methods is often hampered by the formation of Titanium sponge rings which disturb the propagation of electromagnetic signals between excitation and receiver coils. We present a new method for the reliable identification of the Magnesium level which explicitly takes into account the presence of sponge rings with unknown geometry and conductivity. The inverse problem is solved by a look-up-table method, based on the solution of the inductive forward problems for several tens of thousands parameter combinations.

  11. Detection of Pseudomonas savastanoi pv. savastanoi in olive plants by enrichment and PCR.

    PubMed

    Penyalver, R; García, A; Ferrer, A; Bertolini, E; López, M M

    2000-06-01

    The sequence of the gene iaaL of Pseudomonas savastanoi EW2009 was used to design primers for PCR amplification. The iaaL-derived primers directed the amplification of a 454-bp fragment from genomic DNA isolated from 70 strains of P. savastanoi, whereas genomic DNA from 93 non-P. savastanoi isolates did not yield this amplified product. A previous bacterial enrichment in the semiselective liquid medium PVF-1 improved the PCR sensitivity level, allowing detection of 10 to 100 CFU/ml of plant extract. P. savastanoi was detected by the developed enrichment-PCR method in knots from different varieties of inoculated and naturally infected olive trees. Moreover, P. savastanoi was detected in symptomless stem tissues from naturally infected olive plants. This enrichment-PCR method is more sensitive and less cumbersome than the conventional isolation methods for detection of P. savastanoi.

  12. Detecting and Estimating Contamination of Human DNA Samples in Sequencing and Array-Based Genotype Data

    PubMed Central

    Jun, Goo; Flickinger, Matthew; Hetrick, Kurt N.; Romm, Jane M.; Doheny, Kimberly F.; Abecasis, Gonçalo R.; Boehnke, Michael; Kang, Hyun Min

    2012-01-01

    DNA sample contamination is a serious problem in DNA sequencing studies and may result in systematic genotype misclassification and false positive associations. Although methods exist to detect and filter out cross-species contamination, few methods to detect within-species sample contamination are available. In this paper, we describe methods to identify within-species DNA sample contamination based on (1) a combination of sequencing reads and array-based genotype data, (2) sequence reads alone, and (3) array-based genotype data alone. Analysis of sequencing reads allows contamination detection after sequence data is generated but prior to variant calling; analysis of array-based genotype data allows contamination detection prior to generation of costly sequence data. Through a combination of analysis of in silico and experimentally contaminated samples, we show that our methods can reliably detect and estimate levels of contamination as low as 1%. We evaluate the impact of DNA contamination on genotype accuracy and propose effective strategies to screen for and prevent DNA contamination in sequencing studies. PMID:23103226

  13. Sunglass detection method for automation of video surveillance system

    NASA Astrophysics Data System (ADS)

    Sikandar, Tasriva; Samsudin, Wan Nur Azhani W.; Hawari Ghazali, Kamarul; Mohd, Izzeldin I.; Fazle Rabbi, Mohammad

    2018-04-01

    Wearing sunglass to hide face from surveillance camera is a common activity in criminal incidences. Therefore, sunglass detection from surveillance video has become a demanding issue in automation of security systems. In this paper we propose an image processing method to detect sunglass from surveillance images. Specifically, a unique feature using facial height and width has been employed to identify the covered region of the face. The presence of covered area by sunglass is evaluated using facial height-width ratio. Threshold value of covered area percentage is used to classify the glass wearing face. Two different types of glasses have been considered i.e. eye glass and sunglass. The results of this study demonstrate that the proposed method is able to detect sunglasses in two different illumination conditions such as, room illumination as well as in the presence of sunlight. In addition, due to the multi-level checking in facial region, this method has 100% accuracy of detecting sunglass. However, in an exceptional case where fabric surrounding the face has similar color as skin, the correct detection rate was found 93.33% for eye glass.

  14. PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites.

    PubMed

    Gerwin, Philip M; Ricart Arbona, Rodolfo J; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S

    2017-11-01

    We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite-infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method.

  15. Millimeter-Wave Spectroscopy for Analytical Chemistry: Thermal Evolution of Low Volatility Impurities and Detection with a Fourier Transform Molecular Rotational Resonance Spectrometer (tev Ft-Mrr

    NASA Astrophysics Data System (ADS)

    Harris, Brent; Fields, Shelby S.; Neill, Justin L.; Pulliam, Robin; Muckle, Matt; Pate, Brooks

    2016-06-01

    Recent advances in Fourier transform millimeter-wave spectroscopy techniques have renewed the application reach of molecular rotational spectroscopy for analytical chemistry. We present a sampling method for sub ppm analysis of low volatility impurities by thermal evolution from solid powders using a millimeter-wave Fourier transform molecular rotational resonance (FT-MRR) spectrometer for detection. This application of FT-MRR is relevant to the manufacturing of safe oral pharmaceuticals. Low volatility impurities can be challenging to detect at 1 ppm levels with chromatographic techniques. One such example of a potentially mutagenic impurity is acetamide (v.p. 1 Torr at 40 C, m.p. 80 C). We measured the pure reference spectrum of acetamide by flowing the sublimated vapor pressure of acetamide crystals through the FT-MRR spectrometer. The spectrometer lower detection level (LDL) for a broadband (> 20 GHz, 10 min.) spectrum is 300 nTorr, 30 pmol, or 2 ng. For a 50 mg powder, perfect sample transfer efficiency can yield a w/w % detection limit of 35 ppb. We extended the sampling method for the acetamide reference measurement to an acetaminophen sample spiked with 5000 ppm acetamide in order to test the sample transfer efficiency when liberated from an pharmaceutical powder. A spectral reference matching algorithm detected the presence of several impurities including acetaldehyde, acetic acid, and acetonitrile that evolved at the melting point of acetaminophen, demonstrating the capability of FT-MRR for identification without a routine chemical standard. The method detection limit (MDL) without further development is less than 10 ppm w/w %. Resolved FT-MRR mixture spectra will be presented with a description of sampling methods.

  16. PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites

    PubMed Central

    Gerwin, Philip M; Arbona, Rodolfo J Ricart; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S

    2017-01-01

    We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite- infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method. PMID:29256370

  17. Detecting unresolved binary stars in Euclid VIS images

    NASA Astrophysics Data System (ADS)

    Kuntzer, T.; Courbin, F.

    2017-10-01

    Measuring a weak gravitational lensing signal to the level required by the next generation of space-based surveys demands exquisite reconstruction of the point-spread function (PSF). However, unresolved binary stars can significantly distort the PSF shape. In an effort to mitigate this bias, we aim at detecting unresolved binaries in realistic Euclid stellar populations. We tested methods in numerical experiments where (I) the PSF shape is known to Euclid requirements across the field of view; and (II) the PSF shape is unknown. We drew simulated catalogues of PSF shapes for this proof-of-concept paper. Following the Euclid survey plan, the objects were observed four times. We propose three methods to detect unresolved binary stars. The detection is based on the systematic and correlated biases between exposures of the same object. One method is a simple correlation analysis, while the two others use supervised machine-learning algorithms (random forest and artificial neural network). In both experiments, we demonstrate the ability of our methods to detect unresolved binary stars in simulated catalogues. The performance depends on the level of prior knowledge of the PSF shape and the shape measurement errors. Good detection performances are observed in both experiments. Full complexity, in terms of the images and the survey design, is not included, but key aspects of a more mature pipeline are discussed. Finding unresolved binaries in objects used for PSF reconstruction increases the quality of the PSF determination at arbitrary positions. We show, using different approaches, that we are able to detect at least binary stars that are most damaging for the PSF reconstruction process. The code corresponding to the algorithms used in this work and all scripts to reproduce the results are publicly available from a GitHub repository accessible via http://lastro.epfl.ch/software

  18. Highly sensitive and quantitative detection of rare pathogens through agarose droplet microfluidic emulsion PCR at the single-cell level.

    PubMed

    Zhu, Zhi; Zhang, Wenhua; Leng, Xuefei; Zhang, Mingxia; Guan, Zhichao; Lu, Jiangquan; Yang, Chaoyong James

    2012-10-21

    Genetic alternations can serve as highly specific biomarkers to distinguish fatal bacteria or cancer cells from their normal counterparts. However, these mutations normally exist in very rare amount in the presence of a large excess of non-mutated analogs. Taking the notorious pathogen E. coli O157:H7 as the target analyte, we have developed an agarose droplet-based microfluidic ePCR method for highly sensitive, specific and quantitative detection of rare pathogens in the high background of normal bacteria. Massively parallel singleplex and multiplex PCR at the single-cell level in agarose droplets have been successfully established. Moreover, we challenged the system with rare pathogen detection and realized the sensitive and quantitative analysis of a single E. coli O157:H7 cell in the high background of 100,000 excess normal K12 cells. For the first time, we demonstrated rare pathogen detection through agarose droplet microfluidic ePCR. Such a multiplex single-cell agarose droplet amplification method enables ultra-high throughput and multi-parameter genetic analysis of large population of cells at the single-cell level to uncover the stochastic variations in biological systems.

  19. Using rewards and penalties to obtain desired subject performance

    NASA Technical Reports Server (NTRS)

    Cook, M.; Jex, H. R.; Stein, A. C.; Allen, R. W.

    1981-01-01

    Operant conditioning procedures, specifically the use of negative reinforcement, in achieving stable learning behavior is described. The critical tracking test (CTT) a method of detecting human operator impairment was tested. A pass level is set for each subject, based on that subject's asymptotic skill level while sober. It is critical that complete training take place before the individualized pass level is set in order that the impairment can be detected. The results provide a more general basis for the application of reward/penalty structures in manual control research.

  20. Adaboost multi-view face detection based on YCgCr skin color model

    NASA Astrophysics Data System (ADS)

    Lan, Qi; Xu, Zhiyong

    2016-09-01

    Traditional Adaboost face detection algorithm uses Haar-like features training face classifiers, whose detection error rate is low in the face region. While under the complex background, the classifiers will make wrong detection easily to the background regions with the similar faces gray level distribution, which leads to the error detection rate of traditional Adaboost algorithm is high. As one of the most important features of a face, skin in YCgCr color space has good clustering. We can fast exclude the non-face areas through the skin color model. Therefore, combining with the advantages of the Adaboost algorithm and skin color detection algorithm, this paper proposes Adaboost face detection algorithm method that bases on YCgCr skin color model. Experiments show that, compared with traditional algorithm, the method we proposed has improved significantly in the detection accuracy and errors.

  1. The relationship between species detection probability and local extinction probability

    USGS Publications Warehouse

    Alpizar-Jara, R.; Nichols, J.D.; Hines, J.E.; Sauer, J.R.; Pollock, K.H.; Rosenberry, C.S.

    2004-01-01

    In community-level ecological studies, generally not all species present in sampled areas are detected. Many authors have proposed the use of estimation methods that allow detection probabilities that are < 1 and that are heterogeneous among species. These methods can also be used to estimate community-dynamic parameters such as species local extinction probability and turnover rates (Nichols et al. Ecol Appl 8:1213-1225; Conserv Biol 12:1390-1398). Here, we present an ad hoc approach to estimating community-level vital rates in the presence of joint heterogeneity of detection probabilities and vital rates. The method consists of partitioning the number of species into two groups using the detection frequencies and then estimating vital rates (e.g., local extinction probabilities) for each group. Estimators from each group are combined in a weighted estimator of vital rates that accounts for the effect of heterogeneity. Using data from the North American Breeding Bird Survey, we computed such estimates and tested the hypothesis that detection probabilities and local extinction probabilities were negatively related. Our analyses support the hypothesis that species detection probability covaries negatively with local probability of extinction and turnover rates. A simulation study was conducted to assess the performance of vital parameter estimators as well as other estimators relevant to questions about heterogeneity, such as coefficient of variation of detection probabilities and proportion of species in each group. Both the weighted estimator suggested in this paper and the original unweighted estimator for local extinction probability performed fairly well and provided no basis for preferring one to the other.

  2. Detection of expression quantitative trait Loci in complex mouse crosses: impact and alleviation of data quality and complex population substructure.

    PubMed

    Iancu, Ovidiu D; Darakjian, Priscila; Kawane, Sunita; Bottomly, Daniel; Hitzemann, Robert; McWeeney, Shannon

    2012-01-01

    Complex Mus musculus crosses, e.g., heterogeneous stock (HS), provide increased resolution for quantitative trait loci detection. However, increased genetic complexity challenges detection methods, with discordant results due to low data quality or complex genetic architecture. We quantified the impact of theses factors across three mouse crosses and two different detection methods, identifying procedures that greatly improve detection quality. Importantly, HS populations have complex genetic architectures not fully captured by the whole genome kinship matrix, calling for incorporating chromosome specific relatedness information. We analyze three increasingly complex crosses, using gene expression levels as quantitative traits. The three crosses were an F(2) intercross, a HS formed by crossing four inbred strains (HS4), and a HS (HS-CC) derived from the eight lines found in the collaborative cross. Brain (striatum) gene expression and genotype data were obtained using the Illumina platform. We found large disparities between methods, with concordance varying as genetic complexity increased; this problem was more acute for probes with distant regulatory elements (trans). A suite of data filtering steps resulted in substantial increases in reproducibility. Genetic relatedness between samples generated overabundance of detected eQTLs; an adjustment procedure that includes the kinship matrix attenuates this problem. However, we find that relatedness between individuals is not evenly distributed across the genome; information from distinct chromosomes results in relatedness structure different from the whole genome kinship matrix. Shared polymorphisms from distinct chromosomes collectively affect expression levels, confounding eQTL detection. We suggest that considering chromosome specific relatedness can result in improved eQTL detection.

  3. [Cytogenetic characteristics of the uterine cervical epithelium in inflammatory diseases].

    PubMed

    Aleksieienko, O I

    2011-01-01

    Functional status of epithelial cells at inflammatory cervical pathologies has been studied with the use of cytogenetic method of detection of chromosome nucleolar organizer regions. The highest level of rRNA proliferation and synthesis has been detected in cylindrical epithelial cells using the indexes of compact and transitional nucleolonemic types of nucleolar organizer regions, a higher level--in squamous cells of intermediate type, and the lowest one in squamous epithelium of superficial type.

  4. Fighting detection using interaction energy force

    NASA Astrophysics Data System (ADS)

    Wateosot, Chonthisa; Suvonvorn, Nikom

    2017-02-01

    Fighting detection is an important issue in security aimed to prevent criminal or undesirable events in public places. Many researches on computer vision techniques have studied to detect the specific event in crowded scenes. In this paper we focus on fighting detection using social-based Interaction Energy Force (IEF). The method uses low level features without object extraction and tracking. The interaction force is modeled using the magnitude and direction of optical flows. A fighting factor is developed under this model to detect fighting events using thresholding method. An energy map of interaction force is also presented to identify the corresponding events. The evaluation is performed using NUSHGA and BEHAVE datasets. The results show the efficiency with high accuracy regardless of various conditions.

  5. Serological detection of ‘Candidatus Liberibacter asiaticus’ in citrus, and the identification of a promising secreted chaperone protein responding to cellular pathogens

    USDA-ARS?s Scientific Manuscript database

    Antibodies against ‘Candidatus Liberibacter asiaticus (CaLas) would be useful in inexpensive tissue print assays to detect the pathogen in infected plants. Such assays would provide low cost detection and a level of spatial and anatomical detail not possible with other methods like qPCR. We used S...

  6. Alarm characterization for continuous glucose monitors used as adjuncts to self-monitoring of blood glucose.

    PubMed

    McGarraugh, Geoffrey

    2010-01-01

    Continuous glucose monitoring (CGM) devices available in the United States are approved for use as adjuncts to self-monitoring of blood glucose (SMBG). Alarm evaluation in the Clinical and Laboratory Standards Institute (CLSI) guideline for CGM does not specifically address devices that employ both CGM and SMBG. In this report, an alarm evaluation method is proposed for these devices. The proposed method builds on the CLSI method using data from an in-clinic study of subjects with type 1 diabetes. CGM was used to detect glycemic events, and SMBG was used to determine treatment. To optimize detection of a single glucose level, such as 70 mg/dl, a range of alarm threshold settings was evaluated. The alarm characterization provides a choice of alarm settings that trade off detection and false alarms. Detection of a range of high glucose levels was similarly evaluated. Using low glucose alarms, detection of 70 mg/dl within 30 minutes increased from 64 to 97% as alarm settings increased from 70 to 100 mg/dl, and alarms that did not require treatment (SMBG >85 mg/dl) increased from 18 to 52%. Using high glucose alarms, detection of 180 mg/dl within 30 minutes increased from 87 to 96% as alarm settings decreased from 180 to 165 mg/dl, and alarms that did not require treatment (SMBG <180 mg/dl) increased from 24 to 42%. The proposed alarm evaluation method provides information for choosing appropriate alarm thresholds and reflects the clinical utility of CGM alarms. 2010 Diabetes Technology Society.

  7. Biosensor UUV payload for underwater detection

    NASA Astrophysics Data System (ADS)

    Kusterbeck, Anne W.; Charles, Paul T.; Melde, Brian J.; Trammell, Scott A.; Adams, André A.; Deschamps, Jeffrey R.

    2010-04-01

    Increased emphasis on maritime domain awareness and port security has led to the development of unmanned underwater vehicles (UUVs) capable of extended missions. These systems rely most frequently on well-developed side scan sonar and acoustic methods to locate potential targets. The Naval Research Laboratory (NRL) is developing biosensors for underwater explosives detection that complement acoustic sensors and can be used as UUV payloads to monitor areas for port and harbor security or in detection of underwater unexploded ordnance (UXO) and biochemical threats. The prototype sensor has recently been demonstrated to detect explosives in seawater at trace levels when run in a continuous sampling mode. To overcome ongoing issues with sample preparation and facilitate rapid detection at trace levels in a marine environment, we have been developing new mesoporous materials for in-line preconcentration of explosives and other small molecules, engineering microfluidic components to improve the signal, and testing alternative signal transduction methods. Additional work is being done to optimize the optical components and sensor response time. Highlights of these current studies and our ongoing efforts to integrate the biosensor with existing detection technologies to reduce false positives are described. In addition, we present the results of field tests that demonstrate the prototype biosensor performance as a UUV payload.

  8. Discrete Data Qualification System and Method Comprising Noise Series Fault Detection

    NASA Technical Reports Server (NTRS)

    Fulton, Christopher; Wong, Edmond; Melcher, Kevin; Bickford, Randall

    2013-01-01

    A Sensor Data Qualification (SDQ) function has been developed that allows the onboard flight computers on NASA s launch vehicles to determine the validity of sensor data to ensure that critical safety and operational decisions are not based on faulty sensor data. This SDQ function includes a novel noise series fault detection algorithm for qualification of the output data from LO2 and LH2 low-level liquid sensors. These sensors are positioned in a launch vehicle s propellant tanks in order to detect propellant depletion during a rocket engine s boost operating phase. This detection capability can prevent the catastrophic situation where the engine operates without propellant. The output from each LO2 and LH2 low-level liquid sensor is a discrete valued signal that is expected to be in either of two states, depending on whether the sensor is immersed (wet) or exposed (dry). Conventional methods for sensor data qualification, such as threshold limit checking, are not effective for this type of signal due to its discrete binary-state nature. To address this data qualification challenge, a noise computation and evaluation method, also known as a noise fault detector, was developed to detect unreasonable statistical characteristics in the discrete data stream. The method operates on a time series of discrete data observations over a moving window of data points and performs a continuous examination of the resulting observation stream to identify the presence of anomalous characteristics. If the method determines the existence of anomalous results, the data from the sensor is disqualified for use by other monitoring or control functions.

  9. The Genetic-Algorithm-Based Normal Boundary Intersection (GANBI) Method; An Efficient Approach to Pareto Multiobjective Optimization for Engineering Design

    DTIC Science & Technology

    2006-05-15

    alarm performance in a cost-effective manner is the use of track - before - detect strategies, in which multiple sensor detections must occur within the...corresponding to the traditional sensor coverage problem. Also, in the track - before - detect context, reference is made to the field-level functions of...detection and false alarm as successful search and false search, respectively, because the track - before - detect process serves as a searching function

  10. Inappropriate Fiddling with Statistical Analyses to Obtain a Desirable P-value: Tests to Detect its Presence in Published Literature

    PubMed Central

    Gadbury, Gary L.; Allison, David B.

    2012-01-01

    Much has been written regarding p-values below certain thresholds (most notably 0.05) denoting statistical significance and the tendency of such p-values to be more readily publishable in peer-reviewed journals. Intuition suggests that there may be a tendency to manipulate statistical analyses to push a “near significant p-value” to a level that is considered significant. This article presents a method for detecting the presence of such manipulation (herein called “fiddling”) in a distribution of p-values from independent studies. Simulations are used to illustrate the properties of the method. The results suggest that the method has low type I error and that power approaches acceptable levels as the number of p-values being studied approaches 1000. PMID:23056287

  11. Inappropriate fiddling with statistical analyses to obtain a desirable p-value: tests to detect its presence in published literature.

    PubMed

    Gadbury, Gary L; Allison, David B

    2012-01-01

    Much has been written regarding p-values below certain thresholds (most notably 0.05) denoting statistical significance and the tendency of such p-values to be more readily publishable in peer-reviewed journals. Intuition suggests that there may be a tendency to manipulate statistical analyses to push a "near significant p-value" to a level that is considered significant. This article presents a method for detecting the presence of such manipulation (herein called "fiddling") in a distribution of p-values from independent studies. Simulations are used to illustrate the properties of the method. The results suggest that the method has low type I error and that power approaches acceptable levels as the number of p-values being studied approaches 1000.

  12. Monitoring Colony-level Effects of Sublethal Pesticide Exposure on Honey Bees

    PubMed Central

    Meikle, William G.; Weiss, Milagra

    2017-01-01

    The effects of sublethal pesticide exposure to honey bee colonies may be significant but difficult to detect in the field using standard visual assessment methods. Here we describe methods to measure the quantities of adult bees, brood, and food resources by weighing hives and hive parts, by photographing frames, and by installing hives on scales and with internal sensors. Data from these periodic evaluations are then combined with running average and daily detrended data on hive weight and internal hive temperature. The resulting datasets have been used to detect colony-level effects of imidacloprid applied in a sugar syrup as low as 5 parts per billion. The methods are objective, require little training, and provide permanent records in the form of sensor output and photographs. PMID:29286367

  13. A cascade method for TFT-LCD defect detection

    NASA Astrophysics Data System (ADS)

    Yi, Songsong; Wu, Xiaojun; Yu, Zhiyang; Mo, Zhuoya

    2017-07-01

    In this paper, we propose a novel cascade detection algorithm which focuses on point and line defects on TFT-LCD. At the first step of the algorithm, we use the gray level difference of su-bimage to segment the abnormal area. The second step is based on phase only transform (POT) which corresponds to the Discrete Fourier Transform (DFT), normalized by the magnitude. It can remove regularities like texture and noise. After that, we improve the method of setting regions of interest (ROI) with the method of edge segmentation and polar transformation. The algorithm has outstanding performance in both computation speed and accuracy. It can solve most of the defect detections including dark point, light point, dark line, etc.

  14. Knowledge of risk factors and early detection methods and practices towards breast cancer among nurses in Indira Gandhi Medical College, Shimla, Himachal Pradesh, India.

    PubMed

    Fotedar, Vikas; Seam, Rajeev K; Gupta, Manoj K; Gupta, Manish; Vats, Siddharth; Verma, Sunita

    2013-01-01

    Breast cancer is an increasing health problem in India. Screening for early detection should lead to a reduction in mortality from the disease. It is known that motivation by nurses influences uptake of screening methods by women. This study aimed to investigate knowledge of breast cancer risk factors and early detection methods and the practice of screening among nurses in Indira Gandhi Medical College, Shimla, Himachal Pradesh. A cross-sectional study was conducted using a self-administered questionnaire to assess the knowledge of breast cancer risk factors, early detection methods and practice of screening methods among 457 nurses working in an Indira Gandhi Medical College, Shimla-H.P. Chi square test, Data was analysed using SPSS version 16. Test of significance used was chi square test. The response rate of the study was 94.9%. The average knowledge of risk factors about breast cancer of the entire population is 49%. 10.5% of nurses had poor knowledge, 25.2% of the nurses had good knowledge, 45% had very good knowledge and 16.3% of the nurses had excellent knowledge about risk factors of breast cancer and early detection methods. The knowledge level was significantly higher among BSC nurses than nurses with Diploma. 54% of participants in this study reportedly practice BSE at least once every year. Less than one-third reported that they had CBE within the past one year. 7% ever had mammogram before this study. Results from this study suggest the frequent continuing medical education programmes on breast cancer at institutional level is desirable.

  15. Anomaly Detection Based on Local Nearest Neighbor Distance Descriptor in Crowded Scenes

    PubMed Central

    Hu, Shiqiang; Zhang, Huanlong; Luo, Lingkun

    2014-01-01

    We propose a novel local nearest neighbor distance (LNND) descriptor for anomaly detection in crowded scenes. Comparing with the commonly used low-level feature descriptors in previous works, LNND descriptor has two major advantages. First, LNND descriptor efficiently incorporates spatial and temporal contextual information around the video event that is important for detecting anomalous interaction among multiple events, while most existing feature descriptors only contain the information of single event. Second, LNND descriptor is a compact representation and its dimensionality is typically much lower than the low-level feature descriptor. Therefore, not only the computation time and storage requirement can be accordingly saved by using LNND descriptor for the anomaly detection method with offline training fashion, but also the negative aspects caused by using high-dimensional feature descriptor can be avoided. We validate the effectiveness of LNND descriptor by conducting extensive experiments on different benchmark datasets. Experimental results show the promising performance of LNND-based method against the state-of-the-art methods. It is worthwhile to notice that the LNND-based approach requires less intermediate processing steps without any subsequent processing such as smoothing but achieves comparable event better performance. PMID:25105164

  16. Detailed Vibration Analysis of Pinion Gear with Time-Frequency Methods

    NASA Technical Reports Server (NTRS)

    Mosher, Marianne; Pryor, Anna H.; Lewicki, David G.

    2003-01-01

    In this paper, the authors show a detailed analysis of the vibration signal from the destructive testing of a spiral bevel gear and pinion pair containing seeded faults. The vibration signal is analyzed in the time domain, frequency domain and with four time-frequency transforms: the Short Time Frequency Transform (STFT), the Wigner-Ville Distribution with the Choi-Williams kernel (WV-CW), the Continuous Wavelet' Transform (CWT) and the Discrete Wavelet Transform (DWT). Vibration data of bevel gear tooth fatigue cracks, under a variety of operating load levels and damage conditions, are analyzed using these methods. A new metric for automatic anomaly detection is developed and can be produced from any systematic numerical representation of the vibration signals. This new metric reveals indications of gear damage with all of the time-frequency transforms, as well as time and frequency representations, on this data set. Analysis with the CWT detects changes in the signal at low torque levels not found with the other transforms. The WV-CW and CWT use considerably more resources than the STFT and the DWT. More testing of the new metric is needed to determine its value for automatic anomaly detection and to develop fault detection methods for the metric.

  17. Development of a large volume injection method using a programmed temperature vaporization injector - gas chromatography hyphenated to ICP-MS for the simultaneous determination of mercury, tin and lead species at ultra-trace levels in natural waters.

    PubMed

    Terán-Baamonde, J; Bouchet, S; Tessier, E; Amouroux, D

    2018-04-27

    The current EU legislation lays down Environmental Quality Standards (EQS) for 45 priority substances in surface waters; among them levels for (organo)metallic species of Hg, Sn and Pb are set between ng L -1 (for Hg and Sn) and μg L -1 (for Pb). To date, only a few analytical methods can reach these very restrictive limits and there is thus a need for comprehensive methods able to analyze these species down to these levels in natural waters. The aim of this work was to develop an online automated pre-concentration method using large volume injections with a Programmed Temperature Vaporization (PTV) injector fitted with a sorbent packed liner coupled to GC-ICP-MS to further improve the detection limits associated to this well-established method. The influence of several parameters such as the PTV transfer temperature and time, carrier gas flow rate and amount of packing material was investigated. Finally, the maximum volume injected through single or multiple injection modes was optimized to obtain the best compromise between chromatographic resolution and sensitivity. After optimization, very satisfactory results in terms of absolute and methodological detection limits were achieved, down to the pg L -1 level for all species studied. The potential of the method was exemplified by determining the concentrations of organometallic compounds in unpolluted river waters samples from the Adour river basin (SW France) and results were compared with conventional (splitless) GC-ICP-MS. The strength of this analytical method lies in the low detection limits reached for the simultaneous analysis of a wide group of organometallic compounds, and the potential to transfer this method to other gas chromatographic applications with inherent lower sensitivity. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Systematic Evaluation of In Vitro and In Vivo Adventitious Virus Assays for the Detection of Viral Contamination of Cell Banks and Biological Products1

    PubMed Central

    Gombold, James; Karakasidis, Stephen; Niksa, Paula; Podczasy, John; Neumann, Kitti; Richardson, James; Sane, Nandini; Johnson-Leva, Renita; Randolph, Valerie; Sadoff, Jerald; Minor, Phillip; Schmidt, Alexander; Duncan, Paul; Sheets, Rebecca L.

    2015-01-01

    Viral vaccines and the cell substrates used to manufacture them are subjected to tests for adventitious agents, including viruses, which might contaminant them. Some of the compendial methods (in vivo and in vitro in cell culture) were established in the mid-20th century. These methods have not been subjected to current assay validation, as new methods would need to be. This study was undertaken to provide insight into the breadth (selectivity) and sensitivity (limit of detection) of the routine methods, two such validation parameters. Sixteen viral stocks were prepared and characterized. These stocks were tested in serial dilutions by the routine methods to establish which viruses were detected by which methods and above what limit of detection. Sixteen out of sixteen viruses were detected in vitro, though one (bovine viral diarrhea virus) required special conditions to detect and another (rubella virus) was detected with low sensitivity. Many were detected at levels below 1 TCID50 or PFU (titers were established on the production cell line in most cases). In contrast, in vivo, only 6/11 viruses were detected, and 4 of these were detected only at amounts one or more logs above 1 TCID50 or PFU. Only influenza virus and vesicular stomatitis virus were detected at lower amounts in vivo than in vitro. Given the call to reduce, refine, or replace (3 R's) the use of animals in product safety testing and the emergence of new technologies for the detection of viruses, a re-examination of the current adventitious virus testing strategies seems warranted. Suggested pathways forward are offered. PMID:24681273

  19. A fluorescence method for detection of DNA and DNA methylation based on graphene oxide and restriction endonuclease HpaII.

    PubMed

    Wei, Wei; Gao, Chunyan; Xiong, Yanxiang; Zhang, Yuanjian; Liu, Songqin; Pu, Yuepu

    2015-01-01

    DNA methylation plays an important role in many biological events and is associated with various diseases. Most traditional methods for detection of DNA methylation are based on the complex and expensive bisulfite method. In this paper, we report a novel fluorescence method to detect DNA and DNA methylation based on graphene oxide (GO) and restriction endonuclease HpaII. The skillfully designed probe DNA labeled with 5-carboxyfluorescein (FAM) and optimized GO concentration keep the probe/target DNA still adsorbed on the GO. After the cleavage action of HpaII the labeled FAM is released from the GO surface and its fluorescence recovers, which could be used to detect DNA in the linear range of 50 pM-50 nM with a detection limit of 43 pM. DNA methylation induced by transmethylase (Mtase) or other chemical reagents prevents HpaII from recognizing and cleaving the specific site; as a result, fluorescence cannot recover. The fluorescence recovery efficiency is closely related to the DNA methylation level, which can be used to detect DNA methylation by comparing it with the fluorescence in the presence of intact target DNA. The method for detection of DNA and DNA methylation is simple, reliable and accurate. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Noise suppression for the differential detection in nuclear magnetic resonance gyroscope

    NASA Astrophysics Data System (ADS)

    Yang, Dan; Zhou, Binquan; Chen, LinLin; Jia, YuChen; Lu, QiLin

    2017-10-01

    The nuclear magnetic resonance gyroscope is based on spin-exchange optical pumping of noble gases to detect and measure the angular velocity of the carrier, but it would be challenging to measure the precession signal of noble gas nuclei directly. To solve the problem, the primary detection method utilizes alkali atoms, the precession of nuclear magnetization modulates the alkali atoms at the Larmor frequency of nuclei, relatively speaking, and it is easier to detect the precession signal of alkali atoms. The precession frequency of alkali atoms is detected by the rotation angle of linearly polarized probe light; and differential detection method is commonly used in NMRG in order to detect the linearly polarized light rotation angle. Thus, the detection accuracy of differential detection system will affect the sensitivity of the NMRG. For the purpose of further improvement of the sensitivity level of the NMRG, this paper focuses on the aspects of signal detection, and aims to do an error analysis as well as an experimental research of the linearly light rotation angle detection. Through the theoretical analysis and the experimental illustration, we found that the extinction ratio σ2 and DC bias are the factors that will produce detective noise in the differential detection method.

  1. Epileptic Seizure Detection Based on Time-Frequency Images of EEG Signals using Gaussian Mixture Model and Gray Level Co-Occurrence Matrix Features.

    PubMed

    Li, Yang; Cui, Weigang; Luo, Meilin; Li, Ke; Wang, Lina

    2018-01-25

    The electroencephalogram (EEG) signal analysis is a valuable tool in the evaluation of neurological disorders, which is commonly used for the diagnosis of epileptic seizures. This paper presents a novel automatic EEG signal classification method for epileptic seizure detection. The proposed method first employs a continuous wavelet transform (CWT) method for obtaining the time-frequency images (TFI) of EEG signals. The processed EEG signals are then decomposed into five sub-band frequency components of clinical interest since these sub-band frequency components indicate much better discriminative characteristics. Both Gaussian Mixture Model (GMM) features and Gray Level Co-occurrence Matrix (GLCM) descriptors are then extracted from these sub-band TFI. Additionally, in order to improve classification accuracy, a compact feature selection method by combining the ReliefF and the support vector machine-based recursive feature elimination (RFE-SVM) algorithm is adopted to select the most discriminative feature subset, which is an input to the SVM with the radial basis function (RBF) for classifying epileptic seizure EEG signals. The experimental results from a publicly available benchmark database demonstrate that the proposed approach provides better classification accuracy than the recently proposed methods in the literature, indicating the effectiveness of the proposed method in the detection of epileptic seizures.

  2. On precise phase difference measurement approach using border stability of detection resolution.

    PubMed

    Bai, Lina; Su, Xin; Zhou, Wei; Ou, Xiaojuan

    2015-01-01

    For the precise phase difference measurement, this paper develops an improved dual phase coincidence detection method. The measurement resolution of the digital phase coincidence detection circuits is always limited, for example, only at the nanosecond level. This paper reveals a new way to improve the phase difference measurement precision by using the border stability of the circuit detection fuzzy areas. When a common oscillator signal is used to detect the phase coincidence with the two comparison signals, there will be two detection fuzzy areas for the reason of finite detection resolution surrounding the strict phase coincidence. Border stability of fuzzy areas and the fluctuation difference of the two fuzzy areas can be even finer than the picoseconds level. It is shown that the system resolution obtained only depends on the stability of the circuit measurement resolution which is much better than the measurement device resolution itself.

  3. SpeCond: a method to detect condition-specific gene expression

    PubMed Central

    2011-01-01

    Transcriptomic studies routinely measure expression levels across numerous conditions. These datasets allow identification of genes that are specifically expressed in a small number of conditions. However, there are currently no statistically robust methods for identifying such genes. Here we present SpeCond, a method to detect condition-specific genes that outperforms alternative approaches. We apply the method to a dataset of 32 human tissues to determine 2,673 specifically expressed genes. An implementation of SpeCond is freely available as a Bioconductor package at http://www.bioconductor.org/packages/release/bioc/html/SpeCond.html. PMID:22008066

  4. A Simple and Direct LC-MS Method for Determination of Genotoxic Impurity Hydroxylamine in Pharmaceutical compounds.

    PubMed

    Kumar, Thangarathinam; Ramya, Mohandass; Srinivasan, Viswanathan; Xavier, N

    2017-08-01

    Hydroxylamine is a known genotoxic impurity compound that needs to be controlled down to ppm level in pharmaceutical processes. It is difficult to detect using conventional analytical techniques due to its physio-chemical properties like lack of chromophore, low molecular weight, absence of carbon atom and high polarity. In addition to that, analysis of the pharmaceutical samples encounters considerable obstruction from matrix components that greatly overshadow the response of hydroxylamine. This study describes a simple, sensitive and direct Liquid Chromatographic-Mass Spectrometric method (LC-MS) for detection of hydroxylamine in pharmaceutical compounds. The LC-MS method was detected up to 0.008 ppm of hydroxylamine with S/N > 3.0 and quantified up to 0.025 ppm of hydroxylamine with S/N ratio >10.0. This validated method can be applied as a generic method to detect the hydroxylamine for pharmaceutical process control and drug substance release. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Systems and methods for detecting an image of an object by use of an X-ray beam having a polychromatic distribution

    DOEpatents

    Parham, Christopher; Zhong, Zhong; Pisano, Etta; Connor, Dean; Chapman, Leroy D.

    2010-06-22

    Systems and methods for detecting an image of an object using an X-ray beam having a polychromatic energy distribution are disclosed. According to one aspect, a method can include detecting an image of an object. The method can include generating a first X-ray beam having a polychromatic energy distribution. Further, the method can include positioning a single monochromator crystal in a predetermined position to directly intercept the first X-ray beam such that a second X-ray beam having a predetermined energy level is produced. Further, an object can be positioned in the path of the second X-ray beam for transmission of the second X-ray beam through the object and emission from the object as a transmitted X-ray beam. The transmitted X-ray beam can be directed at an angle of incidence upon a crystal analyzer. Further, an image of the object can be detected from a beam diffracted from the analyzer crystal.

  6. The Application of Time-Frequency Methods to HUMS

    NASA Technical Reports Server (NTRS)

    Pryor, Anna H.; Mosher, Marianne; Lewicki, David G.; Norvig, Peter (Technical Monitor)

    2001-01-01

    This paper reports the study of four time-frequency transforms applied to vibration signals and presents a new metric for comparing them for fault detection. The four methods to be described and compared are the Short Time Frequency Transform (STFT), the Choi-Williams Distribution (WV-CW), the Continuous Wavelet Transform (CWT) and the Discrete Wavelet Transform (DWT). Vibration data of bevel gear tooth fatigue cracks, under a variety of operating load levels, are analyzed using these methods. The new metric for automatic fault detection is developed and can be produced from any systematic numerical representation of the vibration signals. This new metric reveals indications of gear damage with all of the methods on this data set. Analysis with the CWT detects mechanical problems with the test rig not found with the other transforms. The WV-CW and CWT use considerably more resources than the STFT and the DWT. More testing of the new metric is needed to determine its value for automatic fault detection and to develop methods of setting the threshold for the metric.

  7. Near-infrared microscopic methods for the detection and quantification of processed by-products of animal origin

    NASA Astrophysics Data System (ADS)

    Abbas, O.; Fernández Pierna, J. A.; Dardenne, P.; Baeten, V.

    2010-04-01

    Since the BSE crisis, researches concern mainly the detection, identification, and quantification of meat and bone meal with an important focus on the development of new analytical methods. Microscopic based spectroscopy methods (NIR microscopy - NIRM or/and NIR hyperspectral imaging) have been proposed as complementary methods to the official method; the optical microscopy. NIR spectroscopy offers the advantage of being rapid, accurate and independent of human analyst skills. The combination of an NIR detector and a microscope or a camera allows the collection of high quality spectra for small feed particles having a size larger than 50 μm. Several studies undertaken have demonstrated the clear potential of NIR microscopic methods for the detection of animal particles in both raw and sediment fractions. Samples are sieved and only the gross fraction (superior than 250 μm) is investigated. Proposed methodologies have been developed to assure, with an acceptable level of confidence (95%), the detection of at least one animal particle when a feed sample is adulterated at a level of 0.1%. NIRM and NIR hyperspectral imaging are running under accreditation ISO 17025 since 2005 at CRA-W. A quantitative NIRM approach has been developed in order to fulfill the new requirements of the European commission policies. The capacities of NIRM method have been improved; only the raw fraction is analyzed, both the gross and the fine fractions of the samples are considered, and the acquisition parameters are optimized (the aperture, the gap, and the composition of the animal feed). A mapping method for a faster collection of spectra is also developed. The aim of this work is to show the new advances in the analytical methods developed in the frame of the feed ban applied in Europe.

  8. Thermographic techniques and adapted algorithms for automatic detection of foreign bodies in food

    NASA Astrophysics Data System (ADS)

    Meinlschmidt, Peter; Maergner, Volker

    2003-04-01

    At the moment foreign substances in food are detected mainly by using mechanical and optical methods as well as ultrasonic technique and than they are removed from the further process. These techniques detect a large portion of the foreign substances due to their different mass (mechanical sieving), their different colour (optical method) and their different surface density (ultrasonic detection). Despite the numerous different methods a considerable portion of the foreign substances remain undetected. In order to recognise materials still undetected, a complementary detection method would be desirable removing the foreign substances not registered by the a.m. methods from the production process. In a project with 13 partner from the food industry, the Fraunhofer - Institut für Holzforschung (WKI) and the Technische Unsiversität are trying to adapt thermography for the detection of foreign bodies in the food industry. After the initial tests turned out to be very promising for the differentiation of food stuffs and foreign substances, more and detailed investigation were carried out to develop suitable algorithms for automatic detection of foreign bodies. In order to achieve -besides the mere visual detection of foreign substances- also an automatic detection under production conditions, numerous experiences in image processing and pattern recognition are exploited. Results for the detection of foreign bodies will be presented at the conference showing the different advantages and disadvantages of using grey - level, statistical and morphological image processing techniques.

  9. Updated Overview of Infrared Spectroscopy Methods for Detecting Mycotoxins on Cereals (Corn, Wheat, and Barley)

    PubMed Central

    2018-01-01

    Each year, mycotoxins cause economic losses of several billion US dollars worldwide. Consequently, methods must be developed, for producers and cereal manufacturers, to detect these toxins and to comply with regulations. Chromatographic reference methods are time consuming and costly. Thus, alternative methods such as infrared spectroscopy are being increasingly developed to provide simple, rapid, and nondestructive methods to detect mycotoxins. This article reviews research conducted over the last eight years into the use of near-infrared and mid-infrared spectroscopy to monitor mycotoxins in corn, wheat, and barley. More specifically, we focus on the Fusarium species and on the main fusariotoxins of deoxynivalenol, zearalenone, and fumonisin B1 and B2. Quantification models are insufficiently precise to satisfy the legal requirements. Sorting models with cutoff levels are the most promising applications. PMID:29320435

  10. Updated Overview of Infrared Spectroscopy Methods for Detecting Mycotoxins on Cereals (Corn, Wheat, and Barley).

    PubMed

    Levasseur-Garcia, Cecile

    2018-01-10

    Each year, mycotoxins cause economic losses of several billion US dollars worldwide. Consequently, methods must be developed, for producers and cereal manufacturers, to detect these toxins and to comply with regulations. Chromatographic reference methods are time consuming and costly. Thus, alternative methods such as infrared spectroscopy are being increasingly developed to provide simple, rapid, and nondestructive methods to detect mycotoxins. This article reviews research conducted over the last eight years into the use of near-infrared and mid-infrared spectroscopy to monitor mycotoxins in corn, wheat, and barley. More specifically, we focus on the Fusarium species and on the main fusariotoxins of deoxynivalenol, zearalenone, and fumonisin B1 and B2. Quantification models are insufficiently precise to satisfy the legal requirements. Sorting models with cutoff levels are the most promising applications.

  11. Linguistic Summarization of Video for Fall Detection Using Voxel Person and Fuzzy Logic

    PubMed Central

    Anderson, Derek; Luke, Robert H.; Keller, James M.; Skubic, Marjorie; Rantz, Marilyn; Aud, Myra

    2009-01-01

    In this paper, we present a method for recognizing human activity from linguistic summarizations of temporal fuzzy inference curves representing the states of a three-dimensional object called voxel person. A hierarchy of fuzzy logic is used, where the output from each level is summarized and fed into the next level. We present a two level model for fall detection. The first level infers the states of the person at each image. The second level operates on linguistic summarizations of voxel person’s states and inference regarding activity is performed. The rules used for fall detection were designed under the supervision of nurses to ensure that they reflect the manner in which elders perform these activities. The proposed framework is extremely flexible. Rules can be modified, added, or removed, allowing for per-resident customization based on knowledge about their cognitive and physical ability. PMID:20046216

  12. Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors.

    PubMed

    Zhang, Chongxing; Dong, Ming; Ren, Ming; Huang, Wenguang; Zhou, Jierui; Gao, Xuze; Albarracín, Ricardo

    2018-02-11

    Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of metal-enclosed switchgear. The transient earth voltage method, an effective non-intrusive method, has substantial engineering application value for estimating the insulation condition of switchgear. However, the practical application effectiveness of TEV detection is not satisfactory because of the lack of a TEV detection application method, i.e., a method with sufficient technical cognition and analysis. This paper proposes an innovative online PD detection system and a corresponding application strategy based on an intelligent feedback distributed TEV wireless sensor network, consisting of sensing, communication, and diagnosis layers. In the proposed system, the TEV signal or status data are wirelessly transmitted to the terminal following low-energy signal preprocessing and acquisition by TEV sensors. Then, a central server analyzes the correlation of the uploaded data and gives a fault warning level according to the quantity, trend, parallel analysis, and phase resolved partial discharge pattern recognition. In this way, a TEV detection system and strategy with distributed acquisition, unitized fault warning, and centralized diagnosis is realized. The proposed system has positive significance for reducing the fault rate of medium voltage switchgear and improving its operation and maintenance level.

  13. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of organophosphate pesticides in filtered water by gas chromatography with flame photometric detection

    USGS Publications Warehouse

    Jha, Virendra K.; Wydoski, Duane S.

    2002-01-01

    A method for the isolation of 20 parent organophosphate pesticides and 5 pesticide degradates from filtered natural-water samples is described. Seven of these compounds are reported permanently with an estimated concentration because of performance issues. Water samples are filtered to remove suspended particulate matter, and then 1 liter of filtrate is pumped through disposable solid-phase extraction columns that contain octadecyl-bonded porous silica to extract the compounds. The C-18 columns are dried with nitrogen gas, and method compounds are eluted from the columns with ethyl acetate. The extract is analyzed by dual capillary-column gas chromatography with flame photometric detection. Single-operator method detection limits in all three water-matrix samples ranged from 0.004 to 0.012 microgram per liter. Method performance was validated by spiking all compounds into three different matrices at three different concentrations. Eight replicates were analyzed at each concentration level in each matrix. Mean recoveries of method compounds spiked in surface-water samples ranged from 39 to 149 percent and those in ground-water samples ranged from 40 to 124 percent for all pesticides except dimethoate. Mean recoveries of method compounds spiked in reagent-water samples ranged from 41 to 119 percent for all pesticides except dimethoate. Dimethoate exhibited reduced recoveries (mean of 43 percent in low- and medium-concentration level spiked samples and 20 percent in high-concentration level spiked samples) in all matrices because of incomplete collection on the C-18 column. As a result, concen-trations of dimethoate and six other compounds (based on performance issues) in samples are reported in this method with an estimated remark code.

  14. A Multi-Level Decision Fusion Strategy for Condition Based Maintenance of Composite Structures

    PubMed Central

    Sharif Khodaei, Zahra; Aliabadi, M.H.

    2016-01-01

    In this work, a multi-level decision fusion strategy is proposed which weighs the Value of Information (VoI) against the intended functions of a Structural Health Monitoring (SHM) system. This paper presents a multi-level approach for three different maintenance strategies in which the performance of the SHM systems is evaluated against its intended functions. Level 1 diagnosis results in damage existence with minimum sensors covering a large area by finding the maximum energy difference for the guided waves propagating in pristine structure and the post-impact state; Level 2 diagnosis provides damage detection and approximate localization using an approach based on Electro-Mechanical Impedance (EMI) measures, while Level 3 characterizes damage (exact location and size) in addition to its detection by utilising a Weighted Energy Arrival Method (WEAM). The proposed multi-level strategy is verified and validated experimentally by detection of Barely Visible Impact Damage (BVID) on a curved composite fuselage panel. PMID:28773910

  15. Detection of telomerase on upconversion nanoparticle modified cellulose paper.

    PubMed

    Wang, Faming; Li, Wen; Wang, Jiasi; Ren, Jinsong; Qu, Xiaogang

    2015-07-25

    Herein we report a convenient and sensitive method for the detection of telomerase activity based on upconversion nanoparticle (UCNP) modified cellulose paper. Compared with many solution-phase systems, this paper chip is more stable and easily stores the test results. What's more, the low background fluorescence of the UCNPs increases the sensitivity of this method, and the low telomerase levels in different cell lines can clearly be discriminated by the naked eye.

  16. Scombroid poisoning: a review.

    PubMed

    Hungerford, James M

    2010-08-15

    Scombroid poisoning, also called histamine fish poisoning, is an allergy-like form of food poisoning that continues to be a major problem in seafood safety. The exact role of histamine in scombroid poisoning is not straightforward. Deviations from the expected dose-response have led to the advancement of various possible mechanisms of toxicity, none of them proven. Histamine action levels are used in regulation until more is known about the mechanism of scombroid poisoning. Scombroid poisoning and histamine are correlated but complicated. Victims of scombroid poisoning respond well to antihistamines, and chemical analyses of fish implicated in scombroid poisoning generally reveal elevated levels of histamine. Scombroid poisoning is unique among the seafood toxins since it results from product mishandling rather than contamination from other trophic levels. Inadequate cooling following harvest promotes bacterial histamine production, and can result in outbreaks of scombroid poisoning. Fish with high levels of free histidine, the enzyme substrate converted to histamine by bacterial histidine decarboxylase, are those most often implicated in scombroid poisoning. Laboratory methods and screening methods for detecting histamine are available in abundance, but need to be compared and validated to harmonize testing. Successful field testing, including dockside or on-board testing needed to augment HACCP efforts will have to integrate rapid and simplified detection methods with simplified and rapid sampling and extraction. Otherwise, time-consuming sample preparation reduces the impact of gains in detection speed on the overall analysis time. Published by Elsevier Ltd.

  17. Circulating Mycobacterium bovis peptides and host response proteins as biomarkers for unambiguous detection of subclinical infection

    USDA-ARS?s Scientific Manuscript database

    Background: Bovine tuberculosis remains one of the most damaging zoonotic diseases. A critical need exists for rapid and inexpensive diagnostics capable of detecting and differentiating M. bovis infection from other pathogenic and environmental mycobacteria at multiple surveillance levels. Method...

  18. Cost-Effectiveness Analysis of Three Leprosy Case Detection Methods in Northern Nigeria

    PubMed Central

    Ezenduka, Charles; Post, Erik; John, Steven; Suraj, Abdulkarim; Namadi, Abdulahi; Onwujekwe, Obinna

    2012-01-01

    Background Despite several leprosy control measures in Nigeria, child proportion and disability grade 2 cases remain high while new cases have not significantly reduced, suggesting continuous spread of the disease. Hence, there is the need to review detection methods to enhance identification of early cases for effective control and prevention of permanent disability. This study evaluated the cost-effectiveness of three leprosy case detection methods in Northern Nigeria to identify the most cost-effective approach for detection of leprosy. Methods A cross-sectional study was carried out to evaluate the additional benefits of using several case detection methods in addition to routine practice in two north-eastern states of Nigeria. Primary and secondary data were collected from routine practice records and the Nigerian Tuberculosis and Leprosy Control Programme of 2009. The methods evaluated were Rapid Village Survey (RVS), Household Contact Examination (HCE) and Traditional Healers incentive method (TH). Effectiveness was measured as number of new leprosy cases detected and cost-effectiveness was expressed as cost per case detected. Costs were measured from both providers' and patients' perspectives. Additional costs and effects of each method were estimated by comparing each method against routine practise and expressed as incremental cost-effectiveness ratio (ICER). All costs were converted to the U.S. dollar at the 2010 exchange rate. Univariate sensitivity analysis was used to evaluate uncertainties around the ICER. Results The ICER for HCE was $142 per additional case detected at all contact levels and it was the most cost-effective method. At ICER of $194 per additional case detected, THs method detected more cases at a lower cost than the RVS, which was not cost-effective at $313 per additional case detected. Sensitivity analysis showed that varying the proportion of shared costs and subsistent wage for valuing unpaid time did not significantly change the results. Conclusion Complementing routine practice with household contact examination is the most cost-effective approach to identify new leprosy cases and we recommend that, depending on acceptability and feasibility, this intervention is introduced for improved case detection in Northern Nigeria. PMID:23029580

  19. Online monitoring of oil film using electrical capacitance tomography and level set method.

    PubMed

    Xue, Q; Sun, B Y; Cui, Z Q; Ma, M; Wang, H X

    2015-08-01

    In the application of oil-air lubrication system, electrical capacitance tomography (ECT) provides a promising way for monitoring oil film in the pipelines by reconstructing cross sectional oil distributions in real time. While in the case of small diameter pipe and thin oil film, the thickness of the oil film is hard to be observed visually since the interface of oil and air is not obvious in the reconstructed images. And the existence of artifacts in the reconstructions has seriously influenced the effectiveness of image segmentation techniques such as level set method. Besides, level set method is also unavailable for online monitoring due to its low computation speed. To address these problems, a modified level set method is developed: a distance regularized level set evolution formulation is extended to image two-phase flow online using an ECT system, a narrowband image filter is defined to eliminate the influence of artifacts, and considering the continuity of the oil distribution variation, the detected oil-air interface of a former image can be used as the initial contour for the detection of the subsequent frame; thus, the propagation from the initial contour to the boundary can be greatly accelerated, making it possible for real time tracking. To testify the feasibility of the proposed method, an oil-air lubrication facility with 4 mm inner diameter pipe is measured in normal operation using an 8-electrode ECT system. Both simulation and experiment results indicate that the modified level set method is capable of visualizing the oil-air interface accurately online.

  20. Online monitoring of oil film using electrical capacitance tomography and level set method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xue, Q., E-mail: xueqian@tju.edu.cn; Ma, M.; Sun, B. Y.

    2015-08-15

    In the application of oil-air lubrication system, electrical capacitance tomography (ECT) provides a promising way for monitoring oil film in the pipelines by reconstructing cross sectional oil distributions in real time. While in the case of small diameter pipe and thin oil film, the thickness of the oil film is hard to be observed visually since the interface of oil and air is not obvious in the reconstructed images. And the existence of artifacts in the reconstructions has seriously influenced the effectiveness of image segmentation techniques such as level set method. Besides, level set method is also unavailable for onlinemore » monitoring due to its low computation speed. To address these problems, a modified level set method is developed: a distance regularized level set evolution formulation is extended to image two-phase flow online using an ECT system, a narrowband image filter is defined to eliminate the influence of artifacts, and considering the continuity of the oil distribution variation, the detected oil-air interface of a former image can be used as the initial contour for the detection of the subsequent frame; thus, the propagation from the initial contour to the boundary can be greatly accelerated, making it possible for real time tracking. To testify the feasibility of the proposed method, an oil-air lubrication facility with 4 mm inner diameter pipe is measured in normal operation using an 8-electrode ECT system. Both simulation and experiment results indicate that the modified level set method is capable of visualizing the oil-air interface accurately online.« less

  1. Magnetic bead-quantum dot assay for detection of a biomarker for traumatic brain injury

    NASA Astrophysics Data System (ADS)

    Kim, Chloe; Searson, Peter C.

    2015-10-01

    Current diagnostic methods for traumatic brain injury (TBI), which accounts for 15% of all emergency room visits, are limited to neuroimaging modalities. The challenges of accurate diagnosis and monitoring of TBI have created the need for a simple and sensitive blood test to detect brain-specific biomarkers. Here we report on an assay for detection of S100B, a putative biomarker for TBI, using antibody-conjugated magnetic beads for capture of the protein, and antibody-conjugated quantum dots for optical detection. From Western Blot, we show efficient antigen capture and concentration by the magnetic beads. Using magnetic bead capture and quantum dot detection in serum samples, we show a wide detection range and detection limit below the clinical cut-off level.Current diagnostic methods for traumatic brain injury (TBI), which accounts for 15% of all emergency room visits, are limited to neuroimaging modalities. The challenges of accurate diagnosis and monitoring of TBI have created the need for a simple and sensitive blood test to detect brain-specific biomarkers. Here we report on an assay for detection of S100B, a putative biomarker for TBI, using antibody-conjugated magnetic beads for capture of the protein, and antibody-conjugated quantum dots for optical detection. From Western Blot, we show efficient antigen capture and concentration by the magnetic beads. Using magnetic bead capture and quantum dot detection in serum samples, we show a wide detection range and detection limit below the clinical cut-off level. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr05608j

  2. [The development of the methods for the determination of nickel and its urine levels by inversion voltamperometry].

    PubMed

    Antoshina, L I; Pavlovskaia, N A

    1999-01-01

    The authors created a method detecting nickel through inversion voltamperometry by Russian analyzer CVA = 1BM. The method is diagnostic in hygienic, clinical and toxicologic studies for measuring quantity of nickel that enters human body during occupational activities.

  3. Evaluation of an alternative extraction procedure for enterotoxin determination in dairy products.

    PubMed

    Meyrand, A; Atrache, V; Bavai, C; Montet, M P; Vernozy-Rozand, C

    1999-06-01

    A concentration protocol based on trichloroacetic acid precipitation was evaluated and compared with the reference method using dialysis concentration. Different quantities of purified staphylococcal enterotoxins were added to pasteurized Camembert-type cheeses. Detection of enterotoxins in these cheeses was performed using an automated detection system. Raw goat milk Camembert-type cheeses involved in a staphylococcal food poisoning were also tested. Both enterotoxin extraction methods allowed detection of the lowest enterotoxin concentration level used in this study (0.5 ng g-1). Compared with the dialysis concentration method, TCA precipitation of staphylococcal enterotoxins was 'user-friendly' and less time-consuming. These results suggest that TCA precipitation is a rapid (1 h), simple and reliable method of extracting enterotoxin from food which gives excellent recovery from dairy products.

  4. In Situ Detection of MicroRNA Expression with RNAscope Probes.

    PubMed

    Yin, Viravuth P

    2018-01-01

    Elucidating the spatial resolution of gene transcripts provides important insight into potential gene function. MicroRNAs are short, singled-stranded noncoding RNAs that control gene expression through base-pair complementarity with target mRNAs in the 3' untranslated region (UTR) and inhibiting protein expression. However, given their small size of ~22- to 24-nt and low expression levels, standard in situ hybridization detection methods are not amendable for microRNA spatial resolution. Here, I describe a technique that employs RNAscope probe design and propriety amplification technology that provides simultaneous single molecule detection of individual microRNA and its target gene. This method allows for rapid and sensitive detection of noncoding RNA transcripts in frozen tissue sections.

  5. A Method of Character Detection and Segmentation for Highway Guide Signs

    NASA Astrophysics Data System (ADS)

    Xu, Jiawei; Zhang, Chongyang

    2018-01-01

    In this paper, a method of character detection and segmentation for highway signs in China is proposed. It consists of four steps. Firstly, the highway sign area is detectedby colour and geometric features, andthe possible character region is obtained by multi-level projection strategy. Secondly, pseudo target character region is removed by local binary patterns (LBP) feature. Thirdly, convolutional neural network (CNN)is used to classify target regions. Finally, adaptive projection strategies are used to segment characters strings. Experimental results indicate that the proposed method achieves new state-of-the-art results.

  6. Method for the determination of catechin and epicatechin enantiomers in cocoa-based ingredients and products by high-performance liquid chromatography: single-laboratory validation.

    PubMed

    Machonis, Philip R; Jones, Matthew A; Schaneberg, Brian T; Kwik-Uribe, Catherine L

    2012-01-01

    A single-laboratory validation study was performed for an HPLC method to identify and quantify the flavanol enantiomers (+)- and (-)-epicatechin and (+)- and (-)-catechin in cocoa-based ingredients and products. These compounds were eluted isocratically with an ammonium acetate-methanol mobile phase applied to a modified beta-cyclodextrin chiral stationary phase and detected using fluorescence. Spike recovery experiments using appropriate matrix blanks, along with cocoa extract, cocoa powder, and dark chocolate, were used to evaluate accuracy, repeatability, specificity, LOD, LOQ, and linearity of the method as performed by a single analyst on multiple days. In all samples analyzed, (-)-epicatechin was the predominant flavanol and represented 68-91% of the total monomeric flavanols detected. For the cocoa-based products, within-day (intraday) precision for (-)-epicatechin was between 1.46-3.22%, for (+)-catechin between 3.66-6.90%, and for (-)-catechin between 1.69-6.89%; (+)-epicatechin was not detected in these samples. Recoveries for the three sample types investigated ranged from 82.2 to 102.1% at the 50% spiking level, 83.7 to 102.0% at the 100% spiking level, and 80.4 to 101.1% at the 200% spiking level. Based on performance results, this method may be suitable for routine laboratory use in analysis of cocoa-based ingredients and products.

  7. Rapid concentration and sensitive detection of hookworm ova from wastewater matrices using a real-time PCR method.

    PubMed

    Gyawali, P; Sidhu, J P S; Ahmed, W; Jagals, P; Toze, S

    2015-12-01

    The risk of human hookworm infections from land application of wastewater matrices could be high in regions with high hookworm prevalence. A rapid, sensitive and specific hookworm detection method from wastewater matrices is required in order to assess human health risks. Currently available methods used to identify hookworm ova to the species level are time consuming and lack accuracy. In this study, a real-time PCR method was developed for the rapid, sensitive and specific detection of canine hookworm (Ancylostoma caninum) ova from wastewater matrices. A. caninum was chosen because of its morphological similarity to the human hookworm (Ancylostoma duodenale and Necator americanus). The newly developed PCR method has high detection sensitivity with the ability to detect less than one A. caninum ova from 1 L of secondary treated wastewater at the mean threshold cycle (CT) values ranging from 30.1 to 34.3. The method is also able to detect four A. caninum ova from 1 L of raw wastewater and from ∼4 g of treated sludge with mean CT values ranging from 35.6 to 39.8 and 39.8 to 39.9, respectively. The better detection sensitivity obtained for secondary treated wastewater compared to raw wastewater and sludge samples could be attributed to sample turbidity. The proposed method appears to be rapid, sensitive and specific compared to traditional methods and has potential to aid in the public health risk assessment associated with land application of wastewater matrices. Furthermore, the method can be adapted to detect other helminth ova of interest from wastewater matrices. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  8. Comparison of Real-Time PCR, Reverse Transcriptase Real-Time PCR, Loop-Mediated Isothermal Amplification, and the FDA Conventional Microbiological Method for the Detection of Salmonella spp. in Produce ▿ †

    PubMed Central

    Zhang, Guodong; Brown, Eric W.; González-Escalona, Narjol

    2011-01-01

    Contamination of foods, especially produce, with Salmonella spp. is a major concern for public health. Several methods are available for the detection of Salmonella in produce, but their relative efficiency for detecting Salmonella in commonly consumed vegetables, often associated with outbreaks of food poisoning, needs to be confirmed. In this study, the effectiveness of three molecular methods for detection of Salmonella in six produce matrices was evaluated and compared to the FDA microbiological detection method. Samples of cilantro (coriander leaves), lettuce, parsley, spinach, tomato, and jalapeno pepper were inoculated with Salmonella serovars at two different levels (105 and <101 CFU/25 g of produce). The inoculated produce was assayed by the FDA Salmonella culture method (Bacteriological Analytical Manual) and by three molecular methods: quantitative real-time PCR (qPCR), quantitative reverse transcriptase real-time PCR (RT-qPCR), and loop-mediated isothermal amplification (LAMP). Comparable results were obtained by these four methods, which all detected as little as 2 CFU of Salmonella cells/25 g of produce. All control samples (not inoculated) were negative by the four methods. RT-qPCR detects only live Salmonella cells, obviating the danger of false-positive results from nonviable cells. False negatives (inhibition of either qPCR or RT-qPCR) were avoided by the use of either a DNA or an RNA amplification internal control (IAC). Compared to the conventional culture method, the qPCR, RT-qPCR, and LAMP assays allowed faster and equally accurate detection of Salmonella spp. in six high-risk produce commodities. PMID:21803916

  9. I Environmental DNA sampling is more sensitive than a traditional survey technique for detecting an aquatic invader.

    PubMed

    Smart, Adam S; Tingley, Reid; Weeks, Andrew R; van Rooyen, Anthony R; McCarthy, Michael A

    2015-10-01

    Effective management of alien species requires detecting populations in the early stages of invasion. Environmental DNA (eDNA) sampling can detect aquatic species at relatively low densities, but few studies have directly compared detection probabilities of eDNA sampling with those of traditional sampling methods. We compare the ability of a traditional sampling technique (bottle trapping) and eDNA to detect a recently established invader, the smooth newt Lissotriton vulgaris vulgaris, at seven field sites in Melbourne, Australia. Over a four-month period, per-trap detection probabilities ranged from 0.01 to 0.26 among sites where L. v. vulgaris was detected, whereas per-sample eDNA estimates were much higher (0.29-1.0). Detection probabilities of both methods varied temporally (across days and months), but temporal variation appeared to be uncorrelated between methods. Only estimates of spatial variation were strongly correlated across the two sampling techniques. Environmental variables (water depth, rainfall, ambient temperature) were not clearly correlated with detection probabilities estimated via trapping, whereas eDNA detection probabilities were negatively correlated with water depth, possibly reflecting higher eDNA concentrations at lower water levels. Our findings demonstrate that eDNA sampling can be an order of magnitude more sensitive than traditional methods, and illustrate that traditional- and eDNA-based surveys can provide independent information on species distributions when occupancy surveys are conducted over short timescales.

  10. A microfluidic approach for hemoglobin detection in whole blood

    NASA Astrophysics Data System (ADS)

    Taparia, Nikita; Platten, Kimsey C.; Anderson, Kristin B.; Sniadecki, Nathan J.

    2017-10-01

    Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  11. Development of a Sensitive and Specific Polyclonal Antibody for Serological Detection of Clavibacter michiganensis subsp. sepedonicus

    PubMed Central

    Przewodowska, Agnieszka

    2017-01-01

    The quarantine bacterium Clavibacter michiganensis subsp. sepedonicus (Cms) causes bacterial ring rot (BRR) in potato but is difficult to detect, hampering the diagnosis of this disease. ELISA immunoassays have not been widely used to detect Cms because commercially available anti-Cms antibodies detect mainly EPS-producing bacteria and can fail to detect strains that do not produce EPS. In the current study, we developed a new type of polyclonal antibody that specifically detects Clavibacter michiganensis subsp. sepedonicus bacteria irrespective of their EPS level. We first found that the presence of bacterial EPS precluded quantitative measurement of bacteria by currently available immunoenzymatic methods, but that washing Cms cells with acidic and basic buffers to remove EPS before analysis successfully standardized ELISA results. We used a mix of three strains of Cms with diverse EPS levels to generate antigen for production of antibodies recognizing Cms cells with and without an EPS layer (IgG-EPS and IgG-N-EPS, respectively). The resulting IgG-N-EPS recognized almost all Cms strains tested in this work regardless of their mucoidal level. The availability of this new antibody renders immunological diagnostics of Cms more sensitive and reliable, as our newly developed antibodies can be used in many type of immunoassays. This work represents an important step forward in efforts to diagnose and prevent the spread of BRR, and the methods and solutions developed in this work are covered by six Polish, one European and one US patents. PMID:28068400

  12. Impact of Network Activity Levels on the Performance of Passive Network Service Dependency Discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carroll, Thomas E.; Chikkagoudar, Satish; Arthur-Durett, Kristine M.

    Network services often do not operate alone, but instead, depend on other services distributed throughout a network to correctly function. If a service fails, is disrupted, or degraded, it is likely to impair other services. The web of dependencies can be surprisingly complex---especially within a large enterprise network---and evolve with time. Acquiring, maintaining, and understanding dependency knowledge is critical for many network management and cyber defense activities. While automation can improve situation awareness for network operators and cyber practitioners, poor detection accuracy reduces their confidence and can complicate their roles. In this paper we rigorously study the effects of networkmore » activity levels on the detection accuracy of passive network-based service dependency discovery methods. The accuracy of all except for one method was inversely proportional to network activity levels. Our proposed cross correlation method was particularly robust to the influence of network activity. The proposed experimental treatment will further advance a more scientific evaluation of methods and provide the ability to determine their operational boundaries.« less

  13. Evaluation of volatile organic compound (VOC) blank data and application of study reporting levels to groundwater data collected for the California GAMA Priority Basin Project, May 2004 through September 2010

    USGS Publications Warehouse

    Fram, Miranda S.; Olsen, Lisa D.; Belitz, Kenneth

    2012-01-01

    Volatile organic compounds (VOCs) were analyzed in quality-control samples collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Program Priority Basin Project. From May 2004 through September 2010, a total of 2,026 groundwater samples, 211 field blanks, and 109 source-solution blanks were collected and analyzed for concentrations of 85 VOCs. Results from analyses of these field and source-solution blanks and of 2,411 laboratory instrument blanks during the same time period were used to assess the quality of data for the 2,026 groundwater samples. Eighteen VOCs were detected in field blanks or source-solution blanks: acetone, benzene, bromodichloromethane, 2-butanone, carbon disulfide, chloroform, 1,1-dichloroethene, dichloromethane, ethylbenzene, tetrachloroethene, styrene, tetrahydrofuran, toluene, trichloroethene, trichlorofluoromethane, 1,2,4-trimethylbenzene, m- and p-xylenes, and o-xylene. The objective of the evaluation of the VOC-blank data was to determine if study reporting levels (SRLs) were needed for any of the VOCs detected in blanks to ensure the quality of the data from groundwater samples. An SRL is equivalent to a raised reporting level that is used in place of the reporting level used by the analyzing laboratory [long‑term method detection level (LT-MDL) or laboratory reporting level (LRL)] to reduce the probability of reporting false-positive detections. Evaluation of VOC-blank data was done in three stages: (1) identification of a set of representative quality‑control field blanks (QCFBs) to be used for calculation of SRLs and identification of VOCs amenable to the SRL approach, (2) evaluation of potential sources of contamination to blanks and groundwater samples by VOCs detected in field blanks, and (3) selection of appropriate SRLs from among four potential SRLs for VOCs detected in field blanks and application of those SRLs to the groundwater data. An important conclusion from this study is that to ensure the quality of the data from groundwater samples, it was necessary to apply different methods of determining SRLs from field blank data to different VOCs, rather than use the same method for all VOCs. Four potential SRL values were defined by using three approaches: two values were defined by using a binomial probability method based on one-sided, nonparametric upper confidence limits, one was defined as equal to the maximum concentration detected in the field blanks, and one was defined as equal to the maximum laboratory method detection level used during the period when samples were collected for the project. The differences in detection frequencies and concentrations among different types of blanks (laboratory instrument blanks, source-solution blanks, and field blanks collected with three different sampling equipment configurations) and groundwater samples were used to infer the sources and mechanisms of contamination for each VOC detection in field blanks. Other chemical data for the groundwater samples (oxidation-reduction state, co-occurrence of VOCs, groundwater age) and ancillary information about the well sites (land use, presence of known sources of contamination) were used to evaluate whether the patterns of detections of VOCs in groundwater samples before and after application of potential SRLs were plausible. On this basis, the appropriate SRL was selected for each VOC that was determined to require an SRL. The SRLs for ethylbenzene [0.06 microgram per liter (μg/L)], m- and p-xylenes (0.33 μg/L), o-xylene (0.12 μg/L), toluene (0.69 μg/L), and 1,2,4-trimethylbenzene (0.56 μg/L) corresponded to the highest concentrations detected in the QCFBs and were selected because they resulted in the most censoring of groundwater data. Comparisons of hydrocarbon ratios in groundwater samples and blanks and comparisons between detection frequencies of the five hydrocarbons in groundwater samples and different types of blanks suggested three dominant sources of contamination that affected groundwater samples and blanks: (1) ethylbenzene, m- and p-xylenes, o-xylene, and toluene from fuel or exhaust components sorbed onto sampling lines, (2) toluene from vials and the source blank water, and (3) 1,2,4-trimethylbenzene from materials used for collection of samples for radon-222 analysis.

  14. Psychophysical Models for Signal Detection with Time Varying Uncertainty. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Gai, E.

    1975-01-01

    Psychophysical models for the behavior of the human operator in detection tasks which include change in detectability, correlation between observations and deferred decisions are developed. Classical Signal Detection Theory (SDT) is discussed and its emphasis on the sensory processes is contrasted to decision strategies. The analysis of decision strategies utilizes detection tasks with time varying signal strength. The classical theory is modified to include such tasks and several optimal decision strategies are explored. Two methods of classifying strategies are suggested. The first method is similar to the analysis of ROC curves, while the second is based on the relation between the criterion level (CL) and the detectability. Experiments to verify the analysis of tasks with changes of signal strength are designed. The results show that subjects are aware of changes in detectability and tend to use strategies that involve changes in the CL's.

  15. Influence of atmospheric properties on detection of wood-warbler nocturnal flight calls

    NASA Astrophysics Data System (ADS)

    Horton, Kyle G.; Stepanian, Phillip M.; Wainwright, Charlotte E.; Tegeler, Amy K.

    2015-10-01

    Avian migration monitoring can take on many forms; however, monitoring active nocturnal migration of land birds is limited to a few techniques. Avian nocturnal flight calls are currently the only method for describing migrant composition at the species level. However, as this method develops, more information is needed to understand the sources of variation in call detection. Additionally, few studies examine how detection probabilities differ under varying atmospheric conditions. We use nocturnal flight call recordings from captive individuals to explore the dependence of flight call detection on atmospheric temperature and humidity. Height or distance from origin had the largest influence on call detection, while temperature and humidity also influenced detectability at higher altitudes. Because flight call detection varies with both atmospheric conditions and flight height, improved monitoring across time and space will require correction for these factors to generate standardized metrics of songbird migration.

  16. Underwater Turbulence Detection Using Gated Wavefront Sensing Technique

    PubMed Central

    Bi, Ying; Xu, Xiping; Chow, Eddy Mun Tik

    2018-01-01

    Laser sensing has been applied in various underwater applications, ranging from underwater detection to laser underwater communications. However, there are several great challenges when profiling underwater turbulence effects. Underwater detection is greatly affected by the turbulence effect, where the acquired image suffers excessive noise, blurring, and deformation. In this paper, we propose a novel underwater turbulence detection method based on a gated wavefront sensing technique. First, we elaborate on the operating principle of gated wavefront sensing and wavefront reconstruction. We then setup an experimental system in order to validate the feasibility of our proposed method. The effect of underwater turbulence on detection is examined at different distances, and under different turbulence levels. The experimental results obtained from our gated wavefront sensing system indicate that underwater turbulence can be detected and analyzed. The proposed gated wavefront sensing system has the advantage of a simple structure and high detection efficiency for underwater environments. PMID:29518889

  17. Performance evaluation of FlowCytomix assays to quantify cytokines in patients with rheumatoid arthritis

    PubMed Central

    Wang, Xuefeng; Dong, Liyang; Liang, Yong; Ni, Hongchang; Tang, Jun; Xu, Chengcheng; Zhou, Yuepeng; Su, Yuting; Wang, Jun; Chen, Deyu; Mao, Chaoming

    2015-01-01

    Objectives: To compare the cytokine profile in RA patients and healthy control by using two methods-FlowCytomix assay and traditional ELISA. Methods: Cytokine levels were evaluated by FlowCytomix assay and ELISA in serum and supernatants of peripheral blood mononuclear cells (PBMC) cultures with and without stimulation by phytohaemagglutinin (PHA). Results: The levels of IL-6, IL-1β, and TNF-α were significantly higher in sera of RA patients than those of healthy controls. The levels of IL-22, IL-6, IL-1β, TNF-α, and IL-10 were higher in unstimulated PBMC culture supernatant of RA patients than those of healthy controls. PHA stimulation significantly increased the production of proinflammatory cytokines from PBMC with RA patients. Compared with detectable cytokine levels in sera, cytokine concentration in the supernatant of PBMCs was remarkably higher. FlowCytomix and ELISA showed significant correlation in detecting cytokines. However, the FlowCytomix assay detected more cytokines than ELISA. Conclusion: The supernatant of PBMCs provide a fine condition for the study of cytokine production because of the lack of interference factors in sera. The FlowCytomix assay is more sensitive than ELISA in detecting cytokines from RA patients. Multiple cytokine signatures using FlowCytomix assay may represent a more realistic approach in the future of personalized medicine in RA. PMID:26629129

  18. Comparison of chemiluminescence methods for analysis of hydrogen peroxide and hydroxyl radicals

    NASA Astrophysics Data System (ADS)

    Pehrman, R.; Amme, M.; Cachoir, C.

    2006-01-01

    Assessment of alpha radiolysis influence on the chemistry of geologically disposed spent fuel demands analytical methods for radiolytic product determination at trace levels. Several chemiluminescence methods for the detection of radiolytic oxidants hydrogen peroxide and hydroxyl radicals are tested. Two of hydrogen peroxide methods use luminol, catalyzed by either μ-peroxidase or hemin, one uses 10-methyl-9-(p-formylphenyl)-acridinium carboxylate trifluoromethanesulfonate and one potassium periodate. All recipes are tested as batch systems in basic conditions. For hydroxyl radical detection luminophores selected are 3-hydroxyphthalic hydrazide and rutin. Both methods are tested as batch systems. The results are compared and the applicability of the methods for near-field dissolution studies is discussed.

  19. Label-Free Toxin Detection by Means of Time-Resolved Electrochemical Impedance Spectroscopy

    PubMed Central

    Chai, Changhoon; Takhistov, Paul

    2010-01-01

    The real-time detection of trace concentrations of biological toxins requires significant improvement of the detection methods from those reported in the literature. To develop a highly sensitive and selective detection device it is necessary to determine the optimal measuring conditions for the electrochemical sensor in three domains: time, frequency and polarization potential. In this work we utilized a time-resolved electrochemical impedance spectroscopy for the detection of trace concentrations of Staphylococcus enterotoxin B (SEB). An anti-SEB antibody has been attached to the nano-porous aluminum surface using 3-aminopropyltriethoxysilane/glutaraldehyde coupling system. This immobilization method allows fabrication of a highly reproducible and stable sensing device. Using developed immobilization procedure and optimized detection regime, it is possible to determine the presence of SEB at the levels as low as 10 pg/mL in 15 minutes. PMID:22315560

  20. Assessment of soil-gas contamination at the 17th Street landfill, Fort Gordon, Georgia, 2011

    USGS Publications Warehouse

    Falls, W. Fred; Caldwell, Andral W.; Guimaraes, Wladmir G.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2012-01-01

    Assessments of contaminants in soil gas were conducted in two study areas at Fort Gordon, Georgia, in July and August of 2011 to supplement environmental contaminant data for previous studies at the 17th Street landfill. The two study areas include northern and eastern parts of the 17th Street landfill and the adjacent wooded areas to the north and east of the landfill. These study areas were chosen because of their close proximity to the surface water in Wilkerson Lake and McCoys Creek. A total of 48 soil-gas samplers were deployed for the July 28 to August 3, 2011, assessment in the eastern study area. The assessment mostly identified detections of total petroleum hydrocarbons (TPH), and gasoline- and diesel-range compounds, but also identified the presence of chlorinated solvents in six samplers, chloroform in three samplers, 2-methyl naphthalene in one sampler, and trimethylbenzene in one sampler. The TPH masses exceeded 0.02 microgram (μg) in all 48 samplers and exceeded 0.9 μg in 24 samplers. Undecane, one of the three diesel-range compounds used to calculate the combined mass for diesel-range compounds, was detected in 17 samplers and is the second most commonly detected compound in the eastern study area, exceeded only by the number of TPH detections. Six samplers had detections of toluene, but other gasoline compounds were detected with toluene in three of the samplers, including detections of ethylbenzene, meta- and para-xylene, and octane. All detections of chlorinated organic compounds had soil-gas masses equal to or less than 0.08 μg, including three detections of trichloroethene, three detections of perchloroethene, three chloroform detections, one 1,4-dichlorobenzene detection, and one 1,1,2-trichloroethane detection. Three methylated compounds were detected in the eastern study area, but were detected at or below method detection levels. A total of 32 soil-gas samplers were deployed for the August 11–24, 2011, assessment in the northern study area. All samplers in the survey had detections of TPH, but only eight of the samplers had detections of TPH greater than 0.9 mg. Four samplers had TPH detections greater than 9 mg; the only other fuel-related compounds detected in these four samplers included toluene in three of the samplers and undecane in the fourth sampler. Three samplers deployed along the western margin of the northern landfill had detections of both diesel-and gasoline-related compounds; however, the diesel-related compounds were detected at or below method detection levels. Seven samplers in the northern study area had detections of chlorinated compounds, including three perchloroethene detections, three chloroform detections, and one 1,4-dichloro-benzene detection. One sampler on the western margin of the landfill had detections of 1,2,4-trimethylbenzene and 1,3,5-tr-methylbenene below method detection levels.

  1. A Nanocoaxial-Based Electrochemical Sensor for the Detection of Cholera Toxin

    NASA Astrophysics Data System (ADS)

    Archibald, Michelle M.; Rizal, Binod; Connolly, Timothy; Burns, Michael J.; Naughton, Michael J.; Chiles, Thomas C.

    2015-03-01

    Sensitive, real-time detection of biomarkers is of critical importance for rapid and accurate diagnosis of disease for point of care (POC) technologies. Current methods do not allow for POC applications due to several limitations, including sophisticated instrumentation, high reagent consumption, limited multiplexing capability, and cost. Here, we report a nanocoaxial-based electrochemical sensor for the detection of bacterial toxins using an electrochemical enzyme-linked immunosorbent assay (ELISA) and differential pulse voltammetry (DPV). Proof-of-concept was demonstrated for the detection of cholera toxin (CT). The linear dynamic range of detection was 10 ng/ml - 1 μg/ml, and the limit of detection (LOD) was found to be 2 ng/ml. This level of sensitivity is comparable to the standard optical ELISA used widely in clinical applications. In addition to matching the detection profile of the standard ELISA, the nanocoaxial array provides a simple electrochemical readout and a miniaturized platform with multiplexing capabilities for the simultaneous detection of multiple biomarkers, giving the nanocoax a desirable advantage over the standard method towards POC applications. Sensitive, real-time detection of biomarkers is of critical importance for rapid and accurate diagnosis of disease for point of care (POC) technologies. Current methods do not allow for POC applications due to several limitations, including sophisticated instrumentation, high reagent consumption, limited multiplexing capability, and cost. Here, we report a nanocoaxial-based electrochemical sensor for the detection of bacterial toxins using an electrochemical enzyme-linked immunosorbent assay (ELISA) and differential pulse voltammetry (DPV). Proof-of-concept was demonstrated for the detection of cholera toxin (CT). The linear dynamic range of detection was 10 ng/ml - 1 μg/ml, and the limit of detection (LOD) was found to be 2 ng/ml. This level of sensitivity is comparable to the standard optical ELISA used widely in clinical applications. In addition to matching the detection profile of the standard ELISA, the nanocoaxial array provides a simple electrochemical readout and a miniaturized platform with multiplexing capabilities for the simultaneous detection of multiple biomarkers, giving the nanocoax a desirable advantage over the standard method towards POC applications. This work was supported by the National Institutes of Health (National Cancer Institute award No. CA137681 and National Institute of Allergy and Infectious Diseases Award No. AI100216).

  2. Residue determination and levels of glyphosate in surface waters, sediments and soils associated with oil palm plantation in Tasik Chini, Pahang, Malaysia

    NASA Astrophysics Data System (ADS)

    Mardiana-Jansar, K.; Ismail, B. S.

    2014-09-01

    Levels of glyphosate and its main metabolite were determined in surface water, soil and sediment samples from an oil palm plantation area located at Tasik Chini, Pahang, Malaysia. The optimization analytical method has been developed for the determination of glyphosate herbicide and its metabolite amino-methyl-phosphonic acid (AMPA) in surface waters to a level of 0.1μg/L, while in sediments and soils to a level of 0.5μg/g with a good linearity in the calibration range of 1-100μg/L. The procedure involves a pre-columnderivatization step with 9-fluorenyl-methyl-chloroformate (FMOC-Cl) yielding highly fluorescent derivatives of the analytes which can be determined by HPLC with fluorescence detection. In the field, levels of glyphosate in surface waters ranges from not detected to 1.0mg/L, while in soils and sediments were from not detected to 6.0mg/kg. For AMPA, the residues in surface waters were between not detected to 2.0mg/L, while in soil and sediment samples were from not detected to 5mg/kg. This variation of glyphosate and AMPA levels depended directly on time of pesticide application and the season.

  3. Temporal modulation transfer functions in cochlear implantees using a method that limits overall loudness cues

    PubMed Central

    Fraser, Matthew; McKay, Colette M.

    2012-01-01

    Temporal modulation transfer functions (TMTFs) were measured for six users of cochlear implants, using different carrier rates and levels. Unlike most previous studies investigating modulation detection, the experimental design limited potential effects of overall loudness cues. Psychometric functions (percent correct discrimination of modulated from unmodulated stimuli versus modulation depth) were obtained. For each modulation depth, each modulated stimulus was loudness balanced to the unmodulated reference stimulus, and level jitter was applied in the discrimination task. The loudness-balance data showed that the modulated stimuli were louder than the unmodulated reference stimuli with the same average current, thus confirming the need to limit loudness cues when measuring modulation detection. TMTFs measured in this way had a low-pass characteristic, with a cut-off frequency (at comfortably loud levels) similar to that for normal-hearing listeners. A reduction in level caused degradation in modulation detection efficiency and a lower-cut-off frequency (i.e. poorer temporal resolution). An increase in carrier rate also led to a degradation in modulation detection efficiency, but only at lower levels or higher modulation frequencies. When detection thresholds were expressed as a proportion of dynamic range, there was no effect of carrier rate for the lowest modulation frequency (50 Hz) at either level. PMID:22146425

  4. A method for the compensation of the effects of surface cloth impressions on polar backscatter applied to porous epoxy and biaxial graphite/epoxy composites

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I.; Bridal, S. L.; Holland, Mark R.; Handley, Scott M.; Miller, James G.

    1993-01-01

    The anisotropy of polar backscatter from graphite/epoxy composites is a potentially useful parameter for the characterization of porosity levels. However, the effects of release-cloth impressions on measured integrated polar backscatter levels are sufficient to inhibit the detection of porosity with this method. Recently, we developed a theoretical model to predict the frequency distribution of the backscattered power along the high-symmetry directions of release-cloth impressions. This study investigates experimentally the usefulness of limiting the bandwidth to regions not dominated by the scattering from the surface impressions, hence increasing the probability of detecting flaws such as porosity.

  5. Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Ziqiang

    1999-12-10

    Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based onmore » monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10 -8 M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results agreed well with literature values.« less

  6. Anesthetic level prediction using a QCM based E-nose.

    PubMed

    Saraoğlu, H M; Ozmen, A; Ebeoğlu, M A

    2008-06-01

    Anesthetic level measurement is a real time process. This paper presents a new method to measure anesthesia level in surgery rooms at hospitals using a QCM based E-Nose. The E-Nose system contains an array of eight different coated QCM sensors. In this work, the best linear reacting sensor is selected from the array and used in the experiments. Then, the sensor response time was observed about 15 min using classic method, which is impractical for on-line anesthetic level detection during a surgery. Later, the sensor transition data is analyzed to reach a decision earlier than the classical method. As a result, it is found out that the slope of transition data gives valuable information to predict the anesthetic level. With this new method, we achieved to find correct anesthetic levels within 100 s.

  7. Systems and methods for the detection of low-level harmful substances in a large volume of fluid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carpenter, Michael V.; Roybal, Lyle G.; Lindquist, Alan

    A method and device for the detection of low-level harmful substances in a large volume of fluid comprising using a concentrator system to produce a retentate and analyzing the retentate for the presence of at least one harmful substance. The concentrator system performs a method comprising pumping at least 10 liters of fluid from a sample source through a filter. While pumping, the concentrator system diverts retentate from the filter into a container. The concentrator system also recirculates at least part of the retentate in the container again through the filter. The concentrator system controls the speed of the pumpmore » with a control system thereby maintaining a fluid pressure less than 25 psi during the pumping of the fluid; monitors the quantity of retentate within the container with a control system, and maintains a reduced volume level of retentate and a target volume of retentate.« less

  8. PathFinder: reconstruction and dynamic visualization of metabolic pathways.

    PubMed

    Goesmann, Alexander; Haubrock, Martin; Meyer, Folker; Kalinowski, Jörn; Giegerich, Robert

    2002-01-01

    Beyond methods for a gene-wise annotation and analysis of sequenced genomes new automated methods for functional analysis on a higher level are needed. The identification of realized metabolic pathways provides valuable information on gene expression and regulation. Detection of incomplete pathways helps to improve a constantly evolving genome annotation or discover alternative biochemical pathways. To utilize automated genome analysis on the level of metabolic pathways new methods for the dynamic representation and visualization of pathways are needed. PathFinder is a tool for the dynamic visualization of metabolic pathways based on annotation data. Pathways are represented as directed acyclic graphs, graph layout algorithms accomplish the dynamic drawing and visualization of the metabolic maps. A more detailed analysis of the input data on the level of biochemical pathways helps to identify genes and detect improper parts of annotations. As an Relational Database Management System (RDBMS) based internet application PathFinder reads a list of EC-numbers or a given annotation in EMBL- or Genbank-format and dynamically generates pathway graphs.

  9. Paraffin section immunocytochemistry and cytosol-based ligand-binding assays for ER and PR detection in breast cancer: the time has come for more objectivity.

    PubMed

    Goussard, J

    1998-10-23

    The importance of the receptor level in breast cancer as an indicator of hormone response has been extensively studied for more than 20 years. Besides cytosol-based ligand-binding assays (dextran-coated charcoal assay, DCC), new methods using monoclonal antibodies raised against estrogen and progesterone receptors allow for the detection of receptors both in cytosol extracts (enzyme immunoassay, EIA) and in tissue sections (immunocytochemical assay, ICA). The biochemical assays (DCC and EIA) as well as the immunochemical detection (ICA) have specific qualities and produce original information which is useful for the therapeutic decision. While DCC gives a measure of the receptor level, whatever the real source of synthesis (normal and/or neoplastic tissue), ICA locates the positive cells and their relative proportion in the tumor. Both methods present their own advantages and disadvantages which are summarized in this study.

  10. Abseq: Ultrahigh-throughput single cell protein profiling with droplet microfluidic barcoding.

    PubMed

    Shahi, Payam; Kim, Samuel C; Haliburton, John R; Gartner, Zev J; Abate, Adam R

    2017-03-14

    Proteins are the primary effectors of cellular function, including cellular metabolism, structural dynamics, and information processing. However, quantitative characterization of proteins at the single-cell level is challenging due to the tiny amount of protein available. Here, we present Abseq, a method to detect and quantitate proteins in single cells at ultrahigh throughput. Like flow and mass cytometry, Abseq uses specific antibodies to detect epitopes of interest; however, unlike these methods, antibodies are labeled with sequence tags that can be read out with microfluidic barcoding and DNA sequencing. We demonstrate this novel approach by characterizing surface proteins of different cell types at the single-cell level and distinguishing between the cells by their protein expression profiles. DNA-tagged antibodies provide multiple advantages for profiling proteins in single cells, including the ability to amplify low-abundance tags to make them detectable with sequencing, to use molecular indices for quantitative results, and essentially limitless multiplexing.

  11. Abseq: Ultrahigh-throughput single cell protein profiling with droplet microfluidic barcoding

    NASA Astrophysics Data System (ADS)

    Shahi, Payam; Kim, Samuel C.; Haliburton, John R.; Gartner, Zev J.; Abate, Adam R.

    2017-03-01

    Proteins are the primary effectors of cellular function, including cellular metabolism, structural dynamics, and information processing. However, quantitative characterization of proteins at the single-cell level is challenging due to the tiny amount of protein available. Here, we present Abseq, a method to detect and quantitate proteins in single cells at ultrahigh throughput. Like flow and mass cytometry, Abseq uses specific antibodies to detect epitopes of interest; however, unlike these methods, antibodies are labeled with sequence tags that can be read out with microfluidic barcoding and DNA sequencing. We demonstrate this novel approach by characterizing surface proteins of different cell types at the single-cell level and distinguishing between the cells by their protein expression profiles. DNA-tagged antibodies provide multiple advantages for profiling proteins in single cells, including the ability to amplify low-abundance tags to make them detectable with sequencing, to use molecular indices for quantitative results, and essentially limitless multiplexing.

  12. Abseq: Ultrahigh-throughput single cell protein profiling with droplet microfluidic barcoding

    PubMed Central

    Shahi, Payam; Kim, Samuel C.; Haliburton, John R.; Gartner, Zev J.; Abate, Adam R.

    2017-01-01

    Proteins are the primary effectors of cellular function, including cellular metabolism, structural dynamics, and information processing. However, quantitative characterization of proteins at the single-cell level is challenging due to the tiny amount of protein available. Here, we present Abseq, a method to detect and quantitate proteins in single cells at ultrahigh throughput. Like flow and mass cytometry, Abseq uses specific antibodies to detect epitopes of interest; however, unlike these methods, antibodies are labeled with sequence tags that can be read out with microfluidic barcoding and DNA sequencing. We demonstrate this novel approach by characterizing surface proteins of different cell types at the single-cell level and distinguishing between the cells by their protein expression profiles. DNA-tagged antibodies provide multiple advantages for profiling proteins in single cells, including the ability to amplify low-abundance tags to make them detectable with sequencing, to use molecular indices for quantitative results, and essentially limitless multiplexing. PMID:28290550

  13. Recent developments in optical detection methods for microchip separations.

    PubMed

    Götz, Sebastian; Karst, Uwe

    2007-01-01

    This paper summarizes the features and performances of optical detection systems currently applied in order to monitor separations on microchip devices. Fluorescence detection, which delivers very high sensitivity and selectivity, is still the most widely applied method of detection. Instruments utilizing laser-induced fluorescence (LIF) and lamp-based fluorescence along with recent applications of light-emitting diodes (LED) as excitation sources are also covered in this paper. Since chemiluminescence detection can be achieved using extremely simple devices which no longer require light sources and optical components for focusing and collimation, interesting approaches based on this technique are presented, too. Although UV/vis absorbance is a detection method that is commonly used in standard desktop electrophoresis and liquid chromatography instruments, it has not yet reached the same level of popularity for microchip applications. Current applications of UV/vis absorbance detection to microchip separations and innovative approaches that increase sensitivity are described. This article, which contains 85 references, focuses on developments and applications published within the last three years, points out exciting new approaches, and provides future perspectives on this field.

  14. Insulation detection of electric vehicle batteries

    NASA Astrophysics Data System (ADS)

    Dai, Qiqi; Zhu, Zhongwen; Huang, Denggao; Du, Mingxing; Wei, Kexin

    2018-06-01

    In this paper, an electric vehicle insulation detection method with single side switching fixed resistance is designed, and the hardware and software design of the system are given. The experiment proves that the insulation detection system can detect the insulation resistance in a wide range of resistance values, and accurately report the fault level. This system can effectively monitor the insulation fault between the car body and the high voltage line and avoid the passengers from being injured.

  15. Modeling Concept Dependencies for Event Detection

    DTIC Science & Technology

    2014-04-04

    Gaussian Mixture Model (GMM). Jiang et al . [8] provide a summary of experiments for TRECVID MED 2010 . They employ low-level features such as SIFT and...event detection literature. Ballan et al . [2] present a method to introduce temporal information for video event detection with a BoW (bag-of-words...approach. Zhou et al . [24] study video event detection by encoding a video with a set of bag of SIFT feature vectors and describe the distribution with a

  16. Detection of low-level environmental chemical allergy by a long-term sensitization method.

    PubMed

    Fukuyama, Tomoki; Ueda, Hideo; Hayashi, Koichi; Tajima, Yukari; Shuto, Yasufumi; Saito, Toru R; Harada, Takanori; Kosaka, Tadashi

    2008-07-30

    Multiple chemical sensitivity (MCS) is characterized by various signs, including neurological disorders and allergy. Exposure may occur through a major event, such as a chemical spill, or from long-term contact with chemicals at low levels. We are interested in the allergenicity of MCS and the detection of low-level chemical-related hypersensitivity. We used long-term sensitization followed by low-dose challenge to evaluate sensitization by well-known Th2 type sensitizers (trimellitic anhydride (TMA) and toluene diisocyanate (TDI)) and a Th1 type sensitizer (2,4-dinitrochlorobenzene (DNCB)). After topically sensitizing BALB/c mice (9 times in 3 weeks) and challenging them with TMA, TDI or DNCB, we assayed their auricular lymph nodes (LNs) for number of lymphocytes, surface antigen expression of B cells, and local cytokine production, and measured antigen-specific serum IgE levels. TMA and TDI induced marked increases in levels of antigen-specific serum IgE and of Th2 cytokines (IL-4, IL-5, IL-10, and IL-13) produced by ex vivo restimulated lymph node cells. DNCB induced a marked increase in Th1 cytokine (IL-2, IFN-gamma, and TNF-alpha) levels, but antigen-specific serum IgE levels were not elevated. All chemicals induced significant increases in number of lymphocytes and surface antigen expression of B cells. Our mouse model enabled the identification and characterization of chemical-related allergic reactions at low levels. This long-term sensitization method would be useful for detecting environmental chemical-related hypersensitivity.

  17. A Study on the Model of Detecting the Liquid Level of Sealed Containers Based on Kirchhoff Approximation Theory.

    PubMed

    Zhang, Bin; Song, Wen-Ai; Wei, Yue-Juan; Zhang, Dong-Song; Liu, Wen-Yi

    2017-06-15

    By simulating the sound field of a round piston transducer with the Kirchhoff integral theorem and analyzing the shape of ultrasound beams and propagation characteristics in a metal container wall, this study presents a model for calculating the echo sound pressure by using the Kirchhoff paraxial approximation theory, based on which and according to different ultrasonic impedance between gas and liquid media, a method for detecting the liquid level from outside of sealed containers is proposed. Then, the proposed method is evaluated through two groups of experiments. In the first group, three kinds of liquid media with different ultrasonic impedance are used as detected objects; the echo sound pressure is calculated by using the proposed model under conditions of four sets of different wall thicknesses. The changing characteristics of the echo sound pressure in the entire detection process are analyzed, and the effects of different ultrasonic impedance of liquids on the echo sound pressure are compared. In the second group, taking water as an example, two transducers with different radii are selected to measure the liquid level under four sets of wall thickness. Combining with sound field characteristics, the influence of different size transducers on the pressure calculation and detection resolution are discussed and analyzed. Finally, the experimental results indicate that measurement uncertainly is better than ±5 mm, which meets the industrial inspection requirements.

  18. A Study on the Model of Detecting the Liquid Level of Sealed Containers Based on Kirchhoff Approximation Theory

    PubMed Central

    Zhang, Bin; Song, Wen-Ai; Wei, Yue-Juan; Zhang, Dong-Song; Liu, Wen-Yi

    2017-01-01

    By simulating the sound field of a round piston transducer with the Kirchhoff integral theorem and analyzing the shape of ultrasound beams and propagation characteristics in a metal container wall, this study presents a model for calculating the echo sound pressure by using the Kirchhoff paraxial approximation theory, based on which and according to different ultrasonic impedance between gas and liquid media, a method for detecting the liquid level from outside of sealed containers is proposed. Then, the proposed method is evaluated through two groups of experiments. In the first group, three kinds of liquid media with different ultrasonic impedance are used as detected objects; the echo sound pressure is calculated by using the proposed model under conditions of four sets of different wall thicknesses. The changing characteristics of the echo sound pressure in the entire detection process are analyzed, and the effects of different ultrasonic impedance of liquids on the echo sound pressure are compared. In the second group, taking water as an example, two transducers with different radii are selected to measure the liquid level under four sets of wall thickness. Combining with sound field characteristics, the influence of different size transducers on the pressure calculation and detection resolution are discussed and analyzed. Finally, the experimental results indicate that measurement uncertainly is better than ±5 mm, which meets the industrial inspection requirements. PMID:28617326

  19. Near-infrared hyperspectral imaging for detecting Aflatoxin B1 of maize kernels

    USDA-ARS?s Scientific Manuscript database

    The feasibility of detecting the Aflatoxin B1 in maize kernels inoculated with Aspergillus flavus conidia in the field was assessed using near-infrared hyperspectral imaging technique. After pixel-level calibration, wavelength dependent offset, the masking method was adopted to reduce the noise and ...

  20. Evaluation of the performance of the IQ-Check kits and the USDA Microbiology Laboratory Guidebook methods for detection of Shiga toxin-producing Escherichia coli (STEC) and STEC and Salmonella simultaneously in ground beef.

    PubMed

    Baranzoni, G M; Fratamico, P M; Boccia, F; Bagi, L K; Kim, G-H; Anastasio, A; Pepe, T

    2017-03-01

    To evaluate the performance of the IQ-Check kits and the USDA Microbiology Laboratory Guidebook (MLG) methods for detection of the top seven Shiga toxin-producing Escherichia coli (STEC) (O157:H7, O26, O45, O103, O111, O121 and O145) in ground beef and both STEC and Salmonella in co-inoculated samples. Ground beef samples inoculated with ~10 CFU of STEC or both STEC and Salmonella Typhimurium were stored at 4°C for 72 h, followed by screening with the IQ-Check and BAX System kit (MLG) methods that employ different enrichment media. STEC and S. Typhimurium were detected after 12 and 18 h and their presence was confirmed by colony isolation. Both methods were able to detect STEC in ground beef after 12 h of enrichment in samples inoculated with low levels of the pathogen. STEC and S. Typhimurium can be detected and isolated in co-inoculated ground beef samples. The IQ-Check methods are comparable to the MLG methods for detection of STEC and simultaneous detection of STEC and S. Typhimurium in seeded ground beef after a short enrichment time, thus the IQ-Check method can be useful for the food industry for rapid detection of these pathogens. Published 2016. This article has been contributed to by US Government employees and their work is in the public domain in the USA.

  1. Automatically Detecting Likely Edits in Clinical Notes Created Using Automatic Speech Recognition

    PubMed Central

    Lybarger, Kevin; Ostendorf, Mari; Yetisgen, Meliha

    2017-01-01

    The use of automatic speech recognition (ASR) to create clinical notes has the potential to reduce costs associated with note creation for electronic medical records, but at current system accuracy levels, post-editing by practitioners is needed to ensure note quality. Aiming to reduce the time required to edit ASR transcripts, this paper investigates novel methods for automatic detection of edit regions within the transcripts, including both putative ASR errors but also regions that are targets for cleanup or rephrasing. We create detection models using logistic regression and conditional random field models, exploring a variety of text-based features that consider the structure of clinical notes and exploit the medical context. Different medical text resources are used to improve feature extraction. Experimental results on a large corpus of practitioner-edited clinical notes show that 67% of sentence-level edits and 45% of word-level edits can be detected with a false detection rate of 15%. PMID:29854187

  2. Antimicrobial Use and Resistance in Swine Waste Treatment Systems▿

    PubMed Central

    Jindal, Archana; Kocherginskaya, Svetlana; Mehboob, Asma; Robert, Matthew; Mackie, Roderick I.; Raskin, Lutgarde; Zilles, Julie L.

    2006-01-01

    Chlortetracycline and the macrolide tylosin were identified as commonly used antimicrobials for growth promotion and prophylaxis in swine production. Resistance to these antimicrobials was measured throughout the waste treatment processes at five swine farms by culture-based and molecular methods. Conventional farm samples had the highest levels of resistance with both culture-based and molecular methods and had similar levels of resistance despite differences in antimicrobial usage. The levels of resistance in organic farm samples, where no antimicrobials were used, were very low by a culture-based method targeting fecal streptococci. However, when the same samples were analyzed with a molecular method detecting methylation of a specific nucleotide in the 23S rRNA that results in resistance to macrolides, lincosamides, and streptogramin B (MLSB), an unexpectedly high level of resistant rRNA (approximately 50%) was observed, suggesting that the fecal streptococci were not an appropriate target group to evaluate resistance in the overall microbial community and that background levels of MLSB resistance may be substantial. All of the feed samples tested, including those from the organic farm, contained tetracycline resistance genes. Generally, the same tetracycline resistance genes and frequency of detection were found in the manure and lagoon samples for each commercial farm. The levels of tetracycline and MLSB resistance remained high throughout the waste treatment systems, suggesting that the potential impact of land application of treated wastes and waste treatment by-products on environmental levels of resistance should be investigated further. PMID:17041160

  3. Salmonella detection in poultry samples. Comparison of two commercial real-time PCR systems with culture methods for the detection of Salmonella spp. in environmental and fecal samples of poultry.

    PubMed

    Sommer, D; Enderlein, D; Antakli, A; Schönenbrücher, H; Slaghuis, J; Redmann, T; Lierz, M

    2012-01-01

    The efficiency of two commercial PCR methods based on real-time technology, the foodproof® Salmonella detection system and the BAX® PCR Assay Salmonella system was compared to standardized culture methods (EN ISO 6579:2002 - Annex D) for the detection of Salmonella spp. in poultry samples. Four sample matrices (feed, dust, boot swabs, feces) obtained directly from poultry flocks, as well as artificially spiked samples of the same matrices, were used. All samples were tested for Salmonella spp. using culture methods first as the gold standard. In addition samples spiked with Salmonella Enteridis were tested to evaluate the sensitivity of both PCR methods. Furthermore all methods were evaluated in an annual ring-trial of the National Salmonella Reference Laboratory of Germany. Salmonella detection in the matrices feed, dust and boot swabs were comparable in both PCR systems whereas the results from feces differed markedly. The quality, especially the freshness, of the fecal samples had an influence on the sensitivity of the real-time PCR and the results of the culture methods. In fresh fecal samples an initial spiking level of 100cfu/25g Salmonella Enteritidis was detected. Two-days-dried fecal samples allowed the detection of 14cfu/25g. Both real- time PCR protocols appear to be suitable for the detection of Salmonella spp. in all four matrices. The foodproof® system detected eight samples more to be positive compared to the BAX® system, but had a potential false positive result in one case. In 7-days-dried samples none of the methods was able to detect Salmonella likely through letal cell damage. In general the advantage of PCR analyses over the culture method is the reduction of working time from 4-5 days to only 2 days. However, especially for the analysis of fecal samples official validation should be conducted according to the requirement of EN ISO6579:2002 - Annex D.

  4. A survey of the use of soy in processed Turkish meat products and detection of genetic modification.

    PubMed

    Ulca, Pelin; Balta, Handan; Senyuva, Hamide Z

    2014-01-01

    To screen for possible illegal use of soybeans in meat products, the performance characteristics of a commercial polymer chain reaction (PCR) kit for detection of soybean DNA in raw and cooked meat products were established. Minced chicken and beef products containing soybean at levels from 0.1% to 10.0% were analysed by real-time PCR to amplify the soybean lectin gene. The PCR method could reliably detect the addition of soybean at a level of 0.1%. A survey of 38 Turkish processed meat products found only six samples to be negative for the presence of soybean. In 32 (84%) positive samples, 13 (34%) contained levels of soy above 0.1%. Of soybean positive samples, further DNA analysis was conducted by real-time PCR to detect whether genetically modified (GM) soybean had been used. Of 32 meat samples containing soybean, two samples were positive for GM modification.

  5. The Effect of Two Methods of Pomegranate (Punica granatum L) Juice Extraction on Quality During Storage at 4°C

    PubMed Central

    Antunes, Dulce

    2004-01-01

    The effect of two extraction methods of pomegranate juice on its quality and stability was evaluated. The first method consisted of separation of the seeds from fruits and centrifugation. The second method consisted of squeezing fruit halves with an electric lemon squeezer. During a period of 72 hours of cold storage at 4°C, the juices were evaluated for the presence of sugars, organic acids, and anthocyanins. Delphinidin 3-glucoside was identified to be the major anthocyanin present at the level of 45–69 mg/L. Among the organic acids, oxalic and tartaric acids dominated. The major sugars detected in pomegranate juice were glucose and sucrose. No significant differences in the content of sugars, organic acids, or anthocyanins in juices obtained through application of the two different extraction methods were detected, with the exception of the drastic decrease of cyanidin 3,5-diglucoside level in juice obtained by seed centrifugation. The pH did not show differences between treatments. Titrable acidity and the level of sugars expressed as °Brix decreased after 32 and 15 hours after extraction, respectively, when juice was obtained by centrifuging the seeds. PMID:15577198

  6. The Effect of Two Methods of Pomegranate (Punica granatum L) Juice Extraction on Quality During Storage at $4^\\circ$ C.

    PubMed

    Miguel, Graça; Dandlen, Susana; Antunes, Dulce; Neves, Alcinda; Martins, Denise

    2004-01-01

    The effect of two extraction methods of pomegranate juice on its quality and stability was evaluated. The first method consisted of separation of the seeds from fruits and centrifugation. The second method consisted of squeezing fruit halves with an electric lemon squeezer. During a period of 72 hours of cold storage at $4^\\circ$ C, the juices were evaluated for the presence of sugars, organic acids, and anthocyanins. Delphinidin 3-glucoside was identified to be the major anthocyanin present at the level of 45-69 mg/L. Among the organic acids, oxalic and tartaric acids dominated. The major sugars detected in pomegranate juice were glucose and sucrose. No significant differences in the content of sugars, organic acids, or anthocyanins in juices obtained through application of the two different extraction methods were detected, with the exception of the drastic decrease of cyanidin $3,5$ -diglucoside level in juice obtained by seed centrifugation. The pH did not show differences between treatments. Titrable acidity and the level of sugars expressed as ${}^{\\circ}$ Brix decreased after 32 and 15 hours after extraction, respectively, when juice was obtained by centrifuging the seeds.

  7. Mitosis Counting in Breast Cancer: Object-Level Interobserver Agreement and Comparison to an Automatic Method

    PubMed Central

    Veta, Mitko; van Diest, Paul J.; Jiwa, Mehdi; Al-Janabi, Shaimaa; Pluim, Josien P. W.

    2016-01-01

    Background Tumor proliferation speed, most commonly assessed by counting of mitotic figures in histological slide preparations, is an important biomarker for breast cancer. Although mitosis counting is routinely performed by pathologists, it is a tedious and subjective task with poor reproducibility, particularly among non-experts. Inter- and intraobserver reproducibility of mitosis counting can be improved when a strict protocol is defined and followed. Previous studies have examined only the agreement in terms of the mitotic count or the mitotic activity score. Studies of the observer agreement at the level of individual objects, which can provide more insight into the procedure, have not been performed thus far. Methods The development of automatic mitosis detection methods has received large interest in recent years. Automatic image analysis is viewed as a solution for the problem of subjectivity of mitosis counting by pathologists. In this paper we describe the results from an interobserver agreement study between three human observers and an automatic method, and make two unique contributions. For the first time, we present an analysis of the object-level interobserver agreement on mitosis counting. Furthermore, we train an automatic mitosis detection method that is robust with respect to staining appearance variability and compare it with the performance of expert observers on an “external” dataset, i.e. on histopathology images that originate from pathology labs other than the pathology lab that provided the training data for the automatic method. Results The object-level interobserver study revealed that pathologists often do not agree on individual objects, even if this is not reflected in the mitotic count. The disagreement is larger for objects from smaller size, which suggests that adding a size constraint in the mitosis counting protocol can improve reproducibility. The automatic mitosis detection method can perform mitosis counting in an unbiased way, with substantial agreement with human experts. PMID:27529701

  8. Method validation for the determination of ochratoxin A in green and soluble coffee by immunoaffinity column cleanup and liquid chromatography.

    PubMed

    Diaz, G J; Ariza, D; Perilla, N S

    2004-06-01

    A method was validated for the determination of ochratoxin A (OTA) in soluble and green coffee. Performance parameters evaluated included selectivity, accuracy, intermediate precision, linearity, limit of detection, limit of quantitation, and ruggedness. The method was found to be selective for OTA in both matrices tested. Recovery rates from soluble coffee samples ranged from 73.5 to 91.2%, and from green coffee samples from 68.7 to 84.5%. The intermediate precision (RSDr) was between 9.1 and 9.4% for soluble coffee and between 14.3 and 15.5% for green coffee analysis. The linearity of the standard calibration curve (r(2)) was <0.999 for OTA levels of 1.0-20.0 μg/kg in coffee samples. The limit of detection was determined to be 0.01 ng of OTA on column, while the limit of quantitation was found to be 0.03 ng on column. The limit of quantitation is equivalent to 0.6 μg/kg in soluble coffee samples and 0.3 μg/kg in green coffee samples. The results of the ruggedness trial showed two factors are critical for soluble coffee analysis: the extraction method, and the flow rate of the mobile phase. For green coffee analysis two critical factors detected were the extraction method and the storage temperature of the immunoaffinity column.Five samples of soluble coffee and 42 of green coffee were analysed using the validated method. All soluble coffee samples contained OTA at levels that ranged from 8.4 to 13.9 μg/kg. Six of the 42 green coffee samples analysed (14.3%) contained OTA at levels ranging from 0.9 to 19.4 μg/kg. The validated method can be used to monitor OTA levels in Colombian coffee for export or for local consumption.

  9. Mesh-free based variational level set evolution for breast region segmentation and abnormality detection using mammograms.

    PubMed

    Kashyap, Kanchan L; Bajpai, Manish K; Khanna, Pritee; Giakos, George

    2018-01-01

    Automatic segmentation of abnormal region is a crucial task in computer-aided detection system using mammograms. In this work, an automatic abnormality detection algorithm using mammographic images is proposed. In the preprocessing step, partial differential equation-based variational level set method is used for breast region extraction. The evolution of the level set method is done by applying mesh-free-based radial basis function (RBF). The limitation of mesh-based approach is removed by using mesh-free-based RBF method. The evolution of variational level set function is also done by mesh-based finite difference method for comparison purpose. Unsharp masking and median filtering is used for mammogram enhancement. Suspicious abnormal regions are segmented by applying fuzzy c-means clustering. Texture features are extracted from the segmented suspicious regions by computing local binary pattern and dominated rotated local binary pattern (DRLBP). Finally, suspicious regions are classified as normal or abnormal regions by means of support vector machine with linear, multilayer perceptron, radial basis, and polynomial kernel function. The algorithm is validated on 322 sample mammograms of mammographic image analysis society (MIAS) and 500 mammograms from digital database for screening mammography (DDSM) datasets. Proficiency of the algorithm is quantified by using sensitivity, specificity, and accuracy. The highest sensitivity, specificity, and accuracy of 93.96%, 95.01%, and 94.48%, respectively, are obtained on MIAS dataset using DRLBP feature with RBF kernel function. Whereas, the highest 92.31% sensitivity, 98.45% specificity, and 96.21% accuracy are achieved on DDSM dataset using DRLBP feature with RBF kernel function. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Determination of Aristolochic Acid in Botanicals and Dietary Supplements by Liquid Chromatography with Ultraviolet Detection and by Liquid Chromatography/Mass Spectrometry: Single Laboratory Validation Confirmation

    PubMed Central

    Trujillo, William A.; Sorenson, Wendy R.; La Luzerne, Paul; Austad, John W.; Sullivan, Darryl

    2008-01-01

    The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 μg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid Chromatography with ultraviolet detection (LC-UV) and LC/mass Spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 μg/g level, between 102 and 103% at the 10 μg/g level, and 104% at the 30 μg/g level. PMID:16915829

  11. Determination of aristolochic acid in botanicals and dietary supplements by liquid chromatography with ultraviolet detection and by liquid chromatography/mass spectrometry: single laboratory validation confirmation.

    PubMed

    Trujillo, William A; Sorenson, Wendy R; La Luzerne, Paul; Austad, John W; Sullivan, Darryl

    2006-01-01

    The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 microg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid chromatography with ultraviolet detection (LC-UV) and LC/mass spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 microg/g level, between 102 and 103% at the 10 microg/g level, and 104% at the 30 microg/g level.

  12. CAD scheme for detection of hemorrhages and exudates in ocular fundus images

    NASA Astrophysics Data System (ADS)

    Hatanaka, Yuji; Nakagawa, Toshiaki; Hayashi, Yoshinori; Mizukusa, Yutaka; Fujita, Akihiro; Kakogawa, Masakatsu; Kawase, Kazuhide; Hara, Takeshi; Fujita, Hiroshi

    2007-03-01

    This paper describes a method for detecting hemorrhages and exudates in ocular fundus images. The detection of hemorrhages and exudates is important in order to diagnose diabetic retinopathy. Diabetic retinopathy is one of the most significant factors contributing to blindness, and early detection and treatment are important. In this study, hemorrhages and exudates were automatically detected in fundus images without using fluorescein angiograms. Subsequently, the blood vessel regions incorrectly detected as hemorrhages were eliminated by first examining the structure of the blood vessels and then evaluating the length-to-width ratio. Finally, the false positives were eliminated by checking the following features extracted from candidate images: the number of pixels, contrast, 13 features calculated from the co-occurrence matrix, two features based on gray-level difference statistics, and two features calculated from the extrema method. The sensitivity of detecting hemorrhages in the fundus images was 85% and that of detecting exudates was 77%. Our fully automated scheme could accurately detect hemorrhages and exudates.

  13. Optimization and validation of a method for the determination of the refractive index of milk serum based on the reaction between milk and copper(II) sulfate to detect milk dilutions.

    PubMed

    Rezende, Patrícia Sueli; Carmo, Geraldo Paulo do; Esteves, Eduardo Gonçalves

    2015-06-01

    We report the use of a method to determine the refractive index of copper(II) serum (RICS) in milk as a tool to detect the fraudulent addition of water. This practice is highly profitable, unlawful, and difficult to deter. The method was optimized and validated and is simple, fast and robust. The optimized method yielded statistically equivalent results compared to the reference method with an accuracy of 0.4% and quadrupled analytical throughput. Trueness, precision (repeatability and intermediate precision) and ruggedness are determined to be satisfactory at a 95.45% confidence level. The expanded uncertainty of the measurement was ±0.38°Zeiss at the 95.45% confidence level (k=3.30), corresponding to 1.03% of the minimum measurement expected in adequate samples (>37.00°Zeiss). Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    PubMed

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  15. Detection of low-level DNA mutation by ARMS-blocker-Tm PCR.

    PubMed

    Qu, Shoufang; Liu, Licheng; Gan, Shuzhen; Feng, Huahua; Zhao, Jingyin; Zhao, Jing; Liu, Qi; Gao, Shangxiang; Chen, Weijun; Wang, Mengzhao; Jiang, Yongqiang; Huang, Jie

    2016-02-01

    Low-level DNA mutations play important roles in cancer prognosis and treatment. However, most existing methods for the detection of low-level DNA mutations are insufficient for clinical applications because of the high background of wild-type DNA. In this study, a novel assay based on Tm-dependent inhibition of wild type template amplification was developed. The defining characteristic of this assay is an additional annealing step was introduced into the ARMS-blocker PCR. The temperature of this additional annealing step is equal to the Tm of the blocker. Due to this additional annealing step, the blocker can preferentially and specifically bind the wild-type DNA. Thus, the inhibition of wild type template is realized and the mutant DNA is enriched. The sensitivity of this assay was between 10(-4) and 10(-5), which is approximately 5 to 10 times greater than the sensitivity of the assay without the additional annealing step. To evaluate the performance of this assay in detecting K-ras mutation, we analyzed 100 formalin-fixed paraffin-embedded (FFPE) specimens from colorectal cancer patients using this new assay and Sanger sequencing. Of the clinical samples, 27 samples were positive for K-ras mutation by both methods. Our results indicated that this new assay is a highly selective, convenient, and economical method for detecting rare mutations in the presence of higher concentrations of wild-type DNA. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Simultaneous Determination of Oxysterols, Cholesterol and 25-Hydroxy-Vitamin D3 in Human Plasma by LC-UV-MS

    PubMed Central

    Narayanaswamy, Rohini; Iyer, Vignesh; Khare, Prachi; Bodziak, Mary Lou; Badgett, Darlene; Zivadinov, Robert; Weinstock-Guttman, Bianca; Rideout, Todd C.; Ramanathan, Murali; Browne, Richard W.

    2015-01-01

    Background Oxysterols are promising biomarkers of neurodegenerative diseases that are linked with cholesterol and vitamin D metabolism. There is an unmet need for methods capable of sensitive, and simultaneous quantitation of multiple oxysterols, vitamin D and cholesterol pathway biomarkers. Methods A method for simultaneous determination of 5 major oxysterols, 25-hydroxy vitamin D3 and cholesterol in human plasma was developed. Total oxysterols were prepared by room temperature saponification followed by solid phase extraction from plasma spiked with deuterated internal standards. Oxysterols were resolved by reverse phase HPLC using a methanol/water/0.1% formic acid gradient. Oxysterols and 25-hydroxy vitamin D3 were detected with atmospheric pressure chemical ionization mass spectrometry in positive ion mode; in-series photodiode array detection at 204nm was used for cholesterol. Method validation studies were performed. Oxysterol levels in 220 plasma samples from healthy control subjects, multiple sclerosis and other neurological disorders patients were quantitated. Results Our method quantitated 5 oxysterols, cholesterol and 25-hydroxy vitamin D3 from 200 μL plasma in 35 minutes. Recoveries were >85% for all analytes and internal standards. The limits of detection were 3-10 ng/mL for oxysterols and 25-hydroxy vitamin D3 and 1 μg/mL for simultaneous detection of cholesterol. Analytical imprecision was <10 %CV for 24(S)-, 25-, 27-, 7α-hydroxycholesterol (HC) and cholesterol and ≤15 % for 7-keto-cholesterol. Multiple Sclerosis and other neurological disorder patients had lower 27-hydroxycholesterol levels compared to controls whereas 7α-hydroxycholesterol was lower specifically in Multiple Sclerosis. Conclusion The method is suitable for measuring plasma oxysterols levels in human health and disease. Analysis of human plasma indicates that the oxysterol, bile acid precursors 7α-hydroxycholesterol and 27-hydroxycholesterol are lower in Multiple Sclerosis and may serve as potential biomarkers of disease. PMID:25875771

  17. Development of an analytical method for detecting nitrofurans in bee pollen by liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Park, Mi Sun; Kim, Kyung Tae; Kang, Jong Seong

    2017-03-01

    Bee pollen collected by honeybees, which is in powdered form, is a good nutritional supplement. Nitrofuran antibiotics are assumed not to be present in bee pollen, which is important as the level of antibiotics in bee pollen is strongly regulated in many countries. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to detect nitrofurans in honey has been developed, but this method is not suitable for bee pollen because of it being in powdered form. During preparation of bee pollen samples, the dispersal of powder particles in an aqueous solution often makes them susceptible to forming an emulsion with solvent components such as hexane and ethyl acetate. This may reduce the reproducibility and sensitivity of analyses of nitrofuran levels in bee pollen. Therefore, we attempted to optimize the sample preparation conditions to detect nitrofurans in bee pollen by determining three nitrofuran residues, namely, 3-amino-2-oxazolidinone (AOZ), 3-amino-5-methyl-morpholino-2-oxazolidinone (AMOZ), and 1-aminohydantoin (AHD), using LC-MS/MS. The optimized method prevented the formation of powder-induced emulsion. To verify the reproducibility and sensitivity of this method, it was validated using nitrofuran-free bee pollen spiked with analytes with different side chains at 1.0, 2.0, and 5.0μgkg -1 . The accuracy levels were 94.1%-104.0% and the coefficients of variation were less than 12%. The limits of detection for AOZ, AMOZ, and AHD were 0.18, 0.25, and 0.30μgkg -1 , respectively, while their limits of quantitation were 0.59, 0.83, and 1.00μgkg -1 . The LC-MS/MS method developed to analyze nitrofuran in bee pollen should contribute to the quality control of bee pollen and food safety. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Evaluation of a polymerase chain reaction-based system for detection of Salmonella enteritidis, Escherichia coli O157:H7, Listeria spp., and Listeria monocytogenes on fresh fruits and vegetables.

    PubMed

    Shearer, A E; Strapp, C M; Joerger, R D

    2001-06-01

    A polymerase chain reaction (PCR)-based detection system, BAX, was evaluated for its sensitivity in detecting Salmonella Enteritidis, Escherichia coli O157:H7, Listeria sp., and Listeria monocytogenes on fresh produce. Fifteen different types of produce (alfalfa sprouts, green peppers, parsley, white cabbage, radishes, onions, carrots, mushrooms, leaf lettuce, tomatoes, strawberries, cantaloupe, mango, apples, and oranges) were inoculated, in separate studies, with Salmonella Enteritidis, E. coli O157:H7, and L. monocytogenes down to the predicted level of 1 CFU per 25-g sample. Detection by BAX was compared to recovery of the inoculated bacteria by culture methods according to the Food and Drug Administration's (FDA) Bacteriological Analytical Manual (BAM). BAX was essentially as sensitive as the culture-based method in detecting Salmonella Enteritidis and L. monocytogenes and more sensitive than the culture-based method for the detection of E. coli O157:H7 on green pepper, carrot, radish, and sprout samples. Detection of the pathogenic bacteria in samples spiked with a predicted number of less than 10 CFU was possible for most produce samples, but both methods failed to detect L. monocytogenes on carrot samples and one of two mushroom and onion samples spiked with less than 100 CFU. Both BAX and the culture method were also unable to consistently recover low numbers of E. coli O157:H7 from alfalfa sprouts. The PCR method allowed detection of Salmonella Enteritidis, E. coli O157:H7, and L. monocytogenes at least 2 days earlier than the conventional culture methods.

  19. Analysis of alkyl phosphates in petroleum samples by comprehensive two-dimensional gas chromatography with nitrogen phosphorus detection and post-column Deans switching.

    PubMed

    Nizio, Katie D; Harynuk, James J

    2012-08-24

    Alkyl phosphate based gellants used as viscosity builders for fracturing fluids used in the process of hydraulic fracturing have been implicated in numerous refinery-fouling incidents in North America. In response, industry developed an inductively coupled plasma optical emission spectroscopy (ICP-OES) based method for the analysis of total volatile phosphorus in distillate fractions of crude oil; however, this method is plagued by poor precision and a high limit of detection (0.5±1μg phosphorus mL(-1)). Furthermore this method cannot provide speciation information, which is critical for developing an understanding of the challenge of alkyl phosphates at a molecular level. An approach using comprehensive two-dimensional gas chromatography with nitrogen phosphorus detection (GC×GC-NPD) and post-column Deans switching is presented. This method provides qualitative and quantitative profiles of alkyl phosphates in industrial petroleum samples with increased precision and at levels comparable to or below those achievable by ICP-OES. A recovery study in a fracturing fluid sample and a profiling study of alkyl phosphates in four recovered fracturing fluid/crude oil mixtures (flowback) are also presented. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Simultaneous determination of cyanogen chloride and cyanogen bromide in treated water at sub-microg/L levels by a new solid-phase microextraction-gas chromatographic-electron-capture detection method.

    PubMed

    Cancho, B; Ventur, F; Galceran, M

    2000-11-03

    A headspace solid-phase microextraction (HS-SPME) procedure has been developed and applied for the determination of cyanogen halides in treated water samples at microg/L concentrations. Several SPME coatings were tested, the divinylbenzene-Carboxen-polydimethylsiloxane fiber being the most appropriate coating. GC-electron-capture detection was used for separation and quantitation. Experimental parameters such as sample volume, addition of a salt, extraction time and desorption conditions were studied. The optimized method has an acceptable linearity, good precision, with RSD values <10% for both compounds, and it is sufficiently sensitive to detect ng/L levels. HS-SPME was compared with liquid-liquid microextraction (US Environmental Protection Agency Method 551.1) for the analysis of spiked ultrapure and granular activated carbon filtered water samples. There was good agreement between the results from both methods. Finally, the optimized procedure was applied to determine both compounds at the Barcelona water treatment plant (N.E. Spain). Cyanogen chloride in treated water was <1.0 microg/L and cyanogen bromide ranged from 3.2 to 6.4 microg/L.

  1. A positive chemical ionization GC/MS method for the determination of airborne ethylene glycol and propylene glycols in non-occupational environments.

    PubMed

    Zhu, Jiping; Feng, Yong-Lai; Aikawa, Bio

    2004-11-01

    An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).

  2. A multichannel decision-level fusion method for T wave alternans detection

    NASA Astrophysics Data System (ADS)

    Ye, Changrong; Zeng, Xiaoping; Li, Guojun; Shi, Chenyuan; Jian, Xin; Zhou, Xichuan

    2017-09-01

    Sudden cardiac death (SCD) is one of the most prominent causes of death among patients with cardiac diseases. Since ventricular arrhythmia is the main cause of SCD and it can be predicted by T wave alternans (TWA), the detection of TWA in the body-surface electrocardiograph (ECG) plays an important role in the prevention of SCD. But due to the multi-source nature of TWA, the nonlinear propagation through thorax, and the effects of the strong noises, the information from different channels is uncertain and competitive with each other. As a result, the single-channel decision is one-sided while the multichannel decision is difficult to reach a consensus on. In this paper, a novel multichannel decision-level fusion method based on the Dezert-Smarandache Theory is proposed to address this issue. Due to the redistribution mechanism for highly competitive information, higher detection accuracy and robustness are achieved. It also shows promise to low-cost instruments and portable applications by reducing demands for the synchronous sampling. Experiments on the real records from the Physikalisch-Technische Bundesanstalt diagnostic ECG database indicate that the performance of the proposed method improves by 12%-20% compared with the one-dimensional decision method based on the periodic component analysis.

  3. Detection of biological molecules using chemical amplification and optical sensors

    DOEpatents

    Van Antwerp, William Peter; Mastrototaro, John Joseph

    2000-01-01

    Methods are provided for the determination of the concentration of biological levels of polyhydroxylated compounds, particularly glucose. The methods utilize an amplification system that is an analyte transducer immobilized in a polymeric matrix, where the system is implantable and biocompatible. Upon interrogation by an optical system, the amplification system produces a signal capable of detection external to the skin of the patient. Quantitation of the analyte of interest is achieved by measurement of the emitted signal.

  4. Improvement of statistical methods for detecting anomalies in climate and environmental monitoring systems

    NASA Astrophysics Data System (ADS)

    Yakunin, A. G.; Hussein, H. M.

    2018-01-01

    The article shows how the known statistical methods, which are widely used in solving financial problems and a number of other fields of science and technology, can be effectively applied after minor modification for solving such problems in climate and environment monitoring systems, as the detection of anomalies in the form of abrupt changes in signal levels, the occurrence of positive and negative outliers and the violation of the cycle form in periodic processes.

  5. Detection of biological molecules using chemical amplification and optical sensors

    DOEpatents

    Van Antwerp, William Peter; Mastrototaro, John Joseph

    2004-10-12

    Methods are provided for the determination of the concentration of biological levels of polyhydroxylated compounds, particularly glucose. The methods utilize an amplification system that is an analyte transducer immobilized in a polymeric matrix, where the system is implantable and biocompatible. Upon interrogation by an optical system, the amplification system produces a signal capable of detection external to the skin of the patient. Quantitation of the analyte of interest is achieved by measurement of the emitted signal.

  6. A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

    PubMed

    Zhang, Qiyang; Maddukuri, Naveen; Gong, Maojun

    2015-10-02

    Cyanides are poisonous chemicals that widely exist in nature and industrial processes as well as accidental fires. Rapid and accurate determination of cyanide exposure would facilitate forensic investigation, medical diagnosis, and chronic cyanide monitoring. Here, a rapid and direct method was developed for the determination of cyanide ions in urinary samples. This technique was based on an integrated capillary electrophoresis system coupled with laser-induced fluorescence (LIF) detection. Cyanide ions were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and a primary amine (glycine) for LIF detection. Three separate reagents, NDA, glycine, and cyanide sample, were mixed online, which secured uniform conditions between samples for cyanide derivatization and reduced the risk of precipitation formation of mixtures. Conditions were optimized; the derivatization was completed in 2-4min, and the separation was observed in 25s. The limit of detection (LOD) was 4.0nM at 3-fold signal-to-noise ratio for standard cyanide in buffer. The cyanide levels in urine samples from smokers and non-smokers were determined by using the method of standard addition, which demonstrated significant difference of cyanide levels in urinary samples from the two groups of people. The developed method was rapid and accurate, and is anticipated to be applicable to cyanide detection in waste water with appropriate modification. Published by Elsevier B.V.

  7. Tracking wakefulness as it fades: Micro-measures of alertness.

    PubMed

    Jagannathan, Sridhar R; Ezquerro-Nassar, Alejandro; Jachs, Barbara; Pustovaya, Olga V; Bareham, Corinne A; Bekinschtein, Tristan A

    2018-08-01

    A major problem in psychology and physiology experiments is drowsiness: around a third of participants show decreased wakefulness despite being instructed to stay alert. In some non-visual experiments participants keep their eyes closed throughout the task, thus promoting the occurrence of such periods of varying alertness. These wakefulness changes contribute to systematic noise in data and measures of interest. To account for this omnipresent problem in data acquisition we defined criteria and code to allow researchers to detect and control for varying alertness in electroencephalography (EEG) experiments under eyes-closed settings. We first revise a visual-scoring method developed for detection and characterization of the sleep-onset process, and adapt the same for detection of alertness levels. Furthermore, we show the major issues preventing the practical use of this method, and overcome these issues by developing an automated method (micro-measures algorithm) based on frequency and sleep graphoelements, which are capable of detecting micro variations in alertness. The validity of the micro-measures algorithm was verified by training and testing using a dataset where participants are known to fall asleep. In addition, we tested generalisability by independent validation on another dataset. The methods developed constitute a unique tool to assess micro variations in levels of alertness and control trial-by-trial retrospectively or prospectively in every experiment performed with EEG in cognitive neuroscience under eyes-closed settings. Copyright © 2018. Published by Elsevier Inc.

  8. Remote photoplethysmography system for unsupervised monitoring regional anesthesia effectiveness

    NASA Astrophysics Data System (ADS)

    Rubins, U.; Miscuks, A.; Marcinkevics, Z.; Lange, M.

    2017-12-01

    Determining the level of regional anesthesia (RA) is vitally important to both an anesthesiologist and surgeon, also knowing the RA level can protect the patient and reduce the time of surgery. Normally to detect the level of RA, usually a simple subjective (sensitivity test) and complicated quantitative methods (thermography, neuromyography, etc.) are used, but there is not yet a standardized method for objective RA detection and evaluation. In this study, the advanced remote photoplethysmography imaging (rPPG) system for unsupervised monitoring of human palm RA is demonstrated. The rPPG system comprises compact video camera with green optical filter, surgical lamp as a light source and a computer with custom-developed software. The algorithm implemented in Matlab software recognizes the palm and two dermatomes (Medial and Ulnar innervation), calculates the perfusion map and perfusion changes in real-time to detect effect of RA. Seven patients (aged 18-80 years) undergoing hand surgery received peripheral nerve brachial plexus blocks during the measurements. Clinical experiments showed that our rPPG system is able to perform unsupervised monitoring of RA.

  9. Verifying the Presence of Low Levels of Neptunium in a Uranium Matrix with Electron Energy-Loss Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buck, Edgar C.; Douglas, Matthew; Wittman, Richard S.

    2010-01-01

    This paper examines the problems associated with the analysis of low levels of neptunium (Np) in a uranium (U) matrix with electron energy-loss spectroscopy (EELS) on the transmission electron microscope (TEM). The detection of Np in a matrix of uranium (U) can be impeded by the occurrence of a plural scattering event from U (U-M5 + U-O4,5) that results in severe overlap on the Np-M5 edge at 3665 eV. Low levels (1600 - 6300 ppm) of Np can be detected in U solids by confirming the energy gap between the Np-M5 and Np-M4 edges is at 184 eV and showingmore » that the M4/M5 ratio for the Np is smaller than that for U. The Richardson-Lucy deconvolution method was applied to energy-loss spectral images and was shown to increase the signal to noise. This method also improves the limits of detection for Np in a U matrix.« less

  10. Polyfluorinated substances in abiotic standard reference ...

    EPA Pesticide Factsheets

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781. Journal article published in Analytical and Bioanalytical Chemistry

  11. Polyfluorinated substances in abiotic standard reference materials.

    PubMed

    Reiner, Jessica L; Blaine, Andrea C; Higgins, Christopher P; Huset, Carin; Jenkins, Thomas M; Kwadijk, Christiaan J A F; Lange, Cleston C; Muir, Derek C G; Reagen, William K; Rich, Courtney; Small, Jeff M; Strynar, Mark J; Washington, John W; Yoo, Hoon; Keller, Jennifer M

    2015-04-01

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781.

  12. Dodging the cosmic curvature to probe the constancy of the speed of light

    NASA Astrophysics Data System (ADS)

    Cai, Rong-Gen; Guo, Zong-Kuan; Yang, Tao

    2016-08-01

    We develop a new model-independent method to probe the constancy of the speed of light c. In our method, the degeneracy between the cosmic curvature and the speed of light can be eliminated, which makes the test more natural and general. Combining the independent observations of Hubble parameter H(z) and luminosity distance dL(z), we use the model-independent smoothing technique, Gaussian processes, to reconstruct them and then detect variation of the speed of light. We find no signal of deviation from the present value of the speed of light c0. Moreover, to demonstrate the improvement in probing the constancy of the speed of light from future experiments, we produce a series of simulated data. The Dark Energy Survey will be able to detect Δc/c0 ~ 1% at ~ 1.5σ confidence level and Δc/c0 ~ 2% at ~ 3σ confidence level. If the errors are reduced to one-tenth of the expected DES ones, it can detect a Δc/c0 ~ 0.1% variation at ~ 2σ confidence level.

  13. Simultaneous determination of sulfonamides, tetracyclines and tiamulin in swine wastewater by solid-phase extraction and liquid chromatography-mass spectrometry.

    PubMed

    Ben, Weiwei; Qiang, Zhimin; Adams, Craig; Zhang, Heqing; Chen, Liping

    2008-08-22

    Little is known about the contamination level of antibiotics in swine wastewater in China. The highly complex matrix of swine wastewater, which generally has a chemical oxygen demand (COD) concentration as high as 15,000 mg/L, makes it difficult to detect antibiotics at trace levels. In this work, a highly selective and sensitive analytical method was developed for simultaneous determination of three classes of commonly used veterinary antibiotics including five sulfonamides, three tetracyclines and one macrolide in swine wastewater using solid-phase extraction (SPE) and liquid chromatography-mass spectrometry (LC-MS). The method detection limits (MDL) in the swine wastewater were determined to be between 5 and 91 ng/L, depending on specific antibiotics. Except sulfamethizole, all the other eight antibiotics were detected in the swine wastewaters collected from three concentrated swine feeding plants located in the Beijing (China) area, showing a concentration range of 0.62-32.67 microg/L. These results reveal the representative concentration levels of selected antibiotics in the swine wastewaters of Beijing area.

  14. Estimating the dose response relationship for occupational radiation exposure measured with minimum detection level.

    PubMed

    Xue, Xiaonan; Shore, Roy E; Ye, Xiangyang; Kim, Mimi Y

    2004-10-01

    Occupational exposures are often recorded as zero when the exposure is below the minimum detection level (BMDL). This can lead to an underestimation of the doses received by individuals and can lead to biased estimates of risk in occupational epidemiologic studies. The extent of the exposure underestimation is increased with the magnitude of the minimum detection level (MDL) and the frequency of monitoring. This paper uses multiple imputation methods to impute values for the missing doses due to BMDL. A Gibbs sampling algorithm is developed to implement the method, which is applied to two distinct scenarios: when dose information is available for each measurement (but BMDL is recorded as zero or some other arbitrary value), or when the dose information available represents the summation of a series of measurements (e.g., only yearly cumulative exposure is available but based on, say, weekly measurements). Then the average of the multiple imputed exposure realizations for each individual is used to obtain an unbiased estimate of the relative risk associated with exposure. Simulation studies are used to evaluate the performance of the estimators. As an illustration, the method is applied to a sample of historical occupational radiation exposure data from the Oak Ridge National Laboratory.

  15. Solid phase extraction of large volume of water and beverage samples to improve detection limits for GC-MS analysis of bisphenol A and four other bisphenols.

    PubMed

    Cao, Xu-Liang; Popovic, Svetlana

    2018-01-01

    Solid phase extraction (SPE) of large volumes of water and beverage products was investigated for the GC-MS analysis of bisphenol A (BPA), bisphenol AF (BPAF), bisphenol F (BPF), bisphenol E (BPE), and bisphenol B (BPB). While absolute recoveries of the method were improved for water and some beverage products (e.g. diet cola, iced tea), breakthrough may also have occurred during SPE of 200 mL of other beverages (e.g. BPF in cola). Improvements in method detection limits were observed with the analysis of large sample volumes for all bisphenols at ppt (pg/g) to sub-ppt levels. This improvement was found to be proportional to sample volumes for water and beverage products with less interferences and noise levels around the analytes. Matrix effects and interferences were observed during SPE of larger volumes (100 and 200 mL) of the beverage products, and affected the accurate analysis of BPF. This improved method was used to analyse bisphenols in various beverage samples, and only BPA was detected, with levels ranging from 0.022 to 0.030 ng/g for products in PET bottles, and 0.085 to 0.32 ng/g for products in cans.

  16. Viability qPCR, a new tool for Legionella risk management.

    PubMed

    Lizana, X; López, A; Benito, S; Agustí, G; Ríos, M; Piqué, N; Marqués, A M; Codony, F

    2017-11-01

    Viability quantitative Polymerase Chain Reaction (v-qPCR) is a recent analytical approach for only detecting live microorganisms by DNA amplification-based methods This approach is based on the use of a reagent that irreversibly fixes dead cells DNA. In this study, we evaluate the utility of v-qPCR versus culture method for Legionellosis risk management. The present study was performed using 116 real samples. Water samples were simultaneously analysed by culture, v-qPCR and qPCR methods. Results were compared by means of a non-parametric test. In 11.6% of samples using both methods (culture method and v-qPCR) results were positive, in 50.0% of samples both methods gave rise to negative results. As expected, equivalence between methods was not observed in all cases, as in 32.1% of samples positive results were obtained by v-qPCR and all of them gave rise to negative results by culture. Only in 6.3% of samples, with very low Legionella levels, was culture positive and v-qPCR negative. In 3.5% of samples, overgrowth of other bacteria did not allow performing the culture. When comparing both methods, significant differences between culture and v-qPCR were in the samples belonging to the cooling towers-evaporative condensers group. The v-qPCR method detected greater presence and obtained higher concentrations of Legionella spp. (p<0.001). Otherwise, no significant differences between methods were found in the rest of the groups. The v-qPCR method can be used as a quick tool to evaluate Legionellosis risk, especially in cooling towers-evaporative condensers, where this technique can detect higher levels than culture. The combined interpretation of PCR results along with the ratio of live cells is proposed as a tool for understanding the sample context and estimating the Legionellosis risk potential according to 4 levels of hierarchy. Copyright © 2017 Elsevier GmbH. All rights reserved.

  17. Express immunochromatographic detection of antibodies against Brucella abortus in cattle sera based on quantitative photometric registration and modulated cut-off level.

    PubMed

    Sotnikov, Dmitriy V; Byzova, Nadezhda A; Zherdev, Anatoly V; Eskendirova, Saule Z; Baltin, Kairat K; Mukanov, Kasim K; Ramankulov, Erlan M; Sadykhov, Elchin G; Dzantiev, Boris B

    2015-01-01

    An immunochromatographic test system was developed for rapid detection of the levels of specific IgG antibodies to Brucella abortus lipopolysaccharide, as a tool for diagnosis of brucellosis in cattle. The pilot test strips were examined using blood sera from sick (78 samples) and healthy (35 samples) cows. The results obtained by immunochromatographic assay, using a portable optical densitometer for digital video detection, correlate well with the results obtained by immunoenzyme assay and are in agreement with the results of the disease diagnosis. The new test system allows detection of antibodies within 10 min and can be proposed as an alternative to the methods available for serodiagnosis of brucellosis.

  18. HacDivSel: Two new methods (haplotype-based and outlier-based) for the detection of divergent selection in pairs of populations

    PubMed Central

    2017-01-01

    The detection of genomic regions involved in local adaptation is an important topic in current population genetics. There are several detection strategies available depending on the kind of genetic and demographic information at hand. A common drawback is the high risk of false positives. In this study we introduce two complementary methods for the detection of divergent selection from populations connected by migration. Both methods have been developed with the aim of being robust to false positives. The first method combines haplotype information with inter-population differentiation (FST). Evidence of divergent selection is concluded only when both the haplotype pattern and the FST value support it. The second method is developed for independently segregating markers i.e. there is no haplotype information. In this case, the power to detect selection is attained by developing a new outlier test based on detecting a bimodal distribution. The test computes the FST outliers and then assumes that those of interest would have a different mode. We demonstrate the utility of the two methods through simulations and the analysis of real data. The simulation results showed power ranging from 60–95% in several of the scenarios whilst the false positive rate was controlled below the nominal level. The analysis of real samples consisted of phased data from the HapMap project and unphased data from intertidal marine snail ecotypes. The results illustrate that the proposed methods could be useful for detecting locally adapted polymorphisms. The software HacDivSel implements the methods explained in this manuscript. PMID:28423003

  19. Colloidal-gold electrosensor measuring device

    DOEpatents

    Wegner, S.; Harpold, M.A.; McCaffrey, T.M.; Morris, S.E.; Wojciechowski, M.; Zhao, J.; Henkens, R.W.; Naser, N.; O`Daly, J.P.

    1995-11-21

    The present invention provides a new device for use in measuring lead levels in biological and environmental samples. Using square wave coulometry and colloidal gold particles impregnated on carbon electrodes, the present invention provides a rapid, reliable, portable and inexpensive means of detecting low lead levels. The colloidal gold modified electrodes have microelectrode array characteristics and produce significantly higher stripping detection signals for lead than are produced at bulk gold electrode surfaces. The method is effective in determining levels of lead down to at least 5 {micro}g/dL in blood samples as small as 10 {micro}L. 9 figs.

  20. Colloidal-gold electrosensor measuring device

    DOEpatents

    Wegner, Steven; Harpold, Michael A.; McCaffrey, Terence M.; Morris, Susan E.; Wojciechowski, Marek; Zhao, Junguo; Henkens, Robert W.; Naser, Najih; O'Daly, John P.

    1995-01-01

    The present invention provides a new device for use in measuring lead levels in biological and environmental samples. Using square wave coulometry and colloidal gold particles impregnated on carbon electrodes, the present invention provides a rapid, reliable, portable and inexpensive means of detecting low lead levels. The colloidal gold modified electrodes have microelectrode array characteristics and produce significantly higher stripping detection signals for lead than are produced at bulk gold electrode surfaces. The method is effective in determining levels of lead down to at least 5 .mu.g/dL in blood samples as small as 10 .mu.L.

  1. Reverse Transcription Quantitative Polymerase Chain Reaction for Detection of and Differentiation Between RNA and DNA of HIV-1-Based Lentiviral Vectors.

    PubMed

    Pavlovic, Melanie; Koehler, Nina; Anton, Martina; Dinkelmeier, Anna; Haase, Maren; Stellberger, Thorsten; Busch, Ulrich; Baiker, Armin E

    2017-08-01

    The purpose of the described method is the detection of and differentiation between RNA and DNA of human immunodeficiency virus (HIV)-derived lentiviral vectors (LV) in cell culture supernatants and swab samples. For the analytical surveillance of genetic engineering, operations methods for the detection of the HIV-1-based LV generations are required. Furthermore, for research issues, it is important to prove the absence of LV particles for downgrading experimental settings in terms of the biosafety level. Here, a quantitative polymerase chain reaction method targeting the long terminal repeat U5 subunit and the start sequence of the packaging signal ψ is described. Numerous controls are included in order to monitor the technical procedure.

  2. Miniprimer PCR, a New Lens for Viewing the Microbial World▿ †

    PubMed Central

    Isenbarger, Thomas A.; Finney, Michael; Ríos-Velázquez, Carlos; Handelsman, Jo; Ruvkun, Gary

    2008-01-01

    Molecular methods based on the 16S rRNA gene sequence are used widely in microbial ecology to reveal the diversity of microbial populations in environmental samples. Here we show that a new PCR method using an engineered polymerase and 10-nucleotide “miniprimers” expands the scope of detectable sequences beyond those detected by standard methods using longer primers and Taq polymerase. After testing the method in silico to identify divergent ribosomal genes in previously cloned environmental sequences, we applied the method to soil and microbial mat samples, which revealed novel 16S rRNA gene sequences that would not have been detected with standard primers. Deeply divergent sequences were discovered with high frequency and included representatives that define two new division-level taxa, designated CR1 and CR2, suggesting that miniprimer PCR may reveal new dimensions of microbial diversity. PMID:18083877

  3. GPS/DR Error Estimation for Autonomous Vehicle Localization.

    PubMed

    Lee, Byung-Hyun; Song, Jong-Hwa; Im, Jun-Hyuck; Im, Sung-Hyuck; Heo, Moon-Beom; Jee, Gyu-In

    2015-08-21

    Autonomous vehicles require highly reliable navigation capabilities. For example, a lane-following method cannot be applied in an intersection without lanes, and since typical lane detection is performed using a straight-line model, errors can occur when the lateral distance is estimated in curved sections due to a model mismatch. Therefore, this paper proposes a localization method that uses GPS/DR error estimation based on a lane detection method with curved lane models, stop line detection, and curve matching in order to improve the performance during waypoint following procedures. The advantage of using the proposed method is that position information can be provided for autonomous driving through intersections, in sections with sharp curves, and in curved sections following a straight section. The proposed method was applied in autonomous vehicles at an experimental site to evaluate its performance, and the results indicate that the positioning achieved accuracy at the sub-meter level.

  4. GPS/DR Error Estimation for Autonomous Vehicle Localization

    PubMed Central

    Lee, Byung-Hyun; Song, Jong-Hwa; Im, Jun-Hyuck; Im, Sung-Hyuck; Heo, Moon-Beom; Jee, Gyu-In

    2015-01-01

    Autonomous vehicles require highly reliable navigation capabilities. For example, a lane-following method cannot be applied in an intersection without lanes, and since typical lane detection is performed using a straight-line model, errors can occur when the lateral distance is estimated in curved sections due to a model mismatch. Therefore, this paper proposes a localization method that uses GPS/DR error estimation based on a lane detection method with curved lane models, stop line detection, and curve matching in order to improve the performance during waypoint following procedures. The advantage of using the proposed method is that position information can be provided for autonomous driving through intersections, in sections with sharp curves, and in curved sections following a straight section. The proposed method was applied in autonomous vehicles at an experimental site to evaluate its performance, and the results indicate that the positioning achieved accuracy at the sub-meter level. PMID:26307997

  5. Real-time Series Resistance Monitoring in PV Systems; NREL (National Renewable Energy Laboratory)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deceglie, M. G.; Silverman, T. J.; Marion, B.

    We apply the physical principles of a familiar method, suns-Voc, to a new application: the real-time detection of series resistance changes in modules and systems operating outside. The real-time series resistance (RTSR) method that we describe avoids the need for collecting IV curves or constructing full series-resistance-free IV curves. RTSR is most readily deployable at the module level on apply the physical principles of a familiar method, suns-Voc, to a new application: the real-time detection of series resistance changes in modules and systems operating outside. The real-time series resistance (RTSR) method that we describe avoids the need for collecting IVmore » curves or constructing full series-resistance-free IV curves. RTSR is most readily deployable at the module level on micro-inverters or module-integrated electronics, but it can also be extended to full strings. Automated detection of series resistance increases can provide early warnings of some of the most common reliability issues, which also pose fire risks, including broken ribbons, broken solder bonds, and contact problems in the junction or combiner box. We describe the method in detail and describe a sample application to data collected from modules operating in the field.« less

  6. Evaluating image reconstruction methods for tumor detection performance in whole-body PET oncology imaging

    NASA Astrophysics Data System (ADS)

    Lartizien, Carole; Kinahan, Paul E.; Comtat, Claude; Lin, Michael; Swensson, Richard G.; Trebossen, Regine; Bendriem, Bernard

    2000-04-01

    This work presents initial results from observer detection performance studies using the same volume visualization software tools that are used in clinical PET oncology imaging. Research into the FORE+OSEM and FORE+AWOSEM statistical image reconstruction methods tailored to whole- body 3D PET oncology imaging have indicated potential improvements in image SNR compared to currently used analytic reconstruction methods (FBP). To assess the resulting impact of these reconstruction methods on the performance of human observers in detecting and localizing tumors, we use a non- Monte Carlo technique to generate multiple statistically accurate realizations of 3D whole-body PET data, based on an extended MCAT phantom and with clinically realistic levels of statistical noise. For each realization, we add a fixed number of randomly located 1 cm diam. lesions whose contrast is varied among pre-calibrated values so that the range of true positive fractions is well sampled. The observer is told the number of tumors and, similar to the AFROC method, asked to localize all of them. The true positive fraction for the three algorithms (FBP, FORE+OSEM, FORE+AWOSEM) as a function of lesion contrast is calculated, although other protocols could be compared. A confidence level for each tumor is also recorded for incorporation into later AFROC analysis.

  7. Inflight Microbial Monitoring- An Alternative Method to Culture Based Detection Currently Used on the International Space Station

    NASA Technical Reports Server (NTRS)

    Khodadad, Christina L.; Birmele, Michele N.; Roman, Monsi; Hummerick, Mary E.; Smith, David J.; Wheeler, Raymond M.

    2015-01-01

    Previous research has shown that potentially destructive microorganisms and human pathogens have been detected on the International Space Station (ISS). The likelihood of introducing new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of the total microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS microbes requires that samples be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.

  8. Inflight Microbial Monitoring-An Alternative Method to Culture Based Detection Currently Used on International Space Station

    NASA Technical Reports Server (NTRS)

    Khodadad, Christina L.; Birmele, Michele N.; Roman, Monsi; Hummerick, Mary E.; Smith, David J.; Wheeler, Raymond M.

    2015-01-01

    Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS). The potential to introduce new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Previous research has shown that microorganisms introduced to the ISS are readily transferred between crew and subsystems and back (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and a 48-hour incubation time. This increases the microbial load while detecting a limited number of microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification, To identify and enumerate ISS samples requires that samples to be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganism at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.

  9. TU-EF-204-03: Task-Based KV and MAs Optimization for Radiation Dose Reduction in CT: From FBP to Statistical Model-Based Iterative Reconstruction (MBIR)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gomez-Cardona, D; Li, K; Lubner, M G

    Purpose: The introduction of the highly nonlinear MBIR algorithm to clinical CT systems has made CNR an invalid metric for kV optimization. The purpose of this work was to develop a task-based framework to unify kV and mAs optimization for both FBP- and MBIR-based CT systems. Methods: The kV-mAs optimization was formulated as a constrained minimization problem: to select kV and mAs to minimize dose under the constraint of maintaining the detection performance as clinically prescribed. To experimentally solve this optimization problem, exhaustive measurements of detectability index (d’) for a hepatic lesion detection task were performed at 15 different mAmore » levels and 4 kV levels using an anthropomorphic phantom. The measured d’ values were used to generate an iso-detectability map; similarly, dose levels recorded at different kV-mAs combinations were used to generate an iso-dose map. The iso-detectability map was overlaid on top of the iso-dose map so that for a prescribed detectability level d’, the optimal kV-mA can be determined from the crossing between the d’ contour and the dose contour that corresponds to the minimum dose. Results: Taking d’=16 as an example: the kV-mAs combinations on the measured iso-d’ line of MBIR are 80–150 (3.8), 100–140 (6.6), 120–150 (11.3), and 140–160 (17.2), where values in the parentheses are measured dose values. As a Result, the optimal kV was 80 and optimal mA was 150. In comparison, the optimal kV and mA for FBP were 100 and 500, which corresponded to a dose level of 24 mGy. Results of in vivo animal experiments were consistent with the phantom results. Conclusion: A new method to optimize kV and mAs selection has been developed. This method is applicable to both linear and nonlinear CT systems such as those using MBIR. Additional dose savings can be achieved by combining MBIR with this method. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona, M. G. Lubner: Nothing to disclose. P. J. Pickhardt: Co-founder, VirtuoCTC, LLC Stockholder, Cellectar Biosciences, Inc. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX.« less

  10. Benzimidazole derivatives: selective fluorescent chemosensors for the picogram detection of picric acid.

    PubMed

    Xiong, Jin-Feng; Li, Jian-Xiao; Mo, Guang-Zhen; Huo, Jing-Pei; Liu, Jin-Yan; Chen, Xiao-Yun; Wang, Zhao-Yang

    2014-12-05

    1,3,5-Tri(1H-benzo[d]imidazol-2-yl)benzene derivatives, as a new kind of fluorescent chemosensor for the detection of nitroaromatic explosives, are designed and synthesized by simple N-hydrocarbylation. Among 16 obtained compounds, compound 4g has the best capability for detection of picric acid (PA), having good selectivity and high sensitivity. The detection of PA with 4g solution-coated paper strips at the picogram level is developed. A simple, portable, and low-cost method is provided for detecting PA in solution and contact mode.

  11. An image cytometric technique is a concise method to detect adenoviruses and host cell proteins and to monitor the infection and cellular responses induced.

    PubMed

    Morinaga, Takao; Nguyễn, Thảo Thi Thanh; Zhong, Boya; Hanazono, Michiko; Shingyoji, Masato; Sekine, Ikuo; Tada, Yuji; Tatsumi, Koichiro; Shimada, Hideaki; Hiroshima, Kenzo; Tagawa, Masatoshi

    2017-11-10

    Genetically modified adenoviruses (Ad) with preferential replications in tumor cells have been examined for a possible clinical applicability as an anti-cancer agent. A simple method to detect viral and cellular proteins is valuable to monitor the viral infections and to predict the Ad-mediated cytotoxicity. We used type 5 Ad in which the expression of E1A gene was activated by 5'-regulatory sequences of genes that were augmented in the expression in human tumors. The Ad were further modified to have the fiber-knob region replaced with that derived from type 35 Ad. We infected human mesothelioma cells with the fiber-replaced Ad, and sequentially examined cytotoxic processes together with an expression level of the viral E1A, hexon, and cellular cleaved caspase-3 with image cytometric and Western blot analyses. The replication-competent Ad produced cytotoxicity on mesothelioma cells. The infected cells expressed E1A and hexon 24 h after the infection and then showed cleavage of caspase-3, all of which were detected with image cytometry and Western blot analysis. Image cytometry furthermore demonstrated that increased Ad doses did not enhance an expression level of E1A and hexon in an individual cell and that caspase-3-cleaved cells were found more frequently in hexon-positive cells than in E1A-positive cells. Image cytometry thus detected these molecular changes in a sensitive manner and at a single cell level. We also showed that an image cytometric technique detected expression changes of other host cell proteins, cyclin-E and phosphorylated histone H3 at a single cell level. Image cytometry is a concise procedure to detect expression changes of Ad and host cell proteins at a single cell level, and is useful to analyze molecular events after the infection.

  12. Detecting Circular RNAs by RNA Fluorescence In Situ Hybridization.

    PubMed

    Zirkel, Anne; Papantonis, Argyris

    2018-01-01

    Fluorescence in situ hybridization (FISH) coupled to high-resolution microscopy is a powerful method for analyzing the subcellular localization of RNA. However, the detection of circular RNAs (circRNAs) using microscopy is challenging because the only feature of a circRNA that can be used for the probe design is its junction. Circular RNAs are expressed at varying levels, and for their efficient monitoring by FISH, background fluorescence levels need to be kept low. Here, we describe a FISH protocol coupled to high-precision localizations using a single fluorescently labeled probe spanning the circRNA junction; this allows circRNA detection in mammalian cells with high signal-to-noise ratios.

  13. Probabilistic model for quick detection of dissimilar binary images

    NASA Astrophysics Data System (ADS)

    Mustafa, Adnan A. Y.

    2015-09-01

    We present a quick method to detect dissimilar binary images. The method is based on a "probabilistic matching model" for image matching. The matching model is used to predict the probability of occurrence of distinct-dissimilar image pairs (completely different images) when matching one image to another. Based on this model, distinct-dissimilar images can be detected by matching only a few points between two images with high confidence, namely 11 points for a 99.9% successful detection rate. For image pairs that are dissimilar but not distinct-dissimilar, more points need to be mapped. The number of points required to attain a certain successful detection rate or confidence depends on the amount of similarity between the compared images. As this similarity increases, more points are required. For example, images that differ by 1% can be detected by mapping fewer than 70 points on average. More importantly, the model is image size invariant; so, images of any sizes will produce high confidence levels with a limited number of matched points. As a result, this method does not suffer from the image size handicap that impedes current methods. We report on extensive tests conducted on real images of different sizes.

  14. Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahl, Karen L.; Colburn, Heather A.; Wunschel, David S.

    2010-02-15

    Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and notmore » in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.« less

  15. Simultaneous analysis of vascular norepinephrine and ATP release using an integrated microfluidic system.

    PubMed

    Townsend, Alexandra D; Wilken, Gerald H; Mitchell, Kyle K; Martin, R Scott; Macarthur, Heather

    2016-06-15

    Sympathetic nerves are known to release three neurotransmitters: norepinephrine, ATP, and neuropeptide Y that play a role in controlling vascular tone. This paper focuses on the co-release of norepinephrine and ATP from the mesenteric arterial sympathetic nerves of the rat. In this paper, a quantification technique is described that allows simultaneous detection of norepinephrine and ATP in a near-real-time fashion from the isolated perfused mesenteric arterial bed of the rat. Simultaneous detection is enabled with 3-D printing technology, which is shown to help integrate the perfusate with different detection methods (norepinephrine by microchip-based amperometery and ATP by on-line chemiluminescence). Stimulated levels relative to basal levels of norepinephrine and ATP were found to be 363nM and 125nM, respectively (n=6). The limit of detection for norepinephrine is 80nM using microchip-based amperometric detection. The LOD for on-line ATP detection using chemiluminescence is 35nM. In previous studies, the co-transmitters have been separated and detected with HPLC techniques. With HPLC, the samples from biological preparations have to be derivatized for ATP detection and require collection time before analysis. Thus real-time measurements are not made and the delay in analysis by HPLC can cause degradation. In conclusion, the method described in the paper can be used to successfully detect norepinephrine and ATP simultaneously and in a near-real-time fashion. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Peptide Peak Detection for Low Resolution MALDI-TOF Mass Spectrometry.

    PubMed

    Yao, Jingwen; Utsunomiya, Shin-Ichi; Kajihara, Shigeki; Tabata, Tsuyoshi; Aoshima, Ken; Oda, Yoshiya; Tanaka, Koichi

    2014-01-01

    A new peak detection method has been developed for rapid selection of peptide and its fragment ion peaks for protein identification using tandem mass spectrometry. The algorithm applies classification of peak intensities present in the defined mass range to determine the noise level. A threshold is then given to select ion peaks according to the determined noise level in each mass range. This algorithm was initially designed for the peak detection of low resolution peptide mass spectra, such as matrix-assisted laser desorption/ionization Time-of-Flight (MALDI-TOF) mass spectra. But it can also be applied to other type of mass spectra. This method has demonstrated obtaining a good rate of number of real ions to noises for even poorly fragmented peptide spectra. The effect of using peak lists generated from this method produces improved protein scores in database search results. The reliability of the protein identifications is increased by finding more peptide identifications. This software tool is freely available at the Mass++ home page (http://www.first-ms3d.jp/english/achievement/software/).

  17. Peptide Peak Detection for Low Resolution MALDI-TOF Mass Spectrometry

    PubMed Central

    Yao, Jingwen; Utsunomiya, Shin-ichi; Kajihara, Shigeki; Tabata, Tsuyoshi; Aoshima, Ken; Oda, Yoshiya; Tanaka, Koichi

    2014-01-01

    A new peak detection method has been developed for rapid selection of peptide and its fragment ion peaks for protein identification using tandem mass spectrometry. The algorithm applies classification of peak intensities present in the defined mass range to determine the noise level. A threshold is then given to select ion peaks according to the determined noise level in each mass range. This algorithm was initially designed for the peak detection of low resolution peptide mass spectra, such as matrix-assisted laser desorption/ionization Time-of-Flight (MALDI-TOF) mass spectra. But it can also be applied to other type of mass spectra. This method has demonstrated obtaining a good rate of number of real ions to noises for even poorly fragmented peptide spectra. The effect of using peak lists generated from this method produces improved protein scores in database search results. The reliability of the protein identifications is increased by finding more peptide identifications. This software tool is freely available at the Mass++ home page (http://www.first-ms3d.jp/english/achievement/software/). PMID:26819872

  18. Rapid determination of benzo(a)pyrene in roasted coffee and coffee brew by high-performance liquid chromatography with fluorescence detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Kruijf, N.; Schouten, T.; van der Stegen, G.H.D.

    A rapid and reliable analytical method is presented for the determination of trace amounts of benzo(a)pyrene in roasted coffee, coffee brew, and spent grounds. Roasted coffee and spent grounds were extracted with acetone, followed by saponification and cyclohexane extraction. Coffee brew was extracted three times with cyclohexane, and the combined extracts were purified by chromatography on a silica gel column. The extracts were analyzed by HPLC with a 5-..mu..m Vydac reversed-phase 201 TPB 5 column and fluorescence detection under isocratic conditions. The benzo(a)pyrene levels in 55 roasted coffee samples, commercially available in the Netherlands, ranged from not detectable (<0.1 ..mu..g/kg)more » to 0.5 ..mu..g/kg. Coffee brews were prepared by two different methods from an over-roasted coffee sample with an elevated benzo(a)pyrene level of 2 ..mu..g/kg. These brews yielded benzo(a)pyrene contents of approximately 1 ng/L, indicating benzo(a)pyrene extraction yields of about 1% for both coffee preparation methods.« less

  19. Method for selective detection of explosives in mass spectrometer or ion mobility spectrometer at parts-per-quadrillion level

    DOEpatents

    Ewing, Robert G.; Atkinson, David A.; Clowers, Brian H.

    2015-09-01

    A method for selective detection of volatile and non-volatile explosives in a mass spectrometer or ion mobility spectrometer at a parts-per-quadrillion level without preconcentration is disclosed. The method comprises the steps of ionizing a carrier gas with an ionization source to form reactant ions or reactant adduct ions comprising nitrate ions (NO.sub.3.sup.-); selectively reacting the reactant ions or reactant adduct ions with at least one volatile or non-volatile explosive analyte at a carrier gas pressure of at least about 100 Ton in a reaction region disposed between the ionization source and an ion detector, the reaction region having a length which provides a residence time (tr) for reactant ions therein of at least about 0.10 seconds, wherein the selective reaction yields product ions comprising reactant ions or reactant adduct ions that are selectively bound to the at least one explosive analyte when present therein; and detecting product ions with the ion detector to determine presence or absence of the at least one explosive analyte.

  20. Breast mass segmentation in mammography using plane fitting and dynamic programming.

    PubMed

    Song, Enmin; Jiang, Luan; Jin, Renchao; Zhang, Lin; Yuan, Yuan; Li, Qiang

    2009-07-01

    Segmentation is an important and challenging task in a computer-aided diagnosis (CAD) system. Accurate segmentation could improve the accuracy in lesion detection and characterization. The objective of this study is to develop and test a new segmentation method that aims at improving the performance level of breast mass segmentation in mammography, which could be used to provide accurate features for classification. This automated segmentation method consists of two main steps and combines the edge gradient, the pixel intensity, as well as the shape characteristics of the lesions to achieve good segmentation results. First, a plane fitting method was applied to a background-trend corrected region-of-interest (ROI) of a mass to obtain the edge candidate points. Second, dynamic programming technique was used to find the "optimal" contour of the mass from the edge candidate points. Area-based similarity measures based on the radiologist's manually marked annotation and the segmented region were employed as criteria to evaluate the performance level of the segmentation method. With the evaluation criteria, the new method was compared with 1) the dynamic programming method developed by Timp and Karssemeijer, and 2) the normalized cut segmentation method, based on 337 ROIs extracted from a publicly available image database. The experimental results indicate that our segmentation method can achieve a higher performance level than the other two methods, and the improvements in segmentation performance level were statistically significant. For instance, the mean overlap percentage for the new algorithm was 0.71, whereas those for Timp's dynamic programming method and the normalized cut segmentation method were 0.63 (P < .001) and 0.61 (P < .001), respectively. We developed a new segmentation method by use of plane fitting and dynamic programming, which achieved a relatively high performance level. The new segmentation method would be useful for improving the accuracy of computerized detection and classification of breast cancer in mammography.

  1. Computer-aided detection of bladder mass within non-contrast-enhanced region of CT Urography (CTU)

    NASA Astrophysics Data System (ADS)

    Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon; Zhou, Chuan

    2016-03-01

    We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). We have previously developed methods for detection of bladder masses within the contrast-enhanced region of the bladder. In this study, we investigated methods for detection of bladder masses within the non-contrast enhanced region. The bladder was first segmented using a newly developed deep-learning convolutional neural network in combination with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensityprojection- based method. The non-contrast region was smoothed and a gray level threshold was employed to segment the bladder wall and potential masses. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify lesion candidates as a prescreening step. The lesion candidates were segmented using our autoinitialized cascaded level set (AI-CALS) segmentation method, and 27 morphological features were extracted for each candidate. Stepwise feature selection with simplex optimization and leave-one-case-out resampling were used for training and validation of a false positive (FP) classifier. In each leave-one-case-out cycle, features were selected from the training cases and a linear discriminant analysis (LDA) classifier was designed to merge the selected features into a single score for classification of the left-out test case. A data set of 33 cases with 42 biopsy-proven lesions in the noncontrast enhanced region was collected. During prescreening, the system obtained 83.3% sensitivity at an average of 2.4 FPs/case. After feature extraction and FP reduction by LDA, the system achieved 81.0% sensitivity at 2.0 FPs/case, and 73.8% sensitivity at 1.5 FPs/case.

  2. Optical Reflectance and Fluorescence for Detecting Nitrogen Needs in Zea mays L.

    NASA Technical Reports Server (NTRS)

    McMurtrey, J. E.; Middleton, E. M.; Corp. L. A.; Campbell, P. K. Entcheva; Butcher, L. M.; Daughtry, C. S. T.

    2003-01-01

    Nitrogen (N) status in field grown corn (Zea mays L.) was assessed using spectral techniques. Passive reflectance remote sensing and, both passive and active fluorescence sensing methods were investigated. Reflectance and fluorescence methods are reported to detect changes in the primary plant pigments (chlorophylls a and b; carotenoids) in higher plant species. As a general rule, foliar chlorophyll a (Chl a) and chlorophyll b (Chl b) usually exist in approx.3:l ratio. In plants under stress, Chl b content is affected before Chl a reductions occur. For reflectance, a version of the chlorophyll absorption in reflectance index (CARI) method was tested with narrow bands from the Airborne Imaging Spectroradiometer for Applications (ASIA). CARI minimizes the effects of soil background on the signal from green canopies. A modified CARI (MCARI) was used to track total Chl a levels in the red dip of the spectrum from the corn canopy. A second MCARI was used to track the auxiliary plant pigments (Chl b and the carotenoids) in the yellow/orange/red edge part of the reflectance spectrum. The difference between these two MCARI indices detected variations in N levels across the field plot canopies using ASIA data. At the leaf level, ratios of fluorescence emissions in the blue, green, red and far-red wavelengths sensed responses that were associated with the plant pigments, and were indicative of energy transfer in the photosynthetic process. N stressed corn stands could be distinguish from those with optimally applied N with fluorescence emission spectra obtained from individual corn leaves. Both reflectance and fluorescence methods are sensitive in detecting corn N needs and may be especially powerful in monitoring crop conditions if both types of information can be combined.

  3. [A computer tomography assisted method for the automatic detection of region of interest in dynamic kidney images].

    PubMed

    Jing, Xueping; Zheng, Xiujuan; Song, Shaoli; Liu, Kai

    2017-12-01

    Glomerular filtration rate (GFR), which can be estimated by Gates method with dynamic kidney single photon emission computed tomography (SPECT) imaging, is a key indicator of renal function. In this paper, an automatic computer tomography (CT)-assisted detection method of kidney region of interest (ROI) is proposed to achieve the objective and accurate GFR calculation. In this method, the CT coronal projection image and the enhanced SPECT synthetic image are firstly generated and registered together. Then, the kidney ROIs are delineated using a modified level set algorithm. Meanwhile, the background ROIs are also obtained based on the kidney ROIs. Finally, the value of GFR is calculated via Gates method. Comparing with the clinical data, the GFR values estimated by the proposed method were consistent with the clinical reports. This automatic method can improve the accuracy and stability of kidney ROI detection for GFR calculation, especially when the kidney function has been severely damaged.

  4. Convolutional neural network features based change detection in satellite images

    NASA Astrophysics Data System (ADS)

    Mohammed El Amin, Arabi; Liu, Qingjie; Wang, Yunhong

    2016-07-01

    With the popular use of high resolution remote sensing (HRRS) satellite images, a huge research efforts have been placed on change detection (CD) problem. An effective feature selection method can significantly boost the final result. While hand-designed features have proven difficulties to design features that effectively capture high and mid-level representations, the recent developments in machine learning (Deep Learning) omit this problem by learning hierarchical representation in an unsupervised manner directly from data without human intervention. In this letter, we propose approaching the change detection problem from a feature learning perspective. A novel deep Convolutional Neural Networks (CNN) features based HR satellite images change detection method is proposed. The main guideline is to produce a change detection map directly from two images using a pretrained CNN. This method can omit the limited performance of hand-crafted features. Firstly, CNN features are extracted through different convolutional layers. Then, a concatenation step is evaluated after an normalization step, resulting in a unique higher dimensional feature map. Finally, a change map was computed using pixel-wise Euclidean distance. Our method has been validated on real bitemporal HRRS satellite images according to qualitative and quantitative analyses. The results obtained confirm the interest of the proposed method.

  5. A speeded-up saliency region-based contrast detection method for small targets

    NASA Astrophysics Data System (ADS)

    Li, Zhengjie; Zhang, Haiying; Bai, Jiaojiao; Zhou, Zhongjun; Zheng, Huihuang

    2018-04-01

    To cope with the rapid development of the real applications for infrared small targets, the researchers have tried their best to pursue more robust detection methods. At present, the contrast measure-based method has become a promising research branch. Following the framework, in this paper, a speeded-up contrast measure scheme is proposed based on the saliency detection and density clustering. First, the saliency region is segmented by saliency detection method, and then, the Multi-scale contrast calculation is carried out on it instead of traversing the whole image. Second, the target with a certain "integrity" property in spatial is exploited to distinguish the target from the isolated noises by density clustering. Finally, the targets are detected by a self-adaptation threshold. Compared with time-consuming MPCM (Multiscale Patch Contrast Map), the time cost of the speeded-up version is within a few seconds. Additional, due to the use of "clustering segmentation", the false alarm caused by heavy noises can be restrained to a lower level. The experiments show that our method has a satisfied FASR (False alarm suppression ratio) and real-time performance compared with the state-of-art algorithms no matter in cloudy sky or sea-sky background.

  6. Absolute quantification of DNA methylation using microfluidic chip-based digital PCR.

    PubMed

    Wu, Zhenhua; Bai, Yanan; Cheng, Zule; Liu, Fangming; Wang, Ping; Yang, Dawei; Li, Gang; Jin, Qinghui; Mao, Hongju; Zhao, Jianlong

    2017-10-15

    Hypermethylation of CpG islands in the promoter region of many tumor suppressor genes downregulates their expression and in a result promotes tumorigenesis. Therefore, detection of DNA methylation status is a convenient diagnostic tool for cancer detection. Here, we reported a novel method for the integrative detection of methylation by the microfluidic chip-based digital PCR. This method relies on methylation-sensitive restriction enzyme HpaII, which cleaves the unmethylated DNA strands while keeping the methylated ones intact. After HpaII treatment, the DNA methylation level is determined quantitatively by the microfluidic chip-based digital PCR with the lower limit of detection equal to 0.52%. To validate the applicability of this method, promoter methylation of two tumor suppressor genes (PCDHGB6 and HOXA9) was tested in 10 samples of early stage lung adenocarcinoma and their adjacent non-tumorous tissues. The consistency was observed in the analysis of these samples using our method and a conventional bisulfite pyrosequencing. Combining high sensitivity and low cost, the microfluidic chip-based digital PCR method might provide a promising alternative for the detection of DNA methylation and early diagnosis of epigenetics-related diseases. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Ultra-sensitive in-situ detection of near-infrared persistent luminescent tracer nanoagents in crude oil-water mixtures.

    PubMed

    Chuang, Yen-Jun; Liu, Feng; Wang, Wei; Kanj, Mazen Y; Poitzsch, Martin E; Pan, Zhengwei

    2016-06-15

    Current fluorescent nanoparticles-based tracer sensing techniques for oilfield applications suffer from insufficient sensitivity, with the tracer detection limit typically at the several hundred ppm level in untreated oil/water mixtures, which is mainly caused by the interference of the background fluorescence from the organic residues in crude oil under constant external excitation. Here we report the use of a persistent luminescence phenomenon, which enables an external excitation-free and thus background fluorescence-free measurement condition, for ultrahigh-sensitivity crude oil sensing. By using LiGa5O8:Cr(3+) near-infrared persistent luminescent nanoparticles as a tracer nanoagent, we achieved a tracer detection limit at the single-digit ppb level (down to 1 ppb concentration of nanoparticles) in high oil fraction (up to 65 wt.%) oil/water mixtures via a convenient, CCD camera-based imaging technique without any pretreatment or phase separation of the fluid samples. This detection limit is about four to five orders of magnitude lower than that obtained using conventional spectral methods. This study introduces a new type of tracer nanoagents and a new detection method for water tracer sensing in oil reservoir characterization and management.

  8. Detecting subsurface fluid leaks in real-time using injection and production rates

    NASA Astrophysics Data System (ADS)

    Singh, Harpreet; Huerta, Nicolas J.

    2017-12-01

    CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to detecting the time when a leak is activated and the volume of that leakage, this method provides an insight about the leak location, and reservoir connectivity. We are proposing this as a complementary method that can be used with other, more expensive, methods early on in the injection process. This will allow an operator to conduct more expensive surveys less often because the proposed method can show if there are no leaks on a monthly basis that is cheap and fast.

  9. Deception Detection: Accuracy Levels Among International Military Officers Using Content and Contextual Questioning Methods

    DTIC Science & Technology

    2016-12-01

    average, people are slightly better than fifty-fifty at detecting deception, as seen in a published Personality and Social Psychology Review article...at detecting deception, as seen in a published Personality and Social Psychology Review article. Modern research ideology favors using diagnostic... psychological factors such as mood, temperament, or any other conditions [that] might affect participants’ responses.” Also, participants in the current

  10. Beat frequency ultrasonic microsphere contrast agent detection system

    NASA Technical Reports Server (NTRS)

    Pretlow, Robert A., III (Inventor); Yost, William T. (Inventor); Cantrell, John H., Jr. (Inventor)

    1995-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  11. Beat frequency ultrasonic microsphere contrast agent detection system

    NASA Technical Reports Server (NTRS)

    Pretlow, III, Robert A. (Inventor); Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)

    1997-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  12. Substantial Expansion of Detectable Size Range in Ionic Current Sensing through Pores by Using a Microfluidic Bridge Circuit.

    PubMed

    Yasaki, Hirotoshi; Yasui, Takao; Yanagida, Takeshi; Kaji, Noritada; Kanai, Masaki; Nagashima, Kazuki; Kawai, Tomoji; Baba, Yoshinobu

    2017-10-11

    Measuring ionic currents passing through nano- or micropores has shown great promise for the electrical discrimination of various biomolecules, cells, bacteria, and viruses. However, conventional measurements have shown there is an inherent limitation to the detectable particle volume (1% of the pore volume), which critically hinders applications to real mixtures of biomolecule samples with a wide size range of suspended particles. Here we propose a rational methodology that can detect samples with the detectable particle volume of 0.01% of the pore volume by measuring a transient current generated from the potential differences in a microfluidic bridge circuit. Our method substantially suppresses the background ionic current from the μA level to the pA level, which essentially lowers the detectable particle volume limit even for relatively large pore structures. Indeed, utilizing a microscale long pore structure (volume of 5.6 × 10 4 aL; height and width of 2.0 × 2.0 μm; length of 14 μm), we successfully detected various samples including polystyrene nanoparticles (volume: 4 aL), bacteria, cancer cells, and DNA molecules. Our method will expand the applicability of ionic current sensing systems for various mixed biomolecule samples with a wide size range, which have been difficult to measure by previously existing pore technologies.

  13. Nano-biosensors to detect beta-amyloid for Alzheimer's disease management.

    PubMed

    Kaushik, Ajeet; Jayant, Rahul Dev; Tiwari, Sneham; Vashist, Arti; Nair, Madhavan

    2016-06-15

    Beta-amyloid (β-A) peptides are potential biomarkers to monitor Alzheimer's diseases (AD) for diagnostic purposes. Increased β-A level is neurotoxic and induces oxidative stress in brain resulting in neurodegeneration and causes dementia. As of now, no sensitive and inexpensive method is available for β-A detection under physiological and pathological conditions. Although, available methods such as neuroimaging, enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR) detect β-A, but they are not yet extended at point-of-care (POC) due to sophisticated equipments, need of high expertize, complicated operations, and challenge of low detection limit. Recently, β-A antibody based electrochemical immuno-sensing approach has been explored to detect β-A at pM levels within 30-40 min compared to 6-8h of ELISA test. The introduction of nano-enabling electrochemical sensing technology could enable rapid detection of β-A at POC and may facilitate fast personalized health care delivery. This review explores recent advancements in nano-enabling electrochemical β-A sensing technologies towards POC application to AD management. These analytical tools can serve as an analytical tool for AD management program to obtain bio-informatics needed to optimize therapeutics for neurodegenerative diseases diagnosis management. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Optical detection of special nuclear materials: an alternative approach for standoff and remote sensing

    NASA Astrophysics Data System (ADS)

    Johnson, J. Bruce; Reeve, S. W.; Burns, W. A.; Allen, Susan D.

    2010-04-01

    Termed Special Nuclear Material (SNM) by the Atomic Energy Act of 1954, fissile materials, such as 235U and 239Pu, are the primary components used to construct modern nuclear weapons. Detecting the clandestine presence of SNM represents an important capability for Homeland Security. An ideal SNM sensor must be able to detect fissile materials present at ppb levels, be able to distinguish between the source of the detected fissile material, i.e., 235U, 239Pu, 233U or other fission source, and be able to perform the discrimination in near real time. A sensor with such capabilities would provide not only rapid identification of a threat but, ultimately, information on the potential source of the threat. For example, current detection schemes for monitoring clandestine nuclear testing and nuclear fuel reprocessing to provide weapons grade fissile material rely largely on passive air sampling combined with a subsequent instrumental analysis or some type of wet chemical analysis of the collected material. It would be highly useful to have a noncontact method of measuring isotopes capable of providing forensic information rapidly at ppb levels of detection. Here we compare the use of Kr, Xe and I as "canary" species for distinguishing between 235U and 239Pu fission sources by spectroscopic methods.

  15. A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients

    PubMed Central

    Al-Khayat, Mohammad Ammar; Karabet, Francois; Al-Mardini, Mohammad Amer

    2018-01-01

    Formaldehyde is a highly reactive impurity that can be found in many pharmaceutical excipients. Trace levels of this impurity may affect drug product stability, safety, efficacy, and performance. A static headspace gas chromatographic method was developed and validated to determine formaldehyde in pharmaceutical excipients after an effective derivatization procedure using acidified ethanol. Diethoxymethane, the derivative of formaldehyde, was then directly analyzed by GC-FID. Despite the simplicity of the developed method, however, it is characterized by its specificity, accuracy, and precision. The limits of detection and quantification of formaldehyde in the samples were of 2.44 and 8.12 µg/g, respectively. This method is characterized by using simple and economic GC-FID technique instead of MS detection, and it is successfully used to analyze formaldehyde in commonly used pharmaceutical excipients. PMID:29686930

  16. Multi-drug UPLC-MS/MS method to quantify antimicrobials in feedingstuffs at carry-over level.

    PubMed

    Civitareale, C; Mestria, S; Gallo, P; Giannetti, L; Neri, B; Stacchini, P; Fiori, M

    2018-06-25

    Carry-over is an undesirable contamination from medicated to non-medicated feedingstuffs during feedingstuffs production. In 2009, the European Commission recognised this phenomenon as unavoidable and set tolerable levels of coccidiostats and histomonostats as a result of carry-over in feedingstuffs intended for non-target animal species. Cross-contamination can also take place from other pharmaceuticals employed in medicated feed. No harmonized approach has been adopted by the Member States so far to evaluate non-target feedingstuffs containing veterinary drugs due to carry-over. However, the European Council and the Parliament are drafting a new regulation, fixing tolerable levels of drugs in non-target feedingstuffs. This work presents a simple and fast multi-drug method by liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the detection, confirmation and quantification of thirty-seven drugs belonging to different classes of antimicrobials (sulphonamides, tetracyclines, macrolides, quinolones, pleuromutilins and streptogramins) in feedingstuffs. The method was in-house validated at carry-over levels, in the concentration range 0.25-2.0 mg kg -1 , according to the Regulation (UE) 2017/625 requirements and to Commission Decision 2002/657/EC. The capability of the method to detect all drugs at lower levels than the lowest proposed by the last draft of the perspective regulation guarantees its applicability for confirmatory purposes in official control activities. The developed method has been applied to non-compliant feed samples. This article is protected by copyright. All rights reserved.

  17. Determination of Ochratoxin A in wine by packed in-tube solid phase microextraction followed by high performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Andrade, Mariane A; Lanças, Fernando M

    2017-04-14

    Ochratoxin A (OTA), a widely studied mycotoxin, can be found in a variety of food matrices. As its concentration in food is generally low (in the order of μg kg -1 ), sample preparation techniques are necessary for the analyte purification and pre-concentration in order to achieve the required low detection limits. The separation and detection methods used for OTA analysis should also offer proper sensitivity in order to allow the adequate quantification of the analyte. This manuscript addresses the development of a methodology aiming the analysis of OTA in wine samples by packed in-tube SPME in flow through extraction mode coupled to HPLC-MS/MS. The in-tube SPME set up utilized a PEEK tube packed with C18 particles as the extraction column. The method was optimized by a central composite design 2 2 +3 extra central points, having as factors the percentage of ACN and time in the sample load step. The functionalities of the method were attested and its analytical conditions, enhanced by using 22% of ACN and 6min in the sample load step. Validation of the method was also accomplished prior to analyses of both dry red wine and dry white wine samples. The method demonstrated proper sensitivity, with detection and quantification limits equal to 0.02 and 0.05μgL -1 , respectively. Linearity and precision exhibited a 0.996 correlation coefficient and RSD under 6%, respectively. The method proved to be accurate at medium and higher concentration levels with a maximum recovery of 73% at higher concentration levels. OTA was not detected in either dry red and dry white wine samples evaluated in this work. If present, it would be at concentrations lower than the detection and quantification limits established for the proposed method, and considered not a potential danger to human health according to our present knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Roka Listeria detection method using transcription mediated amplification to detect Listeria species in select foods and surfaces. Performance Tested Method(SM) 011201.

    PubMed

    Hua, Yang; Kaplan, Shannon; Reshatoff, Michael; Hu, Ernie; Zukowski, Alexis; Schweis, Franz; Gin, Cristal; Maroni, Brett; Becker, Michael; Wisniewski, Michele

    2012-01-01

    The Roka Listeria Detection Assay was compared to the reference culture methods for nine select foods and three select surfaces. The Roka method used Half-Fraser Broth for enrichment at 35 +/- 2 degrees C for 24-28 h. Comparison of Roka's method to reference methods requires an unpaired approach. Each method had a total of 545 samples inoculated with a Listeria strain. Each food and surface was inoculated with a different strain of Listeria at two different levels per method. For the dairy products (Brie cheese, whole milk, and ice cream), our method was compared to AOAC Official Method(SM) 993.12. For the ready-to-eat meats (deli chicken, cured ham, chicken salad, and hot dogs) and environmental surfaces (sealed concrete, stainless steel, and plastic), these samples were compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) method MLG 8.07. Cold-smoked salmon and romaine lettuce were compared to the U.S. Food and Drug Administration/Bacteriological Analytical Manual, Chapter 10 (FDA/BAM) method. Roka's method had 358 positives out of 545 total inoculated samples compared to 332 positive for the reference methods. Overall the probability of detection analysis of the results showed better or equivalent performance compared to the reference methods.

  19. Unconstrained Respiration Measurement and Respiratory Arrest Detection Method by Dynamic Threshold in Transferring Patients by Stretchers

    NASA Astrophysics Data System (ADS)

    Kurihara, Yosuke; Watanabe, Kajiro; Kobayashi, Kazuyuki; Tanaka, Hiroshi

    General anesthesia used for surgical operations may cause unstable conditions of the patients after the operations, which could lead to respiratory arrests. Under such circumstances, nurses could fail in finding the change of the conditions, and other malpractices could also occur. It is highly possible that such malpractices may occur while transferring a patient from ICU to the room using a stretcher. Monitoring the change in the blood oxygen saturation concentration and other vital signs to detect a respiratory arrest is not easy when transferring a patient on a stretcher. Here we present several noise reduction system and algorithm to detect respiratory arrests in transferring a patient, based on the unconstrained air pressure method that the authors presented previously. As the result, when the acceleration level of the stretcher noise was 0.5G, the respiratory arrest detection ratio using this novel method was 65%, while that with the conventional method was 0%.

  20. A Homogeneous Time-Resolved Fluorescence Immunoassay Method for the Measurement of Compound W

    PubMed Central

    Huang, Biao; Yu, Huixin; Bao, Jiandong; Zhang, Manda; Green, William L; Wu, Sing-Yung

    2018-01-01

    Objective: Using compound W (a 3,3′-diiodothyronine sulfate [T2S] immuno-crossreactive material)-specific polyclonal antibodies and homogeneous time-resolved fluorescence immunoassay assay techniques (AlphaLISA) to establish an indirect competitive compound W (ICW) quantitative detection method. Method: Photosensitive particles (donor beads) coated with compound W or T2S and rabbit anti-W antibody were incubated with biotinylated goat anti-rabbit antibody. This constitutes a detection system with streptavidin-coated acceptor particle. We have optimized the test conditions and evaluated the detection performance. Results: The sensitivity of the method was 5 pg/mL, and the detection range was 5 to 10 000 pg/mL. The intra-assay coefficient of variation averages <10% with stable reproducibility. Conclusions: The ICW-AlphaLISA shows good stability and high sensitivity and can measure a wide range of compound W levels in extracts of maternal serum samples. This may have clinical application to screen congenital hypothyroidism in utero. PMID:29449777

Top